Loading...
HomeMy WebLinkAbout8000 Wheat Stone Dr)ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 ! - DRAWING INDEX ARCHITECTURAL SHEET NO. I SHEET NAME A000 ARCHITECTURAL NOTES A110 1st LEVEL FLOOR PLAN A200 ELEVATIONS A400 WALL SECTIONS A500 DETAILS A501 IDETAILS A502 I DETAILS - IF APPLICABLE STRUCTURAL SHEET NO. I SHEET NAME ST-1 STRUCTURAL SPECIFICATIONS ST-2 FOUNDATION PLAN ST-2D FOUNDATION DETAILS ST-3 1st LEVEL STRUCTURAL PLAN ST-3A 1st LEVEL FRAMING PLAN ST-5 TYPICAL WALL SECTIONS STD I SECTIONS AND DETAILS DR HORTON A4CB CLIFTON Abbott Park, ELECTRICAL SHEET NO. ISHEET NAME E100 11st LEVEL ELECTRICAL PLAN ELEVATION B LOT 008=01 ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING �170DE, NATIONAL ELECTRIC "ODE. AND THE CITY OF ZEPHYR HILLS ORDINANCES V '_06,-021 R VILA,TE CITY CAI✓ �E HI PLAN EXAMINER BUILDING CODE SUMMARY THE PROJECT SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES FL BUILDING CODE - RESIDENTIAL: 2020 FL BUILDING CODE - FUEL GAS: 2020 FL BUILDING CODE - PLUMBING: 2020 NATIONAL ELECTRIC CODE: 2017 FL BUILDING CODE - MECHANICAL: 2020 FL FIRE PREVENTION CODE: 2020 FL BUILDING CODE - ENERGY CONSERVATION: 2020 OCCUPANCY CLASSIFICATION: RESIDENTIAL CONSTRUCTION TYPE: VB WIND ZONE: SEE ST-1 SPRINKLED: NO ZONING CODE: PROPOSED STRUCTURE COMPLIES WITH THE REQUIREMENTS OF CHAPTER 656, ZONING CODE FOR RESIDENTIAL DISTRICTS. INCL MAX BLDG HGT OF 35' AREAS CONDITIONED AREA 1 st Floor 1816 SF 1816 SF UNCONDITIONED AREA Garage 455 SF Entry 30 SF Lanai 165 SF _ 650 SF Grand total 2466 SF Vni [IMF 1 st Floor 16945 CF Grand total 116945 CF E', a ca. O } 0 0 AREA N � CD ca N J U_ w J tds Q J 5; true design studios > z O U) U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211CA O' o �. O w � c c3; rn cn 01HOMON"' J � � m o w �. .y C� U z w CD w IY O O O ti u7 z O O Cn z LLJ U) U) IlIIImm W z LL z W m w w W z > o W LLI W w 0 (m) W W O J X L.L L O 0 Q 0 w w O F— IZ z O U w olf Abbott Park O U J U) U_ LOT 008-01 0 Q w U Q z_ z U) O PROJECT NO: LLJ -1 2021.003451 O L- z DRAWN O U LDG o w CHKD: U*) JAC x w w d J � U Q m z 0 z O w U) Q z z (� Q O 04-10-2019 p I= w U REVISIONS: U_ - - - m Q No. Description Date w U) J �Q — cUn o O z U w l— x w 0000 Q :)ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 ELECTRICAL RISER DIAGRAM OPTIONAL OVERHEAD SERVICE SAME AS UNDERGROUND 150 OR 200 AMP SERVICE METER MAIN DISC. 150 OR r 200 AMP Footer Re -Bar (sized according to ° foundation plan) ° #4 awg CU bare w/ 10' stubbed ° outside of slab at service o location. Connect to footer steel w/ (2) ground clamps 5' apart UFER GROUND DETAIL N.T.S. 150 = #1 Copper or 2/ 0 Aluminum 200 = 2 /0 Copper or 4 /0 Aluminum in 2" Conduit. — A/C DISCONNECT #12 COPPER TO APPLIANCES AND GFI TYPICAL ELECTRICAL #14 COPPER TO LIGHTS AND OUTLETS PANEL #10 COPPER TO WATER HEATER UNDGND #8 COPPER TO RANGE SERV. BY POWER CO. #6 COPPER TO HVAC N.T.S. #4 GROUNDING WIRE WITH CODE APPROVED CLAMP TO EITHER: A) APPROVED GROUNDING ROD WITH MINIMUM 8' DEPTH B) BONDED TO CONTINUOUS FOOTING STEEL INTERSYSTEM BONDING TERMINATION PER NEC 250.94 NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY GENERAL ELECTRICAL NOTES ALL ELECTRICAL DESIGN AND WORK SHALL BE /N STRICT COMPLIANCE WITH THE 2017 NATIONAL ELECTRIC CODE • PER NEC SECTION 210.12 (B) ALL 15A & 20A, 120V BRANCH CIRCUITS SUPPLYING OUTLETS REQUIRE AFCI PROTECTION • CARBON MONOXIDE PROTECTION PER FLORIDA STATUTES 553.885 (2). TO BE INSTALLED WITHIN 10' OF EVERY SLEEPING ROOM • ALL OUTLETS SHOULD BE AFCI PER NEC - U.N.O. • PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V RECEPTACLES INSTALLED OUTDOORS MUST BE GFCI-PROTECTED • PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V RECEPTACLES INSTALLED WITHIN 6' OF SINK (IN NON -DWELLING OCCUPANCIES-i.e. OUTDOOR SUMMER KITCHENS RECEPTACLES) MUST BE GFCI-PROTECTED • PER NEC SECTION 406.8(8)(1) 15A & 20A RECEPTACLES IN A WET LOCATION MUST BE WITHIN AN ENCLOSURE THAT IS WEATHERPROOF WHEN AN ATTACHMENT IS PLUGGED IN AN ALL NON -LOCKING RECEPTACLES SHALL BE LISTED AS WEATHER RESISTANT • PER NEC SECTION 406.11 IN DWELLING UNITS, ALL 15A & 20A, 15V RECEPTACLES SHALL BE LISTED AS TAMPER -RESISTANT • PER NEC SECTION 800.156 NO LESS THAN ONE COMMUNICATION OUTLET SHALL BE INSTALLED WITHIN EACH DWELLING UNIT • PER NEC SECTION R314.3 AND R315.1 SMOKE DETECTORS TO BE INSTALLED INSIDE EACH SLEEPING AREA • ALL SMOKE ALARMS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 217, PER FBC 314.1. GC TO INSTALL; KIDDE MODEL # 14618A SMOKE ALARM, OR APPROVED EQUAL • PROVIDE GAS DROPS AS PER COMMUNITY ONLY • JUNCTION BOX AT WATER HEATER, RANGE AND/OR DRYER TO BE 220V IN NON GAS COMMUNITIES, AND 110V IN COMMUNITIES THAT HAVE GAS OPTIONS PROVIDE APPROPRIATE RECEPTACLE PER APPLIANCE • ALL LAMPS SHALL BE HIGH -EFFICACY TO COMPLY WITH FBC-EC R404.1 - (LOW -VOLTAGE LAMPS EXCLUDED). • PER FBC-R M1305.1 A LEVEL WORKING SPACE NOT LESS THAN 30" DEEP AND 30" WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE OF ANY APPLIANCE ABBREVIATIONS LEGEND ABV ABOVE AC AIR CONDITIONER AFF ABOVE FINISHED FLOOR AHU AIR HANDLER UNIT BLK BLOCK CABS CABINETS CLG CEILING CHR CHAIR RAIL COFF COFFERED COL COLUMN COND CONDENSER CRN CROWN MOULDING CVAC CENTRAL VACUUM SYSTEM DBL DOUBLE DIAG DIAGONAL DR DOOR DRY DRYER DW DISHWASHER EB EYEBROW FL FLOOR LINE (MAT. CHANGE) FLR FLOOR FP FIREPLACE FXD FIXED FXT FIXTURE GLS GLASS HB HOSE BIB KS KNEE SPACE LAV LAVATORY LT LAUNDRY TUB MRBL MARBLE MC MEDICINE CABINET MIR MIRROR MTL METAL OH OVERHEAD OPNG OPENING OPT OPTIONAL R & S CLOTHES ROD and SHELF REF REFRIGERATOR SD SOAP DISH SDLTS SIDE LIGHTS SGD SLIDING GLASS DOOR SH (2) SHELVES (QUANTITY) SHWR SHOWER TB TOWEL BAR TPH TOILET PAPER HOLDER T&S TUB and SHOWER TEMP TEMPERED TR TRANSOM VOL VOLUME WC WATER CLOSET WD WOOD WH WATER HEATER WNCT WAINSCOT WS WATER SOFTENER WASH WASHER ROOF NOTES • INSTALL ROOF VENTING PER MFR WRITTEN INSTRUCTIONS PER FBC R806 • ALL OVERHANG DIMENSIONS ARE TO EDGE OF RAFTER. REFERENCE WALL SECTIONS/DETAILS FOR ALL OVERHANGS NOT DIMENSIONED. • ALL UNDERLAYMENT MUST BE INSTALLED IN COMPLIANCE WITH FBC R905.1.1 • EACH 4' OFF RIDGE VENT REQUIRES (1) 46" x 3" CUT OUT IN ROOF SHEATHING PER MFR WRITTEN INSTRUCTIONS ROOF VENT CALCULATION FORMULA: 1 SQUARE INCH VENT FOR EVERY 300 SQUARE INCHES OF CEILING *144 SQ. IN. = 1 SQ. FT. BLDG. CEILING (SF) x 144 = BLDG (SQ. IN.) BLDG. (SQ. IN.) 1300 = SQ. IN. OF VENT REQUIRED SQ. IN. OF VENT REQUIRED 12 = 50% AT HIGH AND 50% AT LOW. PER FBC SECTION R806.2: 40% MIN, BUT NOT MORE THAN 50% OF VENTILATION MUST BE PROVIDED BY VENTILATORS LOCATED NO MORE THAN T-0" BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE BASIS OF CALCULATION: ("OR EQUAL" ACCEPTABLE) (a) OFF RIDGE VENTS - STAMPCO W/ 36 SQ IN (NFVA) PER LINEAL FT (b) SOFFIT VENTS - GP T3-1/3" FULL VENT PERFORATED W/ 9.19 SQ IN (NFVA) PER LINEAL FT CALCULATED LINEAL FOOT OF SOFFIT VENT SHALL NOT INCLUDE NON -VENTED FIRE RATED SOFFIT LOCATED LESS THAN 5' FROM PROPERTY LINE EXTERIOR ELEVATION GENERAL NOTES • FRONT ELEVATIONS BANDING, MOLDING, COLUMNS AND TRIM SHALL RECEIVE A SAND FINISH. SEE ELEVATION FOR DEPTH OR RAISED BANDING • SIDE AND REAR ELEVATIONS BANDING AROUND WINDOWS AND DOORS MAY BE OPTIONAL PER COMMUNITY SPECS - SEE COMMUNITY SPECIFICATIONS OR CONSULT THE CONSTRUCTION MANAGER. ALL BANDING SHALL RECEIVE A SAND FINISH • ROOF COVERING SEE COMMUNITY SPECIFICATIONS OR CONSULT THE CONSTRUCTION MANAGER. SEE STRUCTURAL SHEETS FOR SHEATHING REQUIREMENTS • FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND AROUND ROOF OPENINGS • WINDOW PAN FLASHING SHALL BE IN ACCORDANCE WITH FBC R703.4 • WALL HEIGHTS VERIFY ALL BEARING WALL HEIGHTS WITH FINAL TRUSS LAYOUTS • LATH PER FBC R703.7.1, LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 11/2-INCH-LONG (38 MM), 11 GAGE NAILS HAVING A 7/16-INCH (11.1 MM) HEAD, OR 7/8-INCHLONG (22.2 MM), 16 GAGE STAPLES, SPACED NOT MORE THAN 6 INCHES (152 MM), OR AS OTHERWISE APPROVED • PLASTER PER R703.7.2, PLASTERING WITH PORTLAND CEMENT PLASTER SHALL BE NOT LESS THAN THREE COATS WHERE APPLIED OVER METAL LATH OR WIRE LATH AND SHALL BE NOT LESS THAN TWO COATS WHERE APPLIED OVER MASONRY, CONCRETE, PRESSURE -PRESERVATIVE TREATED WOOD OR DECAY -RESISTANT WOOD AS SPECIFIED IN SECTION R317.1 OR GYPSUM BACKING. IF THE PLASTER SURFACE IS COMPLETELY COVERED BY VENEER OR OTHER FACING MATERIAL OR IS COMPLETELY CONCEALED, PLASTER APPLICATION NEED BE ONLY TWO COATS, PROVIDED THE TOTAL THICKNESS IS AS SET FORTH IN TABLE R702.1(1). ON WOOD -FRAME CONSTRUCTION WITH AN ON -GRADE FLOOR SLAB SYSTEM, EXTERIOR PLASTER SHALL BE APPLIED TO COVER, BUT NOT EXTEND BELOW, LATH, PAPER AND SCREED. THE PROPORTION OF AGGREGATE TO CEMENTITIOUS MATERIALS SHALL BE AS SET FORTH IN TABLE R702.1(3) • WEEP SCREED PER R703.7.2.1 A MINIMUM 0.019-INCH (0.5 MM) (NO. 26 GALVANIZED SHEET GAGE), CORROSION -RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED, WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 31/2 INCHES (89 MM) SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C926. THE WEEP SCREED SHALL BE PLACED NOT LESS THAN 4 INCHES (102 MM) ABOVE THE EARTH OR 2 INCHES (51 MM) ABOVE PAVED AREAS AND SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WEATHER -RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED • WATER -RESISTIVE BARRIERS PER R703.7.3, WATER -RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE BARRIER IS DIRECTED BETWEEN THE LAYERS GENERAL NOTES • ALL CONSTRUCTION SHALL MEET THE LATEST EDITION OF CODES ADOPTED BY THE LOCAL GOVERNING AGENCIES • PER FBC R302.5 NO OPENINGS FROM A PRIVATE GARAGE ARE PERMITTED DIRECTLY INTO SLEEPING AREAS. ALL OPENINGS SHALL HAVE SOLID WOOD, INSULATED STEEL OR 20 MIN. FIRE RATED DOORS NOT LESS THAN 1-3/8 INCHES THICKNESS, EQUIPPED WITH A SELF CLOSING DEVICE. ALL DUCTS IN THE GARAGE OR PENETRATING THE WALL OR CEILING SEPARATING THE GARAGE AND DWELLING SHALL BE CONSTRUCTED OF MIN. 26 GA. SHEET METAL, 1 INCH MINIMUM RIGID CLASS 0 OR 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE • PER FBC TABLE R-302.6 GARAGE SHALL BE SEPARATED FROM RESIDENCE AND IT'S ATTIC W/ MIN. 1/2" GYP BOARD ATTACHED IN ACCORDANCE WITH TABLE R702.3.5. HABITABLE ROOMS SHALL BE SEPARATED FROM ROOM ABOVE W/ MIN 5/8" TYPE "X" GYP BOARD, WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY. ANY STRUCTURE SUPPORTING THE ASSEMBLY SHALL BE PROTECTED W/ MIN 1/2" GYP BOARD • PER FBC R-312.1 PORCHES, BALCONIES OR RAISED FLOOR SURFACES LOCATED MORE THAN 30" ABOVE FINISHED FLOOR OR GRADE SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. PER FBC R-312.1.2 OPEN SIDES OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" ABOVE FINISHED FLOOR OR GRADE SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS • PER FBC R-312.1.3 REQUIRED GUARDS ON OPEN SIDES OF STAIRWAYS, RAISED FLOOR AREAS, BALCONIES AND PORCHES SHALL HAVE INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES WHICH DO NOT ALLOW PASSAGE OF A SPHERE 4" OR MORE IN DIAMETER • PER FBC R-308.4.5 GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR FACING HOT TUBS, SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR SWIMMING POOLS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE, SHALL BE CONSIDERED A HAZARDOUS LOCATION. G.C. TO VERIFY IF HOMEOWNER SELECTS ANY OF THESE ITEMS LISTED. IF ANY OF THESE ITEMS LISTED IS INSTALLED, SUCH GLAZING FACING THOSE ITEMS IS TO BE TEMPERED • PER FBC R312.2, PROVIDE WINDOW FALL PROTECTION IN ACCORDANCE WITH R312.2.1 AND R312.2.2 • GAS OPT. PER COMMUNITY. VERIFY WITH BLDR • C.J. = RECOMMENDED MASONRY CONTROL JOINT LOCATION • ALL FINISHES, MATERIALS, HOUSEWRAP, WINDOW AND DOOR FLASHING, TAPING AND SEALANTS TO BE INSTALLED PER BUILDER PROVIDED SPECIFICATIONS OR MFR WRITTEN INSTRUCTIONS • ALL FINISH DETAILS & TYPICAL PLAN NOTES PROVIDED BY BUILDER IN ACCORDANCE WITH TYPICAL BUILDER SPECIFICATIONS • REFER TO STRUCTURAL ENGINEERING DRAWINGS FOR ALL EXTERIOR WALL STUD SPECIES, SIZES AND SPACING 0 U 0 o0 " L0 0 APEX W U (U Q% O 1 {tj N N co J ILL. W J tds �i J true design studios a)a) Z O U U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 p o O W 0,11H09ON' Cn _>J m W Q � C1 } N Z W 0 W IY O 0 O O ti u7 Z ti Z O w W Imm 00 W W0. W _Z LL W Z W IJ O cn m W w V Q Z_ Z > Q Q Z W W o W O ct J LL L �— O ZO Q 0 (r w O F- 11 Z O a U w p w Abbott Park Q O U J (n LL LOT 008-01 0 Q — W H U Q Z_ Z C� U) O PROJECT NO: w J 2021.003451 O w Z DRAWN: O U LDG o w CHKD: JAC x w w 0_ _l � U Q m Z 0 W Q Z O LU U) Q z U) Q�Q O 04-10-2019 Q F- w U REVISIONS: U_ � Q No. Description Date W (n J Q � U C� U) O o O Z U w I- X W AOOO Q )ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 CO a) M 6 65'-0" 60'-0" 9 6_0" 17'-10" 6 4" 5'-4" T-6" 23'-0" - 1'-4" 1,-4„ b VERIFY AC COND ti LOCATION W/ SURVEY w - w = N BEDROOM 1 -- � o = 9'-4" CLG N o 6-0" 8'4" M N 21068 LAUNDRY 9'-4" CLG I_M— WIC 9'-4" CLG 147 146 1S&1R 1 I I I II 0 I I c� I I o ii I I OUTDOOR LIVING 9'-4" CLG I I � I I � II N= I I Ln - 0 0 0 I I m ' cV po I I I I N I I zn 180 -------------- 1st LEVEL FLOOR PLAN 1/4" = V-0" WHEN PRINTED ON 22"x34" 27'-0" I 3010 FX TEMP 8' - 0" H.H. 9'-4" CLG i'''; 120 101 "X )IN4 106 20 125 BATH 1 -� ' 9'-4" CLG T-0" '-2" 2068 I I8 I O° I I %D 1%1 �i O O NN —6 21068 O 144 N 0? N % KITCHEN ' 9'-4" CLG m 130 142 1 11 101 108 a w F- 0 N 0 00 DINING ROOM 9'-4" CLG 33'-0" PANTR FOYER 9114" C' - GARAGE 9'-4" CLG M. 2'-0" 1 ao N I 1-d ------ LA �clj \�10 00011101000 j, ,jotEzl i ------ ' — 'PAP 1 rffi,' S-6" 4,41' iv 6-0" 2'-0" ot N - 110 - - ----15&1R.-- - - 0 2-2068 Ln V) T-10" I cc DJ (U a = T-8 1 /2" W = o i j V) 00 BEDROOM 2 I Ln o 9'-4" CLG i N cV ti FLOOR PLAN KEY NOTES (SEE SHEETA000 FOR GENERAL NOTES) 100 - PROVIDE FURRING AS NEEDED 101 - 2x6 WALL 102 - DOUBLE WALL (2-2x4 U.N.O.) 103 - 42" HIGH HALF WALL WITH CAP 104 - DOOR HEIGHT DIFFERS (RE: COMMUNITY/BLDR SPECS) 105 - INTERIOR FLAT HEADER at 8' U.N.O. (SEE PLANS FOR WIDTH) 106 - INTERIOR ARCHED HEADER (from 7'4" to 8') (SEE PLANS FOR WIDTH) 107 - SHOWER NICHE 14" x 18" w/BOTTOM at 4'-10" AFF, SHOWER CONTROLS POSITIONED BELOW NICHE 108 - EXTEND 36" H COUNTER 16" OVER 2x6 WALL BELOW 109 - 36" HIGH HANDRAIL 110 - SELF CLOSE DOOR IS 1 3/8" MIN SOLID CORE -OR- 20 MIN FIRE RATED 111 - ATTIC ACCESS - SIZE AS NOTED 20 MIN FIRE RATED 112 - INTERIOR FLAT HEADER at 8-8"' U.N.O. (SEE PLANS FOR WIDTH) 120 - RECESSED TILE SHOWER - SIZE AS NOTED 121 - TILE SHOWER WITH CURB - SIZE AS NOTED 122 - VIKRELL BASE SHOWER - SIZE AS NOTED 123 - TUB R.O. 5'-0 %' 124 - GARDEN TUB - SIZE AS NOTED 125 - TEMPERED GLASS SHOWER ENCLOSURE 126 - TEMPERED GLASS SHOWER ENCLOSURE ON 42" H 1/2 WALL w/SLP TOP 127 - SHOWER SEAT AT 18"x18"x20" 128 - SHOWER BENCH 129 - LAUNDRY SINK 130 - SINK 140 - OVERHEAD CABINET 141 - REFRIGERATOR - OPTIONAL 142 - DISHWASHER 143 - RANGE WITH MICRO HOOD 144 - COOKTOP 145 - DOUBLE OVEN 146 - WASHER - OPTIONAL 147 - DRYER - OPTIONAL 160 - INSTALL MECH PROTECTION PER CODE 161 - EQUIPMENT STAND LOC at 18" AFF FOR GAS WH ONLY 162 - LOUVERED DOOR 163 - METAL A/C STAND 164 - BOLLARD AS REQ. PER BUILDING CODE 180 - EXTERIOR HEADER (RE: ELEVATION) 181 -SYNTHETIC STONE VENEER L O c� O O p APEX 0 O O ca NN N c� J +, LL W _J tds Q J � true design studios > z O U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 cn O O .- cn W H 01,109ON' > Ar m W lY Q C� U } N Z W (D W O O O O r` z d' u7 O p Z W H m —/ U) 10 W Z_ J O c) m w w C.) Q w z_ 0 > 0 Q W w wQ J V W W O X LL LL z O z O Q 0 a Z O a LL Q w � J o Abbott Park v J U) Q LOT 008-01 0 U Q Z 0 PROJECT NO: w O 0 1 2021.003451 w DRAWN: O U LDG o wCHKD: U') JAC co x p. J Q U U) m z 0 Q Uj >z 0 O Cw G rUrn) V Q z z U) Q O 04-10-2019 p w U REVISIONS: ILL I­_Q No. Description Date w cn J Q O O z = Q U w f- X w A 110 Q :)ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 12 ® ® 5 1st LEVEL BRG TOB Li �J 1st LEVEL FIFE LEFT ELEVATION 1/8" = 1'-0" WHEN PRINTED ON 22"x34" ROOF VENTILATION Area HIGH LOW VENT # VENT 1 RATIO PROP HIGH LINEAL FT PROP LOW 2465 SF j 592 in2 1 592 in2 1 4 144 1 576 1 140 11286.E 5:12 le? ROOF PLAN 1/8" = V-0" WHEN PRINTED ON 22"x34" 5:12 JP Sri RIDGE 1st LEVEL BRG (TOB)_,$,_ 9'-4" 1st_LEVEL_FFE ELEVATION KEY NOTES (SEE SHEET A00o FOR GENERAL NOTES) 200 - CONCRETE TILE ROOF 201 - SHINGLE ROOF 202 - TAMKO OFF RIDGE VENT 203 - LOMANCO ROOF VENT 204 - MILLENNIUM ROOF VENT 12 5 220 - FOUNDATION WALL FINISH LINE W/STUCCO PARGE COAT 221 - CEMENT PLASTER FINISH - OVER CONCRETE MASONRY SHALL BE 1/2" THICK TEXTURED PER COMMUNITY SPECIFICATIONS SEE GENERAL NOTES A000 FOR SPECIFICATIONS 1stLEVEL BRG �— TOB -- 1st LEVEL BRG TOP � �� 222 - CEMENT PLASTER FINISH - OVER WOOD FRAMED WALLS SHALL BE 7/8" COAT) TEXTURED PER COMMUNITY ^ (3 - O SPECIFICATIONS. OVER ASPHALT IMPRE NATE PAP BACK WIRE LATH, OVER HOUSE WRAP OVER EXTERIOR 24 SHEATHINGP T PER STRUCTURAL DRAWINGS. LATH TO BE - - - - -. - - - - - - -- - FURRED OUT FROM BACKING FROM AN APPROVE - -- - METHOD IN ACCORDANCE WITH FBC R703.7 SEE GENERAL NOTES A000 FOR SPECIFICATIONS 1 LEVEL FIFE st - 1 t LEVEL FIFE S 22 3 - FIB ER CEMENT LAP SIDING 224 - FIBER CEMENT SHAKE SIDING 225 - FIBER CEMENT BOARD & BATTEN SIDING ELEVATION 226 - 227 - SYNTHETIC STONE VENEER STONE LEDGE _RIGHT 228 - BRICK VENEER 1/8" = V-0" WHEN PRINTED ON 22"x34" 1st LEVEL BRG (TOB) - -A --------- ---- - LIE] 1st LEVEL FFE REAR ELEVATION 1/8" = V-0" WHEN PRINTED ON 22"x34" 1-st LEVEL BRG (TOB------------ 9; 4" 1st LEVEL FIFE 0 --- _ 240 - EXTERIOR DOOR SIZE PER FLOOR PLAN 259 - 2"x TRIM - SIZE AS NOTED 260- CV BAND - SIZE AS NOTED - 1" PROJ U.N.O. 261 - CV BAND - SIZE AS NOTED - 2" PROJ U.N.O. 262 - 1"x TRIM - SIZE AS NOTED 263 - DECORATIVE SHUTTER - SIZE AS NOTED 264- DECORATIVE BRACKET - AS NOTED - OR EQUIVALENT 265 - DECORATIVE LOUVER - SIZE AS NOTED 266 - 4" DECORATIVE DRAIN TILES 267 - 42" HIGH RAILING IS POWDER COATED ALUMINUM, AND COLOR IS DETERMINED BY THE BUILDER'S SPECS 280 - EXTERIOR WALL MOUNTED LIGHT FIXTURE. q- OF LIGHT TO BE 6-0" A.F.F. U.N.O. BUILDING HEIGHT - -- HEIGHT ABV GRADE BUILDING HEIGHT AFF ---------- ----AFF -L--- ----------------) --------------------------------------------------------------------------------------------------------------------------- 1 T 11 7/8" 18' - 7 7/8" 17' - 11 7/8" 201 12 5 FYPON BKT11x20 264 260 4" 264 FYPON 222 222 BKT7xl2x4 4" 260 T ENTRY HEEL ----------- ---------- — 11' - 4" 4" 260 260 4" 1st LEVEL BRG LOBS 2so 6° 1st LEVEL BRG (TO --------- -- =� _------------- 18"x62" 263 - 221 a E] _ 280 4" 227 3" .TYp a ABL.i=.I~.ND) 226 N R --; L�l 1st LEVEL FIFE �- FRONT ELEVATION 1/4" = V-0" WHEN PRINTED ON 22"x34" -----------1st_LEVEL FIFE 0—_W O 0 APEX N co 0 O N N co J w tds J J true design s n studios � � o z O Y 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 0 0 w 01H09ON' co W Aw 0 co U z W (D W Of 0 O 0 rn LO ti z d' ti O O Cn Z MM w C W w W Z LL z �w/� cn O 0Y J - w w z < O z � Q w m w w (l,) w w _1 L LL L Z 0 O D_ Ilf U Q Abbott Park O J u- LOT 008-01 Q U z OPROJECT NO JO 2021.003451 DRAWN: LDG U W CHKD: ~ JAC x W Q_ x } m 0 W z O w Q z U) O 04-10-2019 H U REVISIONS: Q No. Description Date } C� O J z U w 1-- x W A200 Q i ��i.v, [r 0 w x z O 0 H Z a W w J U U) 0 w I-- Q (D U) w 0 LL 0 O L0 U) w J U U) U) _z fY U) (7 Z Q W U) w H w J Q U U) H- z O 0 )ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 INSULATION BAFFLE BETWEEN TRUSSES INSTALLED PER MFR WRITTEN SPECS CONCRETE TILE ROOFING INSTALLED PER MFR SPECS OVER WD SHTHG OVER PRE-ENG WD TRUSSES (RE: STRUCTURAL) ALUMINUM DRIP OVER 1x2 DRIP EDGE OVER 2x6 FASCIA W/ ALUMINUM WRAP VENTED SOFFIT INSTALLED PER MFR WRITTEN SPECIFICATIONS NOTE: INSTALL PORTLAND CEMENT BASE PLASTER IN ACCORDANCE WITH ASTM 926 AND ASTM C 1063 NOTE: INSTALL ALL VINYL CV ACCESSORIES PER MFR WRITTEN SPECIFICATIONS m mm INSULATION BAFFLE BETWEEN TRUSSES INSTALLED PER MFR WRITTEN SPECS FIBERGLASS SHINGLE ROOFING — INSTALLED PER MFR SPECS OVER WD SHTHG OVER PRE-ENG WD TRUSSES (RE: STRUCTURAL) ALUMINUM DRIP OVER 1x2 DRIP EDGE OVER 2x6 FASCIA W/ ALUMINUM WRAP VENTED SOFFIT INSTALLED PER MFR WRITTEN SPECIFICATIONS NOTE: INSTALL PORTLAND CEMENT BASE PLASTER IN ACCORDANCE WITH ASTM 926 AND ASTM C 1063 NOTE: INSTALL ALL VINYL CV ACCESSORIES PER MFR WRITTEN SPECIFICATIONS §8" THICK STUCCO FINISH - TEXTURED PER COMMUNITY SPECIFICATIONS STUCCO PARGE COAT GRADE (SLP AWAY FROM STRUCTURE)(TYP ALL SIDES) VARIES (RE: 'GOOF PLAN) I, VARIES (RE: 12 ELEVATION) F_ 12" MINIMUM SAG RESISTANT CEILING GYP BRD PER FBCR TABLE R702.3.5 POURED BOND BEAM (RE: STRUCTURAL) PRE CAST LINTEL (RE: STRUCTURAL) NOTE: RE: FLOOR PLAN (SH Al 10/A120) FOR WINDOW SIZE. RE: WINDOW MFR SPECS FOR CODE COMPLIANCE AND INSTALLATION DATA TYP ONE-STORY WALL SECTION SCALE: 1" = V-0" VARIES (RE: 12 ELEVATION) F VARIES (RE: �OOF PLAN) �I 1st LEVEL TOB VARIES (RE: ELEV) INSULATION PER CODE a ° a ° a 12" MINIMUM SAG RESISTANT CEILING GYP BRD PER FBCR TABLE R702.3.5 POURED BOND BEAM (RE: STRUCTURAL) PRE CAST LINTEL (RE: STRUCTURAL) NOTE: RE: FLOOR PLAN (SH Al10/A120) FOR WINDOW SIZE. RE- WINDOW MFR SPECS FOR CODE COMPLIANCE AND INSTALLATION DATA 1 /2" GYP BRD OVER ALUMINUM FOIL INSULATION W/ 1x2 TREATED FURRING STRIPS at 24" O.C. MAX 1x TREATED FURRING TYP at TOP & BOT OF BLOCK WALL MAIN FIN FLR 0'-0" rINSTALL VAPOR BARRIER IN ACCORDANCE WITH ASTM E 1643-98 I - 7�: -- FOUNDATION/FOOTING VARIES (RE: STRUCTURAL) 1 TYP ONE-STORY WALL SECTION A400 SCALE: 1 " = 1'-0" CDU N y r- 194, Jc'APEX rn 4- x N a N c? cV co ILL w d a J � J_ t S z O true design studios Y U 9000 REGENCY SQUARE BLVD. CD O SUITE 100, JACKSONVILLE, FL 32211 c: C:)vi O w 0 t0 U >• cu J 0 � 0MON m � w 1 r Q 0 m U z w Ir 0 0 0 r` v u7 r` O z U w z w W 00 m w W w z W z G w Q O U 0 O J LL w W O Of Q a w O U - Q a z � O O J 0 LL F_ Q z U z a _ r,_ 0 w O -- Q J O U z U) PROJECT NO: U ow w � Q ~ z DRAWN: IX DVO m Q CHKD: LU TSD w O m0 o LO w U) w O J w 0 Qm z O co z O F= � U U Q Z co REVISIONS: Q AV J O z U w H X 0 w co w w J w Q � U Q m A400 z O 0 )ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 WOOD SHEATHING WRB LAYER #1, STUCCO WRAP METAL LATH 7/8" THICK, 3 COAT CEMENT PLASTER LAP WRB & TAPE OVER ROOF/WALL SCREED 5"x5" "L" TYPE CONTINUOUS GALV. METAL FLASHING (NAIL TO ROOF DECK, NOT WALL SHEATHING) CAP SHINGLE - DO NOT NAIL, INSTALL WITH ROOF CEMENT r— SHINGLE ROOFING ROOF CEMENT "L" FLASHING SCALE: N.T.S. O 1. FOLD INWARD at PT. A © 1. FOLD INWARD at PT. A 2. CREASE at PT. B ® FOLD FOLD at 45°::��7 ® 1. FOLD INWARD at PT. A 2. CREASE at PT. B 3. CREASE at PT. C 4. FOLD PT. C OVER PT. B UNTIL PT. C TOUCHES BOTTOM FLANGE FELT UN SHINGLE ROOFING DRIP EDGE: OVERLAP T, EXTEND 1/2" BELOW SHEATHING, MECHANICALLY FASTEN 4" O.C. MAX BOTTOM xyx � x x x x x O1. FOLD INWARD at PT. A 2. CREASE at PT. B 3. CREASE at PT. C ® ®FOLD at 77° WATER TIGHT SEAL. FOLD, DO NOT CUT 7/8" THICK, 3 COAT CEMENT PLASTER WRB LAYER #2, FORTIFIBER BUILDING PAPER WRB LAYER #1, STUCCO WRAP LAP LAYERS OF BUILDING WRAP OVER NAILING FLANGE, STOP WRB APPROX. 1 1/2" ABOVE SHINGLES ROOF/WALL SCREED 5x5 WALL FLASHING \ 00 w�_ 0 zW � 5 x x KICK -OUT x x x FLASHING x (SEE DETAIL) y� WATER TIGHT (BEND OR SOL FASCIA WRAP NOTE: INSTALL KICKOUT FLASHING AT BOTTOM OF ROOF & WALL INTERSECTIONS BLDG PAPER OVER 'QUICK FLASH" PIPE THROUGH WAL 6" SELF ADHESIVE FLASHING (INSTALL PER MANUF. SPECS) BLDG PAPER UNDER'QUICK FLASH" VENT PENETRATION SCALE: N.T.S. CUT OPENING IN APPROVED HOUSEWI FOR BOX INSTALLATI, WRB LAYER #1, STUC WRAP WOOD SHEATHING APPROVED HOUSEWF BELOW CUT SUCH THAT NO MEMBRANE ENTERS BOX, APPLY TO FACE EDGE APPLY E-Z BEAD OVER 60 MIN GRADE 'D' FELT -PROVIDE SEALANT AT ALL JOINTS AND INTERSECTIONS STEP #1 STEP #3 STEP #5 WRB LAYER #1, STUCCO WRAP CUT "X" INTO SELF - ADHERING MEMBRANE FLASHING APPLY SELF -ADHERING MEMBRANE FLASHING OVER BOX AND OVER APPROVED WRB LAYER #1 ELECTRICAL RECEPTACLE / I + — 2x SUB-BAND\W/1/2"X? NOTCH ----------- @ END, WRAPPED IN PEEL & STICK \ 1 1 DRIP EDGE Vie" TEXTURED I 1 FINISH @ WOOD�58'\TEXTURED FINISH @CMU 1 1/8' \ I / / \ METAL FASC� WRAP\ 1" FROM STUCCOI, j FROM WOZD WALL °I j• { I EXTERIOR WALL \ OR CMU) fKAME \ \ NOTE: NOTCH FOR 2x6 SUB ROOF KICK OUT \ ONLY REMOVED FOR CLARITY \BAND \ ROOF DECK (BEYOND) OA ELEVATION PRE-ENG'D TRUSS TO BE CUT @ WALL INLET TO AVOID CONTACT W/ TEXTURED FINISH 2"x4"x4'-0" SCABBED TO TRUSS W/12d NAILS 6"-8" O.C. MAX METAL FASCIA 2x SUB -BAND W/1 �"x4" NOTCH @ ENE METAL WRAP FASCIA 2x6 SUB B) DRIP EDGE EXTERIOR WALL (FRAME OR CMU) WRB LAYER #1, STUCCO WRAP APPLY 60 MIN GRADE 'D' FELT OVER SELF - ADHERING FLASHING OVER APPROVED HOUSEWRAP WRB LAYER #2, FORTIFIBER BLDG PAPER STEP#2 STEP #4 STEP #6 SELF - ADHERING MEMBRANE FLASHING ELASTOMERIC COATING OVER STUCCO/ C.V. FINISH (SEE TYP WALL SECTION) METAL LATH SCALE: N.T.S. FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS METAL FLASHING, WRAPPED MIN 1' ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/1/2"X? NOTH @ END, WRAPPED IN PEEL & STICK `ROOF CEMENT @ ROOF EDGE OMITTED FOR SUB BAND DETAIL (a)- WALL CLARITY WALL KICK -OUT FLASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS METAL FLASHING, WRAPPED MIN 'q" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/1/2"x? NOTH @ END, WRAPPED IN PEEL & STICK 'ROOF CEMENT @ ROOF EDGE OMITTED FOR CLARITY AIL Cad WALL W/ KICK -OUT WALL KICKOUT FLASHING SUB BAND DETAIL a@ WALL SCALE: N.T.S. SCALE: N.T.S. O N cy � O APEX' O V', O �I, N cu:: N co J LIL �.. W Q Jtds Z -Q 0 true design studios Y U 9000 REGENCY SQUARE BLVD. ay o SUITE 100, JACKSONVILLE, FL 32211 c:' O may', O' W'. cf) 010HOMO5N, co U) Q' 1✓', U Z W d) W w O O O O ti LID 10, U) W Z W U) Z) m L.L W W Z ♦W U) Z C G w Q 0 0 Q O J w L- W o < 0 w O U = X U � Z LIL LU O -- J Q J O U Z UPROJECT NO: 0 W W Q ~ Z DRAWN: 0 IX DVO - to Q CHKD: Q TSD ILL O \ m 0 LO U) >W W O J a W U 2 U) Z (� U) Z O 9 _U LL 0 Z >- REVISIONS: Q W U) W 2 H W J W Q 0U - Q H A500 Z 0 0 DocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 1/2" (MIN) STL FINISH TEXTI PER COMMUI SPECIFCATIC FLANGE CASI BEAD CASING BEAD at WN SCALE: N.T.S. 5/8" CEMENT PLASTER 12" WIDE SELF-ADHESIVE FLASHING CENTERED UNDER CONTROL JOINT (CLEAN MASONRY BEFORE APPLYING) PRE -FORMED CONTROL JOINT W/ STRIP LATH CONTROL JOINT - HORIZ - CMU SCALE: N.T.S. VINYL ANGLED CASING BEAD (AM66-ANGLED-1250) VINYL CASING BEAD (AM66-1250) 1/2" (MIN) TEXTURED FINISH at MASONRY RAISED BAND at BLOCK SCALE: N.T.S. tie' GYP BRD OVER J PRE -SHAPED STUCCO BAND 1x2 TREATED 7.W/ SLP TOP INSTALLED PER FURRING STRIPS MFR WRITTEN SPECS (RE: at CMU WALL (TYP) ELEV) SELF ADHESIVE -OR- FLUID APPLIED FLASHING (CLEAN MASONRY BEFORE APPLYING) PT I WOOD BUCK VINYL FLANGE CASING BEAD SHIM AS NEEDED INSTALLED PER MFR WRITTEN SPECS (TYP) 48' BACKER ROD W/ SEALANT INTERIOR EXTERIOR WINDOW HEAD at CMU SCALE: 1 ti2" = 1'4" PRE -FORMED CONTROL / \ JOINT W/ STRIP LATH 5/8" CEMENT PLASTER 12" WIDE SELF-ADHESIVE FLASHING CENTERED UNDER CONTROL JOINT (CLEAN MASONRY BEFORE APPLYING) CONTROL JOINT - VERTICAL - CMU SCALE: N.T.S. CORNER BEAD (FASTENER & SPACING at 7 0.C.) ;MU 1/2" (MIN) STUCCO FINISH TEXTURED PER COMMUNITY 3PECIFCATIONS CORNER BEAD at BLOCK SCALE: N.T.S. CMU WALL W/ 48' STUCCO FINISH (RE: STRUCTURAL) GYP BRD OVER PRE -SHAPED STUCCO BAND 1x2 TREATED W/ INSTALLED PER MFR FURRING STRIPSLj WRITTEN SPECS (RE: ELEV) at CMU WALL (TYP) WOOD BLOCKIN SELF ADHESIVE -OR- FLUID APPLIED FLASHING (CLEAN MASONRY BEFORE APPLYING) PT 1x WOOD BUCK VINYL FLANGE CASING BEAD SHIM AS NEEDED INSTALLED PER MFR WRITTEN SPECS (TYP) 48' BACKER ROD W/ SEALANT INTERIOR EXTERIOR WINDOW JAMB at CMU SCALE: 1 y2" = V-0" 6" SELF -ADHERING FLASHING WEATHER RESISTIVE BARRIER #1 WEATHER RESISTIVE BARRIER #2 6" SELF -ADHERING FLASHING GALV'D MI "Z" FLASI DO NOT CP.—,... SEAL OPENING 1 1/4" X 6" SIMULATED WOOD TRIM MEMBER SEAL GAP W/ CAULKING OR APPROVED SEALANT STUCCO CASING BEAD STUCCO FINISH 6" SELF ADHESIVE OVER TOP & SIDES SELF FLASHING UNIT PREMANUF. DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT at TOP & SIDES DRYER VENT (BLOCK) SCALE: N.T.S. <\Q v SIDING TO STUCCO FRAME TO BLOCK SELF ADHESIVE -OR- FLUID APPLIED PAN FLASHING (CLEAN MASONRY BEFORE APPLYING) EXTEND UP AT JAMBS (4" MIN) PRECAST CONCRETE SILL 48' BACKER ROD W/ SEALANT VINYL FLANGE CASING BEAD GYP BRD OVER INSTALLED PER MFR 1x2 TREATED WRITTEN SPECS (TYP) FURRING STRIPS CMU STEMWALL W/ at CMU WALL (TYP) §8" STUCCO FINISH (RE: STRUCTURAL) INTERIOR EXTERIOR WINDOW SILL at CMU SCALE: 1 y2" = V-0" ELECTRIC ME" FIELD VERIFY LOCATION AREA TO RECL. STUCCO SCRATCH COAT & 1 COAT OF PAINT W/ BACK -ROLL PRIOR TO ELECTRIC METER INSTALLATION ELECTRICAL CONDUIT PENETRATION WOOD CONST BEYOND WOOD SHEATHING WEATHER RESISTIVE BARRIER #1 WEATHER RESISTIVE BARRIER #2 5/16" X 7 1/4" LAP SIDING W/ 6 REVEAL STARTER STRIP DO NOT CAULK OR SEAL OPENING GALV'D METAL'Z" FLASHING 1 1/4" X 6" SIMULATED WOOD TRIM MEMBER STUCCO CASING BEAD SCALE: N.T.S. GYP BRD OVER 1x2 TREATED FURRING STRIPS at CMU WALL (TYP) PT 1x4 PT 2x4 FRAME ANCHOR SHIM AS NEEDED INTERIOR WD SHE (RE: STF INISH COATING OVER PRIMED HREE COAT STUCCO FINISH 8" NOM) OVER GALV MTL LATH �/ER 15# FELT OVER APPROVED DUSEWRAP ASTEN TO WD STRUCTURAL IEMBER at 7" O.C. MAX "TO fie" MID -WALL JEEP SCREED N J " WIDE STRIP SELF ADHESIVE LASHING, CLEAN MASONRY IEFORE APPLYING /2" (MIN) STUCCO FINISH EXTURED PER COMMUNITY ;PECIFCATIONS STUCCO DNE (1) 3 ELECTRIC CAVITY TO BE FILLED WITH RIGID POLYMERIC ISOCYANOTE-POLYBLEN FOAM ("GREAT STUFF" OR SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEC WIRE PENETRATES PROVIDE STUCCO SCRATCH COAT LARGER THAN THE ELECTRIC METER CAN OR METER CAN COMBO OR METER CAN AND DISCONNECT SCALE: N.T.S. FIBERCEMENT -OR- VINYL LAP SIDING OVER APPROVED HOUSEWRAP INSTALLED PER MFR WRITTEN SPECIFICATIONS EXTEND HOUSEWRAP OVER NAILING FLANGE WD SHEATHING I r---4L- (RE: STRUCT) - MTL DRIP FLASHING W/ HEMMED EDGE SET IN CONT BEAD OF SEALANT F TRIM (RE: ELEVATION) -- EXTEND 12" SELF -ADHERING MEMBRANE FLASHING OVER WINDOW FLANGE SET IN CONT BEAD OF SEALANT ---� : VINYL FLANGE CASING BEAD INSTALLED PER MFR WRITTEN SPECS (TYP) 1/2" (MIN) STUCCO FINISH TEXTURED PER COMMUNITY A SPECIFCATIONS SIDING HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOCK) SCALE: N.T.S. DOOR HEAD at CMU CMU LINTEL (RE: STRUCTURAL) CONTINUOUS BEAD OF SEALANT SELF ADHESIVE -OR FLUID APPLIED FLASHING (CLEAN gMpApS�OyNNRGY�BEFORE METALI DOOR FRAME EXTERIOR SCALE: 1 1/2" = 1'-0" GYP BRD OVER 1x2 TREATED FURRING STRIPS at CMU WALL (TYP) PT 1x4 PT 2x4 FRAME — ANCHOR SHIM AS NEEDED INTERIOR DOOR JAMB at CMU CMU WALL W/ 1/2" (MIN) STUCCO FINISH (RE: STRUCTURAL) CONTINUOUS BEAD OF SEALANT SELF ADHESIVE -OR- FLUID APPLIED j FLASHING (CLEAN MASONRY j METALI DOOR FRAME EXTERIOR SCALE: 11/2" = V-0" O 0 O LO > 4 APEX C) N t6 N M J W 4 J � J_ Z tds O true design studios Y U 9000 REGENCY SQUARE BLVD. C) SUITE 100, JACKSONVILLE, FL 32211 c vi T_ 0 W D 4- Z) N c �_ � J 01HOMON' to m LU Of Q U U Z LU c O O O ti LO ti O Z U) W v , _Z W W Of W W Z Z G w Q 0 o 0 o .J U- L11 W O < W w O XU = Q Z O 0 Q Z U Z a LL (D W O -- Q J O U Z PROJECT NO: U W LLI � ~ Z DRAWN: IX DVO Q CHKD: Q Q TSD U- o m Q 0 LO W U) z � W O J Q W U 2 U Q U) Z 0 U) Z O Q � U LL U) Q Q Z U > REVISIONS: )ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 VERIFY AC COND LOCATION W/ SURVEY 1st LEVEL ELECTRICAL PLAN 1/4" = 1'-0" WHEN PRINTED ON 22"x34" s REFRIGERATOR. ®�® ° ®®0 BATHRECEPTACLES DISHWASHER (A)(G)BATH LIGHTS + FANS 9 ®�� ©KITCHEN (A) ®®�GREAT ROOM (A) IF®� OWNERS OUTDOORi m BEDROOM y HEAT) ELECTRICAL ®®® WATER HEATER R=RECEPTACLE L=LIGHTING F =FIXED EQUIPMENT M=MOTOR TC =TIM KLOCK CONTROLLED CKT A= COMBINATION TYPE AFC1 C/B G:=GFCIC/B WP GFI VERIFY AC COND LOCATION W/SURVEY ELECTRICAL LEGEND SINGLE POLE SWITCH 6 DOOR BELL BUTTON 3 3-WAY SWITCH CHIME DOOR BELL CHIME 4-WAY SWITCH GARAGE DOOR BUTTON t DIMMER SWITCH El GARAGE DOOR D OPENER 220 VOLT OUTLET 7..l GFCI DUPLEX OUTLET GFI DUPLEX OUTLET 8 CEILING OUTLET A I AFCI DUPLEX OUTLET R FLOOR OUTLET ® SMOKE DETECTOR B JUNCTION BOX © CARBON MONOXIDE ® CARBON MONOXIDE & DETECTOR SMOKE DETECTOR TELEVISION OUTLET A NETWORK OUTLET PANEL SERVICE PANEL A TELEPHONE OUTLET �SERVICE METER m GARBAGE DISPOSAL WALL MOUNT LIGHT SINGLE SCONCE FLOOD LIGHT DOUBLE SCONCE STRIP LIGHT BATH FAN & LIGHT COMBO - VENT TO EXT ® STAIR LIGHT ® BATH FAN - VENT TO EXT CLOSET CASTER CASTER LIGHT UNDER CABINET LIGHT PULL CHAIN LIGHT 4- KEYLESS LIGHT FLUSH MOUNT LIGHT HANGING HANGING LIGHT �PNDT HANGING PENDANT fiy MINIATURE PUCK LIGHT MINI LIGHT LED FLUSH MOUNT RECESSED EYEBALL DISC LIGHT LIGHT FLUORESCENT LIGHT ®FIR FLUORESCENT LIGHT RECTANGULAR ROUND PRE -WIRE FOR CEILING FAN CLG FAN ROUGH -IN PRE -WIRE FOR LIGHTED CLG FAN w/ CEILING FAN LIGHT ROUGH -IN 0 c� O O 0 CN APEX c v O N rn N co J tds �i J true design studios a) z O U) U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 co � o o O W DeRsHOMON' cn J w �I U U z W (9 W w O O O O ti uz d'U') ti O 0 U) zcn illlll. W oo _ U) W ct z LL z W m J O C/) w W V Q W O z w W W o V wW O J X L z O z O Q 0 w w a z ry O a U ILL Q w o Abbott Park Q O U J (n U_ LOT 008-01 p Q w v Q z z (D ca U) O PROJECT NO: w 1 2021.003451 O w z DRAWN: O U LDG o w CHKD: LO JAC X w w a J Q U Q 00 z 0 LIj z O w U) Q z z (n QQ O 04-10-2019 Q �- w U REVISIONS: LL H Q No. Description Date W (n J c� U) 1 0 O z = o U W I— X W El 00 d Q } :)ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 i H L PRODUCT APPROVAL LISTING -LOT SPECIFIC (A GENERAL) - EXPIRATION DATE 2355-R7 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 9589-R6 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 1.1471R-5 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 1.0007R-8 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 0456aR5 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 13872uR4 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020FBCR 12/31/2021 106 7-R5 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 1.0850-RS SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020FBCR 12/31/2021 1085-RS SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 1168-RS SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 1.1496-RS SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020FBCR 12/31/2021 10455.R5 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 1.0446.R SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 10447.RS SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 10446.R6 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 10441SR5 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 1 628-RS SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 1080<RS SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020FBCR 12/31/2021 11495.R5 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 13872-R4 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 13975-R SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 13904.R5 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 15353-R3 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 10 a31.R-5 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 15730-R4 SIMPSON STRUCT. COMP. WOOD CONNECTORS 2020 FBCR 12/31/2021 FL 1.5299-R5 KAYCAN LTD. PANEL WALLS SOFFIT 2020FBCR 3/2/2023 FL 32502 PLYGEM PANEL WALLS SOFFIT 2020 FBCR 12/31/2023 FL15349-R7 MI WINDOWS & DOORS FIXED GLASS 2020 FBCR 11/18/2021 FL17499-R8 MI WINDOWS & DOORS SINGLE HUNG 2020 FBCR 12/31/2021 FL17880-R6 MI WINDOWS & DOORS SLIDING GLASS DOOR 2020 FBCR 12/31/2021 FL 1.5353.R-5 MI WINDOWS & DOORS WINDOWS MULLIONS 2020 FBCR 12/31/2021 FL1789-R3 GLOBAL PROTECTION PRODUCTS SHUTTERS STORM PANELS 2020 FBCR 12/31/2021 FL 5 7&R5 CLOPAY BLDG. PRODUCT CO. EXT. DOORS SECTIONAL 2020 FBCR 12/31/2021 FL 1.4998.R5 Silverline Ext. Doors Gliding Patio Door 2020 FBCR 08/03/2021 FL 1533ZR6 MI Windows & Doors Ext. Doors Sliding Glass Door 2020 FBCR 12/31/2024 FL 20451-R5 THERMA-TRU EXT. DOORS SWINGING EXT. DOOR 2020 FBCR 12/31/2021 FL 10758.R8 OWENS CORNING ROOFING ROOFING ACCESSORIES 2020 FBCR 10/13/2021 FL27945.1 OWENS CORNING - RHINO U20 ROOFING UNDERLAYMENT 2020 FBCR 12/31/2021 FL 4103. 311 TAMKO ROOFING ROOFING ACCESSORIES 2020 FBCR 12/31/2021 FL 3031.0-RI IKO SHINGLES 30 YEAR 2020 FBCR 12/31/2024 FL 3792.2 LAMANCO, INC. ROOFING ROOF VENTS 2020FBCR 8/17/2021 FL 15&R13 CASTCRETE STRUCTURAL LINTELS 2020 FBCR 5/21/2022 FL10477-R8 James Hardie Building Products, Inc Panel Walls SIDING 2020 FBCR 12/31/2023 FL19901-R4 James Hardie Building Products, Inc Panel Walls SIDING 2020 FBCR 12/31/2023 F113192-R8 James Hardie Building Products, Inc Panel Walls SIDING 2020 FBCR 12/31/2023 FL13223-R5 James Hardie Building Products, Inc Panel Walls SIDING 2020 FBCR 12/31/2023 FL13265-RS James Hardie Building Products, Inc Panel Walls SOFFIT 2020 FBCR 12/31/2023 THIS IS A COMPILATION OF PRODUCT APPROVAL LISTING IN THE STATE OF FLORIDA VERIFY PRODUCTS WITH THE APPROVED LIST PRIOR TO PURCHASE AND INSTALLATION. REFER TO THE FLORIDA FBCR 2020 (7th EDITION) BUILDING CODE INFORMATION SYSTEM @ WWW.FLORIDABUILDING.ORG CONTROL DATE: 02/03/2021 O U N LO CY � 0 N CR APEX N tt5 co N J L J J C z tds -6 O true design studios j Y Q 9000 REGENCY SQUARE BLVD. o SUITE 100, JACKSONVILLE, FL 32211 0 w , U) CY, J 11HOMN", Q Z) 0 ri m U z aD n 0 0 0 CY) , ti V O z cn H Q w z � Q V C� > w w - O z Q � J .. z L.L , ~ w O 0 am — U 0 0. J L L.L 0. Q z Q 0 O w < ~ O X W O O o 0 w O z LL z J Q , U (D O 0 J w O PROJECT NO: 2 z U 0 UJ DRAWN: x MJP o Wa CHKD: U_ Q NE O X o 01 Q p ,m LO m — 0 w J w Q z U O U) w z z Q O F- m U z U Q REVISIONS: } No. Description Date w C� U) O w O -- z w = J W U X ., 111 z < A001 0 0 )ocuSign Envelope ID: 8912F9C8-E511-4OB6-BEAF-12FOECADCDD3 TABLE 7: METAL CONNECTOR SCHEDULE MOTFC 9 1 A i FnFNn DESIGN CRITERIA AND LOADS TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS AVITCQ Q d Building Code Florida Building and Residential Codes , 7th Edition (2020) Code for Design Loads ANSI/ASCE 7-16 ROOF LOADING' ............................................... Cd = 1.25 TOP CHORD LIVE LOAD..................................20 PSF TOP CHORD DEAD LOAD................................7 PSF (TILE = 15 PSF) BOTTOM CHORD LIVE LOAD ATTICS WITH LIMITED STORAGE ............... 20 PSF ATTICS WITHOUT STORAGE .......................10 PSF (NON -CONCURRENT) BOTTOM CHORD DEAD LOAD.......... 5 PSF WIND LOADING ................................................. Cd 1.60 ASCE 7-16, 3S GUST........................................139 MPH BASIC WIND SPEED EXPOSURE CATEGORY.................................0 BUILDING CATEGORY.....................................II ENCLOSURE CLASSIFICATION ...................... ENCLOSED INTERNAL PRESSURE COEFF ........................0.18 C&C DESIGN PRESSURES..............................(SEE TABLE 1) FLOOR LOADING..............................................Cd = 1.00 TOP CHORD LIVE LOAD..................................40 PSF TOP CHORD DEAD LOAD................................10 PSF BOTTOM CHORD LIVE LOAD..........................0 PSF BOTTOM CHORD DEAD LOAD........................5 PSF SPECIAL FLOOR (GAME ROOM) LOADING .... Cd = 1.00 TOP CHORD LIVE LOAD..................................60 PSF TOP CHORD DEAD LOAD................................10 PSF BOTTOM CHORD LIVE LOAD ...........................0 PSF BOTTOM CHORD DEAD LOAD........................5 PSF MAXIMUM FLOOR TRUSS SPACING...............16" O.C. DEFLECTION CRITERIA LL / 240 ROOF TRUSSES .............................................. TL / 180 TL MAX 1" UP TO 40' SPAN LL 1480 TL / 360 OPEN WEB FLOOR TRUSSES ....................... ILL /480 TL/240 WOOD I JOISTS ............................................... TL MAX''/z" LL / 360 BEAMS'.............................................................TL / 240 NOTES: 1. PORCH BEAMS AND BEAMS SUPPORTING EXTERIOR WALL ABOVE SHALL NOT EXCEED %" DEFLECTION TABLE 1: COMPONENT AND CLADDING DESIGN PRESSURES WINDOWS AND DOORS EFFECTIVE WIND AREA ZONE DESIGNATION IZ - Interior Zone (psf) EZ - End Zone (psf) 0 - 20 ft2 +28.54 -30.96 +28.54 -38.22 21 - 50 ft2 +27.17 -29.59 +27.17 -35.47 51 - 100 ft2 +25.52 -27.94 +25.52 -32.17 101 - 200 ft2 +24.25 -26.67 +24.25 -29.64 VINYL SOFFIT MAX PRESSURE (psf) +28.6 -38.3 GARAGE DOOR PRESSURE +21.7 -24.6 END ZONE KEY MAP END ZONE: END ZONES SHALL BE TAKEN AS THE 1ST 4.0' PER FIGURE R301.2 (7) 1 L_ L J 1ST FLOOR 4.0 F (TYP) END ZONE DESIGNATION p O STUCCO AND DIRECTLY MIN 1%2" 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICALLY OR (%6" 24/16 w = ADHERED STONE INSTALLED HORIZONTALLY) W/ 8d COMMON: 6" O.C. AT PANEL EDGES, 12" O.C. IN THE . r N (NOTE 6) FIELD. 2x4 BLOCKING IS RECOMMENDED AT UNSUPPORTED PANEL EDGES. w=P v J z ALL OTHER VENEER MIN 15/32' 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICAL OR HORIZONTAL (NOTE 8) W/ 8d COMMON: 6" O.C. EDGES AND FIELD (UNBLOCKED HORIZONTAL PANEL EDGES); 6" O.C. AT PANEL EDGES, 6" O.C. IN FIELD (BLOCKED HORIZONTAL PANEL EDGES) Y C� rn TILE AND METAL ROOF MIN'%32" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION ds (NOTE 7) PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 4" O.C. AT PANEL EDGES AND Lu= 6" O.C. IN THE FIELD 0 w H MIN %fi' 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED WITH LONG DIMENSION 0 T Z SHINGLE ROOF PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 6" O.C. AT PANEL EDGES, 6" O.C. IN THE FIELD. FLOOR DECK SHEATHING: 2Y32' T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O.C. IN THE (NOTE 5) FIELD. MIN %" OSB 6R PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d PORCH CEILING BOARD SHEATHING: COMMON: 3" O.C. AT PANEL EDGES 12" O.C. IN THE FIELD OR MIN ' 2" EXTERIOR GYPSUM CEILING BOARD, FASTEN w/ 5d x 1 /" COOLER NAIL OR NO.6 x 1 /4' LONG SCREWS @ 4" O.C. EDGE , 8" O.C. FIELD NOTES: 1. FOR SHEATHING THICKNESS GREATER THAN 15/32" TEGORY, USE RSRS-03 NAILS. 2. COMMON NAILS IN WALL SHEATHING MAY BE SUBS ITUTED W/ 8d GALVANIZED BOX NAILS. 3. ZIP WALL SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED WOOD STRUCTURAL PANEL. 4. ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF CURRENT APPROVED APA.MANF. SPECIFICATIONS. 5. FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TO REDUCE SQUEAKING, RSRS-01 NAILS OR 8d SCREW NAILS ARE RECOMMENDED. 6. 1 Y32" 32/16 SPAN RATED OSB OR PLYWOOD WITH BLOCKED PANEL EDGES IS AN APA RECOMMENDATION PER APA TECHNICAL BULLETIN Q370 WHEN STUCCO LATH IS ATTACHED DIRECTLY TO OSB OR PLYWOOD.. SHOULD BUILDER SPECIFICATIONS ALLOW, MIN STRUCTURAL REQUIREMENTS ARE 24/16 SPAN RATING INSTALLED HORIZONTALLY OR VERTICALLY PER FLEXIBLE VENEER WALL SPECIFICATIONS. INCLUDES FULL AND PARTIAL HEIGHT VENEER APPLICATIONS. 7. 1%32" PLYWOOD IS A WARRANTY LIMITATION COMMON TO TILE MANUFACTURER'S MINIMUM RECOMMENDATIONS. SHOULD WARRANTY AND INSTALLATION REQUIREMENTS ALLOW,'%2" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF. 8. WOOD STRUCTURAL PANEL MAY BE INSTALLED VERTICALLY OR HORIZONTALLY W/ UNBLOCKED HORIZONTAL PANEL EDGES. 9. ROOF DECK SHEATHING HAS BEEN ENGINEERED TO RESIST ASCE 7-16 WIND LOADS IN ACCORDANCE WITH FRC R301.2.2.1 TABLE 4: NAIL SIZE LEGEND TABLE 5: FASTENERS IN NOTES 1, 2, 3, 4 DIAMETER PRESSURE TREATED LUMBER LENGTH 8d COMMON 0.131" 2-1/2' RSRS-01 0.113" 2-%" RSRS-03 0.131" 2-1/2" 10d 0.131" 3" 10d COMMON 0.148" 3" 12d COMMON 0.148" 3 '/4' 16d SINKER 0.148" 3-'/<" 11 16d COMMON 0.162" 3-'/z" NOTES: 1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED. 2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS BEFORE APPLICATION OF PROTECTIVE COATING. 3. WHEN A BORED HOLE IS REQUIRED TO PREVENT SPLITTING OF A WOOD DUE TO FASTENER PENETRATION, THE BORED HOLE SHALL NOT EXCEED 75% OF THE NAIL OR SPIKE DIAMETER. 4. THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4. PRESERVATIVE FASTENER TYPE ACZA STANDARD CARBON STEEL SODIUM BORATE (NOTE 1) STAINLESS CONNECTORS AND FASTENERS REQUIRED. CONNECTORS MUST HAVE Z-MAX, G120 OR TRIPLE ZINC ALL OTHER PT COATED FINISH. (INCLUDING ACQ & MCQ) ALL FASTENERS MUST BE HOT DIPPED GALVANIZED. NOTES: 1. SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY EXPOSED TO EARTH OR WEATHER AND HAVE BEEN PROVEN TO BE NON -CORROSIVE TO CARBON STEEL FASTENERS. CONCRETE AND FOUNDATION NOTES 1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTINGS= 2,500 PSI AT 28 DAYS (UNO). 2. CONCRETE COMPRESSIVE STRENGTH FOR SLAB = 2,500 PSI AT 28 DAYS (UNO). 3. ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO). 4. ALL REINFORCING STEEL SHALL HAVE 90 DEG14EE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE INSTALLED AT ALL REENTRANT CORNERS. 5. FIBERMESH IS AN ACCEPTABLE ALTERNATIVE, AND SHALL NOT REQUIRE WWF. FIBER LENGTHS SHALL BE %" TO 2" IN LENGTH. DOSAGE AMOUNTS SHALL RANGE FROM 0.75 T) 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE CERTIFICATION OF COMPLIANCE WHEN REQUESTED BY THE BUILDING OFFICIAL. 6. MASONRY STEMWALL AND MONOLITHIC FOOTING ARE INTERCHANGEABLE. 7. EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 PSF IN ACCORDANCE WITH TABLE R401.4.1, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. 8. CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WITH CODE APPROVED PROVISIONS FOR PREVENTION OF SUBTERRANEAN TERMITES. 9. STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION. CONTACT ENGINEER OF RECORD IF THIS CONDITION EXISTS. 10. TO CONTROL CRACKING, CUT V SAWCUTS IN THE SLAB IN A 15'x15' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT. CONTACT FOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NOT REQUIRED WHEN WWF OR FIBERMESH ARE INCLUDED WITH CONCRETE WORK. 11. DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DO NOT DETERMINE FOOTING LOCATION FROM ARCHITECTURAL PLANS OR FRAMING PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINATE FROM USE OF FOUNDATION PLAN ALONE, CONTACT THE ENC4NEER OF RECORD. PRE-ENGINEERED TRUSSES & I -JOISTS 1. ROOF TRUSS TOP CHORDS SHALL HAVE A MINIMUM SPECIFIC GRAVITY OF 0.49 (SYP SPECIES OR BETTER). 2. ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS SHALL BE PREPARED IN ACCORDANCE WITH ANSI/TPI AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION. DESIGN CRITERIA IS LOCATED ON SHEET ST-1 OF THE PLAN SET. TEMPORARY BRACING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE. 3. TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION, SPAN DIRECTION, SPACING, BEARING LOCATION AND NAMING CONVENTION OF THE LAYOUT SHOWN HERE. 4. THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS. 5. TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN OF THE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE. AS SUCH, THE REPORTED UPLIFTS ON THE TRUSS SHOP DRAWINGS MAY BE DISREGARDED. 6. I -JOISTS FABRICATED TO ACHIEVE THE FLOOR ,PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SEE DESIGN CRITERIA, THIS SHEET. USP & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOW ARE EQUAL ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE SIMPSON SIMPSON FASTENERS MITEK USP FASTENERS SIMPSON SIMPSON FASTENERS MITEK USP FASTENERS (8)%X 1 %" SIDS SCREWS (8)%" x I%" WS15-GC DTT2Z IN STUDY2" 0 X 4 %2' WOOD SCREWS IN STUD (9) 10d COMMON (9) 10d (NOTE 2) EMBED EPDXY OR DTB-TZ Y2 0 x 4Y2' EMBED EPDXY CS18 EACH END CS20 COMMON SCREW ANCHOR OR SCREW ANCHOR EACH END (18)0.162"x2'/2'IN (18)0.162"x2'/z"IN HTT4 STUD/BEAM/TRUSS STUD/BEAM/TRUSS (7) 10d x 1 '/z" (7) 1Od x 1 'Y2" (NOTE 2) %" 0 x 6" EMBED ANCHOR HTT45 q," 0 x 6" EMBED ANCHOR MTS12 EACH END MTW12 EACH END IN CONCRETE IN CONCRETE (26) 0.162" x 2 '/z' IN (26) 0.162" x 2 '2" IN HTT5 STUD/BEAM/TRUSS HTT45 STUD/BEAM/TRUSS MSTA24 (9) 10d COMMON MSTA24 (9) 10d COMMON (NOTE 2) 46" 0 x 6" EMBED ANCHOR V 0 x 6" EMBED ANCHOR EACH END EACH END IN CONCRETE IN CONCRETE (20)%" x 3" SIDS SCREWS (24) 3" WS IN STUD HDQ8-SDS3 IN STUD GROUP PHD8 GROUP 7/8' 0 x 12" EMBED MSTA36 (13) 10d COMMON MSTA36 (13) 10d COMMON 78' 0 x 12" EMBED ANCHOR IN CONCRETE EACH END EACH END ANCHOR IN CONCRETE (7) 10d x 1 Y2' IN TRUSS (7) 1Od x 1 %" IN TRUSS (7) 10d COMMON IN (7) 10d COMMON IN META12 4" WET EMBED IN HTA16-18 4" WET EMBED IN MSTAM36 WOOD FRAMING (4) W x 2 YV TITEN MSTAM36 WOOD FRAMING (5) W x 2 W TAPCON IN GROUTED BLOCK WALL GROUTED BLOCK WALL SCREWS IN MASONRY MASONRY (8) 10d x 1 Y2" IN TRUSS (9) 10d x 1 %" IN TRUSS (11) 10d x 1 'W IN (11) 10d x 1 Y2' IN META20 4" WET EMBED IN HTA20-18 4" WET EMBED IN HTS20 TRUSS/RAFTER (11) 10d x 1 %" IN HTW20 TRUSS/RAFTER (11) 10d x 1 %" IN GROUTED BLOCK WALL GROUTED BLOCK WALL STUD STUD (12) 10d x 1 %" IN (8) 10d x 1'/2" IN ABU44 (12) 16d COMMON NAILS PAU44 (12) 16d COMMON NAILS HTSM20 TRUSS/RAFTER HTWM20 TRUSS/RAFTER (NOTE 6) 48" 0 x 7" EMBED EPDXY �8" 0 x 7" EMBED EPDXY (12) 10d x 1 '/2' IN (4)/," x 3" WEDGE BOLT STUD OR EQUIVALENT IN STUD (12) 16d COMMON NAILS (12) 16d COMMON NAILS (5) 8d x 1 %" IN (5) 8d x 1 Yz" IN ABU66 4 " 0 x 7" EMBED EPDXY PAU66 4 " 0 x 7" EMBED EPDXY H2.5T/ TRUSS RT7/ TRUSS (NOTE 6) (12" EMBED AT GARAGE (12" EMBED AT GARAGE HA8 (5) Sd x 1'2" IN RT7AT (5) 8d x 1'/2' IN DOOR RETURNS) DOOR RETURNS) TOP PLATE TOP PLATE HU48, (14) 16d COMMON IN HD48, (14) 16d COMMON IN (5) 10d x 1'/" IN (5) 10d x 1 Y2" IN HUC48, HEADER HD481F, HEADER H8 TRUSS RT8A TRUSS HU28-2, (6) 10d COMMON IN BEAM HD28-2, (6) 10d COMMON IN BEAM (5) 1Od x 1'/z" IN (5) 1Od x 1'/2" IN HUC28-2 HD28-21F TOP PLATE TOP PLATE HU410, (18) 16d COMMON IN HD410, (18) 16d COMMON IN (16) 1Od COMMON TO HUC410, HEADER HD4101F, HEADER LGT2 TRUSS/RAFTER 'W LUGT2 TRUSS/RAFTER HU210-2, (10) 10d COMMON IN HD210-2, (10) 10d COMMON IN (7) W x 2 TITEN (5)'0" x 3" WEDGE BOLT HUC210-2 BEAM HD210-21F BEAM SCREWS IN MASONRY OR EQUIVALENT (22) 16d COMMON IN (22) 16d COMMON IN (26) 16d SINKER (28) 16d SINKER IN WALL HUC212-2 HEADER HD212-21F HEADER LGT3 WALL FRAMING LUGT3 FRAMING 10 10d COMMON IN BEAM 10 10d COMMON IN BEAM (12) SIDS '/<" x 2 '/" (1 (12) WS25 '/:' x 2 '/z" + + (4)/4' x 1 2" SIDS SCREW 4 '/:' x 1'/z" WS15 SCREWS () " IN TRUSS IN TRUSS IN TRUSS/RAFTER TRUSS/ RAFTER HGA10KT (4)% x 3" SIDS SCREWS HGA10 4 ' () %" x 3" WS3 SCREWS IN TOP PLATE IN TOP PLATE SDWC14500, SDWC15600 NO USP EQUIVALENT (4) SIDS W x 1 %" SCREWS (4) W x 1'/2' WS15 SCREWS HGAM10KTA IN TRUSS/RAFTER HGAM10KT IN TRUSS/ RAFTER (4) /s x 1 / WEDGE BOLT (4) %' x 2'/+" TITEN SCREWS OR EQUIVALENT IN IN MASONRY MASONRY NOTES: 1. REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS. 2. PRODUCTS SELECTED USING SIMPSON 2019-2020 CATALOG. PRODUCTS MAY BE SUBSTITUTED WITH EQUAL OR BETTER APPROVED ALTERNATES. 3. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS. 4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT FOR FOR SPECIFIC FASTENING REQUIREMENTS. 5. POSITIVE PLACEMENT GUN NAILS, 2 %" LONG, WITH EQUIVALENT DIAMETER TO COMMON NAILS SPECIFIED ABOVE MAY BE USED FOR ABU POST BASE ANCHORS, CS16, AND MSTA FLAT STRAPS. 6. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES W 0 x 2 %" TITENS ILO 16d. CONCRETE REQUIRES EQUIVALENT NUMBER OF W 0 x 1 M." TITENS ILO 16d. MASONRY NOTES 1. ALL MASONRY UNITS SHALL HAVE fm = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL BED. 2. SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER TYPE HORIZONTAL JOINT REINFORCEMENT 3. ALL GROUT TO MIXED PER ASTM C476 STANDARDS. fc = 3,000 PSI. 4. VERTICAL WALL REINFORCING TO BE ASTM A615 GRADE 60 REBAR. 5. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO BE 30". 6. VERTICAL REINFORCING TO HAVE 10" STANDARD HOOK INTO BOND BEAM. DOWEL TO HAVE 10" STANDARD HOOK INTO FOOTING 7. PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET. 8. PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE. OR "OR" SHALL MEAN THAT EITHER OPTION PROVIDED IS AN EQUAL O ALTERNATIVE FOR THE APPLICATION SHOWN O UNO UNLESS NOTED OTHERWISE ON PLAN OR DETAIL N LO FOR ENGINEER OF RECORD EW EACH WAY 04 04 OSB ORIENTED STRAND BOARD 00 WSP WOOD STRUCTURAL PANEL 140 SYP SOUTHERN YELLOW PINE 0) SPF SPRUCE -PINE -FUR , CONT CONTINUOUS O.C. ON CENTER r N LSL 1.55E TIMBERSTRAND LSL ENGINEERED LUMBER, 1 '/" WIDE, UNO. N (3 W WIDE LSL BEAMS ARE EQUIVALENT TO 2-PLY 1 '/" BEAM) co LVL 2.0E MICROLLAM LVL ENGINEERED LUMBER, 1 W WIDE _j PSL 2.0E PARRALLAM PSL ENGINEERED LUMBER, 3 '/" WIDE, LINO. SYS 42 PROPERLY RATED OPEN WEB HEADER W J J INTERIOR ROOF LOAD BEARING WALL, SPECIFICATIONS OUTLINED ON TYPICAL WALL SECTIONS, DETAIL SHEETS Z 0 INTERIOR BEARING WALL WITH NO UPLIFT. NO UPLIFT ANCHORS REQUIRED. MINIMUM BOTTOM PLATE ANCHORAGE IS '/2' ANCHOR @ 8'-0" O.C. (UNO ON FRAMING PLAN OR U SW SPECIFICATIONS) STRUCTURAL WOOD BEAM O STUD COLUMN KEYNOTE O r- NUMBER OF SDWC15600 CONNECTING TOP PLATE TO STUDS. w f- 2 2 STUDS U) w 2 ANCHOR NUMBER OF STUDS BELOW BEAM/GIRDER TRUSS. STUDS U) TO MATCH WALL FRAMING SIZE AND GRADE, UNO. ADDITIONAL CLARITY FOR THE LOCATION OF THE STUD COLUMN 0 J co BOTTOM OF STUD COLUMN CONNECTION W 1ST LEVEL STUD COLUMN: HOLDDOWN REQUIRED AT BASE OF COLUMN w 2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL Q COLUMN TO 1ST LEVEL STUDS/HEADER/BEAM. "ANCHOR" REQUIRES BOTTOM PLATE ANCHOR WITHIN 3" OF STUD COLUMN NUMBER OF SDWC15450 CONNECTING STUDS TO BOTTOM PLATE } HEADER STRAPPING KEYNOTE Z NUMBER OF STRAPS CONNECTING HEADER TO JACK STUD W (D 1 MSTA24 TYPE OF STRAP CONNECTING HEADER TO JACK STUD LU 1 DTT2Z KING/JACK GROUP BOTTOM CONNECTION O 1 ST LEVEL STUD GROUP: HOLDDOWN REQUIRED AT BASE OF STUD GROUP C) 2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL STUD GROUP TO 1ST LEVEL STUDS/HEADER/BEAM. NUMBER OF HOLDDOWNS/STRAPS AT BASE OF KING/JACK GROUP u7 ~ NON -BEARING HEADER FRAMING KEYNOTE NO HDR # NUMBER OF KING STUDS EACH SIDE OF OPENING Z HEADER MAY BE FRAMED AS NON BEARING HEADER DUE TO LIGHTLY U) LU LOADED CONDITIONS ABOVE W Z #2 SYP HEADER FRAMING KEYNOTE (2) 2x10 - 1 / 2 NUMBER OF KING STUDS EACH SIDE OF OPENING m NUMBER OF JACK STUDS EACH SIDE OF OPENING ILL W DEPTH OF LOAD -BEARING #2 SYP HEADER W NUMBER OF PLIES IN HEADER Z ENGINEERED LUMBER HEADER FRAMING KEYNOTE Z W (2) 9'/z' LSL- 1 /2 NUMBER OF KING STUDS EACH SIDE OF OPENING Q 00 NUMBER OF JACK STUDS EACH SIDE OF OPENING HEADER MATERIAL (LSL, LVL, PSL, OR SYS42) 0 DEPTH OF LOAD -BEARING EWP HEADER J LL NUMBER OF PLIES IN HEADER (1 '/," WIDE UNO) Z HEADER FRAMING o 1. ALL HEADER JACK AND KING STU IDS SHALL BE FASTENED TO EACH OTHER WITH (2) ROWS 10d @ 8" O.C. STAGGERED. 0 2. NON BEARING HEADERS: DUE TO LIGHTLY LOADED CONDITIONS, 49" OR LESS CLEAR -OPENINGS IN AN a. EXTERIOR WALL DO NOT REQUIRE LOAD BEARING HEADER, SEE PLAN. w 3. FASTEN ALL MULTI -PLY HEADERS TOGETHER WITH (2) ROWS 10d @ 8" O.C., STAGGERED ALONG EACH EDGE. 0 4. FASTEN ALL HEADERS TO KING STUDS WITH (3)8d TOE NAILS . 5. IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECORD. Q 6. LINO ON PLAN, MIN (1) SDWC15600 TOP PLT TO KING STUD AND (1) SDWC15450 KING STUD TO BOTTOM PLATE _ CONNECTION REQUIRED EACH SIDE OF OPENING (NO CONNECTION REQUIRED FOR OPENINGS AT FIRST FLOOR HEADER WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE. O 7. TOP PLATE TO HEADER CONNECTION PER ONE OF THE FOLLOWING (NO CONNECTION REQUIRED FOR ILL. 39" OR LESS, OR AT FIRST FLOOR HEADERS WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE: Q • SDWC15600 @ MAX 32" O.C. AS SHOWN, "ALTERNATE SECTION (HEADERS),ST-5 •SPHw/(12)10dx1-Yz"@16"O.C.OR b • DSP w/ (14) 10d x 1- 1/2" @ 16" O.C. OR Z_ • FASTEN TRUSS DIRECTLY TO HEADER w/ MTS OR HTS w/ (14) 10d x 1 %" (OR EQUAL APPROVED BY EOR). } 8. CRIPPLE BLOCKS BELOW LOAD -BEARING HEADERS MAY BE FRAMED AT 24" O.C. Ur 0 O FRAMING NOTES z 1. SIMPSON ACRYLIC -TIE ADHESIVE OR EQUAL SHALL BE USED IN ALL DRILLED AND EPDXIED ANCHOR APPLICATIONS. U ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCING STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN H A HOLE AS SPECIFIED BY MANF (TYPICALLY 1/16" TO 1/8" GREATER THAN SPECIFIED ANCHOR DIAMETER). ADHESIVE/EPDXY MUST FILL THE HOLE IN THE CONCRETE AND WOOD BOTTOM PLATE. MANUFACTURER'S X W SPECIFICATIONS MUST BE FOLLOWED FOR PROPER INSTALLATION. 13- 2. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY, UNO. ALL WATERPROOFING AND FIRE SAFETY Q SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER. x 3. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN Q TABLE 2304.10.1 4. BEAMS IDENTIFIED BY NUMBER ON PLAN ARE TO BE PROVIDED BY TRUSS MANUFACTURER OR LUMBER SUPPLIER. 5. FASTEN ALL MULTI -PLY STUD COLUMNS AND CORNERS TOGETHER WITH (2) ROWS 10d @ 8" O.C. STAGGERED. m UPPER LEVEL MULTI -PLY STUD GROUPS BELOW ALL GIRDER LOCATIONS TO BE CONTINUOUS THROUGH FLOOR 0 SYSTEM TO FOUNDATION. (NOT REQUIRED BELOW HEADER JACK/KING STUD GROUPS) LLI 6. FASTEN ALL STUDS TO BOTTOM AND TOP PLATES WITH (4)8d TOE NAILS OR (2)16d COMMON END NAILS. z 7. FASTEN ALL TRUSSES AND RAFTERS TO TOP PLATES WITH (3)8d TOE NAILS. 8. ALL MULTI -PLY TRUSS GIRDERS AND BEAMS TO HAVE SOLID STUD GROUP BELOW MATCHING GIRDER OR BEAM O THICKNESS AND MATCHING WALL STUD SPECIFICATIONS AS NOTED ON STRUCTURAL PLAN, UNO. W 9. EXTERIOR WALL DESIGN ASSUMES CONTINUOUSLY SHEATHED WITH OSB OR PLYWOOD z In D O H U LL Q (D O J O Z _ U W H X W Q CMUIMETAL CONNECTOR ENGINEERING APEX tdsQ true design studios >� 9000 REGENCY SQUARE BLVD. SUITE 100, JACKSONVILLE, FL 32211 0 U) mW LL Z jjj O W J -U) 1­ 2 V O W 0 J V W � W X L a z 0 W Z_ d LL W Abbott Park -� U LOT 008-01 0 W Q (D PROJECT NO: ILLI 2021.003451 0 LL O DRAWN: LDG o CHKD: U) MJP U) W cn U Z ned.ly Q `. xz 0 g J F • 4U . '� (A O N A\_ '����►n�►►'►► Q 04-10-2019 0 w REVISIONS: w No. Description Date w J Q U U) F- O Z O 0 STm1 )ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 2020 V1.0 co VERIFY AC COND LOCATION W/ SIM 9" CURB 5 SITE PLAN ST-2D 0 ti 65'-0" 2'-8" ,, 2'-4" ■ ■ n ■ - ■ ■ i ■ ■ ■ I ■ ■ --——— — — —I-- co I I ■ I 1 `' 1 I-- I I 5 ;T-2D j - - plL - - I I ST-2D I 4 4i - I - ST-2D 411 I � I ST-2D I I I 24'-5 1/2" 5'-0 1/2" I T-6" I 2'4" 20'-8" I I I A T ST-2D I I UNDER DOOR ■I I I I 01. I- -4ll 1 , 5'-1 1/2" 4'-6" I - -- I 11'-8" 4 ,1�------,K-———-,K — ort----- - - - - - I ST-2D I \ 001 I I ■ I1 _3^,�r I 4 5 ......... .._ - I ST-2D ST-2D 2'_8 1 /Z- - - - - - _ 14'-0 1/2 --- - - ,I� B OPT 6 -L — I I O ST-2D Z 3'-4" 2'-8" c-'n 0 oil I A 1 0O O.1 t�}- cn00 LL � �---------� iwg I B I0 O '- - - - - 1 /2- - - - - gl�ll � ■ v I I I ■ I 1 1/2" I 6 I ■ I OPT ■ I ST-2D r-j I N� 1 I I ST-2D&4 I A.1 I 0„ N 1- - -- - t B I ST-2D o - , N ' ■ L — — — — — — — — — — — — — — — — — — — — — — — — J — — — — — — — — — — — — — — — — — — — —\— I— '...._` �::.. T _.— — — — — — — — — — — — — — J I VERIFY AC COND LOCATION W/ SITE PLAN T-8" V_m _ 56-0" FOUNDATION PLAN 1/4" = 1'-0" WHEN PRINTED ON 22"x34" 50 N a 2" 0 VENT TO EXT I I I I I GENERAL FOUNDATION NOTES: • CONCRETE SLAB ON GRADE SHALL BE MINIMUM 3 1/2" THICK AND O HAVE MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI UNO. O EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS N LO ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 psf, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED clp PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. IF CONTRACTOR OR BUILDING OFFICIAL DETERMINES THAT THE SOIL IS NOT SUITABLE FOR 2,000 PSF BEARING CAPACITY, CONTACT EOR. ADDITIONAL FOUNDATION WORK MAY BE REQUIRED. • SLIDING GLASS DOOR FRAMES MUST BE RECESSED INTO THE SLAB N IN ACCORDANCE WITH THE BUILDING CODE. CONSULT N ARCHITECTURAL PLANS FOR LOCATION OF SLIDING GLASS DOORS. M • MASONRY STEMWALL AND MONOLITHIC FOOTINGS ARE INTERCHANGEABLE. SEE SHEET ST-21D FOR ALTERNATE STEMWALL SECTIONS. 24" LONG #4 BAR IS RECOMMENDED TO BE INSTALLED AT ALL J RE-ENTRANT CORNERS, SEE "RE-ENTRANT CORNER DETAIL" ON J SHEET ST-21D. Z FOUNDATION KEYNOTES: DC1 Q NOTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN -� ❑8"x8" A DEEP THICKENED EDGE w/ (1) #4 CONT nn a 12" DEEP FTG UNDER BOX COLUMN, FTG TO BE p PROJECTED MIN 6" AS SHOWN W ❑C 16"SQx12" DEEP FTG F "DEEP FTG w4 3Qx () 30"SQx20" DEEP FTG W6"�Qx42 E'`DEEP FTG J w/ (4) #4 EW ( ) #4 m 48"SQx24" DEEP FTG #5 VERTICAL DOWEL TYP W ❑G w/ (5) #4 EW, T&B H- AS SHOWN, SEE MASONRY w NOTES ON ST-1 ❑I 1 1/2" SLAB EXTENSION d AT FULL ROUGH U) OPENING WIDTH } VI\ 1 V "II 1 I V VVI\1\LV 1 ABOVE THE CENTER LINE OF THE HORIZONTAL DRAIN PIPE Z W (D W -NOTE TO CONTRACTOR- w DR HORTON DOES NOT ALLOW FIBERMESH AS AN O ALTERNATIVE TO WWF AS SPECIFIED IN THIS PLAN SET 0 0) BORA-CARE OR OTHER DR HORTON APPROVED WOOD DESTROYING ORGANISM TREATMENT TO BE APPLIED AS DIRECTED BY PRODUCT MANUFACTURER AND DR HORTON. ti LO I` Z fA In W Z 2" 0 VENT � TO EXT m Of i W I W Z I � I I LLU I I 0 I � I O LL I z I � elf H a O w O LL Q Z C� 0 Z 2 w X W d Q m 0 O LU z U) O H _U LL Q U) } O O J O Z SANITARY ISOMETRIC w X W Q CMU/METAL CONNECTOR ENGINEERING APEX tds i7i s� 1v L true design studios 9000 REGENCY SQUARE BLVD. SUITE 100, JACKSONVILLE, FL 32211 PV� 0 CD M LLI LL ..z WUj ttttttnt>i � O cry O M Q Q W L1J W � J w LLJ W LL x QZ O 0 z a LL w Abbott Park Q U LOT 008-01 0 w H z PROJECT NO: 1 jJ 2021.003451 0 LL DRAWN: O LDG o CHKD tfi MJP U) W J co Nis ck U 4 f.: tF432:.. �0 1V A� Q 04-10-2019 p w REVISIONS: w 2 No. Description Date w J -- Q U H O Z O 0 ST=2 )ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 } EXISTING EXTERIOR CMU MIN. 3" EDGE DISTANCE STRIP OF WWF FROM F.F.E. TO MIN. 6" BELOW GRADE. WWF TO EXISTING FOUNDATION FACE w/ (2) ROWS OF 3/s' DIA. TAPCONS OR CUT NAILS @ 24" O.C. COVER FLUSH w/ 3000psi CONCRETE. D ° D I D EXISTING FOUNDATION. \ D D 8" CMU WALL OVERHANGS LESS THAN 1" CONCRETE SLAB W/ 6x6 W1.4 x W1.4 WWF OR FIBERMESH 0'-0" A.F.F. SEE ARCH — — — — (MAX 20" d DEEP) a Q a 4" EXTENSION UNDER BRICK VENEER 12" UNDER 1 STORY WALL `— VAPOR BARRIER 16" UNDER 2 STORY WALL 6 BEARING CURB STEP SECTION a 16" CONCRETE SLAB w/ 6x6 W1.4 x W1.4 WWF OR FIBERMESH VAPOR BARRIER 3 BEARING WALL FOOTING SECTION 1 A Il JAG ^r%krr1h11 1`lU0 BAR AS _AP AS SHOWN L/VI\ 111\VVVV VVIYVI\L 1 L FOOTING, SEE PLAN TYPICAL STEP IN FOOTING DETAIL DEGREE CONCRETE SLAB W/ 6x6 W1.4 x W1.4 WWF OR FIBER MESH 8" CMU CHAIR TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. LIJ fn Q o VAPOR BARRIER ��\\� I w o LO #4 OR #5 VERT REINFORCING UP TO 3 COURSES: 72" O.C. 4 TO 5 COURSES: 48" O.C. FOOTING TO BEAR ON FIRM //� / ADDITIONAL #4 OR#5 IN BRICK LEDGE UNDISTURBED SOIL VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN CAST -IN -PLACE FOOTING SPECS 1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT 2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT 2 STEMWALL SECTION 1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS MAY BE OBTAINED FROM THE ENGINEER OF RECORD. 2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. 0'-0" A.F.F. 1-6 (BEYOND) FLOATING CONCRETE w_ U-BLOCK W/ SLAB W/ 6x6 W1.4xW1.4 U (1) #4 OR #5 WWF OR FIBERMESH > Q ¢ CONT >ti wW U En -- — a, ; • FINISH 0 GRADE /, #4 OR #5 VERT REINFORCING \\\\\\�\\%/\\�/ /\\/ UP TO 3 COURSES: 72" O.C. 4 TO 5 COURSES: 48" O.C. FOOTING TO BEAR ON FIRM UNDISTURBED SOIL ADDITIONAL #4 OR #5 IN BRICK LEDGE VERT REINFORCEMENT TO 4" OPT BRICK LEDGE HAVE 6" BEND @BOTTOM NOTED ON FND PLAN CAST -IN -PLACE FOOTING SPECS 1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT 2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT (f�TEMWALL CURB SECTION . SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS MAY BE OBTAINED FROM THE ENGINEER OF RECORD. 2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. GROUT BOTTOM 3 COURSES OF EXISTING CMU WALL FOR LENGTH OF OVERHANG. FILL TO BOTTOM OF WINDOWSILL CMU STEMWALL MONO LITHIC SLAB 73'/2' CONCRETE SLAB W/ 6x6 WHERE NEEDED 8" CMU CHAIR BLOCK W/ (1) #5 (1) #4 OR #5 CONT. W1.4 x W1.4 WWF OR FIBERMESH CONTINUOUS TO EXTEND MIN 24" MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. INTO MONOLITHIC THICKENED EDGE MIN 24" LAP d a d MIN. 3" EDGE DISTANCE I VARIES PER 36" MAX ARCH PLANS \ \ \ \ \ 4" CONCRETE SLAB W/ a a a /\ /\ STRIP OF WWF FROM F.F.E. TO _ — — a - OR FIBER ME6x6 W1.4 x SH TRIP \\ \/\\\\� BOTTOM OF FTG. WWF TO �� //\//\//\ / \� ' VAPOR BARRIER Wz------- —�— Qe <- �a----�--�—, \/\/\/ 12"MIN �. d e \ \ \ \ \ FOOTING TO BEAR ON FIRM EXISTING FOUNDATION FACE w/ ° p — — — — — — — D #4 OR #5 UNDISTURBED SOIL 3 /\//\ //\/� / / (2) ROWS OF /611 DIA. TAPCONS / \\�\ OR CUT NAILS 24" O.C. COVER / D ° O co < . . REINFORCING PER FLUSH w/ 3000psi CONCRETE. . e / \ @ Q a , d MONOLITHIC FOOTING '\ d a SECTION 6" OPT. EXTENSION b D EXISTING FOUNDATION Q ' IN BRICK LOCATIONS • i °I I D D � -°e d �—e —<- a a e FOOTING TO BEAR ON FIRM ON FND PLAN \\ e_ UNDISTURBED SOIL 12" UNDER 1 STORY WALL W/ (2) ADDI da . MIN112" /\\/\\/\\/\\/\\/\\/\\ BAR I IN BRICK LEDGE NO. 5 #4 OR (2) #5 CONT �'\//\//\//\//\//\//\\ 16" UNDER 2 STORY WALL W/ (3) D e #4 OR (2) #5 CONT _ j\\ / ---= <--- \\ \\ \\ \\ \\ \\ \\ /\//\//\//\//\//\//\// /\//\//\//\//\/,\ ,�\ 1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH 8�� CMU WALL OVERHANGS 2.5�� OR LESS STEMWALL /�\ \\�\\/ STEMWALL FOOTING TO EXTEND MIN //\\ 12" BELOW MONOLITHIC FOOTING 'NOTE`': IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" NOTES: \ \ \\/�\,� • ADDITIONAL #4 OR #5 VERTICAL TO BE • IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, LOCATED WITHIN TRANSITION ZONE FTG DETAIL SPECIFIED ON THE FDN PLAN @ANY LOCATIONS THAT THE FTG LOCATE VERTICAL AND TIE INTO STEMWALL FOOTING DEPTH EXCEEDS 28". REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL REINFORCEMENT IN LAST REINFORCEMENT IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO STEMWALL CELL STEEPER THAN 1'-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. TWO CHOICES: • IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, 1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION CONTACT EOR. CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL OF SOIL. 2. USE STEMWALL FOOTING CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") v W1.4 x W1.4 WWF OR o FIBERMESH STUCCO OR DIRECTLY ADHERED STONE CLADDING FINISH - MIN 6" a) CD E ALL OTHER EXTERIOR WALL \\ \\ O \ \ \ \ o D CLADDING - MIN 8", U.N.O. ON ARCH VAPOR BARRIER \%\\ ° p \\\\\\\\/\\/� O �\ APES / 00 (1) O a)FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK 01 FIRM UNDISTURBED LOCATIONS ON FND PLAN m SOIL �— 12" UNDER 1 STORY WALL w/ N (2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 co BAR IN BRICK LEDGE J 16" UNDER 2 STORY WALL w/ LL (2) #5 OR (3) #4 CONTINUOUS W J tds -6 1 MONOLITHIC FOOTING SECTION j true design studies a CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Z > FOLLOWING OCCUR: O • OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U • GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U 9000 REGENCY SQUARE BLVD. FROM STRUCTURE STEEPER THAN 1'-O" VERTICALLY Q SUITE 100, JACKSONVILLE, FL 32211 PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. 0 O CONCRETE SLAB w/ 6x6 O (2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR f FIBERMESH W cy ~ CD 01,109ON" 'D Q L J / 16" VAPOR BARRIER w zzz Q � cy 3 BEARING WALL FOOTING SECTION z w CONCRETE SLAB W/ 6x6 0 W1.4 x W1.4 WWF OR W FIBERMESH w 0'-0" A.F.F. 0 SEE ARCH 0 DETAILS CF) a 8" MIN p 8"x8" THICKENED 8' ZFTG AT w STEP-DOWN, EE VAPOR BARRIER U) iiimm co /�/ PLAN w w CURB STEP SECTION ? Z W 4 000� o cn J _ 8" UNDER MASONRY WALL w W Z CONCRETE SLAB W/ 6" UNDER WOOD WALL 6x6 W1.4 x W1.4 WWF J�4 z / OR FIBERMESH VARIES SEE ARCH w W W Ly (MAX 16) — — — — — — d " a e � V w w /\/\ / / �/\�// / /\ O x 12" MIN. \\�\\�\\�\\�\� LJLLL X VAPOR BARRIER \// a a /�. /i / O Z H O 6" OPT. EXTENSION IN BRICK < 0 LOCATIONS ON FND PLAN O w 12" UNDER 1 STORY WALL w/ CL Z (2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 Ix O d BAR IN BRICK LEDGE U 16" UNDER 2 STORY WALL w/ LL (2) #5 OR (3) #4 CONTINUOUS Q � W Abbott Park Q 5 GARAGE_EXT WALL CURB SECTION O U CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE —1 (� FOLLOWING OCCUR: Q LOT 008-01 0 • OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" • GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U Q FROM STRUCTURE STEEPER THAN V-0" VERTICALLY Z Z PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. — 0 } CONCRETE SLAB W/ 6x6 0 PROJECT NO: w W1.4 x W1.4 WWF OR 0 0 FIBERMESH O 2021.003451 LL 0'-0" A.F.F. SEE ARCH Z DRAWN: O --d — — — 20" (MAX LDG ' a e d I DEEP) U cp Q-4 o d 41: CHKD: MJP X W w 4" EXTENSION Q Q UNDER BRICK VENEER X U Q `�tttit�tttr��� cn 12" UNDER 1 STORY WALL NO JN• LA&/ -' iO.- w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER 16" UNDER 2 STORY WALL 0 gg55 w/ (3) #4 OR (2) #5 CONT W bti§Wned ' - - — -- Z CURB STEP SECTION 0 *_B�RING �AF w — ---- - --- Z1� F43R.. TYPICAL REINFORCING zONA� BARS AT THICKENED QQ FOOTING, SEE PLAN 0 04-10-2019 Q MIN 24" LONG #4 OR #5 F- w BAR SET AT MID -DEPTH I'- (1) U OF SLAB, TYP ALL REVISIONS: w= RE-ENTRANT CORNERS � II Q No. Description Date W L--— — — — — — — J 1------------- _ 0 HOUSE SLAB 0 O O Z RE-ENTRANT CORNER DETAIL U 0 (RECOMMENDED) w PLAN VIEW, DETAIL TYPICAL @ ALL RE-ENTRANT CORNERS W ST=2D 11 Q CMU/METAL CONNECTOR ENGINEERING )ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 GENERAL MASONRY NOTES DC1 0 I in 0 ti 7' 1'-4" L 7' 6'-8" 4'-10" e 3'-8" ,, 4'-2" L-2 mi m 7'-0" 5'-8" 4'-8" 5'-10" 5'-4" 3'-8" f, 3'-2" 6'-8" 3'-8" 3'-8" 6'-8" ' L 7' 1st LEVEL STRUCTURAL PLAN 1/4" = 1'-0" WHEN PRINTED ON 22" 04" • ALL LINTELS SHALL BEAR A MINIMUM OF 4" AT EACH END. • 8U LINTELS MAY BE FILLED OR UNFILLED. • 8F LINTELS SHALL BE FILLED. • LINTELS MAY BE CAST-CRETE PRECAST LINTEL OR EQUAL. • DIMENSIONS ARE APPROXIMATE. MAX O.C. SPACING IS 6'-8" O.C., U.N.O. • SEE TYPICAL DETAILS FOR LINTEL INSTALLATION. • MASONRY LINTEL AS NOTED, SEE PLAN AND SCHEDULE • SPANS MAY VARY +/- 8" FOR ROUGH OPENINGS MASONRY LEGEND NOTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN [� INDICATES GROUT FILLED CELL WITH NO REINFORCING ■ NO. 5 BAR w/ VERTICAL BAR IN FILLED CELL W/ MINIMUM 30" LAP REQUIRED, TYP AS SHOWN Oo (2) NO. 5 BAR w/ VERTICAL BAR IN FILLED CELL W/ MINIMUM 30" LAP REQUIRED, TYP AS SHOWN ❑ OPT. NO. 5 BAR APPLIES ONLY IF OPT OPENING INSTALLED o❑ NO. 5 BAR w/ VERTICAL REINFORCEMENT AT CMU COLUMN AS SHOWN, HEIGHT OF DOWEL = HEIGHT OF COLUMN I-KAMINC3 KLY NU 1 Lb (I:MU) DC1 NOTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN (SEE SHEET ST-1 & 5 FOR TYPICAL NOTES) 1. MIN (2) INTERMEDIATE JACK STUDS REQUIRED BETWEEN OPENINGS. 2. SEE INTERIOR SHEARWALL DETAIL ON DETAIL SHEET. IN LOCATIONS WHERE INTERIOR SHEARWALLS HAVE VAULTED TOP PLATES, ALSO SEE INTERIOR SHEARWALL AT VAULTED TOP PLATE ON DETAIL SHEET. 3. ATTACH SW TO FLOOR DIAPHRAGM PER ONE OF THE FOLLOWING: A. IF FLOOR TRUSS ALIGNS ABOVE SW, ATTACH FLOOR TRUSS BOTTOM CHORD TO SW DBL TOP PLATE W/ 10d @ 3" O.C. B. FRAME AND SHEATH SW TO FLOOR DECK ABOVE. ATTACH FLOOR DECK TO SW DBL TOP PLATE W/ 10d @ 3" O.C. 4. HIGH UPLIFT CONNECTION: • FASTEN EVERY STUD TO TOP PLT w/ SP2 OR SDWC15600 @ MAX 16" O.0 • SECOND LEVEL WALL STUDS STRAPPED TO FIRST LEVEL WALL STUDS w/ MSTA36 OR CS18 @ MAX 48" O.C. (APPLICABLE ONLY w/ WOOD FRAMED FIRST LEVEL) FASTEN EVERY STUD TO BOTTOM PLT w/ SP 1 OR (2) SDWC15450 @ MAX 16" O.C. • TOP PLATE TO HDR W/ SDWC15600 @ MAX 16" O.C. 5, FASTEN EACH BEAM TO MASONRY W/ META12 U 0 N O N O O N u7 N 00 O O N N M J LL w J J z O U) Y U Q O O F w H U) 0 J m w Q U) U z w 0 w w O O O O L0 ti z 07 U) w Z_ U) m w w z Z w 0 0 J LL Z O i= Q O a_ 0 U Q 0 0 J LL Q U z } C� LINTEL SCHEDULE O J _ O LINTEL z LINTEL NO. MAX CLEAR OPENING FDESCRIPTION COMMENTS U w L-1 16'-0" 8F-1-32 GARAGE DOOR L-2 3'-0" ----8U8 L-3 6'-0" 8F-16 L-4 8'-0" 8F-16 SGD L-5 8'-8" 8F-16 REAR PORCH L-6 7'-0" 8F-16 REAR PORCH L-7 T-8" 8F-16 REAR PORCH L-8 1'4" 8F-16 FRONT PORCH L-9 4'4" 8F-8 T FRONT PORCH(ELEV A) L-9.1 4'-4" 8F-16 FRONT PORCH(ELEV B,E&F) L-10 6'-8" 8F-16 L WINDOW(ELEV F) F-- X w w Q X 0}0 LLJ `0 O Q z Z) O 1= U LL Q 07 O 0 O z T- o w 1— X w a- #--w-1 APEX 4 - tds true design studies N 9000 REGENCY SQUARE BLVD. SUITE 100, JACKSONVILLE, FL 32211 P� 0 U) W LL Z O W J —U) V � � Q O � Q W WLIJ V LJ W LL x Q z Z O 0 w Z a LL w Abbott Park Q U LOT 008-01 p w Q CD U) PROJECT NO: w 2021.003451 0 LL DRAWN: O LDG o CHKD: U') MJP U) w J Q U ,��� JS�C 1N Lq/vjF •,, c� `� �' � G•ENS '9 ��'� Z_ � y • U) 04-10-2019 p w REVISIONS: w 2 No. Description Date ~ w J — Q U _ U) 0 Z O 0 ST=3 CMU/METAL CONNECTOR ENGINEERING¢ :)ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 1st LEVEL FRAMING PLAN 1/4" = 1'-0" WHEN PRINTED ON 22"x34" tn% "-rA 40 40 r%M TRUSS FRAMING GENERAL NOTES SEE SHEET ST-1 & 5 FOR ADDITIONAL GENERAL NOTES • DRAFT STOPPING AT FLOOR TRUSSES TO BE PROVIDED BY BUILDER • UNLESS SPECIFICALLY NOTED ON TRUSS FRAMING PLAN, ALL TRUSS TO WOOD CONNECTIONS SHALL BE ACCORDING TO THE TYPICAL WALL SECTION, SEE SHEET ST-5. • REFER TO COMPONENT MANUFACTURER'S LAYOUT FOR TRUSS LABELS & DIMENSIONS OVERFRAMING NOTES • ALL RAFTERS TO BE MIN. 2x6 NO.2 SYP @ 24" O.C. MAX. • ALL "SLEEPERS" TO BE PLANK -ORIENTED 2x8 NO.2 SYP MIN. • FASTEN "SLEEPERS" TO EACH TRUSS/RAFTER W/ (3) 16d COMMONS MIN. • EACH RAFTER TO "SLEEPER" W/ SIMPSON H3 UPLIFT CONNECTOR. • ALL RIDGE BOARDS TO BE 2x8 NO.2 SYP MIN. • FASTEN 2x6 NO.2 SYP COLLAR TIES FROM RAFTER TO RAFTER WHERE APPLICABLE W/ (5) 10d COMMONS MIN. RAFTER SPAN SCHEDULE --- LUMBER SIZE SPACING __ 2x6 2x8 200 2x12 12" 15'-5" 19'-11" 23'-9" 26'4" 16" - _ 13'-4" 17'4" 20'-7" 22'-0" 24" 10'-11" 14'-1" 16-10" 19'-9" 20 L.L./15 D.L. #2 SYP CEILING JOIST SPAN SCHEDULE O.C. LUMBER SIZE SPACING 2x4 2x6 2x8 2x10 12" 12'-5" 19'-6" 25'-8" 26'-0" 16" 11'4" 17'-8" 23'4" 26'-0" 24" 9'-10" 15'-6" 20'-1" 2T-11" 10 L.L./5 D.L. #2 SYP TRUSS FRAMING KEY NOTES �OTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN 1 1. SEE "SHEAR PANEL" DETAIL ON DETAIL SHEET, 2. TYPICAL BEARING BLOCK • BEARING BLOCK TO BE NO.2 SYP, MIN 48" LONG AND TO MATCH DIMENSION OF TRUSS MEMBER. ATTACH BEARING BLOCK TO TRUSS VERTICAL OR TRUSS BOTTOM CHORD W/ (3) ROWS 1 Od @ 4" O.C. STAGGERED. 3. LEDGER FRAMING NOTES • FASTEN NO.2 SYP LEDGER TO FRAMING/TRUSS VERTICALS AT EVERY SUPPORT WITH FASTENING SHOWN BELOW (MAX 24" O.C. SPACING), OR • FASTEN NO.2 SYP PT LEDGER TO MASONRY/CONCRETE w/ FASTENING SHOWN BELOW • ADDITIONAL FASTENERS MAY BE REQUIRED AT SPECIFIED LOCATIONS ON PLAN • SEE TABLE 5 ON SHEET ST-1/S1 FOR FASTENER PROTECTION AGAINST CORROSION • EXTERIOR DECK LEDGERS SHALL BE SECURE TO WALL FRAMING WITH WOOD SCREWS. COMMON NAILS AT FLOOR LEDGERS ARE FOR INTERIOR USE ONLY. ROOF FRAMING LEDGER TO WOOD: 2x6...................................(4) 12d COMMON 2x8...................................(6) 12d COMMON 2x10.................................(8) 12d COMMON 2x12.................................(10) 12d COMMON LEDGER TO CMU (W/ 3" TAPCON OR TITEN): PT 2x6.......(2) ROWS %4' O @ 24" O.C. STAGGERED PT 2x8.......(2) ROWS %4" O @ 16" O.C. STAGGERED PT 2x10.....(2) ROWS %4" 0 @ 8" O.C. STAGGERED PT 2x12.....(2) ROWS %4" 0 @ 6" O.C. STAGGERED FLOOR FRAMING LEDGER TO WOOD (WI NAILS): 2x6...................................(3) 16d COMMON 2x8...................................(5) 16d COMMON 2x10.................................(7) 16d COMMON 2x12.................................(9) 16d COMMON FLOOR FRAMING LEDGER TO WOOD (W/ SCREWS): PT 2x6...................................(3) 'W x 4-%" LONG #14 WOOD SCREWS PT 2x8...................................(5) 'W x 4-'/V LONG #14 WOOD SCREWS PT 2x10.................................(7) 'W x 4-%" LONG #14 WOOD SCREWS PT 2x12.................................(9) W x 4-Y2' LONG #14 WOOD SCREWS 4. ANGLE & LATERAL BRACES MAYBE OMITTED FROM GABLE BRACING DETAIL IF PORCH SHEATHING DETAIL IS PROPERLY APPLIED, SEE DETAIL SHEET ST-6/7. 5. IF USING (2) HTWM20, INSTALL (1) STRAP ON EACH FACE OF THE WALL - (2) HTWM20 ON SAME SIDE OF WALL IS NOT i PERMITTED AT THIS LOCATION ZD U 0 C6 Ern N I� a O cy O 0 APEX N , t>3 N N co Zz -J , U_ W tds J J-6 true design studios Z > O U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 _p O O W C OsRsHOMON' J o +� m W Q :D V � U Z W W w O O O O ti zIT ti O 0 c) Z LU U) IIIIIIIIIIm W ZLL z _ U) LU J O co m w W V Q w O Z > Q Q Z W LU LLJ o cr_(0)Lv LU O x LL LL Z z _O Z H 0 a o IY W 0- z Of O a Q W � J Abbott Park Q O U J (n w LOT 008-01 p Q w U Q Z z t} U) v PROJECT NO: w 6. • (1) 48" & (1) 24" BEARING BLOCK REQ'D OJ 2021.003451 • EACH BLOCK TO TRUSS W/ (3) ROWS 10d @ 4" O.C. O LL STAGGEREDZ DRAWN: O • TRUSS TO MASONRY BELOW W/ LGT3-SDS2.5 U LDG o O wCHKD: L0 MJP x w w U `41%ji111###t, U)} IN Lq/V/, U) �• 'DENS' •'� �. 00 ww = oMgOned; Q Z - = cn Q •' •31� F43C.. Z 9/(AN'{{E,���` 3 � QQ 0 04-10-2019 Q F= w U REVISIONS: Q No. Description Date w (n J -- Q } U C� U) O O O Z = 0 w F- x w ST=3A a- CMU/METAL CONNECTOR ENGINEERING¢ )ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 TYPICAL ROOF DECK U SHEATHING. SEE TABLE 2: 2x NO 2 SYP BLOCKING TO FIT TIGHT WOOD STRUCTURAL PANEL BETWEEN TRUSSES, (3)10d TOE -NAIL @ > SHEATHING REQUIREMENTS EACH END, BLOCKING MAY BE OMITTED a ON SHEET ST-1. FOR HEEL HEIGHTS < 9" — — — — — — N TRUSS OR RAFTER TO BOND 3/4" BETWEEN TOP OF WOOD PANEL FOR MISLOCATION tie"<X<1 Y�" � FASTEN 2x6 NO. 2 SYP SHIM #5 CONT. — BEAM W/ META12 OR w c AND CENTER OF FASTENERS. TO TRUSS W/ MIN (10) 10d HTA16-18 W/ MIN (7) 10d x 1%" w (1) #5 BAR CONT. IN TRUSS (NOTE: IF META12 g MIN 1%2' EXPOSURE 1 PLYWOOD RIM @ RAISED FOR MISLOCATION 1�" <X OR HTA16-18 IS IMPROPERLY w HEEL TRUSSES INSTALLED WITH LONG INSTALL NEW MASONRY TWIST INSTALLED, ATTACH TRUSS Q DIMENSION PERPENDICULAR TO TRUSS END STRAP TO INSIDE F CE TO BOND BEAM W/ HTSM20 VERTICALS, ATTACH TO TRUSSES AND o (1) #4 OR #5 BAR AT CORNERS /• OR HTWM20) BLOCKING W/ 1Od @ 3" O.C. Z WITH MIN. 25" LAPLI ✓ . FASCIA ARCHITECTURAL) — — —_ (SEE #5 CONT. TRUSS TO TOP PLATE FASCIA (SEE PROPERLY WIND LOAD RATED SOFFIT MATERIAL CONTINUOUS @ PERIMETER. I W/ H2.5T OR RT7AT ARCHITECTURAL) MOISTURE BARRIER BY �' SEE DESIGN CRITERIA AND LOADS: C&C1. .• , V OR SDWC15600, UNO MOISTURE BARRIER • C OTHERS DESIGN PRESSURES ON SHEET ST-1. '4 o ON PLAN BETWEEN MASONRY AND PROPERLY WIND LOAD RATED TRUSS OR RAFTER TO BOND BEAM W/ v v NON -PT LUMBER BY OTHERS SOFFIT MATERIAL (1) COURSE META12 OR HTA16-18 W/ MIN (7) 10d x o VERT. REINFORCING TO CONTINUOUS @ PERIMETER. CMU BOND , 1 /�f IN TRUSS (NOTE: IF META12 OR 8" CMU BOND BEAM HAVE 10" STANDARD SEE TABLE 1: COMPONENT BEAM W/ #5 HTA16-18 IS IMPROPERLY INSTALLED, POURED CELL w #5 BAR CONT. HOOK INTO BOND BEAM AND CLADDING DESIGN \_(1)COURSECMUBOND CONTINUOUS ATTACH TRUSS TO BOND BEAM W/ FROM BEAM TO FOOTING i PRESSURES ON SHEET ST-1. HTSM20 OR HTWM20) i I MISLOCATED TRUSS ANCHORS BOND BEAM REINFORCING STEP DOWN TIE -BEAM • EVERY OTHER STUD TO TOP PLATE W/SP2 OR SPT24 OR SDWC15600 - BEAM W/ #5 CONTINUOUS , BLOCKING NOT SHOWN FOR CLARITY AT CORNERS MAX 32" O.C. • EVERY KING STUD TO TOP PLATE W/ SP2 OR SPT24 OR SDWC15600 WALL SECTION AT ROOF (COMMON HEEL CONDITION) (THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) • EVERY OTHER STUD TO BOTTOM PLATE W/ SP1 OR SPT22 OR SDWC15450 • EVERY KING STUD TO BOTTOM PLATE W/ SP1 OR SPT22 OR SDWC15450 2x_ NO. SPF OR BETTER @ MAX 16" O.C. '/z' THREADED ROD ANCHOR W/ MIN 4" EMBED W/ NUT & WASHER IN SIMPSON ACRYLIC -TIE OR EQUIVALENT ADHESIVE @ MAX 48" O.C. OR %" WEDGE BOLT W/ MIN 4Y2" EMBED W/ WASHER @ MAX 48" O.C. BOTTOM PLATE ANCHOR NOTES ■ EACH SILL PLATE SHALL HAVE A MIN. OF (2) BOTTOM PLATE ANCHORS. ■ INSTALL ANCHORS WITHIN 12" OF EACH END OF SEGMENT (BUTT JOINTS). INTERIOR LOAD BEARING WALL EXTERIOR WALL TYPICAL WALL SECTION AT FOUNDATION (THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) 8" PARTIALLY GROUTED EXTERIOR CMU WALL W/ VERTICAL WALL REINFORCING PER STRUCTURAL PLAN, SHEET ST-3 OR ST-2A (IF APPLICABLE) PROVIDE DOWELS TO MATCH VERTICAL WALL REINFORCING W/ MIN 30" LAP (IF DOWEL IS OMITTED OR IMPROPERLY INSTALLED, DRILL AND EPDXY DOWEL OF EQUAL SIZE W/ MIN. 6" EMBEDMENT IN MONOLITHIC, 12" EMBEDMENT IN MASONRY) WALL SECTION AT ROOF (RAISED HEEL CONDITION) THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS GENERAL NOTES APPLICABLE TO ALL: ALTERNATE WALL SECTIONS & TYPICAL DETAILS 1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM (20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. 2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. 3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. 4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. 5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. 6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. 7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A 8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. 9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. DIST. FROM DOOR JAMB / WINDOW TO BLOCK MIN. SCREW DIST. FROM DOOR JAMB LENGTH i WINDOW TO BLOCK MIN. SCREW LENGTH OR 1%4" PER MANUF. 3" 5" 11/y 3 %4'f 3 746 51, 115/6 33/4, 33/„ 6" 2 %4' 33/4" TYPICAL DOORMINDOW JAMB TO BLOCK (TYPICAL FOR ALL MASONRY OPENINGS, UNO) O U O cr O 0 APEX co N O N O N co Jtds •, LL � W J Q J true design sfudios a)> z > O U) U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 ui 0 O O r- W 04ROHOM0 > ,il w Q � N Z W (D W tr O O O O LO z ti O p Z LU U)00 _ w W Z_ m ..I O c/) w w Q w z 0 � 0 Q W m w w W V LLJ LU O J x U_ ILL z O � Q 0 d z O a U LL 00 W of Abbott Park Q O U J (n IL LOT 008-01 0 Q w U Q Z_ Z } 0 C� w O PROJECT NO: w J 2021.003451 O u- Z DRAWN: O U LDG o LO � CHKD. MJP U) x w w U Q ,���w►rirrrrr�� cn i1N LA/U�� }' �� �. CENS• •9 '. co• �,� F • Z �w = oOne d•t�y_ Q z rl f # ..3 _ N Ow'F.... ........ ' I < •' 6fp. tF43�.. Q O 04-10-2019 p F- w U_ REVISIONS: U_ F- No. Description Date W (n J Q � U O O O Z Z U r) w x w ST=5 a Q CMU/META' CONNECTOR ENGINEERING OocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 BLOCK PANEL EDGES WITHIN 4'4' OF GABLE TRUSS (EDGEWISE FASTEN ROOF DECK TO OR FLATWISE) FRAMING @ 3" O.C. ON TOE -NAIL MIN 2x4 NO.2 SYP BLOCKING EDGE, 6" O.C. IN FIELD BETWEEN TRUSS TOP CHORDS W/ WITH RSRS-01 (3) 10d COMM NS EACH END ROOF DECK—\ — 2x4 SYP OUTRIGGER @ 24" O.C. CLIP TO GABLE TOP CHORD WITH (1) H2.5T w/ (10) 8d x 1 %" 2x4 NO.2 SYP BLOCKING BETWEEN PROVIDE PANEL OUTLOOKERS. FASTEN EACH EDGE BLOCKING FOR BLOCK TO ROOF DECK WITH 8d NON -DROPPED GABLE COMMON @ 3" O.C. FASTEN 2x6 NO.2 SYP DIAGONAL BRACE TO BLOCKING w/ (6) GABLE TRUSS 10d COMMONS 2x6 NO.2 SYP DIAGONAL BRACi SEE PLAN WALL SHEATHING PER PLAN • UP TO 8FT SINGLE 2x6 ONLY • UP TO 20 FT, 2x6 W/ 2x6 T-BRACE rl L OR T BRACE VERTICAL REINFORCEMENT PER TRUSS ENGINEERING FASTEN 2x6 N0.2 SYP "T-BRACE" TO DIAGONAL BRACE w/ 1 Od COMMONS @ 3' O.C. MOISTURE BARRIER SHALL BE 8'4' OR AS SHOWN ON PLAN PROVIDED BETWEEN MASONRY AND ALL UNTREATED LUMBER GABLE TRUSS TO BOND BEAM W/ META20 @ 48" O.C. W/ MIN (7) 10d x 1 '/z' (NOTE: IF META20 IS IMPROPERLY INSTALLED, ATTACH TRUSS TO BOND FASTEN (1) SIMPSON HGAM10 BRACE CONNECTOR BEAM W/ HTSM20 OR MSTAM36) FROM DIAGONAL BRACE TO CMU MOISTURE BARRIER BETWEEN MASONRY AND NON -PT LUMBER BY OTHERS GABLE�ANG�LEETAIL ) (W/ HGAV20221 B3 T.C.O 1.0 1) MAX. TRUS4" 2) OUTLOOKERS, BLOCKING & CLIPS MAY BE OMITTED FROM OVERHANG PORTION OF DETAIL FOR NON -DROPPED GABLE TRUSSES W/ 9" OR LESS OVERHANGS. ROOF DECK ROOFTRUSS OR RAFTER UPLIFT CONNECTION PER TYPICAL WALL SECTION i• SUB FASCIA MOISTURE BARRIER TYPICAL PORCH BY OTHERS CEILING BOARD PER PLAN. SEE TABLE 2; MOISTURE BARRIER SHEET ST-1 (PORCH BY OTHERS CEILING BOARD) MASONRY LINTEL PER PLAN TYPICAL PORCH SHEATHING DETAIL AT MASONRY EXTERIOR WALL (THIS DETAIL IS REQUIRED AT ALL COVERED PORCHES UNLESS NOTED OTHERWISE) 7.9 F.F.E. .F.E. F.F.. TOP OF q_OF OPENING 2x6x12 I CENTEI 6-1"ABOV� F.F.E. 48' DIA. ANCHOI F. F. ABOVE F.F.E. 2'-9" ABOVE F.F.E. 0'-9" ABOVE F.F.E. TOP OF CURB F.F.E. 2x4 PT TOP 2x6 PT BUCK EACH SIDE OF OPENING PROVIDE (5) 48' DIA. J-BOLT OR LARGE DIAMETER SCREW ANCHOR w/ 5 %" EMBEDMENT AT EACH DOOR BRACKET, EACH SIDE OF DOOR. PROVIDE 1 '/V x 41s' THICK WASHER w/ EACH ANCHOR. (1st BOLT TO BE 9" MAX. ABOVE CURB.) GARAGE DOOR JAMB DETAIL BOND BEAM BOND BE REINFORCEMENT REINFOR MENT J (SEE WALL SECTION) J (SEE WAL ECTION) PRE -CAST LINTEL #5 CONT. PER PLAN = FILL SOLID TO BOND BEAM w FILL SOLID TO BOND BEAM a (1) #5 BAR AT CORNERLO g w w W/ MIN. 25" LAP N ai ui Z LINTEL REINFORCEMENT #5 CONT. Y = • wo v 0 0 0 0 8 F - #•—*— DEPTH OF LINTEL 8 F -1 #�—DEPTH OF LINTEL ASSEMBLY "d" o � FILL BOTH LINTELS SOLID ASSEMBLY "d„ - W/ CONTINUOUS POUR GROUT FILLED LINTEL ASSEMBLY #5 BOTTOM BAR TO EXTEND 1 17 o NO LESS THAN 1" BEYOND 8" PRECAST LINTEL. SEE PLAN. BEARING AT EACH END GROUT FILLED LINTEL ASSEMBLY PRE -CAST LINTEL PER PLAN MITER -CUT LINTELS AT CORNER, 8" PRECAST LINTEL. SEE PLAN. CORNER TO BE TEMPORARILY SHORED FOR MIN (7) DAYS 8F-# 8F-1-# LINTEL REINFORCING AT CORNER BOND BEAM REINFORCEMENT (SEE WALL SECTION) COURSING BELOW BOND BEAM MAY BE FILLED OR " UNFILLED sus LINTEL MAY BE FILLED OR UNFILLED 8" PRECAST LINTEL. SEE PLAN. 8U8 TYPICAL PRE -CAST LINTEL OPTIONS O U O CY O 0 APEX 0 U N O tll � t6 N N co LJL J tds J-6 N true design studios > Z O 0 U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 —� 0 O � o 4- LATERAL BRACING - MULTIPLE TRUSSES w 1. ALL RESTRAINT LUMBER SHOWN SHALL BE 2x4 NO.3 SPF OR BETTER (UNO). 2. SHOULD A SCENARIO ARISE THAT DOES NOT RESEMBLE THOSE INDICATED ABOVE, IMMEDIATELY D CONTACT THE ENGINEER OF RECORD FOR APPROPRIATE BRACING DETAILS. 04HIHOMON a) 3" BRACING LUMBER SHALL INTERSECT THE WEBS OF THE BRACED TRUSS AT LOCATIONS INDICATED AS p L_ NEEDING BRACING ON THE INDIVIDUAL TRUSS DETAILS PRODUCED BY THE TRUSS ENGINEER. J 4. ALL FASTENERS SHOWN ARE. 131" x 3" LONG (UNO). m 5. DESIGNED PER BCSI-B3, MOST CURRENT EDITION. W Z) a -T6" MAX _" MAX =" MAX T" MAX =" MAX �" MAX TRUSSES NEEDING BRACING 0 Z W W O O O O ti ti SINGLE TRUSS BRACING b Q Z W 1. INDIVIDUAL WEB BRACING MAY BE USED WHEN CONTINUOUS LATERAL RESTRAINT (CLR) IS SPECIFIED ON A TRUSS DESIGN BUT AN U) ALTERNATIVE WEB BRACING METHOD IS DESIRED. Z 2. INDIVIDUAL WEB BRACING MAY CONSIST OF T-BRACING, L-BRACING, OR _ SCAB BRACING. REFER TO CHART AND DETAIL FOR MORE INFORMATION. U) W 3. INDIVIDUAL WEB BRACING MATERIAL TO BE SAME SIZE, SPECIES, AND O GRADE AS WEB TO BE BRACED. m li w V Q w 0 VERTICAL BARS TO EXTEND TO Z TOP OF WALL AS SHOWN. MIN 3 > Q " 6BEND INTO BOND BEAM - W m w w w _ a 2 V w w O � - _j X LL ZO a Z I 1- O Q p I � W I1 Z - -------------------------- - O 1 U LL Q Abbott Park Q O U PRECAST LINTEL SEE J co PLAN Q LOT 008-01 W I EXTEND REINFORCING TO Z Z END OF PIER W/ 6" BEND TO LAP WALL REINFORCING AS } SHOWN. I I I O PROJECT NO: w MIN (2) SOLID FILLED & -J 2021.003451 I REINFORCED CELLS W/, NO.5 0 _ VERT. BAR ADJACENT TO z DRAWN - - GARAGE DOOR OPENINGS. U LDG o NO.5 VERT. BAR IN FILLED CHKD: U) CELL AT EACH END OF PIER x MJP \ LU J NO. 5 DOWEL TO MATCH EACH Q Q SOLID FILLED & REINFORCED X V !, CELL EXTENDING FROM FOOTING < NN%�cjjm,N Lq TO LAP WALL REINFORCING W/ MIN 25" LAP UNLESS NOTED } ��% �J '• � G E N OTHERWISE ON DOWEL & LINTEL m •'�•`sF I Z �I PLACEMENT PLAN. MIN 6" BEND 0 AT BOTTOM. w -C""\, 0�amfinea Q Z- - CONCRETE O- FOUNDATION WORK w 44/ U) TOP OF FINISH PER PLAN P •' � -z' (D FLOOR SLAB . t� :iWVtF43�.. Z����&/0 N A �� � II (n /11111 p 04-10-2019 p ---------------------------- — \ i � � W \ ' U REVISIONS: _ x I I Da te ti i D N Q o. Description ae ~ �\ ---- - w o ° GARAGE SHEAR PIER = o U � w H X w 5T=6 n. CMU/METAL CONNECTOR ENGINEERING T-BRACE FASTENED TO WEB W/ 1 Od AT 6" O.C. L-BRACE FASTENED TO WEB W/ 1 Od AT 6" O.C. SCAB BRACE FASTENED TO WEB W/ 1 Od AT 6" O.C. *IF (2) BRACES ARE REQUIRED, APPLY (1) BRACE TO EACH FACE OF WEB. TOP OF WALL SEE LATERAL RESTRAINT WEB CONTINUOUS BRACE SUBSTITUTE WEB MEMBER ALTERNATE BRACING SIZE LPECIFIED CLR T OR L SCAB 2x4 1 ROW 2x4 (1)2x4 2x4 2 ROWS 2x6 (2)2x4* 2x6 1 ROW 2x4 (1)2x6 2x6 2 ROWS 2x6 (2)2x4* 2x8 1 ROW 2x6 (1)2x8 2x8 2 ROWS 2x6 (2)2x6*