Loading...
HomeMy WebLinkAbout8249 Wheat Stone DrDocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 I 1 I I 1 1 I- l _1__L it DRAWING INDEX ARCHITECTURAL SHEET NO. I SHEET NAME A000 ARCHITECTURAL GENERAL NOTES A110 1 st LEVEL FLOOR PLAN A200 ELEVATIONS A400 WALL SECTIONS A500 DETAILS A501 DETAILS A502 DETAILS - IF APPLICABLE STRUCTURAL SHEET NO. I SHEET NAME ST-1 STRUCTURAL SPECIFICATIONS ST-2 FOUNDATION PLAN ST-2.D FOUNDATION DETAILS ST-3 1 st LEVEL STRUCTURAL PLAN ST-3A 1st LEVEL FRAMING PLAN ST-5 TYPICAL WALL SECTIONS ST-6 SECTIONS AND DETAILS 0 Cal [Lolftfs A4DB DELRAY ELEVATION A ABBOTT PARK, LOT 04OmO3 ELECTRICAL SHEET NO. I SHEET NAME E100 1st LEVEL ELECTRICAL PLAN BUILDING CODE SUMMARY THE PROJECT SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES FL BUILDING CODE - RESIDENTIAL: 2020 FL BUILDING CODE - FUEL GAS: 2020 FL BUILDING CODE - PLUMBING: 2020 NATIONAL ELECTRIC CODE: 2017 FL BUILDING CODE - MECHANICAL: 2020 FL FIRE PREVENTION CODE: 2020 FL BUILDING CODE - ENERGY CONSERVATION: 2020 OCCUPANCY CLASSIFICATION: RESIDENTIAL CONSTRUCTION TYPE: VB WIND ZONE: SEE ST-1 SPRINKLED: NO ZONING CODE: PROPOSED STRUCTURE COMPLIES WITH THE REQUIREMENTS OF CHAPTER 656, ZONING CODE FOR RESIDENTIAL DISTRICTS, INCL MAX BLDG HGT OF 35' AREAS VOLUMES 'CONDITIONED AREA 118982 CF 1st Floor 2034 SIF l'i Grand total 18982 CF 2034 SF ,-UNCONDITIONED AREA Garage 459 SF Entry 28 SF Lanai 218 SF i 705 SF Grand total 12739 SF C3 U O O O co APEX CD a) N u- W tds -16 J J_ y \ �r.F:.. .. esign SLR.:ii1i. s D z O U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 vn p O O _73 W 00 RRHOMN' 7 00 rili "'it tk ?III' J ar w 0 (Y U) z w w IY O O O O ti ti b V J z w U) Q w ry z w m Lju O cnw1E w w z > o w m w w 0 oLLJ ® J w w O �• z Q ILL u X O z I-= O 0 0Y w O �- Iz z U u- a w ABBOTT PARK Q O U u- LOT 040-03 0 Q w U Q z z CD PROJECT NO w O 2021.006629 O w z DRAWN O U KME o fw' CHKD: LO JAC co x w w � U X co z_ 0 w Q z _ � 0 O w U) Q z z O_ 05-18-2021 p H w U_ REVISIONS: ILL -- No. Description Date w U) J U) O O 0 O jU 0 w X w 0000 IZ Q )ocuSign Envelope ID: 804C66C7-lA16-44B1-A7C7-0002ED72E2B6 Footer ; Re -Bar (sized according to foundation plan) e #4 awg CU bare w/ 10' stubbed , outside of slab at service q location. Connect to footer steel E0 w/ (2) ground clamps 5' apart LIFER GROUND DETAIL N.T.S. ELECTRICAL RISER DIAGRAM OPTIONAL OVERHEAD SERVICE SAME AS 150 = #1 Copper or 2/ 0 Aluminum UNDERGROUND 150 OR 200 200 = 2 /0 Copper or 4 /0 Aluminum in 2" AMP SERVICE i Conduit. A/C DISCONNECT METER MAIN Dlsc #12 COPPER TO APPLIANCES AND GFI 150 OR 200 AMP TYPICAL ELECTRICAL -_ #14 COPPER TO LIGHTS AND OUTLETS PANELUNDG#10 COPPER TO WATER HEATER #8 COPPER TO RANGE SERV. BY ERV. B POWER CO. #6 COPPER TO HVAC N.T.S. #4 GROUNDING WIRE WITH CODE APPROVED CLAMP TO EITHER: -_ A) APPROVED GROUNDING ROD WITH MINIMUM 8' DEPTH B) BONDED TO CONTINUOUS FOOTING STEEL INTERSYSTEM BONDING TERMINATION PER NEC 250.94 NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY GENERAL ELECTRICAL NOTES ALL ELECTRICAL DESIGN AND WORK SHALL BE IN STRICT COMPLIANCE WITH THE 2017 NATIONAL ELECTRIC CODE • PER NEC SECTION 210.12 (B) ALL 15A & 20A, 120V BRANCH CIRCUITS SUPPLYING OUTLETS REQUIRE AFCI PROTECTION • CARBON MONOXIDE PROTECTION PER FLORIDA STATUTES 553.885 (2). TO BE INSTALLED WITHIN 10' OF EVERY SLEEPING ROOM • ALL OUTLETS SHOULD BE AFCI PER NEC - U.N.O. • PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V RECEPTACLES INSTALLED OUTDOORS MUST BE GFCI-PROTECTED • PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V RECEPTACLES INSTALLED WITHIN 6' OF SINK (IN NON -DWELLING OCCUPANCIES-i.e. OUTDOOR SUMMER KITCHENS RECEPTACLES) MUST BE GFCI-PROTECTED • PER NEC SECTION 406.8(6)(1) 15A & 20A RECEPTACLES IN A WET LOCATION MUST BE WITHIN AN ENCLOSURE THAT IS WEATHERPROOF WHEN AN ATTACHMENT IS PLUGGED IN AN ALL NON -LOCKING RECEPTACLES SHALL BE LISTED AS WEATHER RESISTANT • PER NEC SECTION 406.11 IN DWELLING UNITS, ALL 15A & 20A, 15V RECEPTACLES SHALL BE LISTED AS TAMPER -RESISTANT • PER NEC SECTION 800.156 NO LESS THAN ONE COMMUNICATION OUTLET SHALL BE INSTALLED WITHIN EACH DWELLING UNIT • PER NEC SECTION R314.3 AND R315.1 SMOKE DETECTORS TO BE INSTALLED INSIDE EACH SLEEPING AREA • ALL SMOKE ALARMS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 217, PER FBC 314.1. GC TO INSTALL; KIDDE MODEL # 14618A SMOKE ALARM, OR APPROVED EQUAL • PROVIDE GAS DROPS AS PER COMMUNITY ONLY • JUNCTION BOX AT WATER HEATER, RANGE AND/OR DRYER TO BE 220V IN NON GAS COMMUNITIES, AND 110V IN COMMUNITIES THAT HAVE GAS OPTIONS PROVIDE APPROPRIATE RECEPTACLE PER APPLIANCE • ALL LAMPS SHALL BE HIGH -EFFICACY TO COMPLY WITH FBC-EC R404.1 - (LOW -VOLTAGE LAMPS EXCLUDED). • PER FBC-R M1305.1 A LEVEL WORKING SPACE NOT LESS THAN 30" DEEP AND 30" WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE OF ANY APPLIANCE ABBREVIATIONS LEGEND ABV ABOVE AC AIR CONDITIONER AFF ABOVE FINISHED FLOOR AHU AIR HANDLER UNIT BLK BLOCK CABS CABINETS CLG CEILING CHR CHAIR RAIL COFF COFFERED COL COLUMN COND CONDENSER CRN CROWN MOULDING CVAC CENTRAL VACUUM SYSTEM DBL DOUBLE DIAG DIAGONAL DR DOOR DRY DRYER DW DISHWASHER EB EYEBROW FL FLOOR LINE (MAT. CHANGE) FLR FLOOR FP FIREPLACE FXD FIXED FXT FIXTURE GLS GLASS HB HOSE BIB KS KNEE SPACE LAV LAVATORY LT LAUNDRY TUB MRBL MARBLE MC MEDICINE CABINET MIR MIRROR MTL METAL OH OVERHEAD OPNG OPENING OPT OPTIONAL R & S CLOTHES ROD and SHELF REF REFRIGERATOR SD SOAP DISH SDLTS SIDE LIGHTS SGD SLIDING GLASS DOOR SH (2) SHELVES (QUANTITY) SHWR SHOWER TB TOWEL BAR TPH TOILET PAPER HOLDER T&S TUB and SHOWER TEMP TEMPERED TR TRANSOM VOL VOLUME WC WATER CLOSET WD WOOD WH WATER HEATER WNCT WAINSCOT WS WATER SOFTENER WASH WASHER ROOF NOTES • INSTALL ROOF VENTING PER MFR WRITTEN INSTRUCTIONS PER FBC R806 • ALL OVERHANG DIMENSIONS ARE TO EDGE OF RAFTER. REFERENCE WALL SECTIONS/DETAILS FOR ALL OVERHANGS NOT DIMENSIONED. • ALL UNDERLAYMENT MUST BE INSTALLED IN COMPLIANCE WITH FBC R905.1.1 • EACH 4' OFF RIDGE VENT REQUIRES (1) 46" x 3" CUT OUT IN ROOF SHEATHING PER MFR WRITTEN INSTRUCTIONS ROOF VENT CALCULATION FORMULA: 1 SQUARE INCH VENT FOR EVERY 300 SQUARE INCHES OF CEILING *144 SQ. IN. = 1 SQ. FT. BLDG. CEILING (SF) x 144 = BLDG (SQ. IN.) BLDG. (SQ. IN.) / 300 = SQ. IN. OF VENT REQUIRED SQ. IN. OF VENT REQUIRED / 2 = 50% AT HIGH AND 50% AT LOW. PER FBC SECTION R806.2: 40% MIN, BUT NOT MORE THAN 50% OF VENTILATION MUST BE PROVIDED BY VENTILATORS LOCATED NO MORE THAN 3-0" BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE BASIS OF CALCULATION: ("OR EQUAL" ACCEPTABLE) (a) OFF RIDGE VENTS - STAMPCO W/ 36 SQ IN (NFVA) PER LINEAL FT (b) SOFFIT VENTS - GP T3-1/3" FULL VENT PERFORATED W/ 9.19 SQ IN (NFVA) PER LINEAL FT CALCULATED LINEAL FOOT OF SOFFIT VENT SHALL NOT INCLUDE NON -VENTED FIRE RATED SOFFIT LOCATED LESS THAN S FROM PROPERTY LINE EXTERIOR ELEVATION GENERAL NOTES GENERAL NOTES • FRONT ELEVATIONS BANDING, MOLDING, • ALL CONSTRUCTION SHALL MEET THE LATEST COLUMNS AND TRIM SHALL RECEIVE A SAND EDITION OF CODES ADOPTED BY THE LOCAL FINISH, SEE ELEVATION FOR DEPTH OR RAISED GOVERNING AGENCIES BANDING • SIDE AND REAR ELEVATIONS BANDING AROUND • PER FBC R302.5 NO OPENINGS FROM A PRIVATE WINDOWS AND DOORS MAY BE OPTIONAL PER GARAGE ARE PERMITTED DIRECTLY INTO SLEEPING COMMUNITY SPECS - SEE COMMUNITY AREAS. ALL OPENINGS SHALL HAVE SOLID WOOD, SPECIFICATIONS OR CONSULT THE INSULATED STEEL OR 20 MIN. FIRE RATED DOORS CONSTRUCTION MANAGER. ALL BANDING SHALL NOT LESS THAN 1-3/8 INCHES THICKNESS, EQUIPPED RECEIVE A SAND FINISH WITH A SELF CLOSING DEVICE. ALL DUCTS IN THE GARAGE OR PENETRATING THE WALL OR CEILING • ROOF COVERING SEE COMMUNITY SEPARATING THE GARAGE AND DWELLING SHALL BE SPECIFICATIONS OR CONSULT THE CONSTRUCTION MANAGER. SEE STRUCTURAL CONSTRUCTED OF MIN. 26 GA. SHEET METAL, 1 INCH SHEETS FOR SHEATHING REQUIREMENTS MINIMUM RIGID CLASS 0 OR 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO • FLASHING SHALL BE INSTALLED AT WALL AND OPENINGS INTO THE GARAGE ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN • PER FBC TABLE R-302.6 GARAGE SHALL BE ROOF SLOPE OR DIRECTION, AND AROUND ROOF SEPARATED FROM RESIDENCE AND ITS ATTIC W/ OPENINGS MIN. 1/2'' GYP BOARD ATTACHED IN ACCORDANCE • WINDOW PAN FLASHING SHALL BE IN WITH TABLE R702.3.5. HABITABLE ROOMS SHALL BE ACCORDANCE WITH FBC R703.4 SEPARATED FROM ROOM ABOVE W/ MIN 5/8" TYPE "X" GYP BOARD, WHERE THE SEPARATION IS A • WALL HEIGHTS VERIFY ALL BEARING WALL FLOOR -CEILING ASSEMBLY. ANY STRUCTURE HEIGHTS WITH FINAL TRUSS LAYOUTS SUPPORTING THE ASSEMBLY SHALL BE PROTECTED W/ MIN 1/2" GYP BOARD • LATH PER FBC R703.7.1, LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. EXPANDED • PER FBC R-312.1 PORCHES, BALCONIES OR RAISED METAL OR WOVEN WIRE LATH SHALL BE FLOOR SURFACES LOCATED MORE THAN 30" ABOVE ATTACHED WITH 11/2-INCH-LONG (38 MM), 11 GAGE FINISHED FLOOR OR GRADE SHALL HAVE GUARDS NAILS HAVING A 7/16-INCH (11.1 MM) HEAD, OR NOT LESS THAN 36" IN HEIGHT. PER FBC R-312.1.2 7/8-INCHLONG (22.2 MM), 16 GAGE STAPLES, OPEN SIDES OF STAIRS WITH A TOTAL RISE OF SPACED NOT MORE THAN 6 INCHES (152 MM), OR MORE THAN 30" ABOVE FINISHED FLOOR OR GRADE AS OTHERWISE APPROVED SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT • PLASTER PER R703.7.2, PLASTERING WITH MEASURED VERTICALLY FROM THE NOSING OF THE PORTLAND CEMENT PLASTER SHALL BE NOT LESS TREADS THAN THREE COATS WHERE APPLIED OVER METAL LATH OR WIRE LATH AND SHALL BE NOT LESS • PER FBC R-312.1.3 REQUIRED GUARDS ON OPEN THAN TWO COATS WHERE APPLIED OVER SIDES OF STAIRWAYS, RAISED FLOOR AREAS, MASONRY, CONCRETE, PRESSURE -PRESERVATIVE BALCONIES AND PORCHES SHALL HAVE TREATED WOOD OR DECAY -RESISTANT WOOD AS INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SPECIFIED IN SECTION R317.1 OR GYPSUM BACKING. IF THE PLASTER SURFACE IS WHICH DO NOT ALLOW PASSAGE OF A SPHERE 4" COMPLETELY COVERED BY VENEER OR OTHER OR MORE IN DIAMETER FACING MATERIAL OR IS COMPLETELY CONCEALED, PLASTER APPLICATION NEED BE • PER FBC R-308.4.5 GLAZING IN WALLS, ENCLOSURES ONLY TWO COATS, PROVIDED THE TOTAL OR FENCES CONTAINING OR FACING HOT TUBS, THICKNESS IS AS SET FORTH IN TABLE R702.1(1). SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, ON WOOD -FRAME CONSTRUCTION WITH AN ON -GRADE FLOOR SLAB SYSTEM, EXTERIOR BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR PLASTER SHALL BE APPLIED TO COVER, BUT NOT SWIMMING POOLS WHERE THE BOTTOM EXPOSED EXTEND BELOW, LATH, PAPER AND SCREED. THE EDGE OF THE GLAZING IS LESS THAN 60 INCHES PROPORTION OF AGGREGATE TO CEMENTITIOUS MEASURED VERTICALLY ABOVE ANY STANDING OR MATERIALS SHALL BE AS SET FORTH IN TABLE WALKING SURFACE, SHALL BE CONSIDERED A R702A(3) HAZARDOUS LOCATION. G.C. TO VERIFY IF HOMEOWNER SELECTS ANY OF THESE ITEMS • WEEP SCREED PER R703.7.2.1 A MINIMUM LISTED. IF ANY OF THESE ITEMS LISTED IS 0.019-INCH (0.5 MM) (NO. 26 GALVANIZED SHEET INSTALLED, SUCH GLAZING FACING THOSE ITEMS GAGE), CORROSION -RESISTANT WEEP SCREED OR IS PLASTIC WEEP SCREED, WITH A MINIMUM TO BE TEMPERED VERTICAL ATTACHMENT FLANGE OF 31/2 INCHES (89 MM) SHALL BE PROVIDED AT OR BELOW THE . PER FBC R312.2, PROVIDE WINDOW FALL FOUNDATION PLATE LINE ON EXTERIOR STUD PROTECTION IN ACCORDANCE WITH R312.2.1 AND WALLS IN ACCORDANCE WITH ASTM C926. THE R312.2.2 WEEP SCREED SHALL BE PLACED NOT LESS THAN 4 INCHES (102 MM) ABOVE THE EARTH OR 2 INCHES (51 MM) ABOVE PAVED AREAS AND SHALL BE OF A • GAS OPT. PER COMMUNITY. VERIFY WITH BLDR TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE • C.J. = RECOMMENDED MASONRY CONTROL JOINT WEATHER -RESISTANT BARRIER SHALL LAP THE LOCATION ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED 0 ALL FINISHES, MATERIALS, HOUSEWRAP, WINDOW AND DOOR FLASHING, TAPING AND SEALANTS TO BE • WATER -RESISTIVE BARRIERS PER R703.7.3, INSTALLED PER BUILDER PROVIDED WATER -RESISTIVE BARRIERS SHALL BE !NSTALLED SPECIFICATIONS OR MFR WRITTEN INSTRUCTIONS AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE • ALL FINISH DETAILS &TYPICAL PLAN NOTES BARRIER WITH A PERFORMANCE AT LEAST PROVIDED BY BUILDER IN ACCORDANCE WITH EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. TYPICAL BUILDER SPECIFICATIONS THE INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER • REFER TO STRUCTURAL ENGINEERING DRAWINGS PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH FOR ALL EXTERIOR WALL STUD SPECIES, SIZES AND SECTION R703.4) INTENDED TO DRAIN TO THE SPACING WATER -RESISTIVE BARRIER IS DIRECTED BETWEEN THE LAYERS ca N ®. APES. � CD CL N N co J W J tds J-6 � trwe, design studios > Z U U 9000 REGENCY SQUARE BLVD.', Q SUITE 100, JACKSONVILLE, FL 32211 0 O CD fl-R-H019ON" �. J <C U Z W 0 W 0 0 0 O) ti o Q Z U) 1U U < — U) 0. W Z �J z w lLl O w W w 0 W ZQ O _ 3 > 0 Q W m w 0 _j w w W O J X LL LL Z Z O O Q 0 IY w Z O a U LL, Q W ABBOTT PARK Q O U J W LL LOT 040-03 0 Q w F_ U Q Z_ Z } 0 C� U) O PROJECT NO w J 2021.006629 0 O LL Z DRAWN: O U KME o CHKD JAC U-)x U) w w Q U Q U) U) 0 m Z 0 Z Q O W U) 2 O Q Z Z 3: cn Q O 05-18-2021 0 � w U REVISIONS: Uj U_ ,-- r Q No. Description Date W U) J 0 - - - U) O h 0 z = 0 U W H X AOOO W d Q I I I I! )ocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 FLOOR PLAN KEY NOTES (SEE SHEET A000 FOR GENERAL NOTES) 11 C9 cV 00 Ln Ln w (D = Lu w= Vn o N u')� 0 m N c� VERIFY AC COND 80 LOCATION WZ SITE PLAN 150115111111 01 9'-4^ 59'-10" 10" 1'-4" 8'-0" 21'-2" 5'-0" J 11'-2" 2'-41/2" 5'-31/2" 10" 2'-4" 11'-8" 2'-8" 3'-6" 3'-4" 25'-2" 25'-2" 2020 FX H8 2020 FX 2020 FX 3052 SH TEMP EGRESS 8'- 0" H.H. 8' - 0" H.H. 8'- 0" H.H. 8'- 0" H.H. 120� ........I I I- - _. - :_..._. ` N 140 3 SHS O O 123 = - I I - "' PANTRY = M w 0D 143 9'-4" CLG "' 00 1 °° " Lu I ! cfl oZSI a = � � � D co00 o — — - (O ' N/ :Ln 1°�s N �, �i N N °° KITCHEN o 9'-4" CLG 101 " N = 130 142 2'-8" 2' 4" BEDROOM 3 "' BATH 2-k: BEDROOM 2 - 00 Ln o o DINING 9'-4" CLG 9'-4" CLG 9'-4" CLG I I N co 9'-4" CLG 0 o 3 SHS _ \ 0 3 SHS v I 101 __ o 0 0 _' �� oo I � N �, N j 1668 1668 Ln u, I V - - - - - -L - - L 21068 108 ' 00 00 0 9'-4" CLG 0 w N OUTDOOR N N N Q 00 LIVING I `" " C9 1 I 9'-4" CLG € I I 102 `r 105 M I I 12' 4" T-5" 4'-3" 2'-2" 13'-6" 7"i T-0" 4'-6" 6-4-5'-0" _ N _ o 10 FOYER N ENTRY �I o q I I ' � o M rn 9 -4 CLG 9'-4" CLGI v v I I 00 6-10" 8 6-4' 8, 9'-2" - I I N Nt { I - - - -- GREAT -- EAT ROOM 1051 ! ! 9'-4" CLG 110�o iv N M 8" 8'-8" 101 N o .......... .. -- I I Q ! I M 4'-10" 162! v 12'-2" 00 8'-2" 9'-4" CLG = O EiqioLAUNDRY 2868 21068 9'-a" CLG _- 00 MECH o 1 0 8 1/2" �9=411 'LG I T-2 " co21'-0" \ N rH� r--� 2106 --------1S&1R------, I,Ln CD O I I O I \ WIC WIC N I I_ Ln 9'-4" CLG GARAGE N N ---� 9'-4" CLG m 160'I WH 2106 BATH 1 BEDROOM 1 9'-4" CLG 1 9'-4" CLG 0 BEDROOM 4 161 M o \> N 9'-4" CLG 21068 21068 i125 00 a i 101 120 N ~ WIC 36"x60" --------- -- 9-4 CLG o ----------- 9'-4" CLG 1S&1R 00 N 3010 FX TEMP 3052 SH TEMP EGRESS + HB 8'- 0" H.H. 8'- 0" H.H. VERIFY AC COND LOCATION I I I W/ SITE PLAN 31'-10" I I 11'-4" 26-10" 17'-8" 5'-8" 5'-10 1 /2" 5'-3 1 /2" 11'4' 2'-8" 21'-6" 70'-0" 1st LEVEL FLOOR PLAN 1/4" = 1'-0" WHEN PRINTED ON 22"x34" 100 - PROVIDE FURRING AS NEEDED 101 - 2x6 WALL 102 - DOUBLE WALL (2-2x4 U.N.O.) 103 - 42" HIGH HALF WALL WITH CAP 104 - DOOR HEIGHT DIFFERS (RE: COMMUNITY/BLDR SPECS) 105 - INTERIOR FLAT HEADER at 8' U.N.O. (SEE PLANS FOR WIDTH) 106 - INTERIOR ARCHED HEADER (from T-4" to 8') (SEE PLANS FOR WIDTH) 107 - SHOWER NICHE 14" x 18" w/BOTTOM at 4'-10" AFF, SHOWER CONTROLS POSITIONED BELOW NICHE 108 - EXTEND 36" H COUNTER 16" OVER 2x6 WALL BELOW 109 - 36" HIGH HANDRAIL 110 - SELF CLOSE DOOR IS 1 3/8" MIN SOLID CORE -OR- 20 MIN FIRE RATED 111 - ATTIC ACCESS - SIZE AS NOTED 20 MIN FIRE RATED 112 - INTERIOR FLAT HEADER at 8-8"' U.N.O. (SEE PLANS FOR WIDTH) 120 - RECESSED TILE SHOWER - SIZE AS NOTED 121 - TILE SHOWER WITH CURB - SIZE AS NOTED 122 - VIKRELL BASE SHOWER - SIZE AS NOTED 123 - TUB R.O. 5'-0 ''Y4" 124 - GARDEN TUB - SIZE AS NOTED 125 - TEMPERED GLASS SHOWER ENCLOSURE 126 - TEMPERED GLASS SHOWER ENCLOSURE ON 42" H 1/2 WALL w/SLP TOP 127 - SHOWER SEAT AT 18"x18"x20" 128 - SHOWER BENCH 129 - LAUNDRY SINK 130 - SINK 140 - OVERHEAD CABINET 141 - REFRIGERATOR - OPTIONAL 142 - DISHWASHER 143 - RANGE WITH MICRO HOOD 144 - COOKTOP 145 - DOUBLE OVEN 146 - WASHER - OPTIONAL 147 - DRYER - OPTIONAL 160 - INSTALL MECH PROTECTION PER CODE 161 - EQUIPMENT STAND LOC at 18" AFF FOR GAS WH ONLY 162 - LOUVERED DOOR 163 - METAL A/C STAND 164 - BOLLARD AS REQ. PER BUILDING CODE 180 - EXTERIOR HEADER (RE: ELEVATION) 181 - SYNTHETIC STONE VENEER O O N N O O rn N N c'7 J LL w J J z O U) Y U ¢ 0 O r w H J m w 0 W z w 0 w w O O O rn z co w z cn Z) m w w z CD w 0 J IL z O t- (I Ef U O J IL ¢ z } O J O w W w X W 0 O ¢ z U) Z) _O H H LL 0 O J O z U w X w a APEX tds true resign studios 9000 REGENCY SQUARE BLVD. SUITE 100, JACKSONVILLE, FL 32211 tm Q u) � a w � o LLJ LLJ n p Q � o im / 0 L1J ¢ 0 W ui 0 L1J W 2 x x a �� z O 0 z w ABBOTT PARK Q 0 LOT 040-03 0 Q z 0 PROJECT NO w 2021.006629 0 LL - -- O DRAWN: o KME o CHKDL0 JAC U) w J z U) z_ ¢ 05-18-2021 p w REVISIONS: No. Description Date ~ w � J - - U) � I F-- ' O iz O 0 A110 )ocuSign Envelope ID: 804C66C7-1A16-4461-A7C7-0002ED72E266 12 5 1st LEVEL BRG 1st LEVEL BRG l�J - • F 1s LEVEL FFE t 1st LEVEL FE 0 0" - 0 LEFT ELEVATION 1/8" = V-0" WHEN PRINTED ON 22"x34" ROOF VENTILATION VENT VENT i PROP PROP Area HIGH LOW # RATIO HIGH LINEAL FT LOW [2738 SF 657 in _F657 in 4 144 576 160 1470.4 E. ROOF PLAN 1/8" = 1'-0" WHEN PRINTED ON 22"x34" 12 5 1st LEVEL BRG S I I n i� 1st LEVEL FFE 1st LEVEL FFE RIGHT ELEVATION 1/8" = V-0" WHEN PRINTED ON 22"x34" 12 5 _/ REAR ELEVATION 1/8" = V-0" WHEN PRINTED ON 22"x34" 1st-LEVELBRG 1st LEVEL FFE 01-01, {220 ELEVATION KEY NOTES (SEE SHEET A000 FOR GENERAL NOTES) 200 - CONCRETE TILE ROOF 201 - SHINGLE ROOF 202 - TAMKO OFF RIDGE VENT 203 - LOMANCO ROOF VENT 204- MILLENNIUM ROOFVENT 220 - FOUNDATION WALL FINISH LINE WISTUCCO PARGE COAT 221 - CEMENT PLASTER FINISH - OVER CONCRETE MASONRY SHALL BE 112" THICK TEXTURED PER COMMUNITY SPECIFICATIONS SEE GENERAL NOTES A000 FOR SPECIFICATIONS 222 - CEMENT PLASTER FINISH - OVER WOOD FRAMED WALLS SHALL BE 7/9' (3 COAT) TEXTURED PER COMMUNITY SPECIFICATIONS. OVER ASPHALT IMPREGNATED PAPER BACK WIRE LATH AVER HOUSE WRAP OVER EXTERIOR SHEATHING PER STRUCTURAL DRAWINGS- LATH TO BE FURRED OUT FROM BACKING FROM AN APPROVE METHOD IN ACCORDANC E WITH FBC R703-7 SEE GENERAL NOTES A000 FOR SPECIFICATIONS 223 - FIBER CEMENT LAP SIDING 224 - FIBER CEMENT SHAKE SIDING 225 - FIBER CEMENT BOARD & BATTEN SIDING 226 - SYNTHETIC STONE VENEER 227 - STONE LEDGE 228 - BRICK VENEER 229 - FOAM CAP 240 - EXTERIOR DOOR SIZE PER FLOOR PLAN 259 - 2"k TRIM - SIZE AS NOTED 260 - CV BAND - SIZE AS NOTED -1 " PROJ U.N.O. 261 - CV BAND - SIZE AS NOTED - 2" PROJ U.N.O. 262 - 1'k TRIM -SIZE AS NOTED 263 - DECORATIVE SHUTTER - SIZE AS NOTED 264 - DECORATIVE BRACKET - AS NOTED - OR EQUIVALENT 265 - DECORATIVE LOUVER - SIZE AS NOTED 266 - V DECORATIVE DRAT N TI LES 267 - 42" HIGH RAILING IS POWDER COATEDALUMINUM, AND COLOR IS DETERMINED BY THE BUILDER'S SPECS 280 - EXTERIOR WALL MOUNTED LIGHT FIXTURE. € OF LIGHT TO BE 6 -4T A_ F.F. U.N.O. O. ea O O O T APEX d lit � n N c J � Ld %�o LL J J N true design studios, 3.1 O U) U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 0 o � O wa F_ (A 'H019ON N Q J�_.. z z w if Q C) U Z w CD w O O O c) ti L0 >= O Q w Z w U Q _ U) � W J z w m LLJ O w w w Q w z cD > Q Q W m w o o ® Jw� w w ti O �' �/ J x LL LL �— Z O z O Q 0 a_ z w w O 0- U w pw ABBOTT PARK Q O U U- LOT 040-03 0 Q w U Q z_ z O PROJECT NO w 1 2021.006629 O LL- z O DRAWN U KME o P_ LO CHKD JAC W X w w � U Q U) } C� m z_ 0 w Q Z 0 O w U) C7 Q z z U Q O 05-18-2021 p w U REVISIONS: LL - r Q No. t Description j Date -- w U) J O H OZ Z = O U 0 w F_ x w A200 a_ Q DocuSign Envelope ID. 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 INSULATION BAFFLE BETWEEN TRUSSES INSTALLED PER MFR WRITTEN SPECS CONCRETE TILE ROOFING INSTALLED PER MFR SPECS OVER VARIES (RE: \ WD SHTHG OVER PRE-ENG WD 'k_�_9OF PLAN) TRUSSES (RE: STRUCTURAL) ALUMINUM DRIP OVER 1x2 DRIP EDGE OVER 2x6 FASCIA W/ ALUMINUM WRAP VENTED SOFFIT INSTALLED PER MFR WRITTEN SPECIFICATIONS NOTE- INSTALL PORTLAND CEMENT BASE PLASTER IN ACCORDANCE WITH ASTM 926 AND ASTM C 1063 NOTE: INSTALL ALL VINYL CV ACCESSORIES PER MFR WRITTEN SPECIFICATIONS INSULATION BAFFLE BETWEEN TRUSSES INSTALLED PER MFR WRITTEN SPECS FIBERGLASS SHINGLE ROOFING 12 VARIES (RE: ELEVATION) F_ INSULATION PER CODE 1i2" MINIMUM SAG RESISTANT CEILING GYP BRD PER FBCR TABLE R702.3.5 POURED BOND BEAM (RE- STRUCTURAL) PRE CAST LINTEL (RE: STRUCTURAL) NOTE: RE: FLOOR PLAN (SH Al 10/A120) FOR WINDOW SIZE. RE: WINDOW MFR SPECS FOR CODE COMPLIANCE AND INSTALLATION DATA TYP ONE-STORY WALL SECTION INSTALLED PER MFR SPECS OVER VARIES (RE: \ WD SHTHG OVER PRE-ENG WD ROOF PLAN) TRUSSES (RE: STRUCTURAL) I ALUMINUM DRIP OVER lx2 DRIP EDGE OVER 2x6 FASCIA W/ ALUMINUM WRAP ���04 .. VENTED SOFFIT INSTALLED PER MFR WRITTEN SPECIFICATIONS NOTE: INSTALL PORTLAND CEMENT BASE PLASTER IN ACCORDANCE WITH ASTM 926 AND ASTM C 1063 NOTE: INSTALL ALL VIN ACCESSORIES PER MF WRITTEN SPECIFICATI( §8" THICK STUCCO FIND TEXTURED PER COMMI SPECIFICATIONS STUCCO PARGE COAT GRADE (SLP AWAY FRC STRUCTURE)(TYP ALL SCALE: 1" = 1'-0" VARIES (RE: 12 ELEVATION) 1st LEVEL TOB VARIES (RE: ELEV) INSULATION PER CODE 12" MINIMUM SAG RESISTANT CEILING GYP BRD PER FBCR TABLE R702.3.5 POURED BOND BEAM (RE: STRUCTURAL) PRE CAST LINTEL (RE- STRUCTURAL) NOTE: RE: FLOOR PLAN (SH All 0/A120) FOR WINDOW SIZE. RE: WINDOW MFR SPECS FOR CODE COMPLIANCE AND INSTALLATION DATA 1 /2" GYP BRD OVER ALUMINUM FOIL INSULATION W/ 1x2 TREATED FURRING STRIPS at 24" O.C. MAX 1x TREATED FURRING TYP at TOP & BOT OF BLOCK WALL MAIN FIN FLR 0'-0" ° pi�TALL VAPOR BARRIER IN ACCORDANCE WITH ASTM E 1643-98 - FOUNDATION/FOOTING VARIES a (RE: STRUCTURAL) aOO YP ONE-STORY WALL SECTION SCALE: 1" = V-0" C O O O U N IT IT APEX U O rn x r � CU N N M J LL 1 W J z tdb O true dews €i studios L7 Y U 9000 REGENCY SQUARE BLVD. o SUITE 100, JACKSONVILLE, FL 32211 C) r 0 LLJ U) rs > m®BIsH 0 90 N J Q9 W A a.° spi, goa�Of C� U U w w Ir O O O v LO ti O z U) w w z_ W cn � mL.1.. — N w w w z (f) z G w Q O o 0 O J W WLL O w a w O XU - Q r r 0 z w O O LLww Q z z U z ILL 0 W O -- Q J U O U) z PROJECT NO o U w W W Q ~ z IX DRAWN: a DVO Q CHKD: W TSD 0 U_ O m o LO w m z - ?>> w O J Q W U Q rn z (D U) z D 3: O � o LL U) Q O U) z REVISIONS: Q ry 0 No. Description Date o O W z U)= w U = W ~ H LLI LU -- - Q Q H A400 z O 0 DocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 WOOD SHEATHING WRB LAYER #1, STUCCO WRAP METAL LATH 7/8" THICK, 3 COAT CEMENT PLASTER LAP WRB & TAPE OVER ROOF/WALL SCREED 5"x5" "L" TYPE CONTINUOUS GALV. METAL FLASHING (NAIL TO ROOF DECK, NOT WALL SHEATHING) CAP SHINGLE - DO NOT NAIL, INSTALL WITH ROOF CEMENT ROOF CEMENT "L" FLASHING SHINGLE ROOFING SCALE: N.T.S. • O 1. FOLD INWARD at PT. A O 1. FOLD INWARD at PT. A 2. CREASE at PT. B ® FOLD FOLD at 45° ®1. FOLD INWARD at PT. A 2. CREASE at PT. B 3. CREASE at PT. C 4. FOLD PT. C OVER PT. B UNTIL PT. C TOUCHES BOTTOM FLANGE FELT U SHINGLE ROOFING DRIP EDGE: OVERLAP T, EXTEND 1/2" BELOW SHEATHING, MECHANICALLY FASTEN 4" O.C. MAX BOTTOM O1. FOLD INWARD at PT. A 2. CREASE at PT. B 3. CREASE at PT. C ® ©FOLD at 77° WATER TIGHT SEAL. FOLD, DO NOT CUT 7/8" THICK, 3 COAT CEMENT PLASTER WRB LAYER #2, FORTIFIBER BUILDING PAPER WRB LAYER #1, STUCCO WRAP LAP LAYERS OF BUILDING WRAP OVER NAILING FLANGE, STOP WRB APPROX. 1 1/2" ABOVE SHINGLES x ROOF/WALL SCREED x x x x x 5x5 WALL FLASHING x x °O Mi�iy _ Z CLN w� CZ Zw >- n. x x x x x FLASHING (SEE DETAIL) WATER TIGHT SEAL (BEND OR SOLDER, FASCIA WRAP NOTE: INSTALL KICKOUT FLASHING AT BOTTOM OF ROOF & WALL INTERSECTIONS WALL KICKOUT FLASHING SCALE: N.T.S. BLDG PAPER OVER 'QUICK FLASH" PIPE THROUGH WAL 6" SELF ADHESIVE FLASHING (INSTALL PER MANUF. SPECS' BLDG PAPER UNDER 'QUICK FLASH" VENT PENETRATION O L� SCALE: N.T.S. CUT OPENING IN APPROVED HOUSEWI FOR BOX INSTALLATN WRB LAYER #1, STUC WRAP WOOD SHEATHING APPROVED HOUSEWF BELOW CUT SUCH THAT NO MEMBRANE ENTERS BOX, APPLY TO FACE EDGE APPLY E-Z BEAD OVER 60 MIN GRADE 'D' FELT -PROVIDE SEALANT AT ALL JOINTS AND INTERSECTIONS STEP #1 CTCC] Jl'] STEP #5 WRB LAYER #1, STUCCO WRAP CUT "X" INTO SELF - ADHERING MEMBRANE FLASHING APPLY SELF -ADHERING MEMBRANE FLASHING OVER BOX AND OVER APPROVED WRB LAYER #1 ELECTRICAL RECEPTACLE _T/ - + 7 2x SUB-BAND\W/1/2"X? NOTCH @ END, WRAPPED IN PEEL & •� STICK \ DRIP EDGE II 1/8" �8" TEXTURED \ \\ FINISH @ WOODII , TEXTURED 1 1/8" Fv • �il FINISH @ CMU / \ WRAP \ 1"FROM \ METAL FASCIA STUCCOI, ✓ FROM WObD WALL <i j \ EXTERIOR WALL \ \ / OR CMU) _�FR'AME \ NOTE: NOTCH FOR 2x6 SUB \ ROOF KICK OUT BAND ONLY REMOVED FOR CLARITY \ ROOF DECK (BEYOND) ELEVATION PRE-ENG'D TRUSS TO BE CUT @ WALL INLET TO AVOID CONTACT W/ TEXTURED FINISH 2"x4"x4'-0" SCABBED TO TRUSS W/12d DRIP EDGE, 1" OFF WALL '(NOT INTO STUCCO) 3-COAT PLASTER �- 2x6 SUB -BAND W/1"x4" NOTCH @ END, WRAPPED IN PEEL & STICK �- METAL FASCIA WRAP 1" OFF WOOD WALL. SUB -BAND 2" OFF WOOD WALL NAILS 6 -8 O.C. MAX METAL FASCIA WRAP 2x SUB -BAND W/1 12"x4" NOTCH @ END METAL WRAP FASCIA DRIP EDGE EXTERIOR WALL (FRAME OR CMU) © PLAN B WRB LAYER #1, STUCCO WRAP APPLY 60 MIN GRADE 'D' FELT OVER SELF - ADHERING FLASHING OVER APPROVED HOUSEWRAP WRB LAYER #2, FORTIFIBER BLDG PAPER 8" STEP #2 STEP #4 STEP #6 SELF - ADHERING MEMBRANE FLASHING ELASTOMERIC COATING OVER STUCCO/ C.V. FINISH (SEE TYP WALL SECTION) METAL LATH SCALE: N.T.S. FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS METAL FLASHING, WRAPPED MIN 1" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/1/2"X? NOTH @ END, WRAPPED IN PEEL & STICK -ROOF CEMENT @ ROOF EDGE OMITTED FOR SUB BAND DETAIL (a. WALL CLARITY IVIL 1 (lL L/1 I 1 I WOOD SHEATHING WRB LAYER#1, STUCCO WRAP WRB LAYER #2, FORTIFIBER BUILDING PAPER ROOFING CEMENT DRIP EDGE METAL KICK OUT WALL KICK -OUT FLASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS METAL FLASHING, WRAPPED MIN 4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/1/2"x? NOTH @ END, WRAPPED IN PEEL & STICK °7 *ROOF CEMENT @ ROOF EDGE OMITTED FOR CLARITY SUB BAND DETAIL WALL W/ KICK -OUT SUB BAND DETAIL @ WALL SCALE: N.T.S. E O O O L.7 00 N '�t EX I -CI C:)�'. :: O a), X. N C( N M J LLZz w J J Z tds O true design studios Y U 9000 REGENCY SQUARE BLVD. j o SUITE 100, JACKSONVILLE, FL 32211 c O cn T_ _© w Z3 I-- � o a J,�1/� 0-fl-HOMON' W LLJ "ke s$ W' tQ Q`'' 0 U Z W w O O O O t` d' LO I` O Z U) (n W V, I� Zui W � m ..w W W Z Z 75 w Q O w O U- w W o Q Q o Q� O a w O U X Q 0 0� T_ Z O 0U- 0 LLI ~ Q Z U Z 0- } IL (D W O -- Q J U O U) Z PROJECT NO w U W Q ~ -- - Z w DRAWN: DVO Q CHKD: Q TSD LL O } m � 0 O LO W U) Z — W O J w U 2 W Z 0 U) Z D _O Q I-- U_ LL. U) Q (n Z REVISIONS: - -- 0 No. Description Date I:) O w Z -- (n r w U - 2 w ~ I-- - - - w J W - - D_ U Q F- A500 Z 0 0 )ocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 1/2" (MIN) STL FINISH TEXTL PER COMMUt SPECIFCATIC FLANGE CASI BEAD CASING BEAD at WN SCALE- N.T.S. e. �I 5/8" CEMENT PLASTER ` 12" WIDE SELF-ADHESIVE FLASHING CENTERED UNDER CONTROL JOINT (CLEAN MASONRY BEFORE APPLYING) PRE -FORMED CONTROL ;. JOINT W/ STRIP LATH t. CONTROL JOINT - HORIZ - CMU SCALE: N.T.S. VINYL ANGLED CASING BEAD (AM66-ANGLED-1250) 0 z O =w (' J W i� VINYL CASING BEAD (AM66-1250) 1/2" (MIN) TEXTURED FINISH at MASONRY RAISED BAND at BLOCK SCALE- N.T.S. 1z" GYP BIRD OVER — PRE -SHAPED STUCCO BAND 1x2 TREATED W/ SLIP TOP INSTALLED PER FURRING STRIPS MFR WRITTEN SPECS (RE: at CMU WALL (TYP) ELEV) SELF ADHESIVE -OR- FLUID APPLIED FLASHING (CLEAN MASONRY BEFORE APPLYING) PT 1x WOOD BUCK VINYL FLANGE CASING BEAD SHIM AS NEEDED INSTALLED PER MFR WRITTEN SPECS (TYP) 4e" BACKER ROD W/ SEALANT INTERIOR EXTERIOR WINDOW HEAD at CMU SCALE: 1 1/2" = 1'-0" PRE -FORMED CONTROL / \ JOINT W/ STRIP LATH 5/8" CEMENT PLASTER 12" WIDE SELF-ADHESIVE FLASHING CENTERED UNDER CONTROL JOINT (CLEAN MASONRY BEFORE APPLYING) CONTROL JOINT - VERTICAL - CMU 2 1/2" SCALE: N.T.S. CORNER BEAD (FASTENER & SPACING at 7" O.C.) ;MU 1/2" (MIN) STUCCO FINISH TEXTURED PER COMMUNITY 3PECIFCATIONS CORNER BEAD at BLOCK SCALE: N.T.S. CMU WALL W/ 4a' STUCCO FINISH (RE: STRUCTURAL) GYP BIRD OVER PRE -SHAPED STUCCO BAND 1x2 TREATED W/ INSTALLED PER MFR FURRING STRIPS WRITTEN SPECS (RE: ELEV) at CMU WALL (TYP) WOOD BLOCKIN SELF ADHESIVE -OR- FLUID APPLIED FLASHING (CLEAN MASONRY BEFORE APPLYING) PT 1x WOOD BUCK VINYL FLANGE CASING BEAD SHIM AS NEEDED INSTALLED PER MFR WRITTEN SPECS (TYP) �8' BACKER ROD W/ SEALANT INTERIOR EXTERIOR WINDOW JAMB at CMU SCALE: 1 1/2" = 1'4' STUCCO FINISH 6" SELF ADHESIVE OVER TOP & SIDES SELF FLASHING UNIT PREMANUF. DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT at TOP & SIDES DRYER VENT (BLOCK) SCALE: N.T.S. 6" SELF -ADHERING FLASHING WEATHER RESISTIVE BARRIER #1 WEATHER RESISTIVE BARRIER #2 6" SELF -ADHERING FLASHING GALV'D MI 7" FLASI DO NOT CA—, SEAL OPENING 1 1/4" X 6" SIMULATED WOOD TRIM MEMBER SEAL GAP W/ CAULKING — OR APPROVED SEALANT STUCCO CASING BEAD SIDING TO STUCCO FRAME TO BLOCK SELF ADHESIVE -OR- FLUID APPLIED PAN FLASHING (CLEAN MASONRY BEFORE APPLYING) EXTEND UP AT JAMBS (4" MIN) PRECAST CONCRETE SILL I : BACKER ROD W/ SEALANT VINYL FLANGE CASING BEAD GYP BIRD OVER INSTALLED PER MFR 1x2 TREATED WRITTEN SPECS (TYP) FURRING STRIPS CMU STEMWALL W/ at CMU WALL (TYP) 48" STUCCO FINISH (RE: STRUCTURAL) INTERIOR EXTERIOR WINDOW SILL at CMU SCALE- 1 1/2" = 1'-0" ELECTRIC ME1 FIELD VERIFY LOCATION AREA TO RECE. STUCCO SCRATCH COAT & 1 COAT OF PAINT W/ BACK -ROLL PRIOR TO ELECTRIC METER INSTALLATION ELECTRICAL CONDUIT PENETRATION WOOD CONST BEYOND WOOD SHEATHING WEATHER RESISTIVE BARRIER #1 WEATHER RESISTIVE BARRIER #2 5/16" X 7 1/4" LAP SIDING W/ 6 REVEAL STARTER STRIP DO NOT CAULK OR SEAL OPENING GALV'D METAL "Z" FLASHING 1 1/4" X 6" SIMULATED WOOD TRIM MEMBER STUCCO CASING BEAD SCALE: N.T.S. GYP BIRD OVER 1x2 TREATED FURRING STRIPS at CMU WALL (TYP) PT 1 x4 PT 2x4 FRAME ANCHOR SHIM AS NEEDED INTERIOR WD SHE (RE:STR DNE (1) ELECTRIC CAVITY TO BE FILLED WITH RIGID POLYMERIC ISOCYANOTE-POLYBLEN FOAM ("GREAT STUFF" OR SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEC WIRE PENETRATES PROVIDE STUCCO SCRATCH COAT LARGER THAN THE ELECTRIC METER CAN OR METER CAN COMBO OR METER CAN AND DISCONNECT SCALE: N.T.S. FIBERCEMENT -OR- VINYL LAP SIDING OVER APPROVED HOUSEWRAP INSTALLED PER INISH COATING OVER PRIMED MFR WRITTEN SPECIFICATIONS HREE COAT STUCCO FINISH EXTEND HOUSEWRAP a" NOM) OVER GALV MTL LATH OVER NAILING FLANGE VIER 15# FELT OVER APPROVED DUSEWRAP WD SHEATHING (RE: STRUCT) Y _— ASTEN TO WD STRUCTURAL �f (EMBER at 7" O.C. MAX MTL DRIP FLASHING W/ HEMMED EDGE SET IN CONT " TO §a" MID WALL BEAD OF SEALANT JEEP SCREED -�_ TRIM (RE: ELEVATION) Z a- N EXTEND 12" SELF -ADHERING _j - MEMBRANE FLASHING OVER WINDOW FLANGE ET IN CONT " WIDE STRIP SELF ADHESIVE 1 BEAD OF SEALANT 'LASHING, CLEAN MASONRY - 9EFORE APPLYING - -- -- I;' VINYL FLANGE CASING BEAD INSTALLED PER MFR /2" (MIN) STUCCO FINISH WRITTEN SPECS (TYP) 'EXTURED PER COMMUNITY ;PECIFCATIONS 1/2" (MIN) STUCCO FINISH 1 TEXTURED PER COMMUNITY SPECIFCATIONS STUCCO SIDING HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOC v CMU LINTEL (RE: STRUCTURAL) DOOR HEAD at CMU CONTINUOUS BEAD OF SEALANT SELF ADHESIVE -OR- FLUID APPLIED FLASHING (CLEAN gMpApS�OYNNRGY�BEFORE METAL( DOOR FRAME EXTERIOR SCALE.- 1 1/2" = 1'-0" GYP BIRD OVER 1x2 TREATED FURRING STRIPS at CMU WALL (TYP) PT 1 x4 PT 2x4 FRAME ANCHOR SHIM AS NEEDED INTERIOR DOOR JAMB at CMU SCALE: N.T.S. CMU WALL W/ 1/2" (MIN) STUCCO FINISH (RE: STRUCTURAL) CONTINUOUS BEAD OF SEALANT SELF ADHESIVE -OR FLUID APPLIED FLASHING (CLEAN gM�APSLOYNNRGY�BEFORE METAL( DOOR FRAME EXTERIOR SCALE.- 1 1/2" = 1'-0" O O O U N O co (APEX U O � X N C� N co J LLzz J Z tds a) O true design studios CD U 9000 REGENCY SQUARE BLVD. o SUITE 100, JACKSONVILLE, FL 32211 c O vi 0 w co o a) -Ha a) Uj Q �\•,� U Z W >N W > O O O d� ti LO ti O Z c co Z U :D m I..L W W Z �W U) Z G w Q O Q o J W W O LL_ Q L1" o o- af O X Q Z O O LL H Q Z U 0Y Z 0- LL } — W J O -- Q J U O � Z 0 PROJECT NO. W U I— W Q I-_- _ rn w DRAWN Z V DVO Q CHKD w Q TSD O m O w U) Z w O -t Q w U 2 C/) Q (n Z (D U) Z O Q Cn LL Q z W Z REVISIONS: No. Description_ Date o O W Z U) _ W U = W H w -- _ W X J W - —� U 0- Q � A501 z O 0 )ocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 I -ll - -- - - -' L L 1 I 1 1 I I I 1 1 PANEL 1 RATING: 200A MLO MIN AIC RATING: 22,000 A PANEL • SERVICE: 120/240V, 10-3W MOUNTING: SURFACE CiESGRIPTI> AI WATER HEATER LOAD TYPE F POLES 2 BRK 30 CIRCt IV!v}, 1 PHASE A CIRCUIT NO. 2 BRK 20 POLES 1 LOAD R DESCRIPTION APPLIANCE GFI 3 B 4 20 1 R APPLIANCE GFI SYS, 1 CONDENSING UNIT M 2 30 5 A 6 20 1 L,R GREAT ROOM 7 B 8 20 1 1 L,R DINING SYS. 1 AHU M 2 20 9 A 10 20 1 L.R BED 2 11 B 12 20 1 L,R BED 3 DRYER F 2 30 13 A 14 20 1 L,R BED 4 15 B 16 20 1 L,R OWNERS OVEN/RANGE F 2 40 17 A 18 20 1 L,R GARAGE/EXTERIOR 19 B 20 20 1 - SPARE REFRIGERATOR F 1 1 20 21 A 22 20 1 1 - SPARE GARAGE DOOR OPENER F 1 20 23 B 24 20 1 - SPARE DISHWASHER/DISPOSAL F 1 20 25 A 26 20 1 - SPARE MICROWAVE/HOOD F 1 20 27 B 28 20 1 - SPARE LAUNDRY R 1 20 29 A 30 20 1 - SPARE AFI / ..... GFI GF.L.... AFI :.. AFI PH 1st LEVEL ELECTRICAL PLAN 1/4" = V-0" WHEN PRINTED ON 22"x34" ELECTRICAL LOAD CALCULATIONS LOAD DESCRIPTION CONNECTED LOAD (VA) DEMAND FACTOR FINAL LOAD (VA)' GENERAL LIGHTING {3 VAlFT2) 6102 - - SMALL APPLIANCE 1500 - - SMALL APPLIANCE 1500 - - LAUNDRY CIRCUIT 1500 - - DISHWASHER 1500 - - WASTE DISPOSAL 800 - - WATER HEATER 4500 - - OVEN/RANGE 14900 - - MICROWAVE/HOOD 1000 - - GARAGE DOOR OPENER 600 DRYER 5400 - - GENERAL LOAD 10000 100% 10000 GENERAL LOAD 29302 40% 11720.8 HEATING/AC (2.5 TONS + 3 kW) 6438 100% 6438 TOTALS 45740 - 28159 120/24OVSERVIC E/F EE DER LOAD (A) 117 MAIN BREAKER (A) 200 ----- — — ...... _ _. .................. ........ a ......._... /, /----- x a \`. VP , F-AlII GFI CLG GFI IRR ELEC PANEL WP GFI VERIFY AC COND LOCATION W/ SITE PLAN Q ELECTRICAL LEGEND SINGLE POLE SWITCH DOOR BELL BUTTON 3-WAY SWITCH CHIME DOOR BELL CHIME t4-WAY SWITCH GARAGE DOOR - BUTTON - - DIMMER SWITCH T--T GARAGE DOOR OPENER F 220 VOLT OUTLET GFCI DUPLEX OUTLET I DUPLEX OUTLET CEILING OUTLET CLG AFIAFCI DUPLEX OUTLET R FLOOR OUTLET ® SMOKE DETECTOR B JUNCTION BOX © CARBON MONOXIDE ® CARBON MONOXIDE & DETECTOR SMOKE DETECTOR TELEVISION OUTLET A NETWORK OUTLET PANEL SERVICE PANEL A TELEPHONE OUTLET SERVICE METER m GARBAGE DISPOSAL WALL MOUNT LIGHT SINGLE SCONCE FLOOD LIGHT DOUBLE SCONCE STRIP LIGHT ® STAIR LIGHT BATH FAN & LIGHT COMBO - VENT TO EXT BATH FAN - VENT TO EXT CLOSET CASTER ® CASTER LIGHT UNDER CABINET LIGHT PULL CHAIN LIGHT 4- KEYLESS LIGHT -0- FLUSH MOUNT LIGHT _(%NGING1 HANGING LIGHT HANGING PENDANT ¢ MINIATURE PUCK PNDT LIGHT MINI LIGHT LED FLUSH MOUNT RECESSED EYEBALL DISC LIGHT LIGHT FLUORESCENT LIGHT ®FIR FLUORESCENT LIGHT RECTANGULAR ROUND PRE -WIRE FOR CEILING FAN( CLG FAN ROUGH -IN C, J LIGHTED ;? PRE -WIRE FOR CLG FAN w/ CEILING FAN\ LIGHT ROUGH -IN 0' ca. o a o p 04 LO APEX c* CD , tT3 N M _I LL � W tds J true design studios a) z O U) U 9000 REGENCY SQUARE BLVD.', Q SUITE 100, JACKSONVILLE, FL 32211 -� _0 o C) « « a) 0 > A "I ..° 0 Q,+ ' F coa f �' , ww W Q 4 a :' 0 CO U z W w 0f 0 0 0 >= ti d' ti O a Lo z w (n Q _ (1)0. W —� z w m LU 0 cr) w w Qw Q z 3 > � a W m w 0 o � J w O w w � x LL LL z a z O z O w a- z O a U__ Q w ABBOTT PARK Q o U) Q LOT 040-03 0 I- U Q z_ z ,>_ U v PROJECT NO: w O p 1 2021.006629 w z O DRAWN: U KME o CHKD: J B B U) w w U X Lo m z 0 3: w z Q o� w U) 2 O Q z z C� Q 0 05-18-2021 p W U_ REVISIONS: LL � Q No. Description Date w U) - Q -- U) O I- z z = O U 0 w I— X El 00 w w Q )ocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 DESIGN CRITERIA AND LOADS Building Code Florida Building and Residential Codes , 7th Edition (2020) Code for Desiqn Loads ANSI/ASCE 7-16 ROOF LOADING'..... .......................................... Cd = 1.25 TOP CHORD LIVE LOAD .................................. 20 PSF TOP CHORD DEAD LOAD................................7 PSF (TILE = 15 PSF) BOTTOM CHORD LIVE LOAD ATTICS WITH LIMITED STORAGE ............... 20 PSF ATTICS WITHOUT STORAGE .......................10 PSF (NON -CONCURRENT) BOTTOM CHORD DEAD LOAD........................5 PSF WIND LOADING ................................................. Cd 1.60 ASCE 7-16, 3S GUST........................................139 MPH BASIC WIND SPEED EXPOSURE CATEGORY..................................0 BUILDING CATEGORY.....................................II ENCLOSURE CLASSIFICATION- . - ENCLOSED INTERNAL PRESSURE COEFF.......................0 18 C&C DESIGN PRESSURES..............................(SEE TABLE 1) FLOOR LOADING ........... .......... ........... ..............Cd = 1.00 TOP CHORD LIVE LOAD..................................40 PSF TOP CHORD DEAD LOAD................................10 PSF BOTTOM CHORD LIVE LOAD..........................0 PSF BOTTOM CHORD DEAD LOAD........................5 PSF SPECIAL FLOOR (GAME ROOM) LOADING. ...Cd = 1.00 TOP CHORD LIVE LOAD..................................60 PSF TOP CHORD DEAD LOAD................................10 PSF BOTTOM CHORD LIVE LOAD ...........................0 PSF BOTTOM CHORD DEAD LOAD........................5 PSF MAXIMUM FLOOR TRUSS SPACING...............16" O.C. DEFLECTION CRITERIA LL / 240 ROOF TRUSSES .............................................. TL / 180 TL MAX 1" UP TO 40' SPAN LL / 480 TL / 360 OPEN WEB FLOOR TRUSSES ....................... LL / 480 TL / 240 WOOD I JOISTS ............................................... TL MAX 1/2" LL / 360 BEAMS'.............................................................TL/240 NOTES: 1. PORCH BEAMS AND BEAMS SUPPORTING EXTERIOR WALL ABOVE SHALL NOT EXCEED %" DEFLECTION TABLE 1: COMPONENT AND CLADDING DESIGN PRESSURES WINDOWS AND DOORS EFFECTIVE WIND AREA ZONE DESIGNATION IZ - Interior Zone (psf) EZ - End Zone (psf) 0-20 ft2 +28.54 -30.96 +28.54 -38.22 21 - 50 ft2 +27.17 -29.59 +27.17 -35.47 51 - 100 ft2 +25.52 -27.94 +25.52 -32.17 101 - 200 ft2 +24.25 -26.67 1 +24.25 -29.64 SOFFIT MAX PRESSURE (psf) +28.6 -38.3 GARAGE DOOR PRESSURE +21.7 -24.6 END ZONE KEY MAP END ZONE: END ZONES SHALL BE TAKEN AS THE 1ST 4.0' PER FIGURE R301.2 (7) 'III I 4.0 F7 1 ST FLOOR (TYP) END ZONE DESIGNATION TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS NOTFS 3 4 p (D STUCCO AND DIRECTLY MIN 1%2" 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICALLY OR (%6" 24/16 ADHERED STONE INSTALLED HORIZONTALLY) W/ 8d COMMON: 6" O.C. AT PANEL EDGES, 12" O.C. IN THE ^ Lu Q N (NOTE 6) FIELD. 2x4 BLOCKING IS RECOMMENDED AT UNSUPPORTED PANEL EDGES. ww� J v J ? ALL OTHER VENEER MIN 1%/ '32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICAL OR HORIZONTAL (NOTE 8) W/ 8d COMMON: 6" O.C. EDGES AND FIELD (UNBLOCKED HORIZONTAL PANEL EDGES); 6" O.C. AT PANEL EDGES, 6" O.C. IN FIELD (BLOCKED HORIZONTAL PANEL EDGES) Y C� rn TILE AND METAL ROOF MIN 1V32" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION .6 (NOTE 7) PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 4" O.C. AT PANEL EDGES AND o 6" O.C. IN THE FIELD LL 0 w � MIN %s' 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED WITH LONG DIMENSION O 0 SHINGLE ROOF PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 6" O.C. AT PANEL EDGES, 6" O.C. IN THE FIELD. FLOOR DECK SHEATHING: 23/32" T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O.C. IN THE (NOTE 5) FIELD. MIN %" OSB OR PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d PORCH CEILING BOARD SHEATHING: COMMON: 3" O.C. AT PANEL EDGES 12" O.C. IN THE FIELD OR MIN Y2" EXTERIOR GYPSUM CEILING BOARD, FASTEN w/ 5d x 1 /" COOLER NAIL OR NO.6 x 1 %" LONG SCREWS @ 4" O.C. EDGES, 8" O.C. FIELD NOTES: 1. FOR SHEATHING THICKNESS GREATER THAN 1%2" CATEGORY, USE RSRS-03 NAILS. 2. COMMON NAILS IN WALL SHEATHING MAY BE SUBSTITUTED W/ 8d GALVANIZED BOX NAILS. 3. ZIP WALL SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED WOOD STRUCTURAL PANEL. 4. ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF CURRENT APPROVEDAPA.MANF. SPECIFICATIONS. 5. FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TO REDUCE SQUEAKING, RSRS-01 NAILS OR 8d SCREW NAILS ARE RECOMMENDED. 6. 15/32" 32/16 SPAN RATED OSB OR PLYWOOD WITH BLOCKED PANEL EDGES IS AN APA RECOMMENDATION PER APA TECHNICAL BULLETIN Q370 WHEN STUCCO LATH IS ATTACHED DIRECTLY TO OSB OR PLYWOOD.. SHOULD BUILDER SPECIFICATIONS ALLOW, MIN STRUCTURAL RE REQUIREMENTS ARE 24/16 SPAN RATING INSTALLED HORIZONTALLY OR VERTICALLY PER FLEXIBLE VENEER WALL Q /6 SPECIFICATIONS. INCLUDES FULL AND PARTIAL HEIGHT VENEER APPLICATIONS. 7. 1%2" PLYWOOD IS A WARRANTY LIMITATION COMMON TO TILE MANUFACTURER'S MINIMUM RECOMMENDATIONS. SHOULD WARRANTY AND INSTALLATION REQUIREMENTS ALLOW, 1V32" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF. 8. WOOD STRUCTURAL PANEL MAY BE INSTALLED VERTICALLY OR HORIZONTALLY W/ UNBLOCKED HORIZONTAL PANEL EDGES. 9. ROOF DECK SHEATHING HAS BEEN ENGINEERED TO RESIST ASCE 7-16 WIND LOADS IN ACCORDANCE WITH FRC R301.2.2.1 TABLE 4: NAIL SIZE LEGEND TABLE 5: FASTENERS IN NOTES 1, 2, 3, 4-11 DIAMETER LENGTH PRESSURE TREATED LUMBER 8d COMMON 0.131" 2-'/2" RSRS-01 0.113" 2-%8' RSRS-03 0.131" 2-'/2" 10d 0.131" 3" 10d COMMON 0.148" 3" 12d COMMON 0.148" 3-%" 16d SINKER 0.148" 3-'/4" 16d COMMON 0.162" 3-1/2" 11 NOTES: 1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED. 2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS BEFORE APPLICATION OF PROTECTIVE COATING. 3. WHEN A BORED HOLE IS REQUIRED TO PREVENT SPLITTING OF A WOOD DUE TO FASTENER PENETRATION, THE BORED HOLE 0 SHALL NOT EXCEED 75 /o OF THE NAIL OR SPIKE DIAMETER. 4. THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4. PRESERVATIVE FASTENER TYPE ACZA STANDARD CARBON STEEL SODIUM BORATE (NOTE 1) STAINLESS CONNECTORS AND FASTENERS REQUIRED. CONNECTORS MUST HAVE Z-MAX, G120 OR TRIPLE ZINC ALL OTHER PT COATED FINISH. (INCLUDING ACQ & MCQ) ALL FASTENERS MUST BE HOT DIPPED GALVANIZED. NOTES: 1. SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY EXPOSED TO EARTH OR WEATHER AND HAVE BEEN PROVEN TO BE NON -CORROSIVE TO CARBON STEEL FASTENERS. CONCRETE AND FOUNDATION NOTES 1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTINGS= 2,500 PSI AT 28 DAYS (UNO). 2. CONCRETE COMPRESSIVE STRENGTH FOR SLAB = 2,500 PSI AT 28 DAYS (UNO). 3. ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO). 4. ALL REINFORCING STEEL SHALL HAVE 90 DEGREE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE INSTALLED AT ALL REENTRANT CORNERS. 5. FIBERMESH IS AN ACCEPTABLE ALTERNATIVE AND SHALL NOT REQUIRE WWF. FIBER LENGTHS SHALL BE'/i' TO 2" IN LENGTH. DOSAGE AMOUNTS SHALL RANGE FROM 0.75 TO 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE CERTIFICATION OF COMPLIANCE WHEN REQUESTED BY THE BUILDING OFFICIAL. 6. MASONRY STEMWALL AND MONOLITHIC FOOTING ARE INTERCHANGEABLE. 7. EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 PSF IN ACCORDANCE WITH TABLE R401.4.1, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS, 8. CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WITH CODE APPROVED PROVISIONS FOR PREVENTION OF SUBTERRANEAN TERMITES. 9. STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION. CONTACT ENGINEER OF RECORD IF THIS CONDITION EXISTS. 10, TO CONTROL CRACKING, CUT 1" SAWCUTS IN THE SLAB IN A 15'x15' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT. CONTACT FOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NOT REQUIRED WHEN WWF OR FIBERMESH ARE INCLUDED WITH CONCRETE WORK. 11. DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DO NOT DETERMINE FOOTING LOCATION FROM ARCHITECTURAL PLANS OR FRAMING PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINATE FROM USE OF FOUNDATION PLAN ALONE, CONTACT THE ENGINEER OF RECORD. PRE-ENGINEERED TRUSSES & I -JOISTS 1. ROOF TRUSS TOP CHORDS SHALL HAVE A MINIMUM SPECIFIC GRAVITY OF 0.49 (SYP SPECIES OR BETTER). 2. ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS SHALL BE PREPARED IN ACCORDANCE WITH ANSI/TPI AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION. DESIGN CRITERIA IS LOCATED ON SHEET ST-1 OF THE PLAN SET. TEMPORARY BRACING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE. 3. TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION, SPAN DIRECTION, SPACING, BEARING LOCATION AND NAMING CONVENTION OF THE LAYOUT SHOWN HERE. 4. THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS. 5. TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN OF THE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE. AS SUCH, THE REPORTED UPLIFTS ON THE TRUSS SHOP DRAWINGS MAY BE DISREGARDED. 6. I -JOISTS FABRICATED TO ACHIEVE THE FLOOR PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SEE DESIGN CRITERIA, THIS SHEET. TABLE 7: METAL CONNECTOR SCHEDULE NOTES 2- 3- 4 USP & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOW ARE EQUAL ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE SIMPSON SIMPSON FASTENERS MITEK USP FASTENERS SIMPSON SIMPSON MITEK USP FASTENERS FASTENERS (8)% X 1 /2 SIDS SCREWS () (8)%" x 1 %" WS15-GC DTT2Z IN STUD /2" 0 X 4 /2" WOOD SCREWS IN STUDDTB-TZ (9) 10d COMMON (9) 10d (NOTE 2) EMBED EPDXY OR '/2 0 x 4'/2" EMBED EPDXY CS18 EACH END CS20 COMMON SCREW ANCHOR OR SCREW ANCHOR EACH END (18)0.162"x2'/2"IN (18)0.162"x2 WIN HTT4 STUD/BEAM/TRUSS STUD/BEAM/TRUSS (7) 10d x 1 1/2" (7) 10d x 1 1/2"(NOTE 2) �8" 0 x 6" EMBED ANCHOR HTT45 §8" 0 x 6" EMBED ANCHOR MTS12 EACH END MTW12 EACH END IN CONCRETE IN CONCRETE (26) 0.162" x 2 'Y2" IN (26) 0.162" x 2 Y2" IN HTT5 STUD/BEAM/TRUSS STUD/BEAM/TRUSS (9) 10d COMMON (9) 10d COMMON (NOTE 2) �8" 0 x 6" EMBED ANCHOR HTT45 48" 0 x 6" EMBED ANCHOR MSTA24 EACH END MSTA24 EACH END IN CONCRETE IN CONCRETE (20)%" x 3" SIDS SCREWS (24) 3" WS IN STUD HDQ8-SDS3 IN STUD GROUP PHD8 GROUP 7/8" 0 x 12" EMBED MSTA36 (13) 10d COMMON MSTA36 (13) 10d COMMON 7/8" 0 x 12" EMBED ANCHOR IN CONCRETE EACH END EACH END ANCHOR IN CONCRETE (7) 10d COMMON IN (7) 10d COMMON IN (7) 10d x 1 '/2" IN TRUSS (7) 10d x 1 '/2" IN TRUSS META12 4" WET EMBED IN HTA16-18 4" WET EMBED IN MSTAM36 WOOD FRAMING MSTAM36 WOOD FRAMING GROUTED BLOCK WALL GROUTED BLOCK WALL (4) '%' x 2 '%' TITEN (5) '/4" x 2 '/4" TAPCON IN SCREWS IN MASONRY (11) 10d x 1 %' IN MASONRY (1 1) 10d x 1 '/2" IN (8) 10d x 1 '/2" IN TRUSS (9) 10d x 1 '/2" IN TRUSS META20 4" WET EMBED IN HTA20-18 4" WET EMBED IN HTS20 TRUSS/RAFTER HTW20 TRUSS/RAFTER GROUTED BLOCK WALL GROUTED BLOCK WALL (11) 10d x 1 '/2" IN (11) 10d x 1 %" IN STUD (12) 10d x 1 1/2" IN STUD (8) 10d x 11/2" IN ABU44 (12) 16d COMMON NAILS PAU44 (12) 16d COMMON NAILS HTSM20 TRUSS/RAFTER HTWM20 TRUSS/RAFTER (NOTE 6) 48" 0 x 7" EMBED EPDXY 4g 0 x 7" EMBED EPDXY (12) 10d x 1 1/2" IN (4) Y4" x 3" WEDGE BOLT STUD (5) 8d x 1'/2" IN OR EQUIVALENT IN STUD (5) 8d x 11/2" IN (12) 16d COMMON NAILS (12) 16d COMMON NAILS ABU66 4 " 0 x 7' EMBED EPDXY PAU66 4 " 0 x 7' EMBED EPDXY 8 H2.5T/ TRUSS RT7/ TRUSS (NOTE 6) (12" EMBED AT GARAGE (12" EMBED AT GARAGE HA8 (5) 8d x 1 Yz" IN RT7AT (5) 8d x 1'/z" IN DOOR RETURNS) DOOR RETURNS) TOP PLATE (5) 10d x 1'/2" IN TOP PLATE (5) 10d x 1'/2" IN HU48, (14) 16d COMMON IN HD48, (14) 16d COMMON IN H UC48, HEADER HD481 F, HEADER H8 TRUSS RT8A TRUSS HU28-2, HUC28-2 (6) 10d COMMON IN BEAM HD28-2, HD28-21F (6) 10d COMMON IN BEAM (5) 10d x 1 Y2" IN TOP PLATE (5) 10d x 1'/2" IN TOP PLATE (16) 10d COMMON TO HU410, (18) 16d COMMON IN HD410, (18) 16d COMMON IN HUC410, HEADER HD4101F, HEADER TRUSS/RAFTER TRUSS/RAFTER HU210-2, (10) 10d COMMON IN HD210-21 (10) 10d COMMON IN LGT2 (7) %" x 2 %" TITEN LUGT2 (5)'0" x 3" WEDGE BOLT HUC210-2 BEAM HD210-21F BEAM SCREWS IN MASONRY (26) 16d SINKER OR EQUIVALENT (28) 16d SINKER IN WALL (22) 16d COMMON IN (22) 16d COMMON IN HUC212-2 HEADER HD212-21F HEADER 10 10d COMMON IN BEAM 10 10d COMMON IN BEAM LGT3 IN WALL FRAMING (12) SIDS ''/4" x 2 '/2" LUGT3 FRAMING (12) WS25 ''/4" x 2 'Y2" (4)%" x 1 'Y2" SDS SCREW (4)'/4" x 1'/2" WS15 SCREWS IN TRUSS IN TRUSS IN TRUSS/RAFTER IN TRUSS/ RAFTER HGA10KT (4)%" x 3" SIDS SCREWS HGA10 (4) '/4" x 3" WS3 SCREWS IN TOP PLATE IN TOP PLATE SDWC14500, SDWC15600 NO USP EQUIVALENT (4) SIDS %" x 1 %" SCREWS (4)'/4' x 1'/2" WS15 SCREWS HGAM10KTA IN TRUSS/RAFTER '/4 HGAM10KT IN TRUSS/ RAFTER (4)'/4' x 13/4" WEDGE BOLT (4)' x 23/4" TITEN SCREWS IN MASONRY OR EQUIVALENT IN MASONRY NOTES: 1. REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS. 2. PRODUCTS SELECTED USING SIMPSON 2019-2020 CATALOG. PRODUCTS MAY BE SUBSTITUTED WITH EQUAL OR BETTER APPROVED ALTERNATES 3. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS. 4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT FOR FOR SPECIFIC FASTENING REQUIREMENTS. 5. POSITIVE PLACEMENT GUN NAILS, 2'/2" LONG, WITH EQUIVALENT DIAMETER TO COMMON NAILS SPECIFIED ABOVE MAY BE USED FOR ABU POST BASE ANCHORS, CS16, AND MSTA FLAT STRAPS. 6. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES Y4" 0 x 2 3/4' TITENS ILO 16d. CONCRETE REQUIRES EQUIVALENT NUMBER OF 0 x 1 3/4' TITENS ILO 16d. MASONRY NOTES 1. ALL MASONRY UNITS SHALL HAVE fm = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL BED. 2. SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER TYPE HORIZONTAL JOINT REINFORCEMENT 3. ALL GROUT TO MIXED PER ASTM C476 STANDARDS. fc = 3,000 PSI. 4. VERTICAL WALL REINFORCING TO BE ASTM A615 GRADE 60 REBAR. 5. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO BE 30". 6. VERTICAL REINFORCING TO HAVE 10" STANDARD HOOK INTO BOND BEAM. DOWEL TO HAVE 10" STANDARD HOOK INTO FOOTING 7. PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET. 8. PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE. >O _w N � LEGEND oLL OR "OR" SHALL MEAN THAT EITHER OPTION PROVIDED IS AN EQUAL ALTERNATIVE FOR THE APPLICATION SHOWN E LINO UNLESS NOTED OTHERWISE ON PLAN OR DETAIL FOR ENGINEER OF RECORD EW EACH WAY O C" Cr OSB ORIENTED STRAND BOARD p WSP WOOD STRUCTURAL PANEL Oc SYP SOUTHERN YELLOW PINE AP EX SPF SPRUCE -PINE -FUR N U CONT CONTINUOUS 00 N O.C. ON CENTER LSL 1.55E TIMBERSTRAND LSL ENGINEERED LUMBER, 1 3/4" WIDE, LINO. 00) (3 %" WIDE LSL BEAMS ARE EQUIVALENT TO 2-PLY 1 3/4" BEAM) LVL 2.0E MICROLLAM LVL ENGINEERED LUMBER, 1 3/4" WIDE PSL 2.0E PARRALLAM PSL ENGINEERED LUMBER, 3 '/2" WIDE, LINO. (V SYS 42 PROPERLY RATED OPEN WEB HEADER Q INTERIOR ROOF LOAD BEARING WALL, SPECIFICATIONS OUTLINED ON TYPICAL WALL SECTIONS, DETAIL SHEETS IL tds LLI INTERIOR BEARING WALL WITH NO UPLIFT. NO UPLIFT ANCHORS REQUIRED. MINIMUM J -6 BOTTOM PLATE ANCHORAGE IS 1/2" ANCHOR @ 8'-0" O.C. (UNO ON FRAMING PLAN OR $i t.;€, 1es€fin studio >� > SW SPECIFICATIONS) z O STRUCTURAL WOOD BEAM CA U 9000 REGENCY SQUARE BLVD. STUD COLUMN KEYNOTE Q SUITE 100, JACKSONVILLE, FL 32211 NUMBER OF SDWC15600 CONNECTING TOP PLATE TO STUDS. O O NUMBER OF STUDS BELOW BEAM/GIRDER TRUSS. STUDS t07 O4_ 2 2 STUDS U) Ir w �o 2 ANCHOR TO MATCH WALL FRAMING SIZE AND GRADE, LINO, W ADDITIONAL CLARITY FOR THE LOCATION OF THE STUD COLUMN ~ U) BOTTOM OF STUD COLUMN CONNECTION 1ST LEVEL STUD COL H REQUIRED AT BASE OF COLUMN COLUMN: N O LDDOWN QU J 2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL COLUMN TO 1ST LEVEL STUDS/HEADER/BEAM. m "ANCHOR" REQUIRES BOTTOM PLATE ANCHOR WITHIN 3" OF STUD COLUMN W NUMBER OF SDWC15450 CONNECTING STUDS TO BOTTOM PLATE W' a HEADER STRAPPING KEYNOTE � NUMBER OF STRAPS CONNECTING HEADER TO JACK STUD 1 MSTA24 TYPE OF STRAP CONNECTING HEADER TO JACK STUD U 1 DTT2Z KING/JACK GROUP BOTTOM CONNECTION z W 1 ST LEVEL STUD GROUP: HOLDDOWN REQUIRED AT BASE OF STUD GROUP (D 2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL STUD LU GROUP TO 1ST LEVEL STUDS/HEADER/BEAM. 0� NUMBER OF HOLDDOWNS/STRAPS AT BASE OF KING/JACK GROUP O O NON -BEARING HEADER FRAMING KEYNOTE NO HDR - # NUMBER OF KING STUDS EACH SIDE OF OPENING ti LO HEADER MAY BE FRAMED AS NON BEARING HEADER DUE TO LIGHTLY I` LOADED CONDITIONS ABOVE b Z #2 SYP HEADER FRAMING KEYNOTE (2) 2x10 - 1 / 2 NUMBER OF KING STUDS EACH SIDE OF OPENING (n (O w NUMBER OF JACK STUDS EACH SIDE OF OPENING z D DEPTH OF LOAD -BEARING #2 SYP HEADER NUMBER OF PLIES IN HEADER m ENGINEERED LUMBER HEADER FRAMING KEYNOTE W W (2) 9'/2' LSL- 1 / 2 NUMBER OF KING STUDS EACH SIDE OF OPENING Z 0 NUMBER OF JACK STUDS EACH SIDE OF OPENING Z HEADER MATERIAL (LSL, LVL. PSL, OR SYS42) W DEPTH OF LOAD -BEARING EWP HEADER Q 0 NUMBER OF PLIES IN HEADER (1 3/" WIDE UNO) HEADER FRAMING ° J L- 1. ALL HEADER JACK AND KING STU IDS SHALL BE FASTENED TO EACH OTHER WITH (2) ROWS 10d @ 8" O.C. Z STAGGERED. 0 2. NON BEARING HEADERS: DUE TO LIGHTLY LOADED CONDITIONS, 49" OR LESS CLEAR -OPENINGS IN AN EXTERIOR WALL DO NOT REQUIRE LOAD BEARING HEADER, SEE PLAN. Q 3. FASTEN ALL MULTI -PLY HEADERS TOGETHER WITH (2) ROWS 10d @ 8" O.C., STAGGERED ALONG EACH EDGE. 0� 4. FASTEN ALL HEADERS TO KING STUDS WITH (3)8d TOE NAILS . O 5. IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECORD. 0- 6. LINO ON PLAN. MIN (1) SDWC15600 TOP PLT TO KING STUD AND (1) SDWC15450 KING STUD TO BOTTOM PLATE W' CONNECTION REQUIRED EACH SIDE OF OPENING (NO CONNECTION REQUIRED FOR OPENINGS AT FIRST C) FLOOR HEADER WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE. 7. TOP PLATE TO HEADER CONNECTION PER ONE OF THE FOLLOWING (NO CONNECTION REQUIRED FOR OPENINGS 39" OR LESS, OR AT FIRST FLOOR HEADERS WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE: • SDWC15600 @ MAX 32" O.C. AS SHOWN, "ALTERNATE SECTION (HEADERS),ST-5 0� • SPH w/ (12) 10d x 1-%" @ 16" O.C. OR 0 • DSP w/ (14) 10d x 1-'/2" @ 16" O.C. OR LL • FASTEN TRUSS DIRECTLY TO HEADER w/ MTS OR HTS w/ (14) 10d x 1 %" (OR EQUAL APPROVED BY EOR). Q 8. CRIPPLE BLOCKS BELOW LOAD -BEARING HEADERS MAY BE FRAMED AT 24" O.C. U z FRAMING NOTES 0 0 1. SIMPSON ACRYLIC -TIE ADHESIVE OR EQUAL SHALL BE USED IN ALL DRILLED AND EPDXIED ANCHOR APPLICATIONS. ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCING STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN O A HOLE AS SPECIFIED BY MANF (TYPICALLY 1/16" TO 1/8" GREATER THAN SPECIFIED ANCHOR DIAMETER). Z ADHESIVE/EPDXY MUST FILL THE HOLE IN THE CONCRETE AND WOOD BOTTOM PLATE. MANUFACTURER'S = SPECIFICATIONS MUST BE FOLLOWED FOR PROPER INSTALLATION. U 2. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY, UNO. ALL WATERPROOFING AND FIRE SAFET LLJ SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER. x 3. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN W TABLE 2304.10.1 W 4. BEAMS IDENTIFIED BY NUMBER ON PLAN ARE TO BE PROVIDED BY TRUSS MANUFACTURER OR LUMBER SUPPLIER. Q 5. FASTEN ALL MULTI -PLY STUD COLUMNS AND CORNERS TOGETHER WITH (2) ROWS 10d @ 8" O.C. STAGGERED. x UPPER LEVEL MULTI -PLY STUD GROUPS BELOW ALL GIRDER LOCATIONS TO BE CONTINUOUS THROUGH FLOOR Q SYSTEM TO FOUNDATION. (NOT REQUIRED BELOW HEADER JACK/KING STUD GROUPS) 6. FASTEN ALL STUDS TO BOTTOM AND TOP PLATES WITH (4)8d TOE NAILS OR (2)16d COMMON END NAILS. m 7. FASTEN ALL TRUSSES AND RAFTERS TO TOP PLATES WITH (3)8d TOE NAILS. 8. ALL MULTI -PLY TRUSS GIRDERS AND BEAMS TO HAVE SOLID STUD GROUP BELOW MATCHING GIRDER OR BEAM THICKNESS AND MATCHING WALL STUD SPECIFICATIONS AS NOTED ON STRUCTURAL PLAN, LINO. Uj 9. EXTERIOR WALL DESIGN ASSUMES CONTINUOUSLY SHEATHED WITH OSB OR PLYWOOD Z O LU z U) O F- F_ LL U) C7 O J O U w x w a Q CMUIMETAL CONNECTOR ENGINEERING Rik u� U-n-HORION" e ,.4 ' 0 z..... s. a r, 5 ;... "\ s .a .51 >Sof \o E± tz Q U) � a LU J O W co � Q o Q LLJ Q W LLJ x Q LL � z O 0 W F_ Z 0- LL W ABBOTT PARK Q W LOT 040-03 0 W - Q z (D PROJECT NO w 0 2021.006629 LL O DRAWN KME o CHKD Lf) MJP U) W J Q U ``ttllt111//�� IN LA�� , (n W �`�•�v5� �`, , •��G•E•NSF•q ,�'� Z No 85166 * cNF43.Signed by: LITADAFE b ••� ` nn �'��`�s•� 0R�,�P�j�`•`� Vrr z Q 05-18-2021 p w REVISIONS: No. Description Date w - -� J U i � U) H O z O 0 ST-1 )ocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 I 2020 V1.0 GENERAL FOUNDATION NOTES: 0. v 7 0 M 1,-4„ W11 FOUNDATION PLAN 1/4" = V-0" WHEN PRINTED ON 22"x34" 70'-0" 59'-10" F 3 0 70'-0" Ell V ib 0? N � M O zo • CONCRETE SLAB ON GRADE SHALL BE MINIMUM 3 1/2" THICK AND p HAVE MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI UNO. O • EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS N � ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 psf, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. N COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED 00 PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. O IF CONTRACTOR OR BUILDING OFFICIAL DETERMINES THAT THE SOIL IS NOT SUITABLE FOR 2,000 PSF BEARING CAPACITY, CONTACT ' EOR. ADDITIONAL FOUNDATION WORK MAY BE REQUIRED. r' • SLIDING GLASS DOOR FRAMES MUST BE RECESSED INTO THE SLAB N IN ACCORDANCE WITH THE BUILDING CODE. CONSULT C14 ARCHITECTURAL PLANS FOR LOCATION OF SLIDING GLASS DOORS. m • MASONRY STEMWALL AND MONOLITHIC FOOTINGS ARE J INTERCHANGEABLE. SEE SHEET ST-21D FOR ALTERNATE STEMWALL LL SECTIONS. Lij • 24" LONG #4 BAR IS RECOMMENDED TO BE INSTALLED AT ALL J RE-ENTRANT CORNERS, SEE "RE-ENTRANT CORNER DETAIL" ON J SHEET ST-21D. z O U) FOUNDATION KEYNOTES: DC1 Q NOTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN -� F - ` 8"x8" DEEP THICKENED ( 11 12" DEEP FTG UNDER BOX O A I EDGE w/ (1) #4 CONT I B I COLUMN, FTG TO BE PROJECTED MIN 6" AS SHOWN w F- C 16"SQx12" DEEP FTG D� 24"SQx20" DEEP FTG D w/ (3) #4 EW (1J E 30"SQx20" DEEP FTG F 36"SQx20" DEEP FTG 0 w/ (4) #4 EW _ w/ (4) #4 EW J m 48"SQx24" DEEP FTG #5 VERTICAL DOWEL TYP w G wl (5) #4 EW, T&B H_I AS SHOWN, SEE MASONRY NOTES ON ST-1 Q jj 1 1/2" SLAB EXTENSION AT FULL ROUGH U) OPENING WIDTH X z w (D w w C) (D O ***NOTE_ TO CONTRACTOR— DR HORTON DOES NOT ALLOW FIBERMESH AS AN ALTERNATIVE TO WWF AS SPECIFIED IN THIS PLAN SET LO ti r-: BORA-CARE OR OTHER DR HORTON APPROVED WOOD DESTROYING z ORGANISM TREATMENT TO BE APPLIED AS DIRECTED BYPRODUCT w MANUFACTURER AND DR HORTON. U) - w z co Cn w z z w 0 Of J ILL z O F- O Cl- O U Q 0 w O J LL Q z J O z U w F— w D_ Q x m 0 w z O w 2E z U) O F— ,� LL } C� SANITARY ISOMETRIC ° J APEX tds true design studios 9000 REGENCY SQUARE BLVD. SUITE 100, JACKSONVILLE, FL 32211 wHIH019ON' ABBOTT PARK LOT 040-03 PROJECT NO 2021.006629 DRAWN: - --- - KME CHKD MJP ,5�1N l,qo /��� No 85166 --Doc Signed by: -r. ('�� r O'•, E DA'2S7EF43.. 44/ -'1S j0 N A� -' . 05-18-2021 REVISIONS: No. Description Date >(D O z 2 U w F- x w Q CMUIMETAL CONNECTOR ENGINEERING ST=2 )ocuSign Envelope ID: 804C66C7-1A16-4461-A7C7-0002ED72E2B6 EXISTING EXTERIOR CMU MIN. 3" EDGE DISTANCE STRIP OF WWF FROM F.F.E. TO MIN. 6" BELOW GRADE. WWF TO -- EXISTING FOUNDATION FACE w/ ° D (2) ROWS OF 316" DIA. TAPCONS OR CUT NAILS @ 24" O.C. COVER FLUSH w/ 3000psi CONCRETE. EXISTING FOUNDATION. n D 8" CMU WALL OVERHANGS LESS THAN 1" CONCRETE SLAB W/ 6x6 W1A x W1.4 WWF OR FIBERMESH e ° a 12" UNDER 1 STORY WALL 16" UNDER 2 STORY WALL 0'-0" A.F.F. SEE ARCH — — — (MAX 20" d DEEP) d ° d 4 d Au //x 4" EXTENSION UNDER BRICK VENEER VAPOR BARRIER 6 BEARING CURB STEP SECTION I". CONCRETE SLAB w/ 6x6 W1.4 x W1.4 WWF OR FIBERMESH a VAPOR BARRIER 3 BEARING WALL FOOTING SECTION LAP #5 CONTINUOUS BAR AS NEEDED, MIN 12" LAP AS SHOWN NO.5 BAR BEND 90 DEGREE TOP OF FOOTING CONTINUOUS CONCRETE FOOTING, SEE PLAN TYPICAL STEP IN FOOTING DETAIL, CONCRETE SLAB W/ 6x6 W1.4 x W1.4 WWF OR FIBER MESH 8" CMU CHAIR TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. Y 1 W \\ o VAPOR BARRIER ��\\� //\/ w'o U cn X #4 OR #5 VERT REINFORCING UP TO 3 COURSES: 72" O.C. 4 TO 5 COURSES: 48" O.C. FOOTING TO BEAR ON FIRM —�\i/ /\\\ \\' -- ADDITIONAL #4 OR UNDISTURBED SOIL /' / #5 IN BRICK LEDGE VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN CAST -IN -PLACE FOOTING SPECS 1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT 2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT 2 STEMWALL SECTION 1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS MAY BE OBTAINED FROM THE ENGINEER OF RECORD. 2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. 0'-0" A.F.F. _ (BEYOND) FLOATING CONCRETE — w U-BLOCK W/ SLAB W/ 6x6 W1.4xW1.4 U OR #5 CONT WWF OR FIBERMESH > Q Q ow — — — e — U FINISH / ° B \/\ \ O GRADE // // // #4 OR #5 VERT REINFORCING --\\\�\\ UP TO 3 COURSES: 72" O.C. 4 TO 5 COURSES: 48" O.C. / FOOTING TO BEAR ON FIRM \/ /\ UNDISTURBED SOIL ADDITIONAL #4 OR #5 IN BRICK LEDGE VERT REINFORCEMENT TO 4" OPT BRICK LEDGE HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN CAST -IN -PLACE FOOTING SPECS 1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT 2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT 7 STEMWALL CURB SECTION 1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS MAY BE OBTAINED FROM THE ENGINEER OF RECORD. 2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. GROUT BOTTOM 3 COURSES OF EXISTING CMU WALL FOR LENGTH OF OVERHANG. FILL TO BOTTOM OF WINDOWSILL �, CMU STEMWALL MONO LITHIC SLAB 3'/2" CONCRETE SLAB W/ 6x6 WHERE NEEDED 8" CMU CHAIR BLOCK W/ (1) #5 (1) #4 OR #5 CONT. W1.4 x W1.4 WWF OR FIBERMESH CONTINUOUS TO EXTEND MIN 24" MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. INTO MONOLITHIC THICKENED EDGE MIN. 3" EDGE DISTANCE MIN 24" LAP 36" MAX VARIES PER — — — — — — 4 d — 4" CONCRETE SLAB W/ ARCH PLANS ° a6x6 W1.4 x W° ° STRIP OF WF FROM F.F.E. TO OR FIBER E1SHF /\/\ W u'r VAPOR BARRIER BOTTOM OF FTG. WWF TO EXISTING FOUNDATION FACE w/ ° _ - — — ° — w z — e //\\//\\// 12" MIN �` ° ° ° \ 3 D --° U) O °, $ ° ° #4 OR #5 � \/ UNDISTURBED SOILON FIRM 2 ROWS OF /6' DIA. TAPCONS OR CUT NAILS @ 24" O.C. COVER / D ° ° O z ° ° ° ° ° REINFORCING PER\'�\' FLUSH w/ 3000psi CONCRETE. > < ° MONOLITHIC FOOTING ° C d SECTION _ d 6" OPT. EXTENSION b ° IN BRICK LOCATIONS d EXISTING FOUNDATION ° e ° ° ° FOOTING TO BEAR ON FIRM ON FND PLAN UNDISTURBED SOIL 1 UNDER 1 STORY WALL W/ (2) d ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT o \ ° ° ° ° ° ° • ° ° MIN12" ///\\//\\/�\/��\///\\ BAR IN BRICK LEDGE 16" UNDER 2 STORY WALL W/ (3) i#4 OR (2) #5 CONT MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH 8 CMU WALL OVERHANGS 2.5 OR LESS //\\//\\//\\//\\//\\//\\//\\�/ /\\/�\\�� // STEMWALL FOOTING TO EXTEND MIN /��/\\/\\� \\/��\ \/ • ADDITIONA #412" BELOW OR VERTICATHIC L TO BE "NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" NOTES: \/\FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG • IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, /' /' LOCATED WITHIN TRANSITION ZONE LOCATE VERTICAL AND TIE INTO STEMWALL FOOTING DEPTH EXCEEDS 28". REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL REINFORCEMENT IN LAST REINFORCEMENT IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO STEMWALL CELL STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. TWO CHOICES: • IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, 1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION CONTACT EOR. CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL OF SOIL. 2. USE STEMWALL FOOTING CONCRETE SLAB W/ 6x6 W1.4 x W1.4 WWF OR FIBERMESH /�A 0 VAPOR BARRIER �x .� SEE NOTES (MAX 16") U STUCCO OR DIRECTLY ADHERED STONE CLADDING FINISH - MIN 6" a, 0 � o � ALL OTHER EXTERIOR WALL O CLADDING - MIN 8", U.N.O. ON ARCH O 0 \\ T APEX C k 11 ' M IN/ /\/\/\/\/\/ N c) � A� O FOOTING TO BEAR ON / 6" OPT. EXTENSION IN BRICK FIRM UNDISTURBED SOIL LOCATIONS ON FND PLAN N i 12" UNDER 1 STORY WALL w/ t` (2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J BAR IN BRICK LEDGE 16" UNDER 2 STORY WALL w/ V- W t d s (2) #5 OR (3) #4 CONTINUOUS J J z true design studios � > MONOLITHICFOOTI_NG SECTION 1 CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O FOLLOWING OCCUR: Y • OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. • GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 0 FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 PER S-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O 6 O 4- CONCRETE SLAB w/ 6x6 (2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR W Cy Cy FIBERMESH 0 0 ROHOMON . " � � ' f W rA 3 BEARING WALL FOOTING SECTION z W (D W CONCRETE SLAB W/ 6x6 w W1.4 x W1.4 WWF OR O FIBERMESH O 0'-0" A.F.F. O ° SEE ARCH e DETAILS ~ 8" MIN b V J a 8"x8" THICKENED 8" FTG AT Cn n/ STEP-DOWN, SEE VAPOR BARRIER W PLAN z z W 4 CURB STEP SECTION m Uj _O co Ilf -- -- W Z 8" UNDER MASONRY WALL -- 0 > O CONCRETE SLAB W/ 6" UNDER WOOD WALL - Z M Q Q 6x6 W1.4 x W1.4 WWF W WUj L� SEE ARCH < W 0 OR FIBERMESH VARIES d Q Q 2 -� - -- ° ' , ' - ° 4 d ° (MAX 16") L1J o \A�VAjVA� x /z�V// /�A�\ A// /��\/��V//V//V//V/V/\ I LLL 12" M I N\\/\\/\\/\\ Z VAPOR BARRIER /// ° a // / O \ Q / 6" OPT. EXTENSION IN BRICK 0 W LOCATIONS ON FND PLAN z 12" UNDER 1 STORY WALL w/ O a (2) #5 OR (2) #4 CONTINUOUS -- ADDITIONAL NO. 4 OR NO. 5 U LIL BAR IN BRICK LEDGE — 16" UNDER 2 STORY WALL w/ Q W (2) #5 OR (3) #4 CONTINUOUS —1ABBOTT PARK Q 5 EX_T WALL CURB SECTION L �GARAGF NTACTFOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 040-03LLOWING OCCUR: - ---- - • OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U • GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z z FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY _ PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. W PROJECT NO W CONCRETE SLAB W/ 6x6 O 2021.006629 0 W1.4 x W1.4 WWF OR O W FIBERMESH Z DRAWN O 0'-0" A. F. F. = KM E SEE ARCH U O -d — — ° — — — — (MAX 20" DEEP) cHKo: MJP X rA 4 W^ J ° • d LL U4" EXTENSION x UNDER BRICK VENEER w Q �•�`t�(1N Lq������i 12" UNDER 1 STORY WALL5' G•E N W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER co` .•'� `SF ••.• 0 Z o No 85166 16" UNDER 2 STORY WALL W * •:• * Q W/ (3) #4 OR (2) #5 CONT = L-Do�,Slqned by: = Q 0. Al 6 BEARING CURB STEP SECTION W o/�CT7EF43.•/,�` U),n ��� FS • 4 O R `•p • ��`�� Z z �'� S/0 N AL E�%N Zf TYPICAL REINFORCING BARS AT THICKENED FOOTING, SEE PLAN MIN 24" LONG #4 OR #5 BAR SET AT MID -DEPTH OF SLAB, TYP ALL I RE-ENTRANT CORNERS - - IL== — — HOUSE SLAB RE-ENTRANT CORNER DETAIL (RECOMMENDED) PLAN VIEW, DETAIL TYPICAL @ ALL RE-ENTRANT CORNERS cn O 05-18-2021 p W U REVISIONS: Q No. Description Date W U) _I - - U 1 O Z --- Z = O U W x W ST=2mD n Q CMU/METAL CONNECTOR ENGINEERING )ocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E266 • v 1, 0 1'-4" 4'-5" T-5" �3 AN - 5-0" • mil is T-0" 11 T-0" L 6-8" 6'-8" 6-8" L 6-8" 6-0" 64" �, 4'-8" 6'-8" ,�, 6'-8" ,�, T-0" �r 1ST LEVEL DOWEL PLACEMENT PLAN 1/4" = 1'-0" WHEN PRINTED ON 22"x34" GENERAL MASONRY NOTES DC1 • ALL LINTELS SHALL BEAR A MINIMUM OF 4" AT EACH END. 8U LINTELS MAY BE FILLED OR UNFILLED. • 8F LINTELS SHALL BE FILLED. LINTELS MAY BE CAST-CRETE PRECAST LINTEL OR EQUAL. DIMENSIONS ARE APPROXIMATE. MAX O.C. SPACING IS 6-8" O.C., U.N.O. SEE TYPICAL DETAILS FOR LINTEL INSTALLATION. MASONRY LINTEL AS NOTED, SEE PLAN AND SCHEDULE SPANS MAY VARY +/- 8" FOR ROUGH OPENINGS , MASONRY LEGEND NOTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN INDICATES GROUT FILLED CELL WITH NO REINFORCING ■ NO. 5 BAR w/ VERTICAL BAR IN FILLED CELL W/ MINIMUM 30" LAP REQUIRED, TYP AS SHOWN Oo (2) NO. 5 BAR w/ VERTICAL BAR IN FILLED CELL W/ MINIMUM 30" LAP REQUIRED, TYP AS SHOWN OPT. NO. 5 BAR APPLIES ONLY IF OPT OPENING INSTALLED o❑ NO. 5 BAR w/ VERTICAL REINFORCEMENT AT CMU COLUMN AS SHOWN, HEIGHT OF DOWEL = HEIGHT OF COLUMN FRAMING KEY NOTES (CMU) DC1 NOTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN (SEE SHEET ST-1 & 5 FOR TYPICAL NOTES) 1. MIN (2) INTERMEDIATE JACK STUDS REQUIRED BETWEEN OPENINGS. 2. SEE INTERIOR SHEARWALL DETAIL ON DETAIL SHEET. IN LOCATIONS WHERE INTERIOR SHEARWALLS HAVE VAULTED TOP PLATES, ALSO SEE INTERIOR SHEARWALL AT VAULTED TOP PLATE ON DETAIL SHEET. 3. ATTACH SW TO FLOOR DIAPHRAGM PER ONE OF THE FOLLOWING: A. IF FLOOR TRUSS ALIGNS ABOVE SW, ATTACH FLOOR TRUSS BOTTOM CHORD TO SW DBL TOP PLATE W/ 10d @ 3" O.C. B. FRAME AND SHEATH SW TO FLOOR DECK ABOVE. ATTACH FLOOR DECK TO SW DBL TOP PLATE W/ 10d @ 3" O.C. 4. HIGH UPLIFT CONNECTION: • FASTEN EVERY STUD TO TOP PLT w/ SP2 OR SDWC15600 @ MAX 16" O.C. • SECOND LEVEL WALL STUDS STRAPPED TO FIRST LEVEL WALL STUDS w/ MSTA36 OR CS18 @ MAX 48" O.C. (APPLICABLE ONLY w/ WOOD FRAMED FIRST LEVEL) FASTEN EVERY STUD TO BOTTOM PLT w/ SP 1 OR (2) SDWC15450 @ MAX 16" O.C. • TOP PLATE TO HDR W/ SDWC15600 @ MAX 16" O.C. 5. FASTEN EACH BEAM TO MASONRY W/ META12 I LINTEL SCHEDULE LINTEL NO. CLEAR SPAN LINTEL DESCRIPTION COMMENTS Z) U 0 N � O N O O O APEX N tJ 0o cu O cu m � cY1 N co _j LL W tds _I truedesigns studios � z O U U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 0 o O .- Wcy c� 0s✓ • •HOMON' N -� ` °> ° e Wt a air .w — m��r� . W IY <(, z W W O O O O ti ti z v J Z 0 Lll w i W -� z w m UJ Ow WLU Q W z 5 > o Lu m w 0 o Q J w W LLJ w OJ X LL Z `— O z O Q 0 w W 0- z w w O 0- U LL W ABBOTT PARK Q O U J (n LL LOT 040-03 0 Q W z z 0 O U) O PROJECT NO: W 0 J 2021.006629 O Z O L-1 16'-0" 8F-1-32 PRESTRESSED GARAGE DOOR L-2 3'-0" 8U8 L-3 2'-0" 8U8 L-4 6-0" 8F-16 L-5 8'-0" 9'-0" 817-16 8080 SGD/ REAR PORCH L-6 8F-16 REAR PORCH L-7 11'-8" 8F-16 REAR PORCH L-8 4'-8" 8F-12 FRONT PORCH (ELEV A) L-9 - 4'-8" 8F-16 FRONT PORCH (ELEV B,E,F) DRAWN. U KME o wCHKD: li) MJP c/) X W W Q Q U Q���'►�� a rr►��� W i CD No 85166 W Q Z * • DocNSigned by: •' O =.U: ��� 0 • '- 1 .. r. [�� + W O••, .:•: DA'2'DEF43 _4i, (n O 05-18-2021 p H W v REVISIONS: li Q No. Description Date W U) J � U O U) - O O z z O 2 0 U W X ST=3 W CMU/METAL CONNECTOR ENGINEERING )ocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 I _ I I I III I I _. _. I 1 st LEVEL FRAMING PLAN 1/4" = 1'-0" WHEN PRINTED ON 22"04" TRUSS FRAMING GENERAL NOTES SEE SHEET ST-1 & 5 FOR ADDITIONAL GENERAL NOTES • DRAFT STOPPING AT FLOOR TRUSSES TO BE PROVIDED BY BUILDER • UNLESS SPECIFICALLY NOTED ON TRUSS FRAMING PLAN, ALL TRUSS TO WOOD CONNECTIONS SHALL BE ACCORDING U 6 ri rn 0 N TO THE TYPICAL WALL SECTION, SEE SHEET ST-5. O O REFER TO COMPONENT MANUFACTURER'S LAYOUT FOR N TRUSS LABELS & DIMENSIONS OVERFRAMING NOTES 00 • ALL RAFTERS TO BE MIN. 2x6 NO.2 SYP @ 24" O.C. MAX. d • ALL "SLEEPERS" TO BE PLANK -ORIENTED 2x8 NO.2 SYP MIN. • FASTEN "SLEEPERS" TO EACH TRUSS/RAFTER W/ (3) 16d COMMONS MIN. • EACH RAFTER TO "SLEEPER" W/ SIMPSON H3 UPLIFT N CONNECTOR. N ALL RIDGE BOARDS TO BE 2 8 NO 2 SYP MIN ('') A • FASTEN 2x6 NO.2 SYP COLLAR TIES FROM RAFTER TO RAFTER WHERE APPLICABLE W/ (5) 10d COMMONS MIN. RAFTER SPAN SCHEDULE O.C. LUMBER SIZE SPACING 2x6 2x8 2x10 2x12 12" 15-5" 19'-11" 23'-9" 26-0" 16" 13'-4" 17'-3" 20'-7" 22'-0" 24" 10'-11" 14'-1" 16'-10" 19'-9" J U_ W J .J Z O 67 �e Q 20 L.L./15 D.L. #2 SYP C) CEILING JOIST SPAN SCHEDULE LUMBER SIZE SPOACING - 2x4 2x6 - 2x8 2x10 12" 12'-5" 19'-6" 25'-8" 26-0" 16" 11'-3" 1 T-8" 23'-4' 26-0" 24' 9'-10" 15'-6" ' 20'-1 23'-11" _ -- 10 L.L./5 D.L. #2 SYP TRUSS FRAMING KEY NOTES NOTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN 1. SEE "SHEAR PANEL" DETAIL ON DETAIL SHEET. 2. TYPICAL BEARING BLOCK • BEARING BLOCK TO BE NO.2 SYP, MIN 48" LONG AND TO MATCH DIMENSION OF TRUSS MEMBER. • ATTACH BEARING BLOCK TO TRUSS VERTICAL OR TRUSS BOTTOM CHORD W/ (3) ROWS 10d @ 4" O.C. STAGGERED. 3. LEDGER FRAMING NOTES • FASTEN NO.2 SYP LEDGER TO FRAMING/TRUSS VERTICALS AT EVERY SUPPORT WITH FASTENING SHOWN BELOW (MAX 24" O.C. SPACING), OR • FASTEN NO-2 SYP PT LEDGER TO MASONRY/CONCRETE w/ FASTENING SHOWN BELOW • ADDITIONAL FASTENERS MAY BE REQUIRED AT SPECIFIED LOCATIONS ON PLAN • SEE TABLE 5 ON SHEET ST-1/S1 FOR FASTENER PROTECTION AGAINST CORROSION • EXTERIOR DECK LEDGERS SHALL BE SECURE TO WALL FRAMING WITH WOOD SCREWS. COMMON NAILS AT FLOOR LEDGERS ARE FOR INTERIOR USE ONLY. ROOF FRAMING LEDGER TO WOOD: 2x6................................... (4) 12d COMMON 2x8...................................(6) 12d COMMON 2x10.................................(8) 12d COMMON 2x12._..............................(10) 12d COMMON LEDGER TO CMU (W/ 3" TAPCON OR TITEN)i PT 2x6.......(2) ROWS %4" 0 @ 24" O.C. STAGGERED PT 2x8.......(2) ROWS %4" 0 @ 16" O.C. STAGGERED PT 2x10..._(2) ROWS %4" 0 @ 8" O.C. STAGGERED PT 2x12.....(2) ROWS %4" 0 @ 6" O.C. STAGGERED FLOOR FRAMING LEDGER TO WOOD (W/ NAILS): 2x6...................................(3) 16d COMMON 2x8...................................(5) 16d COMMON 2x10.................................(7) 16d COMMON 2x12.................................(9) 16d COMMON W F- 0 J m W C� 07 } Z W (D W O O O O ti LO Z cn w w Z U) m W W Z Z W 0 O LL Z O I— Q a FLOOR FRAMING LEDGER TO WOOD (W/ SCREWS): LL Q PT 2x6...................... .._......... (3)'/<" x 4-'h" LONG #14 WOOD SCREWS U PT 2x8...................................(5) '/4' x 4-'/2" LONG #14 WOOD SCREWS Q PT 2x10.................................(7) ''/4" x 4-'/2" LONG #14 WOOD SCREWS 0 PT 2x12.................................(9) '/4" x 4-Y2" LONG #14 WOOD SCREWS O 4. ANGLE & LATERAL BRACES MAYBE OMITTED FROM GABLE JILLL BRACING DETAIL IF PORCH SHEATHING DETAIL IS Q PROPERLY APPLIED, SEE DETAIL SHEET ST-6/7. 5. IF USING (2) HTSM20, INSTALL (1) STRAP ON EACH FACE OF Z THE WALL - (2) HTSM20 ON SAME SIDE OF WALL IS NOT — PERMITTED AT THIS LOCATION } 6. • (1) 48" & (1) 24" BEARING BLOCK REQ'D 0 • EACH BLOCK TO TRUSS W/ (3) ROWS 10d @ 4" O.C. O STAGGERED Z • TRUSS TO MASONRY BELOW W/ LGT3-SDS2.5 2 w F- x w a Q x Q m 0 LLj 0 w a Z O H i= IL Q U) } C� 0 O Z 2 U LLI F- x W d 0 tds.Q true design studios N 9000 REGENCY SQUARE BLVD. SUITE 100, JACKSONVILLE, FL 32211 11HOMON" \%X�14 1404 Q co Q W J z � UjO �vJl / 0 _I a �-2 Q 0 Q Q LL! 0 LLI W x Q U_ � Z O 0 W F- Z LL W ABBOTT PARK Q U Cn LOT 040-03 0 W F- Z (D U) PROJECT NO w 2021.006629 0 IL O DRAWN: KME o CHKD: MJP w J 4 U M LAIC/ � �i U' �.-`\C•E N S�•'9 '.� Z No 85166 Q Doc Signed by: .• ((��F - �'.�F•'c� OR 1�P'���:� Z ON A� Q 05-18-2021 0 w REVISIONS: No. Description Date ~ w J U U) 0 Z O 0 ST=3A CIA METAL CONNECTOR ENGINEERING DocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 TRUSS TO TOP PLATE, MOISTURE BARRIER) UNO: BETWEEN MASONRY AND • TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS W/ H8 OR H10 • TRUSS LENGTH </ 10 FT VERT. REINFORCING TO --/ W/ H2.5T OR RT7AT OR HAVE 10" STANDARD SDWC15600 HOOK INTO BOND BEAM • EVERY OTHER STUD TO TOP PLATE W/ SP2 OR SPT24 OR SDWC15600 - MAX 32" O.C. • EVERY KING STUD TO TOP PLATE W/ SP2 OR SPT24 OR SDWC15600 TYPICAL ROOF DECK SHEATHING. SEE TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1 TRUSS OR RAFTER TO BOND BEAM W/ META12 OR HTA16-18 W/ MIN (7) 10d x 1 Y2" IN TRUSS (NOTE: IF META12 OR HTA16-18 IS IMPROPERLY INSTALLED, ATTACH TRUSS TO BOND BEAM W/ HTSM20 OR HTWM20) FASCIA (SEE ARCHITECTURAL) PROPERLY WIND LOAD RATED SOFFIT MATERIAL CONTINUOUS @ PERIMETER. SEE TABLE 1: COMPONENT AND CLADDING DESIGN PRESSURES ON SHEET ST-1. (1) COURSE CMU BOND BEAM W/#5 CONTINUOUS WALL SECTION AT ROOF (COMMON HEEL CONDITION) (THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) • EVERY OTHER STUD TO BOTTOM PLATE W/ SP1 OR SPT22 OR SDWC15450 • EVERY KING STUD TO BOTTOM PLATE W/ SP1 OR SPT22 OR SDWC15450 2x_ NO. SPF OR BETTER @ MAX 16" O.C. BOTTOM PLT ANCHOR %" THREADED ROD ANCHOR W/ MIN 4" EMBED W/ NUT & WASHER IN SIMPSON ACRYLIC -TIE OR EQUIVALENT ADHESIVE @ MAX 48" O.C. OR '/2' WEDGE BOLT W/ MIN 4'/2' EMBED W/ WASHER @ MAX 48" O.C. BOTTOM PLATE ANCHOR NOTES EACH SILL PLATE SHALL HAVE A MIN. OF (2) BOTTOM PLATE ANCHORS. ■ INSTALL ANCHORS WITHIN 12" OF EACH END OF SEGMENT (BUTT JOINTS). INTERIOR LOAD BEARING WALL I� a ° a \\/\\ d \ /\ I a 7-7 EXTERIOR WALL 8" PARTIALLY GROUTED EXTERIOR CMU WALL W/ VERTICAL WALL REINFORCING PER STRUCTURAL PLAN, SHEET ST-3 OR ST-2A (IF APPLICABLE) TYPICAL WALL SECTION AT FOUNDATION (THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) PROVIDE DOWELS TO MATCH VERTICAL WALL REINFORCING W/ MIN 30" LAP (IF DOWEL IS OMITTED OR IMPROPERLY INSTALLED, DRILL AND EPDXY DOWEL OF EQUAL SIZE W/ MIN. 6" EMBEDMENT IN MONOLITHIC, 12" EMBEDMENT IN MASONRY) TYI ROOF -TO' CONNE( 2x NO 2 SYP BLOCKING TO FIT TIGHT BETWEEN TRUSSES, (3)10d TOE -NAIL @ EACH END, BLOCKING MAY BE OMITTED FOR HEEL HEIGHTS < 9" 3/4" BETWEEN TOP OF WOOD PANEL AND CENTER OF FASTENERS. MIN 1%2" EXPOSURE 1 PLYWOOD RIM @ RAISED HEEL TRUSSES INSTALLED WITH LONG DIMENSION PERPENDICULAR TO TRUSS END VERTICALS, ATTACH TO TRUSSES AND BLOCKING W/ 10d @ 3" O.C. FASCIA (SEE ARCHITECTURAL) PROPERLY WIND LOAD RATED SOFFIT MATERIAL CONTINUOUS @ PERIMETER. SEE DESIGN CRITERIA AND LOADS: C&C DESIGN PRESSURES ON SHEET ST-1. TRUSS OR RAFTER TO BOND BEAM W/ META12 OR HTA16-18 W/ MIN (7) 10d x 1 12" IN TRUSS (NOTE: IF META12 OR HTA16-18 IS IMPROPERLY INSTALLED, ATTACH TRUSS TO BOND BEAM W/ HTSM20 OR HTWM20) WALL SECTION AT ROOF (RAISED HEEL CONDITION) THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS GENERAL NOTES APPLICABLE TO ALL: FOR MISLOCATION FASTEN 2x6 NO. 2 S TO TRUSS W/ MIN (1 FOR MISLOCATION INSTALL NEW MAS( STRAP TO INSIDE F MISLOCATED TRUSS ANCHORS BLOCKING NOT SHOWN FOR CLARITY #5 CONT. a Q D (1) #4 OR #5 BAR AT CORNERS N WITH MIN. 25" LAP z_ #5 CONT. -o D 0 o o 8" CMU BOND BEAM BOND BEAM REINFORCING AT CORNERS ALTERNATE WALL SECTIONS & TYPICAL DETAILS 1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM (20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. 2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x NO 2 SYP PT. 3, ALL INTERIOR BOTTOM PLATES ARE TO BE 2x NO 2 SYP PT. 4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. 5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. 6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. 7, FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A 8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. 9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. (1) #c STEP DOWN TIE -BEAM U 0 N N N DIST. FROM DOOR JAMB MIN. SCREW DIST. FROM DOOR JAMB MIN. SCREW / WINDOW TO BLOCK LENGTH / WINDOW TO BLOCK LENGTH OR 11/4" PER MANUF, 3" 5" 11/2' 3 �4' 37 6 5„ 111116 33/4, 3 3/4, 6„ 2 j4, 33/4„ il TITEN OR TAPCONS SCREWS SEE TABLE ABOVE FOR LENGTH: • (2) ROWS W DIA. @ 30" O.C. STAGGERED • (2) ROWS %s' DIA. @ 24" O.C. STAGGERED DOOR JAMB OR WINDOW ATTACH TO 1x_ PER MANUFACTURER'S DETAILS DISTANCE FROM BLOCK TO DOOR JAMB OR WINDOW, SEE TABLE ABOVE (SHIM AS NEEDED TO PLUMB JAMB, DO NOT EXCEED 'W) 1x_ PT NAILER BUILT UP 2x_ATTACHED TO MASONRY, (1) PLY 1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL DRYWALL 8" CMU WALL TYPICAL DOORMINDOW JAMB TO BLOCK (TYPICAL FOR ALL MASONRY OPENINGS. UNO) AM1,11\ 0 U O O Cr APEX 0 0 N (D N i (i5 CV co J S� ``� LL t _C S J � true des, n studios > O U) U 9000 REGENCY SQUARE BLVD. Q SUITE 100, JACKSONVILLE, FL 32211 p o O W �a� �o ���a�a � �� co I` Cr. U)04RHO190N, N 3 f. Q ' =�$ t e w Q Q. U Q U Z W 0 W w O O O a) >= ti d O Q U)z LL] U U) < L.1_.J w W z z -J w 120 Lu O u) w Q W W Z_ > Q Q W m w o � W W Liw O J X ILL Z Z O O Q 0 rY w m _z 0 O a U LL ABBOTT PARK Q O U LL LOT 040-03 0 Q w I- C) a z z O U) O PROJECT NO w J 2021.006629 O ILL Z O DRAWN: U KME o w U0 CHKD: MJP x w w � J Q U ('• \N LgNf, .,�. U m �••� `C•E•N SF'.9 z 0 No 85166 W Q Zr = Dm,S,,gned by: = LU O'•• DA`E:'[1EF435•'•/,�` U) Al z �i�SS /0 N A E� .�`�� 3: Q O 05-18-2021 p 1— w U REVISIONS: Q No. Description Date W O 1— J Z Z = 0 U W H X W ST=5 n CMUIMETAL CONNECTOR ENGINEERING DocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 _'- �e UPLIFT CONNECTION PE TYPICAL WALL SECTION MOISTURE BARRIER17� -1 TYPICAL PORCH BY OTHERS CEILING BOARD PER . PLAN. SEE TABLE 2; SHEET ST-1 (PORCH CEILING BOARD) TYPICAL PORCH SHEATHING DETAIL AT MASONRY EXTERIOR WALL (THIS DETAIL IS REQUIRED AT ALL COVERED PORCHES UNLESS NOTED OTHERWISE) TOE -NAIL MIN 2x4 NO.2 SYP BLOCKING BETWEEN TRUSS TOP CHORDS W/ (3) 10d COMMQNS EACH END FASTEN 2x6 NO.2 SYP— DIAGONAL BRACE TO BLOCKING w/ (6) 10d COMMONS 2x6 NO.2 SYP DIAGONAL BRAC1= SEE PLAN • UP TO 8FT SINGLE 2x6 ONLY • UP TO 20 FT. 2x6 W/ 2x6 T-BRACE FASTEN 2x6 NO.2 SYP "T-BRACE" TO DIAGONAL BRACE w/ 10d COMMONS @ 3" O.C. BLOCK PANEL EDGES WITHIN 4'-0" OF GABLE TRUSS (EDGEWISE OR FLATWISE) ROOF DEC I PROVIDE PANEL EDGE BLOCKING FOR NON -DROPPED GABLE 64" OR AS SHOWN ON PLAN I ROOF DECK ROOF TRUSS OR RAFTER SUB FASCIA MOISTURE BARRIER BY OTHERS MASONRY LINTEL PER PLAN FASTEN ROOF DECK TO FRAMING @ 3" O.C. ON EDGE, 6" O.C. IN FIELD WITH RSRS-01 FASTEN (1) SIMPSON HGAM10 BRACE CONNECTOR FROM DIAGONAL BRACE TO CMU MOISTURE BARRIER BETWEEN MASONRY AND NON -PT LUMBER BY OTHERS GABLE ANGLE BRACING DETAIL (W/ HGAM10) 1) MAX. TRUSS SPACING = 24" O.C. 2021 V1.0 2) OUTLOOKERS, BLOCKING & CLIPS MAY BE OMITTED FROM OVERHANG PORTION OF DETAIL FOR NON -DROPPED GABLE TRUSSES W/ 9" OR LESS OVERHANGS. 2x4 SYP OUTRIGGER @ 24" O.C. CLIP TO GABLE TOP CHORD WITH (1) H2.5T w/ (10) 8d x 1 '/2" 2x4 NO.2 SYP BLOCKING BETWEEN OUTLOOKERS. FASTEN EACH BLOCK TO ROOF DECK WITH 8d COMMON @ 3" O.C. GABLE TRUSS WALL SHEATHING PER PLAN L OR T BRACE VERTICAL REINFORCEMENT PER TRUSS ENGINEERING MOISTURE BARRIER SHALL BE PROVIDED BETWEEN MASONRY AND ALL UNTREATED LUMBER GABLE TRUSS TO BOND BEAM W/ META20 @ 48" O.C. W/ MIN (7) 10d x 1 (NOTE: IF META20 IS IMPROPERLY INSTALLED, ATTACH TRUSS TO BOND BEAM W/ HTSM20 OR MSTAM36) TOP OF WALL TOP OF FINISH FLOOR SLAB &-1" ABOVE F.F.E. TOP OF GARAGE DOOR 6-1"ABOVE . F.F.E. 4'-9" ABOVE _ F.F.E. 2'4' ABOVE F.F.E. 0'-9" ABOVE F.F.E. TOP OF CURB F.F.E. J�— q_OF OPENING 2x6x12 PT —_ CENTER BUCK DIA. ANCHOR 2x4 PT TOP BUCK 2x6 PT BUCK EACH SIDE OF OPENING - PROVIDE (5) 46" DIA. J-BOLT OR LARGE DIAMETER SCREW ANCHOR w/ 5 '/2' EMBEDMENT AT EACH DOOR BRACKET, EACH SIDE OF DOOR. PROVIDE 1 ''/z" x 416" THICK WASHER w/ EACH ANCHOR. (1st BOLT TO BE 9" MAX. ABOVE CURB.) GARAGE DOOR JAMB DETAIL #5 CONT. v (1) #5 BAR AT CORNER W/ MIN. 25" LAP #5 CONT. a J L0 N z PRE -CAST LINTEL PER PLAN FILL BOTH LINTELS SOLID W/ CONTINUOUS POUR PRE -CAST LINTEL PER PLAN MITER -CUT LINTELS AT CORNER, CORNER TO BE TEMPORARILY SHORED FOR MIN (7) DAYS LINTEL REINFORCING AT CORNER VERTICAL BARS TO EXTEND TO TOP OF WALL AS SHOWN. MIN 6" BEND INTO BOND BEAM PRECAST LINTEL SEE PLAN — EXTEND REINFORCING TO END OF PIER W/ 6" BEND TO LAP WALL REINFORCING AS SHOWN. -- MIN (2) SOLID FILLED & REINFORCED CELLS W/ NO.5 VERT. BAR ADJACENT TO GARAGE DOOR OPENINGS. — NO.5 VERT. BAR IN FILLED CELL AT EACH END OF PIER — NO. 5 DOWEL TO MATCH EACH SOLID FILLED & REINFORCED CELL EXTENDING FROM FOOTING TO LAP WALL REINFORCING W/ MIN 25" LAP UNLESS NOTED OTHERWISE ON DOWEL & LINTEL PLACEMENT PLAN. MIN 6" BEND AT BOTTOM. CONCRETE FOUNDATION WORK PER PLAN \\\\\\\\\\\\\\\\ GARAGE SHEAR PIER TRUSSES NEEDING BRACING O Ocr O 0 04 APEX 00 N 4 _x O Q) O c6 cam- N N �'I M ILL.tds 1 W J _I �, true design studios Z O U U 9000 REGENCY SQUARE BLVD. LATERAL BRACING - MULTIPLE TRUSSES �( SUITE 100, JACKSONVILLE, FL 32211 0 1. ALL RESTRAINT LUMBER SHOWN SHALL BE 2x4 NO.3 SPF OR BETTER (UNO). O 2. SHOULD A SCENARIO ARISE THAT DOES NOT RESEMBLE THOSE INDICATED ABOVE, IMMEDIATELY O CONTACT THE ENGINEER OF RECORD FOR APPROPRIATE BRACING DETAILS. W 3. BRACING LUMBER SHALL INTERSECT THE WEBS OF THE BRACED TRUSS AT LOCATIONS INDICATED AS NEEDING BRACING ON THE INDIVIDUAL TRUSS DETAILS PRODUCED BY THE TRUSS ENGINEER. 4. ALL FASTENERS SHOWN ARE .131" x 3" LONG (UNO). V) o ® z� 5. DESIGNED PER BCSI-B3, MOST CURRENT EDITION. 0] T-BRACE FASTENED TO WEB W/ 10d AT 6" O.C. L-BRACE FASTENED TO WEB W/ 10d AT 6" O.C. SCAB BRACE FASTENED TO WEB W/ 10d AT 6" O.C. *IF (2) BRACES ARE REQUIRED, APPLY (1) BRACE TO EACH FACE OF WEB. BOND BEAM REINFORCEMENT w (SEE WALL SECTION) w T_. ° FILL SOLID TO BOND BEAM c) - _I WI Uj ) �I I 0 8 F - # - DEPTH OF LINTEL ASSEMBLY "d" GROUT FILLED LINTEL ASSEMBLY 8" PRECAST LINTEL. SEE PLAN. CONTINUOUS LATERAL RESTRAINT WEB ry BRACE SUBSTITUTE Q WEB MEMBER SPECIFIED 'ALTERNATE BRACING U) _ ' SIZE CLR T OR L SCAB F2x4 1 ROW 2 T (1)2x4 2x4 2 ROWS 2x6 (2)2x4 U Z 2x6 1 ROW 2x4 (1)2x6 W 2x6 2 ROWS 2x6 (2)2x4* (� 2x8 1 ROW 2x6 (1)2x8 W w 2x8 2 ROWS 2x6 (2)2x6* - -- - - O O O SINGLE TRUSS BRACING j 1. INDIVIDUAL WEB BRACING MAY BE USED WHEN CONTINUOUS LATERAL RESTRAINT (CLR) IS SPECIFIED ON A TRUSS DESIGN BUT AN ALTERNATIVE WEB BRACING METHOD IS DESIRED. O 2. INDIVIDUAL WEB BRACING MAY CONSIST OF T-BRACING, L-BRACING, OR z W SCAB BRACING. REFER TO CHART AND DETAIL FOR MORE INFORMATION. 3. INDIVIDUAL WEB BRACING MATERIAL TO BE SAME U) SIZE, SPECIES, AND / GRADE AS WEB TO BE BRACED. W 0 BOND BEAM ° 0,4REINFORCEMENT _ (SEE WALL SECTION) COURSING BELOW BOND BEAM MAY BE FILLED OR UNFILLED 8U8 0 LINTEL MAY BE FILLED OR UNFILLED 8" PRECAST LINTEL. SEE PLAN. 8U8 J z W m UU O C) L W QW z Z Q W m w o o p J w w2 d. J X ,. z Z O z BOND BEAM 0 J REINFORCEMENT Q 0 w �• (SEE WALL SECTION) W _j ~ _ 0 z LU FILL SOLID TO BOND BEAM O U) r- U LL Uj \,y' LINTEL REINFORCEMENT J ABBOTT PARK Q U 0 0 _I (n LL LOT 040-03 0 8 F -1 - # ► DEPTH OF LINTEL ASSEMBLY "d" #5 BOTTOM BAR TO EXTEND U z NO LESS THAN 1" BEYOND z BEARING AT EACH END } - GROUT FILLED LINTEL ASSEMBLY O PROJECT NO w 8" PRECAST LINTEL. SEE PLAN. O 2021.006629 ILL}} 8F-1-# = DRAWN O KME o U o , P_ CHKD MJP J I Q U Q`0%,►111111/I/1' (A ,���,�5 I.. LAl���9 �� 0 G•E N Z_ 0 Z W Z No 85166 Q Z _ * • Doc Signed by: •• O� 0 :�► 0 . �� W O •, DR2T7EF435,' /� U) Q O_ 05-18-2021 p W U REVISIONS: TYPICAL PRE -CAST LINTEL OPTIONS Q No. Description j Date W - W U) J — - -� C O z I W I- X W ST=6 d CMUIMETAL CONNECTOR ENGINEERING 2