Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
36046 Stable Wilk Ave
w ABBREVIATIONS A.B. Anchor Bolt F.P. Fireplace P.T. Pressure Treated Abv. Above F.O.M. Face Of Masonry Pwd. Powder Room A/C Air -Conditioner R. Foot/ Feet Red. Radius AD1 Adjustable Ftg. Footing Ref. Refrigerator A,F.F. Above Finished Floor FIX Fixed Req'd. Required A.H.U. Air Handler Unit ALT. Alternate Galy. Galvanized Rm. Room B.A. Base Cabinet G.C. General Contractor Rnd. Round BF Bifold Door G.F.I. Ground Fault Interrupter R/S Rod and Shelf Bk Sh Bookshelf G.T. Girder Truss SD. Smoke Detector Bm. Beam Hdr. Header S.F. Square Ft. Bot. Bottom Hgt. Height Sh. Shelves B.P. Bypass door HB Hose Bibb SHT Sheet BRG. Bearing Int. Interior S.L. Side Lights Cir. Clg. Circle Ceiling KNVaIi Kneewall S.P.F. Spruce Pine Fir CJ Control Joint K.S. Knee Space SSouthern Square Col. Column Laun. Laundry S.Y.P.. Yellow Pine Comm. Community Lay. Lavatory TB Towel Bar Comp. Compressor L.F. Linear Ft. Temp. Tempered C.T. Ceramic Tile LL Li Lintel Length Thik'n. Thicken D. Dryer LT. Laundry Tub T.O.B. Top of Block DB Door Bell Mas. Masonry T.O.M. Top of Masonry Dec. Decorative Max Maximum T.O.P. Top Plate Ded. Dedicated Outlet TR TOWEL RING Dbl. Double M.C. Medicine Cabinet Dia. Diameter Mfgr. Manufacturer TP TOILET PAPER Disp. Disposal Micro. Microwave Trans. Transom Window Dist Distance Min Minimum Typ. Typical D.S. Drawer Stack M.L. Microlam U.C. Under Counter D.V. Dryer Vent Mir. Mirror UCL Under Cabinet Lighting D.W. Dishwasher U.N.O. Unless Noted Otherwise Ea. Each Mono Monolithic V. Shower Valves E.W. Each Way N.T,S. Not to Scale VB Vanity Base Elec. Electrical Opn'g. Opening Vert. Vertical Elev. Elevation Opt. Optional V.L. Versalam Ext. Exterior Pc. Piece VTR Vent through Roof Exp. Expansion Ped. Pedestal w Washer FBC Florida Building Code PH PHONE W/ With Fin. Fir, Finished Floor P.L. Parallam W/C Water Closet F.G. ixed Glass PLF Pounds per linear foot WA. Wedge Anchor Fir. Floor Pit. HI. Plate Height Wd Wood Fdn. Foundation Pit Sh. Plant Shelf WP Water Proof Fir Svs Floor Svstem PSF Pounds per square foot REVISIONS 08-20-15 1.00 NEW BASE PLAN 12-08-15 2.0 F RAM E-WAL REVISIONS ILm IE F#il 14 lik 171tem 2575 INDEX OF DRAWINGS u SHEET DESCRIPTION oz r a z yl o�c Ui 00 2 605 cz g 4 0 U10= o -" 1 O.?v =� c=nt9�W� a u- 0 ;Z9Z0 w p is SHEET No. CS COVER SHEET 1 MAIN FLOOR PLAN 1.1 UPPER FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS F1 FOAM DETAIL 11] QW N } WU. t Q Z 4 MAIN ELECTRICAL PLAN 4.1 UPPER ELECTRICAL PLAN 5 ROOF PLAN 6 FOUNDATION PLAN 7 MAIN FRAMING PLAN aU 0. 7.1 ROOF FRAMING PLAN 8 LINTEL DETAILS SN STRUCTURAL NOTES SN1 DETAILS S3 STEM DETAILS S4 DETAILS S5 DETAILS S6 DETAILS ST STAIR DETAILS SS RETROFIT DETAILS D1 SECTIONS & DETAILS WP WATERPROOFING DETAILS PA1.0 PRODUCT APPROVAL NUMBERS PA1.1 PRODUCT APPROVAL NUMBERS PA1.2 PRODUCT APPROVAL NUMBERS PA1.3 PRODUCT APPROVAL NUMBERS MEAN ROOF 15 FT. HIGH TYPICAL FOR SINGLE STORY HOMES MEAN ROOF 30 FT. HIGH TYPICAL FOR 2 STORY HOMES THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID Notice to Builder & All Subcontractors It is the intent of Designer/Engineer listed in the titleblock of these documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Office at (407) 880-2333 immediately. No backcharges will be considered for reimbursement by the Designer/Engineer without advanced notification and approval by the Designer/Engineer. Payments will be made in accordance to the terms of the agreement. Z M — o Z(0 Z Q Z cn .E..� w �U — OW I(� C v , 1— o O �M U mti a) co LJJ Rig— 0) Cl) 020 = di UID LL co 0 -le Q a� �OQo u) 0 �a. rn Q o A N C B D C V7 Co O N �� LLuz gN r W W LLB WIN I °' £ Olum e� ID W ,n��u�.s.,� ,o�ES`st a To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 1f O 0 Z ®53 tom � Fes-+ M O Q�OLn a in Q(L)Io-Ln CC U Z E W O F- J � W d' oz �o za Za 5, Z . 0=)ZZ ¢ J WSc LLJ Z oZ 0 z U, } o az Z W Z -0 Ln W 0 o > N O U V Z �a �w o aY40 ►- ` �� 4 0 J XOU oo� Q ��o Z No go o� JLij Ln Bozo O �O Q Z QLUZ 00 Z 01 az o g = ¢z UJ r'n ,--i a to SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO. 10 O SHEET NO. CS *,YP @ 2 STORY D S3 H.B.T = 5-SH - r---------- - OPT, N 16" DEEP - - �----_—`_ ----- N 266 B.F I I I 24 24 1 REF' 2x6 WALL I 12'4" -8" I I I CD I I I R 2 68 00 I I I KITCHEN I I I = A O3 ' ' 8-8FLAT LG. I tr I I N EDGE OF SLAB 2" 1 Op___4]� I I . BEYOND WALL r I— > f 3, 38 38 ,3 CC S3 I w I O w I 1 I 1 I I — ----- - -- —- 11------------I I- . M�� 1 w I 1 I 1 I GC 0 m o LJ_ 1.0 T w X I I 4'-0" 6-2" 6-6" 4'-8" 20'-8" I I I r 2 CAR GARAGE I I I r DINING ROOM 8 -8 FLAT CLG. I I I PATIO IT I I I 0 8'-8" FLAT CLG. I I I CARPET BUILDER TO PROVIDE I I I O 0 00 2'-6" L. APPLIANCE PROTECTION I I I o WHEN REQUIRED PER FBC I I I U) I I I (3 2X4 / L-------- — — �, r 3)16 TOEW ILS S3 4'-0" -0" N (3) 2X4 #2 SPF W/ W HAS 4 (3)16d TOENAILS @ b o BASE _---_-- TYP 2 STORY H H H �I �I S3 I FOYER i @ _ 3068 c2)#5'S J o O1 o T O O O 1 $ -8 FLAT CLG. S6 ui LL LL TILE O j �? 0 16 $„ 3'-8„ 3,_8„ T-6„ 6'_0" ,-2„ i 1 rn TRI11 1 r 2068 B.F. I V-13" FLAT CL HDR AT T-4" — — — q 0 2., 5-SH r r A§ MILL 4'-0" (2) #5'S N _ Cl?FO I M OA LO G S3 � P O (3) 2X4 #2 SPF V-8 FL T G.1 FLEX FAMILY ROOM 16d 8'-8" FLAT CLG. T NAILS3) TOENAILS @ 12 CARPET � O V-8" FLAT CLG. BASE _ _ _ in "' 00 CARPET 42 SLOPING 11 00 T _ _ _ HALF WAL 010 FLOOR G.T. 9 -ate') c— 00 — - — — -- COND. COND. I I 13 14 15 I I I8 I I I IUP h6R1 I I M `� I I I I I G M I I I I I IS3 1 TYP @ 2 STORY J S6 H.B.�.. J S6 TYP @ 2 STORY (3) 2X4 #2 SPF W/ (3)16d 1 TOENAILS @ BASE 8 HEADER SCHEDULE MARK HEADER SIZE REMARKS H1 (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE H2 (2) - 2X8 #2 SYP W/ 112" FLITCH PLATE H3 (2) - 2X10 #2 SYP W/ 1/2" FLITCH PLATE H4 (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE H5 (2) -1 3/4" X 11 114 LVL 2.0E Fb=2950 H6 (2) - 1 314" X 91/4" LVL 2.0E Fb=2950 H7 (2) - 1 3/4" X 16" LVL 2.0E Fb=2950 HS (2) -1 3/4" X 71/4" LVL 2.0E Fb=2950 (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED ** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20X26 18JX25i S.H. 13 20X381 18JX37j S.H. 14 20 X 50 1 18 J X 50 S.H. 15 20X63 18#X62j S.H. 16 20X72 18jX71j S.H. J 32 27 114 X 26 26 X 25 j S.H. J 33 27 1/4 X 38 j 34 27 j X 50 1 N/A S.H. J 33 N/A 26 x 37 1 S.H. J 34 N/A 26 x 50 S.H. J 35 27 1 X 63 26 X 62 1/2 S.H. 36 27 1 X 72 26 X 71 1/2 S.H. 22 37 JX26 36 jX251/2 S.H. 23 37 j X 381 36 j X 37 314 S.H. 24 37 j X 50 1 36 J X 50 S.H. 25 37 J X 63 36 j X 62 1/2 S.H. 26 37jX72 36JX711/2 S.H. DOUBLE 2 WIDE 75" TALL 73 J WIDE S.H. 32 54 X 26 52 j X 25 j S.H. 33 54 X 381 52 J X 371 S.H. 34 54 X 501 52 j X 50 S.H. 35 54 X 63 52 j X 62 j S.H. 36 54 X 72 52 j X 71 j S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 1 3/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors, equipped with self -closing device. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or class1 duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.11, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 518" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is Iocated.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" �A +25.6 / -27.8 W +25.6 / -34.3 +24.5 / -26.7 nD +24.5 / -31.9 �E +23.0 / -25.2 FO +23.0 / -28.9 GG SEE SN SHEET 1/"_u�JSEE SN SHEET MOC14OMPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALL LEGEND TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "B" 1ST FLOOR LIVING AREA 1093 2ND FLOOR LIVING AREA 1489 LIVING TOTAL 2582 GARAGE 427 FRONT ENTRY 35 TOTAL AREA 3044 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION R-11/R-13 KRAFT FACED (GARAGE / LIVING) z_o Z � Z Q CL z cn -I—� w C) U — Ow Imo^^ v ' = (� o in o rM m U LU I— E — v �M C 4V co E2 v M 0 0.20 2 ai v r- L00 � 4)) CY Q CL to 0""rn Q o N• C B D C Hula', ` C ``aikA@`° ✓ ' O ` Z U) CA O > LL .''� Z". v u) rn � ••t\ •. o�Q # aL] Z A J'f Sti%Is 1111 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 Z it OH cu N M O Q 'fU Lr) °- V Q U_ [IC V C) 00 z z E W J�~ 0 �o za < z a Z80 zLuz �¢ o-Z z a0� J W � N oWo Z zZ Ln Cr 0 }o Z Z Z 'gyp O.__I L 1 V-- o N t- C1 V z he¢O U J' uw1QOU Ud mS ly- n � a Z LLJ 0 J Z Q ~ Z W N Ln o o D UJI RQ5 o Wo CD l0 2:Q Q Z W�� QL z 00 C11 z d�,h Z m ,�� = a Z Lu T-1 a to SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO. 10 O SHEET NO. 1.0 TYP @ 1 CORNERS D2 U.N.O. R &S EGRESS ('---- CC:,; FIBERGLAS SURROUNS TYP @ 2 STORY 1 _ ifl W.I.C. ; BEDROOM 4 P � 3 D2 8'-0" FLAT CLG.j I 8'-OCARPET CLG. " FLAT BEDROOM 3 I 8'-0" FLAT CLG. 4 H1 D2 fnl = �1 I� o 1 „ iv CARPET Q � q i — — 7 l — ROOF G.T. — — TIL — — �- _ _ 0N — w r _ o-t, 13'-0" i 11'-8" 6'-52" 2,�„ 4'-22" r9 I iv O G oo i I TYP @ 2 STORY 0 O Cr I J `� T 1„ „ I 1 S6 to 4068 B.F. I N w z - 4068 B.F. _4 r Wp z m - 2'-3" �'� SHOWER —�� J N sIM. -------- R&S FIBERGLA N m 2668 ------------- D2 W/ 5 STU ) S SURROUN N 4'-0" 10" r 6'-10 5'-4" 2-42" 2668 13'-72" 5' M o co 6 H1 (D2) " BEDROOM 2 O� ' 8 8'-0" FLAT CLG. w 24 LA CLG o I I „ r36' x.22 — I I ATTIC 1 ' CARPET q 8' 0' I co m I I pIt -1 X1 ao in — I O 1 LL: oo a 1 c TIE I I I j( �0 1 a� i I r ,r,_ I _ I T-812„ _ " 2'4- 2868 -J 6'-10' 5'-4,, 2'-6" 0° Ln I '- p� c� CON — I I -----J__J � N 16-8„ rn 4,-02-1„ 3,-7j„ OWNER'S 3R/.A. G. 16 6 SUITE LOFT I _ -- I Ofit D2 � 8 -0 FLAT CLG. 1 1 14 = _ CARPET I I 8'-0" FLAT CLG. CARPET D2 13 _ _ _ M¢ ROOF G.T. 1:H3 ttj— — — — - — 11 z "' I I -W O N I II `� 10 , ' TYP @ 2 STORY 1 2 4 5 6 7 8 I I= o '7 I l e TYP @ 2 STORY I I I I I I S6 J I I I I I I I I I J_ HEADER SCHEDULE MARK HEADER SIZE REMARKS H1 (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE H2 (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE H3 (2) - 2X10 #2 SYP W/ 1/2" FLITCH PLATE H4 (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE H5 (2) -1 3/4" X 11 1/4 LVL 2.0E Fb=2950 H6 (2) - 1 3/4" X 91/4" LVL 2.0E Fb=2950 H7 (2) - 1 3/4" X 16" LVL 2.0E Fb=2950 H8 (2) - 1 3/4" X 71/4" LVL 2.0E Fb=2950 (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required * VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED ** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS 140C EXTERIOR 2ND FLOOR BEARING WALL SCHEDULE HEIGHT STUD SPECIES SPACING SPF #2 8'-0" 2x4 SYP #2 16" O.C. SPF #2 9'-0" 2x4 SYP #2 16" O.C. SPF #2 >9'-0" 2x6 SYP #2 16" O.C. * IF WITHIN 4FT OF END ZONE, USE DOUBLE STUDS AT CORNERS * WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT ** SEE C/S6 WALL SCHEDULE WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20 X 26 18 J X 25 J S.H. 13 20X381 18JX37j S.H. 14 20 X 501 18 J X 50 S.H. 15 20X63 18JX62j S.H. 16 20X72 18JX71 j S.H. J 32 27114 X 26 26 X 25 } S.H. J 33 27 1/4 X 38 N/A S.H. J 34 27 j X 50 1 N/A S.H. J 33 N/A 26 x 37 S.H. j 34 N/A 26 x 50 S.H. J 35 27 1 X 63 26 X 621 /2 S.H. J36 27JX72 26X711/2 S.H. 22 37 j X 26 36 J X 25 1/2 S.H. 23 37 j X 38 j 36 j X 37 3/4 S.H. 24 37 j X 50 1 36 J X 50 S.H. 25 37 j X 63 36 j X 62 1/2 S.H. 26 37 j X 72 36 j X 71 112 S.H. DOUBLE 2 WIDE 75" TALL 73 J WIDE S.H. 32 54 X 26 52 J X 25 j S.H. 33 54 X 38 1 52 j X 37 j S.H. 34 54 X 50 1 52 j X 50 S.H. 35 54 X 63 52 } X 62 j S.H. 36 54 X 72 52 J X 71 j S.H. 39X59 40 X 59 NIA S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 1 3/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors, equipped with self -closing device. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shelf be protected as required by section R302.11, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is Iocated.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" ® +25.6 / -27.8 © +25.6 / -34.3 © +24.5 / -26.7 CD +24.5 / -31.9 �E +23.0 / -25.2 +23.0 / -28.9 GO SEE SN SHEET �H SEE SN SHEET 140 MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALL LEGEND �111111111111111� � - TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "B" 1ST FLOOR LIVING AREA 1093 2ND FLOOR LIVING AREA 1489 LIVING TOTAL 2582 GARAGE 427 FRONT ENTRY 35 TOTAL AREA 3044 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONIC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 1 R-11/R-13 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION I R-11/R-13 KRAFT FACED (GARAGE / LIVING) Z o Z Q CL V) C Q) cn -Ij W p �U — O W Lv I- E o _ m V) .2o m U W N M CD Cl) o —� in macQ Ooa = ai Ual, LLCD Q co))"M A 1 B D. N.C. B�D;C p( I� CS C'4 M R � � LL••z '3 S 9 b✓ M N ; Lr�u 4� W l LL- _`\�❑ UiP t i 4 i f I igF' To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z NO 0 1� M H � O Q V) °- �'- in LO Q U_ z0� U a 00 � Q z � cts Z J � W zz 0 z d f� Z�o U 2 w w ct �owz z Q �� U W F- N oZ cc:a `J } fz z 0 ofp Lr) L(_, o N UU 9� o� a�OZ 'P TYI� lC,�o� O U .2 m a N Z¢< za QV- Q$ R. Z N Wo, o 1�o� J Q z 9-0,6i Pa< <�Z O OD Z a U)z cc)0 ^ ..] 2 a z ,-I a to SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION N0. 10 SHEET NO. 1.1 SEE PLAN FOR LANDING DEPTH MIN. (3) 2x STUDS REQ'D @ END OF LANDING BELOW HDR. BEAM. STANDARD (3) 2x12 STRINGERS w/ SIMPSON A35/USP MP34 CLIP TO FLOOR SYSTEM OR LANDING FRAMING (2) 2x HDR. REQ'D @ END OF LANDING FOR STRINGERS TO CONNECT TO MIRROR 0 KITCHEN ISLAND PLY SHEATHING OVER LANDING ATTACHED PER GENERAL FLOOR CONSTRUCTION NOTES 2x8 #2 SYP JOISTS @ LANDING @ 16"O.C. w/ SIMPSON A35/USP MP34 OR LUS26 HANGER ON EA. SIDE MASONRY OR WOOD WALL, SEE PLAN 2x8 #2 SYP (P.T. IF MANSONRY WALL) CONT LEDGER w/ (3) 16d NAILS @ 16" O.C. MAX. TO EA. STUD. ((2) 1/4"X3 1/2" TITENS @ 16" O.C. MAX. FOR MASONRY WALL) GENERAL LANDING FRAMING INFO. SCALE: N.T.S. 9'-0" MAX LANDING LENGTH OWNER'S BATH r F O M O N 0 ih KITCHEN x-n-, 8'-51„ KITCHEN INTERIOR ELEVATIONS_ SCALE: 1 /2"=1'-0" STAIR CALCLITIONS: TOTAL RISE = 10'-0 3/4' PRE-ENG FLOOR JOIST W/ (2) (16) RISERS AT 7 9/16" 10" TREADS w/ 1" NOSING LAYERS OF 314" PLYWOOD Stairway construction and handrail to conform to the FBC 5th Edition (2014) FOR SOLID NAILING Residential section R311.7 Riser height: CONT. HANDRAIL The maximum riser height shall be 7Y4'. The greatest riser height within any flight of stairs shall not exceed the smallest by more than V. T 1x RISERS (TYP.) Tread depth. The minimum tread depth shall be 10". The greatest tread depth within any STANDARD (3) 2X12 flight of stairs shall not exceed the smallest by more than STRINGERS W/ SIMPSO14 A35 CLIP TO FLOOR Nosings. SYSTEM The radius of the nosing shall be no greater that 9/s'. Solid riser nosing shall not be less than %" but not more than 1%4'. The greatest nosing projection shall 2x8 #2 SYP JOISTS @ LANDING not exceed the smallest by more than %". Beveling of nosings shall not exceed 2x8 #2 SYP JOISTS @ LANDING @ 16" O.C. w/ SIMPSON 35 CLIP @ 16" O.C. w/ SIMPSON A35 OR LUS26 HANGER EA. SIDE SEE CLIP OR LUS26 HANGER TO PLAN FOR CLG. HT. Handrails, LEDGER Handrails shall be provided on at least one side of each continuous run of 2xl2 HDR. w/ (3) 2x STUDS AT treads or flight with four or more risers. Handrail height, measured vertically EA. END FOR BEARING a' PLYWOOD @ from the sloped plane adjoining the tread nosing, or finish surface of ramp LANDING `, slope, shall be not less than 34" and not more than 38". Handrails adjacent to a STANDARD (3) 2X12 wall shall have a space of not less than 1Y2"between the wall and the handrails. STRINGERS W/ SIMPSON A35 co CLIP TO HDR. Grip -size. 00 2x12 HDR. w/ (3) 2x STUDS AT Handrails with a circular cross section shall have an outside diameter of at EA. END FOR BEARING :,,, least 1 114" and not greater than 2" or provide equivalent graspavility in 1x TREADS (TYP.) .= compliance with FBC 5th Edition (2014) Residential Section R311.7.8.3. 2x8 LEDGER #2 SYP w/ CONT. (3) 16d NAILS TO STUD Guards. HANDRAIL @ 16" O.C. Nb� Guards shall be located along open -sided walking surfaces, including stairs, — — — — ramps and landings, that are located more than 30" and shall be not less than LO 36". Required guards shall not have openings from the walking surface to the — — — — required guard height which allow passage of a sphere 4" in diameter. Winders. Winder treads shall have a minimum tread depth of 6" at the narrow end and shall have a minimum tread depth of 10" at the intersections with the walkline j — — — — 7 F (12"from the nan-ower side). THRUST BLOCK SECURED TO R302.7 Under -Stair Protection. SLAB w/ 1/4"X3 1/2" TAPCONS Enclosed accessible space under a stairway shall be protected with''Y2" gyp. bd. @16"O.C. STAIR SECTION SCALE: 1 /2"=1'-0" U Z o Oz� t� z t.n(D 4) N (D(Un 4--J Lu U — w c ul E o ,^ = M v I O m f` U LU �, M C) M M E U � N 5- CO f Y LO O OV' Q m Q O RD N C B D C iL7 '}i .w �` .� fOr��•Y V s. OOn Z F W . Il,,, M C,- , • Q_r ac-ra �� Z d. UM WQ N � c.SS7 /1PPP3d:t,' To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD O Z N 0 (3) r. 0 i>—i M O Q V) 170 V) Q L- U Q , M IY U Q 00 a EU.J Z W �- J Oz z� Lu Z <a <¢ V,XW wQ ZVO U ZLu w �oWz Q OV�LLN Lumow° ro oLn W n >o < Z U �W (� CC ~ s � > N W O z Lu� o� ¢�O o V-4 J N eQ� X O U o �0�m� as d a �} T N I� Z<oa W Q J Lu< < Q 0 �o Z W J Ll1 .--I W �QoZ, o W Q z~0 0. Z <�Z *k � a 0 g = <z r, r-1 0- to SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO' 10 O SHEET NO. 2.0 8" ;o • FIN. TO HAVE TRADITIONAL 5" LOOK & SMOOTH FINISH • FOAM/ EPS MATERIAL IS ACCEPTED DECORATIVE CORBEL c6N71-1 /M C9 u w -IN 1/2 OF 1NDOW WIDITI 312.. DECORATIVE SHUTTER L 1" RAISED STUCCO BAND 2" RAISED STUCCO BAND to to SENTRY COLUMN DETAIL N t_ T.O.P. HDR HGT. — — — ------( I I I 2 I I I I 12 5 ------------------- J 12 50 = 5 2nd FIN. 0 T.O.M. -- HDR HGT. I I i 1" x 6" SMOOTH j TEXTURED SILL / BAND I 35 SH F.FL. -------------------------- 12 16" x 28" GABLE END VENT 12 !�_11� 5 1" x 4" SMOOTH TEXTURED TRIM / BAND u f ICI �I 1" x 12" SMOOTH TEXTURED 25 SH �—TRIM/BAND FRONT ELEVAT ION -B SCALE: 1 /4"=V-0" LEFT ELEVATION - B 1" x 8" SMOOTH TEXTURED HEAD/BAND ------- T.O.P. ------- HDR HGT. 2nd FIN. FLR. ------- T.O.M. F.FL. N ti N IN General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco at over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contractions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • Atwell and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 11150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion o the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. **CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. *If not enough vented soffit is provided due to fire protection, the contractor shall use the following approved vents: • LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. TMFormula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 9 = ear Ft of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT *'Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed)] 86.26 = Amount of O'Hagin Vents Needed Z o — o Z(09 z� Q I� Cn N Q)(U 4-- J w p .0 — OLu 0:� 07 � o o 0 � mr d) M ur — $ rn ce) Cl) 0 00 = W U Lu-m CO Y .x CL O Q rn Q o A ! B D NCBDC 5 6 " ��,��'�`• N `E4p ••u cc �0 •OM•� �NWa sit vO�tAf W ` �Q( of ,�, fl¢° e LL V S1 Ov�l I L o 81�iZOEI To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z N O N n F-•r t-' O >(j MO M Q °.- 0z.- a) -Ln I- C- , r i� V rn Q 00 Q E (� z J 0 W oZ �o W Z a 4� V J ¢ MIL Z O U ZC° o I- �o�z W f ., - J O(.J�u_N ° LLI __J N z o l n LLJ LU Z Z -a N p 3 8 j iv 0 O V Q Z J Q o ao0 h s" ' �a� 83 V ¢ O u— Z J ��¢a (� Q � aOw� � f O z z N ao z LLI L n 2:Q cwa � 8 Z o a O CO 00 Q z z~o tua.Iz z Cy _'LLJ¢ z � r-'I 0- cn SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 SHEET NO. 3.1 00 ;0 00 �leD 00 00 bo ti 12 5� T.O.P. HDR HGT. 12 �5 CJ CJ CJ 2nd FIN. -------------------------------------------------------------------------------------- -- FLR. CJ / WEEP 12 CJ / WEEP T.O.M. HDR HGT. ----- ---------- ---------- ROOF TO BE — --- ---- --- — CENTERED ON DOOR it 2 SH TEXTURED CEMENTICIOUS FINISH ON C.M.U. (TYP.) F.FL. T.O.P.-------- HDR HGT. 2nd FIN. _ FLR. T.O.M.-------- HDR HGT. F.FL. REAR ELEVATION - B RIGHT ELEVATION - B SCALE: 1 /4"=V-0" General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim, Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion o the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. **CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - (Values to be verified with Manufacturer Specifications) + RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN, OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA I SQ. FT. *If not enough vented soffit is provided due to fire protection, the contractor shall use the following approved vents: • LOMANCO DECK -AIR (Shingle Roof) - 9 SO. IN. OF NET FREE AREA / FT. '*Formula: (Sq. Ft Sofflt Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT "Formula: (Sq. FL Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed 0 Z o — o co Q z a--J w C) �U — O w C I— E o l%�i t•�- o 0 U a)m ► u O — 00 WId> N a M C0 T:aMN O o0 r U(D yt L- co Sao L" o � m L JC 0.) A B ' D. N,C,B •D ,C ,sa, w/ a %,� o v �•c �� v .n ? i o ri LA co �0 S S O' i�j //url 1111\0 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 z N O N n F-4 4-J (� M f O M ) ft3 Li) ato d Q iJ U InI CL .. M DC V ro ' q § fa z WJ kD w� z¢a ¢X Zu, O N zUO0 zwz¢ z Q W LLJ 8�-S m r o LU � Z o 4 U H fo N ~ o > — z z a U < /■L. J LLI >Q -O �-� N J�■ ••• Z°doa < a ¢o � O F E, C Z W N Eago Ln G Q LL1 Q Z Q j O98 ¢�z C] � CO Z a �i V)z J O IY] rn A _ ¢ z uJ ,--I a to SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION NO' 10 SHEET NO. 3.2 ELECTRICAL SPECIFICATION zooAlCENTE PANEL CENTER NOTES: 111, #15 copper to lights & outlets ELECTRICAL CONTRACTOR NEMA 1 #12 copper to 20 amp ckts 200HMP MUST VERIFY WITH THE 01 #10.2 to wH SPECIFICATIONS FOR THE TYPE #10-3 copper to Dryer OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR METER LOCATION PURPOSES. MAINT 200 amp /0 or 4/0 SER Alu 150amp GENERAL ELECTRICAL NOTES: Notes: unless otherwise noted, 1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible, 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. ELECTRICAL KEY I DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER W.P. WEATHERPROOF DUPLEX OUTLET G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET 177111 DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET $ WALL SWITCH 3 THREE-WAY SWITCH ?4 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE P.C. LIGHT FIXTURE WITH PULL CHAIN A. TRACK LIGHT FLOURESCENT LIGHT FIXTURE O EXHAUST FAN ;0+ EXHAUST FAN/LIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) CH CHIMES (OPTIONAL) 0 PUSHBUTTON SWITCH (OPTIONAL) SD SMOKE DETECTOR CM SMOKEICARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) ® TELEVISION (OPTIONAL) ®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. O THERMOSTAT ELECTRIC METER ELECTRIC PANEL DISCONNECT SWITCH SPEAKER (OPTIONAL) �7 ROUGH -IN FOR OPT. CEILING FAN v J c� CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR G J OPT. CEILING FAN (9D (1) PHONE LINE, (1) DATA PORT POWER CO. FEED INTERSYSTEM BONDING TERMINATION PER NEC 08, 250.94 4 Bare Cu Ground WITH CODE APPROVED CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC. Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. DEDICATED RECEPTACLE FOR MICROWAVE RANGE HOOD PER SPECS VERIFY METER LOCATION WITH MAIN FLOOR ELECTRICAL PLAN SCALE: %4"= V-0" UI to zo O z� N z Q CL z nV) C(aW C DlU 4--J w n — OLU Vi O o Mo U mr- 0, M LLI ♦— O all U C 0) M W a M O 20 T 0) cl) U L LL 0D 0 � Y Qe to O d Q 0 rn�o A , N-C f D,C r_ O N CID CID � N �r to t9 yo�o°' �_ C V ° ° Z W t,NZ M 0 t1. z J to L C A/ i� = LL O a U) LL LL. "i CCj7 N QW ' VQa�$ Q. W Z?yz iO t9yW064 g Ems? IL mm W aNaM 02-8 Jo O U 0 V El El To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N O a� n � �O >�Mo Q��L n. � Q LL ZF_ C>)- ,, M V fa < § E fa Z _j� LU d' 01 �o W� Z f a Z o°d Jo�.ao Z Q W 4 = 0 w Z J Q �22J LO g � U W N �W© -1 Q to Z Z y- H Qo � Z H O W g 4� Lf) w o ; N _ to 0 LL ; < Lu 'o u- ¢�OZ H z. —I mZ Uxo Ooa' O N <o Q <Qw� Z oQ_�oN a(DZ J 2:Q 0Zo iLia O � Q Z Z WLu IZ < ce az �O m O t,--I` 4Z J = ¢ z uj a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO. 10 O SHEET NO. 4.0 ELECTRICAL SPECIFICATION 200A INDOOR PANEL CENTER NOTES: #15 copper to lights & outlets ELECTRICAL CONTRACTOR NEMA 1 #12 copper to 20 amp Me 200 AMP MUST VERIFY WITH THE 10 #10-2 copper to WH SPECIFICATIONS FOR THE TYPE 0 #10-3 copper to Dryer OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR METER LOCATION PURPOSES. MAIN 200 amp 2/0 or 4/0 SER Alu 150 amp GENERAL ELECTRICAL NOTES: Notes: unless otherwise noted, 1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314,1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in comer counters. ELECTRICAL KEY 0 DUPLEX CONVENIENCE OUTLET PEPP DUPLEX OUTLET ABOVE COUNTER W.P. WEATHERPROOF DUPLEX OUTLET GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET FW SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH �3 THREE-WAY SWITCH 6. 24 FOUR-WAY SWITCH jR RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE n RECESSED LIGHT FIXTURE �J P.C. LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE O EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION ®D ELECTRIC DOOR OPERATOR (OPTIONAL) CH CHIMES (OPTIONAL) ED PUSHBUTTON SWITCH (OPTIONAL) SD SMOKE DETECTOR CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) © TELEVISION (OPTIONAL) ® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. O THERMOSTAT ]M ELECTRIC METER _Ila ELECTRIC PANEL _mil DISCONNECT SWITCH SPEAKER (OPTIONAL) �7 ROUGH -IN FOR OPT. CEILING FAN � J c/> CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR G J OPT, CEILING FAN (1) PHONE LINE, (1) DATA PORT POWER CO. INTERSYSTEM BONDING TERMINATION PER NEC 08, 250.94 Bare Cu Ground CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC. Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. RECEPT. FC- - UPPER ELECTRICAL PLAN SCALE: %4"=1'-0" U( u7 zo CD Q Z V) U W [n i--J LU O w Lv I— E 0 � (AO U LU (D M Cr (0 M I-- E —coi N O M 04 Ooo ai - E 00 U D LvY 0) ao rn O-T Q 0) Q O B ®® �a N co cc fwV ooo°' L-j co N O o ZWyM-Z 5 U_ � L.L a Wa"'NM,� &.-P LJJ a w _ �ia'a_� OZO a �z ENO ', O m C1 V r` LLtw ZN0)a-fl a d� W 04 0 � of To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O C:) Z 0 a) r-, M H � O M Q V) M Lr) °- U 'L I.f) fl. ^ F- U oC V CL � Q E Z WJ C) d' �Z 0 3� �q znQ z� Z E� �aoa < �z800 CL Z w �0Wz U Q J W J Q 8a$ N U cLLJc FWo oN zz r r; Lf) f— U `Z Z 5 z -0 N LU an3 Lr) Lij > N g o UU z (n O ULu 'o a LL < 0 LQl U m ¢ OQO_°d I� WZ�¢ Q V ~ 2:O Z N a W In �QQZ J t- 4 LUrn 2:Q o z g �¢� O 00 Z Z aUJ az 1V ZZ Jo 0 LUa z T--1 0- cn SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO' r1 ■ O SH EET NO. 4.1 VENTED SOFFIT 42 SQ. FT. RIDGE VENTED SOFFIT 40 SQ. FT. Lull 11, W O I O I (7) C6 L 9'-O' RIDGE VENT 140 N RIDGE .. 4'-O' ROOF VENT 5:12 ;;. W ` DPE L O J N T ' \O :12SLOPE 11110 5:12 SLOP •.• TaN W ... I .. LO 10 ZONE-2 ATTIC SPACE ..1.7 4'_O' ROOF VENT 1533 SQ. FT. 71. era s,<• ;' ::� W o • 1• N T COND. VENTED SOFFIT 40 SQ. FT. � 1 12 ........... •.. RIDGE .•. 2 ATTIC VENTILATION CALCULATIONS - B ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED 1/150 Rule 1/300 Rule Ridge Off -Ridge (No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. Req.) (Ft.) Total Ventilation ATTIC Provided SPACE SQ. FT. Total SQ. SQ. FT. SQ. IN. of by Upper SQ. IN. of ventilation of vented IN. of of vented ventilation to be provided SO. IN. of SQ. IN. of Ventilators (See Elev) required soffit ventilation upper Ventilation Ventilation needed required needed ventilators Main 0.000000 0.000000 Floor 0 0 0 0 0 0 0.0 0.0 0.0 (Zone 1) Upper 9 2.000000 Floor 1533 1472 210 736 53 368 411.0 276.0 (Zone 2) 135.0 **NOTE** GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS REQUIRED BY FBC 5th ED. RESIDENTIAL. VENTED SOFFIT LEGEND IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. VENTED SOFFIT VENTED SOFFIT 19 SQ. FT. ZONE-1 ATTIC SPACE 35 SQ. FT. VENTED SOFFIT 29 SQ. FT. ROOF PLAN SCALE: %4"=1'-0" General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over mason ry,concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1 /150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion o the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by save or cornice vents. **CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ, IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. *If not enough vented soffit is provided due to fire protection, the contractor shall use the following approved vents: • LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. **Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86,25 SQ. IN. OF NET FREE AREA / VENT **Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed Z o —0 Z co Z e( J 0— Z U (V W cs) 4--J Lu •U — O LU V) ~ E Lo M R5 >� YZ0 t✓ O m M LU s y RigI— E N C W M m -o ca Q U O ai p LL00 Qo OC:)LO v rn4o BDtea. N�C •B�D.`C g .I 'IflO qy N co 0 0�^ ®0Z �a � L � cn— q" w Z '.. LZ X "s W N Q NjISI@II17� q10��f� i U V O ❑❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z� CO ) 1. M O M z 0 H U_ U fl.00 Q E � fD Z W Jo� 9.0 d' o Z o W� z a O0 H U 0 2 W V z owz (Y X J 0 m z O 8 , Z 0 4 V A L z z O N V)3: Cz G N 8 O > N ¢ a a V (n J Q_ `1 o s LL O QRo Y Wood y� N 0 2 m 2 o�oa Z gyp.. nJ. Z J Q ~ ~ d Z17,14 N o,00 4�oz J r--1 LU Q o z o �¢ O Im Q z Z <LLIz aU) LU a z O J = SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO' 10 O SHEET NO. 5.0 M-0" 6'4' TYP @ 2 STORY J S6 5'-4" H.B. I 4-4- 3'-0" ■ ■ ■ ■ ■ ■ ■ ■ c 12 STORY CC (2) #5 REBAR S3 I VERTICALS w/ in FILLED CELL o I I " .rr _h � CM N II s 0'-0" o 11 L Jil 3 ^ M Nr��llz J I�UJain r-----------i (4 S3 I co ■;I I II I �—CJ — I Ir — — —_ — — — --_� _ I I CJ ( Y 4'41 STEPS AS _ _j -- ------ �� — 3 1/2 SLR : KITCHE SLAND I ,-Mn` ((1 I I I CHASE �J I REQUIRED PER LOW WALLS TO FIELD CONDITIONS I ( I : ISLAND I I ■• I � I I 1 3-1/2" MIN 3000 PSI CONC. PROVIDE 1 %" SLAB FOR HERNANDO I I I L ( RECESS FOR COUNTY ONLY 0 o S3 SGD. REFER TO 3-1/2" MIN 2500 PSI CONC I `" I I MASON'S SLOPE SLAB OVER 6 MIL I 2 STORY I -31l2" � FOR WIDTH VISQUEEN VAPOR I I BUILDER TO PROVIDE ' BARRIER _ ` APPLIANCE PROTECTION CC (2) #5 REBAR �� L I �� WHEN REQUIRED PER FBC S3 VERTICALS w/ in (2) #5'S iv 1 FILLED CELL A_rr , TYP @2STORY J L---------- — ------ •■ S6 i PROVIDE %" x 9" 1 -3 1/2" 2'-6" x 2'-6" x 1'-0" RECESS FOR FRT. DOOR SLOPE W/ (3) #5'S E.W. ■ : 0'-0" TOP OF CONC./ PAVER TO BE 4" L o BELOW FIN. FLR. S3 (2) #5'S M I { I I STUB1-9_0....... .. — — ■' LOOK " I 1 I I FOR A/C o N • G — T 71� CJ f CJ 2'4" x 2'-6" x 1' 0" W/ (3) #5'S E.W. o N 0 10 _ _ I 5'-416"L } INDICATES FILLED CELL w/ 3000 I PSI CONC. GROUT FROM FT. TO TYP @ 2 STORY I ::: ; ; ::: BEAM W/(1)#5REBAR VERT ( _ •1-1 ,1 ABOVE SLAB TYP @ALL PLACES N ' I I • : I SHOWN HOOKED FTG. DOWELS 5" M� E SLAB _ �' i .. EMBED W/ 25" EXT. ABOVI •,I���� (°� "GRADE ZN ' `� HVAC CHASE i�7 ■ • _ BASED ON I L — — 1 0'-0" '> J LOCATION � _j ■ ■ :. ■ ....... . ... ■ ■ ■ ■.■ H.B.+ TYP @2 J STORY S6 V-0" 4'-0" 54. 2'-2$•, . 2'-15" A FOUNDATION PLAN SCALE: %4"=1'-0" NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "E" OF THE FBC 5th EDITION (2014) BUILDING IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING W.W.M. PLACED IN 1/8" SAWCUT x 1/4 SLAB UPPER 1/3 OF SLAB THICKNESS WHERE OR FIBERMESH SHOWN ON REINF. SEE PLAN. FOUNDATION PLAN _V W W W d 7C" CONTROL JOINT DETAIL SCALE: 11/2"=1'-0" #5 CONT REINF. SEE _•' "�, FND. FOR QUANTITY �� ��'• �'' #5 X 25" X 25" CORNER ' ' �' BAR ONE FOR EA. HORIZ. REBAR, TYP. U.N.O. • • '�_ **Alternate: ; ; ,: ,'; The reint bars shall be cont. around comer by cold bending the bar w/ min. bar lap of 25". TYP. CORNER BAR DTL. SCALE: 1 1/2"=V-0" � r Z o Z Q U) z cV) C� W cn +_j w �U _ 0 LU Of E 0 (A V) 0 0 co w I--- o 8 Cn co 2 'O coca N 02 4i ID U L LL co 7 N Y 0 O Q Qrn rnQo s m W. N•C.B -D•C TF" I r o iYV N ", Z � L LL oe. W VA U°� ® o % WE itt•.�'���a4 �In;� o �.I't•���t egltlrillliRl�^ ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O ON Z 0 Ili jr) 0 Q "v LP) °- in s= QL_ LLLL CL M 0� V Q OC) Q J � W d' oz V) � W za ga z zgo U z¢ o /J IlZ y�WZ RC�-J Z 0 6YLu LL N Uw Wo oLO zp a� ilk g -0 z V3 o i > N O L 0 '^ v` 0 z 0 Ja �w w o ¢�Q-0Q ` o .J XOLu N g U4 � ct � �Za � a � �a Z N Lr);W'z o J IJ.I o w o PQa O l� Q Q Z "~o k 00 Z ZUj aZ 0 1 4 J2 z uj 1� a Ln SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION N0. 10 O SHEET NO. 6.0 UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. O CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 -10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA16 1615 1585 10 -10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8- 8d RT3 610 525 8 - 8d X 1 1/2" E META20 1450 7 -10d x 1 1/2" HTA20-18 1400 1400 10 -10d X 1 1/2" F HHETA20 2235 10 -10d x 1 1/2" G H10A 1340 1015 18 -10d x 1 1/2" RT16A 1380 1160 9-10d X 1 1/2% 8-10d H HTT4 3610 3105 5/8"ANCH.118 1061-1/2 HTT4 2715 50ANCH.1(20)10dx1-1/2 J HTTS 4350 3740 5/8"ANCH.! 26 10dx1-1/2" HTT5 3225 50ANCH.I(28)10dxl-1/2 K HD B * 1 3130 3050 5/8" DIA. BOLTS TDX2-TZ 2345 - 2 - 518" DIA. BOLTS L HD B * 4505 785 5/8" ANCH. 3/4" STUD BOLTS TDX6 5320 - 2 - 7/8" DIA. BOLTS M HD76 * 6645 5650 7/8" ANCH. 314" STUD BOLTS TDX10 7845 - 4 - 7/8" DIA. BOLTS N LUS26 116511070 ** 1005/915 ** 8 -10d x 3" JUS26 1115/1060** - 8 -10d P —HUS26 1550/3335 ** 1335/2820 ** 20 -16d x 3 1/2" HUS26 1925/3295 - (20)16d x 3-1/2" Q HUS28 2000/4220 ** 1720/3125 ** 30 - 16d x 3 1/2" HUS28 2570/4345 - 30d -16d x 3-1/2" R MTS12 1000 860 14 -10d x 1 1/2" MTW12 1 1195 1005 14-10d x 1-1f2" S MTS16 1000 860 14 -10d x 1 1/2" MTW16 1195 1005 14-10d x 1-1/2" T MTS20 1000 860 14 -10d x 1 1/2" MTW20 1195 1005 1410d x 1-1f2" U MGT/MUGT 3140 3140 22 -10d X 1 5/8" ATR W/ 5" EMBED W/ SIMPSON "SET' EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4" x 2-1/4" TITENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4" x 3" WEDGE BOLTS HTS 20 1450 1245 24-10d X 1 1/2" HTW20 1530 1285 24-1Od X 1 1/2" SP1 585 535 j 10 - 10d I SPT22 685 8 - 10d SP2 1065 605 112-10d SPT24 1030 12-10d CP2 1 645 555 1 12-1Old X 1 1/2'. * MINIMUM 3" MEMBER ** REACTIONS ARE FOR ROOF LOADS ONLY *** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS - ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL 2-0-0 MAXIUM SPACING ON VERTICALS OF I TRUSS ++) (B) B) (A) (* 1 OR 2 PLY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") *FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (-). (B INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS OR J�/ 2 Pl�yy CARRIER—J INTERSECTIONS. SPLICING 2 x CONT LEDGER TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE V-0" ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. �--� --- — STRUCTURAL 2x STUDS SEE PLAN X ---- JFT2 SHEATHING (SEE TB13 FOR INFO x --- — IN— LL. FOR NAILING tNFO. ) PLYWOOD FG3 _ _ _ _ _ \, 2x6 CONT. W/ (2)-12d NAILS @ EA. TRUSS FT5 I I I I I I I I 2x CONT. W/ (2)-12d CANTILEVER COND. COND. I I I I I I I I NAILS @ EA. TRUS FLOOR TRUSS I I I I 1 I I 1 2x4 CONT. RIBBON W/ (4) 16d NAILS EA. TRUSS�', 2 TYP @ 2 STORY A 2x BLOCKING W/(2) 12d D2 S6 NAILS @ EA. END SEE PLAN TRUSS BRG. a ONNECTOR AT EACH TRUSS, 8d NAILS @ 24" O.C. SEE PLAN TO BLOCKING LINTEL SEE PLAN STRUCTURAL SHEATHING rFCO3 CANT. FLOOR TRUSS CONN. SCALE: 3/4" = V-9' MAIN FRAMING PLAN 0 0!� z o �q Z Q a V7 (D sis ID(a 4'—J Lu U — O w F- E V) h- 0 O co U (6 o m a) M f-- E -r; all m 'a N Ooo = ai a) U� - IL m -5 - 00 Q moo C It o rn m A 1 N C BDC477 wa ® zt ) N� o o o P• (5, J Z•, LL o .IL N , s LI J a L` - 9 LL'` 8 Ytp V ¢ g �Y=t� <A u> 0) M fnk,,c LLE4` ID W �-N4 �jJ'?g5e�ltlp� I" ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. c Z r4 O 0) N Q V) rozro Ln (Al�i N ) Ln Q � L ,-7 Z i- >- . M (10,-q �V C00 Q z�� WJ 0 d- 0 W� z a a� Z zoo Q Zew —� �oWZ Lu g 0 8 Z 10w@ oN Zo 01: �z 5� Z LL O ~ O oN > N O to J ILLOZ o� O r Q y -1 y a'. O X U.0 U og, m a N CC ZL42 w a Z 2 Z z (V N Ln � J LL 1 a la- o �¢ oUj lfl Q z z «0 iV z a z o I� Q :5 = a z SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION NO' 10 O SHEET NO. 7.0 N\ 3Y UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. O CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 -10d x 1 1/2" HTA20 1615 1585 10 -10d x 1 1/2" B HETA16 1810 9 -10d x 1 1/2" HTA16 1615 1585 10 -10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8-8d RT3 610 525 8 - 8d X 1 1/2" E META20 1450 7 -10d x 1 1/2" HTA20-18 1400 1400 10 - 10d X 1 1/2" F HHETA20 2235 10 -10d x 1 1/2" G H10A 1340 1015 18 -1Od x 1 1/2" RT16A 1380 1160 9-1Od X 1 1/2"& 8-10d H HTT4 3610 3105 SW ANCH. / 18 10dxl-1/2 HTT4 2715 5l8" ANCH. /(20) 10dxl-1/2 J HTT5 4350 3740 5/8"ANCH.1261061-1/2" HTT5 3225 5l8"ANCH./(28)10dx1-1/2 K HD B * 3130 3050 5/8" DIA. BOLTS TDX2-TZ 2345 — 12 - 5/8" DIA. BOLTS L HD5B * 4505 378 5/8" ANCH. 3/4" STUD BOLTS TDX6 5320 — 2 - 7/8" DIA. BOLTS M HD7B * 6645 5650 7/8" ANCH. 3/4" STUD BOLTS TDX10 7845 — 4 - 7/8" DIA. BOLTS N LUS26 1165/1070 ** 1005/915 ** 8 -10d x 3" JUS26 1115/1060** — 8 -10d P HUS26 1550/3335 ** 1335/2820 ** 20 - 16d x 31/2" HUS26 1925/3295 — (20)16d x 3-1/2" Q HUS28 2000/4220 ** 1720/3125 ** 30 - 16d x 3 1/2" HUS28 2570/4345 — 30d -16d x 3-1/2" R MTS12 1000 860 14 -10d x 1 1/2" MTW12 1195 1005 14-10d x 1-1/2" S MTS16 1000 860 14 - 1Od x 1 1/2" MTW16 1195 1005 14-10d x 1-1/2" T MTS20 1000 860 14 - 10d x 1 1/2" MTW20 1195 1005 14-10d x 1-1/2" U MGT/MUGT 3140 3140 22 - 10d X 1 5/8" ATR W/ 5" EMBED W/ SIMPSON "SET" EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4" x 2-1/4" TITENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4" x 3" WEDGE BOLTS °X^ HTS 20 1450 1245 24-1Od X 1 1/2" HTW20 1530 1285 24-10d X 1 1/2" SP1 585 535 10 -10d SPT22 685 8 -10d SP2 1065 605 12-10d SPT24 1030 12-10d H P2 1 45 555 12-1Od X 1 1/2" * MINIMUM 3" MEMBER ** REACTIONS ARE FOR ROOF LOADS ONLY *** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS — ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS ++) (B) s) (A) (+ 1 OR 2 PLY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+J- 6") *FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). (B INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN NAILS, FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS "�O �y q�R�ER CNT LEDGER _�A) INTERSECTIONS. SPLICING TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE V-0" ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. ROOF FRAMING PLAN SCALE: %4"=1'-0" zo CO tij z� Q J IZ v, z Ln 0 W C (DM 4--J w 0 U — O W L,. �- E 0 un 0 0 U LU WM C" co F— E N a M O o 0 UUUU = ai = E ao Uaa)) Lv-e 0 rnn.o Ov Q u7 rnQ o A l B D® N C• B D C .�x�E�t 49i t aa�ai'4�19, p<n coLj U— . N 0Wcui � C1 Z :, C - .. = E,o ¢ 'c, y a C N !i `i Z f6 E rn .do � (L To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N O v M O j Q C/) "CO Ln °- V) .L Lfi Q LL 0C U C. 00 a E ,.., z cp WJ C:) 01 W0 za �F z W¢�a. O z 8,0 0 w� owz C 2 W 0 Qp U N W FzOO _Z (1 � rZ z i; rye• ¢ 2:z Z z O -0I A \ LL L- q 4 F 0 G ^L- Q)` O o / O J Q U— �\ LU O 0 O 1 J O X O U z od N LLI z¢ ¢ $oho z N WJ L0 L ,1 <ha ¢ r-I LLJ Q w .iC C) 00 Q z ¢_o of zl0 N avi z O ^ g = ul ¢Lu SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 SHEET NO. 7.1 GENERAL INSTALLATION NOTES 1, Provide full mortar head and bed joints. 2. Shore filled lintels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate vertical cell reinforcing and grouting. 5, Ali lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and longer with a nominal height of 8" meet or exceed U180. 6, Bottom field added rebar to be located at the bottom of the lintel cavity. 7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. g. Cast -in -place concrete may be provided in composite lintel in lieu of concrete masonry units. 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. 11. The exterior surface of lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with verttcal (gravity and uplift) and horizontal (lateral) loads shoud be checked for combine loading with the following equation: Applied vertical load + Applied horizontal load . 0 Safe vertical load Safe horizontal load — GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY MIMS MA win" a 81744 1B/1T8F401B/1T 8RF400B/1T 8F321B/1T 110) t j M IN MMIM TYPE DESIGNATION #SREBAR MIN. ATTOP (1) REca'D ALTERNATE POWERS = FILLED WITH GROUT /USUNFILLED R =RECESSED CLEAR EAR STEEL LINTEL ° ' QTY. OF #5 a ° REBAR @ BOTTOM ° OF LINTEL CAVITY z ° ° .M.U. T #5 REBAR AT TOP — - CJ w a ° , MIN. (1) REQ'D ° a 1-1/2" CLEAR 8F16— B/1T U Q Q Z ° " ° a 4 ° � `oy � z D p ° GROUT L r n J Q tNOMINAL. QUANTITY OF ° 5 REBAR AT F y Z w Q C.M.U. WIDTH #5 REBAR AT ° O BOTTOM OF o rn - F 4 - ed TOP LINTEL CAVITY o LU m NOMINAL -°-BOTTOM o ,Ux, d o � " HEIGHT REINFORCING ¢ ¢ C7 7-5/8"ACTUAL PROVIDED IN z p w m D J� D z 8" NOMINAL W DTH LINTEL C! i 5 REBAR AT BOTTON a Qo <o AS INDICATED (VARIES) co iB 4 16 GAUGE POWERS MATERIALS c precast ntels = 3500 psi. STEEL BOXED LINTEL 2. fc prestressed lintels = 6000 psi. 3. grouted per ASTM Cgat a d3"to psi slump. 4. maximum 3/8" aggregate and 8" to 11"slump. POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF NOTED ON LINTEL PLAN 5. Concrete masonry units (CMU) per ASTM C90 w/ minimum net area compressive strength =1900 psi, 6. Reber per ASTM A615 Grade 60. i. Refer to manufacturers specifications for installation. Prestressing strand per ASTM A416 grade 2. Contractor to provide proper protection of lintel to prevent rusting. 7. 270 low relaxation. Refer to manufacturer's specifications. 7/32 wire per ASTM A510. 3. If lintel is scratched or damaged refer to Powers Steel for repair. 8. Mortar per ASTM C270 type M or S. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel plan/details for bottom steel required. 5. A bonding agent must be applied to the Steel Box lintels prior to LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS applying the cementitiuos coating. See contractor specifications APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) 2x8 #2 SYP STUDS @ 8" O.C. W/ (2) USP MSTAM36 STRAPS EACH STUD ((1) STRAPS EACH SIDE) CENTERED W/ (13) 10d NAILS & (8) %4' TITENS OR (2) 2x8 #2 SYP STUDS @ 16" O.C. W/ (4) USP MSTAM36 STRAPS ((2) STRAPS EACH SIDE) 2x8 #2 SYP P.T. BASE PLATE W/ Y2" EPDXY ANCHOR OR %" J BOLT W/ MIN. 7" EMBEDMENT @ 32" O.C. & 6" FROM EACH END STRUCTURAL SHEATHING ATTACHED PER NAILING SCHEDULE doL SEE PLAN '-F T/VVALL 8" KNOCKOUT COURSE W/ (1) #5 CONT. SEE PLAN FOR FILLED CELL SPACING 1 WALL SPLICE DETAIL 8 SCALE: 1" = 1'-a" O 5'-8" LL LINTEL PLANT SCALE: Y4"=1'-0" t2 Z o Z Q Z W v� W 0 LU I— E V) C rr^^ ZD o OM V U m N co W t_o 0)m ooN U _ CD U t LL. 0000 co cu I Calf< -le Lo 0-0 0 Q O AB 1 N C D C C - / � p N cca Y �1� N 40 _ ,ia CO M°�,`O L. �j LL dR Lua IN v .@? ° 0xx ' ♦��;;, El To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z 0 O ►-, M MLn •L a � U_ �- n U CL00 � Q u z� W J�~ 0z �0 3� w� Z 4 � Q Q r 1 Z80 z Z Q p w Z J J 8 WK u_N m Z O� Z Z 8 Lr) g z z O -v N g S o N > N U CL W J W os J 0 UKp�•-� oQoa rN 1 ` J zu40 W J Z Q Q ~�Lu X° �a-o Z z W N ul w0z —1 rl LU LLl ¢ LL 5 Q Y a O 110 ¢ a z a F- ¢:�z 00 N Z a� U) Z m 2 ¢LU LU ,—I d to SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION N0. 10 SHEET NO. 8.0 NOTE: BORATE APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE (CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICAL THAT ARE CORROSIVE TO STEE L. EL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-0, CBA-A, OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS RE: FRC R308.4 R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY 11 AS INDICATED IN TABLE R308.3 EXCEPTIONS: 1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES, 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS, GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7, GLAZING W AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR. 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7. 3. GLAZING IN SECTION R308.4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING, 4. GLAZING IN SECTION R 308.4, ITEM 6, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION OR WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 7. 5. GLAZING IN SECTION R308.4, ITEMS 7 AND 10, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES f 2 INCHES (914 t MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 Ys INCHES (38 MM) IN HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL [WITHIN 45 DEGREES (0,79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR. 7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308.2. 8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 9. SAFETY GLAZING IN SECTION R308.4, ITEMS 10 AND 11 IS NOT REQUIRED WHERE: 9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF SECTION 1012 AND 1607.7 OF THE FLORIDA BUILDING CODE, BUILDING; AND 9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. 1. SPECIFICATIONS 1. 1. CONSTRUCTION: 1.1. 1. ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1. 1.2. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1-11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1. 1. 3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.1.5. FLORIDA RESIDENTIAL CODE (FRC), FLORIDA BUILDING CODE (FBC) 5th ad. (2014) 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC) 13TH EDITION. 1.1.7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TR11-02. 1.2. DESIGN: 1.2.1, ACI 301-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-11, ASCE 5ffMS 402-11 & ACI 530.1-11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1.2.6. FLORIDA BUILDING CODE (FBC) 5th ad. (2014) AND FLORIDA BUILDING CODE 5th ad. RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS: 1.3.1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 1.3. 2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA. REG. PE. AND SHALL DE : DRAWINGS AND CALCULATIONS, INCLUDE: U LATIONS REACTIONS AND BEARING POINTS BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS: 2.1.1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 1.2. 2 UNIT WEIGHT OF REINFORCED CONCRETE: 150 PCF 2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: 55 PSF 2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2.1.7. BALCONIES & DECKS: 15 PSF 2.1.8. TILE ROOF TOP CHORD : 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOP CHORD : 7 PSF BOTTOM CHORD: 10 PSF 2. 1. 10. FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1. SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2. GARAGE LOADS : 40 PSF 2.2.3. PARTITIONED ROOMS: 40 PSF 2,2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS: 40 PSF 2. 2.6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2.8. ROOF TRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE) : 10 PSF (NON -CONCURRENT) BOTTOM CHORD (ATTIC W/ LIMITED STORAGE) : 20 PSF 2.3. RAILING LOADS: 2.3.1. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SQ. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3.1., 2.3.2 & 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FBC 5th ad. (2014), AND CONDUCTED BASED ON A 140 MPH 3 SECOND GUST, EXPOSURE "C", IMPORTANCE FACTOR 1" =1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS -10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE 7-10 2.5. DEFLECTIONS: 2.6.1. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240 TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1. LOAD FACTOR DESIGN: 3.1.1. THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2. SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DL + FLOOR LL + ROOF LL TOTAL DL + FLOOR LL + WL TOTAL DL + WL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. 3.4, DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS. 4- MATERIALS 4.1. REINFORCING STEEL: 4.1.1. REINFORCING STEEL SHALL BE ASTM A615 / A185M-04A MIN. GRADE 40, fy = 40 Ksi 4.1.2. LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4.1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4.1.5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4.1.6. DESIGN COVER REQUIREMENTS: C-I-P CONCRETE FORMED AGAINST EARTH: 3" C-I-P CONCRETE EXPOSED TO EXTERIOR: 2„ C-1-P CONCRETE NOT EXPOSED: 1 y„ GROUT FILLED MASONRY: 1 4.1.7. WELDED WIRE FABRIC (WWF): ASTM A-185 / A 185M-07 4. 1. 8, DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-11 (STRUCTURAL CONCRETE) ACI 530-11 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1. CONCRETE TYPE MIN. 28 DAY DESIGN (fc) MODULES OF ELASTICITY DESIGN (E) C4-P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-I-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ksi C-I-P GROUT 3,000 Psi 3,122 Ksi 4.2.2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS) : 31/2" MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB, FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.2. 7. CONCRETE PLACEMENT PRACTICES SHALL BE IN ACCORDANCE W/ ALL ACI- MCP 2011 STANDARDS. 4.3. CONCRETE MASONRY: 4.3.1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-0601, TYPE 11 NON -MOISTURE CONTROLLED. 4.3.3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL STEM WALLS. 4.14. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm =1,500 PSI MINIMUM. 4.3. 5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.3.6. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. 4.4. STRUCTURAL LUMBER: 4.4. 1.1. INTERIOR LOAD BEARING WALLS SPF #2, fb =1,312 PSI, E =1,400 KSI ALL EXTERIOR FRAMING SPF #2, fb =1,312 PSI, E =1,400 KSI 4.4.1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4.4. 2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15/32" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. 4 4.3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH S SUB FLOORING D A G AN SHEAR WALLS SHALL BE APA RATED SHEATHING U.N.O. E G EXP 1 U 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES. 4.4.5, ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4.6. WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSI/TPI 1-2007, BCSI 4.4.8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 718" STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK 4.4.10. INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R706.6.1 4.5. FASTENERS AND TIE DOWNS: 4.5.1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTM A36/36M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTM A307 4.5. 2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33KsiWITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. 4.5.3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0.131",10d = 0.148",12d = 0.148",16d = 0.162". 4.5.4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION. 4.5.5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4.5.6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4.5.7. CONCRETE EMBEDDED 'J' BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. 4.5.8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.6. MICRO -LAM LUMBER: 4.6.1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E = 2,000,000 PSI Fb = 2,950 PSI Ft = 1,850 PSI Fc = 500 PSI (PERPENDICULAR) Fc = 2,700 (PARALLEL) 4.7. STEEL: Fv = 285 PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEEL ERECTOR. 4.7.2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4.7.3. STRUCTURAL STEEL: ASTM A36/36M 05. 4.7.4. STEEL TUBING: ASTM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3/16", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL: ELEMENTS ARE IN PLACE. 4.8.1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF 4.8.2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FBC 5th ad. (2014), RESIDENTIAL SECTION R318. 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02E01 TERMITE PROTECTION - CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate / Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1. FRC R318.1- "A permanent siggn which identifies the termite treatment provider for and need re -inspection a, treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel" 2. Condensate and roof downspouts shall discharge at least V-0" away from the building side walls. 3. Irrigation/sprinkler systems including all risers and heal installed hin spray shall not be w 1'-0" of the building side wall. 4. FRC R318.7- To provide for inspection for termite infestation, between final wall covering and earth grade shall not be less than 6 inches. Exception: Paint or decorative cementitious finish less than 5/8" thick adhered directly to the foundation wall. 5. FRC R318.1.1 - Initial treatment shall be done after all excavation and backfill is complete. 6. FRC R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FRC R318.1.3 - Boxed areas in concrete floors for subsequent installation of traps etc., shall be made with permanent metal or plastic forms. Permanent forms must be of a size and depth that will eliminate the disturbance of soil after the initial treatment. 8. FRC R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilution. If rainfall occurs before vapor retarder placement, retreatment is required. 9. FRC R318.1.5 - C n rete overpour nd mortar along the foundation perimeter must be removed �ia ore exterior sol, treatment. 10. FRC R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0" of the structure sidewalls. 11. FRC R318.1.6 - An exterior vertical chemical barrier must be installed after construction is complete, Including landscaping and irrigation. Any soil disturbed after the vertical barrier is applied, shall be retreated, 12. FRC R318.1 - All buildings are required to have pre -construction treatment. 13. FRC R318.1 - A certificate of compliance must be issued to the building department by a licensed pest control company before a certificate of occupancy will be issued. The certificate of compliance shall state: 'The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FRC R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-0" of the building. This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. WORST CASE DESIGN PRESSURE TABLE BUILDING DATA WIND SPEED (ULTIMATE) 140 MPH WIND SPEED (ALLOWABLE) 108 MPH WIND EXPOSURE o "C" (FRC R301) INTERNAL PRESSURE COEFFICIENT= 0.18 ENCLOSED BLDG) BUILDING CATEGORY = II DESIGN WIND PRESSURE: (COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) # END ZONE IS ONLY WITHIN 5'-0" OF ALL EXTERIOR BUILDING CORNERS WINDOWS AND DOORS 140 MPH + 29.7 PSF / -39.6 PSF (END) U.N.O. CONSTRUCTION + 29.7 PSF / -32.2 PSF (INTERIOR) U.N.O. GARAGE DOORS (V =140 MPH) TYPE: 5B SINGLE 9x7 +26.3 PSF / -29.8 PSF DOUBLE 16x7 +25.2 PSF / -28.1 PSF NOTE: THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES. NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1 4" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1 8" DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBAORD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW / NAIL DISTANCEFROM EDGE SHALL BE 3/". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. zo zC)O Z O J z Ln U' W cn J w �U - 0 tuJ F- E IV) F o O M m o U LU , M a tT Cl) Cl) �- E - c0i alla) m 0 0 0 _ Ulao =FLco �Co Y <C o� Qo Lo O V 0) AI B D® NCB -D-C / /or e L A`�1���u• 0 10 �F All11� 0 o� ffnn • .1` f�, Cam- o cof Z mgo,N'h '�r �F w u N ,n , N (,. a La LL CLO .2 04 A. U) �' n CYO' U' LLW, x '��f'jFi ttJJ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N 0 N f\ � ro O Q 0 Lr7 o: '" (A 2 IUD Q M 0� U a00 Q z LULU O1�0 d' 0, �o W0 za o: C8O z o� zwW� 0 W Z J J U) 8 LLJ W �Wo L L1 ? o Q 8 � O f s z -0 Z Ln J z o ? N U F_ a LU W ¢Ra N oQO< k W< < Q Cr' �oW� �fo $o Z LU N o _l Ln 1-4t.. 5 L1J Q z a = o W o Luigi Z CD 00 N z a N� 0 g LU = ¢Z LU r•-, ,-�I a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0, 10 O SHEET NO. SN ROOF DIAPHRAGM NAILING SCHEDULE RIDGE LINE + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + o + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 4 + + .0" PP.) + + + + + + + + + + + + + + + + + + + + + + + 4 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ +++ ++++++++ + cs' 15/32" CDX PLYWOOD OR 7/16" OSB BRIDGE LINE 140 MPH (1.110 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & + + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER 16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH 0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER 2 INCH NAIL LENGTH 21NCH NAIL LENGTH NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAYBE USED 1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. 2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. 3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. Backer and Filler Block Dimensions BCI®Joist Backer Block Thickness Filler Block Thickness Series 3/4" orp 5000s 1.8/1.7 nee wood panels Two 3/4" wood panels or 2 x 1-1/8" or two 1/2" 6000s 1.8/1.7 wood panels 2 x _ + 5/8" or 3/4" wood panel 1-118" or two 1/2" 6500s 1.8/1.7 wood panels 2 x — + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 602.0 wood panels 2 x _ + 5/8" or 3/4" wood panel 902.0 2 x — lumber Double 2 x — lumber DOUBLE JOIST CONSTRUCTION (Not required if both loaded equally from above) Filler blocking 1/8" gap k 1) Support back of web during nailing to prevent damage to web -flange connection. 2) Block solid between joists for full length of span. 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 4) Place joists together and nail from each side with 2 rows of 10d nails 2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". DOUBLE JOIST CONNECTION N.T.S. SQUASH BLOCKS AT INTERIOR BEARING Vertical load transfer =1900 pif max along load bearing wall. Load bearing wall must stack over squash=20 blocks and Non -stacking walls wall or beam below." require additional consideration. Check local building code for appropriate 1/16" details in One 10d box areas--20 of high or--20 sinker lateral load, nail each side 10'-0" at bearing. TANK -LESS W/H CORNER OF HOME H C G GARAGE SIDE O O O 5'-011 STUB -OUT FOR O 1'-0" o o , GAS METER U O CV = • MEASUREMENTS ARE FROM FINISHED FLOOR • ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER • ROUGH -IN ELECTRIC TO LEFT (ALWAYS) -12" OFF -CENTER GAS CONNECTION DETAIL "ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4" @ 16" O.C. 7'-5" (2)16d TOENAILS 2" X 6" @ 16" O.C. 1U-8" (2)16d TOENAILS 2" X 8" @ 16" O.C. 13'-9" (3)16d TOENAILS 2" X 10" @ 16" O.C. 16'-5" (1) USP HTW20 OR (3)16d TOENAILS 2" X 12" @ 16" O.C. 19'-3" (1) USP HTW20 OR (4)16d TOENAILS 2" X 4" @ 24" O.C. 6'-1" (2)16d TOENAILS 2" X 6" @ 24" O.C. 8'-6" (2)16d TOENAILS 2" X 8" @ 24" O.C. 11'-0" (2)16d TOENAILS 2" X 10" @ 24" O.C. 13'-0" (3)16d TOENAILS 2" X 12" @ 24' O.C. 15'-4" (1) USP HTW20 OR (3) 16d TOENAILS * TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (Le. RAFTER TO RIDGEBEAM). ** SOUTHERN YELLOW PINE, 55 PSF LOADING Squash block (2x4 minimum) Bearing wall, Versa -Lam LVL or ID Glulam Beam Boise Joist Blocking Use 3" (10d) nails at 6" o.c. V/ Provide adequate bearing for each lapped joist. Odnails SECTION @ INT. BRG. WALL N.T.S. MINIMUM SPACING = 2x GREATEST KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE IN BEARING ZONES D (KNOCKOUT EXEMPTS) (see table below) D (see table below) DO NOT cut, notch or drill flanges FILL CELL STD, 900 HOOK BOND BEAM rn ......I ............. ...... STD. 90" CONT. #5 CONT. #5 BAR HOOK BAR #5 CONT. ......... FROM IF NDATION TOHIGHEST BOND BEAM BOND BEAM STEP SCALE: N.T.S. 2nd FLOOR INTERIOR/EXT WALL SEE PLAN FOR MORE INFO CONT. BASE PLATE BEARING COLUMN PLYWOOD FLOOR SEE PLAN FOR REQAblock COLUMN ANDSHEATHING PER PLAN CONNECTIONTJI TO BE CUT TO ALLOW FOR BLOCKING/TJI MASONRY WALL OR INTERIOR BRG. WALL TJI PER PLAN OTHERWISE SOLID BLOCKING TO MATCH # OF 2nd FLOOR above to bearing below. STUDS SECTION @ INT. BRG. WALL N.T.S. 1/8" min. 2" min. )Small gap max. � 4 max. Clinch nails when possible \ Tight fit a f� 2x4/Plywood/OSB web stiffener 2" (min. required when indicated or 4" max. Web Stiffener Fastener Schedule Joist BearingLocation Series I Depth I End Intermediate ® BC15000S 9-1/2" 11-7/8" 2-8d 28d 2-8d 3-8d 14" 2-8d - d BCI6000s® BC16500so 9-1/2" 11-7/8" 2-8d 2-8d 2-8d 3-8d 14" 2-8d 5-8d 16" 2-8d 6-8d BCI60s® 11-7/8" 2-8d 3-8d 14" 2-8d 5-8d 16" 2-8d 6-8d BCI905® 11-7/8" 3-16d 3-16d 14" 5-16d 5-16d 16" 6-16d 6-16d - Hangers with side nailing. - Hangers with sides not containing WEB STIFFENER top flange of joist. - Birdsmouth cuts. N.T.S. - Under 2nd floor column w/ loads higher than 15001b. BLOCKING PANEL, INTERIOR Vertical load transfer =1900 pif max. along bearing wall Required on interior walls : for vertical load transfer when load bearing - for lateral support when joists meet over wall, or wall stacks directly over wall or beam below Load bearing wall must stack over — blocking and wall or beam below.` Use 10dx3" nails at 6"o.c. for all joist blocking panel *Non -stacking walls require additional consideration. — 6A %' ROUND HOLE MAY BE CUT ANYWHERE IN CANTILEVER THE WEB. PROVIDE AT LEAST 3" OF CLEARANCE FROM OTHER HOLES MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1%" NOTES: DO NOT CUT HOLES LARGER THAN ROUND IN CANTILEVERS. 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT, DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7.1Y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. HOLE CUTTING CHART N.T.S. �When joists meet over wall, provide 1 3/4" minimum bearing for each. Plumbing t Joist I -Joist can be offset up to 3" to avoid vertical plumbing fl 3" max JOISTS OFFSET N.T.S. Backer block (12" wide min.) Nail with 10-10d nails. \Install tight to top flange. Joist hanger \ Filler block. Nail with 10-10d nails. Backer block required where top mount hanger load exceeds 250 lbs. Install tight to top flange. 1/4"-2" gap Backer Block "Top Mount" "Face Mount" Backer block shall be tight Backer block shall be tight to bottom of top flange with to top of bottom flange with 1/4"-2" gap at top of bottom 1/4"-2 gap at bottom of top flange. flange. eb stiffner as Web stiffeners are not required when tap required if hanger flange is laterally supported by joist hanger. doesn't meet height requirements 0.6 X Joist D depth I -JOISTS BUCKETS N.T.S. USP MUC 5/8"g THRU BOLT US ML R TRUSS 'OP PLATE LC TYPICAL USP MUGT15 TO BUILT-UP COLUMN DETAIL TYPICAL HUS INSTALLATION MIN. EMBEDMENT SCHEDULE FOR AND QUANTITY )F FASTENERS TYPICAL HTA 20-18 / HTA 20 INSTALLATION A/C CHASE 4" PVC SLEEVE THRU STEM WALL SLEEVE THRU STEM—/' SEE PLAN FOR--'°. a .. . a FOUNDATION INFO ^ d' STEM FOUNDATION GRADE REINF. SEE PLAN 4 wk, UNA= 4 rv1, SLEEVE THRU FOOTING MONO FOUNDATION TYP. FND. PENETRATIONS SCALE: N.T.S. HTA 20-18 / HTA 20 INSTALLATION @ MID SPAN LOCATION OF SECOND RT16 0 NOTE: UPLIFT VALUE IS BASED ON S.P.F. USP RT16 USING 16-8d x1 1/2" NAILS UPLIFT =1030# TYPICAL RT16 INSTALLATION TYPICAL MTW INSTALLATION TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION PLUMBING LINE PVC OR SCH40 SLEEVE 17%1 r%r- \ /r-r%-ri A 1 TI Ir11 1 r-\ Ir% TOP (2) #5's x 4'-0"— CENETERED @ PIPE PENETRATION PVC OR SCH40 SLEEVE PLUMBING LINE d . a' a'd : •d d SEE FND. PLN. SIZE & REINF. PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE CENETERED @ PIPE PENETRATION PLUMBING LINE 7 d a' .d dC a a. . d d a G a d a � T a SEE FND. PLN. SIZE & REINF. Z�® Z <•Q J a IDv� 4 w . p U — 0 w D_N E � V)v / o••— o O cM o ,V U W F —c0i �M C M Cl) NZ3M Ooo _ a) U4 F 00 JCL o Qrn `o a 'T d<o A1 B ®® NC,B-D -C � °a'•yb L2') to � NI° L'�k4 w M N v: z§ ... w U; � R1 LL o¢. & All- WL N�sr N°•rJ� IW N 'A M �N, To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD O Z N O N � 1.4 +-' O H I) M O QU-)T(3Ln 0- V 'i Q LU_ CL �'-- M oC U Q 00 � Q tD Z J� W~ �- mi OZ �o W� za 4 � � z8o 11, U �w �oZZ Lq a O n LU cf) R�S W N 11z N LLJ ? o U Z Ln0 w a O z Ln f° L Ln Q o o > ('V z J Q U to V o� ¢�07 m J dos, N C/) Zu,Eo� Q wzZ¢ Z; Uo $off" Z N N =oz J ��—{ W CW G OWU wF'8 O � 2: <L Q z < � Z * k 00 N Z Z Ln Z co� = Qo ,--I a- to F SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 0 SHEET NO. SN 1 FOR UNDERLAYMENT REQUIREMENTS SEE R905. 12 P') VARIES / 5/8" OR 1/2" HIGH-J STRENGTH CEILING BOARD PER CODE (OR 5/8" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM ABOVE) W/DRYWALL SCREWS @ 7" O.C. CEILING & 8" O.C. WALLS INSULATION PER —� CHART ON FLOOR PLAN 1x2 P.T. HORIZONTAL NAILER STD. 90'HOOK (SEE DETAIL (1) LAYER TYPE II (#30) UNDERLAYMENT FOR ROOF PITCH >4:12 (2) LAYERS TYPE I OR TYPE 11 (#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. PRE ENGINEERED WOOD TRUSS @ 24" O.C. U.N.O. HURRICANE ANCHOR @ EACH TRUSS (SEE UPLIFT SCHED.) W/ METAL PL. UNDER EA. TRUSS MOISTURE BARRIER SHINGLE ROOF 7/16" O.S.B. MIN. SEE ROOF NAILING SCHEDULE ON SHT. SN1 ELEV. VARIES ALUMINUM DRIP EDGE ALUMINUM FASCIA N.O. 2x SUB FASCIA EE SOFFIT SHEET 8"x8"X16" KNOCK -OUT BLOCK W/ 1#5 CONT. FILLED SOLID W/GROUT �8" C.M.U. TYPICAL TYPE 'IS" MORTAR ARCHITECTURAL FINISH 1x2 PT WDFURRING @ 24" O.C.-/ 00 COMP. SOIL. ° (COMPACTED TO 95%-- MODIFIED PROCTOR ASTM D1557) 3" MIN. CLR• (2) #5 REBAR CONT. ON 3" CHAIRS TYP. 4" 1. 4" STD. 90 HOOK (SEE U.N.O. DETAIL) TYPICAL WALL SECTION rA SCALE: 3/4" = V-0" 53 1/2" GYPSUM WALLBOARD (1) #5 VERT. IN FILL CELLS (SEE U.N.O. FOUNDATION PLAN FOR LOCATIONS) 1x4 P.T. BASE NAILER 4"x4"INSPECTION 31/4" BASEBOARD PORT AT EACH FILLED CELL TYPICAL MIN. 2500 PSI CONC. SLAB AT GARAGE CONTRACTOR MIN PSI MAY VARY PER TO CUT BLOCK OR POUR MUNICIPALITY. CURB DUE TO SLOPE CONCRETE SLAB W/ 6X6 �- NOTE:EXTEND W1.4XW1.4 WWF OR DECO FINISH 4" to 6" "FIBERMESH" BELOW GRADE ° D Z M• D 00 6 MIL VAPOR Z BARRIER �r 4 � OPT: DEPRESS SLAB 5 2" DEEP AND 6" BEYOND DOOR TO RECEIVE PAVERS / DRIVEWAY CONCRETE SLAB PAVERS-� 2x #2 SPF STUDS @16" O.C. W/ (2) 16d TOENAILS T & B 2x P.T. PLATE--\ (2) #5 CONT. ON 3" CHAIRS (TYP.) D I o (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. s V-6".. (2) ROWS 2x BLOCKING @ 3rd FITS FOR WALL HGT. > V-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z APPLICABLE. 1/4" DIA. X 31/4" TAPCONS @ 24" O/C & c @ 6" MAX FROM END OF 2 x PLATE E 6x6W1.4xW1.4 r WWF OR FIBERMESH 411191 1=111- o 1 II -III=' ;- TYPICAL INTERIOR BEARING WALL W/OUT UPLIFT GG SEE TYP. WALL SECTION SCALE: 3/4"=V-0" S3 FOR ADDITIONAL SLAB INFORMATION. LOAD BEARING OR EXTERIOR WALL SEE CC/S3 OR — G/S3 FOR ANCHOR BOLT INFO. (IF NO UP LIFT ON WALL SEE GG/S3) *USP SPT22 TYP. - MONO OR STEMWALL— FOOTING MONO SHOWN FOR CLARITY NOTE: *FOR BEARING WALL W/ UPLIFT ONLY 5/8"OR 1/2" HIGH STRENGTH --� (U.N.O.) (OR %" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM ABOVE) S.P.F. DOUBLE TOP PLATE 8"x8"x16" NOMINAL BLOCK WITH 3/8" MORTAR BETWEEN COURSES USP SPT24 CONNECTOR 1/2" CDX PLYWOOD OR 7/16" O.S.B. SHEATHING REQ'D. FOR ALL EXTERIOR OR SHEAR WALLS AS INDICATED ON THE PLAN. ATTACH SHEATHING W/ 8d COMMON NAILS @ 4" O.C. @ BOUNDARIES, 6" O.C. @ 3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD SLAB & BLOCK 5/8"° x 10" "J" BOLT @ 24" O.C. W/ 2"°x3/16" PLATE WASHER (TYP.) ELEV. 0'-0" (ALT: 1/2"x12" TITEN HD @ 24" O.C. OR 5/8"x10' WEDGE ANCHOR AFF 211 @24"OC °..d.. ° P.. ° :° ELEV.-0'-31/2" z �31/2" MIN. d' Q. Q ° ... ° d' ° 4 4 . a . ° d °. .. ° ° 4 Q A.F.F. O 0 D 2x4 CONT. °_ °. °Od.''d ° : ° LL .' .a .. a d a 00 I n „ TRUSS BOTTOM CHORD OR 2x4 BLOCKING 5/8"OR 1/2" HIGH STRENGTH - W/ 2-16d TOE NAILS @ EACH END s „ „ (U.N.O.) (OR / GYP. TYPE X„ @ SEE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) TRUSS ALIGNED WITH STUD BELOW S.P.F. DOUBLE TOP PLATE 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. USP SPT24 CONNECTOR (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd FITS FOR WALL HGT. > 8'-61'. INSULATION PER CHART ON FLOOR PLAN USP SPT22 CONNECTOR 5/810 x 10" "J" BOLT @ 24" O.C. W/- 2"°x3/16" PLATE WASHER (TYP.) 2x P.T. BOTTOM PLATE (ALT: 1/2"x12" TITEN HD @ 24" x 6 W1.4 x W1.4 O.C. OR 5/8"x10' WEDGE ANCHOR WWF OR FIBERMESH @ 24" O.C.) 31/2" MIN. 4" ° a a . 31 /2 (mm.)- 4 GARAGE DEPTH VARIES d... �. (2) #5 CONT. 4n I I�i 1 1 r 1, GARAGE SLAB AT STEP rB TYPICAL BEARING WALL" STEP C� SHEARWALL SCALE: 3/4"=T-0" 2x S.P.F. STUDS @ 16" O.C. 2x STUD 8" C.M.U. 1 " x P.T. STUD #5 VERT. IN FILLED CELL N 5/8"x6" "J" BOLTS BOLT @ 24" O.C. VERT. OR 5/8" x 6" EPDXY BOLT OR (6)1/4"x31/4" TAPCONS SPACED EVENLY 2x P.T. PLATE ASSUMED FINISHED GRADE z o. M 00 D o D I —III —III —III —III —III _I o 0I—III—III—III—III- I=III =III —I I I=III=111=11 2 g o D D I I lil i i iTl III 1i1111i1 III 1i11111 l; T — I III I—III—III-1 II —III —III — FRAME WALL TO C.M.U. WALL CONNECTION SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" S� SLAB INFORMATION. 6x6W1.4xW1.4 31/2" WWF OR FIBERMESH min.) 4" ° ' GRADE 00 _ ! ..q _ ICI —ICI ICI '� �• - -(1) #5 REBAR W/ OPT. MIN. TYPICAL THICKENED SLAB EDGE L SCALE:3/4"=V-0" S3 BLOCK WALL BEYOND BLOCK WALL BEYOND EXPANSION JOINT 14" — O.H.D. RECESS z 13" •9 O.H.D. RECESS � N M . �. N . a• , :. •� a:` `� i •! •. �, 111�':�'.r I.. „y, a • ' _I II— •d •.. _. - All 0o e. Y I -1 —=I _ •' A I 1 : ' ' 4" I -' SEE A/S3 OR J/S6-� -1I I FI I I ICI i I I I Lli= FOR REINF. INFO. 3" MIN. CLEARANCE 1' 4" (1 STOR / V-8" (1 STORY W/ DEPRESSED SLAB OPT.) 1' 8" (2 STORY) GARAGE DOOR SLAB RECESS �•1 SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. SEE A/S3 OR J/S6 J LI 111 i I, I I I FOR REINF. INFO. 3" MIN. CLEARANCE 1'-4" (1 ST RY) V-8" (2 ST RY) GARAGE DOOR SLAB RECESS SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING - NAILED W/ 8d COMMON NAILS @ 4" O/C BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. (2) ROWS OF 2x BLOCKING @ THIRD POINTS "SHEAR WALL" SCALE: 3/4"=V-0" GV� GN�N�as 2x STUDS @ 16" O/C �- ISULATION PER CHART ON FLOOR PLAN 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W! TOTAL THICKNESS 7/8" OVER CONTINUOUS TO FOOTER BELOW 90 Fi00K DETAIL 5/8"° x 10" "J" BOLT @ 24" 0/C W/ 2"°X 3/16" METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. PLATE WASHER TYPICAL 3RD LAYER 1/8"THICK. K.O. BLOCK SP SPT22 @ EA. STUD MIN. 2500 PSI CONCRETE SLAB W/ TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ 2-16d TOE NAILS @ EACH END SEE UPLIFT SCHEDULE FOR UPLIFT CONNECTIONS. PROVIDE (1) USP HTW20 WHEN TRUSS ALIGNED WITH STUD BELOW —2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. --(1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd FITS FOR WALL HGT. > 8'-611. —INSULATION PER CHART ON FLOOR PLAN --USP SPT22 CONNECTOR /2x P.T. BOTTOM PLATE 6x6W1.4xW1.4 I WWF OR FIBERMESH 00 - I12 I (2) #5 CONT. 14,1 " i ►'�''"'' I=, _ (3 '1/ '2' 1 11 U.N.O. MIN. 1/2"(min.)- 4" TYPICAL BEARING WALL @ STEP CC SCALE:3/4"=1'-0" S3 NOTE: SEE SECTION C/S3 FOR ADDITIONAL INFORMATION USP SPT22 CONNECTOR 2x P.T. PLATE SPACE ANCHOR 6 x 6 W1.4 x W1.4 WWF OR 2X P.T. PLATE 20" MIN. LAP [24" MIN. LAP] #5 REINFORCING BOLTS 6" MAX FROM FIBERMESH WEEP SCREED INSTALLED BAR w END OF 2" x PLATE c PER MANUF. Z_ FINISH GRADE 00 #3 OR #4 REINFORCING BAR GRADE 40 MIN. F - 40ksi #3 & #4 LAP SPLICE r [GRADE 60 MIN. Fy= 60ksi] 25"MIN. LAP LAP] w W _j gI D D T a Moil _ _ D • _ _ _ [30"MIN. W ill 1L 11ZII 6 MIL VAPOR BARRIER - I I D ° I j — — I= n CO1- i e•_-111 _ #5 REINFORCING BAR R 1 7/8 D I11k r #5 LAP SPLICE COMP. SOIL. (COMPACTED TO III D ° • - I I I=�= 95% MODIFIED PROCTOR ASTM D1557) I I I I ri i I I I I 4" 1'-4" TYPICAL EXTERIOR FRAME WALL FOOTING SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" SLAB INFORMATION. P.T. 2x 1/2" GYP. BD. 2>, HOLD GYP. BD. 1/2" FROM SLAB O,-0n J CONT. BEAD SEALAi ° a . INTERIOR q�1/2 -31 a CONCRETE NAILS W 1 EMBEDMENT @ 12" O.C. STAGGERED, FROM BOTTOM PLATE TO CONCRETE (MIN. SHEAR 180# MIN. TENSION 120#) CONCRETE SLAB 00 M 6 MIL VAPOR - -� i' BARRIERIT 2X STUDS @ 24" O.C. U.N.O. GARAGE 1/2" GYPSUM WALLBOARD U.N.O. W/ DRYWALL SCREWS @ 8"O.C. INSULATION PER CHART n ON FLOOR PLAN CONT. BEAD SEALANT c 6x6W1.4xW1.4l WWF OR FIBERMESH �, a' I i 36" MIN. LAP [36" MIN. LAP] 10" #6 REINFORCING BAR #5 STD. 90 HOOK #6 LAP SPLICE REBAR DETAILS rF SCALE: N.T.S. S3 FRAME -DOWN FALSE BEAM W/ (3) SEE PLAN 10d NAILS TO TRUSS TOP CHORD SEE ROOF PLAN FOR TRUSS AT 24" O.C, MAX. • x CONNECTION INFO SEE PLAN FOR ` . & LAYOUT DESIGN TOP OF BEAM SEE ROOF PLAN « FOR STRUCTURAL (2) #5 CONT.=1 ON 3" CHAIRS 8" 1,_4., (TYP.) T BEAM SIZE & %P.T. CONNECTION INFO 7/18" I .I 2x4 #2 SYP P.T. FRAMING W/ MIN 7/16" O.S.B. SHEATHING COLUMN LOCATION Z ATTACHED PER NAILING w a SCHEDULE w � w 0'-0" FIN. FLR.�VV 'T ih SEE FLOOR PLAN FOR STRUCTURAL COLUMN SIZE & BASE CONNECTION INFO. SECURE 2x4 P.T. BTM. PLATE W/ 1/4"x3" TAPCONS AT 8" O.C. TRIM PER PLAN SQUARE CMU BLOCK BASE, SIZE VARIES PER PLAN W/ MIN. (2) #5 VERTICALS FILLED SOLID BRICK PAVERS or SLAB PER COMMUNITY SPECS (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. <_ V-6". (2) ROWS 2x BLOCKING @ 3rd FITS FOR WALL HGT. > 8'-6". 112" GYP. WB (MIN.) @ GARAGE SIDE IF APPLICABLE. 5/8— EXPANSION BOLT @24 " O.C. W/ 7" EMBEDMENT (MIN. SHEAR 3501 MIN. TENSION 2600#) _ E 6x6W1.4xW1.4 WWF OR FIBERMESH r 4t D. O IIID� 8" TYPICAL INTERIOR BEARING WALL W/ UPLIFT rG SCALE: 3/4"=V-0" S3 4 /+NI nCPar-O[• rnn VARIES G - C 1AM A ., IAM A J ' v" • • v OPTION #1 SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. �— SLAB STEP & RECESS as S.G.D. � M SCALE:3/4"=1'-0" S3 MASONRY WALL AND PAD FOOTING 8" MASONRY WALL EXTEND FILL CELLS c TO FOUNDATION PAD _ CONT. FOOTING STEEL MAT REINFORCING. r ' M 00 GRADE _ .�—m—IT•-- Uj I I I —III ' ° d I —III —III —III —I Z Imo- w 1=1 I I —I I I I=1 —I 11=1 I I W o �; cwi� w-EI 1=1 a I 1=1 1=1 1 Z 0 0 III=1 ! .. ''a . -III III—III—III—III—i I I III —III —III— FOOTING 11-III—III=III=III ,II ...III -III BEYOND PAD REINFORCEMENT (SEE SCHEDULE) 3" MIN. CLEARANCE FOOTING WIDTH SEE SCHEDULE PATIO COLUMN FTG. DETAILrN\� SCALE: N.T.S. S3 Z M Z Q 13 C Q) 4-J W (6 0 �U — W 0 I- Of ft/ I v , Z:)O y_ o co m o W 1— E —8 0) Cl) cc -,'a M O`oo = ai I N _ _ U_ co Y r Ly a)to Q CM Q O M<0 A [ N•C B1 .CA ta��llll D� o z °0���,► �tt «Lo Lu LU ✓ /�aC ! i 20 LLg .S m S 8 F L �aa..a.•• -. ESSE' 111 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 1f O O Z N O�� ro CD > U0 11710 � f0 Ln � L Q � LA U_ C- _ ro M I� U C Q001, Z � � W _j�~ =z o W z<E a� v, _l UQon: to z O Q Z uj W LU ,z z L4 II� O LU W W N J J ,z0 oZ Z z Q }o <z Ln g z -0 07� V � Z) fQ L � /�� L / L o > N 0 0 z OU Q Zzo lu o5 O U�86 Z¢o°d [V LL w �a z a Z N ff a2� J W Q Z �oZ 8 2! oQQ z l0 00 Z Z aZ J o o J = az 0- U0 SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 200 SHEET NO. S3 (MONO) J 12 �(`rYp) SEE ELEV. USP SPT24 @ EA. STUD CRICKET AS REQUIRED SINGLE 2x CONT. BASE (2) 2x6 OR (2) 2x8 TOP PLATE SEE PLAN (2) 2x HEADER TO SIT 2x6 12x8 WALL BEYOND FLUSH TO THE OUTSIDE SEE PLAN FOR HEADER SEE PLAN FOR SIZE CONNECTION 2x DEAD WOOD @ MID POINT w/ (3)12d TONEAILS SPACED DOUBLE 2x TOP EVENLY PLATE HEADER FLUSH TO OUTSIDE OPTION 2x BLOCKING @ EACH END W/ 10d @ WT4" O.C. FROM EACH HEADER FACE O BLOCKING (2) 2x HEADER PER PLAN 2x BOTTOM PLATE W/ (1) 10d @ 8" O.C. TO EACH HEADER FACE 2 x 6 (MIN.) FRAME WALL HEADER DETAIL SCALE: N.T.S. SL� SEE TYPICAL WALL SECTION PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2x4 SPF. #2 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT. TOP PLATE W/ (2) 12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ (3)10d TOENAILS T&B AS REQ'D 2x BLOCKING @ MID POINT EVERY OTHER + + STUD W/ (3)10d NAILS PLATE W/ (2)16d TO TRUSS BELOW 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" 0/C FIELD USP SPT22 @ EA. STUD 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W/ 8" EMBEDMENT 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 90^ HOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL K/S4 SEAT FOR BLOCK IS POURED, IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERALNOTES SLOPE FORWARD FOR DRAINAGE BLOCKING (TYP.) -ROOF TRUSS PLIFT CONNECTOR (SEE SCHEDULE) OISTURE BARRIER SCALE: N.T.S. SEE PLAN FOR FOOTING DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T.S. VENT OR 2ND FLOOR 1/2" MINIMUM CEMENT FINISH TYPICAL C.M.U. WALL STANDARD 3" DIA. TEE 3/4" FURRING STRIPS THREADED 3" DIA. EXTENSION 1/2" GYPSUM BOARD SCREW OFF CAP (3" DIA.) W/ DRYWALL SCREWS FOR CLEAN -OUT @ 8" O.C. OR 4d MIN. EXTENSION FROM DRYWALL NAILS EXTERIOR FACE OF BLOCK WALL IS 1 1/2" MAXIMUM EXTENSION FROM EXTERIOR FACE OF BLOCK WALL IS 21 , DRAIN WALL CLEAN -OUT rA SCALE: N.T.S. S4 REFER TO WINDOW PRODUCT APPROVAL SHEETS FOR INSTALLATION INFORMATION BY MANUFACTURER. TYPICAL SECTION THRU WINDOW KNOCK -OUT NOTCH LINTEL WHERE REQUIRED BLOCK WI (1) #5 FOR CONCRETE PLACEMENT J 11 ° e 9 .e d .. a e °- a. .a a e 8STD. 90 HOOK 8" LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS GREATER THAN V-0" WIDE (U.N.O. ON PLAN) OPENING FILLED CELL W/ (1) #5 VERTICAL SEE FDN. PLAN FOR LOCATION NOTES: 0 FILL LINTEL AND ALL CELLS ABOVE LINTEL, NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. 0 VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY. Q3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. ® OPENINGS LESS THAN OR EQUAL TO V-0" IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN. TYPICAL FILLED LINTEL ASSEMBLY SCALE: N.T.S. WIDTH OF OPENING VARIES 411 FORM CONCRETE INSET TO CREATE A SOLID BASE FOR 1/2"X91/2" PLYWOOD BLOCK WALL ABOVE, SCRAP MATERIAL _ a T' W O FORM CREATES CONCRETE RECESS TO 2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. KEEP STIFFENER BACK FROM SIDES ENOUGH TO ALLOW SPACE FOR FLAT MASONS TOOLS (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) MOUNTING BASE SHOWN IN POSITION GARAGE ENTRY FORM DETAIL 2x6 MOUNTING BASE SCALE: N.T.S. �8x8x16 C.M.U. GARAGE DOOR TRACK MOUNTING BRACKET GARAGE DOOR ROLLER GARAGE DOOR TRACK CONNECTION ASSEMBLY GARAGE FLOOR TRAVEL DIRECTION OF GARAGE DOOR MOUNTING BASE DETAIL I ° SCALE: N.T.S. ° POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED FOR GARAGE DOOR AND WATER GARAGE FLOOR. SHED FORWARD THIS DRAWING. PARTIAL INTERIOR ELEVATION SCALE: N.T.S. 7 5/81, 8" 7 5/81, 8" 7 5/81, 8" SOLID AREAS ARE ❑ ❑ STEEL AND GROUT ❑ ❑ INTERIOR WALL q ❑ ❑ CL DOOR OPENING DOOR OPENING EXTERIOR ❑ ❑ ❑ WALL ❑ ❑ ❑ ❑F111 ❑ 1ST COARSE 2ND COARSE 3RD COARSE MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOOR JAMB WALL IS TO BE WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. MASONRY LAYOUT rD SCALE: N.T.S. S4 VERTICAL JAM SOLID AREAS ARE STEELAND GROUT FULL 8x8x16 BLOCK DOOR OPENING -C 5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) BOTTOM CHORD OR 2x4 TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO [TRUSS BLOCKING W/ 2-16d TOE NAILS NOT TRANSFER LOAD. @ EACH END ° WALL ° ° 4 DOOR STOP LU W ° ° MOLDING _? a ° 2x TOP PLATE '- U) GARAGE 2-16d NAILS @ 24" O.C. OR DOOR Z] EQUAL TO TRUSS BOTTOM CHORD OR BLOCKING 2 x 6 P.T. 2x STUD @ 24" O.C. MAX. ROVIDE P.A.F. NAILS OR 2x P.T. PLATE EQUAL @ 12" O.C. SEE A/S3 FOR STAGGERED FROM BOT. PLATE TO CONCRETE REINF. INFO. W/MOUNTING ANGLE NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. TYPICAL INTERIOR NON - BEARING WOOD FRAME WALL TYPICAL GARAGE DOOR BUCK rK SCALE: N.T.S. S4 SCALE: N.T.S. S4 T�� SFF Ow N 2x CRIPPLES @ --� 16" O.C. W/ (2)12d TOENAILS T/B USP SPT4 w/ (6) 10dx1Y2"@24" O.C. 10d NAILS @ 8"— O/C TYP. DOUBLE 2x CRIPPLE STUD TYPICAL (U.N.O.) HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS SIZE JACKS STUDS JACKS STUDS EA END EA END EA END EA END 1'-4' (1) (2) (1) (2) (1) USP LSTA30 4'-9' (2) (3) (2) (2) (1) USP LSTA30 9' -16' (3) (4) (2) (4) (2) USP LSTA30 FLAT STRAPS PER CHART ABOVE TO BE BENT OVER TOP PLATE ** HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"x10" OR GREATER HEADER 1R (2) 2x HEADER SEE PLAN S� - INTERIOR HEADER BOX HEADER (1) 2x SILL PLATE W/ (2) ONLY 12d TOENAILS. EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE '--2x STUDS TYP. USP HTT16 TYP. U.N.O. SEE N/S ** HOLD DOWN CONNECTIONS Op'000,4 NOT REQUIRED @ BEARING FNiN� WALLS NOTED WITHOUT UPLIFT P.T. BOT. PLATE WALL HEADER DETAIL Q SCALE: N.T.S. SLI. SPT4 2X STUDS @ 24" O.C. P.T ATE SEE TYPICAL WALL SECTION 12 PRE-ENGINEERED WOOD TRUSSES @ 24" O/C (TYP) SEE ELEV. UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2"x4" S.P.F. TOP PLATE 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. /-CRICKET AS REQUIRED USP SPT24 @ EA. STUD 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" BLOCKING ) O/C FIELD 2X4 PT STUDS @ 16" O.C. (2) 2X4 PT STUDS UNDER HIP CARRIER/GIRDER TRUSS USP HTA20 @ EA. STUD MAIN SPAN MOISTURE BARRIER ROOF TRUSS UPLIFT CONNECTOR 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. (SEE SCHEDULE) AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 900 HOOK IN K.O. BLOCK ALT. KNEEWALL ABOVE MASONRY WALL DETAIL PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON PSPN516Z w/ (12)16d NAILS TOP SPLICE 2 ROWS 10d @ 3" O.C. (14 NAILS TOTAL) EA, SIDE OF . ' 48ySPLICE STAGGERED ATTACH ALL -' EXTERIOR STUDS W/ 4)16d TOENAILS TO OP PLATE NOTE: PLATE LENGTHS MUST BE BOTTOM SPLIC AT LEAST 4'-0" LONG. TYPICAL OVER STUD TOP PLATE SPLICE DETAIL rM SCALE: N.T.S. S4 F= 2240 LBS USP USP SPT4—]SPT24 C SPSPT4 --� . TRANSOM FRAMING SEE SECTION AA/S1 AND BB/Si FOR ADDITIONAL DETAILS RECESS LINTEL d INTO TRANSOM FRAMING [USP SPT22 SPT4 USP SPT4 A ° ° 2X81P.T. BOTTOM P TE 5/8"x10" "J" BOLT @ 24" O.C. MAX. C (MIN. (2) PER BOTTOM PLATE) USP USP SPT4 SPT24 SP S U S TRANSOM FRAMING SEE SECTION AA/81 AND BB/Si FOR ADDITIONAL DETAILS RECESS LINTEL NAILED INTO TRANSOM FRAMING USP SPT22 SP SPT4 ° a ° nD I I � 2X8 P.T. BOTTOM PLATE I I 5/8"xl0" "J" BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) SCALE: N.T.S. 2X TOP PLATE OVERLAPPING —10d NAILS @ 6" STAGGERED J-BOLTS @ 24" O.C. MAX —2X P.T. PLATE TRUSS ABOVE % - 2X BLOCKING O -(2) 16d TOE NAILS EA. BLOCKING ' 2X8 WALL ABOVE ENTRY K.O. BLOCK W/(1) #5 CONT, & FILLED 5/8"X10" J-BOLTS @ 2'4' O.C. MASONRY WALL PT4 10d NAILS @ 4" 10d NAILS @ 6" O.C. STAGGERED A STAGGERED TRANSOM FRAMING 0 o BEYOND. L.PLYWOOD PLYWOOD FASTENED TO TRUSSES o E SHEATHING WITH 8d COMMON WIRE NAILS @ 4" S4 O/C BOUNDARIES 6" O/C EDGES B & 8" O/C FIELD PLYWOOD SHEATHING MASONRY SP WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. PT4 MAX. (MIN. (2) PER BOTTOM PLATE) ALTERNATE: 5/8" DIA. ATR EPDXIED MIN. 6" INTO BOND BEAM @ 24" O.C. FRAMING DETAILS ABOVE ENTRY R SCALE: N.T.S. S4 U(_L2 Z M 0 ID Z z a - I 60 Z IDVJ cn 4--J w �_ p •U — 0 LL, Tm E CLI rV !J rr^^ , ~ v to o O �mr U QM W E min - c� N M N 6 M O o0 2 ai Ua) r- U_ ao 1� (0Qo Q rn U) o q. a A B 1 D® N•C B D C � 0 g444"' l . :O f b.- 4 'e- <) g ; :� ` 0 21, QZF r .• S\ C) � To the best of the Engineer flb e, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N O 2 I, f> rn Q "M Ln a_ Ln U_ zCL IQ- ce V CL 00 Qz � Z � WI- C J �R w� za �a r~ <Wx gQBo ul z 0 y�y � R 2 0 J LL N 8 Lu W I-WQ o� ZZ ¢e LO �Z 5 z -0 cp L o > (V o Z u Cl) Q oLL ¢<UR70 ANJ 0 rF w a� UaR N I� Z°doa J �Z< Q ��Wa Z LIJ Noco, Ln W (, 2 Z a LL J Q E a O l0 00 Q Z Z cc <tz aLn N LU Z az O g = SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 SHEET NO. S4 Y SP HGAM10 W/ (4)- 4"x1-3/4" WEDGE OLTS & (4) SDS 1/4" 1 1/2" SCREWS SEE STRUCTURAL SEE STRUCTURAL NOTES AND NAILING SCHEDULE FOR TOENAIL W/ (2)16d NAILS SEE STRUCTURAL NOTES AND BACKNAIL W/ (2) 16d NAILS NOTES AND NAILING BACKNAIL W/ (2)16d NAILS SHEATHING DETAIL 2"x4" �OUTLOOKER @ 24 O.C. NAILING SCHEDULE FOR USP RT16 OR EQUAL @ SCHEDULE FOR SHEATHING DETAIL 2x4 OUTLOOKER @ 24" TOP CHORD SHEATHING DETAIL EA. OUTLOOKER 2"x4" O.C. (OPTIONAL - SEE BLOCKING FOR OUTLOOKER ELEVATIONS) FIRST FOUR @ 24" O.C. SEE STRUCTURAL- ROWS 45° t 24" MAX. TOP CORD BLOCKING 45°t 2X4 CONT"L" BRACE TOP CORD BLOCKING USP RT16 OR EQUAL @ NOTES AND NAILING TRUSSES @ ES USP OR FOR FIRST FOUR FASTENED W/ (2)10d FOR FIRST FOUR ROWS 4" MAX. EA. OUTLOOKER SCHEDULE FOR EDGES OF 2x4 CRQ BRACE L @ EQUAL @ EA. ROWS OF TRUSSES @ W@ 24" 0/C. CMID OF TRUSSES @ EDGES SHEATHING DETAIL SHEATHING APPROX. 8" FROM OUTLOOKER EDGES OF HEIGHT OF SHEATHING TYPICAL DOUBLE TOP PLATE 2"x4" CROSS BRACE TYPICAL @ RIDGE FASTENED AT BRACE TO EXTEND SHEATHING TYP. 2X4 KICKER 2x8 SYP#2 "L" BRACE TO 2x4 CROSS BRACE APPROX. APPROX. 8" FROM 48" O.C. EACH JOINT W/ (3) 10d A AT LEAST S WEB @ 8'-0" O/C. EXTEND @LEAST 90% OF USP 8" FROM RIDGE FASTENED AT RIDGE FASTENED AT MAX. & (2}10d TOE NAILS @ E% A LENGTH (SEE TABLE) 2x4 CROSS BRACE WEB LENGTH & NOTCH @ SPT4 EA. @ EACH JOINT W/ 2 10d & (2) ( ) EACH JOINT W/ (2) EA. END @ 48" O.C. APPROX. 8" FROM BOTTOM CHORD (SEE STUD 10d TOE NAILS @ EA. END 10d & (2)10d TOE 2x6 P.T. GABLE TRUSS RIDGE FASTENED AT TABLE) 2X6 FRAMED WALL - SEE NAILS @ EA. END SILL 1/2" CDX PLYWOOD OR EACH JOINT W/ (2) 10d USP RT3A WITH 8-8d WALL SECTION FOR SPACING � 7/16" OSB SHEATHING & 2 10 NAILS @ •• � TP 2x4 PANEL BLOCKING ° ATTACHED END BROCK NGGER BLOCKING 1/2" CDX PLYWOOD OR 7/16" /C FOR THE FIRSTO(4) NAILS @ 6" O.. EDGES O.C.E GYPSUM WALL BOARD GABLE TRUSS OSB SHEATHING ATTACHED ROWS OF AND 12" O.C. FIELD 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 1/2" CDX PLYWOOD OR W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. 10dX3" @ 3" O/C (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM 7/16" OSB SHEATHING • AND 12" O.C. FIELD END TYP. TOP & THROUGH CHORD CORD ATTACHED W/ (2)16-d TOENAILS ATTACHED W/ 10d NAILSTNT {2)16d NAILS BOTTOM ATTACHED INTO 2"x6" P.T. PLATE 2"x4" LEDGER (MATCH BOTTOM CHORD @ 6" O.C. EDGES AND 12" 2x4 PANEL BLOCKING @ 48"A 2x4 BLOCKING W/ (2)16-d TOENAILS 2x4'7 ON TOP OF PANEL BLOCKING, WEEP SCREED SLOPE OF ADJACENT SCISSOR TRUSS) O.C. FIELD O.C. FOR THE FIRST (4) ROWS FASTEN WITH 10dx3" 4" O/C SPACED @ INSTALLED PER MANUF. 2"x6" P.T. SILL �� „ NOTCH L BRACE HERE OF TRUSSES FROM EA. END 2x4 "T" ON TOP OF PANEL @ 48" O.C. 5/8" x 10" "J" BOLT @ 48" O.C. TYP. TOP & BOTTOM ATTACHED BLOCKING, FASTEN WITH "J" MOISTURE BARRIER USP HTA20 OR EQ. @ 6'-0" O.C. TYPICAL. WEEP SCREED INSTALLED PER MANUF. W/ (2)16-d TOENAILS 10dx3" @ 4" O/C 5/8"x 10" BOLT @ 32" O.C. MINIMUM 6" FROM PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER USP HTA20 @ EA. TRUSS @ ALTERNATE USP LSTA18 STRAIGHT STRAP @ 4'-0" MOISTURE BARRIER 2x4 LEDGER (MATCH BOTTOM O/C ALIGNED WITH GABLE WEB. ATTACH TO TRUSS CHORD SLOPE OF ADJACENT VERT. WEB 0/C MAX.) W/7-10dx1 1/2" AND TO MASONRY W/ (3) 3/16"x 21/4" TRUSS) NOTE: IF EMBEDDED TAPCONS. SECTION STRAP MISSED VERTICAL SECTION 2 SECTION (a�� WEB; USE MSTAM36 ON OUTSIDE SCALE: N.T.S. CJ'CJ SCALE: N.T.S. SS SCALE: N.T.S. S5 REFER TO DETAIL J ON SHEET S5 FOR `= SEESTRUCTURAL— ON AND TOP r M NOTES AND NAILING CHORD BLOCKING N SCHEDULE FOR INFORMATION `O 00 SHEATHING DETAIL Ill. 1/ ". 2"x4" CROSS BRACE WOOD TRUSSES 0o I0 APPROX. 8" FROM RIDGE FASTENED AT 2x4 RAT RUN BRACING EACH JOINT W/ (2) AT 24" O.C. ON TOP OF 1 1 2 1 1 2 10d & (2)10d TOE BOTT. CHORD FOR 4 NAILS @ EA. END TRUSS SPANS ATTACHED W/ 2 -16d 2x4 PANEL BLOCKING AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF @ 48" O/C FOR THE OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS FIRST (4) ROWS OF 2x4 BLOCKING @ 24" (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL TRUSSES FROM EA. O/C W/ 2 -16d (D = 0.207", L = 41/2") OR EQUAL END TYP. TOP & TOENAILS @ EA. END NOTES: BOTTOM ATTACHED 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL W/ (2)16-d TOENAILS MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) EXT. WALL CONN. @ 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION NON -LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SEE TYP. WALL SECTION FOR SCALE: 3/4" = V-0" SS TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 ADDITIONAL INFORMATION. SCALE: N.T.S. S5 2"x4" OUTLOOKER @ 24" - O.C. W/ (2) 10d PER JOINT IINIMUM 2x ;ROSS BRACING PRE-ENGINEERED 3EE PLAN FOR WOOD TRUSSES OCATIONS) 10dx3" O/C 2"x4" TOENAIL 6" O/C RUNNERS W/ (2)16d TYPICAL (2)16d PER NAILS 12' MAX JOINT .,.,,. , ,,............. , , .,.,..,.,, ... �, 2"x4" MIN. SEE M/S5 CROSS BRACING DETAIL 1 95� 12 6.9 1 MAX. , SCALE: N.T.S. S5 GABLE TRUSS ALTERNATE NON -DROP GABLE END DETAIL SCALE: N.T.S. 'IL" BRACE W/ 10d @ 4" O.C. (SEE SCHEDULE FOR SIZE AND LOCATION) S5 CONT. BEARING GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. BACKNAIL W/ (2) 2x4 OUTLOOKER 16d NAILS @ 24 O/C TOP CORD BLOCKING FOR USP RT16 OR FIRST FOUR ROWS EQUAL @ EA. OF TRUSSES @ OUTLOOKER 24" MAX. EDGES OF SHEATHING TYP. "L" BRACE TO EXTEND AT LEAST 90% OF WEB LENGTH (SEE TABLE) GABLE TRUSS 1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING ATTACHED W/ 10d NAILS @ 6" O.C. EDGES AND 12" O.C. FIELD (2)16d NAILS 2x4 "T" ON TOP OF PANEL BLOCKING, FASTEN WITH 10dx3" @ 4" O/C USP HGA10 @ 36" O.C. DBL. TOP STUD WALL PLATE (SEE TYP SEC ) 2x4 BLOCKING 2x4 "T" BLOCKING @ 48" O.C. 16d NAIL "L" BRACE ATTACHED W/ i0d NAILS @ 4" O.C. TYPICAL GABLE TRUSS WEB DOUBLE "L" BRACING DETAIL 5 SCALE: N.T.S. S5 2x4 "T" BLOCKING 2x4 BLOCKING @ 48" O.C. "L" BRACE ATTACHED 16d NAIL W/ 10d NAILS @ 4" 0.C� TYPICAL GABLE TRUSS WEB J SINGLE "L" BRACING DETAIL-6 SCALE: N.T.S. S5 DIAPHRAGM BLOCKING @ 48" O/C GABLE TRUSS TRUSS VERTICAL USP SPT24 @ EACH STUD (2) 2"x8" "L" BRACE J FASTENED WITH (3) SECTION 4 16d PER SIDE SCALE: N.T.S. S5 SCISSOR GABLE "T" BRACE AS PER HIB 91 SCALE: N.T.S. S5 2 x 4 BLOCKING W/(2)10d TOE NAILS @ EACH END @ 24" O/C (TYP) \-BRACING W/(3)10d x 3" @ • EACH CONN. @ 24" O/C MOISTURE BARRIER BOND BEAM MASONRY WALL RCHITECTURAL FINISH EXT. WALL CONN. 0NON - LOAD CLG. BEARING LOCATION UNEVEN � ) E SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5 ADDITIONAL INFORMATION. "L" BRACING REQUIREMENTS STUD SPACING NO "L" BRACE (1) 2"x4" (U.N.O.) "L" BRACE 2"4" (U.N.O.) "L" BRACE 24" 010" - T-0" 3'-0" - V-0" 6-0" & GREATER SCISSOR GABLE - (1) 2'W" #2 S.P.F. @ EACH VERTICAL AND (2) 2'W" FULL HEIGHT @ DIAPHRAGM BLOCKING NOTE: 1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C. 3) SEE 6/S5 FOR MORE INFO. OVERLAP TRUSS BRACING AT LEAST TWO TRUSS SPACES BACKNAIL W/ (2) 2x4 OUTLOOKER 16d NAILS @ 24 O/C TOP CORD BLOCKING FOR USP RT16 OR FIRST FOUR ROWS 8d @ 6"O/C - WOOD TRUSSES EQUAL @ EA. OF TRUSSES @ OUTLOOKER 24" MAX. EDGES OF SHEATHING TYP. "L" BRACE TO EXTEND AT LEAST 90% OF WEB LENGTH (SEE TABLE) GABLE TRUSS 1/2" CDX PLYWOOD OR 7/16" (2)16d NAILS OSB SHEATHING ATTACHED W/ 10d NAILS @ 6" O.C. E ES AND 12" O.C. FIELD USP HGAM10 W/(4)-3/16"x1-3/4" - JACK TRUSS WEDGE BOLTS & (4) SDS 1/4" x 1 SEE PLAN FOR 112" SCREWS CONNECTION 2x4 "T" ON TOP OF PANEL-' BLOCKING, FASTEN WITH L 2x4 BLOCKING W/ 1063" @ 4" O/C (2)12d TOENAILS SECTION g SCALE: N.T.S. S5 -MINIMUM (2)16d PER JOINT \--MINIMUM 2x4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL SCALE: N.T.S 6" OVERLAP M S5 "L" BRACE W/ 10d @ 4" O/C (SEE SCHEDULE FOR SIZE AND LOCATION) @ EACH STUD GABLE END BRACING DETAIL SCALE:3W--l'-0" MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION HIP FRAMING REFERENCE PLAN a z W a z 20'-0" MAX 20'-0" MAX "X" BRACE SEE DET. J/S5 -1 1 CONTINUOUS BOTTW CHORD BRACING 2X4 MIN. W ----w ... 4 0 Iz o ' o �t 0 W w 9O r 9 o T o g w NOTE: 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACING THAT MY BE REQUIRED 2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN AS PER BCSI 1-03 SCISSOR TRUSS SCISSOR TRUSS d /TOP & BOTTOM CHORD GABLE END BRACING @ 4'-0" O.C. MAX. FOR FIRST (4) ROWS OF TRUSSES SCALE: N.T.S. 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ 2-10d @ EA. TRUSS (NOTE: BRACING MAY BE PLACED ON EITHER TOP OR BOTTOM OF THE BOTTOM CORD) DROP CEILING FRAMING W/ DROP CEILING BRACING DETAIL MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION IERI 0 zo z Q z V) 0 (n 4--J w 0 Li-' C o o Co mCN U Lll �M m M ~ U ? N 020 fU - ILL 00 O U� Y 0)fl.o Lo O 'TQ rn M 0 A� a Do N-C-B -D-C e �q�i44� a i i +��r too itsa � • `gam To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O 0 Z o � 1. > �+ rn O M Q o Ln •L a. cnLA Q L LL ocv 000 d �� Z � LU -iC 0 �z �o z a �¢oa ��UO U O wci p W z J 0 'a z� U-) C ¢ U zZ 0 a fu Lr'iLLjg o ? N U r^ / V C 'RJ V Z ¢J Q W o "- oz < o� U.- y.� N �r LL oQoa z Q d- a ono Z N Lazo W _! LA W aWO~ �aLL1 LL �0Wo lli Q LL¢Q ~ O �O 00 <C Z Z ¢WZ k L az o 2 ¢z rn SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO. 10 SHEET NO. S5 e m 2x STUDS @ 16" O.C. USP LSTA24 STRAP W/ 8-10d x 1 1/2" NAILS TO STUD & 8-10d x 1 1/2" TO BAND JOIST @ EA. STUD 2"x BOT. PLATE W/ ATTACHED WALL SHEATHING (2)1Od @ 6" O.C. CONTINUOUS TO BOTTOM RIBBON NOTE: EXTEND SHEATHING TO 2nd FLOOR WALL BOTTOM OF BEAM OR GIRDER W/ 8d @ 4" O.C., 2 ROWS STAGGERED 2"x BOT. PLATE W/ (2) -10d @ 6" O.C. 2X4 RIBBONS, EACH W/ 4-16d BEAM/GIRDER NAILS INTO EA. FLOOR TRUSS WEEP SCREED INSTALLED PER. MANUF. USP HTA20 @ EA. TRUSS W/ 10 -1Od x 1 1/2" NAILS INTO FLOOR PRE-ENGINEERED TRUSS & MIN. 4" EMBEDMENT IN FLOOR TRUSSIJOIST FLOOR TRUSSES KO BLOCK (1) LAYER TYPE II (#30) UNDERLAYMENT FOR ROOF PITCH >4:12 (2) LAYERS TYPE I OR TYPE 11(#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. 12 PRE ENGINEERED WOOD TRUSS @ 24" HURRICANE ANCHOR @EACH TRUSS O.C. MAX. SHINGLE ROOF FOR UNDERLAYMENT SHINGLE ROOF REQUIREMENTS SEE R905. 15132" CDX PLYWOOD OR 7/16" BAFFLE O.S.B. (SEE ROOF NAILING INSULATION P SCHEDULE ON SHT SN1) CHART ON FLOOR ALUMINUM DRIP EDGE PLAN ALUMINUM FASCIA 5/8" OR 1/2" HIGH STRENGTH CEILING 2x SUB FASCIA BOARD PER CODE W/ 1 3/8" DRYWALL NAILS OR DRYWALL SCREWS 7" 0/C SEE SOFFIT SHEET CEILING & 8" 0/C WALLS ATTACHED WALL SHEATHING TO 1/2" GYP WB (2) TOP PLATE W/ 8d @ 4" O.C., 2 ROWS DOUBLE 2x S.P.F. TOP PLATE 1x2 NAILER ~ PLYWOOD SHEATHING 2X BLOCKING @ EA, WALL NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 SHEATHING JOINT FOR MORE INFO LU 16" O.C, 2X S.P.F. STUDS o = W/ (4)16d TOENAILS TO TOP PLATE 7/8" CEMENTITIOUS FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER 2x BOT. PLATE W/ (2)10d @ 6" O.C. METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD 3/4" PLYWOOD DECKING GLUED AND NAILED W/ 1 Od - 1 W LAYER 1/8" THICK. COMMON @ 6" O/C EDGES AND 12" O.C, FIELD U- = NSULATION PER 1/2" GYP. WB OR 3/8" PLYWOOD/ TYPE 2-M-W OSI3 I CHART ON FLOOR PLAN (DRAFTSTOPPING) TO BE NAILED W/8d COMMON @ 6" 0/C TO ONE SIDE OF THE FLOOR TRUSS FOR AN AREA 1000 S . B R <FT. OF FLOOR AREA & SEALED PENATRATION AREA W/ FOAM. DRAFTSTOPPING SHALL DIVIDE THE CONCEALS S6 S6 SPACE INTO APPROX. EQUAL AREAS. N// FLOOR SYSTEM --METAL SEAT 0 OR FELT PAPER FOR MOISTURE BARRIER a;a 1/2" HIGH STRENGTH OR 5/8" GYP WB (OR 5/8" GYP. TYPE " X" @ GARAGE ONLY) W/ 1 3/8" DRYWALL NAILS OR DRYWALL SCREWS 7" O/C CEILING & V O/C WALLS 1/2" GYP WB INSTALLATION PER CHART ON FLOOR PLAN NOTE: LAP SHEATHING TO BOTTOM OF BAND JOIST TYPICAL 1x WD FURRING @ 24" O.C: BASEBOARD MIN. 2500 PSI CONC. SLAB MIN. PSI MAY VARY PER MUNICIPALITY -71 M 'I I 11 -11:1r J1 6x6 W1.4xW1,4 '• d , a A' A Illl I I EllJ WWF OR FIBERMESH II�III II e. STD. 90 HOOK (SEE DETAIL) •8"x8"X16" CONIC. KNOCKOUT BLK. W/1#5 ROD CONT. FILLED SOLID W/GROUT FINISH (1) #5 VERT. IN FILL CELLS (SEE — FOUNDATION PLAN & NOTES) M v 4"x4" INSPECTION PORT AT a EACH FILL CELL TYPICAL a aW AT GARAGE CONTRACTOR N TO CUT BLOCK OR POUR CURB DUE TO SLOPE NOTE: EXTEND DECO FINISH �4'"to 6" BELOW GRADE =1NISH GRADE 00 3) # 5 REBAR ON 3"CHAIR 1�1 I I -STD. 90 •HOOK ( 4 (SEE DETAIL) W/3" MIN. CLEARANCE TYP 2—STORY WALL SECTION ,1 SCALE:3/4"=V4 S6 2ND FLOOR FRAME CONNECTION SEE J/S-6 FOR ADDITIONAL INFORMATION. USP LSTA24 STRAP W/ 8-10d x 1-1/2" NAILS TO STUD & 8-1 Od x 1-1/2" TO BAND JOIST @ EA. STUD 2nd FLOOR WALL---- BAND JOIST *USP MP4F @ 24" o.c. w/ 12-8d NAILS 1 st FLOOR WALL SCALE: N.T.S. 2"x BOT, PLATE W/ (2)10d @ 6" O.C. NOTES: * USE MP4F & EXTEND SHEATHING TO BOTTOM OF RIM BOARD/BAN D JOIST FOR SHEAR WALL ONLY. USP LSTA24 STRAP w/ 8-1 Od x 1 1/2" NAILS — TO STUD & 8-10d x 1 1/2" TO BAND JOIST @ EA. STUD 2ND FLOOR FRAME CONNECTION @ WOOD 1ST FLR. UPLIFT CAP = 928 PLF SHEAR CAP = 355 PLF SEE J/S6 FOR ADDITIONAL INFORMATION. 2"x4" PANEL BLOCKING @ 48" O/C FOR THE FIRST 8'-0" OF END WALL FROM EA. END. (TYP) TOP & BOTTOM CHORD ATTACHED W/ (2) 16d TOE NAILS DECKING — FLOOR TRUSS SEE FRAMING PLAN . • t 2"x4" CROSS BRACE @ 48" O/C FOR THE 1 ST 2'-0" OF END WALL W/ (2)10dx3" @ EA. END INTO 2"x4" BLOCKING SCALE: N.T.S SPACER BLOCKS E S6 "T" CORNER TYPICAL'IT" AND CORNER DETAILS rN SCALE: N.T.S. S6 2ND FLOOR FRAMING - SEE SECTION J/S6 ATTACHED WALL SHEATHING TO BOTTOM PLATE/CHORD W/ 8d @ 4" O/C, 2 ROWS STAGGERED FLOOR TRUSS SEE FRAMING PLAN WEEP SCREED INSTALLED PER MANUF. USP HTA20 @ 24" O.C. W/ 10-1 Od X 1 1/2" NAILS INTO BLOCKING TRUSS & MIN. 4" EMBEDMENT IN CONC, 2ND FLOOR FRAME CONNECTION R PARALLEL TO MASONRY WALL SCALE: 3/4"=T-0" S6 SEE TYP. 2-STORY WALL SECTION FOR ADDITIONAL INFORMATION. FLOOR CONNECTION @ MASONRY 1ST FLR. SEE J/S6 FOR ADDITIONAL INFORMATION. SCALE: 3/4"=V-0" RIBBONS la DETAIL FLOOR TRUSS 0 SCALE:1 1/2"=V-0" S6 NOTE: SEE TYPICAL WALL SECTION SEE SHEATHING SPECS ON FLOOR C/S3 FOR ADDITIONAL INFORMATION 1/2" GYP. W.B. MIN. @ GARAGE SIDE IF APPLICABLE (1) ROW OF 2x BLOCKING @ MID HGT. FOR WALL HGT. < 8'4". (2) 5/8"DIA. x 10" "J" BOLT Wi 8" ROWS OF Zx BLOCKING @ 3rd PTS EMBEDMENT @ 24" O.C. W/ FOR WALL HGT. > V-6" 2"DIA.X 3/16" PLATE WASHER USP SPT22 @ EA. STUD (MIN. SHEAR 3500#.MIN. TYPICAL 2 x STUDS @ 16" O.G. TENSION 260Q# 2X P.T. PLATE 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH • a. 4. .AQ. CO T 81'il I I I IF, I I1 8 I )� TI I I CHAF_ARANCEMIN. '1 INTERIOR 2-STORY FRAME SECTION f S SEE TYP. 2-STORY WALL SECTION FOR SCALE: 3/4"=V-0" ADDITIONAL SLAB INFORMATION. S6 B 15132" OSB EXPOSUREI SHEATHING D E NG AS ED PER N X-X IF LL SHEET C G FLOOR SYST M PROVID BLOCKI REQUIR SECTIO NOT FU HEIGHT (2)- 2x TOP PLATE BEYOND I 15/32" OSB EXPOSUREI F F SHEATHING w x SOLID 2x rn C BLOCKING @ ALL o C SHEATHING 0 EDGES (SEE OPENING SECTION X- ul II U C x/F-11 I = w x E w 2x STUDS BEYOND. y SEE PLAN o co \-2x4 P.T. BASE zx RIBBON OR VERTICAL A HORIZONTAL PLATE BEYOND BLOCKING SEE PLAN BETWEEN FLOOR WALL SHEATHING SYSTEM rArAr i r-r r"%rATi^Li ntAnnARA 4 FT. 4 FT. ® o 2 2 5 FT. 4 FT. O O O 5 FT. 4 FT. n 4 FT. 4 FT. O O O ( 4 FT. ROOF NAILING ZONE DIAGRAM ROOF NAILING SCHEDULE • NAILING ZONES (SHINGLE AND TILE) W ZONE 1: 8d RING SHANK NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD co ZONE 2: 8d RING SHANK NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD ZONE 3 8d RING SHANK NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD is Z (NOTE: IF 518" PLYWOOD IS USED, CONTRACTOR MUST USE 10d RING OW � SHANK NAILS) NOTE: = y ROOF SHEATHING: (APA RATED EXPOSURE 1) 1/2"PLYWOOD O W (TILE) OR 7/16" OSB MIN. (SHINGLES) SPAN RATED 24116 W rL er 00 F SHEATHING MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, ATTACH 0 y m S PER NAILING SCHEDULE. PANEL EDGES WILL NEED TO BE ATTACHED TO LL z w g „ STUD AND OR BLOCKING AT ALL EDGES. N W 0 0 a = W v A MINIMUM 1/8" SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END JOINTS TO ALLOW FOR EXPANSIONS FASTENERS SHALL NOT PENETRATE SURFACE MORE THAN 118" 318" "S" = NAIL /8" SPACING S 3/4"1/2S 112" 711 S • 1/2" SINGLE NAIL EDGE SPACING DOUBLE NAIL EDGE SPACING Q NAIL AT BASE 2 ROWS @ 4" O.C. W/8d COMMON NAIL © NAIL AT TOP PLATE TWO ROWS @ 4" O.C. W/8d COMMON NAIL @ NAIL OPENING PERIMETER @ 3" O.C. W/8d COMMON NAIL @ NAIL INT. AT 3" O.C. W/8d COMMON NAIL 0 STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C. W/8d COMMON NAIL OF SHEATHING SPLICES @ HEADER - NAIL SHEATHING TO HEADER W/ 8d COMMON NAILS @ 4" O.C. © (2) 8d NAILS @ 3" O.C. TO EACH TRUSS END OR @ VERTICAL MEMBER IF GABLE END NOTE: • 8d NAILS FOR WALL SHEATHING MUST BE MIN .131" X 21/2" • DO NOT OVERDRIVE NAILS, FASTENERS SHALL NOT PENETRATE SURFACE MORE THAN 1/8". ) AT ALL PANEL BLOCKING LOCATIONS MIN 2 X 4 #2 SPF TURNED VERTICAL W/ 7116" OSB FLITCH PLATE TO W/ (2) 12d TOENAILS EA. END. NAIL FLITCH PLATE TO VERTICAL W1(4) 8d NAILS (2) Sd NAILS @ 3° O.C. STAGGERED C WALL SHEATHING INSTALL. �Fm,n=n S6 & NAILING SCHED. SECTION X-X SF p�Npa� !qN 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2x CRIPPLES @ 2"x10" OR GREATER HEADER 16" O.C. W/ (2)12d TOENAILS T/B SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION 1 (2) 2x HEADER SEE PLAN S4 INTERIOR HEADER 10d NAILS @ 8" 0/C TYP. BOX HEADER (1) 2x SILL PLATE W/ (2) ONLY 12d TOENAILS, DOUBLE 2x EXTERIOR HEADERS CRIPPLE STUD (1) 2x SILL PLATE W/ (2) TYPICAL (U.N.O.) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE �F\ pFNi,,R�OR SEE PLAN FOR REQUIRED CONNECTIONS LOAD BEARING/EXTERIOR FRAME WALL HEADER DETAIL 2x STUDS TYP. P.T. BOT. PLATE FLOOR TRUSS / (2) ROWS OF 2x BLOCKING @ THIRD POINTS 5/8"DIA. x 10" "J" BOLT W/ 8" EMBEDMENT @ 24" O.C. W/ 2"DIA.X 3/16" PLATE WASHER (MIN. SHEAR 3500#. MIN. TYPICAL TENSION 2600#.) 2500 PSI CONCRETE MIN. SLAB W/ 6x6 W 1.4xW 1.4 WWF OR FIBERMESH E a M -I I I_I I —I I I_I ! " III —III —III I I 'Q. �I I -I I II I II I II f II 14 a: • die' —a i I I ICI I i T (3) # 5 REBAR ON 3" CHAIR 4" 1 1_8" W/3" MIN. CLEARANCE ALTERNATE FOOTING M S6 HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS SIZE JACKS STUDS JACKS STUDS EA END EA END EA END EA END 114 (1) (2) (1) (2) (1) USP LSTA30 4'-9' (2) (3 (2) (2) (1) USP LSTA30 9'-16' (3) (3) 1 (2) (3) 1 (2) USP LSTA30 PLYWOOD SHEATHING NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 FOR MORE INFO -2X STUDS @ 16" O/C 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 318" THICK EACH. 3RD LAYER 1/8" THICK. USP SPT22 @ EA. STUD -2X P.T. PLATE WEEP SCREED INSTALLED PER. MANUF. 00 FINISH GRADE I— 00 @ WOOD IST FLR. SEE J/S6 SCALE: 3/4"=V-0" FOR ADDITIONAL INFORMATION. V S6 CLUJ (9 M 0 13 Z (0 Q Od z W U-1 C) �U — 0 w O U) (Aoo U 00 n N CO LU I— O U Mal C M 2 04 O-2 � CM a) U 1:5 -00 Q rn 05 Q0 4ov rn<6 A 1 MD. r .yFi::� Ciw9 VCn O m �✓ J d�yp `00 ..ww ��y..a;ti o ir• "gym '., k` il•.� �'� OWLL i ..° Uj LU _ � Q ,e toa 0 N ��pp� k '� 21 U0 A. �•C '` IIY ..i To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O 0 Z N O 4-J >(nMO LC) Q (0 LC) a- •L :ii n 2 Ln Q L-U- CL U CL CO Q ru 0 WLU J 0, W� za Ea F- a°�ir ooz0, z W W 1. �oWz �Lu X-1 H1 � W mzo �W zz rq Ln u3 J �z Z O 5 � � F-- s o > N o U to 0 _zI �¢ a� CZ ¢ < Y�¢' X OCJ -2-. N LL- a za0J Q I�uj d- � 01� [�zo ��- Z Z w N W L0 - J T--I w w Q1= o Y 8 O �0 2: ¢ Q Z ¢8 ¢UJz 00 Z az J O o 0 g = ¢z LU d (n � SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 SHEET NO. S6 2x12 SYP ALIGN THIS STUD WITH 3/4" RISER CUT TO FIT STRINGER A FACE OF 2ND RISER MAINTAIN BETWEEN' SCAB SIDE) STRINGER 2x4 GLUED AND NAILED (EACH TO BOTTOM EDGE OF 2x12 AND ?'GAP TOP AND BOTTOM, GLUED AND NAILED TO STRINGER STRINGER MUST MAKE FULL 2x4 BEHIND RISER 1 CONTACT WITH LANDING NBLOCKING 1x4 GLUED AND NAILED TO STRINGER STRAP GLUED T O &-7 II 2x4 DRAFT RISER AND TREAD FLOOR STOP JOIST 2x8 SYP DRYWALL STOP MUST ZxZ4 NOT TOUCH STRINGERS j 7 ' 7 7 7 ALL STAIR STRINGERS AND TREADS TO BE #2 SYP (MIN.) THREADS, RISERS, AND 3/4" PLYWOOD NOT SHOWN IN DETAIL FOR CLARITY ALL WOOD TO WOOD CONNECTIONS TO BE GLUED (PL 200) AND NAILED (MIN. (2)16d). 1 314 x 11 j VL 2x4 UNDER STRINGER - GLUED AND NAILED TO LANDING 2x4 UNDER STRINGER GLUED P NAILED TO LANDING BLOCKING D 2x4 PT NOTCH--,, INTO STRINGER H 2x8 BLOCKING FOR STRAP �ix4 blocking 20" FLAT STRAP NAILED TO RISER AND E THEN WRAPPED AROUND STUD (USP MTW12) - PLAN VIEW SCALE: " = 1'-0" NOTE: THESE DETAILS ARE NOT PLAN SPECIFIC. THEY ARE PROVIDED TO YOU AS A STANDARD TO CONSTRUCT STAIRS. REFER TO PLAN DETAILS FOR RISE AND RUN INFORMATION. 3/4" RISER CUT TO FIT MAINTAIN BETWEEN 4" AND �' GAP TOP AND BOTTOM, GLUED AND NAILED TO STRINGER 2x12 TREAD GLUED AND NAILED 2x4 PT NOTCHED INTO STRINGER AND TAPCONED INTO FLOOR WITH GLUE AT STRINGER CONTACT POINTS 2x4 SPF NOSING GLUED AND NAILED MATCH NOSING ON OTHER TREADS 2x8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS 2x4 BLOCK IN KNEEWALL FOR 2x12 NAILING x4 GLUED AND NAILED TO STRINGER FOR DRYWALL SPACING H SECTION VIEW SCALE: i" =1'-0" MUM SYP 2x8 SYP 2x8 SYP 2x4CUTC,, DOES NOT BEAR IN WALL GLUED TO 2x8 F SE STRINGER MUST MAKE FULL CONTACT WITH LANDING IV I PT NOTCHED Il� D NAILED TO FLI STRINGER CON' CTION VIEW "A" 2x SYP CUT TO FIT BEARS IN WALL 2x12 SYP BEAR IN WALL 2x6 SYP 2x4 CUT ON BEVEL AT STRINGER CON' DOES NOT BEAR IN WALL SECTION VIEW "D" SCALE: 1" = V-0" FILLER STRIPS ADDED " PLYWOOD GLUED & SCREWED TO PLYWOOD DECKING SCALE: 1" = V-0" 2x SYP CUT TO FIT BEARS IN WALL �--2x12 SYP BEARS IN WALL BULLNOSE DETAIL SCALE: 1" = T-0" RINGER 2x4 GLUED AND NAILED SECTION D-D 3/4 PLYWOOD ON DECK �- 2x8 SYP GLUED AND NAILED TO FRAMING 2x4 DRAFT 2x12 STOP TREAD GLUED AND 2x4 PT NOTCHED INTO STRINGER AND TAPCONED INTO FLOOR WITH GLUE -AT STRINGER CONTACT POINTS r'7 SCALE: 1" = 1'-0" E 2x4 PT NOTCHED IP AND NAILED TO FLI 2x8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS ILUED AND NAILED TO STRINGER DRYWALL SPACING SECTION V SECTION VIEW "E" SCALE: 1" = V-0" E SECTION VIEW SCALE: 2' = V-0" 314 PLYA ON DECH --2x8 SYF AND Ni FRAMI!N 2x4 DRAF' STOP 2x4 BLOCK A BLOCKING FOR 2x12 PT UNDER 2x12 ATTACH ALL COMPONENTS OF STAIR TO CONC. W/ T" X 2 T" TAPCONS @ MAX. 32" O.C. IEW "B" SCALE: 1" = V-0" ;ER TREAD :4 GLUED AND NAILED TO STRINGER DRAFT )P 8 SYP DRYWALL STOP JST NOT TOUCH 'RINGERS G x4 BLOCKING FOR 2x12 x4 PT UNDER 2x12 C / PROVIDE MOISTURE PROTECTION ATTACH ALL COMPONENTS OF STAIR TO CONC. W/ T" X 2 t" TAPCONS @ MAX. 32" O.C. —1x4 GLUED AND NAILED TO STRINGER SECTION VIEW "C" SCALE: 1" = V-0" TOP OF STRINGER CONN. TO BOTTOM NEWEL POST LET INTO OF NEWEL POST THE BLOCK PER CONTRACTOR PROVIDE BLOCKING F-1 2X8 BLOCKING FOR NEWEL POST TO ANCHOR TO. FLOOR GIRDER PROVIDE SOLID BLOCKING (GLUED AND NAILED) 2X4 CUT ON OR 1 j4 x 16" VL BELOW ALL NEWEL POST BEVEL GLUED FROM JOIST TO JOIST. USE AND NAILED TO 2 X 12 BLOCKS, GLUED AND FLOOR LVL NAILED TO JOIST. TRUSSES NEWEL POST SECTION VIEW "G" BLOCKING SCALE: 1" = V-0" SCALE: 1" =1'-0" 0 1 HIM k oUIN0 1 MUU I IUIN Ur. I /"XI LO (IF 11 X1 7 REDUCE SCALE .5) SCALE: AS NOTED JOINT -TO )ISTS) NAILED AND TOP PLATE VTO RIM BAND, ID NAILED TO WALL BELOW JOINT -TO )ISTS) 2X USP (1 LA ECTION VIEW "H" SCALE: 1" = V-0" Ul�_ z M o O _ zco z� Q OJ ' Z U0 cn D(u w _ p U— O w N �- E o co M V U nmO w 1— E — a, Cl) ream N 0.20 U LL N N �Y a o Lo 0d Q rn CL rnQ o AI NC.H�D-C ;r ��t4 pydYiiC gOj %�o �'> • ,, o •4.,z •S o ��i LLlj, 146 01 T LL - de L �N.,o � a�J,E'I.O M t •`NN ` S S TJJI To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. i O O Z N O N n i—+ 4-0 p �>-+HMO M Q � a Ln QLU", fl_ F._ M U Q 0� 00 Q E� z J W � �- J Lz �0 3� W� Za fa r~ Qua �z00 rry�yy o z z a}�W N W m Z otnu z0 � Q U p _� 5 Ln o N o 0 U C'3 z J Q Lu z p I- IT° Q o xo6 Cc o< < LU � Q a Z Z N o,co LU J Lr) >� LU � Q �� �Z Q z 2Y< ~ O l0 00 Q Z Z tu i aLLJz a< Lnz O r� J = J 2 ¢ z uj SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION NO. 10 SHEET NO. ST 1X4 1/2" DRYWALL 1/2" DRYWALL DOOR JAMB REFER DOOR JAMB (REFER 1 X 4 ( 1 X 4 1/2" DRYWALL UNACCEPTABLE INSTALLTION 04 DOOR JAMB (REFER TO SHT. SDW2-K1 P.T. TO SHT. SDW2-K1 TO SHT. SDW2-K1 FOR CONN. DETAILS MAX. 8" DO NOT DO THIS PROPER INSTALLATION ` ' 2"x BOT. PLATE W/ (2)10d @ 6" O.C. FOR CONN. DETAILS FOR CONN. DETAILS 1 X 4 1 X 4 ♦ #5 REBAR (TYP,) 3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO 2X BOTTOM PLATE W/ 8d 4" 1 X 4 3-1/4" LONG X 3/16"0 FURRING 3116"0 X 3" LONG „ f� X 3-1/2 LONG TAPCONS FURRING FURRING #5 REBAR AND NAILED W/ 8d COMMON @ 6" O.C. EDGES AND 12" O.C. FIELD @ O.C., 2 ROWS STAGGERED TAPCON. INTO TAP STAGGERED @ 16" TAPCONS STAGGERED 2X8 (TYP) ♦ ' BLOCK@ SPACING „ 1 DETAIL 1X8 P.T. STAGGERED @ 16' O.C. O.C. 2-ROWS INTO 2-ROWS INTO 1X8 2x BAND JOIST W/ FACE NAIL 10d PER MANUFACTURE MASONRY THROUGH 1-1 /211 DETAIL MASONRY THROUGH 1� 3 DETAIL FILL STD. 90^ ♦ D. 90°HOOK (TYP.) @ TOP & BTTM CHORD, AND (8) 1x4 P.T. & 1x8 P.T. 1x8 P.T. & 2x8 P.T. SOLID BOTH CELLS HOOK (TYP.) FACE NAILS 10d @ TRUSS VERT. WEB 3/16" x 3 -112" TAPCON @ 16" 7 METAL SEAT PLATE �� 1X4 P.T. NOTE: O.C. & 4 FROM 3/16 x 3 -1/2 DOOR JAMB (REFER 1 X 4 1/2 DRYWALL y LAP SHEATHING TO DOOR JAMB (REFER EACH END W/ MIN DOOR JAMB REFER TAPCON TO SHT. SDW2-K1 FOR (IL BOTTOM OF BAND TO SHT, SDW2-K1 2" EDGE DISTE. TO SHT. SDW2-K1 CONN. DETAIL JOIST TYPICAL FOR CONN. DETAILS FOR CONN. DETAILS 10d @ 12" O.C. 1 X 4 J FURRING 2X8 P.T. WITH 3/16" 0 X 3" - ' +2„ NOTC FIRST COURSE USP HGAM10 @ 12" O.C. w/4-SDS 1/4x1 1/2" SCREWS INTO BAND LONG TAPCONS 2x P.T. AS REQ'D 2X8 P.T. STAGGERED @ 16" O.C. X I ♦ JOIST & (4) 3/16"x1-3/4" WEDGE 2x DETAIL 2 1/4" DETAIL 2-ROWS INTO MASONRY 3-1 /4" DETAIL t5^ NOTCH WEB AT THE FIRST 2 COURSES ♦ BOLTS INTO K.O. BLOCK BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC LED CELL PER FOUNDATION PLAN FILLED CELL INSTALLATION H RETROFIT FOR MISSING EMBEDDED STRAP SCALE: N.T.S. SS SEE TYP, 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. sCALE.N.T.s. SS 2X8 P.T. BUCK -CONNECT TO BLOCK SECTION UPLIFT CAPACITY = 945 # FOR 1 STRAP W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. A -A =1890 # FOR 2 STRAPS FILL 1st4 COURSES EMBEDMENT INTO BLK.) 1/4" MAX SOLID wiGRouT 2'-0" 8" 1-PLY PRE-ENGINEERED TRUSS d 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. ARCH BLKG. &BUCK 1/4" x 31/4" TAPCONS 1„ 1„ USP RT16M W/ (8) NA11 NAILS & (6) 4 x 24 ..:, BLOCK HEADER TAPCONS 1/2" DRYWALL (IF TRUSS IS 2 PLY INSTALL USP HTWM16 W/ (6) 10d NAILS x *NAILS AND 8d NAILS AT 8" O.C. AT BUCK LEAVE A CUT OUT IN O.S.B. ON THE = .__ (4) X 14 WEDGE BOLTS [ (1) STRAP 1225 # , 2 x 8 451 DIAGONAL (4)10d NAILS INTO BRACE(S) INSIDE TO ALLOW FOR INSULATION ; ._: ::.:';`:-. (2) STRAPS 2450#]) 2 x 8 BRACE/ BLKG. 7/16" OSB TO BE INSTALLED _, BOND BEAM OR CAST FOR OVERHANGS BETWEEN OVER 1 1/2" BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR POLY -CELL IN THIS AREA 2 x 8 45 DIAGONAL BRACE AT EA. IN PLACE BEAM CONTACT ENGINEER OF RECORD FOR FURTHER INSTRUCTIONs. ^ .. ' ;•' : °. •:' SCRIBE (NOTCH) BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 FACE OF ARCH W/ (3)10d NAILS AT EA. END RETROFIT TRUSS DETAIL OVERRAN .��... �... CONNECT W/ 8d NAILS BRACE/ BLKG. . N.T.S. x4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB INSTALL WDW. SCREW ANCHO\_2 ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8\-PROVIDE1MIN.O WITHIN RETROFIT WALL OVERHANG DETAIL (NTS) INTO ARCH BLKG. PER A 4" MIN. OF BRACE BRACE 2 X 4 #2 SYP SCAB TO SIDE OF INSTALLATION DETAILS -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU TRUSS AS SHOWN FOR O.H. UP TO 2'-6" FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" �— 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH * DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. START OF ARC IF TRUSSES USED) W/ (3) #6 X 4%" WOOD NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REO'D. 4' MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY xOV (2)10d NAILS @ 8" O.C. FRyyN TO TRUSS TOP CHORD ARCH DETAIL WALL USE (3)1/4" X 31/2" TAPCONS AT 16" SCALE: N.T.S. SS O.C. 12 + 4FN OTN PLYWOOD SHEATHING + 1 r-0 51-011 JACK TRUSS PROVIDED BY SEE + TRUSS COMPANY OR PLAN 2x6 #2 SYP @ 24" O.C. + + + INISH FLO QJR 2 x 8 BUCK - CONNECT TO BLOCK SECTION + + BLOCKING AS ° - WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. B-B ROOF SHEATHING ATTACHED + REQUIRED > EMBEDMENT INTO 14 MAX K. ) PER NAILING SCHEDULE ALL TO SUPPORT TRUSS e . ° .. #5 BAR BLOCK HEADER SOLID BLKG. AT TOP BTWN. ARCH 2'-0" 8" (5) -12d NAILS + SOFFIT + ' „:° ' ° P ° .� ° D' 1A ° 6 CENTERED W/ BLKG. & BUCK 2X6 TO 2X4 USP RT3A 2X4 SYP r ®s e • .' ° '� 90 IN TOP o 1 X 4 FURRING EACH TRUSS - e • KNOCKOUT / F"4 ° CHAIR BLOCK 8d NAILS @ 8 O.C. AT BUCK PROVIDE 2 x 8 DIAG. BRACE BTWN-, 2 x 8 VERT. W/ (2)10d NAILS AT EA. END PROVIDE (2) MIN. PROVIDE 2x CONT. W/ CONNECTOR s' . MONO FOOTING ' � . ° •� n' ° (3) . SIZE AND REINF. PER PLAN VERT. BRACES WHEN HGT. OF TAPCON AT EA. SIDE 12d NAILS SEE LINTEL -I BRACE EXCEEDS 24" BUCK - (1) WITHIN 4" JACK TRUSS PROVIDED BY SCHED. AND SECTION DETAILS LEAVE A CUT OUT IN O.S.B. ON T MIN. OF START OF TRUSS COMPANY OR 2x4 -� ° ' CLEAN FILL ° 2 x 8 VERT, BRACE(S) INSIDE TO ALLOW FOR INSULATION ARCH #2 SYP @ 24" O.C. ENTER SO IT .o • r DIRT S z TO BE INSTALLED g 100 4'-0" MAX SEE PLANPRECAST BUILT UP PLWD. BUCK - LINTEL , °: ° STANDARD q (NOTCH) SCRIBE NOTCH BACKSIDE 7/16" OSB ARCH PANEL 2X4 SYP #2 CONT. (MATCH TRUSS DEPTH SEE ELEVATION > 90' #5 BAR IN HOOK N TO FIT ARCH CONNECT W/ START OF ARC IF TRUSSES USED W/ 2 #6 X 4%" WOOD ) O FOR OVER HANG FILLED CELL , • -; • -. • -. • - , �L 8d NAILS 2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) 4' MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY (MAX. 4'-0") v _, . L V . N BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL EQUAL WALL USE (2)1/4" X 3112" TAPCONS AT 16" .; INSTALL WDW, SCREW THRU OSB INTO 2 x 8 O.C. .- .• r .• r .• r . • .- .• Sk ANCHOR INTO ARCH BLKG. STEMWALL FOOTING SIZE AND PER INSTALLATION DETAILS B-g ARCH DETAIL K SECTION @ ENTRY L SECTION @ ROOF EXTENSION M REINF. PERLAN AND STEMWALL SCALE: N.T.S. SS SCALE: 3/4" =1'-0" SS SCALE: 314" =1'-0" SS MONO TO STEMWALL FOOTING SECTION DETAILS SCALE: 3/4" =1'-0" GLASS BLOCK INSTALLATION NOTES NOTE: IF RETROFIT FILLED CELL CONDITIONS A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY EXCEED (3) PER PROJECT, CONTACT ENGINEER OF RECORD AT LEAST 2 HOURS BEFORE PLACING MORTAR. B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP FOR ADDITIONAL INSTRUCTION. EXTENDS TO SILL. C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. MASONRY WALL. SEE PLAN FOR EXISTING BOND BEAM. REINFORCING. PROVIDE LOWER D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS HOOKED DOWEL 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE SEE SHEET D2 AND DRILL 3N MIN. HOLE TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP FLOOR PLAN FOR A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL MORE INFO SET BARR IN E EPDXY REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR HTT16 W/ (18) -16d NAILS TO CAP TO PREVENT LEAKAGE BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER W.W.M. AT PERIMETER COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. 1/4" EXPANSION BOLT (2 WHERE THIS CONDITION STUDS & (1) - 5/8" DIA. ALL #5X6' EMBEDDED INTO E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 ga. PANEL PER ANCHOR) (1) #5 BARS CONT. OCCURS TOP WITH MIN. 3" THREAD ROD EPDXIED W/ SIMPSON "SET' EPDXY MIN. } z EXISTING BOND BEAM IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. THE SAME SPACING ( REINFORCING COVER „ 6 � 5" EMBEDMENT & 3" MIN. ` O SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER -0 F F EDGE DISTANCE FILL CELL FULL HEIGHT W/ OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE COURSE) EXPANSION STRIP LL w NON SHRINK GROUT. THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL :. ° _� o u ��—x p � 0 9 w a A REINFORCING AS FOLLOWS: * .=:-`' SEALANT V U 1 PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW.►- T.,;.:�'•" r:::' -'-r � * PRESS PANEL REINFORCING INTO PLACE. — � I- U z 6'EMBEDDED INTO tM1 6" MIN. LAP SPLICE WI _ - I EXISTING FOOTING 2-#5X61 CONC. N NC INF COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR D D TROWEL H A BE AN REINFORCING PANEL ;r:;..' :,": " • � Q a cn � FILLED CELL SMOOTH. DO NO FURROW. s :`<,;''`'•..:... ' p.° N DRILL 3/4"X6" MIN. HOLE F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING -DO NOT FURROW, MAINTAIN UNIFORM JOINT WIDTH. '�`'" `' `" " r;.:...c,;..`.:;::: 6" MIN. LAP GRADE �. p •' n `. SET BAR IN EPDXY G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST ' ° SPLICE C11 ° :Q REMAIN FREE OF MORTAR. NOTE: M f I \ H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS SEE GLASS BLOCK INSTALLATION NOTES. r o ` TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT ° ° \_a ;4" SAW CUT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL o (2) #5 REBAR. MIN. 3„ TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 16" MIN. 01COVER EA. WAY A SECTION 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN Aq EXISTING FOOTING GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. 1 SCALE: N.T.S. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE SECTION AT DEEP MONO FOUNDATION RETROFIT FOR MISSING MSTAM STRAP MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. RETROFIT FILLED CELL DETAIL K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. = SCALE: 3/4"-1-0" = , n SCALE: 3/4"-1-0 FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR SCALE: N.T.S. INSTALLATION OF GLASS BLOCK. U� z o OZ � z� Q J tZ O Ln (D VJ cn ) 'I--J w _m 0 "U — 0 W C o M c1 i (6 U o 0 CO N M LL I— 0 U C ai M N 0 20 2 ai �u.m Y (n . 0 O Q0 Qo A ' s D® N C B DC to . U) m..IU LLj Q r 5 � L Ul LL Q� �N°4i�...a•°eC� jai E]Oe� llell<I� To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z 1714 0 N I-, 1-, 4-J O -4 M O ro �'- 01 Q(3) Lrn oC U ra Z E WJ � C)Z uo z d <Q IaS¢�� zgo z2W; is=z2 J 8W N �Wo 088 ZZ ><O xz z -a N V� cv Lf) 0 N > rq 0 o U U J o X 0 Q se U,2 0 - _ LJJ .0 o¢oa r� ¢ �a.• 0 Q W� z N U4ago C J .Lr)-I w LLJ H o 0� O ¢ W�- ;.o 00 ¢ z z = Z a N m N ZJo _ Z ¢Z r-I 0. (n SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO. 10 SHEET NO. SS i CROSS BRACING DETAIL (TYP.) SCALE: 1/2" = 1'-0" TRUSS NOTES: FRAMED RIDGE CONYBE . 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2002 MAY NAILED (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS—� COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" O.C. MAXIMUM. 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D NAILS AT EACH TRUSS INTERSECTION. 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS 2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING MAX & EACH END ALTERNATE BETWEEN EA. TRUSS DIRECTION TYP. `---LWOOD TRUSS - A TYP. WOOD TRUSS BLOCKING DETAIL SCALE: 1/2"=V-0" CB TYP. HAND FRAMING ABOVE TRUSS 2X4 STUDS & PLATES AT 2'-0" O.C. EACH DIRECTION TYP. U.N.O.—� 2x8 BLKING. NAILED @ EACH SIDE w/ (3) 12d NAILS WHEN REQUIRED w/ (2) USP HTW20 W/ (14) -10d X 1 1/2" EACH TB 7 PRE-ENG. TRUSS I CONT. ROOF SHEATHING AT TRUSS TOP — CHORD AT ALL HAND FRAMED AREAS TYP. DIAGONAL - AT 8'-0" MAX 2X4 CONT. AT T & B CHORD TRUSS ROOF PLEAEN SHEATHING 2X4 BLOCKING BETWEEN TRUSSES SECT. A -A PROVIDE 2X4 MIN. BLOCKING AT Q OF HIP/RIDGE, TYP.BETWEEN TRUSSES W/ (2) 12D NAILS EACH END TO TRUSS TOP CHORD TYP. �7A TRUSS G.T. ADD 2X4 ALONGSIDE TOP CHORD WHEN REQ'D TO PREVENT PLYWOOD SPAN FROM EXCEEDINGJACK MAX 24" SPAN (EITHER USSES HIP SIDE OR BOTH IF REQ'D) G.T (2) 12D NAILS — AT 12" O.C. MAX HIP/RIDGE BLOCKING DETAIL VERTICAL SCAB 2 x 6 #2 SPF 48" O.C. W/ (4) 10d TOP & BOTTOM OR USP RT7 OR HCLR/LL W/ 8 - 8d IN PLACE OF (4) 10d COLLAR TIE EVERY 3rd RAFTER 2X4 SPF 2 (2) #7X 3-1/2" WOOD SCREW EACH TRUSS OR USP RT7 @ 48" O.C. BEVEL CUTS (OPTIONAL) 2x8 #2 SPF RIDGE BEAM 2x6 #2 SYP RAFTERS FOR SPANS 4FT TO 8FT 2X4 RAFTERS FOR SPANS LESS THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d COMMON TOENAILS TO RIDE BEAM CONC. MASONRY STEEL OR WOOD BEARING SUPPORT A -A ALTERNATE BLOCKING DETAIL @ INTERIOR BEARING 3 SCALE: 1/2" = l'-0" PROVIDE BLOCKING AT ALL TRUSS BEARING SUPPORT WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT USP LSTA18 CENTERED @ SPLIT TO TIE BEAMS TOGETHER SEE FLOOR PLAN FOR COLUMN SIZI & ADDITIONAL INFI SCALE: 1/2"=V-0" USP HD4101F BUCK -- SEE ROOF PLAN FI MORE IN (2) 2x8 #2 SYP W 7/16" O.S.B. FLIT PLATE TOP @ TI BRG. TYPIC WALL NOTE: PENDING BEAM BEARING LOCATION, THE BEAM CAN SIT ON TOP OF COLUMN W/ (2) HTW20 STRAPS _J USP JUS46 OR JUS461F BUCKET TO COLUMN SUPPORT COLUMN BUILT-UP (2)-2x4's OR 4x4 W/ (2)-10d NAILS @ 8" O.C. EACH PLY (SHOWN AS 4 x 4) (2) USP HTA20's w/(10)-10d x 1 112 EA. TO COL. ALT: (2) USP MSTAM36 STRAPS CENTERED w/(13)-10d NAILS Ea TO COL. TIE BEAM BEAM @ RAISED ENTRY MASONRY WALL 4 SCALE: 1/2" = 1'-0" L.SEE PLAN I. FOR CANT. SEE FLOOR PLAN FOR COLUMN SIZE & BASE 7/16" OSB FLITCH PLATE CONNECTION INFO REQ'D ONLY WHEN INDICATED ON BM. 7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR SCHEDULE/PLAN REQ'D ONLY WHEN COLUMN SIZE & BASE OPTION A INDICATED ON SCHEDULE/PLANM OPTION B CONNECTION INFO OPTION C COMMON BM. TO POST ATTACHMENT SEE ROOF PLAN FOR BEAM SIZE & CONNECTION INFO. USP ST18 TYP. U.N.O. SEE FLOOR PLAN FOR COLUMN SIZE & ADDITIONAL INFO. (WOOD COLUMN SHOWN) A F_� A SEE PLAN FOR SEE PLAN FOR CANT. IF INDICATED SEE FOUNDATION PLAN FOR MORE INFO 5" COMMON BM. ATTACHMENT SCALE: 3/4"=V-0" SCALE: 3/4"=V-0" jp BM. SPLICE OVER CL /, CENTER OF POST MIDDLE EXTERIOR ATTACHED SCHEDULE JACK TRUSS (AS SHOWN) OR GABLE END SEE TRUSS LAYOUT CLIP EACH TRUSS (SEE ROOF PLAN FOR TYPE) FRAME OUT TO BLOCK EDGE SEE DETAIL 4/D1 FOR BEAM SIZE 2x SPF #2 AT 16" O.C. BUILDER FRAME RADIUS AS REQUIRED KNEEWALL @ENTRY FRONT WALL 2X4 #2 SYP NAILER. NAIL - TO STUDS w/3-16d @ EA. STUD. TOENAIL EA. TRUSS TO NAILER w/3-10d USP JU26 OR IF 2 PLY ---' TRUSS USP JUS26-2 TRUSS TO LEDGER 2X8 #2 SYP CONT. LEDGER W/ (4) 16d NAILS ATTACH NAILS INTO END OF EACH FLOOR TRUSS, 24" O.C. MAX. (AT EACH SIDE OF G.T. INSTALL (4) NAILS EACH SIDE) SCALE: 1/2" = 1'-0" ROOF AND EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE SEE 2ND FLOOR WALL SECTION FOR ADDITIONAL INFORMATION SEE FLOOR FRAMING PLAN AND J/S6 FOR MORE INFO. VERIFY WITH PLAN FOR LOCATION AND DIRECTION (IF PARALLE SEE 2/D2 FOR BLOCKING INFO) -MASONRY WALL (TYPICAL) SECTION AT LOW ROOF SCALE: 1/2" = V-0" r, VARIES 2x STUDS @ 16" O.C. IT X ROOF SHEATHING SEE 1/S5 FOR SEE PLAN FOR W/ USP SPT22 @ ATTACHED PER ADDITIONAL 8d NAILS AT VALLEY TRUSS BASE & SPT24 @ TOP 2X4 #2 SPF BRACING @ NAILING SCHEDULE EXTERIOR SHEATHING OUTLOOKER INFO. 4" O.C. INFO. 2x BLOCKING BETWEEN 16" O.C. W/ (4) 12d COMMON TRUSSES. ATTACHED PER STUDS TO TRUSS W/ (2) TOENAILS TO TOP SEE TRUSS PLAN 2X4 STUDS W/ USP NAILING SCHEDULE 12d TOENAILS EACH END PLATE & (2)12d END MIN. (2) 2x4 FOR CONNECTION SPT22 @ BASE SEE BETWEEN TRUSSES 2 STRUCTURAL SHEATHING NAILS TO TRUSS SPF TOP INFORMATION. J/S6 FOR MORE GABL 12d NAILS TO EACH ATTACHED PER NAILING BOTTOM CHORD PLATE INFO. TRUSS LOW ROOFNVALL VERTICAL STUD) SCHEDULE SHEATHING ATTACHED PER NAILING SCHEDULE 2x BASE PLATE W/ (2) 12d VARIES W/ VARIES SEE PLAN FOR WALL LOCATION 2x4 BASE PLATE W/ 1/2" PLYWOOD NAILS @ 16" O.C. ALONG W/ USP MTW12 TO BLOCKING ROOF SLOPE USP LSTA30 OR MTW12 TO FLOOR (2) 16d NAILS TO BELOW @ 16" O.C. WOOD WALL GIRDER BELOW @ 16" EACH COMMON OR TRUSS. 2X4 CONT. W/ (2) MIN. 2X4 #2 SPF STUDS @ O.C. TYP TOP BOTRUSSI IOM34 SEE PLAN 16d COMMONS 16" O.C. W/ EXTERIOR NAILS EACH SHEATHING ATTACHED a xx STUD TYP. T&B PER NAILING SCHEDULE & -MASONRY WALL BELOW: USP PLYWOOD (3) 12d TOENAILS TO a<. HTA16 @ 4'-0" O.C. TO GABLE FLOORING TRUSS OR SEE PLAN FOR PLATE BELOW MASONRY WALL TRUSS BEAM BELOW: USP ROOF SYSTEM TOP OF WALL OR BEAM HTW20 @ 4'-0" O.C. TO GABLE MIN. 2x4 #2 SYP P.T. PLATE 16" FLOOR SYSTEM FLOOR GIRDER SEE TRUSS PLAN a, TRUSS k W/ 1/2"X8" EPDXY ANCHOR SEE PLAN FOR SEE PLAN FOR a COMMON TRUSS LOW ROOF TRUSS W/ (2) 2x6 BLOCKING UNDER FLOOR G.T. MASONRY WALL SEE @ 3" FROM EACH END & DIRECTION CONNECTION SEE ROOF RAISED BOTTOM CHORD 2nd FLOOR WALL W/ USP SEE PLAN PLAN FOR MORE 16" O.C. MAX. OR CONNECTION EXTENSION SEE TRUSS JUS24-2 EACH END SHEAR TRANSFER INFO. SECTION @FLOOR CONNECTIONS TO G.T. EXTERIOR. WALL SECTION ENTRY s CONNECTION 22 SECTION AT HIP GABLE 12 SECTION BUMP OUT 39 SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" SCALE: 3/4" = V-0" SCALE: 3/4" = 1'4' SCALE: 3/4"=V-0" DETAILS & SECTIONS U z o z° z� Q 0- z cnn/�,, U W cn -I--J w (6 0 �U — O LU E (A(D-Of (0 N omo U m� a)M LUc'm� F_ 8 O o N = N U-00 tIC 00 ca a) Y `�CL0 V7 O d' Q CD Q O Al BD. N'C�B -DC vx111T11 � �o%%,1111111 QW N v •�. (As a o U_ COO ujJ C lL > { c �w LL A Z: Y,R y A C Qd'_t rriJyi O ��dJ�•91t I Ilo\ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential, Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O 0 Z O�I� �>-+HMO Q �Ln _ O' L n Q LL Ln CL .-s ce U Q. 00 z ... ry W O W J� 'd- 0,z �5i W0 z a z U zUZt �:,zz J Lu Lu N zoho zz Ln O Qo xZ I— ro Ln W U) S O O J z V (n J u, W o ¢ F? O O , ���� N I\ 0 Z¢oa J Lu z Z N Ln a b tll J r-I LU =Q� o z 8O � Q Q Z Lu 8 < z 00 N z z aU) Z0 O S = ¢z uj SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 SHEET NO. D1 (2)- 12d GABLE END FLOOR SEE SS FOR RETROFIT (1) USP LSTA30 STRAPS BENT OVER TOP PLATE TOENAILS 2x4 TO TRUSS TOP TRUSS SEE R/S6 FOR CONNECTION IF MSTAM36 CAN NOT BE INSTALLED / 1 OR 2 PLY GIRDER THEN DOWN THE FACE USP SPT4 W/ 6 10d X 1 1/2" ( ) CONNECTION INFO TO TRUSS. SEE PLAN FOR OF HEADER/STUDS W/ @ 24" O.C. MASONRY WALL CONNECTION. (22) 10d NAILS EXT. SHEATHING QA BELOW AND ALT. SEE PLAN FOR CONN. (2) - 2x SPF TOP PLATE FLUSH W/ TOP BLOCKING INFO Q 2x CRIPPLES @ 16" O.C. (2) 2x HEADER SEE PLAN SEE FOR 2 OF MASOORY& 8d BLOCKING NAILS T/B FLANGE 0 1. APPLY SUB (3) 2x # SPF W/ (2) 12d TOENAILS T/B INTERIOR HEADER DETAILS '� FLOOR + STUDS w/ 10d @ (2) - 2x SPF TOP PLATE (2) 10d TOENAILS AT EA. (1) 2x SILL PLATE W/ (2) 12dTOENAILS. 2x STUDS © ADHESIVE TO 8" O.C. EACH SIDE END SILL. MAX. EXTERIOR HEADERS • Zx4 CONTACT SURFACE 0 2x4 #2 BLOCKING U.N.O. ON PLAN OPENING WIDTH 4 FEET, I (1) 2x SILL PLATE W/ (2) 12d TOENAILS. o IF OPENING IS GREATER OPENING LARGER THAN 4 ft (2) 2x FLOOR SYSTEM SEE PLAN MNOTE: VERIFY WITH FLOOR FRAMING PLAN FOR I -JOIST B 2x4 SIDE BRACE AT 48" O.C. THAN 4 FEET BUT NOT EXCEEDING 6 FEET. SILL PLATE W/ MP3 CLIPS EACH SIDE OR FLOOR TRUSS FOR BETWEEN JOISTS 2X CONT. RIBBON A MP3 CLIP IS TO BE MIN (3) 2x #2 SPF STUDS @ END CORRECT BLOCKING w/ (3) 12d EA. END INSTALLED AT EA. END OF HEADER SEE Q/S4 FOR REQ'D ° G.C. VERIFY INTERIOR REQUIREMENTS TO HORIZ. TYPICAL BLOCK FLOOR DECK JAMB INFO 1/2" GYP. BOARD OR BLOCKING WALL 2x CRIPPLE AT EA. USP LSTA 30 w/ 11) - 10d (2) USP MSTAM36 STRAPS w/ (8) 10d EXTERIOR STRUCTURAL 1-1/8" RIM BOARD END OF OPENING TO STUDS ABOVE PLATE NAILS & (5) Ya" x 2 TAPCONS SHEATHING (MIN. 7/16") FLOOR TRUSS/ NAILED TO STUD CENTERED ON FLOOR SYSTEMSTEMTTO °' '` VERIFY W/ PLAN 8d NAILS @ 3" O.C. JOIST SEE PLAN (2) USP MSTAM36 STRAP(S) I -JOIST SEE PLAN PACK w/10d NAILS FLOOR DECK MASONRY WALL BELOW. CONTRACTOR WALL SHEATHING (2) - 12d TOE NAILS TOP CENTERED W/ (8) 10d NAILS TIE BEAM @ 8��° c FLOOR TRUSS/ I -JOIST SEE PLAN MAY USE (2) SIMPSON MSTAM36 STRAPS TO RIM BOARD & BOTT. CHORD & (5) 1/4 TAPCONS. USP LSTA30 FROM WINDOW w/ (7) 10d NAILS & (4) Y4' x 2 Y4' TITENS AJS BLOCKING PANEL @ 24" CONTRACTOR MAY USE JAMB TO FLOOR TRUSS/ SOLID INSTEAD OF USP MSTAM36 STRAPS. IF SCALE:1 112" =1'-0" O.C. (MAX) AND @EACH SIMPSON (2) MSTAM36 W/ (7) PROVIDE BLOCKING BLOCKING BELOW. BELOW USE (2) MST WOOD WALL IS BMSTA36 SCALE:3/4" =1' - 0" GABLE END RIM JOIST END OF WALL UNDER 10d NAILS & (4) Y4'I TAPCONS BELOW JAMBS SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE STRAPS (22) 10d NAILS (2) SEE SS FOR RETROFIT SEE R/S6 FOR CORNERS INSTEAD OF USP STRAP. FOLLOWED IF DOWN SET OR BOX HEADER IS USED SIMPSON MSTA36 STRAPS w/ (26) 10d CONNECTION IF MSTAM36 CONNECTION INFO TO - 10d TOE NAILS EITHER STRAP IS ADEQUATE OTHERWISE DETAIL CAN BE IGNORED NAILS (G.C. TO INSURE SOLID BLOCKING SECTION CORNER CAN NOT BE INSTALLED MASONRY WALL EACH SIDE E IS INSTALLED), EITHER USP OR SIMPSON STRAPS ARE ADEQUATE FRAMING ATTACHMENT BLOCKING DETAIL r2 GIRDER/COL. CONN. @ 2nd FLOOR 3 HEADER CONN. @ 2nd FLOOR 4 SCALE: 1/2" = V-0" AS NOTED SCALE: 3/4" = V-0" SCALE: 1/2" = V-0" Kz:�) SEE Q/S4 FOR O USP SPT24 @ EA. STUD W/6-10d SEE SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED 2x6 / 2x8 CRIPPLES @ 16" O.C. TOP OSEE JAMB STUDUSP SPT4 W/ (6)-10d X 1 1/2" TO STUD & TO TOP PLATE NOTCHED @HEADER LOCATION SEE REQ'D TYP @ 24" O.C. O USP LSTA24 W/(18)-10d NAILS CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED INFO BELOW ON CONNECTION OF P2LATE PLAN o°o o°o o.°o 00o CRIPPLES IF LONGER THAN 8" TALL. P. 2 - 2 x 4 SPF O USP RS150 W/ MIN. 12" END USP SPT4 W/ (6)-10d X 1 1/2" SEE PLAN FOR CONN. (CONTRACTOR MAY USE RTT CLIPS) NAIL BACK LEG OF CIPPLE TO (2) 2x HEADER TO SIT A TOP PLATES LENGTH ON STUDS W/ (11) 10d (1) USP LSTA30 STRAPS BENT OVER TOP PLATE THEN DOWN @ 24" O.C. HEADER w/ (2) 12 TONEAILS FLUSH w/ THE OUTSIDE NAILS TO STUDS ABOVE & (11) 10d NAILS TO STUDS BELOW. THE FACE OF HEADER/ STUDS (2) - 2X SPF TOP PLATE SEE PLAN FOR SIZE 2 x 4 #2 SPF STUDS W/ (22) 10d NAILS (2) 2x HEADER SEE PLAN 2x6 / 2x8 WALL BEYOND SEE C AT 16" O.C. U.N.O. OD USP SPT22 W/ (6)-10d TO STUD & NAILING AREA (TYP.) HEADER FLUSH TO OUTSIDE FLOOR PLAN FOR HEADER (2) 2x HEADER G (4) - 10d TO PLATE E 5/8" A.B. @ 24" O.C. AND 6" FROM O MIN (3) 2x #2 SPF STUDS @ INTERIOR HEADER SEE PLAN FOR COL. SIZE CONNECTION SEE PLAN ( °' END OF HEADER SEE Q/54 FOR 2x SILL PLATE W/ 12dTOENAILS. (2) USP MSTA36 STRAPS CENTERED SEE STANDARD HEADER EACH END W/ 7" EMBEDMENT. IF (1) (2) w/ (22) 1d NAILS OR (2) SIMPSON DOUBLE 2x6 OR 2x8 TOP CONNECTION DETAILS FOR AT STEP DOWN LOCATION, MIN 7" REQ'D JAMB INFO EXTERIOR HEADERS MSTA36 STRAPS w/ (26) 10d NAILS PLATE SEE PLAN MORE INFORMATION 2 x SPF EMBEDMENT PAST STEP. (1) 2x SILL PLATE W/ (2) 12d TOENAILS. FLOOR SYSTEM OR SIMPSON STRAPS NAILS, BASE PLATE O USP SPT4 EACH STUD 2x CRIPPLES @ 16" O.C. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/MP3 CLIPS EACH SIDE 2-STY. FRAMING ARE ADEQUATE) O.C. PP TA& B USP SPT6 OR C B B • C H PRE-ENGINEERED @HEADER /JAMB CONDITION FLOOR SYSTEM OR IF BUILT-UP STUDS ARE W/ (2) 12d TOENAILS T/B (2) - 10d TOENAILS AT EACH END OF BAND JOIST & BLKG. (2) 2 x #2 KNEEWALL OR BEAM W/IN WALL SYSTEM A.B. TO BE SILL (MAX. OPENING WIDTH 4 OR LVL GIRDER SYP U.N.O. SPACED W/IN 6" FROM OPENINGS (2) - 2 x 4 SPF 2X CRIPPLE AT EACH END OF FEET). IF OPENING IS GREATER (BLOCK SOLID) AND MULTIPLE STUD PACKS TOP PLATES OPENING NAILED TO STUD THAN 4 FEET, BUT NOT EXCEEDING 6 FEET, A MP3 CLIP IS TO BE SEE PLAN FOR 2 x CONT. T & B OINTERIOR HEADER PACK W/ 10d NAILS @ 8"O.C' INSTALLED TO EACH END COL. SIZE (1) 2x SILL PLATE W/ (2) 12dTOENAILS. UjU 2 x 4 #2 SPF STUDS B EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2)12d TOENAILS. TYPICAL BLOCK WALL PLYWOOD ATTACHED PER NAILING SCHEDULE USP HTT45 BASE W/ AT 16" O.C. U.N.O. (2) 2x HEADER G OPENING LARGER THAN 4 ft (2) 2x SILL FLOOR TRUSS/ I -JOIST SEE PLAN AN NAILS & 1 ANCHHOO R BOLT W/ BOX HEADER SEE PLAN F F PLATE W/ MP3 CLIPS EACH SIDE 2 x 4 P.T. HH STUDS UNDER 2nd FLOOR HEADER USP MSTAM36 STRAP(S) CENTERED W/ (8) 10d NAILS TIE BEAM \ V. MIN. 6" EMBEDMENT (2) LSTA12 WRAPPED UP (2) 2x TOP PLATE D BASE PLATE ARE NOT REQ'D TO HAVE & (5) 1/4 TAPCONS. AND OVER TOP PLATE „ rl o°� CONTRACTOR MAY USE PROVIDE BLOCKING �� 2x CRIPPLES @ 16 O.C. W/ USP SEE FOUND. PLAN FOR FTG. REQ. CONNECTIONS. ATTACH STUDS w/ (3) 12d TOENAILS T&B SIMPSON MSTAM36 W/ (7) BELOW JAMBS a ° ° SPT22 &SPT24 (OR SPT4) CONNECTORS 10d NAILS & (4) Ya"x2Ya" • • ' @TOP PROVIDE EXTERIOR SHEATHING 2 ST. I NT. BEARING WALL ATTACHED PER NAILING SCHEDULE TAPCONS INSTEAD OF USP STRAP. EITHER STRAP IS ADEQUATE SEE FOUNDATION PLAN FOR FTG. REQ. 2x CRIPPLES TO PROVIDE 2 CRIPPLES BELOW () TO ANY GIRDER TRUSS IN THIS SITUATION. CONNECT G.T. TO FOR EXTERIOR 2 STORY WALLS ONLY. MATCH JACK STUDS W/ (2) - HTW20 TOP & (2) AND EXTERIOR SHEATHING CAN STOP ONCE UNDER rj HEADER CONN. 2nd FLOOR @ STUDS BELOW BASE DHAN LOWER ROOF. 6 2 STORY COL. @GIRDER (IF CR PLLES ARELESS SCALE: 1/2" = 1'-0" SYSTEM 42 SCALE: 1/2" = V-0" � 8" LONG NO STRAPS ARE REQ'D) SCALE: 1/2" = 1'-0" ADDITIONAL STRAPS SEE STANDARD HEADER REQUIRED AT TOP PLATE CONNECTION DETAILS FOR TO STUDS TO MATCH MORE INFORMATION HEADER STRAPS SEE SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED (2) LSTA24 (2) 2x HEADER SEE PLAN SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE FOLLOWED IF DOWN SET OR BOX HEADER IS USED (2) USP LSTA30 STRAPS USP SPT4 W/ (6)-10d X 1 1/2" 2x4 STUDS PER PLAN MIN (3) 2x #2 SPF STUDS @ END OF HEADER OTHERWISE DETAIL CAN BE IGNORED BENT OVER TOP PLATE @ 24 O.C. SEE Q/S4 FOR REQ'D JAMB INFO THEN DOWN THE FACE OF (2) 2x HEADER SEE PLAN USP MP3 EACH END TYP. FOR OPENINGS LESS THAN 4'-0" WIDE, HEADER/STUDS W/ (22) 10d DOUBLE 2x4 (1) USP LSTA30 STRAPS BENT NAILS 2x CRIPPLES @ 16" O.C. TOP PLATE SILL MAY BE ATTACHED W/ (2) 16d OVER TOP PLATE THEN DOWN USP SPT4 W/ 6 10d X 1 1/2" ()- W/ (2) 12d TOENAILS T/B TOENAILS @ EACH END THE FACE OF HEADER/ STUDS @ 24" O.C. INTERIOR HEADER ° 2 WS 10d @ (2) 2x SILL PLATE W/ (22) 10d NAILS (2) - 2X SPF TOP PLATE 2x HEADER SEE PLAN MIN (3) 2x #2 SPF STUDS (1) 2x SILL PLATE W/ (2) 12dTOENAILS. EXTERIOR HEADERS 3" 0/C �2xST�UDS 2x CRIPPLES 16" (2) @ END OF HEADER. SEE 2x SILL PLATE W/ 12d TOENAILS. ° �48k4 @ 16" O.C. @ O.C. W/ (2) 12d TOENAILS T/B INTERIOR HEADER Q/S4 FOR REQ'D JAMB (1) (2) OPENING LARGER THAN 4 ft (2) 2x T TOP SPLICE ti!/N Op (1) 2x SILL PLATE W/ (2) 12dTOENAILS. INFO. EXTERIOR HEADERS SILL PLATE W/ MP3 CLIPS EACH SIDE ° (2) - 10d TOENAILS AT EACH END OF SILL (MAX. OPENING (1) 2x SILL PLATE W/ (2) 12d TOENAILS. THAN 4 2x CRIPPLE AT EACH END OF OPENING NAILED TO STUD (2) - 10d TOENAILS AT EACH END OF SILL (MAX. OPENING WIDTH 4 FEET). ° ALT. HEADER ANCHOR WIDTH 4 FEET). IF OPENING OPENING LARGER ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE PACK W/ 10d NAILS IF OPENING IS GREATER THAN 4, H IS GREATER THAN 4 FEET FEET BUT NOT EXCEEDING 6 FEET, ° SCALE: N.T.S. BUT NOT EXCEEDING 6 FEET, MIN (3) 2x #2 SPF STUDS @ END TYPICAL BLOCK WALL A MP3 CLIP IS TO BE INSTALLED AT PROVIDE 2x4 ON ° A MP3 CLIP IS TO BE INSTALLED AT EACH END OF HEADER SEE Q/S4 FOR EACH END. FLOOR DECK TOP OF 2x8 TO ° REQ'D JAMB INFO BLOCK OUT TOP 2x CRIPPLE AT EACH USP LSTA30 CENTERED (2) USP MSTAM36 STRAP(S) FLOOR TRUSS/ I -JOIST SEE PLAN •• PLATE ATTACH END OF OPENING NAILED TO STUD PACK W/(22) 10d NAILS CENTERED W/ 8 10d NAILS () 2X CONT. RIBBON W/2d NAILS @ 3,O.C. W/ 10d NAILS @ $ o.c. I FLOOR DECK & (5) 1/4 TAPCONS. TIE BEAM 2x4 BEYOND AGAINST 2x8 DOUBLE CONTRACTOR MAY USE 2x8 TOP FLOOR TRUSS/ I -JOIST SEE PLAN SIMPSON (2) MSTAM36 W/ (7) PROVIDE BLOCKING STUDS PLATE SEE PLAN FOR BEAM 10d NAILS & (4) Ya"x2Y4' BELOW JAMBS 2x8 STUDS 2x4 W/ 2 ROWS SIZE & CONNECTIONS TAPCONS INSTEAD OF USP NOTE: PER PLAN OF 10d NAILS STRAP. EITHER STRAP IS PLATE LENGTHS MUST BE @ 3" O.C. HEADER CONN. 2nd FLOOR ADEQUATE N HEADER CONN. @ 2nd AT LEAST 4'1 LONG. TYPICAL W/ HIGH BM FLOOR [DOUBLE STRAP] TOP PLATE SPLICE DETAIL s 10 11 SCALE: 1/2" = V-0" SYSTEM 42 SCALE: 1/2" = V-0" SCALE: 3/4" = V-0" (D r z _o (0 z° z� Q O J a t� z U Q) cn .N w r O"I ~ o Mo Vi o U mI Nm L IJ F-- E — 8 RIM C CIO M N 2 R O o0 = a; , U� �Lco �Qo f Y Q rn � O 6<o B D. � GV io IN rr IS ZwW;ica� LL tilE tain tZ• - e: . ,CC O o Z'0 E cp' E. Q • • LL � �' 41/ Q rn� W Ite>� Esst To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 11 Z NO OWN •:3 I'D O 0 r> ro Ln a rY U 00 O z Q z Z W J�~ d' oZ W� za r a, tjE30 Z zw w � = 0 w Z J KLu J W � p Cis Cq 8 ZZZ O , zz f L to S oN N Jz U W Q W� Q Y�¢a—• rl'� T WU1'CO-+ �y Q LLI ego $ago Z (V N ffoz J Ln LLJ ¢ Q z 8 Z o W az O �o 00 Z :3 CY V1 Z m rn N ^ Z g LV = 2 ¢z uj ,-+ a V) SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO' 10 SHEET N0. D2 0 " WEATHER RESISITIVE BARRIER HEAD FLASHING TIE-IN INSTRUXTIONS: 1. Cut, fold up & temporarily secure weat THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing installation MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under AND WATERPROOFING METHODS TO weather resistive barrier BE USED. 3. Fold weather resistive barrier back over head flashing and seal with tape SELF -ADHERED FLASHING Scale: NTS FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER EXTERIOR SHEATHING REFER TO TECHNICAL LETTER ON CHEMICAL COMPATIBILITY SELF -ADHERED FLASHING DO NOT FLASH OVER BOTTOM NAILING FLANGE NOT USED NAILING FLANGE SELF -ADHERED FLASHING HALF ROUND WINDOW r�r-��rnrvu r�n.�r�nv� SELF -ADHERED FLASHING DECK JOIST 'VVtHINtK ✓E BARRIER & IARILY SECURE EXTERIOR SHEATHING WOOD FRAME CONSTR. SELF -ADHERED FLASHIN BY LAPPING DOWN -� OVER RIM JOIST AND UP WALL BY 6 IN. WEATHER RESISITIVE BARRIER SEAL TOPS OF JOIE UNDER DECKING ED FLASHING (SEE DETAIL WP07) 8 z WEATHER RESISTIVE BARRIER DOOR ROUGH OPENING 3/4%1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING A- SELF -ADHERED FLASHING SUBFLOOR SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING 3/4%1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SECTION -A (SEE DETAIL SELF -ADHERED FLASHING E AM 0 SELF -ADHERED FLASHING SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) SELF-ADHER O SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK SELF -ADHERED FLASHING OUTSIDE CORNER NOT USED RIM JOIST INSTALL SELF -ADHERED FLASHING JAMB & HEAD FLASHING, SEE FLANGED WINDOW (SEE DETAIL WP01) SELF -ADHERED FLASHING, EXTEND A MINIMUM 6" VERTICALLY FROM BOTTOM OF THRESHOLD SELF -ADHERED FLASHING PATCH HERED FLASHING 0 0 0 0 WINDOW UNIT SLOPE 0.3 in: 12.0 in (0.6 cm: 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT. FIN. BUILDING PAPER r - WIRE LATH SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF NEEDED IN CORNERS THROUGH SELF -ADHERED FLASHING -7 0 0 O RUBBERIZED RUBBERIZED ASPHALT ASPHALT ADHESIVE ADHESIVE - -\. SELF -ADHERED FLASHING J1 SCORED RELEASE PAPER (BEFORE FOLDING, SCORE RELEASE PAPER TO EXPOSE ADHESIVE AS SHOWN) SELF -ADHERED FLASHING INSIDE CORNER Ground FOUNDATION WEEP SCREED NOT USED Water Resistant Barrier Lath Sheathing _ Stucco FLASHING REQUIREMENTS R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1 Exception: Omission of the water -resistive barrier is permitted in the following situations: 1. In detached accessory buildings. 2. Under exterior wall finish materials as permitted in Table R703.4 3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following or other approved method: 1.1 The fenestration manufacturer's written flashing instructions. 1.2 The flashing manufacturer's written installation instructions. 1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. 1.4 In accordance with the flashing method of a registered design professional 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. 3. Under and at the ends of masonry, wood or metal copings and sills. 4. Continuously above all projecting wood trim. 5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6. At wall and roof intersections. 7. At built-in gutters. R703.6.2.1 Weep Screeds A Minimum 0.019-Inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. SELF -ADHERED FLASHING PRODUCTS DETAILS TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 Detail Instructions Refer to the number marked as in each detail that corresponds to the numbered items in the list of instructions below: 1. Install self -adhered flashing in order as shown by numbers 2. Install flashing and weather resistive barrier to form water shedding laps 3. Self -adhered flashing can be substituted for building paper 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation and to minimize scoring cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner 8. Mechanically fasten as necessary Cement Plaster in accordance with ASTMC926 over wood 2nd floor 7/8" Cement Plaster in accordance with ASTMC926 WEEP SCREED DETAIL SCALE: NOT TO SCALE 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper 7/16" O.S.B. sheathing Stampede or similar cauk bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish -All inside and outside corner will need to be miter cut and caulked all butt joints need to becaulked using Stampede or sim. caulk for all 0La Z to - o Zto Q a) J CL Q) cn -I--' Lu i'6 p U - O Lu o co 0p O mI— LV N M O7 f1S M I- E - v N -0 cm O o0 aa) Ua�i w L` co Ly U)Q-o to oV 5) 6 -� O 1 N C�B-D•C a f ® O N R N V c,- o° r 'U", 00 Z d Z �M�z iL ocQ.3LL o oW� z W 0) N M N D LL o ul CL w� V ¢ & 10 Z O o cn o7 � Z m a? o Q N No O m i LLZ Q � N ¢ 1 6 W 0 U O ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 1f 0 ON Z O W N >tn� r-a CD M Q� MLO 3:-Ln�0n Q LL CL M QU C- 0000 LILI J � d- J oZ �0 �o Za a� z8o U Z � W p w Z Lu 0 J rr n^ V / Lo J U N W m 2 � F_ Z Z o U w W Q W Z k- o 'Vr>/' l V � Li. Z J a V (n � LU Z W O LL .,`...�^` LLI Qo0 J XO6 N Q b co, Z�oa < Z< cr_ Q d - �Owc� i O Z N Zoo z Lu Lrn LLI �Z J �...I o W o �><a O ko ¢ Q z i`o Q Z 00 z Cy aZ O n g = `Z LU rn SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 SHEET NO. W P Q _4 - N O L L Florida Statewide Simpson Florida Statewide USP Evaluation Report Evaluation Report Q O ^0 Product Approval No. Basis Stock No. Product Approval No. C 0- .� U � N � Ca (� in O O O O Q� O LL -� O 0 Qp L c -/ 402 -1 .� VJ Q W z �_ �r 0 L 0 Q U O L VJ U I- O L LLJ J z a SHEET NO. PA 1. 0 r4 t rICU ICU t A3 FL17244.1 ESR-3455 A23 FL10446.2 ESR-2606 HD210-2 FL17232.3 ESR-3445 HU210-2 FL10655.20 ESR-2549 HD212-2 FL17232.3 ESR-3445 HU212-2 FL10655.23 ESR-2549 HD216 FL17232.3 ESR-3445 HU216 FL10655.29 ESR-2549 HD216-3 FL17232.3 ESR-3445 HU216-3 FL10655.29 ESR-2549 HD26 FL17232.2 ESR-3445 HU26 FL10655.31 ESR-2549 HD28-2 FL17232.3 ESR-3445 HU28-2 FL10655.34 ESR-2549 HD410 FL17232.4 ESR-3445 HU410 FL10655.44 ESR-2549 HD412 FL17232.4 ESR-3445 HU412 FL10655.45 ESR-2549 HD610 FL 17232.4 ESR-3445 H U61 D F L10655.51 ESR-2549 HD0410 FL17241.5 ESR-3444 HUC4410 FL11468.11 SIM200804 HGA10KT FL17236.6 ESR-3448 HGA10KT FL11470.4 SIM200803 HGAM10KT FL17699.1 Evaluation Report HGAM10KT FL11470.4 SIM200803 HHCP2 FL17236.7 ESR-3448 HCP2 FL10447.2 ESR-2551 HTA16 FL17680.2 Evaluation Report HETA16 FL11473.5 SIM200802 HTA20-18 FL17680.2 Evaluation Report HETA20 FL11473.5 SIM200802 HTT16 FL17324.1 Evaluation Report HTT16 FL11496.1 ES-0130 HTT45 FL17324.1 Evaluation Repo PRODUCT APPROVAL SPECIFICATION SHEET As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable fisted products. Category/Subcategory Manufacturer Product Description Approval Number(s) Test Pressures 1. EXTERIOR DOORS A. SWINGING ThermaTru Smooth -Star and Benchmark FL15225.5 +67.0(-67.0 psf ThermaTru Premium, Construction Series and Benchmark FL15225.6 +47.0/-47,0 psf ThermaTru Fiber Classic /Smooth Star FL15000.1 +55.0/-55.0 psi B. SLIDING General Aluminum Company Series 420/430 FL15332.1 - FL15332.5 +40.0/-40.0 psf C. SECTIONAL Clopay Building Products Residential WindCode Doors W5 (8X7) FL15279.37 +30.0I-32.0 psf Clopay Building Products Residential WindCode Doors W5 (16X7) FL15279.53 +30.0/-30.0 psf Clopay Building Products Residential WindCode Doors W6 (8X7) FL15279.85 +38.0/-42.0 psf Clopay Building Products Residential WndCode Doors W6 (16X7) FL15279.102 +37.0/-41.0 psf D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,and 847 Single &Pairs of Doors FL11537.1 N/A (see lost sht) 2. WINDOWS A. SINGLE HUNG General Aluminum Company Series 1550/1570 FL15217.4 - FL15217.5 +50.0/-55.0 psf General Aluminum Company Series 1900/1970 FL15217.7 - FL15217.9 +40.0/-50.0 psf B. HORIZONTAL SLIDER General Aluminum Company Series 1580l1590 FL15288.1 - FL15288.2 +40.0/-50.0 psf General Aluminum Company Series 1980/1990 FL15288.3 - FL15288.4 +40.0/-50.0 psf C. FIXED General Aluminum Company Series 1550/1570 FL15278.4 - FL15278.5 +40.0/-40.0 psf General Aluminum Company Series 1900/1970 FL15278.7 - FL15278.9 +40.0/-50.0 psf D. MULLION General Aluminum Company 1445, 5347 and 5547 Vertical Mullion FL15333.7 N/A E. OTHER 3. PANEL WALL A. SIDING James Hardie Building Prod. Cemplank Lap Siding and HardiePlank Lap Siding FL13192.1 - FL13192.2 N/A B. SOFFITS Alside Solid and Vented Soffit FL15272.1 - FL15272.2 +70.0l-70.0 psf C. OTHER 4. ROOFING PRODUCTS A. ASPHALT SHINGLES Certain Teed Corporation CT20 (and AR), Landmark 30/40 (and AR), FL5444.1 N/A XT25 (and AR), XT30 (and AR) B. UNDERLAYMENTS Tamko 151b Felt Undertayment FL12328.6 N/A HomeGuard Building Products, Inc ToughSkin Synthethic Undedayments FL21675.1 N/A C. ROOFING FASTENERS NOT USED D. ROOF VENTILATORS Thompson Arch Metal Comp. Off Ridge Vents FL5219.1 - FL5219.3 N/A Florida Metal Products, Inc Vent RV10 FL2075.1 N/A Lomanco, Inc DA-4 Exahust Vent FL17202.1 N/A O'Hagin Manufacturing, LLC O'Hagin's Ctoakded Vent Tile FL16588.1 N/A E. ROOFING TILES Boral Tile Villa 9D0 FL7849.24 - FL7849.26 N/A Boral Tile Saxony 900 FL7849.13 - FL7849.16 N/A F. OTHER 5. SHUTTERS A. STORM PANELS Global Protection Products Galvanized Steel Storm Panels FL15076.1 - FL15076.2 N/A Global Protection Products GPP Fabric Shutter Series 2000 FL15088.1 N/A Town and Country Industries Safety Edge Storm Panels FL12856.1 +54.0l-54.0 psf All American Shutters Galvanized Steel Storm Panels FL17869.1 N/A 6. STRUCTURAL COMPONENTS A. WOOD CONNECTORS/ USP Structural Conn. see chart ANCHORS Simpson Strong -Tie see chart $. TRUSS PLATES ITW Building Components Alpine Truss Plates FL1999.1 - FL1999.4 N/A MiTek Industries, Inc. Truss Plates FL2197.1-FL2197.5 N/A C. ENGINEERED LUMBER Boise Eng. Wood Prod. Versa -Lam SP FL1644.1 N/A Boise Eng. Wood Prod. Wood I -Joists ALLJOIST FL1645.1 N/A Weyerhaeuser Engineered lumber-TJI FL1630.1-FL1630.11 N/A Weyerhaeuser iLevel Rim Board, LVL, PSL, LSL FL6527.1-FL6527.4 N/A D. MATERIAL Cast -Crete Corp. High Strength Concrete Lintels FL158.1 N/A Commercial Concrete Products, Inc. High Strength Concrete Lintels FL1774 N/A Powers Steel, Inc. PSbox8LT, PSbox8LT(5-5/8) FL5450.1 N/A Powers Steel, Inc. PowerBOXB Lintels FL11383.1 N/A The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I understand these products may have to be removed if approval cannot be demonstrated during inspection. APPLICANT SIGNATURE DATE CD rn Cu N -� � N p� L L 0 N IL O CUU-a� te Florida Department of Business & Professional Regulation Page 1 of 2 Florida Department of Business & Professional Regulation Page 1 of 1 + W V n n 1 }� Building Codes and Standards 1192017 Building Codes and Standards 119/2017 Florida Department of Business & Professional Regulation Page 1 of 2 V � -0 Product Approval Application Detail Product Approval Application Detail Building Codes and Standards 1/92017 O O . .0 2 � FL#15225-R3 FL#15000-R2 Product Approval Application Detail O O 0 O 0 LL Code Tyne Versio Manufacturer Enti or Contact Engineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Code Type Versio Manufacturer Entity or Conte Engineer &License Validated By Date Date Date Pending Validated Submitted FBC Approval Date Approved Status FL#15332-R3 Products O � � CU O > Revision 2014 Therma-Tru Corporation Rick Wright National Accreditation & Ryan J. King, P.E. 06/28/2015 06/13/2015 07/05/2015 Approved Revision 2014 Therma-Tru Corporation Rick Wright Lyndon F. Schmidt, P.E. Ryan J. King, P.E. 06/28/2015 05/29/2015 07/05/2015 08/19/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Design .D_ -0 O Category: Exterior Doors g ry: (419 298-1740 Management ) ) g (813 767-6555 Category., Exterior Doors (419) 298-1740 PE-43409 (813) 767-6555 Se # � Product Model Number or Name c Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure L Subcategory: Swinging Exterior Door Assemblies rickw@rwbldgconsultants. Subcategory: Swinging Exterior Door Assemblies Compliance Report from rickw@rwbldgconsultants. 4 SERIES 420 ALUMINUM SGD REINFORCED SERIES 420 ALUMINUM SGD REINFORCED OX, 12/31/2017 No Yes No N/A � O }� CU Compliance Method: Certification Mark or Listing com Method: Evaluation a com XO, XX 96"x96" �. � ICU Q FL#15225-R3 Products Florida Registered Architect or a Licensed Florida 5 SERIES 420 ALUMINUM SGD REINFORCED SERIES 420 ALUMINUM SGD REINFORCED XXX 12/3112017 No Yes No N/A Professional Engineer 143"x96" .� Quality Assurance Approved for Use Approved for Use Impact Design 7 SERIES 420 REINFORCED ALUMINUM SGD SERIES 420 REINFORCED ALUMINUM SGD QXO 12131/2017 No Yes No N/A Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15000-R2 Products 146"x96" 5 e. &quo-; and " Benchmark by and 8/u Opaque and Glazed Fiberglass Door with 12/3112021 No Yes No NIA 8 SERIES 430/440 ALUMINUM SGD SERIES 430/440 ALUMINUM SGD XXX 12/31/2017 No Yes No N/A ru&quh-Star"a Therms-Tru" an and without Sidelites. Inswing and Quality Assurance Approved for Use Approved for Use Impact Design 143"x80"a NON -REINFORCED 6 f. ",Premium Series"a, "Construdion eel Door 6/8 and 8!0 Opaque and Glazed Steel Door with 12l31/2021 No Yes No N/A Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 9 SERIES 430/440 REINFORCED ALUMINUM SGD SERIES 430/440 REINFORCED ALUMINUM SGD 12/3112017 No Yes No NIA Series" and "Benchmark by Therma-Tru" Transoms. With and without Sidelites. Inswing and 1 a. &quct;Fiber-Classic" or "Smocth-Star" 6'8 "Non-Impact" Opaque Fiberglass 12131/2018 Yes Yes No N/A XXX 143& quot;x96& uo q t; with Transoms Outswing Door with & without Sidelite(s) - Outswing (X, OX or XO, OXO, XX, OXXO Configurations) Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/9/2017 Product Approval Application Detail Florida Department of Business & Professional Regulation Paget oft Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/9/2017 FL#15279-R4 Building Codes and Standards 1/10/2017 Product Approval Application Detail Code Entity r Date Date pate Pend Ina Delta Product Approval Application Detail Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#15217-R4 Revision 2014 Clopay Building Products Company Mark Westerfield Intertek Testing Services NA, Gary Pfuehier 06/12/2015 03/19/2015 06/21/2015 Approved FL#11537-RS Code Entity or Date Date Date Pend Ina Date CategoryExterior Doors {513) 770 6062 Inc. {513) 519656E Code Entity or Date Date Date Pend Ina Date Type Versio Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status Subcategory: Sectional Exterior Door Assemblies mwesterfield@clopay.com Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval roved Status Revision 2014 MI Windows and Doors Brent Sitin er Luis Roberto Lomas Steven M. Urich, PE 9 06/30/2015 06/25/2015 07/06/2015 08/1912015 Approved PP Compliance Method: Certification Mark or Listing 2014 CURRIES Division of AADG, Inc Nelson Kraschel UL LLC Ted Berman, PE 07/21/2015 07121/2015 07/27/2015 Approved Category: Windows Subcategory: Single Hung 365-3300 PE-62514 (717) 317-8454 bsitinger@mMd.com bsitlinger@m"iwd.com FL#15279-R4 Products Category: Exterior Doors (641) 423.1334 (305) 868-4707 Compliance Method: Evaluation Report from a Quality Assurance Approved for Use Approved for Use Impact Design Subcategory: Exterior Door Components nelson.kraschel@doorgro Florida Registered Architect or a Licensed Florida Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Compliance Method: Certification Mark or Listing up.com Professional Engineer 37 037 W5-09 PAN-21`151: 84A, 94, 73, 75, 1500, 190, 76, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/21/2028 No Yes No +30 PSF/-32 FL#11537-R6 Products FL#15217-R4 Products 76V, 4RST, 4RSF, 6RST, 6RSF, 2RST, 48, 42, 55, 48B, WINDCODE® W5 Garage Door PSF Quality Assurance Approved for Use Approved for Use I Pact Design Quality Assurance Approved for Use Approved for U Use Impact S De i n 42B, 55S, GD5S, GD5SV, GR5S, GR5SV, ARSS, AR5SV, ED5S, ED5SV Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ -�- Resistant Pressure 1 607, 707, 727, 747, and 847 Single and Pairs of Doors Flush, Glazed, and Lowered single and pairs of 12/31/2017 Yes Yes Yes N/A 4 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 44X84 12/31/2017 No Yes No N/A 53 053 W5-16 PAN-2F153: 84A, 94, 73, 75, 1500, 190, 4RST, Steel Pan (min. 25 ga.) Double -Car (92' to 160" 05/21/2028 No Yes No +30 PSF/-30 2 M, CM, and G Series Frames hollow metal doors. Three sided and four sided single and pairs of 12/31/2017 Yes Yes Yes NIA 5 7 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 54X72 12131/2017 SERIES GA 195 ALUMINUM SH NI 54)(72 12131/2017 No No Yes Yes No No N/A N/A 4RSF, 6RST, 6RSF, 48, 42, 55, 48B, 42B, 55S, GDSS, wide) WINDCODE® W5 Garage Door PSF frames. Tansom frames. 8 SERIES GA 195 ALUMINUM TRIPLE SH SERIES GA 195 ALUMINUM TRIPLE SH NI 12/31/2017 No Yes No N/A GD5SV, GR5S, GR5SV, ARSS, AR5SV, ED5S, ED5SV CONTINUOUS HEAD AND SILL 108X72 NON 85 085 W6-09 PAN-21`153: 73, 75, 84A, 94, 42, 48, 42B, 488, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/2112028 No Yes No +38 PSFI-42 9 SERIES GA 195 ALUMINUM TWIN SH IMPACT SERIES GA 195 ALUMINUM TWIN SH NI 12/3112017 No Yes No N/A 4RST, 6RST, GDSS, GR5S, ARSS, ED5S WINDCODE® W6 Garage Door PSF CONTINUOUS HEAD AND SILL 881/8X72 102 102 W6-16 PAN-2F153: 73, 75, 84A, 94, 42, 48, 42B, 48B, 4RST, 6RST, GDSS, GR5S, ARSS, ED5S Steel Pan (min. 25 ga.) Double -Car (9'2" tD 162" 05/21/2028 wide) WINDCODE® W6 Garage Door No Yes No +37 PSFI-41 PSF Florida Department of Business & Professional Regulation Page 1 of Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Building Codes and Standards 1/9/2017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 1 O Product Approval Application Detail Building Codes and Standards 1/9/2017 . ri FL#15278-R4 Product Approval Application Detail FL#15288-R2 Code Entity or Date Date Date Pending Date Code Entity or at Date Date Pendina DateFL#15333-R2 Typo Versio Manufacturer Contact Enaineer&License Validated By Validated Submitted FBC Approval Approved Status Type Versio Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 09/01/2015 08/31/2015 09/05/2015 10/16/2015 Approved Affirmation 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 04/30/2016 04/30/2015 05/10/2015 Approved Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Coe Entity o Date Date Date Pendino Date Category: Windows (717)365-3300 PE-62514 (717)317-8454 Subcategory: Fixed bsitinger@miwd.com Type Versio Manufacturer Contact Engineer &License Validated By Validated Submitted FBC Approval Approved Status Subcategory: Horizontal Slider bsitlinger@miwd.com Compliance Method: Evaluation Report from a Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 06/29/2015 06/19/2015 07/05/2015 08/19/2015 Approved Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Registered Architect or a Licensed Florida Professional Engineer Subcategory: Mullions g ry: bsitinger@mKvd.com nger@miwd.com Professional Engineer FL#15278-114 Products Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida FL#15288-R2 Products Quality Assurance _Approved for Use Approved for Use Impact Desian Professional Engineer Quality Assurance Approved for Use Approved for Use Impact Design Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15333-R2 Products Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVH Resistant Pressure 4 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 96X48 FIN 12131/2017 No Yes No NIA 1 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12/31/2017 No Yes No N/A 5 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 72X72 12/31/2017 No Yes No NIA Quality Assurance p Approved for Use Approved for Use Impact Desi �6 72X54 FLANGE Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12/3l/2017 No Yes No N/A 7 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 96X48 12/31/2017 No Yes No N/A 7 1445, 5347 AND 5547 VERTICAL MULLION 1445, 5347 AND 5547 VERTICAL MULLION 12131/2017 No Yes Yes NIA 72X54 FLANGE 3 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/31/2017 No Yes No N/A 8 SERIES GA 275 THERMALLY BROKEN ALUMINUM PW SERIES GA 275 THERMALLY BROKEN ALUMINUM 12/31/2017 No Yes No NIA fJ SERIESGA198 9 SERIES GA 505 ALUMINUM PW PW NI SERIES X72FIN SERIES GA 505 ALUMINUM PW NI 72X72 FIN 12/31/2017 No Yes Na NIA ^` 4 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/31/2017 SLIDER No Yes No N/A � V 0 CU O L� i...L U .ram■ � o Florida Department of Business & Professional Regulation Page 1 of 2 Florida Department of Business & Professional Regulation Page 1 of 1 Florida Department of Business & Professional Regulation Page 1 of 2 Building Codes and Standards 1/912017 Building Codes and Standards 1/92017 Building Codes and Standards 1/92017 c Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail (f� FL#13192-R4 FL#15272-R1 FL#5444-R10 ■ Code Entity or Date Date Date Pend Ina Date Code Entity or a Date Date Pendina Date Code Entity or Date Date Date Pendina Date Type Versio Manufacturer Contact Eno ineer&License Validated By Validated Submitted FBC Approval Approved Status Type Versio Manufacturer Contact Enaineer&License Validated By Validated Submitted FBC Approval Approved Status Tyg_e Versio Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 James Hardie Building Products, Inc. Pingsheng Zhu Ronald I. Ogawa John Southard, P.E. 08/26/2015 08/17/2015 09/07/2015 10/16/2015 Approved Revision 2014 Alside Nick Thompson Lyndon F. Schmidt, P.E. Ryan J. King, P.E. 02/23/2015 02/19/2015 =01/2015 04/15/2015 Approved Revision 2014 CertainTeed Corporation -Roofing Mark Harper Robert Nieminen John W. Knezevich, PE 12/14/2016 12/08/2016 12/15/2016 PendingFBC Approval pp Category: Panel Walls (909) 349.2927 PE-24121 (352) 367-2526 Category: Panel Walls (330) 922-2380 PE-43409 (813) 767.6555 Category: Roofing (610) 651-5847 PE-59166 (95d) 772-6224 a, Subcategory: Siding Compliance Method: Evaluation Reportfrom pingsheng.zhu@jameshar die.com Subcategory: Soffits Compliance Method: Evaluation Report from nthompson@alside.com Subcategory: Asphalt Shingles Compliance Method: mark d.harner@saint-gob a Florida Registered Architect or a Licensed Florida a Florida Registered Architect or a Licensed Florida Evaluation Reportfroma Florida Registered Architect or a Licensed Florida ain.com Professional Engineer Professional Engineer Professional Engineer /L_ FL#131927R4 Products FL#t5272-R1 Products IC V Quality Assurance Approved for Use Approved for Use Impact Design Quality Assurance Approved for Use Approved for Use Impact � Desi �_n FL#5444-R10 Products W Sea # Product Model- Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Quality Assurance Approved for Use Approved for Use Impact Desian 1 Cemplank Lap Siding fiber -cement lap siding 0110112018 Yes Yes N/A NIA 1 a. "2T" Soffit Vent or Solid Vinyl Soffit 12/31/2018 No Yes No N/A Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Q t11 W 2 HardiePlank Lap Siding fiber -cement lap siding 01/01/2018 Yes Yes N/A N/A 2 b. "Alliance T4" Soffit Vent or Solid Vinyl Soffit 12/31/2018 No Yes No N/A 1 CertainTeed Asphalt Roofing Shingles 3-tab, 4-tab, strip (no -cut-outs), laminated and 07/03/2017 No Yes NIA N/A Z architectural asphalt roof shingles Z 'Q J d SHEET NO. PA 1.1 O L C/) Cu v am o L O- O Florida Department of Business & Professional Regulation Page 1 of 1 Q O /� Building Codes and Standards 1/9/2017 CU LL Florida Department of Business & Professional Regulation Pagel of Florida Department of Business & Professional Regulation Page 1 of I Building Codes and Standards 1/92017 Building Codes and Standards 2162017 Product Approval Application Detail CU42) .� Product Approval Application Detail Product Approval Application Detail FL#5219-R3 0 .� FL#12328-R7 Products Code Entity or Date Date Date Pending Date I` _O O Q Q Quality Assurance Approved for Use Approved for Use Impact Desian FL#21675-RO Type Versio Manufacturer Contact Engineer & License Validated By ValidatedSubmitted FBC Approval Approved Status O seg # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Coe Entity or Date Date Date Pendina Date Revision 2014 Thompson Architectural Metals Company, Inc. Scott Brown James L. Buckner Steven M. Urich, PE 05/01/2015 04/29/2015 05/10/2015 06/23/2015 Approved M 6 No. 15 UL Asphalt saturated organic felt 01/07/2019 No Yes N/A NIA Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Category: Roofing (813) 248-3456 PE-31242 (717) 317-8454 O � 4—ca j New 2014 HomeGuard Building Products, Inc. John Cheslak Intertek Testing Services NA, IntertekTesting Services 02/01/2017 01/25/2017 02103/2017 SubCategory: Roofing Accessories that are an Part the Roofing System flvalidation@yahoo.com Approved ntegral of E L Inc. Compliance Method: Evaluation Report from a Category: Roofing (904) 240-1382 NA, Inc. Florida Registered Architect or a Licensed Florida Search Criteria Subcategory: Underlayments john.cheslak@hgwrap.co (604) 520-3321 Professional Engineer �1� Q Compliance Method: Evaluation Report from a m FL#5219-R3 Products Code Version: 2014 FL A. 12328 Product Evaluation Entity Application Type: ALL Product Manufacturer: ALL FL#21675-RO Products Quality Assurance Approved for Use Approved for Use Impact Design Category: g rY� ALL Subcategory: ALL e9 ry� e # S _ Product Model. Number or Name Product Description Contract Expiration Date n HVHZ L., V � Outside HVHZ Resistant Pressure r Application Status: ALL Compliance Method: ALL Quality Assurance Approved for Use Approved for Use 1 act Desian 1 1- "Flat Top Off Ridge Vent with Baffle for Tile" Minimum 26 Gauge Steel, Nominal 4', 6', 12/31/2019 No Yes No N/A Quality Assurance Entity Contract Expired: ALL Product Model, Number or Name: ALL Seg # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 8', or 10',, Wide Off Ridge Vent Attached to Product Description: ALL Approved for use in HVHZ: ALL 1 ToughSkin Synthetic Underlayments ToughSkin 15, ToughSkin 20, ToughSkin 25, 01/01/2018 No Yes WA N/A Wood Deck ToughSkin 30, ToughSkin 50 2 2- "Round Top Off Ridge Vent with Baffle for Minimum 26 Gauge Steel, Nominal 4', 6', 12131/2019 No Yes No N/A Approved for use PP Outside HVHZ: ALL Impact Resistant. ALL P Tile" 8', or 10' Wide Off Ridge Vent Attached to Design Pressure: ALL Date From: ALL Wood Deck Date To: ALL 1 1 3 3- "Standard Off Ridge Vent with Permanent Baffle Minimum 26 Gauge Steel, Nominal4', 6', 12131/2019 No Yes No NIA for Shingles" 8', or 10' Wide Off Ridge Vent Attached to Wood Deck Florida Department of Business & Professional Regulation Page 1 of 1 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/10/2017 Florida Department of Business &Professional Regulation Pagel of 1 LU Building Codes and Standards 1192017 Product Approval Application Detail Building Codes and Standards g 1/102017 Product Approval Application Detail Product Approval Application Detail FL#17202-R1 FL#2075-R7 Code Entity or Date Date gate Pendina Date FL#16588-R1 mi Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Code Type Versio Manufacturer Entity or Contact Engineer &License Validated By gaLe Date Validated Submitted Date Pending FBC Approval Date Approved Status Revision 2014 Lomanco, Inc Andrew Carter James L. Buckner, P.E. Steven M. Urich, PE 05/01/2015 05/01/2015 05/10/2015 06/22/2015 Approved Code Entity or Date Date Date Pending ate Category: Roofing (501) 982-6511 PE-31242 (717) 317-8454 Type Versio Manufacturer Contact Engineer& License Validated By Validated Submitted FBC Aovroval Approved Status Affirmation 2014 Florida Metal Products Inc. Clark Jones Miami -Dade BCCO - EVIL Dade15-2 BCCO - VAL 0212712015 O2/27/2015 03/09/2015 Approved Subcategory. RoofingAccessories that are an g acarter@iomanco.com Affirmation 2014 O'Ha in Manufacturing,LLC g Gregory Daniels Miami -Dade BCCO - CER Ted Berman, PE g ry 06/17/2015 06/17/2015 06/25/2015 Approved pP Category: Roofing (904) 783 8400 (786} 315-2590 (786) Subcategory: Roofing Accessories that are an clark@flamco.com Integral Part of the Roofing System Category: Roofing (707) (305) 868-4707 Integral Part of the Roofing System Compliance Method: Evaluation Report from a Subcategory: Roofing Accessories that are an [s gdanieLs@ohagohagin.com Florida Registered Architect or a Licensed Florida Integral Part of the Roofing System Compliance Method: Evaluation Report from a Professional Engineer Compliance Method: Certification Mark or Listing Product Evaluation Entity FL#2075-R7 Products FL#17202-R1 Products FL#16588-R7 Products Quality Assurance Approved for Use Approved for Use Quality Assurance _Approved for Use Approved for Use Impact esi n Quality Assurance Approved for Use Approved for Use Im act Design Seg # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ eImpactDesign Resistant Pressure Se0 # Product Model. Number or Name Product Description Contract Expiration Date HVHZ Outside HVHZ esista t Pressure Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 RV10 RVIO ALUMINUM RIDGE VENT 01/31/2018 Yes Yes N/A N/A 1 Deck -Air- DA-4 Low Profile, Polypropylene Plastic, Roof Vent 07/10/2019 No Yes No +97.51-97.5 1 0'Hagin's Cloaked Vent Tile Attic Ventilation Product for tile roofing applications 04/04/2018 Yes Yes N/A N/A Mechanically Attached to Plywood Deck. 2 OmniRidge® PRO Vent PR04-N Molded Plastic, Roof Ridge Vent Mechanically 07/10/2019 No Yes No +N/A/-165 Attached to OSB or Plywood Deck. CZ (D Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards VV2017 Q Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 3 FL#15076-R3 Building Codes and Standards 1/92017 Code Entity or Date gate Date Pending Date Tvpe Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status O Product Approval Application Detail Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 05/06/2015 04/24/2015 05/11/2015 06/23l2015 Approved Florida Department of Business & Professional Regulation Page 1 of 1 Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 Building Codes and Standards 1/9rz017 ■ � SubCategory: Storm Panels tim.robinson@gppent.com FL#7849-R9 Compliance Method: Evaluation Report from a Product Approval Application Detail Florida Registered Architect or a Licensed Florida Code Entity or Date Date Date Pending Date Professional Engineer Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#15088-RI Revision 2014 Boral Roofing / Monierl-ifetile Thomas Jemmett ICC Evaluation Service, LLC Gary W. Walker 09/10/2015 08/25/2015 09/20/2015 Approved FL#15076-R3 Products )asjemmett@boral.co 9-2288 (205) 854-0160 uality Approvedved for a Use AOus Impact Code Entity or Date Date te Pend inci BC SubCategory: Roofing Tiles thoming Sea # Product Model. Number or Name Product Description Contract Expiration Date n HVHZ de HVHZ j_ Resistant R st nT Pressureesign ype Versio Manufacturer t _ Contact Engineer&License Validated By Validated Submitted Approval Approved Status Compliance Method: Evaluation Report from a m 1 20 Gage Galvanized Steel Storm Panels/HVHZ Corrugated Galvanized Steel Storm Panels retained 12131/2017 Yes Yes Yes NIA Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A Tillit Jr., P.E. John W. Knezevich, PE 04/27/2015 04/24/2015 05/03P2015 06/23/2015 Approved ■ Product Evaluation Entity or not by tracks to provide hurricane protection. Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 �■ 2 24 Gage Galvanized Steel Storm Panels/NHVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 No Yes Yes N/A SubCategory: Fabric Storm Panel tim.robinson@gppent.com FL#T849-R9 Products or not by tracks to provide hurricane protection. Compliance Method: Evaluation Report from a Quality Assurance Approved for Use Approved for Use Im pact Design Florida Registered Architect or a Licensed Florida Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15076-R4 Professional Engineer 13 Saxony 700 - Shake, Slate & Split Shake Flat Profile - Stockton 1213112018 No Yes N/A N/A Code Entity or Date Die Date Pending Date FL#15088-RI Products 14 Saxony 900 - Country Slate, Shake & Slate Flay Profile - Henderson 12/31/2018 No Yes N/A N/A Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Quality Assurance Approved for Use Approved for Use Impact Desian 15 Saxony 900 - Country Slate, Shake, Slate & Split Flat Profile - Lake Wales 12/31/2018 No Yes N/A NIA Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 12/21/2016 12/21/2016 Validated S- # Product Model. Number or Name Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure Shake Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 1 GPP FABRIC SHUTTER -SERIES 2000 Coated Polyethylene Fabric Panels retained by tracks 12/3112017 No Yes Yes N/A 16 Saxony 900 - Hartford Slate, Split Old English Thatch, Flat Profile - Stockton 12/31/2018 No Yes NIA N/A SubCategory: Storm Panels tim.robinson@gppent.com or direct mounted to provide hurricane protection. Shake, Slate, Country Slate Compliance Method: Evaluation Report from a 24 Villa 900 Medium Profile - Lake Wales 12/31/2018 No Yes N/A N/A Florida Registered Architect or a Licensed Florida 25 26 Villa 900 Villa 900 Medium Profile - Denver 12/31/2018 Medium Profile Stockton 12/31/2018 No No Yes Yes N/A N/A NIA N/A Professional Engineer - FL#15076-R4 Products Sea # Product Model, Number or Name Quality Assurance Approved for Use Approved for Use Product Description Contract Expiration Date in HVHZ Outside HVHZ Impact Resistant Desian Pressure w v, 1 20 Gage Galvanized Steel Storm Panels/HVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes NIA 2 24 Gage Galvanized Steel Storm PanelslNHVHZ or not by tracks to provide hurricane protection. Corrugated Galvanized Steel Storm Panels retained 12/31/2017 No Yes Yes N/A O (v or not by tracks to provide hurricane protection. L. U Florida Department of Business & Professional Regulation Page l of 1 Building Codes and Standards 1/92017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 2 Florida Department of Business & Professional Regulation Page 1 of I Building Codes and Standards 1/92017 Building Codes and Standards 1/9/2017 CD FL#12856-RS Product Approval Application Detail Product Approval Application Detail (n Code Entity or Date, Date Date Pendina DateICU Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#17869-RO FL#1999-R5 M Revision 2014 Town and Country Industries, Tom Johnston Frank I. Bennardo ORLANDO L. BLANCO, 04/29/2015 04/28/2015 05/04/2015 O6/22/2015 Approved ■ � ■ Category: Shutters SubCategory: Storm Panels (954) 493.8551 PE-0046549 P.E. tomj@tc-alum.com (305) 510-8531 Code Tvpe Versio Manufacturer Entity o Contact Engineer & License Validated By Date Date Date Pending Validated Submitted FBC Approval Date Approved atus Code Type Versio Manufacturer Entity or Contact Enaineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Compliance Method: Evaluation Report from a New 2014 All American Shutters and Glass Mike Barbieri Frank L. Bennardo, RE Jorge A. Pomerantz, P.E. 07/03/2015 07/03/2015 07/10/2015 08/18/2015 Approved PP Revision 2014 ITW Building Components Group Inc. ! Paslode 9 p p^ Stuart Lewis [CC Evaluation Service LLC William M. Ranier PE 03/25/2015 03/20/2015 03/29/2015 Approved Florida Registered Architect or a Licensed Florida Category: Shutters (561) 712-9882 PE-0046549 (954) 394-8521 Category: Structural Components (847) 918-6473 (407) 681-1917 L.L. Professional Engineer SubCategory: Storm Panels mikeb@allamericanshutte SubCategory: Truss Plates slewns@alpineitw.com FL#12856-R5 Products Compliance Method: Evaluation Report from a rs.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Product Evaluation Entity L� Quality Assurance Approved for Use Approved for Use Impact i n Professional Engineer FL#1999-R5 Products sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#17869-RO Products 1 0.050" Aluminum Storm Panel 0.050& q uot; Aluminum Storm Panel with Optional 12/31/2018 No Yes Yes N/A Quality Assurance Approved for Use Approved for Use Impact Design W 2 "Safety Edge" Clear Panels "Safety Edge" Storm Panels, 28ga 12131/2018 No Yes Yes +54/-54 Quality Assurance Approved for Use Approved for Use Impact Design Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Storm Panels Seg # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 ITW BCG Higher Strength (H & S) Metal Connector Plate 12/3112020 Yes Yes N/A NIA (0.018"") Steel, 0.022" Alum (Pert 1 22ga, 24ga Steel Panels 22ga, 24ga Steel Storm Panels 12/31/2017 No Yes Yes N/A 2 ITW BCG Hinge Plate Metal Connector Plate 12131/2020 Yes Yes NIA N/A Q ^, �✓ W 3 24ga Steel Storm Panel and Non -Pert), Clear Polycarb (Full and Halo 24ga (0.0232"a) Steel Storm Panel with Optional 12/31/2018 No Yes Yes +100/-100 3 ITW BCG Trulox Metal Connector Plate 12/3112020 Yes Yes N/A NIA Z Clear Panels 4 ITW BCG Wave Metal Connector Plate 12/3112020 Yes Yes NIA NIA z 4 Aluminum Hinged Storm Panel .050", Aluminum Non -Porous Hinged Storm 12/31/2018 Yes Yes Yes N/A Panel Q J d SHEET N0. PA 1. 2 FL#2197-RS Code Type YlEjig Manufacturer Revision 2014 MiTek Industries, Inc. Category: Structural Components SubCategory: Truss Plates Compliance Method: Evaluation Report from Product Evaluation Entity FL#2197-R5 Products Sea # Product Model. Number or Name 1 M18SHS 2 Mil 16 3 MT18HS 4 MT20 5 MT20HS FL#1630-RB Code Tvpe Versio Manufacturer Revision 2014 Weyerhaeuser Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#1630-R8 Products Secl # Product Model, NumberorNam e 1 TJI 110 2 TJI 210 3 TJI230 4 TJI360 5 TJI560 6 TJ11560D Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Product Approval Application Detail Entity or Date Date Date Pendina Date Contact Engineer & License Validated By Validated Submitted FBC Approval Aporoved Status David Wert ICC Evaluation Service, LLC ICC Evaluation Service, 06/30/2015 06/11/2015 07/05/2015 Approved (314)851-7480 LLC. dwert@mii.com (205) 599-9800 Quality Assurance Approved for Use Approved for Use Impact Desian Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 18 ga. super high strength truss connector plate 12/31/2017 Yes Yes N/A N/A 16 ga. truss connector plate 12/31/2017 Yes Yes N/A N/A 18 ga. high strength truss connector plate 12/31/2017 Yes Yes N/A N/A 20 ga. truss connector plate 12131/2017 Yes Yes N/A NIA 20 ga. high strength truss connector plate 12/31/2017 Yes Yes N/A NIA Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 119/2017 Entity or Date Date Date Pendina pate Contact Enalneer & License Validated By Validated Submitted FBC Approval Anproved Status Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 07/06/2015 05/12/2015 07/30/2015 Approved (253) 924-4084 (608) 839-1344 j i m.a nderson2@weye rhae user.com Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressur Prefabricated Wood I -joist 03/31/2017 No Yes NIA N/A Prefabricated Wood 1-joist 03/31/2017 No Yes N/A N/A Prefabricated Wood I -joist 03/31/2017 No Yes NIA NIA Prefabricated Wood I joist 03131/2017 No Yes N/A WA Prefabricated Wood I -joist 0313112017 No Yes N/A N/A Prefabricated Wood I -joist 03/3112017 No Yes N/A NIA Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail FL#1774-R4 Code Entity or Tvpe Verslo Manufacture Contact Engineer & License Revision 2014 Commercial Concrete Products,inc. Robert Gillis THUY H. HUYNH Category: Structural Components (813) 659-3707 PE-60122 SubCategory: Products Introduced as a Result of precastgator@yahoo.com New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#1774-R4 Products Sag # Product Model. Number or Name Product Description 1 Quality Precast or Commercial Concrete Products Precast and Prestressed Concrete Lintels 1 Validated By Florida Engineering Solutions (352) 588-5311 Page 1 of 1 1/92017 Date Date Date Pendina Date Validated Submitted FBC Approval Approved Status 07/03/2015 06/24/2015 08/20/2015 08/26/2015 Approved Quality Assurance Approved for Use Approved for Use hiinact Design Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 05/2512024 No Yes N/A WA FL#1644-R4 code IYL Versio Manufacturer Revision 2014 Boise Engineered Wood Products Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#1644-R4 Products Sea # Product Model. Number or Name 1 Versa -Lam Search Criteria FL#6527-R6 Code Tyne Versio Manufacturer Revision 2014 Weyerhaeuser Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#6527-R6 Products Sea # Product Model, Number or Name 1 Level Rim Board 2 Microliam LVL 3 Parallem PSL 4 TimberStrand LSL FL#6527-R7 Code Tvpe Versio Manufacturer Revision 2014 Weyerhaeuser Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#652T-R7 Products Seq # Product Model. Number or Name 1 Microllam LVL 2 Parallam PSL 3 TimberStrand LSL 4 TJ Rim Board 5 Weyerhaeuser Rim Board FL#5450-R5 Code Tvpe Versio Manufacturer Revision 2014 Powers Steel Inc. Category: Structural Components SubCategory Products Introduced as a Result of New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#5450-R5 Products Seci # Product Model. Number or Name 1 PSbox8LT, PSbox8LT(5-5/8) Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/9/2017 I nti or at Date Date Pending ate .Q�c � Contact Eno ineer& License Validated By Validated Submitted FBC Approval Approved Status Robert Taylor ICC Evaluation Service, LLC APA - The Engineered 05/27/2015 05/06/2015 06/02/2015 Approved (541) 826-0200 Wood Association roberttaylor@bc.com (253) 620-7467 Quality Assurance Approved for Use Approved for Use (Impact Desian Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Laminated Veneer Lumber 01/01/2036 No Yes N/A NIA Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/9/2017 Entity or Date Date Date Pending Date Contact Engineer & License Validated ev Validated Submitted FBC Approval Approved Status Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 07/06/2015 05/12/2015 07/30/2015 Approved (253) 924-4084 (608) 839-1344 jim.anderson2@weyerhae user.com Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes NIA N/A board Rim Board Laminated Veneer Lumber 03/31/2017 No Yes NIA N/A Parallel Strand Lumber 03/31/2017 No Yes N/A N/A Laminated Strand Lumber 03/31/2017 No Yes WA N/A Entity or Date Date Date Pendina Date Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 10/31/2016 10/25/2016 11/05/2016 Approved (253) 924-4084 (608) 839-1344 j i m.anderson2@weyerhae user.com Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Laminated Veneer Lumber 03/31/2017 No Yes NIA N/A Parallel Strand Lumber C3/3112017 No Yes N/A NIA Laminated Strand Lumber 03/31/2017 No Yes N/A N/A Structural Composite Lumber or Oriented Strand 03131/2017 No Yes N/A N/A board Rim Board Oriented Strand Board Rim Board 0313112017 No Yes WA NIA Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity or Contact Engineer & License william powers Steven W. Schaub (602) 437-1160 PE-60509 bill@powerssteel.com Product Description Powers Steel lintels are field assembled lintels consisting of preformed steel lintels combined with concrete masonry units, grout, and steel reinforcing bars. Validated By SAMUEL A. GREENBERG, RE, (813) 645-0166 Page 1 of 1 1/92017 Date Date Date Pendino Date Validated Submitted FBC Approval Approved Status 03/26/2015 03/23/2015 03/30/2015 06/23/2015 Approved Quality Assurance Approved for Use Aporoved for Use Impact esi Contract Expiration Date .in HVHZ Outside side HVHZ Resistan Pressure 01/27/2017 No Yes WA WA FL#1645-R4 Code TYPe Versio Manufacturer Revision 2014 Boise Engineered Wood Products Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#1645-R4 Products Sea # Product Model, Number or Name 1 AJS Joists Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/9no17 Entity o ate Date Date Pendina Date Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Robert Taylor ICC Evaluation Service, LLC APA - The Engineered 05/27/2015 05/08/2015 06/02/2015 Approved (541) 826-0200 Wood Association roberttaylor@bc.com (253) 620-7467 Quality Assurance Approved for Use Approved for Use Impact Desian Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Wood "l" Joists 01/01/2035 No Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail FL#158-R7 Code Type Versio Manufacturer Contact Revision 2014 CAST-CRETE USA, Inc. Craig Parrino Category: Structural Components (813) 621-4641 SubCategory: Products Introduced as a Result of cparrino@castcrete.xom New Technology Compliance Method: Certification Mark or Listing FL#158-R7 Products Page 1 of 1 1192017 Entity or Dome Date Date Pendina Dig Engineer& License Validated By Validated Submitted FBC Approval Aporoved Status Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 03/16/2015 02/24/2015 03/18/2015 Approved (786) 315-2590 Sea # Product Model, Number or Name Product Description 1 High Strength Concrete Lintels 4, 6, 8, and 12 inch wide lintels FL#158-RS Code Tvpe Versio Manufacturer _ Conta Revision 2014 CAST-CRETE USA, Inc. Craig Perrino Category. Structural Components (813) 621-4641 SubCategory: Products Introduced as a Result of cparrino@castcrete.com New Technology Compliance Method: Certification Mark or Listing FL#158-R8 Products Quality Assurance Approved for Use Approved for Use Impact Design Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 05/21/2016 Yes Yes NIA N/A Entity o Date Date pate Pendina Date Engineer & License Validated By Validated Submitted FBC Approval Approved Status Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 05/06/2016 04/29/2016 05/06/2016 Approved (786) 315-2590 Sea # Product Model. Number or Name Product Description 1 High Strength Concrete Lintels 4, 6, 8, and 12 inch wide lintels Quality Assurance Approved for Use Approved for Use Impact Desian Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 05/21/2017 Yes Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail FL#11383-R4 Code Entity or Tvpe Versio Man ufactu re Contact Enaineer & License Revision 2014 Powers Steel Inc. william powers Steven Schaub Category: Structural Components (802) 437-1160 PE-60509 SubCategory: Products Introduced as a Result of bill@powerssteel.00m New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#11383-R4 Products Sea # Product Model. Number or Name Product Oescription 1 PowerBOX8 Lintels Powers Steel Lintels are field assembled consisting of preformed steel lintels combined with brick or concrete masonry units, grout, and steel reinforcing bars. Validated By SAMUEL A. GREENBERG, RE, (813) 645-0166 Page 1 of 1 1192017 Date Date Date Pending Date Validated Submitted FBC Approval Approved Status 03/26/2015 03/23/2015 03/30/2015 06/22/2015 Approved Quality Assurance Approved for Us Approved for UsIm ac Desi gn Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 01/01/2017 No Yes N/A N/A N N � U 0 _ S_ a) C 0-0 CB -0 .6) UU--SS C N p U O '� C 3_ N 0 0 LL. fO CU � - � E �" 0 Q z z W J 1 SHEET NC PA 11111