L WOM SHALL COMPLY WITH ALL
REAMING CODES, FLORIDA EUILDINIG PR 2 1
cr�-v OF � --- ?0�4
CQ NXT ! E1_r C CODE AND � R
C11111MUMMI, t-smhNANC-S p JEXA
GENERAL MOTES CONSTRUCTION NOTES SYi" 50L LEGEND BUILDING CODE INFO °IATION INDEX OF DRAWINGS
I. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITION OF THE NATIONAL FIRE CODE 'FLORIDA BUILDING I. INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILING SHALL BE IN ACCORDANCE WITH ASTM E84. APPLICABLE CODES t STANDARDS: MEANS OF EGRESS: TI TITLE SHEET
CODE;' "FLORIDA MECHANICAL CODE," "NATIONAL ELECTRICAL CODE," AND ALL OTHER APPLICABLE LOCAL, STATE, ALL FINISH MATERIALS SHALL MEET A CLASS "B" INTERIOR FINISH RATING IN EXIT AND EXIT ACCESS AREA, x
AND FEDERAL CODES AND ORDINANCES, AND ALL AUTHORITIES HAVING LOCAL JURISDICTION. CLASS "C" ELSEWHERE. xx THE FLORIDA BUILDING CODE, 2010 EDITION FBC - BUILDING, CHAPTER 10 Al FLOOR PLAN / DETAILS
• BUILDING • EXISTING BUILDING MAXIMUM FLOOR AREA PER OCCUPANT A2 FIXTURE / GRAPHICS PLAN AND DETAILS
2. ALL EXIT DOOR5 SHALL BE OPERABLE FROM THE EGRESS SIDE WITHOUT THE U5E OF A KEY, TOOL, PLUMBING • ELECTRICAL TABLE 1004.1.1: 30 SF
2. THE GENERAL CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT EDITION OF THE SPECIAL KNOWLEDGE OR EFFORT. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS SHALL BUILDING SECTION . MECHANICAL 3,501 SF 121 PERSONS A3 INTERIOR ELEVATIONS
"GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" AIA DOCUMENT A201. NOT BE USED. SYMBOL
• 2012 FLORIDA ACCESSIBILITY CODE FOR EGRESS WIDTH PER OCCUPANT - TABLE 1005.1 I01 FINISH FLOOR PLAN AND DETAILS
3. THE CONTRACTOR SHALL, UPON DISCOVERY, GIVE WRITTEN NOTICE TO THE ARCHITECT OF ANY MATERIALS, 3. ALL GLAZING WITHIN A 24 INCH ARC OF DOORS WHOSE BOTTOM EDGE IS LESS THAN 60 INCHE5 ABOVE IBUILDING CONSTRUCTION 121 x 0.2 25.4"
EQUIPMENT, OR DE51GN FEATURES WHICH HE BELIEVES TO BE INADEQUATE OR UNSUITABLE, IN vIOLATION OF LAWS, THE FLOOR AND GLASS BELOW 18" AFF. AND ALL GLAZING IN DOORS SHALL BE SAFETY GLASS, x
ORDINANCES, OR RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION OVER THE WORK, AND OF TEMPERED GLA55 OR ACRYLIC PLASTIC SHEET PER FBC-240II FLORIDA FIRE PREVENTION CODE 2010 EDITION NI ARCHITECTURAL SPECIFICATIONS
ANY NECE55ARY ITEMS OR WORK OMITTED FROM THE DRAWINGS. xx NFPA 101 LIFE SAFETY CODE FLORIDA EDITION
4. OBJECTS PROTRUDING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 21" AND W" ABOVE THE WALL SECTION NATIONAL ELECTRICAL CODE 2008 EDITION El ELECTRICAL SPECIFICATIONS AND LEGEND
4. ALL SUBCONTRACTORS SHALL USE ONLY SKILLED CRAFTSMEN, EXPERIENCED IN THE WORK OF THEIR TRADE, FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, SYMBOL 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AL -LOW. PROVIDED
TO ENSURE FIRST CLASS WORKMANSHIP.' ANY WORK NOT EQUAL TO BEST TRADE STANDARDS SHALL BE REMOVED OR AISLES. OBJECTS MOUNTED AT OR BELOW 21" ABOVE FINISHED FLOOR MAY NOT PROTRUDE ANY MIN. CLEAR DOOR OPENING - 1006.1.1 32" 2 32" E2 ELECTRICAL LIGHTING PLAN AND
AND REPLACED AT NO ADDITIONAL COST. SHOULD ANY SUBCONTRACTOR REFUSE TO REMOVE AND REPLACE AMOUNT. FREE STANDING OBJECTS MOUNTED ON POST OR PYLONS MAY OVERHANG 12". PROTRUDING MIN. CLEAR STAIR WIDTH - 100e.1 44" 44" SCHEDULES
UNSATISFACTORY WORK, THE CONTRACTOR MAY REMOVE AND REPLACE IT, AND CHARGE THE COST TO THE OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. x COMMON PATH OF TRAVEL - 1014.3 15 FT <15 FT E3 ELECTRICAL LIGHT STAT DETAILS
OCCUPANCY CLASSIFICATION: EXIT ACCESS TRAVEL DIST. - TABLE 10111 150 FT < 150 FT
SUBCONTRACTOR 5. PROVIDE DEADWOOD BLOCKING WITHIN WALL CAVITIES AT LOCATIONS INCLUDING, BUT NOT xx MIN. CORRIDOR WIDTH - 10182 44" 2 44"
LIMITED TO, WALL MOUNTED CABINETRY, FIRE EXTINGUISHER CABINETS, TOILET ACCESSORIES, GRAB BARS, DETAIL FBG - BUILDING, CHAPTER 3 DEAD END CORRIDOR - 1018.4 20 FT <20 FT
5. IT 15 THE GENERAL CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE WALL STOPS, ETC- 18GA. GALV. FLAT METAL MAY BE USED IN LOCATIONS APPROVED BY ARCHITECT. SYMBOL SECTION 309: MERCANTILE OCCUPANCY - GROUP M (UNSPRINKLERED) MIN. NUMBER OF EXITS - 1021.1 / 1021.2 2 3
TO ENSURE THE SAFETY OF PEOPLE AND OF THE BUILDING AND ITS COMPONENT PARTS DURING CONSTRUCTION. 6. ALL RATED PARTITIONS SHALL EXTEND FROM THE TOP OF THE FLOOR TO THE CEILING AND BE SECURELY
THIS INCLUDES, BUT 15 NOT LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING OR TIE DOWNS THAT CLASSIFICATION OF WOR�G
MAY BE NECESSARY, SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE ATTACHED THERETO. WHERE SAID CEILING IS NOT PART OF AN ASSEMBLY HAVING A FIRE RESISTANCE x NUMBER AND SIZE OF EXITS
CONTRACTOR AFTER COMPLETION OF THE PROJECT. RATING AT LEAST EQUAL TO THAT REQUIRED FOR THE PARTITION, THE PARTITION SHALL BE xx FEBC - EXISTING BUILDING SECTION 403 ENTRANCE DOORS 68' x 1 68"
CONSTRUCTED TIGHT AGAINST THE FLOOR OR THE ROOF DECK ABOVE. � DETAIL ALTERATION LEVEL 1 TENANT EXIT DOORS 34 x 1 34
"
6. ALL PRODUCTS AND PARTS SHALL FIT TOGETHER NEATLY, WITHOUT DAMAGE OR DISFIGUREMENT. EXCEPT FOR 1. PENETRATION OF FIRE RATED WALLS FOR ELECTRICAL, TELEPHONE, PLUMBING, l SYMBOL 46" x 1 46TOTAL EXIT WIDTH 148"
SPECIFIED CURVED SURFACES, ALL PRODUCTS AND PARTS SHALL BE CONSTRUCTED/ FABRICATED AND INSTALLED HY.A.C. DUCTS, COMMUNICATION SYSTEMS OR SIMILAR FACILITIES SHALL BE `r.J HEIGHT AND BUILDIW= AREA: IEXISTINCs�
TRUE, IN LINE, AND PLUMB. ALL NON CONFORMING WORK SHALL BE REJECTED AND RE -ACCOMPLISHED BY THE PERMITTED BY NON-COMBUSTIBLE PIPE OR CONDUIT WHEN ALL OPENINGS AROUND THE PIPE OR
GENERAL CONTRACTOR AT NO ADDITIONAL COSTS TO THE OWNER. CONDUIT ARE FIRESTOPPED WITH APPROVED NON-COMBUSTIBLE MATERIALS OR WHEN THE FBC - BUILDING, CHAPTER 5: TYPE 11-5, UNSPRINKLERED SPACES WITH SINGLE EXIT - -
PENETRATION IS PROTECTED WITH A SYSTEM WHICH HAS AN "F" RATING EQUAL TO OR GREATER THAN 0'-0" ELEVATION MARK AREA MODIFICATION FOR FRONTAGE INCREASE - 501 0.00% TABLE 1015.1 / 1021.2 N/A
1. ALL WORK SHOWN ON THE DRAWINGS SHALL BE CONSTRUCTED OF NEW COMPONENTS. THE ASSEMBLY IN WHICH THE PENETRATION OCCURS. AREA MODIFICATION FOR AUTOMATIC SPRINKLER SYSTEM - 5063 0.00r
TOP OF SLAB INTERIOR FINISHES:
8. ALL BIDS SHALL BE PREPARED FROM A COMPLETE SET OF CONSTRUCTION DOCUMENTS, COMPLETE SETS OF 8• PROVIDE AND INSTALL PORTABLE FIRE EXTINGUISHERS AS SHOWN IN THESE DOCUMENTS ALLOWED PROVIDED
DOCUMENTS SHALL NOT BE BROKEN UP FOR BID PURPOSES. SUCH ACTION MAY RESULT IN A LACK OF OR AS OTHERWISE DIRECTED BY THE LOCAL FIRE MARSHAL. TABLE 503: HEIGHT AND BUILDING AREA FBG - BUILDING, CHAPTER 8 BUSINESS - GROUP M (UNSPRINKLERED)
INFORMATION IN REFERENCE TO THE SCOPE OF WORK TO BE PERFORMED. (3. SIGNAGE SHALL BE PROVIDEDNTERIOR ELEVATION INTERIOR WALL AND CEILING FINISH REQUIREMENTS - TABLE 803.`3
AS REQUIRED AND AS STATED IN THE 2012 FLORIDAFLORIpA ACCESSIBILITY CODE x/A MARK MAXIMUM BUILDING HEIGHT 55' +/- 24'-0" VERTICAL EXITS AND EXIT PASSAGEWAYS: GLASS A
FOR BUILDING CONSTRUCTION AND SHALL COMPLY WITH CHAPTER 1 SECTION 103 SIGNS. MAXIMUM STORIES 2 I EXIT ACCESS CORRIDORS / EXITWAYS: CLASS B
9. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO PERSONALLY FIELD INSPECT THE PROJECT SITE AREA PER FLOOR 12,500 SF 3,501 SF ROOMS AND ENCLOSED SPACES: CLASS C,10. THE HVAC CONTRACTOR SHALL START AND TEST ALL EXISTING AIR CONDITIONING EQUIPMENT TO BE
PRIOR TO THE PREPARATION AND SUBMITTAL OF HIS BID. THI5 INSPECTION IS REQUIRED 50 THAT THE REU5ED PRIOR TO OR AT THE EARLIEST ONSET OF CONSTRUCTION TO ASSURE 5Y5TEM5 ARE FUNCTIONING KEYED DRAWING CONTRACTOR SHALL BE TOTALLY FAMILIAR WITH THE EXISTING CONDITIONS AND THEIR INTERFACE WITH THE NEW OPTIMALLY. ANY DEFICIENCIES, MAINTENANCE OR REPAIRS THAT ARE REQUIRED FOR SYSTEM(S) TO RUN NOTES 3,Sml SF INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN®��T
SCOPE
CONSTRUCTION AS DEFINE[) IN THESE CONSTRUCTION DOCUMENTS. PROPERLY SHALL BE PRESENTED TO THE GENERAL CONTRACTOR IMMEDIATELY IN WRITTEN LINE -ITEM ACCORDANCE WITH ASTM E 84.
10.UNLE55 OTHERWISE SPECIFIED, THE G.C. SHALL FURNISH A WRITTEN GUARANTEE FOR ALL WORK (EQUIPMENT, FORM FOR PRESENTATION TO THE OWNER FOR REVIEW. 000 DOOR NUMBER SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE INSTALLED IN
SYMBOL CONSTRII.ICTION TYPE: (EXISTINCs)
MATERIALS, AND LABOR), AGAINST ANY DEFECTS IN SAID WORK FOR A PERIOD OF ONE (1) YEAR FROM THE DATE 11. THE GENERAL CONTRACTOR SHALL INSPECT THE EXISTING ROOF PRIOR TO CONSTRUCTION TO A55URE THAT ACCORDANCE WITH THE PROVISIONS OF ASTM C 63D AND ASTM C 636.
OF SUBSTANTIAL COMPLETION, WITH ALL APPROPRIATE REPAIRS OR REPLACEMENTS AT NO ADDITIONAL COST IT 15 WATER TIGHT. ANY DEFICIENCIES, MAINTENANCE OR REPAIRS TO BRING IT UP TO OPTIMUM CONDITION FBC - BUILDING, CHAPTER 6 INTERIOR BUILD -OUT FOR MATTRESS FIRM WITHIN AN EXISTINCx
TO THE OWNER SHALL BE PRESENTED IN WRITTEN LINE -ITEM FORM FOR PRESENTATION TO THE OWN ROOMNUMBER TABLE III - FIRE RESISTANCE RATING FOR BUILDING ELEMENTS MATERIAL, OTHER THAN FOAM PLASTIC USED AS INTERIOR TRIM SHALL HAVE SINGLE STORY RETAIL CENTER.
000 A MINIMUM GLASS C FLAME SPREAD AND SMOKE -DEVELOPED INDEX WHEN
BREQ'D PROVIDED
11. IT SHALL BE THE RESPONSIBILITY OF THE G.C. AND/OR CONTRACTORS TO COMPLY WITH ALL THE SYMB
OL STRUCTURAL FRAME INCLUDING TESTED IN ACCORDANCE WITH ASTM E 54. ALL EXTERIOR SIGNAGE PACKAGES TO BE SUBMITTED UNDER
REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1510 BY THE U.S. DEPARTMENT OF LABOR, BEAMS, COLUMNS, GIRDERS, TRUSSES 0 HR 0 HR SEPARATE PERMIT.
x WINDOW BEARING WALLS, EXTERIOR 0 HR 0 HR INTERIOR WALL SURFACES WITHIN l2) TWO FEET OF URINALS AND WATER
AND REQUIRE ALL ITS SUBCONTRACTORS AND EMPLOYEES TO COMPLY WITH THIS LAW, AND ANY RELATED STATE RSPONSISIL ITY SChI1DU1 O SYMBOL BEARING WALLS, INTERIOR 0 HR 0 HR CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO A MECHANICAL AND PLUMBING SYSTEMS ARE EXISTING TO
OR LOCAL LAWS. HEIGHT OF (4) FOUR FEET ABOVE THE FINISHED FLOOR MINIMUM. THE
NONBEARING WALLS, INTERIOR 0 HR 0 HR MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT REMAIN. NO WORK IS REQUIRED.
12. THE DATA GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED. THEIR A55OLUTE ACCURACY GENERAL CONTRACTOR MATTRE55 FIRM FLOOR CONSTRUCTION INCLUDING ADVERSELY AFFECTED BY MOISTURE.
SUPPORTING BEAMS d JOISTS 0 HR O,HR
IS NOT GUARANTEED, AND THE G.C. SHALL OBTAIN EXACT LOCATIONS, MEASUREMENTS, LEVELS, ETC. PRODUCT PURCHASED INSTALLED PURCHASED INSTALLED X ROOF CONSTRUCTION INCLUDING
AT THE SITE AND SHALL 5AT16FACTORILY ADAPT HIS WORK TO THE ACTUAL CONDITIONS OF THE BUILDING. DO NOT CARPET (C-U • • REVISION SUPPORTING BEAMS 4 JOISTS 0 HR 0 HR
SCALE PRINTS. VERIFY ALL DIMENSIONS WITH THE ARCHITECT PRIOR TO COMMENCING WORK
PORCELAIN TRACK (FF-1) 0 • �, I MAP
13.THESE DOCUMENTS AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE ALTERED IN ANYWAY BY VCT (VCT-I, VCT-2) • • TABLE 602 - FIRE RESISTANCE RATING FOR EXTERIOR WALLS BEARING OJ ..�"t TEAM LOCATIOI�I f•�i1-
THE CONTRACTOR OR THE OWNER ALTERATIONS SHALL BE MADE ONLY BY THE ARCHITECT OF RECORD. FRP (FRP U • • AND NON BEARING BASED ON FIRE SEPARATION DISTANCE �/
RUBBER BASE (RB-I) • • LESS THAN 5' 1 HR N/A
FLOOR TILE (FT-1) • • 1 HR N/A ARC44ITECT
BASE TILE (FBT-1) ® ® 0 HR N/A OLIVERI ARCHITECTS
20' TO 30' 0 HR N/A 32101 U.S. HWY.19
FLOOR TRANSITIONS • • 30' AND OVER 0 HR N/A
SWITGHGEAR • • C3 WALL TYPES 5' TO 10' PALM HARBOR, FLORIDA 34684
10 TO 20 121-181-1525
DOOR HARDWARE • �1
INTERIOR LIGHTING • • ELECTRICAL
GRAPHICS • • 2 MICELA s• "€
FIRE RESISTANCE (EXISTING) 240PINE AVE N
Hvac • • OLDSMAR, FLORIDA 34611 " PROJECT
EXTERIOR SIGNAGE • • KEY PLAN FBG - BUILDING, CHAPTER 1 REQ'D OPENING 813-855-2121 SITE
CEILING TILES (AC-1) • • SECTION SYMBOL FIRE BARRIER ASSEMBLY PROTECTION
(TABLE 115.4)
PAINT • •
FIRE WALL - 7011 AND TABLE 106.4 N/A
RACK STORAGE • • SHAFT / EXIT ENCLOSURES - 105.4 / 1018.1 i
a
PLUMBING FIXTURES / GRAB BARS • • LESS THAN 4 STORIES 1 HR I HR
OCCUPANCY SEPARATION-1013.8 / 506.4 N/A
SPRINKLER SYSTEM • • TENANT SEPARATION - "i 1 HR I HR
WATER SUB -METER • • EXIT PASSAGEWAY - 10133 / 1022.1 N/A -
AD DISPLAY BOARD • • HORIZONTAL EXIT - 1073.4 / 1025.1 N/A -
SINGLE OCCUPANCY FIRE AREA - 1013-e N/A -
VALUE ZONE PLATFORM • • CORRIDORS (OCCUPANT LOAD > 30) - 1015.1
DISPLAY TOWER • • (UNSPRINKLERED) N/A -
CUSTOMER SERVICE DESK • •
LIGHTSTAT • •
RE14SIONS BY
I ,
00
M
4-- N
/ � x ti vUUi
�� C Lw Y
O C L
rn 0 o
3 r- 3
cti .
E a
N
r
w
U E cn
�zW�W
o_ Q,�x
0
Ga a. P4 0
O O r4 �i
o
CQ
i;
0
=� o
j d "r
L O
O
o #
v
f° c
O
C
(f)
L
O
O
U
o rn
M
a � M
O o Z3 J
(n N m
li] LLJ O
O S
E
E t
00
O O CIO
IV
L
a
N
IV
Date: 02. 06, 14
Scale: AS NOTED
Project Mgr: LCH
Drawn: JDR
Job: 12-194
Sheet
T1
H:\Projects\Projects 2012\12194 - M.F. Zephyrhills, FL - Zephyrhills\04-CD\01-CD.A\04-Architechrral\OTI-TITLE.dwg, 2/7/2014 8:40:07 AM, LCM
WALL LEGEND
3/8" PORCELAIN PLANK TILE AND
SETTING AS SPECIFIED
LINE: OF WALL BEYOND
3/4" PLYWOOD SUBSTRATE
3'-6"
E/2 G.W.B.
J
METAL 5TUD5 AT
EXISTING DOOR SYSTEM
EXISTING CONCRETE SAWCUT CONCRETE SLAB MIN.
1/4" OURA50ND
3 _4 11
Iro" D.G. SEE
WALLTYPES.
i
1 x 4 (NOM.) FACE
® EXISTING WINDOW SYSTEM
SLAB 1 1/2" DEEP AND BREAK OUT
FLUSH
TRIM50ARD j
EXISTING CONCRETE
SCHLUTER-RONDEC TRIM WITH CLEAR
AS PER WALL TYPE
1/2" GYPSUM
PAINTED i i
EXISTING INTERIOR PARTITION
3000 PSI CONCRETE INFILL
ANODIZED ALUMINUM FINISH, 3/8"
CONTINUOUS 2x4 WOOD BLOCKING
WALLBOARD
j
EXISTING EXTERIOR WALL SYSTEM
RADIUS - BY TENANT
```'
OWNER PROVIDED MOUNTING BRACKET
EXISTING ONE (1) HOUR RATED SEPARATION PARTITION
FLUSH`
j"
3/8" PORCELAIN PLANK TILE AND
�i
PORCELAIN PLANK TILE AS
2x WOOD BLOCK
i"
a
SETTING AS SPECIFIED
SCHEDULED ON TOP AND FRONT OF
PLATFORM SECURED BY DURABOND
_'�
V//z
i
a a `, i
1/4" DURABOND
TO PLYWOOD SUBSTRATE _
3/4" PLYWOOD SUBSTRATE
F
"POPLAR" WOOD
�
i �i� \•.
2X4 P.T. BLOCKING AS REQUIRED
3/4" FIELD 3/4" TRIM TO MATCH
_ (k
°
fi
VERIFY DOOR FRAME
PROFILE
6,
PROVIDE A MIN ' CEMENT
VAPOR BARRIER <, �` ` STABILIZED
"
GENERAL NOTES:
CONT. 2x4 P.T. WOOD STUDS
VA
�`j
EQUIVALENT TO ' , , ",i� j, j ,;/ SAND
STEGOWRAP BELOW
1. WOOD FRAMING AND SUBFLOOR AT VALUE ZONE
NEW CONCRETE - TAPE ` ` ' \.
`\ � �\ \,`
PLATFORM SHALL BE FIRE RETARDANT TREATED
GENERAL NOTE:
WOOD FRAMING AND SUBFLOOR AT
WALL SYSTEM -
, i ; � , rF,�\
NEW VAPOR BARRIER r \ j r� j j\ j NEW PLUMBING
TO
2. PORCELAIN PLANK TILE AND PORCELAIN PLANK BASE
VALUE ZONE PLATFORM SHALL BE
SEE FLOOR PLAN
EXISTING. PIPING OR
TO BE INSTALLED WITH 1/4" BACKER BOARD SECURED
FIRE: RETARDANT TREATED
CONDUIT AS
WITH DURABOND
PROVIDE CLEAN COMPACTED REQUIRED
TERMITE TREATED FILL AS REQUIRED
r1
O%SAW
CUT/ SLR IDATC 4 DETAIL
SCALE: 3" = I'-0"
O
DETAIL AT VALUE ZONE PLATFOW
O
SECTION AT VALUE ZONE PLATFORM
O
WOOD CASED OP�NINCa .
SCALE: I'-0"
O
SECTION AT TRIM80Ar%w
SCALE: 3" 1'-0"1rD
NOTES
SCALE: 3" = 1'-0"
SCALE: 1" = 1'-0"
3" =
=
DOOR SCE-IEDULE ®
O1 EXISTING CONCRETE SIDEWALK
O2 EXISTING EXTERIOR WALL SYSTEM.
a
fit'
t
3� EXISTING STOREFRONT WINDOW SYSTEM.
NO.
TYPE
DIMENSIONS
CONSTRUCTION
N
w
v
Q
_
o
ik
ca
4
O EXISTING STOREFRONT DOOR SYSTEM.
SIZE
DOOR
FRAME
a
OEXISTING STOREFRONT DOOR SYSTEM TO REMAIN CLOSED AND
LOCKED.
O EXISTING ELECTRICAL PANEL - SEE ELECTRICAL DRAWINGS.
O WALL MOUNTED FIRE EXTINGUISHER
OS EXISTING PLUMBING FIXTURE.
101a
-
EXISTING
-
-
-
-
-
-
-
-
-
-
-
13,Sb
I01b
-
EXISTING
-
-
-
-
-
-
-
_
_
_
1235b
101C
-
EXISTING
-
-
-
-
-
-
-
-
-
-
-
135(,1
1
26
103
-
EXISTING
-
-
-
-
-
-
-
-
-
-
-
13,4
18
2
1
1
O LINE OF FLOOR FINISH - SEE SHEET ID1 FINISH FLOOR PLAN.
10 EXISTING PHONE BOARD - SEE ELECTRICAL DRAWINGS.
II EXISTING FRP-1 VENEER OVER EXISTING GWB (FIELD VERIFY).
PROVIDE IF NOT PRESENT.
104
-
EXISTING
-
-
-
-
-
-
-
13,4
— — — — - — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — —
- - - - - - - 21
30 -
0
21
106a
-
EXISTING
-
-
-
-
-
-
-
-
-
-
-
13,4
1obb
-
EXISTING
-
-
-
-
-
-
-
-
-
13Sb
REMARKS
I. EXISTING DOOR - VERIFY ALL HARDWARE IS PROVIDED AND IN WORKING ORDER
29
r
1
0,
000
12 EXISTING FLOOR SINK
RE -KEY AS REQUIRED.
3
1
00
0°0°
0EXI5TING ELECTRIC WATER HEATER ABOVE.
2. A SIGN READING "THIS (OR THESE) DOORS) SHALL REMAIN UNLOCKED DURING
HOURS"
9
1
3
00
0°0
°o°o
14 VALUE ZONE PLATFORM - SEE DETAIL C/AI.
BUSINESS ON THE INSIDE FACE OF DOOR. SIGN SHALL CONSIST OF ONE INCH
(1") HIGH BLACK LETTERS MOUNTED AT 5'-0" AFF.
1
-
ie 0
o oG
15 LIGHTSTAT HVAC CONTROL PANEL - SEE ELECTRICAL DRAWINGS.
3. ALL DOOR HARDWARE AND ITS OPERATION SHALL COMPLY WITH A.D.A AND ANY
STATE OR LOCAL SHALL
i6 M
16 LIGHTSTAT LIGHTING CONTROL PANEL -SEE ELECTRICAL
O
CODES, G.G. COMPLY WITH THE M05T STRINGENT.
18
DRAWINGS.
4
4. DOOR AND DOOR FRAME TO BE PAINTED WITH SEMI -GLOSS ENAMEL OF THE SAME
Il 30„ HIGH CUSTOMER SERVICE DESK BY TENANT INSTALLED BY
COLOR AS THE WALL ON WHICH THE DOOR IS INSTALLED. (UNLESS OTHERWISE NOTED)
9
CONTRACTOR VERIFY ALL EXISTING REQUIRED ELECTRICAL
5. REPLACE EXISTING CYLINDER WITH A NEW CYLINDER KEY OUTSIDE AND THUMB TURN
29
3/A3
UNDERGROUND ROUGH -IN. SEE DETAILS SHEET A2.
INSIDE.
I
18
,
18 EXISTING AWNING SYSTEM ABOVE.
6. PROVIDE NEW WEATHER STRIPPING.
iA
1
19 EXISTING ELECTRIC HI-LO DRINKING FOUNTAIN.
1. DOOR TO REMAIN CLOSED AND LOCKED.
29
IN
22 rE
�
I1
g
_ -
0SAW CUT CONCRETE SLAB AS REQUIRED FOR NEW ELECTRICAL
2
2
WORK PATCH AND REPAIR CONCRETE SLAB AS REQUIRED TO
MATCH AND ALIGN WITH EXISTING - SEE DETAIL E/A1.
----- -
METAL GUIDES PROVIDED BY TENANT, INSTALLED BY
0/�/�
/�
DOOR GENE Ip AL NOTES
18
30
3 i
CONTRACTOR .
23
22 EXISTING STRUCTURAL COLUMN - BOX -OUT WITH 1/2" G.W.B. OVER
METAL STUD FRAMING AS REQUIRED. KEEP SIZE TO MINIMUM.
1. ALL DOORS/DOOR OPENINGS SHALL COMPLY WITH FLORIDA FIRE PREVENTION CODE
3 SHOWROOM
-
25
/[0
23 HANGING GRAPHIC SUPPLIED BY TENANT, INSTALLED BY
2010 EDITION / NFPA 101 LIFE SAFETY CODE
101
C
4
CONTRACTOR
1.2.1.2 WIDTH
1.2.1.4 SWING AND FORCE TO OPEN
ei
24 WOOD CASED OPENING - SEE DETAIL 5/A1.
18
`�
1.2.1.5 LOCKS AND LATCHES AND ALARM DEVICES
12.1.6 SPECIAL LOCKING ARRANGEMENTS
q,
25 LOCATION OF ELECTRICAL POWER AND DATA CONDUIT STUB -UP
1.2.1.1 PANIC HARDWARE AND FIRE EXIT DEVICES
A �q
v
18
FOR FUTURE TENANT'S USE - SEE ELECTRICAL DRAWINGS.
1.2.1.5 SELF CLOSING DEVICES
5
26 EXISTING TENANT - NO WORK IN THIS AREA.
2. ALL DOOR HANDLES SHALL BE LEVER TYPE MEETING A.D.A. REQUIREMENTS.
g
1
1'-I0" 3'-0" 18'-i0" +/-
11'-0" 12'-0" +/- 3'-0" 1'-10"
21 EXISTING ONE (1) HOUR RATED SEPARATION PARTITION - MAINTAIN
3. ALL DOORS WITH AUTO CLOSERS SHALL HAVE BALL BEARING TYPE HINGES
2-3
3
INTEGRITY DURING CONSTRUCTION.
3
4. DOOR CLOSER SHALL BE INSTALLED SUCH THAT THE SWEEP PERIOD OF THE CLOSER
20 28 _
20 28
28 ELECTRICAL FLOOR OUTLETS -SEE ELECTRICAL DRAWINGS
SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 10•, THE DOOR WILL TAKE
AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES (16MM) FROM THE LATCH,
18
?
I
29 EXISTING CONCRETE CURB.
MEASURED TO THE LEADING EDGE OF THE DOOR.
1/a3
29
--
30 EXISTING LANDSCAPE AREA.
5. THE MAXIMUM FORGE FOR PUSHING OR PULLING AN INTERIOR DOOR SHALL BE 511bf
(222N) AND THE MAXIMUM FORCE FOR PUSHING OR PULLING AN EXTERIOR DOOR
2
r v
SHALL NOT EXCEED 8.5L5F (31BN).
6. PROVIDE EITHER WALL OR FLOOR STOPS FOR ALL DOORS AS REQUIRED.
g
----------
1. EXISTING INTERIOR DOORS TO BE CLEANED, LIGHT SANDED, AND SEALED / PAINTED
18
to
30
-
AS REQUIRED.
-----
r—i —
I I 3�_0,, 7
i
I
24 `\ I I
/�
3 s3 i/ WOMEN
I
Al)
I
GENERAL NOTES
15 in` 1 8 / -----
FE�
3
Li
1. CONTRACTOR TO PROVIDE ADDITIONAL STOCK OF FINISH MATERIALS
I
i
066 PILES / ---- D� o ----- ZONES
RECORDS rtl \/ cn
(�
\
r 0 1
4 I I 102
1 9
AT COMPLETION OF WORK
4 106
10 VESTjBULE
2. ITEMS PROVIDED TO TENANT BY GC TO INCLUDE:
3 105 ----- %6TA3 F_____� 14
1/A3
i 18
- (1) GALLON OF PAINT (ALL COLORS)
�
18
1 \
II rq I I I
T� -i r
2 13 6 �h.I___T__ I '-
- (1) BOX OF EACH LIGHT FIXTURE REPLACEMENT BULBS
- (1) BOX OF TILES, LAMINATE, VGT
L
12 16 y 9 `\ 1041 / -------
----------
30
3. PLACE ALL ADDITIONAL STOCK IN AVAILABLE STORAGE AREA.
4. ALL CEILING AND LIGHT FIXTURES ARE EXISTING.
L-- ___
--!
ii
29
1
5. ALL HVAC SYSTEMS ARE EXISTING.
I
I
6. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS ON SITE AND NOTIFY
2 2 30
2 3
2
ARCHITECT WITH ANY DISCREPANCIES UPON DISCOVERY PRIOR TO
PROCEEDING.
1. ALL INTERIOR WALLS ARE EXISTING AND PROVIDED BY LANDLORD.
29
29
PREPARE TO RECEIVE NEW WALL FINISHES, AS REQUIRED.
8. PATCH 4 REPAIR EXISTING CONCRETE SLAB AS REQUIRED. FLOAT
OVER OR PROVIDE COMPLETE OVER LAY IF NEEDED. PREPARE TO
RECEIVE NEW FINISHES.
PLAN
OFLOOR
j
3,801 5Q. FT.
SCALE: 3/16" = I'-0"
REVISIONS BY
y 00
<r
�^
N
Q
0
N c1l I V
�- tiy
C cad N
C' cd y
o c
Q : • t` j
Q' E
Q p O
0
O
y 3 ti 3
-� ox`\' .
U
V�D
Eo~p
ti a
N
r
A
"j.
P04...E- '
O:5
o
c�
N
-b V
o
• ct, �
4 d
o �
b �
6 °
..a
L
t
C
N
U
L L e--
°
0 lf)
M
O 0 J
•� v , (n — to
m w C _
0 s
•° I— E0s
a) Q ° 00 a
U N N
t
a
Q
N
Date: 02, 06. 14
Scale: AS NOTED
Project Mgr: LCH
Drawn: JDR
Job: 12-194
Sheet
Al
H:\Projects\Projects 20l2\12194 - M.F. Zephyrliills, FL-Zephyrhills\04-CD\01-CD.A\O4-ArcMtechtral\AI-FLPL.dwg, 2/7/2014 8:40:02 AK L.CM
MATTRESS FIRM - Gi APH I CS OSDI E R:
PART
NO.:
LOCATION:
QTY.
PART
NO. :
LOCATION
QTY.
CENTER TOWER
WALL GRAPHICS
CT01
LADY GRAPHIC
_
WALL02
FIRM GUARANTEE LIFESTYLE GRAPHIC
8
CT015MALL
LADY GRAPHICS (5MALL)
_
WALL02A
FIRM GUARANTEE LIFESTYLE GRAPHIC (NO FRAME)
-
CT01Hang5m
HANGING CURVED LADY GRAPHIC
-
WALL025
FIRM GUARANTEE LIFESTYLE GRAPHIC (NO FRAME)
-
CT01HangLg
HANGING CURVED LADY GRAPHIC
1
WALL02C
FIRM GUARANTEE LIFESTYLE GRAPHIC (NO FRAME)
-
CT02
MATTRESS FIRM GRAPHIC
_
WALL02D
FIRM GUARANTEE LIFESTYLE GRAPHIC (NO FRAME)
-
TOTAL:
i
WALL03
TEMPURPEDIC STAND-ALONE (SINGLE SIDED)
-
PART
NO.:
LOCATION:
QTY'
WALL03A
TEMPURPEDIC STAND-ALONE (SINGLE SIDED)
-
TEST AREA
WALL035
TEMPURPEDIC STAND-ALONE (SINGLE SIDED)
-
TA01
"A" VER51ON DISPLAY FIXTURE
-
WALL03C
TEMPURPEDIC STAND-ALONE (SINGLE SIDED)
-
TA02
1 (ONE) SIDED GRAPHIC
_
WALL03D
TEMPURPEDIC STAND-ALONE (SINGLE SIDED)
-
TA03
2 (TWO) SIDED GRAPHIC
_
WALL04
ALL THE BEST BRANDS (VINYL GRAPHIC)
I
TA04
CbyC OVAL GRAPHIC
-
WALL04A
ALL THE BEST BRANDS GRAPHIC (TEMPURPEDIC)
I
TA05
13" VERSION DISPLAY FIXTURE
_
WALL045
ALL THE BEST BRANDS GRAPHIC (SLEEP NUMBER)
I
TA06
I (ONE) SIDED GRAPHIC
-
WALL04C
ALL THE BEST BRANDS GRAPHIC (SEALY)
1
TA01
12 (TWO) SIDED GRAPHIC
I
WALL04D
ALL THE BEST BRANDS GRAPHIC (SIMMONS)
1
TA08
CbyC OVAL GRAPHIC
I
WALL04E
ALL THE BEST BRANDS GRAPHIC (SERTA)
-
TOTAL:
2
WALL04F
ALL THE BEST BRANDS GRAPHIC ([COMFORT)
-
PART
NO.:
LOCATION:
QTY.
WALL05
THANK YOU SIGN
I
WALL01
TEMPURPEDIC WALL GRAPHIC (FREE STANDING)
WINDOW GRAPHICS
WALL08
SLEEP NUMBER GRAPHIC (FREE STANDING)
-
WINSTART
WINDOW GRAPHICS STARTER SET (58" WIDE)
2
WALL09
TEMPURPEDIC BRUSHED LETTER (96" WIDE)
-
WINADDON
WINDOW GRAPHICS ADD ON SET
WALI-10
SLEEP NUMBER BRUSHED LETTERS (96" WIDE)
-
WALLII
TEMPURPEDIC BRUSHED LETTER (120" WIDE)
-
TOTAL:
2
WALL12
SLEEP NUMBER BRUSHED LETTERS (120" WIDE)
-
PART
NO.:
LOCATION:
QTY.
WALL13
STORE HOURS
-
WINDOW GRAPHICS
WALL15
MATTRESS FIRM REAR DOOR PI=CALS
1
"A" VERSION
WALL20
SNAPLOCK COMMUNITY SIGN SYSTEM
1
SPA01
ENTRY SIGN
-
WALL21
COMFORT BY COLOR DIRECTIONAL CEILING GRID SIGNS
1
6PA02
FOREST WALL GRAPHIC
-
TOTAL:
11
SPA03
(3) GRAPHICS: LADY/FOAM/AIR
-
PART
NO.:
LOCATION
QTY.
5PA04
WALL WORDS
-
CLEARANCE CENTER GRAPHICS
"B" VERSION
CC01
HOW TO BUY
-
5PA01
ENTRY SIGN
_
CCO2
THIS MONTH (LARGE)
-
SPA02
FOREST WALL GRAPHIC
-
CC04
MONTH NUMBERS
-
SPA03
REFRESH WALL GRAPHIC
-
CCO5
SEALY CLEARANCE CENTER
-
TOTAL:
-
CC06
NOBODY SELLS SEALY FOR LESS
-
PART
NO.:
LOCATION:
QTY
CC01
ASK SIGN - KING
-
VALUE ZONE
CC08
ASK SIGN - QUEEN
-
CC09
ASK SIGN - FULL
-
VZ01
VALUE ZONE (HEADER)
I
CCIO
ASK SIGN - TWIN
-
vZ02
VALUE ZONE (LOGOS)
1
CC11
DELIVERY POLICY
-
GM09
5FT LONG VALUE ZONE BED DIVIDER FIXTURE
4
CC12
NEED A HAND
-
TOTAL:
6
CC13
e999 SIGN
-
PART
NO.:
LOCATION:
QTY.
CC13A
I THIS MONTH SIGN (REPLACEMENT GRAPHIC)
-
TOTAL:
NEW HEADBOARDS
SPECIAL REQUESTS:
H501
TEMPURPEDIC HEADBOARD SHORT
_
H502
TEMPURPEDIC HEADBOARD TALL
TOTAL.:
-
EDGE OF
FLOOR TILE m"
3� V
V
�Q
TOP
_
DESK
S
30" A.
F.
m
c�
F
W
'
r
�
I
I
I
4
WANGING
ELECTRhAL
EE
(
BOVE
l •
0
— — --
3"
WIRE
—
—
v
GROMMETS,
rr1
I
�
I
I
�
I
I
L
m
-
ry
r
iv
A
GICUSTOMER 3E%YICE DES 00 PLAN
SCALE: 1/2" = 1'-0"
EDGE OF
FLOOR TILE
CENTER OF QUAD
RECEPTACLE TO BE
MOUNTED 2' AFF.
I
I
I
I
I
I
I
r-----_----
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
i
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
L---------
r
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
L
101 CUSTOMER SEMY ICE DESK ELEVATION � �IXTUi�E / C�iZ4I=HICS LA` MT PLAN
11 __.....
s�
l�
_° 1=
0
_ ..:
is
? 1
WALL v02
PILES /
RECORDS
106
AIWA CALCULATIONS
1
ROOM NO.
ROOM NAME
AREA NAME
AREA
(SQUARE FEET)
101
SHOWROOM
SHOWROOM
+/- 3,146
102
VALUE ZONE
V- 100
103
WOMEN
SERVICE
+/- 64
104
MEN
+/- 64
105
VESTIBULE
+/- 84
106
FILES / RECORDS
+/- 143
TOTAL: I I I +/- 3001 SQ. FT. I
• RETAIL BED COUNT - 40
— v
I
I
I
I
I
I
I
-
711
€ _....
I I
_... ... , .
TA 0-i
WALL 02
02
_
�...._
I
Q Q K Q
j
Q
3
Q
I
I
i
I
i
I
I
ki
� I
I l
I
l
I... ..... ....._..._ ..., ._ .._.. v E
SHOUJROOM
}
I
I
I
I
I
I
I
i
I
I
I
I
I
� I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
REVISIONS
BY
r �
' 4 00
ram. N C CO
o o
♦ N U
n
O C V
it Q E
E- C o
a� ti
3
�.. N
o ti
.__ E ti o
r
CV
M
I
11
0,0 m
0
I 0
t=9.
N
CIO
•r+ N
l a o
-T
J o 0
o �
C
to
R,
N
O
L
N
U
�F ,^
.a
a)M
O 0 J
Li
V� N mco
-�
m W C C)
0
L E L
•° I— E 0 s
Q 0 co 0
a
a�
N
Date: 02. 06. 14
Scale: AS NOTED
Project Mgr: LCH
Drawn: JDR
Job: 12-194
Sheet
A2
H:\Projects\Projects 2012\12194 - M.F. Zephyrhills, FL - Zephyrhills\04-CD\01-CD.A\04-Architechttal\A2-FDCTURE.dwg, 2/7/2014 8:39:55 AM, LCM
J(DIMEN / WOMEN
SCALE: 3/6" = 1'-O" RM 0103, 104
I MEN / WOMEN
SCALE: 3/5" = I'-0"
IG)lMEN / Uk:)MEN
SCALE: 3/6" = 1'-0"
O VESTIBULE
SCALE: 3/8" = 1'-0"
EDGE OF WALL
E
E
DISPENSER
LOCATION
TOILET TISSUE DISPENSER
-EDGE OF WALL
I I
I I
I I
I
SOAP DISPENSER
HIGHEST OPERABLE
PART OF ACCESSORY
U
4
4
-FINISH
FLOOR
PAPER TOWEL DISPENSER
NOTE:
I. TYPICAL MOUNTING HEIGHTS UNLESS OTHERWISE NOTED
O TYP I CAL MOUNTING HEIGHTS
RM 0103, 104 SCALE: 1/2" = I'-0"
IG)l VALUE zONE SECTION
RM 4`103, 104 SCALE: 1/4" = 1'-0"
P-5
P-12
P-12 I--1 I P-5
- - - - - - - - - - - - -
-----------WALL- 04------- ---:1
P-12
P-5
P-2
F------1 r------1
!WALL 02! !WALL 02
I I 2tD I I
I I I I
I I I I
I I I I
I I O I I
I I
I I
1 1
EQUAL EQUAL
DSHOWROOM SOUTH INTERIOR ELEVATION
SCALE: 1/4" = 1'-O" RM *101
DSHOWROOM EAST INTERIOR ELEVATION
SCALE: 1/4" - 1'-0"
P-12
P-5
F------1 F------1
I i I TA 01 TA 01 TA 01 TA 01 I
(WALL 02i !WALL 021
WALL 0211
I I I I I I
I
I I I I I I
I I I I I I I I I I
I I I I I I
i I I I I I I
I I I I I I I I I I I I I I I I I I I I I
I I I I I I I I I I I I I I
P-12
12'-4" 9'-I1" 1'-9" 1'-0" 1'-v
OSHOWROOM NORTH INTERIOR ELEVATION
SCALE: 114" = I'-O"
P-2 1 1 P-12
1 P-2
P-2
VZ 01 VZ 02 1 ---- ;I;
!WALL 021 / !WALL 021 /
I II II II II II II II II II II II I 1 I I I
I II II II II II II II it II II II I ! ! /19 i i /O
I II II II II II II II II II II I I
I II II II II II II I II II II I � �
I I I I I I (-----------1 (---- --� —� (-----------� (---- ------
I I I I I I I I I I I I I IL
I I I I I I I I I � I ! ! ��i i = ! I! !
LJ LJ LJ LJ LJ J L LJ I—J I—J LJ LJ
----- ------ h- -----i h- =-------- -----------
B
I A3 1 1 2 1 2 (.:/
EQUAL EQUAL EQUAL EQUAL
M105 O SHOWR1-BOOM WEST INTERIOR ELEVATION11
RIM
KEYED NOTES
OBASEBOARD - SEE FINISH SCHEDULE
OMATTRESS - TENANT SUPPLIED
JEXISTING STOREFRONT DOOR SYSTEM
OVALUE ZONE PLATFORM - SEE DETAIL C/AI
OTRIMBOARD - SEE DETAIL A/Al.
OEXISTING STOREFRONT WINDOW SYSTEM
OEXISTING WALL MOUNTED CHANNEL FRAMED MIRROR
OEXISTING DOOR SYSTEM
OEXISTING ELECTRIC HI-LO DRINKING FOUNTAINS.
10 EXISTING H.C. WATER CLOSET.
II EXISTING N.C. ACCESSIBLE LAVATORY.
12 EXISTING GRAB BARS.
13 WALL MOUNTED SOAP DISPENSER.
14 SURFACE MOUNTED PAPER TOWEL DISPENSER.
15 SURFACE MOUNTED TOILET TISSUE DISPENSER.
Iron EXISTING PIPE INSULATION KIT. G.G. TO PROVIDE IF NOT PRESENT.
11 EXISTING H.C. SIGN.
IS EXISTING FRP-I VENEER OVER EXISTING GWB (FIELD VERIFY)
PROVIDE IF NOT PRESENT,
19 EXISTING STOREFRONT DOOR SYSTEM TO REMAIN CLOSED AND
LOCKED.
20 WOOD CASED OPENING - SEE DETAIL 5/A1.
21 OPEN BEYOND.
RM 0101 TOILET ACCESSORIES
ACCESSORY SPECIFICATION
SEMI -RECESSED TOILET BOBRICK 8-661
TISSUE DISPENSER
SURFACE MOUNTED TOILET 50BRICK 8-(o85
TISSUE DISPENSER
SEMI -RECESSED PAPER BOBRICK 5-35c3
TOWEL DISPENSER
SURFACE MOUNTED PAPER BOBRICK 5-262
TOWEL DISPENSER
36" GRAB BAR BOBRIC-K 8-6806 X 36 SATIN
RM •101
FINISH WITH SNAP FLANGE
42 GRAB BAR
BOBRICK 8-6506 X 42 SATIN
FINISH WITH SNAP FLANGE
WALL MOUNTED SOAP
50BRICK 5-155
DISPENSER
COUNTER MOUNTED SOAP
BOBRICK 8-8221
DISPENSER
WALL MOUNTED MIRROR
BOBRICK 15-165 1830
SURFACE MOUNTED TOUCH
50BRICK 5-1811 #SOO
BUTTON HAND DRYER
RECESSED FEMININE NAPKIN
BOBRICK 8-353
DISPENSER
SURFACE MOUNTED FEMININE
BOBRICK 8-270
NAPKIN DISPENSER
RECESSED DISPENSER
BOBRICK 8-3013
TOILET -SEAT -COVER
BOBRICK 5-355
DISPENSER
GENERAL NOTES
1. �5EE SHEET IDI FOR ALL FINISH SCHEDULES AND MATERIALS.
2. CONTRACTOR TO COORDINATE AND VERIFY THE FINAL LOCATION
FOR ALL GRAPHICS WITH TENANT.
3. SEE SHEET A2 FOR GRAPHICS PLAN AND SCHEDULE.
4. FOR TYPICAL TOILET ACCESSORIES MOUNTING HEIGHTS, SEE "A"
THIS SHEET.
5. SOME KEYED NOTED AND ACCESSORIES DO NOT APPLY UNLESS
REFERENCED IN THIS PROJECT.
REVISIONS
BY
co
�.. Y T
coo
c°
o fl o
U
N -- a
U
•
o c `
�-� p U N d
3
--. N
u U)
p C
O
CD
G N
C`7
xl
5+�
U, W
0
m
LLJ
0
N
O
o �
y �
� U
O
L
N
C
U
L. � r-
O
0 LO
toLL d N M
O o J
m L�
-o
to
m W C: _
o C.)
.�
E
O I-- E 0
-'
O 00
(1)U N N
1`
a
a�
N
Date: 02. 06. 14
Scale: AS NOTED
Project Mgr: LCH
Drawn: JDR
Job: 12-194
Sheet
A3
H:TrojectsTrojects 2012\12194 - M.F. Zephyrhills, FL-Zephyrhills\04-CD\01-CD.A\04-Architectural\A3-IELEV.dwg, 2/7/2014 8:39:48 AM, LCM
INI I I I
FINISH MATERIAL LEGEND
FLOOR BASE TILE
PANT
FBT-I MANUFACTURER:
P-1 MANUFACTURER:
ICI DULUX PAINT
BUBMIEX:
STOREFLOORS
COLOR:
0119 PILLAR (WHITE)
COLOR:
BEIGE
FINISH:
EGGSHELL
SIZE:
6" x 12"'x 3/8"
LOCATION:
HEADBOARD MOLDING (MILLWORK
ITEM)
GROUT:
G-1
CEILING TILE 4 GRID (SITE SPECIFIC)
CONTACT:
KIMBERLY PENDERGRAPH
EXPOSED CEILING (SITE SPECIFIC)
618-638-1619
LOCATION:
IGROLIT
RESTROOM FLOOR ALONG PERIMETER
P-2 MANUFACTURER:
ICI DULUX PAINT
WALLS (TYPICAL)
COLOR:
#644 WINTER WHEAT (YELLOW)
TENANT FURNISH CONTRACTOR INSTALL
FINISH:
SATIN
LOCATION:
ACCENT WALL (REAR)
G-I MANUFACTURER:
LATICRETE OR EQUAL
P-3 MANUFACTURER:
N07 USED
BUBMIEX:
SANDED GROUT
P-4 MANUFACTURER:
NOT USED
NOTES:
I. INSTALL ONLY FULL UN -CUT TILES IN ALL CORNERS IN BOTH DIRECTIONS.
2. INSTALL ONLY FULL UN -CUT TILES WITHIN 3 COURSES (&'-0") OF CORNERS. NO
OTHER FIELD TILE TO BE LESS THAN 12" IN LENGTH).
3. PORCELAIN PLANK TILE IS FABRICATED IN A RECTIFIED FORMAT (ALL TILES ARE
EXACTLY IDENTICAL).
4. GROUT JOINTS TO BE 1/16" MAXIMUM, HOWEVER, A SOFT BUTT JOINT IS ALLOWABLE
BUT MUST STILL BE GROUTED USING NORMAL GROUTING PROCEDURES.
5. SEE MATERIAL LIST FOR TILE AND GROUT SPECIFICATIONS.
3/5" x 6" x 24''
PORCELAIN
2'-0"
COLOR: 11 MARBLE BEIGE P-5 MANUFACTURER: ICI DULUX PAINT PLANK (TYP.)
CONTRACTOR FURNISH AND INSTALL COLOR: *2003 CIELO BLANCO (OFF-WHITE)
FINISH: SATIN
G-2 MANUFACTURER: CUSTOM BUILDING PRODUCTS LOCATION: OVERALL WALLS, SOFFIT UNDERSIDE
BUBMIEX: POLY -BLEND NON -SANDED RESTROOM CEILING (IF GWB),
COLOR: 050 NUT MEG RESTROOM WALLS ABOVE 51", �0
CONTRACTOR FUW15H AND INSTALL STOCKROOM, CLEARANCE WALLS CARPET
GRAPNICS P-6 MANUFACTURER: ICI DULUX PAINT CARPET
COLOR:
'1250 RESTLESS SEA
TRANSITION 4 1/5"
LEVELER -SEE
TRANSITION DETAIL
GRAPHIC INSTALLATION COORDINATED THROUGH MATTRESS FIRM
SAM BUTERA (113b512051)
FINISH:
SATIN
PANTCONTRACTOR INSTALL
� O TM WATW4 QZT0R �&W ,CE DE%
LOCATION:
P-1 MANUFACTURER:
CENTER TOWER SOFFIT (MILLWORK ITEM
ICI DULUX PAINT
MATTRESS FIRM
COLOR.
1598 GREAT DESERT (TAN)
H CONTRACTOR INSTALL
FINISH:
SATIN
AD DISPLAY BOARD
LOCATION:
BASEBOARDS
I DISPLAY BOARD - PROVIDE BLOCKING IN WALL AS REQIRED.
P-8 MANUFACTURER:
ICI DULUX PAINT
C
O
p Qom' pQ
TILE 1— /l TT 1�1 ` /� T CORNS W.S
SCALE: 3/8" =�V-0" Jai VV
COLOR:
+110 SKY ROCKET RED (BRIGHT RED)
MOUNT BOTTOM OF DISPLAY AT 54" AFF.
CONTACT: MATTRESS FIRM
FINISH:
SATIN
FLUSH (BOTH SIDES)
316" CERAMIC TILE
AS SPECIFIED
° a
TENANT FURNISH CONTRACTOR INSTALL
LOCATION:
CLEARANCE CENTER LOW WALLS AND
CONTRACTOR FURNISH AND INSTALL
SOFFIT
VINYL COMPOSITION TILE
P-9 MANUFACTURER:
NOT USED
vCT-I MANUFACTURER
P-10 MANUFACTURER:
ICI DULUX PAINT
SERIES:
ESSENTIALSMANNINGTON
ESSENTIALS
COLOR:
#325 AUTUMN BLUSH
COLOR
143 FLAX (TAUPE)
SIZE:
12" x 12"
FINISH:
SATIN
GAUGE:
I/811
LOCATION:
COMFORT TEST AREA SOFFIT FACE
CONTACT:
HJ WEBER / KATHY LAPINE
CONTRACTOR FURNISH AND INSTALL
4 REST SPA WALLS 4 FURR-DOWN
216351.1200
P-11 MANUFACTURER:
ICI DULUX PAINT
LOCATION:
COLOR:
'S1 STONINGTON BEIGE (M1" 30YY 44/114)
CONTRACTOR FURNISH AND INSTALL
FINISH:
SATIN
VCT-2 MANUFACTURER:
MANNINGTGN
SERIES:
ESSENTIALS
LOCATION:
SPECIALTY BEDDING - SLEEP Rx AREA
CONTRACTOR FURNISH AND INSTALL
COLOR:
0290 ATLANTIS (BLUE)
CARPET
TRANSITION 4 1/8"
LEVELER- SEE
TRANSITION DETAIL
CUT TILES (12" MIN.)
ALLOWED AFTER 3
COURSES FROM
CORNERS
METAL CERAMIC
TILE STRIP - GLUE
DOWN TO FLOOR
3/8" PORCELAIN
PLANK AS SPECIFIED
12 MANU
FACTURER- ICI DULUX PAINT
SIZE: 12" x 12" a ° /THINSET
GAUGE; 1/8"COLOR. PM5 465 BASE 1403-0500Y (3 COATS)CONTACT: HJ WEBER / KATHY LAPINE FINISH: SATIN THINSET ADHESIVE ADHESIVE
216351.1200 LOCATION: ACCENT WALL (RIGHT OF ENTRY) CONCRETE SLAB
LOCATION: CLEARANCE CENTER, STORAGE NOTES: I GALLON FMLA 16 FFR 20P0 MAG 01"I6 LFY PO
CONTRACTOR FURNISH AND INSTALL 1 THE PRIMER FOR SHEETROCK A BCn GRAY
CARPET
C-I MANUFACTURER:
J 4 J
P-13 MANUFACTURER:
PATTERN:
8" W x 15" L
COLOR:
COLOR:
GRAY
FINISH:
LOCATION:
SALES AREA
LOCATION:
CONTACT:
KIMBERLY PENDERGRAPH
NOTES:
618-638-1619
OU.NER SUPPLIED, CONTRACTOR INSTALLED
P-14 MANUFACTURER:
C-2 MANUFACTURER:
LEES
COLOR:
PATTERN:
GTO55 / MAST MODULAR
FINISH:
COLOR:
206 / MALIBU
LOCATION:
WIDTH:
24" x 24"
NOTES:
LOCATION:
TRAINING ROOM
P-15 MANUFACTURER:
CONTACT:
KIM PENDERGRAPH
COLOR:
616-638-1619
FINISH:
OLNER SUPPLIED, CONTRACTOR INSTALLED
LOCATION:
FLOOR TILE
NOTES:
FT -I MANUFACTURER:
STOREFLOORS
P-16 MANUFACTURER:
BUBMIEX:
MIRABELLA
COLOR
COLOR
BEIGE
FINISH:
SIZE:
12" x 12" x 3/8"
LOCATION:
GROUT:
G-1
NOTES:
CONTACT:
KIMBERLY PENDERGRAPH
618438-1619
LOCATION. CENTER SERVICE DESK
AREA, ENTRY
TOILET ROOM FLOOR
TENANT FURNISH CONTRACTOR INSTALL
PORCELAIN FLOORM
PF-1 MANUFACTURER:
STOREFLOORS
PRODUCT:
TEAKWOOD PORCELAIN
PLANK
COLOR
CHERRY
GROUT:
G2
CARPET TRANSITION:
CTC116CT8
(CERAMIC TOOL COMPANY)
CARPET LEVELER
1/6" LEVELER STRIP
(JOHN50NITE, ROPPE)
51ZE:
6" x 24" x 3/8"
INSTALLATION SYSTEM:
THIN SET
CONTACT:
KIMBERLY PENDERGRAPH
618-638-1619
LOCATION:
RACE TRACK 4 VALUE ZONE
TENANT FURNISH - CONTRACTOR INSTALL
R5-1 MANUFACTURER:
ROPPE
PRODUCT:
RUBBER WALL BASE
PRODUCT NO:
1/8" SBR RU55ER-4"
COLOR:
' 53 BLACK-BROLN
GAUGE:
1/8"
HE IGHT:
4"
CONTACT:
ROPPE
WO531.9521 (PHONE)
419.435.1056 (FAX)
LOCATION:
SHOWROOM AREA,
HALL,5TORAGE
CONTRACTOR FURNISH AND INSTALL
BASE 1030-12001 GALLON FORM1A
BLK OPII YOX OPO4 OXR OPI (I COAT)
ICI DULUX PAINT PORCELAIN PLANK
'A0843 IVORY COAST/40YY 64 / 165 O FLOOR TILE TO
SATIN SCALE: FULL SIZE
ICI DULUX PAINT
$AI811 5ISAL/30YY 41 / 165
SATIN
ICI DULUX PAINT
OA1486 TUMBLEWEED TRAIL/30YY 33 / 145
SATIN
GLIDDEN PAINT
1305-05 / 188-AI386 MEDITERRANEAN
SATIN
ALL WALLS AT TRAINING ROOM
ACOUSTICAL CEILING TILE
SERIES-
NON -DIRECTIONAL
EDGE:
SQUARE LAY -IN
GRID:
15/16"
ITEM NO:
l69 (5 YR. WARRANTY)
COLOR:
WHITE (WH)
FHLCITI:
MEDIUM
LOCATION:
SHOWROOM 4 ALL AREAS
(RE: RCP)
WALL C ARM (FRP)
FRP-I MANUFACTURER:
MARLITE
(WWWMARLITE.COM)
PATTERN:
PEBBLED
PRODUCT•:
P 100
COLOR:
WHITE
CONTACT:
MARLITE
800331.1221 (PHONE)
330343.1296 (FAX)
LOCATION:
RESTROOM WALLS
ADJACENT TO ALL
FIXTURES UP TO 4'-0" AFF.,
MOP SINK
PROVIDE WHITE PVC TRIM MOLDING "M350" AT INSIDE
CORNERS, "M360" AT
OUTSIDE COMERS, "M365" AT DIVISIONS, AND "1'1310" AT
EXPOSED EDGES.
PROVIDE '71961" OUTSIDE CORNER GUARD AT EXPOSED
VERTICAL CORNERS.
CTC RAMP,
CLEAR ANODIZED
FINISHED ALUMINUM
(3/5" H X 8'-0" L)
VINYL COMPOSITE
TILE FLOORING AS
SPECIFIED __\
3/8" FLOOR TILE /
PORCELAIN PLANK AS
SPECIFIED
FLUSH —t
° a
°
v SUBSTRATE
CONCRETE SLAB—/
° a
4 a
THINSET ADHE:SIVi=
OVCT TO PORCEL,41N PUNK / FLOOR TILE
SCALE: FULL SIZE
FLOOR TILE (CTC3BCTS)/
PORCELAIN PLANK
(CTC11(oCTS) TO CARPET
METAL TRANSITION STRIP
CARPET AS
SPECIFIED --\
° _ v
CONCRETE SLAB
3/8" FLOOR TILE /
PORCELAIN PLANK AS
SPECIFIED
,— FLUSH \
v �
a ° v
THINSET ADHESIVE
W
JW
+ f__ W
0 U0
NOTE:
I. TUCK CUT CARPET EDGE UNDER TRIM
2. CARPET TRIM CAN BE MODIFIED IN THE FIELD TO ACCOMMODATE MOST RADIUSES.
A RADIUS OF LESS THAN 6'-0" MAY REQUIRE A PLYWOOD TEMPLATE. CUT NOTCHES
IN BASE TO CREATE RADIUS
3. TRIM TO BE ANCHORED USING CONSTRUCTION ADHESIVE - 'LIQUID NAILS' OR EQUAL
4. IF INSTALLATION REQUIRES CARPET TRIM AND LEVELER TO BE TURNED AT ANGLE,
CUTS TO BE MITERED ACCORDINGLY.
5. TO PREVENT LEVELER FROM TELEGRAPHING THROUGH CARPET, FLOAT WHERE
LEVELER MEETS CONCRETE AND WHERE LEVELER STRIPS BUTT END TO END. USE
ARDEX FEATHER FINISH OR COMPARABLE PORTLAND CEMENT BASED FLOOR PATCH.
USE ARDEX P51 PRIMER TO INSURE ARDEX BOND TO LEVELER.
01AgrmqvgCET TO PORCELAIN PLANK / FLOOR TILE
SCALE: FULL SIZE
o� 5EVELED LEVEL CHANGE
SCALE: ro" = I'-0"
�I VERTICAL. LEVEL CHANGE
SCALE: 6" = 1'-0"
OFINISH FLOOR PLAN
SCALE: 3/16" = I'-0"
ROOM FINISH SCHEDULE
NO.
ROOM
BASE
FLOORS
WALLS
REMARKS
NO,
N
S
E
W
101
SHOWROOM
RB-1
SEE PLAN
SEEA3
SEEA3
SEEA3
SEEA3
101
102
VALUEZONE
N/A
PF-1
P-12
P-12
P-5
P-12
102
103
WOMEN
FBT-1
FT-1
FRP-1, P5
FRPL 1, P5
FRP-1, P5
FRP-1, P-5
1
103
104
MEN
FBT-1
FT-1
FRP-1, P5
FRP-1, P5
FRP-1, P5
FRP-1, P-5
1
104
105
1
VESTIBULE
R13-1
VCT-1
P-5
P 5
P-5
P-5
105
106
F[LES /RECORDS
RB-1
VGT-1
P-5
R5
P-5
P-5
106
EXISTING FRP-I TO 4'-0" AFF., P-5 ABOVE
GENERAL NOTES
1. ALL FLOOR AND GROUND SURFACES SHALL COMPLY WITH SECTION 302 OF THE 2010 STANDARDS FOR
ACCESSIBLE DESIGN
2. ALL CHANGES IN LEVEL SHALL COMPLY WITH SECTION 303 OF THE 2010 STANDARDS FOR ACCESSIBLE
DESIGN
3. FLOOR TRANSITIONS TO BE VERIFIED BY TENANT, CONTRACTOR TO COORDINATE PRIOR TO
CONSTRUCTION.
4. SEE INTERIOR ELEVATIONS SHEET A3 FOR WALL FINISHES
5. CONTRACTOR TO COORDINATE AND VERIFY ALL FINAL COLOR AND FINISHES WITH MATTRESS FIRM
PROJECT MANAGER PRIOR TO ORDERING.
REVISIONS
BY
0r
00
�' UU CO
Y CO N0
v D
7 x ti vi
o �
it d E >
Q Q 0 o
3 r- E
CV
/ �D
t` o
ti a
N
M
�i
Y
1�
A
O !77�,
11tCti
o a-"p
A Gam+-�,wCh
2,
cam..
ui
- N
o
N `r
o 0
4 Q
o *
�Q)
a)
a..0
O
i
N
t
C
4v
U
o 0)
LO
M
:3Li CL N M
O o J
3
N m Imo.
,0
m W C C3
Of O o t
L E L
.0 E 0 t
O Q O m
L
A
S
a
O
N
Date: 02. 06. 14
Scale: AS NOTED
Project Mgr: LCH
Drawn: JDR
Job: 12-194
Sheet
ID1
H:\Projects\Projects 2012\12194 - M.F. Zephyrhillg, FL - Zephyrhi11s\04-CD\0I-CD.A\04-Architectura1\ID1-FINISH.dwg, 2/7/2014 8:39:41 AK LCM
DIVISION 1 GENERAL NOTES
DIVISION 3 CONCRETE
DIVISION 10 SPECIALTIES
1.02 KEYING
A. KEYING SHALL BE PER THE OWNERS REQUIREMENTS. TAG KEYS AND PROVIDE TO OWNER AT SUBSTANTIAL
SECTION 03300 CAST -IN -PLACE CONCRETE
COMPLETION.
SECTION 01340 SHOP DRAWINGS, PRODUCT DATA AND SAMPLES
SECTION 10522 FIRE EXTINGUISHERS
PART I GENERAL
03 GUARANTEE
1.A.
PART 1 GENERAL
PROVIDE ONE-YEAR GUARANTEE FOR ALL HARDWARE. PERIOD OF GUARANTEE SHALL BEGIN FROM DATE OF
PART 1 GENERAL
1.01 GENERAL
OWINER'S ACCEPTANCE.
121 REQUIREMENTS INCLUDED
A. COMPLY WITH PROVISIONS OF THE FOLLOWING CODES, SPECIFICATIONS, AND STANDARDS, EXCEPT WHERE
1.01 SUBMITTALS
A. SUBMIT SHOP DRAWINGS, PRODUCT DATA AND SAMPLES REQUIRED BY CONTRACT DOCUMENTS, OR AS
MORE STRINGENT REQUIREMENTS ARE SHOWN OR SPECIFIED.
END OF SECTION 05110
A PRODUCT DATA: REQUIRED
NECESSARY WHERE NOT INDICATED, So ARCHITECT CAN REVIEW, SELECT, CHECK FOR CONFORMANCE,
L ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE."
B. SHOP DRAWINGS: NOT REQUIRED
ETC., AS REQUIRED.
2. CONCRETE REINFORCING STEEL INSTITUTE (CR5U, "MANUAL OF STANDARD PRACTICE."
C. SAMPLES: N07 REQUIRED
1.02 RELATED REQUIREMENTS
1.02 FORMS
DIVISION s FINISHES
PART 2 PRODUCTS
A. DESIGNATED IN THE CONSTRUCTION SCHEDULE, OR IN A SEPARATE COORDINATE SCHEDULE, THE DATES FOR
A. FORMS ARE TO BE OF PLYWOOD, METAL, METAL -FRAMED PLYWOOD FACED, OR OTHER ACCEPTABLE PANEL-
SECTION OWOO CERAMIC TILE
SUBMISSION AND THE DATES THAT REVIEWED SHOP DRAWINGS, PRODUCT DATA AND SAMPLES WILL BE NEEDED.
TYPE MATERIALS TO PROVIDE CONTINUOUS, STRAIGHT, SMOOTH, EXPOSED SURFACES. FURNISH IN LARGEST
2DI MANUFAGTURER5/PRODUCT5
A COORDINATE WITH LOCAL MUNICIPALITIES AND PROVIDE FIRE EXTINGUISHERS.
ALLOW SUFFICIENT TIME IN THE SCHEDULE FOR ARCHITECT REVIEW AND POSSIBLE RESUBMITTALS IF REQUIRED.
PRACTICAL SIZES TO MINIMIZE NUMBER OF JOINTS.
B. DESIGN, ERECT, SUPPORT, BRACE, AND MAINTAIN FORM WORK TO SUPPORT VERTICAL AND LATERAL, STATIC
B. FIRE EXTINGUISHERS: SEE DRAWINGS FOR SPECIFICATIONS.
103 SHOP DRAWINGS
AND DYNAMIC LOADS THAT MIGHT BE APPLIED UNTIL CONCRETE STRUCTURE CAN SUPPORT SUCH LOADS.
PART I GENERAL
A. DRAWINGS SHALL BE PRESENTED IN A CLEAR AND THOROUGH MANNER
MAINTAIN FORM WOW CONSTRUCTION TOLERANCE COMPLYING WITH ACI 341.
PART 3 EXECUTION
1. DETAILS SHALL BE IDENTIFIED BY REFERENCE TO SHEET AND DETAIL, SCHEDULE OR ROOM NUMBERS
SHOWN ON CONTRACT DRAWINGS.
C. CONSTRUCT FORMS TO SIZES, SHAPES, LINES, AND DIMENSIONS SHOWN TO OBTAIN ACCURATE ALIGNMENT,
1.01 GENERAL
A. CERAMIC AND TYPES ARE INDICATED ON THE DRAWINGS AND ARE FROM A SINGLE MANUFACTURER OTHER
3.01 SCHEDULES
2.
LOCATION, GRADES, LEVEL, AND PLUMB WORK IN FINISHED STRUCTURE. PROVIDE OPENINGS IN FORM WORK TO
MANUFACTURERS WILL NOT BE CONSIDERED.
A INSTALL AS REQUIRED.
SHEET SHALL BE LABELED WITH CORRECT JOB NAME, LOCATION, ARCHITECT'5 PROJECT NUMBER, AND
ACCOMMODATE WORK OF OTHER TRADES. DETERMINE SIZE AND LOCATION OF OPENINGS, REGE55E5, AND CHASES
B. DELIVER MATERIALS IN ORIGINAL CONTAINERS WITH SEALS UNBROKEN AND LABELS INTACT UNTIL TIME OF
RI
SUBCONTRACTOR'S COMPANY NAME, ADDRESS, PHONE NUMBER AND NAME OF RESPONSIBLE
FROM TRADES PROVIDING SUCH ITEMS. ACCURATELY PLACE AND SECURELY SUPPORT ITEMS BUILT INTO FORMS.
USES. ENGAGE EXPERIENCED INSTALLER WHO HAS SUCCESSFULLY COMPLETED TILE INSTALLATIONS
END OF SECTION 10522
REPRESENTATIVE DET 5, COMPANY.
3. DRAWINGS, DETAILS, ETC. SHALL CLEARLY ILLUSTRATE ALL COMPONENTS AND ADJACENT COMPONENTS
1.03 FORM COATINGS
SIMILAR IN MATERIAL, DESIGN, AND EXTENT TO THAT INDICATED FOR THE PROJECT.
OF THE WORK
A. PROVIDE COMMERCIAL FORMULATION FORM -AFFECT COMPOUNDS WITH A MAXIMUM OF 35I MG/L THAT
C. COMPLY WITH PARTS OF ANSI 108 SERIES OF FINE INSTALLATION STANDARDS INCLUDED UNDER "AMERICAN
WILL NOT BONA WITH, STAIN, OR ADVERSELY AFFECT CONCRETE SURFACES AND WILL NOT IMPAIR SUBSEQUENT
NO
NATIONAL STANDARD SPECIFICATIONS FOR THE INSTALLER OF CERAMIC TILE" THAT APPLY TO TYPE OF
SECTION 10800 TOILET ACCESSORIES
1.04 PRODUCT DATA
TREATMENTS OF CONCRETE SURFACES.
SETTING AND GROUT MATERIALS AND METHODS INDICATED. TILE MAY BE THIN -SET.
A. PREPARATION:
PART I GENERAL
1. CLEARLY MARK EACH COPY TO IDENTIFY PERTINENT PRODUCTS OR MODELS WHICH ARE SPECIFICALLY
1.04 GRANULAR BASE
ID2 MORTAR AND GROUT
COVERED BY THE SUBMITTAL. REFERENCE ALL NUM5ER5 TO CORRESPOND TO THOSE IN CONTRACT
A. BASE 15 TO BE EVENLY GRADED MIXTURE OF FINE AND COURSE AGGREGATES t0 PROVIDE, WHEN COMPACTED
A. MORTAR SHALL BE PORTLAND CEMENT ASTM C150, TYPE I. GROUT SHALL BE ACID RESISTANT UPCO
HYDROMENT, TYPE AS RECOMMENDED BY THE MANUFACTURER FOR THE SPECIFIC TYPE OF TILE AND
1.01 SUBMITTALS
A. PRODUCT DATA: NON -REQUIRED
DOCUMENTS.
2. SHOW PERFORMANCE CHARACTERISTICS AND CAPACITIES.
A SMOOTH AND EVEN SURFACE BELOW SLABS ON GRADE.
METHOD OF INSTALLATION. COLR FOR FLOOR TILE IS SPECIFIED ON THE DRAWINGS.
B. SHOP DRAWINGS: NON -REQUIRED
3. SHOW DIMENSIONS AND CLEARANCES REQUIRED.
105 VAPOR BARRIER
B. DO NOT GROUT TILE UNTIL TILE 15 FIRMLY SET. SOAK OR DAMPEN JOINTS OF THE TILE TO BE GROUTED WITH
C. SAMPLES: NON -REQUIRED
4. SHOW WIRING OR PIPING DIAGRAMS AND CONTROLS.
A. BARRIER TO BE 6 MIL, POLYETHYLENE, WITH WATER VAPOR TRAN5MI551ON RATE OF 0.50 GRAINS/SQUARE
PORTLAND CEMENT GROUT. SOAK OR DAMPEN OTHER JOINTS AS RECOMMENDED BY THE GROUT
MANUFRER FORCE GROUT INTO JOINT LINES COMPLETELY (OILING JOINTS WITH COMPACTED GROUT AND
M ACTTUU
PART 2 PRODUCTS
5. DELETE MODEL NUMBERS, DIAGRAMS, DETAILS, ETC., NOT APPLICABLE TO THE SUBMITTAL.
FOOT/HOUR WHEN TESTED IN ACCORDANCE WITH A5TM E 96, METHOD B. PROVIDE MANUFACTURER'S
COVERING MORTAR FINISH JOINTS OF SQUARE EDGED TILE FLUSH WITH SURFACE. STRIKE OFF TOOL JOINTS
B. MANUFACTURER'S STANDARD SCHEMATIC DRAWINGS AND DIAGRAMS:
1. MODIFY AND
RECOMMENDED MASTICS AND GUSSET TAPE.
OF CUSHION EDGED TILE 70 DEPTH OF CUSHION. FILL GAPS AND SKIPS, AND RETOOL.
201 MANUFACTAWINGS
DRAWINGS DIAGRAMS TO DELETE INFORMATION WHICH 15 NOT APPLICABLE TO THE WORK
B. FOLLOWING LEVELING AND TAMPING OF GRANULAR BASE FOR SLABS ON GRADE, PLACE VAPOR BARRIER
FOR SPECIFICATIONS
A. SEE DRAWINGS FOR SPECIFICATIONS
2. SUPPLEMENT STANDARD INFORMATION TC PROVIDE INFORMATION SPECIFICALLY APPLICABLE
SHEETING WITH LONGEST DIMENSION PARALLEL WITH DIRECTION OF POUR LAP JOINTS 6 INCHES AND SEAL
123 CLEANING
TO THE WORK
JOINTS.
A. UPON COMPLETION OF THE PLACEMENT AND GROUTING, CLEAN TILE SURFACE 50 THAT THEY ARE FREE OF
PART 3 EXECUTION
125 SAMPLES
PART 2 REINFORCING MATERIALS
FOREIGN MATTER REMOVE LATEX-PORTLAND CEMENT GROUT RESIDUE FROM TILE AS SOON AS POSSIBLE
3.01 SCHEDULES
A. OFFICE SAMPLES SHALL BE OF 51ZE INDICATED, OR OF SUFFICIENT SIZE AND QUANTITY TO CLEARLY
UNGLAZED TILE MAY BE CLEANED WITH ACID 5OLUTION5 ONLY WHEN PERMITTED BY TILE AND GROUT
MANUFACTURER'S PRINTED INSTRUCTIONS, BUT SOONER THAN 14 DAYS AFTER INSTALLATION. FLUSH SURFACE
A. COORDINATE WITH DRAWINGS.
ILLUSTRATE :
2.01 REINFORCING MATERIALS
WITH CLEAN WATER BEFORE AND AFTER CLEANING.
I. FUNCTIONAL CHARACTERISTICS OF THE PRODUCT, WITH INTEGRALLY RELATED PARTS AND ATTACHMENT
A. REINFORCING BARS SHALL COMPLY WITH ASTM A 615, GRADE 40, DEFORMED WELDED WIRE FABRIC SHALL
END OF SECTION 10800
DEVICES AND TECHNIQUES,
COMPLY WITH ASTM A 185, WELDED STEEL WIRE FABRIC.
2. FULL RANGE OF COLOR, TEXTURE AND PATTERN FOR ARCHITECT SELECTION AT NO ADDITIONAL COST.
B. SUPPORTS FOR REINFORCING, BOLSTERS, SHAIRS, SPACERS, AND OTHER DEVICES ARE TO COMPLY WITH
END OF SECTION OS300
SUBMIT ONLY SPECIFIED COLOR RANGE IF DIFFERENT FROM MANUFACTURER'S STANDARD RANGE.
B. ALL SAMPLES OF A PARTICULAR PRODUCT, ASSEMBLY, UNIT, ETC., SHALL BE SUBMITTED AT THE SAME
CRSI SPECIFICATIONS.
C. COMPLY WITH CR51 RECOMMENDED PRACTICE FOR "PLACING REINFORCING BARS," FOR DETAILS AND METHODS
`' Q �y ' I
DI 1�7IV1�1 11 EQVIIENT
TIME TO ALLOW PROPER REVIEW AND COMPARISON BETWEEN SAMPLES.
OF REINFORCEMENT PLACEMENT AND SUPPORTS. REINFORCEMENT 15 TO BE FREE OF RUST AND MILL SCALE
SECTION OW50 VINYL COMPOSITION TILE
1/
AND OTHER MATTER THAT WILL ADVERSELY AFFECT BOND WITH CONCRETE.
1.06 SUBMITTALS
D. INSTALL WELDED WIRE FABRIC IN AS LONG LENGTH$ AS PRACTICAL. LAP ADJOINING PIECES AT LEAST ONE FULL
PART I GENERAL
NONE SPECIFIED
A. PERMITS, LICENSES, AND CERTIFICATES: FOR THE OWNER'S RECORDS, SUBMIT COPIES OF PERMITS,
MESH AND LACE SPLICES WITH WIRE. OFFSET LAPS OF ADJOINING WIDTHS TO PREVENT CONTINUOUS LAPS
LICENSES, CERTIFICATIONS, INSPECTION REPORTS, RELEASES, JURISDICTIONAL SETTLEMENTS, NOTICES,
IN EITHER DIRECTION.
1.01 SUMMARY
RECEIPTS FOR FEE PAYMENTS, JUDGMENTS, AND SIMILAR DOCUMENTS, CORRESPONDENCE AND RECORDS
ESTABLISHED IN CONJUNCTION WITH COMPLIANCE WITH STANDARDS AND REGULATIONS BEARING UPON
2.02 CONCRETE
A. DIMEN51ON: 12" X 12" X 1/8".
B. PROVIDE TYPE AND STYLE AS SCHEDULED IN THE FIN15H MATERIAL SCHEDULE.
Q Q
DIVISION 1Z �� 1�7 IN �7
PERFORMANCE OF THE WORK.
A. PORTLAND CEMENT - ASTM C 150, TYPE I, AGGREGATE - ASTM C33 (3/4" MAX.). READY -MIX CONCRETE
G. ADHESIVES:
SHALL COMPLY WITH REQUIREMENTS OF ASTM C 94, AND AS SPECIFIED. COMPLY WITH ACI 304 "RECOMMENDED
I. PROVIDE WATERPROOF STABILIZED TYPE ADHESIVE AS RECOMMENDED BY THE MANUFACTURER OF THE
1.01 CONTRACTOR RESPONSIBILITIES
PRACTICE FOR MEASURING, MIXING, TRANSPORTING, AND PLACING CONCRETE" REQUIRED SLUMP RANGE
MATERIAL BEING INSTALLED.
NONE SPECIFIED
A. REVIEW SHOP DRAWINGS, PRODUCT DATA AND SAMPLES PRIOR TO SUBMISSION.
3" TO 5".
2. ASPHALT EMULSION AND OTHER NON -WATERPROOF ADHESIVES WILL NOT BE ACCEPTABLE.
B. DETERMINE AND VERIFY:
B. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO PERFORM THE FOLLOWING CONCRETE TESTS ON
D. CONCRETE SLAB PRIMER: IN NECESSARY, PROVIDE NON -STAINING TYPE AS REQUIRED AND AS
1. FIELD MEASUREMENTS.
SITE. ALL TESTS SHALL BE PERFORMED AFTER THE ADDITION of WATER TO THE MIX.
Y THE MANUFACTURER OF THE MATERIAL BEING INSTALLED.
RECOMMENDED B E RE E R LDIVISION
13 SPECIAL CONSTRUCTION
2. FIELD CONSTRUCTION CRITERIA.
1. CYLINDER STRENGTH TESTS - ASTM C39t ONE SET OF FOUR CYLINDERS FOR EACH 50 CUBIC YARDS OR
E. CONTRACTOR TO BE RESPONSIBLE TO GIVE NEW FLOORING AN INITIAL WAXING PRIOR TO SPACE BEING
3. CATALOG NUMBERS AND SIMILAR DATA
FRACTION THEREOF. TEST ONE CYLINDER AT 1 DAYS AND TWO AT 28 DAYS. HOLD THE FINAL CYLINDER
OCCUPIED.
4. CONFORMANCE WITH SPECIFICATIONS AND DRAWINGS.
IN RESERVE.
C. COORDINATE EACH SUBMITTAL WITH REQUIREMENTS OF THE WORK AND THE CONTRACT DOCUMENTS,
2. SLUMP TESTS - A5TM C143.
1.02 VINYL COVE BASE
NONE SPECIFIED
DO NOT SUBMIT NON CONFORMING PRODUCTS.
C. DEPOSIT CONCRETE IN FORMS IN HORIZONTAL LAYERS NOT DEEPER THAN 24 INCHES AND IN A MANNER TO
A DIMENSION: 41NCH.
D E
D NOTIFY THE ARCHITECT IN WRITING, AT THE TIME OF 5U5MI5510N, OF ANY DEVIATIONS IN THE SUBMITTALS FROM
AVOID INCLINE CONSTRUCTION JOINTS. CONSOLIDATE PLACED CONCRETE BY MECHANICAL VIBRATING EQUIPMENT
B. PROVIDE TYPE AND STYLE AS SCHEDULED IN THE FINISH MATERIAL SCHEDULE.
REQUIREMENTS OF THE CONTRACT DOCUMENTS, OR OF ANY DISCREPANCIES WITHIN THE CONTRACT DOCUMENTS.
SUPPLEMENTED BY HAND SPADING, RIDDING, OR TAMPING. USE EQUIPMENT AND PROCEDURES FOR
`' Q �y SYSTEMS
DIVISION 1�7IV1�! 1�CONVEYING
E. BEGIN NO FABRICATION OR WORK WHICH REQUIRES SUBMITTALS UNTIL RETURN OF SUBMITTALS WITH
CONSOLIDATION OF CONCRETE IN ACCORDANCE WITH ACT 309.
END OF SECTION 0g650
ARCHITECT'S CONFORMANCE REVIEW.
D. DEPOSIT AND CONSOLIDATE CONCRETE 5LA55 IN A CONTINUOUS OPERATION AND IN A MANNER SO THAT
F. SUBMITTALS NOT PROPERLY REVIEWED BY CONTRACTOR FOR CONFORMANCE WITH CONTRACT DOCUMENTS
CONCRETE IS THOROUGHLY WORKED AROUND REINFORCEMENT AND OTHER EMBEDDED ITEMS AND INTO
SHALL BE RETURNED WITHOUT ARCHITECT'S REVIEW OR ACCEPTANCE.
CORNERS. BRING SLAB SURFACES TO PROPER LEVEL WITH STRAIGHTEDGE AND STRIKE OFF. SLAB TO BE
SECTION 09680 CARPETING
NONE SPECIFIED
FREE OF HUMPS AND HOLLOWS. MAINTAIN REINFORCING IN PROPER POSITION. PULL WELDING WIRE FABRIC
1.08 SUBMISSION REQUIREMENTS
TO CENTER OF SLAB, FABRIC LOCATED AT BOTTOM OF CONCRETE SLABS WILL BE REJECTED.
PART 1 GENERAL
A. MAKE SUBMITTALS PROMPTLY IN ACCORDANCE WITH APPROVED SCHEDULE, AND IN SUCH SEQUENCE
E. APPLY TROWEL FINISH TO MONOLITHIC SLAB SURFACES WITH A POWER -DRIVEN TROWEL. CONSOLIDATE
DIVISION 1�71VI�1 1� MECHANICAL
AS TO CAUSE NO DELAY IN THE WORK OR IN THE WORK OF ANY OTHER CONTRACTOR
CONCRETE SURFACE BY FINAL NAND -TROWELING OPERATION, FREE OF TROWEL MARKS, UNIFORM IN
1.01 CARPETING
B. NUMBER OF SUBMITTALS REQUIRED:
TEXTURE AND APPEARANCE. GRIND SMOOTH SURFACE DEFECTS THAT WOULD TELEGRAPH THROUGH APPLIED
A. PROVIDE TYPE AND STYLE AS SCHEDULED IN THE FINISH MATERIAL SCHEDULE.
I. SHOP DRAWINGS: SUBMIT THE NUMBER OF OPAQUE REPRODUCTIONS WHICH THE CONTRACTOR REQUIRES,
FLOOR COVERING SYSTEM.
B. ADHESIVES.
PLUS THREE (3) COPIES WHICH WILL BE RETAINED BY THE ARCHITECT. MAXIMUM ACCEPTABLE
F. ALL CONCRETE SHALL BE CURVED IMMEDIATELY AFTER FINISHING OPERATIONS IN ACCORDANCE WITH ONE OF
I. PROVIDE WHITE LATEX CARPET ADHESIVE SUCH AS Wt. HENRY COMPANY NO 356, ROBERTS
SEE MECHANICAL
SIZE IS 24" x 36" FOR ANY ONE SHEET.
THE FOLLOWING METHODS
COMPANY NO. 41-0504, OR AN EQUAL APPROVED BY THE ARCHITECT AND RECOMMENDED
2. PRODUCT DATA: SUBMIT THE NUMBER OF COPIES WHICH THE CONTRACTOR REQUIRES, PLUS THREE (3)
I. APPLY A 30 PERCENT SOLIDS LIQUID MEMBRANE FORMING CHEMICAL CURING COMPOUND IN ACCORDANCE
FOR THE PURPOSE BY THE MANUFACTURER OF THE SELECTED CARPET.
WHICH BE TAINED BY ARCHITECT.
WITH ASTM
2 VE SUCH AS W.W. HENRY MPANY NO. 246, ERTS COMPANY
OVIDE BEAM (APPROVED
/�
DIVISION 16 ELECTRICAL
3. SAMPLES:LSUBMIITT THE NUMBERSE
STATED IN EACH SPECIFICATION SECTION. IF NO NUMBER 15 GIVEN,
2. PROVIDE CONTIINUOUS MOISTURE TO CONCRETE IN ACCORDANCE WITH ACI 301.
FOR PURPOSE
411--05 2, OR AN EQUAL BY HE ARCHITECT AND RECOMMENDED
VERIFY CORRECT NUMBER WITH ARCHITECT PRIOR TO SUBMITTAL. MINIMUM OF TWO (2) SAMPLES.
G. PROVIDE CORNER BARS AT ALL WALL FOOTINGS t0 MATCH HORIZONTAL BARS.
BY THE MANUFACTURER OF THE SELECTED CARPET.
4. PROVIDE SUBMITTALS A5 REQUIRED BY THE INDIVIDUAL SECTION, BUT NO LESS THAN THAT STATED ABOVE.
C. AT INTERSECTION OF CARPET AND FLOOR TILE, PROVIDE ROPPE COMPANY, INC. VINYL TILE CARPET JOINER
C. SUBMITTALS SHALL CONTAIN:
END OF SECTION 03300
�U OR EQUIVALENT.
SEE ELECTRICAL
I. THE DATE OF SUBMISSION AND THE DATES OF ANY PREVIOUS SUBMISSIONS.
D. PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND
2. THE PROJECT TITLE AND NUMBER
PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR, SUBJECT TO THE APPROVAL OF THE
3. CONTRACT IDENTIFICATION.
4. THE NAMES OF:
Q^*'�/
DIVISION 4 MASONRY
ARCHITECT.
E. ALLOW THE OWNER TO INSPECT AND SELECT FROM SCRAP CARPET REMAINING AFTER THE INSTALLATION.
�+ �+ /� Q
OF �7�C IF I CATIONS
a. CONTRACTOR
BUNDLE, WRAP IN BURLAP, AND DELIVER TO THE OWNER THE CARPET SCRAPS 50 SELECTED.
b. SUBCONTRACTOR
c. SUPPLIER.
NONE SPECIFIED
END OF SECTION OS680
d. MANUFACTURER.
5. IDENTIFICATION OF THE PRODUCT, WITH THE SPECIFICATION SECTION NUMBER
6. FIELD DIMENSIONS, CLEARLY IDENTIFIED AS SUCH,
1. RELATION TO ADJACENT OR CRITICAL FEATURES OF THE WORK OR MATERIALS.
Q
DIVISION 1� TALC/
SECTION m°jWC PAINTING
8. APPLICABLE STANDARDS SUCH AS, BUT NOT LIMITED TO ASTM OR FEDERAL SPECIFICATION NUMBERS.
9. IDENTIFICATION OF DEVIATIONS FROM CONTRACT DOCUMENTS.
PART 1 GENERAL
10. IDENTIFICATION OF OPTIONS AVAILABLE, BUT NOT INDICATED IN THE 5PECIFICATION6, SUCH AS
NONE SPECIFIED
COLOR, FINISH, TEXTURE, ETC. WITH COMPLETE SAMPLES OR L15TING INCLUDED IN THE SUBMITTAL FOR
1.01 GENERAL
A IT 15 THE'INTENT OF THIS SPECIFICATION TO PRODUCE A PREMIUM JOB, WHICH WILL PROVIDE THE MAXIMUM
ARCHITECT'S SELECTION.
11. INDICATION OF TERMS TO BE INCLUDED IN THE WORK AND SHOWN ON THE SHOP DRAWINGS SHALL BE
DURABILITY, WHICH CAN REASONABLY BE EXPECTED FROM A PAINTED SURFACE.
DIMEN51ONED AND COORDINATED FOR PROPER FIT AND TIMELY INCLUSION.
DIVISION � WOOD and PLASTICS ICS
B. "PAINT" INCLUDES COATING SYSTEMS MATERIALS, PRIMERS, EMULSIONS, ENAMELS, STAINS, SEALERS, AND
12. IDENTIFICATION OF REVISIONS ON SUBMITTALS.
FILLERS, AND OTHER APPLIED MATERIALS WHETHER USED AS PRIME, INTERMEDIATE, OR FINISH COAT.
13. AN 8" x 3" BLANK SPACE FOR CONTRACTOR AND ARCHITECT STAMPS.
G. SPECIFIED PRODUCTS BELOW ARE MANUFACTURED BY SHERWIN WILLIAMS, EXCEPT WHERE OTHER
14. CONTRACTOR'S STAMPS, INITIALED OR SIGN, CERTIFYING THE REVIEW OF SUBMITTAL, VERIFICATION OF
MANUFACTURERS ARE INDICATED, AND ESTABLISH A STANDARD OF QUALITY. EQUIVALENT PRODUCTS OF
PRODUCTS, FIELD MEASUREMENTS AND FIELD CONSTRUCTION CRITERIA, AND COORDINATION OF
NONE SPECIFIED
ARCHITECT,
OTHER ACCEPTABLE MANUFACTURERS MAY NOT BE USED UNLESS APPROVED BY ARCHITECT.
THE INFORMATION WITHIN THE SUBMITTAL WITH REQUIREMENTS OF THE WORK AND OF CONTRACT DOCUMENTS.
D. PROVIDE BEST GRADE AND QUALITY MATERIALS ANDDUNLEPRODUCTS MANUFACTURED BY WILLIAMS.
MATCH COLORS AS INDICATED ON THE DRAWINGS. USE PREMIXED PAINTS IN50FAR AS POSSIBLE. THIN ONLY
AS PERMITTED ANY MANUFACTURER'S LABEL INSTRUCTIONS, AND AVOID UNNECESSARY THINNING.
1.09 RESU5MI5510N REQUIREMENTS
A. MAKE ANY CORRECTIONS OR CHANGES IN THE SUBMITTALS REQUIRED BY THE ARCHITECT AND RESUBMIT
1 '
DIVISION 1 THERMAL MOISTURE
E. PROTECT FINISHED SURFACES, WORK OF OTHER TRADES, AND PROPERTY OF THE OWNER FROM DAMAGE AND
UNTIL ACCEPTED.
SAND
DEFACEMENT. COVER FLOORS AND FIXED EQUIPMENT WITH DROP CLOTHS.
B. SHOP DRAWINGS AND PRODUCT DATA:
PROTECT ION
F. PREPARE SURFACES ACCORDING TO PAINT MANUFACTURER'S INSTRUCTIONS. EXAMINE FACTORY FINISHED
I. REVISE INITIAL DRAWINGS OR DATA, AND RESUBMIT AS SPECIFIED FOR THE INITIAL SUBMITTAL.
AND PRIMED SURFACES TO BE PAINTED, AND VERIFY COMPATIBILITY OF EXISTING MATERIAL WITH PAINT TO
2. INDICATE ANY CHANGES WHICH HAVE BEEN MADE OTHER THAN TH05E REQUESTED BY THE ARCHITECT.
BE APPLIED. APPLY PAINT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS
C. SAMPLES: SUBMIT NEW SAMPLES AS REQUIRED FOR INITIAL SUBMITTAL.
NONE SPECIFIED
ONLY TO SURFACES WHICH ARE THOROUGHLY DRY, SMOOTH, EVEN, CLEAN, FREE OF DUST AND PROPERLY
PREPARED TO RECEIVE THE INTENDED FINISH.
1.10 DISTRIBUTION
101 PAINTING
A. DISTRIBUTE REPRODUCTION OF SHOP DRAWINGS ANp COPIES OF PRODUCT DATA WHICH CARRY THE
ARCHITECT'S STAMP OF CONFORMANCE T0:
p� WINDOWS
DIVISION S DOORS AND
A. ACCEPTABLE MATERIALS
I. JOB SITE FILE.
I. ALL PAINTING TO BE SCHEDULED IN THE FINISH SCHEDULE.
2. RECORD DOCUMENTS FILE,
1. EQUIVALENT PRODUCTS OF THE FOLLOWING ARE AL50 ACCEPTABLE:
3. SUBCONTRACTORS.
PRATT 4 LANBERTT
4. SUPPLIER OR FABRICATOR
N 08'110 FINISH HARDWARE
GLIDDEN
5. OWNER (TO BE DISTRIBUTED BY THE ARCHITECT).
FIPART
PORTER
ENERAL
BENJAMIN MOORE
1.11 ARCHITECT'S DUTIES
B. UNDERCOAT5 AND THINNERS
A. REVIEW SUBMITTALS WITH REASONABLE PROMPTNESS AND IN ACCORD WITH SCHEDULE. ALLOW A MINIMUM
IDI GENERAL
I. PROVIDE UNDERCOAT PAINT PRODUCED BY THE SAME MANUFACTURER
OF TEN (10) WORKING DAYS FOR REVIEW, UNLESS SPECIAL HANDLING IS ARRANGED IN ADVANCE.
A. OBTAIN EACH TYPE O- AS SPECIFIED IN THE DOOR/HARDWARE SCHEDULE HARDWARE FROM A SINGLE
OF FINISH COAT.
B. AFFIX STAMP AND INITIALS OR SIGNATURE, AND INDICATE REQUIREMENTS FOR RE5UBMITTAL OR
MANUFACTURER, ALTHOUGH SEVERAL MAY BE INDICATED AS OFFERING PRODUCTS COMPLYING WITH THE
2. USE ONLY THINNERS RECOMMENDED BY THE PAINT MANUFACTURER AND USE ONLY
CONFORMANCE OF SUBMITTAL. ACCEPTANCE 15 FOR GENERAL CONFORMANCE WITH DESIGN CONCEPT AND
REQUIREMENTS.
THE RECOMMENDED LIMITS.
GENERAL COMPLIANCE WITH THE CONTRACT DOCUMENTS. QUANTITIES AND DIMENSIONS OF MATERIALS
B. FURNISH ALL HARDWARE, IN THEIR ORIGINAL PACKAGING, COMPLETE WITH ACCE5ORIE5 OF PROPER SIZE AND
C. COLOR SCHEDULES
WILL NOT BE REVIEWED. ACCEPTANCE OF A SUBMITTAL DOES NOT WAIVE OR ALTER THE REQUIREMENTS
DESIGN REQUIRED FOR THE PURPOSE FOR WHICH THEY ARE TO BE USED AND WITH ALL SCREWS, SHIELDS, AND
1. PROVIDE PAINTING AS SCHEDULED IN THE FINISH MATERIALS SCHEDULE.
OF THE CONTRACT DOCUMENTS.
OTHER ANCHORAGE DEVICES NECESSARY FOR A COMPLETE INSTALLATION. HARDWARE SCHEDULE SHOWN
a. ON GYPSUM DRYWALL, USE:
C. RETURN SUBMITTALS TO CONTRACTOR FOR P15TR15UTION OR FOR RESUBMI5SION.
ON THE DRAWINGS.
1. FIRST COAT - PIGMENTED PRIMER/SEALER
C. INSTALL EACH HARDWARE ITEM IN COMPLIANCE WITH THE NATIONAL BUILDERS HARDWARE ASSOCIATION AND
2. SECOND COAT - ACRYLIC LATEX ENAMEL
END OF SECTION 01340
THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. WHEREVER GUTTING AND FITTING 15 REQUIRED TO
3. THIRD GOAT - ACRYLIC LATEX ENAMEL
INSTALL HARDWARE ONTO OR INTO SURFACES WHICH ARE LATER TO BE PAINTED OR FINISHED IN ANOTHER
b. ON FERROUS METAL, USE:
WAY, COORDINATED REMOVAL, STORAGE, AND REINSTALLATION OR APPLICATION OF SURFACE PROTECTIONS
I. FIRST COAT - RUST INHIBITIVE ALKYD METAL PRIMER
WITH FINISHING WORK.
2. SECOND COAT - SEMI -GLOSS ALKYD ENAMEL
DIVISION 2 SITE
D. SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT
SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. DRILL AND COUNTERSINK UNITS NOT
3. THIRD COAT - 5EMI-GLOSS ALKYD ENAMEL
ON WOOD USE:
c. DOORS,
FACTORY PREPARED FOR ANCHORAGE FASTENERS. SPACE FASTENERS AND ANCHORS IN ACCORDANCE WITH
I. FIRST COAT - STAIN (SEE FINISH SCHEDULE)
INDUSTRY STANDARDS. SET THRESHOLDS FOR EXTERIOR DOOR5 IN FULL BED OF BUTYL -RUBBER OF
2. SECOND COAT - STAIN (SEE FINISH SCHEDULE)
NONE SPECIFIED
POLYIOSBUTYLENE MASTIC SEALANT.
3. THIRD COAT - VANISH LOW SHEEN "RUBBED EFFECT"
E. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR To ENSURE PROPER OPERATION.
REPLACE UNITS THAT CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE
APPLICATION MADE. INSTRUCT OWNERS IN PROPER ADJUSTMENT AND MAINTENANCE OF HARDWARE DURING
END OF SECTION 09900
FINAL ADJUSTMENT.
REVISIONS
BY
Go
M N
L Cz.
''--' ° o
U
rn C G G
O C • 2
8 U N J
.o
"T,
00
3 ti
-- oxN .
-o C
0
~ )tea
• N
CID
f
F-
°r
f
u
,T �z�w���
1
om
' k
4 t-
c-.�
CQ
N
� O
b �
0 0
25
o �
C
U � U
U_
L
C
tv
U
o
ul
CL M
L� a (1 M
O o -:3
U) - vi
m W v
O
E L
0
•�- E o s
O 00
U � N
L
t
a
a)
N
Date: 02. 06. 14
Scale: AS NOTED
Project Mgr: LCH
Drawn: JDR
Job: 12-194
Sheet
N1
r�
H:\Projects\Projects 2012\12194 - M.F. Zephyrhills, FL- Zephyrhills\04-CD\01-CD.A\04-Architectural\N1- SPEC.dwg, 2/7/2014 8:39:32 AM, LCM
ft
M Le
ELECTRICAL SPECIFICATIONS
I. THE WORK SUBJECT TO THESE SPECIFICATIONS SHALL BE IN CONFORMANCE WITH THE LATEST
EDITION OF THE NATIONAL ELECTRICAL CODE. THE INSTALLATION SHALL ALSO COMPLY WITH ALL
APPLICABLE RULES AND REGULATIONS OF LOCAL AND STATE LAWS AND ORDINANCES.
2. ALL ELECTRICAL EQUIPMENT SHALL BE SPECIFICATION GRADE AND SHALL HAVE THE PROPER UL
LABEL.
3. POWER DISTRIBUTION HOUSE PANEL50ARD PROVIDE DEAD -FRONT,
SAFETY -TYPE POWER DISTRIBUTION PANELBOARDS AS INDICATED WITH SWITCHING AND
PROTECTIVE DEVICES IN QUANTITIES, RATINGS, TYPES, AND WITH ARRANGEMENT SHOWN. INCLUDE
ANTI -TURN, SOLDERLESS PRESSURE TYPE MAIN LUG CONNECTORS APPROVED FOR USE WITH
COPPER CONDUCTORS.
4. HOUSE PANELBOARD IS EXISTING AND IS EQUAL TO SQUARE D TYPE "NQOD". VOLTAGE SHALL BE
AS INDICATED. ACCEPTABLE MANUFACTURERS INCLUDE GENERAL ELECTRIC, SIEMENS AND
CUTLER -HAMMER
5. TENANT PANELBOARDS PROVIDE DEAD -FRONT SAFETY TYPE LIGHTING AND BRANCH CIRCUIT
PANELBOARDS AS INDICATED WITH SWITCHING AND PROTECTIVE DEVICES- IN QUANTITIES, RATINGS,
TYPES AND ARRANGEMENTS SHOWN. INCLUDE ANTI -TURN, SOLDERLESS PRESSURE TYPE LUG
CONNECTORS APPROVED FOR USE WITH COPPER CONDUCTORS.
6. TENANT PANELBOARDS SHALL BE SQUARE D TYPE =00s. PANEL50ARD BOXES SHALL BE FIVE
AND THREE -FOURTHS INCHES (5-3/4") DEEP. VOLTAGE SHALL BE AS INDICATED.
1. ALL PANEL50ARDS SHALL BE CONNECTED, DISTRIBUTED PHASE, WITH CIRCUIT NUMBERING AS
INDICATED ON THE DRAWINGS. PANELBOARDS SHALL
BE NUMBERED WITH ODD NUMBERS ON THE LEFT SIDE OF THE PANEL AND EVEN NUMBERS ON THE
RIGHT SIDE OF THE PANEL..
6. UNLESS OTHERWISE INDICATED, PROTECTIVE DEVICES SHALL BE MOUNTED WITH TOP OF CABINET
OR ENCLOSURE 6'-b" ABOVE FINISHED FLOOR, SHALL BE PROPERLY ALIGNED, AND SHALL BE
ADEQUATELY SUPPORTED INDEPENDENTLY OF THE CONNECTING RACEWAYS. ANY AND ALL STEEL
FRAMING, SHAPES, ETC., NECESSARY FOR THE SUPPORT OF THE EQUIPMENT SHALL BE FURNISHED
AND INSTALLED BY THE CONTRACTOR WHERE THE BUILDING STRUCTURE IS NOT SUITABLE FOR
MOUNTING THE EQUIPMENT DIRECTLY THEREON. UNLESS OTHERWISE INDICATED, ALL BRANCH
CIRCUIT PROTECTIVE DEVICE ENCLOSURES SHALL BE NEMA TYPE I, GENERAL PURPOSE TYPE.
CIRCUIT PROTECTIVE DEVICES INSTALLED OUTDOORS OR EXPOSED TO THE WEATHER SHALL
HAVE WEATHERPROOF ENCLOSURES, NEMA TYPE =3R= OR TYPE =4=.
S. ALL SAFETY SWITCHES SHALL BE GENERAL DUTY TYPE. SWITCH MECHANISM SHALL BE
QUICK -MAKE, QUICK -BREAK COVERS SHALL BE INTERLOCKED WITH
MECHANISM TO PREVENT OPENING UNLESS SWITCH IS IN THE "OFF" POSITION. ALL ENCLOSURES
SHALL BE PRIMED AND FINISHED TO RESIST RUSTING AND CORROSION. SWITCHES SHALL BE
SQUARE-D, SIEMENS, GENERAL ELECTRIC OR CUTLER -HAMMER
10. CIRCUIT BREAKERS FOR MOUNTING IN HOUSE PANELBOARD SHALL BE BOLT -ON TYPE, MOLDED
PLASTIC CASE, AIR CIRCUIT BREAKER TYPE. BREAKERS SHALL HAVE THERMAL MAGNETIC TRIP
UNITS AND MULTI -POLE BREAKERS SHALL HAVE A COMMON TRIP BAR SO THAT THE TRIPPING OF
ONE POLE WILL AUTOMATICALLY TRIP ALL POLES OF THE BREAKER BREAKERS SHALL BE TRIP
FREE AND TRIP INDICATING AND SHALL HAVE QUICK -MAKE, QUICK -BREAK CONTACTS.
II. UPON COMPLETION OF WORK CORRECT ALL PANELBOARD CIRCUIT DIRECTORY CARDS TO
REFLECT AS -BUILT CONDITIONS. PANELBOARD DIRECTORIES SHALL BE UPDATED WITH
TYPEWRITTEN ACCURATE AND CURRENT INFORMATION BY THE CONTRACTOR AT THE END OF
CONSTRUCTION. DIRECTORIES SHALL REFLECT RECORD CONDITIONS AND INCLUDE CIRCUIT
NUMBER, TYPE AND LOCATION OF LOAD. A SET OF AS -BUILT DRAWINGS SHALL ALSO BE
PREPARED AND TURNED OVER TO THE OWNER
12. UNLESS SPECIFICALLY NOTED ON DRAWINGS, RACEWAYS SHALL COMPLY WITH THE FOLLOWING
RACEWAYS EXPOSED TO THE WEATHER OR IN DAMP LOCATIONS
SHALL BE GALVANIZED RIGID STEEL WITH THREADED CONNECTIONS.
RACEWAYS SHALL BE SIZED FOR THE CONDUCTORS INSTALLED BUT A MINIMUM
1/2". FULL SIZE MC CABLE IS ACCEPTABLE IN DRY LOCATIONS. HOMER INS TO
PANELS SHALL BE IN CONDUIT.
13. RACEWAYS RUN BELOW GRADE SHALL BE RIGID STEEL CONDUIT WITH A REDUNDANT GROUND
PATH INCLUDED. RACEWAYS RUN EXPOSED ON BUILDING EXTERIOR SHALL BE RIGID STEEL
CONDUIT.
14. ALL METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS
AND AT ALL BOXES, CABINETS, FITTINGS, AND EQUIPMENT.
15. ALL RACEWAYS SHALL BE SECURELY SUPPORTED FROM THE BUILDING STRUCTURE.
16. ALL RACEWAYS SHALL BE PROVIDED WITH AN EQUIPMENT GROUND CONDUCTOR
11. ALL BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SUITABLE SCREW
FASTENED COVERS. OPEN KNOCK -OUTS OR HOLES IN BOXES SHALL BE PLUGGED WITH A
SUITABLE BLANKING DEVICE.
Ia. OUTLET BOXES FOR EXPOSED WALL MOUNTING AND OUTDOOR INSTALLATION SHALL BE CAST
METAL TYPE "FS" OR 'TV" BOXES WITH SUITABLE GALVANIZED SHEET STEEL COVERS, OR CAST
METAL WEATHERPROOF OR VAPOR TIGHT COVERS WHEN NOTED ON THE DRAWINGS.
19. UNLESS OTHERWISE INDICATED, ALL CONDUCTORS SHALL BE COPPER NO. 12 AM. MINIMUM OR SIZE
AS SHOWN ON DRAWINGS. CONDUCTORS SHALL HAVE TYPE "THHN/THWN' INSULATION.
20. SPLICES, TAPS AND ATTACHMENT FITTINGS AND LUGS SHALL BE ELECTRICALLY AND
MECHANICALLY SECURE AND SOLDERLESS FOR CONDUCTORS SIZES NO. 8 AUG AND LARGER
THERE SHALL BE PLENTY OF SLACK CABLE IN BOXES, OUTLETS AND CABINETS TO INSURE THAT
THERE IS NO BINDING AT T14E BUSHINGS. ALL LUGS SHALL BE OF THE CORRECT SIZE FOR THE
CONDUCTORS INSTALLED AND IN NO CASE SHALL STRANDS BE CUT FROM A CONDUCTOR IN
ORDER TO FIT THE CONDUCTOR INTO A LUG. TAPING OF JOINTS SHALL BE WITH VINYL PLASTIC
ELECTRICAL TAPE TO INSURE INSULATION STRENGTH EQUAL TO THAT OF THE CONDUCTORS JOINED.
21. THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS
REQUIRED BY THE NEC AND AS SPECIFIED HEREINAFTER
22. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS.
23. THE CONTRACTOR SHALL VERIFY ALL LOCATIONS WITH THE OWNER PRIOR TO INSTALLATION. THEY
SHALL NOT BE CHARSED FOR MINOR LOCATION CHANGES PRIOR TO INSTALLATIONS. LOCATIONS
ARE APPROXIMATE. (DO NOT SCALE DRAWINGS).
24, THESE DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL ELECTRICAL LAYOUTS FOR BIDDING
PURPOSES ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PREPARE DETAILED SHOP
DRAWINGS AND CONFIRM SPACE ALLOCATIONS.
25. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES
FOR ELECTRICAL CONDUIT ROUTING AND EQUIPMENT PLACEMENT. AVOID INTERFERENCE WITH
ARCHITECTURAL AND STRUCTURAL FEATURES SUCH AN BEAMS, FOOTINGS, WINDOWS, ETC. NOTIFY
ARCHITECT IMMEDIATELY OF ANY CONFLICTS.
26. THE ELECTRICAL CONTRACTOR, THE HVAC FOREMAN AND THE GENERAL CONTRACTOR PROJECT
MANAGER SHALL INSPECT AND REVIEW THE CONDITIONS, AND SHALL COORDINATE THEIR WORK
SO AS TO PROVIDE ADEQUATE SPACE ALLOWANCE ABOVE CEILING FOR ALL TRADES.
21. THE PLANS SHOW THE LOCATION OF ALL FIXTURES AND EQUIPMENT AND ARE INTENDED TO
DEPICT THE GENERAL INTENT OF THE WORK IN SCOPE, LAYOUT AND QUALITY OF WORKMANSHIP.
THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL EVERY AND ALL ACCESSORY INTENDED FOR
THE PURPOSE OF EXECUTION OF THE WORK, BUT SHALL BE UNDERSTOOD THAT SUCH DETAILS WILL
BE PART OF THIS WORK
26, THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE
AND FUNCTIONAL ELECTRICAL SYSTEM INCLUDING CONTROLS AND CONNECTIONS TO NEW
SERVICES, SUPPORTS, AND HARDWARE REQUIRED FOR THE SATISFACTORY OPERATION OF THE
SYSTEM, WHETHER SPECIFICALLY SHOWN OR NOT ON THE DRAWINGS.
N
N
SYMBOL LIST
SYMBOL
DESCRIPTION
MOUNTING
®
1'x4' FLOORESCENT FIXTURE
SEE FIXTURE
SCHEDULE
2'x4' FLOORESCENT FIXTURE
SEE FIXTURE
SCHEDULE
SHADED FIXTURES CONTAIN
SEE FIXTURE
BATTERY PACK
SCHEDULE
F0-1
FLUORESCENT STRIP FIXTURE
SEE FIXTURE
SCHEDULE
LIGHT FIXTURE, WALL BRACKET
SEE FIXTURE
LETTER INDICATES TYPE
SCHEDULE
®LIGHT
FIXTURE, CEILING TYPE
SEE FIXTURE
LETTER INDICATES TYPE
SCHEDULE
® B
EXIT FIXTURE, SHADING INDICATES
SEE FIXTURE
SINGLE OR DOUBLE FACE
SCHEDULE
4p
EXIT LIGHT WITH EMERGENCY
SEE FIXTURE
I�
LIGHTS
SCHEDULE
EMERGENCY BATTERY UNIT
SEE FIXTURE
SCHEDULE
S
SWITCH, SINGLE POLE -LETTER
46" AFF TO CL
INDICATES LIGHTS CONTROLLED
OR AS NOTED
SWITCH, THREE WAY
4a" AFF TO CIL
$
OR AS NOTED
DIGITAL SWITCH OR AS
+48" AFF OR AS
NOTED
NOTED
0
WALL -MOUNTED OCCUPANCY
+48" AFF OR AS
SENSOR
NOTED
®CEILING
MOUNTED OCCUPANCY
SURFACE MOUNT
SENSOR
TO CEILING
INSTALL CONCEALED
LR
LIGHTING RELAY
IN AN ACCESSIBLE
AREA ABOVE CEILING
INSTALL CONCEALED
Ea
POWER PACK
IN AN ACCESSIBLE
AREA ABOVE CEILING
®
PHOTOCELL
SURFACE MOUNT
TO CEILING
IG�
DUPLEX RECEPTACLE, 125V, 20A
15" AM TO CL
WITH ISOLATED GROUND
OR AS NOTED
DUPLEX RECEPTACLE, 125V, 15A
IS" AFF OR AS
NOTED
DUPLEX RECEPTACLE, 125V, 15A
44" AFF OR 6"
ABOVE COUNTER
GFI�
DUPLEX RECEPTACLE, 125V, 15A
18" AFF OR AS
GROUND FAULT
NOTED
GF I�
DUPLEX RECEPTACLE, 125V, 15A
44" AFF OR 6
ABOVE COUNTER
DUPLEX RECEPTACLE, 125V, 15A
INFLUSH FLOOR
QUADRAPLEX RECEPTACLE, 125V, 15A
16" AFF OR AS
NOTED
QUADRAPLEX RECEPTACLE, 125V, 15A
44" AFF OR 6"
ABOVE COUNTER
m
TELEPHONE/DATA OUTLET. SEE
18" AFF OR AS
PLANS FOR WIRING CONFIGURATION
NOTED
FH
TELEVISION OUTLET
16" AFF OR
AS NOTED
PANEL50ARD 1201206V
SEE PANEL
-
OR 120/240V
SCHEDULE
Sn
MOTOR STARTER SWITCH WITH
AS NOTED
OVERLOAD RELAYS AS REQUIRED
MOTOR
AS NOTED
LO 60 3
DISCONNECT SWITCH
TOP 60" AFF
40
SIZE/ FUSE/ M OF POLES
OR AS NOTED
CONDUIT CONCEALED IN CEILING
NUMBER OF WIRES
SPACE OR WALL
INDICATED AS FOLLOWS
�--
CONDUIT IN FLOOR SLAB, CEILING
TWO WIRES
�
SLAB OR UNDERGROUND
THREE WIRES
HOME RUN TO PANEL (HASH MARKS
FOUR WIRES
INDICATE NUMBER OF WIRES)
CONDUIT RUN EXPOSED
WIREMOLD
AS NOTED
®
Q
TEMPERATURE SENSOR
AS NOTED
MECHANICAL PLANS
Q
JUNCTION BOX
AS NOTED
m
FIRE ALARM MANUAL
46" AFF OR AS
PULL STATION
NOTED
FIRE ALARM CHIME/FLASHING
80" AFF OR
LIGHT COMBINATION SIGNAL
SEE NOTE BELOW
gH
FIRE ALARM FLASHING
80" AFF OR
LIGHT SIGNAL
I SEE NOTE BELOW
®
FIRE ALARM SMOKE DETECTOR
ON CEILING OR
AS NOTED
WALL MOUNTED
6" BELOW THE CEILING TO
SMOKE DETECTOR
THE TOP OF THE DETECTOR
®
RELAY
AS NOTED
FRCP
FIRE ALARM CONTROL PANEL
60" AFF TO TOP
i�
"FAA" - FIRE ALARM ANNUNCIATOR
OR AS NOTED
O O 3❑ Q O
1 REFER TO LIKE NUMBERED NOTES
ALL MOUNTING HEIGHTS SHOWN ARE TO THE CENTERLINE OF THE
DEVICE UNLESS NOTED OTHERWISE
NOTE - THE DEVICE SHALL BE PLACED 80 INCHES ABOVE THE HIGHEST
FLOOR LEVEL WITHIN THE SPACE OR 6 INCHES BELOW THE CEILING,
WHICHEVER IS LOWER
System No. C-AJ-1079
F Ratings - 3 and 4 Hr (See Item 3C)
T Ratings - 0, 1/4, 1/2 and 3/4 Hr (See Item 2)
L Rating At Ambient - Less Than 1 CFM/sq ft
L Rating At 400 F - Less Than 1 CFM/sq ft
A
A �J
Section A -A
1. Floor or Wall Assembly - Min 4-1/2 in. thick reinforced lightweight or normal weight (100-150 pcf) concrete. Floor may
also be constructed of any min 6 in. thick UL Classified hollow -core Precast Concrete Units*. Wall may also be constructed of
any UL Classified Concrete Blocks*. Max diam of opening is 28 in. Max diam of opening in floor constructed of hollow -core
precast concrete units is 7 in.
See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of
manufacturers.
2. Through Penetrants - One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the
firestop system. The annular space between the pipe, conduit or tubing and the periphery of the opening shall be min 0 in.
(point contact) to a max 4 in. Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The
following types and sizes of metallic pipes, conduits or tubing may be used:
A. Steel Pipe - Nom 24 in diam (or smaller) Schedule 5 (or heavier) steel pipe.
B. Iron Pipe - Nom 24 in. diam (or smaller) cast or ductile iron pipe.
C. Conduit - Nom 4 in. diam (or smaller) electrical metallic tubing or nom 6 in. diam (or smaller) steel conduit or nom 1 in.
diam (or smaller) flexible steel conduit.
D. Copper Tubing - Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing.
E. Copper Pipe - Nom 6 in. diam (or smaller) Regular or heavier copper pipe.
Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876
Reproduced courtesy of Underwriters Laboratories Inc.
STI Created or Revised: October 09, 2069 C ®` U
-AJ-1079
(800)992-1180 • (908)526-8000 - FAX (908)231-8415 - E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com PAGE 1 OF 2
System No. C-AJ-1259
F Rating - 3 Hr
T Rating - 0 Hr
I A
A
Section A -A
1. Floor or Wall Assembly - Min 4-1/2 in. thick reinforced lightweight or normal weight (100-150 pcf) concrete. Floor may
also be constructed of any min 6 in. thick UL Classified hollow -core Precast Concrete Units*. Wall may also be constructed of
any UL Classified Concrete Blocks*. Max diam of opening is 7 in.
See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of
manufacturers.
2. Through Penetrants -One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the
firestop system. The annular space between the pipe, conduit or tubing and the periphery of the opening shall be a min of 0 in.
(point contact) to a max of 3 in. Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The
following types and sizes of metallic pipes, conduit or tubing may be used:
A. Steel Pipe - Nom 6 in. diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe - Nom 6 in. diam (or smaller) cast or ductile iron pipe.
C. Conduit - Nom 4 in. diam (or smaller) steel electrical metallic tubing or steel conduit.
D. Copper Tube - Nom 4 in. diam (or smaller) Type L (or heavier) copper tube.
3. Forming Material - (Optional, Not Shown) - Mineral wool batt packing material or polyurethane backer rod friction fitted
into opening and recessed from floor or wall surfaces as required to accommodate required thickness of fill material.
4. Fill, Void or Cavity Material* - Sealant - Min 1/2 in. thickness of fill material applied within the annulus, flush with both
surfaces of floor or wall. At the point contact location between penetrating item and concrete, a min 114 in. thick bead of fill
material shall be applied at the concrete/penetrating item interface on both sides of floor or wall.
SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant
*Bearing the UL Classification Mark
Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876
Reproduced courtesy of Underwriters Laboratories, Inc.
STI Created or Revised: October 09, 2009 C ®� U S
(800)992-1180 - (908)526-8000 - FAX (908)231-8415 • E-Mail:techserv@stifirestop.com - Website:www.stifirestop.com AGE 11OF�1
A55REVIATION6
AFC
- AVAILABLE FAULT CURRENT
LW -
LIGHT WHITE
AFF
- ABOVE FINISHED FLOOR
HP -
HORSEPOWER, HEAT PUMP
AHU
- AIR HANDLING UNIT
HVAC -
HEATING, VENTILATING, AIR CONDITIONING
BFG
- BELOW FINISHED GRADE
JB -
JUNCTION BOX
C
- CONDUIT
LRA -
LOCKED ROTOR AMPERES
CW
- COOL WHITE
MCB -
MAIN CIRCUIT BREAKER
DACT
- DIGITAL ALARM COMMUNICATOR TRANSMITTER
MLO -
MAIN LUGS ONLY
DACP
- DOOR ALARM CONTROL PANEL
N -
NEUTRAL
DN
- DOWN
NL -
NIGHT LIGHT
EF
- EXHAUST FAN
OB -
OUTLET BOX
EG
- EQUIPMENT GROUND
PB -
PULL BOX, PUSHBUTTON
ENCL
- ENCLOSURE
RECEPT-
RECEPTACLE
EWC
- ELECTRIC WATER COOLER
RLC -
RELOCATE
EWH
- ELECTRIC WATER HEATER
WV -
REMOVE
ETR
- EXISTING TO REMAIN
RWD -
REWIRE
EX
- EXISTING
SF -
SUPPLY FAN
FRCP
- FIRE ALARM CONTROL PANEL
SPEC -
SPECIFICATIONS
FAA
- FIRE ALARM ANNUNCIATOR
TL -
TWISTLOCK
FCU
- FAN COIL UNIT
TTB -
TELEPHONE TERMINAL BOARD
FHP
- FRACTIONAL HORSE POWER
TVT5 -
TELEVISION TERMINAL BOARD
FLA
- FULL LOAD AMPERES
UNO -
UNLESS NOTED OTHERWISE
G
- GROUND
VERT -
VERTICAL
GFI
- GROUND FAULT INTERRUPTER
UP -
WEATHERPROOF
HID
- HIGH INTENSISTY DISCHARGE
WW -
WARM WHITE
HORIZ
- HORIZONTAL
XFMR -
TRANSFORMER
IG
- ISOLATED GROUND
Type of Metallic Penetrant
Max Diam of Metallic Penetrant in.
T Rating Hr
Steel or Iron Pipe, Conduit
24
0
Copper Pipe or Tube
6
0
Steel or Iron Pipe, Conduit or EMT
4
1/4
Steel or Iron Pipe, Conduit or EMT
2
1/2
Steel or Iron Pipe, Conduit or EMT
F 1
3/4
3. Firestop System -The firestop system shall consist of the following:
A. Packing Material - Min 4 pcf mineral wool batt insulation firmly packed into opening as a permanent form. Packing material
to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of
fill material. When floor is constructed of hollow -core precast concrete units, packing material is to be recessed from both
surfaces of floor to accommodate the required thickness of fill material.
The thickness of the packing material is dependent upon the type and diam of the through penetrant (Item 2) as tabulated
below:
Thought Penetrant
Max Throught-Penetrant Diam In.
Min Mineral Wool Insulation Thkns In.
Steel Pipe, Conduit Or Iron Pipe
6
1-1/2++
Steel Pipe, Conduit Or Iron Pipe
24
3
Copper Tube Or Copper Pipe
6
3
++When annular space exceeds 2 in., packing material thickness to be min 3 in.
B. Fill, Void or Cavity Material* - Caulk - Min 1/2 in. thickness of fill material applied within the annulus, flush with top
surface of floor or with both surfaces of wall. When floor is constructed of hollow -core precast concrete units, fill material is
to be installed symmetrically on both sides of floor, flush with floor surfaces. At the point contact location between
penetrating item and concrete, a min 3/8 in. thick bead of fill material shall be applied at the concrete penetrating item
interface on top surface of floor and both surfaces of wall or hollow -core precast concrete floor.
SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant
C. Steel Cover Plate - (Not Shown) - Min 0.014 in. (No. 28 gauge) galv steel cut to fit the contour of the through -penetrant
assembly around the perimeter of the
(Item 2) with a min 2 in. lap on the top surface of floor and both surfaces of wall asse y p
through -opening. Seams of steel cover plate shall overlap a min 1/2 in. Steel cover plate secured to top surface of floor and
both surfaces of wall assembly by means of 114 in, diam by 1-3/4 in. long steel concrete anchors in conjunction with 1/4 in.
by 1-1A in. diam steel fender washers spaced a max 6 in. OC.
The hourly F Rating of the firestop system is dependent upon the use of the steel cover plate. If the steel cover plate is
used , the F Rating of the firestop system is 4 hr. If the steel cover plate is omitted, the F Rating of the firestop system is 3
hr.
*Bearing the UL Classification Mark
TV Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876
Reproduced courtesy of Underwriters Laboratories Inc. u
STI Created or Revised: October 09, 20b9 C ®` U
-AJ-1079
(800)992-1180 - (908)526-8000 - FAX (908)231-8415 • E-Mail:techserv@stifirestop.com - Website:www.stifirestop.com PAGE 2OF 2
GENERAL PROJECT AND DEMOLITION NOTES
I. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING
CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK
THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN
MADE. LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED, OR FOR
DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN
EXAMINATION BEEN MADE, WILL NOT BE ALLOWED.
2. ALL EXISTING CIRCUITS TO REMAIN SHALL BE RECONNECTED WHETHER INDICATED OR
NOT ON PROJECT DOCUMENTS.
3. NEW AND EXISTING CIRCUIT DESIGNATIONS MAY NOT REPRESENT ACTUAL FIELD
CONDITIONS. FIELD VERIFY WHERE REQUIRED AND INDICATE ACTUAL CIRCUIT USED ON
THE AS -BUILT DRAWINGS.
4. COORDINATE WITH OTHER TRADES FOR ITEMS IN THEIR SCOPE OF WORK WHICH WOULD
REQUIRE ELECTRICAL WORK DISCONNECTION, RECONNECTION, ETC. AND ARE NOT
INDICATED ON THE ELECTRICAL PLANS.
5. WHERE EXISTING PARTITIONS OR WALLS ARE SHOWN TO BE REMOVED, CONTRACTOR
SHALL REMOVE DEVICES TO THE NEAREST SOURCE JUNCTION BOX AND SHALL MAINTAIN
SERVICE TO REMAINING DOWNSTREAM ELECTRICAL OUTLETS. COORDINATE THE
DEMOLITION OF THE EXISTING WALLS WITH ARCHITECTURAL DRAWINGS.
6. PROTECT EXISTING ELECTRICAL EQUIPMENT AND INSTALLATIONS NECESSARY TO
REMAIN. IF EXISTING EQUIPMENT IS DAMAGED OR DISTURBED IN THE COURSE OF THE
WORK, REMOVE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL
CAPACITY, QUALITY, AND FUNCTIONALITY.
-1, REMOVE ELECTRICAL EQUIPMENT AND INSTALLATIONS INDICATED TO BE DEMOLISHED
IN THEIR ENTIRETY. WHERE THE EXISTING EQUIPMENT INDICATED TO BE DEMOLISHED
CONTAINS BRANCH CIRCUITRY SERVING OUTLETS THAT ARE EXISTING TO REMAIN,
RELOCATE THE BRANCH CIRCUIT TO AN ALTERNATE PANEL AND INDICATE THE CHANGE
ON THE AS -BUILT DRAWINGS.
8. ABANDONED WORK CUT OR REMOVE RACEWAY SLEEVES AND WIRING INDICATED TO BE
ABANDONED IN PLACE BELOW THE SURFACE OF ADJACENT CONSTRUCTION. CAP
RACEWAYS AND PATCH SURFACE TO MATCH EXISTING FINISH.
9, COMPLETELY REMOVE ALL EXISTING FLOOR BOX BRANCH CIRCUITS BACK TO PANEL.
REMOVE FLOOR DATA WIRING COMPLETELY BACK TO SOURCE. REMOVE FLOOR BOX
COVERS AND FLANGES AND GRIND FLOOR BOX TO BELOW FINISHED SLAB TO PREPARE
FOR CONCRETE FINISH WORK COORDINATE WITH GENERAL CONTRACTOR,
10, THE CONTRACTOR SHALL INCLUDE WITHIN THE BID ALL REQUIRED OFF HOUR, OVERTIME,
AND NON -BUSINESS HOUR WORK AS REQUIRED TO PERT-ORM THE DEMOLITION WITHOUT
DISRUPTING THE BUILDING TENANTS NORMAL BUSINESS OPERATIONS.
II. REMOVE ALL DATA WIRING AND EQUIPMENT RACKS THAT WILL NOT BE RE -USED.
RELOCATE TELEPHONE DEMARC CONDUIT TO NEW LOCATION AS REQUIRED.
12. ALL DEMOLISHED EQUIPMENT AND WIRING SHALL BE REMOVED FROM SITE AND
PROPERLY DISPOSED OF OR TURNED OVER TO THE OWNER AT THE OWNER'S SOLE
OPTION.
Wall Opening Protective Materials
SPECIFIED TECHNOLOGIES INC R14288 SUITE 2 200 EVANS WAY SOMERVILLE, NJ 08616 USA
SpecSeal Putty Paris, for use with max 4-II/16 by 4-I1/16 in. flush device UL Listed metallic outlet boxes Installed with steel cover plates In i
and 2 h fire rated gypsum board wall assemblies framed with min 3-1/2 In. deep wood or steel studs and constructed of the materials and in
the manner specified in the individual U300, U400 or V400 Series Wall and Partition Designs In the Fire Resistance Directory. Installation to
comply with the National Electrical Code (NFPA 10). Min 3/16 in. thick moldable putty pads are to be installed to completely cover the
exterior surfaces of the outlet box (except for the side of the outlet box against the stud) and completely seal against the stud within the
stud cavity. An additional 3/16 in. thickness of putty to be formed around the connector securing the end of each electrical metallic tube or
conduit to the box. When used with metallic outlet boxes larger than 4 by 4 In., a ball of putty is to be installed to plug the open end of
each electrical metallic tube or conduit within the outlet box. When max 4 by 4 In. metallic outlet boxes are used, the ball of putty in the open
end of each electrical metallic tube or conduit within the outlet box is optional. 11kien moldable putty pad outlet box protective material is
used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on the opposite sides of the wall may be
less than 24 in. provided that the boxes are not installed back-to-back
SpecSeal Putty Pads for use with max 4 by 3-3/4 by 3 In. deep UL Listed Nonmetallic Outlet Boxes manufactured by Carlon Electrical
Products and made from polyvinyl chloride, max 4 by 3-3/4 by 3 in, deep UL Listed Nonmetallic Outlet Boxes manufactured by Allied Moulded
Products Inc. and made from fiber -reinforced thermosetting plastic or max 4-1/16 by 3-5/6 by 3-1/8 in. deep UL Listed Nonmetallic Outlet
Boxes manufactured by Thomas 4 Betts Corp. and made from fiber -reinforced thermosetting plastic. Boxes shall also bear a 2 h rating under
the "Outlet Boxes and Fittings Classified for Fire Resistance" category in the Fire Resistance Directory. Installation to comply with the
National Electrical Code (NFPA 10). Boxes installed with steel or plastic cover plates. Putty pads and boxes for use in 1 and 2 h fire rated
gypsum board/wood stud wall assemblies constructed of the materials and in the manner specified in the Individual U300 Series Wall and
Partition Designs in the Fire Resistance Directory. Outlet box secured to wood stud by means of two nailing tabs in conjunction with nails
supplied with the outlet box. Min 3/16 in. thick moldable putty pads are to be Installed to completely cover the exterior surfaces of the
outlet box (except for the side of the outlet box against the stud) including nailing tabs and completely seal against the stud within the
stud cavity. An additional 3/16 in. thickness of putty to be formed around the end of each nonmetallic sheathed cable at its connection to
the box and to extend a minimum of 1 in. from the box onto the nonmetallic sheathed cable within the stud cavity. When moldable putty pad
outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on
opposite sides of the wall may be less than 24 in, provided that the boxes are not installed back-to-back
FI���TIONDET,41LS�T��IC��SDETAILS�T�LIC��S
NOT TO SCALE
O 1 ELECTimICAL Si�CIFICATION5
SCALE: NOT TO SCALE
00
m N
o 0 o
N cd [� U
5 Z
N in cxd *U.
NCd
G p., 4-
CD• U
C)in c'-d
N t
ti 10
o
~ 00 3
r-
3ti 3
O x N
G
ti o
tia
cm
0
.
6
• "it fLd
ti
•
-- 0)
�`'
•
D,.:
U)
L0 1 i► �= rb Ch
o
`drat
••� .••� _c_ca
•,
ss
� ..�5
L
m
t
c
m
i
I)
-a
tf)
3
LI_
r
L-
M
O
O
75
J
.=1
(�
t^
N
O
m
LL
m
W
-
N
ti
0
L
.0
F-
E
OCO:)
s
Q
U
CO
N
m
C
L
N
t
a
m
N
Date: 02. 06. 14
Scale:
AS NOTED
Project
Mgr: MPS
Drawn:
MW
Job:
12-194
Sheet
El
w
0
0
0
�r-
i
0
N
i
w
a
LC�
N
0
N
N
LIGHTING ALLOWANCE CALCULATION
ASHRAE 90.1
ROOM NAME
AREA IN
SQUARE FEET
LPD ALLOWED
TOTAL
WATTAGE
ALLOWED
FIXTURE
TYPE
LAMP TYPE
FIXTURE
WATTAGE
NUMBER
OF
FIXTURES
ACTUAL
WATTAGE
SHOWROOM
3479
1.70
5914.3
A
3-32WATT T-8
91
49
4459
0
AE
3-32WATT T-8
91
8
728
0
D
2-32WATT T-8
58
3
174
VESTIBULE
77
1.70
130.9
A
3-32WATT T-8
91
0
0
AE
3-32WATT T-8
91
1
91
0
0
FILES/RECORDS
135
0.80
108
A
3-32WATT T-8
91
1
91
0
AE
3-32WATT T-8
91
1
91
0
0
TOILETS
110
0.50
55
A
3-32WATT T-8
91
0
0
AE
3- WATT T-8
91
2
182
0
0
TOTALS
3801
6208.2
5816
ALLOWANCES FOR DISPLAY LIGHTING (type D fixtures at Value Zone -174
COMPLIES BY 566.2
CONTROLNOTES
AUTOMATIC LIGHTING CONTROLS ARE FURNISHED VIA OCCUPANCY SENSORS AND TIME CLOCK CONTROLLED LIGHTING CONTROL PANEL
KEYED NOTES REV1510N5 bT
DRAWING NOTES O
1. EXISTING ELECTRICAL SERVICE t0 REMAIN.
21
2. NEW LIGHTSTAT LIGHTING CONTROL PANEL. REFER TO
j LIGHTING CONTROL DETAIL SHEET FOR MORE INFORMATION.
L-
3. NEW LIGHTSTAT HVAC CONTROL PANEL. REFER TO LIGHTING
EX X i CONTROL DETAIL SHEET FOR MORE INFORMATION.
EX EX --EX --- EX 4 -- - EX_
EX - -- - - - --, I_ _ - -- -- -- - �, EXISTING LIGHTING CIRCUIT HOME RUN TO BE CONTROLLED
S EX
11 - :. ;`! _. i G RING
CONTROLLING THE CIRCUIT VIA LIGHTING CONTROL NANDI ROUTE IANTERCEPT NEW LIGHTING
- --I -
2_-� _ _ - - _ EX� CONTROL PAN
-
__--
- _ I 12
EX • 1 EX - 1 X fi EX = -I - EX " I " €�<" • 1 - X . J EX • 1 5. PROVIDE CEILING OCCUPANCY SENSOR FOR CONTROL OF
• • - , LIGHTS IN THIS ROOM WITH LEVITON "OSC20M SENSOR
•
3l0 � AND OSC SERIES POWER PACK
EX c.
PROPVIDE WALL MOUNTED OCCUPANCY SENSOR SWITCH FOR
12 '-- I CONTROL OF LIGHTS WITH LEYITON DECORA STYLE MODEL
NL _.- NL _ NL __ i-- -
IS EX EX • 3 EX . 3 EX EX • 3 EX • 3 EX - 7, PROPOSED LOCATION FOR NEW RTU TEMPERATURE SENSORS. 00
DER THE DIAGRAM SHEET E3TAts AND INSTALL SENSORS m
co
P
-- --- _ 12 19 ,i G.
t c0
(" I ALLOWANCE
"C �L -- 1_ I� 101 - 28 I A OUTLETS DATA WITHIN THE SALES DESK ~ ¢ F .
I 1�'.. �./W 8 PROVIDE AND INSTALL TWO QUAD RECEPTACLES FOR POWER
SCALE: Not to SCALE I 1� ( ./. �!D TWO QUAD LE FOR w co ,� °
O 22k AN ATA VICES. LOCATE THE BOXES x N
f �' ', : I `� I -. _ I BOXES FOR POWER D D DE �
GFI -- - _- - - --N - � G Y
'- - __ _� � � AS HIGH AS POSSIBLE WITHIN THE MILLWORK VERIFY AND �
EX 1 EX' --a 1- _ _ •'....1 EX • 1 -- ... -_ X .._-1 -:EX • I EX- �__ 1 EX • 1 SIG j EXTEND CONDUIT STUB -UPS INTO SALES DESK CUT AND PATCH ,�/ N a
9� EX j FLOOR AS REQUIRED FOR INSTALLATION OF CONDUIT. S,
-- -
_ _.._ - .... r_ ....._.., ....... .,..._t.. _._.. p V N .F
_ �'
E I + : u RTU-2 - 131
22 �( 10 EX _ 9. EXISTING ROOF TOP MECHANICAL UNITS TO REMAIN AND BE tl 4 E "
L_ 22 `-rOEX a �� o
EX LI 1 4 ` WIRED TO EXISTING PANEL LI AS SHOWN. PROVIDE 120 ¢ 0
\ Ll-1�,1921 - - - VOLT WIRING FROM PANEL Ll CIRCUIT 023 TO POWER 3
Y
i i ;' -
- RECEPTACLES.
11 o .
' LI 12 � i � x
� 3
t2: �- �'
- EX • 3X 3 , EX 3 0 LI-18 I 10. EXISTING DUCT TYPE SMOKE DETECTOR INSTALLED IN •�
I EX 3 EX �i 3 EX ;3 EX • 3
AIR DUCTS OF ROOF TOP UNIT. ACTIVATION OF DUCT a
- - - -- I- ,EX DER LCICTzHRELAYLWINITIATE RED TO EXISTDOWN
I C� FIRE A�Af-d'1 SYSOF TOP TEM.
, IT m
--_ -!_1- - ! 11
- -- -- !
:
18. m ._. I I
EXISTING EXTERIOR LIGHTS WIRED TO THE HOUSE PANEL
x.- 18 I TO REMAIN AS IS.
18
NL 3 NL j
- X EX 12. EXISTING SHOW WINDOW RECEPTACLE MOUNTED IN CEILING
EX 5 EX X �' �''' NL EX • 5 I EX • 5 i SHALL BE WIRED TO THE CIRCUITS AS SHOWN. 1
8 I r x EX • 5 13. EXISTING EMERSENCY BATTERY BALLAST IN LIGHTS TO BE
- WIRED TO UNSWITCHED LIGHTING CIRCUIT WIRING. TYPICAL.
I '-4" 14. EXISTING ROOF TOP MAINTENANCE RECEPTACLES TO BE
12 WIRED t0 PANEL 'LI' CIRCUIT 023.
19
yj
16
X - a 9 EX 9 EX 9 Ek 9 EX 9 EX - 9
23 - -J • %J 15, PROVIDE FINAL CONNECTION t0 THE ELECTRIC WATER
9 EX ' •
EX X
SIGN LIi2 2� �E HEATER PROVIDE A DOUBLE POLE 30A SWITCH FOR A
- - -.... Ll LOCAL DISCONNECT. .
}_. ` __ 1 16. Hl EXHAUST FAN TO BE WIRED INTO ROOM LIGHTING w
EX 1-2i 23 GFI �X
CIRCUIT 50 THAT FAN RUNS WHENEVER LIGHTS ARE ON. x
Il 22-- 2 EX • 5 1r2TU-1 EX • 5 EX-- ♦ 5 EX • 5 I1 li. PROVIDE QUAD RECEPTACLE AT UTILITY PHONE BOARD AND
WIRE TO CIRCUIT As INDICATED.
- 10 4' I& NIGHT LIGHTS AND EXIT SIGNS SHALL BE WIRED DIRECTLY TO
FILES/ 2 N
3 s SWITCH RATED CIRCUIT BREAKER IN ELECTRICAL PANEL.
-- I NIGHT LIGHTS AND EXIT SIGNS ARE ILLUMINATED CONSTANTLY.
12 EX EX ! 18 I -- -
2
16 A 7F 4)E EL NL 22 I ! 19. JUNCTION BOX AND BRANCH CIRCUIT FOR STORE FRONT SIGN.
EX 25 EX g -1x~-- EX • 9 EX - EX INTERCEPT HOME RUN AND ROUTE VIA LIGHTING CONTROL
- 12 PANEL.
I; j
EX F- X V LUE T 20. INTERCEPT EXISTING MANUAL SWITCHES FOR BRANCH CIRCUIT
----------
5 25 E _ - -_ _. - _.._._-._i..-----.-,.-- '- III FOR SALES AREA LIGHTING AND ROUTE VIA NEW LIGHTING
13
li 10E 8 E Ll-9I LI-1 OF THE CONTROCONTROL PANEL PANEL. L CONTROLLE CIRCUITS ARE TO BE ON .
LOAD SIDE
EF-
EX I EX j 21. EXISTING TENANT. NO WORK IN THIS AREA.
- -- 25 10 25 E E EX • 5 -1 EX • 5 EX • - 24
6 16 - 22. PROVIDE NEW RECEPTACLES AND WIRE TO CIRCUIT
-�
r I�i
I 15 INDICATED.
- - 26
EX 16 VEST.
l - _ - - � 23. PROVIDE AND INSTALL WALKER 880CM1-1 SINGLE GANG
EF-1 - -
---- .. ._ „\UNI 1111
13 Im LI 31 _ --- --- - f- --- I FLOOR BOX WITH DUPLEX RECEPTACLES AND BRASS COVER "
EX 4
PLATE AND ALL REQUIRED FLOOR TRIMS, SAW CUT AN
LI-35 X- -- - PATCH FLOOR AS REQUIRED TO INSTALL CONDUITS. yj
LIGHT SLAT 3O SIGN ''�V LL•
M `
--f HVAC PANEL EX EX------19 EX `Q.:• c�
--....- -- -- --- 11 - --
lO EXISTING PANEL 'Ll' 11 11 LI-34 • M �M
4 _
LI-33 EXISTING PHONEBOARD
O LIGHT STAT '�', °wo
LIGHTING
CONTROL PANEL ,.. ``~` a U
° °°lr+enummnaa��a`� a ca _(a
NEE
101 r=LECTRicAL FLAT
SCALE:3/16" = I'-1
EX - WIREWAY
1.5"CWITH 4"I,
1 01 EG.
THE PARTIAL El
RISER Is EXISTI
PANEL
"HP"
O
O
SHOWN FOR REF
ONLY. THERE
200A
ASSOCIATED WI
120/206V
EX
EX
RISER DIAGRoP
3P/4W
100A
200A
METER
METER
EX
2B" C WITH 4 03/0,
1 03/0 EG,
200A
120/208V
3P/4W
DISC.
-SWITCH
EX
1200A
NEMA 3R
1-2V C WITH 4 03/0,
DI -SC.
3 PARALLEL
I EG.
SWITCH
4 0400 KCMII
PANEL
"L1"
200A
120/208V
EX
UTILI
3P/4W
sPD cor
TRAl
EX
120/2k
3 PH>r
SECONi
-------_----
3 PARALLEL 4" C WITH
4 0400 KCMIL, 1-02/0 EG EACH
03/0 GND TO BUILDING STEEL,
FOUNDATION STEEL, METALLIC
MAIN PER NEC 250-50 AND 2',
f' L %0-0X00*00DULE 3 EX RISER
SRN F CALE: NOT TO SCALE SHOWN RE REFENCE ONLY SCALE: NOT TO SCALE SHOWN FOR IREFERENCE ONLY
MANUFACTURER: SQUARE D
MLO OR MCB:
MLO
PANEL:
L1
TYPE: NEMA 1
FEED:
BOTTOM
VOLTAGE:
120/2013 PH, 4 WIRE
MOUNTING: SURFACE
CU ORAL WIRE:
CU
MAIN AMPS:
200 AMP
LOCATION: FILES/RECORD ROOM
AIC RATING:
42,000 AMPS
FEEDER:
200 AMP SPACES:
42
BREAKER OPTIONS:
NOTES:
SEE RISER DIAGRAM FOR WIRE & CONDUIT SIZES REQUIRED
CKT
CKT
NO.
LOAD
:OPT
CODE
KVA
WIRE
BRKR
PHASE
BRKR
WIRE
KVA
CODE
OPT:
LOAD
NO.
1
SHOWROOM LIGHTING
L
1.46
12
20
A
20
12
1.08
R
; SHOWROOM RECEPTACLES
2
3
SHOWROOM LIGHTING
L
1.00
12
20
B
20
12
0.90
R
SHOWROOM RECEPTACLES
4
5
SHOWROOM LIGHTING
L
1.18
12
20
C
20
12
0.72
R
; SHOWROOM RECEPTACLES
6
7
EMERG. LIGHTS & EXIS SIGNS
L
0.73
12
20
A
20
12
0.90
R
; SHOWROOM RECEPTACLES
8
9
SHOWROOM LIGHTING
L
0.81
12
20
B
20
12
0.72
R
COMM. BOARD RECEPTACLES
10
11
1
E
7.20
3
3P
100 1
C
20
12
0.36
R
; COLUMN RECEPTACLES
12
13
E
7.20
3
A
20
1
:SPARE
14
15
E
7.20
3
B
20
12
0.18
R
; SHOW WINDOW RECEPTACLE
16
17
RTU-2
E
7.40
3
3P
100
C
20
12
1.10
L
: SIGN
18
19
E
7.40
3
A
20
12
0.18
R
SHOW WINDOW RECEPTACLE
20
21
E
7.40
3
B
20
12
0.18
R
SHOW WINDOW RECEPTACLE
22
23
MAINT. RECEPTACLE
R
0.36
12
20
C
20
12
0.18
R
SHOW WINDOW RECEPTACLE
24
25
FILES/RECORD RM LIGHTING
L
0.46
12
20
A
20
12
0.18
R
SHOW WINDOW RECEPTACLE
26
27
FLOOR RECEPTACLES
R
0.36
12
20
B
20
12
0.18
R
: SHOW WINDOW RECEPTACLE
28
29
SPARE
1
20
C
20
12
0.18
R
SHOW WINDOW RECEPTACLE
30
31
SHOWROOM RECEPTACLES
R
0.72
12
20
A
20
12
0.18
R
; SHOW WINDOW RECEPTACLE
32
33
LIGHTSTAT LIGHTING C.P.
E
0.30
12
20
B
20
12
1.20
L
SIGN
34
35
LIGHTSTAT HVAC C.P.
E
0.30
12
20
C
20
12
0.18
R
SHOW WINDOW RECEPTACLE
36
37
SPARE
1
20
A
20
12
0.18
R
SHOW WINDOW RECEPTACLE
38
39
ELECTRIC
WATER HEATER
E
2.25
10
2P
30
B
20
12
0.18
R
SHOW WINDOW RECEPTACLE
40
41
E
2.25
10
C
20
12
1.20
L
SIGN
42
KVA PER PHASE=
BUS A:
20.66
DEMAND
BUS B:
22.86
KVA
FACTOR
DEMAND KVA
BUS C:
22.61
(L) LIGHTING:
9.14
X
1.25 =
11.42
TOTAL KVA:
66.14
(R) RECEPTACLES:
8.10
X
1.00 =
8.10
(R) RECEPTACLES:
0.00
X
0.50 =
0.00
PANEL CALCULATIONS
(H) HVAC:
0.00
X
1.00 =
0.00
DEMAND KVA:
68.42
(E) EQUIPMENT:
48.90
X
1.00 =
48.90
TIMES 1000
JOB NAME:
(K) KITCHEN EQUIPMENT:
0.00
X
0.65 =
0.00
DIVIDED BY 1.732
M.F. ZEPHYRHILLS, FL
(S) SUBFEED:
0.00
X
1.00 =
0.00
DIVIDED BY 208
MPS #:
LARGEST MOTOR:
0.00
X
0.25 =
0.00
214009
TOTAL DEMAND KVA:
68.42
PANEL DEMAND AMPS:
189.93
DATE LAST MODIFIED
2/5/2014