Loading...
HomeMy WebLinkAbout7890 Hwy 301ANEW STORE LOCATION FOR MR. RANDY HALER & MR. JOSHUA LINCOLN M• J 1 ZEPHYR COMMANS SHOPPING CENTER 7890 HWY. 301 ARCHITECT: SAMUEL OLMEDO, ARCHITECT P.O.BOX 784825 WINTER GARDEN, FLORIDA 34787 PHONE (407) 967- 3109 EMAIL: soarcht@ yahoo.com , t d aa. e �y �. ., I ur' s n �a ,,mil ; !R t e 0u A d€� s: z- m` NORTH VICINITY MAP PROJECT SITE LOCATION PROJECT TENANT LOCATION ZEPHYRHILLS., FLORIDA 34551 CODE DATA APPLICABLE CODE 1. 2010 FLORIDA BUILDING CODE: BUILDING 2.2010 FLORIDA BUILDING CODE: EXISTING 3. 2010 FLORIDA BUILDING CODE: PLUMBING 4. 2010 FLORIDA BUILDING CODE: FUEL GAS 5.2010 FLORIDA BUILDING CODE: MECHANICAL 6. 2010 FLORIDA BUILDING CODE: ACCESSIBILITY 7. FLORIDA FIRE PREVENTION CODE, 2010 8. NATIONAL ELECTRIC CODE, 2008 FLORIDA BUILDING CODE — BUILDIN OCCUPANCY TYPES: FBC CHAPTER 3 (309.1) : MERCANTILE — M CONSTRUCTION TYPES: FBC, TABLE 503 TYPE IIB / UNPROTECTED / UNSPRINKLED ACTUAL BUILDING HEIGHT: 1 STORY ACTUAL TENANT AREA: 1,600 S.F. FBC, SECTION 709.1.6: TENANT SEPERATION — 1 HR. FBC, TABLE 1004.1.1 —OCCUPANCY LOAD REQUIREMENTS: AREA PER OCCUPANT: MERCANTILE GRADE FLOOR: 30 S.F. / OCCUPANT TENANT AREA 1600 S.F. / 60 SF PER OCCUPANT = 53 OCCUPANTS FBC, SECTION 1008.1.2 — DOOR SWINGS (EXCEPTION 1) . FBC, TABLE 1015.1 — EGRESS WIDTH REQUIREMENTS: EGRESS WIDTH PER PERSON SERVED —GROUP M: 0.2 INCHES NUMBER OF EGRESS EGRESS OCCUPANTS REQUIRED PROVIDED 48 X 0.2 9.6INCHES 34INCHES FBC, TABLE 1016.1 — EXIT ACCESS TRAVEL DISTANCE: MAXIMUM DISTANCE OF TRAVEL — GROUP M: UNSPRINKLED — 200 FT. FBC, SECTION 1018.2.2 — MINIMUM CORRIDOR / AISLE WIDTH REQUIRED: GROUP M: 36 INCHES (OCCUPANCY UNDER 50) FBC, SECTION 1018.3 — MAXIMUM DEAD END CORRIDOR: 20 FT. FPC TABLE 403.1 — PLUMBING FIXTURE REQUIREMENTS FIXTURE REQUIRED PROVIDED WATER CLOSETS (EXISTING) 1 / 500 1 LAVATORIES (EXISTING) 1 / 750. 1 DRINKING FOUNTAINS (EXISTING) 1 / 1000 EXCEPTION BATHTUBS / SHOWERS — N/A NFPA 101 — OCCUPANT LOAD SIGN SHALL BE POSTED STATING MAXIMUM OCCUPANCY FOR SPACE. FFPC — LSC 42.1.1 AND 43.1.2 — CLASSIFICATION OF WORK: MODIFICATION FLANS E.(Ap I DRAWING SYMBOLS 120 ROOM NUMBER 20 DOOR NUMBER 20 WINDOW NUMBER DATUM ELEV. W1 DEMOLITION NOTES 01 WALL TYPE N W IE1 E INTERIOR ELEVATION NUMBER Ax SHEET NUMBER REFERENCE S NE EXTERIOR ELEVATION NUMBER AX SHEET NUMBER REFERENCE DETAIL NUMBER D1 AX SHEET NUMBER REFERENCE S1 WALL SECTION NUMBER AX SHEET NUMBER REFERENCE A BUILDING SECTION NUMBER AX SHEET NUMBER REFERENCE COLUMN GRID DESIGNATION C1 — Al REVISION CLOUD AND SYMBOL DESIGNATION WALL TYPES EXISTING STUD WALLS NEW METAL STUD WALL = — - 1 HR. F.R. METAL STUD WALL 2 HR, F.R. METAL STUD WALL EXISTING C.M.U. BLOCK WALL INDEX TO DRAWINGS. - ARCHITECTURAL C — COVER AO — EXISTING FLOOR PLAN — TENANT SPACE LS — LIFE SAFETY PLAN Al — EQUIPMENT PLAN & SCHEDULE A2 — FLOOR PLAN & DOOR / WINDOW SCHEDULE DETAILS A3 - WALL SECTIONS & FRAMING NOTES A4 — FIRE RATED ASSEMBLY DETAILS A5 — ROOF EQUIPMENT PLAN & DETAILS A6 — RELECTIVE CEILING PLAN & DETAILS A7 — INTERIOR FINISHES & GRAPHICS PLANS A8 — TOILET ROOMS & INTERIOR ELEVATIONS A & B A9 — INTERIOR ELEVATIONS C, D & E All —INTERIOR ELEVATIONS F,G & H MECHANICAL M 1 — HVAC PLAN M2 — HOOD SCHEDULES M3 — FAN SCHEDULES M4 — HOOD ELEVATIONS ni I I<♦ADIAIl� P1 — SANITARY PLAN AND SANITARY RISER P2 — DOMESTIC WATER RISER P3 — GAS PLAN & RISER ELECTRICAL E1 — POWER & LIGHTING PLANS E2 — ELECTRIC PANEL SCHEDULES AND RISER DIAGRAM FIRE RATED DETAILS FR1 — FIRE RATED PENETRATIONS DETAILS SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT, THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR & MR. JOSHUA LINCOLN ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA COVER c •Z'17 NORTH SITE PLAN NO SCALE DEL OLMiEDO ARC015027 Iw SIDEWALK CURB - - - - - - - - - I11 1 /2"0 WATER LINE & HOSE BI B 3'-8 C/) C/) cl-) cf) O O O O Q <c <c a m m m m wl wl wl w w w w w 0 N R TU o STEEL GIRDER TRUSS 24'-0 3/8" 2- 13 "0 PVC FOR 4'-3 3/8" I ELECTRICAL I I I I I RF:-^AOVE FLQURSCENT ITS. , Q I I I I I I Of 0 rig EMOVE FL URSCENT L S. I 1 -2" 3'-4" 10 -0" I I I I I Ki4 - - - - - - - - - - - - - - - - - - - - - - I I 24'-7 1 /2" - - - - - - - - - - - - - - - - - - - - - - - J FLOOR PLAN -EXISTING \_ LEASABLE GROSS AREA - 1,600 S.F. 0 I CV 6"k6" STL 1 /4" = 1'-0" 00 I (V COL. GENERAL NOTES - DIVISION 1 GENERAL REQUIREMENTS 1. THE INTENT OF THESE DOCUMENTS IS TO PROVIDE FOR THE CONSTRUCTION OF THIS PROJECT, COMPLETE AND FUNCTIONAL IN ALL RESPECTS. THE .CONTRACTOR SHALL BE RESPONSIBLE FOR THIS RESULT. THE OMISSION OF EXPRESS REFERENCE TO WORK NECESSARY AND REASONABLY INCIDENTAL FOR THE COMPLETE CONSTRUCTION OF THE PROJECT SHALL NOT BE CONSTRUED AS RELEASING THE CONTRACTOR FROM HIS RESPONSIBILITIES. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, CLEARANCES AND CONDITIONS TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. FAILURE TO DO SO CONSTITUTES ACCEPTANCE AND RESPONSIBILITY FOR ALL EXISTING CONDITIONS. THE CONTRACTOR WILL NOT BE ALLOWED ADJUSTMENTS IN THE TIME OR MONEY REQUIRED TO RECTIFY THE SITUATION. 3. DO NOT SCALE DRAWINGS. GIVEN DIMENSIONS SHALL GOVERN. LARGE SCALE DRAWINGS SHALL GOVERN OVER SMALL SCALE DRAWINGS. 4. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL PURCHASED, FABRICATED AND FINISHED ITEMS FOR REVIEW BE THE ARCHITECT UNLESS WAIVED BY THE SAME. 5. ALL EQUIPMENT, MATERIALS AND ARTICLES INCORPORATED INTO THE PROJECT SHALL BE NEW AND UNDAMAGED. ALL WORKMANSHIP SHALL BE WITHIN INDUSTRY STANDARDS. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR AND REPLACEMENT OF DAMAGE TO AREAS CAUSED BY HIS WORK AT NO ADDITIONAL COST TO THE OWNER. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY CONDITIONS RELATING TO JOB CONSTRUCTION INCLUDING A SAFE ENVIRONMENT FOR OCCUPANTS OF AREAS ADJACENT TO THE WORK AREA. 8. THE CONTRACTOR SHALL PAY ALL FEES FOR PERMITS NECESSARY FOR PROPER COMPLETION OF WORK, UNLESS NOTED OTHERWISE. 9. SHOULD THE CONTRACTOR OBSERVE ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, HE SHALL PROMPTLY NOTIFY THE ARCHITECT REQUESTING CLARIFICATION. THE CONTRACTOR SHALL NOT PROCEED WITH WORK AFFECTED BY SUCH ERRORS, DISCREPANCIES OR OMISSIONS WITHOUT RECEIVING CLARIFICATIONS. ADJUSTMENTS INVOLVING SUCH CONDITIONS MADE BY THE CONTRACTOR WITHOUT PRIOR CLARIFICATION BY THE ARCHITECT, SHALL BE AT THE CONTRACTOR'S OWN RISK. COMPLICATIONS ARISING FROM PROCEEDING WITHOUT CLARIFICATION SHALL BE RESOLVED AT THE CONTRACTOR'S EXPENSE. 10. ALL WORK PERFORMED ON THIS PROJECT SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES, LAWS AND ORDINANCES. 11. ANYTHING IN THE CONTRACT DOCUMENTS NOT WITHSTANDING, THE CONTRACTOR ACCEPTS THE RESPONSIBILITY OF CONSTRUCTING A WATERTIGHT, WEATHER TIGHT PROJECT. 12. CONTRACTOR SHALL COORDINATE LOCATION OF ALL NEW ROOF MOUNTED EQUIPMENT WITH OWNER PRIOR TO INSTALL. CENTER EQUIPMENT OVER BEAM OR COLUMN UNLESS DIRECTED OTHERWISE BY OWNER. 13. CONTRACTOR SHALL PROVIDE 2x BLOCKING AT ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES. 14. ALL SIGNS, INCLUDING WINDOW SIGNS, TO BE SUBMITTED FOR REVIEW AND APPROVAL UNDER SEPARATE PERMIT BY OWNER/CONTRACTOR. 15. ALL ANGLES AT 45° OR 90' UNLESS OTHERWISE NOTED. DIVISION 2 DEMOLITION; HAZARDOUS MATERIALS 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED TO ALLOW FOR ALL PROPOSED NEW WORK. 2. PATCH, REPAIR, REPLACE AND FINISH ANY FLOOR, WALL OR CEILING TO MATCH ADJACENT AREAS WHERE DEMOLITION HAS BEEN REQUIRED. 3. PROVIDE PROPER SHORING AND DISCONNECTION OF ALL UTILITIES PRIOR TO DEMOLITION. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE SITE FREE OF DEBRIS. 5. THE CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER PRIOR TO START OF WORK, THE REQUIREMENTS FOR CORING OF FLOOR SLAB FOR ALL REQUIRED WORK. 6. THE ARCHITECT AND ENGINEERS, AND CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES. 8. COMPLY WITH APPLICABLE CODES AND/OR ORDIANCES CONCERNING DEMOLITION OPERATIONS, REFUSE REMOVAL, AND DISPOSAL. DIVISION 3 CONCRETE 1. CLEAN, GRIND AND FILL EXISTING CONCRETE TO ACCEPT VINYL TILE, CARPER, OR CERAMIC TI LE. 2. FLOORS TO RECEIVE TILE OR SHEET VINYL SHALL NOT VARY MORE THAN 1 /4" PER 10 FT. DIVISION 5 METALS 1. STEEL FRAMING: WITH EACH TYPE OF METAL FRAMING REQUIRED, PROVIDE MANUFACTURER'S STANDARD STEEL RUNNER, BLOCKING, LINTELS, CLIP ANGLES, SHOES, REINFORCEMENTS, FASTENERS AND ACCESSORIES AS RECOMMENDED BY THE MANUFACTURER FOR THE APPLICATIONS INDICATED. 2. METAL STUDS: OPEN BOX SHAPED SECTIONS, 3-1/2 INCH x 25 GAGE MIN. (20 GAGE FOR STUDS OVER 14'-0" IN HT. AND AT WALL AT WATER HEATER / MOP SINK ENCLOSURE). DIVISION 7 THERMAL & MOISTURE PROTECTION 1. ALL INSULATING MATERIALS IN CONCEALED SPACES HAVE A FLAME SPREAD RATING OF 75 OR LESS AN A SMOKE DEVELOPED RATING OF 450 OR LESS PER ASTM E84. DIVISION 8 DOORS & WINDOWS 1. ALL GLASS SUBJECT TO HUMAN IMPACT SHALL CONFORM TO THE STANDARD SET FORTH IN THE LOCAL BUILDING CODE. 2. ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. 3. MANUALLY OPERATED EDGE OR SURFACE -MOUNTED FLUSH BOLTS AND SURFACE BOLTS OR ANY OTHER TYPE OF DEVICE THAT MAT BE USED TO CLOSE OR RESTRAIN THE DOOR ARE PROHIBITED. WHERE EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC FLUSH BOLTS ARE USED, THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS SHALL HAVE NO DOORKNOB OR SURFACE -MOUNTED HARDWARE. THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. 4. PANIC HARDWARE, WHERE INSTALLED, SHALL COMPLY WITH THE LOCAL BUILDING CODE. THE ACTIVATING MEMBER SHALL BE MOUNTED AT 36 TO 44 INCHES ABOVE THE FINISH FLOOR. THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE DIRECTION OF TRAVEL. DIVISION 9 FINISHES 1.INTERIOR FINISHES TO HAVE A MAXIMUM FLAME SPREAD RATING OF 200 AND MAXIMUM SMOKE DEVELOPMENT RATING OF 450. 2. STUD PARTITIONS TO BE ANCHORED SO AS TO RESIST A LATERAL LOAD OF 5 PSF AS FOLLOWS, BOTTOM PLATE: ANCHOR TO SUB FLOOR WITH 300# POWER DRIVEN PINS AT 48" O.C. ICBO #1639 3. GYP BOARD WALLS TO BE TAPED, SANDED AND HAVE SMOOTH FINISH, UNLESS NOTED OTHERWISE. 4. THE CONTRACTOR SHALL PROVIDE AND INSTALL CAULKING WHERE NOT SPECIFICALLY PERFORMED BY OTHER TRADES. 5. CERAMIC TILE FLOORS SHALL NOT VARY MORE THAN 1 /4" PER 10 FEET. DIVISION 10 SPECIALTIES 1. SUITE NUMBER OR ADDRESS TO BE POSTED ABOVE DOOR. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION / MODIFICATION OF THE FIRE SPRINKLER SYSTEM. CONTRACTOR SHALL SUBMIT DRAWING TO GOVERNING AUTHORITY FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WITH WORK. DIVISION 15 MECHANICAL 1. VERIFY EXISTING MECHANICAL EQUIPMENT (HVAC) IS IN FULL WORKING ORDER, REPLACE FILTERS THROUGHOUT SYSTEM. 2. VERIFY FRESH AIR SETTING, HUMIDITY CONTROLS, BALANCE, ETC. ARE ADEQUATE FOR PROPOSED USE. REPLACE AND/OR MODIFY SYSTEM AS REQUIRED FOR COMPLIANCE WITH LOCAL GOVERNMENTAL AGENCIES REQUIREMENTS. ELECTRICAL LEGEND SYMBOL DESCRIPTION COMMENTS 3 - TUBE PRISMATIC (ACRYLIC) FLUORESCENT LT. LENSES FIXTURES A.C.T. GRID MNT. 24" X 48" PARABOLIC LENSES 3 - TUBE FIXTURES FLUORESCENT LT. A.C.T. GRID MNT. 34 TUBE PRISMATIC (ACRYLIC) FLUORESCENT LT. LENSES FIXTURES A.C.T. GRID MNT. 24" X 24" PARABOLIC LENSES 3 - TUBE FIXTURES FLUORESCENT LT. A.C.T. GRID MNT. DOUBLE TUBE FLUORESCENT LT. ® RECESSED CAN LT. CLG MNT SURFACE MOUNTED INCANDESCENT SURFACE MOUNTED PULL -CHAIN -(>PC INCANDESCENT SWITCH C CHANDELIER CEILING MOUNTED WALL MOUNTED INCANDESCENT 0 0 o TRACK LIGHTING CEILING MOUNTED INCANDESCENT LIGHT & FAN O O EMERGENCY LIGHT ® & EXIT LIGHT COMBO 0 EMERGENCY LIGHT ® EXIT LIGHT ® SPEAKERS WALL OUTLET 18" ABOVE FIN. FLR. 42" A.F.F. WALL OUTLET CLG CEILING MOUNT DUPLEX FOUR PLEX WALL OUTLET ez EXISTING OUTLET FIELD VARIFY ® DIRECT CONNECTION JUNCTION DISCONNECT ELECTRICAL PANEL SINGLE POLE SWITCH $2 SINGLE POLE TWO-WAY SWITCH n HVAC THERMO-STAT 42" A.F.F. �J WALL MOUNT 0 TELEPHONE DATA os OCCUPANCY SENSOR DELAY. WALL MOUNT SWITCH W/ TIME 42" A.F.F. os OCCUPANCY SENSOR CEILING MOUNT SWITCH W/ TIME Tc INTERMATIC TIME CLOCK FTF DJ. TO PWR PNL 600UA HVAC LEGEND A/C DIFFUSER CLG. VENT A/C RETURN AIR pVR4 CLG. GRILL ® EXHAUSTFAN CLG. VENT HVAC NOTE: ALL EXISTING HVAC SYSTEMS TO REMAIN, AS IS, U.N.O. ON DEMOLITIONS PLANS, AND / OR ALTERATION PLANS. FIRE PROTECTION �}E SPRINKLER HEAD O NEW OR RELOCATED SPRINKLER HEAD F.E. >0 FIRE-EXTINGUISHER ❑ FIRE -ALARM PULL STATION AUDIO / STROBE FIRE -ALARM COMBINATION EXISTING MECHANICAL & ELECTRICAL: EXISTING HVAC RTU TO REMAIN. DIMENSIONS: GENERAL CONTRACTOR TO FIELD VARIFY LOCATION OF PROPOSED NEW WALLS EQUIPMENT AND PLACEMENT, PRIOR TO START OF WORK. DIMENSION DISCREPENCY OR EQUIPMENT SHALL BE BROUGHT TO ARCHITECT'S ATTENTION FOR CORRECTION. SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL, 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN J�a 0 M� 1 . Suss ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA EXISTING FLOOR PLAN I NUMBER EL OLMEDO AR0015027 - - - - - - - li TF_ I _T LIFE SAFETY PLAN LONGEST DISTANCE TRAVELED TO EGRESS - 58'-2" OCCUPANCY CALCULATIONS TABLE 1004.1.2 - MAXIMUM FLOOR AREA ALLOWABLE PER OCCUPANT FUNCTION OF SPACE PLAN GRAPHIC SYMBOL OCCUPANCY CLASSIFICATN OCCUPANCY AREA CALC. AREA OCCUPANTS SEATING TABLES & CHAIRS ASSEMBLY 15 NET 268 S.F. 18 WORK / SERVICE AREA (KITCHEN) KITCHEN /STORAGE 200 GROSS 615 S.F. * * 05 WAITING AREA ASSEMBLY 7 NET 109 S.F. 14 TOTAL OCCUPANCY 37 ** DENOTES OCCUPANCY IN KITCHEN AREA, NOT PART TO NET AREA. OCCUPANCY SIGN POST: SIGN BELOW TO BE POSTED VISIBLE TO EMPLOYEES AND WALL MOUNT 6'-6" A.F.F. - 1 1 /2" HEIGHT LETTERING 3" HEIGHT LETTERING37 IN CONSPICUOUS SPACE PATRONS. SEE PLAN FOR LOCATIONS. MAXIMUM OCCUPANCY DOOR APPROACH CLEARANCES LATCH SIDE APPROACH NOTE: Y = 48" MIN. IF DOOR HAS CLOSER PULL SIDE FRONT APPROACH z PUSH SIDE NOTE: X = 12 MIN. IF DOOR HAS BOTH A o 00 CLOSER & LATCH LATCH SIDE APPROACH NOTE: Y = 54" MIN. IF DOOR HAS CLOSER „X„ PULL SIDE -0- TOILET SIDE APPROACH PULL SIDE z N r24',PREF RRED " M N 1-1 00 SEATING TABULATION TABLE 1004.1.2 - MAXIMUM FLOOR AREA ALLOWABLE PER OCCUPANT SYMBOL TABLE TYPE QUANTITY TOTAL SEATS I I I I I I I I I I I I BOOTH 1 00 TWO TOP 05 1 ' A.D.A. N 01 L-- -- —J TWO TOP I I I I FOUR TOP HIGH TOP BAR SEAT TOTAL SEATING >O FIRE EXTINGUISHER WALL MOUNT TYPES: ALL FIRE EXTINGUISHERS SHALL BE CLASS "A,B&C", AND KITCHEN FIRE EXTINGUISHERS SHALL BE CLASS "K" UNLESS NOTED OTHERWISE. NOTE: FIRE EXTINGUISHERS TO BE INSTALLED WITH A MAX. HEIGHT OF 5'-0" A.F.F AND A MIN. HEIGHT OF 4" A.F.F. INSTALLED WITH A MAX. HEIGHT CUSTOMERS A CUP OF WATER WILL BE SERVED UPON REQUEST. 11 Leff 01 10 m 16 11 11 30 DIMENSIONS: GENERAL CONTRACTOR TO FIELD VARIFY LOCATION OF PROPOSED NEW WALLS EQUIPMENT AND PLACEMENT, PRIOR TO START OF WORK. DIMENSION DISCREPENCY OR EQUIPMENT SHALL BE BROUGHT TO ARCHITECT'S ATTENTION FOR CORRECTION. A.D.A. -TABLE SEATING FBC 2010 - ACCESSIBILITY 1, 7„ --- JERSEY MIKE'S TABLE - \`\ WALL 60" I i L - -'-3�� \ i CENTER PRONG �� 48" NTER SUPPOR / I i I � � I° I cs� � I CD/4 I I I n I^ o \ z bl I^ n I^ I o-- 3r0 4 N I N I ts� I �I ` N 112" 12" I I 1 1-711 JERS Y MIKES TABLE 60" MIN. L - - - - - 01 L 36" PLAN VIEW PLAN VIEW RADIUS - MANUVERING PLAN VIEW T -MANUVERING 1�_�° MAX. TABLE TOP HT. MAX. TABLE TOP HT. MAX. TABLE TOP HT. Z CD rx z � b O ro i8s CV N sa'Z N ELEVATION VIEW ELEVATION VIEW ELEVATION VIEW SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR 8c MR. JOSHUA LINCOLN J� M. Suss ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA LIFE SAFETY PLAN NUMBER AUEL OLMEDO AR0015027 I• EQUIPMENT PLAN 1 /4" = 1'-0" EQUIPMENT SCHEDULE KEY QTY. ITEM NAME MANUFACTURER MODEL NUMBER SUPPLIER POWER REQUIRED PLUMBING REQUIRED MISC. NOTES 1 1 MARC MEATCASE MARC MDL-6SC ECO 12AMP 115V/60/1 NSF-7 2 1 SNEEZEGUARD C.R. LAURENCE GC C.R. LAURENCE 323-588-1281 X 7710 RICARDO BASULTO 3 1 4' DROP IN COLD UNIT DUKE ADI-2MDSL ECO 42 AMP 115V/115V/60/V NO DRAIN REQUIRED 3A 0 2' DROP IN COLD UNIT DUKE ADI-1MD ECO 42 AMP 115V/ 115V/60/V NO DRAIN REQUIRED 4 2 SLICER BIZERBA GSP—H33 W/LIFT ECO 120V/ 60/ 1 5 1 MENU BOARD JMFS JMFS GRAPHICS CO. ORDERED WITH GRAPHICS PACKAGE 6 1 TELEPHONE VARIES VARIES FRANCHISEE 2 LINE PHONE 7 2 CHIP DISPLAY UNIT FRITO LAY FRITO LAY BUILT WITH CABINETS 8 2 CASH REGISTER INFOSOFT UP700 FRANCHISEE REG. W/ COMM. MODEM, CASH DRAWER, RECEIPT & JOURNAL (2 SETS KEYS) 9 1 FAX MACHINE VARIES VARIES FRANCHISEE PLAIN PAPER FAX 10 1 BREAD OVEN NUVU UB—E5/ 10 AUTOMIST ECO 29AMP 208V/ 1 or 3ph OR 29AMP 240V/1 or 3ph Y4" SUPPLY LINE AUTO MISTER NOT OPTIONAL 11 54 BREAD PANS LINCOLN FOOD SERVICE SMALLWARES CO. 18 GAUGE SHEET PANS 12 2 BREAD RACK CHANNEL 401AC SMALLWARES CO. W/ (2)CURTAIN COVERS, WINDOW DISPLAY, ZIPPER 12A 1 BREAD RACK (STATIONARY) CHANNEL DE100517 SMALLWARES CO. W/ (2)CURTAIN COVERS, WINDOW DISPLAY, ZIPPER 13 1 HAND SINK — WALL HUNG CHG FS1 7D1 41005JM ECO CHG FKL45-4000—RE4 FAUCET WALL MOUNT HAND SINK W/ TWO 73/4" SIDE SPLASHES AND FAUCET 13A 1 HAND SINK — DROP IN CHG FS17_= 1014JM ECO CHG FKL45-4000—RE4 FAUCET DECK MOUNT HAND SINK WITH ONE 6" END SPLASH. VERIFY QUANTITY 14 1 3 COMPARTMENT SINK REUSE EXISTING OR UNIVERSAL/CHG 3N1620-2D18 ECO CHG KL53-1000—AF4 PRE—RINCE SPRAYER/ ADD —A —FAUCET, KL54-8012 FAUCET AND D50-7100 LEVER WASTES — QTY 3 IF TALLER THAN 9", END SPLASHES ARE REQUIRED 14A 0 3 COMPARTMENT SINK UNIVERSAL/CHG 3N1824-2D18 ECO CHG KL53-1000—AF4 PRE—RINCE SPRAYER/ ADD —A —FAUCET, KL54-8012 FAUCET AND D50-7100 LEVER WASTES — QTY 3 94" MODEL. IF TALLER THAN 9", END SPLASHES ARE REQUIRED 15 1 PREP SINK UNIVERSAL/CHG 1N1620—lD18 ECO CHG KL54-8002 FAUCET ONE COMPARTMENT SINK WITH DRAINBOARD ON EITHER THE LEFT OR RIGHT SIDE 16 VARIES WIRE SHELVING METRO ECO 2 TIER WALL SHELVES OVER SINKS & S/S TABLES, 4 TIER COOLER/FREEZER SHELVING & DRY STORAGE 17 1 1 DOOR PEPSI COOLER PEPSI GDM-26 PEPSI 18 1 WALK IN COOLER NORLAKE KLB-74__x_= C_= 36" ECO 115V FOR LIGHTS AND DOOR HEATER, 15 AMP BREAKER FLOORLESS, SPLIT REMOTE CAPSULE PAK SYSTEM 18A 1 CAPSULE PACK NORLAKE RCPF075—DCA ECO 208-230/ 60/ 1 ,8 TOTAL SYSTEM AMPS, 9.3 MINIMUM CIRCUIT AMPS, 15 MAX FUSE SIZE. POWER REQUIRED MAY VARY PER SITE— CONFIRM AMPS 19 1 STEP IN FREEZER NORLAKE KLF-77__x= C= 36" ECO 115V FOR LIGHTS AND DOOR HEATER, 15 AMP BREAKER WITH 4" STEP—UP FLOOR PANEL, SPLIT REMOTE CAPSULE PAK SYSTEM 19A 1 CAPSUL PACK NORLAKE CPF—__ __ __—DCA ECO 208-230/60/1, 14.9 DEFROST AMPS, 8.4 TOTAL SYSTEM AMPS, 14.9 MINIMUM CIRCUIT AMPS, 15 MAX FUSE SIZE POWER REQUIRED MAY VARY PER SITE— CONFIRM AMPS 20 1 MOP SINK EXIST CLEAN & REFUSE 2'X2' — Y2" SUPPLY 1)�" DRAIN, VENT MOP HANGER AND WALL GUARD 21 2 SANDWICH UNIT TRUE TSSU-27-8D-2 ECO 115V/60/1 W/ CASTERS 21A 0 MEGATOP SANDWICH UNIT DELFIELD D4427-12M ECO 115V/60/1 W/CASTERS AND COVER ENHANCEMENT 21B 0 SANDWICH UNIT DELFIELD D4427-9M ECO 115V/60/1 W/CASTERS AND COVER ENHANCEMENT 22 1 GRILLE IMPERIAL IR—G48T—XB—JMII ECO CONFIRM NATURAL OR LP GAS OPTION:CASTER, FLEX GAS HOSE, QUICK CONNECT & RESTRAINING DEVICE. BE SURE TO INCLUDE PERFORMANCE CHECK 23 1 EXHAUST HOOD SYSTEM & FIRE SYSTEM CAPTIVE AIRE ANSUL ECO (4) 115V FIRE SYSTEM ANSUL SHOP DRAWINGS MAY BE PROVIDED. CONTACT ROBERT McCLOUD AT ROBERT.MCCLOUD@CAPTIVEAIRE.COM AND/OR REG320CAPTIVEAIRE.COM 23A 1 CONDENSATE HOOD CAPTIVE AIRE 5424VHB ECO (1) 115V SHOP DRAWINGS MAY BE PROVIDED. CONTACT ROBERT McCLOUD AT ROBERT.MCCLOUD@CAPTIVEAIRE.COM AND/OR REG320CAPTIVEAIRE.COM 24 3 T.V.'S W/ MOUNTING BRACKETS VARIES 42" MONITOR FRANCHISEE/ GC 110 VOLT OUTLET AT CEILING, CEILING MOUNT BRACKETS 25 3 PORTABLE FIRE EXTINGUISHERS GC WALL MOUNTED 26 1 DRINK DISPENSER & ADAPTER KIT PEPSI DISPENSER: IDC215, ADAPTOR: 80002957 PEPSI 15 AMP 115V/60/1 Yz" SUPPLY, CONDENSATION DRAIN COORDINATE W/ PEPSI 27 j 1 FLOOR SAFE VARIES VARIES FRANCHISEE 28 1 ICED TEA BREWER BUNN TB3Q LUZIANNE 120V, 14.4 AMP 1-800-627-2094 29 1 MICROWAVE OVEN PANASONIC NE-17523 ECO 14.3 AMP 208/230-240 1700 WATT UNIT 30 1 MILLWORK OR S.S. TABLE 24"X36" UNIVERSAL --GLSB-24" OR GLSB-30" ECO OR GC IF MILLWORK VERIFY SIZE, S.S. (BY ECO) OR MILLWORK (BY GC) 31 1 COUNTER TOP FOOD WARMER APW WYOTT W-3V ECO 115V, 10.0 AMP 31A 1 COUNTER TOP COOKER/WARMER APW WYOTT CW-2A ECO 115V, 12.5 AMP 32 1 COUNTER SCALE CAS ED-30 ECO AC ADAPTER DC 12V/1A OR 12V/8OOmA, INTERNAL RECHARGEABLE SEALED ACID BATTERY — 6V DC SITS ON TOP OF MEATCASE 33 0 UNDER COUNTER DRAWERED REF. TRUE TUC-27D-2—LP ECO 34 1 BAG IN BOX SYSTEM PEPSI PEPSI PEPSI PROVIDE WATER LINE — SEE PLUMBING PLANS 35 1 REFUSE CONTAINER ATS 23"X23" FURNITURE CO. 36 5 TABLE TOPS ATS 24"X24" FURNITURE CO. 37 5 TABLE TOPS ATS 24"X42" FURNITURE CO. 38 10 TABLE BASES ATS BLACK CRINKLE FURNITURE CO. 39 30 CHAIRS ATS NATURAL OAK FURNITURE CO. 40 1 WATER HEATER GC 41 1 ICE MAKER HOSHIZAKI KM-515MAH ECO 115V/60 20 AMP BREAKER PROVIDE DRAIN 43 1 PAY HERE SIGN JMFS JMFS GRAPHICS CO. 44 1 ORDER HERE SIGN JMFS JMFS GRAPHICS CO. 45 0 BOOTH ATS FURNITURE CO. 46 0 PICK UP SIGN JMFS JMFS GRAPHICS CO. 47 0 BAR STOOL ATS FURNITURE CO. 48 1 DOOR SIGN/ LOGO JMFS JMFS GRAPHICS CO. 49 1 RED PHONE JENNE 255447—VBA-20MC (RED) FRANCHISEE CONTACT MICHAEL NORI, MNORI@JENNE.COM, 440-471-3109 50 5 TRACK LIGHTS HERMITAGE LIGHTING R701HW/ R2HW/ R4HW GC CONTACT WYATT CULVER, 615-843-3385 51 1 COMMUNITY BOARD BANGOR CORK JMFS FRANCHISEE CONTACT PETE RAINES, 610-863-9041 54 1 STANCHIONS VISIONTRON VS301 (BLACK) FRANCHISEE WWW.CROWDCONTROLWAREHOUSE.COM, SINGLE LINE 7-5' 55 6 CEILING MOUNTED SPEAKERS SOURSE 1 DISTRIBUTORS 770-977-5774 56 1 TROUGH 24" LONG X 4" WIDE TROUGH WITH SIDE SQUEEGE ATTACHMENT 57 0 BAR HEIGHT COUNTER BY CONTRACTOR — AS APPLICABLE BUILD ON SITE 58 2 BABY CHANGING TABLE SMALLWARES CO. TO BE INSTALLED IN WOMENS RESTROOM 59 0 LOCKERS ECO TYPICALLY ORDERED WHEN REQ'D BY HD 60 0 AIR CURTAIN BERNER W/TWO MICROSWITCHES ECO (1) 115V ALTERNATE EQUIPMENT SCHEDULE KEY QTY. ITEM NAME MANUFACTURER MODEL NUMBER SUPPLIER POWER REQUIRED PLUMBING REQUIRED MISC. NOTES 3 0 4' DROP IN COLD UNIT DELFIELD N8148—EFN ECO 115V/6OHz/1 W/NSF CERTIFICATION. NO DRAIN REQUIRED 3A 0 2' DROP IN COLD UNIT DELFIELD N8118—EF ECO 115V/6OHz/1 W/NSF CERTIFICATION. NO DRAIN REQUIRED CHG KL53-1000—AF4 PRE—RINCE SPRAYER/ 14 0 3 COMPARTMENT SINK UNIVERSAL/CHG 3N1824-2D18 ECO ADD —A —FAUCET, KL54-8012 FAUCET AND IF TALLER THAN 9", END SPLASHES ARE REQUIRED D50-7100 LEVER WASTES — QTY 3 CHG KL53-1000—AF4 PRE—RINCE SPRAYER/ 14A 0 3 COMPARTMENT SINK UNIVERSAL/CHG JM-3N1620-2D18SP ECO ADD —A —FAUCET, KL54-8012 FAUCET AND IF TALLER THAN 9", END SPLASHES ARE REQUIRED D50-7100 LEVER WASTES — QTY 3 FASTTRAK COOLER FLOORLESS, REMOTE SPLIT CAPSULE PAK SYSTEM. VERIFY PRECHARGED 18 0 WALK IN COOLER NORLAKE 74_x_= C_= 36" ECO 115V FOR LIGHTS AND DOOR HEATER, 15 AMP BREAKER REFRIGERATION LINE SET LENGTH, 115V ELEC. VAPORIZER PAN REQ'D OR HARD DRAIN LINE BY OTHERS 208-230/ 60/ 1 ,8 TOTAL SYSTEM AMPS, 9.3 MINIMUM BASED ON COMPARTMENT SIZE. POWER REQUIRED MAY VARY PER SITE — 18A 0 CAPSULE PACK NORLAKE RCPB—__ __ _= DCA ECO CIRCUIT AMPS, 15 MAX FUSE SIZE. CONFIRM AMPS FASTTRAK FREEZER WITH 4" STEP—UP FLOOR PANEL, REMOTE SPLIT CAPSULE PAK SYSTEM. 19 0 STEP IN FREEZER NORLAKE 36" ECO 115V FOR LIGHTS AND DOOR HEATER, 15 AMP BREAKER VERIFY PRECHARGED REFRIGERATION LINE SET LENGTH, 115V ELEC. 77_x_= C_= VAPORIZER PAN REQ'D OR HARD DRAIN LINE BY OTHERS 19A 0 CAPSUL PACK NORLAKE RCPF—__ DCA ECO 208-230/60/1, 14.9 DEFROST AMPS, 8.4 TOTAL SYSTEM BASED ON COMPARTMENT SIZE. POWER REQUIRED MAY VARY PER SITE — __ _= AMPS, 14.9 MINIMUM CIRCUIT AMPS, 15 MAX FUSE SIZE CONFIRM AMPS COMBINATION COOLERS ARE DEPENDENT ON SIZE AND CONFIGURATION- CUSTOM MODELS ARE FASTTRAK OR FINELINE. CONTACT DANAILIZZIE AT EVI FOR FURTHER SPECIFICATION SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR 8c MR. JOSHUA LINCOLN ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA EQUIPMENT PLAN PLAN SUET NUMBER Iit SAM L OLMEDO AR0015027 00 rn n 00 \ 0 L co n C) LO 0 I FLOOR PLAN —ALTERATIONS 1 r:ACARI 1= rr[?nec ADD=A - i Ann c P: 1 /4" = 1'-n" DOOR SCHEDULE . A L INTERIOR DOORS BY " AMERICAN DOOR COMPANY" OR EQUAL. 2. ALL EXTERIOR DOORS BY " UNITED STATES METAL MANUFACTURER CORP."OR EQUAL. MARK TYPE SIZE THK FRAME DOOR MATERIAL DETAIL HARDWARE REMARKS 01 A 3070 EXISTING EXSTG EXSTING EXSTING NEW OR UNDER RUNLOCKED DURING EP RATE PERMT,BBYINESS LANDLORDRS 02 C 3070 EXISTING EXSTG EXISTING EXISTING — EXISTING PANIC HARDWARE MECHANISM TO UNLOCK DOOR IN THE EVENT OF AN EMERGENCY EXIT W.L. PRESSURE 20.9# & —23.6# FLORIDA PRODUCT APPROVAL — (Curries) FL11537 03 D 3026 1 1 /4" — ALUMN. H2/J2 HW#3 04 B 3070 1 1/2" F1 SOLID CORE HW#2 DOOR TYPES FRAME TYPES S-0" 0 T II I N N I D ALUMN. ELIASON DOOR A B C IN SUGAR COOKIE " INSUL. ALUMN. SOLID CORE WOOD HOLLOW CORE MARLITE WAINSCOT ON 4- F1 STORE FRONT FLUSH PANEL FLUSH PANEL CUSTOMER SIDE 36W x 30H SINGLE DOOR BIRCH. FINISH INSULATED PART # LWPCF — STEEL FRAME AS PER J.M. RH 36JMIKE PAINT RICH CHESTNUT SEMI —GLOSS DOOR HARDWARE SCHEDULE HARDWARE SET #1: DOUBLE ENTRANCE DOORS LOCKSETS AND KEYING 2 SET SINGLE ACTING OFFSET PIVOT HINGES 2 DOOR CLOSER — NORTON 1605 SURFACE CLOSER FINAL CORE PROCESS FOR LOCKSETS AND KEYING: 1 4" EXTRUDED — MILL FIN. ALUM. THRESHOLD —A.D.A. (OFFSET PIVOT & OVERHD CLOSER) 1. THE SUBCONTRACTORS WILL INSTALL ALL DOORS, FRAMES, 1 DEADLOCK/LATCH COMBINATION WITH LATCH PADDLE DEVICE HARDWARE AND LOCKSETS AND ENTRANCE DOORS. 1 CYLINDER — 7 PIN MORTISE FINISH TO MATCH DOOR 1 WEATHERING SYSTEM AND EPDM BLADE SURFACE ATTACHED SWEEP STRIP 1 TOP AND BOTTOM FLUSH BOLTS HARDWARE SET #2: LOCKSET FOR INTERIOR DOORS HARDWARE NOTES 1 1/2 PAIR 3 1/2" x 3 1/2" BUTT, FULL MORTISE, FINISH US 26D 1. ADJUST ALL CLOSERS TO A 5 LB. MAX. OPENING FORCE. 1 EACH LEVER TYPE PRIVACY LATCHSET, FINISH US 26D 1 EACH DOOR STOP, FINISH US 26D 2. CONTRACTOR TO SUBMIT TYPE WRITTEN SHOP DRAWINGS AND PRODUCT 1 DOOR CLOSER — NORTON 1605 SURFACE CLOSER LITERATURE FOR ALL DOORS AND HARDWARE SPECIFIED. PREPARED BY A LICENSED AND CERTIFIED CONSULTANT. HARDWARE SET #3: LOCKSET FOR INTERIOR DOORS FULL HINDGE, DOUBLE ACTING 3. ALL EXTERIOR HOLLOW CORE METAL DOORS ARE TO BE INSULATED. DOOR AND FRAME TO BE SHOP PRIMED AND PAINTED. HARDWARE SET #4: LOCKSET FOR INTERIOR DOORS 4. ALL LOCK AND PASSAGE SETS TO BE SCHLAGE GRADE OR BETTER. 1 1/2 PAIR 3 1/2" x 3 1/2" BUTT, FULL MORTISE, FINISH US 26D SUBMIT OTHERS FOR APPROVAL. LOCKS NEED TO BE REKEYABLE. 1 EACH LEVER TYPE PASSAGE LATCHSET, FINISH US 26D 1 EACH DOOR STOP, FINISH US 26D 5. DOOR DETEX SYSTEMS MUST BE IN COMPLIANCE WITH SPECIAL EGRESS CONTROL DEVICES LISTED IN LOCAL CODES. 1 DOOR CLOSER — NORTON 1605 SURFACE CLOSER HARDWARE SET #5: LOCKSET FOR INTERIOR DOORS 6. SUBMIT DETAILED HARDWARE SCHEDULE FOR ARCHITECT'S APPROVAL. 1 1/2 PAIR 3 1/2" x 3 1/2" BUTT, FULL MORTISE, FINISH US 26D 7. ALL DOORS AND HARDWARE TO COMPLY WITH N.F.P.A. 101-5-2.1.5. 1 EACH LEVER TYPE KEY LOCK, FINISH US 26D 1 EACH DOOR STOP, FINISH US 26D 8. ALL DOORS AND HARDWARE TO COMPLY WITH A.D.A. AND CODE OF 1 DOOR CLOSER — NORTON 1605 SURFACE CLOSER FEDERAL REGULATION, UTILIZING A LEVER LATCH OR LOCKSET. _z Q= U cn 00 H W J Q co O = co f— Cf) 12" 2" 3'-0" S.S. GRAB BAR 3-6" S.S. GRAB BAR I. 2'-0" I 12" I_ CONTROLS MOUNTED ON WIDE SIDE OF TOILET AREA 1�,-5" MIEN. 14" MIN, PROJECTION FROM WALL URINAL MIRROR MTD @ 40" A.F.F. TO BOTTOM OF FRAME LAV. 8" MIN. DEPTH x 30" MIN. WIDTH KNEE SPACE m OQ U-1 O� Q � _ ::�i c� 9" MIN. HIGH x 30" MIN. WIDTH TOE CLEARANCE WINDOW SCHEDULE MARK TYPE SIZE FRAME MATERIAL DETAIL REMARKS AO EXSTG ALUMN. S.F. INSULATE HOT WATER & DRAIN PIPES OPTIONAL CUP DISPENSER WINDOW /FRAME TYPES �1iil<llRr STUDS © 16" O.C. ONE LAYER EA. SIDE S, U.N.O. TYPE "X" FIRE RATED GYPBRD. (1) HOUR F.R.WALL ASSEMBLY INTERIOR DOOR AS PER SCHED. 16 GA. GALV. H.M. FRAME PAINT FIN. HI /Jl DOOR HEAD JAMB DETNL MAX. HEIGHTS CLOTHES RODS SHELVES THERMOSTATS CONTROLS COUNTERS X Q X JW Q —w a I - Z X Q U> Q� �O Lnz� Zow 00 Cow0 O r7JU T.S. COVER DISPENSER 60" FLEX HOSE W/ SPRAY WAND DRYER PAPER TOWEL DISPENSER SWITCHES — THERMOSTAT FIRE ALARM - z CO co REE—STANDING OUNTAIN OR OOLER O ~Zw ��2 �zQ cc) � m SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR & MR. JOSHUA LINCOLN J� Ma � . Suss ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA FLOOR PLAN & DOOR / WINDOW SCHEDULE A2 SHE MBER q,0000f AU _ LMEDO AR0015027 TOP TRACK PER PLANS TEK TO FLANGE SNIP 6" WING AND BEND SIDE -TYP DOWN 90 DEGREES -TYP. 1 3 5/8"x1-1/4"x18Ga. TRACK TUDS ER PLANS -TYP TOP T�AC K CONNECTON 5TRUCTURAL DESIGN CRITERIA: 1. THE DESIGN COMPLIES WITH THE KEQUIKEMENT5 OF THE: A. FLORIDA BUILDING CODE 2007, 2009 REV1510N5 B. A15C MANUAL OF 5TEEL CON5TRUCT01N, ALLOWABLE 5TKE55 DE51GN 9 th. EDITION. C. A15I SPECIFICATIONS FOR THE DE51GN OF COLD -FORMED 5TEEL STRUCTURAL MEMBERS 1 98G. D. LIGHT GAGE STRUCTURAL IN5TITUTE 1990. 2. LOADINGS: A. D.L. =WT. OF MATERIAL=5 P5F WALL WT. B, L.L. = 20 P5F A. WIND LOAD = 120 MPH WIND SPEED - N/A 60OS162-4: AT TOP OF BRACING S W/ (4) 8 - 20 GA. (25 METAL STUD' U.N.O., SEE (INSULATE P TOILET ROON W/ R-11 BA 1 /2" GYP. I SIDE OF STI BASE FLOOR FINIS CONC. SLAB. 101j112.11 . BOT. TRACK j-� A I -A i 5/d" xl -1 /4­ x18Ga. I RACK V/ #10 TEK TO FLANGE :A. SIDE -TYP. 4) #10 TEKS TO ;EE EA. SIDE -TYP. STUDS PER PLA ROT. TRACK PEF GYP EA, SIDE TO FLANGE -TYP SHOTS Z TO SLAB - IYP. BOTTOM OF INTERIOR WALL I 0' (NON -LOAD BEARING) SECTION A -A INTERIOR HEADER DETAIL (FOR NON -LOAD BEARING WALLS) DED CLG. GRID 1C TI LE TOP TRACK PER PLANS SEE 7/- -TYP. STUDS PER PL BOTT. 1 J m"m1 . (IN SOME SITUATIONS WHERE GUN CAN'T FIT, TEKS WILL BE SCREWED FROM OTHER SIDE) FRAME WALL ASSEMBLY GID INSUL. ECKING DITION D STRUT SCREWED FOR -0" O.C. MAX :LF DRILLING SCREWS J.)� 1-1/2" 16 O.C. R PLANS =E SCHEDULE DN TENANT CE CHEDULE NEW FURR-OU 20 GA. (25 GE METAL STUDS WITH 1 /2" GYF U.N.O., SEE FL BASE FLOOR FINISH CONC. SLAB. T ,.MIN.), © 'B OCR tit SUSPEN ALUMN. ACOUSTI CEILING EXISTIN 5/8" T EACH SI FRAME TO EXIS rl EXISTING NUMATIC ANCHOR PIN 3-5/8" 16" O.C. D. PLANS METAL STUD NOTES: 1. STUD, TRACK AND ACCESSORY DESIGNATIONS ARE BASED UPON DIETRICH INDUSTRIES CATALOG. MINIMUM YIELD STRENGTH FOR 20 GA. AND 18 GA. STUDS SHALL BE 33 KSI; AND SHALL BE 50 KSI FOR 16 GA. AND 14 GA. STUDS. ALL TRACK SHALL BE 33 KSI. WIND STRAPS ARE BASED ON THE USE OF 40,000 P.S.I. FY MIN. 2. ALL STUDS, TRACK, BRIDGING AND ACCESSORIES SHALL BE FORMED FROM STEEL HAVING A G-60 GALVANIZED COATING MEETING THE REQUIREMENTS OF A.S.T.M. A525. 3. BOTH STUD FLANGES MUST BE ATTACHED TO TRACK AT TOP AND BOTTOM W/ #6x7/16" SIDS ON EA. SIDE FOR THE 18 GA. STUDS. 4. ALL COLD -FORMED STRUCTURAL 5TEEL MEMBER5 SHALL BE IN COMPLIANCE WITH THE 5PECIFICATION5 FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS THE LATE5T EDITION AND ALSO SHALL COMPLY WITH THE LIGHT GAGE STRUCTURAL INSTITUTE AND DE51GN HANDBOOK ESTABLISHED 1900. 5. CLIP PLATES AND ANGLE5 FOR COLD -FORMED 5TEEL 5TRUCTUKAL CONNECTIONS SHALL BE A5TM A 44G I GGA.. (U.N.O.). ALL OTHER COMPONENTS, ANGLES, ATTACHMENTS, PARTS, AND ADDITIONAL FRAMING MEM5ER5 ARE SUPPLIED AND DESIGNED BY OTHER5. G. COLD -FORMED 5TEEL 5TKUCTURAL CONNECTIONS U51NG TEK 5CKEW5 ARE A5 5HOWN THESE DRAWINGS. ADD. FIELD TEK5 MAY BE RQD. FOR STD. INSTALLATION. 7. HORIZONTAL BRIDGING: a). THE STRUCTURAL WALL STUDS SHALL BE CONTINUOU5LY BRACED AT MINIMUM 5'-0" VERTICAL POINT5. AND A5 SHOWN ON TRU55 DE51GN DRAWINGS. 8. COLD FORMED STRUCTURAL STEEL: THICKNE55 5HALL BE A5 FOLLOWS: 5TEEL DE51GN GA. THICKNE55 12 .104G 14 .0747 I G .0598 18 .0478 20 .0359 25 .0287 9. IN5TALL ALL 5TRAP TIES, ANCHORS, AND BRIDGING, ETC.., PER MANUFACTURE'5 IN5TALLATION5 REQUIREMENT5. 10. DIMENSIONS SHOWN ON TH15 5ET OF PLAN5 AKE TAKEN OFF AND DERIVED FROM THE ARCHITECTURAL DRAWING5 AND LAYOUT. FIELD VERIFY A5 BUILT STRUCTURE DIMENSIONS FOR CORRECT IN5TALLATION OF THE WALL 5Y5TEM5. G.C. 5HALL 5UPPLY THE MANUFACTURER WITH FIELD DIMENSIONS BEFORE FABRICATION IF DIFFERENT FROM THE ARCHITECT'S PLANS, OR THESE PLANS. 1 1 . ALL 5PLICE5 MU5T LAP A MINIMUM OF 1 2" FOR TOP TRACKS AND CONNECT WITH (4) #G TEK SCREWS ON EACH FLANGE 51DE. ED ',LG. GRID FILE ONE (1) LAYER :)E "X" GYP. BIRD. )E OF MTL. 20GA. 3-5/8" STUDS (ALL EXTENDED FROM SLAB 'G UNDERSIDE OF ROOF DECK cn w a > cn w > mi o N LINE OF GYPBRD. SOFFIT 3/4" CORIAN CAP "SAHARA" COLOR 20 GA. (MIN.), 5-5/8" METAL STUDS © 16" O.C. 1 /2" GYP. BIRD. EACH SIDE OF WALL BASE BOARD NEW REINF. CONC. SLAB. SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR & MR. JOSHUA LINCOLN M0 � . Suss ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA WALL SECTIONS & FRAMING AND NOTES 3 NUMBER 1 I ANTERIOR WALL PARTITION 2 EXISTING INTERIOR CMU WALL SECTION 3 EXISTING ONE HOUR WALL SE CTION n HALF WALL SECTION MUEL OLMEDO A'R0015027 i ONE &TWO HOUR WA - LL ASSEMBLY DESIGN SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN J� M. SUBS , ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA FIRE RATED ASSEMBLY DETAILS /AMEL OLMEDO AR0015027 - - - -- NEW FREEZER CONDENSER RC REMOTE CAPSU ROOF EQUIPMENT PLAN V WALK IN COOLER JDENSER ROOF TOP UNIT 40TE CAPSULE PAK n" ANSUL HOOD EXHAUST 'PROX. LOCATION OF NEW HOOD FRESH —AIR OPENING FOR ,X. LOCATION OF NEW SCOPE OF WORK: ROOFING & EQUIPMENT CONTRACTOR VARIFY LOCATION OF PROPOSED NEW & EXISINTG EQUIPMENT AND PLACEMENT, PRIOR BID & TO START OF WORK. ALL WORK IS SUBJECT TO EXISTING FIELD CONDITIONS THAT MAY ALTER THE DESIGN OF THIS PROJECT. � VENT/PIPE FLASHING DETAIL NTS TALL PIPE OR CLOSED PIPE LINE 1" BOND BREAKER TAPE 3" MIN. BUTYL SEALANT TAPE BONDED SECURELY TO BOTH SURFACES 4 LB. LEAD FLASHING 2 STRIPPING PLIES SET IN ASPHALT ROOFING MATERIAL OVER RIGID INSUL W/ COVER BOARD 2x SOLID BLOCKING STACKED W/ DRILLED HOLE FOR PIPE PENETRATION SEALANT @ PENETRATION 2 VENT /PIPE FLASHING DETAIL NTS i� 1/2" MIN. �♦ / UNIT , r 1" MIN. I I I i FLASHING j RECEIVER t � WOOD NAILER -NOMINAL 2" X 4" 3-1/2" MINIMUM METAL FRAME SEALING MATERIAL J CONTINUOUS z FLASHING RECEIVER 0� z z o2 COUNTERFLASHING NOTE: CURBS FOR RTU'S AND FANS FURNISHED AND ° ° INSTALLED BY MECHANICAL 00 CONTRACTOR ° ° ---BASE FLASHING o m / FASTENERS AT 8"O.C. INSULATION FIBER CANT STRIP -SET IN BITUMEN SIMPSON CS20 @ 18" O.C. W/ 4 — #8 SCREWS INTO CURB AND 2 — HILTI X—DNI 19PB P.D.F. INTO ANGLE 3 TYPICAL ROOF CURB FLASHING DETAIL NTS NOTES: 1. VERIFY ROOF CONDITIONS PRIOR TO WORK. 2. ALL PENETRATIONS SHALL BE COORDINATED WITH ROOF MFR. SPEC. & WARRANTY REQUIREMENTS. 3. ALL NEW ROOF LOADED EQUIPMENT SHALL BE VERIFIED BY A STRUCTURAL ENGINEER FOR LOADING REQUIREMENTS. 4. ALL EXHAUST AND SUPPLY ROOF VENTS SHALL BE LOCATED TO MEET ALL CLEARANCE REQUIREMENTS BY CODE AND MANUFACTURER REQUIREMENTS PRIOR TO INSTALLATION. EQUIPMENT RE: MECH. ONE PIECE 18 GA. GALV, SHEET MTL. CAP ON 3/4" PLYWD. & TREATED 2x8'S @ 12" ON CENTER SLOPE CAP TO DRAIN PREFORMED CANT STRIP L 2X BLOCKING SCREWS WITH - z NEOPRENE @ASHERS 12'"OC PATCH & MATCH \ VERIFY SIZE EXIST. ROOF WITH MECH. CONTRACT LI05T:1 I.T001II 4 MECH. EQUIPMENT PLATFORM N TS REFRIGERANT PIPING, ROUTE TO AHU, SIZE PER MFR'S REQUIREMENTS 3/8" ANCHOR BOLT UNIT TO (MIN 4 POINTS) ROOFTOP UNIT ANCHORING OPTION SIMPSON CS48 TYPICAL OF FOUR CONDENSING UNIT (1) PRE —MANUFACTURED CURB TO BEAR ON DECK (BY OTHERS). ROOFING SYSTEM EVENLOPE INSULATION 4__ ROOF MTL DECK'G NEW STRUCTURAL MTL ANGLE STRUT SUPPORTS AS PER SCHEDULE DETAIL #6/A5 SIMPSON CS20 @ 18" O.C. W/ 4 — #8 SCREWS INTO CURB AND 2 — HILTI X—DNI 19P8 P.D.F. INTO ANGLE 5 ROOF TOP PACKAGED ANCHOR DETAIL NTS HVAC FRAME (SEE NOTE #1) 3/16" TIP. 3 16' SEE PLAN FOR LOCATION I w z — 1 01 B G (CTR TO C R) HVAC FRAME REFER TO NOTE #2 FOR ADDITIONAL BRACING EXISTING BAR JOIST JOIST ELEVATION SECTION X-X HVAC FRAME SCHEDULE UNIT WT. "L" OR "W" REMARKS 4'— 0 5'— 0 6 —0 7 —0 1500 # L3X3X1 4 L3X3X1 4 L4X4X1 4 L5:5X1 4 2!1500 # L3X3X1 4 L3X3X1 4 L4X4X1 4 L5:5X1 4 _>2000 # L3X3X5 16 L3X3X1 4 L4X4X5 16 L5:5X5 16 —>2500 # L4X4X1 4 L4X4X1 4 L4X4X5 16 L5:5X5 16 —>3000 # L4X4X5 16 L4X4X3 8 L4X4X3 8 L5:5X3 8 >3000 #ISEE NOTE 4 SEE NOTE 4 SEE NOTE 4 SEE NOTE 4 L = LENGTH OF RTU L W = WIDTH OF RTU X LIN OF RTU --- --- -- 41 SEE NH AC �'� _3 a I I I ¢ TYP. m m I m 3/16" EXISTING BAR JOIST 7FRAME PLAN SECTION Y-Y NOTES: 1. STEEL FRAME TO BE PROVIDED AROUND THE WHOLE PERIMETER OF THE ROOF —TOP UNIT (RTC). FOR ASSEMBLY OF FRAME REFER TO FABRICATION DETAIL SHOWN. 2. PROVIDE L 2X2X1/4 EA. SIDE OF NEAREST PANEL PT. WHERE HVAC UNIT FRAME BRG. POINTS. ARE LOCATED. WELD TO TOP AND BOTTOM CHORDS TYPICAL. THISANGLE IS NOT REQUIRED IF UNIT IS LOCATED DIRECTLY OVER A JOIST PANEL POINT. 3. COORDINATE WITH MECHANICAL DRAWINGS FOR ACTUAL UNIT WEIGHTS AND OPENING SIZES. 4. SPECIAL ENGINEERING REQUIRED FOR UNITS WEIGHING MORE THAN 3000 POUNDS OR FOR FRAMING SPANNING MORE THAN 8'-0" 5. PROVIDE TIE —DOWN OF RTU'S TO STEEL AS PER MFR REQUIREMENTS. 6 R.T.U. FRAME SCHEDULE NOTES: (1) EXTEND PAD A MIN OF 4" BEYOND UNIT ALL AROUND (2) EQUIPMENT INSTALLATION TO MEET WIND PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE. (3) ALL ROOFING SYSTEM MEMBERS BY ROOFING CONTRACTOR. # 10 - Z" STAINLES" STEEL SCREW PRESSURE - TREATED WOOD SUPF PRESSURE - CONCRETE BRICK SILICONE ADHESIVE NTS J" GALVANIZED METAL STRAP 3/4"0 CPVC PIPE 1/8" PER FOOT SLOPE # 10 — J" STAINLESS STEEL SCREW ROOF 7 CONDENSATED SUPPORT DETAIL NTS SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL, 407.967.3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR 8c MR. JOSHUA LINCOLN h4lo �w Suss ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA ROOF EQUIPMENT PLAN & DETAILS 5 ET NUMBER i/I 4f ;'f I p L OLMEDO AR0015027 I I REFLECTIVE CEILING PLAN - ALTERATION 1 IA" _ 41_nn CEILINGS TAG SOURCE TYPE COLOR SIZE COMMENTS CT-1 ARMSTRONG ACOUSTICAL CEILING TILE VINYL FACED WHITE VINYL 2'X4' FOOD PREP AREAS EHD APPROVED VINYL FACED CT-2 ARMSTRONG ACOUSTICAL CELING TILE FINE FISSURED TECH WHITE 2'X4' THAT LOOK LIKE 2'X2' CUSTOM AREA S-1 GYPSUM SOFFIT PAINTED BENJAMIN MOORE WILMINGTON TAN, EGGSHELL PRODUCT # HC-34 SOFFIT ABOVE SERVICE COUNTER S-2 HARD CEILING GWB PAINTED BENJAMIN MOORE WHITE SEE PLAN, LIGHT FIXTURE IS CEILING MOUNTED 2'X4' OC-1 OPEN CEILING EXISTING FLAT BLACK DINING ROOM ONLY. FINISHES ARE EXTENDED TO 12'AFF - EVERYTHING ABOVE TO BE PAINTED FLAT BLACK. LIGHTING FDRURE (LUMINAIRE) SCHEDULE TYPE CATALOG NUMBER NO. LAMPS/TYPE WATTS VOLTS MOUNTING DESCRIPTION LUMINAIRE SCHEDULE NOTES: 1. ALL LIGHTING FIXTURES AND LAMPS IN THE ABOVE SCHEDULE ARE PROVIDED BY THE CONTRACTOR VIA A NATIONAL CONTRACT WITH HERMITAGE LIGHTING NATIONAL ACCOUNTS. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING THE LIGHTING FIXTURES. ANY QUESTIONS REGARDING FIXTURE AND LAMP TYPES AND INSTALLATION REQUIREMENTS SHALL BE WITH WYATT CULVER OF HERMITAGE LIGHTING AT (800) 264-33B3, OR (615) 843-3379. 2. RECESSED DOWN LIGHTS ARE AVAILABLE AS EITHER Cl, C2, OR C3 AS SPECIFIED BY OWNER. FOOD SAFE TRIM AVAILABLE AS NEEDED WHEN REQUIRED (PART #18622309) 3. TYPES W2 AND P2 ARE ALTERNATES FOR STORES IN CALIFORNIA AND OTHER STATES W/ WATTS/ SQFT RESTRICTIONS SUCH AS TITLE 24 O O O O © O A F /Z 5" O /^V 0 /Z I 45A /Z I CD SECTIONAL VIEW AXONIMETRIC VIEW OA WALL. © ONE VERTICAL SUPPORT 8" FROM WALL 4'-0" APART. © TWO #2 SPLAY WIRES PERPENDICULAR TO MAIN RUNNER. O TWO #2 SPLAY WIRES AT 12' O.C. EACH WAY. O OVER 56# FIXTURE SUPPORT DIRECTLY TO STRUCTURE. O UNDER 56# FIXTURE PROVIDE (2) #2 SLACK WIRES PLUS ATTACH 4 CORNERS TO GRID. © CLIP 4 CORNERS. O LIGHT FIXTURE OR CEILING DIFFUSER. O CROSS TEE: HEAVY—DUTY SYSTEM OF GRID/RUNNERS (FOR INTERMEDIATE— DUTY SYSTEM ADDITIONAL WIRES NECESSARY TO RUNNERS 3' FROM ALL FIXTURE CORNERS). IBC SEC. 803.9.1.1 AND ASTM C 635 & C 636. O SEISMIC COMPRESSION STRUT: 12'-0" O.C. 1 /2" RIGID STEEL CONDUIT TO BE PLACED OVER VERTICAL WIRE. CUT TUBE TO LENGTH LESS THAN OPEN SPACING. (IF REQUIRED BY LOCAL JURISICTION) TYPICAL CEILING GRID SUSPENSION FOR LAY -IN ACOUSTICAL PANELS C 5/8' STU [ 1 /2" SIDE 10 EXISTING E 9 GA. 6 WOE DS TIE —OFF TYP. EA. BOTT. CHORD & 3 5/8" MTL.1 STUD I I KITCHEN 0 CLG 0 p A. C. T. (KITCHEN SIDE) _ q � A.C.T. DETAIL NO SCALE OPTION: ANCHOR TO UNDER SIDE OF MTL. ROOF DECK p \ :.: 3-5/8" 20GA. METAL PAINT VERT WALL & HORZ. 0 O "C" CHANNEL CLG BLACK AS PER J.M. INT. FIN SCHED. \ OCI \ (4) #10 TEKS TO CEE EA. SIDE TYPICAL 12'- p O ;.; — — — — A.F.F. 0 ; DIAG. MTL STUD STRUTS @ 32"O.C. L— 4"' —' 20 GA. MTL. STUDS @ 16" O.C. 5/8" TYPR "X" GYPBRD SOFFIT LENGTH SEE PLAN JERSEY MIKE'S MURAL 1 /2" GYPBRD. 9'— 0» SOFFIT g SOFFIT DE ILSOFFIT DETA NO SCALE PAINT VERT CLG BLACK J.M. INT. FIN @ 12'-0" & 5/8" TYPR 4" — 20 G / STUDS @ 1E 1 /2" GYP. E SIDE OF WA IL NO SCALE D I GYPBRD. & A.C.T. DETAIL NO SCALE SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN J� 0 M. Suss ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA REFLECTIVE CEILING PLAN DETAILS ry V NUMBER OF /I w I ft I JIO'EL OLMEDO AR0015027 I I — — — — — — — — — — — — — — — — — — — — — —NAI I -4 I I PREP AREA ---- O �� -- - -- P - 2 T- 2 D W-3 C A8 A _ w VLi MEN F- B V) I_ ` 0000a0000000noo In P- 00000000� 0 oouoo I I I w T-2 00000 0 - -j Ei y 100 Z IM GEo00000000000000 o W- C 0000001oo0o000001 Q G to P-1 I AGE W_ 1 --- z � co �� - WOMEN 2 D CC P- 2 W- 4 - - -- T- 2 C A8 rq w� U _ - AA IMAGE T 1 B I C2 SIM. _ — I111610 ry co W-1At— 0 �i/� CC 3 -6" I T-1 CCENT PNL & IMAGE (o P-1 C W_1 12'-10 1 /2" ACCENT WALL PAINT B _ I J w cn Z J :D o 0 Li � zQ GC ❑ I Q W I — — Q F- U D II �� A9 I P7 C3 A10 10 -1 _ I�TCHEN J o a N F C � C4 A10 10 C2 Lu11610 w I Z T-1 0 U z d. d I - rw w< z_ —2 U N C T-1 -- --- N v C1 �� 10 ❑00 - 7'-6" W a _ o p ------- P -1 C m a, W DINING U) :: \\ P-1 \ N W- — — — — — — — — — — — — — — — — — — — — — — — -1 I — — — — — — — — — — — — — — — — — — — — — — — — — J REQUIRMENTS BY OCCUPANCY (MERCANTILE - SPRINKLED) F.B.C. 2010,TABLE 803.9: CLASS A FLAME SPREAD INDEX 0-4 SMCI<E- M LCPED INDEX 0-450 INTERIOR WALL & CEILING FINISH EXIT - A CLASS R FLAME BREAD INDEX 25-75� W)<E-MaCPED INDEX 0-450. CORRIDORS - B ROOMS AND SPACES - C CLASS G FLAME SHAD INDEX 76-2CQ 9vk)<E-DEql.CPE1D INDEX 0-45a INTERIOR WALL FINISHES & GRAPHICS PLAN 1 /411 = 1'-0" FLOOR FINISH PLAN -ALTERATION INTERIOR WALL FINISH SCHEDULES WAINSCOT TAG SURFACE SOURCE PRODUCT COLOR COMMENTS W-1WAINSCOTING (INCLUDES CAP & BASE MARLITE JM SPEC WAINSCOT SUGAR COOKIE CUSTOMER AREAS SEE PLAN W-2 WOOD WALL ACCENT PANEL CONTRACTOR 1"X6" T&G PLANKS SOUTHERN YELLOW PINE CABOT; EXTERIOR OIL BASED SEMI -TRANSPARENT, PEWTER GRAY CUSTOMER AREA, ACCENT WALL RUNS FLOOR TO CEILING, STAINED W-3 STAINLESS STEEL WAINSCOT BRUSHED S/S 20 GAUGE FROM TOP OF Q.T. BASE FULL HEIGHT TO HOOD, BEHIND GRILL AREA W-4 FRP WALL PANELING MARLITE WHITE FOOD PREP AREA EHD APPROVED SURFACES NATIONAL TAG SURFACE MFR PRODUCT COLOR COMMENTS ACCOUNT GWB PAINTED BENJAMIN MOORE # 460 HERB BOUQUET, EGGSHELL NA034 CUSTOMER AREA ABOVE WAINSCOT P-2 UPPER REST ROOM WALLS TO BE BENJAMIN MOORE # HC-34 WILMINGTON TAN, SEMI GLOSS NA034 REST ROOM WALLS ABOVE TILE PAINTED P-3 SOFFIT TO BE PAINTED BENJAMIN MOORE # HC-34 WILMINGTON TAN, SEMI -GLOSS NA034 SOFFIT AND BEHIND MENU BOARD GWP PAINTED BENJAMIN MOORE # 460 RICH CHESTNUT, EGGSHELL NA034 CUSTOMER AREA ACCENT WALL.------ T.B.D. BY CORPORATE GRAPHICS LAYOUT P-5 DOORS & DOOR TRIM TO BE PAINTED BENJAMIN MOORE # 2090-20 RICH CHESTNUT, SEMI GLOSS NA034 BATHROOM TRIM / KITCHEN DOOR/TRIM ALMOND W/ VERTICAL ACCENT STRIPES IN FIRE Q093, T-1 CERAMIC TILE DAL TILE SIZE: 6"X6" ARTISAN 0144, GALAXY (BLUE) 1469 W/ MAPEI SERIES, FOOD PREP AREA. SEE PLANS FOR AREA AND LAYOUT FRENCH VANILLA GROUT T-2 CERAMIC TILE DAL TILE SIZE: 4"X4" ALMOND W/ GALAXY (BLUE) 1469 ACCENTS BATHROOM WALL TILE, FLOOR TO 4' AFF W/ FRENCH VANILLA GROUT FLOOR FINISH SCHEDULE FLOORING TAG SOURCE TYPE DESCRIPTION COLOR COMMENTS F-1 MANNINGTON LVT NATURE'S PATH, LOCK SOLID WINDSOR OAK NATURAL CUSTOMER AREA F-2 METROPOLITAN CERAMICS 6"X6" QUARRY TILE RODUCT #108 QUARR BASICS CLEAR TONES CHESTNUT BROWN BATHROOMS, KITCHEN, BASE, COVE BASE TILE F-3 RETRO PLATE SYSTEMS POLISHED CONCRETE POLISHED CONCRETE RAW SIENNA ALTERNATE CUSTOMER AREA FLOORING NOTES: POLISHED CONCRETE FLOORS DO NOT HAVE QUARRY TILE IN FRONT OF BEVERAGE COUNTER. 1 1 /2" CONTINUE POLISHED CONCRETE FROM DINING ROOM UPTO RESTROOMS GRAPHICS PLAN LEGEND JERSEY MIKE'S FRANCHISE ITEMS TAG DESCRIPITION AA 2'X4' COMMUNITY BOARD BB WALL MURAL — 10'W x 6'H CC WALL GRAPHICS — SEPIA 2'X4, NJ-3'X5' => HANGING MENU BOARD EE SURF BOARD FF SOFFIT MURAL — VARIES WALL BLOCKING: GENERAL CONTRACTOR TO PROVIDE A MIN. OF 5/8" T&G CDX PLYWD. SHEATHING LET —INTO STUD FACE, BLOCKING FOR SHELV'G AS PER PLAN SHELF LOCATIONS OR OWNER DIRECTIONS, VERIFY INSTALLATION LOCATIONS PRIOR TO GYPBRD. INSTALLATION. FINISHED FLOOR - TI' C' BEVEL TRIM SLC MAX. FINISHED FLOOR NOTES: 1. FLOOR MATERIAL SHALL HAVE 1 /2" MAX. 2. ENTRY MATS SHALL BE RECESS MOUNTED & ANCHORED. TO BE FLUSH W/ ADJACENT FIN. FLOOR WG 475 SINGLE RABBIT CHAIR RAIL 1 - MOLDING DETAIL J OTE: VOOD SLATS TERMINATE @ THE TOP OF THE MARLITE 3ASE MOLDING. WOOD SLATS DO NOT .0 ALL THE WAY TO THE FLOOR. !TmU01wi]IOC# 2 -MOLDING DETAIL N.S. OUTSIDE FREEZER CONSTRUCTI ADHESIVE QUARRY TILE INSIDE FREEZER FREEZER WALLS FREEZER FLOOR PANEL COVE QUARRY TILE @ WALK-IN FREEZER SCALE: N.T.S. OUTSIDE COOLER ADHESIVE QUARRY TILE INSIDE COOLER COOLER WALLS COVE QUARRY TILE 0- WALK-IN COOLER SCALE: N.T.S. EXISTING GYPBD. EXISTING WALL CHAIR RAIL, PART OF 3 PART SYSTEM - 1 1 /2" MINUS 3/4" FOR PANEL TO SLIDE IN. cV WAINSCOT IN HEIGHTS OF 40" SLIDES BETWEEN CAP AND BASE BASE, PART OF 3 PART WAINSCC 5 1/2" MINUS 1/4" FOR PANEL TO SLIDE IN. (SEE W-1 ON SHEET A07) A - CHAIR RAIL DETAIL crr n I • 9" - V_n" SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN i J� M. SUBS ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA INTERIOR FINISHES GRAPHICS PLANS A7 • L OLMEDO 015027 III I i II I r I I T FINISH WALL POST -FORMED PLASTIC LAMINATE ON COUNTERTOP & SPLASH 2x8 BLOCKING BETWEEN STUDS 3/8" DIA. LAG BOLT— ® 12" 0. C. 3/4" PLYWOOD PANEL BRACE @ EACH END 3/4" PLYWOOD PANEL COVER SCREWED TO SIDE BRACES ADA TILT MIRROR BOTT. OF MIRROR 1'-10" 4" 6" 4VARld z MAX. :�i HANDICAP LAV. NO SCALE DALTILE TILE COLOR: TYPE TILE SIZE DALTILE TILE COLOR: OA ALMOND OB FIRE BRICK OC ARTISAN BROWN 0144 O GALAXY (BLUE) 1469 ------ -• 1„ ----- 3„ ------ 3„ ----- 1„ ----------- �. 4" WT - WALL TILE DETAIL FLR. FIN. - 2X6 BULL -NOSE TILE N ---- -- 1"X6" TILE LINERS ` 3"X6" STACK TILE 4"X4" FIELD TILE \t LL PII\. ELEVATION - A JERSEY MIKE'S IMAGE PAPER TOWEL DISPENSOR STORY LAVATORY- FT- < t 'E PIPES ...AT GUARD OR SKIRT SHIELD 2'-9„ MMMI -INSULATE PIPES WITH HEAT GUARD OR SKIRT SHIELD -6" x 6" "QUARRY" TILE BASE ELEVATION - B METAL DOOR JAMB PAINT -RICHI CHESTNUT FLUSH PANEL SOLID CORE WOOD BIRCH VENEER W/A CLEAR COAT FINISH u n u "QUARRY" TILE BASE ELEVATION - C SURFACES TAG SURFACE MANUFACTURER PRODUCT COLOR NATIONAL ACCOUNT COMMENTS P-2 UPPER RESTOOM WALLS BENJAMIN MOORE #: HC-34 WILMINGTON TAN, SEMI GLOSS #NA034 RESTROOM WALLS ABOVE TILE TO BE PAINTED T-2 CERAMIC TILE DAL TILE SIZE: 4"X4" ALMOND W/ GALAXY (BLUE) 1469 W/ BATHROOM WALL TILE, FLOOR TO 4' A.F.F. FRENCH VANILLA GROUT SEE PLANS FOR AREA AND LAYOUT LAVATOR INSULATE WITH HEA . OR SKIRT SHIELD- V LLf11\. VLL/'11 .. ELEVATION - A GRAB RAIL PROVIDE FLUSH CONTROL TO WIDE SIDE OF TOILET FIXTURE. x GRAB TOILE' DISPE ERSEY MIKE'S v AGE E ELEVATION - B TOILET PAPER DISPEI` JERSEY MIKE IMAGE TOILET SEAT PAPER COVE DISPENSOR X O d- WALL MOUNT ---\ TOILET GRAB BAR PAPER ROLL DISPENSOR 0 mTOILET SEAT PAPER COVER DISPENSOR I 0 i� ¢ O m d CD INFANT FOLD -OUT CHANGING TABLE ELEVATION - D 7'-4 1 /2" GYPBOARD TO GYPBOARD SOAP_ TOILET PKPENSOR A.D.A TILT r MIRROR - V-6" /� PAPER TOWEL \ DISPENSOR \ - co MEN A Lo I I 1 q 32„ D A8 B- - - - - - r \ I \ C I \ 60" J r TOWEL ISOR q MEWS TOILET -ENLARGED PLAN VIEW f-LUJfI r/'11VCL "QUARRY" TILE BASE SOLID CORE WOOD BIRCH VENEER W/A CLEAR COAT FINISH ELEVATION - C WALL MOUNT TOILET GRAB BAR TOILET PAPER ROLL DISPENSOR g WOMEN'S TOILET -ENLARGED PLAN VIEW n I JERSEY MIKE'S IMAGE 6" "QUARRY" TILE BASE WITH HEAT GUARD OR SKIRT SHIELD ELEVATION - D 8'-4 1 /2" GYPBOARD TO GYPBOARD I SCAP �-6SREN-SQR[.A TILT `� I MIRROR --� �I PA1'-6�ERRD° j 1 v1 ICD u') A \1 INFANT FdLD-OUT g I CHANGING TABLE D A8 I I - - -132" _ _ 1 1 C I \ I L--60------ WOMEN TOILET SEAT PAPER COVE DISPENSOR 5'-9" 2'-7 1 /2" GYPBOARD TO GYPBOARD GYP OARD TO GYPBO R TOWEL :NSOR SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR & MR. JOSHUA LINCOLN ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA TOILET ROOMS & INTERIOR ELEVATIONS A & B 1 1 /2" = 1'-0" MUEL OLMEDO AR0015027 BEVERAGE COUNTER ELEVATION C SCALE: 1/2" = 1'-0" ,L ROOF D CUSTOMER SERVICE COUNTER ELEVATION (CUSTOMER SIDE) SCALE. 1/2" = 1-0 6"X6" ALMOND TILE ON TILE BACKER BOARD Y2" THICK CORIAN TOP ON 1 1 /8" SUBSTRATE W/ %" EDGES - W/ %" 45 BEVELED EDGE 3Y2" POLISHED CHROME WIRE---,_ CABINET DOOR PULLS ADJUSTABLE SHELF STANDARDS WITH SHELVING MELAMINE SET TO BOTTOM OF INTERIOR SURFACE CERAMIC TILE BASE FINISHED FLOOR --- (QUARRY TILE) EXTEND UNDER BASE CABINET CORIAN BACK SPLASH E SUPPORTS FOR PEPSI DISPENSER 3/4" MARINE PLYWOOD C1 SECTION DRINK/ ICE STATION NTS ARMSTRONG SUSPENDED CEILING' T� 6"X6" DAL TILE FROM TOP OF BACK LINE COUNTER TO BOTTOM OF MENU BOARD gs, Y2" THICK CORIAN TOP ON 1 1 /8" SUBSTRATE W/ %" EDGES W/ 3/8" 45 BEVELED EDGE 3Y2" POLISHED CHROME WIRE CABINET DOOR PULLS ADJUSTABLE SHELF STANDARDS WITH SHELVING MELAMINE SET TO BOTTOM OF INTERIOR SURFACE CERAMIC TILE BASE FINISHED FLOOR (QUARRY TILE) EXTEND UNDER BASE CABINET 2'-6„ C2I SECTION (cD, DEMISING WALL NTS 3'-3" 4'-0" S-0" A.D.A I CLEAR M 1 /4" TEMPERED GLASS DIMENSIONS ARE TO CENTER I I I I LINE OF POSTS 2 -7 2 -6 L 2 -6 4 -8 VERIFY CUT DIMENSIONS WITH EQUIPMENT CUT SHEET COUNTER CONFIGURATION LIDS STRA SWEE SUGA LEM 0 ICED ICED SODA BEVERAGE COUNTER PLAN 01 4" i-I � O N I I O I /2" 10 1 / 4" COMMUNITY BOARD N.S. SCALE: 1/2" = 1'-0" 2'-10 205/256" ANGLE LINES UP W/ THE SERVICE SIDE OF THHE 3-13/128 MEATCASE SIDESPLASH ELEVATION @ MEATCASE SCALE: Y2"=1'-0" TaJ fn1VVLL VI IlIIVII LI\ 0 0 I 00 I (D UNCERSIDE OF ROOF DECK & JOIST KITCHEN END WALL INT. ELEV. E OPPOSITE SIDE BEVERAGE COUNTER 1/2" = 1'-0" Y2" CORIAN COUNTER TOP 3'-0" Y4" SUB PLY 2"X4" BRACING EITHER SIDE OF DROP -IN (MINIMUM) PREP & PAINT ALL EXPOSED WOOD 1"0 STEEL LEG FASTENED TO WITH WASHABLE ACRYLIC ENAMEL (2) 2"X4" HEADER 1 5/8"X20 GA METAL STUD @ 16" O.C. FRP PANELING " TYPE "X" GWB Y" PLYWOOD BACKING J-MOLD W. TOOLED SEALANT 0 MARLITE WAINSCOT PER FINISH PLAN 0 6" QUARRY TILE COVE BASE-----_ 6 QUARRY TILE COVE BASE W/ » RADIUS W/ %" RADIUS O SLIM FOOT QUARRY TILE COVE BASE CUT 6"X6" QUARRY TILE TO 4" TOE KICK HEIGHT SHOT PIN W/ %" WASHER @ 32" O.C. 20 GA. TRACK W/ SEALANT AND STAGGERED .145 0 X 1.25 PENETRATIC (RAMSET ICBO #1639) @ CONCRETE 1 - #8 S.D. PANHEAD TRACK TO STUD FASTENER EACH SIDE C3 SECTION @ CUSTOMER .qFR\/Ir.F (''.(M INTER NTS ED DROP —IN COLD PAN 1 "X4" HARDWOOD BLOCKING TYP. ALL AROUND 1"X6" HARDWOOD CONT. EDGE FRP PANELING 5/8" TYPE "X" GWB J—MOLD W. TOOLED SEALANT 6" QUARRY TILE COVE BASE W/ J" RADIU 6"X6" QUARRY TILE UNCERSIDE OF ROOF DECK & JOIST PAINT BLACK LL w DINING -1 42" WIDE T&G WOOD 00 PANELING WALL CD¢ I N p w J J cn z c� J Y 0 Ld z w cn O 0 0 OAK BASE PRE -FINISHED \ 2�_ 2'-9 3/4_ 7 1 /4„ SECTION E1 1/2" = 1'-0'1 UNCERSIDE OF ROOF -J DECK &JOIST PAINT BLACK T.V. L� L,_ w ¢ L- `D o I co 00 I ary 0 O CHAIR RAIL I ¢ I— z ¢ ♦— p w w J ~ � Z O O w m OAK BASE PRE -FINISHED D1 SECTION 1/2" = 1'-0" I I 1 5/8"X20 GA METAL STUD @ 16" O.C. ---- PLYWOOD BACKING MARLITE WAINSCOT PER FINISH PLAN N 3 J"X18 GA STUD CUT TO 84" I FOR DROP -IN COLD PAN RECESSION Lo 4- DRAWER DETAILS cal ATYPICAL IN CA STORES' SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN M0 � . Suss ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA INTERIOR ELEVATIONS C,D, & E MUEL OLMEDO AR0015027 -. -r-11 I. II - - - - - ---- - - - - - T - SERVICE COUNTER I NT. ELEV. (EMPLOYEE SIDE) SCALE: 1 /2" = 1'-0" STOREFR( G DINING IN 9'-0„ T-1 WALL BULKHEAD SEE FLOOR PLAN 7'-0" CLEAR A.F.F. A.C.T. ---------- A n O n O 4" A A O S L NG ■ini ■0-1 FINISH SHALL BURNISHED EMBER LAMINATE I I=KIUK WALL ELEVA I IUN UNCERSIDE OF ROOF SCALE: 1/2" = 1'-0" SERVICE COUNTER INT. ELEV. EMPLOYEE SIDE Wei S/S STAINLESS STEEL WAINSCOT 9'-9 1 /2' T-1 I— A.C.T. HOOD o UTILIT OD © CABIN 4" 0 4" 1'--6" 5'-021 1'-011 1'—.6„ 4„ O 4" O 4„ O 4„ —r — —77-1.1 . . I. r--- --�— 71iliml ��k .� P Imom 11 ■■■II rmmqm'gmmm ■ ll ■■• IIIF CAMBRO BIN STORAGE NOTE: ALL NON-STANADARD TILE SIZES TO BE CUT IN FIELD. COUNTER -r wuniv\ i iiL.L_ MILLWORK 4'-8" 5'-3" 2'-7" 12'-6" 1 /2" = 1'-0" 3'-0" 3026 DOOR ACT 10'-0" SOFFIT 9'-0„ .KNEAD 7'— 0" OAK BASE PRE —FINISHED 10'-0" A.F.F. T&G WOOD WALL SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN J� me. SUBS ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA INTERIOR ELEVATIONS FIG, & H Ain NUMBER .2•1. f/ L OLMEDO AR0015027 `qij►' � IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIINII ' � ' IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII —��— II I I 'IIII IIII! IIII IIIII IIII IIII IIII IIII I IIII IIII IIII III IIII IIII IIII IIII I �� _ ___- _ _ '� t f� I IiIIIIIIIIIIII IIIIIIII IIIIHIIIIII1IIIiII1,IlI IIIIII�;,,,; �!;, .............. ra 5��,►► �, = 9��11� II1II --- ����► � �•� 1—=L jllr �I� I ,III = -= /!�! =_==-111`,'1,,�1.��• a;moRr�I� fi�:E;?}:�3�. ° �,`°h4�'��'S>�.`V �P� 5�3�'�cig'�+,�<.e;$ . � �• � �� �;i�. • �....r • • � IIII,■I�Il�llll[4]■�•I , . •��� « — NEW FREEZER CONDENSER ROOF TOP REMOTE CAPSULE PAK � a ow ^• �����a,,����������i�i�i�i�i�i�ii� ��i":L�i�i+��i�i►i�L�i�t���r�r�►►►► �" ��� I . Ash .ii •� '� ,,• ��IR I '�I�, � �=_= IIIIIIIIIIIIIIIIU!!ull� • �=== IIIIIIIIIIIIIIIIN!!�!l � � � %r. ON1=a-a.:: 3:rk'and =arPi D�2�*g>'MI11—I`ra140 'I�� NEW RTU #1 - lox .. • ' • "av, 1I,, "1 1:., I S P �,oil NII r I �• �� �• rrrr� � • • '� �, ' 11' • • I • . as %'�IIT II � •► I.11� erg • • OEMI/�J • • C�a), MIA a� s. .. ■.�1 • • / 1OX6 SWD 10 X e AWMD E3�,�� COPE OF WORK: HVAC CONTRACTOR TO FIELD VARIFY LOCATION OF PROPOSED NEW & EXISINTG EQUIPMENT AND PLACEMENT,PRIOR TO BID & TO START OF WORK. ALL WORK IS SUBJECT TO EXISTING FIELD CONDITIONS THAT MAY ALTER THE DESIGN OF THIS PROJECT. NE WALK IN COOLER CO DENSER ROOF TOP UNIT RE OTE CAPSULE PAK VT EXHAUST FAN -1 0 CFM A PROX. LOCATION OF H AT HOOD EXHAUST —562 CFM NEW RTU #1 6 TON 40 CFM 241AY X 24 4 A PROX. LOCATION OF A SUL HOOD EXHAUST —10 0 CFM -401AY CFM 24X 24 4 APPROX. LOCATION OF AN UL HOOD FRESH —AIR SUPPLY +800 CFM -40 CFM 24 X 24 4 AY HVAC DESIGN VALUES 1 TON / 150 S.F. AREA — 1,600 S.F. 1,405 S.F./1TON PER 150 S.F. REQUIRED HVAC — 10.7 TONS PROVIDED HVAC — 12.0 TONS GENERAL HVAC NOTES ARE IN COMPLIANCE WITH 2O10 F.B.C. 1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, A MIN. OF 4 INCHES ON EACH SIDE IS SUFFICIENT. 2010 F.B.C.M. CHAPTER 13 SEC. 410.AB.3.0.3 & F.B.C.M. SEC. 603.1.3 2. ALL DUCT SYSTEMS INSTALLED IN "NON -CONDITIONED" AREAS SHALL BE CONSTRUCTED WITH APPROVED MATERIAL AND OF A VALUE OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB & MASTIC "OR" APPROVED TAPES THAT EXTEND NOT LESS THAN 1 INCH AND LABELED IN ACCORDANCE WITH THE UL-181A, PART 1 FOR DUCT BOARD OR UL 181B, PART 1 FOR FLEX. ALL CLOSURES 100% AND INSTALLATIONS SHALL BE INSTALLED AS PER 2007 F.M.C.M. CHAPTER 6, SEC. 603 ALL THRU—WALL, FLOOR & CEILING PENETRATIONS INTO THE DUCT SECTION SHALL CONTAIN A BRANCH DUCT FABRICATED OF RIGID FIBROUS GLASS DUCT BOARD OR RIGID METAL AND IS SEALED TO BOTH DUCT SECTION AND GRILLE SIDE WALL SURFACE. THE BRANCH DUCT SHALL BE FABED. AND ATTACHED IN ACCORDANCE WITH M603.3 OR M603.4.2 RESPECTIVE TO THE DUCT TAPE USED. " DRAFT 2007 F.S.R.S. MECHANICAL VOLUME". 3. ALL DUCT TRUNK 90 DEGREE TURNS OR TEES, SHALL HAVE TURNING VANES. 3 PIECE OR 45 DEGREE TURNS CAN BE USED IN PLACE OF 90 DEGREE TURNS AND DO NOT NEED TURNING VANES. 4. ALL REGISTERS, GRILLES & DIFFUSERS MUST BE TESTED IN ACCORDANCE WITH ASTM E 84, AND VOLUME DAMPERS OR OTHER MEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN DUCTS OR AT EACH INDIVIDUAL REGISTER, GRILLE OR DIFFUSER. 5. AIR DISTRIBUTION SYSTEMS SHALL BE TESTED, ADJUSTED, AND BALANCED BY A LICENSED ENGINEER OF THIS STATE OR A CURRENT CERTIFIED ORGANIZATION. EXCEPTION: 1) BUILDINGS WITH CAPACITIES OF 15 TONS OR LESS "PER SYSTEM" MAY BE TESTED AND BALANCED BY THE LICENSED MECH. CONTRACTOR. EXCEPTION: 2) BUILDINGS WITH CAPACITIES OF 65,000 BTU/H OR LESS "PER SYSTEM" ARE "EXEMPT". F.B.C. 2007 CHAPTER 13, SEC. 410.1.ABC.4.1 DOCUMENTS SHALL REQUIRE THAT ALL HVAC SYSTEMS BE BALANCED SERVING ZONES EXCEEDING 5000 SQ.FT. F.B.C. 2007 CHAP. 13, SEC. 410.AB.4.1 6. AIR HANDLERS (OVER 2000 CFM) SHALL HAVE A SMOKE DETECTOR INSTALLED IN THE SUPPLY. F.B.C.M. 2007 CHAPTER 6, SEC. 606.2.1. WHEN TWO AIR HANDLERS SHARE A COMMON SUPPLY OR RETURN "AIR DUCT" OR "PLEMUN" AND THE TOTAL CFM'S ARE GREATER THAN 2000, A SMOKE DETECTOR SHALL BE INSTALLED IN THE SUPPLY AND RETURN AS PER F.B.C.M. 2007 SEC. 606.2.3 AND BE IN ACCORDANCE WITH NFPA 72 SMOKE DETECTOR TEST STATIONS SHALL HAVE A TROUBLE INDICATOR LIGHT, INUNDATING ANY AIR DUCT TROUBLE. NFPA 90A 2002, CHAPTER 6 NOTE: A "PLEMUN" CAN NOT BE USED AS AN OCCUPANCY SPACE OR STORAGE AREAS. AS PER. NFPA-90A, SEC. 4.3.10.1.1 7. FIRE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND CEILING DAMPERS LOCATED WITHIN AIR DUCTS MUST BE INSTALLED BY MANUFACTURERS SPECS. AND BE TESTED IN ACCORDANCE WITH UL 555, AND THE F.B.C.M. 2007 CHAPTER 6, SEC. 607 ALL DAMPERS LOCATED AT CEILING OR WALL PENETRATIONS MUST HAVE ACCESS DOORS TO RESET DAMPER. UNLESS THE DAMPER IS IN THE DIFFUSER THAN IT CAN BE RESET THRU THE DIFFUSER. SMOKE DAMPERS IN A DUCT MUST HAVE A DETECTOR WITHIN 5 FT. OF THE DAMPER WITH NO AIR INLETS OR OUTLETS BETWEEN THEM. FOR FIRE AND SMOKE DAMPER ACTUATION METHODS REFER TO F.B.C.M. 2007 CHAPTER 6, SEC. 607.3.1.1 AND 607.3.2.1 8. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO F.B.C.M. 2004 CHAPTER 6, SEC. 603.10 9. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT OUTLET, OR SANITARY SEWER VENT OUTLET. 10. ALL EXHAUST DUCTS, SHALL BE CONSTRUCTED OF GALV. METAL F.B.C.M. 2007 CHAPTER 5, SEC. 501.4 11. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE MECHANICALLY VENTILATED. "EXCEPTION" RESIDENTIAL BATHROOMS HAVING NO LEES THAN 4 PERCENT OF FLOOR SPACE. F.B.C.M. 2007 CHAPTER 4, SEC. 402.3 12. ALL EXHAUSTED BATHROOMS, CLOSETS & STORAGE ROOMS SHALL HAVE UNDER CUT DOORS OR A METHOD FOR MAKE UP AIR TO BE RETURNED EQUAL TO THE AMOUNT OF CFM'S EXHAUSTED. F.B.C.M. 2007 CHAPTER 6, SEC. 601.4 13. CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO A STREET, ALLEY OR OTHER AREA AS TO CAUSE A NUISANCE. MUST TERMINATE A MIN. OF 18" FROM EXT. WALL. PER AUTHORITY OVER JURISDICTION CONDENSATE DRAIN MAY DRAIN TO A STORM SYSTEM, UTILITY SINK, OR SEWER BY APPROVED MEANS. CONDENSATE DRAIN LINE SHALL NOT BE LESS THAN 3/4 INCH DIAMETER AND SHALL NOT DECREASE IN SIZE. 2007 F.B.C.M. CHAPTER 3, SEC. 307.2.2 ALL HORIZONTAL PRIMARY DRAIN LINE WITHIN UNCONDITIONAL AREA SHALL BE INSULATED. AS PER F.B.C.M. 2007 CHAPTER 3, SEC. 307.2.5 AUXILIARY DRAIN PAN OR SECONDARY DRAIN LINE MAY BE REQUIRED WHERE DAMAGE TO ANY BUILDING MAY RESULT FROM OVERFLOW OR ANY STOPPAGE, AUXILIARY DRAIN PAN MUST HAVE A MIN. DEPTH OF 1.5 INCHES AND BE A MIN. 3 INCHES LARGER THAN UNIT OR COIL AND HAVE SEPARATE DRAIN LINE AN AUXILIARY PAN WITHOUT SEPARATE DRAIN LINE SHALL BE EQUIPPED WITH WATER LEVEL DETECTION DEVICE FOR SHUT OFF PRIOR TO OVERFLOW METALLIC PAN MUST HAVE A MIN. THICKNESS 0.0276-INCH, NONMETALLIC 0.0625-INCHES. AS PER F.B.C.M. 2007 CHAPTER 3, SEC. 307.2.3 ALTERNATIVE TO SEPARATE DRAIN LINE: A WATER LEVEL DETECTION DEVICE THAT WILL SHUT EQUIPMENT PRIOR TO OVERFLOW OF PAN. WATER LEVEL DETECTION DEVICE SHALL CONNECT TO DRAIN PAN AT A HIGHER LEVEL THAN THE PRIMARY DRAIN CONNECTION. CONDENSATE DRAIN LINE CAN BE STRAPPED WITH 2" NYLON STRAP AND SUPPORTED EVERY 10' VERTICAL AND 3' HORIZONTAL 14. REFRIGERANT PIPING FOR REFRIGERANT LINES SHALL BE INSULATED TO A THERMAL RESISTIVELY OF AT LEAST R=4HR. SUCTION LINE MUST BE INSULATED IN ACCORDANCE WITH ASTM E96. AS PER THE F.B.C.R. 2007 CHAPTER 14, SEC. M1411.4 15. IF HVAC EQUIPMENT OTHER THAN SPECIFIED BY DESIGNER IS SUBSTITUTED, IT'S CAPABILITIES OF SENSIBLE HEAT REMOVAL MUST BE EQUAL TO THE EQUIPMENT SPECIFIED BY THE HVAC DESIGNER. THE HVAC DESIGNER WILL NOT BE RESPONSIBLE FOR ANY SYSTEM NOT INSTALLED ACCORDING TO PLANS. NOT TO SCALE IE�O 5 p 5CON�EGf �oOD F Ea Svl 0 pIR ou1yJoE t✓�f Ou Lj PTE I� �O� O V 0 R AIR R RooF �U 1CON� oo f 0 �� K V v ����� �� D��.RN AIR Rg 5 ����r� SEE GENERAL HVAC NOTES #6 SMOKE DETECTOR FOR A/H'S OVER 2000 CFM AS PER F.B.C.M. SEC. 606 & NFPA 90—A ROOFTOP PACKAGED HVAC UNIT DOWNFLOW DETAIL RM CLIP 1" X 1-1/4" 14 GAUGE METAL 1" 03 3/4" 4 @ ° 3/16" 1-1/4" 3/8" 5/8" r14 GAUGE METAL ETAL DIA. "NOTE: 4 CLIPS PER UNIT". 2 EACH 3/16" X 3/8" SHEET METAL SCREWS IN THE SLOTTED HOLES THRU RM CLIP IN UNIT 2 EACH 3/16" X 3/8" SHEET METAL SCREWS IN THE SLOTTED HOLES THRU RM CLIP IN CURB FAN SCHEDULE FAN# MFG. TYPE CFM VOLTS PART# DUCT DIA. 1 BROAN CEILING EXH. FAN 50. 120 688 5 INCHES 2 BROAN CEILING EXH. FAN 50 120 688 5 INCHES NOTE: ELECTRIC REQUIREMENT FOR EQUIPMENT TO BE H . V. A. C. EQUIPMENT SCHEDULE FIELD VERIFIED BY ELECTICTIAN/MECHANICAL CONTRACTOR. A/C MFG. MODEL NO. SENSIBLE LATENT TOTAL-BTUH COOLING/HEATING EE�R SEER VOLTAGE RLA. M.C.A. BREAKER CFM / CFM 1 CARRIER RTU 50TM-007-501 53,300 6 TONS 74,800 15 KW 90,000 11.3 3/60 208/230 38.1 40 40 2400 2 CARRIER RTU 50TM-007-501 53,300 6 TONS 74,800 15 KW 90,000 11 3 3/60 208/230 38.1 40 40 2400 ALL REGISTERS, GRILLS & DIFFUSERS BOTH SUPPLY & RETURN SHALL HAVE A FLAME SPREAD RATING NOT OVER 25 WITHOUT EVIDENCE OF CONTINUED PROGRESSIVE COMBUSTION AND A SMOKE DEVELOPED RATING NOT OVER 50 WHEN TESTED IN ACCORDENCE WITH ASTM 84 (UL 723) U.L. 181 EROSION AND IMPACT TEST W/-R"—VALUES OF 4.2 AND 6. AS PER F.B.C.M. CHAPTER 3, SEC. 603.15 E I TURNING VANES SUPPORTS 5 ft. MAX. DISTANCE TYPICAL SPIN -IN FITTING / OR TAP COLLAR APPROVED HANGER WIRE MIN. R-6, 1 1/2" FIBERGLASS DUCT DRAW BAND FOR INTERIOR LINER � > OR FLEX IN ATTIC OR UNCOND. SPACE APPROVED HANGER WIRE MIN. R-6, 1 1/2" INSULATED FLEX SUPPORTS 6 ft. MAX. DISTANCE IN ATTIC OR UNCOND. SPACE HANGER CHANNELL 1.5 INCH WIDE (min.) tZy 1 TYPICAL DUCT TRUNK SUPPORT DETAIL SEE GENERAL HVAC NOTE # 2 DUCT TRUNK FOR 100% CLOSURES AND INSTALLATIONS / EXTERIOR LINER SEAL SHALL FASTEN TO DUCT TRUNK AS PER 2004 FLORIDA MECHANICAL CODE SECTION 603 DUCT SUPPORT INTREVALS HORIZONTAL DUCT — 5FT. VERTICAL DUCT — 6FT. TYPICAL DIFFUSER IN NO CASE MATERIAL SUPPORTING FLEX DUCT THAT IS IN DIRECT CONTACT WITH IT MUST BE LESS THAN 1 J" INCHS WIDE NONMETALLIC DUCTS ALL DUCT SHALL BE TESTED IN ACCORDANCE WITH UL 181 ALL DUCT SHALL BE LISTED AND LABELED AS CLASS 0 OR CLASS 1 ALL DUCT SHALL BE A MIN OF R-6 INSULATION IN UNCONDITION AREAS RTU FRESH AIR INTAKE OUTSIDE AIR AS PER ASHRAE 62.1 OUTDOOR AIR CALCULATIONS 62-1999ASHRAE AREA DESIGNATION FLOOR AREA PERSONS / 1000 FT2 TOTAL PERSONS CFM / PERSONS CFM / FT2 CFM REQUIRED CFM PROVIDED SYSTEM DESIGNATION FOOD PREP. 354 20 2 15 - - - - 75 1000 KITCHEN 252 20 3 - - - - 75 1200 COORIDOR 36 - - - - ---- ---- .05 30 200 DINING 670 ---- 43 20 ---- 860 2800 RESTROOMS 62 ---- - - - - 50/WC x 1 _--- 100 100 ®'SUPPLY DIFFUSERS —RETURN AIR DIFFUSER Qr — T—STAT. Nil —DUCT SMOKE DETECTOR TEST STATION 0 — DUCT SMOKE DETECTOR F/D —F/D DAMPER IN DUCT [;�]—BALANCING DAMPER IN SUPPLY —BALANCE DAMPER O/A ®SUPPLY & RETURN DIFFUSER ® WITH FIRE/SMOKE DAMPER RETURN TRUNK 940 5300 RTU-1 = 4000 RTU-2 = 3000 EXHAUST AIR/FRESH AIR INTAKE CFM'S BATHROOMS 50 CFM PER WATER CLOSET —100 4824 ND-2—PSP—F HOOD EXHAUST —1000 VHB VHB HOOD EXHAUST —562 TOTAL EXH. —1,700 EXHAUST HOOD MAKE UP +800 MAKE UP FROM UNITS +970 TOTAL MAKE UP +1770 BUILDING AIR BALANCE +70 OUTSIDE AIR SCHEDULE SPACE OCCUPANTS CFM'S BATHROOMS 50 CFM PER WATER CLOSET -100 4824 ND-2-PSP-F HOOD EXHAUST -1000 4824 VH B HOOD EXHAUST -562 TOTAL —1,662 CEILING EXHAUST FAN DETAIL N T S ROOF CURB FLAT ROOF CAP CEILING/ROOF ROOF FLASHING EXH. DUCT FRAMING EXHAUST FAN EXHAUST DUCT P�� CEILING CEILING �� GRILLE TEST BALANCE: ALL DRAWINGS SHALL BE REVIEWED PRIOR TO WORK. VERIFY TEST AND BALANCE OF HVAC EQUIPMENT AND EXHAUST AND SUPPLY HOODS CFMS AS REQUIRED TO ACHIEVE PROPER COOLING & VENTILATIONS. ANY DESREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN PROFESSIONAL. FIELD CHANGES: HVAC SYSTEM FIELD CHANGES SHALL BE DOCUMENTED IN FORM OF AS—BUILTS, VALUE ENGINEERED DRAWINGS, OR PRODUCT SPECIFICATIONS, AND SUBMITTED FOR APPROVAL. SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR 8c MR. JOSHUA LINCOLN J� 0 M. SUBS ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA HVAC PLAN 11 NUMBER HVAC PLAN LEASABLE GROSS AREA - 1,600 S.F 1/4" = 1'-0" - �1UEL OLMEDO AR0015027 CANOPY GRIDDLE HOOD (RIGHT UTILITY CABINET) MAX. LI IVT`JJ I RISERS v J� RISERIS v HOOD MODEL LENGTH COOKING TOTAL TOTAL CONSTRUCTION TEMP. EXH. CFM WIDTH LENG. DIA. CFM S.P. SUP. CFM WIDTH LENG. DIA. CFM S.P. 4824 5' 0.00" loll 9" 1000 -0.319" 10" 24" 800 0.268" 430 SS 600 Deg. 1000 800 ND-2-PSP-F Exposed Where Ex p GREASE FILTERS LIGHTS FIRE SYSTEM ELECTRICAL SWITCHES FIRE HOOD TYPE QTY. HEIGHT LENGTH QTY. TYPE WIRE GUARD LOCATION SYSTEM PIPING HANGING WGHT TYPE SIZE MODEL # QUANTITY LOCATION 3 16" 20" 1 Light SS Baffle with Handles 2 Incandescent Light Fixt NO Right Ansul R102 1.5 SC-111110FP Outside YES 411 LBS 1 Fan FIELD WRAPPER 18.00" High Front, Left, Right BACKSPLASH 120.00" High X 108.00" Long 430 SS BREAD OVEN HOOD (BACK WALL) MODEL LENGTH X. COKING TEMP. AU HOOD CONSTRUCTION CONS HANGING WGHT TOTAL EXH. CFM RISER S WIDTH LENG. DIA. CFM S.P. 5424 VHB 3' 9.00" 700 Deg. 562 9" 10" 562 -0.075" 430 SS 100% 182 LBS OPTIONS FIELD WRAPPER 12.00" High Front, Left, Right BACKSPLASH 84.00" High X 45.00" Long 430 SS FIRE SYSTEM/INSTALLATION DETAILS Stainless Steel BacksDlash and Sidesplash Backsplash is to be manufactured from #3 or #4 finish S/S of the some guage and material as the hoods. It will be supplied with Batton strips and end strips as needed to close all seams and edges. Li - 3 /8'� Batton Strip Detail APPLIANCE PROTECTION NOZZLE PRE -WIRED ELECTRICAL TERMINAL BOX WITH TERMINAL STRIPS AND SINGLE PHASE CONTACTORS PLENUM PROTECTION NOZZLE FAN AND LIGHT CONTROL PANEL 0 DUCT PROTECTION NOZZLE r-DETECTORS TYPICAL ANSUL R-102 SYSTEM LAYOUT NOTE: REMAINDER OF AIR TO BE MADE UP BY A/C SYSTEM HOOD SHALL BE TEST AND BALANCED BY A CERTIFIED COMPANY AND A REPORT WILL BE TURNED IN PRIOR TO FINAL INSPECTION 2" FLANGE TO FASTEN TO WALL WRAPPER END FIELD DRILLED HOLE FIELD WRAPPER WIRE PULL IN CONDUIT BY ANSUL CONTRACTOR REMOTE MANUAL PULL STATION I REMOVABLE STAINLESS STEEL SERVICE DOOR AGENT TANK OEM RELEASE/ BRACKET ASSEMBLY GV GAS LINE MECHANICAL GAS SHUT OFF VALVE PROVIDED BY CAPTIVEAIRE, INSTALLED BY PLUMBING CONTRACTOR WRAPPER PANELS FLANGED FOR RIGIDITY WRAPPER END FACTORY WELDED MOUNTING CHANNEL SPECIAL 1/8" KINK '—� -WRAPPER FRONT STAINLESS POP —RIVETS BY OTHERS DETAIL VERIFY GAS VALVE SIZE TYPICAL ANSUL R-102 SYSTEM LAYOUT JOB Jersey Mike's PROTO 9-D LOCATION ANSUL (RIGHT CABINET MOUNT) 0e, _= DATE 2012 JOB , • r' -= - _ DWG # DRAWN BY RM-32 REV. SCALE Not To Scale JOB NO MODEL NUMBER DRAWN BY 5CHEMATICTYPE SC-111110FP INSTALL JOB NAME DATE DWG NO Jersey Mike's — PROTO 2013 ECP #1-1 DESCRIPTION OF OPERATION: 120V 1 Phase w/ 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fan(s) On/Off Thermostatically Controlled. Room 1 emperature sensor shipped loose for field installation. 2 1 HOOD LIGHTS 1 BREAKER PANEL TO HOOD CONTROL PANEL I HOOD PANEL B1 BLACK Responsibility: Electrician TO - �� W1 WHITE - ------ - 3 HOOD LIGHTS- ------- ---- GREEN - - - BREAKER PANEL HOOD PANEL 1400 W MAX WIRE TO J BOX ON TOP OF HOOD 4 BREAKER 1PH - - ---Hot- -- - 120 V -- Neutral__ �� HOOD PANEL �� ALL SWITCHES FACTORY WIRED 4I 15 A - Ground _ �N�J �J TO J4 �___ , CAT-5 CONNECTION 5 - - - CONTROL- POWER. DO NOT WIRE SWITCHES I TO SHUNT TRIP BREAKER. BREAKER 1PH ---- -- ----------- ----Hot- H2 J 6 120 V ------ ---- ---Neutral HOOD PANEL T1 A� \I - L� -I 15 A HOOD LIGHT SWITCH #1 -- INPUT POWER TO T1 B�'� - WIRE TO CONTROL BOARD. ROOM TEMP KITCHEN TEMP SENSOR MOUNTED IN ROOM AWAY 7 BREAKER 1PH - - - --------- ---- --Hot-- - - L1 L SENSOR FROM HEAT SOURCES. SEE MANUAL 115 V --- -- ---- - --- -- --Neutral-- 15 AMP EXH-1 HOOD PANEL T2A(')- - TO _ 1 _T2B FACTORY WIRED TEMPERATURE HOOD 1 BREAKER 1PH ---- - ----- Hot DUCT SENSOR SENSOR. MOUNTED IN EXHAUST DUCT RISER 1 9 115 V -- -- - - ---- ---- - Neutral_ - t 15 AMP SUP-3 THE FOLLOWING CONNECTIONS - MAY OR MAY NOT BE 10 REQUIRED BASED ON JOBSITE SPECIFICATIONS SHUNT COIL 11 HOOD PANEL -) S_T : HOT TO SHUNT COIL --- - ----- -- ---- �h� J HOOD CONTROL PANEL TO FANS / MUA SIGNAL FOR ' -_N-_1 NEUTRAL FROM SHUNT COIL - - -- - - -- - EXTERNAL ST TERMINAL IS ENERGIZED Responsibility: Electrician 12 SHUNT TRIP IN FIRE CONDITION. HOOD PANEL FANS 13 FAN: 01 EXH-1 HOOD PANEL �� � — COMMON - --- - - ----- — - LEG_ 1 L HOT - - - Load Wiring T1 ( - _ -__ _ ---- - _ ___ _ -o--0 SPARE FIRE �AR2�,� NORMALLY CLOSED -- C-1 T2 �� LEG=� / NEUTRAL /� SYSTEM DRY `TR2, CRouN� ---- - -- -- WIRE DIRECT �N -- CONTACT SPARE CONTACTS USEDRWHENL FIREPEN ISYSTEM DISCHARGES TO DISABLE 14 TO STARTER WIRE TO EQUIPMENT OR PROVIDE SIGNALS. (NOT FOR BUILDING FIRE ALARM) DISCONNECT 15 FAN: 03 LEG 1 1 HOT__--� BLACK _: Load Wiring �T1 - - - - SUP-3 o C— 2 .LEG_ 2 L NEUTRAL- - - _�__- WHITE_- 16 j GROUND_ _ _ _ ® _ GREEN �71v �I WIRE DIRECT WIRE TO FACTORY TO STARTER PROVIDED CONDUIT DROP 17 I I I 18 H OOD CONTROL PANEL TO ACCESSORY ITEMS 19 Responsibility: Electrician HOOD PANEL COMPONENT 20 MICROSWITCH 1 HOOD PANEL � C1 C j----------- ---- -- ---- --C'�'DNCI TO --- --- - I 21 JARI WIRE C TO COMMON. FIRE SYSTEM : WIRE AR1 TO NORMALLY CLOSED. MICROSWITCH C1 TO AR1 SHOULD HAVE I MICROSWITCH 1 22 CONTINUITY WHEN ARMED. }- IF MORE THAN 1 ONE FIRE SYSTEM MICROSWITCH 2 23 WIRE IN SERIES C_ NC AS SHOWN HERE 24 25 ETL LISTING DESCRIPTION BLOCKI THE CAPTIVE AIRE MODEL ND-2 HAS BEEN U.L. 710 TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 200 CFM PER LINEAR FOOT OVER 600 DEGREE COOKING EQUIPMENT 1/2" CIA. ALL THREAD ROD CONNECTED TO RCOF JG i-iRGUGH ANOTHER HAW ANGLE 1/2" DIA. HcAVY DUTY NUT WF -ROVE AND OW BELOW ANGLE *ROU AND NU-S TO BF SUPPLIED BY INJTAU_!NG CCNTRACTOR HANGING ANGLE IS PRE-F'JNC F+ED A' FAC R)RY SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR 8c MR. JOSHUA LINCOLN J� M0 t� . ENDS ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA HOOD SCHEDULES NUMBER SAMUEL OLMEDO AR0015027 1111 11 11 1 1 9 - i I--------- T-- NON TEMPERED SUPPLY FAN (DOWN DISCHARGE) MUA FAN INFORMATION FAN UNIT MODEL # CFM ESP. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) SONES A1—G10D 726/800 0.500 800 1.000 1 115 10.2 212.56 15.5 VERIFY ECM Wiring Package — Manual Speed Control. CURB ASSEMBLIES ON WEIGHT ITEM SIZE FAN A1—G10D 1 29 LBS Curb 21.000"W x 21.000"L x 20.000"H *NOTE: Verify CFM with Hood Drawing A1-G10D - SUPPLY FAN 1. DIRECT DRIVE DIRECT DRIVE UNTEMPERED SUPPLY UNIT 10" BLOWER IN SIZE #1 HOUSING WITH SPEED CONTROL, DISCONNECT SWITCH. 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. ECM WIRING PACKAGE AND MANUAL CONTROL FOR ECM MOTORS ON PRVS. GRIDDLE FAN (CANOPY HOOD) EXHAUST FAN INFORMATION FAN UNIT MODEL # MODEL CFM ESP. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) SONES DU50HFA DU50HFA 1000 1.000 1359 0.500 1 115 8.1 64.81 12.9 FAN OPTIONS 1 — Grease Box CURB ASSEMBLIES ON FAN WEIGHT ITEM SIZE DU50HFA 31 LBS Curb 19.500"W x 19.500"L x 20.000"H Vented Hinged BREAD OVEN FAN FXHAU�T FAN INFORMATION FAN UNIT MODEL # CFM ESP. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) SONES DU33HFA 562 0.750 1361 0.333 1 115 4.1 52.56 8.4 FAN OPTIONS 1 — Gravity Back Draft Damper CURB ASSEMBLIES ON FAN WEIGHT ITEM SIZE DU33HFA 30 LBS Curb 19.500"W x 19.500"L x 22.000"H FEATURES: ROOF MOUNTED FANS RESTAURANT MODEL UL705 AND UL762 VARIABLE SPEED CONTROL INTERNAL WIRING WEATHERPROOF DISCONNECT THERMAL OVERLOAD PROTECTION (SINGLE PHASE) HIGH HEAT OPERATION 300°F (149°C) GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE—UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS GREASE BOX 1 3/4" 27 13 1 /4" 3 7/8" 29 3/4" 25 BLOWER DISCHARGE 11 1 /2" 32 1 /8" AIRFLOW f— SERVICE DISCONNECT SWITCH BLOWER/MOTOR ACCESS DOOR 24" SERVICE �21 FAN #1 DU50HFA — EXHAUST FAN DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FAN #2 DU33HFA — EXHAUST FAN 17 1/2 21 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) /2 /2 /2 30 1 /4 2 LIFTING LUG 3 3/41' 16 1 /4" 20" EQUIPMENT CURB �21 ROOF OPENING 2" SMALLER THEN CURB DIMENSION. 14101111:1:: '0 GAUGE TEEL ;ONSTRUCTION NGE / ROOF OPENING DIMENSIONS 17 1/12 17 1/2 2 FA C1m7 '0 GAUGE �TEEL :ONSTRUCTION I „N G E / ROOF OPENING DIMENSIONS 171 /2 17 1 /2 SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT, THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR & MR. JOSHUA LINCOLN ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA FAN SCHEDULES M3 EET NUMBER u r SAMUEL OLMEDO AR0015027 ETL LISTING DESCRIPTION BLOCK THE CAPTIVE AIRE MODEL VHB HAS BEEN U.L. 710 TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 100 CFM PER LINEAR FOOT OVER 700 DEGREE COOKING EQUIPMENT V-10 1/2" V-10 1/2' 3'-9" OD PLAN VIEW - BREAD OVEN HOOD 3' 9.00" LONG 5424VHB ETL LISTING DESCRIPTION BI THE CAPTIVE AIRE MODEL ND-2 HAS BEEN U.L. 710 TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 200 CFM PER LINEAR FOOT OVER 600 DEGREE COOKING EQUIPMENT v c) 0 6" GRIDDLE COOKING SURFACE 6" OD tility Cabinet U.L. Listed Incandescent Light Fixture -High Tamp Assembly „ o -�24"-* Q 0 30" 30" 36" 36" 5' 0.00" D 12" PLAN VIEW - GRIDDLE HOOD 50.00" LONG 4824ND-2-PSP-F 1/2" DIA. ALL THREAD ROD 1/2" DIA. HEAVY DUTY NUT CONNECTED TO ROOF JOIST ONE ABOVE AND ONE BELOW THROUGH ANOTHER HANGING HANGING ANGLE ANGLE " ROD AND NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY ND-2 HANGING ANGLE DETAIL DUCT LAYOUT VHB MODEL MAKE-UP AIR HOOD & FANS ( U.L. LISTED / NSF APPROVED ) 10'-0 MIN -40 FROM EXISTING ADJACENT TENANT HOODS EXHAUST FAN GREASE SERVICE I COLLECTOR DISCONNECT I I U.L. LISTED 705 � z J � CD 3M F.R. I z DUCT WRAP TAPE I � I 00 16 Go ROOF CURB I I I I I I I STRUCTURE I 1 PROVIDE 3M F.R. I 1 DUCT WRAP TAPE (OR EQUAL APPL.) FOR ANSUL HOOD I 8" X 10" EXHAUST AND SUPPLY DUCTS I I FIELD WRAPPER THAT ARE W/IN 6" I I 18.00" HIGH OF COMBUSTIBLE I 1 (SEE HOOD MATERIAL/SURFACE. I OPTIONS TABLE) EXHAUST DUCT HANGING ANGLE 0z EXHAUST RISER of NOTE: C14 FIELD VARIFY DRAIN ALL HEAD FULL PERIMETER CLEARANCES GUTTER 1 IP17� 6" 6" PRIOR TO PURCHASING OF MIN. 4,-6„ MIN. HOOD EQUIPMENT. BREAD OVEN h K10 a 0 I i� S.S. BACKSPLASH SECTION VIEW - MODEL 5424VHB GENERAL NOTES : 1. VERIFY ROOF CONDITIONS PRIOR TO WORK. 2. ALL PENETRATIONS SHALL BE COORDINATED WITH ROOF MFR. SPEC. & WARRANTY REQUIREMENTS. 3. ALL NEW ROOF LOADED EQUIPMENT SHALL BE VERIFIED BY A STRUCTURAL ENGINEER FOR LOADING REQUIREMENTS. 4. ALL EXHAUST AND SUPPLY ROOF VENTS SHALL BE LOCATED TO MEET ALL CLEARANCE REQUIREMENTS BY CODE AND MANUFACTURER REQUIREMENTS PRIOR TO INSTALLATION 5. ALL PHASES OF INSTALLATION SHALL COMPLY WITH 2O04 VERSION OF NFPA 96. 6. EXHAUST DUCT TO BE PROTECTED FROM COMBUSTIBLES PER NFPA96 AND LOCAL CODE. 7. WRITTEN MEASUREMENTS HAVE PRECEDENCE OVER SCALE. 8. PROVIDE CLEANOUTS IN EXHAUST AIR DUCTS AS INDICATED TO ALLOW CLEANING AT ALL BENDS AND HORIZONTAL RUNS. 9. EXHAUST DUCT TO BE 16 GA. GALVANIZED STEEL ALL SEAMS AND JOINTS TO HAVE A LIQUID TIGHT CONTINUOUS EXTERNAL WELD. 10. FAN TO HAVE A MINIMUM OF 10 FT. OF CLEARANCE FROM THE OUTLET TO ADJACENT BUILDINGS, PROPERTY LINES, AIR INTAKES OR 3 FT. VERTICAL CLEARANCE PER NFPA96 11. HORIZONTAL EXHAUST DUCT TO SLOPE BACK TO HOOD,MINIMUM OF .25" PER FOOT 12. HOOD TO OVERHANG COOKING EQUIPMENT 6" ON ALL OPEN SIDES. 13. BUILDING PRESSURE SHALL NOT EXCEED 0.02" WATER COLUMN AT EXTERIOR DOORS. 14. KITCHEN SHALL BE BALANCED TO BE NEGATIVE WITH RESPECT TO THE DINING ROOM. 15. ANY DUCTWORK WITHIN 18" OF COMBUSTIBLES TO BE WRAPPED WITH FIREMASTER FASTWRAP XL+ DUCT LAYOUT ND-PSP MODEL MAKE-UP AIR HOOD & FANS 10'-0 MIN FROM EXISTING ADJACENT TENANT HOODS EXHAUST FAN T--�- ---T 1 I � I i GREASE I I z COLLECTOR I rl CD I I z I I I I I 00 3M F.R. DUCT WRAP TAPE EXHAUST DUCT 16 Go GALVINIZED LIQUID TIGHT WELDED HANGING ANGLE U.L. CLASSIFIED BAFFLE -TYPE GREASE FILTERS 3" INTERNAL STANDOFF SLOPED GREASE DRAIN - WITH REMOVABLE CUP S.S. BACKSPLASH 10'-0" MIN. ° SERVICE DISCONNECT U.L. LISTED GREASE FAN 705\762 � r 1 1 16 Go ROOF -� 1 1 1 CURB 1 1 I I I I I I I �I I 1 I I I I I I I I I I 1 � I 1 I I 1 I r------------� I I I I v O 14" o 1 cV 3'-9„ 4'-0" HOOD SHALL OVERHANG COOKING SURFACE BY 6" MIN. ON ALL OPEN SIDES. d 00 I GRILLE K22 16. HOOD IS EQUIPTED WITH TEMPERATURE SENSOR DEVICE THAT WILL ACTIVATE FANS WITH HEAT TEMPERATURES 85 DEGREES OR HIGHER. 17. INCLUDES: FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS BY CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE VISITS ONLY (ONE VISIT TO SET PULL STATION & SYSTEM HOOKUP AND ONE VISIT FOR ONE TEST; ADDITIONAL VISITS WILL RESULT IN ADDITIONAL CHARGES), ONE MECHANICAL GAS VALVE PER SYSTEM AT A MAXIMUM SIZE OF 2", PERMIT, AND SYSTEM TEST. EXCLUDES: UNION LABOR & PREVAILING WAGE (LABOR & WAGES WILL BE ADDED IF APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND CONNECTIONS, HANGING OF FIRE CABINET, SHUNT TRIP, HANDHELD EXTINGUISHER(S), ON -SITE RE -PIPING DUE TO EQUIPMENT LAYOUT CHANGES. 18. THE RESTAURANT FIRE SUPPRESSION SYSTEM SHALL BE THE PRE-ENGINEERED TYPE WITH A FIXED NOZZLE AGENT DISTRIBUTION NETWORK. IT SHALL BE LISTED WITH UNDERWRITERS LABORATORIES, INC. (UL) 19. THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATION WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT-OFF APPLICATIONS. 20. THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM ACETATE -BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT OF GREASE RELATED FIRES. IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTIONS FOR LIQUID AGENT HANDLING AND USAGE. 21. THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM, THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ LINKAGE ASSEMBLY. 22. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHT SWITCH IN KITCHEN AREA. 23. FIRE MODE REQUIRES EXHAUST FANS TO OPERATE CONTINUALLY AND SUPPLY FANS TO STOP. 24. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE EXTINGUISHING SYSTEM IS ACTIVATED. 25. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEMS. SECTION VIEW - MODEL 4824ND-2-PSP-F - INTAKE L PROVIDE 3M F.R. DUCT WRAP TAPE (OR EQUAL APPL.) FOR ANSUL HOOD EXHAUST AND SUPPLY DUCTS THAT ARE W/IN 6" OF COMBUSTIBLE MATERIAL/SURFACE. - SUPPLY AIR DUCT SNAPLOC - SUPPLY RISER W/ VOLUME DAMPER - 23.5% OPEN STAINLESS STEEL PERFORATED PANEL N OTE: FIELD VARIFY ALL HEAD CLEARANCES PRIOR TO PURCHASING OF HOOD EQUIPMENT. STRUCTURE - X HAUST DUCT M O z I EXHAUST FAN U.L. LISTED GREASE FAN 705\762 GREASE COLLECTOR # 10 TEX SCREWS 4 PER SIDE (16 TOTAL) 350 LB WITHDRAWAL L ALLOWABLE PER SCREI 25. THE MAKE-UP AIR SUPPLY SHALL BE SHUT DOWN AR RESULT OF THE FIRE SUPPRESSION ACTIVATION. THE EXHAUST SYSTEM SHALL REMAIN ON DURING SUCH ACTIVATION. ALL ELECTRICAL EQUIPMENT UNDERNEATH THE HOOD SYSTEM SHALL BE SHUT DOWN UPON SYSTEM ACTATION AS WELL AS THE CLOSURE OF THE GAS VALVE SOLENIOD 27. THE LOCATIONS OF THE EXTINGUISHING AGENT CYLINDERS SHALL BE IN AN EASILY ACCESSIBLE LOCATION THAT WILL NOT SUBJECT THE CYLINDERS TO MECHANICAL OR CHEMICAL DAMAGE 10'-0" MIN. =RVI( SC01 INTAKE 8" ON CENTER AROUND PERIMETER OF FAN BASE # 10 TEX SCREWS (TOTAL OF 16 SCREWS) # 10 TEX SCREWS 4 PER SIDE (16 TOTAL) 350 LB WITHDRAWAL LOAD ALLOWABLE PER SCREW NOTE: ANY OFFSET OR DIRECTION CHANGE IN THE EXHAUST DUCT WORK WILL HAVE A CLEANOUT DOOR. WIND LOAD FASTENER SPECIFICATIONS TYPICAL FOR EXHAUST AND MAKE-UP AIR FANS EXHAUST FAN GREASE - Z COLLECTOR 0 z ao 6" IL_ MIN. CLR. BREAD OVEN K10 10'-0" MIN. EXHAUST FAN SUPPLY FAN ° ° SERVICE ° z_ U.L. LISTED DISCONNECT GREASE GREASE FAN CD COLLECTOR 705\762 71 INTAKE PROVIDE 3M F.R. DUCT WRAP TAPE Z (OR EQUAL APPL.) I i 16 Go ROOF II 1 FOR ANSUL HOOD I CURB M p EXHAUST AND To0 1 y 1 h I I SUPPLY DUCTS 1 M I :rZ// THAT ARE W/IN 6" I I R OF COMBUSTIBLE 1 I I MATERIAL/SURFACE. I I I 1 I PROVIDE 3M F.R. 24" X 10" 11 DUCT WRAP TAPE i SUPPLY DUCT M 11 (OR EQUAL APPL.) 9" X 10" 1 I 1----- I---- I M jI FOR ANSUL HOOD .� EXHAUST DUCT I r -L------------------- EXHAUST AND 00400 16 Go GALVINIZED I I I I ��11 i l SUPPLY DUCTS •� LIQUID TIGHT WELDED I 1 I I 1 max' THAT ARE W/IN 6" iw OF COMBUSTIBLE 3/8" THREADED ROD �I __ MATERIAL/SURFACE. 1 I T------------ L 1B O3 28 OO ® SUPPLY AIR D1N 10 11 DUCT 34 SN APLOC 5'-O" NOTE: NOTE: 6" FIELD VARIFY ALL HEAD �,6 �, FIELD VARIFY ALL HEAD CLEARANCES 111 CLEARANCES MIN, PRIOR TO MIN. MIN. PRIOR TO CLR. PURCHASING OF CLR. CLR. PURCHASING HOOD EQUIPMENT, HOOD SHALL OVERHANG COOKING OF HOOD SURFACE BY 6" MIN ON ALL OPEN SIDES. HOODS FRONTAL ELEVATIONS & SECTIONS r SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA HOOD ELEVATIONS KAA H ET NUMBER ff SAMUEL OLMEDO AR0015027 ---- ----- - -- -- - IOR _AB ER" 50 GPM GAL.) ICE MAKER ANTI -COAGULANT HEATER COIL & DRAIN LINE 30 GALLON WATER HEATER WALL MOUNT WALL MOUNT PLATFORM 3"0 VEN T . � F l 1 / 4"0 / VENT i 1 I / NEW ♦s . / VEGGIE / t CO SINK / NEW / 3"0 / I 3„� 3"� i W.C. F.D. VENT 1 s /� I W. C. 0. / t •I LAV. MEN *AIR 2" CLR. tK �LAV. � GAP �, p� 3" 0 F.S. -.� WOMEN 2»0 3"0 MECH VENT F.D. � LAV. I 11\ 14A,.er ` �W \ � W.C. CO. 2"o , G� F. D. tK / LAV. 4"0 F. C. 0. ICE MAKER 20 ANTI -COAGULANT MECH , L VENT HEATER COIL &DRAIN LINE ` � I 211 0 I SANITARY RISER PLUMB'G FIXTURE SPECIFICAT'N FIXTURE NUMBERS ARE AMERICAN STANDARD. SIMILAR FIXTURES BY ELJER OR KOHLER WILL BE CONSIDERED EQUAL DES'N DESCRIPTION MANUFACTURER CAT NO. TRIM SUPPLY WASTE VENT W/C WATER CLOSET FLOOR AMERICAN CADET WIDE ANGLE 1/2" CW 4" 2" MOUNTED FLUSH STANDARD 2292.100 WHEEL STOP LAV LAVATORY. WALL AMERICAN PENLYL CHICAGO 1/2" CW 2" 11/2" HUNG 8" HC STANDARD 0373-027 FAICET 408A-665 & HW WH WATER HEATER FD FLOOR DRAIN ZURN FD2321-PO3 STAINLESS _ 311 2" OR EQUAL STEEL COVER FS FLOOR SINK ZURN FD2376 OR STAINLESS _ 3 2 EQUAL STEEL COVER FC FLOOR CLEANOUT ZURN CO2500 OR BRASS COVER - 3' 2 EQUAL MS MOP SINK ZURN Z1996-24 STAINLESS 1/2" CW 2" 11 2" / OR EQUAL STEEL COVER & HW SF SERVICE FAUSET ZURN Z1996-SF STAINLESS 1/2" CW - - OR EQUAL STEEL COVER & HW PT PRIMER TRAP ZURN #Z-1000 TBRASS - - - OR EQUAL INTERIOR \ IN -SLAB \ "SCHIER" 50 GPM (249 GAL.) GREASE TANK FBC - PLUMBING 2010 TABLE 1003.5.1 - SIZING FORMULAS FOR GREASE INTERCEPTOR PRIVATE SEWAGE DISPOSAL SYSTEM (S) x (GS) x [HR/12 x (LE)] = EFFECTIVE CAPACITY OF GREASE INTERCEPTOR IN GALLONS 22 SEATS x 10 GAL. x [10HR/12HR x (.75)] _ 138 GALLON REQ'D PROVIDED: INTERIOR IN -SLAB "SCHIER" 50 GPM (249 tge PLUMBING LEGEND SANITARY WASTE PIPE GREASE WASTE PIPE VENT PIPING COLD WATER PIPING HOT WATER PIPE WALL CLEANOUT FLOOR CLEANOUT VENT THRU ROOF GATE VALVE PLAN NOTES s H O WCL 0 FC JL EXTEND AND CONNECT TO EXISTING 1 UNDERGROUND SANITARY PIPING. FIELD VERIFY EXISTING PIPE LOCATION. 2 EXTEND AND CONNECT TO EXISTING VENT PIPE. FIELD VERIFY EXISTING PIPE LOCATION. EXTEND AND CONNECT TO 2" DOMESTIC WATER LINE. FIELD VERIFY EXISTING PIPE LOCATION. NEW 30 GAL ELECTRIC WATER TANK. s c H _ SCOPE OF WORK: PLUMBING CONTRACTOR TO FIELD VARIFY LOCATION OF PROPOSED NEW & EXISINTG EQUIPMENT AND PLACEMENT, PRIOR BID & TO START OF WORK. ALL WORK IS SUBJECT TO EXISTING FIELD CONDITIONS THAT MAY ALTER THE DESIGN OF THIS PROJECT. SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR & MR. JOSHUA LINCOLN M. suss ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA SANITARY PLAN & SANITARY RISER np 1 A 1 /4„ = 1'-0" NOT TO SCALE AUEL OLMEDO AR0015027 T ---- --- - -- -- - - - -- --�--, - W.( WATT WATT PER DOMESTIC WATER RISER PLAN PLAN NOTES EXTEND AND CONNECT TO EXISTING 1 0 UNDERGROUND SANITARY PIPING. FIELD VERIFY EXISTING PIPE LOCATION. O EXTEND AND CONNECT TO EXISTING VENT PIPE. FIELD VERIFY EXISTING PIPE LOCATION. O EXTEND AND CONNECT TO 2" DOMESTIC WATER LINE. FIELD VERIFY EXISTING PIPE LOCATION. ® NEW 30 GL ELECTRIC WATER TANK. NOT TO SCALE GREASE WASTE PIPE SANITARY WASTE PIPE ►fx0mmIwIIto] COLD WATER PIPING HOT WATER PIPE WALL CLEANOUT FLOOR CLEANOUT VENT THRU ROOF GATE VALVE —«R—-— -— -— - —cR—-— (D WCL 0 FC JL IN NOTE: TRAP PRIMER VALVE WILL BE INSTALLED IN ACCORDANCE TO SECTION 1002.4 OF THE FLORIDA BUILDING CODE PLUMBING ZURN #Z2415B OR EQUAL FLOOR DRAIN DEEP SEAL P—TRAP ZURN #Z-1000 OR E( 1 - FLOOR DRAIN DETAIL NOT TO SCALE 140' TO 3 COMP SINK VACUUM BREAKER C.W. SUPPLY CHECK VALVE 110' H.W. SUPPLY HEAT TRAP BALL VALVE MIXING VALVE TEMP. AND PRESSURE RELIEF VALVE WATER HEATER RELIEF DISCHARGE PIPE TO FLOOR MOUNTED MOP SINK PROVIDE 6" MIN. AIR GAP qw 3-5/8" 20 GA. METAL STUDS SHUT OFF VALVE TANK DRAIN TYP. DRAIN PAN MIN. 1Y2" FIRE RATED PLYWOOD O O O FIRE RATED WOOD SOLID BLOCKING • 2"X2" 18 GA. UNI—STRUT 3/8" 0 LAG SCREW @ 6" O.C. OVERFLOW DRIAN PIPE TO FLOOR MOUNTED MOP SINK (DIA. TO MATCH RELIEF VALVE) PROVIDE 6" MIN. AIR GAP NOTES: 1. STORAGE WATER HEATER SYSTEMS THAT DO NOT INCLUDE A CIRCULATING SYSTEM SHALL HAVE A HEAT TRAP ON THE HOT AND COLD WATER LINES 2. DRAIN PAN SHALL BE 5" LARGER THAN THE TANK DIA. 2 -WATER HEATER DETAIL NOT TO SCALE NOTE: ALL PLUMBING WORK TO CONFORM TO 2010 EDITION OF FLORIDA BUILDING CODE - PLUMBING. 1.) ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPUCABLE LOCAL CODES, RULES AND ORDINANCES. 2.) PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3.) ALL MATERIALS SHALL BE NEW. 4.) ALL WORK SHALL BE PERFORMED BY A UCENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMALIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 5.) REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 6.) PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TEST, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTLES PRIOR TO BEGINING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. 7.) DRAWINGS ARE DIAGRAMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 8.) ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPTANCY TO ENGINEER / ARCHITECT PRIOR TO BEGINING CONSTRUCTION. 9.) VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINING OF CONSTRUCTION. ADVISE ENGINEER/ARCHITECT OF ANY DISCREPANCIES. 10.) WATER PIPING ABOVE & BELOW GRADE SHALL BE CPVC. 11.) SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE CAST IRON OR P.V.C. PVC MAY NOT BE USED THRU RATED ASSEMBUES OR IN PLENUMS. 12.) ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AN APPROPRIATLEY MARKED ACCESS PANELS, COORDINATE LOCATIONS WITH THE GENERAL CONTRACTOR PRIOR TO INSTALLATION, 13.) FURNISH AND INSTALL APPROVED AIR CHAMBERS AT EACH PLUMBING FIXTURE GROUP AS PER CODE AND WITH GOOD ENGINEERING PRACTICE. 14.) DIELECTRIC COUPLING ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS EXCEPT AT WATER HEATER AS PER CODE. 15.) RESERVE. 16.) ALL ARE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATIONS BY FILLING VOIDS BETWEEN PIPE AND WALL, FLOOR SLEEVES WITH FIRE RATED FOAM TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS AS PART OF THE PLUMBERS WORK. 17.) PLUMBING CON CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NO LESS THAN (1) ONE YEAR FROM THE DATE OF ACCEPTANCE BY OWNER CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE WITHIN 72 HRS OF NOTiFiCATION AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANYM OTHER PHASE OF INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 18.) PROViDE CHROM PLATED COMBINATiON COVER PLATE AND CLEANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS, 19.) NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES WHERE USED AS RETURN AIR PLENUMS. 20.) NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR EQUIPMENT ROOMS. 21.) CONDENSATE DRAIN LINES TO BE RUN UNDER SLAB IN P.V.C. SCH40 PIPE AND STUBBED OUT OF WALL TO UNIT. TIE IN OF A/C TO BE BY OTHERS. P.V.C. PIPING WITh 1/2" THICK ARAFLEX INSULATiON MAY BE USED IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. SEE PLUMBING DRAWINGS FOR SIZE AND LOCATION OF PIPING. P.V.C. WILL BE MIN. SCHEDULE 40 PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL SHUT OFF. CONDENSATE REMOVEAL SHALL COMPLY WITH SECTION 307 OF FBCM 22.) WATER PIPING INSULATION SHALL BE 10 THICK ARMAPLEX INSTALLED IN ACCORDANCE WITH MANUFACTURES INSTRUCTIONS FOR ALL HOT WATER PPING. WHERE DOMESTIC WATER TEMPERATURES CAN CAUSE SWEATING ALL COLD WATER PIPING SHALL BE INSULATED WITH 1/20 THICK ARMAPLEX INSULATION. 23.) STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL CODES, INSTALLATION SHALL BE AS PER MANUFACTURERS RECOMMENDATIONS, SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN M0 � . suss ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA DOMESTIC WATER RISER P2 NUMBER ?1.1 ELOLMEDO AR0015027 ----T--FT---T- I I f f GAS PLAN 1 /4" = 1'-0" GAS LINE BY GAS COMPANY tln 17, 1 & 2 - HR FIRE RATED CONDUIT PENTRATION @ FRAME WALL NOT TO SCALE 2 - GAS PIPE SUPPORT DETAIL NOT TO SCALE all 0 3 �� �ASAJNW�q ���� �. _ 7e PLUMBING � o !Rx VALA WAU . QUICK DISCIDNN --3 — - SUPER *�E GAS, ICaNNIECTOIIR z I s a "KITCHEN GAS APPLMCE r 4SA FLOOR, RE$ WAIN14" 3 - KITCHEN EQUIPMENT CONNECTION NOT TO SCALE NOTE: ALL INSTALLATION OF GAS PIPING AND APPLIANCES WORK TO CONFORM TO 2010 EDITION OF FLORIDA BUILDING CODE FUEL AND GAS. 1. INSTALL GAS SERVICE WITH MAIN CUT—OFF VALVE @ OUTSIDE OF METER AND EXTEND AS SHOWN. 1 /Z RGEr CCE 1 1 /4" BY GAS COMPANY CAS METER 9s GAS RISER NOT TO SCALE GAS CALCS PER 2010 FLORIDA BUILDING CODE FUEL AND GAS WITH 2O12 AMENDMENTS. TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE TOTAL DEVELOPED LENGTH = 70 FEET SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN J� 1l� IV SUBS ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA GAS PLAN & RISER p 'I (SHJET NUMBER Ir AKUU 1 bU2 ELECTRICAL LEGEND NEW RTU #1 6 TON 0 �} I_�1�-� IIIIIIIIIIIIIIIIIIIIIIIIIIIIilllllllllllllllllll "" I� IIIIIIIIIIIIIIIIIIIIIIIIIIIIilllllllllllllllllll /�� �1�■I�I. anunun"uuunuuunuuunuuuur. y1,3 IIIIII 0 IIIIIII -=== ,Llz:�l I I \ W z O z F- X W O .�7,39,41 0 a m NEW W KIN COOLER CONDEN ER ROOF TOP UNIT REMOTE CAPSULE PAK A1to,17 8 B3 A32,34,36 , 25 IVAI LJ A30 42" GFI A29 RTU/GFCI GI milli, _ ■I■li • i A20 I �I • • r IM • CLG ---J B18 J TO CLOCK TIMER EXT. J.M. SIGN - UNDER SEPERATE PERMIT — — — — — — — — — — — — — — — — — — — — — — — — — J GFCI NOTE: ALL 15 AMP AND 20 AMP 125 VOLT RECEPTACLES REQUIRE GFCI PROTECTION IN KITCHEN AREAS. POWER PLAN - ALTERATIONS JEW RTU #1 TON 1 /4" = 1'-01 I I• LIGHTING PLAN - ALTERATIONS 1 /4" = 1'-0" SYMBOL DESCRIPTION COMMENTS X 3 - BE PRISMATIC (ACRYLIC) FLUORESCENT LT. LENSES FIXTURES A.C.T. GRID MINT. 24" X 48" PARABOLIC LENSES 3 - TUBE FIXTURES FLUORESCENT LT. A.C.T. GRID MINT. 24"X 24" 1771 3 - TUBE PRISMATIC (ACRYLIC) FLUORESCENT LT. LENSES FIXTURES A.C.T. GRID MINT. 24" X 24" PARABOLIC LENSES 3 - TUBE FIXTURES FLUORESCENT LT. A.C.T. GRID MINT. SINGLE TUBE FLUORESCENT LT. RECESSED CAN LT. CLG MINT SURFACE MOUNTED INCANDESCENT SURFACE MOUNTED PULL -CHAIN -0-PC INCANDESCENT SWITCH C CHANDELIER CEILING MOUNTED WALL MOUNTED INCANDESCENT 0 0 0 TRACK LIGHTING CEILING MOUNTED INCANDESCENT LIGHT & FAN EMERGENCY LIGHT & EXIT LIGHT COMBO 00 EMERGENCY LIGHT ® EXIT LIGHT SPEAKERS WALL OUTLET 18" ABOVE FIN. FLR. (9'42 42" A.F.F. WALL OUTLET CLG CEILING MOUNT DUPLEX FOUR PLEX WALL OUTLET EXISTING OUTLET FIELD VARIFY ® DIRECT CONNECTION JUNCTION DISCONNECT ELECTRICAL PANEL SINGLE POLE SWITCH $2 SINGLE POLE TWO-WAY SWITCH ,- 0 HVAC THERMO-STAT 42" A.F.F. �� WALL MOUNT TELEPHONE I�p DATA OCCUPANCY SENSOR DELAY. WALL MOUNT os SWITCH W/ TIME 42" A.F.F. os OCCUPANCY SENSOR CEILING MOUNT SWITCH W/ TIME Irc rINTERMATIC TIME CLOCK MOUNT ADJACENT TO POWER PANEL 60" A.F.F. HVAC LEGEND El A/C DIFFUSER CLG. VENT A/C RETURN AIR RA CLG. GRILL HVAC NOTE: ALL EXISTING HVAC SYSTEMS TO REMAIN, AS IS, UNLESS NOTED OTHERWISE ON DEMOLITIONS PLANS, AND / OR ALTERATION PLANS. FIRE PROTECTION Q• EXISTING SPRINKLER HEAD PROPOSED NEW O TO REMAIN OR RELOCATE SPRINKLER HEAD F.E. >0 EXISTING FIRE-EXTINGUISHER 4 EXISTING FIRE -ALARM PULL STATION NOTES: `* 1. PROTECT OUTLET BOXES WITH FIRE RATED CAULK OR PUTTY PADS. ELECTRICAL DETAIL 1 HOUR FIRE RATED WALLS DEVICE'S BOX INSTALLATION NOTE: NOT TO SCALE ALL ELECTRICAL OUTLETS PENETRATING FIRE RATED WALL SHALL MEET PROTECTION. SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT, THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR & MR. JOSHUA LINCOLN ZEPHYR COMMONS SHOPPING CENTER 7890 HWY 301 ZEPHYRHILLS FLORIDA POWER & LIGHTING PLAN nEET NUMBER i� I EL OLMEDO 10015027 Tf— I Ti -T I I_ 1 I..... 1-ITS- I.— NOTES: 1. EMERGENCY/EXIT LIGHTS SHALL BE CONNECTED TO LOCAL AREA LIGHTING CICUIT AHEAD OF ANY SWITCHING DEVICES PER NEC 701.11 (F). EMERGENCY LIGHTING SHALL PROVIDE A MINIMUM OF 1 FOOT CANDLE OF ILLUMINATION FOR ALL EGRESS WALKWAYS. ADDITION FIXTURES MAY BE REQUIRED. 2. ALL 15 AMP AND 20 AMP 125 VOLT RECEPTACLES REQUIRE GFCI PROTECTION IN KITCHEN AREAS. 3. ALL EQUIPMENT REQUIREMENTS MUST BE VARIFIED WITH ACTUAL EQUIPMENT DELIVERED TO SITE. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ADJUSTING ELECTRICAL REQUIREMENTS AS NEEDED. 4. ELECTRICAL CONTRACTOR TO FEILD VARIFY AND TRACE EACH CICUIT FOR CORRECT BREAKER LOAD AND SIZE. REFER TO SPECIFIC EQUIPMENT LABEL OR CUT SHEET AS REQUIRED TO MEET N.E.C. 5. PROVIDE 1" C WITH BELDEN SHEILD #8132 FROM P.O.S. TO EXISTING TELEPHONE EQUIPMENT BOARD AT REAR OF STORE. REGISTER TO HAVE (2) RJ-11 JACKS. 6. ALL CONDUITS SHALL BE 1" UNLESS NOTED OTHERWISE. 7. ALL EQUIPMENT CUT -SHEET DESIGNATING ELECTRICAL POWER AND BREAKER REQUIREMENTS SHALL BE VERIFIED WITH THE PANEL SCHEDULE PRIOR TO WORK. ANY DISCREPENCIES SHALL BE BROUGHT TO ATTENTION OF THE DESIGN PROFESSIONAL. SPECIFICATIONS CONSTRUCTION OF ANY OF THE ELECTRICAL WORK SPECIFIED HEREIN SHALL CONFORM TO THE REQUIREMENTS OF THE APPLICABLE SECTIONS OF THE NATIONAL ELECTRICAL CODE RACEWAYS:EMT WITH SETSCREW FITTING, MC �, A p,Q ND VULNERABLE TO MECHANICAL INJURY BSHALLEBIBLAU" ,TI�F��Y-o WTCH'v`AINl* STEELEOR ALUMINUM. ALUMINUM CONDUIRS. CONDUITS RUN TS MAY MAAYSED ANOT BE USED BELOW GRADE OR EMBEDDED IN CONCRETE. CONDUITS RUN EXPOSED OUTSIDE OR IN FLOOR SLABS SHALL BE RIGID, HEAVY --WALL, GALVANIZED OR SHERARDIZED STEEL. CONDUITS RUN BELOW GRADE, EXTERIOR TO THE BUILDING SHALL BE SCHEDULE 40 HEAVY --WALL, HIGH IMPACT POLYVINYL CHLORIDE ELECTRICAL CONDUIT. BOXES: OUTLET BOXES AND COVERS SHALL BE GALVANIZED OR SHRARRDIZED, ONE-PIECE PRESSED STEEL, KNOCKOUT TYPE, AND OF AN APPROVED MAKE. OUTLET BOXES SHALL BE EQUIPPED WITH PLASTER RING, EXTENSION RINGS OR FIXTURE STUDS AS MAY BE REQUIRED. DO NOT INSTALL BOXES BACK TO BACK. BOXES EXPOSED TO RAIN OR OTHER MOISTURE SHALL BE CROUSE--HINDS TYPE ES, FD CONDULET BOXES WITH APPROPRIATE COVERS AND GASKETS. DEVICES: 1- RECEPTACLES: DUPLEX 20 AMP CONVENIENCE RECEPTACLES (COLOR AS SELECTED BY ARCHITECT,) 120-VOLT GROUNDING TYPE, SHALL HAVE TWO CURRENT -CARRYING CONTACTS AND ONE GROUNDING CONTACT WHICH IS INTENTIONALLY CONNECTED TO THE FRAME. (ONLY P&S, HUBBELL OR LEVITON ARE APPROVED). GROUND FAULT RECEPTACLE SHALL BE DUPLEX TYPE. WEATHERPROOF DEVICES: ALL RECEPTACLES, SWITCHES AND JUNCTION BOXES ON NE EXTERIOR OF THE BUILDING, ON THE ROOF, OR IN LANDSCAPED AREAS SHALL HAVE A WEATHERPROOF LIFT COVER PLATE. 2- SWITCHES : PROVIDE COMMERCIAL GRADE FLUSH MOUNTING QUIET -OPERATING AC TYPE WITH TOGGLE OPERATOR HEAT-RESISTNCE PLASTIC HOUSING AND SELF GROUNDING METAL STRAP. SILVER OR SILVER ALLOY CONTACT. DESIGN FOR SIDE OR BACK WIRING WITH UP TO NUMBER 10 WIRE, VERIFIED BY UL TO MEET OR EXCEED FEDERAL SPECIFICATION WS-896E USE SINGLE -POLE DOUBLE -POLE 3-WAY 4-WAY LIGHTED, P1LOT OR KEYED TYPE, AS INDICATED ON DRAWINGS OR REQUIRED. CONDUCTORS: FURNISH & INSTALL CONDUCTORS OF THE SIZE AND TYPE SHOWN ON THIS DRAWING. ALL CONDUCTORS SHALL BE COPPER, TYPE THHN/THWN AND RATED AT 600 VOLTS. ALL SIZES ARE THE MINIMUM ACCEPTABLE TO SATISFY AMPACITY REQUIREMENT. CONSIDERATION SHALL BE GIVEN TO VOLTAGE DROP AND INSULATION SCCR WHERE NECESSARY. 20A CIRCUITS GREATER THEN 75 FT IN LENGTH SHALL BE #10 AWG MINIMUM 20A CIRCUITS GREATER THAN 130 FT IN LENGTH SHALL BE #8 AWG MINIMUM, CHANGE TO #12 AT JBOX AHEAD OF FIRST RECEPTACLE. GROUNDING: 1. ALL GROUND WIRES AND BONDING JUMPERS SHALL BE COPPER INSTALLED IN CONDUIT. ALL GROUND WIRES SHALL BE WITHOUT JOINTS AND SPLICES OVER ITS ENTIRE LENGTH. 2. THE SYSTEM NEUTRAL SHALL BE GROUNDED AT THE SERVICE ENTRANCE ONLY, AND KEPT ISOLATED FOR GROUNDING SYSTEM THROUGHOUT THE BUILDING. 3. EACH SYSTEM OF CONTINUOUS METALLIC PIPING AND DUCTWORK SHALL BE GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE. 4. MECHANICAL EQUIPMENT SHALL BE BONDED TO THE BUILDING EQUIPMENT GROUNDING SYSTEM. THIS SHALL INCLUDE BUT IS NOT LIMITED TO FANS, PUMPS CHILLERS ETC. EMERGENCY CIRCUITS: CONNECT ALL EMERGENCY LIGHTING (EXIT LIGHTS) ON THE SAME CIRCUIT AS THE NORMAL LIGHTING IN THE AREA AHEAD OF ANY SWITCHES AND/OR COMPLY WITH NEC 700-12(e). RESPONSIBILITIES: CONTRACTOR IS RESPONSIBLE TO IDENTIFY ALL UNDERGROUND UTILITIES PRIOR TO START OF EXCAVATION. THE DRAWING SHALL ONLY BE USED AS A GUIDE, BASED ON EXISTING INFORMATION THAT WAS AVAILABLE. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL EXISTING CONDITdp!IONS AND TO COMMUNICATE WITH THE ARCHITEC/OWNER ANY CONTRADICTIONS WITH THE DESIGN INTENTION. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE FIXTURE CATALOG NUMBERS TO ENSURE COMPLIANCE WITH THE OTHER FACILITIES. IF THERE IS ANY DISCREPANCY, OR THE EXISTING MATERIAL IS NO LONGER AVAILABLE, THEN CONTRACTOR SHALL SPECIFY THAT IN HIS BID AND SUBMIT AN EQUIVALENT SUBSTITUTE FOR APPROVAL BY THE OWNER. VOLTAGE DROP:THE CONTRACTOR IS RESPONSIBLE TO SIZE ALL WIRES TO MEET NEC FOR VOLTAGE DROP. THE FOLLOWING RULE OF THUMB CAN BE USE FOR 20A-120V CIRCUITS: #12 MAX LENGTH 60FT, #10 MAX LENGTH 95FT, #8 MAX LENGTH 155FT. 120V ELECTRICAL CONTRACTOR SHALL J GFI KiUU PROVIDE 120 VOLT CIRCUIT FOR wF' SMOKE DETECTORS PROVIDED BY MECHANICAL. VERIFY WITH MECH. SEE PANEL FOR EXACT LOCATION. (TYP.) SCHEDULE DISCONNECT SWITCH AND GFI RECEPTACLE INTEGRAL W/ ROOFTOP UNIT (TYP) 1. VERIFY NAMEPLATE RATINGS, LOCATIONS, AND POINT OF POWER CONNECTIONS PRIOR TO START OF PROJECT. 2. DO NOT LOCATE DISCONNECT SWITCHES OVER UNIT ACCESS PANELS. 3. PROVIDE A 3/4" EMPTY CONDUIT THROUGH INACCESSIBLE LOCATIONS (I.E. WALLS, UNDER SLAB) FOR CONTROL WIRING. COORDINATE WITH MECHANICAL PLANS. 4. ELECTRICAL DISCONNECT SWITCHES, CONDUIT AND WIRE SHOWN ARE SIZED, AS PER THE MANUFACTURER AND MODEL NUMBER LISTED ON MECHANICAL PLANS. IF THERE IS AN EQUAL MANUFACTURER, OR OTHER MANUFACTURER PROVIDED, THE MECHANICAL/ GENERAL CONTRACTOR SHALL BEAR ANY ADDITIONAL COST INCURRED IF THE ELECTRICAL IS NOT EQUAL TO SPECIFICATIONS. 5. ELECTRICAL CONTRACTOR SHALL INSTALL ALL STARTERS FURNISHED BY MECHANICAL CONTRACTOR AND SHALL MAKE ALL REQUIRED CONNECTIONS UNLESS STARTERS ARE SPECIFICALLY NOTED ON MECHANICAL PLANS TO BE FACTORY INSTALLED (SEE NOTE 4). MECH. EQUIP. POWER WIRING DETAILS N.T.S. LIGHTING FIXTURE (LUMINAIRE) SCHEDULE TYPE CATALOG NUMBER NO. LAMPS/TYPE W,",TTS I VOLTS I MOUNTING DESCRIPTION PROJECT LIGHTING NOTES: 1. ALL EMERGENCY LIGHTS MUST HAVE CONSTANT POWER FROM THE BREAKER. 2. ALL EMERGENCY LIGHTS MUST BE CONNECTED TO THE LOCAL LIGHTING CIRCUIT IN CASE OF POWER FAILURE EVENT IN THE SAME AREA. 3. ALL EMERGENCY LIGHTS UNITS MUST BE ORIENTED TOWARD THE EGRESS PATH INDICATED ON LIFE AND SAFETY PLAN. EM - DENOTES EMERGENCY POWER UNIT PROVIDED WITHIN THE SAME LUMINARE. NIL - DENOTES 24 HOURS LIGHT LUMINAIRE SCHEDULE NOTES: 1. ALL LIGHTING FIXTURES AND LAMPS IN THE ABOVE SCHEDULE ARE PROVIDED BY THE CONTRACTOR VIA A NATIONAL CONTRACT WITH HERMITAGE LIGHTING NATIONAL ACCOUNTS. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING THE LIGHTING FIXTURES. ANY QUESTIONS REGARDING FIXTURE AND LAMP TYPES AND INSTALLATION REQUIREMENTS SHALL BE WITH WYATT CULVER OF HERMITAGE LIGHTING AT (800) 264-3383. OR (615) 843-3379. 2. RECESSED DOWN LIGHTS ARE AVAILABLE AS EITHER Cl, C2, OR C3 AS SPECIFIED BY OWNER. FOOD SAFE TRIM AVAILABLE AS NEEDED WHEN REQUIRED (PART #18622309) 3. TYPES W2 AND P2 ARE ALTERNATES FOR STORES IN CALIFORNIA AND OTHER STATES W/ WATTS/ SQFT RESTRICTIONS SUCH AS TITLE 24 PANEL DESIGNATION PANEL A "ET SURFACE MOUNTED SIEMANS TYPE 208Y/120V,30,4W 10,000 A.I.C. (INTEGRATED 200A MLO COMMENTS GND LOAD V.A. GND AO Bo COCIR CIR # TRIP POLES WIRE WIRE COND LOAD # TRIP POLES WIRE WIRE COND LOAD 1 -- - 30 2 2#10 1#10 1/2" ELECTRIC WATER HEATER 720/1400 ----- --------------- 2 -- - 20 --- _ 1 __ 2#12_ 1#12 112" --_ DRINKS DISPLAY -CASE ------------------------ 3 540/1400 _ 4-- 20 - - 1_- 2112 1#12 jZ __-SANDWICH UNIT--------- ---------------- 5 20 2#12 1 #10 1 /2" BAG _IN _BOX-(PEPSI) 540/114 _ 6 20 _ 1-_ 2#12 --1 #12 1/2" .WALL OUTLETS --------- ---------------- -- ---2-- ---- - - - - - - - - - _ __ 0 1 SANDWICH --- g 40 3 3#8 1 #10 3 4" / BREAD OVEN ------ ------- 583/3200 - _ -------- _-_---- --- 10 _ 20 - - 2 2#12 1#10 1/2" -UNIT -------------------- ANSUL HOOD SF-1 ---------------- - - - - - - - - - - - - - - - - 11 ---------------- 583/3200 12 --- --- -------- --- _________ - ---------------- --- 13 -- 20 --- ---- 2##10 --- 1_#10 --- 1/2" --------------------------- HEAT HOOD EF-2 ------ 11_37/1137 14 2_0 1-- 212 1#12 �2" ANSUL HOOD EF-1------- 15 -2- ---- ----------- ---------------- 180/790 _ 16 20 - 1 2&12_ 1#12 �2" --- ANSUL-CONTROL ___ � S'--- --- 17 --- 20 -- 2 --- 2#12 ---- 1#12 --- 1/2" --- WALK-IN COOLER --------------------------- ----- ------ -- - --------1200/790- -------- --- 18 --- --- 20 --- --- -1-- 2#12 1 #12 1/2" _-_ --------lQ4D -COUNTER FOOD WARMER --------- -----�- --------- 19 - -- 20 2 2#12 1 #12 1 /2" WALK. -IN FREEZER 540/790 ----- - - - - - - - - - - - - - - - 20 ­20 - - 1 - 2#12_ 1 #12 �2" --- MEAT SLICER----------- - - - - - - - - - - - - - - - - 21 ____ - 1152/790--------- 22 - 20 - - 1-- 2#12 1#12 f2" - - - MEAT DISPLAY -CASE ------ - - - - - - - - - - - - - - - - 2320 -1 - 2112 1#12 1/2" ----UNDERCOUNTER REF. (FUTURE) - - - --- _____ - - - - - - - 1400/600 _ 24 20 - 1-- 212 1#12 .-1/2"---- IC_E_-_M_AK_E_R____________ --- --------------- 25 --- 20 -- _1_ 2#12 - 1#12 - ____MEAT SLICER - --- 360/540 --- - ---------------- 26 --- 20 --- - 1--2#12 1#12 --- 1/2" - CASH REGISTER ------------------------- --------------- 2_7__ 20 _1 _ _2_ #12 1#12 4' DROP_IN ________ ------- ------ 1116/624--------- - 28 --- 20 --- - 1-- 2#12 1#12 --- 1/2" - SODA DISPENSOR ---------------------- - - - - - - - - - - - - 29 20 20 _1_ 2 212 - 2#12 1#12 - 1 #12 1 /2" COUNTER FOOD WARMER ------------- UNDERCOUNTER MICROWAVE ------ 4800/490 -- ______ _______ 4800/490 ------ 360/1200_ _______ ------- 30 --- _32_ 34 --- 20 --- 60 - 1--2#12 3 3#6 1#12 --1/2"---- --- 1#10 - 3/4" W.P OUTLET--- RTU#2 - - - - - - - - - - - - - - - - ---------------- ---------------- 31__ 33 35 20_ _1 _ 2#12 1#12 1/2" RTU#1 ROOF W.P OUTLET 2070 4800 4800/360 36 38 4 - #3 Thhn COPPER 37 --- 39 60 3 3#6 1 #10 3/4" RTU#1 - - - - - - ------- 1916/4800 ----- -- 40- 100 3 4/3 1 #8 1 1/2" PANEL B 1 - #8 Thhn COPPER --- 41 ------ ------- ----- ---- 3324/480 --- 42 1 1/2 C VA = AMPS 21,624 VA 23,171 VA 1 23,271 120A 180.20 A 1193.01 A 193.93 A PANEL DESIGNATION PANEL B "EQ" SURFACE MOUNTED SIEMANS TYPE 208Y/120V,30,4W 10,000 A.I.C. (INTEGRATED 100A M LO COMMENTS GND LOAD V.A. GND AO Bo CO CIR TRIP POLES WIRE WIRE COND LOAD CIR # TRIP POLES WIRE WIRE COND LOAD 1 20 #12 1 /2" ICE _____________ 307/1440 2 ___ 20 _ 1-- 2_#12 1 #12 �2" REAR DINING LIGHTS______ ---------------- 3 20 -1 _ 1 _2112 2#12 -1 #12 -TEA -BREWER CLG &_TV OULETS _ ________________ 340/900 4 20 1-- 2#12 1#12 FRONT DINING - - 1 - 2#12 -1 1#12 1/2" ________ EXTERIOR 6-- 20 - 1--_?.#12 #12 ___ -LIGHTS----- SOFFIT LIGHTS - - - - - - - - - - - - - - -5---20 --- 7-- --- -- ----FUTURE -SIGN ________ SPARE ______ 303/0 _________336/1200- 8 - - 212 -1 1#12 �2" - - - _________ KITCHEN LIGHTS 9 -- --- ---- --- --- --------------------------- SPARE ------ ---------------- 316/0 - --20 10 --- 20 -1_- 1-- 2#12 1#12 �2" _ TOILETS LIGHTS_________ --- 11 -- --- ---- --- --- --------------------------- SPARE ------ ------------ ---_ 588/0 _ 12 - 20 - 1__ 2_#12 1412 �2" PREP AREA LIGHTS --- 13 -- --- ---- --- --- --------------------------- SPARE ---- - 120/0 ---------------- --- 14 --- 20 - 1 2#12 1 #12 1 /2" ------------------------- FREEZER/COOLER LIGHTS___ --------------- 15 --- --- ___________________ SPARE ------ --------------- 360/0---------- --- 16 --- 20 ------ 1 2�12 --- #12 - 1 /2" ___ PHONE/FAX ---------------- --- 17 -- --- ---- --- ----- --- - - - - ------------------- SPARE - - 1200/0 - 1 g --- 20 - __ 1 --1 2#12 1 #12 1 /2" - - - - - - - - - - - - - - FUTURE EXTERIOR SIGN --- 19 -- --- ---- --- --- --------------------------- SPARE ------ 0/0 ---------------- --- 20 --- -------- --- --- ------------------------- SPARE --------------- --- 21 -- --- ---- --- --- --------------------------- SPARE ------ ---------------- 0/0 --- 22 --- -------- --- --- ---------------------- SPARE ---------------- --- 23 -- --- ---- --- --- --------------------------- SPARE ------ ---------------- 0/0 --- 24 --- -------- --- --- ---------------------- SPARE ---------------- --- 25 -- --- ---- --- --- --------------------------- SPARE ------ 0/0 ---------------- --- 26 --- -------- --- --- ---------------------- SPARE - - - - - - - - - - - - - - - - 27 SPARE 0/0 28 SPARE 29 -- --- ---- --- --- SPARE --------------------------- SPARE - - - - - - 0/0 ---------------- 0/0 30 --- 32 --- -------- --- --- SPARE ------------------------- SPARE --------------- 31 --- 33 -- --- ---- --- --- --------------------------- SPARE ------ -- 07------------ 0/0 -34-- --- -------- --- --- ---- SPARE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 35 -- --- ---- ---- --- --- --- --- --------------------------- SPARE --------------------------- SPARE ------ ------ 0/0 ---------------- ---------------- 0/0 --- 36 --- 38 --- --- -------- -------- --- --- --- --- ---------------------- SPARE ------------------------- SPARE ---------------- --------------- 37 39 --- ---- --- --- --------------------------- SPARE ------ ---------------- 0/0 --- 40 --- -------- --- --- ---------------------- SPARE ---------------- --- 41 -- --- ---- --- --- --------------------------- SPARE ------ ---------------- 0/0 --- 42 --- -------- --- --- ---------------------- SPARE ---------------- VA = AMPS 120A LOAD CALCULATIONS PANEL A DESCRIPTION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD GENERAL LIGHTING 6.12 KVA 1.25 7.65 KVA -------------- RECEPTICLES ----------------------------------------- 3.94 KVA 1.00 3_94 KVA -------------- A/C --------------- 17.95 KVA --- 1.00 17.95 --- KVA -------------- KITCHEN EQUIPMENT ----------------------------------------- KVA 0.65 20.45 KVA ----------------------------------------------------- - MISCELLANOUS -31.46 8.86 KVA 1.00 8.86 KVA TOTAL 68.33 KVA 58.85 KVA -KVA ------------- TOTAL AMPS ----------------------------------------- 189.89 KVA 163.55 KVA PANEL A CONNECTED LOAD 68.33 KVA X 1000 = 328.51 VA / 1.73 = 189.89 A 208V. DEMAND LOAD 58.85 KVA X 1000 = 282.93 VA / 1.73 = 163.55 A 208V EXISTING BUILDIN EXISTING OUTDOOR WIREWAY UTILITY TRANSFORMER (208Y/120V, 30,4W) BUILDING SERVICE LOAD CALCULATIONS (AS PER T.E.C.O.) EXISTING TRANSFORMER HAS 2002 AMPS LOADED AT 34% EXISTING 800 AMP MAIN PEAK DEMAND TABULATED AT 294 AMPS, THIS INFORMATION IS PROVIDED BY T.E.C.O. 2" RIGID GALVANIZED CONDUIT WITH 4 #3/0 AND 1 #6G. METER 250A 30 4-WIRE NEMA 3R ENCLOSURE FUSED DISCONNECT 250A 30 4-WIRE NEMA 3R ENCLOSURE I I I I WITH 4 #3/0 AND 1 #6G, I-----------) I TO EXISTING PANEL I I I ( TO EXISTING_PANEL _ __ _ _ I l_TO_PAE_XISTING PANEL �` TO EXISTING NEL EXITING GROUND ROD - TO BE A MINIMUM 5/8"0 X 8'-0" LONG _i (MIN.) COPPERWELD GROUND ROD INSTALLED VERTICALLY IN GROUND W/ A 12" CLEARANCE FROM WALL FOUNDATION, AND 6" GROUND COVER. NEW JERSEY MIKE'S TENANT SPACE NEW NEW SUB - PANEL "A" PANEL "B" 200 AMP 200 AMP 30, 4 WIRE 30, 4 WIRE NEMA 3R NEMA 3R 42 CKT 42 CKT 7 ELECTRICAL RISER 3 - #4/3 THHN COPPER, 1 /#8 THHN COP IN 1-1/4" C. NOT TO SCALE SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA ELECTRICAL PANEL SCHEDULES & RISER DIAGRAM E2 SHEET NUMBER r DUEL OLMEDO AR0015027 1 & 2 - HR FIRE RATED ELECTRICAL FLEX CONDUIT @FRAME WALL NOT TO SCALE 1 & 2 - HR FIRE RATED CONDUIT PIPE @ FRAME WALL NOT TO SCALE 1 - HR FIRE RATED PIPE PENTRATION @FRAME WALL NOT TO SCALE SAMUEL OLMEDO ARCHITECT FL. REG. AR0015027 TEL. 407. 967. 3109 soarcht @ yahoo.com P.O. BOX 784825 WINTER GARDEN, FL. 34778 CONSULTANT CONSULTANT REVISIONS: NO . DATE DESCRIPTION INSTRUMENTS OF SERVICE OWNERSHIP ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES INSTRUMENTS PREPARED BY THE AND OTHER DOCUMENTS AND RELATED INSTRUMENTS PREPARED BY THE ARCHITECT OR CONSULTANTS AS INTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR CONSULTANT. THE ARCHITECT AND OR THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. MR. RANDY HAGAR MR. JOSHUA LINCOLN M9 G� D . Suss ZEPHYR COMMONS SHOPPING CENTER 7890 H WY 301 ZEPHYRHILLS FLORIDA FIRE RATED PENETRATIONS DETAILS FR1 IsfET NUMBER -d1 AUEL OLMEDO AR0015027 -�T-- - -- ---