HomeMy WebLinkAbout7894 Gall BlvdINTERIOR RENOVATION NEW IN EXISTING COMMERCIAL BAY AT N i, 7894 GALL BOULEVARD ZEPHYRHILLS, FLORIDA 33541 FOR HEAR USA INDEX SHEET DESCRIPTION SHEET No. Awl EXISTING FLOOR PLAN 1 OF 7 A=2 PROPOSED FLOOR PLAN 2 OF 7 Aw3 REFLECTED CEILING PLAN & ELEVATION 3 OF 7 Ent ELECTRICAL PLAN mot MECHANICAL PLAN Pot PLUMBLING PLAN Pm2 PLUMBING RISERS AND NOTES 4 OF 7 5 OF 7 6 OF 7 7 OF 7 MDS ENGINEERING CORP. A FLORIDA DESIGN & ENGINEERING CORPORATION C.A.#28051 21809 SW 99th AVENUE CUTLER BAY, FL 33190 Phone:(786) 436-7062 / Fax: (305) 412-2759 E-mail: marioduany@mdsengineeringcorp.com LS�v �frtI V L, PREVAIL, CODES, FLOC, EUILDI rC CODE, NA ION AL ELECT COVE AN CITY OF z'ErIiYRHsLLS ORD' A1NCL'S DATE '�_!Ty OF GE 'HYRHILLS (S -7 9 7 z/ 6 L 1-1 D �Fss dNA���C� LOCATION ADDRESS: 7894 Gail Boulevard Zephyrhills, FL 33541 SCOPE OF WORK —PROVIDE NEW OFFICE SPACES LAYOUT —NEW 1 HOUR FIRE RATED TENANT SEPARATION —NEW PAINT FOR NEW OFFICE SPACE —NEW ELECTRICAL WORK WIRES & FIXTURES (NEW OFFICE SPACE ONLY)) —NEW GRILLES AND A/C DUCT WORK AS PER NEW LAYOUT —NEW BATHROOM AND NEW SINK FOLIO NUMBER: 35-25-0130-00000-0030 SUBDIVISION: Zephyr Commons Phase 1 ZONING DESIGNATION: HEAR USA 7894 GALL COMMERCIAL BUSINESS OCCUPANT LOAD: BUSINESS AREAS: 1/100 SF GROSS ACCORDANCE WITH TABLE 1004.1.2 OF F.B.C. 2014) BUSINESS AREAS:: 1184 SF GROSS /100 = 11.84 PEOPLE TOTAL OCCUPANT LOAD = 12 PERSONS PERMIT NOTES: OCCUPANCY TYPE: USE: GROUP B (This informstion is in accordance with FBC 2014 Chapter 3) CONSTRUCTION TYPE: TYPE: V (B) (PROTECTED) (This informstion is in accordance with FBC 2014 Chapter 6) FLAME SPREAD CLASSIFICATION: THE INTERIOR FINISHES FLAME SPREAD CLASSIFICATION IS: "C" FLAMESPREAD 76-200, SMOKE DEVELOPED 0-450. SPRINKLERS NOTE: THERE ARE NOT SPRINKLERS IN THIS BUIDING FINISH NOTE: ALL INTERIOR FINISH OF GROUP B SHALL COMPLY WITH TABLE 803.9 OF FBC 2010 AS SHOWN BELOW. INTFRIOR WAI I ANR (TII IN(; FINICH RFnI IIRFMFNTC RY IN l i IPAN(`Y SPRINKLERED ROOM AND ENCLOSED GROUP EXITS ENCLOSURES CORRIDORS SPACES AND PASSAGEWAYS C GROUP B B C EXTERIOR WALL RATED: 1 HOUR (IN ACCORDANCE WITH TABLE 503 OF F.B.C. 2014) FIRE & SMOKE SEPARATION WALLS: THE FIRE &/OR SMOKE SEPARATION WALLS AND PARTITION SHALL BE IDENTIFIED W/ STENCILED SIGNS. BUSINESS NOTE: THIS BUSINESS IS TO PROVIDE PROFESSIONAL SERVICES AND SUPPORT FOR PEOPLE WITH HEARING PROBLEMS, INCLUDING HEARING TESTS AND EQUIPMENTS. THE LAB IS ONLY USE FOR THE REPAIR AND MAINTENANCE OF IMPAIRMENT DEVICES, NOT CHEMICAL NOR OTHER HAZARDOUS SUBSTANCE IS GOING TO BE USE IN THIS FACILITY. 2" COPPER PIPE WATER LINE 2.5" / 1 " PVC PIPE CONDUITS TO ELECTRICAL SERVICE & DMARC. 145 LF APPROX. 'qWwMisr-', %ftIIt%fi=:j n11 f :ra= LOCATION PLAN N.T.S. BOULEVARD GENERAL NOTES: 1.— ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE 2014. ANY DISCREPANCIES BETWEEN THE PLANS AND ABOVE REQUIREMENTS MUST BE CALL TO THE A/E'S ATTENTION BEFORE PROCEEDING WITH THE WORKS. 2.— THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE PLANS, HE MUST FAMILIARIZE HIMSELF WITH THE CONTRACT DOCUMENTS BEFORE PROCEEDING WITH THE WORK AND REPORT TO A/E TO CLARIFY ANY DISCREPANCIES; CONTRACTOR MUST COORDINATE THE WORK OF ALL TRADES AND INSURE THAT ALL WORK CAN BE COMPLETE AS IT IS THE INTENT OF THE PLANS. 3.— CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INCLUDING SUBCONTRACTOR'S PERMITS, INSPECTIONS AND APPROVALS FROM GOVERNING AGENCIES WITH JURISDICTION OVER THE PROJECT BEFORE BEGINNING WORK. 4•— ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE REQUIREMENTS OF THE UTILITY COMPANIES INCLUDING THE CITY OF DORAL COUNTY PUBLIC WORKS DEPARTMENT, WHOSE SERVICES SHALL BE USED. 5.— ALL MANUFACTURERS SHALL SUBMIT SHOP DRAWINGS TO THE A/E FOR APPROVAL PRIOR TO FABRICATION. 6.— THE A/E WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, AND HE WILL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE INTENT OF THE CONTRACT DOCUMENTS. 7.— ALL MATERIAL AND WORKMANSHIP SHALL MEET THE REQUIREMENTS OF THE APPLICABLE STANDARD SPECIFICATION OF THE AMER►CAN SOCIETY FOR TESTING AND MATERIALS. 8.— THE GENERAL CONTRACTOR MAY SUBSTITUTE EQUIPMENT AND/OR MATERIALS AS LONG AS SUCH CHANGES MEET ALL F.B. CODE REQUIREMENTS ARE EQUAL TO THOSE SPECIFIED ON PLANS AND OBTAINS OWNER'S APPROVAL IN WRITING, 9.— CONTRACTOR SHALL SUBMIT DADE COUNTY PRODUCT CONTROL APPROVAL FOR WINDOWS, ROOFING & WATER PROOFING COMPONENTS AND ALL OTHER PRODUCTS REQUIRING SAID APPROVAL. 10.— WORKMANSHIP: ALL WORK SHALL BE PERFORMED IN A MANNER CONSISTENT WITH THE BEST PRACTICES FOR THE RESPECTIVE TRADES AND QUALITY SPECIFIED. WORK NOT CONSISTENT WITH THE TRADE HIGHEST LEVEL OF WORKMANSHIP WILL BE REJECTED. ANY WORK REJECTED SHALL BE REDONE AT CONTRACTOR'S EXPENSE. CORRECTION OF DEFECTIVE WORK SHALL BE STARTED NOT LATER THAN FIVE DAYS AFTER NOTICE IS GIVEN THE CONTRACTOR, AND SHALL PROCEED WITHOUT DELAY UNTIL WORK IS COMPLETED. 11.— CLEANUP: THE CONTRACTOR AND ALL TRADES SHALL AT ALL TIMES KEEP THE PREMISES CLEAN OF DEBRIS ARISING OUT OF THE WORK AND FREE FROM ACCUMULATIONS OF WASTE MATERIALS OR RUBBISH CAUSED BY HIS OPERATIONS OR OTHER TRADES. THE CONTRACTOR SHALL PROVIDE AT ALL TIMES A TRASH CONTAINER ADEQUATE FOR THIS JOB. THE CONTRACTOR SHALL DELIVER ALL WORK UPON COMPLETION OF THE JOB IN A CLEAN, READY —TO —USE CONDITION. VACANT SPACE (7898) 1136 SF APPROX. / / �5 D\P�oNp,� / now HEAR USA SPACE (7894) / 1184 SF APPROX. / 000' 0000 0000 Loge 17 JERSEY MIKE'S SUBS EXISTING FLOOR PLAN SCALE: 1 /4"=1'-0' ALL FINISHED SURFACES SHALL HAVE PROTECTIVE COVERINGS REMOVED, AND SURFACES CLEANED OF ALL MARKS, STAINS, SOIL, PAINT, OR ADHESIONS OF OTHER MATERIALS AND LEFT IN PERFECT CONDITION. o D j I REVISIONS: No. /DATE: No./DATE: THESE DRAWING & SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MDS ENGINEERING CORP. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO MDS ENGINEERING CORP. IS PROHIBITED. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITION PRIOR TO PROCEEDING WITH WORK. 9 C�: �•� OF 0: o W U 1 O M (--D H—I r- (7) � W � � o W Q CD�Na o I I --I LLJ 11� CD w�Q00--))Q00 C.41) Q o US -�o z 00 � CD N U CL- Q 0 o Q I` z U L1 Q J � > � = i-n 0 O =z 0 Qo Cn ovo z z � CD Q = wCnW=`n Q w CD CE Q � ct °O = z LI (ifL � N � ma � n QQoN01 m 00 W zLLJ='LLO Q r-- N �-j Cn r- JOB No.: DRAWN BY: M.D.S SCALE: AS SHOW DATE: 07-02-2015 SHEET NAME: LOCATION AND EXISTING FLOOR PLAN Aml SHEET 1 OF 7 MDS ENGINEERING CORPORATION 2"X4" 20 GA CAL METAL PARTITION @ 16" O.C. TYPICAL 2"XE BACKING TYP. WOOD BACKING DETAILS N.T.S. SCOPE OF WORK -PROVIDE NEW OFFICE SPACES LAYOUT -NEW 1 HOUR FIRE RATED TENANT SEPARATION -NEW PAINT FOR NEW OFFICE SPACE -NEW ELECTRICAL WORK WIRES, FIXTURES AND PANEL -NEW GRILLES AND A/C DUCT WORK AS PER NEW LAYOUT -NEW BATHROOM AND SINK BUSINESS NOTE: THIS BUSINESS IS TO PROVIDE PROFESSIONAL SERVICES AND SUPPORT FOR PEOPLE WITH HEARING PROBLEMS, INCLUDING HEARING TESTS AND EQUIPMENTS FIRE NOTES 1-REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE THE APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THIS CODE PER NFPA 1:1.14. 2-PLAN SHALL COMPLY WITH THE FLORIDA FIRE PREVENTION CODE (FFPC) 2014 EDITION WITH EDITION, NFPA 1, 2009 EDITION, & STATE STATUTES, 2014 EDITION (ADOPTED REFERENCED PUBLICATIONS FOUND HEREIN) 3-ALL DOORS IN THE MEAN OF EGRESS SHALL BE SINGLE ACTION RELEASE AND SHALL NOT REQUIRE THE USE OF A KEY, TOOL OR SPECIAL KNOWLEDGE TO OPEN FROM EGRESS SIDE. 4-FIRE EXTINGUISHERS SHALL BE MOUNTED NOT TO EXCEED 48" AFF AND SHALL BE CURRENTLY DATED AND TAGGED BY LICENSED FIRE EQUIPMENT COMPANY. 5-ADDI1IONAL EXIT SIGNS AND EMERGENCY LIGHTS MAY BE REQUIRED BY THE FIRE INSPECTOR AT TIME OF THE FIRE FINAL. 6-DUCT DETECTOR'S REMOTE TEST SWITCHES SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION 48" AFF, NFPA 90A 6-4.4.3(1), & (2) 2002 EDITION. THE ACTIVATION OF THE DUCT DETECTOR SHALL SHALL SHUT THE A/C UNIT DOWN IMMEDIATELY, WITHOUT DELAY. 7-THE NUMERICAL ADDRESS/SPACE # WILL BE PROVIDED ON ALL EXTERIOR DOOR WEATHERPROOF AND CONTRASTING COLORS. IF THE ADDRESS IS TO BE PLACED ON A WINDOW THE NUMBER SHALL BE "WHITE", IF THEY ARE TO BE ON A LIGHT COLORED BACKGROUND THEY SHALL BE "BLACK" BARIATRIC SOUND BOOTHS NOTE: THE BARIATRIC AUDIOMETRIC BOOTHS IS A MODULAR STRUCTURE CONSTRUCTED OF UNIQUE ALL -STEEL, ALL -WELDED CONSTRUCTION AS STANDARD. WALL THICKNESS IS 2" WITH 16 GA. EXTERIOR. 22 GA PERFORATED INTERIOR. (SEE PICTURE SB-1 FOR EXAMPLE). AT TIME OF INSPECTION THE CONTRACTOR SHALL SUBMIT TO THE INSPECTOR ALL MANUFACTURER SPECIFICATION IF IS REQUIRED. PICTURE SB-1 EXISTING EXTERIOR WALLS NEW AND EXISTING ONE HOUR1 PARTY NEW SECTION FOR ACCESSIE SERVICE COU DETAIL AS-1 SCALE: 1 /4" = 1'-O" m r�� NEW BATHROOM PLAN �-jj SCALE: Y2"=1'-01 .00 I ACCESSIBLE BATHROOM 18"MIN. LAVATORY BACK WALL X Q o 33" 36" { N 17-19 19"MIN. HAN171CAPPED WATER CLOSET 54"MIN PAPER 42"MIN--�--�� 12"MIN � t 33� 36 19MIN 17-19 SIDE WALL ACCESSIBLE BATHROOM DETAILS NEW AND EXISTING DOORS SCHEDULE MARK SIZE WITH TYPE MATERIAL FRAME REMARKS 1 3'X6'-8" 1-3/4" FLUSH METAL & GLASS METAL EXTERIOR FRONT DOOR (EXIST.) 2 31X6'-8" 1-3/4" FLUSH METAL METAL EXTERIOR REAR DOOR EXIST. 3 31-0"X6'-8" 1-1 /4" FLUSH WOOD WOOD INTERIOR DOOR (NEW) NOTE FIRE RATED DOORS WITH PRODUCT APPROVAL AND SEPARATE PERMIT 2" COPPER PIPE WATER LI FIRE EXTINGUISHE 2.5" / 1 " PVC PIPE CONDL TO ELECTRICAL SERVICE & DMA 145 LF APPR PROPOSED FLOOR PLAN TACTILE EXIT SIGN TACTILE ACCESSIBLE WC SIGN TACTILE SIGN REQUIREMENTS TACTILE SIGN STATING "EXIT" AND COMPLYING WITH ADA STANDARD 2014, SECTION 703. WC ACCESSIBLE SIGN SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HT SHALL BE 60" FF TO BOTTOM HIGHEST BASELINE CHARACTER OF SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" OF SIGN WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE DOOR. FINISH SCHEDULE AREA FLOOR BASEBOARD WALL CEILING OFFICES & HALLWAY CARPET TILE VINYL DRYWALL CEILING PANELS RESTROOMS SHEET VINYL VINYL T)I�1. BOARD PNMHI � Fl�AS RAW BW (FIf) AT 4 CEILING PANELS * NOTES -CONTRACTOR SHALL VERIFY ALL FINISHES W/OWNER PRIOR TO PURCHASING MATERIALS CONTRACTOR SHALL VERIFY ALL COLORS W/ OWNER PRIOR TO COMMENCEMENT OF WORK -THE PUBLIC RESTROOM SHALL BE LINED WITH NONABSORBENT MATERIAL TO A HEIGHT OF 4 ft ABOVE THE FLOOR MIN. IN ACCORDANCE WITH FBC 2014 XTINGUISHER REVISIONS: No./DATE: No./DATE: THESE DRAWING & SPECIFICA11ONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MDS ENGINEERING CORP. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO MDS ENGINEERING CORP. IS PROHIBITED. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITION PRIOR TO PROCEEDING WITH WORK. CO 1 ®: uw ,o 0. p ,�.C-D s'o con o Q U � V O M O t` W 00 © CD Li_ '►� 0 W Q� m � Q O US c w z CD --� 0c) JOB No.: DRAWN BY: M.D.S SCALE: AS SHOW PROPOSED FLOOR PLAN A=2 SHEET 2 OF 7 MDS ENGINEERING CORPORATION REFLECTED CEILING NOTES 1.) RE: MECH. FOR EXACT NUMBER, TYPE AND LOCATION OF SUPPLY, RETURN AND EXHAUST FIXTURES. 2.) RE: ELECT. FOR EXACT NUMBER, TYPE AND LOCATION OF OUTLETS. 3.) CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS. ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS AS INDICATED ON THE ARCHITECTURAL DRAWINGS. 4.) PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO PARTITION SURFACES, FREE FROM CURVES, BREAKS, OR OTHER IRREGULARITIES 5•) LIGHT FIXTURES, EXIT SIGNS AND OTHER CEILING ELEMENTS SHALL BE LOCATED IN CENTER OF INDIVIDUAL CEILING TILE U.O.N. OR AS DIRECTED BY ARCHITECT. 6') PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE VERIFY MANUFACTURER RECOMMENDATIONS. 7.) THE REFLECTED CEILING PLAN INDICATES THE LOCATION OF CEILING TYPES, CEILING FIXTURES, FAN MOTORS, AND ASSOCIATED ITEMS. REFER TO ENGINEERING DRAWINGS (LIGHTING PLAN) FOR CIRCUITING, WIRING LAY -OUT, AND ADDITIONAL INFORMATION. 8.) ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE CEILING ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING, FIRE PROTECTION, ELECTRICAL AND LIGHTING DRAWINGS, BY THE DESIGN ENGINEERS. 9.) CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICTS CEILING FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, ETC., PRIOR TO INSTALLATION. 10.) VERIFY FIELD CONDITIONS AND LOCATION OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ANY AND ALL OTHER APPLICABLE ITEMS. INSTALL NEW PLUMBING, MECHANICAL FANS, DUCTS, CONDUITS, AND OTHER RELATED ITEMS SO AS TO NOT CONFLICT WITH LIGHTS AND ANY UNIQUE FIELD CONDITIONS. 11.) FURNISH AND INSTALL UNDERWRITERS LABORATORY, INC. (U.L.) LABELLED DEVICES THROUGHOUT. 12.) PROVIDE AND INSTALL EMERGENCY LIGHTING PER ADA/ TITLE 24 REQUIREMENTS. 13.) ELECTRICAL CONTRACTOR TO PROVIDE ALL SWITCHES, DIMMERS, & PLATES, AS REQUIRED BY DESIGN, LOCATED 44" A.F.F. 6" FROM DOOR FRAME. U.O.N. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GANGED TOGETHER, AND FURNISHED WITH ONE COVER PLATE. 14,) N.L REFERS TO NIGHT LIGHT. DINING AREA SHOULD HAVE AT LEAST Two LIGHTS THAT OPERATE THROUGH THE EVENING HOURS FOR SAFETY. SUSPENDED CEILING DETAIL PROVIDE MAIN RUNNERS CONTINUOUS IN LINE WITH EACH SIDE OF RECESSED LIGHT AND PARALLEL MAXIMUM 4'-0' ON CENTERS IN THE CEILING FIELD. CROSS RUNNERS SHALL BE MAXIMUM 2'-0" ON CENTERS. PROVIDE ACCESSIBLE HOLD-DOWN CLIPS FOR ACOUSTIC TILES MORE THAN 1 LB./SQ.FT. PROVIDE MINIMUM 12 GAUGE GALVANIZED STEEL HANGER WIRE MAXIMUM 4'-0' ON CENTERS ALONG MAIN RUNNERS. 0 0 0 o O 0 ACOUSTICAL CEILING NOTE EXISTING ACOUSTICAL CEILING 2'X4' TILE AND GRID AT + 9'-11 A.F.F. 3 LL�JJ 2 .e •" 6 O e 4 .Q • ♦,..lj a. td" e SECTION A -A •� •.°�`• TOP FIRE WALL FIRE STOPPING DETAIL N.T.S. 1. EXISTING CONC. DOUBLE TEE. 2. WALL ASSEMBLY: THE 1 OR 2 H FIRE -RATED GYPSUM BOARD /STEEL STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN ACCORDANCE WITH U419 WALL AND PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. (SEE UL CERTIFICATE ATTACHED TO PLANS) 3. FILL, VOID OR CAVITY MATERIAL* - SEALANT - MAX SEPARATION BETWEEN THE BOTTOM OF ROOF AND TOP OF WALL IS 3/4 IN. (19 MM). THE JOINT SYSTEM IS DESIGNED TO ACCOMMODATE A MAX 33 PERCENT COMPRESSION OR EXTENSION FROM ITS INSTALLED WIDTH. FILL MATERIAL INSTALLED ON EACH SIDE OF WALL BETWEEN THE TOP OF THE GYPSUM BOARD AND THE BOTTOM OF THE CONCRETE. MIN 5/8 IN. (16 MM) THICKNESS PLUS A 1 /4 IN. (6 MM) CROWN REQUIRED FOR 1 HR FIRE RATED SYSTEM. MIN 1-1/4 IN. (32 MM) THICKNESS INSTALLED FLUSH WITH SURFACE OF WALL REQUIRED FOR 2 HR FIRE RATED SYSTEM, HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP601S ELASTOMERIC FIRESTOP SEALANT (SEE HITI SPECIFICATION SHEET ATTACHED TO PLANS) L 7894 L HEAR L 7898 USA L L L L \ L L L L L / L / / L / FRONT ELEVATION. SCALE: 1 /4"=1'-O" PROPOSED REFLECTED CEILING PLAN. OTTOM OF ROOF EXIST. TOP OF ROOF .r '�. ` - • '+� f 8' 8' USE MLT STUDS MATCHING WALL II II ROOF TRUSS SEE TOP FIRE WALL FIRE STOPPING DETAIL SLID &GAGE AS LATERAL BRACE BOTTOM IN THIS SHEET. SUPPORT 0 8' MAX. STAGGERED CONNECTED TO CONC. TWIN-T W/ 2"X4" METAL 20 GAUGE CONT. NEW INTERIOR (2) 3/16" X 2" CONC. TAPCON. TOP PLATE CONNECTED TO EXIST. ACOUSTICAL CEILING Z CONCRETE ROOF SLAB W/ 1"X3/16 (4"X2' PANELS) TAPCON @ 16" STAGGERED. PROVIDE NEW ACOUSTICAL ONE PLAY OF 5/8" TYPE "X" GYPSUM ]/ CEILING (2'X4' PANELS) AT DRYWALL AT EACH SIDE AND OF THE WALL 10'-1/2" HIGH SEE FLOOR (SEE ITEM 5 ONE HR RATING IN THE UL REFLECTED CEILING PLAN CERTIFICATE ATTACHED TO PLAN) 22 GAGE 3%" METAL PLATE 2"X4" VERT. METAL STUD ® 16" O.C. CONT. AT TOP OF WALL FABRICATED FROM MIN. 20 MSG(0.0329", MIN. BARE METAL THICKNESS) CONNECTED 1/2" GYPSUM DRYWALL W/ 3/ 8" LONG TYP S-12 STEEL 1 HOUR FIRE WALL SHALL SCREWS ON BOTH SIDE OF THE STUDS TO EXTEND FROM THE TOP OF W DRYWALL SCREW 0 / 2"X4" METAL BASE ON BOTTOM 0 2"X4" CONC. SLAB TO THE 0 4" O.C. ON BOTH SIDE. METAL CONT. AT TOP. UNDERSIDE OF THE ROOF AND SHALL BE BUILT IN cO = 2"X4" 20 GAUGE METAL ACCORDANCE WITH UL 22 GAGE 3%" METAL HORIZONTAL BRACING AT MID DESIGN No. 419 (FOLLOW o = BRACING AT MID HEIGHT HEIGHT CONNECTED W/ ALL INSTRUCTION IN THE UL I C) CONNECTED W/ METAL METAL SCREW. CERTIFICATE ATTACHED TO SCREW. PLANS) J INSULATION R-11 w U \\—TYPICAL VACANT SUIT BAY 1403 22 GAGE 3%" HEAR USA VERT. METAL STUD 16" O.C. GAGE 22 3%" METAL BOTTOM TRACK W/0145 DIA. X 1-1 /4" POWDER DRIVEN FASTENER 0 24" OC PER ICC-ESR 1799 LARR # 2582 2"X4" METAL CONT. BOTTOM PLATE CONNECTED TO EXIST. CONCRETE SLAB W/ 1"X3/1 ---MNYL BASE TAPCON @ 16" STAGGERED. 7. 7771�1 DETAIL P-1 NEW INTERIOR PARTITION SECTION?. DETAIL FW-1 (1 HOUR FIRE RATED PARTY WALL UL DESIGN No.U419) REVISIONS: No./DATE: No./DATE: THESE DRAWING & SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MDS ENGINEERING CORP. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO MDS ENGINEERING CORP. IS PROHIBITED. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITION PRIOR TO PROCEEDING WITH WORK. 41 , cu • 2 � / Q• c .0 0 C:l. t f rII! 0`;�� . • •Q O S r W Q Vcol � V � M O E` 00 W Q CD Z N o f W tz c� < I W Q��00 00 3;: Q O cn m m �� Q 0 � 0-) LLJ z O 00 1-- O N U a - JOB No:. 13-035 DRAWN BY: M.D.S SCALE: AS SHOW ELEVATION, REFLECTED CEILING AND PARTITIONS DETAILS A-3 SHEET 3 OF 7 MDS ENGINEERING CORPORATION ELECTRICAL SPECIFICATIONS. 1. THE ELECTRICAL INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF NEC 2014. A.CLEARANCE NEC 110-26 (2) B.DEDICATED SPACES FOR SWITCHBOARDS AND PANEL BOARDS INCLUDING. 2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE GROUNDING WHICH COMPLIES WIYH THE CODE AND INSPECTION AUTHORITY. 3. THE E.C. SHALL INSTALL ELECTRICAL DEVICES AND EQUIPMENT TO WITHSTAND THE SHORT CIRCUIT CURRENT AVAILABLE THE CURRENT PROTECTIVE DEVICE RATING FOR EQUIPMENT SHALL BE VERIFIED PRIOR TO BID. 4, ALL CIRCUITS TO BE NUMBERED AND IDENTIFIED ON ELECTRICAL PANEL 5. RECEPTACLES AND SWITCH PLATES TYPE & COLOR SHALL BE SELECTED BY OWNER 6. ALL BREAKERS TO BE SIZED ACCORDING TO MAN UFACTURER'SSPECIFICATIONS. 7. ELECTRICAL CONTRACTOR PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING CHECK NAMEPLATE DATA OF ALL EQUIPMENT . APPLIANCES TO OBTAIN CORRECT SIZES AND OVER CURRENT PROTECTION. 8. VERIFY MANUFACTURER'S SPECIFICATIONS AS TO THE EXACT LOCATION OF RECEPTACLES/JUNCTION BOX FOR APPLIANCES AND OTHER EQUIPMENT. 9—THE CONTRACTOR SHALL FURNISHALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE ELECTRICAL :INSTALLATION IN ACCORDANCE WITH THESE DRAWING AND SPECIFICATIONS. 10—THE CONTRACTOR SHALL FURNISH ALL MATERIAL & WORKMANSHIP FREE OF DEFECTS FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. THE GUARANTEE SHALL BE WRITING 1 1—THE CONTRACTOR SHALL OBTAIN ALL NECESSARY BUILDING PERMIT, LICENSES AND INSURANCE FOR WORK UNDER THIS CONTRACT. 12—THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITION. 13—COMPLY WITH THE NATIONAL ELECTRICAL CODE 2008 AND THE FLORIDA BUILDING CODE 2010 (F.B.C.)OR ANY OTHER LOCAL CODE OR REGULATION IN ITS CURRENT EDITION. 14—PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 115—PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE LINES INCLUDING WIRING 16—ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 17—COORDINATE ALL OUTLETS LOCATION WITH BUILDING ARCHITECTURAL FEATURES. 18—ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR_ NOTES: 1.-PROVIDE A DISCONECTIVE MEANS INSTALLED IN ACCESSORY LOCATION FOR SERVICING OR MAINTAINING THE BALLAST OF ALL FLUORESCENT FIXTURES PER NEC 2014 - 410.130 (G) 2.-THIS IS NOT A HEALTH CARE FACILITY 3.-3M FIRE BARRIER SEALENT, CP 25 WB+(UL 1479) & CAN/ULC S115 UP TO 4 HRS AS PER ASTM E 814 4.-COMMERCIAL LIGTHING TO COMPLY WITH FBC ENERGY. I EXHAUST FAN SPECS NEW EF-1 "GREENHECK" MODEL SP 50 CFM ©1/4" WC, 115 VOLTS, 50 WATTS CEILING MOUNTED W/B.D.D. BUILT—IN. IXH UNDER — LAVATORY (E) EXIT 8c EMERGENCY LIGHTS NOTE: EXIT & EMERGENCY LIGHT W/ BATTERY BACKUP TO BE CONNECTED AT HEAD OF SWITCH OF THE CIRCUIT OF THE AREA OF EXIT & EMERGENCY LIGHT. FLUORESCENT LIGHTING SENSORS NOTE. - ALL FLUORESCENT LIGHTING FIXTURES THAT UTILAZE DOUBLE -ENDED LAMP AND CONTAIN BALLAST SHALL BE PROVIDED WITH AN EXTERNAL DISCONNECT MEAN TO BE SERVICE IN PLACE. FLASH PROTECTION NOTE SWITCHBOARDS, PANELBOARDS, INDUSTRIAL CONTROL PANELS, METER SOCKET ENCLOSURES, AND MOTOR CONTROL CENTERS THAT ARE IN ORDER THAN DWELLING OCCUPANCIES AND ARE LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE EQUIPMENT. GROUND —FAULT CIRCUIT INTERRUPTER PROTECTION ALL 125-VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE LOCATION SUCH AS, BATHROOMS, COMERCIAL KITCHENS, ROOF TOPS, OUTDOORS ( HEATING AIR-CONDITIONING AND REFRIGERATION EQUIPMENT OUTLET), SHALL HAVE GROUND -FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL. ELECTRICAL SCOPE OF WORK -EXISTING TENANT SPACE WITH INTERIOR REMODELING, FIXTURES ARE ALL NEW AND WIIL BE INSTALLED ACCORDING NEW LAYOUT. A NEW PANEL IS BEING PROPOSED 200 AMPS PANEL(MLO) AND THERE IS AN EXISTING 200 AMPS SERVICE IN 120/208 30 THAT WILL REMAIN AS IT IS. G\osslf,eOW UK s t e(` I 2 Hour Fire Rated Through Penetration Firestop for Plastic Pipe through Gypsum walls using intumescent devices 3735 Graen Rd. Beachwood, OH, 44122 Drawing not to scale Q 2-Hour Fire Rated gypsum wallboardistud assembly. © Plastic Pipe - 4" dia. (or smaller) sch. 40 PVC pipe for use in closed or vented piping systems, with a nom. annular space of 1/8". (D A) TREMstop WS - wrap strips, tightly wrapped 6 times around pipe. B) TREMstop MCR - steel restricting collar. C) FYRE-SIL - Min. 1/4" thick sealant applied to wall/collar and collar/pipe interfaces. Protect, The products used in die above assembly have The above described assembly and products have been tested anare been tested to accordance with the follo i- : with 8 based on both past and anticipated Location: ASTM E814 (UL1479) Test Netted performance ctitena Tremco shalt for Through Penetration Firestopping, not be liable for arty damages, direct Installer. or consequential, resulting from use Date: 2/26/94 Drawin : 7R—w2083 of this material ar design. Tremco .Signature: be defective. pig Approved by: C. Tuaeo mffishalcriallf and to ELECTRICAL SYMBOL LEGEND ((D JUNCTION BOX '�FILJB W/SPECIAL SUPPORT FAN & LIGHT (o HIGH HATS LIGHTING + MINI HIGH HATS LIGHTING VAPOR PROOF 0 CEILING MOUNTED FIXTURE �- WALL MOUNTED FIXTURE MOTOR FOR CHANDELIER L3 PICTURE WALL MOUNTED FIXTURE FLUORESCENT FIXTURE QUADRUPLEX RECEPTACLE GFI RECEPTACLE GFI RECEPTACLE 8" ABOVE COUNTER e- DEDICATED RECEPTACLE F4 2 POLE OUTLET (9-- RECEPTACLE SMTCHABLE DUPLEX RECEPTACLE (� GARBAGE DISPOSAL C� SPOT LIGHT ELECTRIC PANEL LfJ EXHAUST FAN WP WEATHER PROOF $ SWITCH $3 3WAY SWITCH $D LOW VOLTAGE SYSTEM SWITCH (DIMMER) DATA/TELEPHONE OUTLET 0 TELEVISION CABLE OUTLET so SMOKE DETECTOR GARAGE DOOR OPENER CONTROLLER INTERCOM FD_B1 DOOR BELL WALL FLUORESCENT FIXTURE q_,N EMERGENCY LIGHT. 4_tP, EMERGENCY & EXIT LIGHT. S_ EXIT LIGHT. (E/R) EXISTING RELOCATED (N) NEW (E) EXISTING TYPE: LOADCENTER, NEMA-1 PANEL »A» MAIN BUS: 200 AMPS SERVICE: 1PH, 3 W, S/N. NEUTRAL: 200 AMPS VOLTAGE: 120/240 V (NEW) MAIN : M.L.O MOUNTING: SURFACE AIC: 22,000 °- cn W _J o-Z M. CD oww z N N m in REMARKS o z ,- v z Y c� REMARKS ww N v, N z N � o� ¢ � � cn 30 3 7,500 3/4 8 RTU #1(E) 1 2 I.W.H 12 1/2" 4200 1 20 3 5 4 6 RECEPTACLES 12 1/2" 1080 1 20 20 1 1 1260 1/2" 12 RECEPTACLES 7 8 RECEPTACLES 12 1/2" 720 1 20 20 1 1 900 1/2" 12 RECEPTACLES 9 10 WATER DISPENSER 12 1 2" 200 1 20 20 1 1200 1/2" 12 LIGHTING 11 12 SPACE 20 1 700 1/2" 12 LIGHTING 13 14 20 1 1200 1/2' 12 SIGN 15 16 20 1 180 1/2' 12 GFCI BATH 17 18 SPACE 19 20 21 22 23 24 25 26 27 28 29 30 31 32 34 36 38 40 42 33 35 37 39 41 TOTAL CONNECTED LOAD: FEEDER: SEE RISER CON11NUOUS LOAD (LIGHTING): = 3,100 VA 25% OF CONT LOAD = 775 VA NON. CANT LOAD = 16,040 VA TOTAL DEMAND LOAD: _ 19,915 VA FED FROM: SEE RISER AT 208 / 3 / 60 = 55.32 AMPS - THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT NAME PLATE RATING OF ALL EQUIPMENT BEFORE INSTALLATION & INFORM TO THE ELECTRICAL ENGINEER OF ANY DISCREPANCIES. VACANT SPACE (7898) 1136 SF APPROX. A6 A9PA9 A&V WTA 9 2' A87 A8 A8 A TEST A13 BOOTH A9 A13 A7 A7 A11 A7 A7 A7 A11 ° A9 Al Al 1 -- -- i A13 A9 A13 TEST Al �7=A6 A11 BOOTH Al -' NEW ELECTRICAL A6 A6 l -- PANEL -G t- \ Al 3 5 ` I X'I I I \ O A13 Al Al I \--'� L i i Al Al A11 Al i-----1---J JERSEY MIKES SUBS ELECTRICAL PLANS, NOTES AND RISER SCALE: 1 /4"=V-O" J A15 SIGN CKT VIA TIME CLOCK - ALL CB USED FOR , A/C & REFRIGERATION UNITS SHALL BE HACR U.L. LISTED. NON -CONCURRENT LOAD PROVIDE PERMANENT PLAQUE IN ELECTRICAL ROOM FOR ARC FAULT & SHOCK HAZARD: rWARNINGsh and Shock Hazard iate PPE Required PPE: PERSONAL PROTECTIVE EQUIPMENT NEW RISER DIAGRAM TO REMAIN 200 AMP ELECTRICAL 4" 120/208 V 30 4W T SPACE 7894 PROVIDE PERMANENT PLAQUE IN ELECTRICAL ROOM FOR ARC FAULT & SHOCK HAZARD: I WARNING Arc Flash and Shock Hazard Appropriate PPE Required PPE PERSONAL PROTECTIVE EQUIPMENT REVISIONS: No,/DATE: No./DATE: THESE DRAWING & SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MDS ENGINEERING CORP. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO MDS ENGINEERING CORP. IS PROHIBITED. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITION PRIOR TO PROCEEDING WITH WORK. 0' pit, ••.... 5� U CD CD �N a L. J ry t0 o L7�QIJ d- Z U 0 c0 00 �/1 Q p US ry Q 0 r o z a � 00 N U n JOB No.: DRAWN BY: M.D.S SCALE: AS SHOW SHUT NWE: ELECTRICAL PLAN Emil SHEET 4 OF 7 MDS ENGINEERING CORPORATION 11 1 141.IFIl7�'�]Fna»Ilail El GENERAL H.V.A.C. NOTES 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawings. The Florida Building Code 2010 and the latest edition of the following publications: (o)ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 (c) SMACNA (d) ASHRAE. 2. All air conditioning ductwork shall be 1 1/2 " standard duty foil reinforced fiberglass (R-6) manufactured logo printed on the vapor barrier. 3. All exhaust ductwork shall be code gage galvanized sheet metal. 4. Duct size shown are net free area inside. 5. All air devices (diffusers, registers and grilles) shall be all aluminum construction, with exposed surface chemically treated to receive paint to match color or AIRGUIDE or approved equal. 6. Provide opposed blade dampers at all diffusers and registers. 7. Thermostats shall be combination cooling/heating with system Cool/Auto/Heat/Off and Fan On/Auto selector switches. 8. Refrigerant piping shall be copper type I" with 3/4" armaflex. Insulation shall be provided for suction lines. 9. Provide new filters for fan coil before starting. These filters must also be replaced prior to final acceptance by owner. �3 4" DEEP x 118 WERED ACTUATED, PINS. FLEX . DUCT. UP TO 29 ROOF STRUCTURE 4-16d NAILS THRU PLYWOOD DUCT FROM UNIT --- VO 4'" DEEP x 118" WERED ACTUATED, PINS. 1-1/2"WIDE x 26 GA G. M. STRIP AT SUPPORT. DUCT HANG DETAIL PROVIDE W/P. CAP LOW PROFILE B.D.D. AT TOP FOR DRYER. NO SCREEN FOR BATHROOM PROVIDE INSECT SCREEN TYPICAL ROOF CAP DETAIL L O.A.I. AND/OR TOILET EXH. NTS N. T. S FIELD COORDINATION NOTE EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE-FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ ENGINEERS IF ANY CONFLICT OCCUR PRIOR ITS INSTALATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. SCOPE OF WORK. THIS JOB CONSIST OF INTERIOR REMODELING FOR EXISTING TENANT SPACE. HEAT LOAD CALCULATION HAVE BEEN DONE BECAUSE A NEW LAYOUT, THE EXISTING 3 TONS RTU WILL BE USED (SEE SCHEDULE). NEW A/C DESIGN HAVE BEEN DONE AS APPEAR ON DWG. RIGID QUCT UP TO 29 WITH OR 16 " DEEP. 1-1i 1-112" WIDTH x 26 GA STRAP @ 8 "- 0 0/C LOW VELOCITY SUPPLY AIR DUCT (SEE PLAN VIEW) E0* METAL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY INSULATED FLEX. (8'-0" MAXIMUM) (THERMOFIN PROVIDE 1" FIBERGLASS OR EQUAL) INSULATION SEALED TO TO NECK & PERIMETER OF DIFFUSER PERFORATED SEAL JOINT W/ DIFFUSER DUCT S k& TAPEEALER FLEXIBLE DUCT CONNECTION DETAIL N.T.S. ROOFTOP AIR CONDITIONING UNIT SCHEDULE. MARK NO. NEW RTU-1 MODEL 7SC036A3E0A0A TOTAL COOLING CAPACITY BTUH 36,000 SENSIBLE COOLING CAPACITY BTUH 23,500 SUPPLY AIR CFM 1,200 ENTERING AIR TEMP. (DB/WB) 80/67 OUTDOOR DESIGN TEMP. (DB) 95 EXTERNAL STATIC PRESS. I N. W. G. 0.7 ELECTRIC SERVICE 2081230130 HEATING KW (BTUH) 7.5 FUSE SIZE 30 AMPS SEER 10.7 DESIGN MFG. TRANS EXHAUST FAN SPECS I NEW EF-1 "GREENHECK" MODEL SP 50 CFM @1/4" WC, 115 VOLTS, 50 WATTS CEILING MOUNTED W/B.D.D. BUILT-IN. OUTSIDE AIR INTAKE CALCULATIONS AS PER FBC 2010 & ASHRAE-62-1997. O. A. I= # OF PERSON X CFM/PERSON + SQ. FT X CFM/SQ. FT OFFICE AREA= 12 PERS X 7.0 CFM/PERS + 597 SF X 0.12 CFM/SQ.FT = 156 CFM RECEPTION AREA= 10 PERS X 5 CFM/PERS +314 SF X 0.06 CFM/SQ.FT = 69 CFM HALLWAY= 237 SF X 0.06 CFM/SQ.FT = 15 CFM TOTAL O.A.1 CALCULATION = 240 CFM 400 CFM WILL BE PROVIDED 7An !`CAA RTU #1 - - - = 20.0 1200 CFM HVAC DESIGN REQUIRE: YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(S) X SMOKE DAMPERS X FIRE RATE ENCLOSURE X FIRE RATED ROOF/FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X VACANT SPACE (7898) 1136 SF APPROX. PS-1 PS-1 PS -1 PS TEST 150 CFM () 150 CFM PS-1 CFM BOOTH (N) 225 CFM (N) 6"0 (N) n 8 TEST 8"0 PS-1 81)0 BOOTH 100 CFM OX10 RAC OX10 RAG (N) 6„0 AM V.D V.D V.D V.D V.D PS-1 ° 8"X8" 1031X10" 12"X10" 10"X10" 225 CFM I 1 PS-1 V.D 50 CFM PS-1 V.D �_,� -- V.D 100 CFM I PS_1 V.D (N) L� (N) 4„0 �X� , (N) 6 I ► t 6 „ 100 CFM 8 0 O PR, 1 (N) 24 X24„ ---�--� JERSEY MIKE'S SUBS MECHANICAL P LAN S, NOTES AND DETAILS SCALE: 1 /4"=l'-O" CHANNEL SECTION If Total Minimum Minimum Extension is Channel Channel not greater than: Gauge Profile 6" 24 3" X 1.5" 18" 22 3" X 2" 30" 18 3" X 2" USE OF 2" WIDE 22 gauge 2'x 1.5" hangers may be substituted for 3" hangers for ducts with widths not over 48" and depths not over 24" provided that not more than one joint occurs between hangers and the maximum hanger spacing 4ft. Exception: When duct perimeter is 80" or less and does not require reinforcement two joints are permitted between hangers 5 STANDARD 3" WIDE HANGERS Hanget extension to be the sum of the distances between the hanging wires and the duct size, ID (Smacna) Duct size, Inches Maximum Hanger Spacing 48: Wide or grater 4 ft Less tho 48" wide Eft and less than 48" deep Width between 28" 6ft & 48" and greater than 16" deep Less than 29" wide 8ft and 16 depth or less HANGERS AND SUPPORTS N. T. S. MECHANICAL SYMBOL LEGEND DENOTE 24X24 PS-1 DENOTE RETURN AIR GRILL 24X24 PR-1 5 REVISIONS: No./DATE: No./DATE: THESE DRAWING & SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MDS ENGINEERING CORP. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO MDS ENGINEERING CORP. IS PROHIBITED. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITION PRIOR TO PROCEEDING WITH WORK. —%®4 a l O • c) • "' 111 �' ••• ••c�� .A ' •• • % A 4� I� O Q U � o o Wow Q CD�Na Z W v Q��00 00 Q m ►-� Q� a-) � z 0 DO CO ;1.4 N U 11 F I JOB No.: DRAWN BY: M.D.S SCALE: AS SHOW MECHANICAL PLAN mmi SHEET 5 OF 7 MDS ENGINEERING CORPORATION I FIELD COORDINATION NOTE EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE-FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ ENGINEERS IF ANY CONFLICT OCCUR PRIOR ITS INSTALATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. SCOPE OF WORK: THIS JOB CONSIST OF INTERIOR REMODELING FOR AN EXISTING TENANT SPACE. A NEW BATH AND A NEW SINK ARE BEING PROVIDED.. 2"4 AIR ADM�TANCE VALVE NEW I.W.H (POINT OF USE UNDER LAV.) EXISTING SEWER LINE �_ - - - - - \ 3" O(7FU: SPECS IN COMPLIANCE W/F.B.0 : SHALL BE "TITAN-SCR2 N-42" ELECTRONIC TANKLESS WATER HEATER. TI�gN, MODEL: N-42, 4.2 KW, 240V / I- / 60 Hz, 20 AMPS WEIGHT: 8 POUNDS C'`42 c� COMPLIANCE: UL #499 STANDARD: ANSI-Z, 10.03 TESTED: APPLIED RESEARCH LAB29-580 MIAMI-DADE NOA f 97-0627.16 DIMENSIONS 7" W X 10" H X 2-3/4 D ENERGY EFFICIENCY: UP TO 97 % * NO R.V.D OR OVER FLOW REQUIRED AS PER MANUFACTURER SPECS. INSTANT WATER HEATER DETAIL N.T.S. 3" O(YU) VACANT SPACE (7898) 1136 SF APPROX. jL�2-0(2`F'U') TEST BOOTH EXISTING 2" 0 C.W SERVICE. i TEST I I BOOTH i 2 1-1 /2" 0(1 FU) s LAV. 2"0(1 FU) O � 0 wC " 4FU JERSEY MIKE'S SUBS PLUMBING FLOOR PLAN SCALE: 1 /4"=1'-0" REVISIONS: No. /DATE: No./DATE: THESE DRAWING & SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MDS ENGINEERING CORP. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO MDS ENGINEERING CORP. IS PROHIBITED. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITION PRIOR TO PROCEEDING WITH WORK. It �.w o�c .zo Ck d•.• Q U L� c 4 M CD ono W Q CD ►-.� �., w CD ZQ Z Q rn >- 00 00 V1 Q O u� O � J L�J o z N U a_ JOB No.: DRAWN BY: M.D.S SCALE: AS SHOW DATE: 10-26-2013 SHEET NAML: PLUMBING PLAN p=1 SHEET 6 OF 7 MDS FNGINFFRING CORPORATION GENERAL PLUMBING NOTES 1. ALL WORK SHALL CONFORM WITH FLORIDA BUILDING CODE 2014 EDITION (F.B.C.2014), FEDERAL ORDINANCES GOVERNING THE INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT/ENGINEER. BEFORE SUBMITTING A BID. THE ARCHITECT/ENGINEER. WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED. 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK . 3. EXAMINE ALL DRAWMNGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND/OR CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING, ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. IF DISCREPANCIES , CONFLICTS , INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRACTOR. 5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES. 6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO N.T,S PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, RULES OR ORDINANCES. 7. PROVIDE MEANS "FURNISH AND INSTALL". 8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. 9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVABY PROPER AUTHORITIES. 10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS. 11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED TO THE OWNER. 12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE 13. PROVIDE BATHROOM FIXTURES AS SPECIFIED OR AS SELECTED BY OWNER AND TO COMPLY W/F.B.C.2014 SPECIALLY CHAPTER 11. 14. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE. 15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS. 17. ALL SANITARY FITTINGS SHALL BE DIRECTIONAL TYPE. 18. MATERIALS A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE TYPE "L" COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE GROUND. B. COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT COPPER INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB. C. SANITARY WASTE AND VENT 4"0 AND SMALLER SHALL BE P,V.C.,SCHEDULE 40 S. STORM LINES INSIDE BUILDING SHALL BE P.V.C. SCHEDULE 40 E. IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF BUILDING SHALL BE SCHEDULE 40, PVC. F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE AND FITTINGS. G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPER, MIN. 3/4" DIA. �UppR) d( MAXIMUM FLOW RATE AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS PLUMBING FIXTURE OR FIXTURE FITTING MAXIMUM FLOW RATE OR QUANTITY LAVATORY, PRIVATE 1.0 GPM @ 60 PSI LA VA TOR Y, PUBLJC 0. 5 GPM @ 60 PSI LAVATORY, PUBLIC, METERING OR SELF -CLOSING 0.25 GALLONS PER METERING CYCLE SHOWER HEAD 1.5 GPM @ 80 PSI SINK FAUCET 1.0 GPM @ 60 PSI URINAL 0.5 GALLON PER FLUSHING CYCLE WATER CLOSET 1.28 GALLON PER FLUSHING CYCLE NOTE: (R) RELOCATE (E) EXISTING (N) NEW (E/R) EXISTING RELOCATE N.T.S HAMMER ARRESTOR: - AMTROL, MODEL 500 - INSTALL IN ACC. LOCATION. - CONNECTION TION SIDE 1/2" NPT - DIAMETER: 3-3/8" MAX. PRESSURE: 150 PSI MAX. TEMP: 200' F MAX. SHOCK PRESSURE. 200 PSI NOTE: ALL SANITARY PIPE 2 1/2"0 OR SMALLER SHALL RUN @ 1/4" SLOPE PER L.FT. 3" AND LARGER @ 1/8" SLOPE PER L. FT. PLUMBING RISERS & NOTES SCALE: 1 /4"=1'-0" WATER PIPING SIZE-2 Q 1/2"0 CW/HW © 1/2„0 CW d 3�4"O CW/HW"0 HW ® 1/2"0 HW Q 3/4 "0 CWS (Z) 1 "o CWS ® 3/4 "0 HWS ® 1 "0 CWS/1/2"O HWS 1@0 1-1/4"0 CWS 11 1 "0 CWS/1 /2"O HWS 1-1/4"0 CW,1/2"O HW Q 2"0 CW Pvp) REVISIONS: No./DATE: No./DATE: THESE DRAWING & SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MDS ENGINEERING CORP. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO MDS ENGINEERING CORP. IS PROHIBITED. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITION PRIOR TO PROCEEDING WITH WORK. 1117 ot`�- , • W w �' a a�'i'• ��`' � r O � M O � CO o W W Q CD N 2) 1 LL QD Q 00 o cCy) �Q 3: m'� 0-) � z 0 0 op 1­— O CV U a_ JOB No.: DRAWN BY: M.D.S SCALE: AS SHOW PLUMBING RISERS AND NOTES P=2 SHEET 7 OF 7 MDS FNI;INFFRIN(; (ORPORATION E .m'� �i�l L:-='la-. r owl ,I ,.. _. .___. _.... -._ .,-. .._ _. .—�`�—'---" — ..- :��IIG �Itl IIdu III�L WiI--' 6Ih Ilkii iJtNL�i'IP.fl LL4i1 Y.I I°L4�IIilYF�l3Yli�� '" m. MI �•�