Loading...
HomeMy WebLinkAbout7050 Gall Blvd (120)r 11. SITE FLORIDA HOSPITAL 7050 GALL BOULEVARD ZEPHYRHILLS, FLORIDA 33541 OWNER FLORIDA HOSPITAL 7050 GALL BOULEVARD ZEPHYRHILLS, FLORIDA 33541 ELECTRICAL CONTRACTOR SN ca APG ELECTRIC, INC. 4825 140TH AVENUE N. SUITE K £I CLEARWATER, FLORIDA 33762 U_ 34 N ifs N_ CO O N N N 0 w z J ML ly"7 Safer. Smarter. SALES REPRESENTATIVE Frank Reinhart 813-313-1652 freinhart@simplexgrinnell.com FLORIDA HOSPITAL - ZEPHYRHILLS FIRE ALARM SYSTEM CONSUL TING ENGINEER TLC ENGINEERING 255 S. ORANGE AVENUE, SUITE 1600 ORLANDO, FLORIDA 32801 DELEGATED ENGINEER OF RECOED CURTIS ENGINEERING SERVICES, LLC 29775 BAYHEAD ROAD DADE CITY, FLORIDA 33523 mp/exGrinne// CO, TM TY PROJECT MANAGER Tom Akos 813-313-1617 takos@simplexgrinnell.com SALES ENGINEER Jay Phoun 813-753-8241 jphoun@simplexgrinnell.com 10500 UNIVERSITY CENTER DR., SUITE 275 TAMPA, FL 33610 PHONE: 813-626-5482 SERVICE: 813-626-5482 FAX: 813-971-8780 DR,4 WINGS PREPARED BY Bob Knickle 813-337-4963 roknickle@simplexgrinnell.com I Sheet List Table I Sheet Number Sheet Title General Information (FA-000 Series) FA-001 COVER SHEET FA-002 GENERAL INFORMATION Floorplans (FA-100 Series) FA-101 FLOOR PLAN - FIRST FLOOR FA-102 FLOOR PLAN - SECOND FLOOR (PHASE 1) FA.-103 FLOOR PLAN - SECOND FLOOR (PHASE 2) Risers (FA-200 Series) FA-201 RISER DIAGRAM Calculations (FA-600 Series) FA-601 CALCULATIONS Wiring Details (FA-700 Series) FA-701 WIRING TYPICALS FA-702 WIRING TYPICALS FA-703 WIRING TYPICALS FA-704 WIRING TYPICALS 'i> o f Z�P�N�R �N �Xp,M p CURTIS ENGINEERING SERVICE, LLC - CA#31561 JAMES M. CURTIS, P.E. - PE#37912 29775 BAYHEAD ROAD DADE CITY, FLORIDA 33523 DEL EGA TED ENGINEER OF RECORD Digitally signed 00""'l/N by James Curtis ���;�'�'c`"+�''•''�'�= No.3 Date:OF 2016.07.22�.�ioa�o*. '09:24:49 -04'00 N N O co co � OO � O M C'7 � O N W W Z F— 0 jZ 1� Z N W co o N EU c-, rr^^ vJ � V Z W LLI �QU 4� N LULU �-'Hco L 3 z O QU) O Z = w� 010. = W � N r ' O —' Q C45 �-- Z� O cn Cn 7 z Q � X w� O 0 J w LL. z 0 a U U w 0 Y U 0 U L0 CM M � Q Qwo J LJL cn 0 J Om J Q J = 26� wo = LLL o� N DRAWN BY: B. KNICKLE CHECKED BY: F. REINHART ISSUE DATE: 17/19/16 292415807 PROJECT #: 292:993523001 SIMPLEXGRINNELL © 2016 SYSTEM: FIRE ALARM SYSTEM SHEET: COVER SHEET FA-001 N d o� T WLD c 'v E2 'y N w _M �n m 0 w E W U O z m E ¢2 o a € �t M. w J Y U_ z Y O m 0 w Q cn H U) p I M lt') N O N N N W H z a cn p GENERAL NOTES SYSTEM DESCRIPTION / SCOPE OF WORK SYMBOL KEY OCCUPANCY TYPE: 1-2 INSTITUTIONAL GROUP 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. SPRINKLER PROTECTION: BUILDING IS FULLY SPRINKLED 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT PROVIDE AND INSTALL A NEW AUTOMATIC AND MANUAL FIRE ALARM SYSTEM AS SHOWN ON DRAWINGS. TO IMPAIR THE CONSTRUCTION SCHEDULE. 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING ALL WIRING TO BE CLASS B. WIRING IS STYLE Y FOR NOTIFICATION APPLIANCE CIRCUITS, STYLE B FOR INITIATING DEVICE CIRCUITS, AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AND STYLE 4 FOR SIGNALING LINE CIRCUITS. AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR AUTOMATIC FIRE ALARM SYSTEM SHALL TRANSMIT THE ALARM, SUPERVISORY AND TROUBLE SIGNALS TO AN APPROVED SUPERVISING INSTALLATION. STATION. THE SUPERVISING STATION SHALL BE LISTED AS EITHER UUFX OR UUJS UNDERWRITERS LABORATORY OR SHALL MEET THE 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A REQUIREMENTS OF FACTORY MUTUAL RESEARCH APPROVAL STANDARD 3011. SUPERVISION OF SYSTEM AND LEASED TELEPHONE LINES BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK -ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE SHALL BE ARRANGED BY THE OWNER. ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. 6. UPDATE THE AS -BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS -BUILT DRAWING SET TO SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON -POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC. FIRE ALARM APPLICABLE CODES & STANDARDS 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON -POWER LIMITED WIRE. 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FLORIDA FIRE PREVENTION CODE, 5th EDITION (2014) FPLP. 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED LIFE SAFETY CODE (NFPA 101, 2012 EDITION) IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. NATIONAL FIRE ALARM CODE (NFPA 72), 2010 EDITION 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. FLORIDA BUILDING CODE, 2014 EDITION 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. NATIONAL ELECTRICAL CODE (NEC, NFPA 70), 2011 EDITION 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22. MAINTAIN 40 PERCENT MAXIMUM CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. WIRE SCHEDULE ABBREVIATIONS LEGEND AC = ABOVE CEILING HT = HEIGHT C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING FIRE ALARM WIRE LIST CIRCUIT DESCRIPTION RISER RATED: FPLR SINGLE CONDUCTOR(THHN,TFFN) PLENUM RATED: FPLP D DOOR HOLDER CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE 2 CONDUCTOR TWISTED AREA=0.0380 SO. INCH AREA=0.0333 SQ. INCH PAIR 14 AWG SOLID ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER FA-1402C-1-1N-03-BX :AREA=0.0097 SO. INCH (EACH): FA-1 402C-1 -2N-03 K REMOTE TEST SWITCH/ SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE LED CIRCUIT - (2) 2 AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH CONDUCTOR 14 AWG ANIXTER PART NUMBER :(4) #14 AWG : ANIXTER PART NUMBER SOLID FA-1402C-1-1N-03-BX :AREA=0.0097 SQ. INCH (EACH): FA-1402C-1-2N-03 M MAPNET/IDNET CIRCUIT SG ANIX./PAIGE 740215 SG ANIX./PAIGE 740214L 1 PAIR 18 AWG TWISTED AREA=O. 196 SQ. INCH AREA=0.0196 SQ. INCH OVERALL SHIELD ANIXTER PART NUMBER ANIXTER PART NUMBER T740215 FAMC-1802C-1-2S-03135 P POWER CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE 2 CONDUCTOR AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH 14 AWG SOLID (SUBSCRIPT: ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER "r' IF RESETTABLE) FA-1402C-1-1N-03-BX :AREA=0.0097 SQ. INCH (EACH): FA-1 402C-1 -2N-03 R RELAY CIRCUIT SG ANIX./PAIGE 454718ARE: SG ANIX./PAIGE 454719ARE 2 CONDUCTOR AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH 14 AWG SOLID ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER FA-1402C-1-1N-03-BX :AREA=0.0097 SQ. INCH (EACH): FA-1 402C- 1 -2N-03 S AUDIO CIRCUIT SG ANIX./PAIGE 454722ARE SG ANIX./PAIGE 454717ARE AREA=0.0204 SQ. INCH 1 PAIR 18 AWG TWISTED AREA=0.0165 SO. INCH OVERALL SHIELD ANIXTER PART NUMBER ANIXTER PART NUMBER FA-1802C-1-1S-03-BX FA-1802C-1-2S-03-BX V VISUAL/SIGNAL CIRCUIT SG ANIX./PAIGE 454718ARE: SG ANIX./PAIGE 454719ARE 2 CONDUCTOR 14 AWG AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH SOLID ANIXTER PART NUMBER : (2) #14 AWG ANIXTER PART NUMBER FA-1402C-1-1N-03-BX :AREA=0.0097 SO. INCH (EACH): FA-1402C-1-2N-03 CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH * 3/4" 0.21 SQ INCH * 1-1/2" 0.82 SQ INCH * 1 " 0.34 SQ INCH * 2" 1.34 SQ INCH * * 40% FILL PER N.E.C. THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. REFERENCE https://www.anixter.com/customer/tycofs FOR SG ANIXTER CABLE DATA E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM RL = RELOCATED DEVICE N/A = NOT APPLICABLE RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER NDU = NETWORK DISPLAY UNIT WP = WEATHERPROOF NEC = NATIONAL ELECTRICAL CODE XP = EXPLOSION PROOF NFPA = NATIONAL FIRE PROTECTION ASSOCIATION H = HIGH HUMIDITY NIC = NOT IN CONTRACT AFF = ABOVE FINISHED FLOOR NPU = NETWORK PROCESSING UNIT AHJ = AUTHORITY HAVING JURISDICTION NTS = NOT TO SCALE ALM = ALARM PAP = PRE -ACTION PANEL ANN = ANNUNCIATOR SCC = STATUS COMMAND CENTER BMS = BUILDING MANAGEMENT SYSTEM SLC = SIGNALING LINE CIRCUIT CBC = CALIFORNIA BUILDING CODE SMK = SMOKE CD = (eg. 15CD) CANDELA SUPV = SUPERVISORY FIRE ALARM SYMBOLS LEGEND SYMBOL DESCRIPTION MODEL# COMMONLY USED BACKBOX, REFER TO DATA SHEET FOR OTHER OPTIONS XPDR FIRE ALARM TRANSPONDER PANEL SIMPLEX 4100-9601 SUPPLIED BY SIMPLEXGRINNELL W / 25AH BATTERY SET SIMPLEX 2081-9287 (REFER TO MOUNTING DETAIL FOR SPECIFIC DIMENSIONS) NAC EXTENDER PANEL F_NA_C_j # DESIGNATES THE NAC PANEL NUMBER SIMPLEX 4009-9201 SUPPLIED BY SIMPLEXGRINNELL W / 6.2AH BATTERY SET SIMPLEX 2081-9272 �F MANUAL PULL STATION, ADDRESSABLE SIMPLEX 4099-9004 SINGLE GANG BOX 2 1/2" DEEP SMOKE SENSOR / BASE SIMPLEX 4098-9714 0 SIMPLEX 4098-9792 BASE 4. OCTAGONAL BOX 1 1/2" DEEP HEAT SENSOR / BASE SIMPLEX 4098-9733 SIMPLEX 4098-9792 BASE 4- OCTAGONAL BOX 1 1/2" DEEP DUCT SMOKE SENSOR SIMPLEX 4098-9756 MOUNT TO DUCTWORK OP ENCAPSULATED RELAY SIMPLEX 4098-9843 SINGLE GANG BOX 2 1/8" DEEP W/COVER (APOLLO AMERICA INC PAM-SD) ❑X REMOTE TEST STATION W/ LED AND KEY SWITCH SIMPLEX 2098-9806 SINGLE GANG BOX 2 1/2" DEEP O INDIVIDUAL ADDRESSABLE MODULE SIMPLEX 4090-9001 SINGLE GANG BOX 2 1/2- DEEP WITH COVER RELAY IAM SIMPLEX 4090-9002 4" SQUARE BOX 2 1/8" DEEP W/TWO GANG COVER ® TRACK MOUNTED SINGLE RELAY SPDT W/ ENCLOSURE SIMPLEX 2088-9008 SUPPLIED W/ ENCLOSURE (APOLLO AMERICA INC MR-101/C) WALL MOUNT MULTI -CANDELA STROBE ONLY RED SIMPLEX 4906-9101 4" SQUARE BOX 1 1/2" DEEP # =CANDELA RATING W/4905-9937 ADAPTER SKIRT WHEN SURFACE MOUNTED WALL MOUNT MULTI -CANDELA SPEAKER/STROBE RED SIMPLEX 4906-9151 4" SQUARE BOX 1 1/2" DEEP W/ 1 1/2" EXTENSION RING # =CANDELA RATING, #W = SPEAKER TAP **USE 70 VOLT TAP** W/4905-9946 ADAPTER SKIRT WHEN SURFACE MOUNTED CEILING MOUNT MULTI -CANDELA SPEAKER/STROBE WHITE SIMPLEX 4906-9154 4" SQUARE BOX 1 1/2" DEEP W/ 1 1/2" EXTENSION RING C # =CANDELA RATING, #W = SPEAKER TAP **USE 70 VOLT TAP** Q DOOR HOLDER RSG/AAMES DH24120FPC SINGLE GANG BOX 2" DEEP Q2 �- SMOKE DAMPER SUPPLIED BY OTHERS SUPPLIED BY OTHERS FS-S-pl SURGE SUPPRESSOR DITEK DTK-120HW SEE DATA SHEET JB JUNCTION/PULL BOX SUPPLIED BY OTHERS SUPPLIED BY OTHERS END -OF -LINE RESISTOR 3.3K (EOL) SIMPLEX 4081-9002 Aw END -OF -LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 END -OF -LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 END -OF -LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 CSFM = CALIFORNIA STATE FIRE MARSHAL TAC = TRUEALERT ADDRESSABLE CONTROLLER DET = DETECTOR TRBL = TROUBLE DGP = DATA GATHERING PANEL TS = TAMPER SWITCH EOL = END OF LINE TYP = TYPICAL EPO = EMERGENCY POWER OFF UON = UNLESS OTHERWISE NOTED FACP = FIRE ALARM CONTROL PANEL VCC = VOICE COMMAND CENTER FATC = FIRE ALARM TERMINAL CABINET VT = VALVE TAMPER FBO = FURNISHED BY OTHERS WF = WATER FLOW FCC = FIRE COMMAND CENTER W = (eg. 1/2W) WATT FAA = FIRE ALARM ANNUNCIATOR W/ = WITH FTR = FIRE ALARM TRANSPONDER W/O = WITH OUT FSD = FIRE SMOKE DAMPER DEVICE ADDRESSING LEGEND SEQUENCE OF OPERATION CONTROL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL ADDRESSABLE CARD (IDNEr OR MAPNE) J DEVICE ADDRESS �Q c,�Q��QN p�y�`�y���,�P\o�Pp� P�o��o� M 2 -1 Gj o� �O o� �� o� �� Q�P Jp�O \��0� ADDRESSABLE DEVICES NUMBERING<11 SYSTEM INPUTS A B C I D I E FIG]HIIIJIKILIMI N 1 0 1 P I Q I R I S I T I U I V I W I X I Yj Z I AA_LABj AC I AD I AE I AF I AG I AH I Al I AJ REMARKS SPEAKER CIRCUIT r DEVICE DESIGNATOR S2-11 SPEAKER DEVICE CIRCUIT DESIGNATOR V=VISUAL OR A/V, H=AUDIBLE ONLY) r DEVICE DESIGNATOR V2-1 VISUAL, AUDIBLE OR A/V DEVICE SMOKE1• 1 1• ©MANUAL PULL STATION00----000-00-------------�----------© ©HEAT SENSOR/DETECTOR 0 1 1 • 1 1- © MAIN FLR. ELEV. LOBBY1 DETECTOR 1 • 1:: 1 1 1 • 00����000�00���0�0�0������������00��� 0 1 • MECH. • 11 DETECTOR 0 1- ROOM DETECTOR M­ELEvAToR SHAFT HEAT DETECTOR m ELEVATOR SHAFT SMOKEDETECTOR MELEVATOR POWER 1 1' M-FIRE ALARM AC POWERFAILUREM FIRE ALARM SYSTEM LOW BATTERY M OPEN CIRCUIT OR GROUND FAULT IN CLASS B NOTIFICATION CIRCUIT (NAC) - SHORT In mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm m mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm m mmmmmmmmmmmmmmmmmmmmmMMMMMMMMMMMMMMMm ® mmmmmmmmmmmmmmmmmmmmmMMMMMMMMMMMMMMM® ® ------------------------------------m No ------------------------------------® m mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm ® ------------------------------------® ® ------------------------------------m ® ------------------�mmmmm------mmmmmm ®• ------------------------------------m ® ------------------------------------® 0 ------------------------------------o ® mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm® ® ------------------------------------E AIBICIDIEIFIGIHI I IJI-KI-L W N I I P I Q-1- RYS-1 T I U I V I W I X I Y I Z I AA I AB I AC I AD I AE I AF I AG LAH AI AJ CURTIS ENGINEERING SERVICE, LLC - CA#31 61 JAMES M. CURTIS, P.E. - PE#37912 29775 BAYHEAD ROAD DADE CITY, FLORIDA 33523 DEL EGA TED ENGINEER OF RECORD Digitally signed S01'"1111'i11f by James Curtis •� N. • . Date: OF 2016.07.22 " ,•., �' •!lOR1vlk- '09:25:32 -04'00 'QN"'-``��� �j�+1►I�i��i C*C* �� C9Cp c')00 04 N W W Z �o� \ cam LU 1� Z N W o0 N N WMM v zwui �CLU3 c U) Z 0 / j 0 = Z LU 00- LU � N 0 -� Ax W Z 0- 0 cn 0 VJ Z 0- o W W 0 0 I LU LL z O F- L) U W 0 Y U 0 U W Q O LU =3 W U 2 r NT CM cM C Q fir- 0 Qw 0 ___I LJL U) O J om Q J = � O = LL7 LLM O11`�_ N DRAWN BY: B. KNICKLE CHECKED BY: F. REINHART ISSUE DATE: 7/19/16 JOB #: 292415807 PROJECT #: 292:993523001 SIMPLEXGRINNELL © 2016 SYSTEM: FIRE ALARM SYSTEM SHEET: GENERAL INFORMATION FA-002 ok i N N_ 0 N N N 0 w z a F— p 10 (2. 0)) 30 (4. 0 1 l 01( 6.0� (7�.O (80 (�!,o I i C A �I r AM 3 !1 EX M 2. ISLATION EXAM 1 ! SORATION i 2v - 112s EXAM 4 OFFICE ISOLLPAITION' 25 _.15 Ii�V17-6 _ ILL.�II f Y 1127 15 10K 1 53 LL l, p, Yt—FF T1. 1 '� �-- I i' 15 .25W I 2V 2S,2V YJ,V I I I C.V15-t4 CORRIDOR JB JB 1• S,V ! -,\T1SS 3-13 S,V 15 II JB T1:V17-5 JANITOR jVYj ly�ry'!j 2V 25W I EXAM 11 I T1:V17-4 , 1 11 s T1:S3-12 I 1:V17-9 I 15 NURSE - - - A - - - - - - - - - E.0 EXAM 7 I'I CART STATION - T1! 6 ELEVATOR OFFICE SECLUSION T1:V1 S'V WASHER : - 7-3 SOILED 2S,V - ---- 1I 15 F j DIRECTOR L� NGE JB 2S,v EXAM 8J,. HOLDING - I - -- DO \ OFFICE T1:V17 2 -- - ,'I ELEVATOR DECONTAMINATION 15 I U: A I _ I I --u � 1 I I I i F EXAM 12 _ �l WOMEN F0 I 1115 LOCKERS T1 1 35 -- I II' -., S v I' WOMEN E _ ,^ it � z ! DECON ELEVATOR SHOWER EXAM 13 CORRIDOR CORRIDOR CITED!�- Imo. � _ - --- LOCKERS T1 T11:S3 5W ! J - - -- i 11II -- 10K 15 --- - 15 STAFF 71:V15 2S,V EXAM 9 U - Tt:V17i-1 2v T1:v15-12 - LOUNGE ,per TRANSITION I� � L - 15 L-- T1:S3-7 15 E CORRIDOR III ELEVATOR �� f STORAGE LEAN T1:V1 116 B --- 5W ~ I; HOLDING 12 z EXAM 14 2S,v EXA 10 1 1214 :' 113 SEC RE M1-34O �- J S V 15 HOLD II E :D1-10 ELEVATOR E - - --- - - EQUIPMENT T T'IU15 1.1 EQU � 1 - - - - - - - - - - - - - - - - - - 2v - - - - - - - - - -- -- - j - - - - - - - - - - ( G1 I 1 M EXAM 36 EXAM 34 2v EXAM 33 - - - - - - - - - - T1:V16 ± c 15 15 10K u �� h 15 15 15 III ;1 ! EXAM 32 15 - T1:V16 =-� _ 1 I T1:V5- T1:V5-5 T1:V5-4 T1:V5-1 - STATION T :V15- I CONSULT O — T1:D1- • 15 dB, I 2 T :M1-32 �15 CORRIDOR T1:V16 12 2V 2 143 - E 2V T1.M1 3 --- — 1.V5 3 S V I ATIENT T 1 1 ! �` -- S,2V �J t t 46 2V 2V -� I� VESTIBULE 2V T1 - _ • EXAM 15 I � — --- T1:S2-3 % I 1111 CORRIDOR 1147 T1:M1—Zs 15 w •5W 1C3 2S,2VS,2V T1:M1-30 S,2V T1:M1-27 D,M,P,V D,M,P,S,V D,M,P,S,V j D,M,P,S,V 2S,2V / �; T1:V16-11 JB JB Z 2 2 JB JB JB JB JB EXAM 16 15 T1:S3-11 T1: 1-29 S,2V CORRIDOR D,I�,P,S,V 2V t t o9 25W 15 .5W 15 t 2c 1 T1:V15-10 2 T1:D1-7 T1:V5-10 V 2V NURSE S'Zv --' 15 T II r�—I STATION 1 1:S2„ I �t� 151:V16-9 S IL I (— 2V EXAM -' - I 10K - - .. ! H LD 2 13 - 5 - _ EXAM 31 2S,V 6 r 1219 lb7 11os 4 15 --i Y V5-9 T1 V5-8 T1:N�.� 1 15 - -- I C DMPSV `' ` '' i �I -:� 2V - JB T1:V4 I I I 15 15 I EX 39 AM -- EXAM 37 - - -EXAM _3� t 0K zt�- - - - - - - - - - - - - -_ - - - - - - - - - - - - - - - - �', i - II \,71 2V 1 �2G�� 1203 y` 1205 1207 S - Th O T1:V15-8 T1:V4-16 - - _ - I EXAM 17 :: 11s1 1 T1 V15-Z-a�? .. y 5 `, 15 / , - 1 JB 15 SHOWER T1:V4- I I - 1202 - I 1204 12os t 2oa � •� I S 2v 2 ' 2v I _ �I CORRIDOR ' , SV s, F t" j i222 12C2 - �y - 2S,2V _ - f f XA 18 i R R — = � - D,M,P,S,2v I M _ COR IDO JB \.25W' 25W ` aY5 I - EXAM 30 ' PEDS C ,, I �J �T BREAK 2V ; , 6 1224 11 C2 T1:V1-6 fF `i. 1103 " Il NURSE T1:S3-l; I '1__ _-- STATION --- �' - I 242 1244 124s 1�48 T1:V4-1 JB T1 V16� 2V 2V 1105 I 15 !�t rV 1 I'DMPS2V OBSERVE _:• ! 1 -= ,,' = i ` �. - 11 CARE 7 I� � 2S V I : I I�I T1 •V16 6 f 11' j 15 (_ 1 62 EXAM 20 P.. _-, EXAM 2 I EXAM 24 EXAM 26 T1:V4-t 2 XAM 19 PEDS ,�I �j --- 1241 1 1245 1247 I AM Y -Tr,: S,2V t 5 I a e 15 15 j. 15 X 1226 1243 ``� Lt02 E 29 ); T1:V16-7 1' �1 , T1:V4- JB T1: -4 1:V4:-7 �, 26 10 9 8 �li ,,�I _ �'� D,M,P,S,2v 15 T1:V1 CLEAN E l -- I� NURSE j �\ - - - - 61 104 TTivc3-5 i_ r STATION 2V T1:V4-1 �- - - - - - 1 15 JB _ 5 P - - - - - - _ _ - r - - - - - -I `�J l 5W D'M' T1:S2 2 SOILED \ S,2V 5Vy 2S,V D,M,P,S,3V JB 15 5W JB JB HOLDING - U DMPS2V ! Ili T1:V16-3 92V S,2V S,2V S,3V S,3V Tl: 1-6 T1:M1-25 D,M,P,S,2V D,M, S,2V 227 I T1:S3-10 2S,2V 1101 15 JB JB JB J 2 JB �>'�\� CORRIDOR 2S,2v T1:M1-26 D,M,P, ,3V CORRIDOR 11c1 .25W 15 I T1:D -5 D,M,P,2S,5V t2c3 .5W 15'� SMOKE CfOMPART ENT J 2V V 0 2V T1:V15-2 2V � 2V 2V 2 15 I 1 10K J' I AAl 1:M111240 -cl ; 1 T1:V3-15 :V3 f1:V16-2 T1:V1 -1 :V15-4 2S,2V T1:M1 I �V SMOKF, COMPARITMEP�- I -- -- I� i - �' I I _ CLEAN �^ 15 - 15 !I 15 O T1 1-22 t 228 . _ �- �� - 1. - .V4- 1.V4-8 T1. - REGISTRATION I EXAM 21 T1: -5 T V EXAM 23 EXAM 2Tt 9 T V4 1 FAST FAST FAST 25W T1 D1- 1 1 15 EXAM 28 TRACK �' TRACK TRACK TRACK I , 1025 T1:V1 I EXAM 27 T1:S�' , 6__' LD Sl--------- D M, 2S,5y -: 1- ( .25W BEREAVEMENT OFFICE O 1015 it O O 1238 I � 1236! 1234 , 1232 I I ' ' 101o I i 1 1240 , 1 CORRIDOR :' 1 r �J 1 I 1 0C1 ' — CONFERENCE S,V --- EMR • - OFFICE 1304- t3o5 �- % ELECTRICAL D,M ,2S,5V T1.M1j O 307 CIRCULATION T1:M1 3 017 I I 1302 0 1 T1:M1-13 I RECEPTION 1014 O 71: -14 1 I 2 UPS Tt: -15(7> .25W I - 303_ n', T1:M1-9 _ DR SLEEP ELEVATOR IT1:V15- j T11M1- T1:M1-8 1306 loE1 Tta3- f OFFICE O 2S,5V 301 l T1:V3-9 V li 1 JB Z T1:M1-2 D 1,21S,3V LAP,ZS,5V CORRIDOR S,V VESTIBULE 1 21D,4,P, v 1008 T , ,P,4S,7V 2V T1:M1-7 2V CORRIDOR JBU T1:M1-61 .5W aS,2V-------- OFFICE 1:V3- r 15 :S1- , I T1:V3-6 1007 J 15 SECURITY i loos I I i 1 D,M,P,5S,7V I i - - - - - - - - - , - SUPPLY ROOM CT SCAN CONTROL COMM 019 2D,M,P,5S,7V IT1:M1-1 2CL x I I 1 I T1:M1-4O O T1:M1-5 CORRIDOR 2S T1:V3 1 T1:S1 15 q 15 T1 V3 317 Tf:V3-2 ! JANITOR --1Cl005 15 -- �CC.4 - - - - - - - - - - - T I - _ MEN WOMEN , _ I I T1:S1-2 1003 1004 SMOKE COMPARTMENT 1A J SMOKE COMPARTMENT 1B J� —I— RAID H.C. SMOKE CO ELECTRICAL O2E :M T1-10 EQUIPMENT ALCOVE FUTURE CT SCAN TME-N I \ ' - -- - TMENT 1B El STAIR B i� STORAGE i i RAID j! ECHO NOTES: O FIELD VERIFY EXACT LOCATION OF TRANSPONDER. O2 FIELD VERIFY EXACT LOCATION OF RISER. O3 FIELD VERIFY EXACT LOCATION OF SMOKE DAMPERS AND DUCT DETECTORS. O FIELD VERIFY EXACT LOCATION OF RIAM FOR DOOR CONTROL. North E W S UNLESS OTHERWISE SPECIFlED � LOCATE IN CEILING TILE BELOW � � DUCT DEFECTOR � IX P (FOR SHUT DOWN) I 1 1 K R M i 2 p i I TYPICAL I DUCT DETECTOR , DETAIL ELEVATOR MACHINE ROOM 1017 . T1:M1-16 PRIMARY RECALL 1 T1:M1-17 ALTERNATE RECALL TIIA1-18 ELEVATOR CAB LIGHT IT1:M1-19 SHUNT TRIP POWER I i r T1:Mt-20 SHUNT TRIP MONITOR i ®®® NM R TO SHUNT RIP BREAKER I ELEVATOR CONTROLLER I ------------------ 1 ( FIELD VERIFY EXACT LOCATION) FIRST FLOOR FIRE ALARM SYSTEM SCALE: 1 /8" = 1'-0" t 0 M �00 OP_ N ti to cp C C-) Coco LID N W wz �0j` �n=.Q¢u' d 0 w z Uoo o 0 N CN NCO M Of co Cr! N jJ� 5 a U oaj 0 oaf Z O <C J > J O= Z LU O� = W � N LL � O -J W Lff) Z � M Q � O _j z= �w0 cf)O �cp 0 Om_j QJ = W� 0(� M o�w W Li.. o N DRAWN BY: B. KNICKLE CHECKED BY: F. REINHART CURTIS ENGINEERING SERVICE, LLC - CA#31561 ISSUE DATE: 7/19/16 JAMES M. CURTIS, P.E. - PE#37912 JOB #: 292415807 29775 BAYHEAD ROAD PROJECT #: 292:993523001 DADE CITY, FLORIDA 33523 SIMPLEXGRINNELL © 2016 DEL EGA TED ENGINEER OF RECORD SYSTEM: Digitally signed by James Curtis �`�'�`�`"��''•��'' Date: '0. AiEtfF 2 016.0 7.2 2oR,,*: ' ft '09:26:18 -04100 oj"{�t��```` FIRE ALARM SYSTEM SHEET: FLOOR PLAN -FIRST FLOOR FA 101 O p 0�-7 ON 04C) 00 CO u C? 04 co 0000 0000 04 04 lJJ t= L 0 u co 7.0) 8, 3.0)�1.013.0 1 74�0 6. 0) (17.0 0 of Ifn 5.0 )(670)C3 r T' t-�- W rm Z 04 L.LJ co 55 04 C; CD c" _ 00 11H C�u > B 4� ED 12 -< ui . ............ ... F-m co JANITOR CORRIDOR TOILET LET .0 . ........ . ..... .. .. ... ..... (G1 NURSE OIL S T STATION DICTATION CARDIAC PREP TOILET BED 14 PIE�POST 4 S ION T� =�4 PRE�POST PRE/POST PRE/POST PRE/POST PRE/POST 5 FCLEAN - CORRIDOR SOIL - ----------------- ------ ---------------------- ---------------------- ---------------- ------- ---------- ------------------- - PRE POST PRE/PAST PRE POST PRE POST PRE POST PRE POST PRE/POST PRE/POST 0 13 12 H 1 CLEAN TOILET G2------- ------ - ----- ------- i TOILET- — - — - — -- — - — - — - JANITOR TOILET TOILET J-- CONSULT f -------------- 7H *9OR--- T F— TiF 75 .5W D,M,P,S,2V 75 .5W T1:V21-2 T1:V21-3 TOILET Tl:S4-2 T1:S4-3 PRE -OP WOME S CENTER WAITING WAITI G ROOM ; I RECEPTION F, 2 1=03 0 - — - — - — - - — - — -- --EtECTRt0AL --Tofl-f�-- - ; I2S,2V cn 1 .2, T1:V21 1, SMO'6� COMPA�TMENT 2H T.1 4 -1 > ELEVATOR --00e LOBBY 0 7 1 C2101 ROOF SA40 COMPARTMENT 2A LLJ c >--�'v 0 S COM'PARTIMENT 2H uj SMOKE COMPARTMENT 2H - - 4r -- - - - - + — - — - — - PAR M- - - - - - - - - - - - - - ENT IS . . . . .. ... ...... . . . . .... ................ ............ . . . .. -------- . ... ...... .... . . . . . . . . . .... . ..... . . ........ - - - - - - - - -- - ----- 0 'FF 2 CORRIDOR LDR POST POST PRIVATE PRIVATE PRIVATE PRIVATE PRIVATE - — -- — - -- PARTUM PARTUM PATIENT PAT ENT PATIENT PATIENT PATIENT 5MC)KE OMP ENT 2B 05 T1:M1 -45 LO cy) 0 C/) C) Q 0 < T1: -46 STAIR B > 0 M'�'v T1: 01-47 LL. ELEVATOR CORRIDOR cn 0 cn CiKD x"/ 0 cn —J 'x/ I V X (EE - — - — - — - — - — - — - — - — - — - — - — - -- — - — -- Of < IL Lu . ... .. CD LDR 30 TO SMOKE COM�ARTMENT 2C 0 .j 0 U-) -D,M,P,S CORRIDOR CORRIDOR Lu LL -j ai LU u- P�' 11,14 75 ------------- - - --- - ------ - LDR �URSE NURSE II 3 STATION STATION MD (DID. I,/,— CORRIDOR NOURISHMENT ('DD .'4 HOLDING LDR - — -- - — - — - — - (DID.6" - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - - #� r OFFICE I DOCTORS El I CLEAN LOCKERS EAN/ t�l CORRIDOR MEDS FE— (PHASE 2) z CORRIDOR HOLDiN .. .. . .......... X, (cc i)--- — - — - — -- . ........ . STAFF C-) U) CORRIDOR LOUNGE LOCKERS CLEEP (PHASE 1) (c C. 4� - — - — - — - — - — - — - — - — - — - — - I_' \, LDR SCRUBS] SCRUB HOLDING SMO�E COMP AIMENT: �SMOKE CO PART 'B S] Lu Lu U) < NOTES: 0 FIELD VERIFY EXACT LOCATION OF RISER. 3.1 3.9) 5.6) C6 DRAWN BY: B. KNICKLE CHECKED BY: F. REINHART CURTIS ENGINEERING SERVICE, LLC - CA#311561 ISSUE DATE: 7/19/16 JAMES M. CURTIS, P.E. - PE#37912 JOB #: 1292415807 29775 BAYHEAD ROAD PROJECT#: 1292:993523001 DADE CITY, FLORIDA 33523 SIMPLEXGRINNELL@ 2016 DEL EGA TED ENGINEER OF RECORD SYSTEM: FIRE ALARM SYSTEM SECOND FLOOR M111/y/1 SHEET: North E Digitally signed 'p M. C& v/z (PHASE 1 FLOOR PLAN SECOND :)YJamesCurtis FIRE ALARM SYSTEM FLOOR (PHASE 1) No. SCALE: 1/8" 1'-0" Date: S w S OF (1 3r� �TOILET L)iT rI' L "S' 2'- 1 2 T1 -.V2; 1 T.I.S S4 1 L COMP Ti.- 2016.07.22 '09:26:51 -04'00 opt FA- 102 co O co 0 co CL H CV U f— ¢ d LU J_ U- p ON Lp Lp N C) N N N_ 0 W z_ a U) p N W W U a CN •r X CD M SMOKE COMPARTMENT 2H T1:M1-47 T1:M2-46 T1:MZ-45 M M M ELEVATOR ELEVATOR ELEVATOR TOP OF TOP OF LOBBY SHAFT SHAFT z1o1 z0E1 LNE1 D,M P,S T1:V21-3 T1:V21-2 T1:V21-1 SMOKE COMPARTMENT 2G SMOKE COMPARTMENT 2G SMOKE COMPARTMENT J� t F �T1:M1-61 K R K R T1:M1-62 T1:M1-63 T1:M1-64 M M T1:M1-67 M M M M M 2 2 2 2 2 T 2 F COMM ELECTRICAL CORRIDOR WAITING T1:M1-65 P T1:M1-66 CORRIDOR 2221 U zzEt zzls NURSE CORRIDOR 2zEs STATION C 22E1 _r— _ _ _ — 2223 P NAC:V1-1 NAC:V1-2 NAC:V1-4 NAC:V1-9 NAC:V1-10 NAC:V1-11 T1:S5-1 T1:S5-2 NAC:V1-3 T1:S5-3 NAC:V1-5 NAC:V1-6 NAC:V1-7 NAC:V1-8 T1:S5-4 T1:S5-5 T1:S5-6 tOK 5W 15 V .25W 15 V 15 V.25W 15 V 15 V 15 V 15 V 15 V.25W 15 V .25W 15 V .5W 15 NAC:V1 ;_---_-c__- c___ SMOKE COMPARTMENT 2G T1:S5 SMOKE SMOKE COMPARTMENT COMPARTMENT 2C 2G I T1:D2-1 D T1:D2-2 WAITING CORRIDOR 2219 22E1 10K T1.S4-3 T1.S4-2 1 1.34-1 5W 75 V 75 V 15 v NAC T1:V21 .5W .25W SURGE PROTECTION SMOKE COMPARTMENT 2H _ NOTIFICATION (MAINTAINL) T1:S4 S S S EXTENDER GROUND TO BUILDING LDINGG GROUND)BEFORE jQK PANEL 6.2ah $$ DEDICATED 120 VAC BATTERY SET LABEL DEDICATED CIRCUIT " FIRE ALARM SYSTEM " COMM T1:M1-60 AND PLACE LOCK OUT 2221 ON CIRCUIT AT PANEL. (FURNISHED AND INSTALLED BY OTHERS) " GROUND CIRCUIT " (FURNISHED AND INSTALLED) (BY OTHERS) -------------------------------------------------------------------------------------------(PHASE 1) ( PHASE 2) SECOND FLOOR T1:V17-10 T1:V17-8 T1:V17-4 1OK T1:S3-14 T1:V17-9 T1:S3-13 T1:V17-7 T1:V17-6 T1:V17-5 T1:S3-12 T1:V17-3 T1:V17-2 T1:V17-1 SMOKE COMPARTMENT IJ'ZilT1:V17 25W 15 V 15 V,25W 15 V 15 V 15 V 15 V.25W 15 V 15 V 15 V 15 V D,M,P,2S,V T1:S3 --- --- --- --- --- 10K L____-7 -____J S S I r ----------------------------------------------------------------J SMOKE COMPARTMENT 1J I T1:V16-11 S T1:V16-3 SMOKE COMPARTMENT 1J SMOKE COMPARTMENT II T1:V16-14 T1:V16-13 T1:V16-12 T1:S3-11 T1:V16-10 T1:V16-9 T1:V16-8 T1:V16-7 T1:V16-6 T1:V16-5 T1:V16-4 T1:S3-10 T1:V16-2 T1:V16-1 T1:M1-16 PRIMARY RECALL � � 1 10K 15 15 15 V .5W 15 V 15 15 15 15 15 15 15 V .5W 15 V 15 15 V V V V V V V V T1:M1-17 ALTERNATE RECALL T1:M1-36 M T1:M1-35 M T1:M1-34 M T1:M1-33 T1:M1-32 M M T1:M1-31 SMOKE COMPARTMENT 1J IT1:V16 i— T1:M1-18 ELEVATOR CAB LIGHT 2 E 2 E 2 E 2 E l E 2 L------------------- J L-------------______________-----_______-----------------J 1 T1:M1-19 SHUNT TRIP POWER CORRIDOR CORRIDOR CORRIDOR ELEVATOR ELEVATOR CORRIDOR S______________________ FRONT OF FRONT OF EQUIPMENT EQUIPMENT zc1 1 r T1:M1-20 SHUNT TRIP MONITOR ELEVATORS ELEVATORS T1:V15-15 T1:V15-13 T1:V15-12 T1:V15-10 S T1:V15-6 T1:V15-5 T1:V15-3 T1:V15-2 T1:V15-1 T1:V15-16 T1:S3-9 T1:V15-14 T1:S3-8 T1:S3-7 T1:V15-11 T1:S3-6 T1:V15-9 T1:V15-8 T1:V15-7 T133-5 T1:S3-4 T1:V15-4 T133-3 T1:S3-2 T133-1 �— 2 ® ® ® NY R TO SHUNT TRIP 2 2 2 M I 10K 15 V .5W 15 V 15 V .5W 15 V .5W 15 V 15 V.25W 15 V 15 V 15 V 15 V.25W 15 V .5W 15 V 15 V.25W 15 V.25W 15 V.25W 15 V X P BREAKER X P SMOKE SMOKE X P �./ P X SMOKE COMPARTMENT I I J T1:V15 --- --- ------5--- --- --- SMOKE SMOKE COMPARTMENT 1A COMPARTMENT SMOKE COMPARTMENT SMOKE COMPARTMENT 1B SMOKE COMPARTMENT J �/ COMPARTMENT COMPARTMENT SMOKE COMPARTMENT SMOKE COMPARTMENT --- i i --- -5--- --- i i ___---T--- __-T--- __1--- i 1 i i DOOR C L _j L___-T____J L____T____J L________________T________________J L____-I-____J C S S S T1:M1-1 T1:M1-2 T1:M1-3 T1:M1-4 T1:M1-5 T1:M1-6 T1:M1-7 T1:M1-8 T1i9 T1:M1-10 K T1:M1-11 R T1:M1-13 T1:M1-14 T1:M1-15 ELEVATOR CONTROLLER K R T1:M1-22 coNTRo1 T1:M1-23 T1:M1-24 T1:M1-25 J T1:M1-26 T1:M1-27 K R K R J T1:M1-30 S S S S M M M M M M M M M M M M M M M M M M M M M M M M M M 2 2 1 2 2 2 2 2 2 22 2 1 2 r---------------- 2 2 2 2 2 2 2 2 2 T1:V5-10 T1:V5-2 COMM VESTIBULE ELEVATOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR UPS ELECTRICAL ELECTRI AL CORRIDOR T1:M1-12 CORRIDOR ELEVATOR ELEVATOR -----_----------� T1:M1-21 CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR T1:M1-28 T P T1:M1-29 CORRIDOR T1:V5-11 T1:S2-4 T1:V5-9 T1:V5-8 T1:V5-7 T1:V5-6 T1:V5-5 T1:V5-4 T1:V5-3 T1:S2-3 T1:V5-1 10K 15 V .5W 15 V 15 V 15 V 15 V 15 V 15 V 15 V 15 V .5W 15 V 15 V 019 oos O '� PIT 10E1 1307 1 CORRIDOR I 0c1 MACHINE MACHINE O 101 I I oc1 �- I I CORRIDOR loci I o 1 �- oc1 12c z 3 CO c1 zc1 I O I CORRIDOR 12C, CORRIDOR 12C1 ' C3 O SMOKE COMPARTMENT 11 T1:V5 --- - - - - - - - - - - T - - - - - - - - - - - _ - J - - _ - - - J - - - - - - - - - J SMOKE i I PSMOKE P P COMPARTMENT COMPARTMENT 10KL ----------- ----------------------------T--------------------- __ ----J I u u T1:S2 S I SMOKE SMOKE SMOKE SMOKE SMOKE SMOKE SMOKE SMOKE SMOKE SMOKE r---------------------------------------------------------------------------------------- I---------------------------------------------------------------------------------------- J COMPARTMENT COMPARTMENT COMPARTMENT COMPARTMENT COMPARTMENT COMPARTMENT COMPARTMENT COMPARTMENT COMPARTMENT COMPARTMENT _ T1:V4-11 S T1:V4-2 1A iJ 11 11 11 11 11 11 11 11 T1:V4-16 T1:V4-15 T1:V4-14 T1:V4-13 T1:V4-12 T1:S2-2 T1:V4-10 T1:V4-9 T1:V4-8 T1:V4-7 T1:V4-6 T1:V4-5 T1:V4-4 T1:V4-3 T1:S2-1 T1:V4-1 T1:D1-1 T1:D1-2 T1:D1-3 T1:D1-4 T1:D1-5 T1:D1-6 T101-7 Tl'D1-8 T1:D1-9 T1:D1-10 1 1 10K 15 V 15 V 15 V 15 V 15 V .5W 15 V 15 V 15 V 15 V 15 V 15 V 15 V 15 V 15 V .5W 15 V 15 V D D D D D D D D D D SMOKE COMPARTMENT III T1:V3 ___ ___ ___ ___ CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR L--------------------------------------------------------------J L-------------------------------_-------------r-_-_----------- ------------ _--_-----__----_--J L------T------ tOC1 10C1 72C3 12C3 11C1 12C1 11C3 12C1 S SMOKE S S COMPARTMENT T1:V3-12 T1:V3-11 T1:V3-10 111 T1:V3-8 T1:V3-4 T1:V3-1 T1:V3-15 T1:V3-14 T1:V3-13 T1:S1-6 T1:S1-5 T1:S1-4 T1:V3-9 T1:S1-3 T1:V3-7 T1:V3-6 T1:V3-5 T1:S1-2 T1.V3-3 T1:V3-2 T1:S1-1 10K 15 V 15 V 15 V .5W 15 V .25W 15 V .5W 75 V 15 V .5W 15 V 15 V 15 V 15 V �V25W �1525W SMOKE COMPARTMENT IA T1:V3 ---� ��5� 2D,M,P,5S,7V 55--- i---- ---� --- -- S -- 1OKL'---- L---------------- ---------------- J L----------- T1:S1 5----J 5----------J 5 Fx-P—D-Rl SURGE PROTECTION FIRE ALARM ( MAINTAIN Y min. OF WIRE BEFORE PANEL) TRANSPONDER ( SECURE GROUND TO BUILDING GROUND) $$ DEDICATED 120 VAC 25ah BATTERY SET LABEL DEDICATED CIRCUIT " FIRE ALARM SYSTEM " (2 CABINETS) AND PLACE LOCK OUT ON CIRCUIT AT PANEL. (FURNISHED AND INSTALLED BY OTHERS) ---�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�---GROUND CIRCUIT--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�..--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�--�-- (FURNISHED AND INSTALLED) (BY OTHERS) C O M -------- ------ FIRST FLOOR �co �C9 04 CoM Coco CV LLI W 0 Z 5�LL 1� C3- 1� Z N (LU co o 0 N (nzi;CNO N Wmv fn . �!-ja0 ZW6i U =1a9 12 N LoMLU c ��uWi Z 0 J J 0= Z� LIJ �. 0 0— Uj � N 006 -� r Z Liz M 0 � vJ ' / - Q �0 z= QQ � Jo 0— 0 U)0C/) 0 m J LJJ r1/ Q J = Q O _J 0 Lo W LU t.L u- o N z O F- a Ix U U LU 0 DRAWN BY: B. KNICKLE CHECKED BY: F. REINHART CURTIS ENGINEERING SERVICE, LLC - CA#31561 ISSUE DATE: 7/19/16 JAMES M. CURTIS, P.E. - PE#37912 JOB #: 292415807 29775 BAYHEAD ROAD PROJECT #: 292:993523001 DADE CITY, FLORIDA 33523 SIMPLEXGRINNELL © 2016 DEL EGA TED ENGINEER OF RECORD SYSTEM: Digitally signed 11111111tI11/z DyJames Curtis ;, No.3 Date: ~ '° 2016.07 22 '� `'• OR ��� '09:28:05 -04'00 %N FIRE ALARM SYSTEM SHEET: RISER DIAGRAM FA-201 FLORIDA HOSPITAL ZEPHYRHILLS ED EXPANSION 4100es XPDR Standby Total Alarm Total Module Oty Description Current Standby Current Alarm Panel Equipment 4100-9601 1 LOCAL MODE TRANSPONDER 0.0870 0.0870 0.0870 0.0870 4100-0621 1 ANALOG AUDIO RISER MODULE 0.0150 0.0150 0.0150 0.0150 4100-0634 2 POWER DISTRIBUTION MODULE 120V 0.0000 0,0000 0.0000 O.00OD 4100-0636 1 BOX TO BOX HARNESS KIT 0.0000 0.0000 0.0000 0.0000 4100-1361 2 ANALOG FLEX 35W AMP W/3 NACS - 25V 0.0850 0.1700 1.6400 3.2800 4100-2163 2 INDICATOR ONLY, 3 BAY SOLID DOOR 0.0000 0.0000 0.0000 0.0000 4100-2300 3 IEXPANSION BAY (PHASE 10 ONLY) 0.0000 0.0000 0.0000 0.0000 4100-2320 1 JAUDIO EXPANSION BAY KIT 0.0000 0.0000 0.0000 0.0000 4100-5101 3 EXPANSION PWR SUPPLY (XPS) 120VAC 60HZ 0.0500 0.1500 0.0500 0,1500 4100-5111 1 SYSTEM POWER SUPPLY (SPS) 120VAC 60HZ 0.1750 0.1750 0.1850 0.1850 4100-5128 2 EXTERNAL BATTERY POWER 0.0000 0.0000 0.0000 0.0000 Panel Totals 0.5970 3.7170 IDNet Addressable D vices (SLC) 4099-9004 1 AODRESSABLE SINGLE ACTION MANUAL STATION Constant current draw of .8mA standby and 1mA alarm per address used. Devices requiring additional current are accounted for in the section labeled "Miscellaneous Peripheral Devices Requiring Additional System Power". 4090-9001 1 IDNET SUPERVISED IAM 4090-9002 5 IDNET RELAY IAM 4098-9714 29 TRUEALARM PHOTO SMOKE SENSOR 4098-9733 4 �TRUEALARM HEAT SENSOR 4098-9756 6 TRUEALARM DUCT SMOKE SENSOR W1 RELAY OUTPUT 4009-9201 1 4009 IDNET NAC EXTENDER, 120 VAC 4098-9792 33 TRUEALARM SENSOR BASE Miscellaneous Peripheral Devices That Require (Additional) System Power 4098-9843 1 6 JENCAPSULATED RELAY PAM-SD 0.0000 1 0.0000 1 0.015-0 1 0.0900 4098-9756 1 6 [TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT 0.0030 1 0.0180 1 0.0150 1 0.0900 Notification Appliances 4906-9101 58 V10 MC NON -ADDRESS, RED, WALL 15 0.0000 0.0000 0.0600 3.4800 4906-9151 22 S/V M-C NON -ADDRESS, RED, WALL 15 0.0000 0.0000 0.0600 1.3200 4906-9151 3 S/V M-C NON -ADDRESS, RED, WALL 75 0.0000 0.0000 0.1860 0.5580 4906-9154 2 S/V M-C NON -ADDRESS, WHT, CEILING 15 0.0000 0.0000 0.0750 0.1500 Peripheral Totals 0.0180 5.6880 RUI Totals 0 0.0000 0.0000 Address Totals 47 Addresses 0.0376 0.0470 Device Address current draw included below (See Additional Current Draws): System totals*: Standby 0.6526 Alarm 9.4520 2. Backup Amplifier assumes Main Amplifier alarm current on failure. Standby Standby Alarm Alarm Battery Set #1 (Cabinet/Charger #1) Current Total Current Toto I Select ALL Power Supplies on this battery set: - SPS-1 0.2770 2.9330 XPS-2 0.2200 3.3300 XPS-3 0.0500 2.4800 XPS-4 0.0680 0.6620 Sub Total 0.6150 9.4050 Additional Current Draws: MAPNET/IDNet Device Address Communication Current 47 x 0.000800 = 0.0376 x 0.001000 0.0470 Sub Total 0.6526 9.4520 Spare addressable point capacity 0% 0 x 0,0008 = 0,0000 x 0,001 0.0000 Total 0.6526 9.4520 Standby Time = 24 Hrs Alarm Time = 15 Min Additional Spare Battery Capacity = 0% x 0.6526 15.6624 Standby Ah 0.25 x 9.452 2.3630 Alarm Ah 18.0254 Battery Discharge Factor = 20% Minimum Battery Required 2081-9287 25AH (2x) Battery Supplied 2081-9287 25AH (2x) + 3.6051 21.6305 FLORIDA HOSPITAL ZEPHYRHILLS ED EXPANSION 4009 NAC Module Qty Description Standby Current Total Standby Alarm Current Total Alarm Panel Equipment 4009-9201 1 14009 IDNET NAC EXTENDER, 120 VAC 0.0850 0 0850 1 0.1850 1 0.1850 Panel Totals 0.0850 0.1850 Notification Appliances 4906-9101 5 �/O MC NON -ADDRESS, RED, WALL 15 1 0.0000 0.0000 0.0600 0.3000 4906-9151 1 6 IS/V M-C NON -ADDRESS, RED, WALL 15 1 0.0000 0.0000 0.0600 0.3600 Peripheral Totals 0.0000 0.6600 RUI Totals 0 0.0000 0.0000 Address Totals 0 Addresses 0.0000 0.0000 battery Set fl (Cabinet, Select ALL Power Supplies on 4009 Standby 0.0850 Alarm 0.8450 System totals*: Standby Standby Current Total 0.0850 Total 0.0850 Standby Time = 24 Firs x 0.0850 Alarm Time = 15 Min 0.25 x 0.845 Additional Spare Battery Capacity = 0% Battery Discharge Factor = 20% Minimum Battery Required 2081-9272 6.2AH (2x) Battery Supplied 2081-9272 6.2AH (2x) W _j V 0 z �e 0 ry C1 LU U) CO LO CD C) C\1 Q LU CL U) C'4 CD co Alarm Alarm Current Total 0,8450 0.8450 = 2.0400 Standby Ah = 0.2113 Alarm Ah 2.2513 + 0.0000 2.2513 + 0.4503 2.7015 POWER SUPPLY SUMMARY Powered By Ext. Source Module Qty Description Standby Current Alarm Current Qty. ADDRESSABLE DEVICES REQUIRING 24VDC AUX. POWER 4098-9756 1 6 ITRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT 1 0 1 0.0030 1 0.0150 MISCELLANEOUS 24VDC PERIPHERALS 4098-9843 1 6 JENCAPSULATED RELAY PAM-SD 1 0 0.0000 0.0150 24vdc Aux Totals PANEL COMPONENTS POWERED BY POWER SUPPLY 4100-9601 1 LOCAL MODE TRANSPONDER ANALOG AUDIO RISER MODULE POWER DISTRIBUTION MODULE 120V BOX TO BOX HARNESS KIT ANALOG FLEX 35W AMP W/3 NACS 25V INDICATOR ONLY, 3 BAY SOLID DOOR EXPANSION BAY (PHASE 10 ONLY) AUDIO EXPANSION BAY KIT EXPANSION PWR SUPPLY (XPS) 120VAC 60HZ SYSTEM POWER SUPPLY (SPS) 120VAC 60HZ _.RY POWER 0.0870 0.0870 4100-0621 1 0.0150 0.0150 4100-0634 2 0.0000 0.0000 4100-0636 1 0.0000 0.0000 4100-1361 2 0.0850 1.6400 4100-2163 2 0,0000 0.0000 4100-2300 3 0,0000 0.0000 4100-2320 1 0.0000 0.0000 4100-5101 3 0.0500 0.0500 4100-5111 1 0.1750 0,1850 410 0.0000 0.0000 Components NAC Currents from Voltage Drops MAPNET/IDNet Device Addresses used VOLTAGE DROP SUMMARY Class B Spare Plan Circuit Description Load % Drop Circuit Capacity NAC:Vl SMOKE COMPARTMENT 2G SIG1 0.660A 4.95% 67.00% NAC:V2 SPARE SIG2 O.00OA 0.00% 100.00% NAC:V3 SPARE SIG3 O,OOOA 0.00% 100.00% NAC:V4 SPARE SIG4,0.00OA 0.00% 100.00% 10.660A I otal NAC:V1 Distributed Load Voltage Drop Allowable % Drop: G ige: Wire ou Starting Voltage: Circuit Capacity 1197. Wire Res. Per Ft. 0.0028 @ 50* C Min. Device Voltage: elsius 1 6.vdc % Voltage Drop 4.95% 1 1 9.5vd, W2A 2.A Normal Operation Device # PID Candela Distance (Feet) Device Current Voltage Drop Voltage At Device NAC:V1 - 1 4906-9151 15ccl 35 0.060 0.130 19.37 NAC:V1 -2 4906-9151 15cd 45 0.060 0.283 19.22 NAC:V1 -3 4906-9101 15cd 20 0.060 0.344 19.16 NAC:V1 -4 4906-9151 15cd 35 0.060 0.439 19.06 NAC:V1 -5 4906-9101 15cd 30 0.060 0.510 18.99 NAC:V1 -6 4906-9101 15cd 125 0.060 0.764 18.74 NAC�Vl -7 4906-9101 15cd 25 0.060 0.806 18.69 NAC:V1 -8 4906-9101 15cd 50 0.060 0.874 18 63 NAC:V1 -9 4906-9151 15cd 35 0.060 0.909 18,59 NAC:V1 - 10 4906-9151 .1 5cd 50 0.060 0.943 18.5 NAC:V1 -11 4906-9151 11 5cd 65 0,060 0.965 18. 1 otals: I n I JU.bbUA SPS- 1 SUMMARY Qty Total Standby Total Alarm 0 1 0.0000 1 0.0000 0 0.0 ___F0_ COO .0000 0.0000 1 0,0000 1 0.0870 0.0870 1 0.0150 0.0150 2 0.0000 0.0000 1 0.0000 0.0000 0 0.0000 0.0000 2 1 0.0000 0.0000 1 3 0.0000 0.0000 1 0.0000 0.0000 0 0.0000 0.0000 1 0.1750 0.1850 2 0.0000 0.0000 47 0.2770 0.0000 0.0376 0.2870 2,6460 0.0470 Tota 1 0.2770 2.9.�M XPS-2 SUMMARY Qty Total Standby Total Alarm 0 1 0.0000 1 0.0000 0 0.0000 O_ 0.000 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 2 0,1700 3.2800 0 0.0000 0.0000 o 0.0000 0.0000 0 0.0000 0.0000 1 0.0500 0.0500 0 0.0000 0.0000 0 0.0000 0.0000 0.2200 0.0000 0.0000 3.3300 0.0000 0.0000 tol �t0 0.2200 XPS-3 SUMMARY Qty Total Standby Total Alarm 0 0.0000 1 0.0000 0.00 0 0.0000 1 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0,0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 1 0.0500 0.0500 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0500 0.0000 0.0000 0.0500 2.4300 0.0000 Total 0.0500 2.4800 XPS-4 SUMMARY Oty Total Standby Total Alarm 6 1 0.0180 0.0900 6 0.0000 0.0900 0.0180 0.1800 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0000 0.0000 1 0.0500 0.0500 0 0.0000 0.0000 0 0.0000 0.0000 0 0.0500 0.0000 0.0000 0.0500 0.4320 0.0000 Total 0.0680 0.6620 SIPS-1 Configuration XPS-2 Configuration XpS-3 Configuration XPS-4 Configuration Capacity: 9.00OA Capacity: 9.00OA Capacity: 9.00OA Capacity: 9.00OA Ckt. Capacity: 3.00OA Ckt. Capacity: 3.00OA Ckt. Capacity: 3,OOOA Ckt. Capacity: 3.00OA Aux. Capacity: 2.00OA Aux. Capacity: 2.00OA Aux. Capacity: 2.00OA Aux. Capacity: 2.00OA IDNET CHANNEL T1:M1 SWITCH SETTINGS Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 9 T1:M1-1 PHOTO SMOKE SClA COMM 1019 1-1 X ON T1:M1-2 PHOTO SMOKE SC1A VESTIBULE 1008 1-2 X ON T1:M1-3 HEAT H EAT SC1A ELEVATOR 10E1 PIT 1-3 X X ON T1:M1-4 PHOTO SMOKE SC1A CORRIDOR 1-4 X ON T1:M1-5 PHOTO SMOKE SC1B CORRIDOR 1-5 X X --Tff- T1:M1-6 PHOTO SMOKE SC1A CORRIDOR 1-6 X X T1:M1-7 PHOTO SMOKE SC1B CORRIDOR 1-7 X X X ON T1:M1-8 PHOTO SMOKE SClB UPS 1-8 X ON T1:M1-9 PHOTO SMOKE SC1B ELECTRICAL 1307 1-9 X X - - - DN- T1:M1-1O PHOTO SMOKE SC113 ELECTRICAL 1-10 X X T1:M1-11 PHOTO SMOKE SCIA CORRIDOR 1-11 X X X ON T1:M1-12 RPHOTO DUCT SC1J CORRIDOR 1OC1 SMOKE DAMPER 1-12 X X ON T1:M1-13 PHOTO SMOKE SC1J CORRIDOR 1OC1 1-13 X X X T1:M1-14 HEAT H EAT SCIJ ELEVATOR MACHINE ROOM 1017 1-14 X X X ON T1:M1-15 PHOTO SMOKE SClJ ELEVATOR MACHINE ROOM 1017 1-15 X X X X ON T1:M1-16 RIAM PRIMARY SC1J ELEVATOR 10E1 PRIMARY RECALL 1-16 X ON T1:M1-17 RIAM ALTERN SC1J ELEVATOR 10E1 ALTERNATE RECALL 1-17 X X ON T1:M1-18 RIAM RELAY SC1J ELEVATOR 10E1 CAB LIGHT 1-18 X X ON T1:M1-19 RIAM SHAFT SC1J ELEVATOR IOE1 SHUNT TRIP POWER 1-19 X X X ON TI:M 1 -20 IAM SUPERV SClJ ELEVATOR lOE1 SHUNT TRIP MON 1-20 X X ON T1:M 1 -21 RPHOTO DUCT SC1J CORRIDOR 1OC1 SMOKE DAMPER 1-21 X X X ON T1:M1-22 PHOTO SMOKE SC1J CORRIDOR 1OC1 1-22 X X X ON T1:M1-23 RIAM DHOLDER SC1J CORRIDOR 1OC1 DOOR CONTROL 1-23 X X X X ON T1:M1-24 PHOTO SMOKE SC11 CORRIDOR 12C3 1-24 X X -up- - T1:M1-25 PHOTO SMOKE SC11 CORRIDOR 12C3 1-25 X X X ON T1:M1 -26 PHOTO SMOKE SC1J CORRIDOR 11C1 1-26 X X X ON T1:M1-27 PHOTO SMOKE SC11 CORRIDOR 12C1 1-27 X X X X ON T1:M1-28 RPHOTO DUCT SC11 CORRIDOR 12C1 SMOKE DAMPER 1-28 X X X ON T1:Ml -29 RPHOTO DUCT SC11 CORRIDOR 12C1 SMOKE DAMPER 1-29 X X X X ON T1:M1-30 PHOTO SMOKE SC1J CORRIDOR 11C3 1-30 X X X X ON T1:M1 -31 PHOTO SMOKE SC11 CORRIDOR 12C1 1-31 X X X X X ON T1:M 1 -32 HEAT HEAT SCII ELEVATOR EQUIPMENT ROOM 1-32 X 7 T1:M 1 -33 PHOTO SMOKE SC11 ELEVATOR EQUIPMENT ROOM 1 -33 X X ION T1:M1-34 PHOTO SMOKE SC1J CORRIDOR 1 -34 X X X ON T1:M1-35 PHOTO SMOKE SC1J CORRIDOR FRONT OF ELEVATORS 1 -35 X X X X ON T1:M1-36 PHOTO SMOKE SClJ CORRIDOR FRONT OF ELEVATORS 1 -36 X X 1 _�)_N T1:M1-37 X X X T1:M 1 -38 X X XXX X ON T1:M1-39 X X X X ON T1:M 1 -40 X X ON T1:M 1 -41 X X X ON T1:M1 -42 X X - X __T__ N T1:M 1 -43 X X X X ON T1:M1-44 X X X ON T1:M 1 -45 PHOTO SMOKE SC21­1 ELEVATOR LOBBY 2101 1-45 X X X X ON T1:M1-46 HEAT HEAT SC2H ELEVATOR 20E1 TOP OF SHAFT 1-46 X X X - X CN- T1: M 1 -47 PHOTO SMOKE SC21­1 ELEVATOR 20E1 TOP OF SHAFT 1-47 X X X X X ON T1:M1 -48 X X ON T10-49 X X X ON T1:M1-50 X 1 X X ON T1:M 1 -51 X X X X _T__ N T1:M1-52 X X X ON T1:M1-53 X X X X ON T1:M 1 -54 X X X X ON T1:M1-55 X X X X X ON T1:M 1 -56 X X X ON T1:M1-57 X X X X ON T1:M1-58 X X X X ON TI:M1-59 X X X X X 7-N T1:M1-60 NAC4PT SIGNAL SC2G COMM 2221 NAC 1-60 X X X X ON T1:M1 -61 PHOTO SMOKE SC2G COMM 2221 1-61 X X X X X 0 T1:M1-62 PHOTO SMOKE SC2G ELECTRICAL 2220 1-62 X X IX X IX ON T1:M1-63 PHOTO SMOKE SC2G CORRIDOR 22E1 1-63 X X X X X X ON T1:M1-64 PHOTO SMOKE SC2C WAITING 2219 1-64 1 1 IX ON- - T1:M1-65 RPHOTO DUCT SC2G NURSE STATION 2223 1-65 X I I IX ON - T1:M1-66 RPHOTO DUCT SC2G CORRIDOR 22E1 1-66 X I I IX ON T1:M1-67 ADRPUL PULL SC2G CORRIDOR 22E6 1-67 X X IX I ON _ - T1:M1-68 X X ON TI:M1-69 X X X ON T1:M1-70 X X X ON THRU - ON T1:M1-250 IX I IX IX IX IX FX VOLTAGE DROP SUMMARY Class B Spare Plan Circuit Description Load % Drop Circuit Capacity T1:V9 DO NOT USE SIG9 O.00OA 0.00% 100,00% T1:V1O DO NOT USE SIG10 O.00OA 0.00% 100.00% T1:Vl 1 DO NOT USE SIG1 1 O.00OA 0.00% 100.00% O.00OA Total VOLTAGE DROP SUMMARY Class B Spare Plan Circuit Description Load % Drop Circuit Capacity T1:V15 SMOKE COMPARTMENT 1J SIG15 0.990A 10,01% 44.24% T1:Vl 6 SMOKE COMPARTMENT IJ SIG1 6 0.840A B.22% 54,18% T1:V17 SMOKE COMPARTMENT 1J SIG17 0.600A 6.02% 66.43% 12.430A otal T1:Vl 5 Distributed Load Voltage Drop Allowable % Drop: Wire Gouge! Starting Volta ge Circuit Capacity 9% L� 0.0028 Wire Res. Per Ft. @ 50* Celsius Min. Device Voltage: 1 6.vdc % Voltage Drop 10.01% go 19.5ivdc ��3,gA Normal Operation Device # PID Candela Distance (Feet) Device Current Voltage Drop Voltage At Device T1:V15-1 4906-9151 15cd 75 0.060 0.419 19.08 T1:V1 5-2 4906-9151 15cd 70 0.060 0.787 18.71 T1:V15-3 4906-9154 15cd 10 0.075 0.836 18.66 T1:V1 5-4 4906-9101 15cd 40 0.060 1.015 18.48 T1:V1 5-5 4906-9151 15cd 25 0.060 1.119 18.38 T1:V1 5-6 4906-9154 15cd 35 0.075 1.252 18.25 T1:V1 5-7 4906-9101 15cd 10 0.060 1.286 18.21 T1:V15-8 4906-9101 15ccl 45 0.060 1.423 18.08 T1:V15-9 4906-9101 15cd 50 0.060 1.559 17.94 T1:V15-1O 4906-9151 1 5cd 35 0.060 1,642 17.86 T1:V15-11 4906-9101 15cd 55 0.060 1.753 17.75 T1:V1 5-12 4906-9151 15cd 20 0.060 1.787 17.71 T1:V15-13 4906-9151 15cd 50 0.060 1.855 17.6 T1:V15-14 4906-9101 15cd 60 0.060 1.916 T1:V15-15 4906-9151 15cd 50 0.060 1.950 T1:V15-16 4906-9101 15ccl 5 0.060 1.951 lotals: I bJn l­t. JU.99UA Tl:V1 6 Distributed Load Voltage Drop Allowable % Drop i e Gcig,� Wir Starting Voltage� Ckt Capacity Wire Res. Per Ft. 0.0028 1@ 50* Celsius Min. Device Voltage: 1 5.vdc % Voltage Drop -8.22% I �ga% I 19.5vdc 3.A Normal Operation Device # PID Candela Distance (Feet) Device Current Voltage Drop Voltage At Device T1:V1 6-1 4906-9101 15cd 155 0.060 0.735 18.77 T1:V1 6-2 4906-9101 15cd 35 0.060 0.889 18.61 T1:V16-3 4906-9151 15ccl 30 0.060 1.011 18.49 T1:V16-4 4906-9101 15ccl 20 0.060 1.085 18.41 TI:V16-5 4906-9101 15cd 35 0.060 1.204 18.30 T1:V1 6-6 4906-9101 15cd 35 0.060 1.311 18.19 T1:V1 6-7 4906-9101 15cd 1 0.060 1.313 18.19 T1:V1 6-8 4906-9101 15ccl 60 0.060 1,456 18.04 T1:V1 6-9 4906-9101 15cd 1 0.060 1.458 18.04 T1:V1 6-10 4906-9101 15cd 35 0.060 1.517 17.98 T1:V16-11 4906-9151 15cd 40 0.060 1.571 17.93 T1:V1 6-12 4906-9101 15cd 25 0.060 1.596 17.90 T1:V1 6-13 4906-9101 1 5cd 1 0.060 1.597 17.90 T1:V1 6-14 4906-9101 11 5cd 1 20 1 0.060 1 1.604 1 17.90 Totals: 1493 Ft. 10.840A Tl:V17 Distributed Load Voltage Drop Allowable % Wi, Irf re Gauge Starting Voltage� Ckt Capacity 179% Wire Res. Per Ft. 028 @ 50' Celsius � -_� P. i __8 Min. Device Voltage: I NUL; % Voltage Drop 14ga 1 9.5vdc A Normal Operation Device # PID 4906-9101 Candela Distance (Feet) Device Current Voltage Drop Voltage At Device T1:V17-1 15cd 250 0.060 0.847 18.65 T1:V1 7-2 4906-9101 15ccl 40 0.060 0.969 18.53 T1:V17-3 4906-9101 15cd 1 0.060 0.971 18.53 T1:V17-4 4906-9101 15cd 30 0.060 1.042 18.46 T1:V17-5 4906-9101 15cd 2 0.060 1.046 18.45 T1:V1 7 -6 4906-9101 15cd 30 0.060 1.097 18.40 T1:V1 7-7 4906-9101 15cd 1 0.060 1.099 18. T1:V17-8 4906-9151 15cd 50 0.060 1.149 T1:V17-9 4 906-9101 15ccl 25 0.060 1.166 T1:V17_1O 496 �IM�I�ccl 25 0.060 1.175 Totals: 1454 Ft. 10.600A VOLTAGE DROP SUMMARY Class B Spare Plan Circuit Description Load % Drop Circuit Capacity T1:V3 SMOKE COMPARTMENT 1A SIG3 1.026A 9.93% 44. IT1:V4 SMOKE COMPARTMENT 11 SIG4 0.960A 9.20% 48.77% IT1:V5 SMOKE COMPARTMENT 11 SIG5 0.660A 7.38% 58.88% 12,646A Rotal T1:V3 Distributed Load Voltage Drop Allowable % Drop: Wire Gouge: Starting Voltage: Circuit Capacity Wire Res. Per Ft. 0.0028 @ 50* Celsius I Min. Device Voltage: 16.vdc % Voltage Drop 9.93% 19. 5vdc 3,A Operation Device # PID Candela Distance (Feet) Device Current Voltage Drop Voltage At Device Tl:V3-1 4906-9151 15cd 25 0.060 0.145 19.36 Tl:V3-2 4906-9101 15cd 1 0.060 0.150 19.35 Tl:V3-3 4906-9101 15cd 15 0.060 0.227 19.27 Tl:V3-4 4906-9151 15cd 65 0.060 0.537 18.96 Tl:V3-5 4906-9101 15ccl 45 0.060 0.737 18.76 Tl:V3-6 4906-9101 1 5cd 90 0.060 1.106 18.39 Tl:V3-7 4906-9101 15cd 35 0.060 1.237 18.26 Tl:V3-8 4906-9151 15cd 35 0.060 1.357 18.14 Tl:V3-9 4906-9151 15cd 55 1 0.060 1.527 17.97 Tl:V3-1 0 4906-9151 75cd 85 0.186 1.760 17.74 1:V3-1 1 4906-9151 15cd 40 0.060 1.827 17.67 TI:V3-12 4906-9151 15cd 25 0.060 1.861 17.64 TI:V3-13 4906-9101 15cd 45 0.060 1.907 17.59 Tl:V3-14 4906-9101 15cd 20 0.060 1 1.921 17.58 Tl:V3-15 4906-9101 15cd 1 45 0.060 17.56 I otals: I b2b Ft. I1.U2bA T1:V4 Distributed Load Voltage Drop Allowable % Wir D1­013� ie Gauge ' Starting Voltage: Ckt Capacity 17.9% Wire Res. Per Ft. 0.0028 @ 50* Celsius Min. Device Voltage: 1 6.vdc % Voltage Drop 9.20% 14go 19.5vdc 3.A F Normal Operation Device # PID Candela Distance (Feet) Device Current Voltage Drop Voltage At Device Tl:V4-1 4906-9101 15cd 115 0.060 0.623 18.88 T1:V4-2 4906-9151 1 5ccl 25 0.060 0.750 18.75 Tl:V4-3 4906-9101 15cd 25 0.060 0.869 18.63 Tl:V4-4 4906-9101 15cd 25 0.060 0.979 18.52 Tl:V4-5 4906-9101 15cd 40 0.060 1.141 18.36 Tl:V4-6 4906-9101 15cd 1 0.060 1.145 18.36 Tl:V4-7 4906-9101 15cd 65 0.060 1.365 18.13 T1:V4-8 4906-9101 15cd 30 0.060 1.457 18.04 Tl:V4-9 15cd 1 0.060 1.459 18.04 Tl:V4-1 0 .4906-9101 4906-9101 15cd 40 1 0.060 1.554 17.95 Tl:V4-11 4906-9151 15cd 35 0.060 1.625 17.87 Tl:V4-12 4906-9101 15cd 45 0.060 1.701 17.80 Tl:V4-13 4906-9101 15ccl 30 0.060 1.742 17.76 Tl:V4-14 4906-9101 15cd 30 0.060 1.773 17.73 Tl:V4-15 4906-9101 15ccl 30 0.060 1.793 17.71 FT1:V4-16 4906-9101 F15cd 1 1 0.060 __F_ F 1,793 17.71 Totals: 1538 Ft. 10.960A I TI:V5 Distributed Load Voltage Drop Allowable % Drop: Wire Gauge: Starting Voltage: Ckt Capacity 17.9% ire Res. Per Ft. Celsius It 0.0028 @ 50' Min. Device \a age: 1 6.vdc % Voltage Drop 7.38% 14go 19.5vdc - 3.A I Normal Operation Device PID Candela Distance (Feet) Device Current Voltage Drop Voltage At Device Tl:V5-1 4906-9101 15cd 240 0.060 0.894 18.61 T1:V5-2 4906-9151 1 5cd 40 0.060 1.030 18.47 Tl:V5-3 4906-9101 1 5cd 15 0.060 1.075 18.42 Tl:V5-4 4906-9101 1 5cd 40 0.060 1.184 18.32 TI:V5-5 4906-9101 1 5cd 1 0.060 1.186 18.31 TI:V5-6 4906-9101 1 5cd 45 0.060 1.277 18.22 Tl:V5-7 4906-9101 1 5cd 35 0.060 1.337 18.16 TI:V5-8 4906-9101 15cd 50 0.060 1.404 18.10 Tl:V5-9 4906-9101 1 5cd 1 0.060 1.405 18.09 Tl:V5-10 4906-9151 1 5cd 35 0.060 1.429 18.07 Tl:V5-1 1 4906-9101 1 5cd 30 0,060 1.439 18.06 lotals: I bJ2 Ft. 10.660A I VOLTAGE DROP SUMMARY Class B Spare Plan Circuit Description Load % Drop Circuit Capacity T1:V21 SMOKE COMPARTMENT 2H SIC21 0.432A 2.44% 85.60% T1:V22 SPARE SIG22 O.00OA 0,00% 100.00% T1:V23 SPARE SIG23 O.00OA 0.00% 100.00% 10,462A -ilotal T1:V21 Distributed Load Voltage Drop Allowable % Drop: Wire Gauge: Starting Voltage: Circuit Capacity 17.9% Wire Res. Per Ft. 0.0028 Min. Device Voltage: 1 6.vdc % Voltage Drop 2.44% @ 50* Celsius 14ga 19.5vdc - 3.A Normal Operation Device # PID Candela Distance (Feet) Device Current Voltage Drop Voltage At Device T1:V21 -1 4906-9151 15cd 135 0.060 0.329 19.17 Tl:V21-2 4906-9151 75ccl 40 0.186 0.413 19.09 TI:V21-3 4906-9151 75cd 60 0.186 0,476 19.02 totals: 2Jb Ft. 10.432A C14 C=� co 00 ct r-- L? C? co C141 19 CP co CO 0000 04 Lij M LMt= = =3 Cn D_ LL r Of LU 0 W CIO L9 11t - cc C> it - 04 CD Z2; C9 in C14 0� CS 6 LU m - �: 00 _j z LL LIj =1 -::1f2 &.4 q. n- > C:) cn 0 U) > 0 2: Uj 0 13. LU ry 0 06 0 U) 0 < M Uj X 0 M .j Uj U. LD P= W 0 CID! LU LU < 0 LU M W U) LO co M C) < a, 0 01� _j * LU 0 j _j ILL. 0- 7) (/) 0 0 [n _j _j W C:) 0 , _j (=) Uj LL rl- N DRAWN BY: B. KNICKLE CHECKED BY: F. REINHART CURTIS ENGINEERING SERVICE, LLC - CA#31561 ISSUE DATE: 7/19/16 JAMES M. CURTIS, P.E. - PE#37912 JOB #: 292415807 29775 BAYHEAD ROAD PROJECT#: 1292:993523001 DADE CITY, FLORIDA 33523 SIMPLEXGRINNELL @ 2016 DEL EGA TED ENGINEER OF RECORD SYSTEM: Digitally signed A. c(, v,, N , ; ed W_ v., ip V_ by James Curtis "I" ;tr, 4�� 11 % . 0. NO. .00 Date: OF 2016.07.22 "'4010101 N Alk '09:28:48 -04'00 1111110% FIRE ALARM SYSTEM SHEET: CALCULATIONS FA-601 LU z v 0 ry co C3 1111 co F_ cn co 9 f.0 14? C\11 04 c:) 04 04 r- LU F_ cf) w P4 co cq 'T X cn DEVICE MOUNTING HEIGHT REFERENCE (PER NFPA 72) A/C SUPPLY VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS OR RETURN 1 MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO DIFFUSER THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS TOP OF LENS FOR 11 OCD STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" 4 NOTE: MEASUREMENTS (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER 3' (M IN) (102mm) SHOWN ARE TO THE INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. (914mm MIN) CEILING CLOSEST EDGE OFTHE /vx DETECTOR. FOR CEILING HEIGHTS LESS THAN 86" (2180mm), THE VISUAL LENS MOUNTING HEIGHT SHALL BE WITHIN 6" (150mm) OF THE CEILING. C= f9FE— AUDIBLE/VISUAL & VISUAL ONLY APPLIANCES SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF VIEW. REF. 80" MIN (IBC) (2032mm MIN) REF. 96" MAX (IBC) (2440mm MAX) ABOVE FINISHED FLOOR 80" MIN (ADA) 80" MIN (NFPA) TO BOTTOM NOTE: REFER TO THE PROPER DEVICE INSTALLATION INSTRUCTIONS FOR BACKBOX MOUNTING HEIGHT. AUDIBLE ONLY 96" MAX (NFPA, ADA) (2440mm MAX) ABOVE FINISHED FLOOR TO TOP OF LENS (2032mm MIN) (2032mm MIN) OF LENS FINISHED FLOOR NFPA 72 AUDIBLE APPLIANCE 6" MIN (152.4mm MIN) BELOW FINISHED CEILING " CEILING MOUNTED SMOKE/HEAT 4 (1 02mm) 12" (MAX) DETECTOR (305mm MAX) HEAT DETECTORS 90 MIN (2286mm MIN) ACCEPTED HERE NEVER HERE ABOVE FINISHED FLOOR (OTHER MOUNTING HEIGHTS SHALL BE PERMITTED BY THE AHJ PROVIDING IT MEETS THE SOUND LEVEL OUTPUT REQUIRED.) TO EXIT DOOR 5' (MAX.) (1 524mm) DOOR WIDTH LESS 3" (76mm) 5" (1 27mm) MANUAL PULL STATION FIRE PHONE MAGNETIC JACK ME DOOR HOLDER 48" MAX (ADA) 48" MAX (NFPA, ADA) 42" MIN (NFPA) MEASUREMENTS TO TOP OF (1 219mm) (1219mm MAX) (1067mm MIN) SHOWN ARE PULL HANDLE WALL MOUNTED SMOKE/HEAT DETECTOR USE ONLY UL LISTED FIRE ALARM SIGNALING LINE (ADDRESSABLE) CIRCUITS SHIELDING EXAMPLE TWISTED SHIELDED PAIR CABLE UL LISTED FIRE PROTECTIVE SIGNALING CABLES MAY BE SELECTED FROM THE SIMPLEXGRINNELL WIRE & CABLE TABLE, #WIRE TABLE (TSP) FOR IDNETS, DATA COMM. LINES AUDIO, PHONE & SPEAKER IN MIRI�NG IN A FIRE ALARM SYSTEM. SIZE IS 18-2 AWG SOLID STP. PRODUCT INFORMATION ---CUT EXAMPLE: WIRING TECHNIQUES FOR SHIELDED CABLE: #18-2 AWG SHIELDED - SHIELDS AND DRAINS MUST NEVER TOUCH GROUND. TWISTED -PAIR CABLE - MOST GROUNDS ARE DUE TO SHIELDING ISSUES. - MOST SHORTS ARE SHIELD TO CONDUCTOR. TRIM AWAY ONLY - BY CREATING A PROPER PROCEDURE FOR WIRE THE SHIELD AND HANDLING WITH ADDRESSABLE CIRCUITS KEEP THE DRAIN n MOST GROUNDS AND SHORTS CAN BE ELIMINATED. WIRE UNDAMAGED. - ALL UNSHIELDED WIRE MUST BE ENTIRELY IN GROUND CONDUIT. - CONDUIT SYSTEM MUST HAVE A GOOD REFERENCE TO EARTH GROUND SHIELD - PIGTAILS, (T-TAP) WIRING IS PERMITTED TO ADDRESSABLE DEVICES FOR CLASS B CIRCUIT WIRING. '_*` PREPARE THE CABLE BY DRAIN WIRE EXAMPLE FOR REMOVING 2" TO 4" OF WIRING LABELING JACKET AS NEEDED, 0) WIRE REUSE INSULATION—� DISCARD TAG GENERAL WIRING GUIDELINES SHIELD 1. ALL WIRING IS TO BE COPPER CONDUCTOR. ALL EQUIPMENT MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS AND THE SPECIFICATIONS AND STANDARDS OF THE AUTHORITY HAVING JURISDICTION. THE INSTALLATION OF DRAIN WIRE TO PREVENT CONFUSION AND POSSIBLE __�_S'IEL JST REUSE DRAII ALL WIRING, CABLE AND EQUIPMENT MUST BE IN ACCORDANCE ERRORS, ALL WIRES MUST BE TAGGED. WITH NFPA 70, NATIONAL ELECTRICAL CODE NEC), AND SPECIFICALLY SEE WIRE LEGEND FOR TYPES. 'ALLY WITH ARTICLE 760, FIRE ALARM PROTECTIVE SIGNALING SYSTEMS; ARTICLE 800, COMMUNICATION CIRCUITS, WHERE APPLICABLE. 2. IF SHIELDED WIRE IS USED, THE FOLLOWING MUST BE OBSERVED: DRAIN WIRE A. METALLIC CONTINUITY OF THE SHIELD MUST BE MAINTAINED AND INSULATED THROUGHOUT THE ENTIRE LENGTH OF THE CABLE. STRIP OFF APPROX. RED B. SHIELDS SHALL ONLY BE CONNECTED AT THE CONTROL UNIT. 1-2 INCHES OF PUSH REUSED INSULATION SHIELD MUST NOT BE CONNECTED TO, OR TOUCH CONDUIT, ELECTRICAL BLACK INSULATION TO CAREFULLY DOWN INTO BOXES, OR ASSOCIATED HARDWARE AT ANY POINT. SLIDE ONTO DRAIN WIRE. JACKET. SECURE WITH C. THE ENTIRE LENGTH OF THE CABLE MUST HAVE A RESISTANCE GREATER ELECTRICAL TAPE. THAN 1 MEGOHM TO EARTH. D. ALL CONDUCTORS ARE TO BE FREE OF SHORTS AND GROUNDS. 3. UNDERGROUND WIRING MUST BE LISTED FOR APPLICATION AND FREE OF ALL WATER. B�CK 4. WIRING OTHER THAN THAT CONNECTED TO ELEVATOR CABS MUST NOT BE RUN IN ELEVATOR SHAFTS (REF.NFPA 70, ARTICLE 620). REDUCE EXPOSED WIRES TO 5. WIRING IN DUCTS PLENUMS AND OTHER AIR HANDLING SPACES MUST BE LISTED ABOUT 5/16" TO 3/8" FOR FOR PLENUM US� AND INSTALLED IN ACCORDANCE WITH NFPA 70, ARTICLE 300. INSERTION INTO BOX -TYPE 6. SPLICING IS PERMITTED IN ACCORDANCE WITH NFPA 70. ALL JUNCTIONS MUST OR SCREW -CLAMP TERMINALS. BE INSULATED AS SOUNDLY AS THE ORIGINAL JACKET. CONTINUITY OF ANY SHIELD (WHERE USED) MUST BE MAINTAINED. 7. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 8. THE COMMUNICATION CIRCUIT MEETS THE OPERATIONAL CHARACTERISTICS DEFINED FOR A STYLE 4 AND STYLE 6 SIGNALING LINE CIRCUIT. MAXIMUM WIRE RUN NOT TO EXCEED 2500 FT. 9. ALL CIRCUITS ARE SUPERVISED AND POWER -LIMITED UNLESS OTHERWISE INDICATED. SHIELD WIRES ARE NOT SUPERVISED. 10. OPERATING POWER, FOR IDNet DEVICES, MUST ORIGINATE FROM A POWER -LIMITED POWER SUPPLY LISTED FOR FIRE PROTECTIVE SIGNALING USE OR, FROM THE F.A. CONTROL PANEL POWER SUPPLIES INDICATED IN THE APPROPRIATE DIAGRAM. MAXIMUM WIRE NOT TO EXCEED 1KM (3270 FT). 11. WHEN COMMUNICATION WIRING OR OPERATING WIRING LEAVES THE BUILDING, OVERVOLTAGE PROTECTORS ARE REQUIRED; USE 2081-9044, INSTALL ONE WHERE IT LEAVES THE BUILDING AND ONE WHERE IT ENTERS THE NEXT BUILDING. 12. TO PREVENT CONFUSION AND POSSIBLE ERRORS, TAG ALL CONDUCTORS, CODE AT INSTALLATION, TO IDENTIFY CIRCUIT ASSIGNMENT, POLARITY AND IN OR OUT DIRECTION OF THE WIRING. LOG ON AS-BUILTS. 13. LEAVE ADEQUATE SLACK IN THE WIRING TO ALLOW FOR TROUBLE SHOOTING, SIMPLEXGRINNELL IS NOT RESPONSIBLE FOR ELECTRICAL CONTRACTOR'S WIRE CONDITIONS. 14. IDNet COMMUNICATION LINE SPECS.: MAX. 36 VDC @ .5A 15. IDNET MAXIMUM NUMBER OF DEVICES: 3333 BAUD NON -CODED 250 33Q MAX. LINE RESISTANCE CODED PIEZO BASES 43 MAX. 217 ADDRESSES STILL AVAILABLE FOR OTHER DEVICES. INSTRUCTIONS 1. REMOVE ELECTRONIC CARD CAGE (IF PRESENT) AND STORE IT IN A SAFE DRY AREA. 2. NO KNOCKOUTS PROVIDED. CUT CONDUIT/SERVICE ENTRANCE OPENINGS. REFER TO FIG.1 FOR PROPER LOCATIONS. CONDUIT PROTRUSION INTO BOX 1/2" MAX. 3. MOUNT BOX TO WALL: BOX MUST BE LEVEL AND PLUMB. FOR SURFACE MOUNT USE TEAR DROP AND CLEARANCE HOLES ON BACK SURFACE. FOR SEMI -FLUSH MOUNT: USE WALL STUD GUIDES FOR MAXIMUM ALLOWABLE BOX DEPTH TO PROVIDE OPEN DOOR CLEARANCE. USE KNOCKOUTS ON SIDE WALL, SCREW OR NAIL BOX TO WALL STUDS. 4. MINIMUM DISTANCE BETWEEN ANY TWO BOXES IS 3 1/4" (6" MAXIMUM). 5. IF PRESENT, USE WIRE MANAGEMENT BRACKETS ON BOX SIDES TO SECURE WIRE RUNS. 6. NEMA RATING: NEMA 1 - GENERAL PURPOSE. 7. DO NOT LOCATE POWER -LIMITED WIRING IN THE SHADED AREAS OF THE BACKBOX, THIS AREA IS RESERVED FOR NON -POWER LIMITED CIRCUITRY SUCH AS AC POWER, BATTERIES AND CITY CONNECTION. 8. REFER TO SIMPLEX BACKBOX INSTALLATION DOCUMENT 579-117 FOR DETAILED INSTRUCTIONS. --DRAIN WIRE FRICAL TAPE. 4100ES BACKBOX INSTALLATION —11 11/16" — 6 29/32" — 1 7/16" — — 4 3/4 KNOCKOUT —1 SCREW/NAIL--]Fl HOLES FOR SEMI -FLUSH MOUNT (SEE NOTE 3.) WALL STUD GUIDES (SEE NOTE 3.) NOTE: ADA REQUIREMENTS LIMIT THE ALLOWABLE PROTRUSION OF OBJECTS MOUNTED IN PUBLIC ACCESSIBLE WALKS, HALLS, CORRIDORS, PASSAGEWAYS OR AISLES. THE 4 INCH (100mm) RESTRICTION APPLIES TO ANY ITEM IN WHICH THE MEASUREMENT FROM THE FLOOR TO THE BOTTOM OF THE UNIT IS MORE THAN 27 INCHES. IYPICAL CONDUII LUCAIION I -OR PWR. LIMITED FIELD WIRING - - - Fo—c'D FIG PKG. SIZE PID NUMBER BOX HEIGHT 1 BAY 2975-9407 22" 2 BAY 2975-9408 40" 3 BAY 2975-9409 56" I BAY 2975-9410 22" 2 BAY 2975-9411 40" 3 BAY 2975-9412 56" 1 BAY 2975-9438 22 2 BAY 2975-9439 40" 3 BAY 2975-9440 56" 66" (TYPICAL, FOR 5 FOOT HEIGHT TO LCD DISPLAY CENTERLINE) CHART 5 17/32" WALL FLOOR FINISHED WALL SIDE WALL CLASS 'A' + + CLASS 'B' + + - - WIRES MUST BE CONNECTED SEPARATELY UNDER TERMINALS. A CONTINUOUS WIRE LOOP IS NOT ALLOWED. ONLY CLASS B IDNET, MAPNET OR DATA COMM. CABLE MAY BE T-TAPPED. IT MUST BE DONE IN A JUNCTION BOX WITH CABLE STRAIN RELIEF I.E.. CORD CLAMP/BUSHING AND TAPE WRAPPED AS SH�WN HERE STRIP THE INSULATED WIRES ABOUT 5/16" TO 3/8" FOR INSERTION INTO BOX -TYPE OR SCREW -CLAMP TERMINALS ON THE ADDRIESSABLE DEVICE. _---THE SHIELD/DRAIN IS NEVER CONNECTED TO THE DEVICE. lb TRIM THE BARE DRAIN TO ABOUT 1-1/2". JOIN THEM WITH AN ELECTRICAL CONNECTOR LISTED AND APPROVED FOR WIRE SPLICING. REFER TO FIGA FOR TYP. CONDUIT PENETRATION LOCATIONS 3 1/4" MIN. 24" 10" MAX. F 16 FOR SURFACE MOUNT USE 4 HOLES TO SECURE BACKBOX TO WALL BATTERY AREA (IF APPLICABLE) NO CONDUIT ENTRY OR WIRING IN THIS AREA EXAMPLE OF ADDITIONAL CABINET MOUNTING LOCATION CONDUIT FOR INTERNAL PANEL HARNESSES OR NPL WIRING. SECURE THE DRAIN WIRES INTO THE CONNECTOR APPROVED FOR THE PURPOSE. WIRES MUST BE TIGHT ENOUGH TO HOLD SECURELY AND NOT SLIP OUT OF THE CONNECTION. ENSURE BARE DRAINS ARE SECURED AND UNABLE TO MAKE EXTERNAL CONTACT. SEE NOTE 2 PID NUMBER BOX HEIGHT BOX LENGTH BOX DEPTH 2081-9280 12" 26 1/2- 12" 4081-9306 13 1/2" 27 7/8" 14 5/8" 4081-9308 13 1/2" 27 7/8" 14 5/8" DETECTOR LOCATION REQUIREMENTS FOR WALL SECTIONS NFPA 72 DEPTH OF WALL SECTION ABOVE DOOR FRAME MOUNTED CEILING MOUNTED DOOR SMOKE DETECTOR LISTED FOR FRAME d MOUNTING OR AS PART OF CLOSER SMOKE DETECTOR CEILING MOUNTED ASSEMBLY A B 100-300 mm 0 610 mm (0 t d 610mm or - 24 in.) 24 in,) �i� d max. 1.52 m (5 ft) ON BOTH SIDES d min. but not less OF DOORWAY DETECTOR OR DETECTOR CLOSER than 305 mm (12 in.) MOUNTED ON EITHER SIDE ONE DETECTOR MOUNTED ON EITHER SIDE C D 100-300 mm OVER 610 mm d2> 610mm c1l < 610mm (2 4 1 in.) d I < 61 Omm d2> 610 mm (2 4 i n.) (24 in.) (24 In.) (24 in.) ON ONE SIDE 4 --1 F_[�� _11 ONLY DETECTOR OR DETECTOR CLOSER 1.52 m (5 ft) max. MOUNTED ON HIGHER SIDE ONE DETECTOR MOUNTED ON HIGHER SIDE min. = d 2 E F o r o r OVER 610 mm d > 610mm (24 in.) (24 in.) d 100-300 mm ON BOTH SIDES 1.52 m (5 ft) max. 1.52 m (5 ft) max. DETECTOR OR DETECTOR CLOSER min. = d I -min. d MOUNTED ON EITHER SIDE TWO DETECTORS REQUIRED OVER 1524 mm G MIGHT REQUIRE ADDITIONAL DETECTORS (60 in.) END —OF —LINE RESISTOR CODES NOTE: REFER TO PANEL/MODULE AND DEVICE INSTALLATION INSTRUCTIONS FOR PROPER TERMINATIONS. * USE WITH RETROFIT OR HIGH CURRENT MODULE MODEL REFERENCE NUMBER OHMS 1ST BAND 2ND BAND 3RD BAND 4TH BAND 5TH BAND WATTS CIRCUIT TYPE FIRE ALARM PANEL/MODULE 4081-9001 733-892 2.2 K RED RED RED GOLD N/A 1/2 ANNUNCIATOR (4300) 4004, 4010 (TROUBLE) 4081 -9002 733-893 3.3K ORANGE ORANGE RED GOLD N/A 1 N.O, INITIATING PULL, SMOKE, HEAT, WATERFLOW, TAMPER, ETC. — 4004*, 4004R, 4005*, 4006, 4100, 4120, 4100U, ZAM'S 24 PT. 1/0 SWITCH SUPV. 4605-7401, 4100 SERIES 4081-9003 733-896 4.7 K YELLOW VIOLET RED GOLD N/A 1/2 CURRENT LIMITED N.C. INITIATING 4090-9001 IDNET IAM (EOLR) NOTIFICATION (DACT) 2080-9024 4081-9004 733-886 6.8K BLUE GREY RED GOLD N/A 1/2 N.O. INITIATING PULL, SMOKE, HEAT, WATERFLOW, TAMPER, ETC. 4004, 4005, 4090-9001 IDNET AM 2190-9173 MAPNETII 2 PT 1/0 4-20MA ZAM (TROUBLE) 4081 -9005 733-984 1.8K BROWN GREY RED GOLD N/A 1/2 CURRENT LIMITED N.C. INITIATING (IN LINE) 4090-9001 IDNET IAM 4081 -9006 733-890 560 n GREEN BLUE BROWN GOLD N/A 1 N.C. INITIATING (EOLR) 4005*, 4090-9001 IDNET IAM 4100, 41 OOU 4081-9007 733-891 1.2K BROWN RED RED GOLD N/A 1 N.C. INITIATING (EOLR) 4005 4081-9008 733-894 10K BROWN BLACK ORANGE GOLD N/A 1/2 NOTIFICATION 4004, 4005, 4006, 4008, 4009, 4010, 4100, 410OU 4081 -9009 733-912 20n RED BLACK BLACK GOLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT 1/0 4081-9010 733-973 1K BROWN BLACK RED GOLD N/A 1 N. C. INITIATING (ACROSS CONTACTS) 4005*, 4090-9001 IDNET IAM 24 PT. 1/0 (ACROSS CONTACTS) 4605-7401, 4100 SERIES CURRENT LIMITED N.C. INITIATING (IN SERIES WITH CONTACT) 4090-9001 IDNET IAM 4081-9011 733-974 100n BROWN BLACK BROWN GOLD N/A 112 ANNUNCIATOR (N2) 4006, 4008, 4010 4081-9012 733-985 22K RED RED ORANGE GOLD N/A 1/2 SPEAKER CIRCUIT 4003 4081-9013 734-086 4.99K YELLOW WHITE WH ITE BROWN BROWN 1/2 4081-9014 734-092 2.4K RED YELLOW RED GOLD N/A 1/2 N.C. INITIATING (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM 4081-9015 734-093 1.5K BROWN GREEN RED GOLD N/A 1/2 CURRENT LIMITED N.C. INITIATING (SECURITY MONITORING EOILR) 4090-9001 IDNET IAM 4081-9016 734-149 150K BROWN GREEN YELLOW GOLD N/A 1/2 4081-9017 734-171 3.9 K ORANGE WHITE RED GOLD N/A 1 4081-9018 734-168 10K BROWN BLACK ORANGE GOLD N/A 1 70VRMS CONSTANT SUPV. NACS 4100-1260 378-090 8.2K G RAY RED RED GOLD N/A 1/2 SECURITY MONITORING (EOLR) 4100, 41 OOU 378-046 5.6K GREEN BLUE RED GOLD N/A 1/2 N.O, SECURITY MON. (SERIES) 4100, 41 OOU 378-069 12K BROWN RED ORANGE GOLD N/A 1/2 N.C. SECURITY MON, (SHUNT) 4100, 410OU 4009 NAC PANEL, TYPICAL WIRING DETAIL IF OPTIONAL SHIELDS ARE USED FOR IDNet WIRING, FOLLOW THESE PRECAUTIONS. 4-M FROM PREV10US IDNet DEVICES 1. IF IDNet WIRING CONTINUES ON TO ANOTHER DEVICE, UK Ne A TAPE SHIELDS TOGETHER. DO NOT TERMINATE SHIELD AT 4009 IDNet. �M TO ADDITIONAL IDNet DEVICES 2. IF IDNet WIRING TERMINATES AT THE 4009, TAPE SHIELD. UK RETURN TO HOST IDNet CONTROL PANEL DO NOT TERMINATE SHIELD AT 4009 IDNet. IDNet CONTROLLER ADDRESS: TO NAC#:Vl DEVICES 0� V @ MIN 0% 0 tjtj11++ 0 0 == +_+_ E IDNET NAC 1 NAC 2 NAC 3 NAC 4 FSW2 11 1 a. 10 Ll H 1111 1,04" AAUX POWER POS IN Doo "P., PO Uff WRDMRE To INPUT 0 RE IN 0 R 0 PEr OUT MSIBE OS IN � 0 . 00co a POS OUT WRDNIRE RET IN INPUT 2 REr OUT AUDIBLE BATTERY 4009-9201 IDNet NAC EXTENDER 0 ADDIRM-RE NAC SYSTW 0 @ BATTERY BATTERY CONNECT A 12 AWG COPPER GROUND WIRE FROM SAFETY GROUND IN THE ELECTRICAL DISTRIBUTION PANEL TO THE 4009 SAFETY GROUND STUD. GROUND NEUTRAL CONNECT TO 120VAC 60HZ INPUT 3A MAX. r HOT 120V 4 _[TIIH.I�NAL PART OF r( -991 733 0071 Go 00 ;� P_ C? CID T:: CN C9 9" M co w co U, [-- L�j CN % % z 1.- 0 7% cn Uj LU oo 3 c:, R, C4 CO zi; 19 = C4 wmm LUco- �: co —1 z U- 6i =);�tg 4�_ c) > 12 C3 LU co Mn 0 U) > 0 LU >. Of 0 Uj F. 0 < 06 U-) 27. cy) 0 U) C) < 0 _j 0 LJJ _j --1 Lj_ < F- -n - cp 0 CD 0 0 ca _j = _j _j X — Uj of < < cq >- 0 FE M LO M 0 0- i C) LU Uj LL_ r-_ P�_j 0 0 0 cn LU M 0 — Uj 0 LU M co Ln_j F_ DRAWN BY: B. KNICKLE CHECKED BY: F. REINHART ISSUE DATE: 7/19/16 CURTIS ENGINEERING SERVICE, LLC - CA#31561 JOB #: 292415807 JAMES M. CURTIS, P.E. - PE#37912 29775 BAYHEAD ROAD PROJECT#: 1292:993523001 DADE CITY, FLORIDA 33523 SIMPLEXGRINNELL @ 2016 DEL EGA TED ENGINEER OF RECORD SYSTEM: Digitally signed C& Z/ 0� N 14F.-sargoo-'k is ! Z S 'r . %, by James Curt -%'- -S , - No. Date: OF 2016.0722 NA%. '09:32:29 -04 00 11111%% LARM SYSTEM SHEET: WIRING TYPICALS FA-701 w _j �e 0 z v 0 M 0 U) 9 CD CD c:) 04 LU U) 61 CD IN 04 x cl) DUCT DETECTOR/SENSOR INSTALLATION GUIDE PRE -INSTALLATION ROUTINES DUCT DETECTORS/SENSORS SHOULD BE INSTALLED IN A LOCATION OF RELATIVELY NON -TURBULENT AIR FLOW AND WITHIN THE INTENDED OPERATING VELOCITY RANGE OF 300-4000 FEET -PER -MINUTE (91 TO 1220 M/MIN.) SIMPLEX RECOMMENDS MEASUREMENTS OF AIR FLOW AND EXAMINATION OF ENGINEERING SPECIFICATIONS THAT DEFINE EXPECTED DUCT AIR VELOCITIES UNDER ALL CONDITIONS. THIS IS DONE TO DETERMINE IF A LOCATION IS SUITABLE FOR DUCT DETECTOR/SENSOR OPERATION, AN ALNOR INSTRUMENT CO. (CHICAGO) MODEL 6000P VELOMETER OR EQUIVALENT (NOT SUPPLIED) MAY BE USED TO CHECK THE DUCT AIR VELOCITY. INSTALLATION GUIDELINES 1. IT IS RECOMMENDED TO LOCATE DETECTORS/SENSORS A MINIMUM OF SIX DUCT WIDTHS DOWNSTREAM FROM BENDS OR INLETS. SUCH LOCATIONS ENSURE THAT AIR FLOW IS NON -TURBULENT AND THAT SMOKE IS PROPERLY MIXED WITH AIR IN THE DUCT FOR MAXIMUM DETECTOR/SENSOR EFFICIENCY. SEE FIGURES 1 AND 2. NOTE: INSTALLATION OF A DUCT DETECTOR/SENSOR TO A ROUND DUCT IS THE SAME AS SHOWN IN FIGURES 1 AND 2 AS LONG AS THE ROUND DUCT IS 18 INCHES OR LARGER (45.7 CM) IN DIAMETER. ;�j BEND OR OTHER OBSTRUCTION 6 DUCT WIDTIHS MINIMUKF" FIGURE 1. DUCT HOUSING PLACEMENT LOCATION OF BENDS OR INLETS RETURN A� INLET �6 DUCT WIDT�s -MINIMUM ­I FIGURE 2. DUCT HOUSING PLACEMENT LOCATION OF AIR RETURN INLET 2. LOCATE DUCT HOUSINGS SO THAT DAMPERS DO NOT RESTRICT AIR FLOW AT THE DETECTOR/SENSOR LOCATION. SEE FIGURE 3. 3. LOCATE AIR DUCT DETECTORS/SENSORS ON THE RETURN OR SUPPLY DUCT OF THE EQUIPMENT'S AIR HANDLING SYSTEM. HOWEVER, DETECTORS/SENSORS SHOULD NOT BE INSTALLED IN THE RETURN AIR DAMPER BRANCH. SEE FIGURE 3. 4. LOCATE AIR DUCT DETECTORS/SENSORS ON BRANCH LINES IF CLOSE IDENTIFICATION OF THE ALARM SOURCE IS REQUIRED. 5. LOCATE AIR DUCT DETECTORS/SENSORS ON THE DOWNSTREAM SIDE OF FILTERS TO SENSE FIRE IN FILTERS. HOWEVER, SHOULD THE FILTERS BLOCK, SUFFICIENT AIR FLOW MAY NOT BE AVAILABLE FOR PROPER AIR DUCT DETECTOR/SENSOR OPERATION. SEE FIGURE 3. 6. WHENEVER POSSIBLE, LOCATE AIR DUCT DETECTORS/SENSORS WHERE THEY CAN BE CONVENIENTLY OBSERVED AND READILY SERVICED. DETECTOR/SENSOR EXHAUST RETURN AIR EXHAUST DAMPER DO NOT WCATE DETECTORYSENSOR HERE RETURN �IR DAMPER I FRESH AIR INTAKE-F_ 11 1 - SUPPLY AIR DO NOT LOCATE FILTER K_17 DETECTOR/SENSOR HEVE BAN \-'DETECTOR/SENSOR OKAY FIGURE 3. DUCT HOUSING PLACEMENT - LOCATION OF DAMPERS 7. LOCATE THE AIR DUCT DETECTORS/SENSORS IN RETURN AIR DUCTS AHEAD OF MIXING AREAS. 8. DO NOT LOCATE AIR DUCT DETECTORS/SENSORS NEXT TO OUTSIDE AIR INLETS UNLESS YOU WANT TO MONITOR SMOKE ENTRY TO THE HANDLING SYSTEM FROM AN ADJACENT AREA. 9. LOCATE AIR DUCT DETECTORS/SENSORS UPSTREAM OF AIR HUMIDIFIERS AND COOLING COILS. DUCT DETECTOR/SENSOR INSTALLATION 1. TAPE THE TEMPLATE (SUPPLIED) ON THE DUCT SURFACE AS SHOWN IN FIGURE 4. NOTE: DO NOT POSITION THE TEMPLATE WITH EDGES ANGLED WITH RESPECT TO AIR FLOW DIRECTION (FIGURE 4). 2. DRILL TWO 1 1/4 INCH (31.75 MM) HOLES (MARKED "A") AS LOCATED BY THE TEMPLATE. REMOVE TEMPLATE AFTER HOLES HAVE BEEN DRILLED. 3. IF THE DUCT IS MORE THAN 3 FEET (0.9 M) WIDE, THEN PUNCH A 1-INCH (25.4 MM) HOLE IN THE DUCT WALL DIRECTLY OPPOSITE THE UPSTREAM 1 1/4 INCH (31.75 MM) HOLE. SEE FIGURE 5. THIS HOLE IS USED TO SUPPORT THE INLET TUBE. FOR DUCT WIDTHS FOR DUCT WIDTHS 3 FEET TO 95 INCHES 12 INCHES TO 3 FEET INSERT RUBBER PLUG THIS END OF INLET TUBE TUBE SUPPORT HOLE TOP VIEW FOR DUCTS MORE THAN 3 FEET WIDE OR CUT EXHAUST TUBE OR RE FLOW CTI ERN i TUB 0 T i INLET TUBE HOLE AIR FIL TO 1h OF DUCT DIRECTI WIDTH WHEN WIDTH FACE UPSTREAM N OF AIR FLOW INLET T , UBE HOLES IS LESS THAN 24" I"T",", FACE UPSTREAM EXHAUST TUBE OF AIR FLOW EXHAUST TUBE DO NOT INSERT RUBBER PLUG DO NOT INSERT RUBBER PLUG NOTE: AIRFLOW CAN BE IN EITHER DIRECTION. MAKE SURE THE INLET TUBE HOLES FACE UPSTREAM OF AIR FLOW. FIGURE 5. INLET TUBE ORIENTATION TAB SEE NOTE 1--_Z-o\ INLET U TUBE RETAINER 0 _Vy BRACKET - NOTES: 1. THE TAB ON THE INLET TUBE RETAINER BRACKET INDICATES THE INLET HOLE SIDE OF THE PIPE. 2. THE INLET TUBE MUST BE INSTALLED THROUGH THE HOLE IN THE HOUSING CORNER NEXT TO THE SMOKE PORT/AIR FLOW TEST HOLES. EXHAUST TUBE INLET TUBE HOLES FACE UPSTREAM OF AIR FLOW 0 0 0 SEE NOTE 2-`�� INLET TUBE FIGURE 6. INLET TUBE INSTALLATION TABLE 3. INLET TUBE SELECTION IR FLOW AIR FLOW R ECTION D I R ECTI O!N OVERALL DUCT WIDTH TUBE REQUIRED TUBE TYPE SUGGESTED TOTAL LENGTH 12" (30 CM) 2098-9796 13" (33.02. CM) 1h INCH (1.27 CP) LONGER THAN DUCT WIDTH HORIZONTAL DUCTS OVER 13" HIGH HORIZONTAL DUCTS UNDER 13" HIGH VERTICAL OR �NCX AIR FLOW DUCTS DIRECTION 4*�14 'All. 1110jN NEVER MOUNT AT AN ANGLE WITH RESPECT TO AIR FLOW 13" (33.02 CM) TO 23" (58 CM) 2098-9804 24" ('60.96 CM) 1h INCH (1.27 CM) LONGER THAN DUCT WIDTH 24" (60 CM) TO 46" (1,16 M) 2098-9797 49" (125.46 CM) 2" (5.8 CM) LONGER THAN DUCT WIDTH 46" (1. 16 M) TO 71 " (1.8 M) 2098-9798 73" (1.85 M) 2" (5.8 CM) LONGER THAN DUCT WIDTH 71 " (1.8 M) TO 1 95" (2.4 M) 2098-9799 97" (2.45 M) 2" (5.8 CM) LONGER THAN DUCT WIDTH FIGURE 4. TEMPLATE POSITIONING INLET TUBE SELECTION 4. INLET TUBES SHOULD BE SELECTED AND CUT TO LENGTH AS SPECIFIED IN TABLE 3. AFTER TRIMMING THE INLET TUBE OPPOSITE THE SLOT, TAP RUBBER PLUG (SUPPLIED) INTO THE TRIMMED END. SEE FIGURE 5. REFER TO INSTALLATION INSTRUCTION DOCUMENT 574-776 FOR MORE DETAILED INFORMATION. AIR PRODUCTS PAM-SD 24VDC POLARIZED RELAY MODULE (SIMPLEX 4098-9843) SP FIC TIONS: • POWER REQUIREMENTS: 0.015 AMP @ 24VDC (17 VDC TO 32 VDC) • RELAY: U.L. RECOGNIZED SPOT • CONTACT RATING: 7 AMPS @ 120VAC & 28 VDC 250 MICRO AMPS @ 5 VDC • AMBIENT TEMPERATURE: -50' F TO 85 'F (-50'C TO 85*C) • APPROVALS: UNDERWRITERS LABORATORIES LISTED • 12" 18 AWG WIRE LEADS • DIMENSIONS: 1-1/2"H X 1 7/8" W X 13/16" D (38.1mm H X 47.625mm W X 20.638mm D) FEATURES: * SINGLE SPDT RELAY * DOUBLE -SIDED ADHESIVE TAPE * MOUNTING SCREW * 5 WIRE NUTS COVER PLATE SUPPLIED BY CONTRACTO ANY SINGLE GANG BOX SUPPLIED BY CONTRACTOR 10,0 AMP CONTACTS ED 24VDC @ 0.015A (18 VDC TO 32 VDC) PRODUCT INFORMATION 4090-9001 IDNET SLC, SUPERVISED ADDRESSABLE INPUT MODULE (AIM) FEATURES: UL LISTED - ADDRESSABLE COMMUNICATIONS SUPPLY BOTH DATA AND POWER TO PROVIDE: - SUPERVISED STYLE B MONITORING OF NORMALLY OPEN DRY CONTACTS. - COMMUNICATIONS WIRING USING ONE TWISTED, SHIELDED WIRE PAIR. - COMPATIBLE WITH SIMPLEX ADDRESSABLE FIRE ALARM CONTROL PANELS. . COMPACT, SEALED CONSTRUCTION: - ALLOWS MOUNTING IN A SINGLE GANG BOX - REDUCES DUST INFILTRATION - PROVIDES CURRENT LIMITED MONITORING - TO MONITOR TAMPER SWITCH (SUPERVISORY) AND 4090-9810 BRACKET WATER FLOW SWITCH (ALARM) ON SAME CIRCUIT REQUIRED WHEN USI� - REQUIRES ONLY ONE ADDRESSABLE POINT THE SIMPLEX TRIM F 1� >G TES �TES SELECTABLE LATCHING OPERATION OPTIONAL WHEN USING MONITORS MOMENTARY CONTACT CLOSURES SUCH AS A CONTRACTOR SUPPLIED BACK BOX COVER OPTIONS; SINGLE GANG COVER RATE -OF RISE HEAT DETECTORS SEMI -FLUSH TRIM PLATE 4090-9806 (SHOWN) SPECIFICATIONS: WITH LIGHT PIPE FOR LED VIEWING - WIRE CONNECTIONS: SCREW TERMINALS FOR IN/OUT WIRING SURFACE TRIM PLATE 4090-9807 FOR WIRE FROM #18 TO #14 AWG, WITH LIGHT PIPE FOR LED VIEWING�� SINGLE GANG COVER W1 2 6/32 - DIMENSIONS: 1 9/16" X 1 3/4" X 1 1/4" FLATHEAD SCREWS - TEMPERATURE RANGE: 32' F TO 158' F (0' C TO 70' C) (SUPPLIED BY CONTRACTOR) F - HUMIDITY: UP TO 93% RH AT 100* F * SUPERVISION RESISTOR: 6.8kn 1/2W, (SUPPLIED) SIMPLEX PART NO. 733-886 - RESISTOR FOR CURRENT LIMITED OPERATION: 4.7kn 1/2W, WITH A 1.8kn 1/2W - INPUT REQUIREMENTS: N ORMALLY OPEN, DRY CONTACTS - HOUSING MATERIAL: BLACK THERMOPLASTIC DESCRIPTION: THE 4090-9001 IS AN ADDRESSABLE INPUT MODULE (AIM) WITH POWER AND COMMUNICATIONS SUPPLIED BY A TWO WIRE ADDRESSABLE CIRCUIT. IT PROVIDES LOCATION SPECIFIC ADDRESSABILITY TO A SINGLE INITIATING DEVICE (SUCH AS SINGLE STATION SMOKE TECTOR ALARM CONTACTS OR HEAT DETECTOR CONTACTS) OR DE MULTIPLE DEVICES AT THE SAME LOCATION BY MONITORING NORMALLY OPEN, DRY CONTACTS AND THE WIRING TO AN END -OF -LINE RESISTOR. CLOSURE OF THE MONITORED CONTACTS INITIATES AN ALARM OR OTHER RESPONSE AS PROGRAMMED AT THE FIRE ALARM CONTROL PANEL. AN OPEN IN THE MONITORED CIRCUIT WIRING WILL CAUSE A TROUBLE TO BE REPORTED. IF THE INITIATING DEVICE CONTACTS ARE MOMENTARY, SUCH AS FROM A RATE -OF -RISE HEAT DETECTOR, ENABLING THE LATCH FEATURE WILL MAINTAIN THE ALARM CONDITION UNTIL THE SYSTEM IS RESET. FOR APPLICATIONS WHERE THE CONTACT CLOSURE LATCHES, OR IF ITS CONDITION NEEDS TO BE TRACKED AT THE CONTROL PANEL T- NON-LATCHING OPERATION MAY BE ENABLED. WIRING NOTES: 1 . ALL WIRING TO COMPLY WITH LOCAL CODE. 2. CONDUCTORS MUST TEST FREE OF ALL GROUNDS. 3. ONLY N.C. DRY CONTACTS ARE ALLOWED. 4. MAXIMUM WIRE LENGTH (NO, 18 AWG) IS 400 FT. W/2081-9044 OVER VOLTAGE PROTECTORS OR 400 FT. W/O PROTECTORS. 5. A MAXIMUM QUANTITY OF DEVICES PER CIRCUIT: CONTROL PANEL MODULE DEPENDENT 6. IF SHIELD IS PRESENT, CONNECT TO THE OUTGOING IDNet SHIELD TO PROVIDE A CONTINUOUS SHIELD OVER THE LENGTH OF THE FERMINED BY AHJ. IDNet CHANNEL. METHOD OF SPLICE DE 7. REFER TO INSTALLATION INSTRUCTIONS 574-331. 8. MAXIMUM ALLOWABLE LINE RUN FROM THE F.A.C.P. TO THE FARTHEST DEVICE, NOT TO EXCEED 2500 FEET. 9. MAXIMUM TOTAL WIRE �INCLUDING ALL T-TAPS) FROM THE FIRE ALARM CONTROL ANEL 10. FOR STYLE 6 CIRCUIT WIRING IT IS RECOMMENDED THAT THE PRIMARY (D AND THE BACK-UP (Z LINES BE IN SEPARATE WIRE RUNS AND IN COMPLIANCE WITH LOCAL REQUIREMENTS. 11. REFER TO FIELD WIRING DIAGRAM 842-073 FROM UL-USTE SHIELD- F.A.C.P. OR PREVIOUS DNet/MAPNET + - R �,LU DEVICE DNet/MAPNET B ill P SENSING OPERATION: PRIMARY IDNet/MAPNET SLC LINES SUPERVISED INPUT: N M N - 4090-9001 AIM WITH T-SENSE CAPABILITY HAS A SUPERVISED INPUT THAT MONITORS FOR CONTINUITY TO AN END -OF -LINE RESISTOR AND CAN DIFFERENTIATE BETWEEN A SHORT CIRCUIT CONTACT CLOSURE AND A CURRENT LIMITED CONTACT CLOSURE. FOUR STATE OPERATION: - NORMAL IS WHEN ALL CONTACTS ARE OPEN AND THERE IS CONTINUITY TO THE END -OF -LINE RESISTOR. - OPEN IS WHEN CONTINUITY DOES NOT EXIST TO THE END -OF -LINE RESISTOR, CAUSING A TROUBLE CONDITION. - SHORT, INDICATES THAT A CONTACT HAS CLOSED THAT IS DIRECTLY CONNECTED TO THE INPUT CIRCUIT. - CURRENT LIMITED INDICATES THAT A CONTACT HAS CLOSED BEYOND A SERIES CONNECTED CURRENT LIMITING RESISTOR. THIS OPERATION ALLOWS DIFFERENTIATION BETWEEN TWO DIFFERENT CONTACT733-886 TYPES DUE TO THEIR WIRING LOCATION, AND REPORTING AS A SINGLE IDNET ADDRESSABLE POINT TO A 410OU FIRE ALARM CONTROL PANEL. 733-886 (6.8K 1/2W) 111[ 4090-900, "wo 'IT In R4-iN UATE coo[. il I n-affin. 71001 OPTIONAL SHIELD UL LISTED SINGLE GANG ELECTRICAL BOX (2 1/8" MIN. DEPTH) (SUPPLIED BY CONTRACTOR) 0 ADDRESS DIP SWITCHES UNDER RE -SEALABLE LABEL SEE INSTALLATION INSTRUCTIONS (574-331) FOR SETTINGS TO ADDITIONAL S - SHIELD DEVICES OR RETURN R - + IDNet/MAPNET TO FIRE ALARM CONTROL PANELFOR B- - IDNet/MAPNET STYLE 6 SYSTEM APPLICATION (2) 16 _121 SECONDARY IDNet/MAPNET SLC LINES 1 E E Ifl M 733-886 (6.8K 1/2W) 4098-9756 ADDRESSABLE ANALOG 4-WIRE DUCT SENSOR MAPNET II/IDNet SLC WITH 24VDC RELAY PRODUCT INFORMATION DUCT DETECTOR SELECTION CHART A S: COMPACT AIR DUCT SENSOR HOUSING WITH CLEAR COVER TO MONITOR FOR THE PRESENCE OF SMOKE INCLUDES FACTORY INSTALL TRUEALARM PHOTOELECTRIC SMOKE DETECTOR AND FEATURES: - INDIVIDUAL SENSOR INFORMATION PROCESSED BY THE HOST CONTROL PANEL TO DETERMINE SENSOR STATUS - DIGITAL TRANSMISSION OF ANALOG SENSOR VALUES VIA M M - PROGRAMMABLE SENSITIVITY CONSISTENT ACCURACY ENVIRONMENTAL COMPENS&ION STATUS TESTING, AND MONITORING OF SENSOR DIRT ACCUMULATION MODEL: - DUCT SENSOR HOUSING WITH SUPERVISED OUTPUT FOR ,I,, Tp, r mr-Tr nri ­� Mrn I I In 17� I rn A I All I � 1111 iviu-11 - 1-viv- ni-1- - - �IRELAYS ARE UNDER PAN L CONTROL AND CAN BE CTIVATED MANUALLY OR BY A SEPARATE ALARM/INPUT) GENERAL FEATURES: UL LISTED TO STANDARD 268A CLEAR COVER ALLOWS VISUAL INSPECTION TEST PORTS PROVIDE FUNCTIONAL SMOKE TESTING ACCESS WITH COVER IN PLACE MOUNTS TO RECTANGULAR DUCTS OR ROUND DUCTS (MINIMUM SIZE 8" SQUARE OR 18" DIAMETER) MAGNETIC TEST FEATURE FOR ALARM INITIATION AT HOUSING OPTIONAL WEATHERPROOF ENCLOSURE IS AVAILABLE SEPARATELY (REFER TO DATA SHEET S4098-0032) DIAGNOSTIC LEDS (ON INTERFACE BOARD): - RED ALARM TROUBLE LED FOR SENSOR STATUS AND COMMUNICA�IONS POLLING DISPLAY - YELLOW LED FOR OPEN OR SHORTED TROUBLE INDICATION FOR DUCT WIDTHS FOR DUCT WIDTHS OF SUPERVISED RELAY CONTROL 2098-9808 2098-9806 3' TO 95" 8" TO 3' SAMPLING TUBES (ORDERED SEPARATELY): AVAILABLE IN MULTIPLE LENGTHS TO MATCH DUCT SIZE REMOTE STATUS/ALARM TEST STATION INSTALLED AND SERVICED WITH HOUSING IN PLACE INDICATOR REWE MODULE OPTIONS (ORDERED SEPARATELY): - RED STATUS/ALARM LED (2098-9808) (OPTIONAL) - TEST STATION WITH LED (2098-9806) 80' 2 .. TN'DICATOR - RELAYS USED (4098-9843) ALARM SPECIFICATIONS: RE�DM ALA[ GENERAL SPECIFICATIONS LED (f DUCT SMOKE SENSOR HOUSING WITH PHOTOELECTRIC SENSOR MODEL DESCRIPTION ___77MFA71BILI7 4098-9756 DUCT HOUSING WITH SUPERVISED MULTIPLE RELAY CONTRO FSOR Up TO 15, 4098-9843 RELAYSR�QRDERED SEPARATELY), RE RE SEPARATE 24 VDC FIRE ALA POWER AND RELAY ND-VFI- RESISTOR �SIMPLEX FIRE ALARM CONTROL MODELS 4008, 4010, 4020, 4100, AND 4120. REMOTE LED INDICATOR AND TEST STATION, SELECT ONE IF REQUIRED M L F-2098-9808 RED LED STATUS INDICATOR U,SE SINGLE GANG BOX, 3 H X 2" W X 2" D (76 mm X 51 mm X 51 mm ��8-9806 F TEST STATION WITH KEYSWITCH AND RED LED STATUS TURNING SWITCH TO TEST INITIATES ALARM FOR SYSTEM TESTIN AIR VELOCITY RANGE (LINEAR FT/MIN) 300 TO 4000 FT/min (91 TO 1220 m/min) SENSOR SENSITIVITY RANGE 0.2% TO 3.7% PER FOOT OF OBSCURATION, SELECTABLE AT HOST CONTROL PANEL UL LISTED TEMPERATURE RANGE 32' F TO 100' F (0' C TO 38. C OPERATING TEMPERATURE RANGE 32- F TO 122- F (0' C TO 50' C) STORAGE TEMPERATURE RANGE 0' F TO 140- F (-18' C TO 60- C) HUMIDITY RANGE 10% TO 95% RH, NON -CONDENSING HOUSING COLOR BLACK BASE WITH CLEAR COVER WIRING CONNECTIONS TERMINAL BLOCKS, 18 TO 12 AWC REMOTE STATUS7T97M _LED AND TEST STATION WITH REMOTE STATUS/ALARM LED REMOTE ALARM LED CURRENT 1.2 mA NO IMPACT -TO ALARM CURRENT (2098-9808 OR 209'8-9806) TEST STATION KEYSWITCH CURRENT 3.3 mA, NO IMPACT TO ALARM CURRENT (2098-9806) REMOTE ALARM LED AND TEST STATION DISTANCE 250 FF. (76m) MAXIMUM ADDRESSABLE OPERATION DATA COMMUNICATIONS MAPNETII OR IDNET SLC COMMUNICATION, AUTO -SELECT I ADDRESS PER HOUSING, PROVIDES OPERATING POWER �TO MODEL 4098-9755 MODEL 4098-9756 WITH SUPERVISED MULTIPLE RELAY CONTROL, REQUIRES SEPARATE FUSED 24 VDC FROM FIRE ALARM POWER SUPPLY INPUT VOLTAGE 17-32 VDC (24 VDC NOMINAL) STANDBY CURRENT 3 mA @ 24 VDC ALARM CURRENT 15 mA @ 24 VDC, ADD 15 mA ADDITIONAL FOR EACH . 40qR-qP,4� RELAY 4098-9843 RELAY OUTPUT RATINGS, SINGLE FORM C COIL CURRENT 15 mA 0 24-VDC UP TO 15 MAX. PER RELAY C-0­NT-­RTL OUTPUT RELAY CONTACTS, RESISTIVE RATINGS- 7 A @ 28 VDC & 120 VAC: 250 uA @ 5 VDC LOCATION DISTANCE 500 FT. (152m) MAX. TO RELAY COILS, RELAY M JST­B E WITHIN 3 FT. Cfm) OF DEVICE BEING CONTROLLED PER NFPA 72, SECTION 3-9.2.1 PRODUCT INFORMATION FEATURES: - ILL LISTED * CALIFORNIA STATE FIRE MARSHAL LISTING NUMBERS: 2908-9806 ALARM INDICATOR 7300-0026:150 o MOUNTING: FLUSH - FINISH: CHROME OR STAINLESS STEEL SPECIFICATIONS: . ALARM CURRENT: 2.8 mA - DIMENSIONS OF BOX: 2 "W X 3"H X 2"D DESCRIPTION: SEE NOI 3, 4 TUBE SUPPORT HOLE SHALL BE USED FOR DUCTS MORE THAN 3 FEET WIDE INSERT RUBBER PLUG X A ST TUBE CUT TO 1/2 OF DUCT WHEN < 24 DO NOT INSERT RUBBER PLUG 4098-9756 4-WIRE DUCT SENSOR SW2 1 o oMr= 2 z 3 4 5 6 7 173M 8 E=lw ADDRESS SWITCH TB1F1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1� (? ? ? 9 (� (? (? (� (� ? (P 9 � ? I 'LE q �� I TEST I MAP +I MAP I +24VI 24C I 'ALM- . �-j T F (OPTIONAL) 2098-9806 REMOTE ALARM INDICATOR/ KEYSWITCH RED ALARM LED TEST I SEE NOTES 3,4 4098-9756 4-WIRE DUCT SENSOR SW21 2 z 3 =w 4 1 5 6 7 8 E=3w ADDRESS SWITCH 1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 y y y y y y y y Y,? - _ +24VI TEST I MA P +,MAP,-, I -ALM- '24C _T IRED�L BILK �REI� B tt TO OTHER MAPNETII/ IDNET SLC DEVICES JSTED �01_ PANEL SIMPLEX 4010, 4020 4008, 4100+ OR 4120 SEE NOTE 2 OR RETURN TO FACP MAPNET I/IDNet H WHIO 1 2 W 10K EOL IELD FOR STYLE 6 SLC SHIELD BLU­-c- RESISTOR SH HT (OPTIONAL) TOTE 1 4-098-9843 PAM SD YEL-N..C. 4081-9008 - POWER CIRCUIT + RE- ORG-N.O. C- BLU­- 4098-9843 24 VDC + 1/2 W 10K EOL N.C�YEL- PAM-SD 0 0 RE RESISTOR N.O�ORG- RELAY WIRING NOTES: + k_� WH T W'T'* LAY C- 3L C_YE O_ 0 RE RED-* 4081-9008 7r�NR 1. DUCT SENSOR WIRING IS1 2 TO 18 AWG. 2. MAXIMUM QUANTITY OF DEVICES PER CIRCUIT IS 127 FOR 4020, FIRE 4100+, OR 4120, AND 250 FOR THE 4010 PANEL SMOKE AIR DAMPER HANDLING IRING. LH IT 3. THE 2098-9806 AND 2098-9808 ARE POLARIZED, OBSERVE COLOR -CODED W UN 4. MAXIMUM WIRE LENGTH TO TEST TERMINALS AND REMOTE LED IS 250 FEET. <S> 4098-9843 PAM-SD RELAY (AIR PRODUCTS & CONTROL LIMITED) ARE RATED AT 7 AMPS 28 VDC/10 AMPS @ 115 VAC. MAXIMUM WIRE LENGTH TO PAM-SD RELAYS IS FSD POWER AHU POWER 500 FF. (15 PAM-SD RELAYS MAX.). WIRING FROM THE RELAY TO THE (BY OTHERS) DEVICE IT IS CONTROLLING SHOULD BE NO MORE THAN 3 FT. (PER NFPA 72), (BY OTHERS) 2098-9806 REMOTE ALARM INDICATOR/KEY SWITCH 2098-9806 REMOTE TEST STATION, PROVIDES A REMOTE RED ALARM LED STATUS INDICATOR AND A REMOTE TEST KEY ACTIVATED SWITCH MOUNTED ON A SINGLE GANG STAINLESS STEEL PLATE. THE LED WILL PULSE TO INDICATE NORMAL OPERATION OF THE DUCT DETECTOR AND WILL ENERGIZE CONTINUOUS WHEN IN ALARM OR IN TROUBLE. (THE EXACT STATUS OF THE SENSOR WILL BE DISPLAYED AT THE FIRE ALARM CONTROL PANEL.) TURNING THE TEST SWITCH TO "FEST" WILL INITIATE AN ALARM AND ALLOW THE RESULTING SYSTEM RESPONSES TO BE VERIFIED. WIRING: • MINIMUM 18 AWG OR TO LOC�L CODE. • CONDUCTORS MUST TEST FREE OF ALL GROUNDS. • REMOTE ALARM LED IS POLARIZED, OBSERVE COLOR CODED WIRING. • ONE INDICATOR MAY BE INSTALLED PER DETECTOR. CONNECT TO REMOTE ALARM LED OUTPUT OF APPROPRIATE INITIATING DEVICES CONNECT TO REMOTE TEST SWITCH INPUT ON APPROPRIATE INITIATING DEVICES FLUSH MOUNTING 2098-9806 BACK VIEW STANDARD SINGLE GANG BOX 2" X 3" MINIMUM DEPTH 2" SUPPLIED BY CONTRACTOR 4090-9002 IDNet SLC, INDIVIDUAL ADDRESSABLE OUTPUT MODULE RELAY (AOM) PRODUCT INFORMATION FEATURES: - UL LISTED - A SINGLE ADDRESSABLE POINT BOTH CONTROLS A 2A FORM "C" CONTACT AND TRACKS ITS STATUS - COMPATIBLE WITH SIMPLEX MODEL 4010 AND 4100 ADDRESSABLE FIRE ALARM CONTROL PANEL - LATCHING RELAY DESIGN ALLOWS DATA AND POWER TO BE BOTH SUPPLIED BY IDNet COMMUNICATIONS - COMPACT, SEALED CONSTRUCTION: - SCREW TERMINALS FOR WIRING CONNECTIONS - REDUCES DUST INFILTRATION SPECIFICATIONS: - RELAY IAM POWER: SUPPLIED BY IDNet COMMUNICATIONS - RELAY IAM CONTACTS (FORM "C", SPDT) - POWER LIMITED RATING: 2A @ 24VDC, TRANSIENT SUPPRESSED LOADS, 1A @ 24VDC FOR INDUCTIVE LOADS - NON POWER LIMITED RATING: 1/2A @ 24VAC, TRANSIENT SUPPRESSED LOADS, 1A @ 24 VDC FOR INDUCTIVE LOADS - WIRE CONNECTIONS: SCREW TERMINALS FOR IN/OUT WIRING, #18 TO #14 AWG WIRE o COMPATIBLE WITH SIMPLEX 2081-9044 OVER VOLTAGE PROTECTORS - DIMENSIONS: 4 1/8"H x 4 1/8"W x 1 3/8"D (105mm x 105mm x 35mm) - HOUSING MATERIAL: BLACK THERMOPLASTIC - MOUNTING PLATE MATERIAL: SHEET METAL, GALVANIZED - TEMPERATURE RANGE: 32* F TO 120* F (0' C TO 49- C) INTENDED FOR INDOOR OPERATION o HUMIDITY RANGE UP TO 93% RH AT 100' F (38' C) DESCRIPTION: IDNet SLC RELAY MODULES ALLOW THE SIMPLEX FIRE ALARM CONTROL PANEL TO CONTROL A REMOTELY LOCATED FORM "C" CONTACT USING IDNet ADDRESSABLE COMMUNICATIONS FOR BOTH DATA AND POWER. TYPICAL APPLICATIONS WOULD BE FOR SWITCHING LOCAL POWER FOR CONTROL FUNCTIONS SUCH AS ELEVATOR CAPTURE, OR CONTROL OF HVAC COMPONENTS, PRESSURIZATION FANS, DAMPERS, ETC. RELAY STATUS IS ALSO COMMUNICATED REQUIRING ONLY ONE DEVICE ADDRESS. WIRING NOTES: 1 . IDNet LINES ARE TO BE #18 AWG TWISTED PAIR (CONSULT SG SALES ENGINEERING FOR EXCEPTIONS). 2. MAXIMUM ALLOWABLE LINE RUN, FROM THE F.A.C.P. TO THE FARTHEST DEVICE, NOT TO EXCEED 2500 FEET. 3. MAXIMUM QUANTITY OF DEVICES PER CIRCUIT: CONTROL PANEL MODULE DEPENDENT 4. CONTRACTOR WIRING TO RELAY CONTACTS IS UNSUPERVISED. USE #14 AWG WIRE TO LOCAL CODE. 5. RELAY CONTACTS RATED 2A, 24VDC (1A FOR INDUCTIVE LOAD) RELAY CONTACTS RATED 0.5A 120VAC (NON POWER LIMITED) FOR POWER -LIMITED OPERATION, POWER MUST BE PROVIDED FROM FACP OR POWER -LIMITED POWER SUPPLY LISTED FOR FIRE PROTECTIVE SIGNALING USE. 6. SEE INSTALLATION INSTRUCTIONS 574-184. 7. IF SHIELD IS PRESENT, CONNECT TO THE OUTGOING IDNet SHIELD TO PROVIDE A CONTINUOUS SHIELD OVER THE LENGTH OF THE IDNet CHANNEL. METHOD OF SPLICE DETERMINED BY AHJ. 8. WHEN CONNECTED TO A NON POWER -LIMITED SOURCE, THE WIRING MUST MAINTAIN A MINIMUM 1/4 INCH SEPARATION FROM IDNet WIRING. 9. WHEN USED WITH NON POWER -LIMITED SOURCE, THE "POWER LIMITED WIRING" INDICATION ON THE DEVICE LABEL MUST BE OBLITERATED. 10. WHEN BOTH POWER -LIMITED AND NON POWER -LIMITED SOURCES ARE PRESENT, USE TYPE FPL, FPLR OR FPLP POWER LIMITED CABLE FOR POWER -LIMITED CIRCUITS. 11. MAXIMUM TOTAL WIRE (INCLUDING ALL T-TAPS) ON CIRCUIT, FROM THE F.A.C.P. NOT TO EXCEED 10,000 FEET OR .58uF. (CLASS B ONLY) 12. REFER TO FIELD WIRING DIAGRAM 842-073 V FCWI G 2-GANG BACK BOX COVER SUPPLIED BY CONTRACTOR r -on, Q) 4" SQUARE X 2 1/8" DEEP BOX SUPPLIED BY CONTRACTOR A41 Is 51 DI NORMALLY CLOSED (N.C.) COMMON - - - F_ . 11 11 mo NORMALLY OPEN (N.O.) NORMALLY OPEN (N.O.) F F 111111.1111L we F_ MH m: F_ NOT USED NOT USED I I I 1 0 0 0 I L - - - - - - - - - - - - - - - - - L- - - - - - - - - - - - - - - - - - PRIMARY SECONDARY IDNet SLC LINES IDNet SLC LIN 91 [21 M 0 OPTIONAL SHIELD (c�� S S RI 18 R I I B + + FROM PREVIOUS SLC DEVICE IDNet SLC OR F.A.C.P. TO F.A.C.P. 341 [51 MI F91 NORMALLY CLOSED (N.C.) COMMON ADDRESS SETTING UNDER RE -SEALABLE LABEL CURTIS ENGINEERING SERVICE, LLC - CA#31561 JAMES M. CURTIS, P.E. - PE#37912 29775 BAYHEAD ROAD DADE CITY, FLORIDA 33523 DEL EGA TED ENGINEER OF RECORD Digitally signed x !; �\� 0 M: ! 4 ///, N , _!�j �A, ;ot by James Curtis �000_ No. Date: dop - - OF 2016.07.22 wwo, N - - - of%LOR om '09:33:25 -04'00 0111111%% I 04 C> CID 00 4 1­ it C? lov c14 C9 cp cl) ce) co CID a- U_ a qk LU C-4 LU co 0 Z� c:, C6 Fn - to CM4 w to, A Ei LLJ c,) - -1 co U_ 6i ,:If 2 c=) d- > CDMW Ln Lo Lu in cn '7" 0 U) I > 0 2-7 Uj ry 0 Uj 0 06 0 C/) 0 U) X (If LU o 0 I-_ a_ co LU LU cj 0 --I w Nd =) of co < ce) cy) C) 0 LU _j n -1 (now 0 fn _j < o >- o!f (=:) M: o U-) 0- _j (::) LU LL t*-- P114 B. KNICKLE DRAWN BY. CHECKED BY: F. REINHART ISSUE DATE: 7119/16 I I JOB #: 292415807 PROJECT#.. 1 292:993523001 SIMPLEXGRINNELL @ 2016 SYSTEM: FIRE ALARM SYSTEM SHEET: WIRING TYPICALS FA-702 _o E 8 _o _y LLJ _j v 0 z v 0 Lu cn U) CD �q C14 CD c:) ��j C14 uj F_ cf) cn C14 �r x m c:) c') PRODUCT INFORMATION 4099-9004 SINGLE ACTION IDNet SLC ADDRESSABLE MANUAL STATION 4" SQUARE x 2 1�8" DEEP BOX SINGLE GANG EXTENSION RING 3/4" (RA 0 NO. 231 OR 232) FEATURES: MOUNTING INSTRUCTIONS: CONDUIT (RACO NO. 773) OR (RACO NO. 500) KNOCKOUTS FOR 3/4 SIN GLE GANG SWITCH BOX SUPPLIED BY CONTRACTOR ILL, ULC LISTED 1. COVER & BACKPLATE COME ASSEMBLED. TOP AND BOTTOM OF BOX 2 1/2" DEEP SINGLE ACTION, IDNet SLC ADDRESSABLE 2. UNLOCK STATION, DROP COVER FORWARD MOUNTING INSTRUCTIONS: PULL LEVEL PROTRUDES WHEN ALARMED TO EXPOSE MOUNTING SCREWS. 1. COVER & BACKPLATE COME ASSEMBLED. SUPPLIED BY CONTRACTOR _�W� 2. UNLOCK STATION, DROP COVER FORWARD LED INDICATOR FLASHES DURING COMMUNICATION TO EXPOSE MOUNTING SCREWS. TAMPER RESISTANT RESET KEY LOCK 2 1 SUP/2' PL" MOUNTING: SEMI -FLUSH, SURFACE OPERATING TEMPERATURE RANGE: 32 - 120' F OPERATING HUMIDITY RANGE: 0 - 93% RH ADAPTER PLATES 2099-9813 OR 2099-9814 CAN BE USE FOR RETROFIT APPLICATIONS. 5" HIGH X 3 3/4" WIDE X 1' DEEP SCREW TERMINALS FOR 18 TO 14 AWG WIRE ADDRESSED BY MEANS OF AN 8 POSITION DIP SWITCH COMPATIBLE WITH IDNet SLC/MAPNET OPERATION: ACTIVATION: 4099-9004 SINGLE ACTION STATION REQUIRES A FIRM DOWNWARD PULL TO ACTIVATE THE ALARM SWITCH. COMPLETING THIS ACTION BREAKS AN INTERNAL PLASTIC BREAK -ROD THAT IS VISIBLE BELOW THE PULL LEVER (USE OF PLASTIC ROD IS OPTIONAL). THE PULL LEVEL LATCHES INTO THE ALARM POSITION AND REMAINS EXTENDED OUT OF THE HOUSING TO PROVIDE A VISIBLE INDICATION. RESETFING 4099-9004 SINGLE ACTION STATION REQUIRES A KEY TO RESET THE ACTIVATION LEVER AND DEACTIVATE THE ALARM SWITCH. (IF OPTIONAL PLASTIC BREAK ROD WAS USED IT MUST BE REPLACED) CONSTRUCTION: STATION HOUSING AND PULL LEVER ARE CONSTRUCTED OF CHIP RESISTANT AND DIRT RESISTANT, HIGH IMPACT LEXAN. HOUSING IS RED WITH RAISED WHITE LETTERING AND PULL LEVER IS WHITE WITH RED RAISED LETTERING. * LEXAN IS A REGISTERED TRADEMARK OF THE GENERAL ELECTRIC CO. APPLICATION: PULL STATIONS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND ADA GUIDE LINES. INTRODUCTION: THE 4099-9004 ADDRESSABLE PULL STATION PROVIDES TWO -STATE STATUS INFORMATION (NORMAL AND SHORT) TO THE IDNet SLC COMPATIBLE FIRE ALARM CONTROL PANEL (FACP) VIA THE IDNet SLC CHANNEL. THE IDNet SLC CHANNEL PROVIDES THE COMMUNICATION LINK BETWEEN PULL STATION AND THE FACP AND POWERS THE ENTIRE CIRCUITRY. WIRING: 1. ALL WIRING TO COMPLY WITH LOCAL CODE. 2. CONDUCTORS MUST TEST FREE OF ALL GROUNDS. 3. MAINTAIN CORRECT POLARITY 4. IDNet SLC LINES ARE TO BE 18 AWG TWISTED SHIELDED PAIR 5. MAXIMUM LINE RUN FROM PANEL TO FARTHEST DEVICE NOT TO EXCEED 2500 FEET. 6. MAXIMUM TOTAL WIRE (INCLUDING ALL T-TAPS) FROM PANEL NOT TO EXCEED 10,000 FEET. 7. MAXIMUM QUANTITY OF DEVICES PER CIRCUIT: 250 8. TERMINALS I AND 2 FOR FIELD WIRING. TERMINALS 3 AND 4 ARE FACTORY WIRING. 9. WIRE NUT, SPLICE, OR SOLDER THE SHIELD WIRES. 10. IF SHIELD IS PRESENT, IT SHOULD BE CONNECTED TO THE OUTGOING IDNet SLC SHIELD TO PROVIDE A CONTINUOUS SHIELD OVER THE LENGTH OF THE IDNet SLC CHANNEL. SHIELD SHOULD BE INSULATED FROM THE ELECTRICAL BOX. 11. SEE INSTALLATION INSTRUCTIONS 574-332 2975-9178 OR 2975-9022 BOXES FROM SIMPLEX OR WIREMOLD BOX NO. 5747 SUPPLIED BY CONTRACTOR SURFACE MOUNTING 4 11/16" SQUARE x 2 1 2099-9819 BLACK) OR-\ SUPPLIED By CONTRACTOI 2099-9820 BEIGE) FLUSH ADAPS AVAILABLE FROM SIMPLEX MOUNTING INSTRUCTIONS: 1. COVER & BACKPLATE COME ASSEMBLED . 2. UNLOCK STATION, DROP COVER FORWARD TO EXPOSE MOUNTING SCREWS. FLUSH MOUNTING 00 001, 0 0 0, ADDRESS DIP SWITCHES UNDER RE -SEALABLE LABEL SEE INSTALLATION INSTRUCTIONS (574-332 FOR SETTINGS DEEP BOX SEMI -FLUSH MOUNTING "OTE: BOX MUST BE RECESSED INTO WALL 1 TO 1 1/8". CUTOUT MUST BE A MINIMUM 6" HIGH BY 5" WIDE IDNet SLC F1 M23 141 2 SHIELD SHIELD SHIELD +4 TO ADDITIONAL IDNet SLC DEVICES OR RETURN FROM FIRE ALARM CONTROL PANEL OR TO FIRE ALARM CONTROL PANEL FOR STYLE 6 OTHER IDNet SLC DEVICES ON CIRCUIT APPLICATION. TrueAlertTmNON-ADDRESSABLE MULTI -CANDELA VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION WHEN SURFACE MOUNTING USE 4" SQUARE x 1-1/2" DEEP BOX FEATURES: (WALL MOUNT) RED SKIRT NO. 4905-9937 OR - UL LISTED TO STANDARD 1971 4905-9931 ADAPTER PLATE--\ 2975-9145 BOX WHITE SKIRT NO. 4905-994, - ADA COMPATIBLE SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: - SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE FOR CLASS B OR CLASS A OPERATION - SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL NAC INPUTS SPECIFICATIONS: - HOUSING DIMENSIONS: 5-1/8" H X 5" W X 2-3/4" D (130mm X 127mm X 70mm) -TEMPERATURE RANGE: 32'F TO 1227 (0 TO 50'C) • HUMIDITY RANGE: 10% TO 93% NON -CONDENSING AT 10O`F (38*C) • TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER TERMINAL FOR IN/OUT WIRING. WIRING: 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL. S 2 MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS DO NOT LOOP . . WIRES UNDER TERMINALS. 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER -LIMITED. 4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. STROBE: • RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 ULC LISTED: 20 VDC TO 30 VDC PER ULC S526-M878 • FLASH RATE: 1 Hz • SYNCHRONIZED MODE NAC LOADING MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRC­ *CURRENT DRAWS REFLECT STROBE FLASHING MODEL NUMBER HOUSING � COLOR I LE17ERING COLOR STROBE RATING RMS CURRENT @ 16 VDC 18 VDC 24 VDC 4906-9101 1 RED I WHITE 15cd 60 mA 53 mA 40 mA 30cd 94 mA 84 mA 63 mA 75cd 186 mA 165 mA 124 mA 110cd 252 mA 224 mA 168 mA 4906-9103 1 WHITE TRIED 15cd 60 mA 53 mA 1 40 mA 30cd 94 mA 84 mA 1 63 mA 75cd 1 186 mA 1 165 mA 1 124 mT 110ccl 1 252 mA 1 224 mA 1 1 RR mA IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE ELECTRICAL BOTTOM OF LENS BOX OUTLINE IS EITHER EVEN WITH OR SLIGHTLY ABOVE __ BOTTOM OF A COMPATIBLE BOXES NFPA 72 REQUIRES THAT THE ENTIRE LENS BE NOT 80" LESS THAN 80" AND NOT MIN. GREATER THAN 96" ABOVE THE FINISHED FLOOR. CONDUIT CUTOUTS ARE PROVIDED ON ALL FOUR SIDES. FROM A COMPATIBLE SIMPLEX SMARTSYNC NAC OR FROM SMARTSYNC CONTROL MODULE (SCM) 4905-9938 OR SIMPLEX 4905-9914 OR 9922 SYNC CUBE WIRE FOR 6 BE JNTING ALTERNATE BACK BOXES 1. 2 GANG 1-1/2" DEEP BOX 2. SINGLE GANG 1-1/2" DEEP BOX SEMI -FLUSH MOUNTING TO ADDITIONAL NOTIFICATION APPLIANCE DEVICE OR RETURN TO FACP FOR STYLE Z APPLICATION IF LAST DEVICE ON CIRCUIT IN A +4 STYLE Y APPLICATION PLACE A RMINALS 3 & 4 ARE NOT USED 10K 1/2W END -OF LINE RESISTOR T, CD L L L 0 DL MIN limliffill INE, I iml 105_�__ '11m INTENSITY SELECTION PLUG, ACCESSIBLE ONLY FROM REAR OF HOUSING; FACTORY SETTING IS 15cd STROBE INTENSITi VIEWING SLOT TM TrueAlert NON -ADDRESSABLE MULTI -CANDELA SPEAKER/VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION (CEILING MOUNT) FEATURES: *CURRENT DRAWS REFLECT STROBE FLASHING - UL LISTED TO STANDARD 1971 & 1480 - ADA COMPATIBLE SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: MODEL J-HR-00 NUMBER �UES ING COLOR I LETTERING S TROBE RATING RMS CURRENT @ 16 VRMS 1 18 VIRMS 124 VRMS 4906-91541 WHITE I RED 15cd 75mA I 67mA 1 50mA 30cd 125mA I 111 mA I 83mA 75cd 233mA�� 155mA 110cd 316mA 1 281 mA 1 211 mA 4" (102mm) SQUARE, 1 1/2" (38mm) DEEP BOX WITH 1 1/2" EXTENSION (BY OTHERS) xne 0 SYNCHRONIZATION MODULES FOR CLASS B (STYLE Y) OR CLASS A (STYLE Z) OPERATION 0 SPECIFICATIONS: * SPEAKER HOUSING DIMENSIONS: 7 1/2" DIA X 1/2"D (191 MM X 13MM) - STROBE LENS PROTRUSION DIMENSION: 2 5/8" (67MM) ABOVE SPEAKER HOUSING - DEPTH INTO BOX 2 3/4" (70MM) WIRING INPUT TERMINALS AND SPEAKER TAP SELECTION ARE ACCESSIBLE FROM REAR OF SPEAKER HOUSING -TEMPERATURE RANGE: 327 TO 122'F (0 TO 50*C) • HUMIDITY RANGE: 10% TO 93% NON -CONDENSING AT 100-F (38-C) • TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER TERMINAL FOR IN/OUT WIRING. WIRING: 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL. 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP STROBE INTENSITY WIRES UNDER TERMINALS. VIEWING SLOT 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER -LIMITED. 4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. SPEAKER dBA AT 10' (RATED WATTS) 1/4 1/2 1 2 REVERBERATE CHAMBER ILL 464 TEST 76 dBA 79 dBA 82 dBA 85 dBA ANECHOIC CHAMBER 87 c8A 90 dBA 93 dBA 96 dBA STROBE: 0 0 Ln INTENSITY SELECTION PLUG, ACCESSIBLE ONLY FROM RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC REAR OF LENS HOUSING; ULC LISTED: 20 VDC TO 30 VDC PER ULC S526-M878 FACTORY SETTING IS 15cd - FLASH RATE: 1 Hz - SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. TO ADDITIONAL NOTIFICATION APPLIANCE DEVICES (STROBE) OR RE TURN TO FACP FROM FACP 16-33VDC NON -CODED NOTIFICATION + OR SYNC MODULE FOR STYLE Z APPLICATION APPLIANCE CIRCUIT OR PRECEDING DEVICE IF LAST DEVICE ON CIRCUIT IN A STYLE Y APPLICATION PLACE A 10K 1/2W END -Of - LINE RESISTOR FROM FIRE ALARM CONTROL PANEL OR TO ADDITIONAL 25 OR 70VRMS SPEAKERS OR OTHER 25 OR 70VRMS SPEAKER CIRCUIT RETURN TO FACP FOR STYLE Z APPLICATION +-4 IF LAST DEVICE ON CIRCUIT IN A STYLE Y SPEAKER TAP APPLICATION PLACE A 10K 1/2W END -Of - JUMPERS LINE RESISTOR Jum er Pollf-lon Voltage Watt Top J1 to TaD 70.7 VRMS. 1 4 J11 J11 to to To B To C 1 2 1 J1 to Tab D 2 J11 to T P D a � 25 VRMS I 1 4 J1 to T itol 1 1/2 J1 to 1 T1 16 _T6 D G 2 PRODUCT INFORMATION 4098-9792 STANDARD SENSOR BASE FEATURES: - ILL LISTED, FM APPROVED - TRUEALARM ANALOG SENSING PROVIDES DIGITAL TRANSMISSION OF ANALOG 4" X 1 11�2R DEEP OCTAGONAL SENSOR VALUES VIA MAPNETIl, OR IDNet SLC TWO WIRE COMMUNICATIONS * FIRE ALARM CONTROL PANEL PROVIDES: 4" SQUARE X 1 1/2" DEEP, WHICH REQUIRES -INDIVIDUAL SENSITIVITY SELECTION FOR EACH SENSOR A 4098-9832 ADAPTER PLATE (6-3/8" X 1/4") -PEAK VALUE LOGGING ALLOWING ACCURATE ANALYSIS FOR SENSITIVITY SELECTION BOX SUPPLIED BY CONTRACTOR -AUTOMATIC ENVIRONMENTAL COMPENSATION -DISPLAY OF SENSITIVITY IN PERCENT PER FOOT -MULTISTAGE ALARM OPERATION -ABILITY TO DISPLAY AND PRINT DETAILED SENSOR INFORMATION IN PLAIN ENGLISH LANGUAGE MAPNETII/IDNet ADDRESS DIP SWITCHES - PHOTOELECTRIC SMOKE SENSOR 4098-9714: SEE BASE INSTALLATION INSTRUCTIONS SEVEN LEVELS OF SENSITIVITY FROM 0.2% TO 3.7% 574-709 FOR SETTINGS 9 IONIZATION SMOKE SENSOR 4098-9717: FOUR LEVELS OF SENSITIVITY FROM 0.5% TO 1.7%. HEAT SENSOR 4098-9733: -RATE-OF-RISE TEMPERATURE DETECTION IS SELECTABLE AT THE CONTROL PANEL FOR EITHER 157 4098-9714 PHOTOELECTRIC SMOKE SENSOR OR 20*F PER MINUTE 4098-9717 IONIZATION SMOKE SENSOR -FIXED TEMPERATURE SENSING IS INDEPENDENT OF RATE -OF -RISE AND PROGRAMMABLE TO OPERATE AT 135*F OR 1557 1(13 -TRUEALARM HEAT SENSORS CAN BE PROGRAMMED AS A UTILITY DEVICE TO MONITOR FOR TEMPERATURE EXTREMES IN THE RANGE FROM 32* F TO 120' F. 4098-9733 HEAT SENSOR - UL STANDARD SPACING: -60 FT SPACING FOR 135* F -40 FT SPACING FOR 155* F - INTEGRAL RED LED FOR POWER -ON (PULSING), OR ALARM OR TROUBLE (STEADY ON) - BASE MOUNTED ADDRESS SELECTION: -ACCESSIBLE FROM FRONT (DIP SWITCH UNDER SENSOR) -ADDRESS REMAINS WITH ITS PROGRAMMED LOCATION FLUSH MOUNTING FOR USE WITH SIMPLEX 4010, 4100, 4020, AND 4120 SERIES CONTROL PANELS. (BOX TO BE FLUSH OR RECESSED 11/4� MAXIMUM) MAXIMUM QUANTITY OF DEVICES: -127 FOR 4020, 4100, 4120 -250 FOR 4010, 4100 MOUNTING: CEILING OR WALL COLOR : FROST WHITE BASE DIMENSIONS: 15/16" X 4-7/8" SPECIFICATIONS: - ILL LISTED TEMPERATURE RANGE: 327 TO 1007 - OPERATING TEMPERATURE RANGE: 327 TO 120*F - HUMIDITY RANGE: 10% TO 95% RH * PHOTOELECTRIC SENSOR AIR VELOCITY RANGE: 0-2000 FT/MIN - IONIZATION SENSOR AIR VELOCITY RANGE: 0-300 FT/MIN - WIRING CONNECTIONS: SCREW TERMINALS FOR N/OLIT WIRING, #18 TO #14 AWG - COMMUNICATIONS MAPNETII/IDNet SLC: I ADDRESS PER BASE umandum VOLTAGE (MAPNETII IDNet SLC): 24-40VDC CURRI 41CAL comm +7--, DESCRIPTION: TRUEALARM SENSOR BASES CONTAIN INTEGRAL ADDRESSABLE ELECTRONICS THAT CONSTANTLY MONITOR THE STATUS OF THE DETACHABLE PHOTOELECTRIC, IONIZATION, OR HEAT SENSORS. EACH SENSOR'S OUTPUT IS DIGITIZED AND TRANSMITTED TO THE SYSTEM FIRE ALARM CONTROL PANEL EVERY FOUR SECONDS. SINCE TRUEALARM SENSORS USE THE SAME BASE, DIFFERENT SENSOR TYPES CAN BE EASILY INTERCHANGED TO MEET SPECIFIC LOCATION REQUIREMENTS. THIS FEATURE ALLOWS INTENTIONAL SENSOR SUBSTITUTION DURING BUILDING CONSTRUCTION. WHEN CONDITIONS ARE TEMPORARILY DUSTY, INSTEAD OF COVERING THE SMOKE SENSORS. HEAT SENSORS MAY BE INSTALLED WITHOUT REPROGRAMMING THE CONTROL PANEL, L ALTHOUGH THE CONTROL PANEL WILL INDICATE AN INCORRECT SENSOR TYPE, THE HEAT SENSOR WILL OPERATE AS A DEFAULT SENSITIVITY PROVIDING HEAT DETECTION FOR BUILDING PROTECTION AT THAT LOCATION. WIRING: _j + 1. ALL WIRING TO COMPLY WITH LOCAL CODE. _j 2. CONDUCTORS MUST TEST FREE OF ALL GROUNDS. FROM PREVIOUS OPTIONAL SHIELD TO ADDITIONAL MAPNETII/IDNet DEVICES 3. MAINTAIN CORRECT POLARITY MAPNETII/IDNet DEVICE5 OR RETURN TO FIRE ALARM CONTROL 4. MAPNETII/IDNet SLC WIRING TO BE #18 AWG TWISTED SHIELDED PAIR OR FIRE ALARM PANEL FOR A STYLE 6 APPLICATION 5 IF SHIELD IS PRESENT CONNECT TO THE OUTGOING IDN t SLC SHIELD CONTROL PANEL . , e TO PROVIDE A CONTINUOUS SHIELD OVER THE LENGTH OF THE IDNet SLC CHANNEL. METHOD OF SPLICE DETERMINED BY AHJ. 6. REFER TO INSTALLATION INSTRUCTIONS (574-707) 7. REFER TO APPLICATION MANUAL (574-709) TrueAlertTmNON -ADDRE S SABLE MULTI -CANDELA SPEAKER/VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION (WALL MOUNT) FEATURES: - ILL LISTED TO STANDARD 1971 & 1480 STANDARD ELECTRICAL BOX MOUNTING - ADA COMPATIBLE STANDARD ELECTRICAL BOX MOUNTING 4" SQUARE BOX, 1-1/2" DEEP, - OPTIONS FOR WALL MOUNT SPEAKER VISUALS: 4" SQUARE BOX, 1-1/2" DEEP, WITH A 4" SQUARE BOX EXTENSION, - SKIRTS FOR SURFACE MOUNT ELECTRICAL BOXES WITH A 4" SQUARE BOX EXTENSION, 1-1/2" DEEP, SUPPLIED BY OTHERS .(7) RED 4905-9946, WHITE 4905-9947 1-1/2" DEEP, SUPPLIED BY OTHERS <7) ' SKIRT - 4905-9998 WIRE GUARD TRANSPARENT HOUSING AND LENS ASS BLY C) . SURFACE MOUNT ADAPTER 30�1 6" (81mm) DEEP. 0 SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: C DUIT CUTOUTS ARE PROVIDED ON ALL FOUR SIDES. t SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE FOR CLASS B OR CLASS A OPERATION 1/1') REMOVABLE COVER (TOOL REQUIRED) SPECIFICATIONS: - HOUSING DIMENSIONS: 7-1/4" H X 5" W X 2-5/8" D (184mm X 127mm X 67mm) -TEMPERATURE RANGE: 3ZF TO 1227 (0 TO 50'C) - HUMIDITY RANGE: 10% TO 93% NON -CONDENSING AT 1007 (38'C) - TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER TERMINAL FOR IN/OUT WIRING. WIRING NOTES: 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL. 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP WIRES UNDER TERMINALS. 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER -LIMITED, 4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. STROBE: - RATED VOLTAGE RANGE: ILL LISTED: 16 VDC TO 33 VDC PER UL 1971 ULC LISTED: 20 VDC TO 30 VDC PER ULC S526-M878 - FLASH RATE: 1 Hz - SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. *CURRENT DRAWS REFLECT STROBE FLASHING HOUSING LETTERING MODEL NUMBER COLOR COLOR STROBE RATING RMS CURRENT @ 16 VDC 18 VDC 1 24 VDC 4906-9151 RED WHITE 15cd 60 mA 53 mA 40 mA 30cd 94 mA 84 mA 63 mA 75cd 186 mA 165 mA 124 mA 110cd 252 mA 224 mA 1 168 mA 4906-9153 WHITE RED 15cd 60 mA 53 mA 40 mA 30cd 94 mA 1 84 mA 63 mA - 75cd 186 mA 1 165 mA 124 mA mA 224 mA 168 mA SPEAKER: FREQUENCY RESPONSE: FIRE ALARM: 400 TO 400OHz GENERAL SIGNALING: 125 TO 12kHz SPEAKER OUTPUT RATINGS @ 10 FF. (3m) 1/4W 1/2W 1W 2W REVERBERATE CHAMBER UL 464 TEST 76 dBA 79 dBA 82 dBA 85 dBA ANECHOIC CHAMBER 87 dBA 90 dBA 93 dBA 96 dBA STROBE INTENSITY VIEWING SLOT SEMI -FLUSH MOUNT TrueAlert SPEAKER JUMPER SE71NGS JUMPER POSITION VOLTAGE SETTING J1 TO TAP A J1 TO TAP B 70.7VRMS 1/4 1/2 J1 10 Alf T 1 77777-T 2 J1 TO TAP J1 TO TAP E J1 TO TAP F 25VRMS 4 12 J1 TO TAP G WIRING INPUT TERMINALS AND SPEAKER TAP SELECTION ARE ACCESSIBLE FROM REAR SPEAKER ASSEMBLY STROBE ASSEMBLY INTENSITY SELECTION PLUG, ACCESSIBLE ONLY FROM REAR OF HOUSING; FACTORY SETTING IS 15cd IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE 2975-9145 4" SQUARE BOX OUTLINE BOX OUTLINE �T � 1- 1 /2" 78-1/2" NFPA 72 REQUIRES THAT MIN. THE ENTIRE LENS BE NOT 82" GREATER THAN 96" ABOVE MIN. THE FINISHED FLOOR. SPKR - SPKR + STROBE INTENSITY VIEWING SLOT SPKR - SPKR + SPKR + FROM AUDIO NAC CHANNE SPKR + SPKR + SPKR - (4100/4003) (SEE WIRING NbTES) - I f-07 ----------- SPKR - SPKR - FROM STANDARD NAC OR NAC + COMPATIBLE SIMPLEX SMARTSYNC =0 STROBE + 0 STROBE + NAC - NAC OR FROM SMARTSYNC CONTROJI STROBE - OBE - MODULE (SEE WIRING NOTES) NAC - INTENSITY SELECTION PLUG, ACCESSIBLE ONLY FROM REAR OF HOUSING; FACTORY SETTING IS 15cd SURFACE MOUNT OPTION SPKR - STROBE + =npr END -OF -LINE RESISTOR (VALUE DEFENDANT ON FACP) c'j =0 0000 w;z 04 C? T mm 0000 04 cjj uj 0 t= 0 =) C3 U) 0 �0 cr_ U.1 C-4 uj 00 0 -q- L9 co 04 z; 'q m c14 cn c) LU cn - �� 00 IL 0 z U- 6i L4 m u') S2 0 W i_z 0 2-7 0 > j 0 uj >. 0 = uj ry 0 06 co cy') 0 C/) < > 0 < LLJ __j M _1 Ell ZD - cf) 0 U) 0 X Lu < w M 0 (D >- uj U, 0 U.-) _j C) UJI U- 0 0 w Lu _j co cn DRAWN BY: B. KNICKLE CHECKED BY: F. REINHART ISSUE DATE: 7/19/16 CURTIS ENGINEERING SERVICE, LLC - CA#31561 JAMES M. CURTIS, P.E. - PE#37912 JOB 292415807 29775 BAYHEAD ROAD PROJECT#: 1292:993523001 DADE CITY, FLORIDA 33523 SIMPLEXGRINNELL @ 2016 DEL EGA TED ENGINEER OF RECORD SYSTEM: )igitally signed NN!�,o :)y J a m e s C u rt i s No. 3 Date: cw 2016.07.22 OR%O ONAt. '09:34:17 -04'00 1111111% FIRE ALARM SYSTEM SHEET: TYPICALS WIRING FA-703 m 3 0 ti Q w 3 0 aD -o 0 w E a� N Cn C7 CD C"M CV LO co d a t T L Q N CO Q N O C6 �L _Q co T CD ca d E co CV m m N CD _O d 2 H ¢ a w LL m 0 w U) g T N T CD T 0 N N N ti W H Z_ d H Cn t m N_ C) W L CV X O M