7050 Gall Blvd (122)
301 East Pine Street #350 O 407-893-5800 Orlando, Florida 32801 F 407-468-2128 rsandh.com Revision 6 Narrative ADDENDUM NO. 4 Surgical Suite-OR(s) Build -Out AdventHealth Zephyrhills 01-14-21 REVISED DRAWINGS: S101 — LOW ROOF/ 3RD FLR FRAMING PLAN - Revised OR 9 framing plan - Added note 6 - Added detail 2/S101 S201 — SECTIONS & DETAILS - Revised Sections 7/S201 and 8/S201 - Removed unused detail 4/S201 M102 - DEMOLITION PLAN — HVAC - Added general note based on AHCA comment M103 - NEW CONSTRUCTION PLAN — HVAC - Added general note based on AHCA comment P101 - DEMOLITION PLAN - MEDICAL GAS O/Z- b-9 - Revised demo plan to leave the existing medical gas valve boxes existing to remain - Added floor plan view to show existing medical gas service valve location - Revised notes P106 - NEW CONSTRUCTION PLAN - MEDICAL GAS RS&H, Inc FL Cert. Nos. AAC001886•JB26000956•LCCO00210 a rsandh.com Revised new floor plan to leave the existing medical gas valve boxes existing to remain - Revised medical gas pipe routing Revised and added notes END OF REVISION 6 NARRATIVE Page 2 of 2 Q Cl) N IT N N O N ti A expressed written consent of this corporation is prohibited. All rights reserved. d -- T—-rTrrr-7-_ —r—_ --_—� - _ - _ 1 1, I. �,�,. .{'mil'. �� n;, i� .;_I:� l� i ��.. _k: 1. ,1.. � i.,, ��i lip � � 1 I ii � i I I� i I � ��� __�_�—* _—FI -r _— F� expressed written consent of this corporation is pronatea. Ni ngnis reservea. 2 3 4 5 IC A 2 a co v N N 0 N (M A n 0 A z DEMOLITION PLAN - MEDICAL GAS SCALE: 1/4" = V-0" PLUMBING KEYNOTES 1 EXISTING MEDICAL GAS SERVICE SHUT OFF VALVES ARE LOCATED AT THE END OF CORRIDOR ABOVE CEILING. SEE FLOOR PLAN ON THIS SHEET FOR ONT NU TIO . 2 EXISTING C 2 MANIF LID TO R MAIN. 3 EXISTING CO2 MAIN SHUT OFF IN VALVE BOX. TLCJENGINEERING ... IS 0 LU T I ON S, ©Copyright 2019 255 S. Orange Avenue Suite 1600 COA 15 Orlando, FL 32801 www.tic-engineers.com --- - P 407.841,9050 TLC No.:119469 THINK. LISTEN. CREATE. KEY PLAN - LEVEL 2 0 0 SCALE: N.T.S. TRUE PROJECT NORTH NORTH PROJECT TITLE: AdventHealth - ZEPHYRHILLS OPERATING ROOMS BUILT OUT PROJECT ADDRESS: 7050 GALL BLVD, ZEPHYRHILLS, FL, 33541 Aaron Lee Johnson, P.E. 11, Florida License #71576 N E E dCy � G'E N S . N� ��� o o �• . 0�.. • No 71576 N 7{ f • • .O WM W 9 ' STATE OF fNA•� � `% c=n U ( (f�ZZ Uj 0 w a W J UL- 0 O U REVISIONS z w NO. DESCRIPTION DATE 6 ADDENDUM No. 4 01.14.22 5 ADDENDUM No. 3 11.10.21 2 ADDENDUM No.1 07.12.21 DATE ISSUED: 12/11/2019 REVIEWED BY: XX DRAWN BY: XX DESIGNED BY: XX PROJECT NUMBER: 504-0253-000 0 2019 RS&H, INC. SHEET TITLE: DEMOLITION PLAN - MEDICAL GAS SHEET ID: BLDG. ID Pi 01 PROJECT STATUS: CONSTRUCTION DOCUMENTS Copyright 0 2019. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the expressed written consent of this corporation is prohibited. All rights reserved. 3" SCALE 0 3" 6" 1' 1 1/2" SCALE 0 6" 1' 2' 3/8" SCALE 3' 0 18" 3' 6' 1/4" SCALE 4' 0 2' 4' 8' 1/8" SCALE 8' 0 4' 8' 16' 1 1 2 1 3 1 4 1 5 0 C 3 A 5 IL 0 0 v M CD N O N M SCALE: 1/4" =1'-0" MEDICAL GAS OUTLETS MARK DESCRIPTION MOUNTING QUANTITY OF OUTLETS NOTES MGEB MEDICAL GAS CEILING 1-NIT, 2- CO2 O EQUIPMENT BOOM 3-VAC W/SLIDES MEDICAL GAS CEILING 2-OX,1- N20,1-MA 0 MGAB ANESTHESIA BOOM 1-WAGD & 2 VAC W/SLIDES NCP-1 NITROGEN CONTROL WALL 1-NITROGEN 2O PANEL zzi� A N NURSE STATION SCALE: 1/4" = 1'-0" KEY PLAN - LEVEL 2 (�) 0 SCALE: N.T.S. TRUE PROJECT NORTH NORTH DESIGNED BY: XX PROJECT NUMBER: 504-0253-000 C 2019 RS&H, INC. SHEET TITLE: NEW CONSTRUCTION PLAN - MEDICAL GAS SHEET ID: BLDG. ID P106 PROJECT STATUS: CONSTRUCTION DOCUMENTS Copyright C 2019. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the expressed written consent of this corporation is prohibited. All rights reserved. 3" SCALE 0 3" 6" 1' 1 1/2" SCALE 0 6" 1' 2' 3/8" SCALE 3' 0 18" 3' 6' 1/4" SCALE 4' 0 2' 4' 8' 1/8" SCALE 8' 0 4' 8' 16, 2 9 4 IC C B1 2 3 3 r I A N DEMOLITION PLAN - HVAC SCALE: 1/4" = 1'-0" GENERAL DEMOLITION NOTES 1. THE DEMOLITION PLAN IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA EXISTING EQUIPMENT, STRUCTURE, DUCTWORK, ETC. LOCATED ON DRAWING WERE DERIVED FROM EXISTING DRAWINGS AND LIMITED FIELD OBSERVATIONS. THIS DRAWING MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA. CONTRACTOR SHALL VERIFY SERVICES AND LOCATIONS PRIOR TO ANY DEMOLITION WORK. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT AND ENGINEER PRIOR TO BEGINNING DEMOLITION. BEGINNING OF DEMOLITION SHALL SIGNIFY CONTRACTOR'S ACCEPTANCE OF EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT. 2. CONTRACTOR SHALL PERFORM A PRE -BID SURVEY TO FIELD -VERIFY AND COORDINATE ALL DIMENSIONS PRIOR TO PROCUREMENT OR FABRICATION. FIELD CONDITIONS SHALL GOVERN. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, AND ELECTRICAL CONDUIT. COST OF REROUTING DUCTWORK OR PIPING DUE TO CONFLICTS WITH EXISTING CONDITIONS SHALL BE PAID BY CONTRACTOR. 3. ALL MECHANICAL SYSTEMS SERVING OTHER SPACES OR FLOORS THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE ANY DISRUPTION TO THESE OTHER SPACES. 4. TEMPORARY MECHANICAL SERVICES SHALL BE PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDING TO REMAIN ACTIVE. COORDINATE SERVICE INTERRUPTIONS WITH OWNER AT LEAST TWO WEEKS IN ADVANCE. 5. ALL EQUIPMENT REMOVED UNDER THIS PROJECT SHALL BE TURNED OVER TO THE OWNER AT THE OWNER'S DISCRETION UNLESS OTHERWISE NOTED. 6. CONTRACTOR SHALL REMOVE OR RELOCATE EXISTING CONTROLS WHERE NECESSARY. REMOVED CONTROLS SHALL BE RETURNED TO OWNER. 7. PROPERLY REMOVE AND DISPOSE OF ALL EXISTING TO BE REMOVED HVAC DUCTWORK, PIPING AND AIR DISTRIBUTION DEVICES. CONSULT WITH OWNER AND OBTAIN OWNER'S APPROVAL PRIOR TO DISPOSAL OF REMOVED MATERIAL. 8. PATCH HOLES LEFT IN WALLS AND FLOORS AFTER REMOVAL OF EXISTING DUCTWORK, CONDUIT, ETC. TO MATCH NEW OR EXISTING CONSTRUCTION AND FIRE RATING. THIS INCLUDES ANY EXISTING OPENINGS IN RATED WALLS OR FLOORS. 9. PROVIDE PRECONSTRUCTION TEST & BALANCE FOR SUPPLY, RETURN AND EXHAUST OF EXISTING MECHANICAL EQUIPMENT SERVING PROJECT AREA. INCLUDE FLOW AND STATIC PRESSURE IN MAIN DUCTS, FAN STATIC PRESSURE, MOTOR HP AND FLA, PRESSURE DROP ACROSS AHU COILS AND FILTERS, CHILLED WATER FLOW AND PRESSURE AT AHU. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING THE AIR HANDLER AND DUCTWORK SERVING THE AREA PRIOR TO FINAL TEST AND BALANCE. CLEANING OF THE AIR HANDLER AND DUCTWORK SHALL CONSIST OF REPLACING THE FILTERS. 11. ALL EXISTING AIR DISTRIBUTION DEVICES LOCATED WITHIN PROJECT AREA SHALL BE FITTED WITH TEMPORARY CONSTRUCTION FILTERS THROUGHOUT PROJECT DURATION TO HELP PREVENT ACCUMULATION OF DUST IN DEVICES AND DUCTWORK. 12. CAP ALL DEMOLISHED BRANCH DUCT AT DUCT MAIN. CAP AND SEAL OPENINGS DURING ENTIRE RENOVATION OF THE HVAC DUCTWORK. 13. ALL EXISTING AND/OR NEW WALL, CEILING AND FLOOR PENETRATIONS TO THE SPACE SHALL BE CAULKED AND SEALED AIR AND VAPOR TIGHT AFTER DEMOLITION AND PRIOR TO NEW CONSTRUCTION BY AN APPROVED CONTRACTOR. 0 DEMO KEY NOTES PROVIDE A TEMPORARY HEPA FILTERED NEGATIVE AIR FAN FOR CONSTRUCTION AREA. MAINTAIN A MINIMUM 0.03" NEGATIVE PRESSURE IN THIS AREA RELATIVE TO THE ADJACENT SPACES. PROVIDE VISUAL DISPLAY OF AIRFLOW DIRECTION. PROVIDE ADDITIONAL NEGATIVE AIR MACHINES AS REQUIRED TO ACHIEVE MINIMUM NEGATIVE PRESSURE. PROVIDE TEMPORARY DUST BARRIER PARTITIONS. ALL EXISTING RETURN REGISTERS AND OPENINGS LOCATED WITHIN THE RENOVATION AREA SHALL BE SHUT AND TAPED CLOSED, ISOLATING THE RENOVATION AREA FROM THE AIR HANDLER SYSTEM. ALL EXISTING EXHAUST REGISTERS LOCATED WITHIN THE RENOVATION AREA SHALL BE PROVIDED WITH TEMPORARY CONSTRUCTION FILTERS. ROUTE TEMPORARY 120 FLEXIBLE DUCT FROM DISCHARGE OF HEPA UNIT TO OUTSIDE OF DEMOLITION BOUNDARY. FAN CRITERIA: MODEL - HEPA-AIRE MODEL PAS2400HC CFM - 700-2100 CFM HPN/P-1.51120/1 O2 PROVIDE AN INCLINED MANOMETER, DIFFERENTIAL PRESSURE TYPE, WITH WHITE FACE GAUGE AND BLACK LETTERS WITH MAXIMUM PRESSURE RANGE OF 0.1" W.G. THIS SHALL BE USED BY THE CONTRACTOR TO RECORD, ON A DAILY BASIS, THE NEGATIVE PRESSURE IN THE RENOVATION AREA 20 RELATIVE TO THE ADJACENT SPACES. O CONTRACTOR TO PROVIDE TEMPORARY CONSTRUCTION BARRIER. ® DEMO DUCTWORK TO POINT INDICATED. CAP AND SEAL AIRTIGHT WHERE NECESSARY. O5 EXISTING DIFFUSER TO BE RELOCATED. © DEMO PIPING TO POINT INDICATED. CAP AND VALVE, SEE NEW FLOOR PLAN FOR NEW PIPING LOCATION. 0 EXISTING DUCTWORK UP TO (E)EF-30 ON ROOF ABOVE SHALL REMAIN. ® PROVIDE TEMPORARY WALL PENETRATION FOR NEGATIVE AIR MACHINE DISCHARGE DUCT. REPATCH WALL AFTER CONSTRUCTION. O9 EXISTING STEAM CONDENSATE PIPE TO BE REROUTED TO AVOID NEW DUCTWORK. CUT EXISTING STEAM CONDENSATE AND PREPARE PIPE FOR NEW CONNECTIONS. 301 E. Pine Street, Suite 350 Orlando, Florida 32801 407-893-5800 Fax 407-264-6624 www.rsandh.com FL Cert. Nos. AAC001886 * IB26000956 5620 * LCC000210 * GB238 a TLC I S0LUT10ING ©Copyright 2019 255 S. Orange Avenue Suite 1600 COA 15 Orlando, FL 32801 www.tic-engineers.com P 407.841.9050 TLC No.:119469 THINK, I . CREATE. PROJECT TITLE: AdventHealth - ZEPHYRHILLS OPERATING ROOMS BUILT OUT PROJECT ADDRESS: 7050 GALL BLVD, ZEPHYRHILLS, FL, 33541 - --- Aaron Lee Johnson, P.E. Florida License #71576 LE E Jo No 71576 zr= '. STATE OF �.• ................___.__.. . . . •f��'`S�O N A KEY PLAN - LEVEL 2 SCALE: N.T.S. TRUE PROJECT NORTH NORTH REVISIONS NO. DESCRIPTION DATE 6 ADDENDUM No. 4 01.14.22 5 ADDENDUM No. 3 11.10.21 2 ADDENDUM No.1 07.12.21 DATE ISSUED: 12/11/2019 REVIEWED BY: ALJ DRAWN BY: LLP DESIGNED BY: LLP PROJECT NUMBER: 504-0253-000 © 2019 RS&H, INC. SHEET TITLE: DEMOLITION PLAN - HVAC SHEET ID: BLDG. ID M102 PROJECT STATUS: CONSTRUCTION DOCUMENTS Copyright © 2019. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the expressed written consent of this corporation is prohibited. All rights reserved. 3" SCALE 0 3" 6" 1' - -T_ 1 1/2" SCALE 0 6" 1' 2' 3/8" SCALE 3' 0 18" 3' 6' AIt"11,1, ..1l; 1, id IF iLi,. � ! I i ,�� )�) 1/4" SCALE 4' 0 2' 4' 8' 1/8" SCALE 8' 0 4' 8' 16' 1 1 2 1 3 1 4 1 5 N C 0 A B N N [N,--�4 NEW CONSTRUCTION PLAN - HVAC SCALE: 1/4" = V-0" ROOM VENTILATION CALCULATIONS ROOM PRESS. RELATIONSHIP DESIGN AIR FLOW REQUIRED REQUIRED DESIGN SUPPLY RETURN EXH AC/H OA AC/H CFM OA CFM AC/H OA AC/H OR #8 POSITIVE 2500 2050 0 20 4 1950 390 25 4 OR #9 POSITIVE 2500 2050 0 20 4 1967 393 25 4 SUB-STERLE NR 200 0 500 6 2 109 37 22 2 SCRUB NR 100 0 0 6 2 47 16 12 2 EGUPIENT NR 125 125 0 2 0 55 0 4 0 STORAGE NR 125 125 0 2 0 37 0 6 0 CORRDOR NR 500 400 0 4 2 490 245 4 2 Q KEY NOTES r 1O BALANCE EXISTING EXHAUST DUCT TO 510 CFM PAST THIS POINT: SUBSTERILE - 274 = 385 CFM; SCRUB - 273 = 75 CFM; SUBSTERILE - 274 = 50 CFM. O PROVIDE NEW DUCT FIRE DAMPER AT FIRE RATED WALL. O3 DUCTWORK TO/FROM EXISTING AHU-27 LOCATED IN PENTHOUSE. ® DUCTWORK TO/FROM EXISTING AHU-29 LOCATED IN PENTHOUSE. OLOW WALL RETURN. MOUNT BOTTOM OF GRILLE AT 0'-9" A.F.F. 2 © STAINLESS STEEL STEAM LINE FROM HUMIDIFIER TO DUCT SHALL NOT EXCEED IT IN LENGTH PER MANUFACTURER RECOMMENDATION. 7O PROVIDE STAINLESS STEEL DUCTWORK FOR AT LEAST 6' AFTER STEAM CONNECTION. ® COORDINATE EXISTING AND NEW DUCT ROUTING WITH OR'S EQUIPMENT SUPPORT FRAMES. Q PROVIDE ROOM PRESSURE CONTROL PANEL. COORDINATE WITH OCCUPIED/UNOCCUPIED MONITOR AT NURSE STATION, SEE DETAIL #1 ON SHEET M402 FOR MORE INFORMATION. 10 COORDINATE AN ACCESSIBLE LOCATION FOR THE CONTROL VOLUME DAMPER PANEL, SEE DETAIL #1 ON SHEET M401 FOR MORE INFORMATION. ►ee 301 E. Pine Street, Suite 350 Orlando, Florida 32801 407-893-5800 Fax 407-264-6624 www.rsandh.com FL Cert. Nos. AAC001886 * IB26000956 5620 * LCC000210 * GB238 TLCENGINEERING iLUT10NS ©Copyright 2019 255 S. Orange Avenue Suite 1600 COA 15 Orlando, FL 32801 www.tic-engineers.com P 407.841.9050 TLC No.:119469 THINK. LISTEN. PROJECT TITLE: AdventHealth - ZEPHYRHILLS OPERATING ROOMS BUILT OUT PROJECT ADDRESS: 7050 GALL BLVD, ZEPHYRHILLS, FL, 33541 Aaron Lee Johnson, P.E. Florida License #71576 '�%ttjjjl �E E ' jo **,Oi ON,� �. •.� o\G�ENs No 71576 STATE OF i� If rl REVISIONS NO. DESCRIPTION DATE 6 ADDENDUM No. 4 01.14.22 5 ADDENDUM No. 3 11.10.21 2 ADDENDUM No.1 07.12.21 DATE ISSUED: 12/11/2019 REVIEWED BY: ALJ DRAWN BY: LLP DESIGNED BY: LLP PROJECT NUMBER: 504-0253-000 © 2019 RS&H, INC. SHEET TITLE: NEW CONSTRUCTION PLAN - HVAC SHEET ID: BLDG. ID M103 Copyright © 2019. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the expressed written consent of this corporation is prohibited. All rights reserved. 3" SCALE 0 3" 6" 1' 1 12" SCALE 0 6" 1' 2' 3/8" SCALE 3' 0 18" 3' 6' 1 /4" SCALE 4' 0 2' 4' 8' KEY PLAN - LEVEL 2 SCALE: N.T.S. TRUE PROJECT NORTH NORTH 1/8" SCALE 8' 0 4' 8' 16, PROJECT STATUS: CONSTRUCTION DOCUMENTS