7050 Gall Blvd (129)
N 0 N 0 ORIDA HOSPITA P HYRHI S Cat ab NI qui-pment 7050 Gall Boulevard Ze h rhills IFI 33541 l� Y Client Code/ ]File Number: 23/100046-1 10-1 - AHCA Stage III I . I I PROJECT TEAM DIRECTORY SYMBOLS AND MATERIALS GENERAL NOTES INDEX OF DRAWINGS A0.0 Cover Sheet OWNERIndustry standards (I.e. ASTM, ANSI, etc.) SHALL HAVE THE SAME FORCE AND EFFECT STRUCTURAL on performance of work as if copies were directly Inserted Into the Contract Documents or bound and Florida Hospital Zephyrhills published therewith. Comply with standards in effect as of the date of the Contract Documents, unless otherwise note or required by authorities having jurisdiction. 51.1 Equipment Support Demolition and Framing Plan 7050 Gall Boulevard ARCHITECTURAL Zephyrhills, Florida 33541 O WINDOW TYPE EARTH CODES - All work shall conform to the following codes and ordinances: A1.0 Life Safety Second Floor Plan Phone: (813) 788-041 1 $ ELEVATION BENCHMARK GRANULAR FILL - 2007 Florida Building Code,wlth 2009 amendments �� - 2007 Florida Plumbing Code,with 2009 amendments P, - Florida Fuel Gas Code, 2009 ALI ICRA Floor Plan A2.0 Floor plans �0 REVISION AND NUMBER 2007 with amendments - 2007 Florida Mechanical Code, with 2009 amendments ��. Ti" ► C44 - 2010 Florida Fire Prevention Code - Effective December 31,2011 A2.1 Schedules and Details ARCARCHITECTLk- METAL p Local Codes and Ordinances where applicable and flood damage prevention ordinances f � A2.2 Specifications C.J.D CONTROL JOINT2005 FINISH WOOD 2009 NFPA 101 - Life Safety Code cdda_ NFPA 99 - Health Care Facilities ggU"�"` II 11 2006 Guidelines for Design and Construction of Health Care Facilities v� Architects, Burt H111 /Pollock Krieg Inc.c PLUMBING 8250 College Parkway Suite 203 DOOR AND FRAME WITH DOOR NUMBER STUCCO OR GYPSUM BOARD DD BUILDING CODE INFORMATION : ���� OCCUPANCY GROUP :GROUP 1-2 P1.2 Plumbin Plans g Fort Myers Florida 33919 , ° � • °' CONCRETE OR GRAVEL TYPE OF CONSTRUCTION : TYPE I-B Phone: (239) 482-4761 EXISTING DOOR TYPE 1(3,30 FULLY SPRINKLERED (NFPA) 239 482-0265 Fax: ( ) METAL STUD WALL ® CONCRETE MASONRY UNIT (CMU) SQUARE FOOTAGE OF REMODELING: 702sgft MECHANICAL 77777777777 MASONRY WALL ® PLYWOOD 1. Contractor to oversee cleaning and Insure that the premises are maintained free of rubbish during construction. Final cleanup Is the responsibillty of the Contractor. Contractor to provide Permitting Authority with Debris Affidavit at time of submittal. M0.0 HVAC Legend and Symbols M1.1 HVAC Demolition and New Work MECHANICAL/ELECTRICAL ENGINEERS EVALUATION ROOM NAME AND NUMBER 208 ® ACOUSTIC CEILING TILE 2. At the termination of work, submit to Building Agent/Tenant maintenance manuals presenting full details for care and maintenance of all surfaces and equipment of every nature. Contents shall Include manufacturer's and Installer's names, addresses, and phone numbers, and M4.1 HVAC Details and Schedules B� WALL TYPE Instructions for Installation, start-up, operation, maintenance ports list, and data sheets. Heery Internatlon Inc BAiT OR SEMI -RIGID INSULATION BUILDING SECTION 3. Contractor Is responsible for compliance with all Codes, Ordinances and Regulations applicable at project location. Contractor Is responsible for fling and securing all necessary permits, approvals, etc. for all trades. ALL«rot�t'� _e ELECTRICAL p� sAl1. ctip, 1�ITA i, CODE,ILIM3 • 4700 Millenia Blvd, Suite 550 RIGID INSULATION DETAIL 4. When 'or equal', 'alternate', or other qualifying terms are used, those Items shall be approved by Building Agent/Tenant and/or Architect. L�� ELL Demo & Power Plan �NATIONgI EiE 14DA&ALDING E1.2 Ll htm and Communication Plays OFZEP ��OCODEA C COD ND Lighting HALLS Orlando, Florida 32839 Phone: (407) 992-6316 V� SECTION OR ROUGH WOOD FRAMING OR BLOCKING ELEVATION 5. Existing materials or Items scheduled to remain that are damaged by construction shall be repaired, patched, and reflnlshed to the nearest intersection, restoring surface to It's original condition. O E3.1 Riser Diagram & Schedules ES E4,1 Enlarged Cath Lab, Details & Schedules Fax: (407) 992-6399 ® INTERIOR ELEVATION 6. Contractor shall protect all existing walls, doors, frames, surfaces, fixtures, finishes, etc. from damage during demolition and construction. Existing materials to be removed shall be coordinated with Owner to verify if Owner wishes to salvage some. Relocotlon of salvaged materials, once removed, to be by the Building Agent/Tenants forces E4,2 Details & Schedule E5.1 Details /7- C/7� i F yovV_ F Z �- PANS NORTH ARROW 7. Contractor shall verify and be responsible for all dimensions and job site conditions related to this work. Any discrepancy In dimensions or special modlflcatlons required due to field conditions shall be reported to the Architect for clarification MY 'E� Rfyf(,LS �( � 8. The Architect does not have control or charge of, and shall not be held responsible for construction means, methods, techniques, sequence or for safety precautions and programs in connection with work, for the acts or omissions of the contractor, sub -contractors or any other persons FIRE PROTECTION performing any of the work, or for the failure of any of them to carry out the work In accordance with the Documents. F1,2 Fire Protection Plan 9. All pipes, ducts, conduit, etc., which penetrate the final slob or walls shall be installed so as to maintain the fire resistive and structural Integrity of the building construction. I0. Demolition of existing construction necessary to Install new construction and equipment Is to be performed by the contractor who is to supply and Install the new construction and equipment. Install Ilntels where required with prior written approval. Il. Contractor to repair floor slabs, flil gaps, cracks and voids. Grind smooth any high spots or ridges. Floors to be prepared as required to receive floor finishes so that previous substrate defects cannot be detected. Refer also to Omega Medical Imaging Install drawings titled OMI-CS-20-FP SINGLE PLANE ELECTROPHYSIOLOGY IMAGING SYSTEM 12. GENERAL CONDITIONS OF THE CONTRACT, AIA Document A201, latest edition, shall apply. 13. All gypsum board In partitions around 'wet use areas' ( i.e.: Toilet Room(s), Laundry Room(s), Shower Room(s), etc.) shall be of moisture-reslstant type, and these partitions ore to be sound -rated. VICINITY MAP 14. All studs, furring and miscellaneous metal accessories In walls having moisture -resistant gypsum board are to be of galvanized metal. 15. All flre-roted partitions are to extend to deck above, and have all voids packed between the deck and top of wall with fire sofeing Insulation. Floor track Is to be set In a bed of sealant. Joints in gypsum board partitions are to be taped over the full height of the partition. 16. Fire extinguisher cabinets mounting height to be 2'-6' from floor to bottom of receptacle. Top of extinguisher to be 4'-0' AFF, max. 17. All non-flre-rated partitions are to extend 4' above suspended ceiling grid. All such partitions are to be braced back to the structural deckingor joists with suitable sub-fromin at 48' o.c., max. Provide additional framin , bracing and blocking for all required cobinetr I 9 9 9 9 q Y """ " . � and equipment. 18. Not all listed GENERAL NOTES may apply, nor are they all-inclusive for every work situation. Excellence, throughout the job, does apply. ` ...... 19. Each FIRE WALL, FIRE BARRIER, FIRE PARTITION, SMOKE BARRIER, SMOKE PARTITION, or any other new wall required to have protected openings shall be permanently Identified with signs or stenciling above any In the SMOKE PROTECTED f . 3.. .; •.n vv N. a decorative ceiling and concealed spaces with words,'FIRE AND BARRIER - ALL OPENINGS', or similar language. Such or stenciling shall be In 4-Inch high letters, %2-inch stroke, and not more than l5-feet on center. fi Project 51 i 1 • Project No. 12010.00 AOOO ©2012 BH/PK Architects, Inc. 311312012 2:34:31 PM ...\cd\AO-0 Cover Sheet.dgn N Q ST 00. 0 co o� i tD Project No. 12010.00 sial © 2012 BH/PK Architects, Inc. N v- 0 0 v- N O N BUILDING CODE ANALYSIS I. Codes in effect: 2007 Florida Building Code, with 2009 amendments 2009 NFPA 101- Life Safety Code Florida Administrative Code 59A3 2006 Guidelines for Design and Construction of Health Care Facilities 2. Use and Occupancy Classification: Group 1-2 As per FBC Chapter 3 and NFPA l01 J. Type of Construction: Type I-B.Fully Sprink/ered As per FBC Section 602 and NFPA 101 Table 8.1 Type 1 f3.3.2f 4. Interior Finish Requirements As per FBC Table 803.5 and NFPA /01 Table A 10.2.2 Exits: Type A Exit Access Corridors: Type A Rooms & Enclosed Spaces: Type A TRUE 1 LIFE SAFETY SECOND FLOOR PLAN,( NORTH AI.O J 118 • • /'-0• " ITAO'k" Muls Project No. 12010.00 00000 . A1.00 rl• 1:M ©2012 BH/PK Architects, Inc. 311312012 3:18:58 PM ...\AI-0 Life Safety Plan - 2nd Floor.dgn V- INFECTION CONTROL MEASURES: 1. The Contractor shall obtain from the hospital a copy of the infection control risk assessment iICRAI prepared for this project. The contractor shall review the requirements in this report and preform all work In N accordance with those requirements. The contractor shall strictly adhere to the limits of the construction area, and where phasing applies shall adhere to the phasing plan. Any work outside the construction are shall be coordinated with the faclllty and preformed In accordance with the /RCA report, under the supervision of the hospital's representative or other designated ICRA committee officer. Y, v- O _ 2. To the extent that it is required by the ICRA the contractor shall endeavor to maintain existing levels of Indoor air quality in areas surrounding and adjacent to the construction work zone, and elsewhere In the foclIlly.It should be anticipated that the ICRA report will require measures to this effect Including erection of construction zone barriers and provisions for negative air pressure in the construction zone relative to other areas of the facility. Failure to comply with construction and maintenance of construction barriers will result In the cesatlon of work until the barriers are brought Into compliance. J.Contractor to monitor room to assure room maintain negative pressure. 4. Any requirement for interruption or shut down of utilities made necessary by this construction shall be coordinated with the facility of least one week prior to Interruption. 5. Contractor shall endevor to minimize any disruption of surrounding areas of the hospital 6. All debris will be removed in covered carts. Wheels will be cleaned prior to entering the building from outside or from the construction area Fire retardant wood noiler Close open ducts with 6 mll fireretardant poly Seal with duct tape Close ceiling space with 6 mil fire retor, Poly Seal a?l Joint penetrations with duct Seal around all pipe and duct penetrations in the partition and poly barrier with duct tape r-2- TEMPORARY ICRA WALL Al,l 314 ' • 1'-0' ;ticol ceiling file Te psum wall board re h occupied side with paint D Go J%' Metal studs 1' O.C. foints 1th ram -tuck >r equal I ' ICRA FLOOR PLAN Al / 1116 ' , r'-0' TRUE PLAN NORTH NORTH U U �•1 C�4 N O N 00 U o rn JX O o, ►� C 00 V N w M O �' Z 0No w a C1 O N H � p U y N � M Q o o y 3 H r� C� Cd U Vi V-4 . rl � N c4 Cd O � 1� Cd O Project No. 12010.00 AIJ I©2012 BH/PK Architects, Inc. 311312012 9:02:23 AM ...\A1-1 ICRA Plan - 2nd Floor.dgn N V- CO �o 0 er- N co ca f 311912012 4:23:34 PM ...\cd\A2.0 Floor Plon.dan All interior finishes to be Class I or Class A REFLECTED CEILING PLAN LEGEND ® 2x2 FLUORESCENT FIXTURE ® 2x4 FLUORESCENT FIXTURE RECESSED OR SURFACE MOUNTED DOWN LIGHT ® EXIT LIGHT WITH ARROW • SPRINKLER HEAD o LINEAR SUPPLY DIFFUSER 0 LINEAR RETURN REGISTER ® SUPPLY DIFFUSER ® RETURN REGISTER OR GRILLE GYPSUM CEILING, SOFFIT OR BULKHEAD (provide closure at both sides as required) C.J.D CONTROL JOINT Elev FINISH CEILING ELEVATION (A.F.F.) 8'-0. REFLECTED CEILING PLAN NOTES: 1. Refer to Electrical drawings for fixture types, counts and circulting. 2. Refer to Mechanical drawings for diffuser and register sizes. J. Sldewall registers, diffusers and sprinkler heads are not shown on Architectural reflected ceiling plans. 4. Coordinate locations of electrical, mechanical and fire protectlr:. devices with Architectural reflected ceiling plans. I I I I Remove gqxlsting wall and CORRIDOR 4'-0' do& and frame as requlredlfor new doors MaIntoln'smoke thlghtness and rodl!,otion I >ection CORRIDOR INN0, , , VWII 41, 0 E E E Existing building steel�J above New 2x2 loyIn suspended acousticalcelllng to remain ■ /� —� 7cmNOM002MNaMIRefer to MEP drawings for � ..�—_ Q� _ light I and , S■_E�New 2x2 loyIn suspended Lounge I Existing unlstrut to remain. Unlstrut specialty engineer to verify adequacy to support I new equipment I I i-1 �— Monitor rolls I I Existing 2x2 loyln suspended acoustical ceiling to remain Gypsum board drop 8'-O' A.F.F Sk OR 0 0 ON 'roject No. 12010.00 A2,00 1 ©2012 BHIPK Architects, Inc. LM N 0 v N \ 0 Q 0 a- w rn o ca v- N 9 KE ROOM E/N/SH SCHEDULE DOOR SCHEDULE NO. ROOM NAME FLOOR BASE WALLS CEILING REMARKS DOOR FRAME REMARKS N DETAILS W Q Q Qz OZ�i ca z V C W Q- ti O Z Z = a z SIZE Ii HEAD JAMB T HRSHLD U-jti Uj ? Q = 200 2'-0'&4'-0' x 13/' B WOOD STAIN A HM PAINT 4/A2.0 LEAD LINED !'"O. L2.0 • DOT DENOTES �c QW N 2 SCHEDULE REMARKS AND ABBREVIATIONS FINISH LOCATION jN QI 200 Cath Lab `I • • • 1 • 9'-33/ ' 20 20 minute fire rated door, frame and hardware 8'-0' Oi 201 Control Room • 45 3/ hour label fire rated door, frame and hardware 90 I%2' hour label fire rated door, frame and hardware ALUM Aluminum storefront system HM Hollow metal frame 202 Equipment Room • • • • 8'-0' SCHEDULE REMARKS AND NOTES QExisting Control Room to be painted, replace any damage ceiling panels. Patch all finishes /n corridor to match. (2) 20 go metal studs Sealant bot sides %6' lead llr h.m, frame (grout solid %6' lead lining Jamb & floor anchor clips %6 ' lead lined door LEAD LINED H.M. DOOR HEAD DETAIL 3B = 1'-0" 7 r)rxlr Width 7 TYPE A Hollow metal frame IE 3A O5 Building roof I I I I I I I I o, o x _ a� U Building steel FF ^� -Verify existing loc(t on unlstrut support X-Roy equipment 5/8' gypsum board ceiling on metal framing 0 Wall and window to I maintain radiation protection = U I I I I I I I I I I I I I I I I 1 StGJ IUN A2.1 1/4 ' - 1'-0' Existing lead window to remain �: plywood countertop plywood built-up st plastic /ominate on all surf aces. 2' bockslosh Provide computer tray TYPE B Wood -lead lined Countertop brace,l'-0' radius on 3/4' plywood with plastic laminate finish provide as required and shown on 2 COUNTERTOP ELEVATION ui suppor, maximum ted length spacing 5' o• A2.1 1/4 ' - 1'-0' `xisting lead line window ?' high plastic laminate back end side splash sealed to the volt with clear sealant 3/4' plywood countertop with 3/4' plywood built-up subbase )lastic laminate on all exposed surfaces ;omputer tray location by Owner Installed by contractor Countertop brace, P-O' radius on 3/4' plywood with plastic laminate finish Existing gypsum board wall 3 COUNTER SECTION A2.1 3/4 ' - P-O' I P�P Ir'll �u U 14 U bA L N N 00 U o M ca M n N .� N U 0 c� F y N H R 1--1 O o Gy 3 F-• A Cd rc� Cd V r--a C� � N t� c� E Cd U Zo Con 4-4 Project No. 12010.00 A2,01 .3/IS/ZUIZ 9:Ub:.3/ AM ...\AZ.l 5cnedule and deralis.agn 0I I a 02012 BH/PK Architects, Inc. DIVISION I - GENERAL SECTION 01045 - CUTTING AND PATCHING Scope: I. Cutting and patching Includes cutting Into existing construction for the Installation or performance of other work and patching required to restore the surfaces to their N original condition. a. Unless otherwise specifled the requirements for this section also apply to mechanical and electrical work. b. Do not cut and patch exposed work In a manner that In the Architect/Engineers opinion results in lessening the buildings aesthetic qualities. Replace any work Judged by the Architect/Engineer to be satisfactory. c. Do not cut and patch exposed work 1n a manner that would result In the _ reduction of load carrying capacity or load deflection ratio. When In doubt notify the Architect/Engineer. N SECTION 01300 SUBMITTAL'S, PRODUCTS, AND SUBSTITUTIONS o Scope: I. Format for submittals: As required for specific type and by Individual sections. 2. Types of submittals and number of copies. N o a. Shop drawings, reviewed and annotated by the General Contractor: 6 copies b. Product data - 6 copies c. Samples - 2, plus extra samples as required to indicate range of color, flnlsh, and e texture to be expected. d. Mock-ups - As required In individual sections. e. Inspection and test reports - 4 copies e f. Warranties - 2 copies g.Survey data - 2 copies. h. Closeout submittals - 2 copies a DIVISION 3 - CONCRETE SECTION 03310 - CAST IN PLACE CONCRETE Scope: I. Provide cost-in-ploce concrete for general building construction, Including, without limitation: e o. Mlscelloneous patching as required. Products: I. Formwork: Plywood forms sufflclent for structural and aesthetic requirements a- 2. Reinforcements a. Bars: Deformed steel, ASTM A 615, Grade 60 b. Mesh: Welded wire fabric, ASTM A 185 c. Supports for reinforcement: Use wire type supports complying with CRSI speclflcatlons.Use plastic supports for epoxy coated reinforcements. J. Concrete materials: N a. Cement: Portland cement, ASTM C150, Type 1. b. Aggregate: Normal weight aggregates, ASTM C 33. c. Water: Potable O N d. Fly ash: ASTM C 618 Type C or F. Fly ash not to exceed 20Z of cementltlous 'v materials. 4. Related Materials: a. Vapor barrier under slab on grade: 6 mll polyethylene with edges lapped taped. b. Liquid membrane forming curing compound: liquid type conforming to ASTM G309 type I-0, Class A dissipating. c. Hardener: Non- metallic, Inter lor/exterfor type. 5. Concrete Mixes: a. 3000 psi for footings and slabs on grade 6. Ready made Concrete: Comply with requirements of ASTM C94. a- 7.Concrete Finishes: a. Float finish: Monolithic slob surfaces exposed to view. b. Trowelled Finish.. For all interior slab surfaces. N o c. Broom flnlsh: Concrete steps and exterior paving. d. Scotch flnlsh: Exterior paving base. M' o e. Hardener: Exposed concrete floors and loading areas. v N DIVISION 6 - WOOD AND PLASTICS SECTION 06100 - ROUGH CARPENTRY Scope: I. Provide rough carpentry work a. Nollers, blocking, furring and sleepers Products: 1. Lumber, flnlshed 4 sides.197 maximum moisture content. a. Light framing: Construction grade Douglas fir or southern pine, appearance grade where exposed. b. Structural framing and timbers: No. I grade Douglas fir or southern pine, appearance grade where exposed. N c. Boards: Construction grade o 2. Wood for milers, furring and sleepers: Construction grade, flnlshed 4 sides, 19Z moisture content. Pressure preservative treat items in contact with roof Ing. f lashing, woterproof Ing. masonry, concrete or the ground. N J. Plywood, APA rated for use and exposure. a. Backing: Interior A/C grade. 4. Building paper: Asphalt saturated felt, non -perforated, ASTM D 226, Type 1.30 Ibs 5. Wood treatment: a. Exterior wood AWPA standard UI and Tl. Categories UCI, UC2, UC3A, UC3B, CU4A, CU4B Alkaline Copper Ouaternary based treatment. b. Interior wood AWPA Cl Timber, AWPA C9 Plywood, AWPA C31 Lumber not °p In contact with ground and protected from water, AWPA 5 Waterborne Preservatives, AWPA M4 Disodlum Octoborate based treatment. a 6. Sealants: For settings wood bucks and nailers In exterior openings. 7. Fire Retardant Treated Wood: All wood blocking within the Insulated building envelope shall be fire retardant treated to comply with AWPA C20 (lumber) and AWPA C27 (plywood) for treatment type. a. Provide UL label on each treated. Ready treated lumber. 311312012 9:07:05 AM ...\Cath Lab 'I\cd\A2.2 specs.dgn SECTION 06400 - ARCHITECTURAL WOODWORK Scope: 1. Provide shop fabricated woodwork and casework. Products: I. Ouallty standard for fobrlcotlon and products: Architectural Woodwork Institute Ouallty Standards, Premium grade flush overlay unless otherwise noted. 2. Wood type a. Provide sealed plywood at sinks and wet areas. 3. Plastic laminate: a. Horizontal surfaces: GP-50 (0.050' nominal thickness) b. Vertical surfaces: GP-28 (0.28' nominal thickness) c. Seml-exposed surfaces: Plastic laminate BK-20 4. Solid surface countertop a. As selected by Owner SECTION 07900 - JOINT SEALERS Scope: 1. Provide sealant of Intersection of building components. a. Non-elostomeric caulking compounds for Interior work Products: 2. Latex (non elostomeric) sealants for Interior Joints. a. Manufacturers standard one part, non sag acrylic sealant complying with C 834 SECTION 08110 - STEEL DOORS AND FRAMES Scope: I. Provide hollow metal door frames, sidelight and transom framing. Products: I. Frames: Welded construction with mitered corners: gage over 5' wide. a. Interior frames:16 gage up to 5' wide, 14 gage over 5' wide b. Exterior frames: 14 gage. 2. Finish: Rust -Inhibiting primer. J. Fire rating: UL labelled, fIre-rated assembly where required. DIVISION 9 - FINISHES SECTION 09250 - GYPSUM DRYWALL Scope: I. Gypsum drywall including screw type metal support systems. 2. Drywall finishing: To match existing. J. Moisture resistant gypsum board for installation In wet areas such as toilet rooms, mop rooms, Janitors closets, food service areas, behind fiberglass showers, and under the balance of wall the Installations. Do not Install in showers. 4. Cementltious backer board for use in showers.. Products: 1. Gypsum wallboard: ASTM C 36, of types, edge configuration and thickness indicated: In maximum lengths available to minimize end -to -end butt Joints a. Type: %' Type 'X' b. Edges: Tapered c. Thickness: As indicated, or If not otherwise Indicated, as required to comply with ASTM C840 for application system and supporting spacing Indicated. J. Wall/Partition Support Materials: a. Studs: ASTM C645: 20 gage unless otherwise indicated. Use 16 gage steel studs at shower seat supports, rolling counter service doors or where required by equipment 4. Celling suspension and furring materials: Steel runners and galvanized hanger wire; stainless steel wire. 5. Accessories: Galvanized steel corner beads. casing beads, control Joints 6. Acoustical sealant: US Gypsum Acoustical Sealant SECTION 095I0 - ACOUSTICAL CEILINGS Scope: I. Provide acoustical ceilings and metal suspension system. 2. Fire Performance Characteristics: Provide materials that are identical to those tested for the following fire performance characteristics, per ASTM test method Indicated below, by UL or other testing and Inspecting organizations acceptable to authorities having jurisdiction. Identify acoustical ceiling components with appropriate markings of applicable testing and inspecting organizations. a. Flame spread 25 or less b. Smoke developed 450 or less 3. Install products per manufacturers recommendations. Products: I. Acoustical panels: As selected by Owner 2. Exposed grid suspension system: To match existing. J. Extra materials a. Provide additional panels and grid In an amount equal to 2.0 percent of each type of specifled for maintenance stock. SECTION 09650 - RESILIENT FLOORING Scope: I. Provide resilient flooring and base 2. Install per manufacturers recommendations 3.Fire Test Performance: Provide, Class I resilient flooring which compiles with the following fire test performance criteria as determined by an Independent testing laboratory acceptable to authorities having Jurisdiction. a. Critical Radiant Flux (CRF): Not less than the following rating per ASTM E 648. 0.45 watts per sq. cm. b. Flame Spread: Not more than 25 per ASTM E 84. c. Smoke Developed: Not more than 450 per ASTM E 84 d. Smoke Density: Not more than 450 per ASTM E662 Products: I. Flooring; As selected by Owner 2. Accessories a. Wall base: 4' hlgh,%8' thick, matte finish vinyl with preformed corners. As selected by Owner. J. Adhesives (Cements): Waterproof, stabilized type as recommended by flooring manufacturer to suit material and substrate conditions. 4. Concrete slob primer: Non -staining type compatible with adhesive as recommended by flooring manufacturer. 5. Leveling compound: Latex type compatible with adhesive as recommended by flooring manufacturer. 6. Extra materials: a. Provide additional resilient flooring for maintenance stock as directed by Owner. SECTION 09900 PAINTING Scope: !.Provide painting and surface preparation for all Interior and exterior surfaces, as required 2. Prepare surface and apply per manufacturers recommendation. Products: I. Premium products for all systems 2. Interior Point Schedule: New Surfaces: a. Zinc-cooted Metal I. Semi -Gloss Alkyd Enamel: 2 flnlsh coots over primer b. Primed Metal I. Seml-Gloss Alkyd Enamel: Two coots over existing primer c. Smooth Finish Dry Wall: I. Satin or Seml Gloss (Owners Option) Latex Finishes: Two coats over primer d. Existing Zinc Coated or Primed Metal: I. Seml Gloss Alkyd Enamel: (2) coats over prepared surface. DIVISION 10 - SPECIALTIES SECTION 10190 - Cubicle Curtains Scope: I. Provide extruded aluminum track for cubicle curtains. 2. Provide cubicle curtains Products: I. Provide channel track of continuous lengths and curved bends as required by plan. 2. Fittings to be aluminum to match finish of track. J. Carriers to have nylon wheels and nickel plated brass axles. 4. Curtain: Class A product complying with NFPA 701 Top 20' of curtain to be open mesh.Color and style to be selected by Owner DIVISION 10 - SPECIAL CONSTRUCTION SECTION 13090 - Radiation Protection Scope: 1. Provide radiation shielding and radiation protection work. for radiology and radio therapy functions and where indicated on drawings including existing construction that is being relocated. 2. Refer to report from Certified Health Physicist for required lead thickness. Products: I. Units lined and fabricated with lead; a. Doors b. Door frames c. Gypsum drywall d. Control window e. Sheet lead Products: I. Lead lined doors and frames where Indicated on plans. 2. Gypsum drywall; a. ASTM 1396 %' Type 'X' with sheet lead factory bonded to one side. J. Existing Control window a. Size and extent as shown on drawings X-ray proof with hollow metal from and leaded gloss to provide equivalent protection of adjacent partition. 4. Sheet lead, a. Sheet lead complying with FS00-L-201 grade C. Ouallty Control: I. Comply with NCRP standards for Installation. 2. Test in place radiation shielding In accordance with NBS procedures. Testing to be done by Certified Health Physicist, prior to room occupancy. ca.fj. )z Project No. 12010.00 A2,02 02012 BH/PK Architects, Inc. _ _ I III I I I 1 11 J, L I I I _T_ _I I I I I I I I I I ITA Oak" US NR IN RO 5" N CO Nl N 00 PLUMBING PLAN SCALE: Y8" =1' - 0" e VAC OX- PLUMBING LEGEND DESCRIPTION ABBREVIATIONS MEDICAL AIR MA MEDICAL VACUUM MVAC OXYGEN OX CAP UNION RISER DOWN (ELBOW) RISER UP (ELBOW RISE OR DROP TOP TAKE -OFF EXISTING TO BE REMOVED LIMIT OF REMOVAL NEW TO EXISTING GENERAL NOTES 1. THE FOLLOWING NOTES ARE GENERAL IN NATURE AND PERTAIN TO THE ENTIRE PROJECT. WHERE THERE ARE EXCEPTIONS, ADDITIONS, OR REVISIONS TO THESE NOTES SUCH EXCEPTIONS, ADDITIONS OR REVISIONS ARE SO NOTED ON THE PARTICULAR DRAWING THEY OCCUR. 2. PIPING IS SHOWN IN SCHEMATIC FORM. ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. 3. REFER TO ARCHITECTURAL PLANS FOR LOCATION OF ALL EQUIPMENT. 4. VERIFY ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS CERTIFIED DRAWINGS. FIELD VERIFY AND COORDINATE ALL DIMENSIONS PRIOR TO FABRICATION. 5. FIELD VERIFY ALL EXISTING CONDITIONS DURING DEMOLITION AND REROUTE PIPING CONFIGURATIONS AS NECESSARY. 6. UNLESS NOTED OR OBVIOUS OTHERWISE, PIPE RUNS SHOWN OCCUR IN THE CEILING SPACE OF THE LEVEL INDICATED ON PLANS. U.L. LISTED MEDICAL GAS OUTLETS OUTLET BEACON MEDICAL MEDAES STYLE QUICK CONNECT LOCATION OXYGEN MEDAES-TYPE QUICK -CONNECT 6-121030-00 CATH LAB VACUUM MEDAES-TYPE QUICK -CONNECT 6-121033-00 CATH LAB VACUUM SLIDE 6-120978-00 CATH LAB MEDICAL AIR MEDAES-TYPE QUICK -CONNECT 6-121032-00 CATH LAB design Heery International Inc. 4700 Millenia Boulevard, Suite 550, Orlando, Florida 32839 407.992.6300 EB 0005176 Seal: EivgF. s * No 3 A — o V. MAR 1 ;;12 GARY D. STARRETT - PE #33443 Project No. 12010.00 P102 © 2012 BH/PK Architects, Inc. I $DATE$ $TIME$ $FILER$ HEATING & AIR CONDITIONING SYMBOLS ON y ., N p r O 00 N 0 00 In O N - r SYMBOL SINGLE LINE DOUBLE LINE UP (DN) 20x12 20x12 DESCRIPTION EXHAUST OR RELIEF AIR DUCT - UP (SOLID) DOWN (DASHED) RETURN OR OUTDOOR AIR DUCT - UP (SOLID) DOWN (DASHED) SUPPLY OR DISCHARGE AIR DUCT - UP (SOLID) DOWN (DASHED) CHANGE OF ELEVATION IN DIRECTION OF AIR FLOW - UP OR DN (DOWN) DUCT SIZE - FIRST FIGURE IS SIDE SHOWN DUCT END - CAPPED ELBOW WITH TURNING VANES RADIUS ELBOW - WITH TURNING VANES FOR DUCT WITH R=30" OR MORE ABBREVIATIONS SYMBOL XX /XXX DESCRIPTION SMOKE DETECTOR - DUCT MOUNTED VOLUME DAMPER DUCT TRANSITION FLEXIBLE CONNECTION SA DIFFUSER IN BOTTOM OF DUCT EA OR RA REGISTER OR GRILLE AS INDICATED IN BOTTOM OF DUCT TYPE DESIGNATION DIFFUSER, REGISTER, GRILLE AIRFLOW, CFM SYMBOL DESCRIPTION SINGLE LINE DOUBLE LINE STANDARD BRANCH - S IPPLY, RETURN OR EXHAUST WITH VOLUME DAMPER AS INDICATED NAME DUCT SYSTEM DESIGNATION E (NAME) EXISTING DUCT SYSTEM DESIGNATION FLEXIBLE METAL DUCT THERMOSTAT/TEMPERATURE SENSOR a— DUCT MOUNTED THERMOSTAT/SENSOR O HUMIDITY SENSOR ROUND DUCT - UP \' (2) ROUND DUCT - DOWN LIMIT OF DEMOLITION POINT OF CONNECTION - NEW TO EXISTING GENERAL NOTES - MECHANICAL AHU AIR HANDLING UNIT N.C. NORMALLY CLOSED 1. THESE GENERAL NOTES APPLY TO ALL M SERIES DRAWINGS. 10. PAINT FLAT BLACK THE INSIDE OF ALL DUCTWORK VISIBLE THROUGH DIFFUSERS, GRILLES, NO NUMBER AND REGISTERS. BCS BUILDING CONTROL SYSTEM N.O. NORMALLY OPENED 2. NOT ALL SYMBOLS, ABBREVIATIONS AND NOTES MAY BE USED FOR THIS PROJECT. 11. ALL DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS. BTUH BRITISH THERMAL UNITS PER HOUR OA OUTSIDE AIR OAI OUTSIDE AIR INTAKE 3. PROVIDE OFFSETS AND TRANSITIONS IN DUCTWORK AND PIPING AS REQUIRED TO AVOID 12. CONCENTRATE LOADS AT JOIST/BEAM LOCATIONS. PROVIDE ANGLE BRACES CFM CUBIC FEET OF AIR PER MINUTE OC ON CENTER INTERFERENCE AT NO ADDITIONAL COST TO THE OWNER. WHERE CONCENTRATED LOADS OCCUR AT OTHER LOCATIONS. RA RETURN AIR 4. VERIFY ALL EQUIPMENT CONNECTIONS WITH MANUFACTURER'S CERTIFIED DRAWINGS. D6 DEGREE DRY BULB TEMPERATURE ROOF TOP UNIT PROVIDE TRANSITIONS TO FINAL TO EQUIPMENT. MAKE FINAL CONNECTION TO 13. COORDINATE ALL DOOR UNDER -CUTS INDICATED AND REQUIRED FOR PROPER AIR DIA DIAMETER EQUIPMENT, UNLESS OTHERWISE INDICATED. FIELD VERIFY ALL DIMENSIONS BEFORE MOVEMENT. DN DOWN S SMOKE DETECTOR FABRICATION OF WORK. DX DIRECT EXPANSION � SA SUPPLY AIR 14. USE RADIUS DUCTWORK ELBOWS WHERE POSSIBLE. PROVIDE TURNING VANES FOR SF SUPPLY FAN 5. EXACT LOCATION OF DIFFUSERS, GRILLES AND REGISTERS SHALL BE COORDINATED WITH SQUARE ELBOWS IN SUPPLY AIR DUCTWORK AND AS INDICATED. EA EXHAUST AIR SPEC SPECIFICATION THE REFLECTED CEILING PLANS BEFORE INSTALLATION. PROVIDE SYMMETRY WITH THE EAT ENTERING AIR TEMPERATURE SQ FT SQUARE FEET ROOM LIGHTING SYSTEMS. 15. FIRE -SAFE PIPE AND DUCTWORK PENETRATIONS OF ALL FIRE RATED AND SMOKE EDB ENTERING DRY BULB TEMPERATURE SP STATIC PRESSURE 6. VERIFY DIFFUSER, GRILLE AND REGISTER MOUNTING FRAME TYPES WITH THE CEILING RESISTIVE CONSTRUCTION. COORDINATE WITH LIFE -SAFETY PLANS. EF EXHAUST FAN TYPES. MATCH FRAME TYPE WITH CEILING CONFIGURATION. EWB ENTERING WET BULB TEMPERATURE TD TEMPERATURE DIFFERENCE 16. MOUNT ROOM THERMOSTATS AND OTHER CONTROL DEVICES AT 48-INCHES AFF, EX EXISTING TEMP TEMPERATURE 7. DUCTWORK SHALL BE INSTALLED AS CLOSE AS POSSIBLE TO UNDERSIDE OF BEAMS AND UNLESS OTHERWISE INDICATED. FC FLEXIBLE CONNECTION T STAT TSP THERMOSTAT TOTAL STATIC PRESSURE JOISTS. 17. INSTALL ALL EQUIPMENT LEVEL AND PLUMB. PROVIDE BLOCKING AND FD FF FIRE DAMPER FINAL FILTER TYP TYPICAL 8. PROVIDE ACCESS DOORS OR PANELS IN CEILING AND WALLS TO PERMIT SERVICE TO HARDWARE AS REQUIRED. FT FOOT OR FEET UC DOOR UNDERCUT DAMPERS, VALVES, AND CONCEALED EQUIPMENT. HP HORSEPOWER V VENT 18. WORK SHALL BE COORDINATED WITH ALL OTHER TRADES. ROUTING OF DUCTWORK AND HR HOUR Vp VOLUME DAMPER, MANUAL 9. DUCT FITTINGS ARE INDICATED SYMBOLICALLY. REFER TO DETAILS FOR CONFIGURATION OF FITTINGS, TAPS AND CONNECTIONS. DUCT CONSTRUCTION SHALL COMPLY WITH SMACNA PIPING ARE INDICATED TO SHOW GENERAL INTENT. CLEARANCES BETWEEN CEILING AND STRUCTURE ARE MINIMAL IN SEVERAL LOCATIONS. COORDINATE WITH OTHER TRADES VIB. ISO. VIBRATION ISOLATOR CONSTRUCTION STANDARDS. PRIOR TO FABRICATION OF WORK. IN INCH, INCHES LAT LEAVING AIR TEMPERATURE W WIDTH, WIDE LDB LEAVING DRY BULB TEMPERATURE WB WET BULB TEMPERATURE LRA LOCKED ROTOR AMPS W/ WITH LWB LEAVING WET BULB TEMPERATURE W/0 WITHOUT LWT LEAVING WATER TEMPERATURE WC WATER COLUMN WG WATER GAUGE MIN MINIMUM design Heery International Inc. 4700 Millenia Boulevard, Suite 550, Orlando, Florida 32839 407.992.6300 EB 0005176 Seal: •! a i s s• ♦ �i a GARY D. STARRETT - PE #33443 Project No. 12010.00 M060 © 2012 BH/PK Architects, Inc. I $DArL'$ $TIME$ $FILEA$ N N LEN \ r') O SM C\- N Eel o � 03 0 , - I ijbl j i Flpl�'1 rl y it ,.I s r i r,'- : 7 O O �)711 --- - - _ _ I FD I I ' lij xo" I.? ail I N HVAC DEMOLITION PLAN SCALE: %" = 1'- 0" 700 O 300 � --------- --707------- ♦� OI 250(2) I 1 300 O SCOPE OF WORK 100 20500 I v 100 I - U P U (�) P t 0 4 0 ! i n t *'-"4 r- HVAC PLAN - NEW WORK SCALE: %" = 1' - C" T UTILIZE EXISTING ROOFTOP ABANDONED EXHAUST FAN CURB FOR NEGATIVE PRESSURE FAN RELIEF. O AHU-20 OUTSIDE AIR �o AHU-20 TOTAL SUPPLY AIR i i t_I - - IL— - I IL O FE T FD GENERAL DEMOLITION NOTES: 1. PRIOR TO DEMOLITION, MEASURE AND RECORD AIR & WATER QUANTITIES IN UTILITIES REQUIRED TO MAINTAIN OPERATION WITH -IN AND BEYOND 1=ACH DEMOLITION PHASE UNTIL AFFECTED AREAS ARE DEMOLISHED. MAINTAIN THESE QUANTITIES THROUGHOUT EACH DEMOLITION PHASE. 2. MAINTAIN EXISTING AIR HANDLING UNIT (AHU-20) IN OPERATION UNTIL. ITS RESPECTIVE DEMOLITION PHASE IS COMPLETE. BLANK OFF AND SEAL RETURN AIR INTAKES SERVING EACH DEMOLISHED AREA IN ORDER T3 PREVENT GENERATED CONSTRUCTION DEBRIS FROM BEING RECIRCULATED TO OCCUPIED SPACES DURING DEMOLITION --CONSTRUCTION PHASE. BLANK OFF AND SEAL ANY SA, RA AND/OR EA DUCTS BEING DEMOLISHED AND REMAINING WITHIN THE CONSTRUCTION AREA. 3. MAINTAIN NEGATIVE RELATIVE AIR PRESSURE IN DEMOLITION PHASE AREA. MINIMUM HEPA-FILTERED EXHAUST AIR QUANTITY SHALL BE 0.5 TO 0.75 CFM/SQ.FT. UTILIZE MULTIPLE NEGATIVE AIR UNITS, AS NECESSARY, TO MAINTAIN NEGATIVE PRESSURE. PROVIDE REQUIRED MAKE-UP AIR FROM A SEPARATE SOURCE. FANS IDENTIFIED TO BE DEMOLISHED, IN DEMOLITION AREA, AND/OR=XISTING ROOF EXHAUST FANS AND THEIR ROOF OPENINGS MAY BE UTILIZED FOR AIR DISCHARGE UNTIL DEMOLITION PHASE IS COMPLETE. DO NOT UTILIZE EXISTING EXHAUST RISERS THAT SERVE OTHER SPACES OR OTHER LEVELS IN BUILDING. 4. VERIFY NEGATIVE RELATIVE AIR PRESSURE IN THE CONSTRUCTION SPACE BY PROVIDING A MAGNAHELIC GAUGE AND MAINTAINING A WRITTEN LOG, TAKEN AT REGULAR INTERVALS, POSTED FOR REVIEW AT SITE OF CONSTRUCTION. 5. DEMOLISH ALL DUCTWORK, PIPING AND ANCILLARY DEVICES WITHIN AREA OF PHASING PLAN UNLESS OTHERWISE NOTED. ALL BRANCH DUCTS BEING OPENINGS PATCHED, SEALED AND INSULATED TO MATCH EXISTING DUCTWORK. DEMOLISHED FROM MAIN TRUNK DUCTS SHALL HAVE BRANCH CONNECTION 6. DEMOLISH ALL ABANDONED DUCTWORK, DAMPERS, PIPING AND ANCILLARY WALLS TO MATCH EXISTING OR NEW CONSTRUCTION, AS PROJECT DICTATES. DEVICES IN DEMOLITION AREA UNLESS OTHERWISE NOTED. PATCH AFFECTED 7. PRIOR TO DEMOLITION, MEASURE AND RECORD AIRFLOW AT POINTS LISTED O THRU �o SUBMIT REPORT TO ARCHITECT FOR EVALUATION PRIOR TO NEW CONSTRUCTION. KEYED NOTES: OPROVIDE SIX (6) TYPE KA 24x24 PERFORATED SUPPLY AIR GRILLES MOUNTED IN CEILING. BALANCE TO 250 CFM EACH. SEE SCHEDULE FOR DETAILS. 02 BALANCE TO NEW VALUE SHOWN ON PLAN. 03 VERIFY AHU-20 IS BALANCED TO A MINIMUM OF 20% OA. 04 EXISTING, AVERAGING TEMPERATURE SENSORS TO CONTROL SPACE TEMPERATURE(S). _ __ _____ L ----ij ;x ,_ ROOM AIR CHANGE CALCULATION CATH LAB # 1 - REQ ACH = 15 (TOTAL AIR) / 3 (OUTSIDE AIR) ROOM AREA = 500 SO FT CEILING HEIGHT = 9'-3" VOLUME = 500 SO FT x 9.25 FT CLG = 4625 CU FT (CALCULATION IS BASED ON ENTIRE ROOM AT THE HIGHEST CEILING LEVEL) AIR CHANGE _ (1500 CFM x 60) / 4625 CU FT= 19.4 ACH CORRIDOR- REQ ACH = 2 (TOTAL AIR) / NONE (OUTSIDE AIR (AREA OUTSIDE OF CATH LAB) ROOM AREA = 520 SO FT CEILING HEIGHT = 8'-0" VOLUME = 520 SO FT x 8 FT = 4160 CU FT AIR CHANGE _ (600 CFM x 60) / 4160 CU FT= 8.7 ACH design Heery International Inc. 4700 Millenia Boulevard, Suite 550, Orlando, Florida 32839 407.992.6300 EB 0005176 Seal: ti N 3443 0 . F 1 ' & .dam, OW •,�.� °!1l dl i GARY D. STARRETT - PE #33443 Project No. 12010.00 m I I 010I1 IM/M Architects, Inc. FDA, L$ $TIME$ $FILEA$ N 0 N W 00 v N 0 r') O "q- N Nl 0 N 9 0 DIFFUSER, REGISTER AND GRILLE SCHEDULE NOTES; 1. UNITS IZE IS BASED ON AIRFLOW (CFM) AS INDICATED IN THE SCHEDULE BELOW FOR EACH TYPE DESIGNATION. 2. THE LISTING OF A PARTICULAR SIZE IN THE SCHEDULE DOES NOT MEAN THAT IT IS ACTUALLY USED ON THIS PROJECT. 3. PROVIDE ONLY THOSE UNITS INDICATED BY TYPE AND CFM ON THE PLANS. 4. BRANCH DUCT SIZES TO THE DIFFUSERS, GRILLES AND REGISTERS SHALL CONFORM TO THIS SCHEDULE UNLESS NOTED OTHERWISE ON THE PLANS. 5. AT THE CONTRACTORS' OPTION, BRANCH DUCTS MAY BE ROUND OR RECTANGULAR. 6. FOR ROUND NECK DIFFUSERS THE BRANCH DUCT SIZE SHALL BE EITHER THE NECK SIZE INDICATED OR OR THE EQUIVALENT RECTANGULAR BRANCH SIZE INDICATED. 7. FOR SQUARE AND RECTANGULAR DIFFUSERS, GRILLES AND REGISTERS, THE BRANCH DUCT SHALL BE SIZED AS INDICATED, WITH A TRANSITION TO THE ACTUAL NECK SIZE AT THE UNIT, HOWEVER, IF SPACE IS AVAILABLE, THE FULL NECK SIZE MAY BE USED FOR THE ENTIRE BRANCH RUN. 8. ROUND BRANCH DUCTS MAY BE USED FOR SQUARE OR RECTANGULAR DIFFUSERS, GRILLES AND REGISTERS PROVIDED A SUITABLE TAPERED TRANSITION IS USED AND THE EQUIVALENT ROUND SIZE FOR THE LISTED BRANCH DUCT SIZE IS USED. 9. DUCT SIZES INDICATED ARE THE AIR SIDE OPENING DIMENSIONS. INCREASE SHEET METAL DIMENSIONS AS REQUIRED FOR LINING OR OTHER FACTORS. SERIES:AA MODULAR LOUVERED FACE CEILING DIFFUSER WITH 24"x24" FACE BASED ON TITUS TMS NECK RECTANGULAR MINIMUM MAXIMUM SIZE BRANCH DUCT REMARKS AIRFLOW (CFM) AIRFLOW (CFM) (IN DIA.) (INxIN) 0 100 6 8x4 105 210 8 10x6 215 370 10 12x8 375 600 12 148 605 900 14 16x10 905 1100 15 18x10 SERIES:FA FIXED BLADE GRILLE, 314" SPACING FOR RETURN, EXHAUST OR TRANSFER BASED ON TITUS 350 RL NECK RECTANGULAR MINIMUM MAXIMUM SIZE BRUNCH DUCT REMARKS AIRFLOW (CFM) AIRFLOW (CFM) (in x in) (IN x IN) 0 120 6x6 6x6 125 260 8x8 8x8 265 470 10x10 10x10 475 530 12x12 12x10 FRONT BLADE PARALLEL 535 730 1414 1410 TO SHORT DIMENSION 735 810 16x16 16x10 815 960 18x18 18x10 965 1100 20x20 20x10 1115 1375 2424 2400 1380 1570 30x24 30x10 1575 1690 36x24 30x10 1695 1830 42x24 30x10 1835 2100 48x24 3410 SERIES:KA OPERATING ROOM. VERTICAL LAMINAR FLOW DIFFUSER BASED ON TITUS TLF RECTANGULAR MINIMUM MAXIMUM WIDTH LENGTH BRANCH DUCT REMARKS AIRFLOW (CFM) AIRFLOW (CFM) (IN) (IN.) (INxIN) 0 140 24 24 8x6 145 250 24 24 8x8 255 310 24 j 48 1 10x8 Ina ■:111 1 THE EXISTING AIR HANDLING UNIT (AHU-20) SERVES THIS ROOM AND ADJACENT AREAS. THE UNIT IS FITTED WITH A MERV 8 PREFILTER ON THE UPSTREAM SIDE OF THE COOLING COIL AND A MERV 17 FINAL FILTER (WITH A MERV 8 PREFILTER INSTALLED) DOWNSTREAM OF THE SYSTEM FAN. OUTSIDE AIR IS SUPPLIED THROUGH A ROOFTOP INTAKE ABOVE THE MECHANICAL ROOM. UNIT WILL BE BALANCED TO A MINIMUM 20 PERCENT OUTSIDE AIR RATIO TO CCMPLY WITH AIR CHANGE REQUIREMENTS. SUPPLY DUCT INSULATED FLEXIBLE _ METAL DUCT DIAMETER 'D' 0 AS INDICATED ON VOLUME "- o DAMPER BRANCH DUCT _ DRAWINGS U w - BEARING QUADRANT LOCKING LEVER \ 45 EXIT TRANSITION Q' I TO ROUND I PROVIDE CORNER PIECES TO CLOSE OPENINGS ----- � CEILING � I??ii�lTTT EA, RA FLOW ► CEILING DIFFUSER SA FLOW - TRUNK DUCT EXHAUST/ RETURN/ SUPPLYAIR DUCT BRANCH DETAIL NO SCALE \ �I/ SQUARE THROAT RADIUS ELBOW ELBOW WITH VANES (CENTERLINE R = 32 = STD RADIUS) NOTE: DUCTWORK HAS BEEN SHOWN USING SQUARE ELBOWS. RADIUS OR RADIUS WITH VANES MAY BE USED AT CONTRACTOR'S OPTION. NOTE: PROVIDE REQUIRED ELBOWS AND TRANSITIONS TO CONNECT TO BRANCHES. MINIMUM DUCT WIDTH SHALL NOT BE LESS THAN 4". 01 RADIUS ELBOW WITH VANES VOLUME DAMPERS TYPICAL ELBOWS AND SPLITTER DETAIL NO SCALE TYPICAL FLEXIBLE METAL DUCT TC, 2 CEILING DIFFUSER NO SCALE TRAM IF RE ROUND -SQUARE OR RECTANGULAR DUCT AS INDICATED - HARD CONNECTION TO AIR DEVICE CEILING r CEILING DIFFUSER 4)�PICAL DUCT l-O DIFFUSER CONNECTION NO SCALE design Heery International Inc. 4700 Millenia Boulevard, Suite 550, Orlando, Florida 32839 407.992.6300 EB 0005176 Seal: ���wIll1/1/ \\�e� D . S TA No 34 s � � 01 A. j GARY D.�STARRETT - PE #33443 I rA- Are, I Project No. 12010.00 M4,1 02012 B11 PK Architects, Inc. $DATE$ $TIME$ $FILEA$ oMA 0 �_AAdol N N 0 NI R C\- N 19 3-4"C 2"C 1 1 /2"C 2 1 /2" C SCOPE OF WORK ^'JLL B0;< 30VE CEILING --------- 1 I I I I I I I I 1 � 1 `---------------------- PULL BOX ABOVE CEILING DEMOLITION PLAN - OVERHEAD CONDUIT SCALE: %" = 1' - 0" DEMO NOTES: 1. REMOVE ALL OVERHEAD CONDUIT & PULL BOXES FROM THIS PLAN. CONTRACTOR TO SAVAGE CONDUIT & BOXES FOR THIS 'DROJECT OR THERE USE. ELECTRICAL SYMBOLS WIRING DEVICES: DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) IN WALL +18" OR AS NOTED. IG = (NEMA 20-R) WITH ISOLATED GROUND TL = TWIST LOCK TYPE S = SECURITY TYPE COVER AND SCREWS EQUAL TO FAILSAFE #SSB1-1D QUADPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) IN WALL +18" OR AS NOTED. IG = (NEMA 20-R) WITH ISOLATED GROUND TL = TWIST LOCK TYPE S = SECURITY TYPE COVER AND SCREWS EQUAL TO FAILSAFE #SSB1-1 D DOUBLE DUPLEX RECEPTACLE ( QUAD) ON EMERGENCY, CRITICAL OR LIFE SAFETY CIRCUIT AS INDICATED BY HOME RUN. LIGHTING FIXTURES: 2x4 ® 1x4 FLUORESCENT FIXTURE AS SPECIFIED I--o-� STRIP CONNECTED TO NORMAL POWER. ❑O 2x2 ® 1x4 FLUORESCENT FIXTURE AS SPECIFIED I--o-� STRIP CONNECTED TO EMERGENCY OR CRITICAL POWER. 2x2 ® DOWN LIGHT AS SPECIFIED. CONNECTED TO EMERGENCY OR CRITICAL POWER. CONDUIT, RACEWAYS AND LIGHTING: CONDUIT CONCEALED IN WALL OR CEILING CONSTRUCTION COMMUNICATIONS SYSTEMS: INFORMATION MANAGEMENT (IMO) WALL MOUNTED +18" ABOVE FLOOR OR AS NOTED. NURSE CALL SYSTEMS: NURSE CALL DOME LIGHT - NUMERAL INDICATES TYPE -'Z' AFTER NUMERAL INDICATES ZONE DOME LIGHT. DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) � CODE BLUE CALL STATION - IN WALL +18" OR AS NOTED. ON EMERGENCY, CRITICAL 'PB' INDICATES PUSH BUTTON OR LIFE SAFETY CIRCUIT AS INDICATED BY HOME RUN ® EXIT LIGHT, CEI�_ING MOUNTED, ARROW DIRECTION 'FS' INDICATES FOOT SWITCH O IG = (NEMA 20-R) WITH ISOLATED GROUND AS INDICATED PLAN. CONNECTED TO LIFE SAFETY +42" ABOVE OF FLOOR OR AS NOTE. TL = TWIST LOCK TYPE OR LEGALLY REQUIRER POWER. S = SECURITY TYPE COVER AND SCREWS FIRE ALARM SYSTEMS: EQUAL TO FAILSAFE #SSB1-1D SINGLE POLE WALL SWITCH. LOWER CASE LETTERS meCHIME WITH LIGHT AS ONE ASSEMBLY - INDICATE FIXTURES ASSOCIATED WITH SWITCH. WALL MOUNTED @ + 80 ABOVE FLOOR MOUNT AT +48" UNLESS NOTED OTHERWISE. REUSE EXIST. CUT IN DOUBLE DUPLEX BOX DOUBLE TO REPLACE SINGLE BOX DUPLEX BOX 4 2 6 1 11 C1-4 11 r11 11 1LN1-2 1LC I 1 1LC1-1 I 2 +18„ 2 1LC1-2 SCOPE OF WORK 1LC1-8 1LC1-7 1 8 1 LC 1-9 1 1LC1-5 1LN 5� - � 3 1 8 3 5 1LN1-3 � 1 `----------------------- POWER PLAN SCALE: %" = 1' - 0" GENERAL NOTES: 1. PREFORM WORK IN CONFORMANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE BUILDING CODES AS INTERPRETED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 2. THE EXISTING CONDITIONS ARE SHOWN AS ACCURATELY AS FIELD CONDITIONS WOULD PERMIT. BIDDERS SHALL THOROUGHLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE & VERIFY ALL EXISTING CONDITIONS. THE CONTRACTOR SHALL REPORT TO THE ARCHITECT/ENGINEERING FIRM, BEFORE SUBMITTING A BID, ANY CONDITIONS WHICH MIGHT MAKE INSTALLATION OF REQUIRED EQUIPMENT A PROBLEM. NO CONSIDERATION OR ALLOWANCE WILL BE GRANTED FOR FAILURE TO INVESTIGATE CONDITIONS OR MISUNDERSTANDINGS OF THE CONTRACTURAL REQUIREMENTS. 3. IT IS THE INTENT OF THESE DRAWINGS TO CALL FOR FINISHED WORK, TESTED & READY FOR OPERATION. THE WORD "PROVIDE" MEANS "FURNISHED & INSTALL COMPLETE & READY FOR USE". 4. SEAL ALL FLOOR & FIRE -RATED WALL PENETRATIONS WITH UL APPROVED FIREPROOFING MATERIALS. 5. PROVIDE MINIMUM #12 AWG WIRE SIZE AND %" CONDUIT FOR ALL BRANCH CIRCUITRY. UNLESS OTHERWISE NOTED. 6. MOUNTING HEIGHTS GIVEN ON ELECTRICAL DRAWINGS ARE FOR BIDDING PURPOSES ONLY. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR MOUNTING HEIGHTS OF ALL WIRING DEVICES & EQUIPMENT JUNCTION BOXES. WHERE DISCREPANCIES OCCUR BETWEEN ELECTRICAL & ARCHITECTURAL DOCRMENTS, THE ARCHITEC--URAL ELEVATIONS TAKE PRECEDENCE. 7. FOR ACTUAL LOCATION OF CEILING MOUNTED LIGHTING FIXTURES, SEE ARCHITECTURAL REFLECTED CEILING PLANS. 8. CAREFULLY COORDINATE ALL ROUGH -IN REQUIREMENTS FOR OWNER FURNISHED EQUIPMENT WITH OWNER & EQUIPMENT SUPPLIERS. 9. PROVIDE A GREEN INSULATED GROUNDING CONDUCTOR FOR ALL BRANCH CIRCUITS. GROUND CONDUCTORS ARE NOT SHOWN IN WIRING DESIGNATION. 10. EACH TELEPHONE OUTLET SHALL HAVE ONE DOUBLE GANG BOX WITH SINGLE GANG PLASTER RING AND ONE 3/4" CONDUIT TO NEAREST CORRIDOR CABLE TRAY SYSTEM. SELECTED OUTLETS MUST BE LOCATED ABOVE OR IN CASEWORK RESPECTIVELY. CHECK ARCHITECTURAL ELEVATIONS, CASEWORK AND EQUIPMENT DRAWINGS. 11. EACH INFORMATION MANAGEMENT OUTLET (IMO) SHALL HAVE ONE DOUBLE GANG BOX WITH SINGLE GANG PLASTER RING & ONE, 1" CONDUIT TO NEAREST CORRIDOR CABLE TRAY SYSTEM. SELECTED OUTLETS MUST BE LOCATED ABOVE OR IN CASEWORK RESPECTIVELY. CHECK ARCHITECTURAL ELEVATIONS, CASEWORK & EQUIPMENT DRAWINGS. PANEL 1 LN 1 (NORMAL) PANEL 1LC1 (CRITICAL) DUPLEX TO CRITICAL Project No. 12010.00 ELI $DATE$ $TIME$ $FILER$ ©2012 HH/PK Architects, Inc. N N N \ O M N V- O O Eel Nl W-3 g 01 RELOCATE EXISTING SWITCHES INSTALL IN INDIVIDUAL BOXES. --------— — — — — — — — — — — I lLC1-3— EX EX I 3 3 3 FA 1 I I I 1LN1-1 FB EXISTING 1 3 3 3 FA DOWNLIGHTS I 1 (8) REUSED FA 1 1LC1-1 1 3 3 I SCOPE OF WORK -A LLEX 1 1 1 1 FB j FA FA FA FB 1 I I l 1 --- ---------——————— — — — — — — EXISTING 2 X 2 FIXTURES EX (6)REUSED LIGHTING PLAN SCALE: %" = l' - 0" EX SCHEDULES OF LIGHTING EQUIPMENT & LAMPS FIX. TYPE MANUFACTURER CATALOG NUMBER LAMPS TYPE OF FIXTURE MOUNTING NOTES INCAND. FLUOR. MISC. REC SUR SUS A EXISTING 100 W DOWNLIGHT X 120V. FA EXISTING 2-17 W 2 X 2 GRID TROFFER X 120V. T-8 FB EXISTING 4-32 W 2 X 4 GRID TROFFER X 120V. T-8 W ALKCO ERG-12-FL-2-DS 2-6W X-RAY IN USE X 120V. X-RAY IN USE T-5 NOTE # 2 NOTE # 1 NOTE # 3 +48" CB CB I 1 A +48111 S I I I 1 NOTE # 5 NOTE # 4 +18" 1 +18" +18" 1 SCOPE OF WORK- i ±48" y r I NOTE # 5 +48" 1 +1811 - 1 +48" 1 I I � 1 `----------------------- COMMUNICATION PLAN SCALE: %" = 1' - 0" NOTES: 1. EXISTING FIRE ALARM CHIME STROBE, REPLACE W / NEW ADA COMPLIANT / STROBE. 2. EXISTING NURSE CALL CODE BLUE STATIONS REUSED. 3. EXISTING SPEAKER FOR PAGING REUSED. 4. REUSE EXISTING IMO'S VERIFY CABLE PULL W / OWNER. 5. NEW IMO'S VERIFY CABLE PULL W / OWNER. Project No. 12010.00 $DATE$ $TIME$ $FILEA$ E192 02012 RH/PK Architects, Inc. N et- N _ o O EXISTING IISCONNE CT: SILO PANEL: 1 LC1 LOCATION: ROOM # 201 MTG. FLUSH VOLT: 120/208 BUS AMPS: 100 AIC: 10000 (CRITICAL) S.N.+GRND BUS SCA: - PHASE PHASE VOLT TRIP POLE A B C A B C POLE TRIP VOLT LTG R M # 201 & #202 120 20 1 450 y T 1 2 360 1 20 120 REC R M # 200 LTG R M # 200 120 20 1 E' 320 - 3 4 360 1 20 120 REC R M # 200 REC R M # 200 120 20 1 360 5 6 F 360 1 20 120 REC R M # 200 REC R M # 200 120 20 1 180 J 7 8 360 RF 1 20 120 REC R M # 202 REC R M # 200 120 20 1 180 N.; 9 10 180 �. 1 20 120 REC R M # 201 REC R M # 201 120 20 1`.. 360 11 12 - 360 1 20 120 REC R M # 200 SPARE 120 20 1 13 14 1 20 120 SPARE SPARE 120 20 1 t K, 15 16 1 20 120 SPARE SPACE 120 1 . 17 18 :gib} 1 120 SPACE SPACE 120 1 _A 19 20 r _'_.. 1 120 SPACE SPACE 120 1 �r.x.: 21 22 "�}" �_ 1 120 SPACE SPACE 120 1 23 24 1 120 SPACE SPACE 120 1 25 26 £- 1 1 120 SPACE SPACE SPACE 120 120 1 1 ¢� r = 27 29 28 30 4 Y._ 1 1 120 120 SPACE SPACE SPACE 120 1 y 31 32 1 120 SPACE SPACE 120 1 jst_ . , 33 34 1 120 SPACE SPACE 120 1 "Y- 35 36 1 120 SPACE SPACE 120 1 :M1 37 r38_ 1 120 SPACE SPACE 120 1 i? 39 40 w 1 120 SPACE SPACE 120 1 �- 41 42 � ; � ��, 1 120 SPACE CONN SUB PNL LOAD 0.0 KVA V.A. PHASE 'A" 1350 V.A. PHASE "B" 1040 V.A. PHASE "C"' 1440 DEM SUB PNL LOAD 0.0 KVA TOTAL CONN LOAD 3.5 KVA " WESTINGHOUSE PANEL to TOTAL D E M LOAD 3.5 KVA TRANSFORMER SCHEDULE — DRY TYPE PLAN KVA PRIMARY SECONDARY TAPS REMARKS MARK RATING VOLTS PH CONDUCTORS CONDUIT VOLTS PH CONDUCTORS CONDUIT % REG. NO.(+) NO.(-) T-30 30 480 3 3-#8,1-#10 GRND. 1" 120/208 3 4-#2,1-#8 GRND. 1 2 �" 2 4 PROVIDE RUBBER ISOLATION PADS TO EXISTING KOHLER GENERATOR 750 kw, 480 VOLT, 30, 60 HZ. EXISTING 277/480 VOLT SWBD, 30,4 WIRE (NORMAL) TO UTILITY XFMR TO EXISTING CATERPILLAR GERNERATOR 750 kw, 480 VOLT, 30, 60 HZ. AIC: 50,000 SCA:45,920 AIC: 42,000 1200 a- 800 AMP 0 3P o� 800 800 3P 3P SWBD MDP GDP 143/0 GRND. 2- EXISTING GENERATOR DISTRITUTION PANELS 277/480 VOLT, 30,4 WIRE (EMERGENCY) TO UTILITY XFMR 3PA EXISTING 277/480 VOLT SWBD 30,4 WIRE (NORMAL) AIC: 42,000 1200 AMP 800 3P EDPA AIC: 50,000 SCA: 48,720 800 a; AMP Co SWBD MDP EDP 143/0 GRND. 2 SETS OF 4-500 MCM & 141/0 GRND., IN 24"C. 4-500 MCM & 143 GRND, IN 4"C. [AMP0 EXISTING DISTRIBUTION PANEL 277/480 VOLT. 30.4W. (CRITICAL) `" IL E 400A 3P ATS-ECB AIC: 42,000 800A ECB SCA:30,068 AIC: 42,000 SCA: 35,180 EXISTING 480 VOLT, 30,4 POLE ATS (CRITICAL BRANCH) 2 SETS OF 4-500 MCM & 141/0 GRND., IN 24"C. 4-500 MCM & 143 GRND, AIC: 42,000 IN 4"C. EXISTING 480 VOLT N 30,4 POLE ATS L (CRITICAL BRANCH) 400A E 3P AIC: 42,000 ATS-1A SCA:32,918 400A EXISTING EMERGENCY DISTRIB. PANEL 277/480, 30, 4 W. (EMERGENCY) CEP 1 1 � moo 1 1 1 1: i- 11 1 1111 1 - a - 1 • a MZ 1 l i 1 1i1 1 1 -a EXISTING DISTRIBUTION PANEL 277/480 VOLT, 30, 4W. (CRITICAL) EXISTING DISTRIBUTION PANEL 277/480 VOLT, 30, 4W. (NORMAL) 800 AMP 50A DIA 3P AIC: 35,000 GDP SCA: 23,191 — 400 AMP 50A DIA 3P EC AIC: 35,000 SCA:15,908 NOTE #3 AIC:10,000 AIC:10,000 AIC:10,000 SCA:8,178 to Co A Ca T-30 W Ll T-30 7— 1---l-#8GRND. 148 GRND. NOTE #3 443/0 & 144 GRND., IN 22"C. NOTE #1 AIC:10,000 NOTE #2 443/0 & 144 GRND., IN 2 2"C. AIC: 35,000 400 SCA:14,312 AMP AIC: 10,000 OHM EXISTING DISTRIBUTION PANEL 277/480 VOLT, 30, 4W. (CRITICAL) NOTES: 1. MAIN BREAKER O FEEDING NEW CATH LAB EQUIPMENT CHANGES SIZE FROM 80A/3P TO 125A/3P (SQUARE D TYPE LE). THE EXISTING FEEDER SIZE WILL REMAIN THE SAME SIZE AS INDICATED. THE BREAKER IN EXISTING PANEL "lHX1" WILL CHANGE FROM AN 80A/3P TO 125A/3P (SQUARE D TYPE LE). GRND FLR. 2 PANELS "lLN1" (NORMAL) & "1LC1" (CRITICAL) WILL BE RE - FED FROM NEW SOURCES AS INDICATED. SEE NEW PANELBOARD SCHEDULES ON DRAWING E3.1. 3. THESE NEW TRANSFORMERS FEED EXISTING PANELS "lLN1" & "1LC1". NOTE NEW PRIMARY AND SECONDARY BREAKERS OFF THESE TRANSFORMERS. THE 50A/3P SHALL BE SQUARE D TYPE HJ & 100A/3P ENCLOSED CIRCUIT BREAKERS SHALL BE SQUARE D TYPE HD. ELECTRICAL RISER DIAGRAM NO SCALE TO NEW CATH LAB EQUIP. 2ND 1 ST FLR1 design Heery International Inc. 4700 Millenia Boulevard, Suite 550, Orlando, Florida 32839 407.992.6300 EB 0005176 Seal:HARD -V'.STATE O'F W 'ice '//�SS1O N A�- �? \ ////I11111\ � 5 19- l2 JONATHAN R. CANDOR - PE #49493 Project No. 12010.00 E301 © 2012 BH/PK Architects, Inc. $DATE$ $TIME$ $FILEA$ t m 9 0 N o N', E EF 9 12 ENLARGED CATH LAB SCALE: %" =1' - 0" A DETAIL E4.1 NOT TO SCALE B DETAIL E4.1 NOT TO SCALE FINISHED CEILING LINE ( TYPICAL ) FINISHED FLOOR LINE ( TYPICAL ) TERMINAL SCHEDULE ( CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) ITEM DESCRIPTION FACILITY TO DETERMINE 112.5 KVA, 480 VAC, 3 PHASE, POWER SOURCE LOCATION FOR TEAL POWER CONDITIONER. O NEMA 1, 480VAC, THREE PHASE, 5 WIRE, FRONT OPERATED, CIRCUIT BREAKER ENCLOSURE WITH GROUND ACCESSORIES. ENCLOSURE SHALL CONTAIN ONE 100 AMP, 3 POLE, THERMAL MAGNETIC CIRCUIT BREAKER WITH SHUNT TRIP DEVICE. FLUSH MOUNT IN WALL WHERE SHOWN. LOCATE TOP OF ENCLOSURE 6'- 0" A.F.F. NOTE: EC SHALL ENSURE THAT LUGS ARE LARGE ENOUGH TO FACILITATE OVERSIZED INCOMING CABLES REQUIRED BY X-RAY EQUIPMENT REFER TO " INCOMING WIRE SIZE " NOTES. © 4" X 2" SWITCH BOX. PROVIDE N.O./N.C. SWITCH WITH RED MUSHROOM HEAD AND AN " EMERGENCY OFF " NAME PLATE. FLUSH MOUNT IN WALL WHERE SHOWN. LOCATION BOX CENTER LINE 6'-0" A.F.F. EXACT NUMBER AND LOCATION TO BE DETERMINED BY CUSTOMER. INSTALL ONLY IF REQUIRED BY PREVAILING CODE OR IF REQUIRED BY CUSTOMER. OD 8" X 3" WIDE GROMMETED CABLE ACCESS HOLE IN BOTTOM OF WIRE TROUGH. LOCATE BOTTOM OF TROUGH 20" A.F.F. CABLE ACCESS FOR THE IMAGING CABINET. REFER TO DETAIL ON SHEET E ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. OC 8" X 3" WIDE GROMMETED CABLE ACCESS HOLE ON TOP OF WIRE TROUGH. LOCATE TOP OF TROUGH 24" A.F.F. REFER TO DETAIL ON SHEET E CABLE ACCESS FOR THE FLAT PANEL MONITOR(S), MOUSE / KEYBOARD; X-RAY CONTROL CONSOLE; OPTIONAL DVD BURNER. ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. OE 8" X 3" WIDE GROMMETED CABLE ACCESS HOLE IN BOTTOM OF WIRE TROUGH. LOCATE BOTTOM OF TROUGH 20" A.F.F. CABLE ACCESS FOR THE X-RAY POWER SUPPLY CABINET. REFER TO DETAIL ON SHEET E ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. E1 12" X 12" X 4" DEEP JUNCTION BOX SURFACE MOUNT ON WALL WHERE SHOWN. LOCATE BOTTOM OF JUNCTION BOX 2'-8" A.F.F. CONNECTION BOX FOR 480 VAC. THREE PHASE POWER TO TEAL POWER CONDITIONER. EC SHALL PROVIDE ONE 1 2" C. SEAL TITE AND ASSOCIATED CONNECTORS BETWEEN TEAL UNIT AND BOX El. 0 OPEN END OF 5" C. CHASE NIPPLE TERMINATED FLUSH WITH FINISHED FLOOR WHERE SHOWN. CABLE ACCESS FOR THE FLOOR MOUNTED POSITIONER. CHASE NIPPLE CONNECTED TO WIRE TROUGH LOCATED BELOW THE FINISHED FLOOR. JO 8" X 3" WIDE GROMMETED CABLE ACCESS HOLE IN BOTTOM OF WIRE TROUGH. LOCATE BOTTOM OF TROUGH 20" A.F.F. CABLE ACCESS FOR THE ELECTRONICS RACK CABINET. REFER TO DETAIL ON SHEET E ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. OM 12" X 12" X 8" DEEP JUNCTION BOX FLUSH MOUNT IN CEILING WHERE SHOWN. PROVIDE ONE 2 2" C. CHASE NIPPLE / BUSHING CENTERED IN OVERSIZED REMOVABLE SPLIT COVERPLATE. CABLE ACCESS FOR CEILING SUSPENDED MONITORS. REFER TO COVERPLATE DETAILS. ON OPTIONAL DOOR ACTIVATED SWITCH SQUARE-D CAT - CLASS 9007 TYPE AO (OR EQUAL). ( TO BE INSTALLED ONLY IF REQUIRED BY PREVAILING CODE OR IF REQUESTED BY CUSTOMER). SWITCH SHALL BE LOCATED ON HINGE SIDE OF DOOR, OT OPEN ENDS OF TWO 2-1/2" DIA. CHASE NIPPLES TERMINATED FLUSH WITH FINISHED FLOOR WHERE SHOWN. CABLE ACCESS FOR THE PATIENT TABLE. CHASE NIPPLES CONNECTED TO WIRE TROUGH LOCATED BELOW THE FINISHED FLOOR. �W 4" X 4" X 2" DEEP JUNCTION BOX FOR THE " X-RAY IN USE " WARNING SIGN. EXACT LOCATION TO BE DETERMINED BY OTHERS. FLUSH MOUNT IN WALL OR CEILING REQUIRES HOUSE POWER. INSTALL ONLY IF REQUIRED BY PREVAILING CODE OR IF REQUESTED BY CUSTOMER ZO JUNCTION BOX LOCATE ABOVE THE FINISHED CEILING WHERE SHOWN. SIZE DEPENDENT ON MODEL OF SURGICAL LIGHT ORDERED VERIFY SIZE WITH INSTALLERS. PROVIDE COVERPLATE WITH 6'-0" LONG, 2" DIA. GREENFIELD. CABLE ACCESS FOR SURGICAL LIGHT POWER. MGB MINIMUM 18" LONG COPPER GROUND BUS BAR. CONSULT WITH EQUIPMENT REPRESENTATIVE REGARDING EXACT SIZE AND LOCATION. PROVIDE DRILLED AND TAPPED HOLES FOR GROUND WIRE ATTACHMENT. REFER TO BLOCK DIAGRAMS. NOTE: REFERENCE TO " SEALTITE " BRAND MEANS REDUNDANT GROUND, PVC COATED, FLEXIBLE METAL CONDUIT. NOTE: THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR DIVIDING ALL JUNCTION BOXES AND CONNECTING TROUGHS TO MEET LOCAL AND FLORIDA AHCA REQUIREMENTS. ELECTRICAL TAG IDENTIFICATION (CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) 1� USE 4" CONDUIT. 20 NOT USED. 30 10" x 32" DEEP SURFACE MOUNTED VERTICAL RISER. CONNECT TO HORIZONTAL WIRE TROUGH AND WIRE TROUGH LOCATED BELOW THE FLOOR (USE 45" SECTION). REFER TO TROUGH NOTED AND ELEVATIONS. ® 10" x 32" DEEP SURFACE MOUNTED HORIZONTAL WIRE TROUGH. CONNECT TO VERTICAL RISER AND TERMINATE WHERE SHOWN. REFER TO TROUGH NOTES AND ELEVATIONS. ® PROVIDE VPN ACCESS TO THE INTERNET OR A SINGLE MODEM TELEPHONE LINE IN THE WALL FOR SERVICEABILITY PURPOSES. THE RJ11 LINE MUST BE A DEDICATED DIRECT IN DIAL (DID) VOICE - GRADE TELEPHONE LINE WITH ACCESS LOCATED NEAR DIGITAL PC ELECTRONICS CABINET. DO NOT CONNECT TO FACILITY PBX SYSTEM. FLUSH MOUNT IN WALL. REFER TO ELEVATIONS. © PROVIDE ETHERNET CONNECTION. EC SHALL CONSULT WITH END USER REGARDING TYPE OF CONNECTOR (e.g.. RJ-45/CAT-5, FIBER OPTICS, BNC/COAX, ETC.). REFER TO DICOM NOTES. PROVIDE ALL HARDWARE NECESSARY INCLUDING COVER PLATES, CONECTORS AND INTERCONNECTING CABLES. FLUSH MOUNT IN WALL. REFER TO ELEVATIONS. ol Are, 0&/l- r/mOv- wl Project No. 12010.00 E4. I 02012 BH/PK Architects, Inc. $DATE$ $TIME$ $FILER$ 9 i la N 0 O Ez ` a N O 15 ------>>(Z) (W) II.._------------------------- Illll POWER VAULT \111 y--- ->> OR DRIVEN 7 I I I IIIII GROUND ROD illlll 4 � � (IIIII <E - — - ---------- — (IIIII------------------ III1 -�♦ I c DETAIL E4.2 NOT TO SCALE FINISHED CEILING LINE ( TYPICAL ) D1 RACEWAY & WIRING SCHEDULE (CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) RUN # FROM TO SIZE REMAKS 1O 480 VAC, 3 - PHASE OA VARIES REFER TO "INCOMING WIRE SIZE WITH TEAL PCDU - OFF POWER CONDITIONER" NOTES. SOURCE EC SHALL CONNECT BOTH ENDS. 2O AO E1 1/" 3-#lAWG,1-#AWG NEUTRAL AND 1-#AWG GROUND. EC SHALL CONNECT AT (A) AND CONNECT TO INPUT POWER TERMINAL IN TEAL POWER CONDITIONER WITH SEALTITE CONDUIT BETWEEN JUNCTION BOX (El) AND REAR OF TEAL UNIT. O © O 12" 2-#14AWG PLUS GROUND. EC SHALL CONNECT TO SHUNT TRIP DEVICE IN (A) AND CONNECT "EMERGENCY OFF" SWITCH IN BOX CONDUIT (B). O DRIVEN GROUND VERTICAL RISER 12" 1-#1/OAWG GROUND (WELDING CABLE). EC SHALL CONNECT TO DRIVEN GROUND ROD AND TO COPPER BUS BAR REFER TO BUS BAR BLOCK DIAGRAM. ROD CONDUIT (MGB). 1211 2-#14AWG PLUS GROUND. EC SHALL CONNECT TO DOOR INTERLOCK SWITCH AND LEAVE O O O TAILS AT (J) PASS THROUGH BOX (W). CONDUIT INSTALL ONLY IF REQUIRED BY PREVAILING CODES OR REQUESTED BY CUSTOMER. O VERTICAL 12" 2-#14AWG PLUS GROUND. EC SHALL CONNECT TO "X - RAY IN USE" WARNING SIGN AT BOX (W) AND LEAVE TAILS AT (E). EC SHLL INSURE NO LIVE WIRES IN (E). RISER CONDUIT INSTALL ONLY IF REQUIRED BY PREVAILING CODES OR REQUESTED BY CUSTOMER. O ® VERTICAL THREE 2-2" OMEGA FURNISHED CABLES TO BE INSTALLED BY X - RAY EQUPMENT INSTALLERS. CONDUIT FOR MONITOR INTERCONNECT CABLES. RISER CONDUITS EC SHALL LEAVE PULL STRINGS. O © „ MOUNT CONDUIT FLUSH WITH THE FINISHED FLOOR LOCATED WHERE SHOWN AND CONNECTED TO WIRE TROUGH BELOW THE FLOOR. TROIUGH CHASE NIPPLE CONDUIT FOR C - ARM CABLES. O WIRE TWO 2-2" MOUNT CONDUIT FLUSH WITH THE FINISHED FLOOR LOCATED WHERE SHOWN AND CONNECTED TO WIRE TROUGH BELOW THE FLOOR. TROUGH CHASE NIPPLE CONDUIT FOR C - ARM CABLES. 10 VARIES VARIES VARIES OMEGA FURNISHED CABLES TO BE INSTALLED BY X - RAY EQUIPMENT INSTALLERS. E.C. SHALL PROVIDE AND INSTALL 3-#lAWG,141 NEUTRAL AND 1-#6AWG GROUND. EC X - RAY TEAL 12" SHALL CONNECT TO CIRCUIT BREAKER ON LOAD SIDE OF TEAL UNIT AND CONNECT TO 11 GENERATOR UNIT SEALTITE INPUT POWER TERMINALS IN X - RAY GERNERATOR CABINET WITH SEALTITE, PLUS TWO CONNECTORS, BETWEEN TEAL UNIT AND REAR OF X - RAY GENERATOR. E.C. SHALL PROVIDE AND INSTALL THE FOLLOWING: 2-#10AWG AND 1-#10AWG GROUND. RACK TEAL 12" EC SHALL CONNECT TO CIRCUIT BREAKER ON LOAD SIDE OF TEAL UNIT AND CONNECT TO 12 CABINET UNIT SEALTITE INPUT POWER TERMINALS IN 1-100 RACK CABINET WITH SEALTITE, PLUS TWO CONNECTORS, BETWEEN TEAL UNIT AND REAR OF RACK CABINET. RACK TEAL 12" E.C. SHALL PROVIDE AND INSTALL 241 OAWG GROUND. EC SHALL CONNECT TO 15 AMP, 1 P, CB IN 13 CABINET UNIT SEALTITE TEAL UNIT (SURGICAL LIGHT) AND LEAVE 10 TAILS AT RACK CABINET WITH SEALTITE, PLUS TWO CONNECTORS, BETWEEN TEAL UNIT AND REAR OF RACK CABINET. IMAGING TEAL 12" 2-#14AWG PLUS GROUND. EC SHALL COANNECT TO 20 AMP, 1 P, CB IN TEAL UNIT 14 CABINET UNIT SEALTITE (IMAGING CABINET). CONNECT TO TEAL UNIT WITH A 6 FT. PIECE OF 2" DIA. SEALTITE. 15 O VERTICAL RISER Y4" 2414AWG PLS GROUND. EC SHALL CONNECT TO SURGICAL LIGHT AND LEAVE 1 O' TAIL AT RACK CABINET. CONDUIT SPECIAL ELECTRICAL NOTES NOTES: SEE ATTACH OMEGA MEDICAL IMAGING DRAWINGS FOR DETAILED EQUIPMENT ON CONTRACTOR FURNISHED / OMEGA MEDICAL IMAGING FURNISHED. ALL JUNCTION BOXES, CONDUIT, DUCT, DUCT DIVIDERS, SWITCHES, CIRCUIT BREAKERS, ETC., ARE TO BE SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR. CONDUIT AND DUCT RUNS SHALL BAVE SWEEP RADIUS BENDS. CONDUIT AND DUCT ABOVE CEILING OR BELOW FINISHED FLOOR MUST BE INSTALLED AS NEAR TO CEILING OR FLOOR AS POSSIBLE TO REDUCE RUN LENGTH. GROUNDING 1. PROVIDE REDUNDANT GROUNDING OF ALL EQUIPMENT. 2. PROVIDE GROUND BUSHINGS OF ALL NIPPLES. 3. PROVIDE GROUND HUMPERS AT ALL DUCT JOINTS. 4. ALL OMEGA MEDICAL IMAGING CABINETS MUST BE CONNECTED TO THE DUCT OR JUNCTION BOXES WITH DIRECT BONDING OR HUMPER WIRES. 5. PROVIDE GROUND WIRE FROM DUCT OR JUNCTION BOXES TO T.V. MONITOR OR X - RAY TUBE UNIT. SEPARATIONS 1. ALL CABLES MUST BE SEPARATED BY VOLTAGE MARKED ON CABLES AND BY CLASS FROM OTHER CABLES. 2. DUCT DIVIDERS MUST AVE PROPER CROSS OVERS TO KEEP CLASS WIRING SEPARATED. 3. DIGTAIL WIRING, POWER, BUSS CABLES, COAXIAL CABLES MUST BE KEPT IN SEPARATE DUCT COMPARTMENT FOR ENTIRE RUN. 4. TERMINATION POINTS OF MONITORS, VCR'S, ETC. REQUIRE SEPARATE JUNCTION BOXES AND COVERPLATES FOR POWER AND VIDEO WITH BLANK COVERPLATES REQUIRED. INDIVIDUAL CONDUIT RUNS ARE SUGGESTED WHEN POSSIBLE. PROVIDE LISTING OF CABLE TYPES AND CLASS IN DUCTS AND CONDUIT FOR REVIEW AT FINAL INSPECTION. COORDINATE ALL WORD ON THIS SHEET WITH OMEGA MEDICAL IMAGING EQUIPMENT SUPPLIERS AND INSTALLERS. Project No. 12010.00 $DATE$ $TIME$ $FILEA$ E4*2 I©2012 BH/PK Architects, Inc. - — I — — — - u I CONDUIT TO 1/2" DIAMETER EACH 6' LONG LIVI11 VIAI VIAL RECESSED LIGHT FIXTURE WIRING TAP DETAIL NOT TO SCALE 4" SQUARE BOX 24" MINIMUM PLAN VIEW I � F i METAL STUD 24" MINIMUM :LBOARD RIGID OR EMT CONDUIT CONNECT .ES GROUNDING LUGS OF RECEPTACLES #12 WIRE DEEP 4 TAP SEE ARCHITECTURAL PLANS FOR WALL CONSTRUCTION BACK TO BACK ELECTRICAL OUTLETS DETAIL NOT TO SCALE JTLET BOX GROUNDING CONDUCTOR (GREEN) TAPPED HOLE IN BOX GROUNDING SCREW HEXAGON HEAD WASHER FACE SCREW ( TYPICAL ) TYPICAL RECEPTACLE WIRING METHOD NOT TO SCALE design Heery International Inc. 4700 Millenia Boulevard, Suite 550, Orlando, Florida 32839 407.992.6300 EB 0005176 Seal- 0 p4CHAR� /// 04 493 STATE Of ,' s810NAt- //111111O� JONATHAN R. CANDOR - PE #49493 Project No. 12010.00 E501 02012 BH/PK Architects, Inc. $DATE$ $TIME$ $FILER$ mim If'Or 141,070d, N 0 CD v N 0 I I cn o a N O Cn o 00 0 I .a 1 `I LDRP %a o i T Stan Lounge I i Womens Locker Scrubs Holding I I i ( CVICTIAI(_'')" QDDIAIVI CD hAA1K1 FIRE PROTECTION DEMOLITION PLAN SCALE: %" = 1' - 0" 1 Toilet i j i Toilet WL.j Staff Lounge Womens _ Locker L-_ i -.__ _... _.. _ _. — .•, � III __—T LDRP I II11 Closet Work ---- ----------- r - op -- - --- - —�-— - --- - - --- - - - -�. -. _. _�- _ � r C-Section I� _ I - - - - I F �- I SCOPE OF WORK I 1r, 1rr j I 4— li-------------------------- ELEC. =- 0, 1 � • I I 1 Ili � i� - -------- FIRE PROTECTION PLAN - NEW WORK SCALE. / = 1'- 0 TEE CLAMP, CENTER ON TILES P ON ARCH. REFLECTED CEILING I CEILING TILE CEILING GRID TEE - It SPRINKLER BRANCH LINE OUTLET (SPRINKLER OUTLET SHALL BE TO THE SIDE, NOT DOWN.) \ TYPICAL SPRINKLER HEAD FLEXIBLE PIPE OPTION 1" CAST II SCR. 90 E 1" CAST IRON SCR. 90 DEG. ELL OR TEE (AS REQ'D) SPRINKLER BRANCH LINE PIPING (SPRINKLER OUTLET MAY BE TURNED DOWN, DEPENDING ON SITUATION.) 1" PIPING TO PENDENT SPRINKLER HEAD LINE OF SUSPENDED CEILING u TYPICAL SPRINKLER HEAD —Z HARD PIPE OPTION SUPPLY DETAIL FOR SEMI RECESSED SPRINKLER HEADS NTS SPRINKLER SYMBOL DESCRIPTION SYMBOL SIZE TYPE RESP FINISH TEMP K-FACTOR • o % CONCEALED QR WHITE 165 5.6 NOTE: NOT ALL SYMBOLS SHOWN MAY BE REQUIRED FOR THIS PROJECT NOTES 1. THIS BUILDING SHALL BE PROTECTED THROUGHOUT BY AUTOMATIC SPRINKLERS. THE DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 13, LATEST ENFORCEABLE EDITION. 2. ADHERE TO AND OBTAIN ALL PERMITS, LICENSES AND ALL GOVERNMENT REQUIREMENTS. 3. ALL AREAS SHALL BE FIRE SPRINKLERED. THIS SHALL INCLUDE ELEVATOR EQUIPMENT ROOMS, ELEVATOR SHAFT PIT, ELECTRICAL ROOMS, TELEPHONE ROOMS, AND ANY CONCEALED SPACES OF COMBUSTIBLE CONSTRUCTION. 4. REFER TO ARCHITECTURAL REFLECTED CEILING AND ELECTRICAL LIGHTING DRAWINGS FOR CEILING DESCRIPTIONS AND HEIGHTS. 5. THE LOCATIONS OF SIAMESE CONNECTION, RISERS, FEED MAINS, CROSS MAINS AND BRANCH PIPING WHERE SHOWN ON THE DRAWINGS IS APPROXIMATE. FINAL LOCATION IS THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE IN COMPLIANCE WITH THE SPECIFICATIONS AND ALL APPLICABLE CODES OR REGULATIONS. 6. PROVIDE HEADS GUARDS FOR SPRINKLERS IN ELECTRICAL ROOMS, ELEVATOR MACHINE ROOMS AND ANY HEADS THAT ARE SUBJECT TO MECHANICAL DAMAGE AND/OR BELOW 7'-0" 7. NOT ALL PIPING, VALVES AND APPURTENANCES ARE SHOWN ON PLANS. REFER TO PIPING AND RISER DIAGRAMS, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. 8. INSPECTOR'S TEST CONNECTIONS SHALL BE PROVIDED FOR ALL ZONES SO THAT THE WATER FLOW SWITCH FOR EACH ZONE CAN BE TESTED. CONNECTIONS SHALL HAVE A MINIMUM 1 1/2 INCH OUTLET AND DRAIN VALVE LOCATED IN AN ACCESSIBLE LOCATION PIPED TO AN APPROVED LOCATION. 9. PROVIDE ACCESS PANELS 1*0 ALL VALVES ABOVE NON- ACCESSIBLE CEILINGS AND CHASES. 10. ALL VALVES ON THE FIRE PROTECTION SYSTEM TO BE ELECTRICALLY SUPERVISED. TYPE AND EXACT LOCATION OF FLOW AND SUPERVISORY SWITCHES SHALL BE ACCOMPLISHED BETWEEN THE DIFFERENT RESPONSIBLE TRADES. 11. PROVIDE A PERMANENTLY ATTACHED NAME TAG STATING THE REQUIRED DESIGN CRITERIA FOR EACH HYDRAULICALLY DESIGNED SYSTEM. 12. ALL SPRINKLER HEADS MOJNTED IN CEILING SHALL BE LOCATED A MINIMUM OF 4" AWAY FROM ANY WALLS, CEILING HEIGHT CHANGES OR ANY OTHER VERTICAL INTERSECTING STRUCTURAL SURFACE. 13. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK 48" OR WIDER. 14. PROVIDE ADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER TRADES, AND/OR TO MAINTAIN PROPER CLEARANCES. VERIFY STRUCTURAL, MECHANICAL, ELECTRICAL INSTALLATIONS TO AVOID OBSTRUCTIONS OR INTERFERENCE WITH FIRE PROTECTION PIPE ROUTING. 15. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS. FIRESTOPPING SHALL BE OF A U.L. LISTED ASSEMBLY. 16. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL DIFFUSERS, SPEAKERS, LIGHTING FIXTURES, CEILING SYSTEMS AND STRUCTURAL SYSTEM. 17. SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT. NO INSTALLATION SHALL BE PERMITTED UNTIL SPRINKLER SHOP DRAWINGS HAVE BEEN APPROVED. 18. DESIGN CRITERIA: A. ALL LIGHT HAZARD AREAS (OFFICES, TREATMENT ROOMS, ETC.) SHALL BE HYDRAULICALLY DESIGNED FOR A DENSITY OF 0.10 GPM/SQ. FT. OVER THE MOST HYDRAULICALLY REMOTE 1,500 SQ. FT. AND SHOULD INCLUDE A 100 GPM INSIDE HOSE STREAM ALLOWANCE. B. ALL ORDINARY HAZARD AREAS (MECHANICAL ROOMS, STORAGE AREAS, ETC.) SHALL BE HYDRAULICALLY DESIGNED FOR A DENSITY OF 0.20 GPM/SQ. FT. OVER THE MOST HYDRAULICALLY REMOTE 1,500 SO. FT. AND SHOULD INCLUDE A 100 GPM INSIDE HOSE STREAM ALLOWANCE AND A 150 GPM OUTSIDE HOSE STREAM ALLOWANCE. 20. UNLESS OTHERWISE NOTED, ALL SPRINKLER HEADS TO BE QUICK RESPONSE. LEGEND EXISTING PIPE design NEW PIPE Heery International Inc. 4700 Millenia Boulevard, PIPING TO BE Suite 550, REMOVED Orlando, Florida 32839 407.992.6300 NEW TO EXISTING EB 0005176 Seal: LIMIT OF REMOVAL "S S. Per, f �' No 44604 � � , r r*= o/ AIA JAME S. PETERKIN - PE #44604 U U O +f U Q Ln cc NQ W N •� 00 co CD co N N U C 0.�jm� — Cl) F O CID J � D N 'T o Y co 0 U 4J n N z 4-1 o co o C C 00 LL 0 L CD � N I o i � o 0 r Cz J Cll� U z Q Cn z O N U m LU -- O ICE o C� LU � O LL L_L Project No. 12010.00 F1- . 2 02012 BWPK Architects, Inc. $DATE$ $TIME$ $F/LEAS REVISI❑NS SHEET REV REVISION DESCRIPTION REP DATE NUMBER SHEET E3 INCOMING WIRE SIZE NOTES ON SHEET E3. ADJUSTED WIRE SIZE DKM 01.30.2012 [5] ACCORDING TO THE LOAD DROP PERCENTAGE AT 160 FOOT INCOMING WIRE LENGTH. SAVE MONEY AND REDUCE CONSTRUCTION TIME ( PRODUCTS LISTED BELOW ARE CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) FOR FACTORY DIRECT PRE NEGOTIATED DEEP DISCOUNTED PRICES ON: - TEAL POWER PRODUCTS CONTACT TOM FISHLER, P.E. 1-262-827-9101. TEAL ELECTRONICS INC., MEDICAL DIVISION 13740 PADDOCK PARKWAY, NEW BERLIN, WI 53151. - LEAD SHIELDING PRODUCTS CONTACT SAM SNYDER 1-800-680-1967. PITTS LITTLE CORPORATION 2711 ALTON ROAD, B I RM I N G HAM, AL 35210-1031 - ELECTRICAL WIRE TROUGH PRODUCTS CONTACT YOUR LOCAL AUTHORIZED SQUARE D DISTRIBUTOR AND MENTION THE FILE NAME (LOCATED AT THE BOTTOM RIGHT HAND CORNER OF THIS DRAWING); PROJECT NAME AND LOCATION. REFER TO "TROUGH NOTES". FOR ALL THE INDIVIDUALS WHO ARE CONCERNED ABOUT THE HIGH COST OF SINGLE ROOM CONSTRUCTION, GAMMA TECH, INC. HAS NEGOTIATED DEEP DISCOUNTED PRICING FOR THE PRODUCTS MENTIONED ABOVE. WE BELIEVING IN THE VALUE OF THESE PRODUCTS AND ENCOURAGE YOU TO TAKE ADVANTAGE OF THIS COST SAVING OPPORTUNITY. TO REALIZE THESE DISCOUNTS, SIMPLY REFERENCE THE FILE NAME LOCATED ON THE BOTTOM RIGHT OF THIS SHEET. PLANNING BY: SHEET LEGEND SHEET NUMBER SHEET DESCRIPTION Al SHEET LEGEND, RECEIPT OF DRAWINGS, DENOTED REVISIONS, QUOTES -LEAD SHIELDING PRODUCTS; TEAL POWER PRODUCTS. A2 GENERAL, ARCHITECTURAL, AND SUPPORT NOTES. A3 PROPOSED ROOM /SUPPORT LAYOUT. A4 PROPOSED UNISTRUT SUPPORT LAYOUT AND CONSTRUCTION NOTES. A5 C-ARM AND TABLE BASE MOUNTING DETAILS, B 1 PROPOSED OMEGA EQUIPMENT LAYOUT. COVERPLATE DETAILS. B^L EQUIPMENT SCHEDULE. D1-4 EQUIPMENT DETAILS. El ELECTRICAL LAYOUT. E2 TERMINAL SCHEDULE AND COVERPLATE DETAILS. E3 POWER, WIRING AND INCOMING WIRE SIZES NOTES. E4 ELECTRICAL LAYOUT AND SPECIFICATIONS. E5 ELECTRICAL ELEVATIONS. E6 TROUGH DETAILS AND NOTES. E 7 ELECTRICAL LAYOUT AND SPECIFICATIONS. E8 ELECTRICAL ELEVATIONS. E9 ELECTRICAL BLOCK DIAGRAMS; SURGICAL LIGHT DETAIL AND GROUND WIRE REQUIREMENTS. E 1 O DOOR SWITCH /WARNING LIGHT DETAILS; EXAMPLES OF TYPICAL X-RAY WARNING LIGHT CIRCUITS AND VARIOUS OPTIONS /CONSIDERATIONS. Nggice to the Corporation, Person(s) regarding the Computer Aided Design and Drafting (CADD) files enclosed. Acc p rhe CADD data is based on the following disclaimer which covers all CADD data received from Gamma Tech, Inc. gamma tec n 129 Wild Berry Lane Voice (910) 270-9787 Gamma Tech, Inc. makes no representation or warranties, express or implied, with respect to the reuse of the data provided herewith, Hampstead, NC 28443 Fax (910) 270-9767 regardless of its format or the means of its transmission. There is no guarantee or representation to the user as to the accuracy, currency, mail@gammatech.net www.gammatech.net suitability or reliability of this data for any purpose. The user accepts the data "as is", and assumes all risks associated with its use. By acceptance of this data, the user agrees not to transmit this data or provide access or any part of it to another party unless the user shall include with the data a copy of this disclaimer. Gamma Tech, Inc. assumes no responsibility for actual or consequential damage incurred as a result of any user's reliance on this data. Furthermore, electronic files on this media contain confidential and proprietary information that cannot be reproduced or divulged, in whole or in part, without written authorization from Gamma Tech, Inc. All sheets included shall be considered a complete set and may not be separated for any purpose. Any information contained in this set shall NOT be applied to other projects. Violation will result in prosecution under the full extent of the law. RECEIPT OF FINAL DRAWINGS THIS SIGNATURE REPRESENTS RECEIPT OF THIS SET OF FINAL PLANS. IT IS UNDERSTOOD THAT ANY DEVIATION FROM THESE DRAWINGS, DETAILS, AND SPECIFICATIONS, MAY ENCROACH UPON THE EQUIPMENT OPERATION, SERVICEABILITY, OR SAFETY GUIDELINES. ALSO, I AM AWARE THAT ANY CHANGES MADE AFTER THIS DATE COULD RESULT IN ADDITIONAL EXPENSES BEING INCURRED. NAME: DATE: U Q W LL 7 2 O IF11 W Z Q J CL W CD Z M J LL .. W O O M M M M M qqt N X F--I U- .0 V m ~LLI 0 LU F� J U r ti 00 ()�_ U U z CY) J Q L.L W o C) _LL z O �U) 2 W Cn 0 Z C� Q DRAWN BY: SCALE: Dave Moser None DATE: SHEET: 01.30.2012 FHZ122011 i GENERAL NOTES AT THEIR EXPENSE, THE CUSTOMER AND/OR THE CONTRACTOR WILL BE EXPECTED TO PROVIDE THE FOLLOWING (IF REQUIRED) PRIOR TO X-RAY EQUIPMENT DELIVERY AND INSTALLATION: 1. ANY ROOM REMODELING AND CONSTRUCTION - FLOOR CEILING AND WALLS MUST BE FINISHED BEFORE EQUIPMENT INSTALLATION CAN BEGIN. 2. INSTALLATION OF PROPER SPECIFIED POWER. 3. INSTALLATION OF LOAD CENTERS, BRANCH PANELS, CIRCUIT BREAKERS, JUNCTION BOXES, CONDUIT AND CABLE TRAYS AS SPECIFIED. 4. INTERCONNECTING WIRE AND CABLE AS SPECIFIED. 5. INSTALLATION OF WALL AND CEILING SUPPORT AND SUSPENSION FRAME WORK AS SPECIFIED. 6. FOR THE MOST PART CONVENIENCE OUTLETS ARE TO BE SPECIFIED BY OTHERS. OUTLETS REQUIRED BY EQUIPMENT WILL BE SPECIFIED. FOR EASE IN EQUIPMENT SERVICE, A MINIMUM NUMBER OF OUTLETS WILL BE DEPICTED. 7. ANY CEILING MOUNTED LIGHT FIXTURES, DIFFUSERS, VENTS, SMOKE/FIRE DETECTORS, SPRINKLER HEADS, HALON NOZZLES, ETC. SHALL NOT EXTEND MORE THAN 1/2" BELOW THE FINISHED CEILING. 8. ANY PLUMBING REQUIREMENTS. 9. INSTALLATION OF OPTIONAL WARNING LIGHT AND/OR DOOR INTERLOCK SWITCH AT ENTRANCE DOORS OF X-RAY ROOM TO BE COORDINATED WITH FACILITY, EQUIPMENT INSTALLERS, AND DESIGN TEAM. 10. ANY AIR CONDITIONING REQUIREMENTS. (HVAC - HEATING, VENTILATION, AIR CONDITIONING AND HUMIDIFICATION) 11. ALL ANCILLARY AND ACCESSORY ITEMS. 12. RADIATION PROTECTION REQUIREMENTS: THESE MUST BE SPECIFIED BY A QUALIFIED RADIATION PHYSICIST. 13. SHIELDING TESTING (LEAD OR EQUIVALENT): AFTER X-RAY EQUIPMENT HAS BEEN INSTALLED AND PLACED IN OPERATING CONDITION, THE SHIELDING SHALL, BE TESTED, AT THE OWNER'S EXPENSE, BY A CERTIFIED HEALTH PHYSICIST. 14. THE DECISION OF ACCEPTABILITY BY A HEALTH PHYSICIST SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THEREFORE, THE CONTRACTOR IS RESPONSIBLE FOR REPAIRS OR REPLACEMENT OF ALL DEFECTIVE WORK (INCLUDING WORK SUBSEQUENTLY AFFECTED) AND ADDITIONAL TESTS REQUIRED TO MEET THE SATISFACTION OF THE HEALTH PHYSICIST. 15. LIABILITY: THE EQUIPMENT REPRESENTATIVES OR THEIR PLANNER ASSUME NO RESPONSIBILITY FOR ANY CONSTRUCTION COSTS, WHETHER OR NOT RELATED TO THE INSTALLATION OF X-RAY EQUIPMENT OR SITE PLANNING DOCUMENTS. NO WORK MAY BE PERFORMED OR MATERIALS FURNISHED AT THEIR EXPENSE UNLESS AUTHORIZED BY A SIGNED, FORMAL PURCHASE ORDER. ADDITIONALLY, A SITE INSPECTION SHALL BE CONDUCTED BY THE EQUIPMENT REPRESENTATIVES TO CONFIRM THE SITE'S READINESS PRIOR TO X-RAY EQUIPMENT DELIVERY. THIS INSPECTION SHALL BE PERFORMED WHEN NOTIFIED OF THE CONSTRUCTION'S COMPLETION. ARCHITECTURAL NOTES 1. GAMMA TECH'S SET OF DRAWINGS ARE FOR THE PURPOSE OF A LAYOUT PLAN ONLY - NOT FOR CONSTRUCTION. THE EQUIPMENT REPRESENTATIVES OR THEIR DESIGNER ARE NOT RESPONSIBLE OR LIABLE FOR ANY ERRORS OR OMISSIONS. GAMMA TECH'S DRAWINGS ARE FOR THE BENEFIT OF PURCHASER'S ARCHITECT OF CHOICE OR PROJECT MANAGER WHO SHALL ENSURE THAT ALL CONSTRUCTION COMPLIES WITH BUILDING CODES AND REGULATIONS THAT HAVE JURISDICTION. THOSE MAKING USE OF OR RELYING ON THIS MATERIAL ASSUMES ALL RISKS AND LIABILITY ARISING FROM SUCH USE OR RELIANCE. GAMMA TECH'S DRAWINGS ARE INTENDED TO PROVIDE THE CONSTRUCTION PARTICIPANTS WITH SPECIFICATION AND CONCEPTUAL INFORMATION ONLY. EVERY EFFORT HAS BEEN MADE TO CONFORM DETAILS TO THE ACTUAL EQUIPMENT EXPECTED TO BE INSTALLED. THE DESIGN TEAM SHALL EXTRAPOLATE PERTINENT -INFORMATION FROM THIS LAYOUT AND INCORPORATE INTO A WORKING SET OF CONSTRUCTION DRAWINGS OBSERVING ALL PREVAILING CODES. GAMMA TECH'S FLOOR PLAN WAS SCALED FROM PRINTS DRAWN BY OTHERS. ALL CONSTRUCTION PARTICIPANTS SHALL VERIFY AND ADJUST DIMENSIONS. CRITICAL DIMENSIONAL RELATIONSHIPS HAVE BEEN SUPPLIED. IT IS THE RESPONSIBILITY OF ALL CONSTRUCTION PARTICIPANTS TO ADHERE TO THESE DISTANCES. ALL DIMENSIONS ARE FROM FINISHED SURFACES UNLESS OTHERWISE NOTED. ARCHITECT SHALL VERIFY THAT ALL DOOR AND PASSAGEWAY SIZES ARE ADEQUATE FOR TRANSPORTING EQUIPMENT FROM EXTERIOR OF BUILDING INTO RESPECTIVE ROOMS. RECOMMEND COVERING OR REMOVING THRESHOLDS. 2. ALL SUPPLY DIFFUSERS SHALL NOT CAUSE DIRECT AIR CURRENTS ON PATIENTS OR OPERATORS. RECOMMEND 2' x 4' LAY -IN CEILING PANELS OF MATERIAL ACCEPTABLE TO CUSTOMER AND APPROVED BY PREVAILING CODES. LIGHTING FIXTURES, VENTS, ETC. TO BE FLUSH WITH FINISHED CEILING. 3. ARCHITECT AND ENGINEERS SHALL USE EXISTING ELECTRICAL AND STRUCTURAL ITEMS WHEN FEASIBLE. 4. ALL WORK, EXCEPT INSTALLATION OF DIAGNOSTIC IMAGING EQUIPMENT, IS TO BE DONE BY THOSE OTHER THAN THE EQUIPMENT REPRESENTATIVES. 5. SOME CONVENIENCES MAY BE REQUIRED BY CODE OR DESIRED BY CUSTOMER IN EACH RESPECTIVE ROOM (i.e., STORAGE, CABINETS, SINKS AND COUNTERS, ETC.) PROJECT MANAGER SHALL CONSULT WITH FACILITY REGARDING DESIRED CONVENIENCES. 6. THE SUPPLY VOLTAGE M'..'ST REMAIN RELATIVELY STABLE. ELECTRICAL POWER FOR X-RAY EQUIPMENT REQUIRES VERY LARGE CURRENTS FOR EXTREMELY SHORT TIMES. REFER TO ELECTRICAL NOTES. GROUNDING MUST CONFORM TO THE CURRENT CODE REQUIREMENTS. 7. VIEWING WINDOW TO BE 1/16" LEAD EQUIVALENT. RECOMMEND LARGE VIEWING WINDOWS TO BE TILTED 70 TO HELP ELIMINATE GLARE. IF TILTED 70 VIEWING WINDOW IS ACRYLIC, PROVIDE A SINGLE SHEET OF PLATE GLASS ON BOTH SIDES TO HELP PREVENT SCRATCHING. 8. NO ATTENTION HAS BEEN GIVEN TO SPECIFIC PLUMBING OR HVAC CONSIDERATIONS AFFECTED BY THE SCOPE OF THIS WORK. MECHANICAL ENGINEERING DRAWINGS TO BE DONE BY OTHERS. ELECTRICAL AND MECHANICAL DESIGNERS SHALL BE REQUIRED TO REVIEW THESE DRAWINGS TO HELP THEM GAIN AN UNDERSTANDING OF THE CONCEPT OF THIS WORK AND TO HELP MINIMIZE CONFLICTING CONSTRUCTION EFFORTS. ELECTRICAL ENGINEERING DRAWINGS TO BE DONE BY OTHERS. NO ATTENTION HAS BEEN GIVEN TO SPECIFIC BUILDING STRUCTURAL INTEGRITY. A PROFESSIONAL STRUCTURAL ENGINEER SHALL INSPECT FIELD CONDITIONS TO ENSURE THAT THE FACILITY SUPPORT STRUCTURE (e.g. WALLS, FLOORS, CEILINGS) CAN PROVIDE ADEQUATE SUPPORT FOR THE DIAGNOSTIC IMAGING EQUIPMENT DESCRIBED IN THE 'EQUIPMENT SCHEDULE'. STRUCTURAL ENGINEERING DRAWINGS TO BE DONE BY OTHERS. NO ATTENTION HAS BEEN GIVEN TO SPECIFIC SEISMIC ANCHORAGE CONSIDERATIONS AFFECTED BY THE SCOPE OF THIS WORK. ALL EXPENSES ASSOCIATED WITH SEISMIC TESTING AND COMPLIANCE SHALL BE THE RESPONSIBILITY OF THE FACILITY (END USER) OR THEIR RESPECTIVE CONTRACTORS OF CHOICE. IT IS STRONGLY RECOMMENDED THAT THE CUSTOMER CONSULTS WITH A PROFESSIONAL STRUCTURAL ENGINEER FAMILIAR WITH ALL PREVAILING SEISMIC REQUIREMENTS. SEISMIC ENGINEERING DRAWINGS TO BE DONE BY OTHERS. 9. THE EQUIPMENT REPRESENTATIVES MUST APPROVE DEVIATION FROM THESE PLANS IN WRITING PRIOR TO ANY CHANGES. SUPPORT NOTES ( CONTRACTOR FURNISHED -CONTRACTOR INSTALLED) THE EQUIPMENT REPRESENTATIVE OR THEIR DESIGNER IS IN NO WAY RESPONSIBLE FOR THE SUPPORT STRUCTURE FOR ANY OVERHEAD CEILING MOUNTED EQUIPMENT / DEVICES OR WALL MOUNTED EQUIPMENT / DEVICES. THIS IS THE RESPONSIBILITY OF THE CONSTRUCTION PARTICIPANTS. UNISTRUT: 1. ALL UNISTRUT, ALL STEEL WORK AND ALL OTHER PARTS NECESSARY TO SUPPORT CEILING MOUNTED TUBE HANGER OR OTHER CEILING SUSPENDED EQUIPMENT SHALL BE PROVIDED BY AND INSTALLED BY CONTRACTOR. CONSIDER INSTALLING UNISTRUT CHANNELS WALL TO WALL TO FACILITATE FUTURE EQUIPMENT. UNISTRUT CHANNEL SHALL BE PARALLEL, SQUARE AND IN SAME HORIZONTAL PLANE. THE SYSTEM IS TO BE CROSS BRACED VERTICALLY, HORIZONTALLY, AND DIAGONALLY TO ALLOW NO MOVEMENT AND A MAXIMUM OF 1/16" DEFLECTION. THE RECOMMENDED HEIGHT ABOVE THE FINISHED FLOOR TO THE BOTTOM TO THE UNISTRUT IS SPECIFIED ON THIS PLAN. 2. INTENTIONALLY LEFT BLANK. 3. CONTRACTOR SHALL SUPPLY CLOSURE STRIPS (P3184) FOR AREAS OF UNISTRUT EXPOSED AND WITHOUT MOUNTING UNITS. THE CLOSURE STRIPS SHALL BE INSTALLED AFTER THE OVERHEAD RAILS HAVE BEEN SECURED IN PLACE BY THE EQUIPMENT INSTALLERS. 4. METHODS OF SUPPORT FOR THE STEELWORK THAT WILL PERMIT ATTACHMENT TO STRUCTURAL STEEL OR THROUGH BOLTS IN CONCRETE CONSTRUCTION SHOULD BE FAVORED. DO NOT USE SCREW ANCHORS IN DIRECT TENSION. 5. DO NOT USE SCREWS TO FASTEN CEILING GRID TO UNISTRUT. AN ALTERNATE METHOD SUCH AS TACK, SPOT WELDING, ETC. SHOULD BE CONSIDERED. 6. ALL UNISTRUT MEMBERS HAVE BEEN COORDINATED WITH THE X-RAY EQUIPMENT. ANY DEVIATION FROM THIS PLAN MUST BE APPROVED BY SIGNATURE THROUGH THE EQUIPMENT REPRESENTATIVE. 7. IT IS STRONGLY RECOMMENDED THAT A STRUCTURAL ENGINEER, IN CONJUNCTION WITH UNISTRUT REPRESENTATIVES, COORDINATE ANY UNISTRUT SUPPORT STRUCTURE. SUPPORTS: 1. ALL UNITS THAT ARE WALL MOUNTED OR CEILING SUSPENDED ARE TO BE PROVIDED WITH SUPPORTS STRUCTURES WHERE NECESSARY. 2. ALL SUPPORTS STRUCTURES ARE TO BE PROVIDED BY THE FACILITY OR THEIR CONTRACTOR. 3. WALL SUPPORTS ARE TO BE HIDDEN WITHIN WALLS WHENEVER POSSIBLE. 4. WALL SUPPORTS MAY NOT BE REQUIRED IF WALL MATERIAL IS ADEQUATE FOR THE LOADS GIVEN (i.e.,BLOCK). CONSULTATION WITH A STRUCTURAL ENGINEER IS STRONGLY RECOMMENDED. 5. ALL SURFACE MOUNTED SUPPORTS ARE TO BE PAINTED THE SAME COLOR AS THE ADJACENT SURFACE OR CONSULT WITH FACILITY REGARDING ACCENT COLORS. FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: NONE SHEET: A -2 I I I I I I 111 '1 1 I I I I I I 1 cc N 24'-1 1 /2" 7'-8" PROPOSED ROOM AND OMEGA EQUIPMENT LAYOUT - A.4 (ROOM DIMENSIONS SHALL BE FIELD VERIFIED) (CONTRACTOR SHALL VERIFY LOCATION OF SUPPORT BEAMS AND JOISTS) COUNTERTOP - SLIDING SHELF 5 00 EQUIPMENT CLOSET NOTES: EACH EQUIPMENT CABINET HAS A MINIMUM AMOUNT OF SPACE AROUND IT THAT IS REQUIRED TO BE KEPT CLEAR SO THAT SERVICE MIGHT BE PERFORMED AND CABLES / METAL FLEX CONDUIT MAY BE CONNECTED AND DRAPED. EXACT CLEARANCE DIMENSIONS ARE DICTATED BY THE GREATER OF PREVAILING CODE OR THE MANUFACTURER'S SPECIFICATION. REFER TO NEC 110.26, EQUIPMENT DETAILS AND CONSTRUCTION NOTE #6 ON SHEET A-4. FACILITY: Florida Hospital Zephyrhills, FL IRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: 1 /4" = 1 ' SHEET: A 3 I I I LIP I I I I I 1 11 11' I ! I 1 I 1 11 1 1 I i 1 I 2'-1 5/8" 2'-2" 2'-2" 2'-2" 2'-2" 2'-2" I I I PROPOSED UNISTRUT SUPPORT LAYOUT (RECOMMENDED FINISHED CEILING HEIGHT IS 9'-011) CONSTRUCTION NOTES (CONTRACTOR FURNISHED -CONTRACTOR INSTALLED) QP-1001 UNISTRUT (OR EQUAL) FLUSH WITH FINISHED CEILING AND FIRMLY ANCHORED IN PLACE. EACH CHANNEL SHALL WITHSTAND A VERTICAL LOAD OF 100LBS. PER ANCHORAGE LOCATION, FULL LENGTH SHOWN. PAINT CHANNELS THE SAME COLOR AS THE FINISHED CEILING. REFER TO SUPPORT NOTES. LOCATION OF TWO P-1000 UNISTRUT (OR EQUAL).SUPPORTS FOR RADIATION SHIELD /SURGICAL LIGHT. ATTACH TO THE BOTTOM OF UNISTRUT CHANNELS #1. LOCATION AND LENGTHS DETERMINED BY CENTERLINES OF MOUNTING PLATE #5. OPEN CHANNEL MUST FACE FLOOR. PAINT CHANNEL THE SAME COLOR AS THE CEILING. EACH CHANNEL TO SUPPORT 240 POUNDS STATIC LOAD. REFER TO SUPPORT NOTES. QOMEGA C-ARM BASE PLATE: REFER TO MOUNTING DETAILS. VERIFY LOCATION WITH FULL SIZE TEMPLATE. CONTRACTOR SHALL DRILL ALL ANCHORING HOLES AND ASSIST OMEGA EQUIPMENT INSTALLERS WITH THRU BOLTING. CONTRACTOR IS RESPONSIBLE FOR FLOOR INTEGRITY AND BASE PLATE ANCHORING. OMEGA TABLE BASE PLATE: REFER TO MOUNTING DETAILS. VERIFY LOCATION WITH FULL SIZE TEMPLATE. CONTRACTOR SHALL DRILL ALL ANCHORING HOLES AND ASSIST OMEGA EQUIPMENT INSTALLERS WITH THRU BOLTING. CONTRACTOR IS RESPONSIBLE FOR FLOOR INTEGRITY AND BASE PLATE ANCHORING. CUSTOM FABRICATED CABINET. TYPE, STYLE AND COLOR DETERMINED BY OWNER. PROVIDE ONE 3" DIA. GROMMETED HOLE IN COUNTERTOP FOR CABLE ACCESS NEAR WHERE SHOWN. BRACE CABINET TO SUPPORT 300 POUNDS STATIC LOAD EVERY 48" SPAN. PROVIDE SLIDING SHELF FOR KEYBOARD AND MOUSE. PROVIDE NOTCH IN CABINET FOR A 10"d x 3.5"h WIRE TROUGH WHERE SHOWN IF APPLICABLE. REFER TO ELECTRICAL SHEETS FOR LOCATION OF WIRE TROUGH. CABINET DETAILS ARE PROVIDED FOR CONCEPTUAL PURPOSES ONLY - WORKING DRAWINGS BY OTHERS. MONITORS CAN BE MOUNTED ON COUNTERTOP OR ADJACENT WALL(S) IN ASUNDRIOUS ARAYS. GC SHALL CONSULT WITH FACILITY TO DETERMINE SPECIFIC MOUNTING SYSTEM(S). OPTIONAL MOUNTING BRACKETS FOR THE FLAT PANEL MONITOR(S) SHALL BE INSTALLED BY GENERAL CONTRACTOR. WALL BACKING OR OTHER MEANS OF STRUCTURAL SUPPORT IS STRONGLY RECOMMENDED WHEN INSTALLING WALL BRACKETS. GC SHALL CONSULT WITH FACILITY TO DETERMINE EXACT WALL LOCATION(S), IF ANY, FOR THE FLAT PANEL MONITORS AND TO DETERMINE SPECIFIC WALL MOUNTING SYSTEM(S) IF ANY. QTHE EQUIPMENT LOCATED IN THIS ROOM CREATES 5,550 BTU /HOUR. CUSTOMER /CONTRACTOR SHALL CONSIDER AN AIR CONDITIONING MEANS CAPABLE OF COOLING THE AREA WITH DOORS CLOSED. WORKING DRAWINGS BY OTHERS. EQUIPMENT CLOSET DESIGN: SMALL EQUIPMENT ROOMS HAVE INHERENT ISSUES THAT MUST BE ADDRESSED. THE FACILITY'S DESIGN TEAM SHALL REVIEW HVAC, COOLING, AIR FLOW IN A CONFINED SPACE; WEIGHT DISTRIBUTION, FLOOR LOADING; SERVICE CLEARANCE; INSTALLATION ACCESS, WORK FLOW AREAS; LIGHTING, SHADOWS, EMERGENCY LIGHTING; ELECTRICAL POWER, EMERGENCY POWER; STATIC ELECTRICITY; ACOUSTICS, SOUND NUISANCE; SEISMIC, VIBRATION, SHOCK. EACH EQUIPMENT CABINET HAS A MINIMUM AMOUNT OF SPACE AROUND IT THAT IS REQUIRED TO BE KEPT CLEAR SO THAT SERVICE MIGHT BE PERFORMED AND CABLES / METAL FLEX CONDUIT MAY BE CONNECTED AND DRAPED. EXACT CLEARANCE DIMENSIONS ARE DICTATED BY THE GREATER OF PREVAILING CODE OR THE MANUFACTURER'S SPECIFICATION. REFER TO EQUIPMENT DETAILS. SERVICE CLEARANCES MUST BE UNOBSTRUCTED AND MAINTAINED CLEAR. DO NOT ALLOW SERVICE CLEARANCE AREAS TO BE TEMPORARILY OR PERMANENTLY OCCUPIED. ALLOW ENOUGH ROOM AROUND CABINETS FOR NORMAL WORK FLOW MOVEMENT. CONSIDER THE PLACEMENT OF EQUIPMENT IN RELATION TO DOORS, WINDOWS, COLUMNS, AND WALL MOUNTED DEVICES, SUCH AS SURFACE MOUNTED WIRE TROUGH, CIRCUIT BREAKER PANELS, JUNCTION BOXES, ELECTRICAL OUTLETS, SAFETY EQUIPMENT, FIRE EXTINGUISHERS, AND FURNITURE. ALLOW EASY ACCESS TO ALL EMERGENCY POWER -OFF CONTROLS, CIRCUIT BREAKER PANELS, SMOKE DETECTORS, FIRE EXTINGUISHING SYSTEMS, ETC. RADIATION SHIELD/SURGICAL LIGHT MOUNTING PLATE. ALUMINUM MOUNTING PLATE WILL BE FURNISHED AND INSTALLED BY THE X-RAY EQUIPMENT INSTALLERS. REFER TO PLATE DETAIL. CONSULTING ENGINEERS SHALL ADJUST THE REFLECTED CEILING PLAN ACCORDINGLY. SUPPORT, ABOVE THE CEILING, DESIGNED BY OTHERS. QLOCATION OF TWO LONGITUDINAL RAILS AND CABLE TRACK FOR THE OMEGA OVERHEAD MONITOR BOOM. THE RAILS AND TRACK ARE ATTACHED TO THE BOTTOM OF UNISTRUT CHANNELS. THE RAILS AND TRACK ARE OVERLAYED ON THE UNISTRUT CHANNELS SO THE STRUCTURAL ENGINEER CAN CALCULATE PRIMARY LOADING POINTS. GENERAL CONTRACTOR SHALL DRILL TEN (10) 5/8" HOLES IN CONCRETE FOR THRU BOLT MOUNTING OF THE OMEGA C-ARM AND TABLE. NOTE: A FULL SIZE TEMPLATE, FOR LOCATING MOUNTING HOLES, IS AVAILABLE FROM OMEGA MEDICAL IMAGING 1-407-323-9400. MOUNTING HARDWARE TO BE CONTRACTOR FURNISHED - CONTRACTOR INSTALLED. 5" DIA. CABLE ACCESS HOLE FOR C-ARM Al L/C BASE PLATE 6 EA. 9/16" DIAMETER FASTENING HOLES (USE 1/2" - 13 UNC, GRADE 8 HARDWARE) ONE 5" DIA. CHASE NIPPLE TERMINATED FLUSH WITH FINISHED FLOOR. C CABLE ACCESS FOR C-ARM CABLES. 23.100" 600 0 37.00" 35.00" (4 M 0) 23.50" PLAN VIEW REVISED 01/27/2012 FOR CABLE ACCESS IN TABLE BASE 3.00" x 7.13" HOLE (MAX. TWO 2 1/2" CONDUITS INSIDE THIS AREA) LE COVER OUTLINE o TABLE BASE PLATE LO ti 16.50" 20.00" CENTER LINE 4 EA..63" DIAMETER FASTENING HOLES (USE 1/2" - 13 UNC, GRADE 8 HARDWARE) G.C. TO DRILL 5/8" CLEARANCE HOLES THRU CONCRETE. w J m u 0 z w O O. (REFER TO TABLE DETAIL PAGE) PLATE DETAIL) TWO 2-1/2" DIA. CHASE NIPPLES TERMINATED DT FLUSH WITH FINISHED FLOOR. ACCESS FOR TABLE CABLES. B .° d° e FLOOR ` d ° d d ° ° ° ° . ° e 3/8" THK x 3" SQUARE ---' STEEL PLATE (TYP. 10 PLACES) COVERPLATE MUST BE ACCESSIBLE 18" SECTION - —� COVERPLATE DOWN — CONNECTION MAY REQUIRE A FIELD MODIFICATION 38.0" 1/2" HEX HEAD BOLTS, GRADE 8 WITH LOCK AND FLAT WASHERS TYPICAL 10 PLACES TOTAL. (THRU BOLTING SHOWN) WIRE TROUGH COVERPLATES UP. COVERPLATES MUST BE ACCESSIBLE. 1011w x 3 1/2"d HOSPITAL GRADE WIRE TROUGH WITH TWO DIVIDERS AND COVERPLATES WIRE TROUGH COVERPLATES UP GENERAL CONTRACTOR SHALL DRILL 5/8" ANCHOR HOLES FOR THE OMEGA C-ARM AND TABLE BASE PLATES. WIRE TROUGH BELOW FLOOR - VIEWED FROM FOOT END OF TABLE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE FOLLOWING REQUISITES: CHASE NIPPLES SHALL BE GALVANIZED RMC. WIRE TROUGH SHALL BE 1011w x 3 1/2"d, HOSPITAL GRADE WITH TWO DIVIDERS AND ACCESSIBLE COVERPLATES. WIRE TROUGH LOCATED BENEATH THE FLOOR SHALL BE INSTALLED COVERPLATE UP WITH ONE EXCEPTION NOTED BELOW. END SECTION OF WIRE TROUGH, DIRECTLY BENEATH C-ARM, SHALL BE TURNED 1800 (COVERPLATE DOWN) SO THE 3/4'10 H.V. CABLE WITH A 1-5/8"O x 7-1/2" LONG CONNECTOR CAN BE PULLED THROUGH THE 5" O CHASE NIPPLE. FLIPPING 18" END SECTION OF WIRE TROUGH MAY REQUIRE FIELD MODIFICATIONS TO TROUGH AND COVER FOR ATTACHMENT. OPTIONAL TABLE BASE ANCHORING DETAIL (OPTIONAL ANCHORING WHEN THRU BOLTING IS NOT POSSIBLE) (MOUNTING HARDWARE TO BE CONTRACTOR FURNISHED -CONTRACTOR INSTALLED) CROSS SECTION VIEW FINISFILL. I LIIVL (TYPICAL) MOUNTING ROD 1/2-13 HEX NUT 1/2 LOCK WASHER 1/2 FLAT WASHER BASE PLATE FOOT END ►NAL GROUT FOR LEVELING BASE PLATE ADD THIS DIMENSION TO EMBEDMENT DIMENSION TO CALCULATE OVERALL ROD LENGTH RECOMMEND THE FOLLOWING ANCHORING SYSTEM BY HILTI (OR EQUIVALENT): HSE 2421 EPDXY ADHESIVE ANCHORING SYSTEM. 1/2" x 6 1/2" HAS SUPER ROD / ASTM A193 B7. DEPTH OF ROD EMBEDMENT: 4 1/2" MINIMUM CONCRETE DEPTH: 7" WITHIN 6" RADIUS OF EACH BOLT (CALCULATIONS BASED ON CONCRETE OF 2000PSI OR GREATER) HSE 2421 ALLOWABLE BOND/CONCRETE CAPACITIES: TENSION: 4055 LB. SHEAR: 4170 LB. (NOT TO SCALE) THE TWO REAR BOLTS (LOCATED AT FOOT END OF TABLE BASE PLATE) REQUIRES AN ANCHORING SYSTEM CAPABLE OF 39365 LB. TENSION PER BOLT. THE END USER OR THEIR CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THE ANCHORING SYSTEM IN COMBINATION WITH THE FLOOR MATERIAL AND FLOOR DEPTH WILL FACILITATE THIS REQUIREMENT. FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: NONE SHEET: A-5 ao N 24'-1 1 /2" T-8" PROPOSED OMEGA EQUIPMENT LAYOUT - AA (ROOM DIMENSIONS SWk,-L BE FIELD VERIFIED) (CONTRACTOR SHALL VERIFY LOCATION OF SUPPORT BEAMS AND JOISTS) (RECOMMENDED FINISHED CEILING HEIGHT: 9'-091 ) (DASHED LINES DEPICT EQUIPMENT TRAVEL / SWING; SERVICE CLEARANCES; DOOR SWINGS) EQUIPMENT CLOSET NOTES: EACH EQUIPMENT CABINET HAS A MINIMUM AMOUNT OF SPACE AROUND IT THAT IS REQUIRED TO BE KEPT CLEAR SO THAT SERVICE MIGHT BE PERFORMED AND CABLES / METAL FLEX CONDUIT MAY BE CONNECTED AND DRAPED. EXACT CLEARANCE DIMENSIONS ARE DICTATED BY THE GREATER OF PREVAILING CODE OR THE MANUFACTURER'S SPECIFICATION. REFER TO NEC 110.26, EQUIPMENT DETAILS AND CONSTRUCTION NOTE #6 ON SHEET A-4. THESE DRAWINGS ARE COPYRIGHTED. THEY ARE RESTRICTED TO THE SOLE USE OF GAMMA TECH, INC. THESE DRAWINGS ARE FOR CONCEPTUAL INTERPRETATION ONLY AND ARE NOT INTENDED FOR CONSTRUCTION. THESE DRAWINGS MAY NOT BE COPIED OR DISTRIBUTED TO ANY OTHER INDIVIDUAL(S) OR ORGANIZATION(S) WITHOUT A WRITTEN CONSENT BY GAMMA TECH, INC. OMEGA MEDICAL IMAGING, INC. HEATING, VENTILATING AND AIR CONDITIONING REQUIREMENTS OPERATING TEMPERATURE RANGE: 68' F (20' C) - 75' F (24' C). INTAKE AIR TO ALL EQUIPMENT SHALL BE MAINTAINED WITHIN THIS RANGE. RELATIVE HUMIDITY RANGE: 30% - 70% NON CONDENSING. REFER TO EQUIPMENT SCHEDULE FOR INDIVIDUAL EQUIPMENT BTU/HR RATING. FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: 1 /4" = 1 ' SHEET: B-1 EQUIPMENT SCHEDULE EQUIPMENT IDENTIFICATION NUMBER BTU / HOUR WEIGHT (LBS.) DESCRIPTION DIMENSIONS (IN.) NOTES 7-7 OMEGA MEDICAL IMAGING, INC. 1 50 OP 65CV CARDIOVASCULAR X-RAY CONTROL 12.21 16.54 3.70 9 OPERATOR CONSOLE (COUNTER MOUNTED) OMEGA MEDICAL IMAGING, INC. EQ CL 2 600 OP 65CV (65kw) CARDIOVASCULAR X-RAY GENERATOR 18.50 30.25 50.65 315 WITH CABLE DISCHARGE OPTION OMEGA MEDICAL IMAGING, INC. 3 350 8-200 23.00 62.50 84.25 850 AP EPS L/C POSITIONER (FLOOR MOUNTED) OMEGA MEDICAL IMAGING, INC. 4 100 C-400 TILTING /ELEVATING TABLE 27.00 94.00 41.00 625 WITH 94" TABLETOP OMEGA MEDICAL IMAGING, INC. EQ CL 5 1000 I-100 AP L/C AND TABLE ELECTRONICS RACK CABIN22-.00 25.50 76.00 377 (DIGITAL AP "GIM" IN CABINET) OMEGA MEDICAL IMAGING, INC. 6 150 DVD BURNER (NOT SHOWN) MOUNTED ON COUNTERTOP OMEGA MEDICAL IMAGING, INC. EQ CL 7 2000 IMAGING ELECTRONICS CABINET 23.62 32.00 25.50 130 CONTAINING THE PC, ISO TRANSFORMER AND UPS OMEGA MEDICAL IMAGING, INC. g 175 D-505 18" FLAT PANEL DISPLAY 17.00 9.90 18.40 24 (MOUNTED ON WALL OR COUNTERTOP) OMEGA MEDICAL IMAGING, INC. g 175 D-505 18" FLAT PANEL DISPLAY 17.00 9.90 18.40 24 (MOUNTED ON WALL OR COUNTERTOP) OMEGA MEDICAL IMAGING, INC. 10 N/A PC KEYBOARD AND MOUSE 19.00 8.00 3.00 4 (MOUNTED ON SLIDING SHELF) OMEGA MEDICAL IMAGING, INC. N/A D-613 - 2 OVER 2 CEILING SUSPENSION SYSTEM 160.00 60.00 68.50 255 (31" RADIUS PIVOT ARM) (MAX WEIGHT CAPACITY = 200LBS) 100 D-550 18.1" FLAT PANEL IMAGE DISPLAY 17.00 3.00 13.90 24 100 D-550 18.1" FLAT PANEL IMAGE DISPLAY 17.00 3.00 13.90 24 (MOUNTED ON OMEGA CEILING SUSPENSION SYSTEM) MAVIG rl 2 150 Z-513 SURGICAL LIGHT AND RADIATION SHIELD R61" MAX. SWING 68.00 243 (CEILING MOUNTED) Z-705 TEAL ELECTRONICS CORPORATION EQ CL 13 1950 MODEL PCDU-ORF 21.68 20.50 58.33 550 (POWER CONDITIONER /ISOLATION TRANSFORMER) NOTE EXPLANATION: CU UL: LUU/A 1 CU IIV 1 1'1C 1=1,1U1r'IVICIV 1 ULUJC 1. Faciurv: Florida Hospital Zephyrhills, FL DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: 1 /4" = 1 ' SHEET: _ I I I II Ilu I I I! I u INDICATES CENTER OF GRAVITY �n N d• 00 8'-6 11 /16" PLAN VIEW OVERHEAD VIEW - ROTATIONAL C-ARM OPERATING ENVELOPE SIDE VIEW SIDE VIEW - CRANIAL/CAUDAL C-ARM OPERATING ENVELOPE LENGTH = 62.5" WIDTH = 23.0" HEIGHT = 84.25" ) LBS. �NGE RAN r=3�r- OMEGA MEDICAL IMAGING B-200 L/C POSITIONER THE DETAIL DRAWINGS ARE TO AID THE GENERAL CONTRACTOR WHO IS RE��EPS�ORFOF GRAVITY SUPPORTS FOR THE UNIT THEY WILL ALSO ALLOW THE ELECTRICAL CONTRACTOR TO LOCATE THE CABLE ACCESS. ( NOT TO SCALE) J FRONT VIEW 3'-10" 3'-10" FRONT VIEW - RAO/LAO C-ARM OPERATING ENVELOPE FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: N.T.S. SHEET: D=1 (NOT TO SCALE) 3'-2" FOOT END PLAN VIEW TABLE AND L/C ARM FINISHED CEILING FINISHED CEILING POSITIONER. 2 2 w w = 2 B-200 L/C POSITIONER z z J_ J_ IIIw C-400 TILTING / U 0 ELEVATING TABLE w w � 0 z z w w + 0w 0 0 CDz 0 M� o 0 � i� FLOOR FLOOR FRONT VIEW SIDE VIEW OMEGA MEDICAL IMAGING C-400 ELEVATING CARDIAC TABLE WITH 104" TABLE TOP CARBON FIBER TABLE TOP LENGTH = 94" WIDTH = 27" TABLE WEIGHT = 625 LBS. (WITHOUT PATIENT) TABLE TILT RANGE: 800 UPRIGHT 150 TRENDELENBURG TABLE ELEVATION RANGE: 33" TO 43" HEAT OUTPUT = 100 BTU/HR. (INTERMITTENT USE) MAX. PATIENT LOAD = 350 LBS. RECOMMENDED CEILING HEIGHT: SINGLE PLANE = 9'-0" DUAL PLANE = 9'-6" INDICATES CENTER OF GRAVITY WORST CASE SCENARIO PATIENT WEIGHT: 350 LBS. PATIENT HEIGHT: 6'-6" 27.00" 19.00if END VIEW Z 0 Q J w J Q M M eM 1 R n" 94.0" 18.0" PLAN VIEW :1 21.00" FRONT VIEW OMEGA MEDICAL IMAGING C-400 ELEVATING TABLE WITH 94" TABLE TOP u'i z 0 H Q J J U)w z Cn w >- z W w J Z aQ J J w Of O O LL Z 0 U) w ir 0�0 :D w wU' 0 C� LLJ w � o Z ' J_ w U co THE DETAIL DRAWINGS ARE TO AID THE GENERAL CONTRACTOR WHO IS REQUIRED TO PROVIDE SUPPORTS FOR THE UNITS SHOWN. THEY WILL ALSO ALLOW THE ELECTRICAL CONTRACTOR TO LOCATE THE CABLE ACCESS. ( NOT TO SCALE ) SIDE VIEW FINISHED CEILING (NOT TO SCALE) in N O co 1-100 CABINET 1-100 CABINET LENGTH 25.5" 25.5" WIDTH 22.0" 22.0" HEIGHT 84.511" 84.5"" WEIGHT 377 LBS. 210 LBS. HEAT OUTPUT 1000 BTU/HR. 1000 BTU/I 1-100 CABINET REQUIRED FOR SINGLE PLANE. 1-100 AND 1-100 CABINET REQUIRED FOR DUAL I LO 6 N O 6 N INDICATES CENTER OF GRAVITY O N c'M PLAN VIEW 22.0" CIO FRONT VIEW SIDE VIEW 1-100 AP L/C AND TABLE ELECTRONICS CABINET xv 1-100 LAT L/C AND INTERFACE BI-PLANE RACK CABINET X-RAY GENERATOR POWER SUPPLY (CV - CARDIOVASCULAR) OP50CV, OP65CV, OP80CV, OP90CV AND OP100CV DEPTH = 30.25" WIDTH = 18.50" HEIGHT = 50.65" WEIGHT = 315 LBS. HEAT OUTPUT = 600 BTU/HR. 18.50" PLAN VIEW FRONT VIEW FACILITY: Florida Hospita Zephyrhills, FL 30.25" SIDE VIEW Service Clearance: 30" Wide x 36" Deep, Front and Back. Refer to NEC 110.26. OPERATORS CONSOLE DEPTH = 10.88" WIDTH = 13.25" WEIGHT = 8 LBS. 13.13" 3' III PLAN VIEW SIDE VIEW mm DATE: 01.30.2012 FILE NAME: FHZ122011 Service Clearance: 30" Wide x 36" Deep, Front and Back. Refer to NEC 110.26. SCALE: N.T.S SHEET: D = 2 I � _ _ I II I !' I ' I III 1. I 1 I __ I _ I I I _� � I -. r, 21.68" (55.07CM) ACCOMODATE"I 3/8" BOLT (TYP) OUTPUT CIRCUIT BREAKEF (CB2-CB7 71M-71 VIEW SEISMIC ANCHORING LOCATIONS (3 PLCS EACH SIDE.) N CM O � CO GENERATOR CIRCUIT BREAKER (CB1) OPTIONAL TEAL MODEL #PCDU-ORF, 240 KVA (MAX. RATING) POWER CONDITIONER DIMENSION DIAGRAM (NOT TO SCALE) 10.84" 6" (27.53CM) (1 f; 9ArMl MODEL NUMBER PCDU-ORF KNOCKOUT INPUT VOLTAGE 440/460/480/500V 60Hz 3-PHASE DELTA/WE :S) OUTPUTS GENERATOR: 480/277V 3-PHASE WYE 60Hz IMPEDANCE <0.06 OHMS L-L, LOAD REGULATION 3% k. THRU HOLE ',S) BREAKERS GENERATOR 90A 3-POLE 480V (ELECTROMED GENERATOR) ,. 1-100 CABINET 30A 2-POLE 208V (RACK CABINET) H.S.S. / CONTROL 30A 2-POLE 208V (HIGH SPEED STARTER AND CONTROL VOLTAGE) ` c g DIGITAL 20A 1-POLE 120V (RACK CABINET) � SUPPRESSORS U MONITOR STRIP 20A 1-POLE 120V IMAGING CABINET � PRINTER 15A 1-POLE 120V (OPTIONAL PRINTER) c) c SURGICAL LIGHT 15A 1-POLE 120V (OPTIONAL SURGICAL LIGHT) WORKSTATION 15A 1-POLE 120V (OPTIONAL REMOTE WORKSTATION) ALTERNATE SEISMIC WHEN SHIPPING/MOUNTING GROUNDING: ISOLATABLE GROUND BUSBAR SYSTEM FOR ALL OUTPUT GROUNDS PLUS CONNECTION o ANCHORING SHIPPING BRACKET BRACKET OF LOCAL GROUNDING ELECTRODE PER NEC REMOVED (TYP) CONTROLS: INCLUDES 115V SHUNT -TRIP CONTROL WITH CONTACTS FOR EXTERNAL EPO PUSH-BUTTON 0 0 0 AUDIBLE: LESS THAN 50DB (A) AUDIBLE NOISE MEASURED AT 1 METER u RL uRL APPROVALS: UL LISTED TO STANDARD 1012/187 FOR POWER SUPPLIES AND X-RAY FRONT VIEW FRONT VIEW (SHOWN WITH DOOR REMOVED) SIDE VIEW TEAL SPECIFICATIONS FOR SYSTEM QUOTED INPUT: 480VAC, DELTA, THREE PHASE, 60Hz, 100 kVA. OUTPUT: VOLTAGE PHASE CIRCUIT BREAKER SIZE POLE kVA EQUIPMENT 480Y THREE 90 (SHUNT TRIP) 3P 105 X-RAY GENERATOR 208 SINGLE 30 2P 5 RACK CABINET 120 SINGLE 20 1P 2 RACK CABINET 120 SINGLE 20 1P 2 IMAGING CABINET 120 SINGLE 15 1P 1.44 SURGICAL LIGHT (VIA RACK CABINET) TOTAL: 115.44 FACILITY: Florida Hospital Zephyrhills, FL Service Clearance: 30" Wide x 36" Deep, Front and Back. Refer to NEC 110.26. DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: N.T.S SHEET: D-4 I . e CV Cn SPECIAL NOTE TO ELECTRICAL CONTRACTOR THIS PLAN DID NOT INCLUDE COMMON OPTIONS SUCH AS: - POWER AND CABLE RUNS FOR THE ELECTROPHYSIOLOGY PATIENT MONITORING SYSTEM. - CONVENIENCE OUTLETS AT TABLE BASE. - POWER, CABLE RUNS AND CONDUITS FOR A REMOTELY LOCATED LASER IMAGER OR PRINTER. THE EC SHALL BE REQUIRED TO CONSULT WITH THE CUSTOMER REGARDING ADDITIONAL DEVICES NOT COVERED IN THE SCOPE OF THIS WORK. THE EC SHALL BE RESPONSIBLE FOR INSTALLATION OF ADDITIONAL SUPPORTS TO FACILITATE THE CUSTOMERS OPTIONS. FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: 1 /4" = 1 ' SHEET: E=1 1 u i i I I i L - - I 1 L [I --- TERMINAL SCHEDULE ( CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) ITEM DESCRIPTION FACILITY TO DETERMINE 112.5KVA, 480VAC, 3-PHASE, POWER SOURCE LOCATION FOR TEAL POWER CONDITIONER. NEMA 1, 480VAC, THREE PHASE, 5-WIRE, FRONT OPERATED, CIRCUIT BREAKER ENCLOSURE WITH GROUND ACCESSORIES. A ENCLOSURE SHALL CONTAIN ONE 100AMP, 3-POLE, THERMAL MAGNETIC CIRCUIT BREAKER WITH SHUNT TRIP DEVICE. FLUSH MOUNT IN WALL WHERE SHOWN. LOCATE TOP OF ENCLOSURE 6-0" A.F.F. NOTE: EC SHALL ENSURE THAT LUGS ARE LARGE ENOUGH TO FACILITATE OVERSIZED INCOMING CABLES REQUIRED BY X-RAY EQUIPMENT. REFER TO "INCOMING WIRE SIZE" NOTES. B 4" x 2" SWITCH BOX. PROVIDE N.O./N.C. SWITCH WITH RED MUSHROOM HEAD AND AN "EMERGENCY OFF" NAME PLATE. FLUSH MOUNT IN WALL WHERE SHOWN. LOCATE BOX CENTER LINE 6-0" A.F.F. EXACT NUMBER AND LOCATION TO BE DETERMINED BY CUSTOMER. INSTALL ONLY IF REQUIRED BY PREVAILING CODE OR IF REQUESTED BY CUSTOMER 8" x 3" WIDE GROMMETED CABLE ACCESS HOLE IN BOTTOM OF WIRE TROUGH. LOCATE BOTTOM OF TROUGH 20" A.F.F. D CABLE ACCESS FOR THE IMAGING CABINET. REFER TO DETAIL ON SHEET E-6. ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. 8" x 3" WIDE GROMMETED CABLE ACCESS HOLE ON TOP OF WIRE TROUGH. LOCATE TOP OF TROUGH 24" A.F.F. REFER TO CDETAIL ON SHEET E-6. CABLE ACCESS FOR THE FLAT PANEL MONITOR(S), MOUSE / KEYBOARD; X-RAY CONTROL CONSOLE; OPTIONAL DVD BURNER. ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. 8" x 3" WIDE GROMMETED CABLE ACCESS HOLE IN BOTTOM OF WIRE TROUGH. LOCATE BOTTOM OF TROUGH 20" A.F.F. ECABLE ACCESS FOR THE X-RAY POWER SUPPLY CABINET. REFER TO DETAIL ON SHEET E-6. ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. 12" x 12" x 4" DEEP JUNCTION BOX. SURFACE MOUNT ON WALL WHERE SHOWN. LOCATE BOTTOM OF JUNCTION BOX 2'-8" A.F.F. E 1 CONNECTION BOX FOR 480VAC, THREE PHASE POWER TO TEAL POWER CONDITIONER. EC SHALL PROVIDE ONE 1 1/2 O SEALTITE AND ASSOCIATED CONNECTORS BETWEEN TEAL UNIT AND BOX E1. OPEN END OF 5" O CHASE NIPPLE TERMINATED FLUSH WITH FINISHED FLOOR WHERE SHOWN. GCABLE ACCESS FOR THE FLOOR MOUNTED POSITIONER. CHASE NIPPLE CONNECTED TO WIRE TROUGH LOCATED BELOW THE FINISHED FLOOR. 8" x 3" WIDE GROMMETED CABLE ACCESS HOLE IN BOTTOM OF WIRE TROUGH. LOCATE BOTTOM OF TROUGH 20" A.F.F. JCABLE ACCESS FOR THE ELECTRONICS RACK CABINET. REFER TO DETAIL ON SHEET E-6. ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. 12" x 12" x 8" DEEP JUNCTION BOX. FLUSH MOUNT IN CEILING WHERE SHOWN. mPROVIDE ONE 2 1/2"0 CHASE NIPPLE / BUSHING CENTERED IN OVERSIZED REMOVABLE SPLIT COVERPLATE. CABLE ACCESS FOR CEILING SUSPENDED MONITORS. REFER TO COVERPLATE DETAILS. OPTIONAL DOOR ACTIVATED SWITCH. SQUARE-D CAT - CLASS 9007 TYPE AO (OR EQUAL). N(TO BE INSTALLED ONLY IF REQUIRED BY PREVAILING CODE OR IF REQUESTED BY CUSTOMER). SWITCH SHALL BE LOCATED ON HINGE SIDE OF DOOR. OPEN ENDS OF TWO 2-1/2" DIA. CHASE NIPPLES TERMINATED FLUSH WITH FINISHED FLOOR WHERE SHOWN. T CABLE ACCESS FOR THE PATIENT TABLE. CHASE NIPPLES CONNECTED TO WIRE TROUGH LOCATED BELOW THE FINISHED FLOOR. 4" x 4" x 2" DEEP JUNCTION BOX FOR THE "X-RAY IN USE" WARNING SIGN. EXACT LOCATION TO BE DETERMINED BY wOTHERS. FLUSH MOUNT IN WALL OR CEILING. REQUIRES HOUSE POWER. INSTALL. ONLY IF REQUIRED BY PREVAILING CODE OR IF REQUESTED BY CUSTOMER JUNCTION BOX LOCATE ABOVE THE FINISHED CEILING WHERE SHOWN. SIZE DEPENDENT ON MODEL OF SURGICAL LIGHT z ORDERED. VERIFY SIZE WITH INSTALLERS. PROVIDE COVERPLATE WITH 6'4" LONG, 1/2" DIA. GREENFIELD. CABLE ACCESS FOR SURGICAL LIGHT POWER. MINIMUM 18" LONG COPPER GROUND BUS BAR. CONSULT WITH EQUIPMENT REPRESENTATIVE REGARDING EXACT SIZE AND M G B LOCATION. PROVIDE DRILLED AND TAPPED HOLES FOR GROUND WIRE ATTACHMENT. REFER TO BLOCK DIAGRAMS. NOTE: REFERENCE TO "SEALTITE" BRAND MEANS REDUNDANT GROUND, PVC COATED, FLEXIBLE METAL CONDUIT. NOTE: THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR DIVIDING ALL JUNCTION BOXES AND CONNECTING TROUGHS TO MEET LOCAL AND FLORIDA AHCA REQUIREMENTS. COVERPLATE DETAILS ALL FLUSH MOUNTED DEVICES SHALL HAVE OVERSIZED COVERPLATES. REMOVABLE SPLIT COVERPLATE 2 1/2" 0 CHASE NIPPLE / BUSHING 14" L 12" (E1, M) COVERPLATE FACILITY: Florida Hospital Zephyrhills, FL (NOT TO SCALE) -WRAWN BY: Dave Mosei DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: 1 /4" = 1' SHEET: IMPORTANT POWER NOTES WIRING NOTES INCOMING WIRE SIZE NOTES ( CONTRACTOR FURNISHED -CONTRACTOR INSTALLED) ( CONTRACTOR FURNISHED -CONTRACTOR INSTALLED) 1. POWER LINES FOR EQUIPMENT LISTED SHALL BE DEDICATED LINES RUN DIRECTLY FROM NEAREST FACILITY POWER SOURCE. UNDER NO CIRCUMSTANCES SHALL ANY OTHER ELECTRICAL EQUIPMENT BE CONNECTED TO THESE POWER LINES NOW OR IN THE FUTURE. LINE REQUIREMENTS A. NO TRANSIENTS (IMPULSES FROM 0.5 TO 800 MICROSECONDS) THAT EXCEED 30F NOMINAL PEAK LINE VOLTAGE, AS MEASURED BY A POWER LINE ANALYZER, WITH THE SYSTEM IN STANDBY SHALL OCCUR. B. TRANSIENTS EQUAL TO OR GREATER THAN 30F NOMINAL PEAK LINE VOLTAGE. - SHALL NOT OCCUR MORE THAN ONCE PER HOUR. - SHALL NOT EXCEED MORE THAN 12 IMPULSES PER 24-HOUR PERIOD. 2. IF ANY OF THE ABOVE POWER SPECIFICATIONS REGARDING LINE TRANSIENTS OR NOMINAL LINE VOLTAGE, CANNOT BE MET, THE FOLLOWING CORRECTIVE ACTION MUST BE TAKEN: CONTACT TOM FISHLER, P.E. 262-827-9101 TEAL MEDICAL CORP. TO ORDER AN EQUIPMENT SPECIFIC TEAL UNIT. WHEN PLACING ORDERS: REFERENCE FILE NAME LOCATED IN BOTTOM RIGHT OF SHEET A-1. VOLTAGE REGULATION WITH OPTIONAL TEAL UNIT A. 112.5KVA, THREE PHASE, 480VAC INCOMING LINE TO MAIN DISCONNECT WITH 5% VOLTAGE REGULATION UNDER INTERMITTENT NO LOAD TO FULL LOAD CONDITIONS REQUIRED. 60HZ ±0.5%. 3. IF ANY OF THE ABOVE POWER SPECIFICATIONS REGARDING VOLTAGE REGULATION, CANNOT BE MET, THE FOLLOWING CORRECTIVE ACTION MUST BE TAKEN: A REGULATION TRANSFORMER OR LINE CONDITIONER DEPENDING ON THE SEVERITY OF THE PROBLEM SHALL BE EMPLOYED TO MAINTAIN LINE VOLTAGE WITHIN 5F NOMINAL UNDER INTERMITTENT, NO LOAD TO FULL LOAD CONDITIONS. TEAL POWER CONDITIONER NOTE NOTE: IF A LINE MATCHING TRANSFORMER IS REQUIRED, OR IF THE FACILITY IS EXPERIENCING GROUNDING OR POWER CONDITION PROBLEMS, OMEGA MEDICAL RECOMMENDS THE PURCHASE OF A TEAL UNIT INSTEAD OF A LINE MATCHING TRANSFORMER. THE TEAL UNIT REPLACES THE 1) LINE MATCHING TRANSFORMER; 2) MAIN DISCONNECT (A); 3) LOAD CENTER (Al); AND 4) TRANSIENT CONTROL WHICH WILL PROTECT THE EQUIPMENT FROM VOLTAGE SPIKES, ETC. A TEAL UNIT WILL SAVE CONSTRUCTION TIME AND REDUCE CONSTRUCTION COST. CONTACT TOM FISHLER 262-827-9101. ORDER MODEL #PCDU-ORF PER GENERATOR. YOU MUST SPECIFY PRIMARY VOLTAGE: 208 OR 480VAC THREE PHASE INPUT. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS, WIRE, WIREWAYS, DISTRIBUTION TRANSFORMERS, JUNCTION BOXES, ENCLOSURES, CIRCUIT BREAKERS, ETC. ALL WIRES TO BE THHN TYPE, STRANDED COPPER UNLESS OTHERWISE SPECIFIED. THE ELECTRICAL CONTRACTOR SHALL SUPPLY LUG PAIRS OF #8 OR GREATER FOR ALL CABLES LISTED WITHIN THE SCOPE OF THIS WORK. CONDUIT AND DUCT RUNS ARE SHOWN SCHEMATICALLY. ACTUAL BUILDING CONDITIONS WILL DETERMINE CONDUIT AND DUCT ROUTES. CONDUIT TURNS TO HAVE LARGE SWEEPING BENDS WITH MINIMUM RADIUS AS SPECIFIED IN NEC ART. 346-10. IF LARGE BENDS IN CONDUIT ARE NOT POSSIBLE, USE SERVICE ENTRANCE ELBOW CONNECTORS TO AVOID DAMAGE TO CABLE. ELECTRICAL CONTRACTOR TO PROVIDE 10'-0" TAILS FOR ALL WIRES UNLESS OTHERWISE SPECIFIED AND IDENTIFY BOTH ENDS OF ALL WIRES. ELECTRICAL CONTRACTOR SHALL MAKE EVERY EFFORT TO ENSURE THAT POINT TO POINT CONDUIT RUNS ARE AS SHORT AS FIELD CONDITIONS ALLOW. LEAVE PULL WIRE IN EMPTY CONDUITS. WORK SHALL COMPLY WITH REGULATORY AGENCIES OF JURISDICTION. ALL SUCH AGENCIES SUPERSEDE THESE DRAWINGS AND MUST BE ADHERED TO. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCRUTINIZING THESE DRAWINGS AND SHALL MAKE CORRECTIONS ACCORDING TO PREVAILING CODES. NOTE: CONDUITS MAY BE INCREASED IN SIZE BUT NEVER DECREASED WITHOUT CONSENT FROM THE EQUIPMENT REPRESENTATIVES. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR 11,.STALLING THE PATIENT GROUNDING NETWORK PER NATIONAL ELECTRIC CODE ARTICLE 517 AND NFPA 70. ALL CONDUIT SHALL BE RIGID TYPE UNLESS SPECIFIED OTHERWISE IN THIS DRAWING SET. ALL CONDUIT RUNS EXPOSED TO WET ENVIRONMENTS SHALL BE MADE LIQUID TIGHT. (e.g. UNDERGROUND, ETC.) ALL FLUSH MOUNTED ELECTRICAL BOXES AND WIRE TROUGHS SHALL HAVE OVERSIZED COVER PLATES. ALL FLUSH MOUNTED ELECTRICAL BOXES AND WIRE TROUGHS EXPOSED TO A WET ENVIRONMENT SHALL BE MADE LIQUID TIGHT. (e.g. IN FLOOR, ETC.) THE ELECTRICAL CONTRACTOR SHALL INSTALL, PROVIDE POWER TO AND CONNECT THE FOLLOWING IF REQUIRED: THE "X-RAY IN USE" WARNING SIGN; THE 120VAC, 15AMP RECEPTACLE AND BNC CONNECTORS; THE DOOR INTERLOCK SWITCH; THE EMERGENCY OFF SWITCH; AND THE 120VAC, DUPLEX OUTLETS FOR SERVICE AND HOUSEKEEPING DESCRIBED IN THE GENERAL NOTES ITEM #6. SPECIAL NOTE TO ALL ANCILLARY EQUIPMENT SUPPLIERS: THE ELECTRICAL SPECIFICATIONS IN THESE PLANS ARE DEDICATED TO THE EQUIPMENT PROVIDED BY OMEGA MEDICAL IMAGING. ALL ADDITIONAL EQUIPMENT SUPPLIERS SHALL NOT USE ANY ELECTRICAL DEVICES CALLED OUT IN THESE PLANS AS A PART OF THEIR ELECTRICAL REQUIREMENTS OR SCHEMATIC. ALL ADDITIONAL EQUIPMENT SUPPLIERS SHALL ISSUE A SEPARATE DETAILED SPECIFICATIONS PACKAGE TO THE ARCHITECT OR TO THE CUSTOMER. THE ARCHITECT SHALL EXTRAPOLATE THIS INFORMATION AND INCORPORATE IT INTO THEIR WORKING DRAWINGS. OMEGA MEDICAL IMAGING IS NOT RESPONSIBLE FOR FURNISHING INFORMATION ON EQUIPMENT THEY DO NOT PROVIDE. ADDITIONAL EQUIPMENT, OTHER THAN O.M.I., DEPICTED IN THESE PLANS HAVE BEEN SHOWN AS A COURTESY TO OUR CUSTOMERS. LISTED BELOW IS THE RELATIONSHIP BETWEEN THE LENGTH AND SIZE OF EACH INCOMING WIRE, WITH THE ASSUMPTION THAT THE POWER SOURCE HAS THE REQUIRED CAPACITY. THE VOLTAGE REGULATION UNDER LOAD VARIATION IS CALCULATED TO BE WITHIN ±5%. BE SURE TO USE WIRE SIZES INDICATED. RECOMMENDED POWER TO THE MAIN DISCONNECT: MAIN CIRCUIT BREAKER: X-RAY GENERATOR: MAXIMUM MOMENTARY: Long Term: MAXIMUM LINE IMPEDANCE: 480VAC, THREE PHASE, 75KVA, 60Hz, WYE-5WIRE 60AMP, 3-POLE, THERMOMAGNETIC EMD TECHNOLOGIES EPSILON 65KW - EPS 65 R/F 105 AMPS / 67KVA 7AMPS/ 4.1 KVA 0.16 OHMS * PROVIDE THE APPROPRIATE WIRE SIZE FROM POWER SOURCE TO MAIN DISCONNECT: WIRE LENGTH LESS THAN 50' 100, 200' ** GREATER THAN 200' FEEDER SIZE LINE: #3AWG #3AWG #1/OAWG #2/OAWG NEUTRAL: #3AWG #3AWG #1/0AWG #2/OAWG GROUND: #8AWG #8AWG #6AWG #4AWG * VOLTAGE DROP CALCULATED FOR LESS THAN 1 %. ** WIRE SIZE CALCULATED AT 300 FEET. IF RUN IS LONGER THAN 300', EC SHALL NOTIFY EQUIPMENT INSTALLER. PATIENT SAFETY GROUNDING CONSIDERATIONS: A SPECIAL GROUNDING SYSTEM IS REQUIRED IN ALL DIAGNOSTIC ROOMS BY SOME STATE AND LOCAL CODES. THIS GROUNDING SYSTEM IS STRONGLY RECOMMENDED IN AREAS WHERE ELECTRICALLY SUSCEPTIBLE PATIENTS MIGHT BE EXAMINED OR TREATED UNDER PRESENT, FUTURE OR EMERGENCY CONDITIONS. CONSULT WITH THE GOVERNING ELECTRICAL CODES AND CONFER WITH APPROPRIATE HOSPITAL ADMINISTRATIVE PERSONNEL AND CONSULTING ENGINEERS TO DETERMINE THE AREAS REQUIRING THIS GROUNDING SYSTEM. IF SUCH A GROUNDING SYSTEM IS REQUIRED, THE RESPONSIBLE CONSTRUCTION PARTICIPANTS SHALL DESIGN AND INSTALL GROUNDING SYSTEM TO INCLUDE ALL METAL OBJECTS AND FIXTURES. FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: NONE SHEET: E=3 I I 1 1 I 1 I 1 1I 1 111_' _ 1 n 1 it — ! — I— ''I I I. I ! I ESb I ELECTRICAL TAG IDENTIFICATION ( CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) 10" x 3 1/2" DEEP SURFACE MOUNTED VERTICAL RISER. CONNECT TO HORIZONTAL WIRE TROUGH 1 AND WIRE TROUGH LOCATED BELOW THE FLOOR (USE 45° SECTION) AND TERMINATE CAPPED END ABOVE THE FINISHED CEILING FOR CONDUIT CONNECTIONS. REFER TO TROUGH NOTES AND ELEVATIONS. 10" X 3 1/2" DEEP WIRE TROUGH LOCATED BELOW THE FLOOR. CONNECT TO VERTICAL RISERS 2 WHERE SHOWN. INSTALL WITH COVERPLATE UP EXCEPT 18" SECTION DIRECTLY BENEATH C-ARM CONDUIT (G) WHICH HAS COVERPLATE DOWN. REFER TO TROUGH NOTES, ELEVATIONS AND DETAIL ON SHEET A-5. 10" x 3 1/2" DEEP SURFACE MOUNTED VERTICAL RISER. CONNECT TO HORIZONTAL WIRE TROUGH 3 AND WIRE TROUGH LOCATED BELOW THE FLOOR (USE 45° SECTION). REFER TO TROUGH NOTES AND ELEVATIONS. 10" x 3 1/2" DEEP SURFACE MOUNTED HORIZONTAL WIRE TROUGH. 4 CONNECT TO VERTICAL RISER AND TERMINATE WHERE SHOWN. REFER TO TROUGH NOTES AND ELEVATIONS. EC SHALL PROVIDE ONE 120VAC, 15AMP DUPLEX RECEPTACLE. FLUSH MOUNT IN WALL NEAR SHOWN. 5O PROVIDES POWER FOR SERVICE AND HOUSEKEEPING. (REQUIRES HOUSE POWER). DIMENSIONS ARE NOT CRITICAL. M PROVIDE VPN ACCESS TO THE INTERNET OR A SINGLE MODEM TELEPHONE LINE IN THE WALL FOR SERVICEABILITY PURPOSES. THE RJ11 LINE MUST BE A DEDICATED DIRECT IN DIAL (DID) VOICE -GRADE TELEPHONE LINE WITH ACCESS LOCATED NEAR DIGITAL PC ELECTRONICS CABINET. DO NOT CONNECT TO FACILITY PBX SYSTEM. FLUSH MOUNT IN WALL. REFER TO ELEVATIONS. E PROVIDE ETHERNET CONNECTION. EC SHALL CONSULT WITH END USER REGARDING TYPE OF CONNECTOR (e.g.. RJ-45/CAT-5, FIBER OPTICS, BNC/COAX, ETC.). REFER TO DICOM NOTES. PROVIDE ALL HARDWARE NECESSARY INCLUDING COVER PLATES, CONNECTORS AND INTERCONNECTING CABLES. FLUSH MOUNT IN WALL. REFER TO ELEVATIONS. DICOM, PACS, LANS/WANS, Ethernet, Modems Networking Notes: Supplying and installing network connections between diagnostic imaging equipment and other node connections shall be the customer's responsibility. Customer must specify, supply and install proper receptacles, AUI transceivers, cabling, repeaters, routers, modems, etc. which are consistent with the site needs and sound network implementation practices. Also included, but not limited to, the customer's responsibility is the purchase and installation of conduits and / or raceways for containment and routing of networking cables, as determined by site conditions or required by prevailing codes. Florida Hospital Zephyrhills, FL DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: 1 /411 = 1 ' SHEET: E=4 1-i VMS 00 A o 00 b N 5 1 4 J D E1 MGB E b (D5 b 5 1 U2 FINISHED CEILING LINE (TYPICAL). FINISHED FLOOR LINE (TYPICAL). B 4 17 1EM Mn e e d d FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: SCALE: Dave Moser 1 /4" = 1' DATE: SHEET: 01.30.2012 FILE NAME: FHZ122011 GENERAL NOTES: - LONG SIDE OF GROMMETED OPENING SHOULD BE PERPENDICULAR TO TROUGH RUN - FOR EXACT SIZE OF COVERS AND OPENINGS, SEE "JUNCTION BOX AND COVER PLATE DESCRIPTIONS." - CONTRACTOR SHALL SPLIT COVERS, CUT OPENINGS AND PROVIDE GROMMETS AS INDICATED OR PURCHASE THESE ITEMS FROM SUPPLIER. GROMMETED OPENING AT TOP (OR BOTTOM) OF TROUGH OR RACEWAY TUB GROMMETED OPEN END OF TROUGH OR RACEWAY TROUGH/RACEWA Y CO VER PLA TE & OPENING DETAIL S (NOT TO SCALE) TYPICAL WALL TROUGH OPENINGS 8" x 3" GROMMETED OPENING LOCATED ON TOP FACE OF WALL TROUGH AND GROMMETED 8" x 3" PARTITION CUTOUTS LOCATED BELOW THE OPENING. 8" x 3" GROMMETED OPENING LOCATED ON THE FACE OF THE HORIZONTAL OR VERTICAL WALL TROUGH 8" x 3" GROMMETED OPENING LOCATED ON BOTTOM FACE OF WALL TROUGH AND GROMMETED 8" x 3" PARTITION CUTOUTS LOCATED ABOVE THE OPENING. SURFACE OR FLUSH MOUNTED WALL TROUGH WITH THREE DIVIDED PARTITIONS THROUGHOUT WITH PARTITION CUTOUTS AT OPENINGS. GROMMETED OPENING AT SIDE OF TROUGH OR RACEWAY TUB FL USH JUNCTION BOX & CONDUI T ADAPTION TO SURFACE MOUNTED RACEWA Y/TROUGH JUNCTION BOX AND - CONDUIT WITHIN WALL (NOT TO SCALE) WALL LINE COVER PLATE COVER PLATE CUTAWAY VIEW GROMMET SHARP EGDES SURFACE RACEWAY/TROUGH TUB OPENING THROUGH REAR OF RACEWAY/ TROUGH TUB TO MATCH JUNCTION BOX OPENING GENERAL NOTES: - THIS DETAIL IS A RECOMMENDATION ONLY. CONTRACTOR TO DETERMINE ACTUAL METHODS BASED ON SPECIFIC SITE CONDITIONS. TROUGH NOTES ( CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) 1) ALL WIRING TROUGH (WALL DUCT & TRENCH DUCT) PRODUCTS TO BE TYPES "RWT" AND "RSV" AS MANUFACTURED BY SQUARE-D / SCHNEIDER ELECTRIC CO. 2) SITE SPECIFIC SIZES ARE NOTED IN THIS DRAWING SET. FOR YOUR CONVENIENCE IN ORDERING, COPIES OF THE ELECTRICAL SHEETS (FOR THIS PROJECT) HAVE BEEN E-MAILED TO SQUARE-D WIRE MANAGEMENT SYSTEMS, FOR AN ACCURATE TAKEOFF OF THE DUCT. 3) FOR PRE -ESTABLISHED DEEP DISCOUNTED PRICING ON THE TROUGHS, CONTACT YOUR LOCAL AUTHORIZED SQUARE D DISTRIBUTOR OR SQUARE D SALES REPRESENTATIVE AND REFER TO THE FILE NAME (LOCATED AT THE BOTTOM RIGHT HAND CORNER OF THIS DRAWING); PROJECT NAME AND LOCATION. 4) FOR PRODUCT INFORMATION AND/OR THE SQUARE D OFFICE OR DISTRIBUTOR NEAREST YOU, PLEASE VISIT THEIR WEB SITE AT WWW.SQUARED.COM. FLOOR TROUGH TO HAVE GASKETED REMOVABLE COVERS WITH TILE TRIM TO PREVENT ENTRY OF LIQUIDS. CONTACT MANUFACTURER FOR ALL ROUGH IN SIZES REQUIRED. ALL TROUGH SHALL BE FLUSH WITH FINISHED SURFACES UNLESS OTHERWISE SPECIFIED AND PROVIDED WITH REMOVABLE, OVERSIZED, COVERS THE FULL LENGTH. COVERS SHALL BE CLEAR OF ANY OBSTRUCTION FOR INSERTION OF PRE TERMINATED CABLES. IF IT IS NECESSARY THAT THE TROUGH BE SURFACE MOUNTED, WHEN NOT INDICATED ON THESE PLANNING DRAWINGS, ALL EQUIPMENT PLACEMENT AND TRAVEL CLEARANCE MUST BE VERIFIED TO PREVENT EQUIPMENT AND TROUGH INTERFERENCE AND POSSIBLE EQUIPMENT DAMAGE. CONTACT GAMMA TECH, INC. FOR PROPER VERIFICATION OF EQUIPMENT PLACEMENT AND TROUGH CLEARANCES. PROVIDE TWO DIVIDER STRIPS WITHIN TROUGH FOR SEPARATION OF HIGH TENSION X-RAY CABLES, POWER AND LOW VOLTAGE CABLES WHERE REQUIRED AND PROVIDE APPROPRIATE CROSSOVER TUNNELS. "SWEEP ELBOWS" FOR CORNER BENDS TO BE PROVIDED BY ELECTRICAL CONTRACTOR. FLUSH MOUNTED ELBOW: SQUARE D CAT. NUMBER "RWT-SFEE" SURFACE MOUNTED ELBOW: SQUARE D CAT. NUMBER "RWT-SSEES" FACILITY: Florida Hospital Zephyrhills, FL DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: N.T.S. SHEET: E=6 1 1 1 1_ _ 1 1 CONDUIT RUNS ARE SHOWN SCHEMATICALLY EC SHALL ENSURE THAT CONDUIT RUNS ARE AS SHORT AS FIELD CONDITIONS WILL ALLOW. (FOR CLARITY OF CONDUIT RUNS, SOME WIRE TROUGH IS NOT DEPICTED) NOTE: REFERENCE TO "SEALTITE" BRAND MEANS REDUNDANT GROUND, PVC COATED, FLEXIBLE METAL CONDUIT. NOTE: THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR DIVIDING ALL JUNCTION BOXES AND CONNECTING TROUGHS TO MEET LOCAL AND FLORIDA AHCA REQUIREMENTS. FLUORESCENT LIGHTS / FOOT PEDAL DETAIL ( CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) 3/4" CONDUIT SF TO ELECTRONICS RACK CABINET THROUGH CONDUIT OR TROUGH / RACEWAY. (3 WIRES FOR FLUORESCENT LIGHT CONTROL) FITTON & Florida Hospital Zephyrhills, FL POWER SUPPLY TO FLUORESCENT LIGHTS REQUIRES HOUSE POWER DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 CEILING LINE NOT TO SCALE SCALE: 1 /4" = 1 ' SHEET: RACEWAY & WIRING SCHEDULE ( CONTRACTOR FURNISHED -CONTRACTOR INSTALLED) RUN # FROM TO SIZE REMARKS 480VAC, REFER TO "INCOMING WIRE SIZE WITH TEAL PCDU-ORF POWER CONDITIONER "NOTES. < > 3-PHASE, A VARIES EC SHALL CONNECT BOTH ENDS. SOURCE 3-#1AWG, 1 #1AWG NEUTRAL AND 1-#6AWG GROUND. EC SHALL CONNECT AT (A) AND 2 A CEE 1 11/211 CONNECT TO POWER IN TEAL CONDITIONER WITH SEALTITE CONDUIT TION BOX (E1) ANDNAL BETWEEN JUNCNPUT REAR OF TEALUNIT. 1/211 2-#14AWG PLUS GROUND. EC SHALL CONNECT TO SHUNT TRIP DEVICE IN (A) 3 > B ( A CONDUIT AND CONNECT "EMERGENCY OFF" SWITCH IN BOX (B). DRIVEN VERTICAL GROUND (WELDING BLE). EC SHALL CONNECT TO DRIVEN GROUND ROD 4 GROUND RISER 1 1/2" AN�OAWG TO COPPER BUS BAR (MG )AREFER TO BUS AR BLO K DIAGRAM. ROD CONDUIT 1/211 2-#14AWG PLUS GROUND. EC SHALL CONNECT TO DOOR INTERLOCK SWITCH AND <57 N ) w () CONDUIT LEAVE TAILS AT (J) PASS THROUGH BOX (W) . INSTALL ONLY IF REQUIRED BY PREVAILING CODES OR REQUESTED BY CUSTOMER. VERTICAL 1/2" 2-#14AWG PLUS GROUND. EC SHALL CONNECT TO "X-RAY IN USE" WARNING SIGN <6> ()w RISER CONDUIT AT BOX (W) AND LEAVE TAILS AT (E). EC SHALL ENSURE NO LIVE WIRES IN (E). INSTALL ONLY IF REQUIRED BY PREVAILING CODES OR REQUESTED BY CUSTOMER. VERTICAL THREE 2-1/2" OMEGA FURNISHED CABLES TO BE INSTALLED BY X-RAY EQUIPMENT INSTALLERS. <7> (rm RISER CONDUITS CONDUIT FOR MONITOR INTERCONNECT CABLES. EC SHALL LEAVE PULL STRINGS. WIRE ONE 5" MOUNT CONDUIT FLUSH WITH THE FINISHED FLOOR LOCATED WHERE SHOWN AND 8 G TROUGH CHASE NIPPLE CONNECTED TO WIRE TROUGH BELOW THE FLOOR. CONDUIT FOR C-ARM CABLES. WIRE TWO 2-1/2" MOUNT CONDUITS FLUSH WITH THE FINISHED FLOOR LOCATED WHERE SHOWN AND 9 T TROUGH CHASE NIPPLES CONNECTED TO WIRE TROUGH BELOW THE FLOOR. CONDUIT FOR TABLE CABLES. OMEGA FURNISHED CABLES TO BE INSTALLED BY X-RAY EQUIPMENT INSTALLERS. 10 VARIES VARIES VARIES X-RAY TEAL 1 1/2" E.C. SHALL PROVIDE AND INSTALL 3-#1AWG, 1 #1 NEUTRAL AND 1-#6AWG GROUND. EC 11 > GENERATOR UNIT SEALTITE SHALL CONNECT TO CIRCUIT BREAKER ON LOAD SIDE OF TEAL UNIT AND CONNECT TO INPUT POWER TERMINALS IN X-RAY GENERATOR CABINET WITH SEALTITE, PLUS TWO CONNECTORS, BETWEEN TEAL UNIT AND REAR OF X-RAY GENERATOR. TEAL 1/211 E.C. SHALL PROVIDE AND INSTALL THE FOLLOWING: 2-#10AWG AND 1-#10AWG r� 12 RACK CABINET UNIT SEALTITE GROUND. EC SHALL CONNECT TO TO CIRCUIT BREAKER ON LOAD SIDE OF TEAL UNIT AND CONNECT TO INPUT POWER TERMINALS IN I-100 RACK CABINET WITH SEALTITE, PLUS TWO CONNECTORS, BETWEEN TEAL UNIT AND REAR OF RACK CABINET. E.C. SHALL PROVIDE AND INSTALL 2-#10AWG AND 1-#10AWG GROUND. EC SHALL 13> �CK TEAL 1/211 CONNECT TO 15AMP, 1 P, CB IN TEAL UNIT (SURGICAL LIGHT) AND LEAVE 10' TAILS AT CABINET UNIT SEALTITE RACK CABINET WITH SEALTITE, PLUS TWO CONNECTORS, BETWEEN TEAL UNIT AND REAR OF RACK CABINET. REFER TO TEAL UNIT DETAIL AND DETAIL ON SHEET E-9. TEAL 1/211 2-#14AWG PLUS GROUND. EC SHALL CONNECT TO 20AMP, 1 P, CB IN TEAL UNIT 14 IMAGING UNIT SEALTITE (IMAGING CABINET). CONNECT TO TEAL UNIT WITH A 6FT. PIECE OF 1/2" DIA. SEALTITE. CABINET VERTICAL 3/4" 2-#14AWG PLUS GROUND. EC SHALL CONNECT TO SURGICAL LIGHT AND LEAVE 10' 15 C.ZF-) RISER CONDUIT TAILS AT RACK CABINET. REFER TO TEAL UNIT DETAIL AND ELECTRICAL DETAIL ON SHEET E-9. FINISHED CEILING LINE (TYPICAL). FINISHED FLOOR LINE (TYPICAL). CONDUIT RUNS ARE SHOWN SCHEMATICALLY EC SHALL ENSURE THAT CONDUIT RUNS ARE AS SHORT AS FIELD CONDITIONS WILL ALLOW. FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: SCALE: Dare Moser 1 /4" = 1' DATE: SHEET: 01.30.2012 FILE NAME: FHZ122011 DIGITAL SYSTEM ELECTRICAL DIAGRAM X-RAY E C OPERATORS CABINET WORKSTATION 10 10 MONITOR C nD nD KEYBOARD 8 DIGITAL FLOOR MOUNTED G D COMPUTER POSITIONER ISOLATION 0--c TRANSFORMER CAMERA D D E AUTO IRIS 7 TOUCH PAD 7 �mj OVERHEAD CMONITOR CARRIER USING 'W' AS A JUNCTION BOX FOR THE AC POWER SOURCE DOOR INTERLOCK SWITCH WIRES VOLTAGE VARIES ELLIMINATES AN ADDITIONAL CONDUIT RUN TO THE SYSTEM CABINET PULL BOX. ALTHOUGH THIS DECREASES 1/2"C CONSTRUCTION COSTS, IT IS NOT REQUIRED. 2414 1-#14G 1 /2"C 1 /2"C N 5 w 5 2-#14 JB 2414 1-#14G 1/2"C 1-#14G OVERHEAD 6 M MONITOR 2-#14 TABLE 1-#14G 10 UPS IMAGING CABINET N ^v-- l.r/1RRICR T t C X-RAY 7�� CONSOLE �J) J j ELECTRONICS RACK CABINET J ri-) G FLOOR MOUNTED G POSITIONER �Ej E X-RAY CABINET E 13 1 E IMAGING CABINET 11 v� 120VAC, SINGLE PHASE, POWER SOURCE (TEAL UNIT) n ELECTRICAL GROUND WIRE REQUIREMENTS ( CONTRACTOR FURNISHED -CONTRACTOR INSTALLED) (p) � #10 IMAGING CABINET X-RAY GENERATOR #6 > (E) (M) � #10 MONITOR CARRIER POSITIONER #8 � (G) (T) #8 TABLE RACK CABINET #8 � (J) (B) #14 #10 MISC. > ELECTRICAL (A) #6 DEVICES (El) #6 TEAL CONT�� (C) MGB CENTRAL GROUNDING COPPER BUS BAR. EXACT LOCATION BY OTHERS. ELECTRICAL BLOCK DIAGRAM SURGICAL LIGHT 480VAC, 112.5KVA, THREE PHASE, POWER SOURCE. TEAL P( POWER CC 90A, 3P CB - GENERATOR 30A, 2P CB - RACK CABINET 20A, 1 P CB - RACK CABINET 20A, 1 P CB - IMAGING CABINET 15A, 1 P CB - SURGICAL LIGHT 15 12 E u DRIVEN GROUND ROD G N TEAL UNIT SECONDARY 120VAC POWER O -O 15A DETAIL # SL101711 �J PLAN VIEW EMERGENCY OFF N FRONT VIEW EMERGENCY OFF BUTTON DETAIL NOT TO SCALE '-- SINGLE GANt-' Q n V (SUPPLIED BY COr PLATE & OFF BUTTON FURNISHED BY CONTRACTOR SIDE VIEW FOOT SWITCH CABLE THROUGH CONDUIT OR TROUGH /RACEWAY. ELECTRONICS CABINET FOOT SWITCH � J T El J J Z RELAY WITH N.O. CONTACTS 3/4" SEALTITE 3/4" CONDUIT SURGICAL LIGHT SURGICAL LIGHT / FOOT PEDAL DETAIL ( CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: SCALE: Dave Moser N.T.S. DATE: SHEET: 01.30.2012 E _ FILE NAME: FHZ122011 � DOOR SWITCH / WARNING LIGHT DETAIL ( CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) (NOT TO SCALE) LAMP VOLTAGE CAN VARY. REFER TO ARCHITECT'S DRAWINGS REGARDING HOW TO SUPPLY POWER TO (W). 1/2" CONDUIT ufl OPTIONAL WALL SWITCH TO BE LABELED "WARNING LIGHT" CEILING LINE TYPICAL WARNING LIGHT CIRCUIT A TYPICAL'X-RAY IN USE' WARNING SIGN CIRCUIT IS DEPICTED BELOW. DUE TO MANY VARIBLES, THE "X-RAY IN USE" WARNING SIGN CIRCUIT MUST BE COORDINATED BETWEEN THE EQUIPMENT SUPPLIER, ELECTRICAL ENGINEER AND THE FACILITY. THE ELECTRICAL CONTRACTOR SHALL CONSULT WITH THE FACILITY AND THE EQUIPMENT SUPPLIER PRIOR TO INSTALLING THE "X-RAY IN USE" WARNING SIGN. CB PANEL (�, 1 JB o SW �J 120VAC 1/2" CONDUIT POWER W 1/2" CONDUIT F__L_ ----1 0 N TO (J) GENERATOR CABINET. WIRES SHALL NOT BE LIVE. REFER TO WARNING LIGHT WIRING DIAGRAM DETAIL. FLOOR LINE X-RAY IN USE WARNING SIGN NOTES: OPTIONAL X-RAY IN USE WARNING SIGN MAY BE MCPHILBEN OR EQUAL. EXAMPLE MODEL NUMBERS: 30VIl P12WRW - X-RAY IN USE. (INCANDESCENT, SINGLE FACE, 120 VOLT) 30VL2PWRW - X-RAY IN USE. (LED, DOUBLE FACE, 120/277 VOLT) MAXIMUM 20 WATT INCANDESCENT BULBS RECOMMENDED FOR WARNING LIGHT. (DO NOT USE FLUORESCENT FIXTURES) CONTRACTOR SHALL CONSULT WITH FACILITY REGARDING EXACT WORDING, STYLE AND LOCATION. OPTIONAL X-RAY IN USE WARNING SIGN TO BE INSTALLED ONLY IF REQUIRED BY PREVAILING CODE OR REQUESTED BY CUSTOMER. DOOR SWITCH NOTES: OPTIONAL DOOR SWITCH TO BE SQUARE D "CLASS 9007, TYPE AO" OR EQUIVALENT TO BE LOCATED ON HINGE SIDE OF DOOR JAMB. OPTIONAL DOOR SWITCH TO BE INSTALLED ONLY IF REQUIRED BY PREVAILING CODE OR REQUESTED BY CUSTOMER. IN CASE OF A DOUBLE JAMB, ONE DOOR SWITCH SHOULD BE LOCATED ON EACH SIDE. SEE TROUGH / RACEWAY LAYOUT FOR DOOR SWITCH / WARNING LIGHT LOCATION IN ROOM. SEE POINT TO POINT WIRING DESCRIPTION FOR WIRE SIZES TO BE USED IN CONDUITS. USING 'W' AS A JUNCTION BOX FOR THE DOOR INTERLOCK SWITCH WIRES ELLIMINATES AN ADDITIONAL CONDUIT RUN TO THE SYSTEM CABINET PULL BOX. ALTHOUGH THIS DECREASES CONSTRUCTION COSTS, IT IS NOT REQUIRED. WARNING SIGN NOTES: OPTIONAL WALL SWITCH (SW) MAY BE CONTRACTOR INSTALLED AT THE REQUEST OF THE CUSTOMER OR EQUIPMENT SUPPLIER. PURPOSE OF WALL SWITCH IS TO REMOVE ALL VOLTAGES FROM GENERATOR CABINET DURING SERVICE. EC SHALL CONSULT WITH CUSTOMER AND EQUIPMENT SUPPLIER REGARDING WALL SWITCH INSTALLATION, TYPE AND EXACT LOCATION. DETAIL #WL02.0310 X-ray On Warning Sign Circuit Options NOTE #WLN02.0510 The engineer of record shall consult with the facility and equipment supplier to coordinate the x-ray on warning sign circuit combinations. Majority picks marked by an asterisk. Housing Lamp Faces Surface Mounting Wording a. White * Incandescent* Single * Wall * Surface * X-RAY IN USE b. Black LED Double Ceiling Flush X-RAY ON, etc. c. Aluminum, etc. Fluorescent Note: NEVER use fluorescent lamps Note: Recommend 20 watts or less Voltage Panel color Power source ON / OFF a. 120vac * a. red on white * Facility panel * Rotor prep b. 277vac b. white on red Systems supply System ON c. 120/277vac c. black on white Always ON d. 26vac d. white on black e. DC e. red on black, etc. Refer to detail number WLDO1.0310 for typical x-ray on warning light circuit. Refer to detail number WLD02.0696 for typical 120VAC TO 24VAC warning light circuit. 01, I L 0 0 2 0 A X—RAY ON WARNING LIG JUNCTION BOX G N X-RAY' IN USE Example "X-RAY IN USE" Warning Sign Circuit Options NOTE #WLN01.0310 Many potential factors influence choice of x-ray on warning sign. E.g. Matching existing; efficiency; aesthetics; price; quality; number of options; etc. Gamma Tech never knows the exact warning sign type, style, lamp voltage, power source, method or means of control prior to drawing set issuance. For this reason more than one detail may be depicted in this drawing set. It is our hope and intent to encourage the construction participants and the equipment suppliers / installers to coordinate efforts. For this reason we have listed some potential options and their caveats below. (not to be construed as all inclusive). Important decisions to be shared are numbered. Sample options are listed alphabetically. For your convenience, the majority pick is designated by the word 'typical' in parentheses. The facility or their designee selects an x-ray on warning sign. 1) Lamp voltage? - usually one of four options. a. 120vac (typical) b. 120/277vac c. 277vac d. Low voltage ac e. Low voltage do (battery) Note: The system installer should be informed of the lamp voltage as soon as possible. The facility determines at which point in time the warning sign will illuminate. 2) When to illuminate? - Engineer to coordinat with the facility and equipment supplier. a. Warning lamp turns on upon rotor prep / turns off upon x-ray termination. (typical) b. Warning lamp illuminates / extinguishes when equipment is switched on / off. c. Warning lamp illuminates 24/7. Note: the equipment being installed may or may not be capable of interfacing with a warning light or may have just one option. The equipment supplier shall coordinate with the facility and the construction participants regarding interface options. EXAMPLE WARNING SIGN / LAMP OPTIONS - DETAIL #WLD02.0696 HOUSING: ALUMINUM, BLACK, WHITE, ETC. FACE: SINGLE SIDE (TYPICAL), WALL SURFACE MOUNT(TYPICAL) OR RECESSED. DOUBLE SIDED, SURFACE MOUNT ON CEILING OR WALL. WORDING: "IN USE", "X-RAY IN USE" (TYPICAL), ETC. COLORS: RED LETTERS, WHITE BACKGROUND (TYPICAL), MANY VARIATIONS. LAMP TYPE: INCANDESCENT (TYPICAL) OR LED. DO NOT USE FLUORESCENT. VOLTAGE: 27 AC, 120 AC (TYPICAL), 277 AC, 120/277VAC, DC BATTERY. WATTAGE: VARIES. (20 WATTS OR LESS IS TYPICAL). ROTOR PREP N I RELAY WI TH N. 0. CONTACTS SYSTEMS CABINET IN THE EXAMPLE ABOVE, 120VAC HOUSE POWER IS SUPPLIED TO THE WARNING LIGHT. THE CIRCUIT IS NOT COMPLETE UNTIL THE ANODE, IN THE X-RAY TUBE, BEGINS TO TURN. WHEN THE EXPOSURE BUTTON IS PRESSED, THE ROTOR PREP SIGNAL IS ACTIVATED. AT THIS TIME THE "X-RAY IN USE" LIGHT ILLUMINATES. IT TURNS OFF WHEN X-RAY GENERATION IS TERMINATED. DETAIL NOT TO SCALE THE MAIN CONSIDERATION WHEN LEAVING WIRES IN JUNCTION BOXES IS TO ENSURE THEY ARE NOT LIVE AND THAT THEIR ASSOCIATED SWITCHING MEANS ARE LOCKED OUT (OR EQUIVALENT). THIS STANDARD SHALL BE APPLIED TO ALL OPEN ENDED WIRE AND CABLE MENTIONED IN THIS DRAWING SET. OBVIOUSLY, GROUND WIRE OR CABLE BEING THE EXCEPTION. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT WIRES ARE NOT ENERGIZED UNTIL THE EQUIPMENT INSTALLERS ARE READY FOR TESTING. THE ELECTRICAL CONTRACTOR SHALL INFORM THE EQUIPMENT INSTALLER(S) AS TO THE LOCATION AND MEANS OF ACTIVATING ALL SWITCHING DEVICES ASSOCIATED WITH THE OPEN ENDED WIRE AND CABLE MENTIONED IN THIS DRAWING SET. FACILITY: Florida Hospital Zephyrhills, FL DRAWN BY: Dave Moser DATE: 01.30.2012 FILE NAME: FHZ122011 SCALE: N.T.S. SHEET: E=1 0