Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3172 Moulden Hollow Dr
INDEX OF DRAWINGS SHEET DESCRIPTION SHEET No. CS COVER SHEET 1 FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS F1 FOAM DETAILS 4 ELECTRICAL PLAN 5 ROOF PLAN 6 FOUNDATION PLAN 7 ROOF FRAMING PLAN 8 LINTEL DETAILS SN STRUCTURAL NOTES SN1 DETAILS S3S STEM DETAILS S4 DETAILS S5 DETAILS SS RETROFIT DETAILS D1 SECTIONS & DETAILS WP WATERPROOFING DETAILS PA1.0 PRODUCT APPROVAL NUMBERS PA1.1 PRODUCT APPROVAL NUMBERS ABBREVIATIONS PA1.2 PRODUCTAPPROVALNUMBERS PA1.3 PRODUCT APPROVAL NUMBERS A.B. Anchor Bolt F.P. Fireplace P.T. Pressure Treated AAbove F.O.M. Face Of Masonry Pwd. Powder Room A//CC Air -Conditioner Ft. Foot/ Feet Red. Radius Adjustable ADJ. A.F.F. Above Finished Floor Ftg. Footing Ref. Refrigerator A.H.U. Air Handler Unit FIX Foxed Req'd. Required ALT. Alternate Galy. Galvanized Rm. Room B.A. Base Cabinet G.C. General Contractor Rnd. Ind BF Bifold Door G.F.I. Ground Fault Interrupter R/S Rod and Shelf Bk Sh BookShelf G.T. Girder Truss SD. Smoke Detector Bm. Beam Hdr. Header S.F. Square Ft Bot. Bottom Hgt. Height Sh. Shelves ❑ a B.P. Bypass door HB Hose Bibb SHT Sheet BRG. Bearing Cir. Circle Interior S.L. Side Lights Clg. Ceiling K/KI Wall Kneewall S.P.F. Spruce Pine Fir CJ Control Joint K.S. Knee Space Sq. Square p IF71 [E] El L] Col. Column LaLaundry S.Y.P. Southern Yellow Pine —11 Comm. Community Lay.v. Lavatory TB Towel Bar F1771 17 E7:1 E] Comp. Compressor L.F. Linear Ft. Temp. Tempered C.T. Ceramic Tile LL Lintel Length TThicken FE71 ❑ [71 D M E ❑ D. Dryer LT. Laundry Tub T.O.B..OBTop of Block F1 �7:1 DB Door Bell Mas. Mason T.O.M. Top of Masonry Dec. Decorative ry T.O.P. Top of Plate Ded. Dedicated Outlet Max Maximum Dbl. Double M.C. Medicine Cabinet TR TOWEL RING Die. Diameter Mfgr. Manufacturer TP TOILET PAPER Disp. Disposal Micro. Microwave Trans. Transom Window Dist. Distance Min Minimum Typ. Typical D.S. Drawer Stack M.L. Microlam U.C. Under Counter D.V. Dryer Vent Mir. Mirror UCL Under Cabinet Lighting D.W. Dishwasher U.N.O. Unless Noted Otherwise Ea. Each Mono Monolithic N.T.S. Not to Scale V. Shower Valves E.W. Each Way VB Vanity Base Elec. Electrical Opn'g. Opening Vert. Vertical Elev. Elevation Opt. Optional V.L. Versalam Ext. Exterior Pc. Piece VTR Vent through Roof Exp. Expansion Pod. Pedestal FBC Florida Building Code PH PHONE W/ Watcher Vy Fin. Mr. Finished Floor P.L. Parallam W/C Water Closet F.G. iced Glass PLF Pounds per linear foot W.A. Wedge Anchor Flr. Floor Pit. HI. Plate Height Wd Wood Fdn. Foundation Pit Sh. Plant Shelf WP Water Proof Flr Sys Floor System PSF Pounds per square foot REVISIONS 08-20-15 1.00 NEW BASE PLAN ALL SHALL COMPLY LDING CODffH P��rAluNe CODES'FLORIDA �uIL�IIRdG CODES NATIONAL ELEr,-r 1c:, t ;ODE, 12-8-15 2.00 ADDED VAULT. CLG. AND THE Cif CE E,PH�lRHILLS ORDINANCES REVIEW DATE ` CITY OF MPH H# LS PLAN INE MEAN ROOF 15 FT. HIGH TYPICAL FOR SINGLE STORY HOMES MEAN ROOF 30 FT. HIGH TYPICAL FOR 2 STORY HOMES THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID Notice to Builder & All Subcontractors 11718M It is the intent of Designer/Engineer listed in the titleblock of these documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Critice at (407) 880-2333 immediately. No backcharges will be 1941 considered for reimbursement by the Designer/Engineer without advanced notification and approval by the Designer/Engineer. Payments will be made in accordance to the terms of the agreement. LOG 0 z Z— a 10 o Z Q J Z � (9 C w Q U — w 0 = 0 o 0 i�to U a)M w E 2 •O_ M Oo 0 _ a MI�3 II UaY r�00 Sa o� CM QoOcr A1 N-C B-D C ff I fOA N _ Z o..n N o C °4 Z o'. Z /may 0Mrn a Co, � LL Nv O � ai -a: 6:.O DI 016 L Z thew Qt N IY NaM tk b � D U O 00 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 1f O z O >(5MD M a L � V) Q � -2 Ln C- f— � U a 00 Q � � Z J � W d z zaa f a a�� �z0, Z z 0 .0J �g 8UJ LU LU ~o� oZ T 'T Q U �>, a M w g o O U V� a _ °oz P2 ¢ Om� C a CV baoa z W �3 J Z ^ f o o� 0 z w Lra r-4 w Q L lozu I di 2 �2 � Q z z WLuz a = RZ CIOg O1 z W = <o z a "i i1 Ul) g SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION NO. 10 SHEET NO. CS -- — — w.i - 1 11-1 -- I— iI — - r, - . _ I n r ,air 1 ' �. . �il� I L� -II F17. 1_.d ,I II� L. 4�dlu. G s., � I�� II lu 65'-0" A D S3 14) H.B. r I 0 0 5-SH =, 6" DPT ---- R& — — — — = BUILDER TO N PROVIDE I I W.H. APPLIANCE I I ( I I I I O PROTECTION I I I jWHEN � OWNER'S SUITE W.I.C. I REQUIRED 2-4,PER FBC 1 1 I I i � ■ ;B . °' Cq s'-o" CLG. CARPET 8 CLG. CARPET 2 CAR GARAGE TIE = �;,, I I I OU)z 17'-0 ! r T_8r I cr 8'-0" CLG. 20'-08" - 2668 I I I 8 I $ I i 91168- HANSON I I p l l 4 BOX @ 36" I I EDGE OF SLAB 2" -- CC A.F.F. I BEYOND WALL •�.r 1 O= I I I 0 rn •- 60"x36" DRYER VENT K S3 0 I w I I cv SHOWER THRU ROOF-1J I O^ I I 00G 00 S3 (4) 2x4 #2 SYP STUDS FIBERGLASS "'�° -- R&S I I x I I a W/ USP HTT4 @ BASE SUKROU D T I l l l I I TYP @ 1 STORY I A 5'-4" 4'-0" I PT. W OPT. D I I I I S3 I I/xI NOTE: FINISHED � I AHU � _ � � u Q QW WALLS TO BE 1 L — — J I FLUSH. VERIFY IN I 1 1 I m �I to _ rr yY 1 I FIELD. I I '- ILE ----- ----- _ 00 K (4) 2x4 #2 SYP CC D S3 STUDS W/ USP S3 S3 T f i868 R.A.G. HTT4 @ BASE FAMILY RM c 2:12 VAULTED CLG. _ 9'-4" CLG. CARPET m I C 3068 �to ; i9'-41 ' j f ENTRY 6 c LID ItoI r 23'-08" in T-10" T-8" 10'-10$" c, 6" " 8'-0" CLG. I— I ' I —HDR AT T-4" i ------- _ -------R&S------ 2668 'c�° _ oleo = R&S 2668 T '------------- r T 4'-0" 1 V-7$ V-10" C4 4'-7" 8'-8" N 51-4 `) 14'-6" 5'-4" �' I a T-6" N I 5068 B.F. I 4068 B.F. r _ )PT. I — -- ------ 14 REF. BEDROOM M N ��00 W�o s PATIO CAFE 8'-0"CLG. BE7R�aO M 3 T J' PBEDROOM 4 / W r---� I 8'-0" CLG. CARPET Q I D.W. I °O °� If i CARPET I I �� 8 -0 CLG.0o ~ =C cnw M� O o — LO W O / I � U a�- 24 - Is 1 I CARPET I - C I ILE' ,,, r> CARPET c7 w SI Kw/ ISP C00 D u�i �N 20'- I .. j 2' " 10'-4" T 101 2'4 jI i, 12'- " / oo IP 2" I 00 TYP @ 1 rn T -ib ■ I / iv PANTRY W c STORY �_ _ T L ui� A / 36 ' 36F '- I FIBERGLASS AG e� °Q S3 AC PAD / — — — — — O ---� r 5-SH 16" DEEP i SURROUND N H B EGRESS A EGRESS O S3 O 4-Ifli HEADER SCHEDULE MARK HEADER SIZE REMARKS H1 (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE H2 (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE H3 (2) - 2X10 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE H5 (2) -1 3/4- X 11 1/4 LVL 2.0E Fb=2950 H6 (2) -1 3/4" X 91/4" LVL 2.0E Fb=2950 H7 (2) -1 3/4" X 16" LVL 2.0E Fb=2950 (2) -1 3/4- X 71 /4" LVL 2.0E Fb=2950 (2) - 2X4 #2 SYP W/ 1'/2" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required * VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED ** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20X26 18}X25i S.H. 13 20X38j 18}X37i S.H. 14 20 X 501 18 J X 50 S.H. 15 20 X 63 18 J X 62 i S.H. 16 20X72 18�X71� S.H. J 32 271/4 X 26 26 X 25 J S.H. j 33 271/4 X 38 i N/A S.H. j 34 27 1 X 501 N/A S.H. j 33 N/A 26 x 37 1 S.H. 34 wA 26 x 50 S.H. J 35 27 J X 63 26 X 621 /2 S.H. J 36 27 J X 72 26 X 71 1/2 S.H. 22 37 J X 26 36 J X 251/2 S.H. 23 37 J X 38 } 36 j X 37 3/4 S.H. 24 37 J X 50 1 36 j X 50 S.H. 25 37 J X 63 36 J X 621/2 S.H. 26 37JX72 36JX711/2 S.H. DOUBLE 2 WIDE 75" TALL 73 J WIDE S.H. 32 54 X 26 52 J X 25 1 S.H. 33 54 X 381 52 JX 37 1 S.H. 34 54 X 501 52 J X 50 S.H. 35 54 X 63 52 J X 62 i S.H. 36 54 X 72 52 j X 71 j S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 1 3/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors, equipped with self -closing device. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.11, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: Is From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is Iocated.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic , crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" Oq +25.6 / -27.8 © +25.6 / -34.3 © +24.5 / -26.7 © +24.5 / -31.9 �E +23.0 / -25.2 (F +23.0 / -28.9 GO SEE SN SHEET HO SEE SN SHEET 140 MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALL LEGEND TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "A1" 1ST FLOOR LIVING AREA 1936 LIVING TOTAL 1936 GARAGE 416 FRONT ENTRY 20 TOTAL AREA 2372 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONC WALL R-4.1 HIGH PERM EX I FRAML Z X 4 R-11/R-13 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION I R-11/R-13 KRAFT FACED (GARAGE / LIVING) Hal V 1 Z o —0 Z Q o.. z Cz w p U — Ow ~ V) �� = o0 U 0) W E — 8 C Ri M m ;a M O 6 all wi U� O LLCO 0,Q00 �Y Q rn u7 O � 0) A' NC •B D•C v.. C' CN Me -�g�� vwY,—w� �NOD Z.0p�' HE In 9 ca UM A j2 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 11 O Z O 0 Q i>i U-) M O M Q z WON L.L. !2 oC V p- 00 a z J � W J 1Z IN za �¢ ¢&� r480 zW w FS z Z CfLU o Q �iMz@ 6Wo aZ zz zzfz s C N M J LL cn 3 o ;d � 0 UCL = W r � a �pz :W T N Lu W< z 6 Q a�Q z z s�o a " � w Ln Ln Q w z a o z u 2�a wiz z ��Z a � �Z g W J J Z a US o T, SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 2s0 SHEET NO. 1.0 9--1118" MIRROR — ----- MIRROR 7 ---------- 00 F 00 F- "8 LA 7 L 0 O LL===4 II OWNER'S BATH OWNER'S BATH BATH 2 N ILJ cr) INV— LJ HOOD chi LJ o 9 N ao F 4=1 I I DW OPT. RANGE REF KITCHEN ISLAND KITCHEN KITCHEN INTERIOR ELEVATIONS_ SCALE: 1/2"=1'-0" (D � a z 0co 0 z CD z 0- U) z V) CD (3) C-�o 4-j LU U 0 Ui 1- E U 0 Ln co cnc,) 0 OC=) WCO U-1 r- 0) M ce) ce) E 2 M C') 0 0 8 LLB Rig a) :3 6 0) 0 4) Q) -�e t.- a) a 8 Y Ln 0 --t <0 -'r CL cm A NCB -DC D. AO- Aj 0. S (r--p 1An �,- \. -9. C o CP 1 LL * , LLI 0- C -)NCU z S6P.- t4, 0 cp LL CZ"I<ft— To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) C) Z 0 > o V) Lr) U) 0 e--s U// U CL 00 z < E WC) O CM 0, z- z z C) 0 � ()� L) uj LU Q� !U z Z< EDZ LZLI - LU .Z-,, F- 1, '-3) L.0 z z 0 U > 0) z ZEL z C: O -0 C: LU 0 fu U, 0 2 E8 2 OR, .11 -< :<1 Z C=), Z zz,: � Uj Ln �,i -LE 8 LU 0zU fV fa /11 rl U 1,0 Z v- Z U Cal LU 0 W SCALE AS NOTED DATE 2/24/2014 TECH: FGUZMAN VERSION NO' 2n0 SHEET NO. 2.0 � a z 0co 0 z CD z 0- U) z V) CD (3) C-�o 4-j LU U 0 Ui 1- E U 0 Ln co cnc,) 0 OC=) WCO U-1 r- 0) M ce) ce) E 2 M C') 0 0 8 LLB Rig a) :3 6 0) 0 4) Q) -�e t.- a) a 8 Y Ln 0 --t <0 -'r CL cm A NCB -DC D. AO- Aj 0. S (r--p 1An �,- \. -9. C o CP 1 LL * , LLI 0- C -)NCU z S6P.- t4, 0 cp LL CZ"I<ft— To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) C) Z 0 > o V) Lr) U) 0 e--s U// U CL 00 z < E WC) O CM 0, z- z z C) 0 � ()� L) uj LU Q� !U z Z< EDZ LZLI - LU .Z-,, F- 1, '-3) L.0 z z 0 U > 0) z ZEL z C: O -0 C: LU 0 fu U, 0 2 E8 2 OR, .11 -< :<1 Z C=), Z zz,: � Uj Ln �,i -LE 8 LU 0zU fV fa /11 rl U 1,0 Z v- Z U Cal LU 0 W SCALE AS NOTED DATE 2/24/2014 TECH: FGUZMAN VERSION NO' 2n0 SHEET NO. 2.0 HEEL 12 5� 12 �5 T.O.M. HDR HGT. TEXTURED c CEMENTICIOUS 50 FINISH ON C.M.U. (TYP.) F.FL. J 14'-0" RIDGE VENT -------------------------------------------------- 1'-0" 2'-0" 12 Z�_5 12 �5 if-1511 VIbIrI M1=11y 3 TAB SHINGLES. ROOF INSTALLED AS PER MANUF. SPECIFICATIONS 1'-0" I% FRONT ELEVATION - Al 3 TAB SHINGLES. ROOF INSTALLED AS PER MANUF. SPECIFICATIONS T.O.M. HDR HGT. 6" FASCIA (TYP) TEXTURED CEMENTICIOUS FINISH ON C.M.U. (T'P.) F.FL. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CO co N SCALE: 1 /4"=V-0" LEFT ELEVATION - Al General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION "G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ pordand cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or comics vents. "CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SO. IN. OF NET FREE AREA/ FT. " (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. "Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) 19 = Linear Ft. of De& Air Needed) • allAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT -Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 88.25 = Amount of O'Hagin Vents Needed z o — o zID N z IDQE3 00 z V1 (9 ID(O N w 0 U — w O D_V) .E F_ 0 � (0 C) U w F-� all m'M C M Cl) OoN U LLCC) Q Q Ja' cn 0 0) Q 0 A, DD N�C� D•C et ik � ) aV `J • \� c� C,4 9�eY'� _M N r - ID M 4 F+� 0 Co CPA E a M i N m ` CCU SS1O z W��31144411``� a o 00 U To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD CD Z fV O (3) r-1 i--' •_' O > jr M C�' +M a (n 170 Ln a � •L Q CL� +M U fCL a OC) Q E Z C:) WJ �R 3� w zaa z� f a f— v, 55480 z 0 O of �ZZ 0 LU > �No i- LIV _l } o r V ' �..L.J f z Z r—� LLI 5 p 0� M U) O _0 �./ •— I C: p z ZoZ J Q W U = (o Q ~ f o� aU- Zo¢ 0 O �0� LL ¢z< ��p Q Z � ��o Z W rl Lf1 IJ.J a �Z a oE � J L11 ozo 0) Q Z jWZ �z *k t7u R z o Z g = <z r, SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION No' 10 SHEET NO. 3.1 0 00 EX Tr) M 1'-0" 12 5� 12 �5 EXTENDED OVERHANG TO BE CENTERED — ON DOOR 3 TAB SHINGLES. ROOF INSTALLED AS PER MANUR SPECIFICATIONS TEXTURED CEMENTICIOUS FINISH ON C.M.U. (TYP.) REAR ELEVATION - Al SCALE: 1 /4"=V-0" 3 TAB SHINGLES. ROOF INSTALLED AS PER MANUF. SPECIFICATIONS 15'-0" RIDGE VENT 12 14'-0" RIDGE VENT 12 :!�5 HDR HGT. TEXTURED TEXTURED CEMENTICIOUS FINISH ON C.M.U. FINISH N C.M.U.2'-0" (TYP-) FINISH ON C.M. (TYP.) F.FL. RIGHT ELEVATION - Al General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION "G.C. VERIFY ROOF PITCH'" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Reslsitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (papefbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by save or comice vents. "CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS - 138 SO. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SO. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. " (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) 172 = Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roof) - 9 80. IN. OF NET FREE AREA / FT. "Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) 19 = Linear Ft of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT Formula: (Sq. Ft Soffft Needed) x 7 = (Sq. in. Needed) / 86.25 =Amount of O'Hagin Vents Needed �r Z M 0 —0 Z CD Z Q J U, Z V) C.9 crs 4--J Lu C) U — Ow 0 �%) o 0 ►- U m 0M w —c4 aim M C @ M N Z7co 000 ID N L LLoo � Y r1_ tyo Q rn �Qv rnQ o A� BD® N,C 6,D C r—ft ., sit ii N\\` co CO �N� �Ca�r� -.. u_cc _ r -+ CCU 0 i E �I Iu O P� $ S " lei ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 O Z r4 O a r-'-r --' O > O O C:)��—+HMO M In M LP) O Q L_ I.L. � O" � M Icy- U a 006 Q � E z� WJ � CI' tR w za vJ ~ Z Z ¢"� I�zOp z� _O � 0 ul J J ■ , > W g O I o L J wLLJ oZ y O /r \ Q IFC0 : M U) �E 0 -0 i p Z o JQ Ov =fo ^ I..L w o� � R o a I- W 186 b�0 UJaa3 < Z � �wfo Ce Q�o W J Ln T. l LLI a a o I- U-1 Z z H < W � H T V , k Z w z a Q Q J = z ¢ z r1 ,-1 i2 to SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 2.,0 SHEET NO. 3.2 2" 1" 2" *NOTE: VARIES .10 RADIUS S FOAM TO BE USED ONLY WHEN " 31/2 RADIUS 1/2p RADIUS REQUIRED BY COMMUNITY =N � 3/4" RADIUS elt e N M ;0, io SPECS. IF NOT, 1" 2" OPENING VARIES 2" DETAIL TO BE N 1/2" RADIUS N BUILT W/ STUCCO. 1" 4" VARIES 1' EDGE OF OPENING ;- c VARIES 0 r in = T (V „ VARIES 4" 3 „ J„ 4" 42 a 2„ 1 1/2" RADIUS 13�" VARIES 4KN r oA� a e � W M„ya � is VARIES 1"rr = 11^ 32n u u 1n 2 1/2" RADIUS t T Tx D3" BASE I • • 8" 2" 4" *NOTE: VARIES e� 1" 3x FOAM TO BE USED ONLY WHEN REQUIRED BY COMMUNITY SPECS. IF NOT, 1" OPENING VARIES 2" DETAIL TO BE 2rr 2" _ d'N 1,-6„ 1" 1" 1'-4" �O tO io BUILT W/ STUCCO. EDGE OF Err Pi OPENING e • T 2rr � Eli 4" 10" O r CV 24r 10" s" _ N 1-1/2" THICK 1-1/2" THICK v e toe e KV -tC i— C% T Li r" V �x 2 2^ 4rr 3^ 2rr 2rr lV I w a w � 1-1/2" THICK 24" e v T �n 2'-4" 1 �-5n �" .7� 31" 4 1 r4x 3" 4 N e _ � "IN17 � 3„ N w 2 ^ VARIES VARIES cr 01 I NOINSTALL OVER STONE, TYP. go P 6= 4" �+ CV ED a RQ = • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH • FOAM/ EPS MATERIAL IS ACCEPTED VARIES ` 2" KEYSTONE F11 0 OPTIONAL VARIES 4" GARAGE DR. OPENING 4" NOTE: • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH 1" 1'-6j" 1" 12" • FOAM/ EPS MATERIAL IS ACCEPTED VARIES 3'-8" 1x 4" 3'-0" 4" 10" 1'-4" 10" s T c T f2" 0o co e N KEYSTONE F11 OPTIONAL °D !Q'E N 3J-r c , CV ' 4" WINDOW OPENING 4" 9:9 ill-1 p L 51" 1 r-1l r 4x �7� "4 7- - _ 9 GENERAL NOTES: 1" Rro" iv 1r� e p,° • POL 1.5 BDENSITYOAM COAT(H (HARD COAT) • ACRYLIC SAND FINISH Z co 0 y L __j Z V) U Q) U—) (DIM w C) U O w F- 0 = Cl) r i� mN U w 1� — 8 rnM Cl) C cc M N 'O M 0so U N LL 00 0 Y. U) a o �o am �Q� rn¢0 BD® NC,B,D,C �. � N N � N V p O Z oZ W�N�aCU- (Aim� `� O M a M a m WW a¢L a Z 0 vrno' o¢ p f v y o^o Z O m m 0) W �QNB �' rh �o 0, U E-- ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. ON Z 0 (L) N > U O M R U) (U ern a.cn :2 v- ZQ LL oC U Q 00 z�� WJ C:) d' W za �a �2=o J P_zz 'Q 200-W t'--I 8 L W 0 FLUo o(n }O 2:z e J� T a 3 M o -0 _ � O a U = (�cc LL U f f" lam- o F ., W �ama rj u¢u.�oa Q Z Q Z �o W Ln a z W S � �--1 L1J � Q z 0 2U V , Q Z *k Z CO O _ z ¢z rn ,—I a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION NO' 10 SHEET NO. F1 n c€1I11 ridtiii i,:Ji,. 11,_ WH a 11— ., I , ., 17� 1111 I --� � Zil Idi l'.I ilPiia I I u, i ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. 200A INDOOR PANEL #14 copper to lights 8 aWats #12 copper to 20 emp dae 510-2 copper to WH #1"copper to Dryer MAIN O0 or 4/0 SER Alu 200 amp 150 amp CO. FEEDINTERSYSTEMe 11soonnLectPOWER Cu Ground BONDINGNDING WIRE TERMINATION PER WITH CODE APPROVED NEC 08, 250.94 CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC. GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. 1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in comer counters. ELECTRICAL KEY 0 DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER Ow P WEATHERPROOF DUPLEX OUTLET F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET $ WALL SWITCH 63 THREE-WAY SWITCH 4 FOUR-WAY SWITCH R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE } WALL MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE P.C. LIGHT FIXTURE WITH PULL CHAIN 3 TRACK LIGHT FLOURESCENT LIGHT FIXTURE Q EXHAUST FAN :Q EXHAUST FAN/LIGHT COMBINATION ®D ELECTRIC DOOR OPERATOR (OPTIONAL) CH CHIMES (OPTIONAL) El PUSHBUTTON SWITCH (OPTIONAL) SD SMOKE DETECTOR O SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) ® TELEVISION (OPTIONAL) ®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. O THERMOSTAT ELECTRIC METER a ELECTRIC PANEL DISCONNECT SWITCH ® SPEAKER (OPTIONAL) ROUGH -IN FOR OPT. CEILING FAN v J c� CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR L J OPT. CEILING FAN 69 (1) PHONE LINE, (1) DATA PORT WP H.B. GFI DISC. RECEPT. FOR ALARM SYSTEM NGNIIrA I GL.1 r[GI+Gr, I /1t,iLG FOR MICROWAVE RANGE HOOD PER SPECS VERIFY METER LOCATION WITH RI 111 r1CD ENTRY MAIN FLOOR ELECTRICAL PLAN I I it 1� �t, t1l 1 1 111; h LF-Iffl-T51h. r lit 1, 1 1, 111, 11 --T7— IFF-T- 1 - I FI--TTF-- SCALE: %4'=1'-0" a 0!� Z co 0 111111, —0 Z CO Z Q J U) Z , r/y (D(a �-LJ — ULLJ hO �UI)nW rlf = o co o0 U i W mi—3 n 0) cc 0 7 c c M 000 _ 6 = a:co S -00 CID U N �Y 0 U YC to OV Q rn rn Q o Als�af t e N C•B�D C . r_ ON N N fw V c r p m N N Q O Ci Z C Z Z. BE:—, )lN� U) IL ,6C W Wm_LL a.z O V¢ n 0) 5 9 ee"�� 0 � 0 E2 m °° � 9) Z Q d W . < m N U F- O ❑❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 11 O O Z N O n > U-) M O M � ro t1i a) n 'O a I�`" oC U fo a �� Z WJ CD Milli! W0 Za ¢a fF Z Qua U Z Z =ZZ J QLea J U W Z N o�z0 >✓ o61) }o I- fZ W S a M J w �3 o Z -p C: U = ('� J Q Lu Z O LL. ° 3 O^ Z m a N a of I++sz¢ Q Z W Ln LJJ �LL ' ¢o 01 Q Z F t%O Z ?LUz 0 o g = Z SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 10 SHEET NO. 4.0 VENTED SOF 46 SQ. FT. /r-6 i-rr-r1 ^r1r-r11T cA ~% r-T VCIV I CV JVrrl 1 V/ ow. r 1. ATTIC VENTILATION CALCULATIONS - Al ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED 1/150 Rule 1/300 Rule Ridge Off -Ridge (No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. Req.) (Ft.) Total Ventilation ATTIC Provided SPACE SQ. FT. Total SQ. SO. FT. SQ. IN. of by Upper SQ. IN, of of vented IN. of of ventilation to SQIN. of SQ. IN. of Ventilators ventilation soffit ventilation vented be provided . Ventilation Ventilation (See Eley ) required needed required soffit by upper needed ventilators Main 29.00000 1.000000 Floor 2373 2278 325 1139 81 570 0 573.0 435.0 138.0 (Zone 1) "NOTE" GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS REQUIRED BY FBC 5th ED. RESIDENTIAL. VENTED SOFFIT LEGEND IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF LABELED AS -VENTED-, NO FIRE PROTECTION WILL BE REQUIRED. rrrrq VENTED SOFFIT SOFFIT ROOF PLAN SCALE: /4"=1'-0" General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisltive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. Is Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or comice vents. "CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREAI FT. '- (Sq. Ft Soffit Needed) x 7 = (Sq. in. Needed) / 72 = Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roof) - 9 SO. IN. OF NET FREE AREA / FT. "Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 9 = (Unear Ft of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT "Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed 0LO z� o z Q J a z V7 0 ID(.0 •I--i w 0 U — w O � D_V) =3 0 U) M V7 r— 170 VU o Co rr` w — 0) M c N (n N a 0 O o Uto to L LLCc CU (0 C CL o r a -- Q o> rn Q o A 1 N,CBDC f'fPa Do ,.•' ti • ep cv .m00%obi MeN Lo �� 4VF_ G7 ant U_ C,M N \'l. c c LV %- PL ... � FC m� Q '' dPMF ai b LL 'J W N Q M 0 ❑❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O z (V O a) r-, in _ C:) r>-i to M fO 'O Q U,) 170 Lr) ♦2 toz .L LJF) a C U Q � � QY U00 a Q %oo E z� WJ CD 0 H WO za � Q z �MO0 U z jz LLI <Y E LU u_ w O 8 Z L 10 V) yo r> /L a U Z z a z N� C: M C:j °-a _ cu �2a — � o� ® 0 r{JXou N rr .ate Q ^Lr) I�aQa <��Q z z J ..ado LLJ 005 �-i LU Q Z r z 8sca uw�F z z tu � a Vz o S = <z uJ r 1 SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 10 SHEET NO. 5.0 TYP @ 1 STORY U.N.O. A S3 H.B. 3'-0" • • 1 r---------�- --- -_: ° -- ° --------�; - -- BUILDER TO �-- -------I r _ 4' -0" 12'-1" W.H. PROVIDE APPLIANCE PROTECTION 2 #5 REBAR () .. I � 1 " 0 -0 I � � : ' I REQUIRED I VERTICALS w/ in ■ : I : EREN FILLED CELL I , FBC 35`-4" �1 20'-6" 3-1/2" MIN 3000 PSI CONC. .� I SLAB FOR HERNANDO I M I (: • K - I J v COUNTY ONLY r S3 I S3 CONC SLAB OVER 6 MILSV SQ EEN 2'4j4" 4�-Oj" V-61" I I VAPOR BARRIER .. ' ■ ' -GJ .. - CJ iO rn — — — •� — — — �: ' — — — t4 — — — r r Cl) • n 1 n 1 n aD r V-3 1-10 3 -6 *; I 0 = 00 I I PT. OPT. D I ; -3 1/2" c _ ._ ' o 2'-6"x2'-6"X1'-0" FTG G ' : I : W/ (3) #5 E.W. S3 T-5" SLOPE 7 (2) #5 REBAR 2'-6" x 2'-6" x 1'-0" H ARTICALS I I I VE w/ in W/ (3) #5'S E.W. TYP @ 1 STORY U.N.O. `� K CC I S3 S3 FILLED CELL I °° 1 r S3 -41 I —ICJ = I/CiJ - - '_''�'_'_'_'%.. '. _ .... . ... ...._.` 25'-10 9- " : 4'4' v B0 I 1_ fl 1 " 1_ N 2 6 x2 -6 Xi 0 FTG = W/ (3) #5 E.W. I INDICATES FILLED CELL w/ 3000 PSI I i I PROVIDE Yz" x 9" 'r' CONC. GROUT FROM FT. TOBEAMRECESS FOR FRT. OOR W/ (1) #5 REBAR VERT ABOVE SLAB SLOPE I S3 o U) 4 0 1 " 4'-4" 4'-6" I TYP @ ALL PLACES SHOWN II HVAC CHASE TOP OF CONCJ PAVER T BE 4' ' BASED ON 0'-0" . ■ HOOKED FTG. DOWELS 5" EMABED BELOW FIN. FLR. ■ ......... ........... ■ W/ 25" EXT. ABOVE SLAB "GF ADE 40 i i LOCATION I ..:::::::::::::::::::::::::::::::: :::::::::::: ' ' ' STEEL" .:::::::...: • L _ .......� I 16'-10" i • c 4 4'-0' I r 1 :12':10" rn STEPS AS ........ ; PROVIDE 1 Y2" RECESS • • 101.1 �„ REQUIRED PER FIELD CONDITIONS FOR SGD. REFER TO I KITCHEN ISLAND • • MASON'S SLOPE FOR OPT. " """"""""" ' "•' ' LOW WALLS WIDTH � ------1 a ' '•' " ' .. A.■: r------ c REF.:.-I-rv.l Cl: CJ�I •■ — - - = -_'" -��- - - - - - - - r- - - - I I - - - - ° TYP @ 1 / IF- I CHASE TO ISLAND :: I D.W. I ::..o...... t I I I lit STORY U.N.O. A N o _ LL - II O0 S3 rr 'n _ -_____-- SINK /DISP t M I-31 /2" :: I I t 1 1, 0 _0 16'-0" 21_ 11 V-10" .... • ■ ��: r I / v •• :: M :. I =O f. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TYP @ 1 STORY H.B. U.N.O. A S3 64" L 11_98„ L 31_211, L 5'-0" L 5'-0" L V-10" 2'-1Od-" L V-11 41' L 5'-01, L 5-4- FOUNDATION PLAN SCALE: %4'=1'-0" NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "E" OF THE FBC 5th EDITION (2014) BUILDING IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING W.W.M. PLACED IN 1/8" SAWCUT x 1/4 SLAB UPPER 1/3 OF SLAB THICKNESS WHERE OR FIBERMESH SHOWN ON REINF. SEE PLAN. FOUNDATION PLAN LU w co CONTROL JOINT DETAIL SCALE: 11/2 4-0" .• • • • .� #5 CONT REINF. SEE . , '•, FND. FOR QUANTITY #5 X 25" X 25" CORNER ' ' �'• ' ' �' ' '' ' BAR ONE FOR EA. ' HORIZ. REBAR, TYP. .... ..:. U.N.O. • • • **Alternate: The reinf. bars shall be _ ;;;••;;: ;;: �:%.; cont. around comer by cold ,; ••;;: ,; , ,; • ••�:= bending the bar w/ min. bar lap of 25". TYP. CORNER BAR DTL. SCALE: 1 1/2"=V-0" 0 Z o - CD Z N Z Q v) Z Ln (.D W cn 4--) W f) U - w °� = 0 o 0 (a U �M W �- E -00 C M co T M M Ooaimo = N I U L tL CO �� �o Q rn Q o p N Z1P1 z°$ON .. .LLq• `o,. "' i w0 -.0- AD on@oaf �p ,`,,� i. r't To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z C) _N n I•> -I tl M O M QU)CID Ln QL_ LL Ln M fu U a00 Q E z J CD W 35� � zn a fFM �i�oa z � cy.,U � Z uZJ. CL IDYfW ��o J 1-1 O 88 L r O �- Q Z Z s Z � 3 M �o o 0 O = �\ ( J ¢J ¢ Uj d x Z W Q Oii' p Z ��serQ— F O �•+� xx O U N 0 ¢ Q Z Z LU rl U')W aWo �o� J rl LJ.J I¢- u o SQa Q Z F O~ ¢LUz Z U J o g = <z Uj a SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 10 SHEET NO. 6.0 UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. 0 CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF 5YP SPF A HETA20 1810 9 -10d x 1 1/2" HTA20 1615 1585 10 -10d x 1 1/2" B HETA16 1810 9 -10d x 1 1/2" HTA16 1615 1585 10 -10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8 - 8d R73 610 525 8 - 8d X 1 1/2" E META20 1450 7 -10d x 1 1/2" HTA20-18 1400 1400 10 -10d X 1 1/2" F HHETA20 2235 10 -10d x 1 1/2" G H10A 1340 1015 18 -10d x 1 1/2" RT16A 1380 1160 9-1Od X 1 1/2% 8-1Od H HTT4 3610 3105 5/8" ANCH. / 18 10dxl-1/2 HTT4 2715 5/8" ANCH. / 20 10dxl-1/2 J HTT5 1 4350 3740 5/8" ANCH. / 26 10dx1-1/2" HTT5 3225 5/8" ANCH. /(28)10dxl-1/2 K 30 5/8"DIA. BOLTS TDX2-TZ 2345 — 2 - 5/8" DIA. BOLTS L H B * 4505 37 5/8" ANCH. 3/4" STUD BOLTS TDX6 5320 — 2 - 7/8" DIA. BOLTS M HD7B * 6645 56 7/8" ANCH. 3/4" STUD BOLTS TDX10 7845 — 4 - 7/8" DIA. BOLTS N 1165/1070 ** 1005/915 ** 8 -1 Od x 3" JUS26 1115/1060** — 8 -10d P HUS26 1550/3335 ** 1335/2820 ** 20 -16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" 0 HUS28 2000/4220 * 1720/3125 ** 30 -16d x 3 1/2" HUS28 2570/4345 — 30d -16d x 3-1/2" R MTS12 1000 860 14 -10d x 1 1/2" MTW12 1 1195 1005 14-10d x 1-1/2" S MTS16 1000 860 14 -10d x 1 1/2" MTW16 1195 1005 14-10d x 1-1/2" T MTS20 1000 860 14 -10d x 1 1/2" MTW20 1195 1005 14-10d x 1-1/2" U MGT/MUGT 3140 3140 22 -10d X 1 5/8" ATR W/ 5" EMBED W/ SIMPSON "SET" EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4" x 2-1/4" TITENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4" x 3" WEDGE BOLTS HTS 20 1450 1245 24-10d X 1 1/2" HTW20 1530 1285 24-10d X 1 1/2" SP1 585 535 10 -10d SPT22 685 8 - 10d SP2 1065 605 12 -10d SPT24 1030 12 - 10d 645 555 12-1 Old X 1 1/2" * MINIMUM 3" MEMBER ** REACTIONS ARE FOR ROOF LOADS ONLY *** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT RECI'D ON ROOF PITCHES 3/12 & LOWER. LOADS - ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL 2-0-0 MMIUM SPACING ON VERTICALS OF (B) TRUSS ++) (B) B) (A) (+) 1 OR 2 PLY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6') *FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (-). (B INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 y �y Cp�R�E —�A) 2 z INTERSECTIONS. SPLICING / CONT LEDGER TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. ROOF FRAMING PLANT SCALE: %4'=1'-0" I 0 Z o Z Q IZ Z V) 0 Q) C (DIM 4--J w U — w O ~ 0 co r- U 3 w 1— E 0 0M Cl) C t6 M 2Mco N — O oo L LL 00 O 2fY u7 OT Qo rn rnQo BD® �� ��� d' 2*W Zu . I Nam. ,{ `• � W ,f� cc LL LU �' U'Enz�k�sl)1,0100 O To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. Z (y O au r-, F�1 :Lj p �>-+HMO M a U-) IZ � Ln C) Q " U- C" � M � U CL a �00 § (v Z J W � d' oZ z, w Za f¢ �F Z Q " 480 U (LwQ OwZ J d � W Y Fm-0 NW Z O V > v' Q 2:Z g LL C3 D M o :T� ' O O o Z V R� LL Li/ o Q°o O VY � oOS O c a W z J W C Z Q �o Q z d- =)�o Z -j In di CY "o�Z Iwo Q z 8 Y Q w 9 F 0 Z tu uj Z C Cy V) � 4 T Z ¢ z ISLU J 1 SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION NO. 10 SHEET NO. 7.0 IF111-1 hII INI!tl�JF.Ii JIL II ik4. �,n :h4.1d:ti ill ill ijai Il I,: II I I II GENERAL INSTALLATION NOTES 1. Provide full mortar head and bed joints. 2. Shore filled lintels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate vertical cell reinforcing and grouting. 5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and longer with a nominal height of 8" meet or exceed L/180. 6. Bottom field added rebar to be located at the bottom of the lintel cavity. 7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. 8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete masonry units. 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. 11. The exterior surface of lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) loads shoud be checked for combine loading with the following equation: Applied vertical load Applied horizontal load <1 " 0 Safe vertical Ioad + Safe horizontal load _ GENERAL CONCRETE LINTEL SCHEDULE o •�•o o, •o 8F8-1B/1T 8F8-0B/1T APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY 8RF6-0B/1T © O O O O O O o O 8RF14-1B/1T8RF14-0B/1T 8F16-0B/1T 8F16-1B/1T © 0 8F44 1 B/1 T 8F40 1 B/1 T 8RF400B/1T 81`321B/1T F = FILLED WITH GROUT / U = UNFILLED R = RECESSED QTY. OF #5 REBAR @ BOTTOM OF LINTEL CAVITY 8 F 16— B/ 1 T a 110 tNOMINAL. QUANTITY OF WIDTH #5 REBAR AT TOP NOMINAL — HEIGHT MATERIALS TPc prate Ynteis = 3500 psi. 2. fc prestressed lintels = 6000 pal. 3. grouted per ASTM C476 fg = 3000 psi w/ 4. maximum 3V aggregate and 8" to 11" slump. 5. Concrete masonry units (CMU) per ASTM C90 w/ minimum net area compressive strength =1900 psi. 6. Reber per ASTM A615 Grade 60. Prestressing strand per ASTM A416 grade 7. 270 low relaxation. 7132 wire per ASTM A510. 8. Mortar per ASTM C270 type M or S. 8F24-1B/1T O #S REBAR AT REQ'D ALTERNATE POWERS M IN. (1) CAE R STEEL LINTEL 0 a e a ° .M.U. #5 REBAR AT TOP n ° , MIN. (1) REO'D ° 4 1-1/2" CLEAR GROUT ,d e J = Q L � A —46 REBAR AT N = N (- W 4 ' 4 O BOTTOM OF a co z W ui W LINTEL CAVITY OTTOM uu 0 co p Q o Q REINFORCING PROVIDED IN LINTEL Ir �j Q CJ LL ri w ,n Zd •' i7 3 D f "ACTUAL NAL WIDTH � a �o <10 (VARIES) CLUE c~iu � LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) 16 GAUGE POWERS STEEL BOXED LINTEL POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF NOTED ON LINTEL PLAN 1. Refer to manufacturers specifications for installation. 2. Contractor to provide proper protection of lintel to prevent rusting. Refer to manufacturers specifications. 3. If lintel Is scratched or damaged refer to Powers Steel for repair. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel plan/details for bottom steel required. 5. A bonding agent must be applied to the Steel Box lintels prior to applying the cementitluos coating. See contractor specifications O O 4'-6" LL 4'-6" LL O 6-10" LL LINTEL PLAN SCALE: %4"=V-13rr 0 Z Mo Z (0 Z Q J Z U) Ln CD n W N 4}J w U O w � m ~ 0 = �co V) f— o0 m r U w 4)M C r 0 co t— p U MIN NMM 0 O O (U (D L LL c() 7 U0) 4 U)ao O V' .Ltir•' Q 0) Q O A B ' D. N C,B,D C i ~ ��� f e 4 : i co C) c oa O ..M Z LL LL NM W`��RV _ ti�• > O W.'Ij� g ZQC 0IJ fox o fN U UTo the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z cV 0 a) r> U-) M Q U) f0 Ln a cn•�� Ln Q LL F� Q E170 � Z J W 0, w � z¢a ¢f fF Zim gOWO �DzZ w �005, JJ F�O L OZ O z M V)� 0 _V J� 2fu a J LU W s fLOo F 0$ .; F— fV p�o ` J 0 J a Q j Z Z rl a LL ;orr J di Fzo U Q z Lu Q W Z 1,0 Z Z Z3 o Ow ^ g LU = 0 a rn rn a V SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 10 SHEET NO. 8.0 NOTE: BORATE/ SENTRA CON SYSTEM APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS AS OF DECEMBER 31 T S , 2003, CHROMATED COPPER ARSENATE (CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL EV RAL NEW PRESSURE TREAT ED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRES SURE TREATED WOODS USE CHEMICALS I ALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACO-D, CBA-A, OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS (RE: FRC R308.4) R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY II AS INDICATED IN TABLE R308.3 EXCEPTIONS: 1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR. 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7. 3. GLAZING IN SECTION R308.4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 4. GLAZING IN SECTION R 308.4, ITEM 6, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION OR WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 7. 5. GLAZING IN SECTION R308.4, ITEMS 7 AND 10, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES t 2 INCHES (914 f MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 Yz INCHES (38 MM) IN HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL [WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR. 7. LOWERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308.2. 8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 9. SAFETY GLAZING IN SECTION R308.4, ITEMS 10 AND 11 IS NOT REQUIRED WHERE: 9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF SECTION 1012 AND 1607.7 OF THE FLORIDA BUILDING CODE, BUILDING; AND 9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. 1. SPECIFICATIONS 1.1. CONSTRUCTION: 1.1.1. ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.1.2. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1-11, ASCE 6lTMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.1.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.1.5. FLORIDA RESIDENTIAL CODE (FRC), FLORIDA BUILDING CODE (FBC) 5th ad. (2014) 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC)13TH EDITION. 1. 1.7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TRI1-02. 1.2. DESIGN: 1.2.1. ACI 301-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1-11, ASCE 6/7MS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1.2.6. FLORIDA BUILDING CODE (FBC) 5th ad. (2014) AND FLORIDA BUILDING CODE 5th ad. RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS: 1.3.1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 1.3.2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA. REG. PE. AND SHALL INCLUDE: DRAWINGS AND CALCULATIONS REACTIONS AND BEARING POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS: 2.1.1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 2.1.2. UNIT WEIGHT OF REINFORCED CONCRETE: 150 PCF 2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: 55 PSF 2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2.1.7. BALCONIES & DECKS: 15 PSF 2.1.8. TILE ROOF TOP CHORD : 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOP CHORD : 7 PSF BOTTOM CHORD: 10 PSF 2.1.10. FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1. SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2. GARAGE LOADS : 40 PSF 2.2.3. PARTITIONED ROOMS: 40 PSF 2.2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS: 40 PSF 2.2.6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2.8. ROOF TRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE) : 10 PSF (NON -CONCURRENT) BOTTOM CHORD (ATTIC W/ LIMITED STORAGE) : 20 PSF 2.3. RAILING LOADS: 2.3.1. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SO. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3.1., 2.3.2 & 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FBC 5th ad. (2014), AND CONDUCTED BASED ON A140 MPH 3 SECOND GUST, EXPOSURE "C", IMPORTANCE FACTOR "I" =1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS -10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE 7-10 2.5. DEFLECTIONS: 2.6.1. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240 TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1, LOAD FACTOR DESIGN: THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2. SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DL + FLOOR LL + ROOF LL TOTAL DL + FLOOR LL + WL TOTAL DL + WL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. 3.4. DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS, 4. MATERIALS 4.1. REINFORCING STEEL: 4.1.1. REINFORCING STEEL SHALL BE ASTM A615 / A185M-04A MIN. GRADE 40, fy = 40 Ksi 4.1.2. LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4.1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4.1.5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4.1.6. DESIGN COVER REQUIREMENTS: C-I-P CONCRETE FORMED AGAINST EARTH: 3" C-I-P CONCRETE EXPOSED TO EXTERIOR: 211 C-1-P CONCRETE NOT EXPOSED: 1 �" GROUT FILLED MASONRY: 3/a„ 4. 1. 7. WELDED WIRE FABRIC (WWF): ASTM A-185 / A 185M-07 4.1.8. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-11 (STRUCTURAL CONCRETE) ACI 530-11 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1. CONCRETE TYPE MIN. 28 DAY DESIGN (fc) MODULES OF ELASTICITY DESIGN (E) C-I-P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-1-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ksi C-I-P GROUT 3,000 Psi 3,122 Ksi 4,2.2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT, SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS) : 31/2" MIN. THICKNESS W1 MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.2.7. CONCRETE PLACEMENT PRACTICES SHALL BE IN ACCORDANCE W/ ALL ACI- MCP 2011 STANDARDS. 4.3. CONCRETE MASONRY: 4.3.1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-0601, TYPE 11 NON -MOISTURE CONTROLLED. 4.3. 3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL STEM WALLS. 4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm =1,500 PSI MINIMUM. 4.3.5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.3.6. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. 4.4. STRUCTURAL LUMBER: 4.4.1.1. INTERIOR LOAD BEARING WALLS SPF #2, fb =1,312 PSI, E =1,400 KSI ALL EXTERIOR FRAMING SPF #2, fb =1,312 PSI, E =1,400 KSI 4.4. 1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4.4.2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15132" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. 4.4.3. ALL PLYWOOD FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND 0 USED SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES. 4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4.6. WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSI/TPI 1-2007, BCSI 4.4.8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8" STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK 4.4.10. INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R706.6.1 4.5. FASTENERS AND TIE DOWNS: 4.5.1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTM A36/36M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTM A307 4.5.2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33Ks1WITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. 4.5.3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0.131", 10d = 0.148",12d = 0.148", 16d = 0.162". 4.5.4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION. 4.5.5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4.5.6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4.5.7. CONCRETE EMBEDDED'J' BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. 4.5.8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.6. MICRO -LAM LUMBER: 4.6.1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E = 2,000,000 PSI Fb = 2,950 PSI Ft= 1,850PSI Fc= 500 PSI (PERPENDICULAR) Fc = 2,700 (PARALLEL) 4.7. STEEL: Fv= 285PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEEL ERECTOR. 4.7.2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4.7.3. STRUCTURAL STEEL: ASTM A36/36M 05. 4.7.4. STEEL TUBING: ASTM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3116", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL: ELEMENTS ARE IN PLACE. 4.8.1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF 4.8.2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FBC 5th ad. (2014), RESIDENTIAL SECTION R318. 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02E01 TERMITE PROTECTION - CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate / Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1. FRC R318.1- "A permanent sign which identifies the termite treatment provider and need for re -inspection a iMireatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel" 2. Condensate and roof downspouts shall discharge at least V-0" away from the building side walls. 3. Irrigation/sprinkler systems including all risers and spray heads shall not be installed within 1'-0" cf the building side wall. 4. FRC R318.7- To provide for inspection for termite Infestation, between wall covering and final earth grade shall not be less than 6 inches. Exception: Paint or decorative cementitious finish less than 5/8" thick adhered directly to the foundation wall. 5. FRC R3181.1- Initial treatment shall be done after all excavation and backfllf is complete. 6. FRC R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FRC R318.1.3 - Boxed areas in concrete floors for subsequent installation of traps etc., shall be made with permanent metal or plastic forms. Permanent forms must be of a size and depth that will eliminate the disturbance of soil after the initial treatment. 8. FRC R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilutipn. If rain 11 occurs before vapor retarder placement, retreatment is requr 9. FRC R318.1.5 -;C nWte ov re our Ind mortar along the foundation perimeter must be remov re e or so treatment. 10. FRC R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0" of the structure sidewalls. 11. FRC R318.1.6 - An exterior vertical chemical barrier must be installed after construction is complete, including landscaping and irrigation. Any soil disturbed after the vertical barrier is applied, shall be retreated, 12. FRC R318.1 - All buildings are required to have pre -construction treatment. 13. FRC R318.1- A certificate of compliance must be issued to the building department by a licensed pest control company before a certificate of occupancy will be issued. The certificate of compliance shall state: "The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FRC R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-0" of the building. This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. WORST CASE DESIGN PRESSURE TABLE BUILDING DATA WIND SPEED (ULTIMATE) 140 MPH WIND SPEED (ALLOWABLE) 108 MPH WIND EXPOSURE - "C" (FRC R301) INTERNAL PRESSURE COEFFICIENT= 0.18 ENCLOSED BLDG) BUILDING CATEGORY = II DESIGN WIND PRESSURE: (COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) # END ZONE IS ONLY WITHIN 6-0" OF ALL EXTERIOR BUILDING CORNERS WINDOWS AND DOORS 140 MPH + 29.7 PSF / -39.6 PSF (END) U.N.O. + 29.7 PSF / -32.2 PSF (INTERIOR) U.N.O. CONSTRUCTION GARAGE DOORS N =140 MPH) TYPE: 5B SINGLE 90 +26.3 PSF / -29.8 PSF DOUBLE 160 +25.2 PSF / -28.1 PSF NOTE: THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES. NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1%" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1" DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBAORD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW / NAIL DISTANCEFROM EDGE SHALL BE %". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. Loin Z co O -0 z Z Q J d Z V) 0 va w •U - m w 0 ~ 0 o 0 U N Ll r E U cNo C f0 Cl) @ N O o0 U O LLCO OYr- Y O m t1J O rn Q O A1 N C-BBD-C ,a .0 F'- ` N c(N' p"pNp' z m m Z X - J O s� O LLIt J Zi 'a C it M �y{ oil- PF- lum�SS J `V� To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O oN Z 0 r > Ln O M Q U-) -gyp Lf) d- a to •,_ C LL Ln d 0Y U ra 00 CL 00 Q 3i ro Z J W C) d- 3� W� z Qa f¢ 0 �o�0 �LLI zzz 06'2J o Couuj�N 0 i W ;o I- z z M Q J f zo J 085 ma N -� W<Z� < Q Z ^ Q--. mt2 Z LU Ln w zoo i5 LL 0 J diQzo U L Q Z ¢ 8 z Z Z cy� a Z m � g W = �o az dUj SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION NO' 10 SHEET NO. SN II IT -T-F TIFF 1 i�a 1, Bil CORNER OF HOME GARAGE SIDE J ROOF DIAPHRAGM NAILING SCHEDULE RIDGE LINE/01 +/ + 15/32" CDX PLYWOOD OR c3 7/16" OSB IDGE LINE 140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE + + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER 16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH 0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER 2 INCH NAIL LENGTH 2 INCH NAIL LENGTH NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED 1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. 2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. 3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 6'-0" + 6'-0" +++ +++ + + + + + + + + +++ +++ ++ +++ ++++++++ + Backer and Filler Block Dimensions BCI®Joist Backer Block Thickness Filler Block Thickness Series 3/4" or 7/el 5000s 1.8/1.7 wood panels Two 3/4" wood panels or 2 x — 1-1/8" or two 1/2" 6000s 1.8/1.7 wood panels 2 x — + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 6500s 1.8/1.7 wood panels 2 x — + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 602.0 wood panels 2x — + 5/8" or 3/4" wood panel 902.0 2 x — lumber Double 2 x — lumber DOUBLE JOIST CONSTRUCTION (Not required if both loaded equally from above) Filler blocking 1/8" gap / + y FILL CELL—N ,— STD. 90° HOOK BOND BEAM w a STD.90° CONT. #5 OOC CONT. #5 HOOK BAR BAR #5 CONT. . ........7t., FROM NDATION TOHIGHEST BOND BEAM BOND BEAM STEP SCALE: N.T.S. 2nd FLOOR INTERIOR/EXT WALL SEE PLAN FOR MORE INFO CONT. BASE PLATE BEARING COLUMN PLYWOOD FLOOR SEE PLAN FOR REQ'D SHEATHING PER PLAN COLUMN AND CONNECTION TJI TO BE CUT TO ALLOW FOR BLOCKING/TJI MASONRY WALL OR INTERIOR BRG. WALL TJI PER PLAN OTHERWISE SOLID BLOCKING TO MATCH # OF 2nd FLOOR Solid block all posts from STUDS above to bearing below. SECTION @ INT. BRG. WALL N.T.S. 1/8" min. Small 2� min. } gap max. � 4 max. 4 Clinch nails when possible ) 1) Support back of web during nailing to prevent damage to web -flange connection. 2) Block solid between joists for full length of span. Tight fit 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. 4) Place joists together and nail from each side with 2 rows of 10d nails 4" max. 2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or OF THE JOIST ASA REQUIRED LEAVING y" GAP TOP sides b 6". - Hangers with side nailing. @ Y- Hpngerswithsidesnotcontaining t. WEB STIFFENER DOUBLE JOIST CONNECTION Birdsm uthce of uis. - Birdsmouth cuts. N.T.S. - Under 2nd floor column w/ loads N.T.S. SQUASH BLOCKS AT INTERIOR BEARING Vertical load transfer =1900 plf max along load bearing wall. Load bearing wall must stack over squash=20 blocks and Non -stacking walls require additional wall or beam below consideration. Check local building code for appropriate details in One 10d box areas=20 of high or-20 sinker lateral load. nail each side 10'-0" at bearing. TANK -LESS W/H H C G O O O 5'-0" STUB -OUT FOR O o GAS METER 0 0 F CV = • MEASUREMENTS ARE FROM FINISHED FLOOR • ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER • ROUGH -IN ELECTRIC TO LEFT (ALWAYS) -12" OFF -CENTER GAS CONNECTION DETAIL **ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4" @ 16" O.C. 7'-5" (2)16d TOENAILS 2" X 6" @ 16" O.C. 10'-8" (2)16d TOENAILS 2" X 8" @ 16" O.C. 13'-9" (3)16d TOENAILS 2" X 10" 16" O.C. 16'-5" (1 USP HTW20 OR 3)16d TOENAILS 2" X 12" @ 16" O.C. 19'-3" (1) USP HTW20 OR (4)16d TOENAILS 2" X 4" @ 24" O.C. 6'-1" (2) 16d TOENAILS 2" X 6" @ 24" O.C. 81-6" (2)16d TOENAILS 2" X 8" @ 24" O.C. 11'-0" (2)16d TOENAILS 2" X 10" @ 24" O.C. 13'-0" (3)16d TOENAILS 2" X 12" @ 24" O.C. 15'-4" (1) USP HTW20 OR (3)16d TOENAILS * TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). ** SOUTHERN YELLOW PINE, 55 PSF LOADING Squash block (2x4 minimum) Bearing wall, Versa -Lam LVL or Glulam Beam 0 Boise Joist Blocking Lisa 3" /10d1 nails at 6" o_c_ Provide adequate bearing for each lapped joist. nails SECTION @ INT. BRG. WALL N.T.S. NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE IN BEARING ZONES D (KNOCKOUT EXEMPTS) (see table below) D to (see table below) DO NOT cut, notch or drill flanges Web Stiffener Fastener Schedule Joist Bearin Location Series Depth End Intermediate ® BCI5000s 9-1/2" 11-7/8" 2-8d 2-8d 2-8d 3-8d 14" 2-8d BCI 6000s® BC16500s® 9-1/2" 11-7/8" 2-8d 2-8d 2-8d 3-8 14" 2-8d 5-8d 16" 2-8d 6-8d BCI60s® 11-7/8" 2-8d 3-8d 14" 2-8d 5-8d 16" 2-8d 6-8d BCI90s® 11-7/8" 3-16d 3-16d 14" 5-16d 5-16d 16" 6-16d 6-16d higher than 15001b. BLOCKING PANEL, INTERIOR Vertical load transfer =1900 plf max. along bearing wall Required on interior walls : - for vertical load transfer Plumbing when load bearing - for lateral support when joists meet over wall, or wall stacks directly over wall or beam below Load bearing wall must stack over blocking and wall or beam below.* C L Joist When joists meet over wall, provide 13/4" minimum bearing for each. I -Joist can be offset up to 3" to avoid vertical plumbing 3" max JOISTS OFFSET N.T.S. Use 10dx3" nails at 6"o.c. for all joist blocking panel *Non -stacking walls require additional consideration. — 6„ A 1 2' ROUND HOLE MAY 6„ 6„ DO NOT CUT HOLES BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1y" THE WEB, PROVIDE AT ROUND IN LEAST 3" OF CLEARANCE CANTILEVERS. FROM OTHER HOLES MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" 8 1' O" 1'-1 " t -Z' t -2- 1-37 '1'-3° V- " 1!-11" 2-4' 2�° 3. Z" 3 T' Any 16' joist _ 12 11-al 1 _1,. 1 2. V—z' 1,_3. 1'-'° 2'-4' 2-i%" 3'-7" 4' 7° 4-9 9-41 16 T_a, 1-1 ' T 2a" 1' z" 1-7"' -5' 3'- ' 3'-10 " 4'-,�" ice'° S'-4' T-Z' 20 1' {i' T-1' T-2" 1' -° 2-0'" 34Y' 4'-- Y' 4'-10" 6-11'" 6-11" 7'-'11.' S'-11°" 24 14Y' 1,_1,° 1'-2'° 1',3,. 2�'" 3�-7"' 4�-9"° 9-10," 7'-2" 8'-,4"' 9-0'° 10'-9' NOTES: 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1V KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE, HOLE CUTTING CHART N.T.S. Joist hanger USP MU( 5/8"a THRU BOLT UI Mt R TRUSS 'OP PLATE I.0 TYPICAL USP MUGT15 TO BUILT-UP COLUMN DETAIL TYPICAL HUS INSTALLATION AIN. EMBEDMENT SCHEDULE FOR AND QUANTITY W FASTENERS TYPICAL HTA 20-18 / HTA 20 INSTALLATION A/C CHASE 4" PVC SLEEVE THRU STEM WALL Backer block (12" wide min.) — Nail with 10-10d nails. — — Install tight to top flange. SLEEVE THRU STEM •. •. SEE PLAN FOR •• a . • '.; . FOUNDATION INFO STEM FOUNDATION \ Filler block. Nail with 10-10d nails. Backer block required where top mount hanger load exceeds 250 lbs. Install tight to top flange. VBackerBlock -2" gap " 'Top Mount Face Mount' Backer block shall be tight Backer block shall be tight to bottom of top flange with to top of bottom flange with 1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top flange. flange. eb stiffner as Web stiffeners are not required when top required if hanger flange is laterally supported by joist hanger. doesn't meet height requirements 0.6 X Joist depth I -JOISTS BUCKETS N.T.S. GRADE REINF. SEE PLAN n A li II-- II-14 a = A/C CHASE 4" PVC (2) #5 REBAR SLEEVE THRU FOOTING MONO FOUNDATION TYP. FND. PENETRATIONS SCALE: N.T.S. HTA 20-18 / HTA 20 INSTALLATION @ MID SPAN LOCATION OF SECOND RT16 0 NOTE: UPLIFT VALUE IS BASED ON S.P.F. USP RT16 USING 16-8d x1 1/2" NAILS UPLIFT =1030# TYPICAL RT16 INSTALLATION TYPICAL MTW INSTALLATION TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION 12" BELOW GRADE PLUMBING LINE PVC OR SCH40 SLEEVE 4. 4: ° .e i I — I' SEE FND. PLN. SIZE & REINF. PIPE VERTICAL THRU FND. TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE CENETERED @ PIPE//_ PENETRATION PLUMBING LINE A41 iozl •�• • � e SEE FND. PLN. SIZE & REINF. PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4' _0" PVC OR SCH40 SLEEVE CENETERED @ PIPE PENETRATION PLUMBING LINE d TO a°'/.— .. ....nG' a a - d' a f ° SEE FND. PLN. SIZE & REINF. 0 Z� 0 — o Z N zCN Q lL (D Z 4-J w w 0 ~ o o0 `� ~ m� U �.� W H — 8 0M M c l0 co N 9 cM O o0 _ " o000 Ua) = y inao O tt Q 3)Q o A1 B D• N-C--B D C a�a r• .- • �` ��° • 0 �&9_N V N r rii co 0 2-1 � r ¢�, �,ap- ilY ���LL W° 0��• JW?•• m �" VA � S`O tJIiJ3,%\\ 0 O ❑❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 1f O Z N 0 .N N >�Mo M QLn Ln -0 a (A L L_ L a Fes- 113�a V170 '--' z � z Z � WJ C) W� z¢a f¢ U � U Lu Z Z $�Uo W oz ZU > zz n3 C M Q 0 UV "Q -a I C:J Q = (u U f o� �R0 Y O X U N U) =way QQ3 F;oWce ?ego Z Z W Ln di a i Q o = J rl 111 a z Q Z 8 s;� r Qz gO m O � Z _ ¢Z rn ,--I a to I III SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 10 SHEEP NO. SN 1 FOR UNDERLAYMENT REQUIREMENTS SEE R905. (TYP') VARIES / 5/8" OR 1/2" HIGHS STRENGTH CEILING BOARD PER CODE (OR 5/8" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM ABOVE) W/DRYWALL SCREWS @ 7" O.C. CEILING & 8" O.C. WALLS INSULATION PER CHART ON FLOOR PLAN 1x2 P.T. HORIZONTAL NAILER STD. 90-HOOK (SEE DETAIL (1) LAYER TYPE II (#30) UNDERLAYMENT FOR ROOF PITCH >4:12 (2) LAYERS TYPE I OR TYPE II (#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. PRE ENGINEERED WOOD TRUSS @ 24" O.C. U.N.O. HURRICANE ANCHOR @ EACH TRUSS (SEE UPLIFT SCHED.) W/ METAL PL. UNDER EA. TRUSS MOISTURE BARRIER SHINGLE ROOF 7/16" O.S.B. MIN. SEE ROOF NAILING SCHEDULE ON SHT. SN1 ELEV. VARIES -ALUMINUM DRIP EDGE -ALUMINUM FASCIA -2x SUB FASCIA -SEE SOFFIT SHEET 8"x8"X16" KNOCK -OUT BLOCK W/ 1#5 CONT. FILLED SOLID W/GROUT -8" C.M.U. TYPICAL TYPE "S" MORTAR ARCHITECTURAL FINISH 1x2 PT WD FURRING @ 24" O.C. 1/2" GYPSUM WALLBOARD (1) #5 VERT. IN FILL U.N.O. CELLS (SEE FOUNDATION PLAN FOR LOCATIONS) 1x4 P.T. BASE NAILER 4"x4" INSPECTION 31/4" BASEBOARD PORT AT EACH FILLED CELL TYPICAL MIN. 2500 PSI CONC. SLAB cr) AT GARAGE CONTRACTOR MIN PSI MAY VARY PER TO CUT BLOCK OR POUR MUNICIPALITY. CURB DUE TO SLOPE CONCRETE SLAB W/ 6X6 n- NOTE:EXTEND W1.4XW1.4 WWF OR "FIBERMESH" DECO FINISH 4" to 6" BELOW GRADE E � � N ' r ° 00 c� EMI D C 6 MIL VAPOR D = z_ BARRIER _ c • — T COMP. SOIL. e (COMPACTED TO 95% — — MODIFIED PROCTOR I I ASTM D1557) 3" MIN. CLR. (2) #5 REBAR CONT. ON 3" CHAIRS TYP. 4" 1'-4" STD. 90 NOOK (SEE U.N.O. DETAIL) TYPICAL WALL SECTION rA SCALE: 3/4" =1'-0" S3 OPT: DEPRESS SLAB 5 Y2" DEEP AND 6" BEYOND DOOR TO RECEIVE PAVERS / DRIVEWAY BLOCK WALL BEYOND CONCRETE SLAB PAVERS �j /-O.H.D. RECESS SEE A/S3 OR J/S6 —� _I I m1Tn LT T FOR REINF. INFO. 3" MIN. CLEARANCE 1'4" (1 STOR) I / 1'-8" (1 STORY W/ DEPRESSED SLAB OPT.) 1' 8" (2 STOR GARAGE DOOR SLAB RECESS J.1 SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. 2x #2 SPF STUDS - @16" O.C. W/ (2) 16d TOENAILS T & B 2x P.T. PLATE --\ (2) #5 CONT. ON 3" CHAIRS (TYP.) (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. s V-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z APPLICABLE. 1/4" DIA. X 31/4" TAPCONS @ 24" O/C & @ 6" MAX FROM END OF 2 x PLATE 6x6W1.4xW1.4 WWF OR FIBERMESH ° I I I I r 18„ �'.._..r. TYPICAL INTERIOR BEARING WALL W/OUT UPLIFT SEE TYP. WALL SECTION SCALE: 3/4"=1'-0" FOR ADDITIONAL SLAB INFORMATION. LOAD BEARING OR EXTERIOR WALL SEE CC/S3 OR — G/S3 FOR ANCHOR BOLT INFO. (IF NO UP LIFT ON WALL SEE GG/S3) *USP SPT22 TYP. - MONO OR STEMWALL— FOOTING MONO SHOWN FOR CLARITY NOTE: *FOR BEARING WALL W/ UPLIFT ONLY GG S3 5/8"OR 1/2" HIGH STRENGTH —� (U.N.O.) (OR %" GYP. TYPE x, @ GARAGE W/A HABITABLE ROOM ABOVE) S.P.F. DOUBLE TOP PLATE 8"x8"x16" NOMINAL BLOCK WITH 3/8" MORTAR BETWEEN COURSES USP SPT24 CONNECTOR 1/2" CDX PLYWOOD OR 7/16" O.S.B. SHEATHING REQ'D. FOR ALL EXTERIOR OR SHEAR WALLS AS INDICATED ON THE PLAN. ATTACH SHEATHING W/ 8d COMMON NAILS ( 4" O.C. @ BOUNDARIES, 6" O.C. @ 3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD SLAB & BLOCK 5/8"° x 10" "J" BOLT @ 24" O.C. W/ — `_ 2"°0/16" PLATE WASHER (TYP.) \ ELEV. 0'-0" (ALT: 1/2"x12" TITEN HD @ 24" OL O.C. OR 5/8"x10' WEDGE ANCHOR p A.F.F. @ 24" O.C.) 2" a. �31/2" MIN. a p a ° Z a ELEV.-0'-31/2" a ...d a e ° p r 4 A.F.F. 0 4 2x4 CONT.BID LL I I GARAGE SLAB AT STEP SCALE: 3/4"=V-0" 2x S.P.F. STUDS @ 16" O.C. 2x STUD 8" C.M.U. 1"x P.T. STUD #5 VERT. IN FILLED CELL N 5/8"x6" "J" BOLTS BOLT @ 24" O.C. VERT. OR 5/8" x 6" EPDXY BOLT OR (6)1/4"x31/4" TAPCONS SPACED EVENLY 2x P.T. PLATE ASSUMED FINISHED GRADE FRAME WALL TO C.M.U. WALL CONNECTION SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=1'-0" SLAB INFORMATION. 6x6W1.4xW1.4 31/2" WWF OR FIBERMESH min.) 4" 11�11 11�711=11�I1�1I1: !1 . �ul�nhn�nl�u�uG--nc---ur.�u��1 MIN. TYPICAL THICKENED SLAB EDGE L SCALE:3/4"=T-0' S3 BLOCK WALL BEYOND EXPANSION JOINT 13 O.H.D. RECESS SEE A/S3 OR J/S6 J 7 11 FOR REINF. INFO. 3" MIN. CLEARANCE 1'4" (1 STC IRY) 1'-8" (2 STC RY) GARAGE DOOR SLAB RECESS SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING — NAILED W/ 8d COMMON NAILS @ 4" O/C BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. (2) ROWS OF 2x BLOCKING @ THIRD POINTS TRUSS BOTTOM CHORD OR 2x4 BLOCKING 518"OR 1/2" HIGH STRENGTH — W/ 2-16d TOE NAILS @ EACH END (U.N.O.) (OR %" GYP. TYPE X' @ SEE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) TRUSS ALIGNED WITH STUD BELOW S.P.F. DOUBLE TOP PLATE 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. USP SPT24 CONNECTOR (1) ROW 2x BLOCKING @ MID HGT, FOR WALL HGT. < V-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > V-6". INSULATION PER CHART ON FLOOR PLAN USP SPT22 CONNECTOR 5/8"° x 10" "J" BOLT @ 24" O.C. W/- 2"°x3/16" PLATE WASHER (TYP.) 2x P.T. BOTTOM PLATE (ALT:1/2"x12" TITEN HD @ 24" O.C. OR 5/8"x10' WEDGE ANCHOR 6 x 6 W1.4 x W1.4 @ 24" O.C.) WWF OR FIBERMESH 1111.11 1 71L'►,. 1 /2"(min.)- 4" U.N.O. MIN. TYPICAL BEARING WALL STEP @ SHEARWALL C SHEAR WALL 1 SCALE: 3/4 -0 S3 ��os�c J����I e0s' M�Not 2x STUDS @ 16" O/C ISULATION PER CHART ON FLOOR PLAN 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER 5/8"° x 10" "J" BOLT @ 24" O/C W/ 2"°X 3/16" METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL PLATE WASHER TYPICAL 3RD LAYER 1/8" THICK. K.O. BLOCK MIN. 2500 PSI CONCRETE SLAB W/ SP SPT22 @ EA. STUD TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ 2-16d TOE NAILS @ EACH END $EE UPLIFT SCHEDULE FOR UPLIFT CONNECTIONS. PROVIDE (1) USP HTW20 WHEN TRUSS ALIGNED WITH STUD BELOW -2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. --(1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. < V-61'. (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". INSULATION PER CHART ON FLOOR PLAN --USP SPT22 CONNECTOR /2x P.T. BOTTOM PLATE 6x6W1.4xW1.4 WWF OR FIBERMESH �31/2" MIN. ° 31/2"(min.)- 4" 00 D 31/21min.) - 4" - I I I- wl—I (2) #5 CONT. 4" "' ' I'-4 11 " "8" U.N.O. MIN. TYPICAL BEARING WALL @ STEP CC SCALE:3/4"=1'-0" S3 6 x 6 W1.4 x W1.4 WWF OR ZX P.T. PLATE 20" MIN. LAP [24" MIN. LAP] #5 REINFORCING FIBERMESH EEP SCREED INSTALLED BAR —� c PER MANUF. #3 OR #4 REINFORCING BAR #3 & #4 LAP SPLICE GRADE 40 MIN. Fy= 40ksi FINISH GRADE 60 2 [GRADE 60 MIN. Fy- 60ksi] M D. 25" MIN. LAP [30" MIN. LAP] 6 MIL VAPOR BARRIER D ° — 00 #5 REINFORCING BAR R 1 7/8" 1 a T #5 LAP SPLICE COMP. SOIL. (COMPACTED TO D • P 36" MIN. LAP [36" MIN. LAP] 95% MODIFIED PROCTOR ASTM — 10" D 1557) 11 III�I 1� I I T 4" 1'-4" #6 REINFORCING BAR #5 STD. 90 HOOK #6 LAP SPLICE TYPICAL EXTERIOR FRAME WALL FOOTING ("EREBAR DETAILS F SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=1'-0" S3 SCALE: N.T.S. S3 SLAB INFORMATION. P.T. 2x 1/2" GYP. BD. HOLD GYP. BD. 21' 1/2" FROM SLAB 0'-0" CONT. BEAD SEALANT N�� . INTERIOR d. . ' .e. � -31 d CONCRETE NAILS W 1 1/2 EMBEDMENT @ 12" O.C. STAGGERED, FROM BOTTOM PLATE TO CONCRETE " (MIN. SHEAR 180# MIN. TENSION 120#) CONCRETE SLAB go �� — — � M 6 MIL VAPOR BARRIER ' IIIi�lll��lll��ill=, 4" 4" INTERIOR WALL SLAB STEP NON-BRG. SCALE: 3/4"=V-0" —2X STUDS @ 24" O.C. U.N.O. GARAGE �2-1/2" GYPSUM WALLBOARD U.N.O. W/ DRYWALL SCREWS @ 8-O.C. —INSULATION PER CHART ON FLOOR PLAN CONT. BEAD SEALANT E 6x6W1.4xW1.4 `I WWF OR FIBERMESH r, d' n. I S3 FRAME -DOWN FALSE BEAM W/ (3) SEE PLAN 10d NAILS TO TRUSS TOP CHORD AT 24" O.C. MAX. SEE PLAN FOR /1k P.T. PLATE �ns o.s.e. COLUMN LOCATION 0'-011FIN. FLR.jk IRV z Cn W 0 w J W o W W N NOTE: SEE SECTION C/S3 FOR ADDITIONAL INFORMATION USP SPT22 CONNECTOR 2x P.T. PLATE SPACE ANCHOR BOLTS 6" MAX FROM Z END OF 2" x PLATE � D w S2 W I 'I III W11 II II D • ° (2) #5 CONT.— ON 3" CHAIRS 8" 1'-4" (TYP.) (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. s V-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF APPLICABLE. 5/8"- EXPANSION BOLT @24 " O.C. W/ 7" EMBEDMENT (MIN. SHEAR 3500#, MIN. TENSION 2600#) E 6x6W1.4xW1.4 WWF OR FIBERMESH r !;r ° . p. . • II II II II— r 8" TYPICAL INTERIOR BEARING WALL W/ UPLIFT G SCALE: 3/4"=1'-0" S3 1 1/2" RECESS FOR VA IE 6 x 6 W1.4 x W1.4 SEE ROOF PLAN S.G.D. (U.N.O.) WWF OR FIBERMESH 1; FOR TRUSS CONNECTION INFO ° & LAYOUT DESIGN SEE ROOF PLAN ;0 c '[�[ — — ° a; ° ° FOR STRUCTURAL _ BEAM SIZE & _ 41 CONNECTION INFO r� 1 J' 2x4 #2 SYP P.T. FRAMING W/ SEE A/S3/J/S6 " MIN 7/16 O.S.B. SHEATHING FOR REINF. INFO. 8 SCHEDULE ATTACHED PER NAILING OPTION #1 SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. SEE FLOOR PLAN FOR SLAB STEP &RECESS S.G.D. M /— SCALE. 3/4 -_ 1-0" S3 STRUCTURAL COLUMN SIZE & BASE CONNECTION INFO. SECURE 2x4 P.T. BTM. PLATE W/ 1/4"x3" TAPCONS AT 8" O.C. TRIM PER PLAN SQUARE CMU BLOCK BASE, SIZE VARIES PER PLAN W/ MIN. (2) #5 VERTICALS FILLED SOLID BRICK PAVERS or SLAB PER COMMUNITY SPECS MASONRY WALL AND PAD FOOTING 8" MASONRY WALL —� CONT. FOOTING STEEL- z 00 GRADE — / d a;III-1I I °. EXTEND FILL CELLS c TO FOUNDATION PAD Ev MAT REINFORCING. r ' 11 111=1 I1=1WW zo w c� 00 IM ! °a111=111 = M� I1=1 =III=III=III-III II III=III i� =III III=1 1=1I1=1 1=1 III=1 —III— DOTING0 BEYOND PAD REINFORCEMENT 3" MIN. CLEARANCE (SEE SCHEDULE) FOOTING WIDTH SEE SCHEDULE PATIO COLUMN FTG. DETAIL N SCALE: N.T.S. S3 (D�2 Z o —0 z J r� z Q) v� w U — w 0 = •14 � 0 Vi o r- ~ U mN w I-- E — $ aM co C as co f` ;a M O 6 il tU-,* 05 Y 1- a) i <.4 Q rn o L v rn o A1 B D® N C.B ,D•C 511181I/6 N 9+tq#6 .qj��. ' , N m N C �r0 g ca W+` 1.1 I' �.•. yy '��y�h. ° 0 Q+pq„�-o+°o dlN op S `0 To the best of the Engineer's knowledge`, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O ON Z 0w1-, r CD � � Q� oLn a � ,= d' L_ Ln ^ Icy- U fu zQ CO E Z WJ C) d- mi Z a Ea Cn J 'gam 80a Q L'w I— o�Z W O f J 0-0 Lo $FoL J Q zo z Icy > z M Z U-)� F o z z � g I O O1170 0 Ji �9 ' O X9 � CL N0� [� ` wza a Qow� rMn $0LLo Z z . z w J Ln LI_I Q LLj Z � E 5 ~oQ z OU . ¢ H <1 k Z Rz o g w <Ln Ln aLi SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 10 SHEET NO. S3 (MONO) (2) 2x6 OR (2) 2x8 TOP PLATE SEE PLAN (2) 2x HEADER TO SIT 2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE SEE PLAN FOR HEADER SEE PLAN FOR SIZE CONNECTION 2x DEAD WOOD @ MID POINT w/ (3)12d TONEAILS SPACED DOUBLE 2x TOP EVENLY PLATE —� 2x BLOCKING @ EACH END W/ 10d @ " O.C. FROM EACH HEADER FACE O BLOCKING (2) 2x HEADER W'VARIES PER PLAN 2xBOTTOM PLATE W/ (1)10d @ 8" O.C. TO EACH HEADER FACE 2 x 6 (MIN.) FRAME WALL HEADER DETAIL SCALE: N.T.S. 14 12 SEE TYPICAL WALL SECTION (TYpj SEE ELEV. PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2x4 SPF. #2 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT. TOP PLATE W/ (2)12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ USP SPT24 @ EA. STUD (3)10d TOENAILS T&B AS REQ'D 2x BLOCKING @ MID POINT EVERY OTHER �+ STUD W/ (3)10d NAILS CRICKET AS REQUIRED SINGLE 2x CONT. BASE PLATE W/ (2)16d TO TRUSS BELOW 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" O/C FIELD USP SPT22 @ EA. STUD 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W/ 8" EMBEDMENT 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 90^ HOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL K/S4 SEAT FOR BLOCK IS POURED, IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERALNOTES SLOPE FORWARD FOR DRAINAGE BLOCKING (TYP.) L-ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MOISTURE BARRIER SCALE: N.T.S. G—SEE PLAN FOR FOOTING DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T.S. VENT OR 2ND FLOOR 1/2" MINIMUM CEMENT FINISH TYPICAL C.M.U. WALL STANDARD 3" DIA. TEE 3/4" FURRING STRIPS THREADED 3" DIA. EXTENSION 1/2" GYPSUM BOARD SCREW OFF CAP (3- DIA.) W/ DRYWALL SCREWS FOR CLEAN -OUT @ 8" O.C. OR 4d MIN. EXTENSION FROM DRYWALL NAILS EXTERIOR FACE OF BLOCK WALL IS 1 1/2" MAXIMUM EXTENSION FROM EXTERIOR FACE OF BLOCK WALL IS 21/4" DRAIN WALL CLEAN -OUT rA SCALE: N.T.S. S4 REFER TO WINDOW PRODUCT APPROVAL SHEETS FOR INSTALLATION INFORMATION BY MANUFACTURER. TYPICAL SECTION THRU WINDOW KNOCK -OUT NOTCH LINTEL WHERE REQUIRED BLOCK Wi (1) #5 FOR CONCRETE PLACEMENT MANIM 1111111 • - .•. � � � • • �� _ . • . • • • —_ I�i! iiil�' ■■III III■■ �1i91 1911� ■■III lid■■ �Iltl IIII� ■■III I��■■ �IIII --- NOTES: Q FILL LINTEL AND ALL CELLS ABOVE LINTEL. NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. 0 VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY. Q3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. ® OPENINGS LESS THAN OR EQUAL TO 6-0" IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN. TYPICAL FILLED LINTEL ASSEMBLY SCALE: N.T.S. WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO 1/2"X91/2" PLYWOOD CREATE A SOLID BASE FOR BLOCK WALL ABOVE. SCRAP MATERIAL MOUNTING BASE SHOWN IN POSITION —2x6 MOUNTING BASE -- L G S4 J �\\NEEEE\\, �a r tJJ T O FORM CREATES CONCRETE RECESS TO 2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. KEEP STIFFENER BACK FROM SIDES ENOUGH TO ALLOW SPACE FOR FLAT MASONS TOOLS (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) GARAGE ENTRY FORM DETAIL SCALE: N.T.S. -TRACK MOUNTING BRACKET \GARAGE DOOR TRACK J(;ALt: N. I.S. a d a a BOTTOM OF MOUNTING B POURED CONCRETE BASE FOR BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED FOR GARAGE DOOR AND WATER GARAGE FLOOR. SHED FORWARD THIS DRAWING. PARTIAL INTERIOR ELEVATION SCALE: N.T.S. m 7 5/8" 8" 7 5/8" 8" 7 5/8" 8" INTERIOR WALL GL EXTERIOR WALL 1ST COARSE 2ND COARSE 3RD COARSE MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. MASONRY LAYOUT D SCALE: N.T.S. S4 SOLID AREAS ARE STEEL AND GROUT FULL 8x8x16 BLOCK DOOR OPENING -(j VERTICAL JAM 5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71 ", AND 96-3/8" ABOVE GARAGE FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) USS BOTTOM CHORD OR 2x4 TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO LBLOCKINGW/ 2-16d TOE NAILS NOT TRANSFER LOAD. EACH END ° WALL ° ad DOOR STOP w ° d ° MOLDING Q �? a � CO 2x TOP PLATE v- GARAGE 2-16d NAILS @ 24" O.C. OR DOOR EQUAL TO TRUSS BOTTOM CHORD OR BLOCKING 2 x 6 P.T. 2x STUD @ 24" O.C. MAX. ROVIDE P.A.F. NAILS OR 2x P.T. PLATE EQUAL @ 12" O.C. SEE A/S3 FOR STAGGERED FROM BOT. DOOR TRACK REINF. INFO. PLATE TO CONCRETE W/MOUNTING ANGLE NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS ° FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. TYPICAL INTERIOR NON - BEARING WOOD FRAME WALL TYPICAL GARAGE DOOR BUCK K SCALE: N.T.S. S4 SCALE: N.T.S. S4 SF p�NpO� �N 2x CRIPPLES @ 16" O.C. W/ (2)12d TOENAILS T/B USP SPT4 w/ (6) 10dx1Y2"@24" O.C. 10d NAILS @ 8"-- O/C TYP. DOUBLE 2x —� CRIPPLE STUD TYPICAL (U.N.O.) HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS JACKS STUDS JACKS STUDS SIZE EA END EA END EA END EA END 1' - 4' (1) (2) (1) (2) (1) USP LSTA30 4' - 9' (2) 1 (3) 1 (2) (2) (1) USP LSTA30 9' -16' (3) (4) (2) (4) (2) USP LSTA30 FLAT STRAPS PER CHART ABOVE TO BE BENT OVER TOP PLATE ** HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"x10" OR GREATER HEADER 1 (2) 2x HEADER SEE PLAN S4 INTERIOR HEADER BOX HEADER (1) 2x SILL PLATE W/ (2) ONLY 12d TOENAILS. EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE "'�2x STUDS TYP. USP HTT16 TYP. U.N.O. SEE N/: ** HOLD DOWN CONNECTIONS Op�00,Q NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIF P.T. BOT. PLATE WALL HEADER DETAIL Q SCALE: N.T.S. S4 -USP SPT4 SPT24 2X STUDS @ 24" O.C. /8"Al 0" "J" BOLT @ 24" O.C. MAX. N. (2) PER BOTTOM PLATE SECTION 2X P.T. PLATE SPT4 TRANSOM FRAMING SEE SECTION AA/S1 AND BB/S1 FOR ADDITIONAL DETAILS LINTEL / / - a° a USP SPT ° a ° 2X8 P.T. BOTTOM PLATE D 5/8"x10" "J" BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) SEE TYPICAL WALL SECTION 12 (TYP-) SEE ELEV. PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2"x4" S.P.F. TOP PLATE 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. /--CRICKET AS REQUIRED USP SPT24 @ EA. STUD 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" BLOCKIN7(.) O/C FIELD 2X4 PT STUDS @ 16" O.C. (2) 2X4 PT STUDS UNDER HIP CARRIER/GIRDER TRUSS USP HTA20 @ EA. STUD - MAIN SPAN MOISTURE BARRIER ROOF TRUSS UPLIFT CONNECTOR 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. (SEE SCHEDULE) AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 90° HOOK IN K.O. BLOCK ALT. KNEEWALL ABOVE MASONRY WALL DETAIL SCALE: N.T.S. PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON PSPN516Z w/ (12)16d NAILS TOP SPLICE 2 ROWS 10d @ 3" O.C. (14 NAILS TOTAL) EA. SIDE OF . If& SPLICE STAGGERED • �10d @ 8" 0/C ATTACH ALL J EXTERIOR STUDS W/ (4) 16d TOENAILS TO TbP PLATE NOTE: PLATE LENGTHS MUST BE BOTTOM SPLIC AT LEAST 4'-0" LONG. TYPICAL OVER STUD TOP PLATE SPLICE DETAIL M SCALE: N.T.S. S4 F= 2240 LBS US USP SPT4--, QDP d—I nC r-rUSP SPT4 TRANSOM FRAMING SEE SECTION AA/S1 AND BB/S1 FOR ADDITIONAL DETAILS RECESS LINTEL USP SPT24 NAILED INTO TRANSOM FRAMING USP_ SPT22 USP SPT4 C INTO TRANSOM FRAMING rSP SPT22 SPT4 IUSPSPT4 2X TOP PLATE OVERLAPPING --10d NAILS @ 6" STAGGERED J-BOLTS @ 24" O.C. MAX -2X P.T. PLATE i 2X8 P.T. BOTTOM P TE 5/8"x10" "J" BOLT @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) SP SPT4 C ROOF TRUSS ABOVE /— 2X BLOCKING �—(2) 16d TOE NAILS EA. BLOCKING 2X8 WALL ABOVE ENTRY K.O. BLOCK W/(1) #5 CONT. & FILLED 5/8"X10" J-BOLTS @ 2'-0" O.C. C MASONRY WALL 10d NAILS @ 4 10d NAILS @ 6" O.C. STAGGERED A STAGGERED 0 o TRANSOM FRAMING BEYOND. / PLYWOOD PLYWOOD FASTENED TO TRUSSES o E SHEATHING WITH 8d COMMON WIRE NAILS @ 4" $4 O/C BOUNDARIES 6" O/C EDGES B & 8" O/C FIELD SPT4 PLYWOOD MASONRY SHEATHING WALL BELOW 5/8"Xl0' J-BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) ALTERNATE: 5/8" DIA. ATR EPDXIED MIN. 6" INTO BOND BEAM @ 24" O.C. FRAMING DETAILS ABOVE ENTRY"1 SCALE: N.T.S. U �_ Z M 0 ® o N Q Z Cz to 4✓ ur is p U — 1° w 0 i^� cn = 0 o Cl v W t— —tg MID w ce) co C W co E2MQ 0oo 0) U N L IL00 O Y t` � Y <C rn to O � 0. 0)< o A 1 NCBYDC �LIIIII Ifill N C9 �few34 • •' >b(� 0 `cd�, ccate• > - LL 11 El To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 1! 0 ON z 0�1� �>U-) M O M Q Ln O Ln z Ln L_ Q U_ CL �,- . oC U a � Q z WLU J 0 d- oZ jR za fa air (y�oo Ew= wz z y0-0 p[0-L0J LU mce ho L oZ Tp � > V • fZ a M cz G _0 ' p a U = fu W o J C?; UO ej m N N LJJ Z<o¢ Q � U'9¢ H O w 0, 90 Z t-i Cyw d o � JLn Lij owo 2�F` ,—I 2:Q Q z ¢WZ Z L v; J Z m g LU <z Uj rn SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 10 SHEET NO. S4 I SEE STRUCTURAL NOTES AND TOENAIL W/ (2) 16d NAILS NAILING SCHEDULE FOR SEE STRUCTURAL NOTES AND BACKNAIL W/ (2)16d NAILS SHEATHING DETAIL 2"x4"OUTLOOKER @ 24" O.C.Z NAILING SCHEDULE FOR USP RT16 OR EQUAL @ TOP CHORD SHEATHING DETAIL EA. OUTLOOKER 2"x4" BLOCKING FOR • • OUTLOOKER FIRST FOUR ROWS OF 45° t 24" MAX. TOP CORD BLOCKING 45°t 2X4 CONT'L" BRACE TRUSSES @ USP RT16 OR FOR FIRST FOUR FASTENED EDGES OF 2x4 CROSSBRACE EQUAL @ EA. ROWS OF TRUSSES @ 24CWCM2)10d ID SHEATHING APPROX. 8" FROM OUTLOOKER EDGES OF HEIGHT TYPICAL RIDGE FASTENED AT @ "L" BRACE TO EXTEND SHEATHING TYP. 2X4 KICKER 2x8 SYP#2 "L" BRACE TO 48" O.C. EACH JOINT W/ (3) 10d @ 8'-0" 0/C. EXTEND @LEAST 90% OF MAX. & (2)10d TOE NAILS @ LEAST WEB 2x4 CROSS BRACE WEB LENGTH & NOTCH @ EA. END @ 48" O.C. LE A LENGTH (SEE TABLE) (SEE APPROX. 8" FROM BOTTOM CHORD (SEE 2x6 P.T. GABLE TRUSS RIDGE FASTENED AT TABLE) SILL 1/2" CDX PLYWOOD OR EACH JOINT W/ (2) 10d USP RT3A WITH 8-8d 7/16" OSB SHEATHING & (2)10d TOE NAILS @ FROM LEDGER TP — —I ATTACHED W/ 10d EA. END BLOCKING NAILS @ 6" O.C. EDGES GYPSUM WALL BOARD GABLE TRUSS AND 12" O.C. FIELD 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 1/2" CDX PLYWOOD OR 10dX3" @ 3" O/C THROUGH CHORD (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM CORD ATTACHED W/ (2)16-d TOENAILS 7 7/16" OSB SHEATHING ATTACHED W/ 10d NAILS INTO 2"x6" P.T. PLATE 2"x4" LEDGER (MATCH BOTTOM CHORD @ 6" O.C. EDGES AND 12" 2x4'T' ON TOP OF PANEL BLOCKING, WEEP SCREED SLOPE OF ADJACENT SCISSOR TRUSS) O.C. FIELD FASTEN WITH 10dx3" @ 4" O/C SPACED @ 48" O.C. INSTALLED PER MANUF. 2"X6" P.T. SILL NOTCH "L" BRACE HERE MOISTURE BARRIER 5/8" x 10" "J" BOLT @ 48" O.C. WEEP SCREED 5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM USP HTA20 OR EQ. @ 6'-0" O.C. TYPICAL. INSTALLED PER MANUF. PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER USP HTA20 EA. TRUSS °� ALTERNATE USP LSTA18 STRAIGHT STRAP @ 4'-0" MOISTURE BARRIER O/C ALIGNED WITH GABLE WEB. ATTACH TO TRUSS VERT. WEB (24" O/C MAX.) W17-10dx1 1/2" AND TO MASONRY W/ (3) 3/16"x 21/4" NOTE: IF EMBEDDED SECTION TAPCONS. SECTION STRAP MISSED VERTICAL 1 2 WEB; USE MSTAM36 ON OUTSIDE SCALE: N.T.S. S5 SCALE: N.T.S. S5 SEE STRUCTURAL NOTES AND NAILING BACKNAIL W/ (2)16d NAILS SCHEDULE FOR SHEATHING DETAIL 2x4 OUTLOOKER @ 24" O.C. (OPTIONAL - SEE ELEVATIONS) SEE STRUCTURAL — TOP CORD BLOCKING USP RT16 OR EQUAL @ NOTES AND NAILING FOR FIRST FOUR ROWS 4" MAX. EA. OUTLOOKER SCHEDULE FOR OF TRUSSES @ EDGES SHEATHING DETAIL OF SHEATHING TYPICAL DOUBLE TOP PLATE 2"x4"CROSS BRACE • 2x4 CROSS BRACE APPROX. APPROX. 8" FROM USP 8" FROM RIDGE FASTENED AT RIDGE FASTENED AT SPT4 @ EA. W/ 2 1 EACH JOINT W/ (2)10d & (2) EACH JOINT W/ (2) STUD 10d TOE NAILS @ EA. END 10d & (2)10d TOE 2X6 FRAMED WALL - SEE NAILS @ EA. END WALL SECTION FOR SPACING 2x4 PANEL BLOCKING 1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE OSB SHEATHING ATTACHED FIRST (4) ROWS OF W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. AND 12" O.C. FIELD (2) 16d NAILS END TYP. TOP & BOTTOM ATTACHED 2x4 PANEL BLOCKING @ 48" 2x4 BLOCKING () 6-d TOENAILS O.C. FOR THE FIRST (4) ROWS OF TRUSSES FROM EA. END 2x4'7 ON TOP OF PANEL TYP. TOP & BOTTOM ATTACHED BLOCKING, FASTEN WITH W/ (2)16-d TOENAILS 10dx3" @ 4" O/C 2x4 LEDGER (MATCH BOTTOM CHORD SLOPE OF ADJACENT TRUSS) SECTION 3 SCALE: N.T.S. S5 REFER TO DETAIL J BACKNAIL W/ (2) 2x4 OUTLOOKER ON SHEET S5 FOR T N SEE STRUCTURAL 16d NAILS @ 24 O/C X-BRACING, AND TOP M " NOTES AND NAILING TOP CORD SP HGAM10 W/ (4) CHORD BLOCKING � ;0SHEATHING SCHEDULE FOR DETAIL USP RT16 OR BLOCKING FOR FIRST FOUR ROWS 4"x1-3/4" WEDGE INFORMATION EQUAL @ EA. OF TRUSSES @ LTS & (4) SDS 1/4" 1 1 1/ .. 2"x4" CROSS BRACE OUTLOOKER 24" MAX. EDGES OF 1 1/2" SCREWS WOOD TRUSSES go ;0 APPROX. 8" FROM SHEATHING TYP. RIDGE FASTENED AT "L" BRACE TO EXTEND 2x4 RAT RUN BRACING , • EACH JOINT W/ (2) ; AT LEAST 90% OF WEB AT 24 O.C. ON TOP OF 1 1 10d & 2)10d TOE ( LENGTH (SEE TABLE) "- BOTT. CHORD FOR 4 -- TRUSS SPANS `7uQ' NAILS @ EA. END GABLE TRUSS ATTACHED W/ 2 -16d 2x4 PANEL BLOCKING 1/2" CDX PLYWOOD OR 7/16" ' AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF @ 48" 0/C FOR THE (2)16d NAILS /_ OSB SHEATHING ATTACHED W/ 10d NAILS @ 6" O.C. 2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS FIRST ROWS OF ; TRUSSES FROM EA. E ES AND 12" O.C. FIELD 0/C W/ 2 -16d (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL END TYP. TOP & JACK TRUSS TOENAILS @ EA. END NOTES: BOTTOM ATTACHED SEE PLAN FOR 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL W/ (2)16-d TOENAILS CONNECTION MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL TOP OF PANEL OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) BLOCNG, FASTEN WITH BLOCKING, 2x4 BLOCKING W/ 10dx3" @ 4" O/C (2)12d TOENAILS EXT. WALL CONN. @ 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION NON -LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 SECTION g SEE TYP. WALL SECTION FOR SCALE: 3/4" = V-0" S5 ADDITIONAL INFORMATION. SCALE: N.T.S. �S5 SCALE: N.T.S. S5 2"x4" OUTLOOKER @ 24" - O.C. W/ (2)10d PER JOINT 1INIMUM 2x ;ROBS BRACING PRE-ENGINEERED SEE PLAN FOR WOOD TRUSSES OCATIONS) 10dx3" O/C @ 2"x4 TOENAIL 6" O/C RUNNERS W/ (2)16d TYPICAL (2)16d PER NAILS JOINT -it .. '- CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 CROSS BRACING DETAIL J SCALE: N.T.S. S5 ALTERNATE NON -DROP GABLE END DETAIL SCALE: N.T.S. 1 GABLE TRUSS "L" BRACE W/ 10d @ 4" O.C. 12 (SEE SCHEDULE FOR SIZE 6.9 1 MAX. AND LOCATION) S5 S5 `CONT. BEARING GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. 8d @ 6"O/C WOOD TRUSSES USP HGAM10 W/(4)-3/16"xi-3/4" - WEDGE BOLTS & (4) SDS 1/4" x 1 1/2" SCREWS BACKNAIL W/ (2) 2x4 OUTLOOKER 16d NAILS @ 24 O/C TOP CORD BLOCKING FOR USP RT16 OR FIRST FOUR ROWS EQUAL @ EA. OF TRUSSES @ OUTLOOKER 24" MAX. EDGES OF SHEATHING TYP. "L" BRACE TO EXTEND AT LEAST 90% OF WEB LENGTH (SEE TABLE) GABLE TRUSS 1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING ATTACHED W/ 10d NAILS @ 6" O.C. EDGES AND 12" O.C. FIELD (2)16d NAILS 2x4'7 ON TOP OF PANEL BLOCKING, FASTEN WITH 10dx3" @ 4" O/C USP HGA10 @ 36" O.C. DBL. TOP STUD WALL PLATE (SEE TYP SEC) 2x4 BLOCKING-,,-,2x4'T" BLOCKING @ 48" O.C.16d NAIL "L" BRACE ATTACHED W/ 10d NAILS @ 4" O.C. TYPICAL 7_755;:7,_i GABLE TRUSS WEB DOUBLE "L" BRACING DETAIL 5 SCALE: N.T.S. S5 2X4 "T' BLOCKING 2x4 BLOCKING @ 48" O.C. "L" BRACE ATTACHED 16d NAIL W/ 10d NAILS @ 4" 0.C- TYPICAL GABLE TRUSS WEB J SINGLE "L" BRACING DETAIL s SCALE: N.T.S. S5 DIAPHRAGM BLOCKING @ 48" O/C GABLE TRUSS TRUSS VERTICAL USP SPT24 @ EACH STUD (2) 2"x8" "L" BRACE FASTENED WITH (3) SECTION 4 16d PER SIDE SCALE: N.T.S. S5 SCISSOR GABLE "T" BRACE AS PER HIB 91 SCALE: N.T.S. S5 2 x 4 BLOCKING W/(2)10d TOE NAILS @ EACH END @ 24" O/C (TYP) \-BRACING W/(3)10d x 3" @ • EACH CONN. @ 24" O/C MOISTURE BARRIER BOND BEAM MASONRY WALL ARCHITECTURAL FINISH EXT. WALL CONN. NON -LOAD BEARING LOCATIO (UNEVEN CLG.) SEE TYP. WALL SECTION FOR ADDITIONAL INFORMATION. SCALE: N.T.S. "L" BRACING REQUIREMENTS STUD SPACING NO "L" BRACE (1) 2"x4" (U.N.O.) "L" BRACE 74" (U.N.O.) "L" BRACE 24" 07- 3'-0" 3'-0" - V-0" 6-0" & GREATER SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND (2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING NOTE: 1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. 3) SEE 6/S5 FOR MORE INFO. OVERLAP TRUSS BRACING AT LEAST TWO TRUSS SPACES 6" OVERLAP `MINIMUM (2)16d PER JOINT \-MINIMUM 2x4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL M SCALE: N.T.S. S5 "L" BRACE W/ 10d @ 4" O/C (SEE SCHEDULE FOR SIZE AND LOCATION) @ EACH STUD GABLE END BRACING DETAIL SCALE:3/4"=1'-0" MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION END JACK 1 V-0" MAX. tiiA « o c� CORNERJACK , C7 a Y W z 0 U HIP FRAMING REFERENCE PLAN E S5 0 z W a x 20'-0" MAX 20'-0" MAX "X" BRACE SEE DET. J/S5 r CONTINUOUS BOTTO14 CHORD BRACING 2X4 MIN. NOTE: 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACING THAT MY BE REQUIRED 2) "T' BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN AS PER BCSI 1-03 SCISSOR TRUSS SCISSOR TRUSS W/ DROP CEILING BRACING DETAIL LTOP & BOTTOM CHORD GABLE END BRACING @ 4'-0" O.C. MAX. FOR FIRST (4) ROWS OF TRUSSES SCALE: N.T.S. 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ 2-10d @ EA. TRUSS (NOTE: BRACING MAY BE PLACED ON EITHER TOP OR BOTTOM OF THE BOTTOM CORD) COSMETIC DROP CEILING FRAMING MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION U' !� 13 z M 0 10 z (0 Q z W cn 4✓ w 0 �U — C O w m ~ o = in CO i� V) o U L.LI I CC,,,) CO c M M —8 all � M o"00 (D Y Q0 to O j- rnQo A' B D. N.C•B •D•C >vvN ' J� 40- S o �s Z •+D qi;-C, "Z i70 4,a,� (� -••r 7r S� c C N t. c � Lr +m Y, m•... p �a W �'a=LSS\`° To the best of the Engineer's knowledge, inform❑ation❑, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 1t O ON Z O I� ? (nMo M Q V) fu Lrn d cn•2V' aa LL Ln CL F- \ M � U a 00 a z �� WJ Ol0 J �Z w za z go ce U Un Z z l7 -_1 X Wes $ o ON Z o ON U) 2: z oc c M t¢— LU M o JQ 00 U = fu 0 J �f J < O J � N ^ LL W W � �Za Z o Z W Ln LJ_I a LL J rl di o z Q z waZ Z Z Z 0 LIJ J ¢ z SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION NO. 10 SHEET NO. S5 I I I - -I;,., ''.-A . A I 1 11 1 i j I I i ITT -I-- -.1- I Tl—'— I I - - -- , —T— - I -- — -F--- 9 1X4 1/2" DRYWALL DOOR JAMB (REFER 1 X 4 1/2" DRYWALL DOOR JAMB (REFER 1 X 4 1/2" DRYWALL , UNACCEPTABLE INSTALLTION DOOR JAMB (REFER P T TO SHT. SDW2-K1 TO SHT. SDW2-K1 To SHT. SDW2-K1 FOR CONN. DETAILS PROPER INSTALLATION MAX. 8" ` DO NOT DO THIS ' 2"x BOT. PLATE W/ (2)10d @ 6" O.C. FOR CONN. DETAILS FOR CONN. DETAILS 1 X 4 1 X 4 ` #5 REBAR P, (TY ) ' 3!4"PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO 2X BOTTOM PLATE W/ 8d 4" 1 X 4 3-1/4" LONG X 3/16"0 FURRING 3/16"� X 3" LONG FURRING 3/16 0 X 3-1/2 LONG " " FURRING #5 REBAR � AND NAILED W/ 8d COMMON @ 6 O.C. EDGES AND 12 O.C. FIELD " @ O.C., 2 ROWS STAGGERED TAPCON. INTO TAPCONS TAPCONS STAGGERED STAGGERED @ 16" " ZX8 �P') BLOCK@ SPACING „ 1 DETAIL O.C. 2-ROWS INTO iX8 P.T. STAGGERED @ 16 O.C. 2-ROWS INTO 1X8 2x BAND JOIST W/ FACE NAIL 1Od PER MANUFACTURE MASONRY THROUGH 1-1 /2" DETAIL MASONRY THROUGH �� 3 DETAIL STD. 90^ . D. 90 HOOK (rYP.) @ TOP & BTTM CHORD, AND (8) 1x4 P.T. & 1 x8 P.T. 1 x8 P.T. & 2x8 P.T. FILL SOLID BOTH CELLS HOOK (TYP.) FACE NAILS 10d @TRUSS VERT. WEB TAPCON @ 16" METAL SEAT PLATE 1X4 P.T. NOTE: O.C. & 4" FROM 3/16" x 3 -1/2" DOOR JAMB (REFER 1 X 4 1/2" DRYWALL LAP SHEATHING TO DOOR JAMB (REFER EACH END W/MIN TO SHT. SDW2-K1 2"EDGE EDGED TAPCON TO SHT. SDW2-K1 FOR DOOR JAMB REFERVE ( TO SHT. SDW2-K1CONN. DETAIL ` BOTTOM OF BAND JOIST TYPICAL FOR CONN. DETAILS FOR CONN. DETAILS 1 oa @ 12° O.C. 1 X 4 ; — — — — — J FURRING"o 2X8 P.T. WITH 3/16"0 X 3" LONG TAPCONS ' t2" NOTC F� @ FIRST COURSE USP HGAM10 @ 12" O.C. w/4-SDS 1/4x1 1/2" SCREWS INTO BAND 2x P.T. AS REQ'D .. STAGGERED @ 16" O.C. ' ` JOIST & (4) 3/16"xi-3/4" WEDGE BOLTS INTO K.O. BLOCK 2x DETAIL 21 /4" DETAIL 2-ROWS INTO MASONRY 3-1 /4" DETAIL t5„ NOTCH WEB AT THE FIRST 2 COURSES BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC FILLED CELL PER FOUNDATION PLAN FILLED CELL INSTALLATION le H RETROFIT FOR MISSING EMBEDDED STRAP SCALE: N.T.S. SS SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. SCALE: N.T.S. SS 2x8 P.T. BUCK -CONNECT TO BLOCK SECTION UPLIFT CAPACITY = 945 # FOR 1 STRAP W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. A -A =1890 # FOR 2 STRAPS, -FILL t4 EMBEDMENT INTO BLK.) 1/4" MAX •. SOLID OUTES Z-0" 8" 1-PLY PRE-ENGINEERED TRUSS 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. ARCH BLKG. &BUCK 1/4" x 31/4" TAPCONS USP RT16M W/ (8) NA11 NAILS & (6) �' x 2T" BLOCK HEADER - TAPCONS 1/2" DRYWALL * (IF TRUSS IS 2 PLY INSTALL USP HTWM16 W/ (6) NAILS x 1? NAILS AND •' 8d NAILS AT 8" O.C. AT BUCK10d (4) T" X 1 t WEDGE BOLTS [ (1) STRAP =1225 # 2 x 8 45 DIAGONAL (4)10d NAILS INTO LEAVE A CUT OUT IN O.S.B. ON THE , (2) STRAPS 2450#]) BRACE(S) 2 x 8 BRACE/ BLKG. INSIDE TO ALLOW FOR INSULATION •. .' 7/16" OSB TO BE INSTALLED BOND BEAM OR CAST FOR OVERHANGS BETWEEN OVER 1 1/2" BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR POLY -CELL IN THIS AREA 2 x 8 45 DIAGONAL BRACE AT EA. IN PLACE BEAM CONTACT ENGINEER OF RECORD FOR FURTHER INSTRUCTIONS. :'' .. ' 'r: •. •• SCRIBE (NOTCH) FACE OF ARCH W/ (3)10d NAILS BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 AT EA. END RETROFIT TRUSS DETAIL OVERHAN .•:y �' •� °' CONNECT W/ 8d NAILS BRACE/ BLKG. N.T.S. INSTALL WDW. SCREW ANCHO 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 PROVIDE TAPCON WITHIN RETROFIT WALL OVERHANG DETAIL (NTS) INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU 4" MIN. OF BRACE 2 X 4 #2 SYP SCAB TO SIDE OF TRUSS AS SHOWN FOR O.H. UP TO 2'-6" FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH * DOUBLE 2X4 SCAB FOR 2'-6" TO 4'-0" O.H. NOTE: FOR OVERHANGS LESS THAN 3/4"- NO REPAIR REO-D. START OF ARC IF TRUSSES USED) W/ (3) #6 X 4%' WOOD ARCH DETAIL J 4 MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL USE 1/4' X 31/2" TAPCONS AT 16" x 0 �FRygN NAILS @ 8" O.C. TO TRUSS TO TRUSS TOP CHORD (3) SCALE: N.T.S. SS O.C. 12 + <ENOr N PLYWOOD SHEATHING 11-011 5�_p�� JACK TRUSS PROVIDED BY SEE + + TRUSS COMPANY OR PLAN 2x6 #2 SYP @ 24" O.C. + + + INISH FLO Ql 2 x 8 BUCK - CONNECT TO BLOCK SECTION + BLOCKING AS WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. B-B ROOF SHEATHING ATTACHED + REQUIRED >, e ' e '•4, /4" MAX EMBEDMENT INTO ) PER NAILING SCHEDULE ALL TO SUPPORT ° • ° e.. #5 BAR 2'-0" 8" TRUSS + SOFFIT iD ► 1-0„ �' BLOCK HEADER SOLI T TOP BTWN. ARCH NAILS (2X6 + + 9 e RED W/ 1 X 4 FURRING & BUCK TO USP RT3A 2X4 SYP ° • • '4 ' N TOP Q KNOCKOUT / i-4 EACH TRUSS e d : - •• •" ° 8d NAILS @ 8" O.C. AT BUCK 2 x 8 VERT. W/ (2 � = CHAIR BLOCK NAILS AT EA. ENDD PROVIDE 2x CONNECTOR - d MONO FOOTING - • a s• PROVIDE 2 x 8 DIAG. BRACE B PROVIDE (2) MIN. CONT. W/ (3) _ , •:. .• SIZE AND REINF. PER PLAN VERT. BRACES WHEN HGT. OF TAPCON AT EA. SIDE 12d NAILS SEE LINTEL AND SECTION DETAILS -I BRACE EXCEEDS 24" BUCK - (1) WITHIN 4" JACK TRUSS PROVIDED BY SCHED. LEAVE A CUT OUT IN O.S.B. ON T MIN. OF START OF TRUSS COMPANY OR 2x4 CLEAN FILL • ° e 2 x 8 VERT. BRACE(S) INSIDE TO ALLOW FOR INSULATION ARCH #2 SYP @ 24" O.C. EENTER SO IT .► • DIRT Z TO BE INSTALLED 2 BUILT UP PLWD. BUCK - '-0" MAX SEE PLAN PRECAST LINTEL ° ° STANDARD c N SCRIBE (NOTCH) BACKSIDE 7/16" OSB ARCH PANEL 2X4 SYP #2 CONT. (MATCH TRUSS DEPTH SEE ELEVATION a #5 BAR IN 90' HOOK TO FIT ARCH CONNECT W/ IF TRUSSES USED) W/ (2) #6 X 4%' WOOD FOR OVER HANG FILLED CELL •- •• • 8d NAILS 2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) START OF ARC SCREWS @ 16" O.C. MAX. OR IF MASONRY (MAX. 4'-0") .: . • - ' ' INSTALL WDW, SCREW --"""BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL EQUAL CREW 4' R'°`D WALL USE (2) 1/4' X 31/2" TAPCONS AT 16" •° THRU OSB INTO 2 x 8 ANCHOR INTO ARCH BLKG.K"K O.C. PER INSTALLATION DETAILS B-g ARCH DETAIL SECTION @ ENTRY rL SECTION @ROOF EXTENSION M STEMWALL FOOTING SIZE AND REINF. PERLAN AND STEMWALL MONO TO STEMWALL FOOTING SCALE: N.T.S. SS SCALE: 3/4" = V-0" SS SCALE: 3/4" = V-0" SS SCALE: 3(4" = V-0" SECTION DETAILS GLASS BLOCK INSTALLATION NOTES NOTE: IF RETROFIT FILLED CELL CONDITIONS A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY EXCEED (3) PER PROJECT, CONTACT ENGINEER OF RECORD AT LEAST 2 HOURS BEFORE PLACING MORTAR. B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP FOR ADDITIONAL INSTRUCTION. EXTENDS TO SILL. C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. MASONRY WALL. SEE PLAN FOR EXISTING BOND BEAM. REINFORCING. PROVIDE LOWER D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS HOOKED DOWEL 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE SEE SHEET D2 AND DRILL 3/4"X6" MIN. HOLE TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP FLOOR PLAN FOR A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL MORE INFO SET BAR IN EPDXY REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR HTT16 W/ (18) -16d NAILS TO CAP TO PREVENT LEAKAGE BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER W.W.M. AT PERIMETER COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. 1/4" EXPANSION BOLT (2 WHERE THIS CONDITION #5 BARS STUDS & (1) - 5/8" DIA. ALL THREAD ROD EPDXIED W/ } #5X6' EMBEDDED INTO E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 ga. PANEL PER ANCHOR) T IN. 3" OCCURS TOP WITH MIN. 3" SIMPSON "SET" EPDXY MIN. a z z0 EXISTING BOND BEAM IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING REINFORCING COVER " 6 EMBEDMENT & 3" MIN. ` SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHEREDGE -0 F.F.5" FILL CELL FULL HEIGHT W/ OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP DISTANCE U- w NON SHRINK GROUT. LAP REINFORCING NOT LESS THAN 61NCHES WHENEVER IT IS NECESSARY TO USE MORE ,• ' .. p c> THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL _ o o e v a A REINFORCING AS FOLLOWS: a 1 * PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. ;;✓ -';. SEALANT : pp g * PRESS PANEL REINFORCING INTO PLACE. ;.:.' = U 5X6 EMBEDDED INTO z 6" MIN. LAP SPLICE W/ e e — I- � � EXISTING FOOTING 245X6' IN CONC. COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL REINFORCING PANEL cai� in FILLED CELL SMOOTH. DO NO FURROW. . =s h..:; _,"'., -: ,:' e.° N DRILL 3/4"X6" MIN. HOLE F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT :`; GRADE e. v - SET BAR IN EPDXY FURROW. MAINTAIN UNIFORM JOINT WIDTH. 6" MIN. LAP p • ° ^,. O G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE N ° ' •e \ REMAIN FREE OF MORTAR. NOTE: M z ' H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS SEE GLASS BLOCK INSTALLATION NOTES. v TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT , ° �"o ;4" SAW CUT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL \ t (2) #5 REBAR. MIN. 3" TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 16" MIN. COVER EA. WAY A SECTION 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN EXISTING FOOTING GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. 1 SCALE: N.T.S. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE SECTION AT DEEP MONO FOUNDATION RETROFIT FOR MISSING MSTAM STRAP MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS, RETROFIT FILLED CELL DETAIL K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. SCALE: 3/4" =1'-0" SCALE: 3/4" =1'-0" FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR SCALE: N.T.S. INSTALLATION OF GLASS BLOCK. I __T_T I ; T1 I l .+Vlrll l6 d8dWil l :fE 11114 L L.- 1, lim 11, d ! i �I .a 1 *DIAGONAL SPACED NOTE: PENDING BEAM AT 15'-0" O.C. MAX BEARING LOCATION, THE SEE ROOF PROVIDE 2X4 MIN. BLOCKING AT BEAM CAN SIT ON TOP OF COLUMN W/ (2) HTW20 PLAN SHEATHING rk OF HIP/RIDGE, TYP.BETWEEN STRAPS JACK TRUSS (AS SHOWN) TRUSSES W/ (2) 12D NAILS EACH OR GABLE END SEE TRUSS END TO TRUSS TOP CHORD LAYOUT 2X4 BLOCKINGIr TYP. CLIP EACH TRUSS BETWEEN TRUSSES TRUSS (2) Zx8 #2 SYP W/ USP JUS46 OR JUS461F (SEE ROOF PLAN BLOCKING A 7/16"O.S.B. FLITCH BUCKET TO COLUMN FOR TYPE) SECT. A -A PLATE TOP @ T USS FRAME OUT TO BRG. SUPPORT COLUMN BUILT-UP BLOCK EDGE A (2)-2x4's OR 4x4 W/ (2)-10d G.T. NAILS @ 8" O.C. EACH PLY SEE DETAIL 4/D1 (SHOWN AS 4 x 4) FOR BEAM SIZE ADD 2X4 ALONGSIDE EXTERIOR SHEATHING TOP CHORD WHEN REQ'D (2) USP HTA20's ATTACHED PER NAILING ° TO PREVENT PLYWOOD SPAN FROM EXCEEDING TYPICAL BLOCK w/(10)-10d x 1 1/2 EA. TO COL. SCHEDULE 2x SPF #2 MAX 24" SPAN (EITHER JACK USSES HIP WALL ALT: (2) USP MSTAM36 STRAPS CENTERED AT 16" O.C. SIDE OR BOTH IF REQ'D) G.T w/(13)-10d NAILS Ea TO COL. TIE BEAM BUILDER FRAME CONTINUOUS LATERAL BRACING- RADIUS NAIL OVER X-BRACE AS SHOWN - AS REQUIRED INSTALL BLKG. AT TRUSS WEBS (2) 12D NAILS FOR NAILING AT 12" O.C. MAX X-BRACING - 2x4 SPF OR SYP BEAM @ RAISED ENTRY w/ 2-16d @EACH TRUSS WEB CROSS BRACING DETAIL JYP.) 1 HIP/RIDGE BLOCKING DETAIL 2 MASONRY WALL r4 KNEEWALL @ ENTRY FRONT WALL s SCALE: 1/2" =1'-0" SCALE: 1/2"=V-0" SCALE: 1/2" =1'-0"17-7 SCALE: 1/2" =1'-0" TRUSS NOTES. TYP. HAND FRAMING ABOVE TRUSS 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2002 CONV. FRAMED RIDGE 2X4 STUDS & PLATES AT 2'-0" O.C. MAY BE NAILED USP LSTA18 (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER EACH DIRECTION TYP. U.N.O. VERTICAL SCAB W/ MIN. (4) 12d WHEN CENTERED @ USP HD4101F BUCKET SEE PLAN BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE 2 x 6 #2 SPF 48" O.C. IT LANDS NEXT TO SPLIT TO TIE SEE ROOF PLAN FOR I FOR CANT. INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST W/ (4)10d TOP & PRE-ENG. TRUSS BEAMS TOGETHER MORE INFO COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES 2x8 BLKING. NAILED @ EACH BOTTOM OR USP RT7 OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SIDE w/ (3)12d NAILS WHEN OR HCLR/LL W/ 8 - 8d SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & REQUIRED w/ (2) USP HTW20 IN PLACE OF (4)10d SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION W/ (14) -10d X 1 1/2" EACH SEE FLOOR PLAN FOR OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED COLUMN SIZE & BASE 7/1s" OSB FLITCH PLATE ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER SEE FLOOR PLAN CONNECTION INFO REQ'D ONLY WHEN A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. COLLAR TIE FOR COLUMN INFSIZO. &ADDITIONAL INFO. INDICATED L BM. SCHEDULE/PLAN 2x4 #2 SYP NAILER, NAIL 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS EVERY 3rd 7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR TO STUDS w/3-16d @ LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING RAFTER REQ'D ONLY WHEN COLUMN SIZE & BASE EA. STUD. TOENAIL Fro. ROOF AND EXTERIOR SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" OPTION DICATEONBM A IND OPTION B CONNECTION INFO OPTION C TRUSS TO NAILER w/3-10d SHEATHING ATTACHED O.C. MAXIMUM. 2x4 SPF 2 SCHEDULE/PLAN 7,_PER NAILING SCHEDULE 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER &SHALL BE ATTACHED W/ 2-16D �� WOOD (2) NAILS AT EACH TRUSS INTERSECTION.. 4. ADDITIONAL CB SCREW EACH TRUSS RE EACH M POST ATTACHMENT M E NT CO M O N B M TO OS CKA SEE 2ND FLOOR WALL SECTION BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS OR USP RT7 @ 48" O.C. . FOR ADDITIONAL INFORMATION DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT TB SEE ROOF PLAN ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg g FOR BEAM SIZE & SCALE: 3/4 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS BEVEL CUTS CONNECTION INFO. BM. SPLICE OVER DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS (OPTIONAL) CENTER OF POST PRE-ENG. TRUSS A A 2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP SEE PLAN FOR TOP OF M MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. DIRECTION TYP. A DIAGONAL 2x8 #2 SPF RIDGE BEAM AT V-0" WOOD MAX TRUSS �}t iC 2x6 #2 SYP RAFTERS FOR SPANS 4FT USP ST18 USP ST18 • TO 8FT 2X4 RAFTERS FOR SPANS LESS TYP. U.N.O. SEE PLAN FOR TYP. U.N.O. • THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d SEE FLOOR PLAN FOR CANT. IF INDICATED USP JU26 OR IF 2 PLY COMMON TOENAILS TO RIDE BEAM COLUMN SIZE & TRUSS USP JUS26-2 TRUSS TO LEDGER SEE FLOOR FRAMING 2X4 CONT. AT CONC. MASONRY ADDITIONAL INFO. (WOOD COLUMN SHOWN) 2X8 #2 SYP CONT. LEDGER w/ PLAN AND J/S6 FOR MORE T & B CHORD BEAR MIDDLE (4) 16d NAILS ATTACH NAILS INFO. VERIFY WITH PLAN FOR LOCATION AND BEARING SUPPORT ° INTO END OF EACH FLOOR ° TRUSS, 24" O.C. MAX. (AT DIRECTION (IF PARALLE SIDE G.T. SEE 2/D2 FOR BLOCKING A —A ALTERNATE BLOCKING CORNER (�'NALS )STALL INFO) SEE FOUNDATION DETAIL @ INTERIOR BEARING ° PLAN FOR MORE INFO ,�, MASONRY WALL (TYPICAL) 3 SCALE: 1/2" =1'-0" COMMON B M ATTACHMENT g WOOD TRUSS . A PROVIDE BLOCKING AT ALL TRUSS BEARING SCALE: 3/4"=V-0" SECTION AT LOW ROOF 1 g SUPPORT WHERE TRUSS DEPTH EXCEEDS _ SCALE: 1/2" '-0" TYP. WOOD TRUSS BLOCKING DETAIL STANDARD HEEL HEIGHT SCALE: 1 /2"=V-0" VARIES 2x STUDS @ 16" O.C. ROOF SHEATHING SEE 1/S5 FOR SEE PLAN FOR W/ USP SPT22 @ ATTACHED PER ADDITIONAL 8d NAILS AT VALLEY TRUSS BASE & SPT24 @ TOP NAILING SCHEDULE 2x4 #2 SPF BRACING @ EXTERIOR SHEATHING OUTLOOKER INFO. 4" O.C. INFO. 2x BLOCKING BETWEEN 16" O.C. W/ (4) 12d COMMON TRUSSES. ATTACHED PER STUDS T TRUSS W/ (2 ) TOENAILS TO TOP SEE TRUSS PLAN 2x4 STUDS W/ USP NAILING SCHEDULE 12d TOENAILS EACH END STRUCTURAL SHEATHING PLATE & (2) 12d END MIN. (2) 2x4 FOR CONNECTION NAILS TO TRUSS SPT22 @ BASE SEE TRUSSESEEN (2) LS 12d NA NAILS TO EACH ATTACHED PER NAILING SPF TOP INFORMATION. BOTTOM CHORD PLATE J/S6 FOR MORE INFO. GABL LOW ROOF/WALL VERTIV STUD) SCHEDULE TRUSS SHEATHING ATTACHED PER NAILING SCHEDULE 2x BASE PLATE W/ (2)12d ek VARIES W/ VARIES SEE PLAN FOR WALL LOCATION 2x4 BASE PLATE W/ 1/2" PLYWOOD NAILS @ 16" O.C. ALONG W/ USP MTW12 TO BLOCKING ROOF SLOPE USP LSTA30 OR MTW12 TO FLOOR (2) 16d NAILS TO BELOW @ 16' O.C. WOOD WALL GIRDER BELOW @ 16" EACH COMMON TRUSS/ FRAMING OR TRUSS. 2X4 CONT. W/ (2) ' MIN. 2x4 #2 SPF STUDS @ O.C. TYP TOP & BOTTOM SEE PLAN 16d COMMONS 16" O.C. W/ EXTERIOR NAILS EACH SHEATHING ATTACHED STUD TYP. T&B PER NAILING SCHEDULE & MASONRY WALL BELOW: USP PLYWOOD (3) 12d TOENAILS TO �. HTA16 @ 4'-0" O.C. TO GABLE FLOORING TRUSS OR SEE PLAN FOR PLATE BELOW MASONRY WALL TRUSS BEAM BELOW: USP ROOF SYSTEM TOP OF WALL ; OR BEAM . HTW20 @ 4'4- O.C. TO GABLE MIN. 2x4 #2 SYP P.T. PLATE 16" FLOOR SYSTEM FLOOR GIRDER SEE TRUSS PLAN �,. TRUSS W/ 1/2"X8" EPDXY ANCHOR SEE PLAN FOR SEE PLAN FOR A. COMMON TRUSS LOW ROOF TRUSS W/ (2) 2x6 BLOCKING UNDER FLOOR G.T. MASONRY WALL SEE 3" FROM EACH END & @ DIRECTION CONNECTION SEE ROOF PLAN RAISED BOTTOM CHORD 2nd FLOOR WALL W/ USP SEE PLAN PLAN FOR MORE 16" O.C. MAX. FOR CONNECTION EXTENSION SEE TRUSS JUS24-2 EACH END SHEAR TRANSFER .�' INFO. SECTION MANUF. SPEC'S FOR @FLOOR CONNECTIONS TO G.T. EXTERIOR. WALL SECTION ENTRY 8 CONNECTION 22 SECTION AT HIP GABLE 12 SECTION @ BUMP OUT 39 SCALE: 3/4" = 1'-0" SCALE: 3/4" =1'-0" SCALE: 3/4" = 1'-0" SCALE: 3/4" = V-0" SCALE: 3/4"=V-0" DETAILS & SECTIONS r o o --� 0 C, Z__j r3. Z Q! vs i--i ua O w o0 �V) rll M hE ®8 C f0 M N co Ooo V a) 1" 0000 O Y t- N Qp �0 rn4o A � B N N.0 •B •D-C W Ir- NO NOk o '-•'- i d W ,sW C, . •00 % Z N o M IIYt °" `� u_ 0` iF U1 15! an . 4 1• LLE ti To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z fV Oa) N O > U-) ro M Q U-) If) a cn •,_ d- L_ U_ Ln U c� 00 Q E � Z WJ C:) s =Z za f a F EyZo0 L Z�Wtr W� z 6oJ r—i 800 i �.} W z z }0 N v, O a� 0z M w 14� € g = o J O ru J a� aPOVQZ 0 `i O=" x Iyama N LU C) a u, Z�o Z Z 8 Q z a8 Z ?Zz om z g LU Z U0 SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION N0. 10 SHEET NO. D1 THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. WEATHER RESISITIVE BARRIER TAPE HEAD FLASHING TIE-IN INSTRUXTIONS: 1. Cut, fold up & temporarily secure weat barrier above header to allow for flashing installation 2. Self -adhered flashing plus head flashing under weather resistive barrier 3. Fold weather resistive barrier back over head flashing and seal with tape SELF -ADHERED FLASHING Scale: NTS FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER EXTERIOR SHEATHING REFER TO TECHNICAL LETTER ON CHEMICAL COMPATIBILITY SELF -ADHERED FLASHING WEATHER ✓E BARRIER & IARILY SECURE EXTERIOR SHEATHING WOOD FRAME CONSTR. SELF -ADHERED FLASHIN BY LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6 IN. WEATHER RESISITIVE BARRIER SEAL TOPS OF JOI: UNDER DECKING ED FLASHING (SEE DETAIL WP07) 8 z SELF -ADHERED FLASHING WEATHER RESISTIVE BARRIER DOOR ROUGH OPENING 314"-1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING �- SELF -ADHERED FLASHING SUBFLOOR SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING 3/4"-1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SECTION -A (SEE DETAIL WP02) SELF -ADHERED FLASHING NAILING FLANGE 1 O DO NOT FLASH OVER 2 SEAL TOPS OF JOISTS BOTTOM NAILING UNDER DECKING FLANGE 8 (SEE DETAIL WP07) SELF -ADHERED FLASHING HALF ROUND WINDOW i uwnuw r�nanu��a SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK RIM JOIST INSTALL SELF -ADHERED FLASHING JAMB & HEAD FLASHING, SEE FLANGED WINDOW (SEE DETAIL WP01) SELF -ADHERED FLASHING, EXTEND A MINIMUM 6" VERTICALLY FROM BOTTOM OF THRESHOLD SELF -ADHERED FLASHING PATCH 8 z LV►a6T1k SLOPE 0.3 in: 12.0 in (0.6 cm: 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT. FIN. BUILDING PAPER SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF NEEDED IN CORNERS THROUGH SELF -ADHERED FLASHING �o RUBBERIZED RUBBERIZED ASPHALT ASPHALT ADHESIVE ADHESIVE r- SELF -ADHERED FLASHING ---, r- SELF -ADHERED FLASHING INSIDE CORNER Ground SCORED RELEASE PAPER (BEFORE FOLDING, SCORE RELEASE PAPER TO EXPOSE ADHESIVE AS SHOWN) o� Water Resistant Barrier Lath Sheathing Stucco FLASHING REQUIREMENTS R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying With ASTM D 226 for Type 1 felt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1 Exception: Omission of the water -resistive barrier is permitted in the following situations: 1. In detached accessory buildings. 2. Under exterior wall finish materials as permitted in Table R703.4 3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following or other approved method: 1.1 The fenestration manufacturer's written flashing instructions. 1.2 The flashing manufacturer's written installation instructions. 1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. 1.4 In accordance with the flashing method of a registered design professional. 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. 3. Under and at the ends of masonry, wood or metal copings and sills. 4. Continuously above all projecting wood trim. 5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6. At wall and roof intersections. 7. At built-in gutters. R703.6.2.1 Weep Screeds A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 31/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. SELF -ADHERED FLASHING PRODUCTS DETAILS TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 Detail Instructions Refer to the number marked as #loin each detail that corresponds to the numbered items in the list of instructions below: 1. Install self -adhered flashing in order as shown by numbers 2. Install flashing and weather resistive barrier to form water shedding laps 3. Self -adhered flashing can be substituted for building paper 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation and to minimize scoring cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner 8. Mechanically fasten as necessary E 3 �. kM t SELF -ADHERED FLASHING Foundation Walla SELF -ADHERED FLASHING » y 1 ° ° ° ° d. -..... ° :. ° 2 ............. a 3" MIN " 4 5 .............. SELF -ADD CREOISTLASHING R ■' SELF -ADHERED SIDECORNER FLASHING RT ' FOUNDATION WEEP SCREED Cement Plaster in accordance with ASTMC926 over wood 2nd floor Cement Plaster over block 1 st floor - 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper -7/16" O.S.B. sheathing Metal Flashing Weep Screed Installed As Per Manufact. Specs. Maintain Bottom of Weep Screed 1 1 /2" to 2" Above Roof Sheathing Note: The building paper and metal lath must be installed over the top of the weep screed. WEEP SCREED DETAIL NOT USED ■ NOT USED ■ NOT USED ■ SCALE: NOT TO SCALE 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper 7/16" O.S.B. sheathing Stampede or similar cauk bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish All inside and outside corner will need to be miter cut and caulked all butt joints need to becaulked using Stampede or sim. caulk for all ILXMI 0 u, Z o 0 Q cn a--1 w C6 Lu O 0 o t� '- - in N U 0M Cl)Lu c ry co c E - 8 T:2 os`o L LL LY Y O co a O rn "T Q rn CL rnQ o A 1 BD® NCBwDC �. l o N co a co o��O, N O coo 1Z o ILL z II- 5 W N M N �- W aU¢E__ ZU1 a n°> 0of0m Zyn�CM'0 LL O m t 0< M N ) O Cj O U F ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z N O a) N �--4 4-Jo �O (n ro 14M Ln Q - Z a (n •L V' Ln 0 N �LL.� Fa-- CL oC U CL OC) Q E its Z WLU J � d- oZ �o W0 Za ¢f age �yZo0 U Z Z �S�w c, T_q8F J . o oZ Fl� U / LLJi Z d� Z D c M ILL O V3 o 2: p (V 1 � ;a Lw U = (� a- cc LU f pz 8LLJ J wo (� iy°M- ma w0< a ¢a� Yo2Eo Z w L w <� o U 2 a Q Z F jW Z ce a Z W �I�- Z T JZ Z � IV� • J i f SCALE : AS NOTED DATE : 2/24/2014 TECH: FGUZMAN VERSION NO' 10 SHEET NO. W P N Cn .� U Q USP Florida Statewide Evaluation Report Simpson Florida Statewide Evaluation Report Q O O Stock No. Product Approval No. Basis Stock No. Product Approval No. BasisC Ca .0)V � � dj � M (n U -0 _0 0 �L 0) O O LL O CCf 0 > . � Zi E LO 2 ''C^U Z cn O O fJ U O vI M U m I- 1 O L LU Q zJ Z SHEET N0, PA 1.0 A3 FL17244.1 ESR-3455 A23 FL10446.2 ESR-2606 HD210-2 FL17232.3 ESR-3445 HU210-2 FL10655.20 ESR-2549 HD212-2 FL17232.3 ESR-3445 HU212-2 FL10655.23 ESR-2549 HD216 FL17232.3 ESR-3445 HU216 FL10655.29 ESR-2549 HD216-3 FL17232.3 ESR-3445 HU216-3 FL10655.29 ESR-2549 HD26 FL17232.2 ESR-3445 HU26 FL10655.31 ESR-2549 HD28-2 FL17232.3 ESR-3445 HU28-2 FL10655.34 ESR-2549 HD410 FL17232.4 ESR-3445 HU410 FL10655.44 ESR-2549 HD412 FL17232.4 ESR-3445 HU412 FL10655.45 ESR-2549 HD610 FL17232.4 ESR-3445 HU610 FL10655.51 ESR-2549 HD0410 FL17241.5 ESR-3444 HUC0410 FL11468.11 SIM200804 HGAIOKT FL17236.6 ESR-3448 HGAIOKT FL11470.4 SIM200803 HGAMIOKT FL17699.1 Evaluation Report HGAMIOKT FL11470.4 SIM200803 HHCP2 FL17236.7 ESR-3448 HCP2 FL10447.2 ESR-2551 HTA16 FL17680.2 Evaluation Report HETA16 FL11473.5 SIM200802 HTA20-18 FL17680.2 Evaluation Report HETA20 FL11473.5 SIM200802 HTT16 FL17324.1 Evaluation Report HTT16 FL11496.1 ES-0130 HTT45 FL17324.1 Evaluation Report HTT22 FL11496.1 ES-0130 HTT4 FL17219.2 ER-0200 HTS 16 FL 10456.22 ESR-2613 HTTS FL17219.2 ER-0200 HTS20 FL10456.23 ESR-2613 HTW16 FL17244.8 ESR-3455 HTS24 FL10456.24 ESR-2613 HTW20 FL17244.8 ESR-3455 HTS30 FL10456.26 ESR-2613 HTW24 FL17244.8 ESR-3455 HTSM16 FL11473.11 SIM200802 HTW30 FL17244.8 ESR-3455 HTSM20 FL11473.11 SIM200802 HTWM16 FL6223.2 Evaluation Report HGT2 FL10456.18 ESR-2613 HTWM20 FL6223.2 Evaluation Report HGT3 FL10456.19 ESR-2613 HUGT2 FL6223.3 Evaluation Report HUS210-2 FL10655.92 ESR-2549 HUGT3 FL6223.3 Evaluation Report HUS212-2 FL10655.93 ESR-2549 HUS210-2 FL17232.7 ESR-3445 HUS26 FL10655.94 ESR-2549 HU5212-2 FL17232.7 ESR-3445 HUS28 FL10655.96 ESR-2549 HUS26 FL17232.7 ESR-3445 HUS28-2 FL10655.97 ESR-2549 HUS28 FL17232.7 ESR-3445 LU24 FL10655.103 ESR-2549 HUS28-2 FL17232.7 ESR-3445 LU26 FL10655.104 ESR-2549 JL24 FL17232.8 ESR-3445 LUS210-2 FL10655.107 ESR-2549 JL26 FL17232.8 ESR-3445 LUS24 FL10655.109 ESR-2549 JUS210-2 FL17232.12 ESR-3445 LUS26 FL10655.111 ESR-2549 JUS24 FL17232.11 ESR-3445 LUS26-2 FL10655.112 ESR-2549 JUS26 FL17232.12 ESR-3445 LUS28 FL10655.113 ESR-2549 JUS26-2 FL17232.12 ESR-3445 LUS46 FL10655.118 ESR-2549 JUS28 FL17232.12 ESR-3445 LEG3 FL10667.71 ESR-2615 JUS46 FL17232.12 ESR-3445 MST60 FL10852.7 ESR-2105 KLEG3 FL17241.15 ESR-3444 LSTA12 FL10852.4 ESR-2105 KST260 FL17244.15 ESR-3455 LSTA15 FL10852.4 ESR-2105 LSTA12 FL17244.18 ESR-3455 LSTA18 FL10852.4 ESR-2105 LSTA15 FL17244.18 ESR-3455 LSTA24 FL10852.4 ESR-2105 LSTA18 FL17244.18 ESR-3455 LSTA30 FL10852.4 ESR-2105 LSTA24 FL17244.18 ESR-3455 LSTA36 FL10852.5 ESR-2105 LSTA30 FL17244.18 ESR-3455 LTT19 FL11498.3 ER-130 LSTA36 FL17244.18 ESR-3455 LTT20B FL11496.3 ER-130 LTS19 FL17219.3 ER-0200 LTT131 FL11496.3 ER-130 LTS20B FL17219.3 ER-0200 LTS12 FL10456.29 ESR-2613 LTT131 FL17219.3 ER-0200 LGT2 FL11470.7 SIM200803 LTW12 FL17244.8 ESR-3455 LS30 FL10446.15 ESR-2606 LUGT2 FL17240.2 ESR-3447 A34 FL10446.3 ESR-2606 MP3 FL17244.22 ESR-3455 LTP4 FL10446.19 ESR-2606 MP34 FL17244.23 ESR-3455 LS50 FL10446.16 ESR-2606 MP4F FL17244.24 ESR-3455 WM1416 FL10667.86 ESR-2615 MP5 FL17244.22 ESR-3455 MSTA12 FL10852.8 ESR-2105 MPH3516 FL17240.3 ESR-3447 MSTA15 FL10852.8 ESR-2105 MSTA12 FL17244.18 ESR-3455 MSTA18 FL10852.9 ESR-2105 MSTA15 FL17244.18 ESR-3455 MSTA24 FL10852.9 ESR-2105 MSTA18 FL17244.18 ESR-3455 MSTA36 FL10852,9 ESR-2105 MSTA24 FL17244.18 ESR-3455 MSTC40 FL10852.11 ESR-2105 MSTA36 FL17244.18 ESR-3455 MSTC52 FL10852.11 ESR-2105 MSTC40 FL17244.26 ESR-3455 MTS12 FL10456.33 ESR-2613 MSTC52 FL17244.26 ESR-3455 MTS16 FL10456.34 ESR-2613 MTW12 FL17244.8 ESR-3455 MTS18 FL10456.35 ESR-2613 MTW16 FL17244.8 ESR-3455 MTS20 FL10456.36 ESR-2613 MTW18 FL17244.8 ESR-3455 MGT FL11470.9 SIM200803 MTW20 FL17244.8 ESR-3455 MBHA3.56/11.25 FL10866.12 ESR-2616 MUGT15 FL17240.5 ESR-3447 MBHA3.56/16 FL10866.12 ESR-2616 NFM35X12 FL578.2 Evaluation Report HDU2-SDS2.5 FL10441.4 ESR-2330 NFM35X16U FL578.3 Evaluation Report GLTV3.516 FL10667.8 ESR-2615 PAU44 FL17239.13 ESR-3449 FGTR FL11473.2 SIM200802 PAU66 FL17239.13 ESR-3449 CS16 FL10852.1 ESR-2105 PHD2A FL17219.4 ER-0200 H1 FL10456.5 ESR-2613 PHXU3516 FL17241.20 ESR-3444 H10 FL10456.6 ESR-2613 RFUS FL6223.5 Evaluation Report H10-2 FL10456.7 ESR-2613 RS150 FL17244.27 ESR-3455 H10A FL10456.6 ESR-2613 RT15 FL17236.11 ESR-3448 H3 FL10456.13 ESR-2613 RT16-2 FL17236.10 ESR-3448 H4 FL10456.14 ESR-2613 RT16A FL17236.10 ESR-3448 H5 FL10456.15 ESR-2613 RT3A FL17236.11 ESR-3448 H2.5 FL10456.11 ESR-2613 RT4 FL17236.11 ESR-3448 H2.5A FL10456.12 ESR-2613 RT5 FL17236.11 ESR-3448 H8 FL11470.3 SIM200803 RT7 FL17236.11 ESR-3448 SP1 FL10456.41 ESR-2613 RT7A FL17236.11 ESR-3448 SP2 FL10456.42 ESR-2613 RTSA FL17236.11 ESR-3448 SP4 FL10456.43 ESR-2613 SPT22 FL17244.30 ESR-3455 SP6 FL10456.44 ESR-2613 SPT24 FL17244.31 ESR-3455 SP8 FL10456.45 ESR-2613 SPT4 FL17244.32 ESR-3455 SPH4 FL10456.46 ESR-2613 SPT6 FL17244.32 ESR-3455 SPH6 FL10456.47 ESR-2613 SPTB FL17244.32 ESR-3455 SPHS FL10456.48 ESR-2613 SPTH4 FL17244.32 ESR-3455 U24 FL10655.141 ESR-2549 SPTH6 FL17244.32 ESR-3455 HHUS28-2 FL10655.3 ESR-2549 SPTHB FL17244.32 ESR-3455 HHUS410 FL10655.4 ESR-2549 SUH24 FL17232.14 ESR-3445 HGUS5.25/12 FL11468.11 SIM200804 THD28 FL17232.17 ESR-3445 HGUS414 FL11468.10 SIM200804 THD28-2 FL17232.17 ESR-3445 HD08-SDS3 FL10441.1 ESR-2330 THD410 FL17232.17 ESR-3445 MSTAM24 FL11473.19 SIM200802 THD412 FL17232.17 ESR-3445 MSTAM36 FL11473.19 SIM200802 THD612 FL17232.17 ESR-3445 MSTCM40 FL11473.19 SIM200802 THDH414 FL17232.18 ESR-3445 HHETA20 FL11473.9 SIM200802 UGTS3F FL2033.1 Evaluation Report LGT3-SDS2.5 FL11470.7 SIM200803 UPHDS FL17219.6 ER-0200 LGUM26-2 FL11473.12 SIM200802 PRODUCT APPROVAL SPECIFICATION SHEET As required by Florida Statute 553.842 and Florida Administrative Code 96-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Category/Subcategory Manufacturer Product Description Approval Number(s) Test Pressures 1. EXTERIOR DOORS A. SWINGING ThermaTru Smooth -Star and Benchmark FL15225.5 +67.0/-67.0 psf ThermaTru Premium, Construction Series and Benchmark FL15225.6 +47.0/-47.0 psf ThermaTru Fiber Classic /Smooth Star FL15000.1 +55.0/-55.0 psf B. SLIDING General Aluminum Company Series 420/430 FL15332.1 - FL15332.5 +40.0/-40.0 psf C. SECTIONAL Ciopay Building Products Residential WindCode Doors W5 (8X7) FL15279.37 +30.0/-32.0 psf Ciopay Building Products Residential WindCode Doors W5 (16X7) FL15279.53 +30.0/-30.0 psf Ciopay Building Products Residential WindCode Doors W6 (8X7) FL15279.85 +38.0/-42.0 psf Ciopay Building Products Residential WindCode Doors W6 (16X7) FL15279.102 +37.0/-41.0 psf D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,and 847 Single &Pairs of Doors FL11537.1 N/A (see inst sht) 2. WINDOWS A. SINGLE HUNG General Aluminum Company Series 1550/1570 FL15217.4 - FL15217.5 +50.0/-55.0 psf General Aluminum Company Series 190071970 FL15217.7 - FL15217.9 +40.0/-50.0 psf B. HORIZONTAL SLIDER General Aluminum Company Series 1580/1590 FL15288.1 - FL15288.2 +40.0/-50.0 psf General Aluminum Company Series 1980/1990 FL15288.3 - FL15288.4 +40.0/-50.0 psf C. FIXED General Aluminum Company Series 1550/1570 FL15278.4 - FL15278.5 +40.0/-40.0 psf General Aluminum Company Series 1900/1970 FL15278.7 - FL15278.9 +40.0l-50.0 psf D. MULLION General Aluminum Company 1445, 5347 and 5547 Vertical Mullion FL15333.7 N/A E. OTHER 3. PANEL WALL A. SIDING James Hardie Building Prod. Cemplank Lap Siding and Hardiepiank Lap Siding FL13192.1 - FL13192.2 N/A B. SOFFITS Alside Solid and Vented Soffit FL15272.1 - FL15272.2 +70.0/-70.0 psf C. OTHER 4. ROOFING PRODUCTS A. ASPHALT SHINGLES Certain Teed Corporation CT20 (and AR), Landmark 30/40 (and AR), FL5444.1 N/A XT25 (and AR), XT30 (and AR) B. UNDERLAYMENTS Tamko 151b Felt Underlayment FL72328.6 N/A HomeGuard Building Products, Inc ToughSkin Synthethic Underiayments FL21675.1 N/A C. ROOFING FASTENERS NOT USED D. ROOF VENTILATORS Thompson Arch Metal Comp. Off Ridge Vents FL5219.1 - FL5219.3 N/A Florida Metal Products, Inc Vent RV10 FL2075.1 N/A Lomanco, Inc DA-4 Exahust Vent FL17202.1 N/A O'Hagin Manufacturing, LLC O'Hagin's Cloakded Vent Tile FL16588.1 N/A E. ROOFING TILES Borai Tile Villa 900 FL7849.24 - FL7849:26 N/A Boral Tile Saxony 900 FL7849.13 - FL7849.16 N/A F. OTHER 5. SHUTTERS A. STORM PANELS Global Protection Products Galvanized Steel Storm Panels FL15076.1 - FL15076.2 N/A Global Protection Products GPP Fabric Shutter Series 2000 FL15088.1 N/A Town and Country Industries Safety Edge Storm Panels FL12856.1 +54.0/-54.0 psf All American Shutters Galvanized Steel Storm Panels FL17869.1 N/A S. STRUCTURAL COMPONENTS A. WOOD CONNECTORS/ USP Structural Conn. see chart ANCHORS Simpson Strong -Tie see chart B. TRUSS PLATES ITW Building Components Alpine Truss Plates FL1999.1 - FL1999.4 N/A MiTek Industries, Inc. Truss Plates FL2197.1 - FL2197.5 N/A C. ENGINEERED LUMBER Boise Eng. Wood Prod. Versa -Lam SP FL1644.1 N/A Boise Eng. Wood Prod. Wood I -Joists ALLJOIST FL1645.1 NIA Weyerhaeuser Engineered lumber -TJI FL1630.1-FL1630.11 N/A Weyerhaeuser iLevel Rim Board, LVL, PSL, LSL FL6527.1 - FL6527.4 N/A D. MATERIAL Cast -Crete Corp. High Strength Concrete Lintels FL158.1 N/A Commercial Concrete Products, Inc. High Strength Concrete Lintels FL1774 NIA Powers Steel, Inc. PSboxBLT, PSboxBLT(5-5/8) FL5450.1 N/A Powers Steel, Inc. PowerBOXB Lintels FL11383.1 N/A The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the jobsRe; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I understand these products may have to be removed "rf approval cannot be demonstrated during inspection. APPLICANT SIGNATURE DATE n Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 2 1/9rz017 FL#15225-R3 Code Entity or Date Date Date Pending Date Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 Therma-Tru Corporation Rick Wright National Accreditation & Ryan J. King, P.E. 06/28/2015 06/13/2015 07/05/2015 Approved Category: Exterior Doors (419) 298-1740 Management Institute (813) 767-6555 SubCategory: Swinging Exterior Door Assemblies rickw@rwbldgconsultants. Compliance Method: Certification Mark or Listing com FL#15225-R3 Products Quality Assurance Approved for Use Approved for Use Impact Desian Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 5 e. ",Smooth-Star", and " Benchmark by 6/8 and 8/0 Opaque and Glazed Fiberglass Door with 12131/2021 No Yes No N/A Therma-Tru"a and without Sidelites. Inswing and Outswing 6 f. "Premium Series"„ "Construction 618 and 810 Opaque and Glazed Steel Door with 12/31/2021 No Yes No N/A Series"a and "Benchmark by Therma-Tru" Transoms. With and without Sidelites. Inswing and with Transoms Outswing Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail FL#15279-R4 Code Entity or Type Versio Manufacturer Contact Engineer & License Validated By Revision 2014 Clopay Building Products Company Mark Westerfield Intertek Testing Services NA, Approved Category: Exterior Doors (513) 770-6062 Inc. (513) 519-6566 SubCategory: Sectional Exterior Door Assemblies mwesterfield@clopay.com Compliance Method: Certification Markor Listing FL#15279-R4 Products Page 1 of 1 1/92017 Date Date Date Pending Date Validated Submitted FBC Approval Approved Status Gary Pfuehler 06/12/2015 03/19/2015 06/21/2015 Quality Assurance Approved for Use Approved for Use Impact Design Seq # Product Model. Number or Name Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure 37 037 W5-09 PAN-21`151: 84A, 94, 73, 75, 1500, 190, 76, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/21/2028 No Yes No +30 PSF/-32 76V, 4RST, 4RSF, 6RST, 6RSF, 2RST, 48, 42, 55, 48B, WINDCODE® W5 Garage Door PSF 42B, 55S, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV 53 053 W5-16 PAN-21`153: 84A, 94, 73, 75, 1500, 190, 4RST, Steel Pan (min. 25 ga.) Double -Car (97' to 16'0" 05/21/2028 No Yes No +30 PSF/-30 4RSF, 6RST, 6RSF, 48, 42, 55, 48B, 428, 55S, GD5S, wide) WINDCODE® W5 Garage Door PSF GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV 85 085 W6-09 PAN-21`153: 73, 75, 84A, 94, 42, 48, 42B, 48B, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/21/2028 No Yes No +38 PSF/-42 4RST, 6RST, GD5S, GR5S, AR5S, ED5S WINDCODE® W6 Garage Door PSF 102 102 W6-16 PAN-2F153: 73, 75, 84A, 94, 42, 48, 42B, 48B, Steel Pan (min. 25 ga.) Double -Car (92" to 16'2" 05/21/2028 No Yes No +37 PSF/-41 4RST, 6RST, GD5S, GR5S, AR5S, ED5S wide) WINDCODE® W6 Garage Door PSF Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/92017 FL#15288-R2 Code Entity or Date Date Date Pendina Date Type Versio manufacture Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Affirmation 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 04/30/2015 04/30/2015 05/10/2015 Approved Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 SubCategory: Horizontal Slider bsitlinger@miwd.com Compliance Method: Evaluation Reportfrom a Florida Registered Architect or a Licensed Florida Professional Engineer FL#15288-R2 Products Quality Assurance Approved for Use Approved for Use Impact Design Sea # Product Model. Number or Name n Product Description Expiration Date Contract Exp 'n HVHZ V Outside HVHZ Resistant Pressure 1 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12/31/2017 No Yes No N/A 72X54 2 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12/31/2017 No Yes No N/A 72X54 3 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/31/2017 No Yes No N/A SLIDER 108X48 4 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12131/2017 No Yes No N/A SLIDER Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Pagel of 2 v92017 Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/92017 FL#15000-R2 Coe Entity or Date Date Date Pending Date Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 Therma-Tru Corporation Rick Wright Lyndon F. Schmidt, P.E. Ryan J. King, P.E. 06/28/2015 05/29/2015 07/05/2015 08/19/2015 Approved Category: Exterior Doors (419) 298-1740 PE-43409 (813) 767-6555 SubCategory: Swinging Exterior Door Assemblies rickv,@rwbldgconsultants. Compliance Method: Evaluation Report from a com Florida Registered Architect or a Licensed Florida Professional Engineer FL#15000-R2 Products Quality Assurance Approved for Use Approved for Use Impact Design Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 a. &quct;Fiber-Classic"a or "Smooth-Star"a 6'8 "Non-Impact" Opaque Fiberglass 12/31/2018 Yes Yes No N/A Door with & without Sidel te(s) - Outswing (X, OX or XO, OXO, XX, OXXO Configurations) Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail FL#11537-R6 Code Entity or Type Versio Manufacturer Contact Enaineer & License Revision 2014 CURRIES Division of AADG, Inc Nelson Kraschel UL LLC Category: Exterior Doors (641) 423-1334 SubCategory: Exterior Door Components nelson.kraschel@doorgro Compliance Method: Certification Markor Listing up.com FL#11537-R6 Products Sea # Product Model. Number or Name Product Description 1 607, 707, 727, 747, and 847 Single and Pairs of Doors Flush, Glazed, and Lowered single and pairs of hollow metal doors. 2 M, CM, and G Series Frames Three sided and four sided single and pairs of frames. Tansom frames. Validated By Ted Berman, PE (305) 868-4707 Page 1 of 1 1/102017 Date Date Date Pend Ina Date Validated Submitted FBC Approval Approved Status 07/21/2015 07/21/2015 07/27/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Desi n Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 12/31/2017 Yes Yes Yes N/A 12/31/2017 Yes Yes Yes N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 3 1/92017 FL#15278-R4 Code Entity or Date Date Date Pending Date Type Versio Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 MI Windows and Doors Brent Sibinger Luis Roberto Lomas Steven M. Urich, PE 09/01/2015 08/31/2015 09/05/2015 10/16/2015 Approved Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 SubCategory: Fixed bsitlinger@miwd.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#15278-R4 Products Sea # Product Model, Number or Name Product Description 4 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 9BX48 FIN 5 ALUMINUM PW SERIESGA 195 A SERIES GA 195 ALUMINUM PW NI 72X72 FLANGE 7 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 96X48 FLANGE 8 SERIES GA 275 THERMALLY BROKEN ALUMINUM PW SERIES GA 275 THERMALLY BROKEN ALUMINUM PW NI 72X72 FIN 9 SERIES GA 505 ALUMINUM PW SERIES GA 505 ALUMINUM PWN172X72 FIN Quality Assurance Approved for Use Approved for Use Impact Design Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 12/31/2017 No Yes No N/A 12/3l/2017 No Yes No N/A 12/31/2017 No Yes No N/A 12/31/2017 No Yes No NIA 12/3l/2017 No Yes No N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Pagel of 1 1/92017 FL#13192-R4 FL#15272-R1 Code Entity or t L Date Date Date Pendina Date Cod s or �r]SLY_ Date Date a _ Date Pend Ina Date _ Type Versio Manufacturer Contact Eno ineer & License Validated By Validated Submitted FBC Approval Approved Status Type_ Versio Manufacture Contact Enaineer& License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 James Hardie Building Products, Inc. Pingsheng Zhu Ronald I. Ogawa John Southard, P.E. 08/26/2015 08/17/2015 09/07/2015 10/16/2015 Approved Revision 2014 Alside Nick Thompson Lyndon F. Schmidt, P.E. Ryan J. King, P.E. 02/23/2015 02/19/2015 03/01/2015 04/15/2015 Approved Category: Panel Walls (909) 349-2927 PE-24121 (352) 367-2526 Category: Panel Walls (330) 922-2389 PE-43409 (813) 767-6555 SubCategory: Siding pingsheng.zhu@jameshar SubCategory: Soffits nthompson@alside,com Compliance Method: Evaluation Report from a die.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Professional Engineer Professional Engineer FL#13192-R4 Products FL#15272-R1 Products Quality Assurance Approved for Use Approved for Use Impact Deslan Quality Assurance proved for Use Approved � A for Use Impact Design Sea # Product Model. Number or Name Product Description Contract Contract Expiration DateIn HVHZ Outside HVHZ Resistant Pressure Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 Cemplank Lap Siding fiber -cement lap siding 01/01/2018 Yes Yes N/A N/A 1 a. "2T" Soffit Vent or Solid Vinyl Soffit 12/31/2018 No Yes No N/A 2 HardiePlank Lap Siding fiber -cement lap siding 01/01/2018 Yes Yes N/A N/A 2 b. "Alliance T4" Soffit Vent or Solid Vinyl Soffit 12131/2018 No Yes No N/A FL#15332-R3 Products Seq # Product Model, Number or Name 4 SERIES 420 ALUMINUM SGD REINFORCED 5 SERIES 420 ALUMINUM SGD REINFORCED 7 SERIES 420 REINFORCED ALUMINUM SGD 8 SERIES 430/440 ALUMINUM SGD 9 SERIES 430/440 REINFORCED ALUMINUM SGD FL#15217-R4 Code Type Versio Manufacturer Revision 2014 MI Windows and Doors Category: Windows SubCategory: Single Hung Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#15217-R4 Products Sea # Product Model. Number or Name 4 SERIES GA 195 ALUMINUM SH 5 SERIES GA 195 ALUMINUM SH 7 SERIES GA 195 ALUMINUM SH 8 SERIES GA 195 ALUMINUM TRIPLE SH 9 SERIES GA 195 ALUMINUM TWIN SH FL#15333-R2 Code Tvpe Versio Manufacturer Revision 2014 MI Windows and Doors Category: Windows SubCategory: Mullions Compliance Method: Evaluation Reportfrom a Florida Registered Architect or a Licensed Florida Professional Engineer FL#15333-R2 Products Sea # Product Model. Number or Name 7 1445, 5347 AND 5547 VERTICAL MULLION FL#5444-R10 Code TYDe Versio Manufacturer Revision 2014 CertainTeed Corporation -Roofing Category: Roofing SubCategory: Asphalt Shingles Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#5444-R10 Products Sea # Product Model. Number or Name 1 CertainTeed Asphalt Roofing Shingles Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Product Description SERIES 420 ALUMINUM SGD REINFORCED OX, XO, XX 96"x96"a SERIES 420 ALUMINUM SGD REINFORCED XXX 143",x96" SERIES 420 REINFORCED ALUMINUM SGD OXO 146"x96" SERIES 430/440 ALUMINUM SGD XXX 143"x80" NON -REINFORCED SERIES 430/440 REINFORCED ALUMINUM SGD XXX 143"x96" Page 1 of 2 1/92017 Quality Assurance Approved for Use Approved for Use Impact Design Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 12/3l/2017 No Yes No N/A 12/31/2017 No Yes No N/A 12/31/2017 No Yes No N/A 12/31/2017 No Yes No N/A 12/3l/2017 No Yes No N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity or Contact Engineer & License Brent Sitlinger Luis Roberto Lomas (717) 365-3300 PE-62514 bsitlinger@miwd.com Product Description SERIES GA 195 ALUMINUM SH NI 44X84 SERIES GA 195 ALUMINUM SH NI 54X72 SERIES GA 195 ALUMINUM SH NI 54X72 SERIES GA 195 ALUMINUM TRIPLE SH NI CONTINUOUS HEAD AND SILL 108X72 NON IMPACT SERIES GA 195 ALUMINUM TWIN SH NI CONTINUOUS HEAD AND SILL 88 1/8X72 Validated ev Steven M. Urich, PE (717) 317-8454 Pagel of 2 1/92017 Date Date Date Pending Date Validated Submitted FBC Approval Aporoved Status 06/30/2015 06/25/2015 07/06/2015 08/19/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Design Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 12/31/2017 No Yes No N/A 12/31/2017 No Yes No N/A 12/31/2017 No Yes No N/A 12/31/2017 No Yes No N/A 12/31/2017 No Yes No N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity or Contact Engineer & License Brent Sitiinger Luis Roberto Lomas (717) 365-3300 PE-62514 bsitinger@mMd.com Product Description 1445, 5347 AND 5547 VERTICAL MULLION Validated By Steven M. Urich, PE (717) 317-8454 Page 1 of 1 1/92017 Date Date Date Pendina Date Validated SuTm-itted FBCAooroval Aporoved Status 06/29/2015 06/19/2015 07/05/2015 08/19/2015 Approved Quality Assurance Approved for Use Approved for Use act Im � Design Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 12/31/2017 No Yes Yes N/A Florida Department of Business & Professional Regulation Page 1 of 2 Building Codes and Standards 1/92017 Product Approval Application Detail Entity o Date Date Pending Date E r Date Contact Engineer & License i Validated Submitted FBC Approval Approved Status o� Ena Validated By S Mark Harper Robert Nieminen John W. Knezevich, PE 12/14/2016 12/08/2016 12/15/2016 Pending FBC Approval (610) 651-5847 PE-59166 (954) 772-6224 markd. harner@saint-gob ain.com Quality AAoroved for Use Approved for Use Impact Design Expiration Date in HVHZ Outside Product Description Contract a HVHZ Resistant Pressure d 3-tab, 4-tab, strip (no -cut-outs), laminated and 07/0312017 No Yes N/A N/A architectural asphalt roof shingles N N N U � Q O 1� C .� Ca U -0 ry 0- U) dj :3 cti O ca to O � O � CU O O CCf U_ O > -� E O CU /U) Z Z W J Cn CL U �e r�n V O O L 0_ U O +J L M� W V Q ICU L.� VL w � W � � Q W Z W J Z Q J d SHEET NO. PA 1.1 Cll 1. R O � U Florida Department of Business & Professional Regulation Page 1 of 1 CU K Building Codes and Standards 1/9Q017 C C13 -O 0- ' . Florida Department of Business & Professional Regulation Page 1 of 3 Florida Department of Business & Professional Regulation Page 1 of 1 -11-0 W N Building Codes and Standards 1/9/2017 Building Codes and Standards 2/MO17 Product Approval Application Detail .0)U ''"' ,C/) O U ' Product Approval Application Detail Product Approval Application Detail FL#5219-R3 O t.' FL#12328-R7 Products Code Enity or gatt_e Date Date Pendina Dade O O �j Quality Assurance Approved for Use Approved for Use Impact Design FL#21675-RO Tvpe Versio Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status j sea # Product Model. Number or Name Product Description Contract Expiration Date i HVHZ Outside HVHZ Resistant Pressure Revision 2014 Thompson Architectural Metals Company, Inc. Scott Brown James L. Buckner Steven M. Urich, PE 05/01/2015 04/29/2015 05/10/2015 06/23/2015 Approved — vLi . Code Ent' or ate Date Date Pending to :jam 6 No. 15 ILL Asphalt saturated organic felt 01/07/2019 No Yes NIA N/A Type Versio Manufacturer Contact Enaineer & License Validated By ValidatedSubmitted FBC Approval Approved Status Category: Roofing (813) 248-3456 PE-31242 (717) 317-8454 c O E y--- > New 2014 HomeGuard Building Products, Inc. John Cheslak ntertekTesting Services NA, IntertekTesting Services 0201/2017 01/25/2017 02/03/2017 SubCategory: Roofing Accessories that are an flvalidation@yahoo,com ,� 0 O t Integral Part of the Roofing System - Approved Compliance Method: Evaluation Report from a (D L C-0 Q Category: Roofing (904) 240-1382 Inc. NA, Inc. Florida Registered Architect or a Licensed Florida Cn O Search Criteria SubCategory: Underlayments john.cheslak@hgwrap.co (604) 520-3321 Professional Engineer C (o �[— '^ Co Compliance Method: Evaluation Report from a m FL#5219-R3 Products .0 .� �/ J Code Version: 2014 FL It. 12328 Product Evaluation Entity Application Type: ALL Product Manufacturer: ALL Quality Assurance Approved for Use Approved for Use Impact Design Category: ALL Subcategory: ALL FL#21675-RO Products Sea # Product Model. Number or Name Product Description Contract Fxpiration Date in HVHZ Outside HVHZ Resistant Pressure .r Application Status: ALL Compliance Method: ALL Quality Assurance Approved for Use Approved for Use Impact Deskin 1 1- "Flat Top Off Ridge Vent with Baffle for Tile" Minimum 26 Gauge Steel, Nominal 4', 6', 12131/2019 No Yes No N/A Quality Assurance Entity Contract Expired: ALL Product Model, Num ber or Name: ALL Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant essure 8', or 10' Wide Off Ridge Vent Attached to ' Product Description: ALL Approved for use in HVHZ: ALL 1 ToughSkin Synthetic Underlayments ToughSkin 15, ToughSkin 20, ToughSkin 25, 01/01/2018 No Yes N/A N/A Wood Deck ToughSkin 30ToughSkin 50 2 2- "Round Top Off Ridge Vent with Baffle for Minimum 26 Gauge Steel, Nominal 4', 6', 12/31/2019 No Yes No N/A , Approved for use outside HVHZ: ALL Impact Resistant: ALL Tile"a 8', or 10' Wide Off Ridge Vent Attached to Design Pressure: ALL Date From: ALL Wood Deck Date To: ALL1 1 3 3- "Standard Off Ridge Vent with Permanent Baffle Minimum 26 Gauge Steel, Nominal 4', 6Ƈ, 12/31/2019 No Yes No N/A r_ for Shingles"a 88#39;, or 10' Wide Off Ridge Vent Attached to Wood Deck Florida Department of Business & Professional Regulation Page 1 of 1 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/10/2017 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/9/2017 Building Codes and Standards 1/10/2017 Product Approval Application Detail g ! Product Approval Application Detail Product Approval Application Detail FL#17202-R1 I, FL2075-R7 Code Entityor Dte Date pate Pending Date FL#16586-R1 Code Entity or ate Date Pending ate Tye ersio Manufacturer Contact Engineer& License Validated By Validated Submitted FBC Approval Approved Status Tvpe Versio Manufacturer Contact Engineer & License Validated By Validated b itted FBC Approval roved a s Revision 2014 Lomanco, Inc Andrew Carter James L. Buckner, P.E. Steven M. Urich, PE 05/01/2015 05/01t2015 05/10/2015 06/22/2015 Approved Code Entityor Date Date Date Pending g ( ) (717) 317-8454 Tvpe Versio Manufacturer ContactEngineer & License Validated By Validated Submitted FBC Approval Approved Status Affirmation 2014 Florida Metal Products Inc. Clark Jones Miami -Dade BCCO - EVL Miami -Dade BCCO - VAL 02/27/2015 02127l2015 03/09/2015 Approved Category:Roofin 501 982-6511 PE-31242 Category: Roofing (904) 783-8400 (786) 315-2590 SubCategory: Roofing Accessories that are an acarter@lomanco.com Affirmation 2014 O'Hagin Manufacturing, LLC Gregory Daniels Miami -Dade BCCO - CER Ted Berman, PE 06/17/2015 06/17/2015 06/25/2015 Approved SubCategory: Roofing Accessories that are an clark@flamoo.com Integral Part of the Roofing System Category: Roofing (707) 872.3620 (305) 868-4707 Integral Part of the Roofing System Compliance Method: Evaluation Report from a SubCategory: Roofing Accessories that are an gdaniels@ohagin.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Integral Part of the Roofing System )' Trance f. Professional Engineer Compliance Method: Certification Mark or Listing - Product Evaluation Entity P � 9 FL#2075-R7 Products FL#17202-R1 Products FL#16588-R1 Products Quality Assurance Approved for Use Approved for Use Impact Desian Quality Assurance Approved for Use Approved for Use Impact Design Quality Assurance Approved for Use Approved for Use Impact Design # Product Model. Number or Name Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure �£� Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 RV10 RV10 ALUMINUM RIDGE VENT 01/31/2018 Yes Yes N/A N/A 1 Deck -Air— DA-4 Low Profile, Polypropylene Plastic, Roof Vent 07/10/2019 No Yes No +97.5/-97.5 1 0'Hagin's Cloaked Vent Tile Attic Ventilation Product for tile roofing applications 04/04/2018 Yes Yes N/A N/A Mechanically Attached to Plywood Deck. 2 OmniRidge® PRO Vent PR04-N Molded Plastic, Roof Ridge Vent Mechanically 07/1012019 No Yes No +N/A/-165 t Attached to OSB or Plywood Deck. I.r CIO '1. Florida Department of Business &4 Professional Regulation Page 1 of 1 Q Building Codes and Standards 1/9/2017 Product Approval Application Detail ` Florida Department of Business &Professional Regulation Page 1 of 3 FL#15076-R3 r Building Codes and Standards 1/92017 Code Entity o Date Date Date Pend ina Date O r' Tvoe Versio Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status Product Approval Application Detail Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 05/0612015 0412412015 05111l2015 06/23/2015 Approved Florida Department of Business &Professional Regulation Page 1 of t Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 Building Codes and Standards 1/92017 '!" Y SubCategory: Storm Panels tim.robinson@gppent.com FL#7849-R9 Compliance Method: Evaluation Report from a Product Approval Application Detail Florida Registered Architect or a Licensed Florida Code Entity or Date Date Date Pending Date Professional EngineerCZ Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#15088-R1 Revision 2014 Boral Roofing / Monierl-ifetile Thomas Jemmett ICC Evaluation Service, LLC Gary W. Walker 09110/2015 08/25/2015 09/20/2015 Approved FL#15076-R3 Products Category: Roofing (602) 269-2288 (205) 854-0160 Quality Assurance Approved for Use Approved for Use Ig Desian Code Entity or Date Date Date Pending Date SubCategory: Roofing Tiles thomas.jemmett@boral.co Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Type Versio Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status Compliance Method: Evaluation Report m P P 1 20 Gage Galvanized Steel Storm Panels/HVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes N/A Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 04/27l2015 04/24/2015 OS/03/2015 06/23l2015 Approved Product Evaluation Entity or not b tracks to provide hurricane protection. Category: Shutters 954 689-7545 PE-44167 Y P P 9 rY ( ) (954) 772-6224 • FL#7849-R9 Products 2 24 Gage Galvanized Steel Storm Panels/NHVHZ Corrugated Galvanized Steel Storm Panels retained 12131/2017 No Yes Yes N/A SubCategory: Fabric Storm Panel tim.robinson@gppent.com or not by tracks to provide hurricane protection. Compliance Method: Evaluation Report from a Quality Assurance Approved for Use Approved for Use Impact Desian Florida Registered Architect or a Licensed Florida Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15076-R4 Professional Engineer t Code Entity or Date Date Date Pendina Date FL#15088-R! Products ` 13 Saxony 700 -Shake, Slate & Split Shake Flat Profile -Stockton 12/31l2018 No Yes NIA N/A �- a � a f 14 Saxony 900 - Country Slate, Shake & Slate Flay Profile - Henderson 12131/2018 No Yes N/A N/A TTV- ersio Manufacturer Contact Enaineer & License Validated By Validatel Submitted FBC Approval Approved Status Quality Assurance Approved for Use Approved for Use Impact Design 15 Saxony 900 - Country Slate, Shake, Slate & Split Flat Profile - Lake Wales 12/31/2018 No Yes N/A N/A Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 12t2l/2016 12/21/2016 Validated Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure r ' Shake Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 1 GPP FABRIC SHUTTER -SERIES 2000 Coated Polyethylene Fabric Panels retained by tracks 12/3112017 No Yes Yes N/A I:. 16 Saxony 900 - Hartford Slate, Split Old English Thatch, Flat Profile - Stockton 12/31/2018 No Yes NIA N/A SubCategory: Storm Panels tim.robinson@gppent.com or direct mounted to provide hurricane protection. Shake, Slate, Country Slate Compliance Method: Evaluation Report from a 24 Villa 900 Medium Profile - Lake Wales 1213112018 No Yes N/A N/A Florida Registered Architect or a Licensed Florida r ' 25 Villa 900 Medium Profile - Denver 12/31/2018 No Yes N/A N/A Professional Engineer ^ ` G 26 Villa 900 Medium Profile -Stockton 12/3112018 No Yes N/A N/A FL#15076-R4 Products �rjJ y 4 Quality Assurance Approved for Use Approved for Use Impact Desian '.. Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 20 Gage Galvanized Steel Storm Panels/HVHZ Corrugated Galvanized Steel Storm Panels retained 12131/2017 Yes Yes Yes N/A O or not by tracks to provide hurricane protection. 2 24 Gage Galvanized Steel Storm Panels/NHVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 No Yes Yes N/A or not by tracks to provide hurricane protection. O CL l U r Florida Department of Business &Professional Regulation Page 1 or 1 Q Building Codes and Standards 1/9/2017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 2 Florida Department of Business & Professional Regulation Page 1 of 1 1..1.E Building Codes and Standards 1/9/2017 Building Codes and Standards 1/9/2017 V / FL#12856-R5 Product Approval Application Detail Product Approval Application Detail (n Code Entity r Date Date Date Pend Ina Date Type Yj[jj2 Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status FL#17869-RO FL#1999-R5 Revision 2014 Town and Country Industries, Tom Johnston Frank I. Bernardo ORLANDO L. BLANCO, 04/29/2015 04/28/2015 05/04/2015 06/22/2015 Approved Category: Shutters (954) 493-8551 PE-0046549 P.E. Code Entity or Date Date Date Pend Ina Date Code Entity or Date Date Date Pending Date SubCategory: Storm Panels tomi@tc-alum.com (305) 510-8531 Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved status Type Versio Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status Compliance Method: Evaluation Report from a New 2014 All American Shutters and Glass Mike Barbieri Frank L. Bennardo, RE Jorge A. Pomerantz, P.E. 07/03/2015 07fO3/2015 07/10/2015 0a/18/2015 Approved Revision 2014 ITW Building Components Group Inc. / Paslode Stuart Lewis ICC Evaluation Service, LLC William M. Ranieri, PE 03/25/2015 03/20/2015 03/29/2015 Approved ^ Florida Registered Architect or a Licensed Florida Professional Engineer Category: Shutters (561) 712-9882 PE-0046549 (954) 394-8521 Category: Structural Components (847) 918-6473 (407) 681-1917 I..L w . SubCategory: Storm Panels mikeb@allamericanshutte SubCategory: Truss Plates slevds@alpineitw.com FL#12856-R5 Products Compliance Method: Evaluation Report from a rs.com Compliance Method: Evaluation Report from a y, Florida Registered Architect or a Licensed Florida Product Evaluation Entity Quality Assurance Approved for Use Approved for Use Impact Desian Professional Engineer FL#1999R5 Products, Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ-ro Outside HVHZ Resistant Pressure f r FL#17869-RO Products 1 0.050"a Aluminum Storm Panel 0.050" Aluminum Storm Panel with Optional 12/31/2018 No Yes Yes NIA Quality Assurance Approved for Use Approved for Use Impact Design Il-I i Clear Panels Quality Assurance Approved for Use Approved for Use Impact Design Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 ",Safety Edge" Storm Panels ",Safety Edge" Storm Panels, 28ga 12/31/2018 No Yes Yes +54/-54 Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 ITW BCG Higher Strength (H & S) Metal Connector Plate 12/31/2020 Yes Yes N/A N/A (0.018"&quo1;) Steel, 0.022" Alum (Pert 1 22ga, 24ga Steel Panels 22ga, 24ga Steel Storm Panels 12/3l/2017 No Yes Yes N/A 2 ITW BCG Hinge Plate Metal Connector Plate 12/31/2020 Yes Yes N/A N/A Q and Non -Pert) Clear Polycarb (Full and Half) 3 ITW BCG Trulox Metal Connector Plate 12/31/2020 Yes Yes N/A N/A Z J 3 24ga Steel Storm Panel 24ga (0.0232") Steel Storm Panel with Optional 12t3l/2018 No Yes Yes +100/-100 4 ITW BCG Wave Metal Connector Plate 12/31/2020 Yes Yes N/A N/A Clear Panels Z 4 Aluminum Hinged Storm Panel .050" Aluminum Non -Porous Hinged Storm 12131/2018 Yes Yes Yes N/A Panel Q J SHEET NO. .. PA 1.2 r� FL#2197-R5 Code s` TYDe Versio Manufacturer Revision 2014 MiTek Industries, Inc. Category: Structural Components SubCategory: Truss Plates Compliance Method: Evaluation Report from a Product Evaluation Entity FL#2197-R5 Products Sea # Product Model. Number or Name 1 M18SHS 2 Mil 16 3 MT18HS 4 MT20 5 MT20HS FL#1630-R8 Code Type Versio Manufacturer Revision 2014 Weyerhaeuser Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#1630-R8 Products Sea # Product Model. Number or Name 1 TJI 110 2 TJI 210 3 TJI230 4 TJI360 5 TJI560 6 TJI/560D FL#1774-R4 Code Type Versio Manufacturer Revision 2014 Commercial Concrete Products,lnc. Category: Structural Components SubCategory: Products Introduced as a Result of New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#1774-R4 Products Sea # Product Model. Number or Name 1 Quality Precast or Commercial Concrete Products Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Product Approval Application Detail Entity or Date Date Date Pending Date Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status David Wert ICC Evaluation Service, LLC ICC Evaluation Service, 06/30/2015 06/11/2015 07/05/2015 Approved (314) 851-7480 LLC. dwert@mii.00m (205) 599-9800 Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 18 ga. super high strength truss connector plate 12/31/2017 Yes Yes N/A N/A 16 ga. truss connector plate 12/31/2017 Yes Yes N/A N/A 18 ga. high strength truss connector plate 12/3l/2017 Yes Yes N/A N/A 20 ga. truss connector plate 12/3l/2017 Yes Yes N/A N/A 20 ga. high strength truss connector plate 12/31/2017 Yes Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/92017 Entity or Date Date Date Pendina Date Contact Engineer &License Validated By Validated Submitted FBC Approval Approved Status Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 07/06/2015 05/12/2015 07/30/2015 Approved (253)924-4084 (608)839-1344 j i m.anderson2@weyerhae user.com Quality Assurance Approved for Use Approved for Use Impact Desian Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Prefabricated Wood 1-joist 03/31/2017 No Yes N/A N/A Prefabricated Wood 1-joist 03/31/2017 No Yes N/A N/A Prefabricated Wood I -joist 03131/2017 No Yes N/A N/A Prefabricated Wood ]-joist 03/31/2017 No Yes N/A N/A Prefabricated Wood ]-joist 03131/2017 No Yes N/A N/A Prefabricated Wood 1-joist 03/31/2017 No Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity or Contact Enaineer&License Robert Gillis THUY H. HUYNH (813) 659-3707 PE-60122 precastgator@yahoo.com Product Description Precast and Prestressed Concrete Lintels Validated By Florida Engineering Solutions (352) 588-5311 Page 1 of 1 1/92017 Date Date Date Pendina Date Validated Submitted FBC Approval Approved Status 07/03/2015 06/24/2015 08/20/2015 08/26/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Desian Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 05/25/2024 No Yes N/A N/A FL#1644-R4 Code Type Versio Manufacturer Revision 2014 Boise Engineered Wood Products Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#1644-R4 Products Sea # Product Model, Number or Name 1 Versa -Lam Search Criteria FL#6527-R6 Code Tvoe Versio Manufacturer Revision 2014 Weyerhaeuser Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#6527-R6 Products Sea # Product Model. Number or Name 1 iLevel Rim Board 2 Microllam LVL 3 Parallam PSL 4 TimberStrand LSL FL#6527-R7 Code Tvoe Versio Manufacturer Revision 2014 Weyerhaeuser Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#6527-R7 Products Sea # Product Model. Number or Name 1 Microllam LVL 2 Parallam PSL 3 TimberStrand LSL 4 TJ Rim Board 5 Weyerhaeuser Rim Board FL#5450-R5 Code Type ersio Manufacturer Revision 2014 Powers Steel Inc. Category: Structural Components SubCategory: Products Introduced as a Result of New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#5450-R5 Products Sea # Product Model. Number or Name 1 PSbox8LT, PSbox8LT(5-5/8) Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1192017 Entity o Date Date Date Pendina Date Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status Robert Taylor ICC Evaluation Service, LLC APA - The Engineered 05/27/2015 05/06/2015 06/02/2015 Approved (541) 826.0200 Wood Association roberttaylor@bc.com (253) 620-7467 Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Laminated Veneer Lumber 01/01/2035 No Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/92017 Entity or Date Date Date Pendina Date Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 07/06/2015 05/12/2015 07/30/2015 Approved (253) 924-4084 (608) 839-1344 j i m.anderson2@weye rh ae user.com Quality Assurance Approved for Use Approved for Use I Pact Desian Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes N/A N/A board Rim Board Laminated Veneer Lumber 03/31/2017 No Yes N/A N/A Parallel Strand Lumber 03/3112017 No Yes N/A N/A Laminated Strand Lumber 03131/2017 No Yes N/A N/A Entity or Date Date Date Pendina Date Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 10/31/2016 10/25/2016 11/05/2016 Approved (253) 924-4084 (608) 839-1344 ji m.anderson2@weye rhae user.com Quality Assurance Approved for Use Approved for Use Impa Desion Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Laminated Veneer Lumber 03/31/2017 No Yes N/A N/A Parallel Strand Lumber 03/31/2017 No Yes N/A N/A Laminated Strand Lumber 03/31/2017 No Yes N/A N/A Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes N/A N/A board Rim Board Oriented Strand Board Rim Board 03131/2017 No Yes N/A N/A 11 Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity or Contact Enaineer & License William powers Steven W. Schaub (602) 437-1160 PE-60509 bill@powerssteel.com Product Description Powers Steel lintels are field assembled lintels consisting of preformed steel lintels combined with concrete masonry units, grout, and steel reinforcing bars. Validated By SAMUEL A. GREENBERG, P.E, (813) 645-0166 Page 1 of 1 1/92017 Date Date Date Pending Date Validated Submitted FBC Approval Approved Status 03/26/2015 03/23/2015 n30/2015 06/23/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Desian Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 01/27/2017 No Yes N/A N/A FL#1645-R4 Code Type Versio Manufacturer Revision 2014 Boise Engineered Wood Products Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#1645-R4 Products Sea # Product Model. Number or Name 1 AJS Joists FL#158-R7 Code Type Versio Manufacturer Revision 2014 CAST-CRETE USA, Inc. Category: Structural Components SubCategory: Products Introduced as a Result of New Technology Compliance Method: Certification Mark or Listing FL#156-117 Products Sea # Product Model. Number or Name 1 High Strength Concrete Lintels FL#158-RB Code jya Versio Manufacturer Revision 2014 CAST-CRETE USA, Inc. Category: Structural Components SubCategory: Products Introduced as a Result of New Technology Compliance Method: Certification Mark or Listing FL#158-RB Products Sea # Product Model. Number or Name 1 High Strength Concrete Lintels Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/92017 Entity Date Date Date Pendina Cate Contact Engineer & License Validated By Validated Submi a FBC Approval Approved Status Robert Taylor ICC Evaluation Service, LLC APA -The Engineered 05/27/2015 05/06/2015 06/02/2015 Approved (541) 826-0200 Wood Association roberttaylor@bc.com (253) 620-7467 Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Wood "l" Joists 01/01/2035 No Yes N/A N/A Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1192017 Product Approval Application Detail Entity or Date Date Date Pendina Date Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Craig Parrino Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 03/16/2015 02/24/2015 03/18/2015 Approved (813) 621-4641 (786) 315-2590 cparrino@castcrete.com Quality Assurance Approved for Use Approved Use Impact Desian Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 4, 6, 8, and 12 inch wide lintels 05/21/2016 Yes Yes N/A N/A Entity or Date Date Date Pendina DDte. Contact Eno !near & License Validated By Validated dated Submitted FBC Approval Approved Status Craig Perrino Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 05/06/2016 04/29/2016 05/06/2016 Approved (813)621-4641 (786) 315-2590 cparrino@castcrete. com Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 4, 6, 8, and 12 inch wide lintels 05/2112017 Yes Yes N/A N/A O O O U 'O N (D Q O C .CY) CU U (35 C =3 CU O (a (� O C O Q O W O O L.L O CU > •0 — -0 Cn 0 L .� .� C '' ^ VJ Q Q z z W J yi C""""""" O Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Product Approval Application Detail -+—a CU FL#11363-R4 Coe Entity o Date Date Date Pending Date Type Versio Manufacturer Contact Eno ineer&License Validated By Validated Submitted FBC Approval Approved Status — Revision 2014 Powers Steel Inc. William powers Steven Schaub SAMUEL A. 03/26/2015 03/23/2015 03/30/2015 06/22/2015 Approved _ Category: Structural Components SubCategory: Products Introduced as a Result of (602) 437-1160 PE-60509 GREENBERG, P.E, bill@powerssteel.com (813) 645-0166 New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#11383-R4 Products Quality Assurance Approved for Use Approved for Use ImDaCi Desian Seq # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 PowerBOXB Lintels Powers Steel Lintels are field assembled consisting 01101/2017 No Yes N/A N/A of preformed steel lintels combined with brick or concrete masonry units, grout, and steel reinforcing }a bars. ^, W V O O CL CU U) ICU m ri L Ca W Q z J z J d SHEET NO. PA 1.3 a 0 2 9 Ll 2