Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
38965 CR 54 (2)
NORR Project No.: JCDT18-0233-00 Project Info: Bulletin 1 Dollar General 38965 CR 54 Zephyrhills, FL 33542 Project Manager: Laura Long Tel: 313.324.3126 Email: Li3ura.LonL=(a)norr.com File Info: P:\Retail\ Dollar General\ JCDT18-0233 - Zephyrhills FL\ 600-Issues\610-IsSuyd \2019- 06-07 Bulletin 1 F The following items are included,j& this issue: Drawings (06/07/2019) (2) WET SIS sets of drawings (2) Write-ups TRANSMITTAL Date: June 10, 2019 From: Brandi Jackson Tel: 313.426.9672 Email: B,randi.lackson itnorr.conl. Distribution: Building Department Phone: (813)780-0020 Zephyrhills Building Department 5335 81h Street Zephyrhills, FL 33542 Priority Overnight JCDT18-0233-00 i i NORR, LLC 150 W. Jefferson Avenue, Suite 1300 T 313 324 3100 Detroit, MI 48226 F 313 324 3111 An Engenium Group Company U.S.A. norr.com Al 49, NORM nn ARCHITECTS ENGINEERS PLANNERS Reason for Issue Date Bulletin 01 June 7, 2019 Project Information NORR Project No. Dollar General Zephyrhills, FL JCDT18-0233-00 Intent REVISION WRITE-UP This TRANSMITTAL is issued to provide new and/or updated project documents. Drawings The following 15RAWINGS accompany and form a part of this TRANSMITTAL. ARCHITECTURAL Revised Drawings: CS, F1, Al, A9 r tf ur;`a.: 1 �� ELECTRICAL°It I� 1,4; . Revised Drawings: E1, E5 ARCHITECTURAL DRAWING REVISIONS 1. Dwg No CS a. Index has been updated to reflect current issuance. b. Revised the National Account Vendors list as per technical bulletin TB19-003 updates. C. Revised Prototype "E" release date as per technical bulletin TB19-003 updates. 2. Dwg No F1 a. Revised fixtures, coolers, freezers and dimensions as per technical bulletin TB19-004 Reissue. b. Relocated equipment out of access ramps for handicap parking. 3. Dwg No Al a. Revised fixtures, coolers, freezers and dimensions as per technical bulletin TB19-004 Reissue. b. Revised note 9 as per technical bulletin TB19-004 Reissue. 4. Dwg No A9 a. Added notes to cable tray plan as per technical bulletin TB19-003 updates. ELECTRICAL DRAWING REVISIONS 1. Dwg No E1 a. Revised the location of (4) power drops in the Sales Area. Printed: Last printed 10/06/2019 1:52 PM (DOI: 04.04.2005) REVISION WRITE-UP (Continued) Page 2 b. Moved the location of the Gatorade cooler receptacles. C. Deleted the receptacles for the freezer and cooler line-up and indicated junction boxes. Contractor shall wire the cases directly from the junction boxes. d. Revised the Legend. e. Revised Electrical Specification 'N". f. Revised the location of the exterior ice storage receptacle. g. Added Key Note # 11. h. Added a cold drink cooler on the South wall near the front entrance. i. Added a 2 door stand alone cooler in the Receiving Area. j. Added a 2 door stand alone freezer in the Receiving Area. 2. Dwg No E5 a. Revised the schedules for Panel 'A' and Panel W. b. Revised the Load Schedule. Printed: Last printed 10/06/2019 1:52 PM (DOI: 04.04.2005) NORR REVISION WRITE-UP ARCHITECTS ENGINEERS PLANNERS Reason for Issue Date Bulletin 01 June 7, 2019 Project Information NORR Project No. Dollar General Zephyrhills, FL JCDT18-0233-00 Intent This TRANSMITTAL is issued to provide new and/or updated project documents. Drawings The following DRAWINGS accompany and form a part of this TRANSMITTAL. ARCHITECTURAL Revised Drawings: CS, F1, Al, A9 ELECTRICAL Revised Drawings: E1, E5 (Lrr'ti ox z y..._..,. ARCHITECTURAL DRAWING REVISIONS 1. Dwg No CS a. Index has been updated to reflect current issuance. b. Revised the National Account Vendors list as per technical bulletin TB19-003 updates. C. Revised Prototype "E" release date as per technical bulletin TB19-003 updates. 2. Dwg No F1 a. Revised fixtures, coolers, freezers and dimensions as per technical bulletin TB19-004 Reissue. b. Relocated equipment out of access ramps for handicap parking. 3. Dwg No Al a. Revised fixtures, coolers, freezers and dimensions as per technical bulletin TB19-004 Reissue. b. Revised note 9 as per technical bulletin TB19-004 Reissue. 4. Dwg No A9 a. Added notes to cable tray plan as per technical bulletin TB19-003 updates. ELECTRICAL DRAWING REVISIONS 1. Dwg No E1 a. Revised the location of (4) power drops in the Sales Area. Printed: Last printed 10/06/2019 1:52 PM (DOI: 04.04.2005) REVISION WRITE-UP (Continued) Page 2 b. Moved the location of the Gatorade cooler receptacles. C. Deleted the receptacles for the freezer and cooler line-up and indicated junction boxes. Contractor shall wire the cases directly from the junction boxes. d. Revised the Legend. e. Revised Electrical Specification 'N". f. Revised the location of the exterior ice storage receptacle. g. Added Key Note # 11. h. Added a cold drink cooler on the South wall near the front entrance. i. Added a 2 door stand alone cooler in the Receiving Area. j. Added a 2 door stand alone freezer in the Receiving Area. 2. Dwg No E5 a. Revised the schedules for Panel 'A' and Panel 'B'. b. Revised the Load Schedule. Printed: Last printed 10/06/2019 1:52 PM (DOI: 04.04.2005) REQUIRED NATIONAL ACCOUNT VENDORS COMPANY CONTACTS PHONE # REQUIRED ITEMS W RAINBIRD IRRIGATION LOCAL RAIN BIRD DISTRIBUTER WWW.RAINBIRD.COM IRRIGATION SYSTEMS U) W WO EUCLID CHEMICAL PHIL BRANDT 877-438-3826 CONCRETE POLISHING SYSTEMS of Z W_ COMPANY PBrandt@euclidehemical.com Z z � RETRO-PLATE SYSTEMS SCOTT MAXFIELD 801-641-6796 CONCRETE POLISHING SYSTEMS O 00 scott.maxfield@retroplatesystem.com RECORD DOOR SYSTEMS S S -MARK COLLADO - 704-290 0237 Y MD MODEL #5100 SERIES IN,K , dollargeneral@recorddoors.com OH, PA,VA,WV 0111 STANLEY ACCESS MATTHEW D. MATTHEWS 919-208-4238 AR,AZ,CA,CO,CT,DE,IL,IA,KS,LA,MA,ME,MI,MN,MO, MODEL #DG2000 w Z TECHNOLOGIES matt.matthews@sbd'inc.com ND,NE,NH,NJ,NM,NV,NY,OK,OR,RI,SD,TX,VT,WA,WI,WY o z ASSA ABLOY ENTRANCE ROSS MERKLING 609-528-2580 AL, FL, GA, MS, NC, SC, TN MODEL #SL500 cn w SYSTEMS dollargeneral.besam.us@assaabloy.com GIRTMAN AND ASSOCIATES JUNE THOMPSON 615-964-6000 ext. 4527 INTERIOR DOORS AND FRAMES AL,AR,AZ,CA,CO,FL,GA,IA,KS,LA,MS,MN,MO, U, o u, dgconstruction@bass-security.com AND RESTROOM ACCESSORIES NE,NM,NV,OK,OR,SC,SD,TN,TX,WA,WI,WY o0� w COOK & BOARDMAN GROUP JOE HARRELL 336-837-0673 INTERIOR DOORS AND FRAMES CT,DE,IL,IN,KY,MA,MD,ME,MI,NC,NH,NJ, o Z O nationalsales@cookandboardman.com AND RESTROOM ACCESSORIES NY,OH,PA,RI,VA,VT,WV w SHERWIN WILLIAMS LOCAL SHERWIN WILLIAMS STORE PAINT, PRIMER, CONCRETE SEALER AND BLOCK FILLER MC CUE CORPORATION KEVIN O'NEILL 678-492-4026 koneill@mccue.com TRIM KIT INCLUDES BUMPER GUARDS AND CART STOP zLn YORK NATIONAL ACCOUNTS 800-481-9738 HVAC UNITS york-dollargeneral-be@jci.com AR, CO, IL, IN, KY, KS, MO, OH, OK, WV, WY CARRIER HASAN KHALIL 315-432-7655 HVAC UNITS Hasan.Khali@carrier.utc.com CT, IA, MA, ME, MI, MN, ND, NE, NH, NJ, NY, PA, RI, SD, VT, WI z LENNOX SCOTT MACDONALD 972-497-6781 HVAC UNITS _ dollargeneral@lennoxind.com AL, AZ, CA, DE, FL, GA, LA, MD, MS, NC, NM, NV, OR, SC, TN, TX,VA, WA ROOF CURB SYSTEMS CLIFTON REASOR 800-683-5848 RTU CURB DollarGeneral@roofcurb.com CURBS PLUS INC. ALLAN THRAILKILL 888-639-2872 RTU CURB alan.thrailkill@curbs-plus.com KCC INTERNATIONAL INC. GREG CONRAD 800-382-2872 RTU CURB _ w o gconrad@kcccurbs.com Q CED - CONSOLIDATED ROBERT DECKER 270-781-2229 ELECTRICAL SWITCH GEAR AR,AZ,CA,CO,IA,IN,IL,LA,KS,KY,MI,MN,MO, _ ELECTRICAL DISTRIBUTORS robertd@cedbgky.com MS,ND,NE,NM,NV,OK,OR,SD,TX,WA,WI,WY W � w NESCO CHRIS TRACY 800-244-6980 ELECTRICAL SWITCH GEAR AL,CT,DE,FL,GA,MA,MD,ME,NC,NH,NJ, w rn (D dollargeneral@needhamelectric.com NY,OH,PA,RI,SC,TN,VA,VT,WV USLED JORGE HERRERA 713-337-3826 ELECTRICAL LIGHTING AR,CO,IA,IL,IN,KS,KY,MI,MN,MO, Z PAUL JEZIOROWSKI DGUSLED@usled.com SUPPLIES ND,NE,OH,OK,SD,WI,INV,WY _ LEDS MICHAEL STRINGER 920-915-4010 ELECTRICAL LIGHTING AL,AZ,CA,CTDE,FL,GA,LA,MA,MD,ME,MS,NC, J KYLE KNAPP DGORDERS@Ieds-llc.com SUPPLIES NH,NJ,NM,NV,NY,OR,PA,RI,SC,TN,TX,VA,VT,WA D&P CUSTOM LIGHTING NATIONAL ACCOUNT SALES 800-251-2200 CUSTOM POWER POLES CROSSCOM NATIONAL KEN MILLER 847-850-6298 LOW VOLTAGE & VOICE/DATA CO,CT,DE,FL,IA,IL,IN,KS,MA,MD,ME,MI,MN,MO, Qw dollargeneral@crosscomnational.com ND,NE,NH,NJ,NY,OH,PA,RI,SD,VT,WI,WV,WY ASD CHRIS RUDN'ITSKI 828-624-1046 LOW VOLTAGE & VOICE/DATA AL,AR,AZ,CA,GA,KY,LA,MS,NC,NM,NV, o U) crudnitski@asd-usa.com OK,OR,SC,TN,TX,VA,WA GRAYBAR JEROME BANNISTER 615-743-3202 office, 615-924-2135 cell CABLE TRAY DoilarGeneral@graybar.com EMERSON CLIMATE WEBSITE: USER NAME: dollargeneralbid EMS SUPPLIER NOTE: CUSTOMIZED DOLLAR GENERAL EMS PANEL REQUIRES TECHNOLOGIES http://dol'largeneralbid.ectsolutions-.net PASSWORD; dollargeneralbid STORE #, CITY, STATE, ZIP CODE & QTY. OF HVAC UNITS OF THE INSTALL SITE Q U WHEN ORDERING. STANLEY CONVERGENT D'ETTA NEAVES 858-752-7821 INTERIOR FIRE ALARM PANELS SECURITY SOLUTIONS Detta.Neaves@sbdinc.com (pre -sale bid) w AI,Maier@sbdinc.com (post -award) RECOMMENDED NATIONAL ACCOUNT VENDORS PRE-ENGINEERED METAL BUILDING COMPANY CONTACTS PHONE # VP BUILDINGS DAVID ENGLISH 901-568-4537 PRE-ENGINEERED METAL BUILDING DEnglish@vp.com STAR BUILDING SYSTEMS JEFF HORN 866-664-8899 PRE-ENGINEERED METAL BUILDING NUCOR BUILDING SYSTEMS BOB BARRY 315-622-4440 PRE-ENGINEERED METAL BUILDING CORPORATE: 260-837-7891 https://www.formrouter.net/forms@MBSIN/dgquote.pdf BIG BEE STEEL BUILDINGS, INC. KEVIN BUSLER 800-633-3378 PRE-ENGINEERED METAL BUILDING CHIEF BUILDINGS ERIN SULLIVAN 308-385-4628 PRE-ENGINEERED METAL BUILDING erin.sullivan@chiefind.com IRRIGATION''a z -q�:s COMPANY CONTACTS ��_'•�C RAIN BIRD IRRIGATION LOCAL RAIN BIRD DISTRIBUTER WWW.RAINBIRD.COM IRRIGATION SYSTEMS REQUIRED NATIONAL ACCOUNTS FOR ENGINEERING AND CONSTRUCTION MATERIAL TESTING COMPANY CONTACTS PHONE # ATC ASSOCIATES, INC. LESLIE GREENWOOD 205-733-8775 www.atGassociates.com leslie.greenwood@atcgc.com BUILDING AND EARTH MATT ADAMS 205-836-6300 www.buildingandearth.com SCIENCES, INC. dollargeneral@buildingandearth.com EAS PROFESSIONALS, INC. JERRY MARRONE 864-234-7368 www.eas-pro.com dollargeneral@eas-pro.com PROFESSIONAL SERVICE TERESA HEBNER 770-424-6200 #3030 www.psiusa.com INDUSTRIES, INC. (PSI) teresa.hebner@psiusa.com TERRACON JOHN MEADOW 770-623-0755 #353 www.terracon.com dollargeneral@terracon.com NOTE: MATERIAL TESTING IS REQUIRED ON ALL TRIPLE NET LEASES. PROTOTYPE MANAGEMENT TEAM COMPANY CONTACTS PHONE # MJM ARCHITECTS GARY CONWAY 615-244-8170 www.mjmarch.com dg@mjmarch.com ENTECH MITCH SIMPSON 615-373-2640 www.entechtn.com email@entechtn.com NATIONAL ACCOUNT & CONTACT INFORMATION SUBJECT TO CHANGE i i . C T E.... ... a f. . I . _ 1 _ ( l I l �_ C - _[ � _ _ 1 _ 1 _C f . [ 1 C C ( E i 3 T ) f I )DOLLAR Store # 20360 ) ) )38965 CR 54, Zephyrhills, Florida 33542 " 11(Left )Based on 9 100 SF Protot e ECorner Entry, Right Side Deliver � p y� R g y) )release date: 0 3 / 2 8 / 2 019 Product Approval Information Sheet Froiect Name.: Dollar General - Zephyrhills; (City of Zephyrhills), FL Protect Address: 38965 CR 54 02 As required by Florida Statute 553.842 and Florida Administrative Cade 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed 1 above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed / products. Information regarding statewide product approval may be obtained at: www.flondabuildind.oro- J � Z O a Z ZLU H 0 Z w w V) f_ O O U M m Q m O w a w a ■ ■ ■ ■ ■ ■ Category Manufacturer Product Description Limitation of Use Product Approval A. Exterior Doors GENERAL Swinging; Curries Doors Outswing commercial Steel'' Approved for use in +60 / -60 FL 8394.1 - R5 Door HVHZ psf (Pair) (Pair) +80 / -80 FL 8394.3 - R5 psf (Single) (Single) • Category Manufacturer Product Description Limitation of Use Product Approval A. Exterior Doors CS COVER SHEET Automatic Assa Abloy Entrance Besam Resilience Full Breakout Approved for use in +70i-70 FL 16128.1- R3 Systems US Inc__ Bi-part Large and Srrrail lvlisste HVHZ Impact Door System. r OWNER: Category Manufacturer Product Description Limitation of Use Product Approval F1 FIXTURE PLAN / LIFE SAFETY PLAN C. Cladding EIFS Dryvit System EIFS over 518" Sheathing, for Approved for use in +110 /-110 FL2030.5- less than 30 feet HVHZ psf R10 D.walls Storefront ARCHITECTURAL: St 00131100 111111111311 01111111111 INNNNN 011011110 00111100 Storefront lfawneer Series "IR-500 Flush and Wet Approved for use in +65 f -85 FL 8787.2 - R5 Glazed" Aluminum Storefront HVHZ psf System - L. M. [. A00 ARCHITECTURAL SITE DETAILS Al FLOOR PLAN E. Metal BuildingManufacturer PEMB A2 EXTERIOR ELEVATIONS A3 SECTIONS AND DETAILS Metal Wall Panels Nucor Building Reverse Classic Wall Panel Not approved for +45.0 / FL 2686.3 - Rb Systems use in HVHZ -45 psf Roof Deck Nucor Building CFR Panel Not approved for +N/A FL 4890.1 - R8 Systems use in HVHZ -108-8 psf A3a SECTIONS AND DETAILS In addition to completing the above list of manufacturers, product description and State approval number of the products used on this A3b SECTIONS AND DETAILS project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions, A4 ROOM FINISH SCHEDULE AND along with the list above, on the job site available to the inspector. SALES FLOOR ELEVATIONS A5 DOOR SCHEDULE AND DETAILS A6 ENLARGED PLANS AND TOILET ROOMS A7 SIGN DETAILS A8 SIGN BRACING DETAILS A9 REFLECTED CEILING PLAN A10 WALL TYPES A11 GENERAL NOTES Al2 ARCHITECTURAL SPECIFICATIONS i ) STRUCTURAL: 1 S1 STRUCTURAL GENERAL NOTES -57 psf S2 FOUNDATION PLAN AND SCHEDULES S3 FOUNDATION SECTIONS AND DETAILS S4 SECTIONS AND DETAILS S5 CONCRETE SUMMARY STRUCTURE IS NOT LIGHT FRAME r TRUSS CONSTRUCTION MECHANICAL: MINIM101 I M1 HVAC LAYOUT M2 HVAC SCHEDULES / NOTES / DETAILS PLUMBING: NONE P1 PLUMBING PLANS AND SCHEDULE P2 PLUMBING DETAILS AND DIAGRAMS ELECTRICAL: ❑❑❑❑❑■ ■❑❑❑❑■ ■■❑❑❑■ ■■❑❑❑■ ❑■❑❑❑■ ■■❑❑❑■ ■■❑❑❑■ ■❑❑❑❑■ ■❑❑❑❑■ 0■❑❑❑■ E1 POWER PLAN E2 LIGHTING PLAN E3 POWER POLE AND POWER TERMINAL DETAILS E4 CABLE TRAY LAYOUT PLAN E5 THREE PHASE ELECTRICAL PANELS EMS1 EMS / LOW VOLTAGE PLAN EMS2 CPU TERMINAL DIAGRAM ES1 ELECTRICAL SITE LIGHTING AND POWER PLAN ES2 SITE LIGHTING PHOTOMETRICS PLAN ES3 SITE LIGHTING FIXTURE CUT SHEETS `0 \O' 1 3 2 3 O 2 O 2 O 3 2 3 O O O O a=7'-0' TYP 130'-8" BUILDING MUST COMPLY WITH ALL BUILDING (FEDERAL, STATE AND LOCAL), FIRE, ADA AND HEALTH DEPARTMENT CODES. METAL BUILDING COLUMNS SHALL BE STRAIGHT. COLUMNS AND INTERIOR COLUMNS MAY REQUIRE WRITTEN APPROVAL. MAINTAIN INTERIOR CLEARANCE BETWEEN FACE OF COLUMN'S AND SALES FLOOR AS NOTED ON PLANS PROTECT OPENINGS NOTE: ALL NEW FIRE WALLS REQUIRED TO PREVENT THE PASSAGE OF SMOKE AND FIRE SHALL BE IDENTIFIED WITH WORDING "FIRE AND SMOKE BARRIER -PROTECT OPENINGS PER NFPA 101 :8.3.2.4 LIGHT FRAME TRUSS NOTE: THIS PROJECT DOES NOT USE LIGHT FRAME TRUSS CONSTRUCTION CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 12/18/2018 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 06/07/2019 BULLETIN 01 02 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILI S-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title COVER SHEET DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 CS [Ic C Al fA E L E R El LI rw ESM-10 VR-10 COKEN @__u__ E PEPSI PEPSI TG1 A - SERVICE COUNTER PLAN B - ELEVATION SERVICE COUNTER DETAILS FIXTURE PLAN Scale: 1/4" = V-0" NOTE: FRONT CHECKOUT COUNTER TO BE PROVIDED BY DOLLAR GENERAL AND INSTALLED AT DOLLAR GENERAL'S DIRECTION. COUNTERS SHALL INCLUDE A PORTION OF AT LEAST 36" IN LENGTH WHICH IS NO MORE THEN 34" ABOVE THE FINISH FLOOR. COUNTERS SHALL BE ON AN ACCESSIBLE ROUTE. HECK WRITING SURFACE NORTH LIFE SAFETY PLAN Scale: 3/16" = V-0" BUILDING CODE COMPLIANCE BUILDING CODE V 2017 FLORIDA BUILDING CODE 5th EDITION 2017 FLORIDA FIRE PREVENTION CODE 5th EDITION 2017 FLORIDA PLUMBING CODE 5th EDITION 2017 FLORIDA MECHANICAL CODE 5th EDITION 2014 NFPA 70 NATIONAL ELECTRIC CODE 2017 FLORIDA ACCESSIBILITY CODE (CHAPTER 1 1) 5th EDITION 2017 FLORIDA ENERGY CODE (CHAPTER 1 3) 201 5 NFPA 101 LIFE SAFETY CODE OCCUPANCY (M) MERCANTILE (S 309) (S-2) STORAGE, SEPARATED (S 31 1 .3) CONSTRUCTION CLASSIFICATION II-B NON-SPRINKLERED (T 601) MIN INTERIOR FINISH CLASS 'C' (T 803.11) BASE HEIGHT & AREA LIMITATIONS MAX HEIGHT- STORIES = 2 STORIES (T 504.4) MAX HEIGHT- FEET = 55 FEET (T 504.3) MAX ALLOWABLE AREA PER FLOOR (Aa) = 12,500 SQ FT (T 506.2) Aa=112,500 + [12,500 x 0]] = 12,500 ACTUAL BUILDING PROPERTIES ACTUAL AREA = 9,100 SQ FT ACTUAL HEIGHT (OVERALL) = 21'-4" FIRE RESISTANCE RATING REQUIREMENTS (T 601) STRUCTURAL FRAME = 0 HR BEARING WALLS- EXTERIOR = 0 HR BEARING WALLS- INTERIOR = 0 HR NON -BEARING WALLS- EXTERIOR = 0 HR NON -BEARING WALLS- INTERIOR = 0 HR FLOOR CONSTRUCTION = 0 HR ROOF CONSTRUCTION = 0 HR DESIGNED OCCUPANT LOAD (T 1004.1 .2) SALES FLOOR (7,298 sf/ 30) = 244 OCCUPANTS BREAK ROOM and OFFICE 0 47 sf/ 100) = 2 OCCUPANTS TOILET ROOMS and HALL (249 sf/ 100) = 3 OCCUPANTS RECEIVING (990 sf/ 300) = 4 OCCUPANTS TOTAL OCCUPANT LOAD = 253 OCCUPANTS EGRESS REQUIRED/ PROVIDED: # EXITS REQUIRED AND PROVIDED: GROUND 2 REQ'D / 3 PROVIDED (T 1006.3.1) EXIT WIDTH REQUIRED 0.20"/ PERSON EXIT CAPACITY REQUIRED = 50.4" EXIT CAPACITY PROVIDED = 1 70" (S 1005.3.2) MAXIMUM LENGTH OF EXIT ACCESS TRAVEL NOT TO EXCEED "M' = 200'-0" (T 1017.2) ACTUAL MAX. TRAVEL DISTANCE = 1 1 7 4' PLUMBING FACILITIES REQUIRED: (T 403.1) PLUMBING FACILITIES PROVIDED: WATER CLOSET LAVATORY OCCUPANTS WATER CLOSET LAVATORY EA, SEXREQ'D REQ'D PROV'D NON -GENDER 126 1 per 500 1 per 750 UNISEX 1 1 NON -GENDER 126 1 per 500 1 per 750 UNISEX 1 1 DRINKING FOUNTAIN 1 PER 1000 (1) SERVICE SINK PROVIDED (1) HIGH/LOW DRINKING FOUNTAIN PROVIDED EMERGENCY LIGHT W/ BATTERY BACKUP X\ ( + LIGHTED EXIT SIGN W/ BATTERY BACKUP DENOTES PATH OF EGRESS REMOTENESS BETWEEN EXITS DIAGONAL DIMENSIONS = 144'-0" SEPARATION OF EXITS = 144'-0" _ 2 = 72'-0" ACCTUAL DISTANCE BETWEEN EXIT DOORS IS: 104'-8" DENOTES 2A1 OBC FIRE EXT. W/ TOP @ +42" A.F.F. F.E. MAXIMUM 75 FEET TRAVEL DISTANCE TO REACH FIRE EXTINGUISHER CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 12/1 8/2018 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM Ol 06/07/2019 BULLETIN 01 02 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title FIXTURE PLAN / LIFE SAFETY PLAN DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.02 3 3 F1 11 1 T11 1 1 - - ----ram DRINK FIXTURE WALL MOUNTING SUPPORT NOTES: 1. PROVIDE AND INSTALL 2X6 WHITE PINE - GRADE 2 OR BETTER. 2. PROVIDE AND INSTALL 2X4 WHITE PINE - GRADE 2 OR BETTER. 3. FASTEN THE 2X6 TO THE WALL WITH THE TOP EDGE OF THE BOARD AT 78" A.F.F., STARTING FROM THE END OF THE LAST COOLER AND STOPPING 5'-0" FROM REAR WALL. 4. FASTEN THE 2X4 TO THE WALL WITH THE TOP EDGE OF THE BOARD AT 12"A.F.F., STARTING FROM THE END OF THE LAST COOLER AND STOPPING 5'-0" FROM REAR WALL. 5. PRE -DRILL PILOT HOLES IN ALL BOARDS PRIOR TO INSTALLATION TO PREVENT WOOD SPLITS. 6. SECURE THE 2X6 WITH THREE SELF -TAPPING SCREWS PER WALL STUD. MINIMUM SCREW SIZE IS 4"x 4". 7. FASTEN THE 2X4 WITH WITH ONE SELF -TAPPING SCREW PER WALL STUD. MINIMUM SCREW SIZE IS 4"x4, . 8. CAULK THE EDGES OF THE 2X6 AT THE TOP AND BOTTOM WHERE IT MEETS THE WALL PRIOR TO PAINTING. 9. PRIME AND PAINT BOTH BOARDS TO MATCH WALL COLOR. LINE OF FREEZER _ COOLERS BEYOND II I I � II II II e II II II (FIXTURE IJPPLIED Al b ll I INSTALLE BY DOLLA GENERAL( I IIMERCHANRISING II A IIDEPARTM�INT II II II II If II II ff II II w II II II II II II CONTRACTOR TO (PROVIDE D INSTAL 12x4 WHIT :'INE GRA r l ©� � 20RBET R I II III II II I CONTRACTOR TO PROVIDE AND INSTALL 2x6 WHITE PINE GRADE 2 OR BETTER II II II II II II II II II I II II II fI II II II II CONTRACTOR TO I I INSTALL( �x WOOD FRAM IN TO ALLOW I I HORIZO AL ANCH �IO R BOARD RUN I I CONTIN I OUSLY PAIF I I PEMB C ILUMNS II II II II II II if II II II II II �' � I I LI II II � II II II I � If II II II Il II VERIFY ANCHOR BOARDS LOCATION WITH FIXTURE PLAN 2 ANCHOR BOARD DETAIL NTS 5 T6 WALL TYPES LEGEND SEE SHEET Al 0 FOR ADDITIONAL NOTES AND DETAILS WALL TYPE (I.E. FULL HEIGHT) 04 T_ INTERIOR FACE OF PEMB FRAMING BEYOND ANCHOR BOARD: CONTRACTOR TO PROVIDE AND INSTALL 2x6 WHITE PINE GRADE 2 OR BETTER TOP OF FIXTURE TO BE AFFIXED TO DRIED PINE NAILER BY DOLLAR GENERAL MERCHANDISING DEPT FIXTURE SUPPLIED & INSTALLED BY DOLLAR GENERAL MERCHANDISING DEPT MTL LINER PANELS CONTRACTOR TO INSTALL VERTICAL 2X WOOD FRAMING SO THAT HORIZONTAL ANCHOR BOARDS RUN CONTINUOUSLY PAST PEMB COLUMNS ANCHOR BOARD: CONTRACTOR TO PROVIDE AND INSTALL 2x4 WHITE PINE GRADE 2 OR BETTER FINISHED FLOOR EIFS BULLNOSE EIFS PILASTER (REF " 1'4" 1'-4" EXTERIOR ........ .... - ELEVATIONS) 5/8" EXTERIOR GRADE _ � '� COk GYPSUM BOARD SHEATHING ON METAL cD WALL PANELS VINYL FACED R-13 BATT INSULATION + R-6.5 R-6.5 METAL BUILDING COLUMNS CONTINUOUS INSULATION SHALL BE STRAIGHT. TAPERED WITH VAPOR BARRIER (BY COLUMNS &INTERIOR COLUMNS PEMB). REQUIRE WRITTEN APPROVAL. "EWH-2" MAINTAIN INTERIOR CLEARANCE WATER HEATER ON 1/2" GYP BOARD OVER LINER C01 OF 68'-0" BETWEEN FACE OF SHELF ABOVE MOP SINK PANELS - REFER TO INTERIOR COLUMNS ON SALES FLOOR ELEVATIONS FOR LOCATIONS MCP SINK (BELOW) DETAIL @COLUMN ABOVE BULLNOSE THIS � 3 FAUCET WALL T-0" OF 48" HIGH FRP DEFS ON 4" CMU 1'-4" 1'4" ALUMINUM CORNER PILASTER (REF EXTERIOR —.GUARDS ELEVATIONS) _ 8'-0" WING WALL bo DOORSTOP T-0" 4" 4 METAL BUILDING COLUMNS 8" CMU (REF EXTERIOR SHALL BE STRAIGHT. TAPERED ELEVATIONS) INTERIORCOLUMNS & REF. REQUIRE WRITTEN APPROVAL. 1/2" GYP BOARD OVER LINER STRUCTURAL MAINTAIN INTERIOR CLEARANCE PANELS - REFER TO INTERIOR COI OF 68'-0" BETWEEN FACE OF ELEVATIONS FOR LOCATIONS COLUMNS ON SALES FLOOR DETAIL @ COLUMN BELOW BULLNOSE 4 A2i 3�i 2 �! I 1 1 FLOOR PLAN Scale: 1/8" = V-0" ABOVE 4'-0" 1 3/4" = P-0" I MOP HOLDER i 1 i �:5'-O" OF 48" HIGH FRP '61 5 ENLARGED PLAN_ DETALL SEE 4/P2 ALSO NTS FLOOR PLAN KEYED NOTES RECEIVING DOOR BUZZER (TORK MDL.#TA725 OR EQUAL) 2" DOOR SCOPE (REF DOOR SCHEDULE SHEET A5) WEATHER STRIP & LOW PROFILE THRESHOLD (REF DOOR SCHEDULE SHEET A5) STRIPE FLOOR AT RECEIVING DOOR AS INDICATED FOR DESIGNATED EGRESS PATH (PAINT YELLOW) AND DESIGNATE 3'-0" EMS PANEL CLEARANCE (PAINT RED) 4A STRIPE FLOOR FOR DESIGNATED ADA EGRESS PATH (PAINT YELLOW) PROVIDE AND INSTALL WATER HEATER ABOVE THE MOP SINK (REF 5/A1 AND 3/P1) BEAUTY AND COSMETICS SHELVING AND EQUIPMENT. METAL LINER PANELS COORDINATE FULL HEIGHT PANELS W/ FURRING @ CMU WEST WALL FOR FLUSH FINISH CART AREA. REFER TO 5/A06 02 J-BOXES - SEE ELECTRICAL FOR DETAILS. 10 CONCRETE SLAB ON VAPOR BARRIER (REF STRUCTURAL SHEET S2) METAL BUILDING FRAME REFER TO NOTED WALL SECTION FOR ADDITIONAL INFORMATION 1/2" GYP BOARD OVER LINER PANELS W/ R-13 BATT 2 INSULATION. METAL LINER PANELS TO DECK ABOVE; GYPSUM BOARD TO RUN TO 10'-0" AFF, PAINTED. ROOF MOUNTED HVAC UNITS - COORDIANTE PAD 13 DIMENSIONS WITH HVAC UNITS (REF CIVIL PLAN AND SHEET M1) BROOM FINISH CONCRETE SIDEWALK - SLOPE }4 CONCRETE AWAY FROM BUILDING (TYP) - (COORDINATE WITH CIVIL PLANS). 15 EIFS PILASTER (REF EXTERIOR ELEVATIONS) 6 STOREFRONT SYSTEM (REF SHEETS A5) 1 7 LINE OF CANOPY ABOVE 18 A.D.A. COMPLIANT H.C. RAMP. (REF CIVIL PLANS) CART AND BUMPER GUARDS 4" A.F.F 9 MC CUE PART #9014 TRIMKIT) (REF 5/A6) WALL HYDRANT (REF PLUMBING SHEET P1 2Q FOR ADDITIONAL INFORMATION) 21 REFRIGERATION BY DOLLAR GENERAL STEEL COLUMN. PAINT SW7005 PURE WHITE. WRAP 22 STEEL COLUMN WITH TIGHT LOOP CARPET(BLACK) FROM BASE TO 48" A.F.F. 23 POWER POLE. COORDINATE FINAL LOCATION WITH ELECTRICAL DRAWINGS FLOOR ARE AT BASE OF COLUMN WITHIN THE 24 CONSTRUCTION JOINTS TO BE PAINTED BLACK MAGIC TINT ENDCAP COOLER/FREEZER TO BE HARDWIRED THROUGH WHITE SO CORD. GC TO LEAVE BOTTOM 25 HANGING AT 80" AFF. (REF. ELECTRICAL) CORD ANCHORED TO PURLINS ABOVE. COORDINATE LOCATION WITH FINAL DOLLAR GENERAL FIXTURE PLAN. BEAUTY STATION TO BE HARDWIRED THROUGH WHITE SO CORD. GC TO LEAVE BOTTOM HANGING AT 48" 25A AFF. (REF. ELECTRICAL) CORD ANCHORED TO PURLINS F ABOVE. COORDINATE LOCATION WITH FINAL DOLLAR GENERAL FIXTURE PLAN. 26 PRE -FINISHED METAL DOWNSPOUTS (COORDINATE H SIZE AND LOCATIONS WITH PEMB AND CIVIL PLANS) MG CUE RAILING IN FRONT OF ELECTRICAL PANELS 27 8'-0" LONG WITH TOP TWO RAILINGS AND NO MIDDLE POST. 8" SMOOTH -FACED CMU PAINTED (REFER TO EXTERIOR 28 FINISHES ON SHEET A2). ALIGN FACE OF BLOCK WITH STEEL GIRT. PROVIDE PROPER ANCHORAGE TO STRUCTURE. CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 1 2/1 8/2018 PERMIT SUBMITTAL 01 /1 1 /201 9 OWNER REVIEW 02/07/2019 BID SET 03/04/201 9 ADDENDUM 01 06/07/2019 BULLETIN 01 02 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title FLOOR PLAN DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 Al 1" CONDUIT EMS PANEL BELOW — RECEIVING AREA 103 GRAPHIC UNISTRUT 10' LONG TO BE CENTERED ON ENDCAP AT 11' 0"A.F.F. ON THREADED ROD. S CLOSE TO BACK AS POSSIBLE. UNISTRUT MOUNTED FLATSIDE DOWN. 116'-2 112" SALES AREA 102 G.C. TO PROVIDE SPrAKER WIRE IN CABLE TRAY FOR DG'S SPEAKERS GRAPHIC UNiS RUT 10' LONG TO BE CENTERED ON ENDCAP AT 1 V-0" A.F.F. ON THREADED ROD. AS CLOSE TO BACK AS POSSIBLE. UNISTRUT MOUNTED FLAT SIDE DO' N. **PRE -PUNCHED 1 1/4" GALVANIZED ANGLES ARE APPROVED EQUAL TO UNI-STRUT GRAPHIC UNISTRUT 10' LONG TO BE CENTERED ON AUTOMATED DOORS AT 1 V-0" A.F.F. ON THREADED ROD. UNISTRUT MOUNTED FLAT SIDE DOWN. 15'-8" Cl? CABLE TRAY NOTE: GC SHALL PROVIDE AND INSTALL WHITE 6 CABLE TRAY LINER 4 3 2 � CABLE TRAY PLAN Scale: NTS 6-9 1 /2" 12']0" 12'-0" 12' 4'-6" C 14 3 5/8" 20 GA. METAL STUD TO STRUCTURE ABOVE 1/2"MIN GYP BD TO DECK ABOVE BOX HEADER: 2 X 4 A.C.T. CLG jk (2) 6" 20 GA. METAL @ 8'-0" A.F.F. STUDS W/ 3 5/8" TRACK TOP AND 5/8" GYPSUM BOARD BOTTOM. TO 6" ABOVE FINISHED CEILING W, B.O. BULKHEAD @ T-0" A.F.F. NOTE: IF A GYPSUM BOARD CEILING IS INSTALLED IN THE HALLWAY AN ACCESS PANEL MUST BE INSTALLED FOR ACCESS TO THE WATER HEATER. (MINIMUM 20"x30") SECTION AT SOFFIT Scale: 1" = V-0" TOP OF PEMB PURLIN (TYP) A 3/32" 7x7 AIRCRAFT CABLE. INSTALL HANGER CABLES USING ALL ATTACHMENTS DEVICES AS SPECIFIED BY WIRE MANUFACTURER. TOP OF LIGHT FIXTURE MOUNTED @ 1 V-0" A.F.F., .) MOUNT WITH AIRCRAFT CABLE TO UNISTRUT, UNISTRUT ATTACHED TO UNDERSIDE OF PURLIN. 3 LIGHT ATTACHMENT DETAIL 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 5'-8 1 /2" o KiDIM FROM FACE OF COLUMN ao o 6- T-0" 9'-0" 8'-0" 8 0" le 8'-0" 8'-0" 7'-0" 7'-0" 8'-0" ce) 3 z '-9 1 /2" 12' 0" 12'-0" 6 5 12'-0" 12'-0" 12'-0" REFLECTED CEILING PLAN I I, 16'-0" I I, 14'-0" 12'-0" 3 NORTH Scale: 1/8" = V-0" 12'-0" 2 ins ROSS RUNNERS 10. 12 ga VERTICAL IANGERS IIN. OF THREE URNS IAIN RUNNER SUSPENDED GRID DETAIL 1 Scale: 1" = V-0" --(::D ACT @ 8'-0" A.F.F. GENDER NEUTRAL ,,... 104 ACT Cad 8'-0" A.F.F. ACT @ 8'-0" A.F.F. GENDER NEUTRAL CENTERED IN ROOM OPEN TO ABOVE BREAKROOM CENTER LIGHT IN 100 ROOM OPEN TO ABOVE OFFICE CENTER LIGHT IN---- 1=01 ROOM METAL PANEL CEILING (BY PEMB @ 10'-0" A.F.F. f� LEGEND PANEL/CIRCUIT NO. A/12 LIGHT FIXTURE TYPE A NIGHT LIGHT CIRCUIT A NL LIGHT FIXTURE TYPE B LIGHT FIXTURE TYPE C LIGHT FIXTURE TYPE D SUSPENDED CEILING GRID & ACOUSTICAL CEILING TILE EMERGENCY LIGHT W/ BATTER BACKUP K LIGHT EXIT SIGN W/ BATTERY BACKUP EXIT N WALL PACK J BI-DIRECTIONAL SECURITY LIGHTING M SUPPLY DIFFUSER RETURN DIFFUSER CONSULTANT: SEAL: JOHN BENEDICT POLS1NELLl, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 12/1 8/201 8 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 06/07/201 9 BULLETIN 01 02 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store. #: 20360 Drawing Title REFLECTED CEILING PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.02 3 3 A9 0 BRING RIGID PIPE SLEEVE THROUGH BUILDING TO ALLOW PHONE LINE PENETRATION. SEAL ALL PENETRATIONS. 3/4" PLYWOOD 8'-9" WIDE X 5-5" HIGH, FIRE RATED, NO VOIDS, PAINTED WHITE UNLESS /'`!ll"1C (•11 /'•TA TCC 11TLJCD\A/ICC THROUGH, WALL' SEE ELECTRICAL SPECIFICATION NOTE 'E' AND 'H'. ELECTRICAL PANEL ELEVATION BUZZER PUSH BUTTON BUZZER, A/4 RECEIVING AREA 103 5 PROVIDE NEMA L14-20R RECEPTACLE PROVIDE TOGGLE 20 TOE SWITCH AT WATER HEATER. A/21 Scale: NTS TO RTU-1 4 O GFCI, WP,A/10 RTU-1 DD O O A/1,3,5 VERIFY ACTUAL HVAC ELECT. REQUIREMENTS WITH CONTRACTOR. (TYP). 11 3 DR, LOW TEMP 2#10,1 #1O(G), 3/4"C A/27,29 11 4 DR, LOW TEMP 2#8,1#1O(G), 3/4"C A/31,33 �I LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/ RJ-45 JACK AT MANAGERS OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6' LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END, DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA HUB. -� SALES AREA 102 9 SO CORD (WHITE). ANCHOR TO PURLINS ABOVE. REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS. (TYPICAL) B/36 10 B/36 � DEDICATED QUAD RECEPTACLE ® 3'-0" FOR CCTV EQUIPMENT DEDICATED QUAD RECEPTACLE Q 3'-0" 3 OFFICE ` I A/26 101 A/24 O A/22 VS A/18 A/26 A/26 A/28 _ sw A/20 SECURITY OUTLET AT 7'-0" DEDICATED DUPLEX RECEPTACLE @48" FOR INTERFACE EQUIPMENT. DEDICATED QUAD RECEPTACLE 6'-0" FOR VSAT AND D-LINK EQUIPMENT ENLARGED OFFICE POWER PLAN SCALE 1/4" = V-0" RESTROOM EXHAUST FAN. B/21 CONNECT TO ROOM SENSOR LIGHT CONTROL SWITCH. 0 GFCI A/23 RESTROOM EXHAUST FAN. CONNECT TO ROOM SENSOR LIGHT CONTROL SWITCH. A/32 B/21 TO RTU-2 T A/28 sw 6O � � A/30 4 O A/34 VS sw GFCI, A/28 A/30 A/28WP,A/10 $A/30 -sw DID A/7,9,11 CNJ REFER TO REGISTER POWER POLE SO44 DETAIL 3/E4. B/2,4,6,8,10,12. XI A/34,r,° B/14 7' 8 1/2" 10'-3" 10'-5 1/2" 12'-9 1/2" 12'-8 3/4" OFFICE rA/36 101 _ t I—, AUTOMATIC DOOR A/2 - 2'-3" A/38 4'-5" 4'-4" F A/12 J 1 11 4 DR, LOW TEMP 5 DR, MID TEMP 4 DR, MID TEMP 2#8,1#10(G), 3/4"C 2#12,1#12(G), 3/4"C 2#12,1#12(G), 3/4"C B/22,24 B/26,28 B/30,32 02 POWER PLAN Scale: 1/8" = V-0" LEGEND g BUZZER - TORK MDL #TA725 W/ TRANSFORMER MDL#TA592 PUSH BUTTON 125V NEMA 5-20R DUPLEX. A/23 PANEL/CIRCUIT IN PANEL (sw 125V NEMA 5-20R DUPLEX. A/28 SPLIT WIRED. A/ 0 PAN`EL/CIRCUIT IN PANEL 0 JUNCTION BOX 125V NEMA 5-20R QUAD. VACANCY SENSOR: GREENGATE DUAL TECH LOW VOLTAGE #VAC-DT-0501-R OR EQUAL. PROVIDE WITH SWITCH PACK. T TEMPERATURE SENSOR: BY MECHANICAL LEI DISCONNECT O BLACK MAGIC POWER POLE PHONE JACK @ REGISTER O VOICE/DATA PORT = RJ-11, RJ-45 DATA JACK, PHONE COMBO @ OFFICE A/23 PANEL/CIRCUIT IN PANEL MOTION SENSOR SWITCH. m LEVITON #EZ-FIND-ODS-10-IDW 20 AMP TOGGLE SWITCH NL NIGHT LIGHT CIRCUIT GENDER NEUTRAL 104 j HRUVIUE I UUULE SWITCH AT RESTROOM WATER HEATER. A/19 GENDER NEUTRAL 105 DEDICATED GFCI,WP, 20AMP OUTLET RECESSED @ 4' A.F.F FOR ICE MERCHANDISER, BREAKROOM 02 100 3 E1 NOTE: IF STORE IS LABELED "RELOCATED", PROVIDE J BOX OVER ENTRY DOORS FOR CCTV. C ELECTRICAL SPECIFICATIONS A. ALL WIRING SHALL BE CONTAINED IN CONDUIT OF PROPER SIZE. B. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES. C. SERVICE IS TO BE MINIMUM 400 AMP, 3 PHASE (PREFERRED) 600 AMP 1 PHASE OR LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD. D. REQUIRED CUSTOM BUILT POWER POLE ASSEMBLIES AVAILABLE FROM D&P CUSTOM LIGHTS & PRODUCTS INC. PHONE: (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND INDUSTRIAL ROAD, NASHVILLE, TN 37209. SEE SHEET E3. E. EXTERIOR EXPOSED PHONE LINES TO BE INSTALLED IN RIDGED CONDUIT. PROVIDE EMERSON 3/4" X 5-FT. METALLIC CABLE U-GUARD #755, OR EQUAL. F. ELECTRICAL PANELS TO BE LABELED CORRECTLY AND WITH LEGIBLE PRINT. G. PHONE LINES - TWO RJ-11 PORTS. ONE (1) LOCATED IN OFFICE W/RJ-45 DATA JACK COMBO AND ONE (1) AT REGISTER. 24 GA. CAT 5, 4-PAIR TWISTED WIRE ONLY. USE BLUE AND BLUE & WHITE WIRES. HOOK TO LINE #1 TERMINAL IN RJ-11 JACK EACH PHONE JACK TO HAVE DEDICATED, SEPARATE HOME RUN TO DMARC. LABEL AS "PHONE" AT THE DESTINATION AND AT DMARC. PHONE COMPANY PROVIDES FINAL HOOK UP TO DMARC ONLY. PHONE JACKS ARE SUPPLIED AND WIRED BY CONTRACTOR. H. PROVIDE 1 1/2" EMT CONDUIT TO ACT AS ACCESS SLEEVE TO ALLOW PHONE COMPANY TO TERMINATE AT DMARC. CONTRACTOR TO PROVIDE & INSTALL PHONE WIRING & RJ-11 PHONE JACK FOR A COMPLETED WORKING SYSTEM PRIOR TO PHONE COMPANY FINAL HOOK-UP. L ALL 120 VOLT OUTDOOR RECEPTACLES TO HAVE "WET LOCATION - IN USE" COVERS. J. ALL CONDUCTORS TO BE COPPER, #12 AWG MINIMUM SIZE, OR SIZE AS REQUIRED BY LOAD AND OVER CURRENT PROTECTION. K. SEE EMS SHEETS EMS1 AND EMS2 FOR ENERGY MANAGEMENT SYMBOLS AND INFORMATION. L. ELECTRICIAN TO PROVIDE 1 2" CONDUIT WITH PULL STRING FOR SATELLITE LINE. REFER TO 3/A3 AND 1/S1 FOR LOCATION. M. ALL POWER AND DATA TO BE ROUTED OVERHEAD. UNDER SLAB IS NOT ALLOWED. N. VERIFY WIRE SIZE REQUIREMENTS FOR ALL COOLERS AND FREEZERS. O. MOUNT ALL REFRIGERATOR OUTLETS AT 12" AFF UNLESS NOTED. P. WIRE SIZES SHALL BE BASED ON THE 60 DEGREE CELSIUS AMPACITIES FOR WIRE SIZES #14 THRU #1 AWG AND 75 DEGREES CELSIUS FOR WIRE SIZES #1/0 AND LARGER. Q. BRANCH CIRCUIT WIRE SIZES AND CONDUITS SHALL BE INCREASED FROM THOSE INDICATED ON THE PLANS AS REQUIRED TO PREVENT EXCESS VOLTAGE DROP. BRANCH CIRCUITS $HALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT THE VOLTAGE DROP BETWEEN THE PANEL AND THE LOAD DOES NOT EXCEED 3% TO MEET FLORIDA'S BUILDING CODE, ENERGY CODE PART C405.7. IF ELECTRICAL KEYED NOTES 1� TEST/RESET STATION FOR STAND ALONE DUCT DETECTOR. ONE FOR EACH DEVICE. SEE KEY NOTE 2 ON THIS SHEET. SIMPLEX #4098-9842 IS SPECIFIED WITH PIEZO AND LED INDICATOR. O LOCATION SHOWN FOR MECHANICAL UNITS ARE ONLY APPROXIMATE. CONTRACTOR SHALL CONSULT MECHANICAL AND STRUCTURAL DRAWINGS TO DETERMINE ACTUAL UNIT LOCATIONS. PROVIDE 1/2" PENETRATION THRU ROOF WITHIN FOOTPRINT OF UNIT FOR USE WITH CONTROL WIRING TO UNIT BY OTHERS. PROVIDE PROPER WATERSEAL (TYPICAL). <3> FACTORY MOUNTED POWERED CONVENIENCE OUTLET. FIELD VERIFY THAT OUTLET IS POWERED. PROVIDE WP, GFCI RECEPTACLE AT ALL UNITS AND WIRE TO BREAKER IN PANEL "A" IF THEY ARE NOT FACTORY PROVIDED. ® PHOTOELECTRIC DUCT DETECTOR WITH HOUSING. TIE TO LED READOUT RECESSED IN DUCT STAND ALONE DEVICE, 120V. SIMPLEX #4098-9687 IS SPECIFIED WITH 4098-9842 CONTROL STATION. PROVIDE ONE DEVICE PER UNIT. MOUNT DEVICE IN SUPPLY AIR DUCTWORK. DEVICE SHALL BE PROVIDED AND WIRED TO THE CONTROL STATION BY THE ELECTRICAL CONTRACTOR. HIRE THE MECHANICAL CONTRACTOR FOR INSTALLATION IN DUCTWORK AND CONNNECTION TO SHUT DOWN CONTROLS. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED RELAYS AND 120V POWER. DO NOT POWER DUCT DETECTORS FROM HVAC LOW VOLTAGE. SUBMIT SHOP DRAWINGS FOR APPROVAL. PLACE ANY REQUIRED LABELING ON CEILING TILE DIRECTLY BELOW UNIT. <�> MOUNT DISCONNECT SWITCH AT UNIT. ALL DISCONNECTS SHALL BE HEAVY DUTY.FUSES TO BE TYPE RK-5 TYPE. BUSSMAN FRN-R-(AMP) FUSES ARE SPECIFIED. © MECHANICAL THERMOSTAT AT 8'-0" AFF. VACANCY SENSOR. SENSOR SHALL CONTROL LIGHTS AND TOP HALF OF THE DUPLEX RECEPTACLES INDICATED AS SPLIT WIRED, (A/28). < SPLIT WIRED RECEPTACLES. CIRCUIT A/30 SHALL BE 'ALWAYS ON', CIRCUIT A/28 SHALL BE CONTROLLED BY THE VACANCY SENSOR. RECEPTACLE SECTIONS THAT ARE AUTOMATICALLY CONTROLLED SHALL BE PERMANENTLY MARKED PER ASHRAE STANDARDS. SO WHITE ELECTRICAL CORD IS REQUIRED. SEE SHEET Al, NOTE 25 AND 25A. CONFIRM THE FINAL NUMBER AND LOCATION OF OUTLETS IN THE SALES AREA WITH THE FINAL DOLLAR GENERAL FIXTURE PLAN. PROVIDE JUNCTION BOX MOUNTED AT 90" AFF. COORDINATE WITH COOLER/FREEZER VENDOR FOR MANUFACTURER'S REQUIREMENTS. CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 QP.�FtICK p�0 ,,i �,� �\� 83946 `� zap. No �A STATE OF THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 12/18/2018 PERMIT SUBMITTAL 01 /1 1 /201 9 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 06/07/2019 BULLETIN 01 02 Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title POWER PLAN DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 E1 02 co W MOUNT* SURFACE 1201208 I 3-PHASE, 4W I PANEL A CAPACITY: 400A INT CAP: 22KA 0) W "- 0 LOCATION: BACK OF BLDG. LUGS: MLO DEMAND LOAD* 321A AV. FAULT: 12 KA I- 0 CKT LTG REC HVAC MISC NP DESCRIPTION AMP POLE � AMP POLE DESCRIPTION LTG REC HVAC MISC NP CKT 1 11.0 RTUI 100 3 A 20 1 AUTOMATIC DOOR 0.1 2 C 3 11.0 8 20 1 PHONE BOARD/BUZZER OA 4 C 5 11.0 C 20 1 ENERGY MANAGEMENT 0.2 6 C 7 1 11.01 RTU2 1001 3 A 20 1 SPARE 8 9 B 20 1 OUTDOOR HVAC REC 0.7 10 11 11.0 C, 20. 1 OUTDOOR DRINK VEND 0.2 12 13 SPARE 20 1 A 20 1 SPARE 14 15 SPARE 20 1 B 20 1 SPARE 16 17 SPARE 20 1 C 20 1 INTERFACE EQUIP 0.5 Is C 19 1.7 WATER HEATER #1 20 1 A 20 1 VSATSATA HUB EQUIP 0.5 20 C 21 1.7 WATER HEATER #2 20 1 IBI 20 1 CCTV EQUIP 1.0 22 23 0.2 DRINKING FOUNTAIN 20 1 C 20 1 SECURITY REC 0.2 24 C 25 0.2 OUTDOOR ICE REC -R 20 1 A 20 1 OFFICE REC 0.7 26 C 21 w5 3 L-Wilm' r' '2-r 2 ',-C B 20 1 BREAK ROOM REC 0.5 28 29 2.5 20 1 OFF/BREAKRM RECEPT 0.9 30 C 31 3,2 4 DOOR LOW TMP 40 2 A 20 1 BEAUlrf1COSMEnCS 0.4 32 33 32 B 20 1 ICE CREAM FREEZER 0.8 34 C 35 SPARE 20 1 C 20 1 GATORADE RECEPT 0.6 36 C SFIA 2 -1 A 200 3 PANEL B 38 39 SPARE 20 't B 11.2 1 0.0 0.1 26.2 0-0 40 41 SPARE 20 1 C I PHASE BALANCE LOAD TYPE CONNECTED DEMAND DEMAND FORMULA TOTAL LOAD LIGHTING 11.2 KVA 14-0 KVA LOAD X 1251/6 NEC 210.19 CONTINUOUS CONNECTED DEMAND LOAD % RECEPTACLE 4-9 KVA 4.9 KVA I OKVA + 500% REMAINDER NEC 220 A4 126.1 KVA 11 &7KVA * 28.8 KVA 23% AC 66.1 KVA 52.9 KVA LOAD X 80% (USED MCA IN CALCULATION) 350.OA 321.1A * 70.3 KVA 56% MISC 43.9 KVA 43.9 KVA LOAD X 100% NEC 210.19 NON-CONT. FILENAME: C 1 27.0 KVA . 21% NP 0.0 KVA 0.0 KVA 0 NONCOINCIDENTAL LOADS NEC 220-60 DGZephyrhills FLPaneISc1 NOTES: A. AIC RATING: SERIES RATED AT 200,000 AMPS WITH BUSSMANN JJN FUSES. B. BREAKERS FOR HVAC UNITS SHALL BE SIZED PER MANUFACTURER REQUIREMENTS. ENTS. C. BREAKER LOCK D. ISOLATED GROUND BUS. EQUIPMENT SCHEDULE PLAN MARK EQUIPMENT SERVED LOAD VOLTI PHASE FED BY I DISC BY MCA MOCPD FEEDER REMARKS RTU I ROOFTOP UNIT 33.10KVA 20813 A EC 92.OA 100A (3)#3,#100,1 1/4 "C PROVIDE100A/3P NIF DISCONNECT RTLI 2 I ROOF TOP UNIT f 33.10KVA 20813 I A EC 92.OA, I 100A I (3)#3, #100,1 1/4 "C I PROVIDE 100A13P NF IDISCONNECT I FILENAME: DG Zaphyrhills FL Panel Schedules.xis I 1201208 3-PHASE, 4W PANEL LOAD I CAPACITY: 400A LOAD TYPE CONNECTED DEMAND DEMAND FORMULA LIGHTING 11.2 KVA 14.0 KVA LOAD X 125% NEC 210.19 CONTINUOUS RECEPTACLE 4.9 KVA 4.9 KVA I OKVA + 60% REMAINDER NEC 220.44 HVAC 66.1 KVA 52.9 KVA LOAD X 80% (USED MCA IN CALCULATION) MISC 43.9 KVA 43.9 KVA LOAD X 100% NEC 210.19 NO WCONT. NP 0.0 KVA 0.0 KVA 10 NONCOINCIDENTAL LOADS NEC 220.60 400A DISCONNECT: PROVIDE 600V/3P, 400A/400A BUSSMANN JJN FUSES IN MAIN HEAVY DUTY SERVICE DISCONNECT SWITCH. COORDINATE LOCATION WITH UTILITY COMPANY AND DOLLAR GENERAL. AVAILABLE SHORT CIRCUIT (TYPICAL) 9,753 (2) SETS OF (4)#3/0 CU, 2-1/2"C � CT'S/ METER CABINET PER UTILITY COMPANY REQUIREMENTS (3) SETS OF (4)#500, AL, T-C UNDERGROUND SERVICE ENTRANCE PER UTILITY AND SITE SPECIFIC CONDITIONS. REFER TO SHEET ES1 FOR LOCAL UTILITY CO. POLE/TRANSFORMER LOCATION. G.C. SHALL COORDINATE WITH CIVIL FOR THE EXACT LOCATION OF THE POLE MOUNTED TRANSFORMERS AND MAKE ANY CHANGES TO THE SERVICE ENTRANCE WIRING SIZE IF THE CONNECTION POINT IS DIFFERENT THAN WHAT IS SHOWN. NOTE: REFER TO THE ELECTRICAL SPECIFICATIONS ON SHEET El FOR CONDUCTOR TYPES AND INSULATION. 1/0 SYSTEM GROUND, SEE DETAIL #2/E6 EXTERIOR (4)#3/0 CU, #6G, #61G, 2-1/2"C A 8 N 9,311 . N G G IG IG 9,601 (2) SETS OF (4)#3/0 CU, #3G, #31G, EACH IN 3"C INTERIOR -ELECTRICAL PANEL SCHEMATIC Scale: NTS MOUNT: SURFACE 1 120/208 3-PHASE,-4W PANEL B CAPACITY: 200A INT CAP: 22KA, 0 LOCATION: BACK OF BLDG. LUGS: MLO DEMAND LOAD: 112A AV. FAULT: 12KA 0 CKT LTG REC WAC MISC NP DESCRIPTION AMP POLE Q_ AMP POLE DESCRIPTION LTG REC HVAC MISC NP CKT B,C I OA NIGHT LTS 20 1 A 20 1 PWR TERM BROW N 1.2 2 C B,C 3 02 RECEIVING LTS 20 1 B 20 1 PWR TERM BROWN 1.2 4 C B 5 0.8 704/a SALES LTS 20 1 C 20 1 PWR TERM GREEN 1.2 6 C B 7 0.9 1 1 701% SALES LTS 20 1 1 A 20 1 PWR TERM GREEN 1.2 8 C B 9 1 1.4 70% SALES LTS 20 1 B 20 1 PWR TERM GREEN 1.6 10 C B 11 1-3 70% SALES LTS 20 1 C ;A, 1, 1121- 1jr__ B 13 1.4 30% SALES LTS 20 1 At 20 1 COLD DRINKS COOLER 0.8 14 C B 15 0.6 30% SALES LTS 20 1 Ell� 20 1 1 2 DOOR STAND ALONE 1 0.8 16 C 17 SPARE 20 1 20 2 1 MAX COLD FREEZER 0-9 is C C 19 0.1 EPA ERGENCYIEXIT LTS 20 1 _C1 A0.9 20 C C 21 0.2 0.1 BREAK[OFFICELTS/EFS 20 1 40 2 4 DOOR LOW TEMP 3-2 22 B 23 0.3 BUILDING SIGN 20 1 1 3.2 24 B 25 0.9 PYLON SIGN 20 1 1 15 2 5 DOOR MID TEMP 1.3 26 C 1 B 27 SPARE 20 1 1 k 1 1.3 28 B 1 29 1 02 SITE LIGHTING 20 2 C 15 2 5 DOOR MID TEMP - - - - - - 1.3 30 C 31 0.2 A- 1.3 32 B 33 0.8 EXTERIOR LTS 20 1 B 20 1 SODA COOLERS 1.6 34 C B 35 0.7 FRNTWALUCANPYLTG 20 1 C 20 1 DRINK COOLERS 1.6 36 C B 39 SPACE B SPACE 40 B 41 0.8 EXTERIOR DUSK/DAWN 20 1 C SPACE II PHASE BALANCE LOAD TYPE CONNECTED DEMAND DEMAND FORMULA TOTAL LOAD LIGHTING 11.2 KVA 14.0 KVA LOAD X 1251% NEC 210.19 CONTINUOUS CONNECTED DEMAND -5 LOAD % RECEPTACIL E 0.0 KVA 0.0 KVA I 0KVA + 50% REMAINDER NEC 220.44 37.5 KVA 40_3KVA A 10.6 KVA 2 8% HVAC 0.1 KVA 0.1 KVA LOADX80% (USED MCA IN CALCULATION)( 104AA 11 1.8A B 13.0 KVA 351% MISC 262 KVA 26.2 KVA LOAD X 100% NEC 210.19 NON-CONT. FILENAME: C 13.9 KVA 37% NP 0.0 KVA 0.0 KVA 0 NONCOINCIDENTAL LOADS NEC 220.60 DGZephyrhills FL Panel Scl NOTES: A. AIC RATING: SERIES RATED AT 200,000 AMPS WITH BUSSMANN JJN FUSES. B. ROUTING TO THE EMS PANEL.02 C. BREAKER LOCK. D. ISOLATED GROUND BUS_ This ih-ouid-b-eChiGe-to-iine These are uncoated copper or aluminum voltage for multi -voltage and conductor sizes with CU/AL 60C AmP8cItY Load current in amperes 3 phase systems. For a listed at 30C ambient for reference, 120/240V single phase system select 240V. For other single phase systems select the line- [jiurjWtZr conductor �Uc!�� to -neutral voltage. IV gT-p-hasez �_V NEC tables assume'/ pper�tiug temperature. If conductor Is oversized a lower temperature can be used but this temperature should always be higher than ambient. This value only used for adjusting conductor resistance. LpyC..cqnduii conductors per pi �n rallel See NOTE I below Length of cable In feet done -way distance) ---- - ------ Calculate Vc:�I�D� Reset Estimated voltage drop See NOTE 2 below SERVICE FEEDER VOLTAGE DROP Scale: NTS 02 02 Available Fault Current Calculation t� =mar Ver. 6.6 Utility Symmetrical Fault Current amperes kVA = 150 E = 208 1 = kVA x 1000 = trans. FLA trans. FLA 416 E x 1.732 Isca trans. FLA x 100 x PF PF 1 100%1 transformer Z Z 2.00kloI Isca = ampere short-circuit current RMS symmetrical. lxa 20,819 amperes Point to Point Method Three Phase 208/120 --- Length (distance) FEET w] L Aluminum in Nonmetallic Raceway . ......... ................................ . .... 1.732 x L x I (ASC) 6- .. 20,819 N x C x E L-N # conductors per phase N =1 31 Phase conductor constant C 21,3911 Phase Conductor 500kcmil .... ... .. ..... Volt Line to Line tL-L = Volt f = 1.108 Neutral conductor carts#ant C = 21,391 INeutral Conductor Soo kcrnil Multiplier Volt Lme to Neutral E _N = 120 Volt f M= 1 1+f Line to Line M 0.474 Fault Current from Line to Neutral M 0.342 Transformers to Fault Current at Service Equipment I Main Disconnect witch Isca ,.. fault current at terminals of main disconnect L- L 0 9,878 amperes Isca... fault current at terminals of main disconnect L- N to 7,130 amperes Fault Current from Copper Lm Metal Raceway • Three Phase Three Phase Feeder Length (distance) L 1.732 x L x I (ASC) Isca = 9,878 Phase 7,130 Neutral N xCx EL-N # conductors per phase N =2 EJ Phase conductor constant C 12,84� Phase Conductor 310 1W Volt Line to Line EL-L = 208 Volt f = 0.016 Neutral conductor constant C = 1r844 Neutral Conductor 3j0 ................ Volt Line to Neutral EL-N = 120 Volt Multiplier f = 0.020 M I Line to Line M 0.984 Fault Current at I+f Line to Neutral M 0.980 Panel 'A' Isca x M = fault current at terminal of the panel L- L = 9,722 amperes Isca x M = fault current at terminal of the panel L- N = 6,990 amperes Iranch Circuit Fault from copper in meal Raceway - - ---------- -- . ..... Three Phase Branch Length (distance) L Three Phase =5 1,732 x L x I (ASC) Isca 9,722 Phase 6,990 Neutral N x C x E L-N # conductors per phase N f I Phase conductor constant C =L12,844 / JPhase Conductor 30 Volt Line to Line EL-L = 208 Volt f = 0.032 Neutral conductor constant C = [_12,8441 Neutral Conductor 3/0 Volt Line to Neutral EL-N 120 Volt Multiplier f 0.039 M= I Line to Line M 0.969 Fault Curren at I + f Line to Neutral Mt 0.962 Panel 'B' Isca x M = fault current at terminal of the panel L- L = 9,425 amperes Isca x M = fault current at terminal of the panel L- N = 6,726 amperes FAULT CURRENT CALCULATION Scale: NTS MAIN BONDING JUMPER NEUTRAL BUS BARE COPPER CONDUCTION GROUND BUS (1)#6 TO PHONE BOARD PER NEC 800-40(D) MINIMUM OF 20'-0" OF 1/2" REBAR IN BUILDING WALL FOOTING, (NEC 250-50C) - BARE COPPER GROUNDING ELECTRODE CONDUCTOR (NEC 250-66) \_CADWELD BONDING JUMPER TO PANELBOARD ENCLOSURE SIZE CADWELD PER NEC 250-122 OPTIONAL FOR EXISTING SLAB LIFER. 3/4" X 10' GROUND ROD (NEC VALVE, 250-52) METER SUPPLY OR SIDE UNION BUILDING STRUCTURAL STEEL (NEC 250-52(A)(2) PIPE CLAMP ENTRANCE (PROVIDE SIMILAR (TYP.) CADWELD COLD WATER SERVICE CONNECTION TO FIRE PROTECTION WATER SERVICE ENTRANCE), (NEC 250-50A) JUMPER NOTE: ALL GROUNDING SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. GROUNDING DETAIL Scale: NTS CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 ``RICK P/ E N Z Do No.83946 _0. STATE OF 10p. 11 A A THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNERS AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 12/18/2018 PERMIT SUBMITTAL 01/11/2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 06/07/2019 BULLETIN 01 02 Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title THREE PHASE ELECTRICAL PANELS DO NOT SCALE DRAWING Project No. Drawing No. JCDT. 18.02 3 3 E5