6030 Gall Blvd (4)
0 N O O LOCATION PLAN BEALLS OUTLET #542 ZEPHYRHILLS ) UTL ET SITE PLAN 6030 Gall Blvd, Zephyrhills, FL 33542 INTERIOR RENOVATIONS BID & PERMIT SET 09029017 LOCATION OF BEALLS OUTLET GENERAL NOTES 1. THESE DRAWINGS ARE THE PROPERTYOF THE ARCHITECT AND SHALL NOT BE USED WITHOUTCONSENT. DRAWINGS SHALL NOT BE USED FOR ISSUE OF BUILDING PERMIT UNLESS SIGNED AND SEALED BY THE ARCHITECT. 2. THE ARCHITECT SHALL BE THE INTERPRETER OF THE CONTRACT. THE DOCUMENTS SHOW AN OVERVIEW OF THE WORK REQUIRED UNDER THIS CONTRACT AND RELATED REQUIREMENTS AND CONDITIONS THAT WILL IMPACT THE PROJECT. THE DRAWINGS GENERALLY SHOW THE INTENT OF THE OVERALL COMPLEXITY AND CONCEPTS OF THE PROJECT, AND DO NOT NECESSARILY SHOW ALL DETAILS AND CONDITIONS. 3. THESE PLANS HAVE BEEN PREPARED PER REGULATIONS OF THE FBC 5TH EDITION. THE WORK OF ALL CONTRACTORS SHALL COMPLY WITH THE REQUIREMENTS SET FORTH IN THE AFOREMENTIONED CODE. NO DEVIATIONS FROM THE WORK SHOWN OR REASONABLY IMPLIED SHALL BE UNDERTAKEN WITHOUT THE ARCHITECT'S WRITTEN CONSENT, A COPY OF WHICH WILL BE FILED WITH THE CONSTRUCTION OFFICIAL. 4. THE OWNER AND THE CONTRACTOR SHALL HOLD HARMLESS THE ARCHITECT FROM AND AGAINST ALL LIABILITY CLAIMS, DAMAGES, LOSSES AND EXPENSES INCLUDING LEGAL FEES ARISING OUT OF, OR RESULTING FROM, ERRORS OR OMISSIONS IN THE ARCHITECT'S DRAWINGS AND THE PERFORMANCE OF THE WORK BY THE CONTRACTOR. ALL WORK AND MATERIAL SHALL MEET THE REQUIREMENTS OF ALL LOCAL AND STATE BUILDING CODES AND THE SPECIFICATIONS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS. THE DRAWINGS SHOW THE GENERAL ARRANGEMENTS AND EXTENT OF THE WORK. AS THE WORK PROGRESSES, THE OWNER AND THE CONTRACTOR, AT NO EXTRA COSTS, SHALL MAKE MODIFICATIONS TO MAKE THE PARTS ALIGN. 5. GENERAL CONTRACTOR SHALLCHECK AND VERIFY ALL PLAN DIMENSIONS AND CONDITIONS BEFORE PROCEEDING W/. CONSTRUCTION. HE SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR CORRECTION PRIOR TO BEGINNING ANY WORK. THE DISCOVERY OF DISCREPANCIES AFTER THE BEGINNING OF WORK WILL BE EVIDENCE OF FAULTY WORK AND SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. DO NOT SCALE DRAWINGS. ALL WRITTEN DIMENSIONS GOVERN. CONTRACTOR NOTES 1. THE PROJECT IS AN INTERIOR REMODEL. ONLY MINOR EXTERIOR WORK IS PROPOSED AT THE ENTRY. NO SITE WORK IS PROPOSED. 2. ALL WORK SHALL BE COMPLETED IN STRICT ACCORDANCE WITH ALL MANUFACTURER'S SPECIFICATIONS, GUIDELINES, AND RECOMMENDATIONS AS WELL AS ALL PERTINENT FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES INCLUDING BUT NOT LIMITED TO: FBC 5TH EDITION, FLORIDA FIRE PREVENTION CODE5TH EDITION EXISTING BUILDING ELECTRICAL - N.E.C. 2010, HC ACCESSIBILITY FBC 5TH EDITION CHAPTER 11 FLORIDA MECHANICALCODE 5TH EDITION, FLORIDA PLUMBING CODE 5TH EDITION 3. PRIOR TO START OF WORK, GENERAL CONTRACTOR, (G.C.), SHALL REVIEW THESE CONSTRUCTION DOCUMENTS AND THE PRINTED SCOPE OF WORK TO BE PERFORMED UNDER THE CONSTRUCTION CONTRACT W ITH A DULY AUTHORIZED REPRESENTATIVE OF THE TENANT. THE ARCHITECT DOES NOT REPRESENT THESE DOCUMENTS AS 4. THE CONTRACTOR FOR THIS PROJECT SHALL INCLUDE ALL MATERIALS AND LABOR REQUIRED TO COMPLETE THE TOTAL PROJECT. THE CONTRACTOR SHALL FURNISH AND PAY FOR ALL MATERIALS, TOOLS, EQUIPMENT, LABOR, MACHINERY, TRANSPORTATION, HEAT, WATER, UTILITIES, AND ALL OTHER FACILITIES AND SERVICES REQUIRED FOR THE SAFE AND PROPER EXECUTION AND COMPLETION OF THE WORK. 5. ALL FINAL COLOR AND FINISH SELECTIONS SHALL BE APPROVED, IN WRITING, BY THE TENANT. IN GENERAL, NEW CONSTRUCTION SHALL MATCH EXISTING AND CONTIGUOUS CONSTRUCTION IN COLOR, FINISH, MANUFACTURER, AND INSTALLATION METHOD. 6. G.C. SHALL FIELD VERIFY KEY DIMENSIONS AND CONDITIONS PRIOR TO ORDERING NEW MATERIALS, FINISHES, EQUIPMENT AND FIXTURES. THESE CONSTRUCTION DOCUMENTS ARE BASED, IN LARGE PART, ON TENANT -SUPPLIED RECORD CONSTRUCTION DOCUMENTS ("AS BUILTS"). THE ARCHITECT DOES NOT REPRESENT THAT HE HAS FIELD -VERIFIED THE RECORD CONSTRUCTION DOCUMENTS AND HE DOES NOT CERTIFY THEIR ACCURACY. 7. NOT ALLAREAS OF THE PROJECT LOCATION WERE AVAILABLE FOR OBSERVATION AND VERIFICATION AT THE TIME THESE CONSTRUCTION DOCUMENTS WERE PREPARED. CONSEQUENTLY, THE ARCHITECT DOES NOT CERTIFY THEIR ACCURACY. THESE CONSTRUCTION DOCUMENTS SHALL NOT BE REFERENCED AS A LEASE EXHIBIT. 8• GENERAL CONTRACTOR REMAINS SOLELYLIABLE AND RESPONSIBLE FOR THE FOLLOWING: VERIFICATION OF ALL EXISTING CONDITIONS, UNIT LOCATIONS AND DIMENSIONS COORDINATING W/. TRADES AND TENANT PRIOR TO CONSTRUCTION IDENTIFICATION AND REMOVAL OF ANY AND ALL HAZARDOUS MATERIALS, INCLUDING, BUT NOT LIMITED TO ASBESTOS -LADEN MATERIALS. (NOTIFY TENANT BEFORE REMOVAL, IN WRITING, IF ANY HAZARDOUS MATERIALS ARE DISCOVERED.) THE VERIFICATION AND MAINTENANCE OF ALL EXISTING SETBACKS, EASEMENTS, AND ANY DEED RESTRICTIONS. THE ADEQUACY AND INTEGRITY OF ANY AND ALL STAGING, SCAFFOLDING, SHORING, REINFORCING AND FORM WORK. COORDINATION OF WORKING HOURS, DELIVERIES, TRASH REMOVAL, STORAGE, ETC. WITH LANDLORD. ERECTION PROCEDURE AND SEQUENCE TO ENSURE THE INTEGRITY OF THE BUILDING AND IT'S COMPONENT PARTS DURING CONSTRUCTION. COORDINATION OF ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DETAILS AND DIMENSIONS. ANY DISCREPANCIES BETWEEN SUCH DETAILS AND DIMENSIONS SHALL BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING W/. THE WORK. ACCESS PANELS WHERE REQUIRED AS PER PLANS, SPECIFICATIONS OR INSTRUCTIONS FINALCLEAN-UP INCLUDING THE REMOVALOF ALL DEBRIS LEAVING JOB IN A NEW, BROOM CLEAN CONDITION INCLUDING SERVICE AREAS. 9. CLAIMS FOR CONSEQUENTIAL DAMAGES. THE ARCHITECT AND THE OWNER WAIVE CONSEQUNTIAL DAMAGES FOR CLAIMS, DISPUTES OR OTHER MATTERS IN QUESTION ARISING OUT OF OR RELATING TO THIS PROJECT. THIS MUTUAL WAIVER IS APPLICABLE, WITHOUT LIMITATION, TO ALL CONSEQUENTIAL DAMAGES 8130 Lakewood Main Street Suite 210 Lakewood Ranch, FL 34202 Firm Lic. # AA26001395 & 27389 ARCHITECTS 0 NGINEERS AIA SCOPE OF WORK 1. INTERIOR RENOVATION OF EXISTING BUILDING (REF. LOCATOR KEY & INDEX, THIS SHEET) 2. ERECT NEW METAL FRAMED WALLS AND INSTALL NEW SOLID WOOD DOORS AND FINISHES (INCLUDING REMOVAL OF EXISTING FLOORING - NEW CERAMIC TILE IN RESTROOMS SHALL BE SUPPLIED & INSTALLED BY G.C. ALL NEW VCT FLOORING & VINYL BASE SHALL BE SUPPLIED & INSTALLED BY B.O.S.) AS INDICATED ON PLANS. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF DEMOLITION DEBRIS IN A TIMELY AND ORDERLY FASHION. 4. INSTALL NEW SUSPENDED CEILINGS AS INDICATED ON PLANS- REF. SHEETAE102B. 5. NOT USED. 6. INSTALL NEW DISPLAY WALL PANEL SYSTEM IN SALES AREA AS INDICATED ON PLAN AND ELEVATIONS (REF. SHEET AE201). 7. THE GENERAL CONTRACTOR SHALL MEET W/. THE PLUMBING, MECHANICAL, ELECTRICAL, SPRINKLER, ALARM, ETC. SUB -CONTRACTORS ON -SITE PRIOR TO CONSTRUCTION TO VERIFYANY/ALL EXISTING UTILITY CONDITIONS PERTAINING TO THIS PROJECT/SCOPE OF WORK. MINUTES FROM THIS/THESE MEETING(S) AND FINDINGS IN THE FIELD SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO CONSTRUCTION. 8. IF THESE DRAWINGS AND THE FIELD CONDITIONS ARE NOT IN AGREEMENT, THE CONTRACTOR IS TO NOTIFY THE ARCHITECT BEFORE STARTING ANY WORK. ANY INCONSISTENCIES NEED TO BE CORRECTED BEFORE INSTALLATION BEGINS. IF THE CONTRACTOR STARTS INSTALLATION WITHOUT THE CORRECTED DRAWINGS, THEY WILL BE RESPONSIBLE FOR ANYANDALL COSTS (BEYOND THE ORIGINAL CONTRACTED AMOUNT) INCURRED BY NECESSARY CHANGES TO CORRECT THE INCONSISTENCIES. 9. ROOF IS EXISTING. G.C. TO FIELD VERIFY AND CONFIRM W/. LANDLORD ON WARRANTY ISSUES PRIOR TO CONSTRUCTION. NO NEW ROOF IN THIS SCOPE OF WORK. 10. THE ENTIRE SCOPE OF WORK AND ALL FINISHES SHALL BE VERIFIED BY THE TENANT REPRESENTATIVE PRIOR TO CONSTRUCTION. 11. HVAC & ELECTRICAL & FIRE ALARM SYSTEMS ARE EXISTING TO REMAIN W/ MINOR REVISIONS PER THE ATTACHED DRAWINGS. NOTE: ALL ASPECTS OF EXISTING AND NEW CONSTRUCTION (G.C. TO VERIFY EXISTING CONSTRUCTION IN FIELDCOMPLY W/. FBC 5TH EDITION LANDLORD NOTES 1. ANY AND ALLALTERATIONS TO THE BUILDING ENVELOPE INCLUDING WALL OPENINGS, CONCRETE SLAB WORK, ROOF PENETRATIONS, ETC. SHALL BE APPROVED BY THE LANDLORD AND PERFORMED BYLANDLORD APPROVED CONTRACTOR. 2. NO STRUCTURAL WORK OF ANY KIND (INCLUDING, BUT NOT LIMITED TO: CUTTING, PATCHING, SPLICING, WELDING, OR SUSPENDING MATERIALS OR ITEMS OF CONSTRUCTION FROM EXISTING STRUCTURAL COMPONENTS) SHALL BE UNDERTAKEN BY GENERAL CONTRACTOR OR HIS SUBCONTRACTORS WITHOUT EXPRESS WRITTEN APPROVAL OF LANDLORD. 3. ALL CUTTING, PATCHING AND MAINTENANCE/REPAIR OF EXISTING ROOF SHALL BE APPROVED BY LANDLORD AND EXECUTED BY LANDLORD'S GENERAL CONTRACTOR (PRIOR TO CONSTRUCTION) AND SHALL MATCH BUILDING STANDARD ROOFING D ETA ILS . 4. ANY AND ALLSPRINKLER WORK SHALL BE PERFORMED BY A LICENSED SPRINKLER CONTRACTOR UNDER A SEPARATE SPRINKLER PERMIT. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE CODES. SAID CONTRACTOR TO FURNISH LANDLORD WITH THREE (3) COPIES OF CERTIFIED SPRINKLER CONSTRUCTION DOCUMENTS (INCLUDING SPECIFICATIONS) FOR REVIEW PRIOR TO START OF WORK. CONSTRUCTION NOTES 1. ALL EXISTING STRUCTURAL MEMBERS AND ANY EXTERIOR OPENINGS (ALL EXISTING JOB -SITE CONDITIONS) SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 2. ALL NEW INTERIOR CONCRETE SLABS AND FOUNDATION WALLS AND FOOTINGS SHALL HAVE SOIL POISONING UNDER NEW WORK AND SHALL BE INSTALLED BYA LICENSED CONTRACTOR. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL STATE AND DEPARTM ENT OF AGRICULTURE, STRUCTURAL PEST CONTROL DIVISION REGULATIONS, RULES, DEFINITIONS AND REQUIREMENTS. 3. ALL DIMENSIONAL LUMBER, PLYWOOD, PARTICLE BOARDS, ETC. USED IN CONSTRUCTION SHALL BE FIRE RETARDANT (F.R.T.), U/L CERTIFIED NON- COMBUSTIBLE WHENEVER REQUIRED.ALL NEW INTERIOR CONCRETE SLABS AND FOUNDATION WALLS AND FOOTINGS SHALL HAVE SOIL POISONING UNDER NEW WORK AND SHALL BE INSTALLED BY A LICENSED CONTRACTOR. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL STATE AND DEPARTMENT OF AGRICULTURE, STRUCTURAL PESTCONTROL DIVISION REGULATIONS, RULES, DEFINITIONS AND REQUIREMENTS. 4. NO COMBUSTIBLE MATERIALS ARE PERMITTED ABOVE CEILING, INCLUDING F.R.T. LUMBER. 5. ALL FIRE RATED WALLS MUST HAVE RATING STENCILED IN A READILY VIEWABLE AREA, PER THE FBC 5TH EDITION 6. ALL NEW INTERIOR PARTITIONS SHALL BE CONSTRUCTED OF ONE (1) LAYER 5/8" GYPSUM WALL BOARD (NON -RATED) ON EACH SIDE OF 3 1 /2" (20 GAUGE) PUNCHED-CEE, METAL STUD FRAMING AT 16" ON CENTER (MAXIMUM) UNLESS NOTED OTHERWISE (FINISH AND PREPARE FOR PAINT). ALL NEW PARTITIONS SHALL TERMINATE 6" (MINIMUM) ABOVE HIGHEST CONTIGUOUS CEILING ASSEMBLY UNLESS NOTED OTHERWISE. ALL NEW INTERIOR PARTITIONS SHALL BE NONCOMBUSTIBLE. 7. ALL PLYWOOD BACKING AND ANY IMPERFECTIONS SHALL BE FILLED AND SANDED SMOOTH TO PROVIDE A CONTINUOUS SMOOTH SURFACE FOR APPLICATION OF FINISH (PAINT OR LAMINATE). 8. ALL PARTITIONS WITH DOORS TO HAVE FIRE RETARDANT TREATED WOOD JACK STUDS AND HEADERS. 9. DOOR HARDWARE AT ACCESSIBLE DOORS (INCLUDING EXIT ACCESS DOORS) SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. LEVER -OPERATED MECHANISMS, PUSH -TYPE MECHANISMS, AND U-SHAPED HANDLESS ARE ACCEPTABLE DESIGNS (PER THE AMERICANS WITH DISABILITIES ACT). Phone: 941-556-0757 Fax: 941-556-0759 www.wbrcae.com Douglas W.Whitney INDEX Drawing List G001 COVER SHEET G002 CODE REV I EW PLAN AD101 REMOVALS PLAN AE101 PROPOSED FLOOR PLAN AE102A REMOVALS CEILING PLAN AE102B PROPOSED REFLECTED CEILING PLAN A E103 FIXTURE PLAN AE201 INTERIOR ELEVATIONS AE401 ENLARGED PLANS & DETAILS AE601 DOOR SCHEDULE & TYPES, HARDWARE SCHEDULE AE602 FINISH SCHEDULE & SUPPLIES ITEMS LIST Pi 01 PLUMBING PLAN M101 MECHANICAL PLAN M102 MECHANICAL SCHEDULES AND DETAILS E101 ELECTRICAL PLAN E102 LIGHTING PLAN E103 ELECTRICAL SCHEDULES AND DETAILS FA101 FIRE ALARM NOTES & SPECIFICATIONS FA102 FIRE ALARM PLAN FA103 FIRE ALARM RISER DIAGRAM & CALCULATIONS DEFERRED SUBMITTAL FIRE ALARM DRAW NGS ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS ORDINANCES REVIEW DATE ij l CITY OF ZEPHYR PLAN EXAMINER 3¢ w Z J � CL O� J U J� _J _ 2 V' 4 LU LU co aW_j onto aC0 pU Ode �LL Zak JLj_ Qz BID & PERMIT SET 09029017 Signature Date Owner: Architect: Contractor: Rev. Description Date SHEET No. G001 COMM No. 3542M5 rn J J_ IL H Lu J 0 J J Q Lu m L0 It M �i c Ni N N 0 cz a) m CNI 0 co m DI o� CEILING HEIGHT 1 LAYER $" 'TYPE X' GYP. BOARD �o o 20 GA 3-5/8" GALV. STEEL STUDS @ 16" O.C. (REF. PLAN) NOTE: REFERENCE FINISH SCHEDULE AE602 1 LAYER 6' TYPE X' GYP. BOARD NOTE: PLUMBING WALL IN TOILET ROOMS ARE 6" METAL STUDS. CEILING HEIGHT NEW 5/8" GWB ON BOTH SIDES OF 3 5/8" 20 GA STEEL STUDS @ 16" O.C. NOTE: REFERENCE FINISH SCHEDULEAE602 2x10 WALL PANEL CONTINUOUS 1"x4" HORIZONTAL FURRING STRIPS W3 NEW" GWB ON 1x4 FURRING STRIPS @ EXISTING WALLS. TOP OF PANELS TO CLG CONTINUOUS 1"x4" HORIZONTAL FURRING STRIPS INSTALL NEW 2X 10 WALL PANELS, SEE SHEETAE201 EXISTING EXTERIOR OR DEMISING WALL (SHOWN HATCHED) U CEILING HEIGHT 1 LAYER s"'TYPE X' GYP. BOARD 20 GA 3-5/8" GALV. STEEL STUDS @ 16" O.C. (REF. PLAN) USE MOISTURE RESISTANT GWB IN RESTROOMS AND JANITORS conditions of the site and surrounding area; (ii) the nature, location, and character of the general area in which the Project is located including without limitation, its climatic conditions, available labor supply and equipment costs; and (iii) the quality and IEEE[ a quantity of all materials, supplies, tools, equipment, labor, and professional services necessaryto complete the Work in the manner and within the cost andtime frame required bythe Contract Documents. In connection with the foregoing, and having I carefully examined all Contract documents as aforesaid, and having visited the site, the Contractor acknowledges and declares . that it has no knowledge of any discrepancies, omissions, ambiguities, or conflicts in the Contract documents and that if it I o becomes aware of any such discrepancies, omissions, ambiguities or conflicts, it will promptly notify Owner and Architect of , such fact. Further, Contractor recognizes the extradegree of care required under the urban site construction circumstances I S2 I with respect to safety, protection of pedestrians, cleanliness of the site, health, the other laws, and protection of existing utilities, , adjacent street and property. In arriving at the Contract sum and Contract time, Contractor has, as an experienced and prudent o Contractor, exercised its best judgement and expertise to include the impact of such circumstances upon the Contract sum, and the Contract time. r 21.17 The Contract documents include all items necessary for the proper execution and completion of the Work by the r E40 Contractor. The Work shall consist of all items specifically included in the Contract documents as well as all additional items of work which are reasonably inferable from that which is specified i n order to complete the Work in accordance with the Contract j m documents. The Contract documents are complementary and what is required by any one Contract document shall be as I I binding as if required by all. Any differences between the requirements of the drawings and the specifications or any differences I I noted within the drawings themselves or the specifications themselves have been referred to the Owner and Architect by , Contractor prior to the submission of bids and have been clarified by an addendum issued to al I bidders. If any such differences I I I or conflicts were not called to the Owner's and Architect's attention prior to submission of bids, the Architect shall decide which Mpg if the conflicting requirements will govern based upon the most stringent of the requirements, and, subject to the approval of the Owner, the Contractor shall perform the Work at no additional cost and/or timeto the Owner in accordance with the Architect's decision. 21.18 In connection with the foregoing, Contractor shall be solely responsible for locating (and shall locate prior to performing I any work) all utility lines, telephone company lines and cables, sewer lines, water pipes, gas lines, electrical line, induding, without limitation, all buried pipelines and buried telephone cables and shall perform the Work in such a manner so as to avoid I damaging any such lines, cables, pipes, and pipelines. 21.19 All warranties shall include labor and materials and shall be signed by the manufacturer or subcontractor as the case may be and countersigned by the Contractor. All warranties shall be addressed to the Owner and delivered to the Owner upon l (� completion of the Work and before or with the submission of request for all final payment. i G.C. NOTES: 1. PAINT ENTIRE SIGN FRAME WHITE 2. BUILD AND INSTALL THE POST AND PANEL SIGN. BEALLS WILLSEND THE FOAM GRAPHIC TO ADHERE TO THE PLYWOOD PANEL. BEALLS WILL PROVIDE A SITE PLAN NOTING THE LOCATION OF THE SIGN. 3. INSTALL UPTO (10) 18"x24" LAWN SIGNS AS NOTED ON THE SITE PLAN 4. INSTALL ONE 8' x 20' WALL BANNER AS NOTED ON THE ELEVATION SENT WITH THE SITE PLAN. pr - On N O r 3/4" PLYWOOD 4'x8' 3/4" PLYWOOD o SIGN PANEL 4'x8' 2x4 PRESSURE TREATED WOOD STUD, 8' LONG N r 0 00 2x4 PRESSURE PROVIDE TREATED WOOD SANDBAG AT STUD BRACE PROVIDE EACH U-SHAPE D CORNER STAKES AT EACH CORNER 2x4 PRESSURE TREATED WOOD STUD, 8' LONG LEG L1 TEMPORARY SITE SIGNAGE DETAIL 3/8" = 1 '-0" 192 - 3" 2 COMPUTER 4 E401 340 109 \y .......... _._.... .. _ ....a��aea�.wrw��u\����utivauu�.����wvuu��a����a�\�wvvv0000mo��� � m��omo�o��u�u��������a��ua�uu�u�\oomva0000�or��mr�ti��\\�m\tiaoovo\\�mmw�n\�mv\a00000��0000000���ao�000�omm�ro��moow�o� �u���uvvmroti �� � .. � \. ..,M.M.M.�.�.��,�.M ._....._.........._... -.... � Zz�000��\ ca�aau�u��otioo�o�oo�� ' Q G w I [ JA 6NG I, RECEIVING 'TLT 106 D l= 65 -0 HALL 05 W I 00 8 ' 103 I o r J —2, FE m I; II p J i Q DESK FC CD lltlM 30HS 1ltlM 30HS lltlM 30HS 11tlM 30HS 11VM ]OHS 11VM ]OHS 11VM 30HS 1]VM ]OHS TIVM 30HS _ — _ — _ — _ — _ — _ — _ _ HALL w TLT 07 I? 1s1s z o z a Z 10 1= 0 0 0 0 o g o 0 w w w w w U w O VJ UJ Cn UJ UJ UJ (n 1= O C,g g Z CD O Z g Z 313HS j13HS 313HS ; 313HS FE —rid — I I`_ Z I= w Q r Z LU EXISTING 1 HR ? o w RATEDTENANT i Q J DEMISIN WALL I' 0 z ( Z_e I W Er IlwuJ IE 1= I I I I Ln Ei IIt � o i II r a II I o l , - II N I T I� N I I I I I 1= e I .20 Except when a longer warranty time Is specifically called for In the specification sections of the Contract documents or I manufacturer warranties, or except as otherwise provided by law, Contractor will honor a warranty to Owner for all work ` " I (in duding workmanship and materials and equipment) which shall be for twelve (12) months from the date of substantial FE completion of the entire work or insurance of the certificate of occupancy. 21.21 IF A CONFLICT BE DISCOVERED WITHIN THE CONTRACT DO CI INJFNVTS THE rnKITRAr:Tni SHALL BE CD DEEMED TO HAVE AGREED TO PERFORM THE MOST STRINGENT OR HIGHEST QUALITY WAYOF PERFORMING THE WORK UNLESS IT SHALL HAVE ASKED FOR AND OBTAINED A DECISION, IN WRITING, APPROVED BY OWNER, I FROM THE ARCHITECT BEFORE ENTERING INTO THE CONTRACT. o 21.22 Insurance. Contractor must maintain thefollowing insurance coverages: w A. Worker's Compensation as required by state law, with employer's liability limits of at least $100,000.00 (each accident), $500,000.00 (disease/policy limit) and $100,000.00 (disease/each employee). w B. Comprehensive Automobile Liability, including non -ownership and hired car liability as well as owned automobil ecD coverage with limits of not less than $500,000.00 Bodily Injury and Property Damage on a combined single limit basis. I C. Broad -Form Comprehensive General Liability coverage with at least $1,000,000.00 Bodily Injury and Property Damage in a combined single limit form, which includes the following coverages: CD D. Owner's or Contractor's Protective Liability. I E. Completed operations liability and products liability. F. Blanket Contractual Liability G. Broad -Form Property Damage (including completed operations) Liability.CD H. I. Personal Injury Liability with exclusion"C"deleted. o J. Manufacturer's/Contractor's Operations Liability. w Owner must be named as additional insured on all insurance policies and a Certificate of Insurance in.favor of Owner with a thirty (30) day prior notice of cancellation provision must be on file prior to commencement of work. 21.23 Contractor agrees to pay all sales, use, transaction privilege, income, and othertaxes directly to the appropriate federal, state, or local authorities. No increases oradditions tothe Contract sum will be made as a result of these taxes. 21.24 Compliance with Statutes/Codes. Subcontractor must comply with Federal, State and local laws, and any codes, rules, PEG D PEGGED PEGGED PEG G`-D PEGGED PEGGED regulations and orders of any public authority hearing on the performance of the Work, including, but not limitedto, Social i Security, Unemployment and Workmen's Compensation, Occupational Safety &Health, Equal Employment, Environmental and �""-------"""---""-"-----"� Wage and Price Control Laws. 3 21.25 Gov .rning Law, This Contract will be governed by, construed, and enforced in accordance with the laws of the State of Florida. Any action brought to interpret, enforce, or construe and provision of this Contract must be commenced and maintained in the Twelfth Judicial Circuit Courtin Manatee County, Florida or if the court lacks or declines jurisdiction, in the United States District Court for the middle District of Florida. All parties irrevocably consent to ijurisdiction n v n n r n p y th s and venue and agree of to transfer or remove any action commenced in accordance with this Paragraph. 21.26 Attorneys Fees. If there is any litigation between Seller and Buyer to enforce or interpret any provisions or rights of this Contract, the unsuccessful party, as determined by the court, shall be responsible for all costs, legal fees, and expenses (through trial and appeal), including, but not limited to, reasonable attorneys' fees incurred by the successful party. 21.27 In the event the Work involves an existing location which is being kept open while being remodeled or involves an expansion to an existing store, Contractor shall ensure free and clear pedestrian access to Owner's existing store. Contractor shall use its best efforts to not interrupt the continued operation of the business of Owner sothat Owner can operate as II 'bl C t t 'll k d d t t d 'Ilk d 1' t th f th t � I€ 75'-1 " FE l= �Iw a 1= W Ij Mc [4 C9 - C ti I' CD SHEIIN6, 134'-6" , ' NESTING AB NESTING BlE NESTING B � I ' I I I I i i W III 1 III NESTING ABE BLE NESTING, B E40 l w a I I I IN � LUGGAGE LUGGAGE LUGGAGE LUGGAGE LUGGAGE Il p I ® E' N ET CA E I N ET % P 24X48 24X48 24z48 12WG 4x48 24X48 24X48 r y 0 11 I _ ® IF o / SHOPPINGCARTS 2 2 SHbPPINGCARTS t2 (C i I 181 B 12 0 12 182 480 480 --_-_-__-_-_-_-_-_-_-_-_______._._.__________________J 192 - 3" 4 norma y as posse U. on rac orwl eep noise an us o a minimum an wI eep e Ivery access o e rear o e s ore. n CODE REVIEW PLAN Contractor will use such construction means and methods as are necessary to accomplish the Work as herein described. 21.28 It is agreed that a full time project Superintendent will be the Contractor's Construction Superintendent in charge of the 1 /8" = 1'-0" Project, responsible for the day-to-day supervision of the construction and who will be present during the hours of all construction work, and that there will be no substitutefor such person without Owner's reasonable approval of such substitute who shall have comparable ability and experience. n n A A R 7 A Q 1(1 11 19 1'2 id 1S 1A 17 1A 191 2V 'code review- FBC 5THEDITION building code information 1. USE G ROUP CLASSIFICATION MERCANTILE - CLASS B 2. CONSTRUCTION TYPE MINIMUM TYPE OF CONSTRUCTION REQUIRED TYPE IIIB ACTUALTYPE OF CONSTRUCTION PROVIDED TYPE RIB 3. BUILDING HEIGHT:(TABLE 503) ALLOWABLE BUILDINGHEIGHTSTORY/FEET 2STORY/55FEET ACTUAL BUILDING HEIGHT STORY/FEET 1 STORY /32FEET 4. B UIL DING A REA(TABLE 503) ALLOWABLE BUILDING AREA 37,500 SF W/ SPRINKLER SYSTEM ACTUAL BUILDING AREA - THIS SPACE 22,709 SF -GROSS LEASE SPACE 5.00CUPANT LOAD: EXIT CAPACITY 1640OCCUPANTS ACTUAL OCCUPANCY LOAD 707 TOTAL OCCUPANTS SALES AREA = 20,926 S.F./30 = 698 OCCUPANTS COMP UrE R / LOUNGE = 414 S. FA 00 =5 OCCUPANTS STOCK= 1179 S.F./300= 4OCCUPANTS TOTAL = 707 OCCUPANTS 6. FIRE RESISTANT RATING OF BUILDING ELEMENTS (TABLE 6013TYPE IIIB CONST. A. STRUCTURAL FRAME 0 HR(S) INCL.COLUMNS, GRDERSANDTRUSSES B. BEARING WALLS EXTERIOR >30' WALLS EXTERIOR >30' 0 HR(S) INTERIOR 0 HR(S) C. NONBEARING WALLS & PARTITIONS INTERIOR 0 HR(S) I D. FLOOR CONSTRUCTION 0 HR(S) INCLUDING SUP PORT BEAMS & JOISTS E. ROOF CONSTRUCTION INCLUDING SUPPORT BEAMS &JOISTS 0 HR(S) F. MAX MUM TRAVEL DISTAN CETO EXITS 250 FT. G. MAXIMUM DEAD END 20 FT. H.EGRESSWIDTH PERPERSON.15/INCH (SPRINKLERED) I. MINIMUM CORRIDOFVAISLE WIDTH 3 FEET 7. THRESHOLD BUILDING NO 8. CODES TO WHICH THIS PROJECT WAS DESIGNED FBC 5TH EDITION FLORIDA FIRE PREVENTION CODE 5TH EDITION EXISTING BUILDING ELECTRICAL - N.E.C. 2010 P HCACCESSIBIUTY FBC 5TH EDITION CHAPTER 11 FLORIDA MECHANICAL CODE 5TH EDITION FLORIDA PLUVIBING CODE 5TH EDITION plumbing fixture calcs FBC 5TH EDITION FOR 7070CCUPANTS, (354 MEN & 353 WOMEN) W ATER QI OR FTS FEMALE: 1 PER500 = 1 REQUIRED 1 PROVIDED MALE: 1 PER 500= 1 REQUIRED 1 PROVIDED LAVATORIES p FEMALE: 1 PER 750 = 1 REQUIRED 1 PROVIDED MALE: 1 PER 750 = 1 REQUIRED 1 PROVIDED DRINKING FOUNTAIN: 1 REQUIRED,1 HI-LO PROVIDED SS SERVICE 1 REQUIRED, 1 PROVIDED legend FXIT CAPACITY- 170 ACTUALLOAD IP PULLSTATION 170 — EXIT CAPACITY 35 MAXIMUM ? HORPYSTROBE .-..".......,- TRAVEL' L P L DISTANCE FROM FACP FIRE ALARM FURTHESTPONT CONTROL EXIT SIGN PANEL NEW 2A RATEDMPDC EMERGENCY LIGHT O FE FIRE EXTINGUISHER m W / — — — — EXISTING 1-HR RATED TENANT WALL BRACKET (TYP.) DEMISING WALLS TO REMAIN. a pAd EMERGENCY 2 x 4 UGHT IC NOTE: EX ISTI NG EXIT SIGNS & EMERGENCY LIGHTS SHALL BE REMOVED & REPLACED WITH NEW (TYP.) K NEW FIRE ALARM SYSTEM IS TO BE INSTALLED, FIRE ALARM DRAWINGS WILL BEA DEFERRED SUBMITTAL �4 �C � RIB REV. I DESCRIPTION I DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: PROJECT NORTH I D \ i �L �x 0,� WB R C� ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-55 6-075 9 Lakewood Ranch, FL 34202 www.wbrcae.00m Firm Lic. # AA26001395 & 27389 Dou las W.Whitney AIA BEALLS OUTLET #542 ZE PHYRH I LLS PROJECT: 6030 Gall Blvd Ze h yrhills FL 33542 B CODE REVIEW PLAN SHEET TITLE: WBRCCAD FILE: BEIALLnjOt Eaid HY' H� S54�B.11I OWletZpiyhilIsR-\2D.ign\Dwgs\BIdg,3542tv5 PROJECT No. 3542M5 GRAPHIC SCALE: 0" 1 SCALE: As indicated A PROJECT MANAGER: Approver SHEET No. DRAWN BY: Author G002 CHECKED BY: Checker �wwacnT zom 10 m 1 k Q P 0 N M L K H G F 17) J E J _ W N _ H W J 0 U) J J W D m LO 5 N M m U) 0) 0 U) CV J LL n a> - N a> M 0 a) m B LO 5 N LO M O O M M LO Cr REMOVALS 1 /8" = V-0" O Cl) LL O � A a) r O O d L o 0 1 2 3 4 4 L�/ I 5 tit 6 6 7 7 8 9 10 10 M Is 12 12 13 13 14 15 15 16 17 17 1 18 19 1 20 REMOVAL NOTES: 1. REMOVE ALL EXISTING FLOORING SURFACES IN ENTIRE STORE DOWN TO EXISTING SLAB. SCRAPE GLUE AS REQUIRED TO PREP FLOORS FOR NEW Q FLOORING. ANY GRINDING REQUIRED WILL BE BY GC. PULL & INFILL ANY IN -FLOOR ELECTRICAL BOXES 2. REMOVE EXISTING ENTRY DOORS AND STOREFRONT WINDOWS. PREP OPENING FOR NEW DOORS AND STOREFRONT 3. REMOVE ALL EXISTING WALL PANEL SYSTEM 4. REMOVE ALL EXISTING WALL, DOORS, PLUMBING FIXTURES, TOILET ACCESSORIES AND FLOORING IN RESTROOM. CAP OF ANY UNUSED PLUMBING LINES P AND DRAINS 5. REMOVE EXISTING WALLS, DOORS AND FURNITURE 6. AT EXPANSION AREA REMOVE EXISTING DOORS AND STOREFRONT WINDOWS 7. REMOVE EXISTING DOUBLE DOOR AND MAKE OPENING LARGER FOR NEW DOOR. SEE NOTES ON AE101 PRIOR TO MAKING OPENING LARGER 0 8. AT EXPANSION AREA REMOVE ALL WALLS, DOORS, PLUMBING FIXTURES, COLUMN ENCLOSURES, CEILINGS, LIGHTS AND DIFFUSERS. REMOVE PERIMETER WALLS BACK TO EXISTING CMU WALL. CAP OFF ANY UNUSED PLUMBING LINES AND DRAINS 9. REMOVE EXISTING DEMISING WALL BETWEEN BEALLS AND EXPANSION SPACE. GC TO VERIFY EXACT WALL CONSTRUCTION PRIOR TO REMOVAL. ASSUMED TO BE 5/8" GWB ON BOTH SIDES OF 6" METAL STUDS 10. REMOVE PORTION OF EXISTING WALL FOR NEW N OPENING 11. REMOVE EXISTING DOOR 12. REMOVE / REPLACE PORTION OF EXISTING CONRETE SLAB FOR NEW EAS CONDUIT INSTALLATION 13. REMOVE PORTION OF EXISTING WALL 14. REMOVE / REPLACE PORTION OF EXISTING CONCRETE SLAB FOR NEW SANITATY LINES / DRAINS. M COORDINATE WITH PLUMBING DRAWINGS AND SITE CONDITIONS L K J H G F REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: PROJECT NORTH D WBRCr..:. C ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA BEALLS OUTLET #542 ZEPHYRH ILLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 REMOVALS PLAN SHEET TITLE: WBRC CAD FILE: T103 Projects -Florida\3501-3600\3542M5 Bealls Outlet Zephyrhills FLr2 Design\Dwgs\Bldg\3542M5 BEALLS OUTLET ZEPHYRHILLS.wt PROJECT No. 3542M5 GRAPHIC SCALE: O„ 1r SCALE: 1 /8" = 11-01, A PROJECT MANAGER: Approver SHEET No. DRAWN BY: Author A D 101 CHECKED BY: Checker ©cwvAi rzoo wee 18 19 20 ON ■ co J J_ rr i F W J O J J Q W m LO N CC) C0 U) N C N N J LL r� a N N a) P. IO Z N CM O O CO co LO Q7C) CD J_ N o � r � n 'O oK_ co O O NOTE: CONTRACTOR SHALL SUBMIT STRUCTURAL SHOP DRAWINGS N RA NOT S- 1. INSTALL NEW VCT FLOORING IN SALES AREA, FOR ENGINEERS REVIEW PRIOR TO CONSTRUCTION FOR ALL HALL, VESTIBULE, LOUNGE, COMPUTER. INSTALL STRUCTURAL STEEL. SHOP DRAWINGS SHALL BE REVIEWED BY NEW VINYL COVE BASE ON WALLS NOT COVERED GENERAL CONTRACTOR BEFORE FORWARDING TO ARCHITECT & BY WALL SYSTEM IN SALES AREA, HALL, ENGINEER. FABRICATION CAN COMMENCE AFTER ENGINEER'S CAP PLATE 6"x10"x1 /2" W/ (2) 5/8" VESTIBULE, LOUNGE, COMPUTER AND APPROVED SHOP DRAWINGS ARE RETURNED TO CONTRACTOR ATR EPDXIED 8" INTO BLOCK STOCK/RECEIVING ROOM. (ASSUMED HEADER CONDITION, GC TO VERIFY) 2. PAINT ALL EXISTING COLUMNS ON SALES FLOOR. [a■ an m■ M■ an M. 7■ 7■ 1 1 /8" = 1 '-0" z c7 w Z Z (0 W Z 0_ O 1= 66 X � w W > N Q rn U O NOTE: WRAP ALL STEEL IN BREAK METAL, COLOR TO MATCH DOOR AND WINDOW FINISH �l STOREFRONT FRAMING 1 /4" = 1 '-0" -------------------------------------------------------- HSS 6x4x1 All BASE PLATE 6"x4"x1/2" W/ (1) 5/8" DIA ATR EPDXIED 8". WELD HSS TO BASE PLATE AFTER BASE PLATE IS INSTALLED S - 4" 4' 3 - 0" 12' - 0' EXISTING CPENING GC TO VERIFYOPENING SIZE 3. INSTALL NEW FURRING STRIPS FOR NEW HSS 6x2x1/4" TENANT PROVIDED WALL SYSTEM. TOP TWO ROWS OF FURRING ARE TO BE TAP CON SCREWED AND NOT NAILED INTO BLOCK WALLS. PROVIDE 3/16" WELD ALL AROUND HSS6x2/ HSS 6x4 CONNECTION 4. STRIP IN NEW 1'-4" HIGH GWB BAND ABOVE ALL NEW WALL SYSTEM. PAINT TO CEILING - WHITE. INSTALL CONTROL JOINTS IN THIS GWB BAND EVERY 50'-0" O.C. MAX 5. PAINT ALL WALLS ON SALES FLOOR NOT COVERED BYWALL SYSTEM - WHITE 6. PAINT ALL STOCKROOM WALLS - WHITE 7. INSTALL NEW TOILETS, SINKS, FRP, DISPENSERS, HAND DRYER, GRAB BARS, BABY CHANGER. INSTALL NEW CERAMIC TILE FLOORING AND BASE. 8. INSTALL NEW CERAMIC ON WALL BEHIND DRINKING FOUNTAIN TO 4'-3", PAINT P-3 ABOVE 9 INSTALL SOAP DISPENSER AND PAPER TOWEL DISPENSER IN JANITORS. 10. INSTALL NEW HSS 6x4 COLUMNS, NEW STANLEY DOOR AND STOREFRONT WINDOW. GC TO VERIFY EXISTING OPENING SIZE PRIOR TO ORDERING / INSTALLING 11. INSTALL NEW FIRE ALARM SYSTEM, EQUIPMENT PROVIDED BY BEALLS OUTLET. SEE FIRE ALARM PLANS FOR NEW LOCATION. 12. AREA SHOWN HATCHED IS TO BE ABANDONED IN PLACE AND WILL NOT BE PART OF BEALLS OUTLET 13. INSTALL NEW HONEYWELL PROGRAMMABLE THERMOSTATS, PROVIDED BYBEALLS. SEE MECHANICAL DRAWINGS FOR THESE LOCATIONS 14. INSTALL NEW EAS PEDESTALS AND CONDUIT 15. INSTALL NEW METAL STUD KICKERS/BRACING FROM TOP OF EXISTING RECIVING WALLTO UNDERSIDE OF METAL DECKING. SPACING SHOULD BE NO MORE THAN 32" O.C. 16. INFILL EXISTING OPENING WHERE EXISTING DOORS AND STOREFRONT WERE REMOVED. INSTALL BRICK ON CMU (MATCH EXISTING THICKNESS) PAINT BRICK TO MATCH EXISTING WALL COLOR NEW EXTERIOR DOOR 1010 CONSTRUCTION NOTES 1. PROVIDE A NEW 6'-4"" WIDE X7'-4" HIGH DOOR OPENING LOCATED AS SHOWN ON THE FLOOR PLAN. 2. PROVIDE ONE BLOCK CELLS AT EACH JAMB REINFORCED FULL HEIGHT OF WALL WITH A #5 BAR. 3. NEW WALL REINFORCING TO BE DRILLED & EPDXIED 6" INTO FOOTING OR GROUTED STEM WALL AND CONCRETE TIE -BEAM AT ROOF LEVEL. 4. PROVIDE A NEW CASTCRETE 8F16-1 B/2T LINTEL WITH 8" BEARING AT EACH END. 5. AT DOORSILL REMOVE CONCRETE BLOCK STEM WALL TO 8" BELOW THE FLOOR AND POUR NEW SLAB OVER TOP OF STEM WALL. TIE THE NEW SLAB TO THE EXISTING SLAB WITH #4 BARS DRILLED & EPDXIED 4" INTO THE EDGE OF THE EXISTING SLAB AT 16" ON CENTER. ALSO PROVIDE ONE #4 IN THE NEW SLAB OVER THE TOP OF THE STEM WALL. NOA / FLORIDA PRODUCT APPROVALS: STANLEY DURA STORM 3000 - FL# 18003.1 STOREFRONT - MATCH EXISTING OR KAWNEER IR501 - FL# 8787 DOUBLE EXTERIOR DOOR - SIM OR EQ TO GENSTEEL DOOR "GENSTORM" NOA 15-0825.04 IG ■u I© 1© 1� REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: WBRC 1 ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-55 6-075 9 Lakewood Ranch, FL 34202 www.wbrcae.00m BEALLS OUTLET #542 ZE PHYRH I LLS PROJECT: cnQn n.,u ❑I-4 7--k.nhai- EA '33cn1) B PROPOSED FLOOR PLAN SHEET TITLE B �P�j�nET� HY H00\354M B sell s Ou let Z�Iry rthil Is R\21) es ig'0 gd\BId93542W WBRC CAD FILE: Nt PROJECT No. 3542M5 GRAPHIC SCALE: O11 A SCALE: As indicated PROJECT MANAGER: roverSHEET No. A E 101 DRAWN BY: Author CHECKED BY: Checker Q 2 1 3 1 4 1 5 1 6 8 10 is 0 13 0 1 16 17 18 19 IQ P 0 N M L K H G F U) J E } W N t— - W J 0 U) J J W D m LO N L0 M m m rn 0 c N a> p C N J LL Q m - N N O mg LO 2 N d' LO M O O M O LID M d .0 LL 0o A O J O d N M LO O OF- 3 /-l1 X "/ 1 V U L ABANDONED IN PLACE AND NOT PART OF BEALLS OUTLET REMOVALS 1 /8" = 1'-011 �� --------------- _.._.......__.._.__... .._............_..............-- - ------- ......_... ........... ..__..............."-._ __................... ........`-----...._...._..._._.,.._............ ................_ � 1 1 v 4 5 6 7 8 1 9 10 m 12 13 CEILING REMOVAL NOTES 1. REMOVE ALL EXISTING LIGHTS IN EXISTING BEALLS OUTLET SPACE 2. REMOVE EXISTING CEILING TILES, GRID AND DIFFUSERS. RELOCATE SPRINKLER HEADS TO NEW LOCATIONS AND HEIGHTS, REFER TO SHEET AE102B 3. AT EXPANSION AREA REMOVE ALL EXISTING CEILING TILES, GRID AND DIFFUSERS. RELOCATE SPRINKLER HEADS TO NEW LOCATIONS AND HEIGHTS, REFER TO SHEET AE102B 4. EXISTING CEILING TILES AND CEILING GRID TO REMAIN IN EXISTING BEALLS OUTLET SPACE I O N M L K J H G F REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: PROJECT NORTH \� V WBRC.. G ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 2 10 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA BEALLS OUTLET #542 ZEPHYRHILLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B REMOVALS CEILING PLAN SHEET TITLE: WBRC CAD FILE: 1103 Projects-Florida\3501-3600\3542M5 Bealls Outlet Zephyrhills FL\2 Design0wgs\81dg\3542M5 BEALLS OUTLETZEPHYRHILLS.M PROJECT No. 3542M5 GRAPHIC SCALOil E: SCALE: 1 /8" = 1 1-On A PROJECT MANAGER: Approver SHEET No. DRAWN BY: Author AE 102A CHECKED BY: Checker ©ten r,z waa 14 15 1 16 117 18 19 20 5 U) J J_ _ rr IL w J 0 U) J J Q W (n In 5 LID cY) c J LL M T Q a) N 0 Cz co Ln CO 0 0 0 LO aF_cz Lo Q In � o , q? r � o � C ch 01 —0O I- T a PI NI <1 DI BI Al CAI01 IINU UMILIINU I ILCMINJU GRID TO REMAIN, GC TO VERIFY CEILING HEIGHT (�1 PROPOSED 1 /8" = 1 '-0" 7 Cl in 1R LEGEND FIXTURES A FIRE SPRINKLER HEADS © SPEAKER OSD SMOKE DETECTOR EMERGENCY LIGHT NEW CONTINUOUS ROWS OF 4' LONG 1 LAMP T8 SURFACE MOUNTED SLIMLINE ASYMMETRICAL REFLECTOR STRIP FIXTURES MOUNTED 3' FROM ALLSALES FLOOR PERIMETER WALLS (TYP) NEW 2 x 4 PRISMATIC 3 BULB T-8 FIXTURES EMERGENCY LIGHTS BATTERY CIRCUIT BUILT-IN TO NEW FLUORESCENT LIGHTING 12'-011 CEILING HEIGHT (AS NOTED) H VAC SUPPLY DIFFUSERS RETURN DIFFUSERS FIRE STROBE WALL MOUNTED HORN/STROBE CEILING MOUNTED STROBE CEILING MOUNTED HORN /STROBE WALL MOUNTED *EXIT SIGN CEILING NOTES: 1. ALL LIGHTS SHOWN ON THIS PLAN ARE NEW mr ■G mn on ■V11 2. AT HATCHED AREA INSTALL NEW CEILING TILES, GRID AND DIFFUSERS. ALL SPRINKLER HEADS IN THIS AREA ARE RELOCATED J I I IF REV. I DESCRIPTION I DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: PROJECT NORTH D � 0 WBRCC ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-55 6-075 9 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Dou las W.Whitney AIA BEALLS OUTLET #542 ZE PHYRH I LLS PROJECT: 6030 Gall Blvd Zephyrhills, FL 33542 B PROPOSED REFLECTED CEILING PLAN SHEET TITLE: WBRCCAD FILE: T111Poj.S FlWdd,3501-35ro054MBeellsOtdlet ZopIyrhilIsR\2Dmigi�Dwgs\Bid cj3542W BEALLS WILE T 7EPHYBHILLS.,t PROJECT No. 3542M5 GRAPHIC SCALE: D11 1 �� SCALE: As indicated'"' A PROJECT MANAGER: Approver SHEET No. DRAWN BY: Author A E 102 B CHECKED BY: Checker C) P .1T 7 in Q 1 3 5 I 6 1 7 I 8 1 9 1 10 1 11 1 12 1 13 1 14 I 15 —1 - 16 1 17 I 18 19 20 C] P 0 2 M L K H C F i U) J E J_ _ } w N w J f'— O J J Q D w m Lo N M m N Im 3 0 c rn a) 0 C N J LL Q a� - N O m B LO 5 N Ill' L0 (M O O M O U) M a `o C) L0 66 N A O- U ti �O ^^L LL o 1 2 3 FIXTURE PLAN 1 /8" = 1'-011 4 ' 5 ' 6 ' 7 1 8 ' 9 1 10 1 11 12 13 14 15 16 17 18 NOTES: P 1. UTILIZE AISLE TAPE DEFINE MERCHANDISE AREA. 2. COORDINATE EXACT LOCATION OF AISLE TAPE W/ OWNER REPRESENTATIVE. 3. OWNER SHALL SUPPLY AISLE TAPE. 4. G.C. TO INSTALL AISLE TAPE. 5. VERIFY LOCATION & CONFIGURATION OF FITTING ROOMS W/ OWNER REPRESENTATIVE. O N M L K J H G F REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: PROJECT NORTH WBRC:l ? C ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. 9 AA26001395 & 27389 Douglas W.Whitney ALA BEALLS OUTLET #542 ZEPHYRHILLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 s FIXTURE PLAN SHEET TITLE: WBRC GAD FILE: T:\03 Projects -FloridaM01-36=3542M5 Bealls Outlet Zephyrhills FL\2 Design\Dwgs\B1dg\3542M5 BEALLS OUTLET ZEPHYRHILLS.Nt PROJECT No. 3542M5 GRAPHIC SCALE: 0„ 1 �� SCALE: 1/8 = 11-01,==1 A PROJECT MANAGER: KMM SHEET No. DRAWN BY: KMM AE 103 CHECKED BY: Checker 19 20 i C _____T_T I 1 Q OA 4 7 10 if 12 13 1 16 1 17 1 18 NOTE: TOP TWO ROWS OF FURRING FOR WALL SYSTEM SHALL BE TAP CON SCREWED AND NOT NAILED TO BLOCK WALLS 19 20 C1 P 0 2 1/4" NOTE: INSTALL CONTROL JOINTS AT NEW GWB EVERY 50'-0" O.C. MAX. N 3/16" MAX L K H G F rn J E J_ EL w N F-- w J O U) J J w n m LO N d' M iT m rn 3 0 c rn N a) 0 J LL n a> - N 0 m B LO LO LO Cl) O O M O LO Cl) i CC � G � a .L O LO LL 00 A O U m t` � O O 0- � CO O� H n CONTROL JOINT U 6" = 1'-0" 1 2 3 4 WALL (BLOCK OR METAL STUD) P.T. FURRING WALL PANEL A EDGE STARTER &EDGE TRIM WALL PANEL DETAILS 1 /411 — 1'-011 P-3 B STARTER n SALES AREA INTERIOR ELEVATION L/\IV I IIYV LLLV I I'�IYLLV I V I\LIY IlIIIY 4 SALES AREA INTERIOR ELEVATION 1 /8" = 1'-011 �2' - 0" �2' - 0" 1 N � � 00 O I N VB-1 2'- 7 5/8" 1' SLOPED ADA APRON \\n LOUNGE ELEVATION 1 /411 — 1'-011 5 16 7 8 WALL (BLOCK OR METAL STUD) P.T. FURRING WALL PANEL C MAIN VERTICAL qG L BOTTOM -- � TOM TRACK IS SMALLER THAN TOP TRACK D BOTTOM CHANNEL AT EXPANSION AREA INSTALL NEW 5/8" GWB ON 1x4 FRT FURRING STRIPS ON EXISTING CMU WALL. INSTALL FROM TOP OF WALL PANELS TO CEILING. INSTALL CONTROL JOINTS @50'-0" O.C. MAX SALES AREA INTERIOR ELEVATION 1/8" = 1'-011 n A I\IT PY n 0 O n SALES AREA INTERIOR ELEVATION 9 10 E TOP CHANNEL 28' - 0" (14) 2'-0" PANELS 1'- 9 1 /4" 24'- 5 1 /2" 1'- 9 1 /4" 16'- 0" (8) 2'-0" PANELS I I I I 1'-111/4" 12'-11/2" 1'-111/4" ail 12 13 PAINTED NEW 112" 0 5/8" GWB ON FURRIN (TYP.) CHANNEL 24" PANEL SUSPENDED CLG. CDVERIFY HT. IN FIELD 1 N STANDARD 24" PANEL 4 ROWS CUT STANDARD PANEL OF 1x4 1 AND END TRIM TO MEET FURRING _ AT TOP OF DOOR FRAME 0 1 0 ;ING EL DOOR CUT END TRIM TO BUTT AGAINST SIDES OF DOOR FRAME FINISH FLOOR ELEV. @ 0'-0" STANDARD THIS PANEL WILL BE EITHER A 12", 24" PANEL 16", OR A 24" PANEL, REFER TO NOTES: FIXTURE PLAN -NO WALL PANELS TO BE NARROWER THAN 12" (MINIMUM) NOTE: FIND HIGH SPOT ON THE FLOOR AND INSTALL THE -1 3/4" X 1 3/4" X 1 3/4" ALUMINUM EDGING AND ENTIRE WALL SYSTEM LEVEL WITH THE HIGH SPOT. THIS WILL TRIM (SPEC.'s PER G.C.) CAUSE SOME OF THE WALL SYSTEM TO BE MOUNTED ABOVE THE FINISH FLOOR LEVEL. IF IT GETS TO MORE THAN 2" A.F.F., PAINT THE FURRING STRIP WHITE. WALL PANEL ELEVATION 1 /411 = 1'-011 nAIAIT n O 14 PAINT P-3 15 16 AT CVn AAICIllA1 AnCA 10.1[\TAI 1 Alr\A/ C/OII GWB ON MU =LS TO -01, O.C. 17 18 p N T L K J H G F REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA BEALLS OUTLET #542 ZEPHYRHILLS e PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 INTERIOR ELEVATIONS SHEET TITLE: WBRG GAD FILE: T:\03 Projec s-Florida\3501-36D0\3542M5 Bealls Outlet Zephyrhills FLl2 Design\Dwgs\6ldg\3542M5 BEALLS OUTLET ZEPHYRHILLS-M PROJECT No. 3542M5 GRAPHIC SCAL011 E: SCALE: As indicated A PROJECT MANAGER: Approver SHEET No. DRAWN BY: Author A E 2 01 CHECKED BY: Checker ©-Pr 11 TsWc- 19 20 PI 01 NI LI KI HI G FI U) J E J_ 2 W N W J O U) J J W D m u') LO LO M a� m U) 3 0 c rn pp C ILL n a) - N O m Ma) B LO LO v M 'o 0 0 co 0 0 co a L 0 v L 0L O 1� A U N r-- O o d N co L0 O O 2 c 12'-12" 5 p%" Z-13" -7811 31 011 '-1 a" VERIFY FINAL LOCATION OF FITTING ROOMS W/ B.O.S. PRIOR TO INSTALLATION 42" x 20" DEEP (MIN.) 12'-12'1 24" DEEP (MAX.) BENCH MOUNTED 4'-0 ,, T-88" @17" - 19" A.F.F. IN COMPLIANCE WITH ADA STANDARDS —IN O 1 Iao REG. FITTING CLEAR - ROOM FLOOR H.C. LO SPACE FITTING MIRROR ROOM 24" X 60" T-SHAPED TURNING SPACE MIRROR 24" x 60" 1 %11 Z-611 1'-78" 31_011 41_1811 Ft v NOTE: CLOTHES HOOKS IN FITTING ROOMS SHALL BE MOUNTED AT 40" - 48" A.F.F. 2 BAY FITTING ROOM 1/411 = 1'-011 RESTROOM ACCESSORIES MARK DESCRIPTION MODEL A ELECTRIC HAND DRYER XLERATOR HAND DRYERS-#2KJJ9 B TOILET TISSUE DISPENSER JRT COMBINATION TISSUE DISPENSER - #09551 C SOAP DISPENSER SERIES-1 IN -SIGHT 800 ML 1/PK - #91180 D TOILET SEAT COVER SERIES-1 IN -SIGHT PERSONAL SEAT COVER - #0950 E 24 x 30 FRAMED MIRROR - NO SHELF B-165 - 2430 F PAPER TOWEL DISPENSER LEV-R-MATIC DISPENSER - #09706 H TOILET SEAT PROVIDED & INSTALLED BY G.C. 1 H.C. GRAB BARS B-6806 SERIES, 42" @ SIDE, 36" @ BACK J BABY CHANGING STATION - GRAINGER PART #6PXW4 KOALA CARE -HORIZONTAL K RECESS KIT FOR HAND DRYER RECESS KIT 3DYH4 NOTES-' 1. IF NOT AVAILABLE, USE COMPARABLE FIXTURES FROM OWNER APPROVED VENDOR 2. VERIFY ALL ACCESSORIES W/ OWNER REPRESENTATIVE 3. VERIFY ADA AND LOCAL HC MOUNTING HEIGHTS AND INSTALLATION DIMENSIONS. 4. CONNECT NEW XLERATOR HAND DRYERS TO EXISTING HAND DRYER JUNCTION BOX SCOPE OF WORK A WOMEN'S REST ROOM INSTALL ALL NEW TOILETS, WITH AUTOMATIC FLUSH MECHANISMS, FAUCETS, AND LAVS PER ADA REQUIREMENTS INSTALL TWO (2) ELECTRIC HAND DRYER INSTALL TWO (2) SOAP DISPENSERS SUPPLIED BY B.O.S. INSTALL TWO (2) TOILET TISSUE DISPENSERS INSTALL TWO (2) TOILET SEATS. GC TO PROVIDE & INSTALL INSTALL TWO (2) TOILET SEAT COVERS. B MEN'S REST ROOM INSTALL ALL NEW TOILETS, WITH AUTOMATIC FLUSH MECHANISMS, FAUCETS, AND LAVS PER ADA REQUIREMENTS INSTALL TWO (2) ELECTRIC HAND DRYER INSTALL TWO (2) SOAP DISPENSERS SUPPLIED BY B.O.S. INSTALL ONE (1) TOILET TISSUE DISPENSERS INSTALL ONE (1) TOILET SEAT. GC TO PROVIDE AND INSTALL INSTALL ONE (1) TOILET SEAT COVER GENERAL NOTES: 1. GRAB BARS SHALL BE 33" HIGH AND SHALL WITHSTAND A LOAD OF 300 LB. WITHOUT PERMANENT DEFLECTION. SHALL BE PARALLEL TO THE FLOOR SHALL ADHERE TO STANDARD DIMENSIONS. PROVIDE 1-1/2" O.D. DIA. WITH A MINIMUM CLEARANCE OF 1-1/2" FROM THE WALL. 2. CERAMIC TILE FLOORS SHALL HAVE A 7.5% ABRASIVE CONTENT. 3. WHENEVER MORE THAN (1) WATER FOUNTAIN IS PROVIDED, AT LEAST (1) SHALL MEET BARRIER FREE REGULATIONS. 4. AT LEAST (1) MIRROR SHALL BE MOUNTED NO HIGHER THAN 40" FROM THE FLOOR OR THE MIRROR SHALL BE TILTED FOR VISIBILITY. 5. ALL DISPENSING MACHINES SHALL BE NO MORE THAN 40" FROM THE FLOOR. 6. PROVIDE A 5'X5' TURNING DIAMETER WITHIN THE TOILET ROOM. 7. INCLUDE A FLUSHING MECHANISM OTHER THAN FLOOR OPERATED. 8. EACH BARRIER FREE TOILET ROOM SHALL HAVE AT LEAST (1) LAVATORY WITH A NARROW APRON MOUNTED MIN 27 FROM FINISHED FLOOR TO BOTTOM OF THE APRON. CONTROLS SHALL BE A MAXIMUM 20" FROM THE FRONT EDGE OF THE VANITY. LAVATORY RIM SHALL BE MAX 34" HIGH. FAUCETS SHALL HAVE LEVER TYPE HANDLES, NO SELF CLOSING FAUCETS. LAVATORY DRAIN PIPES SHALL BE INSULATED TO PREVENT BURNING. 9. URINALS SHALL HAVE AN ELONGATED LIP AND THE OPENING OF THE BASIN SHALL BE 17" FROM THE FINISHED FLOOR OR BE FLOOR MOUNTED. 1 2 3 0 bo PROVIDE VINYL I 6 7 24'-512" 8 10 1 11 1 12 1 FYIQTIAI(, 01,A' CI IQDGr%im= l (`F11 IN(, �p8° 2'-6" 1 71$ 2'-6" �'-72'2'-6" �1_7 ' 2'-6" �V-72" 3'-0" 4'-1 a" NOTE: DIMENSIONS (OTHER THAN ADA) ARE APPROXIMATE - REFERENCE MANUFACTURER FOR SPECIFIC DIMENSIONS NOTES: 1. POWER POLES & CASH WRAP SUPPLIED BY TENANT & VERIFY FINAL LOCATION OF INSTALLED BY GENERAL CONTRACTOR FITTING ROOMS W/ B.O.S. 2. DEDICATED QUAD OUTLET BELOW COUNTERTOP @ PRIOR TO INSTALLATION 42" x 20" DEEP NETWORK COUNTER CASH WRAP (MIN.) / 24" DEEP (MAX.) 24'-5y2" BENCH MOUNTED � 4'-O8" 4'-O$" 4'-08" 4'-O$" T-8$" COMPLIANCE w I CASH WRAP ELEVATION ADA STANDARD 1/4"= 1'-O" B NC ES _N O 1 lao REG. REG. REG. REG. 30" x 48" CLEAR FITTING FITTING FITTING FITTING FLOOR ROOM ROOM ROOM ROOM SPACE H.C. FITTING MIRROR MIRROR MIRROR MIRROR ROOM 24" x 60" 24" x 60" 24" x 60" 24" x 60" T-SHAPED TURNING SPACE TYPICAL EXISTING ED 1.NOTES: SUSPENDED ER POLES & CASH WRAP '-7$" 4'-12" MIRROR 24" x 60" SUPPLIED BY TENANT & CEILING. INSTALLED BY GENERAL CONTRACTOR 2'-6" 21-61 11_7811 2,-6„ 11_7811 21_611 -7811 T-0" VERIFY HEIGHT IN FIELD 2. NEW ELECTRICAL QUAD OUTLETS - ONE CIRCUIT FOR TWO CASH WRAPS NOTE: CLOTHES HOOKS IN FITTING ROOMS F7 r_1 17 SHALL BE MOUNTED AT 40" - 48" e e e e A.F.F. 5 BAY FITTING ROOM $ PHONE/DATA JACK (TYP.) DEDICATED QUAD OUTLET (TYP.) NOTE: DIMENSIONS (OTHER THAN ADA) ARE APPROXIMATE - REFERENCE MANUFACTURER FOR SPECIFIC DIMENSIONS CASH WRAP ELEVATION 7 1 /411 = 1'-011 P-2 CER-2 A K CER-1 0 M I �. lIVLV IIYVVL COVERS @ ALL EXPOSED PIPING BELOW LAVS (TYP) n TLT 103 (TLT 104 SIM) n TLT 103 (TLT 104 SIM) I 1 /4" = 1'-0" U 1 /4" = 1'-0" TOILET FLOOR TILE PLANS 1 /411 = 1'-011 5" 5' - 0" 5" 5' - 0" 5" 2'- 7" 7 1/4" 30x48 CLEAR FLOOR AREA PAINT DOOR AND FRAME ON INSIDE OF TLT ROOM P-2 GC TO PROVIDE AND INSTALL BOBRICK B-233 CLOTHES HOOK 48" A.F.F. ON ° EACH RESTROOM DOOR � o � 1 N WALL TILE GROUT LINES ARE TO LINE UP WITH FLOOR TILE 16TLT 103 (TLT 104 SIM) GROUT LINES U 1/4" = 1'-0" I I II li I I I L -----J INSTALL CERAMIC TILE 7 1/4" g' - 0"TO 4'4", PAINT P-3 ABOVE 11177117 -- - r Q30x48 CLEAR A —12 K - ` FLOOR AREA — — --- —r ------ 5' DIA i ---E -- TURNING C 0 11 AE4!01 116 RADIUS 1i\ --17 5'x5' CLEAR FLOOR AREA J❑ D B H ...... L 7 1/4" 8' - 0" 5" 5' - 0" 5" 8'- 0" 7 1/4" 4 1 5 1 6 NG TAB ING SEE OPPOSITE SIDE I� FOR EAS SYSTEM TLT 103 (TLT 104 SIM) U 1/4" = 1'-011 r-A 11 Arf!'%r-r% nA f'1 I\A/rfAM 4'- 0" ALCOVE WALLS v - n v2" 14 1 15 1 16 1 CAT 5 CABLE TO RACK IN MGR'S OFFICE CAT 5 BOX PLUG IN DUPLEX OUTLET ° DATA OUTLET - SINGLE HOLE DATA PLATE 17 SEE PLAN ON— AE401 FOR \ \ DIMENSION \ \ \ \ PEDESTAL BY SEN TECH PROVIDE 3/4" CONDUIT UNDER \ \ SLAB FROM DATA OUTLET TO \ TURN CONDUIT UP CENTERLINE OF FIRST \ \ 90 PEDESTAL. CONDUIT & \ \ DEGREES AND CUT TRENCH \M FLUSH WITH THE FROM WALL SHALL NOT BE _ _ _ — — — — — TOP UNDER THE PEDESTAL — — — — — — — OF THE SLAB. 1" CONDUIT CENTERED UNDE PEDESTAL 1" "T" CONNECTOR PROVIDE 3/4" CONDUIT UNDER SLAB FROM CENTERLINE OF FIRST PEDESTAL TO CETERLINE OF 3/4" 3/4" SECOND PEDESTAL EAS SYSTEM ISOMETRIC 17" - 19" _ = 811 W 0 O Z U W E] MIN 0� W C1 O U ao LL - 0 8 7/8" 6 3/8" `1 - ¢ N 611 MIN r 0 CV i MAX N � 1'- 3 1/8" MIN FRONT VIEW SIDE VIEW DRINKING FOUNTAIN ELEVATION = 1'-011 3/4" 12'- 5 1/4" 5' - 0" 1'- 2 3/4" SHEL\/INC SHELVING NULL T z 1 w T 01�v COKE SHEH/IrNG Vdal 9'-01, NEW DUPLEX OUTLET AT b 7 NEW POWER POLE FOR COKE MACHINE Z 000 ,19 000 u oO� 7 INSTALL NEW 3 PIN OUTLET AND DATA OUTLET FOR NEXUS AE401 AE401 BOX. INSTALL 4x4 BOX @ 48" A. F. F. TO 5 27' - 2 1/2" CENTERLINE OF BOX CABINET CAB IN ET RECESSED MOUNTING KIT FOR HAND DRYERS N.T.S. 00 INSTALL NEW PROVIDE 3/4" CONDUIT SECURITY KEYPAD, UNDER SLAB FROM WALL DIGITAL LIGHT SWITCH TO FIRST PEDESTAL AND AND FIRE ALARM FROM FIRST PEDESTAL ANNUNCIATOR TO SECOND PEDESTAL 7 g 9 1 10 1 11 1 12 13 14 15 16 - - 18 19 12' 12' 1 2' 2' 12' 12' 20 CART STOP PIECES (4) CSR-12A-501 RED (12' LENGTH) (2) CSR-2A-501 RED (2' LENGTH) n CART STOP DETAILS J 1/211 — 1'-011 Q P 0 N M L K J H G F REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: C ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 one 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbreae.com Firm Lic. # AA26001395 & 27389 Douglas W.Whitney ALA BEALLS OUTLET #542 NEW DUPLEX OUTLET. LEPHYRH I LLS PROVIDE 3/4" CONDUIT IN PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B WBRC WALL, EXTEND TO ABOVE CEILING ENLARGED PLANS & NEW DATA OUTLET W/ SINGLE DATA PLATE. PROVIDE 3/4" CONDUIT IN WALL DETAILS WITH PULL STRING. RUN CONDUIT ABOVE SHEET TITLE: CEILING AND PROVIDE A CAT 5 BOX PLUG. RUN CAT 5 FROM BOX PLUG TO WBRC CAD FILE: B�«SoUnFTZFPHYRH��SM Z"SBea"s°""e1ZeP"YfiIIIsFL2°es'9 ° 95`e'°9`3�Z""5 RACK IN MANAGERS OFFICE. DATA PROJECT N°. 3542M5 GRAPHIC SCALE: 1 CABLE RUN BY BEALLS 0" SCALE: As indicated A PROJECT MANAGER: Approver SHEET No. DRAWN BY: Author AE401 CHECKED BY: Checker (D 00-1ch*2007 17 18 19 20 111 'I T1 71L to J J_ m w N I— w J O m J J Q w m LO to M rn m as 3 0 c >a a� 0 N >, a a� N O m a> m to N Nt LO M 'o 0 m c? r- O O d o o 3 CENTER LINE OF KNOB LOCKSET / LATCHSET CYLINDRICAL DOOR HARDWARE LOCATIONS II%�IQ�7� RAINIHOOOD DETAIL111 WALL FASTENER AT 12" O.C. 16 GA GALV. STEEL DOOR HOOD MIto OLD STEEL UP NDERNEATH TO CREATE RIP EDGE @ OUTER EDGE ASTENER AT END PUSH PLATE 3' - 0" CENTER LINE OF PUSH PLATE 3070 S.C. BIRCH WOOD DOOR (PAINTED) DOOR TYPES 1 /2" = 1'-011 0 PULL BAR (WITH PLATE) 7 CENTER LINE OF PULL BAR 3'- 0" 3' - 0" B\ 3070 ALUM FACED IMPACT DOOR W/ DOUBLE ACTION HINGES AND PLEXIGLASS VISION PANEL 1u z O �m J Q C0 z 2" 3'- 0" 2" 1 METAL FRAME (PAINTED) n FRAME TYPES a/ 1 /211 — 1'-011 PRIMARY OTHER 9 FLOOR L NOTES: -SIGNAGE PROVIDED BY B.O.S. -ALL SIGNAGE SHALL CONFORM WITH STATE ACCESSIBILITY CODE AND AMERICANS WITH DISABILITIES ACT n SIGNAGE ELEVATIONS 1'-011 IS ( 14 IJ IJ 2 ti r 1' " 4 4 c+T� 1-102 0 CD -OMEN 41Z,r 412" O RESTROOM SIGNAGE REQUIREMENTS SIGNAGE SHALL COMPLY WITH ADA HANDICAP REQUIREMENTS: ROOM Qr PACE DESCRi19ION SIGNAGE DETAILS 1 1 /2" = 1'-0" Ila l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a 1n SATIN CHROME STAINLESS STEEL ANODIZED ALUMINUM MILL FINISHED ALUMINUM CLEAR ANODIZED ALUMINUM 19 COMPUTER COMPLETE SET # 1 JANITOR/STORAGE ROOM - COMPLETE SET # 6 1 HM FRAME 16 GA. KD 3070 X 5 7/8 X ASA X CR 1 HM FRAME 16 GA. KD 3070 X 5 7/8 X ASA X CR 1 SC BIRCH DOOR 3070 X 1 '/ X FLUSH X CYL LOCK PREP 1 SC BIRCH DOOR 3070 X 1 3/ X FLUSH X CYL LOCK PREP 3 HINGES BB1279 — 4.5" X 4.5" X US26D 3 HINGES BB1279 — 4.5" X 4.5" X US26D 1 CLOSER 5200-MLT-1-6 -BF-ALM 1 CLOSER 5200-MLT-1-6 -BF-ALM 1 DOOR SCOPE VIEWER DS-1000 X GREY MG 1 I/C CORE LOCKSET B581 BDC DANE X 626 1 I/C CORE LOCKSET B581 BDC DANE X 626 1 KICKPLATE 190S 8" X 34" X US32D 1 KICKPLATE 190S 8" X 34" X US32D 1 KICKDOWN DOOR STOP 270D X 4" X US26D 1 KICKDOWN DOOR STOP 270D X 4" X US26D 1 WALL STOP 236W X US32D 1 WALL STOP 236W X US32D 3 SILENCERS 307D X GREY 3 SILENCERS 307D X GREY SINGLE EXIT DOOR — COMPLETE SET # 7 RESTROOM PUSH/PULL COMPLETE SET # 2 1 HM FRAME 16 GA. W & S 3070 X 5 3/4 X RIM PANIC X RK 1 HM DOOR 18 GA. 3070 X 1 % FLUSH X RIM PANIC X RK 3 HINGES BB1279 4.5 X 4.5 X NRP X 26D 1 HM FRAME 16 GA. KD 3070 X 5 7/8 X BLANK JAMB X CR 1 CLOSER 5200-PAR-MLT-1-6 - BF-HDS-ALM 1 SC BIRCH DOOR 3070 X 1 3/ X FLUSH X NO LOCK PREP 1 DOOR SCOPE VIEWER DS-1000 X GREY MG 3 HINGES BB1279 — 4.5" X 4.5" X 26D 1 EXIT ALARM 2670 X 3216 X US28 GUARD-X EXIT ALARM 1 CLOSER 5200-MLT-1-6 -BF-ALM 1 KICKPLATE 190S 8" X 34" X US32D 1 PUSH PLATE 30S — 4"X16" - US32D 1 KICKDOWN DOOR STOP 270D X 4" X US26D 1 PULL PLATE 33E — 4"X16" - US32D 1 PULL 8N X US32D 1 KICKPLATE 190S 8" X 34" X US32D 1 THRESHOLD 413S X 36" X MIL 1 KICKDOWN DOOR STOP 270D X 4" X US26D 1 WEATHERSTRIPPING 891S 36" X 84" MIL X VINYL 1 WALL STOP 236W X US32D 1 SWEEP 754S 36" X CLR NEOPRENE 3 SILENCERS 307D X GREY DOUBLE EXIT DOORS — COMPLETE SET # 8 RESTROOM PRIVACY COMPLETE SET # 3 1 HM FRAME 16 GA. W & S 6070 X 5 3/4 X RK 1 HM DOOR (ACTIVE) 18 GA. 3070 X 1 % FLUSH X RIM PANIC X RK 1 HM FRAME 16 GA. KD 3070 X 5 7/8 X ASA X CR 1 HM DOOR (INACTIVE) 18 GA. 3070 X 1 % FLUSH X SURFACE BOLT X 1 SC BIRCH DOOR 3070 X 1 3/ X FLUSH X CYL LOCK PREP RK 3 HINGES BB1279 — 4.5" X 4.5" X US26D 6 HINGES BB1279 4.5 X 4.5 X NRP X 26D 1 CLOSER 5200-MLT-1-6 -BF-ALM 2 CLOSERS 5200-PAR-MLT-1-6 - BF-HDS-ALM 1 PRIVACY LEVERSET B301 DANE X 626 1 DOOR SCOPE VIEWER DS-1000 X GREY MG 1 KICKPLATE 190S 8" X 34" X US32D 1 EXIT ALARM 2670 X 3216 X US28 GUARD-X EXIT ALARM 1 KICKDOWN DOOR STOP 270D X 4" X US26D 1 DOUBLE DOOR STRIKE 2609 X BLK 1 WALL STOP 236W X US32D 2 SURFACE BOLTS 1582 X 26D (LOCKING) 3 SILENCERS 307D X GREY 2 KICKPLATES 190S 8" X 34" X US32D 2 KICKDOWN DOOR STOP 270D X 4" X US26D 2 PULLS 8N X US32D LOUNGE PASSAGE COMPLETE SET # 4 1 THRESHOLD 413S X 72" X MIL 1 WEATHERSTRIPPING 891S 72" X 84" MIL X VINYL 2 SWEEPS 754S 36" X CLR NEOPRENE 1 HM FRAME 16 GA. KD 3070 X 5 7/8 X ASA X CR 1 SC BIRCH DOOR 3070 X 1 '/ X FLUSH X CYL LOCK PREP 3 HINGES BB1279 — 4.5" X 4.5" X US26D 1 CLOSER 5200-MLT-1-6 -BF-ALM DOUBLE EXIT DOORS — LIFE SAFETY — COMPLETE SET # 9 1 PASSAGE LEVERSET B101 DANE X 626 1 KICKPLATE 190S 8" X 34" X US32D 1 KICKDOWN DOOR STOP 270D X 4" X US26D 1 HM FRAME 16 GA. W & S 6070 X 5 3/4 X MULLION REIN. X 1 WALL STOP 236W X US32D RK 3 SILENCERS 307D X GREY 1 HM DOORS PAIR 18 GA. 3070 X 1 % FLUSH X RIM PANIC X RK 6 HINGES BB1279 4.5 X 4.5 X NRP X 26D 2 CLOSERS 5200-PAR-MLT-1-6 - BF-HDS-ALM 2 EXIT ALARMS 2670 X 3216 X US28 GUARD-X EXIT ALARM LOUNGE COMBINATION LOCK COMPLETE SET # 5 1 REM. MULLION 4954 X T REMOVABLE MULLION X US28 2 KICKPLATES 190S 8" X 34" X US32D 2 KICKDOWN DOOR STOP 270D X 4" X US26D 1 HM FRAME 16 GA. KD 3070 X 5 7/8 X ASA X CR 2 PULLS 8N X US32D 1 SC BIRCH DOOR 3070 X 1 3/ X FLUSH X CYL LOCK PREP 1 THRESHOLD 413S X 72" X MIL 3 HINGES BB1279 — 4.5" X 4.5" X US26D 2 WEATHERSTRIPPING 891S 36" X 84" MIL X VINYL 1 CLOSER 5200-MLT-1-6 -BF-ALM 2 SWEEPS 754S 36" X CLR NEOPRENE 1 COMBINATION LOCK 5021 B-WL-26D-41 1 KICKPLATE 190S 8" X 34" X US32D ELIASON DOORS — COMPLETE SET # 10 1 KICKDOWN DOOR STOP 270D X 4" X US26D 1 WALL STOP 236W X US32D 3 SILENCERS 307D X GREY 1 HM FRAME 16 GA KD 6070 X 5 7/8 CASED OPENING FRAME W/ ELIASON DOOR PIVOT PREP X CR 1 ELIASON DOOR (PAIR) 6070 X LWP-3 13 14 15 16 17 18 IF REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA BEALLS OUTLET #542 ZEPHYRHILLS E PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 DOOR SCHEDULE & TYPES, HARDWARE SCHEDULE SHEET TITLE: WBRC CAD FILE T:\03 Projects- Florida\3501-36=3542M5 Bealls Outlet Zephyrhills FL\2 Design0wgslBldg\3542M5 BEALLS OUTLET ZEPHYRHILLS-A PROJECT No. 3542M5 GRAPHIC SCALE: O„ 1 �� SCALE: As indicated F PROJECT MANAGER: Approver SHEET No. DRAWN BY: Author A E 6 0 1 CHECKED BY: Checker QooPva rrz we 14 9n 1 2 3 4 7 10 12 13 14 15 16 i 17 1 18 19 20 OWNER/TENANT SUPPLIES ITEMS LIST ITEM VENDOR ITEM # DESCRIPTION PROVIDED INSTALLED AISLE TAPE GRAINGER 6JT41 2" x 36 YARDS BLACK 00021200434297 OWNER OWNER POWER POLES (A) GRAINGER IMXR7 IMXT1 IMXT4 HUBBELL POWER POLE 10'-0" BLANK HUBBELL POWER POLE 12'-0" BLANK HUBBELL POWER POLE 15'-0" BLANK OWNER G.C. POWER POLES (B) GRAINGER IMXR4 IMXR5 IMXR6 HUBBELL POWER POLE 10'-0" W/ RECEPTACLE HUBBELL POWER POLE 12'-0" W/ RECEPTACLE HUBBELL POWER POLE 15'-0" W/ RECEPTACLE OWNER G.C. WIREMOLD GRAINGER G20GB306 W30 G201OA3 ELEC. FOR LP & MGR. OFFICE 4'-0" OUTLET STRIP (HARDWIRED) WIRE MOLD PRESSURE CONNECTOR WIRE MOLD ENTRANCE END OWNER G.C. LIGHT FIXTURES (SEE LIGHT FIXTURE NOTE BELOW E SAM JONES SEE FIXTURE SCHEDULE BELOW SEE FIXTURE SCHEDULE BELOW OWNER G.C. XLERATOR GRAINGER 2KJJ9 302161 HAND DRYER OWNER G.C. RECESS KIT GRAINGER 3DYH4 RECESSED MOUNTING KIT OWNER MOP SINK GRAINGER IRLN7 6YJ52 MOP SINK MOP SINK FAUCET WITH HOSE CONNECTION OWNER G.C. DOORS & HARDWARE AMERICAN DOOR & HARDWARE SEE LIST ON AE601 OWNER G.C. LAMPS GRAINGER 2ETU3 F32T8/XL/SPX41/ECO. CASE OF 36 OWNER G.C. CART CORRAL GRAINGER CSR-2A-501 RED CSR-12A-501 RED CART STOP RE 2' LENGTH CART STOP RE 12' LENGTH OWNER G.C. THERMOSTAT GRAINGER HONEYWELL #1YMG4 HONEYWELL 7350B OWNER G.C. BABY CHANGER GRAINGER 6PXW4 MODEL # KB200-00 KOALA CARE HORIZONTAL OWNER G.C. H/C SIGNAGE SUN GRAPHIC TECHNOLOGY OWNER G.C. V.C.T. & 4" VINYL BASE CHECK W/ BOS P.M PROJECT DEVELOPED BY OWNER BY OWNER VINYL COMPOSITION TILE FLOORING & 4" VINYL COVE BASE OWNER OWNER WALL PANEL SYSTEM WALL PANEL SYSTEM OWNER G.C. CASH WRAP CASH WRAP OWNER G.C. FITTING ROOMS FITTING ROOMS OWNER G.C. BLUE BOX GRAINGER LIGHTING CONTROL SYSTEM OWNER G.C. R.T.U'S LENNOX ENERGENCE SERIES ROOF TOP UNITS W/ R410A REFRIGERANT OWNER G.C. ENTRY SLIDER & VESTIBULE DOORS STANLEY ACCESS TECHOLOGIES, INC STANLEY DURA STORM (IMPACT RATED) OR DURA GLIDE (NON -IMPACT RATED) FOUR PANEL BIPART DOOR STANLEY DURA STORM (IMPACT RATEDO OR DURA GLIDE (NON -IMPACT RATED) TWO PANEL SINGLE SLIDE DOOR PACKAGE: 100" x 92" (ROUGH OPENING) CLEAR ANODIZED FINISH PROVIDED & INSTALLED THROUGH STANLEY ACCESS TECHNOLOGIES, INC BY OWNER LOUNGE COUNTERTOP / CABINETS INTERIOR WOOD DESIGN OWNER G.C. LOUNGE SINK GRAINGER LOUNGE SINK & FAUCET OWNER G.C. LIGHT FIXTURE NOTE:ALTERNATES ARE NOT ACCEPTED AS THE FIXTURES MUST HAVE THE DESIGNATED GE ULTRAMAX BALLAST, REQUIRED BY TENANT FIXTURE SCHEDULE FIXTURE TYPE E SAM JONES PART # LITHONIA PART # NOTES 2X4 LAY IN 4 LAMP FIXTURE -LAMPS INCL 2GT8432Al2MVOS10 LP 2X4 LAY IN EM 4 LAMP -LAMPS INCL 2GT8332Al2MV1/3EL14 LP 4' SINGLE TUBE LOW PROFILE STRIP -NO LAMP Z132MVOLTGEUM ASYMMETRICAL REFLECTOR FOR STRIP FIXTURF-8ASR48 8' 4 LAMP STRIP FIXTURE W/DUAL REFLECTOR TLA232MVOLT1/4GEUM 4' T8 LAMP 21421 EXIT EXR LED M12 EMERGENCY WALL MOUNT EU2 LED EXIT / EMERGENCY COMBO MIGM SW3R N EXTERIOR DOOR EMERGENCY LIGHT INDX618 OCCUPANCY SENSOR LIGHT SWITCH 6FAA7 2GT8432Al2MVOLTGEUMG841 EXL28 4 LAMP GENERAL T8 TROFFER LAMPS INCLUDED. GE ULTRAMAX BALLAST 2GT8432Al2MVOLT1 / 3GEUMELG841 EXL28 GENERAL T8 TROFFER LAMPS INCLUDED. GE ULTRAMAX BALLAST 20OVEC GE ULTRAMAX BALLAST 180CKW NONE 105LR2 TLA232MVOLT1 / 4GEUM INDUSTRAILS GE ULTRAMAX BALLAST NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE CONTACTS ITEM VENDOR GRAINGER 941-753-3904 (OFFICE) ATTN: JOSE 941-504-5856 (CELL) GONZALEZ JOSE.1.GONZALEZ@GRAINGER.COM (EMAIL) E. SAM JONES 888-851-1955 (OFFICE) ATTN: LYN GREATREX 652-476-2498 (CELL) LGREATREX@ESAMJONES.COM (EMAIL) INTERIOR 941-7534445 EXT 11 WOODESIGNS (OFFICE) ATTN: MIKE MONAHAN CLEAR IMAGE 727-798-8032 SERVICE CLEARIMAGESERV@AOL.CO ATTN: JASON RICHKO M STANLEY ACCESS STANLEY ACCESS TECHNOLOGIES, INC. TECHNOLOGIES, INC 5479 SOAPSTONE PLACE ATTN: DONALD SARASOTA, FL 34233 HUNT P: 941-706-1248 F: 941-706-1348 DONALD. HUNT@SBDINC.COM FLORIDA TILE FLORIDA TILE ATTN: CHERYLE MUNDY 404-886-0556 CHERYLE.MUNDY@FLORIDATILE.COM ELECTRIC ELECTRIC WHOLESALERS WHOLESALERS 2475 17TH ST SARASOTA, FL ATTN: CRAIG HUFFMAN 34234 941-343-5300 C. H U FFMAN @ EWSARASOTA. COM ' CLEAR IMAGE SERVICE SHALL BE RESPONSIBLE FOR WAXING THE FLOORS AT TWO SEPARATE TIMES AS FOLLOWS: 1. STRIP AND CLEAN TILE. THEN APPLY FOUR COATS OF WAX. THIS SHALL BE COMPLETED PRIOR TO FIXTURE INSTALL. 2. AISLE TAPE WILL BE INSTALLED BY THE FIXTURE INSTALLERS. 3. TWO DAYS PRIOR TO STORE OPENING THE FLOOR SHALL BE SCRUBBED AND TWO MORE COATS OF WAX APPLIED. WAX USED SHALL BE SC JOHNSON VECTRA SERIES WAX WAX TO BE PROVIDED BY BEALLS / BURKES OUTLET BURKE'S OUTLET ROOM/ AREA FINISH SCHEDULE FLOOR BASE WALLS _ CEILING REMARKS MATERIALS MATERIALS MATERIAL FINISH AREAS MATERIAL MOUNTING HEIGHT 0_ w �U) ❑ NOTE: G.C. SHALL VERIFY O ❑ w 0 PAINT AREAS & COLORS W/ Q a� ❑ w ❑ u_ w o �U)F- B.O.S. PRIOR TO PAINTING W W W W ❑❑ cV D_ J Q d �_ Z) O z Y Z U J uJ U ch O z a� m m zZ wuJ z L_ ww w 2 ❑�Z ❑ w a ❑ F— �o �_� J �� QQ 06>o'U �� QQ ❑�F— ❑ z om 0 � z _ U z w O� m o_a z �00 �� 0 002 UQ �� z z Lu � 0 WOZ w (� z Q z C� OO U z�= 0_ w Q T m Q a U ❑ 0_ w ❑ Q w w � Z ❑ � Y � o� 2 _O F- ❑ `? 0- U U) 0- C) a 0 LU m 0 z �t � � � LuL4 o_ � O U��� Z Lu Lw � � Lu w w � o_ Ov w > m ww � � � w❑ ¢ z O� W � O 0 ❑ o_ N C.) WF- >- - U0 � � p 0(� W z Z Q� 0' 0' 00 W 0- U ❑ U � 0' ❑ 0- �r O z _J (n F= cn � � - �W = cn - U W � ILL U ❑ (D v m N O F � F U _ T to J � p �- W p (n > O m O O _ ❑ X� m ¢ 0 -� z J W Q O 0� o_ O O 0 O U) �- Q z LV oo 0 �Q bo `T t= O O 0' ~ X ❑_ 0 p 0 0❑d F-ww J� }� cF- > UO p �X O QO mU F: U aLL >-w ~ 0 wQ z W m F-- Q (_� o_ W z� M ❑W 00 2 ❑❑ v N M ~ U z W ❑ m- a U O X_z X ❑ 0 (9 cn (7 z 0_ w ❑ Z Zag _ ❑ z_ Qw m z_ _ pQ z_ 0_ 0 Q ❑ 0_ z o_ ❑ w o_ z 0 ❑ W a z 'v ❑ v 0 o_ z z 0 z H >> Q w ~ = J U ~_ �� �❑w ¢❑ ♦— �m i �M J F- m Q 0_ o_ U w m i'� W ~ N�F- N Q 0 LL WQ O W~ a (n W W fn (A ❑ (A F— Z Cn Z W a W �_ f— - Q_ (9 (0 - Q - v J Q Z F- z Z F— _ = �, H H Z Z Z z U) cA � 0 0_ (7 - z U) ❑ - — 0 z Z (n cn o_ Ow X 5 00 0' �s W J z i= U W U X W Q > 2 X w - LLF Q 0 cn X W 0- ?< w e0 } C� 50 C� bo W Q U F- J Q Q o_ Q W o_ > v a a Q 0_ X W LL1 z D LL X W co i X W W 0_ z o o W z W z 0- X W X w W z W z O cn F- ROOM/ AREA NAMES 101 SALES 1 V-2" 102 HALL 10'-0" 103 TLT 9'-01, 104 TLT + 9'-0" 105 LOUNGE 10'-0" 106 JAN O.T.D. 107 HALL 10'-01, 108 RECEIVING O.T.D. 109 COMPUTER 10'-01, ALL FINAL COLOR AND FINISH SELECTIONS SHALL BE APPROVED, IN WRITING, BY THE TENANT REPRESENTATIVE PRIOR TO PURCHASE AND/OR INSTALLATION. * OTD - OPEN TO DECK MATERIAL SCHEDULE ARK MATERIAL MANUFACTURER CATALOG NO. DESCRIPTION VCT-1 VINYL COMPOSITION TILE ARMSTRONG Standard Excelon Imperial Texture #51860 Soft Cool Gray SALES AREA, OFFICES, HALL & LOUNGE FLOORS CER-1 PORCELAIN TILE FLORIDA TILE 12"x24" RHYME 28532, DESERT HARMONY. FIELD, WALL AND FLOOR TILE REST ROOM - FIELD, WALL & FLOOR & CER-2 PORCELAIN TILE FLORIDA TILE 3"x12" BULLNOSE, RHYME 28532 P43C9, DESERT HARMONY REST ROOM - BULLNOSE TILE & D.F. VB-1 VINYL COVE BASE ARMSTRONG "CB LIGHT GRAY" #204 USE PRE -MOLDED CORNERS (1N & OUT) VB-2 VINYL COVE BASE MERSER "BLACK" #701 4" VINYL COVE BASE FITTING ROOMS INSIDE & OUTSIDE WP WALL PANELS INTERIOR WOOD DESIGN VICUNA MATCH FORMICA # 7198-58 P-1 PAINT SHERWIN WILLIAMS GLIDDEN / PORTER PAINTS SW6112 BISCUIT PPG 1095-2 GLAZED PEARS EXTERIOR PAINT COLOR EXTERIOR PAINT COLOR P-2 PAINT SHERWIN WILLIAMS GLIDDEN / PORTER PAINTS SW6115 TOTALLY TAN PPG 1081-4 CINNAMON FROST EXTERIOR PAINT COLOR, RESTROOMS EXTERIOR PAINT COLOR, RESTROOMS P-3 PAINT SHERWIN WILLIAMS PROMAR 200 B20W2251 PREMIX FACTORY - WHITE EGGSHELL ABOVE/BELOW WALL PANELS, MANAGER, UP, LOUNGE, STOCKROO P-4 PAINT SHERWIN WILLIAMS PROMAR 200 OIL BASE ALKALINE ENAMEL PREMIS FACTORY WHITE SEMI -GLOSS COLUMNS, HALLWAYS, DOORS P-5 PAINT SHERWIN WILLIAMS B65AO0775 ARMORSEAL FLOOR ENAMEL HAZE GRAY FLOOR PAINT P-6 PAINT HOME DEPOT STOP RED CASH WRAP WALLS, WALL PANELS AT FITTING ROOMS P-7 PAINT SHERWIN WILLIAMS SW 6093 " FAMILIAR BEIGE FITTING ROOMS TRIM ACT-1 CEILING ARMSTRONG Z-0" X 4'-0" LAY IN CORTEGA FRP FRP PANELS AND TRIMS WHITE JANITORS ROOM WALL BEHIND MOP SINK L-1 LAMINATE - RED WALL PANEL FORMICA STOP RED #839 L-2 LAMINATE - FITTING ROOM ARBORITE PEAR WOOD W-453 TP-1 POLYMER (HDPE) / GLOBAL PARTITIONS 9223 OLIVE TOILET / URINAL PARTITIONS TOILET PARTITIONS CG-1 PORCELAIN TILE GROUT CUSTOM BUILDING PRODUCTS - POLYBLEND #541 WALNUT PORCELAIN TILE SANDED GROUT SHERWIN WILLIAMS OR GLIDDEN/PORTER PAINT BRAND PAINT ONLY (EXCEPT P-6 BY HOME DEPOT) ALL PAINT FINISHES SHALL BE PRIMER & 2 FINISH COATS NOTE #1 PAINT SPEC: SHERWIN WILLIAMS - DURATION EXTERIOR ACRYLIC LATEX, SATIN FINISH GLIDDEN / PORTER PAINTS - PERMANIZER EXTERIOR ACRYLIC PAINT, SATIN FINISH 1 fl I ■ OF ■ %i REMARKS SUPPLIED & INSTALLED BY OWNER SUPPLIED & INSTALLED BY G.C. SUPPLIED TALLED BY G.C. SUPPLIED & INSTALLED BY OWNER SUPPLIED & INSTALLED BY OWNER SUPPLIED BY TENANT, INSTALLED BY G.C. SUPPLIED & INSTALLED BY G.C. SEE NOTE#1 SUPPLIED & INSTALLED BY G.C. SEE NOTE #1 SUPPLIED & INSTALLED BY G.C. SEE NOTE #1 SUPPLIED & INSTALLED BY G.C. SEE NOTE #1 SUPPLIED BY G.C. SUPPLIED BY G.C. SUPPLIED & INSTALLED BY G.C. SUPPLIED BY G.C. SUPPLIED BY G.C. SUPPLIED & INSTALLED BY G.C. SUPPLIED & INSTALLED BY G.C. SUPPLIED & INSTALLED BY G.C. SUPPLIED & INSTALLED BY G.C. SUPPLIED & INSTALLED BY G.0 SUPPLIED & INSTALLED BY G.C. STOP RED FORMULA CLRNT OZ 384TH CL 0 264 KXL 0 300 RUL 3 288 VUL 8 312 ■ ■ BEHR ULTRA BY HOME DEPOT BASE: 7753 PP ULTRA INT SATIN/SATIN WALLS WITH EXISTING GYPSUM WALL BOARD 1. INSTALL (4) FOUR ROWS OF FURRING STRIPS, TOP EDGE AT 10'-0" A.F.F., BOTTOM ROW RESTING ON SLAB. 2. TRIM FURRING STRIPS NEAR CORNERS AND OTHER AREAS NOT COVERED BY THE WALL SYSTEM. 3. WHEN INSTALLING WALL SYSTEM ON FRAMED WALLS, SECURE FURRING TO STUDS BEYOND GYPSUM BOARD. Lei P M L K J H G F REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: WBRC..s ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas W. Whitney AM BEALLS OUTLET #542 ZEPHYRHILLS B PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 FINISH SCHEDULE & SUPPLIES ITEMS LIST SHEET TITLE: WBRC CAD FILE: T103 Projects -Florida\3501-3600\3542M5 Bealls Outlet Zephyrhills FL\2 Design0wgs\Bldg\35421M5 BEALLS OUTLET ZEPHYRHILLS.M PROJECT No. 3542M5 GRAPHIC SCALE: O„ i I� SCALE: 1/4" = 1'-01, A PROJECT MANAGER: Approver SHEET No. DRAWN BY: Author A E 6 02 CHECKED BY: Checker lcaereic rzoo ws 1 2 ' 3 ' 4 ' 5 6 13 IM 17 18 19 20 Q 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 1 17 1 18 .w . t r 19 1 20 P 0 N M L K J H G F E u C B A PLUMBING PROJECT NOTES 1. THE CONTRACTOR SHALL ARRANGE AND PAY FOR ALL PERMITS 14. SANITARY PIPING SCHEDULES: AND INSPECTIONS REQUIRED IN THIS WORK. A) VENTS - SCHEDULE 40 PVC DWV. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, B) BUILDING DRAIN -SCHEDULE 40 PVC DWV. SPECIFICATIONS, LOCAL, STATE AND NATIONAL CODES. CERTIFICATES OF INSPECTION, WHERE REQUIRED, SHALL BE OBTAINED AND PAID 15. DOMESTIC WATER PIPING SCHEDULES: FOR BY THIS CONTRACTOR AND FURNISHED TO THE TENANT. INTERIOR ABOVE GRADE - TYPE "L" HARD DRAWN COPPER TUBE. 3. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EXTERIOR BELOW GRADE - TYPE "K" HARD DRAWN COPPER EQUIPMENT AND TOOLS TO PERFORM MECHANICAL WORK AS SHOWN, TUBE WITH FLARED FITTINGS. NOTED OR SCHEDULED FOR A COMPLETE INSTALLATION. 16, ALL VALVES AND SPECIALTY ITEMS MAY NOT BE SHOWN IN 4. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND COMMERCIAL EVERY INSTANCE ON THE DRAWINGS, BUT ARE TO BE PROVIDED GRADE. WHETHER SHOWN OR NOT WHEN NECESSARY FOR PROPER OPERATION AND MAINTENANCE OF THE SYSTEM. UNLESS 5. THE CONTRACT DRAWINGS INDICATE THE EXTENT AND GENERAL OTHERWISE NOTED, VALVES AND SPECIALTY ITEMS ARE TO BE ARRANGEMENTS OF EQUIPMENT AND SYSTEMS. IF ANY DEPARTURES RATED AT 125 PSIG. DEVICES AND VALVES 2 1/2" AND SMALLER ARE FROM THE CONTRACT DRAWINGS ARE DEEMED NECESSARY BY THE TO HAVE SOLDERED OR SCREWED CONNECTIONS. CONTRACTOR, DETAILS OF SUCH DEPARTURES AND REASONS THEREFORE SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. 17. PIPING SYSTEM INSULATION: POTABLE COLD WATER PIPING - ALL PIPING ABOVE CEILING OR EXPOSED TO THE EXTERIOR WITH 1" THICK FIBERGLASS OR 1/2" 6 IT IS THE INTENT OF THE PLANS AND SPECIFICATIONS TO PROVIDE FLEXIBLE UNICELLULAR. A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL POTABLE HOT WATER. - ALL SUPPLY PIPING WITH 1" THICK OBVIOUSLY NECESSARY ITEMS EVEN THOUGH SOME ITEMS MAY NOT BE INDICATED ON THE DRAWING OR SPECIFICATIONS. FIBERGLASS OR 1/2" THICK FLEXIBLE UNICELLULAR, EXCEPT THE FIRST EIGHT LINEAL FEET OF HOT WATER SUPPLY PIPING SHALL BE 7. ALL OBVIOUS ERRORS AND/OR OMISSIONS IN THE ABOVE MENTIONED MINIMUM OF 1" THICK INSULATION. DOCUMENTS SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT / SANITARY- ALL PIPING EXPOSED TO THE EXTERIOR WITH 2" THICK ENGINEER PRIOR TO CONSTRUCTION. FIBERGLASS OR 1" FLEXIBLE UNICELLULAR. 18. FIXTURES: 8. THIS CONTRACTOR SHALL INSPECT THE JOB SITE WHERE THE A) PLUMBING FIXTURES SHALL BE FURNISHED AND WORK IS TO BE PERFORMED AND SHALL AQUAINT THEMSELF WITH THE CONDITIONS UNDER WHICH IT SHALL BE EXECUTED. INSTALLED IN ACCORDANCE WITH THE SCHEDULE AS SHOWN ON THE PLANS. ALL FIXTURES SHALL BE COMPLETE WITH HANGERS, 9. PROVIDE DIELECTRIC UNIONS OR FITTINGS WHENEVER FERROUS CARRIERS, TRIM, STOP VALVES AND OTHER ACCESSORIES AS AND NON-FERROUS PIPES ARE JOINED. REQUIRED TO OBTAIN A COMPLETE INSTALLATION. B) AMERICANS WITH DISABILITIES ACT (A.D.A.): ALL HANDICAP FIXTURES AND TRIM SHALL COMPLY WITH FEDERAL AND STATE 10. PROVIDE ACCESS DOORS WHERE NECESSARY TO SERVICE SEALS, ACCESSIBILITY CODES. NOTE: WATER CLOSET FLUSH VALVE VALVES, TRAPS, CLEANOUTS, WATER HAMMER ARRESTORS, ETC. CONTROLS SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET AREAS NO MORE THAN 44 INCHES ABOVE THE FLOOR. 11. CONTRACTOR TO VERIFY SIZE AND LOCATIONS OF ALL EXISTING SERVICES PRIOR TO COMMENCING WITH NEW WORK. 19. ALL PIPING INSTALLED ON THE PROJECT SHALL BE COORDINATE ALL CLEANOUTS WITH ARCHITECTURAL PRIOR TO HYDRAULICALLY TESTED, FLUSHED AND DISINFECTED. INSTALLATION. 20. .ALL PARTS, MATERIAL, EQUIPMENT AND LABOR FURNISHED 12. EVERY TRAP SHALL BE PROTECTED AGAINST SYPHONING AND SHALL BEAR A ONE (1) YEAR, NO COST TO B.O.S., WARRANTY FROM BACK PRESSURE. AIR CIRCULATION SHALL BE ASSURED BY MEANS DATE OF FINAL ACCEPTANCE. THE PLUMBING CONTRACTOR SHALL OF A SOIL OR WASTE STACK VENT, A CONTINUOUS SOIL OR WASTE PROVIDE ALL OF THE ABOVE WARRANTY REQUIREMENTS IN A VENT OR CIRCUIT VENT. WRITTEN STATEMENT ALONG WITH EQUIPMENT MANUFACTURER'S WARRANTIES. 13. ALL VENT PIPES PASSING THROUGH THE ROOF SHALL BE FLASHED AS REQUIRED BY GENERAL CONTRACTOR. 20. VERIFY EXISTING LOCATIONS AND INVERTS OF PIPING. VB O O 3/4" COLD WATER SUPPLY BALL VALVE (TYP) AMTROL EXPANSION 6 ABSORBER #AST-5 3/4" 12 O 13 3/4" 3/4" 3/4" 3d 110 DEGREE F HOT WATER SUPPLY 7 O REFER PLUMBING SCHEDULE (WH-1). 14 O 11 32" O2 PROVIDE HEAT TRAP (MIN. 12" OFFSET). O 3/4" -I I O T & P RELIEF VALVE. 7 3/4" PRESSURE TYPE VACUUM BREAKER. O O® 7 6 (D BALL & CHECK VALVE ©WATER HEATER WALL MOUNT PLATFORM WITH INTEGRAL DRAIN PAN. OHOLDRITE MODEL 40-SWHP-W. 9 10 FACTORY ENGINEERED MOUNTING 7 HARWARE INCLUDED WITH ASSEMBLY. O G.C. SHALL PROVIDE BLOCKING AND STUDS FOR SUPPORT AS REQUIRED BY MFR. 1" (DDIELECTRIC UNION MOUNT AS O ROUTE AND OFFSET DRAIN LINE FULL SIZE HIGH AS AND AIR GAP 2" ABOVE MOP SINK BOTTOM. POSSIBLE 10 ROUTE AND OFFSET T&P LINE FULL SIZE NI AND AIR GAP 4" ABOVE MOP SINK BOTTOM. 11 MIXING VALVE - 80°F THRU 120°F 12 THERMOMETER. TRERICE #AO0507 W/ #138-0015.2 WELL MOP SINK 13 BALL VALVE FINISH FLOOR 14 ELECTRICAL BY ELECTRICAL CONTRACTOR. ., a , ELECTRICAL WATER HEATER DETAIL NO SCALE FINISHED FLOOR FLOOR DRAIN FLASHING r , s L . • a. • IIIII e s." L ' e • s s a L s TRAP PRIMER PIPING UNION TRAP PRIMER CONNECTION DETAIL NOT TO SCALE ENSURE NO OFFSETS L: OR SLOPE MORE THAN 2%. Twh L '. TAILPIECE OD TUBING SLIP JOINT CHROME WALLCOVEF AND SCREN, "WCO" WALL CLEANOUT DETAIL NOT TO SCALE "P"TRAP DETAIL NOT TO SCALE PLUMBING FIXTURE UNIT SCHEDULE QUANTITY DESCRIPTION WATER DEMAND SANITARY FIXTURE UNIT (F.U.) (EACH) FIXTURE UNITS (TOTAL) FIXTURE UNIT (F.U.) COLD HOT COMB. COLD HOT COMB. F.U. (EACH) F.U. (TOTAL) 1 DRINKING FOUNTAIN 0.25 0 0.25 0.25 0.00 0.25 1.50 1.50 2 FLOOR DRAINS 0 0 0 0.00 0.00 0.00 2.00 4.00 2 LAVATORY (PUBLIC) 1.50 1.50 2.00 3.00 3.00 4.00 2.00 4.00 1 SERVICE SINK 2.25 2.25 3.00 2.25 2.25 3.00 2.00 2.00 2 WATER CLOSET, PUBLIC FLUSH TANK 5 0 5 10.00 0.00 10.00 4.00 8.00 1 KITCHEN SINK 1.00 1.00 1.40 1.00 1.00 1.40 2.00 2.00 0 URINAL 5.00 0 5.00 0.00 0.00 0.00 2.00 0.00 9 TOTAL: 1&50 6.2,'i 1&65 - 21.50 NOTES: 1) SYSTEM WILL REQUIRE 1" WATER MAIN. 1" EXISTING. 2) SYSTEM WILL REQUIRE A MINIMUM 3" BUILDING DRAIN (1/8" SLOPE). 4" INSTALLED.. B.O.S. PLUMBING FIXTURE SCHEDULE MARK DESCRIPTION FIXTURE MFG. CATALOG NO. TRIM MFG. CATALOG NO. REMARKS NOTE CONNECTION SIZES W V C H WC-1 HL WATER CLOSET-ADA-LEFT SIDE FLUSH VALVE AMER. STD. 3043.001 SLOAN 111-YBYC-YO OLSONITE SEAT #95-SS, 3/8" BRASS BOLTS 3 3" 2" 1" - - WCA HR WATER CLOSET-ADA-RIGHT SIDE FLUSH VALVE AMER. STD. 3043.001 SLOAN 111-YBYC-YO OLSONITE SEAT #95-SS, 3/8" BRASS BOLTS 3 3" 2" 1" - - L-1 H LAVATORY - WHITE - WALL HUNG - HANDICAP AMER. STD. 0355.012 SYMMONS S-20-2-G-FR-VP Z-1231-79 CARRIER 1-2-3-5 2" 2" 1/2" 1/2" EWC-H ELECTRIC WATER COOLER - HANDICAP ELKAY EZSTL-8-C ELKAY LKAPR-EZL ADA APRON 1-2-3 2" 2" 1/2" - MS FLOOR MOP SINK 24"X24"X10" MUSTEE 63M MUSTEE 63.600A 63CM KIT -SINK, FAUCET, HOSE, MOP HANGAR, STRAINER, PIPE SEAL 1-2-6 3" 2" 1/2" 1/2" CS COUNTER SINK, 5 1/2" DEEP MOUNT IN COUNTER SURFACE ELKAY LRAD1918553 AMER. STND. 6409.170.002 PROVIDE DRAIN STRAINER, RECESS MOUNT, 3-HOLE 4" O.C. 1-2 2" 2" 1/2" 1/2" RW REFRIGERATOR WATER CONNECTION -HAMMER VALVE OATEY 39152 (1 ONLY) MAKE CONNECTION TO OWNER PROVIDED REFRIGERATOR - - - - 1/2" - - BV BALL VALVE APOLLO 70-200 AS REQUIRED BY PLAN. - - - - - - - WCO WALL CLEANOUT ZURN Z1446 PVC PLUG WITH BRONZE INSERT W/THREADS TO MATCH COVER - - - - - - - - FD FLOOR DRAIN ZURN ZS415NL-VP-P INSTALL FLUSH WITH FINISHED FLOOR. CONNECT TO TRAP PRIMER (TP) 3" - - TP TRAP PRIMER PPP P-1 -- - 1/2" -- VB VACUUM BREAKER - PRESSURE TYPE WATTS N36 LOCATE & SIZE AS PER MFG. INSTRUCTIONS WHA WATER HEATER - ELECTRIC - 20 GAL. - 2KW NON-SIM. RHEEM EGSP20 SEE DETAIL. (208V) - - - - - - PLUMBING NOTES: GENERAL NOTES: (1) MCGUIRE CAST BRASS P-TRAP WITH TUBULAR WALL BEND (SIZE AS REQUIRED). P-TRAPS IN CONCEALED (A) ALL PLUMBING FIXTURES SHALL BE WHITE. SPACES MAY BE PVC. (B) PROVIDE ONLY PRIOR APPROVED MANUFACTURERS. (2) MC GUIRE LAWSINK SUPPLY STOP #H2165CCLK WITH CHROME RISER TUBE. (C) SEE ARCHITECTURAL DRAWINGS FOR TOILET ACCESSORIES (SOAP DISPENSERS, DRYERS, ETC. AND ELEVATIONS. (3) SET AT HANDICAP HEIGHT. (D) VERIFY PIPE SIZES FOR "BV", "FD", "ECO", "WCO" OR OTHER COMPONENTS. (4) REQUIRED IN MEN'S AND WOMEN'S TOILET ROOM UNDER LAVATORY. (E) KOHLER MAY BESUBSTITUTED FOR AMERICAN STANDARD PLUMBING FIXTURES. (F) BENEKE MAY BE SUBSTITUTED FOR OLSONITE SEATS. (5) TRUEBRO LAV GUARD: MODEL NO. 102W FOR P-TRAP AND ANGLE STOPS WITH SUPPLY ASSEMBLIES. (G) BRASSCRAFT MAY BE SUBSTITUTED FOR MCGUIRE. MODEL NO. 102W WITH 105 ACCESSORY FOR OFFSET DRAIN. (6) PROVIDE THE MUSTE 63CM KIT THAT PROVIDES THE MOP SINK(63M), FAUCET / FAUCET HANGER(63.600A), HOSE AND HOSE HOLDER BRACKET(65.700), DRAIN SEAL(65.309), STRAINER(INCL.W/ SINK), AND MOP HOLDER BRACKET(65.600). KIT AVAILABLE AT GRAINGER, GRAINGER #11 U264. 1 ' 2 3 ' 4 1 5 6 7 8 9 10 MAY EXTEND AS A WASTE OR VENT WALL PLUGGED TEE WITH CLEANOUT FLOOR LINE 1/8" C.I. BEND _ BALANCE OF PIPING SAME AS CLEANOUT OT GRADE IE F TREADS CONNECT TO TEES AS REQUIRED 12 2 V /Ole ^\ /// 1 \ 2"V \ REUSE EXISTING r 1 \� ROOF PENETRATION i \ 3" VTR \ \ 3 V I I I \\ I I \ I CONNECT TO EXISTING SITE I 2"V 1 \ SANITARY. FIELD VERIFY I I \\ 1 EXACT LOCATION, INVERT I 4 I 12"V \ v \ I \ \ AND FLOW DIRECTION. 1 \ 3"V I 1 \ 1 100, \\ z"v 1 i I \\\ le� 001 \ I I EWC-H 2„ MS1 2" 3" 13 14 15 IR WCO 16 D 3" SANITARY RISER NOT TO SCALE ME3 CONSULTING ENGINEERS, LLC 5300 Paylor Lane Sarasota, FL 34240 Tel:941-748-1319 Fax:941-361-1221 www.me3-engr.com sidney@me3-engr.com Designed: BAK ME3 Job No: B17-1166 Checked: BAK Date: 09/29/2017 Drawn: KCC C.O.A.27552 Copyright 2017 ME3 All rights reserved P IN N M L K J H G F REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: "To the best of the Architect's or Engineer's knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by local authority in accordance with Chapter 553 and 663 of Florida Statutes." (17 Kay C. Clem Florida License # 53270 WBRCIENI. ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA BEALLS OUTLET #542 ZEPHYRHILLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B SHEET TITLE: WBRC CAD FILE: PROJECT No. 3542XX GRAPHIC SCALE: 0„ SCALE: As Indicated I I A PLUMBING PLAN PROJECT MANAGER SHEET No. 1 /4" _ 1 i_Off N DRAWN BY: P 101 CHECKED BY: 17 18 19 20 PLUMBING PLAN s Q 1 I 2 I 3 1 4 I 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 1 17 1 18 19 1 20 Im 1 P 0 N M L KI J H G FI E D c B AI 3 4 6 7 LOUVER SCHEDULE MARK MANUF MODEL LIST SIZE (LAN) CFM MIN FREE AREA MAX VEL ACCESSORIES DESCRIPTION LV-1 GREENHECK ESS-501 D 24x12 225 .39 SF 700 FPM BIRDSCREEN SIGHTPROOF STATIONARY LOUVER ALL LOUVERS TO HAVE FLANGES. ALL LOUVERS MUST MEET LOCAL WIND REQUIREMENT. EXHAUST FAN SCHEDULE MARK MANUFACTURER MODEL CFM ESP DRIVE PEED/SONES ELEC WATTS DESCRIPTION NOTES EF-1 GREENHECK SP-B110 75 0.5 DIRECT 801 / 1.5 120/1/60 80 CEILING EXHAUST FAN 1, 2, 3 EF-2 GREENHECK SP-B110 75 0.5 DIRECT 801 / 1.5 120/1/60 80 CEILING EXHAUST FAN 1, 2, 3 EF-3 I GREENHECK SP-B110 75 l 0.5 DIRECT 1 801 / 1.5 1 120/1/60 1 80 CEILING EXHAUST FAN 1, 2, 3 ACCEPTABLE MANUFACTURERS ARE: FANTECH, COOK, GREENHECK, AND PENN. NOTES: 1 WITH FACTORY MOUNTED SPEED CONTROLS. ADJUST TO MATCH CFM SHOWN. 2 PROVIDE BACKDRAFT DAMPER AT FAN OUTLET 3 FANS TO BE OPERATED BY LIGHTING MOTION SWITCH, SEE ELECTRICAL PLANS. SET FOR MINIMUM 10 MINUTE DELAY. 8 ' 9 10 SET THE THERMOSTAT LOCKOUT OPTION USING THE FOLLOWING PROCEDURE. SET LOCKOUT OPTION #1 (TEMPORARY OCCUPIED / UNOCCUPIED) Proper keypad sequences activate the lockout features. To change the keypad lockout state: 1. Enter Installer Setup: press and hold both the Run Schedule and Copy keys until DEG F displays. 2. Press Q until KYLCK displays. 3. Use the up ♦ or down ♦ key to change the setting. Options are: • 0: No lockout • 1: Lockout all keys except Temporary Occupied, Temporary Not Occupied, up ♦ , down ♦ and(D • 2: Lockout all keys except ( . NOTES: - Options 1 and 2 do not allow adjustments on dehumidification high limit. -- No options lockout special keypresses. See the Special Functions section for details. 4. Once the proper option is chosen, exit Installer setup by pressing Run Schedule. 5. The display prompts SAVE CFG (save configuration). If you want to save it, use the up ♦ or down ♦ key to change NO to YES before pressing Run Schedule again 12 THERMOSTAT HEATING & COOLING SCHEDULE MANUFACTURER: HONEYWELL MODEL: 173508 GRANGER PART NUMBER: I 1YMG4 COOLING HEATING OCCUPIED SET POINT 72 DEGREES OCCUPIED SET POINT 70 DEGREES UNOCCUPIED SET POINT 178 DEGREES UNOCCUPIED SET POINT 165 DEGREES OCCUPIED TIMES DAY OF WEEK ON OFF MONDAY-SATURDAY 8 AM 19745 PM SUNDAY 110 AM 8:45 PM OCCUPIED TIMES DAY OF WEEK ON OFF MONDAY-SATURDAY 8 AM 9:45 PM SUNDAY 110 AM 8:45 PM HOLDAY'S TO BE SCHEDULED AS UNOCCUPIED SET POINT EASTER THANKSGIVING CHRISTMAS APRIL 16 2017 NOVEMBER 23 2017 DECEMBER 25 2017 APRIL 1 2018 NOVEMBER 22 2018 DECEMBER 25 2018 APRIL 21 2019 NOVEMBER 28 2019 DECEMBER 25 2019 APRIL 12 2020 NOVEMBER 26 2020 DECEMBER 25 2020 APRIL 4 2021 NOVEMBER 25 2021 DECEMBER 25 2021 APRIL 17 2022 NOVEMBER 24 2022 DECEMBER 25 2022 APRIL 9 2023 NOVEMBER 23 2023 1 DECEMBER 25 2023 1. THERMOSTATS SUPPLIED BY B.O.S., INSTALLED AND CONNECTED BY CONTRACTOR. 2. REPLACE EXISTING THERMOSTATS WITH NEW THERMOSTATS AND INSTALL NEW CABLE TO RTU. 3. PROGRAM THERMOSTATS AS INDICATED ON THIS SCHEDULE. 4. PROGRAM THERMOSTATS FOR DAYLIGHT SAVINGS TIME, VERIFY DATES FOR EACH YEAR. 5. O/A DAMPERS SHALL CLOSE IN UNOCCUPIED MODE. 6. PROGRAM LOCKOUT OPTION #1 AS INDICATED AT LEFT. 13 14 15 MECHANICAL LEGEND AND NOTES RTU'S ARE EXISTING. REPLACE ALL FILTERS. DUCTWORK IS NEW AND EXISTING. NEW DUCTWORK SHALL BE METAL OR FLEX WITH R-6 INSULATION. INSTALLATION AND MATERIAL SHALL COMPLY WITH ALL ENERGY REQUIREMENTS. INSTALL NEW THERMOSTATS WHERE SHOWN AND CONNECT TO RTU'S. THERMOSTATS SUPPLIED BY B.O.S., INSTALLED AND WIRED BY CONTRACTOR. PROGRAM THERMOSTATS AS SCHEDULED. TRUNK DUCTS MAY BE THE EQUIVALENT RECTANGULAR SIZE. DUCT SMOKE DETECTORS AND TEST / RESET DEVICES ARE SHOWN ON THE FIRE ALARM DRAWINGS. SEE FIRE ALARM DRAWINGS FA101, FA102 AND FA103 FOR REQUIREMENTS AND INSTALLATION. DEVICES ARE SUPPLIED AND INSTALLED BY FIRE ALARM CONTRACTOR. THERMOSTAT. UNIT © CONTROLLED AS INDICATED. INSTALL AT 48" AFF F.D. FIRE DAMPER - SEE DETAIL —�V LOUVER i� DUCT UP DUCT DOWN VOLUME DAMPER i TRANSITION 16 CD CEILING DIFFUSER SR SIDEWALL REGISTER CR CEILING REGISTER RG RETURN GRILLE DRG DUCT MTD. RETURN GRILLE SRG SIDEWALL RETURN GRILLE DR DUCT MOUNTED REGISTER EG EXHAUST GRILLE AFF ABOVE FINISHED FLOOR MECHANICAL PLAN N 1 /8" = 1 --0" 17 18 CONSULTING ENGINEERS, LLC 5300 Paylor Lane Sarasota, FL 34240 Tel: 941-748-1319 Fax: 941-361-1221 www.me3-engr.com Sidney@me3-engr.com Designed: BAK ME3 Job No: B17-1166 Checked: BAK Date: 09/29/2017 Drawn: KCC C.O.A.27552 Copyright 2017 ME3 All rights reserved P IN N M L J H G F REV. DESCRIPTION I DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: "To the best of the Architect's or Engineer's knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by local authority in accordance with Chapter 553 and 663 of Florida Statutes." C D l°�q /l ? Kay C. Clem Florida License # 53270 WBR(IIIIIIII10C ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA BEALLS OUTLET #542 ZEPHYRHILLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B MECHANICAL PLAN SHEET TITLE WBRC CAD FILE PROJECT No. 3542XX GRAPHIC SCALE: On � u SCALE: As Indicated I I A PROJECT MANAGER: SHEET No. DRAWN BY: M 101 CHECKED BY: 19 20 Q 1 1 2 1 3 1 4 1 5 I 6 1 7 I 8 1 9 1 10 1 11 1 12 1 13 1 14 15 1 16 1 17 18 1 19 1 20 C P 0 N M L K J H G F E 9 C B A NOTES: 1. THESE DUCT FITTINGS SHALL BE USED UNLESS OTHERWISE NOTED. 45 DEG MAX. OO 30 DEG CONCENTRIC TRANSITION MAX. ECCENTRIC TRANSITION ASHRAE #3-5 RADIUS W R ASHRAE #3-6 MITERED 1000 FPM MAX ASHRAE #3-1 RADIUS D a ASHRAE #6-33 SYMETRICAL WYE VOL DAMPER R = 3W/2 RECTANGULAR ELBOWS RECTANGULAR ELBOWS R = 3D/2 ROUND ELBOWS SPUTTER DUCT ASHRAE #6-29 TEE WITH 45 DEG ENTRY ASHRAE #6-27 CONICAL TEE ASHRAE #6-10 90 DEG CONICAL TEE ASHRAE #6-11 45 DEG CONICAL WYE RECTANGULAR TRUNK RECTANGULAR TAP RECTANGULAR TRUNK ROUND TAP ROUND TRUNK ROUND TAP ROUND TRUNK ROUND TAP ACCEPTABLE DUCT FITTINGS MECHANICAL PROJECT NOTES 1. THE CONTRACTOR SHALL ARRANGE AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED IN THIS WORK. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONS, LOCAL, STATE AND NATIONAL CODES. CERTIFICATES OF INSPECTION, WHERE REQUIRED, SHALL BE OBTAINED AND PAID FOR BY THIS CONTRACTOR AND FURNISHED TO THE TENANT. 3. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM MECHANICAL WORK AS SHOWN, NOTED OR SCHEDULED FOR A COMPLETE INSTALLATION. 4. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND COMMERCIAL GRADE. 5. THE CONTRACT DRAWINGS INDICATE THE EXTENT AND GENERAL ARRANGEMENTS OF EQUIPMENT AND SYSTEMS. IF ANY DEPARTURES FROM THE CONTRACT DRAWINGS ARE DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH DEPARTURES AND REASONS THEREFORE SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. 6. IT IS THE INTENT OF THE PLANS AND SPECIFICATIONS TO PROVIDE A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL OBVIOUSLY NECESSARY ITEMS EVEN THOUGH SOME ITEMS MAY NOT BE INDICATED ON THE DRAWING OR SPECIFICATIONS. 7. ALL OBVIOUS ERRORS AND/OR OMISSIONS IN THE ABOVE MENTIONED DOCUMENTS SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT / ENGINEER PRIOR TO CONSTRUCTION. 8. THIS CONTRACTOR SHALL INSPECT THE JOB SITE WHERE THE WORK IS TO BE PERFORMED AND SHALL AQUAINT THEMSELF WITH THE CONDITIONS UNDER WHICH IT SHALL BE EXECUTED, REVIEW EXISTING SYSTEMS FOR CAPACITY AND AREA SERVED. NOTIFY ENGINEER IF DISCREPENCIES ARE FOUND OR IN CONFLICT WITH NEW PLAN. 9. ROOFTOP UNITS ARE EXISTING. REPLACE ALL FILTERS. 10. DUCT DIMENSIONS SHOWN ON THE DRAWINGS ARE CLEAR INSIDE "FREE AREA" DIMENSIONS. 11. PROVIDE CONICAL SPIN -IN OR PRESSURE FITTINGS WITH VOLUME DAMPER AT ALL FLEXIBLE DUCT RUNOUTS TO DIFFUSERS. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE T-0". 12. METAL DUCTS WHICH PENETRATE RATED FIRE WALLS AND ARE LESS THAN 100 SQ. INCHES SHALL EXTEND A MINIMUM OF 5 FEET ON BOTH SIDES OF THE WALL WITHOUT AN OPENING (TO PRECLUDE THE REQUIREMENT OF A FIRE DAMPER). DUCTWORK SHALL IN NO CASE BE LIGHTER THAN 24 GAUGE STEEL. PENETRATIONS GREATER THAN 100 SQ. INCHES SHALL REQUIRED A FIRE DAMPER. 13. PROVIDE IDENTIFICATION OF THE LOCATION OF ALL FIRE AND BALANCING DAMPERS. IDENTIFICATION TAGS SHALL BE AFFIXED TO THE WALLS OR CEILINGS AND SHALL BE VISIBLE FROM THE OCCUPIED SPACE. 14. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS AND RECOMMENDATIONS. 15. ALL INSULATION SHALL BE FIRE RATED IN ACCORDANCE WITH ASHRAE 90A 50/25 SMOKE DEVELOPMENT AND FLAME SPREAD REQUIREMENTS. INSULATION "R" VALUES SHALL COMPLY WITH ENERGY CODES. 16. MOUNT THERMOSTATS WHERE INDICATED ON PLANS, AT 60" CL. A.F.F. NEW THERMOSTATS SUPPLIED BY B.O.S., INSTALLED BY CONTRACTOR. INSTALL NEW CABLE TO ASSOCIATED RTU. PROGRAM NEW THERMOSTAT'S AS INDICATED. 17. DUCTWORK IS TO BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SMACNA MANUALS TO 2" PRESSURE CLASS FOR SUPPLY UPSTREAM OF TERMINAL UNITS, 1" PRESSURE CLASS FOR DOWNSTREAM OF TERMINAL UNITS AND 1" NEGATIVE PRESSURE CLASS FOR RETURN, SEAL CLASS "A" AND THE FOLLOWING SCHEDULE: A) RECTANGULAR DUCTS - GALVANIZED SHEET METAL WITH A MINIMUM 2" THICK, 1# DENSITY EXTERNAL DUCT WRAP. B) RIGID ROUND DUCTS - GALVANIZED SHEET METAL WITH A MINIMUM 2" THICK, 1# DENSITY EXTERNAL INSULATION. C) FLEXIBLE ROUND DUCTS -FLEXIBLE, WIRE REINFORCED DUCT WITH EXTERNAL INSULATION WITH VAPOR BARRIER AND FOIL FACED. MAXIMUM FLEXIBLE DUCT LENGTH TO BE T-0". D) EXHAUST AND OUTSIDE AIR DUCT - GALVANIZED SHEET METAL, NON -INSULATED. E) DUCT WRAP INSULATION - NOTED ABOVE MUST COMPLY WITH ENERGY EFFICIENCY CODES. THE INSULATION MUST HAVE A MINIMUM INSTALLED R = 6.0. 18. PORTIONS OF DUCTWORK VISIBLE THROUGH GRILLS, REGISTERS, AND DIFFUSERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. 19. UNLESS OTHERWISE NOTED, INSTALL ALL DUCTWORK AS HIGH AS POSSIBLE, TIGHT TO THE BOTTOM OF THE STRUCTURE. COORDINATE ELEVATION AND LOCATION WITH RAIN LEADERS, WATER PIPING, PLUMBING VENTS, AND MAJOR ELECTRICAL CONDUITS OR CABLE TRAY. 20. PROVIDE BALANCING DAMPER IN EACH BRANCH CONNECTION. 1 ' 2 ' 3 ' 4 ' 5 ' 6 ' 7 18 9 ' 10 1/4" DIA. STEEL unnin�n rr�no METAL DUCT STRAPR 60" MAX UNLESS FLOOR STRAP IS PLACED UNDER A BOTTOM REINFORCEMENT. 1" SCREWS SCREWS MAY BE OMITTED IF HANGER LOOPS SECURE WIRE LOAD RATED FASTENERS 6 10" DIA. MAX 24" DIA. MAX DUCT HANGARS NO SCALE OPEN ULILINU MOUNTING SIMILAR ICEILING EXHAUST FAN DETAIL I NO SCALE SPIN —IN FITTING WITH SUPPORT WIRE TO BUTTERFLY DAMPER & PREVENT SAGS & 45 DEG. EXTRACTOR KINKS IN FLEX —SUPPORT AS PER SMACNA STANDARDS —][ROUND "SNAPLOCK" SHEET METAL FOR RUNOUTS GREATER THAN 5FT., WITH WRAP INSULATION. AN APPROVED ALTERNATE IS "SPIRO—PIPE", / ESPECIALLY FOR LONG RUNS. 2" WRAP INSULATION: SUPPLY DUCT CUT, FIT & GLUED OVER CEILING DIFFUSER —\ WRAP INSULATION FLEXIBLE DUCT- DO NOT SAG OR KINK, INSULATED, MAXIMUM 5 FT. LONG THREE SHEET METAL / SCREWS THELIX OF FLEXIBLE DUCT, � BAND CLAMP &TAPED CEILING '/ CEILING DIFFUSER) NOTES: 1. DIFFUSER —TRANSITION ASSEMBLY TO BE SUPPORTED FROM STRUCTURE ABOVE. 2. THERE SHALL BE NO INSULATION EXPOSED TO THE AIRSTREAM. CEILING DIFFUSER RUNOUT DETAIL NO SCALE SQUARE DIFFUSER NECK MUST BE CONNECTED TO HARD DUCT OR TO FLEXDUCT BY MEANS OF A MINIMUM 12" DEEP SQUARE -TO -ROUND NECK TRANSITION ROUND DIFFUSER NECK TO BE CONNECTED TO HARD DUCT OR TO FLEXDUCT CEILING DIFFUSER CD-9x9 - DIFFUSER NECK SIZE 290 C�FM DESIRED AIR QUANITY �— MANUFACTURER: METAL*AIRE MODEL: 5000 MANUFACTURER: TITUS MODEL: TDC-AA ARROWS INDICATE BLOW PATTERN CONNECTING i INSULATE INSULATED SQUARE TO FLEX DUCT / ROUND TRANSITION WITH / NOTE: 2" THICK, 1# DIFFUSER ASSEMBLY / / DENSITY TO BE SUPPORTED / EXTERNAL DUCT FROM STRUCTURE WRAP. ABOVE. / INSULATE BACK OF DIFFUSER WITH 2" THICK, 1# DENSITY EXTERNAL DUCT WRAP. / NOTE: THERE SHALL BE NO INSULATION SUPPLY SUSPENDEErf EXPOSED TO THE AIRSTREAM. DIFFUSER CEILING TEE LAY -IN SUPPLY DIFFUSER DETAIL NO SCALE MANUFACTURER: METAL*AIRE MODEL:CC5 MANUFACTURER: TITUS MODEL: 50F RETURN GRILLE RG-22x22 — GRILLE NECK SIZE 1000 CFM DESIRED AIR QUANITY ARROW INDICATE DIRECTION OF AIR FLOW CONNECTING INSULATED FLEX DUC INSULATE / INSULATED OUTSIDE OF DIFFUSER DIFFUSER BOX / / BOX WITH WRAPPED INSULATION. TRANSFER / INSIDE OF BOX TO / GRILLES BE PAINTED BLACK SIMILAR / / 12" MIN /EGGCRATE SUSPENDED CEILING TEE J GRILLE LAY -IN TILE NOTE: THERE SHALL BE NO INSULATION EXPOSED TO THE AIRSTREAM. LAY -IN RETURN GRILLE DETAIL NO SCALE MECHANICAL LEGEND AND NOTES RTU IN EXPANDED AREA ARE EXISTING NEW. NEW RTU IS SUPPLIED BY BEALLS OUTLET, INSTALLED AND CONNECTED BY CONTRACTOR. ALL RTU'S AND SPLIT SYSTEM IN EXISTING STORE ARE EXISTING. ALL DUCTWORK IN EXPANDED ARE IS NEW. NEW DUCTWORK SHALL BE METAL OR FLEX WITH R-6 INSULATION. INSTALLATION AND MATERIAL SHALL COMPLY WITH ALL ENERGY REQUIREMENTS. ALL DUCTWORK AND GRILLES IN EXISTING STORE ARE EXISTING. RELOCATE GRILLES INDICATED. INSTALL NEW THERMOSTAT WHERE SHOWN AND CONNECT TO RTU'S. THERMOSTAT SUPPLIED BY B.O.S., INSTALLED AND WIRED BY CONTRACTOR. PROGRAM THERMOSTATS AS SCHEDULED. TRUNK DUCTS MAY BE THE EQUIVALENT RECTANGULAR SIZE. DUCT SMOKE DETECTORS AND TEST / RESET DEVICES ARE SHOWN ON THE FIRE ALARM DRAWINGS. SEE FIRE ALARM DRAWINGS FOR REQUIREMENTS AND INSTALLATION. DEVICES ARE SUPPLIED AND INSTALLED BY FIRE ALARM CONTRACTOR. THERMOSTAT. UNIT CONTROLLED AS INDICATED. INSTALL AT 48" AFF F.D. FIRE DAMPER - SEE DETAIL CD CEILING DIFFUSER LV SR SIDEWALL REGISTER LOUVER CR CEILING REGISTER DUCT UP RG RETURN GRILLE DUCT DOWN DRG DUCT I RETURN GRILLE SRG SIDEWALL RETURN GRILLE VOLUME DAMPER DR DUCT MOUNTED REGISTER TRANSITION EG EXHAUST GRILLE AFF ABOVE FINISHED FLOOR MECHANICAL DETAILS Q NO SCALE 11 112 1 13 14 1 15 16 17 1 18 11 -NTIA 1 *1 CONSULTING ENGINEERS, LLC 5300 Paylor Lane Sarasota, FL 34240 TI 941-748-1319 Fax: 941-361-1221 www.me3-engr.com sidney@me3-engr.com Designed: BAK ME3 Job No: B17-1166 Checked: BAK Date: 09/29/2017 Drawn: KCC C.O.A.27552 Copyright 2017 ME3 All rights reserved P 9 N M L K J H G F REV. I DESCRIPTION I DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: "To the best of the Architect's or Engineer's knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by local authority in accordance with Chapter 553 and 663 of Florida Statutes." 9--CaL- D to/q f I � Kay C. Clem Florida License # 53270 WBR(IIIIIIIIIIIIIIINoI ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA BEALLS OUTLET #542 ZEPHYRH I LLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B MECHANICAL DETAILS SHEET TITLE WBRC CAD FILE PROJECT No. 3542XX GRAPHIC SCALE: 0„ ill SCALE: As Indicated 6mmmmil A PROJECT MANAGER: SHEET No. DRAWN BY: M 1 02 CHECKED BY: 19 20 1 I 2 1 3 1 4 1 5 I 6 I 7 I 8 I 9 1 10 1 11 1 12 1 13 4 Q 14 1 15 1 16 1 17 1 18 19 1 20 Q P 0 N M LI KI HI AREA NOT WORK OF BEALLS OUTLET TENANT G FI E D C B A EXISTING METER AND OVERHEAD SERVICE E' 'D' SERVICE, PANELS AND FEEDERS ARE EXISTING. SEE PANEL SCHEDULES FOR MODIFICATIONS TO PANELS. RELABEL EXISTING PANELS 'D' (FORMERLY -B-) 'E' (FORMERLY 'A-) EXISTING DISCONNECT, RECEPTACLE AND CIRCUITS AT RTU SHALL REMAIN EXISTING RTU ON ROOF EXISTING RTU ®N ON ROOF EXISTING DISCONNECT, RECEPTACLE AND CIRCUITS AT RTU SHALL REMAIN JUNCTION BOX W/ 4' PLUG MOLD 3/4" UP IN WALL TO CEILING SPACE ao M COMPUTER TABLE ELEVATION MANAGER / LP OFFICE NO SCALE JUNCTION BOX W/ 4' PLUG MOLD 3/4" UP IN WALL TO CEILING SPACE e Mm e MANAGER & LP DESKS ELEVATION (8)- MANAGER / LP OFFICE NO SCALE RECEPTACLE MOUNTED ON ® COLUMN 12" AFF Q EXISTING DISCONNECT, RECEPTACLE AND CIRCUITS AT RTU SHALL REMAIN EXISTING RTU ON ROOF RECEPTACLE MOUNTED ON COLUMN 12" AFF 2" EMT CONDUIT — SURFACE MOUNTED ON WALL CEILING 10'-0" AFF o io 4' X 4' X 3/4" SHEET OF PLYWOOD 1 (2) 2" EMT CONDUITS SURFACE MOUNTED ON WALL "v DATA RACK 4' PLUGMOLD 1,. WITH OUTLETS 6" ON -CENTER 30" m JUNCTION BOX W/ 3/4" C. UP IN WALL [TO CEILING SPACE SAFE BACKBOARD ELEVATION MANAGER / LP OFFICE NO SCALE 0 SECURITY ALARM 0 0 0 0 o KEYPAD ®FIRE ALARM ANNUNCIATOR PANEL 0oo LIGHTING CONTROL DIGITAL SWITCH FIRE ALARM PULL STATION (IF NOT AT DOOR) 4'-6" FLOOR FRONT ENTRY DEVICES ELEVATION NO SCALE 3/4" C. BUSHING FOR 120V CIRCUIT 4"X4" 2 1/8" 2 1/8" DEEP 1/4" RAISED DEEP BOX BOX DIVIDER COVER WITH RING CONDUIT RACO #231 RACO #707RAC RACO #777 SIDE VIEW IN WALLLL UUP P T TO CEILING SPACE 4X4 BOX W/ DIVIDER DETAIL INTERNAL DIVIDER SENTECH PTR #AKZ 950/3-5.08N 48" AFF -GREE� TERMINAL STRIP 4X4 BOX WITH DIVIDER FOR LINE VOLTAGE AND CONNECT CIRCUIT TO LOW VOLTAGE SECTIONS. TERMINAL STRIP. SEE ABOVE. LEAVE A MINIMUM 6" OF EAS CONTROLLER WIRE TO PLUG TERMINAL WILL BE MOUNTED STRIP INTO EAS CABINET OVER 4X4 OPENING EAS CONTROLLER DETAIL MOUNTED AT FRONT COUNTER NO SCALE ELECTRICAL LEGEND ® DUPLEX RECEPTACLE @ HEIGHT INDICATED TO CENTER ® DUPLEX RECEPTACLE WITH INTEGRAL SURGE SUPPRESION MOUNTED AS INDICATED SURGE ® QUAD RECEPTACLE @ HEIGHT INDICATED TO CENTER TELEPHONE OUTLET @ HEIGHT INDICATED TO CENTER v COMMUNICATION DATA/ VOICE OUTLET @ HEIGHT INDICATED TO CENTER m PLUGMOLD WITH RECEPTACLES 6" ON CENTER MOUNTED AS INDICATED ON THE PLANS. O JUNCTION BOX FOR CONNECTION OF DEVICE INDICATED. VERIFY MOUNTING WITH INSTALLATION REQUIREMENTS OF THE DEVICE. L0 DISCONNECT. REQUIREMENTS AS NOTED. GFI GFCI PROTECTED RECEPTACLE WP WEATHERPROOF ENCLOSURE FOR RECEPTACLE ETR EXISTING DEVICE TO REMAIN. RECONNECT TO NEW CIRCUIT IF INDICATED. RE EXISTING DEVICE TO BE RELOCATED TO LOCATION SHOWN. RECONNECT AS INDICATED. RRR EXISTING DEVICE TO BE REMOVED THEN REINSTALLED AND RECONNECTED. NOTES: 1. ELECTRICAL SERVICE, METERING, PANELS AND TRANSFORMER ARE EXISTING. 2. ALL EXISTING CIRCUIT BREAKERS NO LONGER NEEDED AT COMPLETION OF RENOVATION SHALL BECOME SPARES. TURN 'OFF' CIRCUIT BREAKER. 3. INSTALL NEW CIRCUIT DIRECTORIES AT PANELS REFLECTING ALL MODIFICATIONS TO THE CIRCUITS INCLUDING NEW CIRCUITS, EXISTING CIRCUITS REMAINING, CIRCUITS THAT HAVE BECOME SPARES, ETC. EXISTING METER \\` AND OVERHEAD SERVICE NEW LIGHTING CONTROL 20A, 2-POLE SWITCH PANEL, JB FOR POWER FOR W/H DISCONNECT. AND DATA OUTLET. MOUNT HIGH ON WALL SEE LIGHTING CONTROL ADJACENT TO W/H DIAGRAM. F-1 :�\rni E1__ F-1 0 EXISTING COMM BACKBOARD. ETR J J 'C' 'B' A W/H 24" REFRIG 12" SERVICE, PANELS AND FEEDERS SIMPLEX RECEPTACLE MOUNTE GFIlo FI A 9 A-15 ARE EXISTING. WITHIN CASING OF WATER COOLER GFI A-13 © TABLE B-27 AT ACCESSIBLE LOCATION. A-11 A-25,27 2' C 18 EXISTING BACKBOARD SEE PANEL SCHEDULES FOR A-15 A-13 C-24 RECEPTACLE TO MODIFICATIONS TO PANELS. COORDINATE EXACT MOUNTING. JAN o 24, O REMAIN. VERIFY LOUNGEC 2" CONDUIT FROM EXISTING DISCONNECT, EXISTING CIRCUIT. CONNECT REPLACEMENT FIRE JUNCTION BOX FOR RECEPTACLE AND ®� ALARM SYSTEM CABINETS TO RECESSED HAND DRYEREACH DUPLEX COMPUTER BKBD. UP TO J CEILING SPACE. CIRCUITS AT RTU SHALL EXISTING FIRE ALARM CIRCUIT VERIFY EXni OF QUAD ON SAFE REMAIN EXISTING SEPARATE 4' X 4' X 3/4" 88 C-8 (VERIFY CKT). AND MOUC-22 ADD DATA OUTLET IF NOT IN EACH RRTU ON PLYWOOD STOCK / -18 ROOF A 41IRCUIT _BACKBOARD. EXISTING RTU EXISTING. RECEIVING '`9`' SEE DETAIL. ON ROOF R.R. C-20UITS FROM 2BKBDDUP TO EXISTING DISCONNECT, CEILING SPACE. RECEPTACLE AND CIRCUITS AT RTU SHALL REMAIN RECEPTACLE MOUNTED ON COLUMN 12" AFF C-23/p� SALES AREA O EXISTING DISCONNECT, RECEPTACLE AND CIRCUITS AT RTU SHALL REMAIN RECEPTACLE MOUNTED IN B.O.S. L.P. SUPPLIED FRAME AT CEILING. VERIFY EXISTING RTU ON ROOF C-19 WITH B.O.S. REPRESENTATIVE FOR �J THE EXACT LOCATION OF CEILING FRAME. SURGE O NOTE: CONTRACTOR SHALL PROPERLY SUPPORT ALL NEW LOW VOLTAGE CABLING FROM THE BUILDING STRUCTURE (BLUEBOX CAT 5E, ETC.). PROVIDE J-HOOKS OR TRAY AT OPEN CEILING. NOTE: CONTRACTOR SHALL REMOVE ALL EXISTING OBSOLETE LOW VOLTAGE CABLING (PHONE, DATA, TV, ETC.). RECEPTACLE MOUNTED ON COLUMN 12" AFF C-21� C-13 NOTE: LIGHTING CONTROL DIGITAL C-15 INSTALL CONDUIT FOR EAS SWITCH, FIRE ALARM PEDESTALS. SEE EAS SYSTEM PLAN ANNUNCIATOR, SECURITY AND DETAILS, ARCHITECTURAL FOR KEYPAD AND PULL STATION. ENLARGED PLAN AND DETAILS SEE DETAIL, THIS SHEET. rC-17 12" 12" J C-27 J.B. FOR POWER TO AUTOMATIC DOORS. COORDINATE WITH DOOR INSTALLER. TYPICAL 2 DOORS. EXISTING DISCONNECT, RECEPTACLE AND CIRCUITS AT RTU SHALL REMAIN EXISTING RTU ON ROOF POLE POWER POLE T 4X4 DIVIDED BOX FOR EAS SYSTEM SEE DETAIL, THIS SHEET O RECEPTACLE MOUNTED ON COLUMN 12" AFF C-21 O RECEPTACLE MOUNTED ON COLUMN 12" AFF C-21® O EXISTING RTU ON ROOF EXISTING DISCONNECT, RECEPTACLE AND CIRCUITS AT RTU SHALL REMAIN C-19 e� L J�RECEPTACLE MOUNTED IN B.O.S. L.P. SURGE SUPPLIED FRAME AT CEILING. VERIFY WITH B.O.S. REPRESENTATIVE FOR P 0 N M L K J H G ME3 CONSULTING ENGINEERS, LLC 5300 Paylor Lane Sarasota, FL 34240 Tel: 941-748-1319 Fax: 941-361-1221 www.me3-engr.com sidney@me3-engr.com Designed: BAK ME3 Job No: B17-1166 Checked: BAK Date: 09/29/2017 F Drawn: BPZ C.O.A.27552 Copyright 2017 ME3 All rights reserved REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: "To the best of the Architect's or Engineer's knowledge, the plans D and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by local authority in €t accordance with Chapter 553 and t 663 of Florida Statutes." Bryan P. Zapf Florida License # 46141 THE EXACT LOCATION OF CEILING WBRCIENC FRAME. ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 NOTE: Suite 210 Fax: 941-556-0759 INSTALL CONDUIT FOR EAS Lakewood Ranch, FL 34202 www.wbrcae.com PEDESTALS. SEE EAS SYSTEM PLAN Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA AND DETAILS, ARCHITECTURAL FOR B EALLS OUTLET #542 ENLARGED PLAN AND DETAILS 12" C-17 ZEPHYRHILLS 12" 6030 Gall Blvd, Zephyrhills, FL 33542 B C-25 J ELECTRICAL PLAN J.B. FOR POWER TO AUTOMATIC DOORS. COORDINATE WITH DOOR INSTALLER. TYPICAL 2 DOORS. SHEET TITLE: WBRC CAD FILE: PROJECT No. 3542XX GRAPHIC SCALE: Q„ 1 �� SCALE: As Indicated L 1 A ELECTRICAL PLAN PROJECT MANAGER: SHEET No. N DRAWN BY E 1 0 1 I V I CHECKED BY: 17 18 19 20 1 1 2 1 3 Q 4 1 5 I 6 1 7 i 8 I 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 1 17 SUPPORT CLIP FIXTURE FROM STRUCTURE. #12 AWG WIRES MINIMUM. SUPPORT FIXTURE PER NEC ARTICLE 410 A MINIMUM OF TWO CLIPS AND ANY LOCAL SEISMIC REQUIREMENTS. SHALL BE LOCATED AT EACH FIXTURE 18 19 1 20 9 P 0 N M L K J H G F E 0 C B V B-LINE #BA-1 SUPPORT CLIP OR EQUAL T-GRID DWI (INLCUDECUDED SUPPORT CUP BOLT WITH CLIP) THROUGH TOP OF FIXTURE AND SECURED BY WINGNUT WALLWASH FIXTURE FIXTURE BODY WEIGHT IS LESS THAN 10 LBS (7.7LBS). WALLWASH FIXTURE SUPPORT DETAIL NO SCALE NORMAL BALLAST UNIT EQUIPMENT CONNECTED IN SIMILAR MANNER EMERGENCY BALLAST SWITCH IN EMERGENCY BALLAST MUST ROOM OR BE CONNECTED TO THE SAME LIGHTING CIRCUIT AS THE NORMAL RELAY BALLAST. THIS DETAIL DOES NOT APPLY TO FIXTURES WITH EMERGENCY BALLASTS IN THE SALES AREA WHICH ARE ON AN UNCONTROLLED CIRCUIT. CONNECT EMERGENCY BALLASTS TO THE SAME N H CIRCUIT AS THE FIXTURE. SWITCHED EMERGENCY FIXTURE SCHEMATIC NOT TO SCALE SUPPORT FROM FIXTURE BODY TO STRUCTURE - 2 TIE WIRES PER FIXTURE AT OPPOSITE CORNERS WITH 4 TWISTS PER WIRE. #12 AWG WIRES MINIMUM. SUPPORT FIXTURE PER NEC ARTICLE 410 AND ANY LOCAL SEISMIC REQUIREMENTS.. / STRUCTURE ABOVE VERIFY HEIGHT NOTE: FIXTURE SUPPORT WIRES ANCHORED TO STRUCTURE OR UNITSTRUT FRAMING ANCHORED TO STRUCTURE. LAY -IN CEILING LAY -IN FIXTURE SUPPORTED INDEPENDENTLY OF LAY -IN CEILING FIXTURE TO STRUCTURE LAY -IN CEILING RECESSED FIXTURE SUPPORT DETAIL NO SCALE LIGHTING LEGEND 1771 Z X 4' 4-LAMP LENSED TROFFER WITH (4) T8 LAMPS. E. SAM JONES ITEM # 2GT8432Al2MVOS1O LP NEW FIXTURES FIXTURES ®2' X 4' 4-LAMP LENSED TROFFER WITH (4) T8 LAMPS, EMERGENCY EGRESS LIGHTING BATTERY PACK, CONNECT TO EMERGENCY LIGHTING CIRCUIT OR LIGHTING CIRCUIT AHEAD OF ANY SWITCHING. E. SAM JONES ITEM # 2GT8332Al2MV1/3EL14 LP NEW FIXTURES 4' 1-LAMP ASYMMETRICAL STRIP FIXTURE WITH (1) T8 LAMP, MULTIVOLT BALLAST. O E. SAM JONES ITEM # Z132MVOLTGEUM WITH Z8ASR48 J4 REFLECTOR NEW FIXTURES 4' 2-LAMP INDUSTRIAL FIXTURE. ® E. SAM JONES ITEM # LA232MVOLT1/4GEUM NEW FIXTURES 8' 2-LAMP INDUSTRIAL FIXTURE. E. SAM JONES ITEM # TLA232MVOLT1/4GEUM NEW FIXTURES EXIT SIGN. WALL OR CEILING MOUNTED. CONNECT TO EMERGENCY LIGHTING CIRCUIT OR LIGHTING e ® CIRCUIT AHEAD OF SWITCHING OR CONTROL. E. SAM JONES ITEM # EXR LED EL M6 (NEW) NEW FIXTURES FIXTURES 4& EMERGENCY EGRESS LIGHTING UNIT. WALL MOUNTED (T-6"). CONNECT TO LIGHTING CIRCUIT AHEAD OF SWITCHING OR CONTROL. E. SAM JONES ITEM # EU2 LED M12 NEW FIXTURES EXIT SIGN / EMERGENCY EGRESS LIGHTING COMBO UNIT. WALL OR CEILING MOUNTED. CONNECT TO LIGHTING CIRCUIT AHEAD OF SWITCHING OR CONTROL. `�g j' E. SAM JONES ITEM # LHQM SW3R N NEW FIXTURES NEMA EXTERIOR NEMA 4X EMERGENCY EGRESS LIGHTING UNIT. WALL MOUNTED 9'-01, AFF. CONNECT TO 4X ® EMERGENCY LIGHTING CIRCUIT OR LIGHTING CIRCUIT AHEAD OF SWITCHING OR CONTROL. SEAL CONDUIT PENETRATION THROUGH WALL. E. SAM JONES ITEM # INDX618 NEW FIXTURES MOTION DETECTOR SWITCH, RECESS MOUNT 48" AFF. SENSOR SWITCH MODEL WSD-PDT. NEW SWITCHES REPLACE EXISTING SWITCHES WHERE INDICATED. 20A, 1-POLE DECORA SWITCH, RECESS MOUNT 48" AFF. EF EXHAUST FAN (BY MECH. CONTR.). SWITCHED WITH LIGHTS. SET OCCUPANCY SENSOR TO RUN 10 MINUTES AFTER NO OCCUPANCY IS DETECTED. RELAY FOR EXHAUST FAN. 120V EXHAUST FAN CIRCUIT SHALL BE ROUTED VIA RELAY THEN TO EXHAUST ® FAN. 277V LIGHTING CIRCUIT SWITCHED BY ROOM OCCUPANCY SENSOR SHALL CONTROL RELAY. ETR EXISTING DEVICE OR FIXTURE TO REMAIN. RECONNECT AS INDICATED. REP REPLACE EXISTING DEVICE. NOTES: 1 • NEW LIGHTING FIXTURES SHALL BE SUPPLIED BY B.O.S., INSTALLED BY CONTRACTOR. CONTACT IS LYN GREATREX OF E. SAM JONES CO., PHONE 1-888-851-1955, EMAIL Igreatrex@esamjones.com 2. INSTALL NEW LIGHTING CONTROLS, SEE LIGHTING CONTROL DIAGRAM. REROUTE EXISTING LIGHTING CIRCUITS (INTERCEPT AND EXTEND) VIA LIGHTING CONTROL PANEL RELAYS AS NOTED. REMOVE ALL EXISTING LIGHTING CONTROLS, TIMECLOCKS, CONTACTORS, ETC. 3. CONNECT BATTERY PACKS OF EMERGENCY LIGHTING FIXTURES (2X4, EXIT SIGNS AND UNIT EMERGENCY LIGHTING) TO EMERGENCY LIGHTING CIRCUITS OR LIGHTING CIRCUIT AHEAD OF SWITCHING, RELAY OR CONTROLS. / V \\ // Y\\ I/ I CONNECT BATTERY PACK OF FLUORESCENT FIXTURES OR NEW LIGHTING EMERGENCY UNIT EQUIP. TO THE LINE CONTROL PANELS. SIDE OF THE LIGHTING CIRCUIT SERVING NEMA 4X SEE LIGHTING REMOVE EXISTING B-29 AHEAD TIN COMPUTER,, LAD OF ANYSWITCHING, 9, 0„ CONTROL DIAGRAM. LIGHTING CONTACTORS OF CONTRO RESTROOMS. A-3 A.F.F. AND TIMECLOCK NEMA 4X 9'-0" A.F.F. LIGHTING CONTROL DIGITAL AD 'C' 'B' 'A' JAN A-3 SWITCH. MOUNT ADJACENT OF CONTROL B 1 O NG CO VIPLITE B-12 B 12 TO BKBD. 48" AFF EF . . B-29 B-29 - B-29 . . m A-3 3-10 B-9 A-3 B-7 B-8 A-3 B-6 m ._ . STOCK / FIXTURES A L lo . RECEIVING CHAIN HUNG 12'-0" AFF A-1 _ B-29 AHEAD B-29 B-29 B-29 OF CONTROL B-9 B-10 B-9 B-8 B-7 B-8 B-7 B-6 EF EF A-1 B-29 AHEAD B-29 AHEAD R R. A-1 R OF CONTROL OF CONTROL 1 1H H H I N L i I I I m I I I� I 1 177 17 1®1 B 12 B-12 v m �A-3� -10 B-9 A-3 B-7 B-8 A-3 B-6 B-5 A-3 B-5 13-4 A-1 I B-4 B-3 I I I A-1 I I I I B-1 I B-2 A-1 I Al I AI I I III IAl I Al I I. AREA NOT WORK in I OF BEALLS OUTLET TENANT O O O A-1 A-3 B-9 -10 B-9 B-8 B-7 B-8 B-7 B-6 B-5 B-6 B-5 B-4 B-3 I B-4 B-3 B-2 B-1 B-2 B-1 I_] in — A-3 B-9 B-10 B-9 B-8 B-7 B-8 B-7 B-6 B-5 B-6 B-5 B-4 B-3 B-4 B-3 B-2 B-1 I B-2 I B-1 IH 11--i _H 111 11 1 11 H 11 11 1-1 I . I . I I I in II A-3 -10 I B-9 A-3 I B-7 B-8 A-3 B-6 B-5 A-3 B-5 B-4 A-1 B-4 B-3 A-1 B-1 B-2 A-1 - - V - - Ai I I Al I 1 —1 1 1 1 1A I I i I I I I I i - [A I I A] in i B-9 -10 B-9 B-8 B-7 B-8 B-7 B-6 B-5 B-6 B-5 B-4 B-3 B-4 B-3 B-2 O B-1 B-2 B-1 A 3® I L i --i in O S LES R A e B-9 -10 B-9 I B-8 I B-7 B-8 B-7 B-6 B-5 B-6 I B-5 B-4 I B-3 B-4 B-3 B-2 B-1 B-2 B-1 I L A-3 -10 B-9 I A-3 I B-7 B-8 A-3 B-6 I B-5 A-1 B-5 B-4 A-1 B-4 I B-3 A-1 B-1 B-2 A-1 _ . H H I IN _ I I A] in LI HTI G ON ROL DIG TAL S ITC . S E F ON D IC J.B. S F R L DDIISCIONWA L. C O DIN TE C° EL VA ION AND LIG HTIN G LO ATI N AND GONPIECI ION ROIJTE IA NEW 7 m CONTROL IAG AM LIG TINGCONTROL AN L, CONTROLZO E'B' 00 .16— J166— J6— J6— J6— J6.— J6— J6.— J6— —.16-7— J6— J6— J6.— J6.— J6.— B16 B- 16 A-1 B14 B14 A- B14 614 B-3 A-1 A-1 � B- 14 B- 14 , i _ r A JUNCTION BOX FOR POWER TO BUILDING SIGNAGE. INSTALL NEW CIRCUIT. CONTRACTOR SHALL CONNECT ALL WHIPS TO B-28\ }� SIGNAGE DRIVERS / TRANSFORMERS. COORDINATE v MOUNTING OF BOXES AND ROUTING OF WHIPS. ROUTE CIRCUIT VIA THE NEW LIGHTING CONTROL PANEL, CONTROL ZONE 'C'. 1 2 1 3 1 4 1 5 1 6 1 7 1 8 9 10 11 12 1 13 14 15 16 LIGHTING PLAN N 1/8" = 1'-0" 17 18 ME3 CONSULTING ENGINEERS, LLC 5300 Paylor Lane Sarasota, FL 34240 Tel: 941-748-1319 Fax: 941-361-1221 www.me3-engr.com sidney@me3-engr.com Designed: BAK ME3 Job No: B17-1166 Checked: BAK Date: 09/29/2017 Drawn: BPZ C.O.A.27552 Copyright 2017 ME3 All rights reserved P C N M L K J H G F REV. I DESCRIPTION I DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: "To the best of the Architect's or Engineer's knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by local authority in accordance with Chapter 553 and 663 of Florida Statutes." D Bryan P. Zapf Florida License # 46141 WBRCIIIIIIIIIIIIIIINoI. ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Finn Lic. # AA26001395 & 27389 Douglas WA"itney AIA BEALLS OUTLET #542 ZE P HYRH I LLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B LIGHTING PLAN SHEET TITLE WBRC CAD FILE PROJECT No. 3542XX GRAPHIC SCALE: ou ,� SCALE: As Indicated L I A PROJECT MANAGER: SHEET No. DRAWN BY: - E 1 02 CHECKED BY: 19 20 Q 1 I 2 1 3 1 4 I 5 1 6 1 7 I 8 1 9 1 10 1 11 1 12 1 13 1 14 I 15 1 16 1 17 1 18 19 1 20 Q P 0 N M LI KI J HI G FI E D C B A ELECTRICAL PROJECT REQUIREMENTS THE CONTRACTOR SHALL ARRANGE AND PAY FOR ALL WIRE SHALL BE SINGLE CONDUCTOR COPPER WITH 600 PERMITS AND INSPECTIONS REQUIRED IN THIS WORK. VOLT INSULATION. #10 AND SMALLER SHALL BE SOLID. #8 AND LARGER SHALL BE STRANDED. MINIMUM WIRE ALL WORK SHALL BE DONE IN ACCORDANCE WITH SIZE SHALL BE ALL WIRE AND CABLE SHALL BE NEW THESE PLANS, SPECIFICATIONS, LOCAL, STATE AND BR AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN NATIONAL CODES. CERTIFICATES OF INSPECTION, PACKAGES. ALL WIRING OF ANY TYPE SHALL BE IN WHERE REQUIRED, SHALL BE OBTAINED AND PAID FOR CONDUIT. GENERAL WIRING SHALL BE THW OR THEN. BY THIS CONTRACTOR AND FURNISHED TO THE TENANT. (ALUMINUM CONDUCTORS SHALL NOT BE PERMITTED). THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL MC CABLE MAY BE USED FISHED IN WALLS OR NOT TO LABOR, MATERIALS, EQUIPMENT AND TOOLS TO EXCEED T-0" IN LENGTH AS FINAL CONNECTION TO PERFORM ELECTRICAL WORK AS SHOWN, NOTED OR EQUIPMENT OR FIXTURES. SCHEDULED FOR A COMPLETE INSTALLATION. RECEPTACLES SHALL BE 20A-125V 3-WIRE GROUNDING ALL MATERIALS AND EQUIPMENT SHALL BE COMMERCIAL TYPE EQUAL TO HUBBEL 5362. GRADE AND SHALL CARRY AN UNDERWRITERS ALL MOUNTING HEIGHTS SHOWN ON THE DRAWINGS LABORATORIES (U.L.) LABEL. SHALL BE MEASURED FROM FINISHED FLOOR TO TOP THE CONTRACT DRAWINGS INDICATE THE EXTENT AND OF BOX. ELECTRICAL CONTRACTOR SHALL VERIFY GENERAL ARRANGEMENTS OF EQUIPMENT AND WITH THE ARCHITECTURAL DRAWINGS, COUNTER TOP SYSTEMS. IF ANY DEPARTURES FROM THE CONTRACT AND CABINET HEIGHTS, TO AVOID CONFLICTS WITH DRAWINGS ARE DEEMED NECESSARY BY THE BACKSPLASHES, ETC. CONTRACTOR, DETAILS OF SUCH DEPARTURES AND OUTLET BOXES SHALL BE GALVANIZED STEEL, ONE REASONS THEREFORE SHALL BE SUBMITTED TO THE PIECE, PRESSED STEEL WITH SMOOTH PLASTIC COVER OWNER FOR APPROVAL. PLATE. VERIFY COLOR OF THE DEVICE AND IT IS THE INTENT OF THE PLANS AND SPECIFICATIONS COVERPLATE.. TO PROVIDE A COMPLETE AND OPERATING JUNCTION BOXES AND COVERS SHALL BE GALVANIZED INSTALLATION INCLUDING ALL OBVIOUSLY NECESSARY STEEL, CODE GAUGE SIZE. ITEMS EVEN THOUGH SOME ITEMS MAY NOT BE IT IS THE RESPONSIBILITY OF THE ELECTRICAL INDICATED ON THE DRAWING OR SPECIFICATIONS. CONTRACTOR TO PROPERLY BALANCE THE LOAD OF ALL ALL OBVIOUS ERRORS AND/OR OMISSIONS IN THE BRANCH CIRCUITS BETWEEN THE PHASES OF THE ABOVE MENTIONED DOCUMENTS SHALL BE CALLED TO SYSTEM, REGARDLESS OF THE CIRCUITING INDICATED. THE ATTENTION OF THE ARCHITECT PRIOR TO CONSTRUCTION. THE ELECTRICAL SERVICE, METERING, DISTRIBUTION, FEEDERS, TRANSFORMERS AND PANELS ARE EXISTING. THIS CONTRACTOR SHALL INSPECT THE JOB SITE MODIFY CIRCUIT BREAKERS AS INDICATED ON THE PANEL WHERE THE WORK IS TO BE PERFORMED AND SHALL SCHEDULES. AQUAINT HIMSELF WITH THE CONDITIONS UNDER WHICH IT SHALL BE EXECUTED. THIS CONTRACTOR SHALL FURNISH AND INSTALL AND CONDUIT SHALL BE STANDARD ELECTRIC METALLIC MAKE OPERATIVE ALL ELECTRICAL WORK. ALL TUBING (EMT) ACCORDING TO CODE REQUIREMENTS. INCIDENTAL ITEMS NOT FULLY DESCRIBED, BUT CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, NECESSARY FOR THE COMPLETE INSTALLATION ARE EXCEPT AS OTHERWISE APPROVED. EMT TO BE FURNISHED. CONNECTIONS SHALL BE COMPRESSION TYPE. EMT ELECTRICAL CONTRACTOR SHALL GUARANTEE THAT THE SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS COMPLETE ELECTRICAL SYSTEMS INSTALLED UNDER RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN THIS CONTRACT SHALL BE FREE OF DEFECTS IN INTERIOR PARTITIONS. EMT SHALL NOT BE USED BELOW WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE GRADE OR IN POURED CONCRETE SLABS OR WALLS, (1) YEAR. IF DEFECTS OCCUR DURING THIS ONE (1) YEAR PVC CONDUIT SHALL BE USED AT THESE LOCATIONS. GUARANTEE PERIOD, EXCLUSIVE OF LAMP BURNOUT, FLEXIBLE METAL CONDUIT IS TO BE USED ONLY FOR ELECTRICAL CONTRACTOR SHALL REPAIR OF REPLACE CONNECTIONS TO DEVICES AND NOT FOR HOMERUNS. THE DEFECTIVE ITEMS AT EXPENSES THE VERIFY WITH THE LOCAL JURISDICTION FOR TENANT, AND TO THE SATISFACTION OF THE TENANT. SUITABILITY OF USE IN RETAIL STRUCTURES. FIRE SEAL ALL PENETRATIONS OF RATED WALLS, FLOORS, ETC. USING UL FIRE STOP SYSTEM. FIELD SLEEVES SHALL EXTEND AT LEAST 2" ABOVE FINISHED VERIFY ALL RATED ASSEMBLIES AFFECTED BY WORK FLOOR AND ALL SLEEVES THROUGH FIRE RATED WALLS AND PROVIDE FIRE STOP SYSTEM RATED FOR THAT USE. AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. ELECTRICAL SERVICE CALCULATION PANELS 'A'. 'B', 'C' CONNECTED DEMAND RECEPTACLE LOAD 7,920 7,920 LIGHTING >3 HR. LOAD 21,050 26,312 OTHER LOADS 7,630 7,630 RTU EQUIPMENT 91,146 91,146 SIGNAGE 1,690 2,112 TOTAL 129,436 135,120 375.1A DEMAND 400A SERVICE @ 208V, 3-PHASE EXISTING ELECTRICAL SERVICE CALCULATION PANELS 'D', 'E' CONNECTED DEMAND RTU EQUIPMENT 48,990 48,990 TOTAL 48,990 48,990 135.9A DEMAND 400A SERVICE @ 208V, 3-PHASE EXISTING (2) BUTTON DIGITAL SWITCH (1) BUTTON DIGITAL SWITCH BLUE BOX CHELSEA BLUE BOX CHELSEA BY ELECTRICAL BY MODEL # CH-2. MODEL # CH-1. CONTRACTOR CONTRACTOR SECURITY CO ALL SALES LIGHTING - ON. SIGN & CANOPY/PARKING- ON/OFF SIGN & CANOPY/PARKING- ON/OFF MOUNT AT MGR / LP OFFICE 48" AFF. RELAY PROVIDED MOUNT AT FRONT OF STORE, AND INSTALLED SEE PLAN AND DETAIL. BY CONTRACTOR. �� MOUNT IN J.B. I r--� I " SWITCH LABEL SALES O ON SIGN B ON/OFF O DIGITAL SWITCH BUTTONS SHALL BE FACTORY LABELED AS SHOWN. SWITCH SWITCH lull LABEL LABEL lul RJ45 RJ45 RJ45 CAT 5 E CABLE I BLUE BOX D6 OPTION CAT 5E ANALOG CABLE INPUTS LC&D BLUE BOX O GR1416LTC (00 RJ45 MASTER � O CONTROL PANEL 0-0 O CAT 5 E ASTRO — CABLE CLOCK 24V RJ45 NCL RELAYS N.O. R DC 18 GA WIRE 24V NSTALL POWER SUPPLY INSTALL 18 GA WIRE FROM DEC 7EPUffUI PITY PANEL 120V RELAY TO SECURITY PANEL. AC INPUT 12V DC OUTPUT LEAVE 5' OF WIRE COILED 12pV 200 mA AT SECURITY PANEL FOR AC CONNECTION BY SECURITY INSTALLER LC&D BLUE BOX SALES AREA GR2400 ETHERNET WORK LTG INTERFACE CABINET LTG CONTROL RJ45 ZONE A STOCK LTG RJ45 RJ45 SALES LTG DATA OUTLET MOUNTED NEAR CONTROL LIGHTING ZONE B CONTROL PANEL. WALLWASH LTG. LED DISKS CAT 5E PATCH CORD (BY B.O.S.) SPARE RELAYS CAT 5E CABLE LC&D BLUE BOX ZONE TIME PROGRAMMING GR 1404 LTC ZONE 'A' - WORK LIGHTING RJ45 REMOTE CONTROL PANEL ON - PRESET TIME 7:30 AM ON - FRONT OF STORE DIGITAL BUTTON ON -SECURITY SYSTEM INPUT OFF - PRESET TIME 9:45 PM NCL RELAYS ZONE 'B' - SALES LIGHTING SIGN - FRONT CONTROL ON - PRESET TIME 9:00 AM ZONE C ON - FRONT OF STORE DIGITAL BUTTON ON -SECURITY SYSTEM INPUT N SPARE OFF - PRESET TIME 9:15 PM N RELAYS ZONE 'C' - SIGNAGE ON - 30 MINUTES PRIOR TO SUNSET ON -FRONT AND REAR STORE DIGITAL BUTTON LIGHTING CONTROL SYSTEM SUPPLY ! INSTALL MATRIX OFF - PRESET TIME 10:00 PM OFF - FRONT AND REAR STORE DIGITAL BUTTON LIGHTING CONTROL ITEM SUPPLIED INSTALL ZONE 'D' - FRONT CANOPY / FACADE / PARKING LTG CONTROL PANELS) B.O.S. G.C. ON -30 MINUTES PRIOR TO SUNSET DIGITAL SWITCHES B.O.S. G.C. ON -FRONT AND REAR STORE DIGITAL BUTTON GR2400 COMMUNICATIONS INTERFACE FOR ETHERNET B.O.S. G.C. OFF - PRESET TIME 10:00 PM OFF - FRONT AND REAR STORE DIGITAL BUTTON CAT 5E CABLE / RJ45 JACKS (BETWEEN SYSTEM DEVICES) G.C. G.C. ZONE'E' - REAR EXTERIOR LIGHTING RELAY FOR SECURITY INTERFACE(24V N.O./12 V CONTROL) G.C. G.C. ON -30 MINUTES PRIOR TO SUNSET OFF - SUNRISE CAT 5E CABLE FOR LIGHTING SYSTEM IS UNRELATED TO OTHER CAT 5E CABLE SUPPLIED BY B.O.S. FOR DATA SYSTEMS. COLOR OF CABLE SHALL BE PURPLE. LIGHTING CONTROL DIAGRAM NO SCALE LIGHTING CONTROL NOTES DESCRIPTION: PANEL(S) AND SWITCHES SHALL BE PROVIDED, INSTALLED, CONNECTED AND PROGRAMMED BY THE ELECTRICAL CONTRACTOR. CONTACT PERSON FOR LC&D BLUE BOX EQUIPMENT IS SCOTT LIEFFERS WITH ENVISION LIGHTING SYSTEMS, TELEPHONE 727.576.8488. LIGHTING CONTROL MASTER PANEL SHALL BE LIGHTING CONTROL AND DESIGN, INC. (LC&D) BLUE BOX MODEL GR1416-LT-INT WITH FOLLOWING OPTIONS: 1. "NCL" NORMALLY CLOSED LATCHING RELAYS FOR EACH CIRCUIT CONTROLLED AND SPARES (16 TOTAL) 2. "DTC" DIGITAL TIMECLOCK 3. "DV" TRANSFORMER 4. "D6" 6 INPUTS WITH ENABLE/DISABLE FOR ANALOG INPUT. 5. NEMA 1 SURFACE MOUNT CABINET GR1416-LT-ENC. LIGHTING CONTROL PANEL SHALL HAVE 16 RELAY CAPACITY, ASTRONOMIC CLOCK, NON-VOLATILE MEMORY WITH BATTERY BACKUP (10 YEAR BATTERY). RELAYS SHALL BE NORMALLY CLOSED (BLUE BOX NCL RELAY). FILL PANEL WITH RELAYS, DO NOT LEAVE ANY SPACES. IF THERE ARE GREATER THAN 16 CONTROLLED CIRCUITS A REMOTE RELAY PANEL SHALL BE USED FOR THE ADDITIONAL CIRCUITS. PANEL SHALL BE THE SAME AS THE MASTER PANEL BUT WITHOUT TIMECLOCK AND OF 4 / 8 / 16 RELAY CAPACITY LINKED TO MASTER PANEL WITH CAT 5E CABLE. BLUEBOX INTERFACE CABINET GR2400-L2-PCETH-DV-5M-NE1 SHALL BE INSTALLED TO PROVIDE COMMUNICATIONS INTERFACE TO ETHERNET. DIGITAL SWITCHES SHALL BE LC&D CHELSEA SERIES WITH 1 BUTTON MODEL # CH-1 OR 2 BUTTONS MODEL # CH-2, LINKED TO MASTER PANEL WITH CAT 5E CABLE. LABEL BUTTONS AS INDICATED. COLOR OF SWITCHES AND BUTTONS SHALL BE WHITE. PROGRAMMING: SEE LIGHTING CONTROL SCHEDULE FOR SPECIFIC ZONE INFORMATION. 1. (ZONE 'A'): WORK LIGHTING SHALL TURN ON/OFF BY PRESET TIME, DIGITAL SWITCH INPUT AND UPON INPUT FROM THE SECURITY PANEL. WORK LIGHTING IS 50% OF TROFFER SALES LIGHTING, STOCK ROOM LIGHTING, RESTROOMS, AND THE RESTROOM EXHAUST FAN. 2. (ZONE 'B'): SALES LIGHTING SHALL TURN ON/OFF BY PRESET TIME, DIGITAL SWITCH INPUT AND UPON INPUT FROM THE SECURITY PANEL. SALES LIGHTING IS REMAINING TROFFERS IN SALES AREA AND WALL WASH FIXTURES. 3. (ZONE'C'): SIGNAGE SHALL TURN ON BY ASTRONOMIC CLOCK 30 MINUTES PRIOR TO SUNSET OR DIGITAL SWITCH INPUT AND TURN OFF AT PRESET DAILY TIMES OR DIGITAL SWITCH INPUT. (ZONES 'C' AND 'E' CONTROLLED TOGETHER) 4. (ZONE'D'): FRONT EXTERIOR CANOPY / FACADE / PARKING LOT LIGHTING SHALL TURN ON BY ASTRONOMIC CLOCK 30 MINUTES PRIOR TO SUNSET OR DIGITAL SWITCH INPUT AND TURN OFF AT PRESET DAILY TIMES OR DIGITAL SWITCH INPUT. (ZONES 'C' AND'D' CONTROLLED TOGETHER) 5. (ZONE'E'): REAR / SIDES EXTERIOR LIGHTING SHALL TURN ON BY ASTRONOMIC CLOCK 30 MINUTES PRIOR TO SUNSET AND TURN OFF AT SUNRISE. 6. INTERIOR LIGHTING SHALL TURN OFF BY DAILY SWEEP WITH WARNING BLINKS. SWEEP SHALL OCCUR AT TIME SPECIFIED BY BEALLS REPRESENTATIVE. 7. ASTRONOMIC CLOCK SHALL BE SET FOR THE LATITUDE OF THE STORE LOCATION. PANELBOARD DESIGNATION: E RENAME PANEL TO'E' FROM'A' VOLTAGE: 208/120V 3PH-4W MAINS RATING: 200 AMPS MAIN CB TRIP RATING: 200 AMPS ■ SURFACE FLUSH ■ MCB MLO INTERRUPTING RATING: 22,000 AIC ENCLOSURE: NEMA 1 SERVES CB SIZE LOAD VA CKT# CKT# LOAD VA CB SIZE SERVES RTU 2 60/ 3 6244 1 2 7 20 SPARE 2 6244 3 4 7 20 SPARE 6244 5 6 7 20 SPARE RTU 35/ 3 3842 7 8 7 20 1 SPARE 3842 9 10 7 20 SPARE 2 3842 11 12 20 SPARE SPARE 7 20 13 14 7 20 SPARE SPARE 7 20 15 16 20 SPARE SPARE 7 20 17 18 7 20 SPARE SPARE 20 19 20 7 20 SPARE SPARE 7 20 21 22 7 20 SPARE SPARE 7 20 23 24 7 20 SPARE SPARE 7 20 25 26 7 20 SPARE SPARE 7 20 27 28 7 20/ 2 SPARE 29 30 7 31 32 33 34 35 1 36 37 38 39 40 41 42 A B C DEMAND: 30.3 KW 83.9A PANELBOARD DESIGNATION: D RENAME PANELTO'D'FROM'B' VOLTAGE: 208/120V 3PH-4W MAINS RATING: 200 AMPS MAIN CB TRIP RATING: 200 AMPS ■ SURFACE FLUSH ■ MCB MLO INTERRUPTING RATING: 22,000 AIC ENCLOSURE: NEMA 1 SERVES CB SIZE LOAD VA CKT# CKT# LOAD VA CB SIZE SERVES RTU 2 60/ 3 6244 1 1 2 7 20 SPARE 2 6244 3 4 7 20 SPARE 2 6244 5 6 7 20 SPARE SPARE 7 20 7 8 7 20 SPARE SPARE 7 20 9 10 7 20 SPARE SPARE 7 20 11 12 7 20 SPARE SPARE 7 20 13 14 7 20 SPARE SPARE 7 20 15 16 7 20 SPARE SPARE 7 20 17 18 7 20 SPARE SPARE 7 20 19 20 7 20 SPARE SPARE 7 20 21 22 7 20 SPARE SPARE 7 20 23 24 7 20 SPARE SPARE 7 20 25 26 7 20 SPARE SPARE 7 20 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 A B C DEMAND: 18.7 KW 51.9A PANEL AND CIRCUIT BREAKER NOTED ITEMS 01 EXISTING CIRCUIT BREAKER USED FOR NEW CIRCUIT. © EXISTING CIRCUIT TO REMAIN. Q3 EXISTING CIRCUIT TO REMAIN. MODIFY OR RELOCATE AS INDICATED ON THE DRAWINGS. ® ROUTE NEW CIRCUIT VIA NEW LIGHTING CONTROL PANEL. Q5 ROUTE EXISTING CIRCUIT VIA NEW LIGHTING CONTROL PANEL. ® NEW CIRCUIT BREAKER AT EXISTING SPACE FOR NEW CIRCUIT. O EXISTING CIRCUIT IS / WILL BECOME A SPARE. VERIFY CIRCUIT WILL NO LONGER BE USED OR NEEDED AT COMPLETION OF RENOVATION ® REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKER INDICATED. 09 RECONNECT EXISTING DEVICE TO NEW CIRCUIT. DEVICE WAS FED FROM REMOVED PANEL. (LOCK) INDICATES TO INSTALL HANDLE LOCK CIRCUIT USAGE NOTE: CIRCUIT USAGE IS DERIVED FROM PANEL SCHEDULES. VERIFY EXACT ACTUAL ARRANGEMENT OF CIRCUITS AT EXISTING PANELS INSTALLED AS WORK OF THE SHELL BUILDING (NOT IN THIS PERMIT). IF NEW CIRCUIT IS SHOWN AT A CIRCUIT BREAKER WHERE AN EXISTING CIRCUIT MUST REMAIN, RELOCATE NEW CIRCUIT TO A SPARE OR NEW CIRCUIT BREAKER ON THE SAME PANEL. COORDINATE PHASING OF CIRCUITS OLD AND NEW SO STORE OPERATIONS ARE NOT DISRUPTED. WEATHER HEADS EXISTING 200A FEED EXISTING 200A FEED PANELBOARD DESIGNATION: A VOLTAGE: 208/120V 3PH-4W MAINS RATING: 400 AMPS MAIN CB TRIP RATING: 400 AMPS ■ SURFACE FLUSH ■ MCB MLO INTERRUPTING RATING: 35,000 AIC ENCLOSURE: NEMA 1 SERVES CB SIZE LOAD VA CKT# CKT# LOAD VA CB SIZE SERVES LTG-EMERG / NITE (LOCK) 3 20 1411 1 2 7 20 SPARE LTG-EMERG / NITE (LOCK) 3 20 1411 3 4 7 20 SPARE SPARE 7 20 5 6 20 SPARE SPARE 7 20 7 8 7 20 SPARE REFRIGERATOR 1 20 900 9 10 20 SPARE EWC 1 20 400 11 12 7 20 SPARE RECEPS-LOUNGE 1 20 540 13 14 20 SPARE RECEPS-LOUNGE 1 20 360 15 16 7 20 SPARE PANEL C 80/ 3 2616 17 18 1500 1 20 HAND DRYER 2616 19 20 2762 2 30/ 3 RTU !+ 2616 21 22 2762 SPARE 7 20 23 24 2762 WATER HEATER 6 20/ 2 1000 25 26 8286 80/ 3 RTU 6 1000 27 28 8286 RTU D 80/ 3 8286 29 30 8286 2 8286 31 32 2762 30/ 3 RTU 2 8286 33 34 2762 2 RTU 80/ 3 8286 35 36 2762 8286 37 38 8465 2 100/ 3 PANEL B j 8286 39 40 8465 2 HAND DRYER 1 20 1500 1 41 42 8465 A B C DEMAND: 135.1 KW 375.1A NOTE: THE EXISTING CIRCUIT FOR THE TELEPHONE BACKBOARD RECEPTACLE COULD NOT BE IDENTIFIED. FIELD IDENTIFY THE CIRCUIT. THE CIRCUIT SERVING THE TELEPHONE BACKBOARD RECEPTACLE SHALL REMAIN (NOT BECOME SPARE). PANELBOARD DESIGNATION: B VOLTAGE: 208/120V 3PH-4W MAINS RATING: 200 AMPS MAIN CB TRIP RATING: N/A AMPS ■ SURFACE FLUSH ■ MCB MLO INTERRUPTING RATING: 10,000 AIC ENCLOSURE: NEMA 1 SERVES CB SIZE LOAD VA CKT# CKT# LOAD VA CB SIZE SERVES LTG -WORK SALES AREA 1 4 20 1188 1 2 1089 1 4 20 LTG -SALES 2X4 LTG -WORK SALES AREA 1 4 20 1089 3 4 1386 1 4 20 LTG -SALES 2X4 LTG -WORK SALES AREA 1 4 20 1386 5 6 1287 1 4 20 LTG -SALES 2X4 LTG -WORK SALES AREA 1 4 20 1386 7 8 1386 1 4 20 LTG -SALES 2X4 LTG -WORK SALES AREA 1 4 20 1386 9 10 891 1 4 20 LTG -SALES 2X4 SPARE 7 20 11 12 1400 1 4 20 LTG -PERIMETER SPARE 7 20 13 14 1176 1 4 20 LTG -PERIMETER SPARE 7 20 15 16 1372 1 4 20 LTG -PERIMETER SPARE 20 17 18 20 SPARE SPARE 7 20 19 20 7 20 SPARE SPARE 7 20 21 22 400 3 20 RECEPS-SALES DRINK COOLER SPARE 7 20 23 24 LTG -LOCAL SWITCHED 6 20 1088 25 26 LIGHTING CONTROL(LOCK) 6 20 100 27 28 1 1500 6 4 20 EXTERIOR SIGNAGE LTG -STOCK 6 4 20 1 718 29 30 190 6 4 20 INTERIOR LED DISCS A B C DEMAND: 25.4 KW 70.5A NOTE: NEW SALES LIGHTING CIRCUITS SHOWN USE THE EXISTING SALES LIGHTING CIRCUITS, FIELD VERIFY WHICH EXISTING CIRCUITS ARE AVAILABLE (EXACT CIRCUIT NUMBERS MAY VARY FROM THOSE SHOWN) AS CONSTRUCTION PHASING OCCURS TO NOT DISRUPT STORE OPERATIONS. NEW CIRCUIT BREAKERS AT REMAINING SPACES MAY BE REQUIRED TO FACILITATE PHASING. 'SPARE' CIRCUIT BREAKERS ON THIS PANEL WERE ALSO FORMER SALES LIGHTING. PANELBOARD DESIGNATION: C VOLTAGE: 208/120V 3PH-4W MAINS RATING: 200 AMPS MAIN CB TRIP RATING: N/A AMPS . SURFACE FLUSH ■ MCB MLO INTERRUPTING RATING: 10,000 AIC ENCLOSURE: NEMA 1 SERVES CB SIZE LOAD VA CKT# CKT# LOAD VA CB SIZE SERVES SPARE 7 20 1 2 7 20 SPARE SPARE 7 20 3 4 7 20 SPARE SPARE 7 20 5 6 7 20 SPARE 7 8 200 3 20 FIRE ALARM (LOCK) SPARE 7 20 9 10 20 SPARE SPARE 7 20 11 12 7 20 SPARE RECEPS-CASH WRAP (LOCK) 6 20 720 13 14 40/ 2 SPARE RECEPS-CASH WRAP (LOCK) 6 20 720 15 16 7 RECEPS-EAS (LOCK) 6 20 540 17 18 900 6 20 PLUGMOLD-MGR DESK (LOCK) RECEPS-SALES CEILING 6 20 360 19 20 900 6 20 PLUGMOLD-LP DESK (LOCK) RECEPS-COLUMNS 6 20 540 21 22 900 6 20 PLUGMOLD-MGR BKBD (LOCK) RECEPS-COLUMNS 6 20 540 23 24 900 6 20 PLUGMOLD-MGR TABLE (LOCK) AUTOMATIC DOOR 6 20 315 25 26 AUTOMATIC DOOR 6 20 315 27 28 29 30 A B C DEMAND: 7.8 KW 21.7A NOTE: THE EXISTING CIRCUIT FOR THE TELEPHONE BACKBOARD RECEPTACLE COULD NOT BE IDENTIFIED. FIELD IDENTIFY THE CIRCUIT. THE CIRCUIT SERVING THE TELEPHONE BACKBOARD RECEPTACLE SHALL REMAIN (NOT BECOME SPARE). EXISTING 400A FEED EXISTING O EXISTING EXISTING EXISTING METER CAN PANEL E PANEL D PANEL C 200A MCB 200A MCB 100A MLO 208/120V 208/120V 208/120V EXISTING 3-P, 4-W 3-P, 4-W 3-P, 4-W GROUNDING INSTALL ENGRAVED PLAQUE STATING "BEALLS OUTLET SERVICE 2 OF 2" RELABEL EXISTING PANELS 'D' (FORMERLY 'B') 'E' (FORMERLY 'A') ELECTRICAL RISER DIAGRAM WEATHER HEADS EXISTING EXISTING EXISTING 400A FEED 400A FEED EXISTING 80A FEED 100A FEED EXISTING EXISTING O EXISTING PANEL B PANEL A METER CAN 100A MLO 400A MCB 208/120V 208/120V 3-P, 4-W 3-P, 4-W EXISTING GROUNDING NO SCALE INSTALL ENGRAVED PLAQUE STATING I "BEALLS OUTLET SERVICE 2 OF 2" (D ELECTRICAL SCHEDULES AND DETAILS NO SCALE 13 14 1 5 6 7 8 9 10 1 11 1 12 1 13 1 14 1 15 1 16 1 17 1 18 1 2 P 0 N M L K J H G ME3 CONSULTING ENGINEERS, LLC 5300 Paylor Lane Sarasota, FL 34240 Tel:941-748-1319 Fax:941-361-1221 www.me3-engr.com sidney@me3-engr.com Designed: BAK ME3 Job No: B17-1166 Checked: BAK Date: 09/29/2017 F Drawn: BPZ C.O.A.27552 Copyright 2017 ME3 All rights reserved REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: "To the best of the Architect's or Engineer's knowledge, the plans D and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by local authority in accordance with Chapter 553 and 663 of Florida Statutes." Bryan P. Zapf Florida License # 46141 WBRCI::I ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA BEALLS OUTLET #542 ZEPHYRHILLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B ELECTRICAL SCHEDULES AND DETAILS SHEET TITLE: WBRC CAD FILE: PROJECT No. 3542XX GRAPHIC SCALE: 01. SCALE: As Indicated r I A PROJECT MANAGER: SHEET No. DRAWN BY. El 03 CHECKED BY: 19 20 AI ( FIRE ALARM SPECIFICATIONS & GENERAL NOTES HVAC WIRING GENERAL NOTES 1. DUCT DETECTOR RELAY WIRING SHALL BREAK 24VOLT ELECTRICAL MOUNTING BOX I. GENERAL SCOPE: COIL SECONDARY CONTROL SYSTEM POWER AT THE AIR FOR THE CEILING MOUNTED HANDLER UNIT. NOTIFICATION DEVICES. A. THIS PROJECT WILL REQUIRE THE INSTALLATION OF A NEW FIRE ALARM SYSTEM FOR A RETAIL OUTLET STORE. THE EXISTING SYSTEM WILL BE REMOVED. AS INDICATED ON THESE 2. IF ADDRESSABLE DUCT DETECTORS ARE USED, THE PLANS, BEALLS/BURKES REQUIRES THE INSTALLATION OF A DIGITAL MONITORING PRODUCTS (DMP) XR150DNFC-R SYSTEM. THE PANEL/SYSTEM SPECIFIED IS REQUIRED BY THE OWNER RELAY WILL BE NORMALLY CLOSED DURING IN ORDER TO MAINTAIN CONSISTENCY THROUGHOUT THEIR STORES. DEVIATIONS WILL NOT BE ACCEPTED UNLESS APPROVED, IN WRITING, BY BEALLS/BURKES CONSTRUCTION MANAGER. NON -ALARM CONDITIONS AND OPEN UPON ALARM TO CAUSE A POWER LOSS D THE HVAC CONTROL / BLOWER RELAY CIRCUIT, RESULTING IN FAN AND COMPRESSOR PROVIDE BATTERIES AS REQUIRED BY THE FIRE ALARM BATTERY CALCULATIONS. SHUTDOWN. c PROVIDE BATTERIES AS REQUIRED BY THE POWER SUPPLY EXPANDER CALCULATIONS. 0 3. IF CONVENTIONAL RELAYS (NON -ADDRESSABLE) ARE c 000 THE RELAY SHALL BE NORMALLY OPEN o II. REQUIREMENTS: cu (SED, UNPOWERED) AND SHALL BE HELD CLOSED BY THE vt� FROM THERMOSTAT FIRE ALARM PANEL UNTIL THE DUCT SMOKE �o DETECTOR IS IN AN ALARM CONDITION. A. THE INSTALLATION SHALL CONFORM TO THE INTENT OF NFPA 72 (2010 ED.), THESE PLANS, AND APPLICABLE REFERENCED DOCUMENTS. <w FUSE z� 4. IN SYSTEMS PROVIDED WITH A FAN SHUTDOWN DELAY B. SECONDARY POWER SHALL CONSIST OF RECHARGEABLE BATTERIES HAVING A CAPACITY TO POWER THE ALARM SYSTEM FOR A PERIOD OF 24 HOURS IN A STANDBY MODE AND OPERATE oQ CIRCUIT, A PROGRAMMABLE RELAY SHALL BE PROVIDED IN SERIES WITH THIS EQUIPMENT TO ALL NOTIFICATION APPLIANCES FOR 5 MINUTES AT THE END OF THE 24 HOUR PERIOD. raw BREAK THE CIRCUIT ON ADDRESSABLE SYSTEMS OR "CADDY" T-GRID BOX HANGER o W]L PROVIDED WITH A NORMALLY OPEN RELAY THAT IS SUPPORT, OR EQUAL. "CADDY" C. ALL CIRCUITS SHALL BE "POWER LIMITED". THE CIRCUIT TYPES SHALL BE INSTALLED AS INDICATED BELOW: AHU STEP DOWN 00 TRANSFORMER �ai HELD CLOSED DURING NORMALLY SYSTEM OPERATION ON CONVENTION SYSTEMS. REFERENCE NO. CEC 30-302( 3) INITIATION DEVICE CIRCUITS (IDC'S): CLASS "B" U ACOUSTICAL TILE CEILING NOTIFICATION ALARM CIRCUITS (NAC'S): CLASS "B" JQ GRID SUPPORT FRAMING. D. WALL -MOUNTED NOTIFICATION HORN/STROBES ARE TO BE MOUNTED SO THAT THE ENTIRE LENS OF THE DEVICE IS NO LESS THAT 80" AFF AND NO GREATER THAN 96" AFF. ff oW CEILING -MOUNTED NOTIFICATION DEVICES ARE TO BE MOUNTED AT A MAXIMUM HEIGHT OF 30 FT. (AS INDICATED ON THE PLANS) zL_ E. ALL NEW PULL STATIONS SHALL BE INSTALLED AT 48 INCHES ABOVE THE FINISH FLOOR. F.NG CONNECTIONS ARE TO BE IN SINGLE, DOUBLE, TRIPLE OR 4 INCH ELECTRICAL BOXES, AS NEEDED. WIRING CONNECTIONS OUTSIDE OF ELECTRICAL BOXES WILL NOT BE A B ALLOWED. FIRE ALARM DUCT DETECTOR SHUTDOWN WIRING CEILING GRID ELECTRICAL BACK -BOX ATTACHMENT G. ALL WIRING ON THE INITIATION AND NOTIFICATION CIRCUITS ARE SUPERVISED POWER LIMITED. FA 1 0 1 .NOT TO SCALE FA 1 0 1 NOT TO SCALE H. SURGE SUPPRESSION DEVICES SHALL BE INSTALLED ON ALL CIRCUITS THAT ENTER OR EXIT THE BUILDING. TYPICAL DEVICES ARE LISTED BELOW: PANEL POWER: DITEK MODEL DTK-120SRD, (OR EQUAL) INITIATING CKTS: DITEK MODEL DTK-2MHLP-WB, (OR EQUAL) PHONE LINES: DITEK MODEL DTK-MRJ31 XSCPWP, (OR EQUAL) PANEL POWER SURGE SUPPRESSION MODULE TO BE CONNECTED TO FIRE ALARM CONTROL PANEL; SO THAT WHEN THE MODULE TRIPS, THE FIRE ALARM CONTROL PANEL SHALL REPORT A SUPERVISORY CONDITION. FIRE ALARM CIRCUIT TO JUNCTION BOX NEXT DEVICE I. STROBE CIRCUITS SHALL BE SYNCHRONIZED EITHER THROUGH THE MAIN FACP OR SEPARATE SYNCHRONIZATION MODULES (AS NECESSARY). (OR EQ) III. CONDUIT AND WIRE FIRE ALARM DEVICE MOUNTING GUIDE A. CONDUIT L I LDETECTOR CEIUNG MOUNTED SMOKE/HEAT �3' (MIN) NOT TO SCALE 1. CONDUIT INSTALLATION SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC), LOCAL AND STATE REQUIREMENTS. -1 PER NFPA 72 CEILING 4" 2. CONDUIT FILL WILL NOT EXCEED 40 PERCENT OF INTERIOR CROSS SECTIONAL AREA WHERE THREE OR MORE CABLES ARE CONTAINED WITHIN A SINGLE CONDUIT. 24 MIN HANDICAP UNISTRUT SUPPORT BEDROOM STROBE A/C SUPPLY DIFFUSER ACCEPTABLE HER 4" 3. CABLE MUST BE SEPARATED FROM ANY OPEN CONDUCTORS OF POWER, OR CLASS 1 CIRCUITS, AND SHALL NOT BE PLACED IN ANY CONDUIT, JUNCTION BOX OR RACEWAY MEMBER OR DIRECT AUDIOVISUAL DO NOT INSTA .. CONTAINING THESE CONDUCTORS. ATTACHMENT TO VISUAL -ONLY IN THIS AREA N STRUCTURAL STEEL. DEVICES CEILING MOUNTED NOTIFICA B. WIRE: MOU DEVICE (TO BE WHO :�j. WALL MOUNTED SEE PLAN FOR LOCATION. HEAT DETECTO 1. ALL FIRE ALARM WIRING SHALL BE A MINIMUM OF 'FPLP' TYPE CABLE. CONDUIT DROP TO TO THE BOTTOM. NOTIFICATION DEVICE MINIMUM 3/8" A.T.R. WALL MOUNTED 2. WIRING WILL BE IN ACCORDANCE WITH LOCAL, STATE AND NATIONAL CODESNEC ARTICLE 760). THE NUMBER AND SIZE OF CONDUCTORS SHALL BE AS INDICATED ON THESE (E.G.,( ) DROP TO DEVICE BACKBOX __A 5�_0 SMOKE DETECTOR TO THE TOP. PLANS, BUT SHALL NOT BE LESS THAN #18 AWG FOR INITIATING DEVICE CIRCUITS (INCLUDING SIGNALING LINE CIRCUITS) AND #14 AWG FOR NOTIFICATION DEVICE CIRCUITS. MORE THAN TWO APPLL4NCES IN THE SAME ROOM OR ADJACENT TYP MAX FROM EXIT DOOR SPACE WITHIN THE FIELD OF VIEW 3. ALL FIELD WIRING OF INITIATION AND NOTIFICATION CIRCUITS ARE TO BE COMPLETELY SUPERVISED BY END OF LINE DEVICES, PER THE MANUFACTURER'S LITERATURE. SHALL FLASH IN SYNCHRONIZATION. MANUAL 4. HORIZONTAL WIRE RUNS ABOVE CEILINGS: HORIZONTAL WIRE RUNS IN AREAS CONTAINING DROP CEILINGS MAY BE 'FREE -WIRED' IF SUPPORTED BY TO THE BUILDING STRUCTURE. srnULLL LAYING WIRE ON THE CEILING OR INADEQUATE SUPPORT OF WIRING FROM THE STRUCTURE WILL NOT BE ALLOWED. THIS DETAIL APPLIES TO REMOTE MOUNT AT HEIGHT HORN/STROBE DEVICES 80" MIN 96" MAX ANNUNCIATOR 5. VERTICAL AND HORIZONTAL WIRE RUNS IN OPEN STRUCTURE AREAS: ALL WIRING IN "OPEN TO STRUCTURE AREAS" ON THIS PROJECT SHALL BE INSTALLED IN CONDUIT. INSTALLED IN THE SALES TO MATCH LIGHT FIXTURE ELEVATION NFPA 72 �® AREA. DEVICES IN THE 6. VERTICAL WIRE RUNS: VERTICAL WIRE RUNS TO DEVICES, PANELS, ANNUNCIATORS, ETC. SHALL BE INSTALLED IN CONDUIT PER THE NATIONAL ELECTRICAL CODE. SHIPPING/RECEIVING AREA CAN BE MOUNTED ON FIREAARM C. TERMINAL BOXES, JUNCTION BOXES AND CABINETS: ALL BOXES AND CABINETS SHALL BE UL LISTED FOR THEIR USE AND PURPOSE. BOTTOM OF STRUCTURE. HORNSTROBE SEE " (��G) 80 ABOVE HIGHEST FLOOR PLAN) LEVEL OR 6" BELOW CEILING ; D. THE FIRE ALARM CONTROL PANEL IS TO BE CONNECTED TO A SEPARATE DEDICATED BRANCH CIRCUIT, MAXIMUM 20 AMPERES. THIS CIRCUIT SHALL BE LABELED AT THE MAIN POWER TO THE BOTTOM OF THE x DISTRIBUTION PANEL AS FIRE ALARM. FIRE ALARM CONTROL PANEL PRIMARY POWER WIRING SHALL BE 12 AWG. THE CONTROL PANEL CABINET SHALL BE GROUNDED SECURELY TO EITHER STROBE. WHICHEVER IS LOWER. 48" (ADA) 0 " A COLD WATER PIPE OR GROUNDING ROD. A 120 VOLT SURGE SUPPRESSER SHALL BE INSTALLED ON THE AC POWER AND GROUNDED PRIOR TO ENTERING THE FIRE ALARM CONTROL TO THE WORKING MECHANISM 48" ALSO MEETS THE a 0 as PANEL. THE BREAKER FOR THE ALARM CIRCUIT SHALL BE RED IN COLOR, OR PAINTED RED, SHALL BE ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL, AND SHALL BE IDENTIFIED WITH A REQUIREMENTS OF NFPA 72 PERMANENTLABEL AS "FIRE ALARM CIRCUIT". THE LOCATION OF THE DISCONNECTING MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT VIA A LABEL INSIDE C FINISHED THE PENDENT NOTIFICATION DEVICE MOUNTING FLOOR IV. EXECUTION FA 101 NOT TO SCALE A. INSTALLATION: 1. INSTALLATION SHALL BE IN ACCORDANCE WITH THE NEC, NFPA 72, LOCAL AND STATE CODES, AS SHOWN ON THE DRAWINGS, AND AS RECOMMENDED BY THE MAJOR EQUIPMENT MANUFACTURER. 2. DURING CONSTRUCTION MEASURES SHALL BE TAKEN TO PROTECT SMOKE DETECTORS FROM CONTAMINATION AND PHYSICAL DAMAGE UNTIL CONSTRUCTION ACTIVITIES ARE COMPLETE. V. PROGRAMMING 1. A BASELINE PROGRAMMING MATRIX HAS BEEN INCLUDED ON THESE PLANS. 2. ALL SMOKE DETECTORS SHALL BE PROGRAMMED FOR ALARM VERIFICATION. VI. FINAL INSPECTION 1. AT THE FINAL INSPECTION A FACTORY TRAINED REPRESENTATIVE OF THE INSTALLER SHALL DEMONSTRATE THAT THE SYSTEMS FUNCTION PROPERLY IN EVERY RESPECT. ALL TESTING REQUIRED BY THE AHJ SHALL BE COMPLETED IN THE PRESENCE OF THE LOCAL FIRE AUTHORITY, AS REQUIRED. 2. DUCT SMOKE DETECTORS AND THEIR ASSOCIATED RELAY CONTROL INTERFACE WITH THE ASSOCIATED AIR HANDLER UNIT SHALL BE TESTED PRIOR TO THE FINAL INSPECTION WITH THE LOCAL AHJ. THE PURPOSE OF THE PRE -TEST IS TO ENSURE THE DETECTORS AND SHUTDOWN INTERFACE WITH THE ASSOCIATED AIR HANDLER UNITS ARE FUNCTIONING CORRECTLY PRIOR TO LOCAL JURISDICTION INSPECTION. VII. SYSTEM MONITORING 1. ALARM, SUPERVISORY, AND TROUBLE SHALL BE MONITORED VIA A REMOTE SUPERVISING STATION, AS INDICATED ON THESE PLANS. VIII. GENERAL 1. THE VOLTAGE DROP CALCULATIONS SHOWN ON THE PLANS ARE BASED ON THE CIRCUIT ROUTING SHOWN. MAJOR CHANGES TO THE CIRCUIT ROUTING SHOWN MAY NEED TO BE JUSTIFIED BY THE FIRE ALARM CONTRACTOR WITH ADDITIONAL CALCULATIONS. 2. THE ALARM CONTRACTOR WILL BE REQUIRED TO SUBMIT A "RECORD OF COMPLETION", PER NFPA 72, TO THE OWNER PRIOR TO FINAL PAYMENT. 3. THE FIRE ALARM CONTRACTOR IS REQUIRED TO MAINTAIN A COMPLETE AND ACCURATE AS -BUILT DRAWING SET. UPON FINAL COMPLETION OF THE PROJECT, THE FIRE ALARM CONTRACTOR SHALL SUPPLY THE OWNER & HATCHER ENGINEERING WITH AN AS -BUILT SET PRIOR TO FINAL PAYMENT. AS-BUILTS SHALL INDICATE ALL CHANGES TO THE ORIGINAL LAYOUT INCLUDING, BUT NOT NECESSARY LIMITED TO, AS -BUILT DEVICE LOCATIONS, PANEL LOCATIONS, CIRCUIT ROUTING, CONDUIT ROUTING, JUNCTION BOX LOCATIONS, PANEL CIRCUIT BREAKER LOCATIONS, ETC. 4. ALL CONDUIT AND WIRING PENETRATIONS THROUGH FIRE RATED BARRIERS (INCLUDING WALLS AND FLOORS), AND SMOKE BARRIERS THAT EXTEND FROM FLOOR TO CEILING, SHALL BE SEALED WITH A UL LISTED FIRESTOPPING PENETRATION SYSTEM. THE MINIMUM PENETRATION RATING FOR FIRE RATED BARRIERS SHALL MATCH THE RATING OF THE WALL \ FLOOR \ BARRIER. SMOKE BARRIERS SIMPLY NEED TO BE SEALED TO PREVENT THE PASSAGE OF SMOKE THROUGH THE ASSEMBLY. BEALLS BURKES OUTLET FIRE ALARM SYSTEM INSTALLATION OVERVIEW SCARSDALE SECURITY SYSTEMS INC. OWNER & FIRE ALARM INSTALLER'S RESPONSIBILITIES: STEP TWO: OVERVIEW PROGRAM THE PANEL WITH THE CORRECT LAN SETTINGS (FOR MONITORING BY SCARSDALE SCARSDALE SECURITY SYSTEMS IS THE MONITORING COMPANY FOR ALL BEALL'S & SECURITY): OWNER WILL PURCHASE AND DELIVER (TO THE JOBSITE) THE FIRE ALARM EQUIPMENT FOR BURKES STORES. THE FIRE ALARM SYSTEM MUST BE PROGRAMMED TO REPORT TO EACH PROJECT. SCARSDALE SECURITY WILL BE THE FIRE ALARM EQUIPMENT DEALER. THE THE SCARSDALE CENTRAL STATION AND ALL SIGNALS MUST BE TESTED BEFORE THE THE FOLLOWING IS THE BASIC SETUP INFORMATION REQUIRED PROGRAMMED INTO THE FOLLOWING IS A BASIC RESPONSIBILITY LIST: SYSTEM CAN BE PUT ON LINE. THE PREFERRED TRANSFER PROTOCOL IS CONTACT ID. COMMUNICATOR: OWNER WILL SUPPLY (VIA SCARESDALE SECURITY) THE FOLLOWING: IP COMMUNICATOR LOCAL ADDRESS: ACQUIRE FROM PROJECT MANAGER REQUIRED STEPS: SUBNET MASK: 255.255.255.0 • L GATEWAY: ACQUIRE FROM PROJECT MANAGER • DMP/ALTRONICS 6.5 AMP POWER SUPPLY 1. PROVIDE THE CENTRAL STATION WITH ZONE LIST WITH PANEL MAKE & MODEL. • DMP NOTIFICATION MODULE 2. TEST ALL SIGNALS INTO THE CENTRAL STATION AND CALL TO CONFIRM PROPER STEP THREE: • DMP REMOTE ANNUNCIATOR RECEPTION. • FIRE ALARM DEVICES (PULL STATIONS, SMOKE DETECTORS, DUCT SMOKE DETECTORS, 3. MAKE THE SYSTEM ACTIVE WITH THE CENTRAL STATION. TRIP ALL ZONES INTO THE CENTRAL STATION INCLUDING LOW BATTERY AC FAIL. CALL THE NOTIFICATION DEVICES, MODULES, ETC.) CENTRAL STATION AT 914-722-2222, MAKE THE SYSTEM ACTIVE WITH THE CENTRAL STATION AND • OWNER WILL PREPARE A DEVICE TAKE -OFF LIST FROM THE SHOP DRAWINGS ON EACH TO IDENTIFY THE CORRECT SYSTEM TO THE CENTRAL STATION YOU MUST PROVIDE TELL THEM TO PUT THE FIRE SYSTEM ON LINE. TEST THE CENTRAL STATION REPORTING FOR SYSTEM AND ORDER/DELIEVER DEVICES SPECIFIC TO THIS PROJECT TO THE JOBSITE. THEM WITH THE FOLLOWING INFORMATION: BOTH THE PHONE LINE CONNECTION AND THE ETHERNET CONNECTION. THE FIRE ALARM CONTRACTOR WILL BE RESPONSIBLE FOR THE FOLLOWING: - STORE NAME & NUMBER, CITY & STATE FIRE INSPECTIONS: • PROVIDE ALL LABOR, WIRING, ELECTRICAL BOXES, CONDUIT, WIRE HANGAR SUPPORTS, AND MISCELLANEOUS ELECTRICAL MATERIAL, IN ORDER TO COMPLETE THE INSTALL OF STEP ONE: SPECIAL INSTRUCTIONS FOR SUCCESSFULLY PASSING A FIRE INSPECTION WITH THE FIRE MARSHAL. THE DMP SYSTEM EQUIPMENT PROVIDED BY BEALLS/BURKES. • INSTALLATION PERMIT FROM THE LOCAL MUNICIPALITY. PROVIDE THE CENTRAL STATION WITH A ZONE LIST. IF IT IS SMALL IT CAN BE CALLED THE SYSTEM MUST BE ACTIVE WITH THE CENTRAL STATION THIS MEANS YOU MUST HAVE SENT • PROVIDE FULL SYSTEM INSTALLATION &TESTING IN ACCORDANCE WITH NFPA 72 AND INTO THE CS AT 914-722-2222. IF IT IS LARGE, FAX IT TO 914-722-2299. BE THE CENTRAL STATION A THE LOCAL AHJ. SURE THE ACCOUNT NUMBER IS WRITTEN ON THE FAX. EXAMPLE: 51-5555. ZONE LIST AND TESTED SIGNALS. • PROVIDE ALL PROGRAMMING AND CLOSE OUT DOCUMENTATION. • TEST AND VERIFY FINAL CONNECTION TO THE REMOTE MONITORING STATION YOU MUST ALSO TELL THE CENTRAL STATION THE MANUFACTURER & MODEL NUMBER CALL THE CENTRAL STATION BEFORE THE FIRE INSPECTIONS START AND TELL THEM YOU ARE (SCARSDALE SECURITY). OF THE FIRE ALARM CONTROL PANEL. EXAMPLE: DMP-XR10ONFC TESTING THE SYSTEM WITH THE FIRE MARSHAL TODAY AND CONFIRM THE SYSTEM IS ACTIVE. RECORD YOUR CELL PHONE NUMBER AND COMPANY NAME ON THE ZONE LIST SO THE CS CAN CONTACT YOU IF THEY HAVE A QUESTION ABOUT THE ZONE LIST. MAKE SURE THE CS HAS THE PROPER FIRE DEPARTMENT DISPATCH NUMBER PROPOSED FIRE ALARM I z Z CONTROL MATRIX Z W � > u' I- H Vl � � �+ W 1- J ''^^ z c.� H a Z iZ w o � f- a � vi O H Z Z !- r¢-( � N Z E Q ' Q ¢ U LeJ � Q 2 Z � V~1 W Val z ""e Z Z O 'O Q J z >- o a = O l7 ~� �w z' I I¢ INPUTS O � ¢ W� y � (-+ a Z W �N �= H N A i BI SMOKE DETECTOR C X X DUCT SMOKE DETECTOR D X X X E X X _..._.........----._. F..._._ X i X_ MANUAL PULL STATION G X X 'X H SYSTEM TROUBLE CONDITION I I J PANEL POWER SURGE SUPPRESSION MODULE TRIP K 1 2 3 4 5 6 7' 8 PROJECT SPECIFIC NOTES: I 1. ALL SMOKE DETECTORS ARE TO BE PROGRAMMED WITH ALARM VERIFICATION. 2. THIS CHART IS TO BE USED AS A BASIC PROGRAMMING GUIDE ONLY. ALL OTHER PANEL PROGRAMMING FEATURES SHALL COMPLY WITH NFPA 72 AND THE MANUFACTURERS INSTRUCTIONS. FIRE ALARM DEVICE LEGEND SYMBOL DEVICE TYPE DEVICE MODEL ADDITIONAL NOTES SYMBOL DEVICE TYPE DEVICE MODEL ADDITIONAL NOTES ® FIRE ALARM CONTROL PANEL DMP XR150NFC-R © MAN1',�.I_ PULL STATION DMP 850S WITH 711 ADDRESSABLE MODULE INSTALL AT48^AFF ® REMOTE ANNUNCIATOR PANEL DMP 630E-R INSTALL AT 60" AFF � SYSTEM SENSOR D4120 WITH 711 COORDINATE WITH HVAC CONTRACTOR. INSTALL DETECTOR IN ® SURGE SUPPRESSION MODULE `' D DUCT SMOKE DETECTOR ADDRESSABLE MODULE SUPPLY SIDE DUCT (DOWNSTREAM OF HVAC FAN UNIT) ® FIRE ALARM POWER SUPPLY DMP AX-AL602ULADA (ALTRONICS) � PHOTOELECTRIC SMOKE DETECTOR DMP 521 B CEILING MOUNTED DEVICES TO BE WHITE FLOW SWITCH HORN /STROBE (CEILING MOUNTED) SYSTEM SENSOR BK-PC2W DEVICE TO BE 'WHITE' Q3xp STROBE (CEILING MOUNTED) SYSTEM SENSOR BK-SCW DevlcE To BE'wHIrE� TAMPER SWITCH �/1N� END -OF -LINE RESISTOR (EOL) VENDOR INSTALLED AT END OF CIRCUIT WEATHERPROOF HORN STROBE WALL MOUNTED SYSTEM SENSOR BK-P2RK DEVICE TO BE'RED' a REMOTE TEST/RESET SWITCH SYSTEM SENSOR BK-RTS151 KEY MOUNT ON CEILING BELOW DUCT DETECTOR. LABEL PER RTU #. 1 `J LU NATHANIEL J. HATCHER, P.E. 2108 W. RISK STREET PLANT CITY, FLORIDA FAX: (813) 752 6901� Via° 'y�i ® N0 59350 , e a STATE Ovx\\� ®S®® as � �1f 611 I �e� 10\08\1 7 NATHANIEL J. HATCHER. FL PE #59350 IN I IL Iv I I I IF REV. DESCRIPTION DATE ll ............. .......... E BID & PERMIT SET 09.29.17 CURRENT ISSUE STATUS: PROJECT NORTH ID ®® WBRCM ■C ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com _.._........_Firm Lic_AA26001395 & 27389 __Oou�s W.Whitney _1IA__... BEALLS OUTLET #542 ZE P HYRH I LLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B FIRE ALARM NOTES & SPECIFICATIONS SHEET TITLE: ........._._.......-- ------ ..............._-.................... _......._...... - ---- -- .............---............ WBRCCAD FILE : T:\03Projets-Florida\3501-3600\3542M5BeallsOutletZephyrhillsFL\2Deslgn\Dwgs\Bldg\3542M5 BEALLS OUTLET ZEPHYRHILLS It PROJECT No 3542XX� GRAPHIC SCALE: -t{.._.._._.- ........ _ pl' PROJECT MANAGER: Approver I SHEET No. __....--- .......................__------ DRAWN BY: AJC FA 101 CHECKED BY: NJH ' a n 41 FIRE ALARM WIRE LEGEND SYMBOL CIRCUIT DESCRIPTION CONDUCTORS (AWG) MINIMUM RATING CABLE TYPE* ID INITIATING DEVICE CIRCUIT 2 — #16 FPLP TW -- ---- ---- ---- ---- NAC COMBO AUDIBLE/VISUAL CIRCUIT 2 — #14 FPLP TW DC 24 VDC POWER CIRCUIT 2 — #14 FPLP TW COMM LX—BUS CIRCUIT 4 — #18 FPLP UN RAP KEY PAD BUS CIRCUIT 4 — #18 FPLP ---- X SPARE WIRE PAIR 2 — #14 FPLP TW / SH CABLE TYPE DESIGNATIONS: TW = TWISTED, SH = SHIELDED UN —UNSHIELDED � 19 1 &1 FIRE ALARM PLAN SCALES 1/8' = 1'-0' SCALE: 1 /8" = 1'-0" 2 KEY NOTE DENOTED BY THIS SYMBOL. SEE PLAN. Q lti 1i 18 19 20 NATHANIEL J. HATCHER, P.E. 2108 W. RISK STREET PLANT CITY, FLORIDA TEL: (813) 752-6900 FAX: (813) 752-6911 ®® SAC� #if��%�/ _e i a'o No 5$850 ® e l ® STATE OF ®'a'c FRE SPRINKLER RISER SERI/NG THE SE4LLS OUTLET SPACE. THE 10\08\17 ---0\08----- -- ---- j ASSOC/ATED FLOIV AND_TAMPER NATHANIEL J. HATCHER, FL PE #59350 KEY NOTE LEGEND (THIS SHEET): A. NEW FIRE ALARM CONTROL PANEL. COORDINATE WITH THE E. FIRE ALARM REMOTE ANNUNCIATOR PANEL. COORDINATE WITH OTHER ELECTRICAL PANELS AT THIS LOCATION AND PLACE IN SECURITY PANEL AT THIS LOCATION. THE DESIGNATED SPACE PROVIDED ON THE ELECTRICAL BACK BOARD. F. SMOKE DETECTOR LOCATED AT THE FIRE ALARM CONTROL PANEL. B. NEW POWER SUPPLY EXPANDER. COORDINATE WITH NEW FIRE ALARM CONTROL PANEL AT THIS LOCATION. G. SUPPLY SIDE DUCT SMOKE DETECTOR (TYPICAL FOR AIR HANDLER UNITS OVER 2000 CFM). C. MANUAL PULL STATION PROVIDED AT EACH REQUIRED EXIT. (TYPICAL) H. MONITOR THE FIRE SPRINKLER TAMPERS & FLOW SWITCH ASSOCIATED WITH THE BEALLS SPACE, AS INDICATED. D. CEILING MOUNTED NOTIFICATION DEVICE (TYPICAL WHERE SHOWN). MOUNT ON DROP CEILING OR BOTTOM OF J. WEATHERPROOF EXTERIOR HORN/STROBE PROVIDED AT THE STRUCTURE, WHICHEVER IS LOWER. FRONT OF THE BUILDING. `E A SOUND AT LEAST "5 DB ABOVI AVERAGE AMBIENT SOUND LEVEL. f AVERAGE MERCANTILE OCCUPANCY, H AN AMBIENT SOUND LEVEL OF )BA, A MINIMUM 55DBA SHALL SOUN AUDIBLE NOTIFICATION DEVICES. SE HORN DEVICES TO 'LOW' VOLUME TING DURING INITIAL INSTALLATION. )ITIONAL AUDIBLE VOLUME IS NEEDEI 'IrFq rAN RF AII.IIIgTFn Tn TPF 'NI REV. DESCRIPTION DATE BID & PERMIT SET E 09.29.17 CURRENT ISSUE STATUS: ..__....._._.....1....._.....__.----.... PROJECT NORTH WBRCm M m® ARCHITECTS ENGINEERS 8130 Lakewood Main Street Phone: 941-556-0757 Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 www.wbrcae.com Firm Lic. # AA26001395 & 27389 Douglas Vv'.thime�_AIA BEALLS OUTLET #542 ZEPHYRHILLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 FIRE ALARM PLAN SHEET TITLE: WBRC CAD FILE: 1:13 Projects-Florida\3501-3600\3542M5 Bealls Outlet Zephyrhills FL\2 Design\Dwgs\Bldg\3542M5 BEALLS OUTLET ZEPHYRHILLS.,t PROJECT No 3542X0( GRAPHIC SCALE A SCALE: PROJECT MANAGER: Approver prover i SHEET No. ----._.............._.._ ---___ _ -- -- - DRAWN BY: A,JC FA 102 I CHECKED BY: NJH a i P 0 w M L K J ;v G F E u r.� B 1 'BACKUP' o TELCO MONITORING CONNECTIO TO 120V, N PROVIDE SURGE PROTECTION TO PANEL BATTERIES FIRE COMkVMcorrFx oAAI� o>� ou ® o000 co ®n®co co ®n®® t� ® O &=_I CI (ED REMOTE ANNUNCIATOR FIRE ALARM RISER DIAGRAM 'PRIMARY. NETWORK MONITORING CONNECTION REQUIRED) WIKXM . pus xw 30 CELL RAW BACKUP OF USM) MODEM ROUTER SWITCH PRIMARY FIRE JFWROM BACKUP - LINE ALARM SYSTEM SEIZE FROM MONITORING PER RJ21X PHONE SYSTEM NFPA 72 PUNCH AND BURG FIRE DOWN ALARM ALARMRJ31X " PHONE ...ADDITIONAL LINES TO PHONE SYSTEM... RJ 1X PHONE BLOCKS WHEN PROPERLY WIRED TO ALARM PANELS DISCONNECT THE UPSTREAM DEVICES FROM THE CIRCUIT AND ALLOW THE ALARM PANEL TO "SEIZE", ISSUE A CALLED PARTY DISCONNECT SIGNAL TO ASSURE DIAL TONE AND THEN COMPLETE THEIR CALL WITHOUT INTERRUPTION FROM THE UPSTREAM DEVICES. PHONE SYSTEM A BEALLS BURKES PHONE LINE CONNECTION DIAGRAM FA 10 3 NOT TO SCALE r • • = � 1= =11= =1 1= =1 I• • - �. 2.2K EOLR 110cd 110cd 110cd 110cd J. 0lb 0 0 WPO,k 02.2K EOLR 110cd 110cd 110cd 75cd 110ed MISC. DMP XR150 f XR550 PROGRAMMING NOTES: 1. BELL OPTIONS - FIRE = STEADY 2. OUTPUT OPTIONS - FIRE ALARM OUTPUT = 3 MISC, AX-AL602UADA INSTALL NOTES: 1. INSURE THAT FACTORY INSTALLED JUMPER IS INSTALLED AT DRY1 AND DRY2 CONTACTS ON INPUT HEADER 2. NO WIRING (EXCEPT FACTORY JUMPER AT DRY 2) SHOULD ,BE CONNECTED TO RET1 OR RET2 TERMINALS ON BOTTOM TERMINAL BLOCK 3. SET SYNC MODE DIPSWITCHES TO 1, 2, & 4 "ON", 3 "OFF" (SYSTEM SENSOR SYNC MODE) NOTE: IT IS REQUIRED TO CONTROL VISUAL NOTIFICATION APPLIANCES (STROBES) VIA INPUT 1 (IN1) AND AUDIBLE NOTIFICATION APPLIANCES (HORNS) VIA INPUT 2 (IN2). THIS ALLOWS AUDIBLE NOTIFI%RATION APPLIANCES TO BE SILENCED WHILE VISUAL NOTIFICATION APPLIANCES CONTINUE TO OPERATE. DMP XR150DNFC-R INSTALLATION TROUBLESHOOTING: A. INDICATING APPLIANCES DO NOT ACTIVATE WHEN A FI TYPE ZONE IS PLACED IN ALARM 1. CHECK THAT BELL OUTPUT HAS AN ACTION OF STEADY OR PULSE. (DEFAULT IS PULSE) 2. CHECK FOR 12VDC OUTPUT ON TERMINALS 5 AND 6 OF THE PANEL. 3. CHECK FOR 12VDC ON TERMINALS 3 AND 2 OF THE 866. 4. CHECK FOR 12VDC OUTPUT ON TERMINALS 5 AND 6 OF THE 866. B. 12VDC OUTPUT ON TERMINALS 5 AND 6 OF THE PANEL 1. CHECK FOR 12VDC ON TERMINALS 1 AND 2 OF THE 866. 2. CHECK FOR 12VDC ON TERMINALS 4 AND 2 OF THE 866. C. INDICATING APPLIANCES HAS A DELAY BEFORE ACTIVATION 1. CHECK TERMINALS 7 AND 8 OF THE 866 FOR A CLOSED CIRCUIT. 2. IF CIRCUIT IS OPEN, CHECK 10K RESISTOR IS INSTALLED FOR TERMINALS 5 AND 6 OF THE 866. ENSURE 866 SILENCE SWITCH IS SET TO NORMAL. 3. WHEN METERING TERMINAL 5 AND 6 OF THE 866, A NEGATIVE VOLTAGE IS OBSERVED UNTIL VOLTAGE IS APPLIED TO TERMINAL 3 IN WHICH THE SENSING VOLTAGE REVERSES AND YOU HAVE OUTPUT, PROVIDED A POSITIVE VOLTAGE IS APPLIED TO TERMINAL 4 OF THE 866. 2 3 4 5 6 7 8 XR550/XR150 Series Control Panel Relay Outputs 1-2 (ON) Switching Grounds 3-6 (ON) Active Zones 1-8 Active Zones 9-10 2-Wire Smokes Panel Bell Output 893A Dual Phone Line Module 865 Style Y or Z Notification Module 866 Style W Notification Module 867 LX-Bus Style W Notification Module 869 Class A Style D Module 630F Remote Fire Command Center 710 Bus SpLitter/ Repeater 71OF Fire Bus SpLitter/ Repeater 711 Zone Expander Active Zones (EOL installed) 716 Output Expander Active Form C Relays 717 Graphic Annunciator Annunciator Outputs 860 Relay Module (Active Relays) 521 LX, 521 LXT Smoke Detectors Required Minimum Alarm Time in minutes 13 VOLTAGE DROP CALCULATIONS Project Name Bealls Outlet #542 - Zephyrhills, FI CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Date 09/26/17 Circuit Number NAC#1 Totals Current Distance 0.000 196 ft. Voltage Drop 0.44 Totals Voltage Drop 0.870 Totals Voltage Drop 0.435 Specific Area Receiving, Manager, Hall, Restroom, and Lounge Current 0.723 Distance 196 Current 0.723 Distance 196 Nominal System Voltage (Vdc) 20.4 Minimum Device Voltage (Vdc) 14 Maximum Allowable Load this NAC Circuit (Amps) 3.0 Wire Ohm's Gauge Per 1000 Distance from source to 1st device [77TS 14 3.07 End of Line Voltage 19.96 End of Line Voltagel 19.53 End of Line Voltagel 19.96 Percent Dropl 2.14% Percent Dropl 4.27% Percent Dropl 2.13% use only the wire guage for the first device to source stance in Ohms per 1000 feet. 18=7.77 16=4.89 14=3.07 12=1.98 10=1.24 18-14 Awg = Solid Conductors 12-10 Awg = Stranded Conductors Wire Gauge for balance of circuit 14 3.07 Enter current in amps. .150 = 150 ma Distance from previous device Voltage At Drop from Percent Device source Drop Notes: Wire resistance is doubled in the calculations for two wires (Positive and Negative) The voltage calculated to the last device in any method must not be lower then the manufactures listed minimum operating wltage (IE: rated operating voltage 20-32 VDC). DEVICE LIST FOR THIS CIRCUIT Device Current System Sensor 95cd - Ceiling Horn/Strobe 0.194 System Sensor 75cd -Ceiling Strobe 0.066 System Sensor 75cd - Ceiling Strobe 0.158 System Sensor 15cd - Ceiling Horn/Strobe 0.079 System Sensor 75cd - Ceiling Strobe 0.066 System Sensor 15cd - Ceiling Strobe 0.066 System Sensor 30cd - Ceiling Strobe 0.094 TOTAL LOAD OF ALL DEVICES 0.5 Amp 15 20.33 0.067 0.33% 56 20.15 0.248 1.22% 24 20.08 0.317 1.55% 24 20.04 0.362 1.77% 24 20.01 0.395 1.94% 25 19.98 0.420 2.06% 281 19.96 1 0.436 2.14% 196 ft. End of Line Voltag4 19.96 Vdc Point to Point Method End of Line Method Load Centering Method Project Name Bealls Outlet #542 - Zephyrhills, FI CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Date 09/26/17 Circuit Number NAC#2 Totals Current Distance 0.000 273 ft. Voltage Drop 0.92 Totals Voltage Drop 1.388 Totals Voltage Drop 0.694 Specific Area Sales Area Current 0.828 Distance 273 Current 0.828 Distance 273 Nominal System Voltage (Vdc) 20.4 Minimum Device Voltage (Vdc) 14 Maximum Allowable Load this NAC Circuit (Amps) 3.0 Wire Ohm's Gauge Per 1000 Distance from source to list device 89 14 3.07 End of Line Voltage 19.48 End of Line Voltage 19.01 End of Line Voltage 19.71 Percent Drop 4.49% Percent Drop 6.80% Percent Drop 3.40% End of Line and Load Centering Methods use only the wire guage for the first device to source Standard Wire Resistance in Ohms per 1000 feet. 18=7.77 16=4.89 14=3.07 12=1.98 10=1.24 18-14 Awg = Solid Conductors 12-10 Awg = Stranded Conductors Wire Gauge for balance of circuit 14 3.07 Enter current in amps. Distance .150 = 150 ma from Voltage DEVICE LIST FOR THIS CIRCUIT Device previous At Drop from Percent Current device Device source Drop System Sensor 11Ocd - Ceiling Horn/Strobe 0.212 89 19.95 0.452 2.22% System Sensor 110cd - Ceiling Strobe 0.202 62 19.71 0.687 3.37% System Sensor 110cd - Ceiling Horn/Strobe 0.212 60 19.56 0.839 4.12% System Sensor 110cd - Ceiling Strobe 0.202 62 19.48 0.916 4.49% TOTAL LOAD OF ALL DEVICES 0.83 Amp 273 ft. End of Line Voltage 19.48 Vdc Notes: Wire resistance is doubled in the calculations for two wires (Positive and Negative) The voltage calculated to the last device in any method must not be lower then the manufactures listed minimum operating wltage (IE: rated operating voltage 20-32 VDC). Project Name Bealls Outlet #542 - Zephyrhills, FI CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Date 09/26/17 Circuit Number NAC#3 Totals Current Distance 0.000 309 ft. Voltage Drop 1.11 Totals Voltage Drop 1.571 Totals Voltage Drop 0.785 Specific Area Sales Area Current 0.828 Distance 309 Current 0.828 Distance 309 Nominal System Voltage (Vdc) 20.4 Minimum Device Voltage (Vdc) 14 Maximum Allowable Load this NAC Circuit (Amps) 3.0 Wire Ohm's Gauge Per 1000 Distance from source to 1st device 125 14 3.07 End of Line Voltage 19.29 End of Line Voltage 18.83 End of Line Voltage 19.61 Percent Dropl 5.43% Percent Dropl 7.70%1 Percent Dropl 3.85% End of Line and Load Centering Methods use only the wire guage for the first device to source Standard Wire Resistance in Ohms per 1000 feet. 18=7.77 16=4.89 14=3.07 12=1.98 10=1.24 18-14 Awg = Solid Conductors 12-10 Awg = Stranded Conductors Wire Gauge for balance of circuit L14 3.07 Enter current in amps. .150 = 150 ma Distance from Voltage Notes: At Drop from Percent Device source Drop The Wire resistance is doubled in the calculations for two wires (Positive and Negative) voltage calculated to the last deuce in any method must not be lower then manufactures listed minimum operating wltage (IE: rated operating voltage 20-32 VDC). DEVICE LIST FOR THIS CIRCUIT Device previous Current device System Sensor 110cd - Ceiling Strobe 0.202 125 System Sensor 11 Ocd - Ceiling Horn/Strobe 0.212 62 System Sensor 11 Ocd - Ceiling Strobe 0.202 60 System Sensor 110cd - Ceiling Horn/Strobe 0.212 62 TOTAL LOAD OF ALL DEVICES 0.83 Amp 309 ft. 19.76 0.635 3.12% the 19.53 0.874 4.28% 19.37 1.026 5.03% 19.29 1.107 5A3% End of Line Voltagl 19.29 Vdc Project Name Bealls Outlet #542 - Zephyrhills, Fill CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Date 09/26/17 Circuit Number NAC#4 Totals Current Distance 0.000 401 ft. Voltage Drop 1.1 Totals Voltage Drop 2.472 Totals Voltage Drop 1.236 Specific Area Sales Area Current 1.004 Distance 401 Current 1.004 1 Distance 401 Nominal System Voltage (Vdc) 20.4 Minimum Device Voltage (Vdc) 14 Maximum Allowable Load this NAC Circuit (Amps) 3.0 Wire Ohm's Gauge Per 1000 Distance from source to 1st device 171 1 14 3.07 Wire Gauge for balance of circuit 1 14 3.07 Enter current in amps. Distance .150 = 150 ma from Voltage Notes: DEVICE LIST FORTH IS CIRCUIT Device previous At Drop from Percent Wire Current device Device source Drop The System Sensor 110cd - Ceiling Horn/Strobe 0.212 171 19.35 1.054 5.17% the System Sensor 11 Ocd - Ceiling Strobe 0.202 62 19.04 1.356 6.65% System Sensor 110cd - Ceiling Horn/Strobe 0.212 60 18.83 1.573 7.71% System Sensor 75cd - Wall Horn/Strobe 0.176 47 18.72 1.682 8.25% System Sensor 11 Ocd - Ceiling Strobe 0.202 61 18.64 1.758 8.62% TOTAL LOAD OF ALL DEVICES 1 Amp 401 ft. End of Line Voltage 18.64 Vdc End of Line Voltage 18.641 End of Line Voltage 17.93 End of Line Voltage 19.16 Percent DropI 8.62%1 Percent Dropl 12.12% Percent DropI 6.06% End of Line and Load Centering Methods use only the wire guage for the first device to source Standard Wire Resistance in Ohms per 1000 feet. 18=7.77 16=4.89 14=3.07 12=1.98 10=1.24 18-14 Awg = Solid Conductors 12-10 Awg = Stranded Conductors resistance is doubled in the calcul-tiPRs for two wires (Positive and Negative) voltage calculated to the last devic_ any method must not be lower then manufactures listed minimum operating voltage (IE: rated operating wltage 20-32 VDC). BATTERY CALCULATIONS (DMP FACP PANEL) (ALTRONICS POWER SUPPLY EXPANDER) Qty 1 X 180 mA 180 mA Qty 1 X 180 mA 180 mA Qty 0 X 30 mA 0 mA Qty 0 X 30 mA 0 ITA Qty 0 X 5 mA 0 mA Qty 0 X 5 mA 0 mA Qty 0 X 1.6 mA 0 mA Qty 2 X 2 mA 4 mA* Qty 2 X 4 mA 8 mA Qty 2 X 30 mA 60 mA* Qty 0 X 0.1 mA 0 mA Qty 0 X 0.1 mA 0 mA* Amount of Bell Current drawn 1500mA Maximum 1500 mA mA Qty 0 X 35.5 mA 0 mA Qty 0 X 35.5 mA 0 mA Qty 0 X 26 mA 0 mA Qty 0 X 85 mA 0 mA Qty 1 X 45 mA 45 mA Qty 1 X 76 mA 76 mA Qty 0 X 30 mA 0 mA Qty 0 X 86 mA 0 mA Qty 0 X 25 mA 0 mA Qty 0 X 75 mA 0 mA Qty 1 X 63 mA 63 mA Qty 1 X 92 mA 92 mA Qty 0 X 30 mA 0 mA Qty 0 X 30 mA 0 mA Qty 0 X 40 mA 0 mA Qty 0 X 40 mA 0 mA Qty 12 X 11 mA 132 mA Qty 12 X 11 mA 132 mA Qty 12 X 1.6 mA 19.2 mA Qty 12 X 2 mA 24 mA* Qty 0 X 7 mA 0 mA Qty 1 X 13 mA 13 mA Qty 0 X 12 mA 0 mA Qty 0 X 10 mA 0 mA Qty 0 X 10 mA 0 mA Qty 0 X 1 mA 0 mA Qty 0 X 34 mA 0 mA Qty 0 X 34 mA 0 mA Qty 0 X 34 mA 0 mA Qty 1 X 8.8 mA 8.8 mA Qty 1 X 28 mA 28 mA* Total St andbyl 456 mA Total Alarm I 609 mA 5 Minutes Number of standby hours needed 24 Total number of standby mA hours 10944 Total required alarm current 51 Total number of mA hours 10995 Contingency factor 1 20%1 13194 Minimum Battery Amp hours required 13 hours mA-Hour mA-Hour mA-Hour mA-Hour Amp -Hour MINIMUM BATTERY SIZE. PROVIDE NEXT SIZE UP TO COVER THIS MINIMUM. 9 ' 10 11 12 13 14 DMP AX-AL602ULADA SERIES BATTERY CACLULATIONS Job #: 2017-1474 Job Title: BEALLS OUTLET #542 ZEPHYRHILLS, FL Number of Device Devices Current per Device Standby Current Alarm Current Standby: 90 mA 90 mA AL602ULADA 1 Alarm: 175 mA 175 mA A AL602 Current 90 mA 175 mA Standby: 21 mA 105 mA D4120 Duct Smoke Detector 5 Alarm: 65 mA 325 mA B Auxiliary Devices Current (must not exceed 1 amp) 105 mA 325 mA NAC #1 Alarm: 0.5 A 500 mA NAC #2 Alarm: 0.83 A 830 mA NAC #3 Alarm: 0.83 A 830 mA NAC #4 Alarm: 1 A 1000 mA C Notifacation Appliances Current must not exceed 6.5 amp (6500mA) 3160 mA D Total Standby Current 195 mA E Total Alarm Current 3660 mA F Total current ratings converted to Amperes 0.195 A 3.66 A Required Minimum Alarm Time in Minutes: 5 Minutes Standby Hours Needed 24 Hours Total number of standby mA hours 4.68 Amp -Hour Total required alarm current 0.31 Amp -Hour Total number of mA Hours 4.99 Amp -Hour Contingency Factor = 20% 1.00 Amp -Hour Minimum Battery Amp Hours Required 6 Amp -Hour 15 16 MINIMUM BATTERY SIZE. PROVIDE NEXT SIZE UP TO COVER THIS MINIMUM. Ifl 18 19 20 NATHANIEL J. HATCHER, P.E. 2108 W. RISK STREET PLANT CITY, FLORIDA TEL (813) 752-6900 FAX: (813) 752 6911 3ACE 10GEC ®®®NN ��®1 i ® a No 593W 0 A � OF®_ �OzlSTATE RtID Nam`®� NATHANIEL J. HATCHER, FL PE #59350 Q L. M L K J G REV. DESCRIPTION DATE BID & PERMIT SET 'E 09.29.17 CURRENT ISSUE STATUS: I PROJECT NORTH 0 ARCHITECTS ENGINEERS 8130 Lake��°ood R�1ain Street Phone: 9� 1-556-0757 I Suite 210 Fax: 941-556-0759 Lakewood Ranch, FL 34202 wwW.wbrcae.com Firm Lic. AA26001395 & 27389 Dauglas W_ Vhitney 1A BEALLS OUTLET #542 ZEPHYRHILLS PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 e FIRE ALARM RISER DIAGRAM & CALCULATIONS SHEET TITLE: WBRC CAD PILE: 11, Projects-Florida\3501-36=3542M5 Bealls Outlet Zephyrhills FL\2 Design\Dwgs\B1dg\3542M5 BEALLS OUTLET ZEPHYRHILLS.,t PROJECT No. 3542XX GRAPHIC SCALE: 1 C, A SCALE: XV - 1'-0" PROJECT MANAGER: Approver SHEET No. DRAWN BY: AJC FA 10 3 ,. CHECKED BY: NJH rz „ 19 20