HomeMy WebLinkAbout7631 Gall Blvd (23)I 0 0 0 V) 0 0 U cn � U)� 0 " r 0 w r z Q ii00 00 Ln N N `_- 00 0 C- N T L0 0- N � N o� W n1 > I Q(.D cn 0 rl- Q00 0 0 C6 6 N 0 0 �_:E m3 V) n U 0 0 0 r�i C)_ 00 � 0 /v, N � U o a � 3 W N F- ) z Q it ZEPHYRHILLS, FLORIDA STORE NO.: 0706=236 ARCHITECTURAL C1 COVER SHEET Al FLOOR PLANS A1.1 GRID WALL PLAN FIRE PROTECTION FP1 FIRE PROTECTION PLANS ELECTRICAL - El ELECTRICAL PLANS RACKING STRUCTURAL- FXS1 FIXTURE ANCHORAGE PLAN DETAILS AND NOTES F E ''I''Ir SPECIAL PROJECT GENERAL REQUIREMENTS DEMOLITION REQUIREMENTS 1. ALL WORK SHALL BE DONE IN A SAFE AND WORKMANLIKE 7. REMOVE ANY EXISTING EQUIPMENT, FIXTURES, FURNISHINGS, MANNER AND IN STRICT ACCORDANCE WITH THE LOCAL ACCESSORIES, SERVICES, FINISHES OR SURFACES AS REQUIRED, 1. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER AND/OR STATE (IF APPLICABLE) BUILDING CODES, NATIONAL SHOWN OR NOT SHOWN, FOR THE INSTALLATION OF NEW AND IN STRICT ACCORDANCE WITH OSHA REGULATIONS. ELECTRIC CODE, ADA—ADAAGS AND OTHER ADOPTED CONSTRUCTION. ACCESSIBILITY STANDARDS, OSHA, AND ALL APPLICABLE 2. THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF CODES, REGULATIONS, ORDINANCES AND AUTHORITIES 8. WHEN EQUIPMENT, FIXTURES, FURNISHINGS, ACCESSORIES, DEMOLITION, THE WORK INCLUDES, BUT IS NOT LIMITED TO, THE HAVING JURISDICTION. SERVICES, FINISHES OR SURFACES ARE TEMPORARILY REMOVED OR DEMOLITION AND REMOVAL OF WALLS, DOORS, FIXTURES, RELOCATED IN ORDER TO PERFORM WORK, THE CONTRACTOR IS PLUMBING, PAVING, MECHANICAL AND ELECTRICAL ITEMS 2. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A RESPONSIBLE FOR RETURNING THEM TO THEIR ORIGINAL POSITION, INCLUDING CONDUITS AND DUCTWORK AS SHOWN ON DRAWING THOROUGH KNOWLEDGE OF ALL DRAWINGS AND RECONNECTION OF SERVICES AND APPROPRIATE MEANS OF OR AS REQUIRED FOR THE INSTALLATION OF THE NEW WORK SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ATTACHMENT UNLESS SPECIFICALLY DIRECTED TO DO OTHERWISE. FOR A COMPLETE JOB. ACQUAINT HIMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE HIM OF ANY RESPONSIBILITY FOR PERFORMING HIS WORK 9. REPAIR, RE—ROUTE, AND EXTEND ALL SERVICES, PIPING, CONDUIT 3. WHEN UTILITIES ARE REMOVED, CAP AND SEAL A MINIMUM OF PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE OF EXISTING ITEMS AND EQUIPMENT AS REQUIRED DURING THE FINISH ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO CONSTRUCTION PROCESS TO MAINTAIN NORMAL STORE OPERATIONS 8" BELOW FLOOR OR A MINIMUM OF 6" ABOVE FINISH FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. AND AS REQUIRED FOR THE INSTALLATION OF NEW CEILING. CONSTRUCTION. THIS INCLUDES ALL ITEMS SHOWN OR NOT SHOWN 3. THE EXISTING BUILDING SHALL BE PROTECTED FROM ON THE DRAWINGS. RESET EXISTING EQUIPMENT, FIXTURES, 4. WHEN REMOVING EXISTING STRUCTURAL ITEMS, IT IS THE MOISTURE, DUST AND DEBRIS. REF 2—A1.1 FURNISHINGS, ACCESSORIES OR RELATED ITEMS AS REQUIRED FOR CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE PROPER OPERATION. SHORING, BRACING AND SUPPORT SYSTEMS TO KEEP THE 4. ANY DAMAGE TO WALMART'S PROPERTY, WHICH OCCURS EXISTING STRUCTURE INTACT AND IN A SAFE CONDITION. DURING THE PROCESS OF CONSTRUCTION SHALL BE 10. WHERE EXISTING FINISHES ARE TO REMAIN, CLEAN, REPAIR, REFER TO SECTIONS 02023 AND 02251. REPAIRED/REPLACED AT NO ADDITIONAL COST TO WALMART; PATCH AND REPAINT AS NECESSARY TO BLEND IN WITH ADJACENT THIS INCLUDES ALL MERCHANDISE. CONTRACTOR SHALL PAY WORK. 5. NOTES INDICATING DEMOLITION WORK ARE NOT CONFINED THE COST FOR ALL DAMAGED MERCHANDISE. SOLELY TO THE DEMOLITION PLANS. THE GENERAL CONTRACTOR 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELY SHALL REVIEW ALL CONSTRUCTION DOCUMENTS, INCLUSIVE OF 5.THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE ORDERING OF MATERIALS TO PROHIBIT DELAYS OF THE SCHEDULES AND SPECIFICATIONS, TO DETERMINE FULL EXTENT EXISTING BUILDING SECURITY AT ALL TIMES. THIS INCLUDES CONSTRUCTION SCHEDULE OF THIS PROJECT. IT IS THE OF DEMOLITION WORK. KEEPING THE BUILDING SECURE FROM PERSONS, RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE DELIVERY OF ENVIRONMENTAL ELEMENTS OR HAZARDS. THE CONTRACTOR MATERIALS IN A TIMELY MANNER. SHALL BE RESPONSIBLE TO MAINTAIN THE INTEGRITY OF ALL 12. THE GENERAL CONTRACTOR SHALL RESPOND TO ALL EXISTING SECURITY SYSTEMS. THE CONTRACTOR SHALL REQUIREMENTS OF THE ARCHITECT/ENGINEER FOR VERIFICATIONS, OBTAIN PERMISSION FROM THE STORE MANAGER PRIOR TO RESPONSES, AND SUBMISSIONS. THE MODIFICATION OF ANY EXISTING SECURITY SYSTEM. 13. DURING ENTIRE CONSTRUCTION PERIOD, PROVIDE ONE U.L. 6.PROVIDE CONSTRUCTION BARRIER AS REQUIRED PER THE LISTED 2A:2OBC DRY CHEMICAL FIRE EXTINGUISHER, OR ONE OWNER. AREA IS TO BE MADE SAFE FOR ALL ASSOCIATES AND STANDARD U.L. LISTED 2-1/2 GALLON WATER (E-10) AND ONE U.L. CUSTOMERS. THE CONTRACTOR SHALL KEEP THE WORK AREA LISTED 1OBC CARBON DIOXIDE FIRE EXTINGUISHER MOUNTED CLEAN AND FREE OF DEBRIS AND REMOVE ALL TRASH AND TOGETHER IN EACH 3000 SO. FT. OF WORK AREA OR FRACTION DEBRIS FROM THE CONSTRUCTION AREA DAILY. NO THEREOF (MINIMUM OF TWO AVAILABLE IN ALL CONSTRUCTION FLAMMABLE MATERIALS OR LIQUIDS MAY BE STORED IN THE AREAS AT ALL TIMES). EXISTING BUILDING. 14, IF MODIFICATION TO SPRINKLER SYSTEM IS REQUIRED THE GENERAL CONTRACTOR SHALL HIRE A LICENSED SPRINKLER CONTRACTOR. CONTRACTOR TO COORDINATE WITH LOCAL JURISDICTION FOR REQUIRED SUBMITTALS AND PERMITS. NTS BUILDING CODE SUMMARY NAME OF PROJECT: FET SPECIAL PROJECT STREET ADDRESS: 7631 GALL BOULEVARD ZYPHERHILLS, FLORIDA 33541 PROPOSED USE: RETAIL BUILDING: 2017 FLORIDA BUILDING CODE, 6TH EDITION FIRE: 2017 FLORIDA FIRE CODE, 6TH EDITION MECHANICAL: 2017 FLORIDA BUILDING CODE, 6TH EDITION — MECHANICAL ELECTRICAL: 2014 NATIONAL ELECTRIC CODE NFPA 70 PLUMBING: 2017 FLORIDA BUILDING CODE, 6TH EDITION — PLUMBING LIFE SAFETY: 2018 NFPA 101 ACCESSIBILITY: 2017 FLORIDA BUILDING CODE, 6TH EDITION — ACCESSIBILITY ENERGY: 2017 FLORIDA BUILDING CODE, 6TH EDITION — ENERGY OCCUPANCY: M —MERCANTILE TYPE OF CONSTRUCTION: 5B—UNPROTECTED FULLY SPRINKLERED ARCHITECTURAL: FIRE PROTECTION: ELECTRICAL: RACKING STRUCTURAL: BUILDING REVIEW: STORE ADDRESS: pb2 architecture + engineering pb2 architecture + engineering pb2 architecture + engineering WALLACE ENGINEERING CITY OF ZYPHERHILLS WALMART STORE NO. 0706 2809 AJAX AVENUE, SUITE 100 2809 AJAX AVENUE, SUITE 100 2809 AJAX AVENUE, SUITE 100 200 EAST MATHEW B. BRADY STREET BUILDING DEPARTMENT 7631 GALL BOULEVARD ROGERS, AR 72758 ROGERS, AR 72758 ROGERS, AR 72758 TULSA, OKLAHOMA 74103 5335 8th STREET ZYPHERHILLS, FLORIDA 33541 (479) 636-3545 (479) 636-3545 (479) 636-3545 (918) 584-5858 ZYPHERHILLS, FLORIDA 33542 (813) 780-0020 REMODELED SQ FT: EXISTING SQ FT: DATE: FLOOR PLAN VICINITY MAP L€ we's Home u Improvement Great Cli Salon pes'0z Ht rn� impr .ern�rrl &.. hairca p�q ! Publx Su fir t��uk❑ray Ave,` yr I .Zephcr at Zephy Corey ewt Av@ Chase Bank �.. a Ave fWalmart Supercenter 1 SmartStyl�e Hair Salad 1.11s 4 rim tirngRcs & more I -R s Tractor Supply Co �. Pretty Pare Rd RrJral Kirk - 5,407 205,831 09mO7ml 8 GENERAL SCOPE OF WORK • SALES FLOOR: REMOVE EXISTING MANNED CHECKOUTS AND SELF CHECKOUTS. INSTALL BULLPEN WITH SELF —CHECKOUT STATIONS. INSTALL SELF —CHECKOUT LANES. INSTALL AUTOMATED PICKUP EQUIPMENT. GENERAL NOTES 1. BUILDING WILL BE FULLY SPRINKLERED BEFORE, DURING AND AFTER CONSTRUCTION. 2. CASH WRAPS SHALL BE FURNISHED AND INSTALLED BY WALMART. 3. ELECTRICAL CONTRACTOR TO PROVIDE THIRD PARTY ELECTRICAL INSPECTION. 4. PATCH AND REPAIR FLOORING AS NEEDED. VIEW DATE 6 CITY OF ZEPHYRHILLS / ,FIRE AND LIFE SAFETY EXAMINE--✓- ` MpLy WITH ALL NF A® O ODES AND STANDARDS ALL WORK SHALL GONIPLY WITH PREVAILING CODES FLORIDA t3UiLDiNG CODES REVIEW DATE C/ � NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS CITY OF ZEPHYRH;L c ORDINANCES N'v rEXAM'LR H V W 7 O GG d J Q V W H W UM Pb2 architecture +engineering 2809 Ajax Avenue Suite 100 Rogers Arkansas 72758 Phone: 479.636.3545 Fax: 479.636.1209 Architect of Record William Douglas Hurley Florida License No. AR91919 Architect Business Lic No. AA26000940 w w w p UW) Npz� ~o< � w0 NZ�F Zwcn�=Z3 W o �2L m aVvw~aa Df w�- i-�`W, Z��pZ�J �Q 2 �QMOw- QNW elfw 3 z a-J O w N U Z K I- 0 _ po L� a�oJaZp, z��ajwxo n�N0�wa3anpwpNar z 3��on�o<MXjzair�aa 0 w4Z0 ~ Z fn VI Q OrO H V) '2 Q < =J0ZW�F�� Ju)w�nop c� a- �O wOmwOwwwwZwm Nwa Z H ~ 0wlwi 000 <0>- U1 ��UJ0<vpiaLnL'aawoa< 0 O � O O � W O d' cc � o w N z 0 ISSUE BLOCK CHECKED BY: GK DRAWN BY: AMR FILE NAME: CO10 PROTO CYCLE: 072718 DOCUMENT DATE: 09-07-18 F #� 0 PO �a DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION COVER SHEET SHEET: C 1 OWNER SUPPLIED ITEMS LEGEND GENERAL NOTES SHEET NOTES MARK COUNT DESCRIPTION MODEL VENDOR VENDOR NUMBER 1. BUILDING IS FULLY SPRINKLED AS REQUIRED BY CONTRACT 1 AUTOMATED EQUIPMENT TOWER - - - CLEVERON - - - EXISTING TO REMAIN DOCUMENTS. SUBMIT REVISED FIRE SPRINKLER SYSTEM DRAWINGS 1. ALL ELECTRICAL WORK INCLUDING DATA AND 32 LOCKING CABINET CC10.01 CLEVERON - - - NEW AND CALCULATIONS TO AUTHORITIES HAVING JURISDICTION. (FIRE POWER DISCONNECTION BY GENERAL CONTRACTOR. 2 DEPARTMENT, FIRE MARSHAL, ETC). OBTAIN ALL APPROVALS PRIOR 2 REMOVAL AND REINSTALLATION OF POWER - - - DEMOLISH/REMOVE TO FABRICATION OR INSTALLATION. PRECEDING ANY SPRINKLER POLES BY GENERAL CONTRACTOR. INSTALLATION architecture OWNER SUPPLIED MATERIALS _.._.._.._ RELOCATE WORK, CONTRACTOR TO CONTACT LOCAL FIRE MARSHAL TO OF NEW POWER POLES BY GENERAL +en ineerin COORDINATE WHEN FIRE SUPPRESSION SYSTEM IS OFFLINE g g TEMPORARILY. CONTRACTOR. MARK COUNT DESCRIPTION MODEL VENDOR VENDOR NUMBER 3. ALL REGISTERS TO BE REMOVED AND 2809 Ajax Avenue Suite 100 REINSTALLED OR INSTALLED NEW BY WALMART. Rogers Arkansas72758 LVT1 720 SQ FT FAUX WOOD FLOORING D44 THE MATWORKS COMPANY, LLC 1000177354 PICKUP WALL SYSTEM INFO 2. OWNER WILL PROVIDE, OR HAS ALREADY PROVIDED, FIRE 4. GENERAL CONTRACTOR RESPONSIBLE FOR ALL Phone:479.636.3545 EXTINGUISHERS IN. ACCORDANCE WITH NFPA 10. AUTHORITY HAVING ELECTRICAL WORK. Fax:479.636.1209 JURISDICTION WILL APPROVE FINAL FIRE EXTINGUISHER LOCATIONS. Architect of Record HAINES, JONES & CADBURY 5. GENERAL CONTRACTOR RESPONSIBLE FOR 18 ANCHORS AND ALL GONDOLA ANCHORAGE. William Douglas Hurley 4' WALL PANELS IDX HAINES, JONES & CADBURY 1000121534 HJC/WALMART CUSTOMER SERVICE TEAM 3. CONTRACTOR RESPONSIBLE FOR PERMITS AND TRADE LICENSES 6. GENERAL CONTRACTOR TO REPAIR FLOOR AS Florida License No. AR91919 WMCSRQHJCINC.COM, 800-459-7099 THROUGH LOCAL JURISDICTION Architect Business Lic No. MANUF: idX I www.idxcorporation.com I REQUIRED AT LOCATIONS OF REMOVED AA26000940 SHEET NOTES STOCKROOM DIM: EACH PANEL = 47.71 "H x 47.688"L x 2"D REGISTERS AND FIXTURES. 7. GENERAL CONTRACTOR TO ACCESS PERMIT POTENTIAL INFORMATION FOLDER ON WORKSPACE FOR Ld 1. THE QUANTITIES (COUNT) OF ITEMS PURCHASED STAGING AREAS cn Ln Boa" -'moo FIXTURE ANCHORAGE DETAILS. w w a8H z BY OWNER AS SCHEDULED F I THIS "OWNER 8. GENERAL CONTRACTOR TO INSTALL RAILING PER ° N zw� Z�(nI Q MANUFACTURERS RECOMMENDATIONS AND w ~-�W a>wOO�J LOCATION OF PICKUP �a x~�Q�ow= aNw SUPPLIED MATERIALS AND OWNER SUPPLIED INSTRUCTIONS FOR INSTALLATION AND a �oQ�o N�o AUTOMATED ww 3z i..w Z ANCHORING. aN�razoFc9aFa�o�O ITEMS" SCHEDULES, MAY NOT ACCURATELY EQUIPMENT AREA oi z� w REPRESENT THE ACTUAL QUANTITY REQUIRED TO COMPLETE THE SCOPE OF WORK INCLUDED PREFERRED FORKLIFT 1-- PATH/EQUIPMENT oa-Z��w3oo���z� POWER POLE.. FURNISHED BY 0 3WgBo=oo��WW�o� IN THE CONTRACT DOCUMENTS. ACTUAL OWNER. REF ELECTRICAL c Q Z�'��°1O�-wJ o Z CRATE FINISH LEGEND< �o`�``N='''� vie -0 QUANTITY (COUNT) OF OWNER SUPPLIED ITEMS q q �Zma—zuj o SHALL BE DETERMINED THROUGH A THOROUGH COORDINATE PATH WITH REVIEW AND ACCOUNTING OF THE CONTRACT VENDOR Lno=�wa�ow�az3� DRAWINGS. UPRIGHT TUBE BY VENDOR .46C2" DIA HOLE BY VENDOR LVT1 =vwia0atavwiwalo 0a � r�Ivic.orna��aawoa� 2. REFERENCE APPENDIX A IN THE MATWORKSFAUX D44 SPECIFICATIONS TO DETERMINE WHO IS G.C. TO REFERENCE MARYANNE VITTY RESPONSIBLE FOR THE INSTALLATION OF PLAN VIEW MANUFACTURERS CUT 301-837-1251 PHONE OWNER FURNISHED PRODUCTS. SHEETS FOR NUMBER AND LOCATIONS OF CABINETS. WALMART 2 FLOOR ANCHORS 3 FURNISHED, G.C. INSTALLED FLOOR TUBE RAIL BY VENDOR MAX AUTOMATED 7 POTENTIAL STAGING AREA01 LVT1 TRANSITION STRIP REF 6-A1 EQUIPMENT BY FULL LVT1 EDGE _ m VENDOR _-- --- G.C. TO COORDINATE REQUIRED STAGING LOCATE POWER POLE AT THE TYP - AREA LOCATION WITH STORE MANAGER AT "--------------------------- EXISTING FLOOR TO REMAIN BACK CORNER, BESIDE THE LEAST ONE WEEK PRIOR TO START. 3/8"-16x3" WEDGE CABINET CLOSEST TO THE MTL CART BUMPERS LVT1 LOCATION SHOULD NOT IMPEDE CUSTOMER ANCHOR AT ENDS FLOOR ANCHOR AUTOMATED EQUIPMENT. FLOW OR FIRE EGRESS PATH AND SHALL AND AT EACH THRU BOTTOM MITER CORNER TYP 000 0-❑ BE LARGE ENOUGH TO HOLD (4) PARKED SECTION, DHRILL 1 O /•4". HOLE IN TUBE PALLETS. SECTION A VCT TYP � FLOOR MOUNTING PLAN AND SECTION BUMPER DETAIL CABINET ELEVATION- v 3" = 1'-0" A010-008 � 3" = 1'-0" A010-007 � 1 /2" = 1'-0" STAGING AREA AND DELIVERY PATH LVT TO VCT Qi 9 o � � 1" = 20'-0" 5 6 SALES FLOOR 7 8 FLOOR TRANSITION (_0 5 1/8" = 1'-0" A010-005 O RELOCATED PIZZA, I CHICKEN AND BREAD i i I WARMERS. REF ELEC RELOCATED RELOCATED RELOCATED I O FIXTURES FIXTURES FIXTURES LLJ cc a�-�-d 10'-44 8'-64" 7'-4" 9'-1" 11'-3 11'-1" 11'-0" 7'-0" 6'-5 O C 0 �q I— I 3 7,-0„ 7,-0„ U? oc Al NEW ATTENDANT o 0 0 -j o CQ STATION 1 1 1 1 1 Oa -1 F;� _ a JOIST JOIST 'n od N 6'-5" -1 Ln �� NEW FIXTURES NEW ATTENDANT --------------------� Q�3 w STATION RELOCATED N 2 1 FIXTURES 1'-0" P3001 UNISTRUT c (INSTALL PERPENDICULAR TO 1 1 MAX JOISTS UP TO 45 DEGREES FROM PERPENDICULAR TO JOISTS) 1 1 i i 01 ISSUE BLOCK in 1 1 /2" DIA A36 ROD CLR I O O ZP1064 PLATE WASHER ATTACHMENT BY MONITOR i WITH STD HEX NUT TOP SUPPORT MANUFACTURER AND BOTTOM i 1 OPTIONAL MONITOR MONITOR SUPPORT MONITOR SUPPORT INSTALLED i BULLPEN AND SUPPORT LOCATION OWNER FURNISHED BY GENERAL CONTRACTOR. 1 1 (12) SELF _IN ORB INSTALLED TO SUPPORT 1 CHECKOUTS TO BULLPEN AND (6) SELF r7 BY OWNER (LV CONTRACTOR) 1 BE INSTALLED (2) RELOCATED CHECKOUTS TO BE 1 1 I MANNED INSTALLED 00 1 1 CHECKOUTS 1 1 OVERSIZED ITEMS MONITOR SUPPORT BRACKET 4 3/4" = 1'-0" A010-004 i 1 1 1 1 0 20'-0"0. 1 I FLOOR EXTENTS 1 1 - ❑ ® -� B I 1 1 N� SIN 1 N 1 1 I ------------------------- CHECKED BY: GK (8) SELF -CH CK UTS 3: TO BE INSTA LE DRAWN BY: AMF O EXISTING FIXTURES FILE NAME: A01C o>, ® _ _ METAL CART BUMPERS 19'-8 6'-2" 7'- 6" 17'-82" 6'-34" 9'-OZ" g�_2 9�_4 EXISTING FIXTURES/CHECKOUTS 2 4 PROTO CYCLE: 072718 7 -3" 7 -10 /CHECKOUTS 16'-612'-43' PROVIDED BY OWNER,4TO REMAIN LINO TO REMAIN UNO INSTALLED BY G.C. OUTSIDE EDGE OF DOCUMENT DATE: 09-07-1i? RELOCATION OF EXISTING AND/OR INSTALLATION OF PATCH AND REPAIR FLOOR NEW REGISTERS AND EQUIPMENT 0 BUMPER 3" MAX FROM NEW PREFABRICATED CASH WRAP(S) FOR CHECKOUTS TO MATCH ADJACENT BY OWNER, REF ELECTRICAL (TYP) o EQUIPMENT EDGE. BY WALMART. PRIOR TO RELOCATION AND INSTALLATION 5'-9 5'-94" REF 7-A1 FLOOR PLAN VERIFY FINAL LOCATION WITH STORE PLANNING FIELD a PROJECT MANAGER. GENERAL CONTRACTOR TO CAULK NEW CHECKOUT LAYOUT, BASE AUTOMATED BASE 2 BASE TO FLOOR WHEN LOCATION IS FINALIZED. REF E1 FOR POWER EQUIPMENT BY 1/8" = 1'-0" A010-002 oN VENDOR LZ LOCATE POWER POLE j AT BACK CORNER OF 5 6 7 8 Cn THE CABINET, CLOSEST SALES FLOOR FRONT TO THE AUTOMATED N EQUIPMENT - REF I RELOCATE EXISTING RELOCATE EXISTING i RELOCATE EXISTING i RELOCATE EXISTING i / ELECTRICAL POWER FIXTURE. REFERENCE FLOOR FIXTURE. REFERENCE FLOOR FIXTURE. REFERENCE FLOOR r RECEPT. SHOULD FACE I CHICKEN/PIZZA/BREAD PLAN FOR NEW LOCATION I PLAN FOR NEW LOCATION I PLAN FOR NEW LOCATION F RELOCATE EXISTING WARMERS z g , g C w LOCKERS POWER POLE ' o Q ) FIXTURE. REFERENCE FLOOR m i INSTALLED BY GC PLAN FOR NEW LOCATION A Ix FURNISHED BY OWNER, RELOCATE EXISTING C FIXTURE. REFERENCE FLOOR n o 0 PLAN FOR NEW LOCATION" o LVT1 SUSPENDED OVERSIZED REMOVE EXISTING 11, 0 o ITEMS MONITOR (OIM). FIXTURES SHOWN o ,E- (0 o7 L MOUNT TO 90" CLEAR DASHED ' 'Ram * n Q a � d ABOVE FINISH FLOOR. REF ELECTRICAL. m z REF 4-A1 Q Ella- REMOVE ESEXISTING SHOWN 00 REMOVE EXISTING O � f J 00 ALIGN FACE OF FIXTURES SHOWN o < AUTOMATED7 DASHED DASHED N EQUIPMENT TO 00 FRONT OF STORE o N T Ln a 00 00 \ NXX I O o CABINETS. WALMART > N FURNISHED, GC INSTALLED __ cn o REMOVE EXISTING DOCUMENTS T D i- o G.C. SHALL Q INSTALL OWNER WOOD PLANK ENGINEER OF RECORD HAVE THE ARCHITECT OR EXISTING BULLPEN TO BE FLOORING AND _J o FURNISHED WALL REMOVED. (8) EXISTING PATCH TO MATCH O SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION O PANEL SYSTEM SELF CHECKOUTS TO BE ADJACENT REF 8-A1 REMOVED 0 N _D xy101 c REMOVE ATTENDANT FLOOR m _ STATION IF 6 PLANS m j LVT1 PROVIDED BY OWNER, INSTALLED BY G.C. 0 REF 5-A1 FOR AT EXPOSED PAINTED STRUCTURE OR DECK, NOTE: REF 9-A1 ® B o ° TRANSITION PAINT NEW CONDUIT, DUCTWORK AND FIRE FOR STAGING AREA E SPRINKLER PIPING (FIRE SPRINKLER HEADS EXISTING FIXTURES 00 � TO REMAIN UNPAINTED) TO MATCH (8) EXISTING 6 EXISTING o ADJACENT STRUCTURE OR DECK (2) EXISTING (2) EXISTING EXISTING FIXTURES/CHECKOUTS /CHECKOUTS ( ) N MANNED CHECKOUTS MANNED CHECKOUTS MANNED CHECKOUTS MANNED CHECKOUTS `n SINGLE STACK -CHECK I N FLOOR PLAN TO BE REMOVED TO BE RELOCATED TO BE REMOVED TO REMAIN UNO TO REMAIN UNO TO BE REMOVED �o rn a 3 1,4" =1'-° A010-003 DEMOLITION PLAN a � SHEET: wN Al j 1/8" = 1'-O" A010-001 — - -- -- - _ 0 U) 0 c 0 v m a) w :2i Ip a- 0 � N 00 U) O N >, "Q a7 N o� W nl > I Q co U) 0 r` �- o Q� �OC) 0 O 06 �o O N 0 o � m v 0 0 CD E DO �9: 0 /v, N Ln \ U N \ O Q o � W N Z Q ATTACH TO THE 6 MIL CLEAR POLY SHEETING BOTTOM OF JOISTS OVERLAPPED AT JOINTS A MINIMUM OF 1'-0" AND CONTINUOUSLY TAPED JOINTS. ATTACH SHEETING FROM THE BOTTOM OF JOIST TO FINISHED FLOOR FOR A DUST PROOF CONDITION. 6 MIL POLY SEAL TIGHT AT THE BOTTOM OF PARTITION 104'-0" HORIZONTAL 1 /2" CD PLYWOOD 4'x8' 2x4 WOOD FRAME ::�--AT 8'-0" OC SANDBAG OR SIM TO RESTRAIN MOVEMENT DO NOT ANCHOR OR ADHERE TO FLOOR IN ANY MANNER TEMPORARY DUST PARTITION 2 3/4" = 1'-0" A010-012 SALES FLOOR 5 6 7 8 GRID WALL FURNISHED BY WALMART AND INSTALLED BY GC. REFERENCE MANUFACTURERS 19'-10>' 9'-11 1 ' INSTALLATION MANUAL. GRID WALL FURNISHED BY WALMART AND INSTALLED BY GC. REFERENCE MANUFACTURERS INSTALLATION MANUAL. 11'-84„ 16'-0„ o LO N " � I � GRID WALL FURNISHED BY 1 � I WALMART AND INSTALLED fU BY GC. REFERENCE MANUFACTURERS INSTALLATION MANUAL. —IN ro 1 ❑ ❑ ❑ 2'-3„ 16'-5" 11'-34,> 1,- - B Ln 1'- '4'-10" 7'-6" 17'-7" 0. GRID WALL FURNISHED BY WALMART AND INSTALLED BY GC. REFERENCE MANUFACTURERS INSTALLATION MANUAL. GRID WALL PLAN VERIFY PLACEMENT OF EXISTING 1 REGISTERS. NOTIFY CONSTRUCTION 1 /8" = 1'-0" A0107002 MANAGER IF END OF REGISTERS WILL NOT ALIGN WITH FACE OF GRID WALL AS SHOWN. p+enb2 hitecture gineering 2809 Ajax Avenue Suite 100 Rogers Arkansas 72758 Phone: 479.636.3545 Fax: 479.636.1209 Architect of Record William Douglas Hurley Florida License No. AR91919 Architect Business Lic No. AA26000940 w w 4 0 Ld 20QU) O T1 zw OwtN,Twz w z U H Q� W 0 ( 0tiX <5; t50-Zli L"W zwtz z� a Q 2- 0 Q X O w= z Q N w a— 0Qow�Uoz�r 0 Q JwwF00 t� a�4pJQO-zm-QUwFo U-NOD Q-Q nowD 0 3U-jwnOpmwwzmwrQ J O w ow ~ zow<00�-o OUP0Zz JQd0pw�FU�}��tn0 OOWJu UE MUiOwwwz�wm X ui<- w�a3-, f V)wazrt:OwL 0005<0 in H 0 N UU 0 V01 d 0 M a d w on M. E- W cm O O � O w co 0 O O U)CC) N z 0 CHECKED BY: DID DRAWN BY: AMR FILE NAME: A010 PROTO CYCLE: 072718 DOCUMENT DATE: 09-07-18 DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION GRID WALL PLAN SHEET: A1.1 14 W 0 I c 00 E Q U 0 m E U Q 0 Q0 0 � o 0- 00 a) 0 j N \ 0, O \ o 0 0 � W cQ00 n �0 v N Q W W (D 0 EQ) 6 N -a Q O N � I CO � Co a O N I' 00 O 00 C6 O O N N O � M 0 0 — LLJ E z, 1" TEE WITH PLUG SUPPLY FROM WET PIPE SPRINKLER SYSTEM INSTITUTIONAL MODEL FLEXHEAD SPRINKLER DROP FIRE PROTECTION CORRUGATED CONTRACTOR SHALL INSTALL STAINLESS STEEL HOSE PIPE THROUGH HOLE WITH STAINLESS STEEL RESERVED FOR SPRINKLER BRAID 4' LENGTH. INSTALLATION. WALL PLATE NOTE TO CONTRACTOR: DO NOT ATTACH TO UNIT PROVIDE A SIGN WITH THE FOLLOWING STATEMENT AND ATTACH TO THE TOP OF THE ADJUSTABLE HUB MULTI -PORT BRACKET AUTOMATED EQUIPMENT. INSTALL AS LOW AS POSSIBLE FLEXIBLE DROP IS METAL STUD (OR APPROPRIATE PRESSURIZED. PRIOR TO REMOVING FIRE SPRINKLER RIGID SURFACE). DRAIN FIRE PROTECTION SYSTEM AND 1" DROP" SELF TAPPING AUTOMATED EQUIPMENT SCREWS _ PANEL (ROOF) 1" MAX. PENDENT SPRINKLER NO ESCUTHEON REQUIRED PENDENT SPRINKLER WITH FLEXIBLE PIPING NTS PIPE TABLE (WET) --•! NOMINAL! PIPE SIZE DIAMETER �-- —VIP! MOM ! •� i���--- SCHEDULEm SCHEDUL mass 1• • L all PIPE SIZES SHOWN ARE FOR HYDRAULIC CALCULATIONS PURPOSES ONLY. REFER TO SPECIFICATIONS FOR ALLOWABLE SUBSTITUTIONS. PIPE DIMENSION TABLE NTS IN LANE TOWER FIRE PROTECTION PLAN NTS 0 4' 8' 12' SCALE: 1 /8"=V-0" p+enb2 hitecture gineering 2809 Ajax Avenue Suite 100 Rogers Arkansas 72758 Phone: 479.636.3545 Fax: 479.636.1209 Engineer of Record Joshua D. McCall, P.E. Florida License No. 79905 COA License No_ 26880 Li Li w t,i SoON wo N Z Z U N_? 3 W O �_ Nwo: a>O w w 0 o QQ 2'~t, OQ Ow=Z QMP Nw wr �ZQJOw 002Z57H p a -w0-.00 LLaNp>QZOr-Zg�Qjw�rO Coon O 3VdaN50ORwwZa'wrQ w z0 oa:5ww�0W ~ zvaiIFQrno�v_>o0S:- zI J3 Jo off, N---cwi�rNwv_r0 D Z= m o I U.w w U Of w Z U w w oOx�LLJ Wj�LLJ Nwaz �LowL,00CDQO} Lo IDrNOOV=ian�aawoa� E— W Gs. yo O 0 �--� CD � O W O 0 0 CQ w N z m 0 CHECKED BY: JDM DRAWN BY: ANJ mm PROTO CYCLE: 072718 DOCUMENT DATE: 09-07-18 o>, II I11/�� NO, ?ggps N STArEOF .7 2018 DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION FIRE PROTECTION PLANS SHEET: FP1 ELECTRICAL SYMBOLS LEGEND 10.28.16 (SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) ES06 SYMBOL DESCRIPTION Fo/LIGHT 0 FIXTURE (WALL MOUNTED/CEILING MOUNTED) LIGHT FIXTURE LIGHT FIXTURE EMERGENCY LIGHT LIGHT FIXTURE NIGHT LIGHT 0 ENCLOSED COOLER/FREEZER LIGHT -E) e TRACK LIGHTING /® EXIT FIXTURE (WALL MOUNTED/CEILING MOUNTED) 17p EMERGENCY FIXTURE SWITCH, SINGLE POLE $3 SWITCH, 3-WAY $4 SWITCH, 4-WAY $K SWITCH, KEYED ! PROVIDE 3/8" FLEXIBLE METAL WHIPS FROM JUNCTION BOX AND CONNECT AT TOP OF POWER POLE. CABLE WHIPS TO POWER POLE SHALL BE INSTALLED IN A NEAT AND WORKMAN -LIKE MANNER. ROUTE WHIPS TO TERMINATIONS ALONG UNISTRUT OR STRUCTURE AND SUPPORT EVERY 12" TO 24". EXCESS CABLE SHALL BE KEPT TO A MINIMUM AND TIGHTLY COILED AND ATTACHED TO UNISTRUT OR JOIST. NO CONNECTION OF ANY KIND SHALL BE MADE TO JOIST WEB MEMBERS, JOIST BRIDGING, OR ROOF DECK. MAINTAIN MINIMUM 6" CLEARANCE FROM TOP OF POWER POLE TO ROOF DECK. JUNCTION BOXES AND RACEWAYS SHALL NOT BE MOUNTED WITHIN 1-1/2" OF DECK. EXTEND POWER POLE 12" MIN. WITHIN PVC SLEEVE-\ 2-1/2" UNISTRUT $D SWITCH, DIMMER STRAP FIRMLY CLAMPED TO CONDUIT $VS SWITCH, VARIBLE SPEED $M SWITCH, MANUAL MOTOR $0S SWITCH, OCCUPANCY SENSOR $$0S SWITCH, BI-LEVEL OCCUPANCY SENSOR ES / ® CEILING OCCUPANCY SENSOR AND ASSOCIATED RELAY 2-1/2' PVC CONDUIT RECEPTACLE, DUPLEX RECEPTACLE, DUPLEX, MOUNTED HORIZONTALLY RECEPTACLE, DOUBLE DUPLEX 1`f RECEPTACLE, DUPLEX ISOLATED GROUND RECEPTACLE, DOUBLE DUPLEX, ISOLATED GROUND RECEPTACLE, SIMPLEX TWIST LOCK, �J L5-15R, UNO RECEPTACLE, SIMPLEX TWIST LOCK, l�J ISOLATED GROUND, L5-15R, UNO n RECEPTACLE, DUPLEX TWIST LOCK, L5-15R, UNO POWER POLE PVC SLEEVE LENGTH 12" MIN. TO 36" MAX. TO ACCOMMODATE VARIATIONS IN STRUCTURE HEIGHT. INSTALL CEILING FLANGE PROVIDED WITH POLE FOR STORES WITH LAY -IN CEILING ANCHOR POWER POLE TO FLOOR OR GONDOLA WITH FOOT BRACKET PER MANUFACTURER RECOMMENDATIONS UNISTRUT PROVIDE UNISTRUT PER SPECIFICATIONS. LENGTH AS REQUIRED TO SPAN JOISTS. SECURE TO TOP OF BOTTOM CHORD OF BAR JOIST. PROVIDE 1 /4" BOLT AND 1-1/4" FENDER WASHER, TYP PROVIDE UNISTRUT P1026 ANGLE FITTING OR EQUAL PROVIDE 1-1/4" BOTTOM FENDER WASHER, LOCK CHORD OF WASHER AND NUT, TYP BAR JOIST FINISHED FLOOR POWER POLE CONNECTION NTS 01-29-18 EP42 RECEPTACLE, DUPLEX TWIST LOCK, IF NEW CIRCUIT SHOWN IS NOT AN AVAILABLE lAl ISOLATED GROUND, L5-15R, UNO SPACE IN PANELBOARD, USE ANOTHER AVAILABLE SPACE IN THE SPECIFIED PANELBOARD, OR IF RECEPTACLE, SPECIAL NECESSARY, FED THE NEW CIRCUIT FROM ADJACENT OR NEAREST AVAILABLE PANELBOARD ADJUST LIGHTING AS RECEPTACLE, SIMPLEX WITH CIRCUIT BREAKER SHOWN. REQUIRED FOR NEW PICKUP TOWER. RECEPTACLE, PLUG -MOLD O JUNCTION BOX (WALL MOUNTED/CEILING MOUNTED) A O JUNCTION BOX, ALARM SYSTEM (WALL MOUNTED/CEILING MOUNTED) ALARM JUNCTION BOX, ® FOR REMOTE TEST/RESET (WALL MOUNTED/CEILING MOUNTED) EQUIPMENT CONNECTION POINT (PROVIDED WITH EQUIPMENT) Eh NON -FUSED DISCONNECT 01 FUSED DISCONNECT SWITCHED/ TRAVELERS NEUTRAL CIRCUIT, CONCEALED IN WALLS OR CEILING, E INDICATES EXISTING Ic HOTS GROUND WIRING CIRCUIT, CONCEALED IN FLOOR SLAB, -'` _ _h+ E INDICATES EXISTING WIRING CIRCUIT, EXPOSED, E INDICATES EXISTING WIRING FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED PANELBOARD VOICE/DATA, -/-/- d v d = DATA ONLY, v = VOICE ONLY Q LOW VOLTAGE CABLE BOX FOR OTHER VOICE/DATA, FLUSH FLOOR MOTOR QO TELEPOWER POLE 4 Q PUSH BUTTON u` BUZZER 0 0 OS SMOKE DETECTOR I ENERGY MANAGEMENT U O TEMPERATURE SENSOR 0 30A DISCONNECT MOUNTED AT STRUCTURE. REFERENCE EXISTING CHLICKOUTS MANUFACTURER'S REMOVED C16.492 INFORMATION FOR MOUNTING LOCATION AND REQUIREMENTS. FACTORY INST D € JUNCTION DX FINAL CONNE TI S MADE BY .C. mm`I fib- 4 AUTOMATE J(16.42 I EQUIPMENT-(20A 6' 1" AUTOMATED I GENERAL POWER NOTES 11,20.15 EN02 20A WIRE SIZING SCHEDULE GENERAL NOTES 10.28.16 ENO8 1. TELEPOWER POLE(S): MOUNT JUNCTION BOX(ES) TO TOP ALL WIRE SIZES SHOWN ON PANEL SCHEDULES ARE 1. FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND SIDE OF BOTTOM CHORD OF BAR JOIST. INSTALL INTENDED TO BE MINIMUM ACCEPTABLE WIRE SIZE. LABOR, FOR A COMPLETE INSTALLATION IN ALL RESPECTS, 2 FURNISHED PRE -WIRED POWER POLE AND TERMINATE THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH PROVIDED FLEXIBLE CONDUIT AND WIRING TO JUNCTION WIRE FOR AMP CIRCUITS (120 AND 277 VOLT). NEC, NESC, STATE, AND LOCAL CODES, AND MANUFACTURER'S BOX. PROVIDE UNISTRUT SUPPORTS AND HARDWARE TO LENGTHS {IN N FEET) ARE INTENDED TO BE MAXIMUM. RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS. architecture SECURE TELEPOWER POLE PLUMB TO BUILDING A NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS +engineering STRUCTURE. 2. PROVIDE LIQUID -TIGHT FLEXIBLE METAL CONDUIT AND WIRING FROM DISCONNECT SWITCH OR JUNCTION BOX TO 3" X 3" 1 /4" ANGLE BETWEEN EQUIPMENT KNOCKOUT OR ELECTRICAL CONNECTION BAR JOISTS AT PANEL POINTS. POINT. THE ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR WALLS. 2809 Ajax Avenue Suite 100 Rogers Arkansas 72758 B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE. Phone:479.636.3545 Fax: 479.636.1209 C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE J-BOX SECURED TO 3. WHERE EQUIPMENT NAMEPLATE PROTECTIVE DEVICE OPERATIONS. COORDINATE ALL DISRUPTIONS WITH Engineer of Record BAR JOIST OR RATING DIFFERS FROM SIZE PROVIDED, CHANGE OUT BRIDGING. BRANCH CIRCUIT WIRING AND OVERCURRENT DEVICE TO APPROPRIATE RATING PER NEC. 4. ELECTRONIC FIRE PROTECTION/SECURITY ALARM BOXES 120 VOLT #12 #10 #8 #6 1-5 AMPS 200 FT. 325 FT. 490 FT. 770 FT. 6-10 AMPS 100 FT. 160 FT. 245 FT. 385 FT. 11-15 AMPS 70 FT. 110 FT. 165 FT. 255 FT. 277 VOLT #12 #10 #8 #6 1-5 AMPS 480 FT. 760 FT. 1170 FT. 1865 FT. 6-10 AMPS 240 FT. 380 FT. 585 FT. 930 FT. 11-15 AMPS 160 FT. 250 FT. 390 FT. 620 FT. WALMART CONSTRUCTION MANAGER AND STORE MANAGER. Keith A. Williams, P.E. Florida License No. 64983 D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESSES COA License No. 26880 BEFORE INSTALLING BOXES. FURNISH AND INSTALL EXTENDED BOXES OR BOX EXTENDERS WHERE REQUIRED. JUL AND CONDUITS SHOWN ON POWER PLANS SHALL BE PROVIDED UNDER THIS CONTRACT. IN ADDITION, UNLESS NOTED OTHERWISE, THE FOLLOWING GENERAL NOTES APPLY: 20A WIRE SIZING SCHEDULE APPLIES TO EVERY SHEET WITH PANELBOARD SCHEDULES E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS PROPERLY COVERED AND THAT ALL TRIM IS IN GOOD CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. w ww� cwn Npzp 2oa`�Wo � o Nz�� oW��wz wOf oaa Qa F-Ei<w6ww-Z<Nw A. ALL ALARM JUNCTION BOXES SHALL BE PANELBOARD NOTES 2. PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: o wN<3zzacwaa`�aozo°o (n r "KELLEMS" STRAIN 4"X4"X2-1/8" MINIMUM. A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE z (n2 V)�N<QXW RELIEF CONTAINMENT B. ALARM RACEWAYS SHALL BE 3/4" MINIMUM WITH STOPPING. oa+Wi-No�Q� O �,V.) w-zaWra 1. E.C. SHALL ADD OR REARRANGE CIRCUIT BREAKERS-�� GRIP PULL WIRE AND INSULATING BUSHINGS AT END OF B. NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL. � oa Qov���ZiY Q zN <*0P n H 6zz `� cnxww Nw_ VERTICAL RACEWAY RUN. WITHIN PANELBOARDS AS REQUIRED TO MATCH C. FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM -I aaiazw��z��Wc��" wzqEM owoU wc. ww0' _w Op=r C. VERTICAL RACEWAYS FROM ALARM BOXES SHALL BE NEW CIRCUIT DESIGNATIONS SHOWN ON DRAWINGS. SEALANT. ¢UJ0Of_ z, �m �waz�'�owwooc�ao} SO CORD AS SPECIFIED EITHER CONCEALED INSIDE WALL OR SURFACE D. EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR U) ��`ni�ov=ia��a. wwzw � FOR EQUIPMENT. MOUNTED (TO MATCH JUNCTION BOX MOUNTING). ALL 2. NEW OVERCURRENT PROTECTIVE DEVICES PLACED IN SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED VERTICAL RUNS SHALL BE TURNED 90-DEGREES AT EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHALL DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY CONNECTOR AS TOP SIDE OF BOTTOM CHORD OF BAR JOIST AND MATCH THE TYPE AND AIC RATING OF EXISTING PENETRATIONS. SPECIFIED FOR EXTENDED HORIZONTALLY TO A LOCATION ACCESSIBLE OVERCURRENT PROTECTION DEVICES IN SAID BOARD. 3. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR EQUIPMENT. BY VERTICAL FLOOR TYPE LIFT. 3. E.C. SHALL TRACE ALL ELECTRICAL CIRCUITS FOR ALL (SIZE PER NEC) IN PVC TYPE CONDUIT, POWER CIRCUITS, SUSPENDEDPOWER DROP 5. UPON COMPLETION OF ELECTRICAL INSTALLATION AND PRIOR TO ENERGIZING CIRCUIT: EXISTING ELECTRICAL PANELBOARDS AFFECTED BY THE REMODEL AND IDENTIFY LOADS ON EACH CIRCUIT. ISOLATED GROUND CIRCUITS, OR AS SHOWN ON PLANS. CONDUIT SHALL BE SIZED PER NEC BASED ON THWN 600 A. INSPECT WIRE AND CABLE FOR PHYSICAL DAMAGE. PROVIDE A COMPLETE TYPEWRITTEN PANELBOARD VOLT COPPER SINGLE CONDUCTORS, PLUS THE EQUIPMENT DETAIL 0 P E N T 0 ST RU C TU RE B. PERFORM CONTINUITY TEST. IDENTIFICATION SCHEDULE FOR ALL AFFECTED GROUNDING CONDUCTOR. PANELBOARDS. 4. WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM NTS 07.26.13 VERIFY NUMBER OF BEVERAGE COOLERS ON FINAL MERCHANDISE PLAN. LOAD ON CIRCUITS SHALL NOT EXCEED 15 AMPS INCLUDING CHECKOUT LOAD. IF QUANTITY SHOWN EXCEEDS THIS ALLOTMENT, FURNISH AND INSTALL ADDITIONAL CIRCUITS AS REQUIRED AND SIZE CONDUCTORS FOR LOAD AND VOLTAGE DROP. REFER TO THE 20A WIRE SIZING SCHEDULE ON SHEET E1. REMOVED 16.492 PLUG IN ALL COOLERS TO NEAREST POWER POLE. NO MORE THAN TWO COOLERS ARE PERMITTED TO CONNECT TO A SINGLE POWER POLE. JLY CHECKSTAND POWER POLES DESIGNATED AS "UP SHALL BE CONNECTED TO A UPS CIRCUIT. NO CHECKSTAND BELTS OR COOLERS ARE PERMITTED TO CONNECT TO UPS POWER. RE -USE EXISTING CIRCUITS FOR THE CHECKOUTS THAT ARE TO BE DEMOLISHED, BEFORE ADDING NEW CIRCUITS. PROVIDE LISTED HANDLE -TIE BETWEEN CIRCUIT BREAKERS SHARING COMMON NEUTRAL FOR SIMULTANEOUS TRIP. L4D3-1 WREP24 C. VERIFY PROPER PHASING CONNECTION TO ALL THREE FINISHED FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED PHASE MOTOR LOADS. 4. ALL OVERCURRENT DEVICES ARE NEW UNLESS NOTED OTHERWISE ON PLANS. COORDINATE THE STANDARD OTHERWISE. MOUNTING HEIGHTS WITH MASONRY: 6. REPLACE ANY MISSING, DAMAGED OR BROKEN A. SWITCHES RECEPTACLES AND COVER PLATES THROUGHOUT THE B. RECEPTACLEESS INTERIOR AND EXTERIOR OF THE STORE. C. VOICE/DATA 20" POWER DROP SCHEDULE 5. WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT E, GROUND WIRE SIZING CHART 07.28.17 ES01 IN CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING DIAGRAMS. BREAKER NO. DESCRIPTION 6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE 0 O AMPAY WIRE WIRE SIZE PANELBOARD IDENTIFICATION SCHEDULES FOR PANELBOARDS IF NEW CIRCUIT SHOWN I MOUNT RECEPTACLE(S) ON TOP OF AFFECTED BY REMODEL. O c9 SPACE IN PANELBOARD, USE ANOTHER VAII A PHASE #12 #10 #8 #6 #4 PD1 DISPLAY UNIT(S) 7. NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN ~� N MOUNT RECEPTACLE(S) 6" ABOVE BASE OF DISPLAY SPACE IN THE SPECIFIED PANELBOARD OI I GROUND #12 #10 #8 #6 #4 OR DISTRIBUTION BOARDS SHALL O NECESSARY, FED THE NEW CIRCUIT PHASE #10 #8 #6 #4 #3 PD2 EXISTING PANELBOARDS Q ADJACENT OR NEAREST AVAILABLE PAN L�BAI� UNITS) SO THAT RECEPTACLE(S) AND CONDUIT DO NOT MATCH THE TYPE AND AIC RATING OF EXISTING OVERCURRENT WITH CIRCUIT BREAKER SHOWN. GROUND #10 #8 #6 #4 #3 INTERFERE WITH SHELF HEIGHT ADJUSTMENTS PROTECTIVE DEVICES. O PD3 PROVIDE DIRECT CONNECTION TO PHASE #8 #6 #4 #3 #2 35-50 8. BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG 0 GROUND #10 #8 #4 #4 #4 EQUIPMENT UNLESS NOTED OTHERWISE IN SCHEDULES WHERE 20A .. EXISTING TELEPOWER POLES SHALL BE SECURED SIMILAR TO DETAIL 6-E1 WITH OPTION OF UTILIZING 2-1/2" RIGID PVC SPLIT DUCT TYPE SLEEVE FROM PRIME CONDUIT MWE INC, VIKIMATIC OR INNERDUCT. COORDINATE WORK WITH WALMART STORE MANAGER AND CONSTRUCTION MANAGER TO MINIMIZE DISRUPTIONS TO STORE OPERATION AND ANY EQUIPMENT SERVED BY EACH POWER POLE. r I20'-9" 4- 1- L- • •A PREIs _.. - I 26 i 16.414 L1ID2 L3U5 - OVERSIZED 1 .470 ITEMS MONITO i� J 16.0 2 6 00 L4D3-16 UPS E1 TYP 25'-3" a IN -LANE TOWER POWER 1/8,, = 1'-0" JLY CHECKSTAND POWER POLES DESIGNATED AS "UP SHALL BE CONNECTED TO A UPS CIRCUIT. NO CHECKSTAND BELTS OR COOLERS ARE PERMITTED TO CONNECT TO UPS POWER. 71 N A 191TAMPILlm• 16.957 I_ I J L4D2- 30 _ L4D3-16 16.4 0 16.957 .0 2 - � I I r L3U-119 J 16.4 1 I L4D3-10 16.0 2 PLAN I UPS L3U-19 L4D2-28 d 16.957 16 4-71 16.470 - E010-004 '` _ J - _ - 16.032 16.032 - i I N UPS IF NEW IR UISHOWN IS NOT AN AVAILABLE J SPACE IN PANELBOARD, USE ANOTHER AVAILABLE SPACE IN THE SPECIFIED PANELBOARD, OR IF L4D3-10 L4D2-30 J L4D3-4 01 NECESSARY, FED THE NEW CIRCUIT FROM C16,957 16.470 16.957 ADJACENT OR NEAREST AVAILABLE PANELBOARD 16.032 WITH CIRCUIT BREAKER SHOWN. �,'-a" 7'-a" 7'-11" o ° OT THERMOSTAT EXISTING TELEPOWER POLES SHALL BE SECURED SIMILAR TO DETAIL 6-E1 WITH OPTION OF UTILIZING 2-1/2" RIGID PVC SPLIT DUCT TYPE SLEEVE FROM PRIME CONDUIT MWE INC, VIKIMATIC OR TC TIME CLOCK INNERDUCT. COORDINATE WORK WITH WALMART STORE MANAGER AND CONSTRUCTION MANAGER TO MINIMIZE DISRUPTIONS TO STORE ABBREVIATIONS OPERATION AND ANY EQUIPMENT SERVED BY EACH POWER POLE. b LOWER CASE LETTERS INDICATE HD a, c HAND DRYER SWITCHING CONFIGURATION IG ISOLATED GROUND o AFC ABOVE FINISH COUNTER IRC INTER -REGISTER AFF ABOVE FINISH FLOOR COMMUNICATION jAFG ABOVE FINISH GRADE ISP IN-STORE PROCESSOR C CONDUIT LCU LIGHTING CONTROL UNIT CCT CIRCUIT K KEY OPERATED >, = CF CEILING/CIRCULATION FAN N NEUTRAL V' DATA NTS NOT TO SCALE EEC ELECTRICAL CONTRACTOR P WITH PILOT LIGHT m EF EXHAUST FAN RH RADIANT HEATER / EP EXPLOSION PROOF RC REFRIGERATION o ETR EXISTING TO REMAIN CONTRACTOR a ° EWC ELECTRIC WATER COOLER SC SECURITY CAMERA ° FUT FUTURE SF SUPPLY FAN-� GR GROUND TR TAMPER RESISTANT I Q GFEP GROUND FAULT EQUIPMENT TYP TYPICAL � 0PROTECTION WH WATER HEATER B.4 1 N I GFI GROUND FAULT CIRCUIT WP WEATHERPROOF INTERRUPTER WR WEATHER RESISTANT �r .E- GF GABLE FAN UH UNIT HEATER i I Q UNO UNLESS NOTED a OTHERWISE o w > 2 Q co oO ALL TELEPOWER POLES ARE v oN OWNER FURNISHED AND I j J CONTRACTOR INSTALLED. 1 1 i 1 i I 1 u7 E EACH SUBCONTRACTOR IS RESPONSIBLE FOR n HAVING A THOROUGH KNOWLEDGE OF ALL N DRAWINGS AND SPECIFICATIONS IN THEIR RELATED 1 1 0 � FIELD. THE FAILURE TO ACQUAINT THEMSELVES 1 1 r N WITH THIS KNOWLEDGE DOES NOT RELIEVE THE m ro RESPONSIBILITY OF PERFORMING THE WORK 1 1 a, L3D2- o PROPERLY. NO ADDITIONAL COMPENSATION SHALL I Q o BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR i i 16.4 N DUE TO FAILURE TO FAMILIARIZE WORKERS WITH B r o THIS KNOWLEDGE. TYPICAL OF ALL ELECTRICAL � SHEETS. 00 o EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL o N DRAWINGS AND MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL o = CAREFULLY COORDINATE NEW WORK AND L E DEMOLITION WITH ALL OTHER DISCIPLINES AND z EXISTING CONDITIONS. TYPICAL OF ALL ELECTRICAL SHEETS. L3U-16 S ----- ---------------I 1 OVIDE LISTED HANDLE -TIE BETWEEN CIRCUIT BREAKE >HARING COMMON NEUTRAL FOR SIMULTANEOUS TRIP, PLUG IN ALL COOLERS TO NEAREST POWER POLE. NO MORE THAN TWO COOLERS ARE PERMITTED TO CONNECT TO A SINGLE POWER POLE. RE -USE EXISTING CIRCUITS FOR THE CHECKOUTS THAT ARE TO BE DEMOLISHED, BEFORE ADDING NEW CIRCUITS. VERIFY NUMBER OF BEVERAGE COOLERS ON FINAL MERCHANDISE PLAN. LOAD ON CIRCUITS SHALL NOT EXCEED 15 AMPS INCLUDING CHECKOUT LOAD. IF QUANTITY SHOWN EXCEEDS THIS ALLOTMENT, FURNISH AND INSTALL ADDITIONAL CIRCUITS AS REQUIRED AND SIZE CONDUCTORS FOR LOAD AND VOLTAGE DROP. REFER TO THE 20A WIRE SIZING SCHEDULE ON SHEET E1. /000� CHECKOUT POWER PLAN i I -V, I 7'-0" 14'-7" 9'-6" 1 L3D1-38 L3U-12 16.470 16. 71 #1 ow g j - P-S--- I ATTENDANT 16.470 o STATION ow _ I J q1 `n I ii L D -6 82 CI RCUIT A e .957 L3U-12 6.W04 SAME RICAL I .032 16.471 16.032 CI CUIT A CIRCUI C�9M 4 I L3D 1 L3D1-6 16.957 6.W04 J 7: 116. 5 6 16.032 TYP E1 ' �L16. 51 L3U-14 EXISTING CIRCUITS 2'- 5 16.492 CHECKOUTS IN THIS 7 AREA TO REMAIN. CHECKOUT POWER PLAN 2 1 /8" = 1'-0" E010-002 EXISTING - PANEL L4D2 1 /8" = 1'-0" PHASE #6 #4 #3 #2 #1 PD4 OPEN STRUCTURE: MOUNT RECEPTACLE AT BAR JOIST BRANCH CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 �j"� 0 60 AND INSTALL FURNISHED CORD REEL AWG WIRE SHALL BE USED FOR THE FINAL CONNECTION �+v z GROUND #10 #6 #6 #4 #4 (15-FT MAXIMUM). PHASE #6 #4 #3 #2 #1 W 70 LAY -IN CEILING: PROVIDE RECESSED CEILING RECEPTACLE AND INSTALL FURNISHED CORD REEL 9, WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND ►�4co GROUND #8 #4 #4 #3 #2 DERATE CURRENT CARRYING CONDUCTORS PER NEC. �-�--q O 0 PHASE #4 #3 #2 #1 #1 BELOW CEILING. CORD REEL SHALL BE MOUNTED TO Q 1 80-90 GROUND #8 #6 #4 #4 #3 CEILING FAN RATED JUNCTION BOX SECURED TO LAY -IN 10. PROVIDE UL LISTED HANDLE TIES ON ALL MULTIWIRE BRANCH °D HICKEN WARMER CEILING WITH T-BAR BOX HANGER. PROVIDE 1/2" CIRCUITS PER NEC REQUIREMENTS. 16.489 _ 100 PHASE #3 #2 #1 #1/0 #2/0 THREADED STEEL ROD FROM JUNCTION BOX TO BOTTOM PIZZA WARMER 806 / GROUND #8 #6 #4 #4 #3 OF STRUCTURAL JOIST -OR CHANNEL STRUT BRIDGING 11. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE w ( SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. PD4 ® WIRE SIZES PER NEC 250.122 B ABOVE FOR SUPPORT. 5 UTILIZE ONLY THE TOP AND BOTTOM CHORDS FOR W E1 8O AI SUPPORTING THE ELECTRICAL SYSTEM INSTALLATIONS. N Z I i KEYNOTES 12• DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE SURFACE MOUNTED UNLESS NOTED OTHERWISE. REFER TO o N ARCHITECTURAL DOCUMENTS FOR CONDUIT INSTALLATION AND ~' 13'-6" L - J un SEALING REQUIREMENTS. PS I 16.032 CONNECT CIRCUIT TO POWER POLE WHIP WIRED TO ORANGE TWIST -LOCK 13. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM L3U-5 RECEPTACLES. AND BRANCH CIRCUITS NOTED BY LEGEND SHALL BE 16.957 16.414 MOUNT JUNCTION BOX AT STRUCTURE. INSTALLED UNDER SLAB. ALL OTHER FEEDER AND BRANCH 16.032 - AFTER INSTALLATION OF DROP POLE AND CIRCUITS SHALL BE INSTALLED OVERHEAD. PROVIDE EXTERIOR TV COMPARTMENT TRAY, EXTEND COATED GRC BENDS ON ALL CONDUIT RUNS THAT HAVE 45 1 ° DEGREE BENDS OR GREATER. REF SPECIFICATIONS. o CONDUCTORS IN 1/2" FLEXIBLE METAL CONDUIT ROUTED WITHIN DROP POLE TO 14. SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION COUPLINGS I TV COMPARTMENT TRAY TO MAINTAIN NEC AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY REQUIRED SEPARATION OF POWER AND LOCAL CODES. ® - DATA. PROVIDE 120V, 20A DUPLEX RECEPTACLE AND FINAL TERMINATION AT 15. EXISTING ELECTRICAL AND ALARM: 94D3-8 TV COMPONENT TRAY. A. WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS 16.470 FURNISH AND INSTALL NEW 20 AMP, EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING 1 6.957 o 120 VOLT CIRCUIT(S). FEED FROM EQUIPMENT, DEVICES, OR LIGHTING TO REMAIN, BUT NOT I PANELBOARD AS INDICATED. PROVIDE SHOWN ON DRAWINGS, PROVIDE LABOR AND MATERIALS TO 1 4D3-810 REWORK CIRCUITRY, AS REQUIRED, TO MAINTAIN EXISTING 6 957 20A-1 P CIRCUIT BREAKER, IF NEEDED. OPERATION. l E.C. SHALL MATCH TYPE AND AIC J L3D2 L3D2- L3U-15 RATINGS OF EXISTING CIRCUIT BREAKERS. B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT L3D2- 8 16.471 E.C. SHALL VERIFY PRIOR TO ROUGH -IN EXISTING UNDERGROUND SERVICES (ELECTRICAL, 1 #8 0 16.47 PS 1 #8W P 16.032 THAT EXISTING PANELBOARD HAS SPARE TELEPHONE, PARKING LOT LIGHTING CIRCUITRY, ETC.) J L4D2-18 #1 owriwl CAPACITY TO ACCOMMODATE ADDITIONAL PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO 3U-17 LOAD. REROUTE, SLEEVE, OR OTHERWISE REWORK THESE SERVICES 16.470 16.471 TO MAINTAIN THEIR EXISTING OPERATION. J 16.032 16.032 16.471 FURNISH AND INSTALL NEW 20 AMP, L4D3- �120 VOLT ISOLATED GROUND CIRCUIT(S). C. EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM CHECKED BY: KAW 16.957 I FEED FROM PANELBOARD AS INDICATED. AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO 1 N PROVIDE 20A-1P CIRCUIT BREAKER, IF THAT SYSTEMS REMAIN OPERATIONAL AT ALL TIMES. DRAWN BY: TM 1 4D3-2 NEEDED. E.C. SHALL MATCH TYPE AND " 16.957 2-42 AIC RATINGS OF EXISTING CIRCUIT D. DISPOSE OF ALL REMOVED MATERIALS, UNLESS OTHERWISE PROTO: J I BREAKERS. PROVIDE ORANGE COVER NOTED. _ _ ew•Q - _ .470 PLATES ON ALL ISOLATED GROUND 16. EXISTING ELECTRICAL DEMOLITION: PROTO CYCLE: 072718 r L3U-17 16.47 16.470 1 .032 ;.� DEVICES WITH CIRCUIT NUMBER ENGRAVED J 16.471 #10 #8W UNLESS NOTED OTHERWISE. E.C. SHALL A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL DOCUMENT DATE: 09-07-18 16.471 L4D2-18 VERIFY PRIOR TO ROUGH -IN THAT EQUIPMENT CONDUIT, AND CONDUCTORS AS INDICATED ON L3D2-36 UPS 16.470 EXISTING PANELBOARD HAS SPARE THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION. 16.470 16.032 CAPACITY TO ACCOMMODATE ADDITIONAL REMOVE ALL PANELBOARDS, DISCONNECT SWITCHES, BOXES, #8W LOAD. RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH WILL NOT BE REUSED. 16.472 FURNISH AND INSTALL NEW CIRCUIT B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT, 8'-6" 13'-1" 9'-5" BREAKER (##A-#P) IN EXISTING PANEL CONDUCTORS AND RELATED DEVICES SERVING SALES AREA INDICATED. E.C. SHALL MATCH TYPE AND GONDOLAS BEING RELOCATED OR REMOVED. EXISTING 1'-6" 1'-5" AIC RATINGS OF EXISTING CIRCUIT CONDUIT AND CONDUCTORS MAY BE REUSED FOR NEW BREAKERS. E.C. SHALL VERIFY PRIOR TO POWER DROPS WHERE SIZE, RATING, AND CONDITION MEET ROUGH -IN THAT EXISTING PANELBOARD REQUIREMENTS INDICATED ON PLANS AND ALL U.L. E010-003 HAS SPARE CAPACITY TO ACCOMMODATE RATINGS. REMOVE ALL UNUSED CONDUIT AND ADDITIONAL LOAD. CONDUCTORS BACK TO POINT OF ORIGIN WHENEVER 16.489 RELOCATE, EXTEND, AND RECONNECT FEASIBLE AND RELABEL DEMOLISHED CIRCUITS AS "SPARE". CIRCUITRY AND ELECTRICAL DEVICES FOR PROVIDE HANDLE DEVICE TO LOCK "SPARE" CIRCUIT RELOCATED AND/OR NEW EQUIPMENT. BREAKER IN THE "OFF" POSITION. VERIFY CONDITION OF BRANCH CIRCUITRY, C. CONDUIT AND WIRING TO BE ABANDONED IN CEILING CONDUIT, AND WIRE TO ENSURE THEY MEET ALL U.L. RATINGS AND REPLACE AS SPACES AND OTHER NON-PUBLIC AREAS (I.E., THROUGH REQUIRED. VERIFY FINAL LOCATION OF STOCKROOM AREA): CUT WIRING LOOSE AND REMOVE RELOCATED/NEW EQUIPMENT WITH FROM RACEWAY(S), LEAVING RACEWAY(S) IN PLACE. 0 WALMART CONSTRUCTION MANAGER PRIOR CONDUIT TO BE ABANDONED IN WALLS OR FLOORS SHALL TO ROUGH -IN. BE REMOVED BACK TO FINISHED SURFACE AND CAPPED INSIDE. REPAIR SURFACE(S) TO MATCH ADJACENT. 16.492 E.C. SHALL COORDINATE WITH GENERAL D. ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO BE No. (� CONTRACTOR AND ARCHITECTURAL ABANDONED OR REMOVED SHALL REMAIN IN RESPECTIVE DEMOLITION PLANS THE EXTENT OF ; ELECTRICAL DEMOLITION. REMOVE PANELBOARD FOR FUTURE USE, UNLESS NOTED OTHERWISE , o ON DRAWINGS. PROVIDE HANDLE DEVICE TO LOCK "SPARE" > O ' s r� jL CONDUITS AND WIRES ALL THE WAY BACK s ��• �' ® a TO ORIGINATING JUNCTION BOXES OR CIRCUIT BREAKER IN THE "OFF" POSITION. �i`�,S' �O < PANELBOARDS. DEMOLITION SHALL NOT E. DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO / AFFECT ACTIVE CIRCUITS. LABEL SELECTIVE SITE DEMOLITION SPECIFICATION FOR DEMOLISHED CIRCUIT(S) IN PANELBOARDS DISPOSAL OF LIGHT FIXTURE. AS "SPARE". COORDINATE EXACT F. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF SEP 07 REQUIREMENTS WITH EXISTING CONDITIONS WORK SHALL BE SECURED TO PREVENT FALLING,'�� ' PRIOR TO BID. LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE 16.957 CONNECT CIRCUITS) TO EXISTING BRANCH FUTURE. • �� CIRCUITRY. MINIMUM WIRE SIZE AND 17. ETHERNET CABLE: DOCUMENTS THAT DO NO1 ° PANELBOARD CIRCUIT ARE NOTED. HAVE THE ARCHITECT OR 3 2 VERIFY SIZE, RATING, AND CONDITION OF A. FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON ENGINEER OF RECORD EXISTING BRANCH CIRCUIT CONDUIT AND PLANS. PROVIDE CONDUIT AS REQUIRED BY LOCAL CODES SEAL AND SIGNATURE 0 E1 E1 WIRE PRIOR TO USE TO ENSURE THAT AND/OR ORDINANCES. SHALL BE CONSIDERED THEY MEET REQUIRED SIZE, AND ALL U.L. B. ETHERNET CABLE IS FURNISHED BY OTHERS. NOT FOR CONSTRUCTION RATINGS AND REPLACE AS REQUIRED. r - - - ®� 0 � - - - � C. ELECTRICAL CONTRACTOR SHALL INSTALL CABLE IN POWER 16.WO4 120 VOLT GENERAL POWER CIRCUIT(S): POLES. I ( OEM aI EXISTING FURNISH AND INSTALL NEW 20 AMP, D. ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE AS PANEL 120 VOLT CIRCUIT(S), OR AS SPECIFIED DIRECTED BY WALMART CONSTRUCTION MANAGER. ELECTRICAL ON ST I L3D1 1120 VOLT PANEL, WITH ADEQUATEEED FROM SPACEPLANS J I------J------J AND AMPACITY. UU ir A. CIRCUIT BREAKER FOR CIRCUITS -6 av XISTIN EDC3 INDICATED WITH (GFI) SHALL BE GFC1 PANE TYPE FOR PERSONNEL PROTECTION. L3D2 EXISTING EQUIPMENT EXISTING PANEL L4D3 ROOM PANEL L3U ri OVERALL POWER PLAN 1 /60" = 1'-0" E010-001 SHEET: El Un c 0 E E cn m c c J LL U) J_ _ W N 2i N d o LL M � N ry N � 00 M N N �-o U -- - --- - - - - -- - - - - F_ - T - - - - - -. - ---- - I -7 _ _ _- - - � I Ii I LLI 0 w Un � J � �' i- > no w0F } U) LL O L) ZLLIU aZ(DOQ LL wO5zUn� D UnF-z p HO,F-IUx - -F- QF F Un ILLi W W O LLwa�C❑ X W OU w w ~ Q J a W Q O_ ow Ow0 OaF-a J ZZQ�W Uco a- n Q O¢ W _ De U z o j w LLO LL2 `c 00wcwnw00W,F-02p O 3: ,W-Dozz�=z�-z owviQoa�W3:a=UOZQ ZLLJ Urm0E-Qz,<F Qp D DZN � z w 2 z W U Un O wL'f w p O E p02 wwmwSa_n0owZQ �waz�-OF-LL QxdzxU)m: 0000(L0 F_-DN W LL'�Q_�QF J sue- E c6 m z O CD 0%0 Jco co O .� co a r^ o �J J O co J a z J w C a-, o T_ O N go ry 0 i n W N w W m z 00 ISSUE BLOCK CHECKED BY: DW/CJ DRAWN BY: HS PROTO CYCLE: 07/27/18 DOCUMENT DATE: 09/07/18 WALLACE ENGINEERING - STRUCTURAL CONSULTANTS, INC. CERTIFICATE OF AUTHORIZATION #7027 DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION FIXTURE ANCHORAGE PLAN DETAILS AND NOTES SHEET E FXS1