HomeMy WebLinkAbout7631 Gall Blvd (29)ELECTRICAL SYMBOLS LEGEND 10-m.10 ESM (SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) SYMBOL DESCRIPTION / O FLUORESCENT / LED OR HID FDCTURE (WALL MOUNTED/CEILING MOUNTED) 10 FLUORESCENT/ LED FIXTURE ® FLUORESCENT I LED FIXTURE, NIGHT LIGHT ® VOLUMETRIC LED FIXTURE O ENCLOSED FREEZER LIGHT NZ Aa TRACK LIGHTING / ® EXIT FIXTURE (WALL MOUNTED) EMERGENCY LIGHT (KA-L MMOLNTED) SINGLE POLE SWITCH $3 3-WAY SWITCH $4 4-WAY SWITCH $K KEYED SWITCH 4D DIMMERSWITCH *VS VARIABLE SPED SWITCH 4m MANUAL MOTOR SWITCH SINGLE POLE OCCUPANCY SENSOR SWITCH DOUBLE POLE OCCUPANCY SENSOR SWITCH l CEILING MOUNTED OCCUPANCY RECEPTACLE, DUPLEX RECEPTACLE, DUPLEX, MOUNTED HORIZONTALLY RECEPTACLE, GFI ® RECEPTACLE, DUPLEX FLUSH FLOOR ® RECEPTACLE, DUPLEX. ISOLATED GROUND FLUSH FLOOR RECEPTACLE, DOUBLE DUPLEX x V RECEPTACLE, DUPLEX ISOLATED GROUND RECEPTACLE, DOUBLE DUPLEX, ISOLATED GROUND RECEPTACLE, SIMPLEX TWIST LOCI, L5-15R, UNO RECEPTACLE, SIMPLEX TWIST LOCK, ISOLATED GROUND, 1-5-1511, UNO RECEPTACLE, DUPLEX TWIST LOCK, 1-5-15R, UNO RECEPTACLE, DUPLEX TWIST LOCK, ISOLATED GROUND, L5-15R, LINO RECEPTACLE, SPECIAL d) RECEPTACLE, SIMPLEX �111 RECEPTACLE, PLUG -MOLD O JUNCTION BOX (WALL- MOUNTED) O I RMOSTAT (WALL MOUNTED/CEILING MOUNTED) �! ALARM JUNCTION BOX, (WALL MOUMEDICERM MOUNTED) ALARM JUNCTION BOX, ® FOR REMOTE TEST/RESET (WALL MOUNTEDICEILING MOUNTED) 0 EQUIPMENT CONNECTION POINT (PROVIDED WITH EQUIPMENT) NOWFUSED DISCONNECT Ell FUSED DISCONNECT CIRCUIT, CONCEALED N WNL.LS OR CEILING, E INDICATES EXISTING WIRING CIRCUIT, CONCEALED N SLAB FLOOR, E INDICATES EXISTING WIRNG CIRCUIT, EXPOSED, -�T E INDICATES EXISTING WIRING 1--t CONDUIT SLEEVE = FLASH MOUNTED PANELBOARD SURFACE MOUNTED PANELBOARD +------ MANUFACTURED WRING SYSTEM - TELEPHONE / DATA BOX FOR ISD LOW VOLTAGE CABLE BOX FOR OTHER m TELEPHONE, FLUSH FLOOR O MOTOR 0 TELEPOWE2 POLE 4 PUSH BUTTON aBUZZER SAIL SWITCH JUNCTION BOX SO SMOKE DETECTOR HORNISTROBE ® DOOR HOLD OPEN ABBREVIATIONS CF (SING FAN Co CHECK OUT CW CASHWRAP EF EXHAUST FAN ETR EXISTING TO REMAIN G GROUND GFI GROUND FAULT CIRCUIT INTERRUPTER IG ISOLATED GROUND REC REFRIGERATION ELECTRICAL CONTRACTOR RC REFRIGERATION CONTRACTOR RH RADIANT HEATER Sc SECURITY CAMERA TR TAMPER RESISTANT U H UNIT HEATER WH WATER HEATER WP WEATHER PROOF COVERPLATE WR WEATHER RESISTANT RECEPTACLE O RELOCATE LIGHT SWITCH TO V1ALL AND RECONNECT TO EXISTING LIGHTING CIRCUIT 1 I 3C F�� SEAFOOD INTERNAL HIGH POWER PLAN 10=1'4r KEY PLAN 1 11W _ V4r ELECTRICAL KEYNOTES 16.4V E.C. SHALL COORDINATE WffH GENERAL CONTRACTOR AND ARCI-IITECTURAL DEMOLITION PLANS THE EXTENT OF EECTRICAL DEMOLITION_ REAAOVE CONDIATS AND WIRES ALL THE WAY BACK TO ORIGINATING JUNCTION BOXES OR PN*jXV DS- DEMOLITION SHALL NOT AFFECT ACTIVECVZCUR& LABEL - DEMOLISHED CIRCUTP N PANE EX) ARDS AS'SPAW- COORDINATE EXACT REOLAtEMENTS WITH EXISTING CONDITIONS PRIOR TO BID. 16_W04 120 VOLT GENERAL PO W R CIRCUIT(S): FURNISH AND INSTALL NEW 20 AMP,12D VOLT CRCxUIT(S), OR AS SPECIFIED ON DRAWINGS Fib FROM NEAREST 120 VOLT PANEL, WITH ADEQUATE SPACE AND AMPACTTY. A CIRCUIT BAKER FOR CIRCUITS INDICTED WITH (GFI) SHALL BE GFCI TYPE FOR PERSONNEL PROTECTION_ 16.W07 208 VOLT GENERAL POWER CIRCUIT: FURNISH AND INSTALL NEW 208 VOLT CIRCUIT, AS SPECIFIED ON DRAWINGS. FEED FROM NEAREST 208 VOLT PANEL, WITH ADEQUATE SPACE AND AAMPACITY. GENERAL POWER NOTES 1 TELEPO NM POLE(S): MOUNT JUNCTION BOX(ES) TO TOP SIDE OF BOTTOM CHORD OF BAR JOIST_ INSTALL FURNISH® PRE -WIRED POWER POLE AND TERMINATE PROVIDED FLEXIBLE CONDUIT AND WIRING TO JUNCTION BOX. PROVIDE UNISTRUT SUPPORTS AND HARDWARE TO SECURE TE EPOWER POLE PL.LI B TO BUILDING STRUCTURE 2- PROVIDE LIQUID:nGHT FLEXIBLE METAL CONDUIT AND WIRING FROM DISCONNECT SWITCH OR JUNCTION BOX TO EQUIPMENT KNOCKOUT OR ELECTRICAL CONNECTION POINT. 3- WIBRE ErQI>pMENT NAMEPLATE PROTECTIVE DEVICE RATING DEFERS FROM S12E PROVIDED, CHANGE OUT BRANCH! CIRCUIT WIRING AND OVERCURRENT DEVICE TO APPROPRIATE RATING PER NEC. 4- ELECTRONIC FIRE PRoTEcTnvsEGuRrry ALARM BOXES AND CONDUITS SHOWM ON POWER PLANS SHALL BE PROVIDED UNDER THIS CONTRACT. N ADDITION, UNLESS NOTED OTHERWISE, THE FOLLOWING GENERAL NOTES APPLY: A- ALL ALARM JUNCTION BOXES SHALL BE 4'C4'X2-1/8' MINIMUM. B- ALARM RACEWAYS SHALL BE 314' MINIMUM WITH PILL VdRE AND NSt"TNG BUSHINGS AT END OF VERTICAL RA(EV1AY RUN. C- VERTICAL RACEWAYS FROM ALARM BOXES SHALL BE EITHER CONCEALED INSIDE WAALL OR SURFACE MOUNTED (TO MATCH JUNCTION BOX MOUNTING). ALL VERTICAL RUNS SHALL BE TURNED 900EGREES AT TOP SIDE OF BOTTOM CHORD OF BAR JOIST AND EXTENDED HORIZONTALLY TO A LOCATION ACCESSIBLE BY VERTICAL FLOOR TYPE LIFT. 5- UPON COMPLETION OF ELECTRICAL INSTALLATION AND PRIOR TO ENERGIZING CRCUIT- A- INSPECT WIRE AND CABLE FOR PHYSICAL DAMAGE. B- PERFORM CONTNUITY TEST. C- VERIFY PROPER PHASING CONNECTION TO ALL THREE PHASE MOTOR LOADS. 20A WIRE SIZING SCHEDULE ALL WIRE SIZES SHOWN ON PANEL SCHEDULES AND PLANS ARE INTENDED TO BE MINMALIIM ACCEPTABLE WIRE SIZE - THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE WIRE FOR 20 AMP CIRCUITS (120 AND 277 VOLT). LENGTHS; (N FEET) ARE INTENDED TO BE MAXIMUM. FINAL CONNECTIONS: WHERE 20A BRANCH CIRCUITS HAVE 08 AND LARGER WIRE CALLED OUT, #10AWG WIRE MAY BE USED FOR THE FINAL CONNECTION (16 MAX.)_ 12D VOLT #12 #10 #8 #6 1S AMPS 200 FT. 325 FT. 4W FT. 7T0 HT. 6-10 AMPS 100 FT. 160 FT. 245 FT. 385 FT. 1145 AMPS 70 FT. 110 FT. 165 FT. 255 FT. 277 VOLT #12 #10 #8 #6 1S AMPS 4W FT. 760 FT. 1170 FT. 1865 FT. 6-10 AMPS 240 FT. 380 FT. 585 FT. 930 FT. 11-15 AMPS 160 FT. 250 FT. 390 FT. 620 FT. GENERAL NOTES 06.31.12 EN08 1- FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND LABOR, FOR A COMPLETE INSTALLATION IN ALL RESPECTS, READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH NEC, NESC, STATE, AND LOCAL CODES, AND MANUFACTURERS RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS. A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS THE ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR WVALL.S. B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE OPERATIONS. COORDINATE ALL DISRUPTIONS WITH WWLMART CONSTRUCTION MANAGER AND STORE MANAGER. D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESSES BEFORE INSTALLING BOXES. FURNISH AND INSTALL EXTENDED BOXES OR BOX EXTENDERS WHERE REQUIRED. E- CONTRACTOR SHALL VERIFY THAT ALL AFFECTED PANEBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS PROPERLY COVERED AND THAT ALL TRIM IS IN GOOD CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. 2- PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: A- FIRE RATED WALLS- SEAL PER SPECIFICATIONS FOR FIRE STOPPING. B NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL C FREEZERCOOLER BOXES: SEAL WITH EXPANDING FOAM SEALANT. D- EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY PENETRATIONS. 3- PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR (SIZE PER NEC) N PVC TYPE CONDUIT, POWER CIRCUITS, ISOLATED GROUND CIRCUITS, OR AS SHOWN ON PLANS. CONDUIT SHALL BE SIZED PER NEC BASED ON THWN 600 VOLT COPPER SINGLE CONDUCTORS, PLUS THE EQUIPMENT GROUNDING CONDUCTOR 4- WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM FINISHED FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED OTHERWISE ON PLANS. COORDINATE THE STANDARD MOUNTING HEIGHTS WITH MASONRY: A. SWITCHES +46' B. RECEPTACLES +20' C. VOK;F"TA +20' 5- WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT IN CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING DIAGRAMS. 6- CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE PANELBOARD IDENTIFICATION SCHEDULES FOR PANE BOARDS AFFECTED BY REMODEL- 7- NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHALL MATCH THE TYPE AND AIC RATING OF EXISTING OVERCURRENT PROTECTIVE DEVICES 8- BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG THHN UNLESS NOTED OTHERWISE N SCHEDULES. WHERE 20A BRANCH CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 AWG WIRE SHALL BE USED FOR THE FINAL CONNECTION (15-FT MAXIMUM)_ 9. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND DERATE CURRENT CARRYING CONDUCTORS PER NEC. 10. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. UTILIZE ONLY THE TOP AND BOTTOM CHORDS FOR SUPPORTING THE ELECTRICAL SYSTEM INSTALLATIONS. 1i. DEVICES SHOWN ON COOLEWFREEZER PANELS SHALL BE SURFACE MOUNTED UNLESS NOTED OTHERWISE REFER TO ARCHITECTURAL DOCUMENTS FOR CONDUIT INSTALLATION AND SEALING REQUIREMENTS. 12. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM AND BRANCH CIRCUITS NOTED BY LEGEND SHALL BE INSTALLED UNDER SLAB. ALL OTHER FEEDER AND BRANCH CIRCUITS SHALL BE INSTALLED OVERHEAD. PROVIDE EXTERIOR COATED GRC BENDS ON ALL CONDUIT RUINS THAT HAVE 45 DEGREE BENDS OR GREATER REF SPECIFICATIONS. 13. SEISMIC ZONE REQUIREMENTS-. PROVIDE EXPANSION COUPLINGS AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY LOCAL CODES. 14. EXISTING ELECTRICAL AND ALARM: A- WHERE DEMOLITION OR NEW INTERRUPTS EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING EQUIPMENT, DEVICES, OR LIGHTING TO REMAIN, BUT NOT SHOWN ON DRAWINGS, PROVIDE LABOR AND MATERIALS TO REWORK CIRCUITRY, AS REQUIRED, TO MAINTAIN EXISTING OPERATION. B• IF DEMOLTION OR NEW CONSTRUCTION WILL DISRUPT EXISTING UNDERGROUND SERVICES (ELECTRICAL, TELEPHONE, PARKING LOT LIGHTING CIRCUITRY, ETC-) PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO REROUTE, SLEEVE, OR OTHERWISE REWORK THESE SERVICES TO MAINTAIN THEIR EXISTING OPERATION. C LSE CAUTION AROUND At AND SECURITY CABLES - EXERC DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO THAT SYSTEMS REMAIN OPERATIONAL AT ALL TINES. D- DISPOSE OF ALL REMOVED MATERIALS, UNLESS OT'HERWWSE NOTED. 15. EXISTING ELECTRICAL DEbbLf170N: A- GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL EQUIPMENT CONDUIT, AND CONDUCTORS AS INDICATED ON THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION. SCO NE T SWITCHES BOXES 0 w m m%O Cw0Dy W p moMaz wTwww w 1a ix ~Q���mam°am lL cFLI 0) aLLF?Wit Wi z 22 �am�00 rOZp O g 0 ogj`�fsa- $� 05 m�� I'i p D a luo aumn—wom IL pmo"'°�g` Sma°cmw S w x i nook-0 ww-wx Ego gZ■ 0 � S Z z �_ U �$ z w O O w O C= OO J w O J M $ Z 1.i.. 0 Z O N N w m D z O ISSUE BLOCK I CHECKED BY: SAG DRAWN BY: JOP FEE N E1 PROTO CYCLE 07/03/18 DOCUMENT DATE: 07/25/18 REMOVE ALL PANELBOARDS, DI N C , RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH WILL NOT BE REUSED. B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT, CONDUCTORS AND RELATED DEVICES SERVING SALES AREA GONDOLAS BEING RELOCATED OR REMOVED. EXISTING CONDUIT AND CONDUCTORS MAY BE REUSED FOR NEW POWER DROPS WHERE SIZE, RATING, AND CONDITION MEET REQUIREMENTS INDICATED ON PLANS AND ALL U.L RATINGS. REL40VE ALL D CONDUIT AND CONDUCTORS BACK TO POINT OF ORIGIN WHENEVER ����````0' FEASIBLE AND RELABEL DEMOLISHED CIRCUITS AS'SP, PROVIDE HANDLE DEVICE TO LOCK'SPARE' CIRCUIT * 19 BREAKER IN THE `OFF` POSITION. = * = C- CONDUIT AND WIRING TO BE ABANDONED IN CEILING " 78 L ST SPACES AND OTHER NON-PUBLIC AREAS (I.E., THROU6g,0wk ; uG 0 3 2�t8 STOCKROOM AREA): CUT WIRING LOOSE AND REMOVE�i �iQ "' O pP �� ��� FROM RACEWAY(S), LEAVING RACEWAY(S) IN PLACE - CONDUIT CONDUIT TO 13E ABANDONED IN WALLS OR FLOORS SHALL /lllll BE REMOVED BACK TO FINISHED SURFACE AND CAPPED INSIDE. REPAIR SURFACE(S) TO MATCH ADJACENT. RIIINI�1 ' ��' P.E. D- ALL C9RCUT BREAKERS SERVING BRANCH CIRCUITS TO BE FL I179819 ABANDONED OR REMOVED SHALL REMAIN IN RESPECTIVE PANELBOARD FOR FUTURE USE, UNLESS NOTED OTHERWISE ON DRAWINGS. PROVIDE HANDLE DEVICE TO LOCK'SPARE` CIRCUIT BREAKER IN THE'OFF' POSITION. E- DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO SELECTIVE SITE SON SPECIFICATION FOR DISPOSAL OF LIGHT FIXTURE. F. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE FUTURE. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT AS-BUILr CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDIITONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION ION WITH ALL OTHER DIMMES AMID EXISTING CONDITIONS. NOTE: RECEPTACLES, SWITCHES, DATA BOXES AND THEIR CORRESPONDING COVER PLATES SHALL BE WHITE NYLON. EACH SLBCONTRATOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE ELECTRICAL PLANS SHEET - El