HomeMy WebLinkAbout37924 Medical Arts CtDRAWING INDEX A DENTAL/ MEDICAL SUITE RENOVATIONS for 0 C ty C, p Inco Premier ommuni Healthcare rou V A./ rv, ARCHITECTURAL AO COVER PACE SITE PLAN Al PROJECT INFORMATION DEMOLITION PLAN A2 NEW CONSTRUCTION FLOOR PLAN FRAME/ OPENING SCHEDULE A3 LIFE SAFETY PLAN DETAILS A4 REFLECTED CEILING PLAN ROOM FINISH SCHEDULE A5 INTERIOR ELEVATIONS A6 SPECIFICATIONS A7 SPECIFICATIONS MECHANICAL MI MECHANICAL LEGEND AND SPECIFICATIONS 37924 MEDICAL ARTS COURT ZEPHYRHILLS, FLORIDA M2 MECHANICAL DETAILS M3 MECHANICAL SCHEDULES M4 MECHANICAL SCHEDULES M5 MECHANICAL DEMOLITION PLAN M6 MECHANICAL CEILING PLAN M7 MECHANICAL EXHAUST 6 PIPING PLAN PLUMBING P1 PLUMBING FIXTURES SCHEDULE P2 PLUMBING DETAILS P3 PLUMBING DEMOLITION PLAN P4 PLUMBING FLOOR PLAN P5 MEDICAL CAS PLAN CONSTRUCTION DOCUMENTS P6 WATER ISOMETRIC RISER P7 SANITARY ISOMETRIC RISER P8 BENCO PLANS- FOR REFERENCE ONLY CLIENT INFORMATION: PREMIER COMMUNITY HEALTHCARE GROUP, INC. 37912 CHURCH AVENUE DADE CITY, FLORIDA 33525 Tel : 352-518-2000 Robert J. Lence a r c h i t e c t incorporated 3818 Gunn Highway Suite 102 Tampa, Florida 33618 813.963.1066 813.963.1168 fax robe rtj len ce(q-_DaoI. com AA26001576 MECHANICAL & PLUMBING ENGINEERING STEPANEK-LEWIS AND ASSOCIATES 2257 TWELVE OAKS WAY SUITE 103 WESLEY CHAPEL, FLORIDA 33544 (813) 991-1248 MATT@STEPANEKLEWIS.COM ELECTRICAL ENGINEERING CHEHAYEB &ASSOCIATES, INC. 3702 AZEELE STREET TAMPA, FLORIDA 33609 (813) 876-1415 TODD. MILLER@CHEHAYEB.COM REVIEWIDATE CITY OF ZE;WHI FIREAN LIFE SXFETyEMM1NER__kJ_- ALL WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS �4 I AG - LL 'I'VORK SHAI L COMPLY WITH PREVAILING CODES FLO�& BUILDING NATIONAL ELECTRIC CODE.CODE' AND THE CITY OF ZEPHYRH-ILLS ORDINANCES ELECTRICAL El ELECTRICAL NOTES AND LEGEND E2 LIGHTING PLAN E3 LICHT FIXTURE SCHEDULE AND DETAILS E4 POWER PLAN E5 ELECTRICAL DETAILS E6 POWER RISER DIACRAM E7 PANEL BOARD SCHEDULES E8 ELECTRICAL SPECIFICATIONS DENTAL EQUIPMENT PLANS (NOTE 'A') Q0.1 COVER SHEET Q1.1 DENTAL EQUIPMENT PLAN Q2.1 DENTAL CARPENTRY PLAN ��5j2.2 DENTAL CARPENTRY PLAN Q3.1 DENTAL ELECTRICAL PLAN Q3.2 DENTAL ELECTRICAL DETAILS Q4.1 DENTAL PLUMBING PLAN (.,'Q 4. 2 DENTAL PLUMBING DETAILS DENTAL CABINET PLANS (NOTE *A*) -1 MIDMARK CABINET DRAWINGS -2 MIDMARK CABH14ET DRAWINCS MDK-3 MIDMARK CABINET DRAWINGS MDK-4 MIDMARK CABINET DRAWINCS I MDK-5 MIDMARK CABINET DRAWINGS NOTE 'A': CONTRACTOR TO CONFIRM THAT DENTAL EQUIPMENT PLANS AND DENTAL CABINET PLANS ARE FINAL BEFORE START OF CONSTRUCTION HIMPE SITE AERIAL PHOTOGRAPH NTS Issue Date 09-03-21 6 a) Coll (0 CO 0 M (D LL < J� Z Co Z CL LL ::) E C: o M (0 a) 00 - N OD 0 M - 20) U) 0 6 C: Q_ U) :3 0 C: 0 0 co (D > 0 (D _E C: N 0 Cn < Ica S-0 0 C: N E Job Number 2008 Revisions A ,%eet No. AO IT __ I u 111 1 PROJECT DATA BUILDING OAT CLASSIFICATION BY OCCUPANCY BUSINESS FIRE PROTECTIVE REQUIREMENTS CLASSIFICATION BY GROUP 5 REQUIRED PROVIDED PARTY AND FIRE WALLS I HOUR 2 HOUR HAZARD OF CONTENTS LOW HAZARD INTERIOR BEARING 2 HOUR 2 POUR CONSTRUCTION TYPE rp-5 COLUMNS N/A N/A PROTECTED UNPROTECTED X BEAMS, GIRDERS, TRUSSES N/A N/A 5PRINKLERED YES 1-1 NO FXI FLOOR CONSTRUCTION N/A N/A ROOF: CONSTR14CTION N/A N/A INTERIOR IMPROVEMENT (a) YES Fx_1 NO [-] I -XI F-1 MEANS OF: EGRESS MECHANICAL MEZZANINE (b) YES NO (a) SINGLE TENANT OCCUPANCY NO. OF: OCCUPANTS IN BUILDING (b) AIR HANDLING UNITS IN ATTIC WAITING ROOMS= WOO SF/ 15 54 BUILDING VARIABLES ALLOWABLE PROVIDED BREAK ROOMS- 24455F/ 15 16 REST OF 5LDG- (o'311 SF/ 150 41 BUILDING HEIGHT 351-011 1-11-011 TOTAL - Ill NUMBER OF STORIES 2 1 EGRESS WIDTH REQUIRED EGRESS WIDTH PROVIDED TOTAL BUILDING AREA C30M SF 1C355 w III x.2 m 24" 26611 AREA OF INTERIOR IMPROVEMENTS NO LIMIT 4-156 SF MINIMUM NO. OF EXITS REQUIRED 2 FRONT SETBACK N/A N/A NUMBER OF EXITS PROVIDED I REAR SETBACK N/A N/A MAX. TRAVEL TO EXIT MAX. DISTANCE PROVIDED SIDE SETBACK N/A N/A 200'-0" &11-011 DEMOLITION PLAN KEY NOTE F_q1 EXISTING ATTIC ACCESS PANEL TO BE REMOVED F-1 I EXISTING INTERIOR WALL TO BE REMOVED IK EXISTING GYP BOARD CEILING IN SUITE'B'TO BE REMOVED IN ITS ENTIRETY. REMOVE ABOVE CEILING INSULATION AND REPLACE F2] EXISTING INTERIOR DOOR AND FRAME TO BE REMOVED. SAVE WITH NEW R-19 INSULATION ABOVE NEW CEILING TILES FOR POSSIBLE REUSE F-111 EXISTING SURFACE MOUNTED LIGHTING IN SUITE'B'TO BE F-31 REMOVE EXISTING PLUMBING FIXTURES AND CAP OFF REMOVED IN ITS ENTIRETY PLUMBING LINES N1 EXISTING ADA RESTROOM LOCATIONS TO REMAIN, PLUMBING F4] EXISTING INTERIOR WINDOW TO BE REMOVED FIXTURES TO BE RELOCATED AS REQUIRED TO MEET CURRENT ADA CLEARANCE REQUIREMENTS 51 EXISTING MILLWORK TO BE REMOVED Fl-31 PORTION OF EXISTING MASONRY TENANT SEPARATION WALL TO BE REMOVED AS REQUIRED TO INSTALL NEW T-O" WIDE RATED 1_61 EXISTING ELECTRICAL PANELS TO REMAIN UNDISTURBED- DOOR. DOOR SHALL BE HELD OPEN WITH ELECTROMAGNETIC SEE ELECTRICAL PLANS DEVICE AND RELEASED UPON SMOKE DETECTOR ACTIVATION. - THIS WORK SHALL BE INCLUDED IN PHASE ONE WORK (SUITE A) M EXISTING DOOR AND FRAME TO REMAIN. NOTE: APPEARANCE OF NEW INTERIOR DOORS AND FRAMES TO MATCH F1­4] REMOVE EXISTING PLUMBING FIXTURE AND REPLACE WITH NEW APPEARANCE OF EXISTING INTERIOR DOORS AND FRAMES FIXTURE SET IN NEW MILLWORK. SEE INTERIOR ELEVATIONS EXISTING INTERIOR WALL TO REMAIN E EXISTING INTERIOR POCKET DOOR TO BE PERMANENTLY LOCKED F181 An SUITE 'A' DENTAL= EXIT _.dft� CODE REFERENCE APPLICABLE CODES: FLORIDA BUILDING CODE 2020- -1TW EDITION FLORIDA PLUM51NG CODE 2020- 1TW EDITION FLORIDA MECHANICAL CODE 2020- 1TW EDITION STANDARD FUEL GAS CODE 2020- 1TW EDITION TEST PROTOCOLS FOR HIGH VELOCITY HURRICANE ZONES 2020- 1TI4 EDITION FLORIDA ACCESSIBILITY CODE (F5C 2020- -ITI4 EDITION NATIONAL ELECTRIC CODE (CURRENT EDITION) NFPA 101 LIFE SAFETY C40DE (CURRENT EDITION) STANDARD FIRE PREVENTION CODE (CURRENT EDITION) TO COMPLY WITH LEVEL OF ALTERATION- LEVEL 3 (AREA OF: INTERIOR RENOVATIONS- 4'15&/1W!px FIRE PREVENTION NOTES I. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH MINIMUM 2AI05C RATING 2. EVERY EXIT DOOR SHALL BE OPENA15LE FROM INSIDE WITHOUT A KEY OR SPECIAL KNOULEDGE 3. EXISTING EXIT SIGNAGE SHALL COMPLY WITH FLORIDA BUILDING CODE AND ALL APPLICABLE STANDARDS. 4. AS, REQUIRED TWE CONTRACTOR $14ALL PROVIDE AND INSTALL 5 LB, ABC FIRE EXTINGUISHERS, SURFACE MOUNTED, PER FIRE MAIRSWALL'S INSTRUCTION$ TO MEET CODE MINIMUM 5. PROVIDE ACCESS BOX FOR FIRE DEPARTMENT (FIRE MARSHALL APPLICATIONS) Z� ALIGN WALLS EXISTING EQUIPMENT TO BE REMOVED/ RELOCATED TO RENOVATED SPACE EXISTING EXTERIOR DOORS AND WINDOWS TO REMAIN UNDISTURBED F_1q1 EXISTING EXTERIOR DOOR TO BE PERMANENTLY LOCKED EXISTING AC CONDENSING UNITS- SEE MECHANICAL EXISTING ELECTRICAL METER LOCATIONS- SEE ELECTRICAL ALL EXISTING FLOOR FINISHES AND WALL BASE TO BE REMOVED. WHERE TILE FINISH EXISTS, REMOVE ALL MORTAR AND USE SELF -LEVELING FLOOR PATCH COMPOUND WHERE NECESSARY TO PREPARE FLOOR FOR NEW FINISH. SEE ROOM FINISH SCHEDULE F 25] ALL EXISTING CEILINGS, CEILING GRIDS, LIGHT FIXTURES, AC DIFFUSERS, INSULATION ABOVE CEILING TILES, ETC. TO BE REMOVED. SEE REFLECTED CEILING PLAN NO: RENOVATIONS TO SUITE 'E3' EXIT AC I X1.S1 ELEC il q E X.- I ins z7ZZ11111777-1-771117177 . . . . . . 1/,, 7 7 7 7 Z 7 zz� ------------------------------ ELEC ELEC rr- E><IST,,, 7 EXIST I _T­Ir 4/ 2] F I - TOILE Eli \E31F L J [fl I FAMILY FC EXAM L _j L_ I I L - - - - - - - - - - T1 a4 El� I E2] L _L _j Lj_ - - - - - - - L� =-T ----- - 2TI ATTIC F _1 F 1 -ACCESS - Eq] L - - - - L=_j - - - - - - 2 F2 2� F ---------------- EXIST ELEG CLOSET L FAMILY I EXA F11 I I M E5_1 F i, ) LL =:�j L _i_ - I �, I/ r ------ F121 Ir - - - - - - - - EXIST TOILE I LL=7�j �22 1 1 < _j I =q f!I-ATT C Ey I I I n_ - > FAMILY ACCESS rrr_ EXA 7 FT . . . . . . . 2� E FBI E5_1 C _- D F2] L 4 F2TI LL_ r=� L - - - - F- - - - - - - - 2] -n I I < F-T--� El- EB-1 1-51 FAMILY L L ---------- I EXAM ------------ ---- ------- ----------- ====3= �22 P 177] F21 E2] I E2TI �10 �22 _T F FAM I LY EXIST > EXA TOILE [2] I [fit 121 F Ff lELwo�j 11 L, - - - - - - - - - - - - - - - 3 FBI EXIT ELE El 111 F­___1 Fil DOCTO HT-1 �`IILY ;ZSES �Tlo z PROJECT NOTES 1. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE CODES AND STANDARDS, INCLUDING, BUT NOT LIMITED TO ALL STATE LAWS, LOCAL ORDINANCES, UTILITY CO. REGULATIONS AND APPLICABLE REQUIREMENTS OFSTANDARD MECHANICAL CODE, OCCUPATIONAL SAFETY AND WEALTH ACT, FIRE PROTECTION ASSOCIATION, N.F.P.A. AND THE 2020 FLORIDA BUILDING CODE-'ITW EDITION 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL DIMS. AND EXISTING CONDITIONS PRIOR TO BIDDING AND CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE ARCHITECT AND OWNER PRIOR TO BIDDING AND CONSTRUCTION. 3. GC TO REMOVE ALL DEBRIS FROM THE SITE AS REQUIRED TO MAINTAIN A SAFE AND ORDERLY CONDITION. 4. THE PLANS SHOW THE LOCATION OF ALL FIXTURES AND EQUIPMENT AND ARE INTENDED TO CONVEY THE GENERAL INTENT OF THE WORK IN SCOPE AND LAYOUT. THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL EVERY AND ALL ACCESSORIES INTENDED FOR THE PURPOSE OF: EXECUTION OF THE WORK, BUT 19 UNDERSTOOD THAT SUCH DETAILS AIRE PART OF THIS WORK 5�. THE CONTRACTOR $14ALL OBTAIN ALL PERMITS NECESSARY FOR CITY, COUNTY, AND STATE COMPLIANCE PRIOR TO COMMENCING CONSTRUCTION. IF SPECIAL PERMITS ARE REO'D. THEY SHALL BE 05TAINED AND EXHIBITED BY TWE CONTRACTOR AND SHALL GIVE NOTICE$ AND COMPLY WITH THE LAWS, ORDINANCES, CODES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS PER DOCUMENTS. 6. GENERAL CONTRACTOR SHALL COORDINATE UTW OWNER ALL MATERIALS AND EQUIPMENT FOR REVIEW PRIOR TO FABRICATION AND / OR INSTALLATION. -1. ALL INTERIOR JOINT$ BETWEEN DISSIMILAR MATERIALS SHALL BE CAULKED. ALL EXTEIRIOR JOINTS TO BE SEALED. 8. ALL EXPOSED STRUCTURE, UTILITIES, CONDUIT, ACCESSORIES, ETC. __j5HALL 5E-COMPLETELY PAINTED. 15. DO NOT SCALE DRAWINGS. IS. GENERAL CONTRACTOR TO ADJUST DIMENSIONS TO EXISTING CONDITIONS AND PREFABRICATED 10. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF COMPONENTS. CONFIRM W1 OWNER BUILDING SETBACK LINES BEFORE COMMENCING ANY NEW CONSTRUCTION. UNDER NO CONDITION $14ALL THE NEW BUILDING 20. ALL DIMENSIONS ARE TO FACE OF: INTERIOR FINISH ON EXTERIOR WALLS EXCEED THE MINIMUM REQ'D SETBACKS SET MASONRY (GWI5) OR FACE OF METAL STUDS (U.ON.) FORTH IN THE BUILDING AND ZONING DEPARTMENT. NOTIFY OWNER OF ANY DISCREPANCIES THAT MAY EXIST BETWEEN 21, FAINT OR FINISH ALL EXPOSED UTILITIES. EXISTING AND ACTUAL CONDITIONS AND THE INFORMATION 22. TWE CONTRACTOR $14ALL FURNISH ALL MATERIALS, REPRESENTED IN THESE PLANS. EQUIPMENT, LA50K AND OTHER FACILITIES I]. CONTRACTOR TO VERIFY MASONRY OPENING SIZES W1 DOOR AND NECESSARY FOR THE EXECUTION OF THE WORK. ALL WINDOW MANUFACTURER PRIOR TO ORDERING NOTIFY ARCHITECT MATERIALS SHALL BE NEW AND 50TH WORKMANSHIP IF MASORNY OPENINGS REQUIRE CHANGES TO DIMENSIONS FROM AND MATERIALS SHALL BE OF QUALITY EQUAL TO OR THOSE SHOWN ON PLANS TO ACCOMODATE DESIRED WINDOW AND ABOVE INDUSTRY STANDARDS. DOOR/FRAME SIZES. 23. GC $14ALL COORDINATE ALL DRAWINGS AND 12. ALL WOOD THAT COMES IN CONTACT W1 CONC. OR EXPOSED TO IMMEDIATELY NOTIFY ARCHITECT OF ANY HIGH HUMIDITY SHALL BE PRESSURE TREATED. ALL EXPOSED DISCREPANCIES OR OMISSIONS PRIOR TO PRICING OR WOOD SHALL BE SQUARE EDGE SELECT. START OF WORK 13. ALL METALS SHALL HAVE GALVANIZED FINISH, TYP. (UON) 24. GENERAL CONTRACTOR SHALL PROVIDE PLYWOOD BACKING OR SU56TRATE AS REQUIRED TO 14. COINER BEADS, CASING 5EADS, OR J-MOLDS SHALL BE STRUCTURALLY SUPPORT WALL MOUNTED FIXTURES, APPLIED TO ALL CORNERS AND WALLS ENDS. MILLWORK, OR EQUIPMENT TWAT 15 INCLUDED IN THE SCOPE OF WORK OF: THIS PROJECT. 15. PROVIDE CONTINUOUS 5EAD OF SEALANT AND CAULKING AROUND EXTERIOR AND INTERIORS OF: ALL DOORS AND WINDOWS. DO 2 5. ALL DISSIMILAR METALS TWAT COME IN CONTACT WITH NOT SEAL AT EXTERIOR WEEPS. EACH OTHER SHALL BE SEPARATED WITH 51TUMENOUS COATING OR OTHER MEANS TO PREVENT GALVANIC 16, CONTRACTOR TO PROVIDE TEMPORARY BARRIERS SURROUNDING ACTION TO OCCUR CONSTRUCTION AREAS AS REQUIRED TO ENSURE PUBLIC SAFETY. 26. UNLESS OTHERWISE NOTED, ALL NEW CONSTRUCTION TO 1-1. PROVIDE INSULATION AROUND ALL PLUMBING LINES TO PREVENT MATCH EXISTING CONSTRUCTION TO INCLUDE INTERIOR SOUND TRANSMISSION THROUGH WALLS. FLOOR, BASE WALL AND CEILING FINISHES, MILLWORK, 18. ALL STORMWATER AND RUNOFF SHALL BE ROUTED TO EITHER LIGHTING AND PLUM51WG FIXTURES, ETC. IT SHALL BE LOCAL RETENTION AREA OR PUBLIC STORM SEWER INLET BY THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD SURFACE SWEET FLOW OR UNDERGROUND PIPINGAND SHALL NOT VERIFY EXISTING CONDITIONS BEFORE 51DOING THE J05 CROSS ANY ADJOINING PUBLIC PROPERTY. PROJECT PHASING WALL LEGEND 1. ALL WORK ASSOCIATED WITH SU ITEW (DENTAL) AND SUITE 'C'(PEDIATRICS) SHALL EXISTING EXTERIOR TYPICAL NEW INTERIOR WALL (U.O.N.) BE CONSTRUCTED AS "PHASE ONE CONSTRUCTION" MASONRY WALL TO 3 5/8" 22 GA. METAL STUDS AT 2. ALL WORK ASSOCIATED WITH SUITE 'B' (FAMILY MEDICINE) SHALL BE REMAIN 16" O.C. W/ 5/8" GYP. BOARD EACH SIDE. PROVIDE SOUND BATT CONSTRUCTED AS "PHASE TWO CONSTRUCTION" INSULATION BETWEEN STUDS AND USE MOISTURE RESISTANT GYP. 3. OWNERS INTENT IS TO PERMIT BOTH PHASES SIMULTANEOUSLY AND TO BUILD BOARD AT ALL WET WALLS AND HIGH HUMIDITY AREAS TYP, WALL TO PHASE TWO CONSTRUCTION IMMEDIATELY UPON COMPLETION OF PHASE ONE ETI� EXISTING INTERIOR EXTEND 6" ABOVE FINISHED CEILING AND BE BRACED TO STRUCTURE CONSTRUCTION MASONRY WALL TO ABOVE. NOTE: SOUND ATTENUATION INSULATION TO OCCUR AT ALL 4. SEE DEMOLITION PLAN, SHEET Al, FOR EXTENT OF PHASE ONE CONSTRUCTION REMAIN INTERIOR PARTITIONS. INSULATION SHALL EXTEND FULL HEIGHT OF AND PHASE TWO CONSTRUCTION WALL FRAMING (ABOVE CEILING LEVEL). SEE VA3 5. CONSTRUCTION BIDS SHALL BE SUBMITTED IN TWO PARTS, AS FOLLOWS: EXISTING INTERIOR BID 1 SHALL CONSIST OF ALL WORK ASSOCIATED WITH SUITEW(DENTAL) FRAMED WALL TO TYP NEW 6" MTL STUD WALL REMAIN NEW CONSTRUCTION INTERIOR PLUMBING WALL- 6" 22 GA. METAL BID 2 SHALL CONSIST OF ALL WORK ASSOCIATED WITH SUITE'B'(FAMILY MEDICINE) STUDS AT 16" O.C. W/ 5/8" GYP. BOARD EACH SIDE. SOUND AND SUITE'C'(PEDIATRICS) ATTENUATION INSULATION FULL HEIGHT OF WALL. USE MOISTURE im EXISTING WALL TO BE RESISTANT GWB AT ALL WET WALLS AND HIGH HUMIDITY AREAS. REMOVED (U.O.N.) FE DOCTO If F7 BULKHEAD ABOVE FE IC,INE= EXIT 10-1 SF 1. P�4ASE ONE: RENOVATIONS TO SUITE 'C' PEDIATRICS= 3000 SF EXIT Aft - Issue Date 09-03-21 Lo 2 _j LL Z (a z CL LL E (o 9 (D co 0 - 04 co 0 cl) - So 0 w mw m CL _0 -c: :3 0 0 LL 0 cl) > (D c- 0 c CU (D 0 -C N (D 1-0 co ELEC ELEC U Fl-51 E I a] aj L�j [j] [E F, 5EI K71717771"17777z:3 I P=/ co 0 11 1 1 1 1 TT I =1 E==:=7� E 4- ---------- I I I I I I I I 1T I I I I I I IN 0 I - � 51 FE 5 3 3 ELEC - I I I �_E DOCTOR 0­41 F1_2] STORAGE I I RN IT UTILIT ELEC I BREAK ROOM I PEDI I EXA FE I _L LIH-rfl i I C I�Lp 6 JELE F__ _j I I LL_ 1-/ E FE - 1_� i�T - 11 - [ 21 ED I L --- i I- ------ TOILET _77 -------- El F2] E L ------------ FF�__71 - --- ------ 1 2 -------------- Ell 0 (1) L -1 L Z M! Efl El _j LAr --- F --- I f IN qz!; Lrp T, t_ - __: _71=� BULKHEAD F11 // PEDI 1E L_ ABOVE FT_ EXA a) L_ 11 C) -T-- Eli ------ E-� - -F1 :::I ir--- I 1 17 E 71-7 1 F - - -1 co I I I / F I I LI --- il - 111 R2 2 1 f o- 2 L ---------- =1 --- I - (D El 1 11 F11 / / I i 1 1 El 11 1 171 1771 ____L--- �rL __ f T IFF 11 ___T_ --- A Jill 11 IF LL E5 LjL - A _U IL ill i F ED, I IF - L--J a - J 6 ADMIN +4-T ME[) LEH,, E i I L ca E OFFIC -TOP 1 1 - I - END, I I TOILET JA L - - - - - - - L___J PEDI t ---- H Job Nurnber 1 11 1 1 EXAM ---------- LL-==,J � J_ L 1-y- T -------------- 2008 ---------------- -- 22 El rl� 'IF PEDI E L J LOCKABLE L-= D, ADMIN MED I I ST TIO ------------ f5 OFFIC SUPPL. -------- FOCKETI 51 L --------- I F ­1 1 0 DOOR I L r7] PED1 I I NATER F;_ EXA I I 50TTLE COPY I I I I. r-BULKHEAD L ----- ABOVE 171 RECEPT/ ADMIN F 11,111 [2 IF - r57 -1 1 Ell t El F - V-LIf, ---- L ----- j I --- �l I I - L --- J R11 E F-7 F--- _j, D-1 BULKHEAD PEDII A50VE 31-011 EXA ] Zal (;O�7 M DOOR KIDS Fil CE EEL I- I PLAY AREA TOI LET t 7 L --- J- r F -7 7:_ ==-=-p \ E FT1 FAMILY'\ ii I I / L 1 14 - \ 13 tzj=====q r_____1 - OFFIC _j > FAMILY�/ F17 EXA OFFICE MANAGE EXA I I ED-1 �-E BLOOE) FAMILY PEDIATRIC Fil / FAMI Ly f____ - F7 -9 PEE)l EXA 1 1 1 1// \ I DRA NAITIN NAITIN VITAL ILL:i EXA > I I I I I L___ I I < < NENBORN (T I j Fr= F NENBORN5 E a 1 1 1 ILL tll� L L%_ Ij I I 1/ 7.7 7 77 7 7 z 7 7 1:7 z F, 81 11-81 1-1-81 r1_81 F, 8EI Fl-81 F, a] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - w - - - - - - - - - - - - - - - - - - - 1 11) H I E I- I :I Li I I U 1. EXIT DENIOLITI N FLOOR I :ILAN Sheet No. EXIT SCALE: 3/16" IT '-011 Al N - i�_ __T 1-T __ 7 1: E I .; iu, � I E_Ellh, _._� .11.1, � - L I - J_u I _�i I I F FRAME / OPENING SCHEDULE No. Elev. Width Height Thick Material Frame Hi Remarks Q C 0-811 1 514" ND/GL ND -I 1,2,5,6 2 A 31-011 (01-811 1 314" SC NO ND-1 1,3,5,6 3 C 31-011 6'-B" 1 3/4" ND/GL ND-1 1121516 4 c 31-011 0-811 V 1 314" WD/GL ND -I 11-2160 5 A 21-011 (1 0_811 1 314" SC N D ND -I 114 6 A 51-011 (1 0_811 1 314" Sc. N D ND -I 1,4,6,11 7 C 31-011 61-811 1 31411 ND/GL ND- 1 11215/6 DOUIBLE SNING DOOR 8 A 31-011 0-811 V 11 314" 5C NO ND-1 114 q A 51-011 (1 0-811 1 314" SC NO ND -I 1,2,5,6 10 A 31-011 (01 -811 1 514" SC NO ND -I 1,2,5,6 45 MIN C LA5EL DOOR 11 A 31-011 (01-Bil 1 5141, SC NO ND-1 10 POCKET DOOR 12 A 31-011 (01-811 .1 314" SC NO ND-1 1,3,5,6 13 5 (2)21-011 61-811 1 31411 SC NO ND -I 114 14 A 31-011 (01-811 1 514" SC NO ND-1 114516 15 C 51-011 61-811 1 B/4' ND/GL ND -I 1,2,7 16 A :21-811 (01-811 1 314" SC: N D ND-1 1,4,516 17 C 31-011 61-81' 1 514" ND/GL ND-1 11216 is C 31-011 (01-811 1 314" ND/GL ND -I 1/4,5,6 1 q A B1_011 61-611 1 314" Sir- NO ND-1 1,2,(* 201 A 31-011 61-811 1 314" SC, NO ND-1 1,2,6 21 A 51-011 61-80 1 314" SC NO NO-1 126 22 A 31-011 I B/4" SC NO ND-1 11216 23 A B1-011 0-811 1 5/4" 9C NO ND-1 1,2,6 24 A 0-811 1 51411 SC NO ND- 1 1,2,6 25 A 51-011 61-811 1 314" SC NO NO- 1 1 3 516 26 A 31-011 61-811 1 3/4" SC. NO V40-1 126 27 A 31-011 61-811 11 3/411 SC NO ND- I 1 3 5 6 281 5 (2)2'-0" 6'-8'l 1 514" SC NO ND- 1 1,4 2q A 0-811 1 314" S C. NO ND-1 1/416 30 A 0-811 1 31411 SC NO ND-1 1121516 31 A 51-011 ( I 0-511 1 314" SC NO ND-1 1/2,5,6 52 A 51-011 (01-511 1 514" SC NO ND-1 10 POCKET DOOR 35 A 0-811 1 5/4" SC NO ND -I 1,2,6 54 A 0-511 11 5/4" SC NO ND-1 11216 55 A 51-011 61-511 1 514" SC, NO ND-1 1/216 56 A 0_811 1 514" SC NO ND-1 1/2,6 57 A 31 -011 01 -811 1 514" SC NO ND -I 1,3,516 E I EXISTINC, DOOR TO REMAIN. SEE DEMOLITION PLAN, SWEET Al EXIT _101— HARDWARE SCHEDULE 1. 1 1/2 PR. BUTTS PER DOOR LEAF 2. PASSAGE SET 3. PRIVACY SET 4. LOCKSET 5. HYDRAULIC DOOR CLOSER (0. WALL MOUNTED DOOR STOP 7. FLOOR MOUNTED DOOR STOP 6. KICK PLATE BOTH SIDES OF DOOR S. PROVIDE EGRESS HARDWARE 10. POCKET HARDWARE 11, SEE NOTE 5 BELOW NOTES: 1. VERIFY LOCATION OF SPECIAL PIN/COMBINATION DOOR HARDWARE WITH OWNER 2- VERIFY LOCATION OF ALL DOORS REQUIRING VISION PANELS WITH OWNER 3. VERIFY ALL DOOR LOCKING REQUIREMENTS W/ OWNER 4. HARDWARE AT NEW DOORS TO MATCH HARDWARE AT EXISTING MEDICAL SUITE (VERIFY) 5. DOOR SHALL BE HELD OPEN WITH ELECTROMAGNETIC DEVICE AND RELEASED UPON SMOKE DETECTOR ACTIVATION. SMOKE DETECTORS ON BOTH SIDES OF DOOR DOOR AND FRAME NOTES 1. DOOR HARDWARE SHALL BE COMMERCIAL GRADE AND HANDICAP /ADA COMPLIANT AS MANUFACTURED BY SCHLAGE OR APPROVED EQUAL. MATCH CONDITIONS AT EXISTING MEDICAL SUITE 2. CONTRACTOR SHALL COMPLY WITH OWNER'S STANDARD SPECIFICATIONS AND CONFIRM EXACT HARDWARE REQUIREMENTS VERIFY LOCK AND KEYING REQUIREMENTS PRIOR TO ORDERING OF ANY HARDWARE. 3. COORDINATE WIRING OF DOORS WITH OWNER SELECTED SECURITY OR SPECIAL SYSTEMS WHICH MAY REQUIRE SPECIFIC INSTALLATION DETAILS 4. ALL INTERIOR TYPE WOOD DOORS SHALL BE RAISED PANEL W/ WHITE PAINTED FINISH TO MATCH EXISTING INTERIOR DOORS AT MEDICAL SUITE 5. DOOR & FRAMES SHALL RECEIVE 3 RUBBER JAMB SILENCERS, TYP. REFER TO HARDWARE SCHEDULE (b. GC TO COORDINATE W/ MECHANICAL AND ELECTRICAL DRAWINGS FOR SPECIAL CONDITIONS (IE. UNDERCUTTING SWITCHING, ETC) PRIOR TO ORDERING AND INSTALLATION OF DOORS AND FRAMES, TYP. "I. DOOR AND HARDWARE SUPPLIER TO SUBMIT DOOR AND HARDWARE SCHEDULE FOR OWNER / ARCHITECT REVIEW BEFORE ORDERING. DOOR AND FRAME TYPES MATCH EXACT DESIGN OF DOORS AT EXISTING MEDICAL SUITE DECORATIVE I-011 I oil "041 -- 0 11 PAINTED WOOD >- 0 El 11 GLASS FRAMES VISION TO MATCH EXISTING _C0 PANEL co 0 0 0000 011 WD-1 <3> DOOR ELEVATIONS DOOR FRAME TYPES INTERIOR DOORS SHALL BE SOLID CORE WOOD, 6-PANEL INTERIOR WOOD DOOR FRAMES SHALL BE PAINTED WHITE TO MATCH DOORS IN EXISTING MEDICAL PAINTED TO MATCH CONDITIONS IN EXISTING SUITE (CONFIRM WITH OWNER) MEDICAL SUITE (CONFIRM WITH OWNER) FLOOR PLAN KEY NOTES F 1-1 EXISTING INTERIOR WALL TO REMAIN FIRE EXTINGUISHER CABINET SEMI -RECESSED INTO WALL F2] NEW INTERIOR WALL- SEE WALL LEGEND NEW HI-LO DRINKING FOUNTAIN PER CODE REQUIREMENTS DI EXISTING MILLWORK TO REMAIN CONFIRM WITH DENTAL EQUIPMENT MANUFACTURER IF SHIELDING IS REQUIRED AT PANOI 108 Eil NEW MILLWORK- SEE INTERIOR ELEVATIONS EXTERIOR WALLS OF DENTAL SUITE (FRONT, SIDE, REAR): PAINT ALL EEXISTING il ELECTRICAL PANEL TO REMAIN UNDISTURBED- SEE EXPOSED BRICK TO MATCH COLOR OF REMAINDER OF BUILDING. ELECTRICAL INCLUDES MASONRY WALL THAT PENETRATES ROOF. FRELOCATED -(. I PLUMBING FIXTURES AS REQUIRED TO MEET SEE DENTAL EQUIPMENT PLANS FOR EXACT LOCATION OF CURRENT ADA CODE REQUIREMENTS OPERATORIES, CABINETS, SINKS, X-RAY, OVERHEAD LIGHTING, ETC. 7] PORTION OF EXISTING MASONRY TENANT SEPARATION WALL TO 22] F CONSULT WITH DENTAL EQUIPMENT MANUFACTURER FOR BE REMOVED AS REQUIRED TO INSTALL NEW 3'-O!'WIDE RATED RECOMMENDED LAYOUT IN ALL DENTAL ROOMS, PREPARE SPACE DOOR IN HOLLOW METAL FRAME. INSTALL PRECAST LINTEL BEAM FOR FUTURE EQUIPMENT BY CONSTRUCTING IN WALL PLUMBING ABOVE NEW MASONRY OPENING. DOOR SHALL BE HELD OPEN LINES, ETC. PER DENTAL EQUIPMENT MANUFACTURER WITH ELECTROMAGNETIC DEVICE AND RELEASED UPON SMOKE RECOMMENDATIONS DETECTOR ACTIVATION. THIS WORK SHALL BE INCLUDED IN — 23] F EXISTING STEP -BACK IN CORRIDOR WALL TO REMAIN PHASE ONE WORK (SUITE W) 51 EXISTING INTERIOR POCKET DOOR TO BE PERMANENTLY LOCKED 241 F INTERIOR WALL TO ALIGN WITH SIDE OF WINDOW OPENING Rq ALIGN WALLS 9 BULKHEAD ABOVE- 8'-2" A.F.F. NEW/ RELOCATED EQUIPMENT BY OWNER u EXISTING EXTERIOR DOOR TO BE PERMANENTLY LOCKED El \,!=�j WALL MOUNTED SINK- STAINLESS STEEL FINISH R12 AC CONDENSING UNITS- SEE MECHANICAL FIXED WINDOW W/ WOOD FRAME TO MATCH DOOR FRAMES- SEE INTERIOR ELEVS Fil EXISTING ELECTRICAL METER LOCATIONS- SEE ELECTRICAL POWER FOR MICROWAVE ABOVE- SEE INTERIOR ELEVS F14] 5 ROWS ADJUSTABLE SHELVING- 19'DEEP R2q METAL ROOF OVER DENTAL SUITE TO BE REPLACED WITH NEW METAL NEW FIXED TEMPERED GLASS WINDOW WITH SPEAK HOLE- SEE ROOF TO MATCH EXACT COLOR AND APPEARANCE OF ROOF AT REMAINDER OF BUILDING (TO BE FIELD VERIFIED). VERIFY CONDITION INTERIOR ELEVS OF UNDERLAYMENT AND PLYWOOD ROOF DECK AND REPAIR/ 39'X 48" CLEAR SPACE IN INDIVIDUAL -USE TOILET ROOM AS REPLACE IF NECESSARY. SUBMIT FLORIDA APPROVAL INFORMATION REQUIRED TO ALLOW IN -SWINGING DOOR (FBC 602.2.3, EXCEPTION 2) TO BUILDING DEPARTMENT PRIOR TO ROOF INSTALLATION WALL LEGEND TYPICAL NEW INTERIOR WALL (U.O.N.) EXISTING EXTERIOR MASONRY 3 5/8" 22 GA. METAL STUDS AT TYP NEW 6" MTL STUD WALL 77-7-7-777r= WALL TO REMAIN 16" O.C. W/ 5/8" GYP. BOARD EACH SIDE. PROVIDE NEW CONSTRUCTION INTERIOR I EXISTING INTERIOR MASONRY SOUND BATT INSULATION BETWEEN STUDS AND USE PLUMBING WALL- 6" 22 GA. METAL WALL TO REMAIN MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS STUDS AT 16" O.C. W/ 5/8" GYP. BOARD AND HIGH HUMIDITY AREAS TYP. WALL TO EXTEND 6" EACH SIDE. SOUND ATTENUATION EXISTING INTERIOR FRAMED ABOVE FINISHED CEILING AND BE BRACED TO INSULATION FULL HEIGHT OF WALL. WALL TO REMAIN STRUCTURE ABOVE. NOTE: SOUND ATTENUATION USE MOISTURE RESISTANT GWB AT ---- INSULATION TO OCCUR AT ALL INTERIOR PARTITIONS. ALL WET WALLS AND HIGH HUMIDITY EXISTING WALL TO BE INSULATION SHALL EXTEND FULL HEIGHT OF WALL AREAS. REMOVED (U.O.N.) 'r FRAMING (ABOVE CEILING LEVEL). SEE 1/A3 .�4N A,: PAP 00"ON ?1 ON 100 P.9 a 0, k PROVIDERS 0 0 0 EXIST TOILET 4 log, �4 � &q I A�111111111 0 F-Io7l ll� '0 ILY :2] EXAM 2 2t55 41�7\ !M1 MILVA M��=� I ONE= El-T 1111 0 V COMMUNITY FAMILY SERVICE NURSES 115 STATION AF-5 I ADM IN. 107 FAMILY CORRIDOR N EXAM 6 OR 1 245 1 'I CLEAR 15 q ffiMi ire LT DENTAL WAITING FAMILY EXAM 8 FAMILY CORR M EXAM 7 F _16- I PIE ll� T - - - - - - - - - - - - - - - - - - - Fo-1 Fo-1 — — — — — — — -- — — — — — — — — EXIT F-16-1 11� FAMILY EXAM 1 EXISTING 5ULKPEAD A50VE EXIST OFFICE 2 A& Fl 07 GENERAL NOTES 1. ALL DIMENSIONS ARE TO FACE OF INTERIOR FINISH ON 4. NOTE: SEE SHEET A5 FOR INTERIOR ELEVATIONS MASONRY (EXPOSED MASONRY OR GWB) AND TO FACE OF METAL STUDS (U.O.N.) 5. NOTE:VERIFY ALL EXISTING DIMENSIONS. NOTIFY 2. PROVIDE Y4" PLYWOOD BACKING AT ALL PERMANENTLY ARCHITECT OF ANY DISCREPANCIES BETWEEN ACTUAL INSTALLED WALL MOUNTED FIXTURES, INCLUDING CONDITIONS AND THE INFORMATION BEING CABINETS, SHELVING, FIRE EXTINGUISHERS, TOILET REPRESENTED IN THESE PLANS. ACCESSORIES AND PLUMBING FIXTURES 6. REFER TO ENGINEER DRAWINGS FOR ALL LOCATIONS OF MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS NOT 3� SEE SECTIONS 3 AND 4, SHEET A3 FOR RECOMMENDED SHOWN ON ARCHITECTURAL FLOOR PLANS, TYP. MILLWORK CONSTRUCTION EXIT EXIT ELE F131 F;.1 11 /7 77 7 777.7 7777--7= -77 P= F_T_T7 I I LJ [I I I I I I ff- Ill 1171111 1111! 11 1 1 1 1 1 1 1 1 1 1 1 1 F 7 77 1 LLI 11 1 1 7_1 I I I I I L::il III LII I I I I I I I I I I I I I FE - 5167 41IF-15-1 111� ELEC _j L_ PRCVID ELEC, ,LRS PRO RS EDIAT C EXIST OFFICE 2 AL 22 EX 7 OFFICE 1_ 10, EXIST IT UTILITY C 7 F228 a V 22 F22q 17�c U 211 25 F-2-2-i -1 ET2E PEDIATRIC U :3 )1� Lt� L t 4 F2_0_1 EXAM 6 PADIATRIC L EXAM 5 EXISTING F 8� BULKHEAD Al -All CO RIDOR G Fin CORRIDOR J ABOVE 7 23 V40RK COUNTER N/ STOR ABOVE H-� s-E E I V /Z/j MED Z/777 41-01 5TOR SUPPLY Lo IT 11 U —A Sim 4 CLR F225 "-12 ADA I XIST ADMIN OFFICE 1101 OFFICE MANAGER 2r N X EXIST 22"D CORR F F713 14 10, %91 PEDI IC OFFICE 1 1-51 TALLSTORAGE L2 CORR DIRTY &0 2 lip /Y\ U7 SINK 15- 31-011 125 1 p I I PEDI 41-011 q E-26-] NURSES STATION VITALS LAB 128 1� U.t. Ktt- Fil z REF BLOOD F-29-1 NEWBORNS WATER 4F-21-] DRAW BOTTLE CLEAN EXISTING SINK r 4 F3 07 FAMILY I I BULKWEAD 41-011 1 I—NEPq AL ADMIN I I ABOVE AL L COPY I / 1 -31 1 2 PEDIA EXAM 9 1 1 1 12 CLR I ------- 4 EXA 3 CORRIDOR E 25 3� W�7 EXISTING 41-011 \1 CORRIDOR P /0 5ULKHEAD ABOVE EXIST EX15T KIDS I I STOR \EV 31-0" PLAY AREA EXISTING I I 20q Zz�j_ _:Z4 ZI 20 TOILET 1 PEDIATRIC PEDIATRIC EXAM 2 EXAM 1 EXPANDED EXISTING EXISTING FA I LY PEDIATRIC VITALS WAITING I --------------- ----------------- ----------------------------- EXIT WAITING 1,0 -------------------------------------------------------------------- Fo-1 NEW COMSTRUC I IUN LUUH SCALE: 5/16" = V-011 N Issue Date 09-03-21 d C co to :E '0 C, lu- ZM CLLL E C 00 0 00 M (D 0-0 M 0 w d C '0 L_ Cn 0 C: 0 LL 0 L. (D cl� > 0 -C a) U Q_ ry = (1) a) N 4_j CD U) —17 0 cu a) < cu E 0 Job Number 2008 Revisions Z� Z� L Sheet No. A2 �f 1, It LL-1 L 11 ROOF: DECK 12 GA. SUSPENSION WIRE PER MANUF. ABOVE- SUPPORTED FRDM STRUCTURE HEIGHT VARIES- A50VE 12 GA, WIRE BRACING TO STRUCTURAL JOISTS OR DECK ABOVE AT 4S" O.C. AND SECURE TO T PRIOR TO APPLYING NEW CARD ON STUDS GC' MAY ALSO USE MTL STUD BRACING AT W-O" O.C. MA>e_ IN LIEU OF WIRE AT SMOKE PARTITIONS- EXTEND METAL STUDS AND GW5 ON ONE SIDE OF WALL TO BOTTOM OF ROOF DECK- �j Gr- TO FIELD VERIFY ALL AS-5UILTS ROOF DECK CONDITIONS EXTEND WA 61, MIN. A5cLL )Vf-= �'jCEILING (UON) L SUSPENDED 2 X 2 ACOUSTICAL CEILING SYSTEM R-IS BATT INSULATION OVER CEILING TILES TO MATCH EXISTING CONDITIONS Gc TO PROVIDE 5/8" GYP. BOARD, PAINTED PLYWOOD BACKING AS REQUIRED AT ALL LOCATIONS WHERE UF10ER CA5INETRY, EQUIPMENT, MONITORS, ETC. SHALL REQUIRE I.. CNA 3" SOUND BATT INSULATION STRUCTURAL (STC-50 MIN.) -SEE WALL SUPPORT, TYP. TYPES 3 5/8" METAL STUDS 22 GA. 0 16" O.C. WITH 5/8" GYP. 50ARD EACH SIDE, TYP. 3 5/8" OR 6" FLOOR TRACK ANCHORED INTO CONCRETE WITH .11-1 DIAM HILTI POWER ACTIVATED FASTENER UJ/ 3/411 EM5EDMENTs 2411 O.C. 4" BASE - SEE PLAN o EXISTING CONCRETE SLAB 4 .4 INTERIOR WALL SECTION -011 31411 11 10156 S.F. OPEN ATTIC EXIT 60'-0"= DISTANCE BETPqEEN TNO FURTHERMOST 'POINTS IN SUITE �j 6d E Ism w w 11112 �Ip' INN �COUSTICAL SOUND 5ATT �ETWEEN STUDS 5/5" METAL STUDS AT Iro" O.C. kND 5/6" GYf=. 5D EACH SIDE, Yf=. INE OF WALL AT COWERS )ECORATIVE WOOD CASING AND RIM- MATCH PROFILE OF TRIM �T EXISTING ADULT DENTISTRY UITE )OOR-REFER TO DOOR SCHEDULE OTE: ALTERNATE NO.1 IREHUNG INTERIOR DOOf;R5' AND RAMES THROUGHOUT. ALL DOORS HALL BE 6-10ANEL SOLID CORE )OORS. NO HOLLOW CORE FLUSH 1OOD DOORS THROUGHOUT > Uj -J. w Z w w 'In �N �ER! �O F R A�M E� B S�E��I�ET _�D� _�. �A S L 5 � 9 r I 0� CA E AL VERIFY CUT AND PATCH REQUIRED EXISTING CONCRETE TRENCH SLAB. BACK -FILL V41TH V41DTH 3000 PSI CONCRETE �r' 4 #3 X 16" DOWELS 02411 O.C.- EXTEND MIN 61' INTO EX. SLAB AND EPDXY GROUT BOT14 SIDES OF SLAB CUT - EXIST CONC SLAB N/ SCHEDULED FLOOR FINISH REPLACE AND BEAL JOtNTS OF VAPOR IN -FILL TRENCH V41TH ENGINEERED FILL AND BARRIER TO MATCH COMPACT TO q5% DENSITY EXISTING AB �FIL �DET�AIL... SL L 9 �C: A �E _0 1 11504 S.F.1 OPEN 4TIC. Em EXIT FAMILY XAM 4 F Col r_2 FAMILY\// EXAM 3 rnPR K �H, TYP. CLEAR > w _j w t- z w Uj CD VER��ED��A�BINE�T L �A �F BUILDING OCCUPANCY MEAN$ OF ECARF-55 NO. OF OCCUPANTS IN BUILDING WAITING ROOMS- 800 SF/15 - 54 BREAK ROOMS- 244 SFA5 - 16 REST OF BLDG &cJlf SF/50 - 41 TOTAL a Ill EGRESS WIDTH REQUIRED EGRESS WIDTH PROVIDED Ill x.2 x 24" 2t%lf MINIMUM NO. OF EXITS REQUIRED 2 NUMBER Or- EXITS PROVIDED NOTE: MILLWORK ELEVATIONS AND SECTIONS HAVE BEEN DRAWN AS A GUIDE AND ALL DESIGN TO BE VERIFIED V41TH OWNER PRIOR TO FABRICATION. PROVIDE SHOP DRAWINGS WITH SPECIFIC DIMENSIONS FOR FABRICATION CONFORMING TO OWNER'S APPROVED DESIGN AND SPECIFICATION CRITERIA TYP. (UON) MILLV40RK MANUFACTURER SHALL COMPLY WITH AV41 CUSTOM GRADE FABRICATION STANDARDS IF NO OWNER SPECIFICATIONS AVAILABLE ALL CA51NET DRAWERS AND DOOR FRONTS SHALL BE PRES550ARD W/ PLASTIC LAMINATE FINISH, TYP. ALL CA51NET BASES TO BE IN MATERIAL THAT SHALL WITHSTAND DAILY MOISTURE FROM FLOOR CLEANING AND APPLICATION OF SURFACE FINISH SHALL BE APPLIED TO PREVENT DELAMINATION I TYP. ALL CA51NET DOORS, DRAWER FRONTS, EDGE ]BANDING, AND EXPOSED OUTSIDE SURFACES TO HAVE PLASTIC LAMINATE FINISH (UON) ALL INTERIOR CABINET SURFACES TO HAVE MELAMINE FINISH. GC TO PROVIDE OWNER LAMINATE SELECTIONS PRIOR TO FABRICATION LIFE SAFETY NOTES 1, ALL DESIGN CRITERIA, INCLUDING MEANS OF EGRESS CALCULATIONS (OCCUPANCY LOAD) AND CODE REFERENCES, IS SHOWN UNDER PROJECT DATA! ON SHEET Al. 2- THIS PROJECT ENCOMPASSES A MODIFICATION PER FLORIDA FIRE PREVENTION CODE (FFPQ 6TH EDITION. TO INCLUDE NFPA 1 AND NFPA 101 a FIRE E"NGUISHER CABINET LOCATIONS SHALL BE AS INDICATED ON LIFE SAFETY PLAN (FE) 2A MC EXTINGUISHER RESIGNATION. NOTE MAXIMUN TRAVEL DISTAW-E FROM ANY PONT IN BUILDING TO EXTINGUISHER SHALL NOT EXCEED 75 FEET� PER FBC SECTION 906 4. IF APPLICABLE ALL AUTOMATICALLY OPERATED DOORS SHALL BE CONNECTED TO BUILDINGS FIRE ALARVV FIRE PROTECTION SYSTEM AND SHALL AUTOMATICALLY RETURN TO OPEN POSITION UPON FIRE ALARM ACTIVATION OR POWER OUTAGE (BATTERY BACKUP) FIRE PREVENTION NOTES NIMUM 2AI05C RATING I. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH Mi NOTE ALL 2. EVERY EXIT DOOR SHALL BE OPENA15LE FROM INSIDE WITHOUT A KEY OR SPECIAL KNOWLEDGE CONSTRUCTION SHAI L 3. EXISTING EXIT SIGNAGE SHALL COMPLY WITH FLORIDA BUILDING CODE AND ALL APPLICABLE COMPLY V41TH T�­IE STANDARDS. FLORIDA FIRE 4. AS, REQUfRED THE CONTRACTOR SHALL PROVIDE AND INSTALL 5 LB. ABC FIRE EXTINGUISHERS, PREVENTION CODE SURFACE MOUNTED, PER FIRE MAR-844ALL'S INSTRUCTIONS TO MEET CODE MINIMUM (FFPC), 6TH EDITION 5. PROVIDE ACCESS BOX FOR FIRE DEPARTMENT (FIFFE MARSHALL APPLJCATIONS) S.F. df-EN ATTIC: FAMILY EXAM 2 FAMILY EXAM 1 CORRIDOR J EXIT NOT : THIS 15 NOT AN AMBULATORY CARE FACILITY AS DEFINED IN THE 2020 FLORIDA BUILDING CODE, 7TW EDITION, SECTION 202 GENERAL MILLWORK NOTES L SEE DETAILS FOR TYP. CA51NET CONSTRUCTION 2. VERIFY ALL DIMEN51ONS BEFORE FABRICATING CABINETS. NOT - PAY SPECIAL ATTENTION TO ENSURE ADA REQUIREMENTS ARE MET (12" CLEARANCE FROM DOOR TO CABINET ON PUSH SIDE / 18" CLEARANCE ON PULL SIDE). 1/4HEREVER THERE 15 A V40RK COUNTER (OPEN BELOW) THERE SHALL BE GROMMETS FOR THE PASSAGE OF COMPUTER ELECTRICAL HIRING. 4. AT ALL WORK COUNTERS AND CANTILEVERED CUSTOMER COUNTERS, SUPPORTS SHOULD BE INSTALLED AS REQUIRED TO ACHIEVE A STABLE CONDITION. SUPPORTS MAY NEED TO BE ADDED FROM CONDITIONS SHOWN ON DRAWINGS. 5. BASE CABINETS - THERE SHOULD BE AN ADJUSTABLE SHELF AT SINK LOCATIONS, PER THE PLANS. 6. PLASTIC LAMINATE EDGE BANDING TO MATCH CA51NET COLOR. 7. PLASTIC LAMINATE FINIsHE9 (COUNTERTOPS AND CABINETS) TO BE COORDINATED WITH INTERIOR FINISHES SELECTED BY OWNER. COORDINATION BY OWNER 8. FULL OVERLAY EUROPEAN CONCEALED HINGES V41TP 120 DEGREE OPENING q. FULL EXTENSION HEAVY DUTY DRAWER GUIDES. 10. %MM 5RUSHIED CHROME BACK MOUNTED V41RE PULLS 11. 314" 51RC14 PLYV400D CORE COUNTERTOF15 BUILT UP TO 1 1/211 ON ALL 4 EDGES 12. SQUARE EDGE PROFILE ON PLASTIC COUNTERTOPS AND BACKSPLASWES 13. VERIFY LOCKING REQUIREMENTS V41TW OWNER 14. MILLV40RK CONSTRUCTION SHALL BE OF SUPERIOR QUALITY AND COMPLY V41TH AWI CUSTOM GRADE STANDARDS SAFETY GLAZING NOTE TEIVIPERED/SAFETY C4ASS SHALL BE INSTALLED PER FBC 24064 HAZARDOUS AS FOLLOWS�. I IN ALL CLASS PANaS WITHIN SWIGING DOORS 2 IN ALL WINDOW LOCATIONS WITHIN 24' OF DOOR WHERE THE BOTTOM -IF OF THE WINDOW IS 60* OR LESS ABOVE FINO D FLOOR 3L GLAZING THAT MEETS ALL OF THE FOLLONING CRITERIA a. EXPOSED AREA OF INDIVIDUAL PANE IS 9 SQUARE FEET OR MORE. b. BOTTOM EDGE OF GLAZING IS LESS THAN 1W AFF TOP EDGE OF GLA7JNG IS GREATER THAN W AFF d ONE OR MORE WAL" SURFACES IS WITHIN 36' OF THE PLANE OF GLAZING 201411 $.F. OPEN ATTIC I KE r -------- 1 L --------- 1000, 000 PRCi��qtRS Ole 000 i --TOILETI'1� 001 PRO��RS �=) PEDIAT OFFICE 2 C EXIST OFFICE 1 OP 7 0-1 EXAM F0 UTILITY F_2_2_q_j cu, EXIST IT 0-0 EDIATRIC L EXAM 6 PADIATRIC Fj LL ------- ----- EXAM 5 EXIST EXIST ------- -- U�1_ OFFICE 2 OFFICE 1 FAMILY EXIST EXAM 5 -AMILY TOILET 5 VITALS NURSES I U STATION I F24q L 11 FAMILY SCALE EXAM 9 000 00* 4 000 FAMILY C� 000 EXAM 6 1 1 00, 0.0 CORR IN 1 00, 0-10 'CORRIDOR P 000 0-� 0#0 .00 .000 0-0 000 i 14 A VZ111411 "011 FAMILY 00 FAMILY .000 EXAM 8 EXPANDED 000 %1_011 DISTANCE .00 ---- IL t EXAM 7 .00 250 1000 1, 1 FAMILY 00, BETV4EEN EGRESS 00 ()1 CORR M F_E_ 00 t, EXITS (65'-0" MIN WAITING 000p A 001 00* LLOV4EID) F255 1 2471 .000 F ------- ��j_ EXIT F.E.- FIRE EXTINGU HER I� A41 11"tIll] OFFICE 00 MANAGER r_2 EXIST ADMIN OFFICE 0.10 000 a-7-5 oe 000 wo� 000 L-L 17.0 .00 ///44/1 -- 000 �; ;W. 000 �;r� L 130,-0,, DISTANCE RECEPT/ 5ETPqEEN TV40 ADMIN FURTHERMOST ETPOINTS IN SUIT 'T T 0.10 10* .00 000 CORRIDOR G_ L - - - - - - - 0-1 Owl 000 .00 000 010 .*1 .00 �' [ ------- X A -TIED SUPPLY 4 L -------- TOILET 2, C RRF PEDI IC \�' 2- 11 " n.. RH PEDI NURSES STATION LAB p BLOOD F.E] DRAW NEWBORN L------- p . - 7 --i-7-1 ---------- -------- _'7 ------ CORRIDOR E MAX. TRAV DISTANCE TO EGRESS EXI (21'-0' -------- //xz/zzz� KIDS STOR PLAY AREA EXISTING01 F_2_07q TOILET 1 PEDIATRIC PEDIATRIC NOTE: EXISTING MASONRY EXAM1 EXAM 2 ED V4ALLS PENETRATE ROOFLINE EXISTING EXISTING AND SERVE AS SMOKE PEDIATRIC VITALS BARRIERS. MAXIMUM ATTIC WAITING N AREA IN BUILDING- 2qq1 S.F. (3000 S.F. ALLOV4ED) 2. F. LIFE SAFETY PLO SCALE- 5116" - 4011 1 Issue Date 09-03-21 6 V. - 89 00 M 0 to- �_l I LL < Z M Z 0. IL :) E c (0 8 �N- OD 0 ch m_ 28 7C: .3 co 0 m 0 0 0 -1-a (D cli cu > _c 0 c cu (1) CL O� (1) a) =3 0 cu < 2! cu 0 4_0 C Job Number 2008 Revisions fteet No. A3 FINISH SCHEDULE GEWERAL FINSH NOTES FNSH CODE • REFER TO WALL LEGEND, PLANS WOR SECTIONS FOR FIN SUBSTRATE. • WHERE TWO OR MORE FINISHES ARE SCHEDULED, SEE FL PLAN, REFLECTED CLG PLAN, OR INT ELEVS FOR EXTENTS, • WHERE TWO OR MORE CLG HEIGHTS ARE SCHEDULED, SEE REFLECTED CLG PLAN. • ONLY FINISH NON PRE —FINISHED ITEMS. VW VINYL WOOD FLOORING,3 VCT VINYL COMPOSITION TILE EP EPDXY PAINT CT CERAMIC TILE GB GYP BOARD C CARPET VB VINYL BASE W WOOD WC WALL COVERING SC SEALED CONCRETE PB PAINTED BLOCK P PAINTED GYP BD PS PAINTED STUCCO ACT USTICAL CEILING TLE NO. SPACE OR ROOM 01: 8 1� Uj (n < rn C) 0 _r z W �_ 5; 0:9 REMARKS 101 ENTRY L055Y VV4 Pq P ACT/f* CLASS 5 1/4/6/7 102 DENTAL NAITING VN V4 P ACT CLASS 5 1,4,6,7 103 ADA PATIENTS CT CT P ACT CLASS C 1/4,6,7 104 CORRIDOR A VN N F ACT CLASS 5 114/(0/7 105 NEV4 OPERATORY I VIAI N P ACT CLASS 5 1/4/6/7 106 NEV4 OPERATORY 2 W4 P4 F, ACT CLASS 5 1/4/617 107 ADMINISTRATION VIAI IN P ACT CLASS C 1,4,6,7 108 PANO VN N R ACT CLASS 5 1/41(ot7 1001 CORR] DOR 5 VV4 N F ACT CLASS 5 1/4/617 110 NEN OPERATORY 3 VN pq F ACT ICLASS 5 114,6,7 III STORAGE VCT V5 R ACT CLASS C 3/4/617 112 NEN OPERATORY 4 VV4 V4 P ACT CLASS 5 1/4/617 115 MECHANICAL VCT V5 P ACT CLASS C 5/4,6,7 114 STORAGE VCT VS P ACT CLASS C 3/416j7 115 LA5/ STERILIZATION VIAI pq P ACT CLASS 5 114,6,7 116 NEV4 5REAK ROOM I VIAI pq R ACT CLASS C 1/4/6/7 117 CORRIDOR C VV4 pq P ACT CLASS 5 1/4/6/7 Ila ELECTRICAL VCT V5 F ACT CLASS C 514/6/7 Ilq ADA STAFF CT CT P ACT CLASS C 11416/7 120 CORRIDOR D VN N F' ACT CLASS 5 1/4,617 121 PROVIDERS VN V4 P ACT CLASS C 1/4jo/7 122 STORAGE 3 VCT V5 P ACT CLASS C 3,4,617 125 COMMUNITY SERVICE vpq Pq F ACT ICLASS C 1/4/617 201 EXIST PEDIATRIC NAITING W4 N R ACT/F CLASS 5 114/6/7 202 KIDS PLAY AREA VV4 pq P ACT/F CLASS 5 114/6/7 203 EXISTING TOILET 1 CT CT P IACT CLASS C 1,4/6/7 204 CORRI DOR E VV4 N p ACT CLASS 5 1/4/(0/7 205 5LOOD DRAN VV4 N R ACT CLASS 5 it4/6/7 206 LA5 VV4 N P ACT CLASS 5 1/4/6/7 207 MED SUPPLY VV4 P4 P ACT ICLASS 5 11,4j6/7 205 PEDI NURSES STATION VN N P ACT CLASS 5 1,4/6/7 20q F-XISTINCx STORAGE VCT V5 P ACT CLASS C 314,617 210 EXISTING VITALS VV4 Pq P ACT CLASS 5 1/4/6/7 211 NEN50RNS VV4 Pq P ACT CLASS 5 1,416,7 212 PEDIATRIC EXAM I VN N P IACT CLASS C 1/41617 215 PEDIATRIC EXAM 2 VN N P ACT CLASS C 1/4/6/7 214 fz'EDIATRIC EXAM 5 VV4 Pq P ACT CLASS C 1/4/6/7 215 PEDIATRIC EXAM 4 VV4 pq P ACT CLASS C 1/416,7 216 CORRIDOR If VN pq P ACT CLASS 5 1/4j(0/7 217 PEDIATRIC EXAM 5 W4 N R JACT CLASS C 1/4,6/7 218 PEDIATRIC EXAM 6 VIAI N f" ACT CLASS C 114/617 2101 ADA TOILET CT CT P ACT CLASS C 114/6/7 220 EXIST UTILITY VCT V5 P ACT CLASS C 5,4/6/7 221 EXIST IT VCT V5 f" ACT CLASS C 5/4,617 a mim m1m MICE 1-91 =&IN 2 5 1001 N ME (0 , , M1101h I ME 1: a I oil mi a7mmill6liffla-ME1 81 0 (IF, +8"4411 AFF +8`+4" AFF -------------- tit - F L --------- 1112 FINISH SCHEDULE (CONTINUED) NO. SPACE OR ROOM < co § z 0 0 0 5� z 2!:� E (r REMARKS 222 CORR I DOR G VN N P ACT CLASS 5 1 ' 4,6,7 225 PEDIATRIC EXAM 7 VN V4 P ACT CLASS C, 1/4617 224 ADA TOILET 5 CT CT P ACT CLASS C 1,4 617 225 STORAGE VCT VB_ P ACT CLASS C 314/617 226 CORR I DOR H VN V4 P ACT CLASS S 1/4/6/7 227 OFFICE MANAGER vpq V4 P ACT CLASS C I A 6, 7 228 PROVIDERS OFFICE 2 VV4 V4 P JACT CLASS C 11416/7 2201 PROVIDERS OFFICE I VN V4 P ACT CLASS C 1,416,7 250 EXIST ADMIN OFFICE vpq N P ACT ICLASS C. 1,4/617 231 CORRIDOR J VN V4 P ACT CLASS 5 1,4,6,7 252 EXISTING OFFICE 1 VV4 V4 P ACT CLASS C 1/4/(0/7 253 EXISTING OFFICE 2 \IN V4 F ACT CLASS C 1/4/6/7 254 FAMILY EXAM I VN V4 P ACT CLASS C 1/4/617 255 FAMILY EXAM 2 VN V4 P ACT CLASS C 1/4/6/7 236 FAMILY EXAM 5 VP4 pq P ACT CLASS C 1/416t7 237 CORR I DOR K VN V4 P ACT CLASS 5 1,4,6,7 238 NEN 5REAK ROOM 2 VP4 V4 P ACT CLASS C 11 4/ 617 25q FAMILY EXAM 4 VN V4 F ACT ICLASS C 114/6,7 240 ADA TOILET 4 CT CT F ACT ICLASS C 1,4,(o,7 241 ADA TOILET 5 CT CT P ACT ICLASS C 1,416,7 242 CORRIDOR L vpq V4 R ACT CLASS 5 1/4/6/7 243 FAM I LY EXAM 5 VN V4 F ACT CLASS C 114/6/7 244 SCALE VN V4 R ACT CLASS 5 1/416/7 245 FAMILY EXAM 6 VN 104 F ACT CLASS C 1,4,6,7 246 FAMILY EXAM 7 VN V4 P JACT CLASS C 1,416,7 247 CORR I DOR M VV4 V4 P ACT CLASS 5 1/416/7 248 CORRIDOR IN VN pq P ACT CLASS 8 1/4,617 2401 FAMILY NURSES STATION VN V4 F ACT CLASS 5 1/4/6/7 250 FAM I LY EXAM 8 VN V4 F ACT CLASS C 11416,7 251 FAMILY EXAM q VN V4 P JACT CLASS C 11416,7 252 VITALS vpq N P ACT CLASS C 1/416,7 255 RECEPT/ ADMIN VV4 V4 P ACT/P CLASS 5 1/ 41617 254 CORR I DOR R VN N f" ACT CLASS 5 1/416,7 255 EXF. FAMILY NAITING VN N F ACT/P CLASS 5 114,6,7 256 ADA TOI LET 6 CT CT P JACT CLASS C, 1,416,7 REMARKS: 1. ALL EXAM ROOM$ USE WASHA5LE PAINT ON WALLS AS MANUFACTURED BY 'BENJAMIN MOORE'- REGAL CLASSIC INTERIOR PAINT, EGGSHELL FINISH OR EQUAL. 2. CERAMIC TILE WALLS TO 46" AFF AT RESTROOMS. EPDXY PAINT ON WALLS A50VE TILE. 3. ALL INTERIOR COLOR SELECTIONS SHALL BE BY OWNER. GC TO ANTICIPATE A 2 -COLOR INTERIOR WALL SCHEME WITH A PRIMARY COLOR THROUGHOUT AND AN ACCENT COLOR AT -SELECTED WALLS. 4. IT SHALL BE THE RESPONSIBILITY OF: THE GENERAL CONTRACTOR TO PROVIDE SAMPLES OF ALL FINISH MATERIALS (INCLUSIVE OF CEILING TILES, FLOORING MATERIALS AND WALL PAINT COLORS) TO OtLNER FOR FINAL SELECTION BEFORE ORDERING AND INSTALLING SUCH MATERIALS. ROOM FINISH NOTES: 1. EGGSHELL PAINT FINISH ON ALL INTERIOR WALLS EXCEPT WHERE NOTED OTHERWISE. 2. WHERE VINYL WOOD FLOORING IS SPECIFIED IT SHALL BE AS MANUFACTURED BY 'ARMSTRONG- NATURAL CREATIONS- WOOD PLANK APPEARANCE. PLANK DIMENSIONS SHALL BE APPROXIMATELY 4" WIDE x 3'-0" LONG. COLOR SELECTION BY OWNER. 3. WHERE CERAMIC TILE IS SPECIFIED, IT SHALL BE AS MANUFACTURED BY FLORIDA TILE- HAMLET MANOR, 12"x12". COLOR SELECTION BY OWNER 4� WHERE CERAMIC TILE BASES ARE SHOUN THEY SHALL BE (a" HIGH AND 5HALL MATCH THE TILE ADJACENT TO THE WALL. 5. ALL FLOOR TILE SHALL BE SLIP -RESISTANT, HAVING A COEFFICIENT OF FRICTION (COF) OF .60 OR GREATER (o. WHERE VINYL BASES ARE SPECIFIED, THEY $14ALL BE AS FOLLOWS: 'ARMSTRONG' VINYL COVE BASE- 4" HEIGHT- COLOR AS SELECTED BY OWNER -7. WHERE VCT FLOORING 16 SPECIFIED, IT SHALL BE AS FOLLOWS- 'ARMSTRONG' STANDARD EXCELON- 12" X 12"- FLOORING SELECTION BY OWNER 8. ALL JOINT$ IN CMU TO BE FLUSH WITH MASONRY SURFACE AND APPLIED WITH 5LOCK PRIMER AT EXPOSED INTERIOR CONDITIONS 1b. ALL INTERIOR WALL COLOR SELECTIONS SHALL BE BY OWNER. SEE ROOM FINISH SCHEDULE, REMARK No. 3 10. IT SHALL BE THE RESPONS151LITY OF THE GENERAL CONTRACTOR TO PROVIDE SAMPLES OF ALL FIN15HED MATERIALS AND COLORS TO CLIENT FOR FINAL APPROVAL 5EFORE= ORDERING AND INSTALLING SUCH MATERIALS. ALL RESTROOM AND HIGH HUMIDITY AREAS SHALL RECEIVE MOISTURE RESISTANT GYP. 50ARD (UON) ALL TILED WALL AREAS $HALL BE PROVIDED WITH DENS TILE 5ACKER BOARD, DUROCK SUBSTRATE, OR APPROVED EQUAL GENERAL CEILING NOTES 1. ALL CEILING HEIGHTS ARE TO BE COORDINATED WITH MECHANICAL SUBCONTRACTOR PRIOR TO INSTALLATION. VERIFY DUCT AND EQUIPMENT SIZES TO DETERMINE FINAL HEIGHT REQUIREMENTS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. GCSHALLBE RESPONSIBLE FOR COORDINATION BETWEEN STRUCTURAL AND MECHANICAL COMPONENTS TO ENSURE ADEQUATE DUCT RUNS AND PROPER CEILING SPACE FOR MECHANICAL AND ABOVE CEILING ITEMS. 2, GYPSUM WALL BOARD AT RESTROOM AND HIGH HUMIDITY AREAS SHALL BE MOISTURE RESISTANT GYP. BOARD (LION) ALL TILED WALL AREAS SHALL BE PROVIDED WITH DENS TILE BACKER BOARD, DUROCK SUBSTRATE, OR APPROVED EQUAL 3. VERIFY SELECTION OF LIGHT FIXTURES WITH OWNER PRIOR TO INSTALLATION FINAL LOCATION OF SWITCHES TO BE DETERMINED BY OWNER AND SHALL NOT INCUR ANY CHANGE ORDERS RESULTING FROM MODIFICATIONS OF LOCATION IN THE CONSTRUCTION DOCUMENTS. 4. ALL LIGHT FIXTURES TO BE CENTERED IN ROOM OR ALONG PATH OF TRAVEL (UNLESS OTHERWISE NOTED OR SHOWN ON DRAWINGS) 5. ALL CEILING FINISHES TO BE SUSPENDED ACOUSTICAL SYSTEM W121 X 2' GRID SPACING (UNLESS OTHERWISE NOTED) 6. ALL INTERIOR RECESSED CAN LIGHTS SHALL BE ON DIMMERS, TYP. U.O.N. 7. SECURITY SYSTEM (IF ANY) SHALL BE BY OWNER VENDOR - COORDINATE LOCATION AND POWER REQUIREMENTS 8. GC SHALL USE ONLY ARCHITECTURAL REFLECTED CEILING PLAN FOR LAYOUT OF CEILING SYSTEM AND FIXTURES - GC SHALL COORDINATE W/ MECHANICAL AND ELECTRICAL DRAWINGS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO START OF WORK 9. COORDINATE GRID AND LIGHTS INDICATED ON THIS PLAN WITH ALL EQUIPMENT, INCLUDING X-RAY EQUIPMENT. 10. SEE ELECTRICAL PLANS FOR LOCATION OF ALL EXIT LIGHTS AND EMERGENCY LIGHTS WITH BATTERY BACKUP 11. HEIGHT OF ACOUSTICAL CEILING SHALL BE 8'-4" AFF TO MATCH EXISTING(UNLESS OTHERWISE NOTED). CEILING LEGEND NEW 2x4 LED LIGHT FIXTURE - SEE ELEC. 2x2 LED LIGHT FIXTURE- E] SEE ELEC. 0 RECESSED CAN LIGHT- DIMMABLE- SEE ELEC. F712x2 SUPPLY AIR- SEE MECHANICAL 2x2 RETURN AIR- F71 SEE MECHANICAL NOTE: SEE ELECTRICAL FOR LOCATION OF EXIT LIGHTS AND EMERGENCY LIGHTS. CEILING SPECIFICATIONS 1. 24" x 24" ACOUSTICAL CE [LING TILE SHALL BE AS MANUFACTURED BY'ARMSTRONG - DUNE #1774 ANGLED TEGULAR 15/16" CEILING WITH PRELUDE XL 15/16" EXPOSED TEE OR EQUIVALENT TO BE APPROVED BY ARCHITECT 2. AT GYP. BOARD CEILINGS AND SOFFITS THE PAINT COLOR IS TO MATCH THE COLOR OF THE ACOUSTICAL CEILING TILES (OFF-WHITE) 3. AT STUCCO/ PLASTER CEILINGS THE PAINT COLOR IS TO MATCH THE COLOR OF THE ACOUSTICAL CEILING TILES (OFF-WHITE) REFLECTED CEILING KEY NOTES IF INDICATED ON DENTAL EQUIPMENT PLANS, PROVIDE BLOCKING ABOVE CEILING FOR CEILING MOUNTED TRACK LIGHT OVER OPERATORY- SEE DENTAL EQUIPMENT PLANS. BRACE TO STRUCTURE ABOVE AS REQUIRED TO ACHIEVE SECURE CONDITION. F2] GWB BULKHEAD TO EXTEND 1" BELOW FINISHED CEILING. 1-31 FIELD VERIFY CONDITION OF EXISTING EXTERIOR SOFFIT AND LIGHTS. REPAIR/ REPLACE IF NECESSARY F±1 EXISTING GWB BULKHEAD TO REMAIN UNDISTURBED F-51 INSTALL SOUND INSULATION OVER CEILING, THIS ROOM 1:fl EXIT LIGHT- SEE ELECTRICAL PLANS F 71 T-O" WIDE GWB SOFFIT AT +81-0" AFF- 3 5/8" 22 GA METAL FRAMING BRACED TO STRUCTURE ABOVE F8] T-6" WIDE GWB SOFFIT AT +8'-U'AFF- 3 5/8" 22 GA METAL FRAMING BRACED TO STRUCTURE ABOVE 1-91 PROVIDE BLOCKING FOR TV SUSPENDED FROM CEILING DIRECTLY OVER OPERATORY. SEE ELECTRICAL Fi-ol WALL MOUNTED FIXTURE IN CLOSET. SEE ELECTRICAL WE Issue Date 09-03-21 CO Lo wo Mal Z m Z CL LL 3 10 ; 'ON 0 ci W 0 c: 0 LL cli 0 CL a) N 0 cn (D < cu 0 C a) N E a) Job Nmber 2008 Revisions �All ,%set No. A4 ACCESSORIES LEGEND TOILET PAPER Issue Date 42- MIR 11-01 DISPENSER � 09-03-21 (TO 5E VERIFIED WITH OWNER PRIOR TO SEE ACCESSORJES LEGEND, THIS SHEET MAX WNSTRtICTION) \� ---------- WALL MTD. WALL MIRROR WITH STAINLESS STEEL GRA5 BAR PER EDGE BANDING, 24" WIDE X 36" HIGH, ADA Co�) EQUIVALENT TO B05RICK 15-165 METAL STUDS STANDARD CD in MOUNT 50TTOM AT 40" A.F.F. URINAL BEYONR TYR 4w 71-- 98 SURFACE MOUNTED PAPER TOWEL 02 HO URINAL -4e" X Sea" CLEAR FLOOR :E DISPENSER PROVIDED AND SPACE AT WATER CLOSET GRAB BAR FLANGE UNISEX (1-1 z to INSTALLED BY OTHERS wc wC STANDARD WC- W-C" TURNIWG Z CL U. HC- GRA5 5AR, EQUIVALENT TO n E 15015RICK 45-62al SEE FLOOR PLAN RADIUS PER C WC LAV -:3 ADA GRAB BAR BY BOBRICK qz-, 4) 00 TOILET PAFeR DISPENSER f;mr-EssEo MODEL 8W660 OR EQUAL 8" e-- OD 09, M-M INTO WALL. PROVIDED AND INSTALLED 5Y OTHERS. GC TO INSTALL 5LOCKIW-s 4 b J b 30" X 40" CLEAR 2 X 6 WOOD BLOCNNG AS REQUIRED FLOOR SPACE AT SPANNING BETWEEN STUDS WALL SIG 0- SPENSER, jj LAVATORY A 1/32in. RAISED SANS -SERIF UPPEFCASE CHARACTERS SURFACE MOUNTED SOAP 01 LINE OF FIN. FI-R.-j PROVIDED AND INSTALLED 15Y SOAP ACCOMPANIED BY GRADE 2 BRAILE CHARACTERS MIN. 5/&n. HIGH. 0 OTHERS. Ga To INSTALL 5LOCKING AS DISPENSER W1 2- X 1/4' #20 MACHINE REQUIRED L MIRROR A15OVE SCREWS (3 AT EA FLANGE) B, C(XOR BACKAG90UND TAUPE TYPE/FIGURE: WHITE (COLORS TO SURFACE MOUNTED TOILET PAPER TYPICAL MOUNTING HEIGHTS BE NON --GLARE FINISH DISPENSER PROVIDED AND SURFACE MOUNTED =a SIMPSON WOOD SCREWS INSTALLED 5Y OTHERS. NOTE USE PAPER TOWEL C. MOLINTING3 HEIGHT: CENTER OF SIGN TO BE 5 FEET ABOVE THE SURFACE MOUNTED EQUIPMENT AT 3/8* = f-O" DISPENSER C��L) 5Y OTHERS. GC TO SDS 1/4! X 3 W FLOOR ON THE WALL - LATCH SIDE INSTALL SLOOKIN64 (3 TOTAL EACH SIDE OF RATED OR MASONRY WALLS VERIFY AS REQUIRED BLOCKNG TOENALED UPWARD) D MOUNTING METHOD DOUBLE STICK FOAM TAPE, SCOTCH BRAND THAT EQUIPMENT DOES NOT CONFLICT %= WITH CLEARANCE REQUIRED FOR NOTE: FINAL PLASTIC LAMINATE NOT : IT SHALL BF THE L-0 w ACCESS151LITY SELECTIONS SHALL BE MADE BY RESPONSIBILITY OF THE GENERAL UNISEX / ACCESSIBLE SIGN 2X VERTICAL WOOD BLOCKJNG E THICKNES& 1/4 INCH ONNER CONTRACTOR TO OBTAIN FINAL ON CORRIDOR SIDE OF INSET IN METAL STUDS BETWEEN APPROVAL FROM CLIENT OF ALL FMSTROOM DOOR SUPPORT AREA F FABRICATION METHOD MEW PLE)(IGLAS SIGN WITH SURFACE MILLNORK INDICATED ON INTERIOR C40PHCS AND BACK SPRAYED ELEVATIONS PRIOR TO GL APPLICABLE CODER ADA SECTION 4.1Z 4-30A 4.30,5,4.30.6 FABRICATION/ INSTALLATION OF SUCH MILLNORK, TYP. L GED�R�EST�RO�OM�.. R �AB �BA �RD �ET �Al L S � �OM�S I C�N A �GE 3 3 ALL WAI-1-6- CERAMIC TILE 1/4" CLEAR TEMP. C fLASS UT14 I" ALUM. WAINSCOT TO 45" AFF FRAMES ALONG HEAD AND JAMI5. FRAMEL986 GLASS WIT14 SMOOTH EDGE NOTE SEE ACCESSORIES LEGEND SEE INTERIOR DEStraN OMS ALONG SOTTOM. CZNTER Or 4" DIAtL SPEAK FOR FINISHES HOLE SHALL BE W A5OVr= PATIENT C4OUN?ER CENTER OF 4" DIAMETER SPEAK HOLE (NO COVER REWRED) F WALL MIRIQOR WITH SHALL BE *-S" AFF STAINLESS STL EDGE z MANDING 24*111 X 36"H ADA ACCESSIBLE LAVATORr. - NOTE PR40VIDE WEAVY-DUTY ANCHORAGE OF ALL SINKS TO SUIRVACE MTO SOLIND 5LOCKJw-1 INSIDE SOAP DISPENSER OPEN FRAMED WALLS AS RECUIRED TO PIMVENT DETACWENT SUIRFACIE MOUNTED 12" HC GRAI5 ISAR- PAPER TOML TYP 0 IsPaNaeR a �wo //Y 06 �ZID -23 Q0 Q0 co Q0 OPEN OPEN cn 0 FZi Ja HC AAr.C-ESSISL 0 UATER CLOSET E 5'--0" CLEAR PROVIDE INSULATED 3-DRAUIER 16- 3-DRAUr-R OFFSET GRID TRAP CA51NET T� CA13HET -7 (D cli PER CODE AT ALL HANDICAP AWESSIDLE LAVATORIES ENTRY > -c A fr`% A A 1 0 L- ADA RESTROOM LOBBY/101 CORR B/ 109 10 ADMIN/ 107 NOT USED NOT USED C >1 I cu 6 1/4" f-0" 1/4" T—O' 114" = f-0" Elyl,14' T- --L'% N� a) CL 1/4' = f-0" 114 =T-0-'k"L W (1) a) N -00 EQ 01 2'-6" 11 LEQ LEO t.. 6 EQ SPACES CIO 301, WIDE X 6' (D 201, HIGH 4 EQ SP 5 E0 SP 2 E0 SID L, L, 4'-0" 3 EO SP 4'-0" 3 EQ SP EO SPACES 6 E0 SP OPENING3 FOR e- -7 0 MICROWAVE- 4- PROVIDE --N 0 T POWER z —\Z- >% '�- --/7 Z- -.SL- T cn C\j 7 T b Zo \LAI \L A/ \I\J/ \LAI ri-i 1 26 U 111A S \i,11\/i , PL LAM El 11 a) a < ao I] M COUNTERTOF b b 0 it - zo h A NA b T ao T E cu (D t/ Q0 -7F F\ I OPEN OPEN CD 0 a) I cil 17 7 --7'�-- -7 7-- -2K- 2 1� -7 M V 5 E0 SPACES EQ 16' 16 EO y %I %I I I sI I %I 4--0` SPACES SPACES 6 E0 8 E0 16" 16' NEW BREAK 0 ROOM/ 116 PROVIDERS/ 121 TYP EXAM ROOM EXAM ROOM/ 236 RECEPT/253 EXIST ADMIN/ 230 EXIST ADMIN/ 230 EXIST ADMIN/ 230 114- 1= .1-0. 1/4" F-0" r-w Ell-Li/4- N= TV-0- 1/4" T-0" EU—L1,-1N4 —T-0- r n 2 EO SP4" 4' 3 EQ SP 3 EQ SP e- 2 EQ SP 8 EQ SP 4 EQ SP E0 SP 6 E0 SP 3 EQ SP 5 E0 SP Job Number 2008 �0 z - - V 7 z T 7 T '7,- - 7'7 7';7 7 iIA W kA U -23 IIJ J/ \IJ/ Al Revisions i CD I zo Q0 (0 1 �0 30 bo zo I �0 Too -23 PL LAM 0 b (0 OPEN OPEN END Q0 -1 1 T T I T 16" 16' EO 16- EQ 16" 16" 16" 16" 16, 16" pDr', DDn EXIST ADMIN/ 230 IDERS 1/ 229 PROVIDERS 1/ 229 PROVIDERS 1/ 229 PROVIDERS 2/ 228 21 PROVIDERS 2/ 228 X'IDERS 2/ 228 16 17 1/4" t—O" Ekl- �,N 1/4" f-0' 14' = t-0- [��W�4-= TV70- 1/4" f-0" J 1/4- 1'-0- T-0- 4 EQ SP 4 EQ SP 4 EQ SP 5 E0 SP 2 EQ SP 4 EQ SP 0 SID 6 EO SP 4— �O -N X. Z- Z- -\k z- - _NS 4�- 2� cli 7 T -7 7V 7`�- c\j F III iJ il't CD 0 CD CD 0 Y- CD �1 I �I I I co -1 �0 - EO - cli c\j cN\1 C\j C\j N UNDER - FIXED 7 7 77� COUNTER CD \d 0 0 ZD Z- 0 1 1 1 1 REF V -7 1 S7 17 ZD PANEL ZD 0 I 5EYOND` cl) N7 L 2'-0- 4 EO SP VER� 6 EQ SP Z-6 T,4 E0 SID 4 EQ S 11 �L5 6 E0 SP VERFY 11 .1 PEDI NURSES PEDI NURSES Sheet No. CTAT CT A T KIM SUPPLY/ 207 SUPPLY/ 207 LAB/ 206 LAB/ 206 LAB/ 206 BLOOD DRAW/ 205 ION/ 208 ION/ 208 ORNS/ 211 23 24 25 28 L, 9 31 A5 1,14 T_.O,, 4 J 1/4- f-0- E�� EPJ-t,/r4'-1 T—O-r F 1/4" f-0" 1/4" t-0' /4- = �T-W 1/4" 1'-0" �1/4- 1*-0" —c W-41 WPER C Ll 44 K7\- ARCHITECTURAL SPECIFICATIONS NOTE: NOT ALL ITEMS ARE APPLICABLE TO THIS PROJECT A. TERMITE CONTROL USE AN EMULSIBLE CONCENTRATE INSECTICIDE FOR DILUTION WITH WATER SPECIFICALLY FORMULATED TO PREVENT INFESTATION BY TERMITES. FUEL OIL WILL NOT BE PERMITTED AS A DIWENT. PROVIDE A WORKI�G SOLUTION OF ONE OF THE FOLLOWING CHEMICAL R EMENTS AND COWENTRATION& PRODUCTS DURSBAN TC AS RECOMMENDED BY MANUFACTURER ALDRIN: 0.596 IN WATER EMUL-90N DELDRN: 05% IN WATER EMULSION HEPTACHLOR 05% IN WATER EMULSION OTHER SOLUTIONS MAY BE USED AS RECOMMENDED BY APPLICATOR AND IF ACCEPTABLE TO ARCHITECT AND LOCAL GOVERNING AUTHORITES. USE ONLY SOL TFEATMENT SOLUTIONS WHICH ARE NOT INJURIOUS TO PLANTING, It 9 ;11 CONTRACTOR SHALL PROVIDE A PERMANENT SIGN NEAR EXJSTI% OR NEW WATER HEATER OR ELECTRICAL PANFI WHICH IDENTIFIES TERMITE TREATMENT PROVIDER PRODUCT USED, TIME AND DATE OF THE TREATMENT SITE LOCATION, AREA TREATED CHEMICAL USED PERCENT CONCENTRATION AND NUMBER OF GALLONS USED TO ESTABLISH A VERIFLA&E RECORD OF PROTECTIVE TREATMENT CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL EARTH ON THE EXTEIROR OF TI-E BUILDI% SHALL NOT BE LESS THAN 6 INCHES IN ORDER TO PROVIDE TERMITE INSPECTION CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST T-0' AWAY FROM BUILDNG SIDE WALLS INITIAL TREATMENT OF TERMITE P0634W AND PROTECTION SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE COMPLY WITH FBC SECTION 1816.1.1 SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED OR FORIVIED BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION HALL BE M%E H PERMANENT METAL OR PLASTIC W WpSJUMSENT PORIVIS T"BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOL AFTER INITIAL SOIL TREATMENT REMOVE ALL CONCRETE OVERPOUR AND MORTAR ALONG THE FOIJINDATION PERIMETER PRIOR TO EXTERIOR TERMITE SOL TREATMENT CHEMICALLY TREATED SOIL FOR SUBTERRANEAN TERMITES SHALL BE PROTECTED WITH A MINIMUM 6 MIL VAPOR RETARDER TO PROTECT AGAINST RAINFALL DILUTOR RETREATIVIENT SHALL BE REQUIRED IF RAINFALL OR DILUTION OF CHEIVICAL OCCURS PF40R TO SOL PROTECTOR ALL BUILDINGS SHALL HAVE PRE -CONSTRUCTION TREATMENT AND PROTECTION AGAINST SUBTERRANEAN TERMFrES LICENSED PEST CONTROL APPLICATOR SHALL ISSUE A CERTIFICATE OF COMPLIANCE TO THE BUILDING DEPARTMENT WITH THE FOLLOWING STATEMENT: M-E BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES TREATMENT IS IN ACCORDANCE WIT�&IES OF UL* LAWS ESTABLISHED BY NE FLORIDA DEPARTMENT AND C04SUMER SERVICER" GC SHALL REMOVE ALL LOOSE WOOD AND FILL FROM BELOW AND WITHIN T-0" OF THE BUILDING, INCLUDING \A= STAKES, FORMWORK, TRAP BOXES, SHORWA OR OTHER CELLULOSE CONTANNG MATERIAL NO WOOD, VEGETATION STUMPS� DEAD ROOTS, CARDBOARID, TRASH, OR OTHER CELLULOSE -CONTAINING MATERIAL SHALL BE BURIED ON THE BUILDING LOT WITHIN 15 FT. OF ANY EXISTING OR PROPOSED BULDING STRUCTURE AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION, ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED SHALL BE RETREATED. SOL TREATMENT SHALL BE APPLIED UNDER ALL EXTEROR CONCRETE OR GRADE WITHIN T-O' OF THE STRUCTURE SIDEWALLS, B. CONCRETE PRODUCTS CONCRETE MIX UNLESS SPECIFIED ON STRUCTURAL DOCUMENT& PROVIDE CONCRETE TO THE FOLLOWING MIX DESSIGNI: COMPRESSIVE STRENGTH (28 DAY) MINIMUM 3000 P.SI. MAXIMUM 2196 FLY ASH OF CEMENT EXAMINATION VERIFY COMPACTED SUBGRADE IS ACCEPTABLE AND READY TO SUPPORT PAVING VERIFY GRADIENTS AND ELEVATIONS OF THE BASE ARE CORRECT Pf:EPARATION MOISTEN BASE TO MINIMIZE ABSORPTION OF WATER FROM FRESH COW -FETE COAT SURFACES OF ALL FRAMES WITH OIL TO PREVENT BOND WITH CONCRETE NOTIFY ARCHITECT MINIMUM 24 HOURS PRIOR TO COMMENCEMENT OF CONCFETIWG OPERATIONS EXECUTION ENSURE REINFORCEMENT, INSERTS, EMBEDED PARTS, FORMED JOINTS ARE NOT DISTURBED DURING CONCRETE PLACEMENT PLACE C)ONICRETE CONTINUOUSLY BETWEEN PREDETERMINED CONSTRUCTION JOINTS DO NOT BREAK OR NTERRUPT SUCCESSIVE POURS SUCH THAT COLD JOINTS OCCUR JOINTS PLACE CONTROL JOINTS AT 10 FOOT INTERVALS (LON) PLACE JOINT FILLER BETWEEN PAVING COMPONENTS AND BUILDING (DR OTHER APPURTENANCES PROVIDE SAW JOINTS AT 5 FEET INTERVALS IN SIDEWALKS SAW CUT CONTRACTION JOINTS 31*6 INCH WIDE AT AN OPTIMUM 11ME UP TO 24 HOURS AFTER FINISHING. CUT 1/4 INTO DEPTH OF SLAB FINISHIW-A STEEL TROWEL PROTECTION IMMEDIATELY AFTER PLACEMENT PROTECT CONCRETE FROM PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURES, AND MECHANICAL INJURY C. COLD FORMED METAL FRAMING PRODUCTS/MANUFACTURERS DALE INDUSTRIES, INC DIETRICH INDUSTRIES, INC ALLSTEEL & GYPSUM PRODUCTS, INC FRAMING MATERIALS STUDS ASTM C955 FORMED TO CHANNEI SHAPE, SOLID WEB GUAGES AS INDICATED ON DRAWWSS, I INCH FACE AND 3 5/8 OR 6 IN. DEEP TRACK, FORMED STEEL, CHANNEL SHAPED, SAME WIDTH AS STUDS, SOLID WER 20 GAGE THICK UNLESS OTHERWISE SPECARED ON PLANS) ACCESSORIES BRACIWA FURRIWA BRIDGING, PLATES GUSSL7S AND CUPS FORMED SHEET STEEL, THICKNESS DETERVINED FOR CONDITIONS ENCOUNTERED FASTENERS SELF DRILLM SELF TAPPING SCREWS, BOLTS, NUTS AND WASHERS, ASTIVI A123, HOT DIP GALVANIZED TO 125 OZ/90 FT ANCHORAGE DEVICES POWER ACTUATED AND DRILLED EXP BOLTS WELDING; N CONFORMANCE WITH AWS D11 AND AWS D13 FABRICATION FABRICATE ASSEMBLIES OF FRAMED SECTIONS OF SIZES AND PROFILES REQUIRED WITH FRAMING MEMBERS FITTED, REINFORCED, AND BRACED TO SUIT DESIGN MQUIREI`V�NITS FINISHES STUDS GALVANIZE TO G90 COATING CLASS TRACKS AND HEADEFe GALVANIZE TO G90 COATING CLASS BRAO�4 FURRINGA BRIDGING, PLATES, GUSSETS AND CUPS, SAME FINISH AS FRAMING MEMBERS D. BUILDING INSULATION PRODUCTS/MANUFACTURERS CERTAINTEED CORPORATION OWENS-CORNING FIBERGLASS CORPORATION ATLAS ENERGY PRODUCTS CELOTE)( ROOFING PRODUCTS INSULATINGG MATERIALS RIGID BOARD PREFORMED UNITS SOUND ATTENUATION BLANKETS: ASTM C 665� TYPE 1, UNFACED MINERAL FIBER INSULATION 3 IN. THICK MIN. STC-50 MIR AT ALL INTERIOR PARTITIONS SPRAY FOAM ICYNENE INSULATION (R-30 MIN) BATT INSULATION: ASTIVI C665, PREFORMED GLASS FIBER BATT, FRIC-nON FIT, R-VALUE OF 11, BATT SIZE 16 X 48 INCH, UNFACED, FLAME/SMOKE PROPERTIES 25/25 IN ACCORDANCE WITH ASTM E84 POLYISOCYANURATE ROOF INSULATION: CLOSED CELL TYPE� 2 LB/CU FT., FACTORY APPLIED FIBERGLASS FACING TYPE Z FLAME SPREAD 25, AND AGED R OF 30 MIN PREPARATION CLEAN SUBSTRATE OF SUBSTANCES HARMFUL TO INSULATION AND INTERFERING WITH ATTACHMENT INSTALLATION INSTALL PER MANUFACTURER'S RECOMMENDATIONS BOND UNITS TO SUBSTRATE WITH ADHESIVE OR MECHANICAL ANCHORAGE TO PROVIDE PERMANENT PLACEMENT OF UNITS INSTALL MINERAL FIBER BLANKETS IN CAVITIES BY FRICTION FIT E. WOOD BLOCKING AND CURBING MATERIALS LUMBER GRADING RULEa NFPA SPIR WCUB, MISCELLANEOUS FRAMING STRESS GROUP D, SPECIES, 19 PERCENT MAXIMUM MOISTURE CONTENT, PRESSURE PRESERVATIVE TREAT PLYWOOD' APA RATED SHEATHING, GRADE C-D, EXPOSURE DURABILITY I SANDED, ACC'ES AW&%A FASTENERS AND ANCI-IORR. FASTENERS HOT -DIPPED GALVANIZED STEEL FOR HGH HUMIDITY AND TREATED WOOD LOCATIONS, UNFINSHED STEEL ELSEWHERE ANCHORR TOGGLE BOLT TYPE FOR ANCHORAGE TO HOLLOW MASONRY EXPANSION SHELD AND LAG BOLT TYPE FOR ANCHORAGE TO SOLD MASONRY OR CONCRETE BOLT OR BALLISTIC FASTENER FOR ANCHORAGES TO STEEL FACTORY WOOD TREATMENT FIRE RETARDANT' AWPA TREATMENT C2A EXTERIOR INTEF40R TYPF, CHEMICALLY TREATED AND PRESSURE IMPREGNATED. WOOD PRESERVATIVE (PRESSURE TREATME": AWPA TREATMENT 01 USING WATER BORNE PRESERVATIVE WITH 0.25 PERCENT RETAINAGE WOOD PRESERVATIVE (SURFACE APPLICATICN� CLEAR TYPE, COMPATIBLE WITH PRESSURE TREATED TYPE SHEATHING SECURE SHEATHING TO FRAMING MEMBERS WITH ENDS OVER FIRM BEARING AND STAGGERED. INSTALL TELEPHONE AND ELECTRICAL PANEL BOARDS WITH PLYWOOD SHEATHING MATERIAL WHERE REQUIRED. OVER SIZE THE PANEL BY 12 INCHES ON ALL SIDES UNLESS SIZE IS CALLED FOR ON DOCUMENTS. PANEL SHALL BE 3kV THICK UNLESS OTHERWISE NOTED E. SHEET METAL FLASHING AND TRIM PERFORMANCE REQUIREMENTS INSTALL SHEET METAL FLASHING AND TRIM TO WITHSTAND WIND LOADS, STRUCTURAL MOVEMENT, THERMALLY INDUCED MOVEMENT, AND EXPOSURE TO WEATHER AND LIQUID WATER WITHOUT FAILING AND WILL WITHSTAND WIND LOADS, THERMALLY INDUCED MOVEMENT, AND EXPOSURE TO WEATHER WITHOUT FAILURE. FABRICATE AND INSTALL FLASHINGS AT ROOF EDGES TO COMPLY WITH FM LOSS PREVENTION DATA SHEET 1-49 FOR WIND ZONE 1 (20-30 PSF) METALS MILL -FINISH ALUMINUM SHEET ASTM B 2D9, 30034M, WITH MINIMUM THICKNESS OF 0.040 INCH, UNLESS OTHERWISE NOTED REGLETS UNITS OF TYPE, MATERIAL AND PROFILE INDCATEDI, FORMED TO PROVIDE SECURE INTERLOCKING OF SEPARATE REGLET AND COUNTERFLASHING PIECES AND COMPATIBLE WITH FLASHING INDICATED. REGLET ACCESSORIES INCLUDE SURFACE -MOUNTED, STUCCO AND MASONRY TYPE PROVIDED BY EITHER FRY REGI-ET, HICKMAN, OR KEYSTONE FLASHING COMPANY. ACCESSORIES FASTENERS ASPHALT MASTIC ELASTOMERIC SEALANT EPDXY SEAM SEALER ADHESIVES, METAL ACCESSORIES, ROOFING CEMENT FABRICATION FABRICATE SHEET METAL FLASHING AND TRIM T COMPLY WITH RECOMMENDATIONS OF SMACNAS 'ARCHITECTURAL SHEET METAL MANUAL! THAT APPLY TO THE DESIGN, DIMENSIONS, METAL, AND OTHER CHARACTERISTICS OF THE ITEM INDICATED FORM EXPOSED SHEET METAL WORK WITHOUT EXCESSIVE OIL CANNING AND BUC-4<1-IW;� AND FABRICATE NON-4VIOVING FLAT --LOCK SEAMS SEALEDwnH EPDXY SEAM SEALER SPACE MOVEMENT JOINTS AT 10 FEET MAXIMUM WITH NO JOINTS ALLOWED WITHIN 24 INCHES OF CORNER OR INTERSECTION LAPPED OR BAYONET -TYPE TO HAVE EXPANSION JOINTS OF INTERMESHING HOOKED FLANGES NOT LESS THAN I INCH DEEP FILLED WITH MASTIC SEPARATE METAL FROM NOWOMPATIBLE ME7AL OR CORROSIVE SUBSTRATES BY COATING CONCEALED SURFACES AT LOCATIONS OF CONTACT WITH ASPHALT MASTIC OR OTHER PERIVIANENT SEPARATOR CCNCCEAL FASTENERS AND EXPANSION PROVISIONS WHERE POSSIBLE EXPOSED FASTENERS ARE NOT ALLOWED ON FACES OF SHEET METAL EXPOSED TO PUBLIC MEW FABRICATE CLEATS AND ATTACHMENT DEVICES FROM SAME METAL COMPONENT BEING ANCHORED PRODUCT MATERIALS RR P TRATION FLASHING LEAD AT 4.0 LB PER SF H TV PERED SCUPPERS. ALUMINUM AT 0.032 INCH THICK EXPOSED TRIMS, GRAVEL STOPS, AND FASCIA ALUMINUM AT 0.05 INCH THICK CXX1NIGS: ALUMINUM AT 0.05 INCH THICK COUNTERFLASHM-L ALUMINUM AT 0.032 INCH THICK DRIP EDGES, ALUMINUM AT 0.05 INCH THICK FINISHES COMPLY WITH ALUMINUM ASSOCATKNS IDESGNATION SYSTEM MR ALUMINUM FINISHES' HIGH --PERFORMANCE ORGANIC COATING FINISH: AA-CVC42RIX PREPARF, PRETREAT, AND APPLY COATING TO EXPOSED METAL SURFACES MANUFACTURERS STANDARD 2-COAT FLUOROPOLYMER SYSTEM TO COMPLY WITH AAMA 6052 COLOR AND GLOSS TO BE SELECTED BY ARCHITECT G, SBS—MODIFIED BITUMINOUS SHEET ROOFING PERFORMANCE REQUIREMENTS INSTALL A WATERTIGHT, MODRED BITUMENCUS MEMBRANE ROOFING AND BASE FLASHING SYSTEM WITH COMPA11BLE COMPONENTS THAT WILL NOT PERMIT THE PASSAGE OF LIQUID WATER AND WILL WITHSTAND WIND LOADS, THERMALLY INDUCED MOVEMENT, AND EXPOSURE TO WEATHER WITHOUT FAILURE, SHEE7 ROOFING AND COMPONENT MATERIALS TO COMPLY WITH UL FOR CLASS A EXTERNAL FIRE EXPOSURE FIM 1-90 WIND UPLIFT CLASSIFICATION, ASTM E 84 AND 119 WARRANTY FURNISH WRITTEN WARRANTIES THAT SHALL COVER ANY AND ALL NECESSARY LABOR AND MATERIAL FOR REPAIR OR REPLACEMENT WORK REQUIRED TO KEEP AND MAINTAIN THE ROOFING MEMBRANE AND MEMBRANE FLASHING WORK IN A WATERTIGHT AND FIRST CLASS CONDITION AT NO ADDITIONAL COST TO OWNER WARRANITES SHALL BE FURNIISHED AS FOLLOWS AFTER THE DATE OF SUBSTANTIAL COMPLETION TWO (2) YEARS BY THE ROOFING INSTALLER TWENTY (20) YEARS BY MANUFACTURER OF ROOFING PRODUCT ONE 0 YEAR BY GENERAL CONTRACTOR SUBMITTALS SHOP DRAWIW�S INCLUDING PLANS, SECTM, DETAILS FOR BASE FLASHINGS� CANTS, MEMBRANE TERIMINATIONS, FASTENING PATTERNS CRICKETS SADDLES AND TAPERED EDGE STRIPS WRITTEN CERTIFICATION FROM ROOFING MANUFACTURER OF MODIFIED BITUIVIENOUS SYSTEM CERTIFYING THAT INSTALLER IS APPROVED BY MANUFACTURER TO INSTALL SPECIFIED SYSTEM SUBMIT CALCULATIONS CERTIFYING THAT BASE LAYER AND INSULATION SYSTEM WILL PROVIDE A MINIMUM AVERAGE AGED R-VALUE OF R20 FOR THE COMPOSITE ROOF ASSEMBLY AR"MA IINARMA'0-102301 SUBMIT CE-RnFICATION BY ROOFNG MANUFACTURER THAT CONTRACT DOCUMENTS ARE ACCEPTABLE TO THEM FOR THE DECK AND SURFACM TO WHICH TI-iEY ARE APPLIED F Cf-7ALS ARE NOT ACCEPTABLE BY MANLIFACTUFEI� SUBMIT PROPOSED CORRECTIVE DETAILS AND REASONS FOR NON -ACCEPTANCE NO DE�VIATION IS TO BE MADE FROM THIS SPECIFICATION WITHOUT PRIOR APPROVAL BY THE ROOFING MANUFACTURER AND SUBMITTED TO ARCHITECT INSPECTION PRIOR TO, DURING, AND COMPLETION OF THE ROOFING INSTALLATION SHALL BE MADE BY A REPRESENTATIVE OF THE MANUFACTURER IN ORDER TO ASCERTAIN ROOFING SYSTEM HAS BEEN INSTALLED PROPERLY ACCORDING TO THEIR SPECIFICATIONS, STANDARDS, AND DETAILS ROOFING SYSTEM AND MATERIALS 2-PLY SBS MODIFIED BITUMEN ELASTOMERIC, ROOFING SYSTEM FOR G[-UE-DOWN INSTALLATION OVER RGD INSULATION. BASE PLY CONSISTS OF SMOOTH SBS RB69GLASS OR POLYESTER RSNIFORCED, 118 MIL THICK MEMBRANF, 80 LBS PER 100 SQUAFE FEET (AVERAGE) CAP PLY CONSSTS OF SBS FIBERGLASS OR POLYESTER REINFORCED, 120 MIL THICKNESS WITH WHITE GRANULAR SURFACF, 90 LBS. PER 100 SQUARE FEET (MINIMUM) FLASHINGS CONSIST OF SBS FIBERGLASS OR POLYESTER REINFORCED, 98 ML THICKNESS MIR, FACED WITH EMBOSSED ALUMINUM FOIL, 90 LBS PE14 100 SQUARE FEET (MIN!") RCOFINGi BITUMENS CONSIST OF ROOFNG ASPHALT TO COMPLY WITH ASTM D31Z TYPE N MANUFACTURERS SIPLAST PARADENE 20/30 FR WITH PARADENE 20 EG BASEAND PARADIENE 30 FIR CAR WITH VERAL ALUMINUM SURFACED FLASH1% SYSTEM APPLIED OVER PARADENE 20 EG FLASHING BASE PLY SCPREMA 2144 FR WITH SOPRALENE 180 SANDED BASE AND SOPPALENE 180 FR GRANULES CAP, WITH SOPRALAST 50 TV ALU ALUMINUM SURFACED FLASHING SYSTEM APPLIED OVER SOPRALENE FLAM 180 FLASHING BASE PLY APPROVED EQUIVALENT NOTE VOIDS AIR POCKETS, RIDGE$, AND WRINKLES SHALL NOT BE ACCEPTABLE AS A FINISHED PRODUCT RELATED MATERIALS WOOD MEMBERS TO COMPLY WITH ROUGH CARPENTRY CANTS PERUTE BOARD ASTM C 728 OR SOLD PT WOOD TAPERED EDGE STRIPS: RIGID PERIJTE BOARD, ASTIM C WALKWAY PROTECTION BOARDS. THICK BITUMINOUS PANELS SUBSTRATE JOINT TAPE 6' OR 8" WIDE, COATM GLASS-FIBM MASTIC SEALANT ASPHALT PRIMER ASTM D41 m- -68- COMPLY WITH INS"TICNI MANLIFACTUTEM WFf rf EN INMWTM FOR TFE STCPAGI� HANDUSIGA tWALLATK)K AND ANCHORAGE OF N&LATION M SLeSTRATE OR DECK H. JOINT SEALERS PERFORMANCE REQUIREMENTS PROVIDE ELASTOMERC JOINT SEALANTS THAT HAVE BEEN PRODUCED AND INSTALLED TO ESTABLISH AND MANTAN WATERTIGHT AND AfITGHT CONTINLCUS SEALS WITHOUT CAUSING DETERICATION OF JOINT SUBSTRATES ELASTOMERIC JOINT SEALANTS COMPLY WITH ASTM C 920 AND CLASSIFICATIONS FOR TYPF, GRADE, GLASS, AND USES SlW;iLE PART POURA&E URETHANE SEALANIT FOR USE T BY VULKEM 45/MAMECO INTERNATICINAL INC. OR APPROVED EQUAL ONE -PART NONSAG URETHANE SEALANT FOR USE NT BY "VULKEM 921'lMAMEC0 INTERNATIONAL INC LATEX JOINT SEALANTS USE 'AC-20"/PECORA CORP. OR 'SONOLAC7SONNEBORN BUILDIW;, PRODUCTS OR APPROVED EQUAL AS TO COMPLY WITH ASTM C 834 ACOUSTICAL JOINT SEALANTS PROVIDE NONSAG, PAINTABLE, NON-STAJNIW3 LATEX SEALANT COMPLYING WITH ASTIVI C 834 FOR CONCEALED JOINTS USE NON-DRYING, NON -HARDENING SYNTHETIC RUBBER SE&k4-f FOR INTERIOR JOINTS JOINT SEALANT BACI'QNG PLASTIC FOAM JOINT FILLERS PREFORMED COMPRESSIBLE, RESILIENT, NON -STAINING MATERIAL THAT IS CLOSED-CFELL POLYETHYLENE FOAM AND NON-ABSORBANT TO LIQUID WATER OR GAS AND COMPUES WITH ASTM D 1623 AND ASTM C 1083 JOINT FILLERS FOR CONCRETE PAVING BITUMENOUS FIBER JOINT FLLER PREFORMED STRIPS OF ASPHALT SATURATED FIBEREIOARD, USE EITHER *RBER EXPANSION JOINT" - THE BURKE COMPANY OR 'TEX-LITE FIBER - J&P PETROLEUM PFIODUCTS INC SPECIFICATIONS GENERAL NOTE: THE SPECIFICATIONS INDICATED ON THIS PAGE ARE ARCHITECTS RECOMMENDATIONS ONLY. NOT ALL ITEMS ARE APPLICABLE TO THIS PROJECT, GENERAL CONTRACTOR TO VERIFY OWNER'S PREFERENCES PRIOR TO ORDERING MATERIALS OR PERFORMING WORK 1. STANDARD STEEL FRAMES PRODUCTS/MANUFACTURERS AMWELD BUILDING PRODUCTS CECO CORPORATION MESKER INDUSTRIES FIREDOOR OF FLORIDA STEELCRAFT MANUFACTURING COMPANY FRAMES INTERIOR FRAMES 16 GAGE THICK MATERIAL, BASE METAL THICMESS ACCESSORIES SILENCEF&' RESILIENT RUBBER FITTED INTO DRILLED HOLE REMOVABLE STOPS: POLLED STEEL CHANNFI SHAPE, MITERED CORNERS, PREPARED FOR COUNTERSINK STYLE TAMPER PROOF SCREWS BITUMINOUS COATING, FIBERED ASPHALT EMULSION PRIMER ZINC CHROMATE TYPE FINISH STEEL SHEET GALVANIZED TO ASTM A525 G60 FOR INITERIOR AND G90 FOR EXTERIOR PRIMER BAKED INSTALLATION INSTALL FRAMES IN ACCORDANCE NTH ANSVSD-100 AND DHI COORDINATE W/ WALL CONSTRUCTION FOR ANCHOR PLACEMENT COORDINATE INSTALLATION OF FRAMES WITH INSTALLATION OF HARDWARE AS SPECIFIED J. FLUSH DOORS (IF APPLICABLE WARRANTY PROVIDE WARRANTY FOR LIFE OF INTERIOR DOORS PRODUCTS/MANUFACTURERS DOOR MERICA - AMERICAN SERIES CRAFTMASTER MASTER CRAFT MASONITE FLUSH SERIES OR EQUAL APPROVED BY ARCHITECT DOOR CONSTRUCTION FLUSH SOLID CORE WOOD NT0:4OR DOORS 1 3W THICK PREFINISHED TO MATCH EXISTING NTEF40R DOORS SUBMIT SAMPLE FOR OWNER / ARCHITECT REVIEW BEFORE ORDERI% K. HARDWARE (IF APPLICABLE PRCIDUCCTS/MANUFACTUIRERS HINGES HAGER, STANLEY, AND MCKINNY PUSH/PULLR ROCKWOOD, HAGER AND IVES CYLINDER LOCKS: RUSSWIN, SCHLAGE AND SARGENT SCHLAGE 'S' SERIES HAGER # M SERES W/ GRADE 2 CYLINDRICAL LEVERS OR APPROVED EQUAL CLOSERR LON RUSSWIR OR SARGENT LCN 1461 SERIES, HAGER # 5200 SERIES OR APPRCVED EQUAL CONCEALED CLOSERS USE LCN, DORMA� RIXSON PANIC HARDWARE- VON DUPRIN OR APPROVED EQUAL VON DUPRIN 22 SERIES WITH PP RIM DEVICE AND 210 NL TRIK HAGER #4700 SERIES EXJT DEVICE OR APPROVED EQUAL OVERHEAD HCLDER& GLYNN-JOHNSON, AND RXSON NO RASTC END CAP ACCEPTED MANUAL AND AUTOMATIC BOLTS� IVES, HAGER AND DO GASKETING: PEIVIKQ DURAELF, AND NATIONAL GUARD PROTECTION PLATER ROCKWOOD, HAGER, AND IVES MOUNTING HEIGHTS HINGE-S US26 LOCKSETS 38 INCH LOCKS LJS26 PUSH/PULLS 42 INCH CLOSERS US26 DEAD LOCKS 48 INCH EXIT DEVICES US26 EXIT DEVICES 38 INCH PUSH, PULL US26 ALL MOUNTING HEIGHTS TO KICK PLATES COMPLY WITH FBC 2001 AND MISCELLANEOUS US26 HANDICAP ACCESSIBILITY REQUIREMENTS L. ALUMINUM ENTRANCES AND STOREFRONTS SYSTEM PERFORNIANCE REQUIREMENTS PROVIDE ALUMINUM ENTRAME AND STOREFRONT SYSTEM CAPABLE OF WITHSTANDING LOADS, THERMAL, AND STRUCTURAL MOVEMENT REQUIREMENTS WITHOUT FALLIFE, BASED ON TESTING MANUFACTURERS STANDARD UNITS. FAILURE INCLUDES: AIR INFILTRATION AND WATER PENETRATION EXCEEDING DESIGN CRITERIA AND FRAMING MEMBERS TRANSFERflNIG STRESSES CAUSED BY THERMAL AND STRUCTURAL MOVEMENT TO GLAZING DESIGN CRITERIA PHYSICALLY AND THERMALLY ISOLATE GLAZING FROM FRAMING MEMBERS AND PROVIDE GLAZING TO GLAZJW;a JOINTS THAT ACCOMMODATE THERM& AND MECHANICAL MOVEMENT AND MAINTAIN EDGE CLEARANCES STOREFRONT SYSTEMS AND ANCHORAGE TO BE CAPABLE OF WITHSTANDING WIND LOAD DESIGN PRESSURES OF 26 LB PER SF AS MEASURED IN ACCORDANCE WITH ASTIM E330 STOREFRONT SYSTEMS TO PROVIDE PERMANENT RESISTANCE TO AIR INFILTRATION OF NOT MORE THAN 006 CFM PER SF OF FIXED WALL AREA MEN TESTED ACCORDING TO ASTIVI E 283 AT STATIC-ARr-DIFFERENCE OF 1.57 LB PER SF STOREFRONT SYSTEMS TO PROVIDE PEI:#VMENT RESISTANCE AGAINST WATER PENETRATION AS TESTED ACCORDING TO ASTM E 331 AT MN DIFFERENTIAL PRESSURE OF 20 PERCENT OF INWARD ACTING WIND LOAD DESIGN PRESSURE, BUT NOT LESS THAT 624 LB PER SF IMPACT - RESISTANT CONDITIONS SHALL BE ACHEVED THROUGHOUT AS REQUIRED BY CODE SEE STRUCTRAL ENGINEERIWG FOR WIND LOAD PRESSURE REOUREMENTS SUBMITTALS PROVIDE SHOP DRAWINGS TO SHOW DETAILS OF FABRICATION AND INSTALLATION, INCLUDING PLANS� ELEVATIONS, SECTIONS AND DETAILS NTH PROVISIONS FOR THERMAL EXPANSION PROVIDE STANDARD CCLOR CHART FOR SELECTION BY ARCHITECT TEST REPORTS BY AN INDEPENDENT TESTING AGENCY TO SHOW COMPLIANCE WITH THE ABOVE WRITTEN DESIGN CRITERIA WARRANTY SUBMIT WRITTEN WARRANTY EXECUTED BY THE MANUFACTURER AGREEING TO REPAIR OR REPLACE COMPONENTS OF ENTRANCE AND STOREFRONT SYSTEMS THAT FAIL IN MATERIALS OR WOWMANSHIP WITHIN THE MANUFACTURERS STANDARD WAFRANTY PERIOD PRODLCTS/MANUFACTUIRERS ARCH ALUMINUM AND CLASS 00, \AESTSHORE GLASS CORP EFCO IW. YKK AMERICA, INC. KAWNEER OR APPROVED EQUAL RELATED MATERIALS GO AND/OR STOREFRONT MANUFACTURER SHALL PROVIDE THE FOLLOWING ITEMS AS PART OF THE COMPLETE STOREFRONT SYSTEM ALUMINUM FRAMING AND FRAMING ACCESSORIES STEEL RFJNFORCEMENT ASTMI A 611 AND 570 (AS RECD) GLAZING AND GLAZING GASKETS FRAMING SYSTEM GASKETS, SEALANTS, AND JOINT FILLERS SEALANTS AND JOINT RLLEFtS FOR JOINTS AT PERIMETER BITUMENOUS PANT STOREFRONT COMPONENTS CENTER GLAZE SCREW SPLINE STOREFRONT FRAMING OR APPROVED EQUAL 4! STILE DOOR OR EQUAL MANUR DOOR TO BE 13/4' THICK GLAZED DOOR WITH MIN. 0,125 WA THICK EXTRUDED TUB" RAIL AND STILE MEMBERS (6063-T5 OR T6 ALLOY) BRACKETS AND RENFCRCEMENITS, COMPATIBLE WTH ADJACENT MATERIALS FASTENERS AND ACCESSORIES, C09POSCN-FESISTANT CONCEALED RASHINGA C09ROSCN RESSTANT WEATHER STRIPPINn MOLDED NEOPRENE COMPLYIW3 WITH ASTM D 2000 IMPACT - RESISTANT CONDITIONS SHALL BE ACHIEVED THROUGHOUT AS REQUIRED BY CODE SEE STRUCTRAL ENGINEERING FOR WIND LOAD PRESSURE REQUIREMENTS HARDWARE THRESHOLD EXTRUDED ALUMINUM ONE PIECE PER DOOR OPENINQ NON-SLP SURFACE PER MANUFACTURERS STANDARD LINE PULLS HANIDLE& STOREFRONT MANUFACTURERS STANDARD LINE PUSH BARR STOREFRONT MANUFACTURERS STANDARD LINE CLOSEFS: MANUFACTURER ST"ARD SIMILAR TO RIX901\0 WITH M19 INTERMEDIATE PIVOT (US26) TO COMPLY WITH CLOSING CYCLE FOR FBC 2002 AND ADA CYLINDERR MANUFACTURER STANDARD DOUBLE CYLINDER WITH DEADBOLT LOCK DEVICE CYLINDER GUARDS: PER MANUFACTURER STANDARDS WEATHER SWEEP MANUFACTUPOTS STANDARD EPDM BULB -TYPE NOTE ALL HARDWARE SHALL HAVE STANDARD BRUSHED NICKEL FINISH AND TO BE SELECTED BY ARCHITECT FINISHES FLUOROPOLYMER 2--COAT COATING SYSTEM PER MANUFACTURERS THERMOCAJRED SYSTEM COMPOSED OF INHIBITIVE PRIMER AND FLUCHOPMYMER COLOR TOPCOAT CONTAINING NOT LESS THAN 70 PERCENT POLYVINYUDENE FLUORIDE RESIN BY WEIGHT COMPLY WITH AAMA 6052 MANUFACTURERS STANDARD CCLOR LINE SELECTED BY ARCHITECT GLAZING STOREFRONT DOOR, TRANSOM, AND GLAZING BELOW 1T AFF SHALL BE FULLY TEMPERE11% WITH HORIZONTAL TEMPEP44G TO OONFORIVI WITH ANSI Z97.1 - IMPACT - RESISTANT GLAZING THROUGHOUT. SEE GLAZING SPECIFICATION SECTION INSTALLATION WHERE ALUMINUM WILL CONTACT DISSIMILAR METALS, PROTECT AGAINST GALVANIC ACTION BY PAINTING CONTACT SURFACES WITH PRIMER OR BY APR-YING SEALANTITAPE AS PECCMMENDED BY MANUFACTURER WHERE ALUMINUM WILL CONTACT COqCRETE OR MASONRY, PROTECT AGAINST CORROSION BY PANTING CONTACT SURFACES WITH BITUMENOUS PANT INSTALL COMPONENTS TO DRAIN WATER PASSI% JOINTS AND CONDENSATION OCCURING OR MIGRATING WTrHIN THE SYSTEM TO THE EXTERIOR M. GLAZING SYSTEM PERFORMANCE REQUIREMENTS PROVIDE GLAZING SYSTEMS THAT ARE PRODUCED, FABRCATED� AND INSTALLED TO WITHSTAND NORMAL THERMAL MOVEMENT, WIND LOADING, AND IMPACT LOADING, WITHOUT FAILURE INCLUD114G LOSS AND GLASS BREAKAGE ATTP43UTABLE TO THE FOLLOVONG DEFECT7VE MANUFACTURE, FABRICATION, AND NSTALLATION FAILURE OF SEALANTS OR GASKETS TO REMAIN WATERTIGHT AND AJRTIC44T DETERIORATION OF GLAZING MATERALS AND OTHER DEFECTS IN CONSTRUCTION GLASS THICKNESS INDICATED ON DRAWINGS ARE FOR DETAILING ONLY, CONFIRM GLASS THICKNESS BY ANALYZING PROJECT LOADS MINIMUM GLASS THICKNESS = 1/4 INCH OBTAIN GLASS FROM ONE SOURCE FOR EACH PRODUCT BELOW PRIMARY GLASS OF EACH (ASTIVI C 1036) TYPE HEAT -TREATED GLASS OF EACH (ASTM C 1048) CONDITION POLISHED WIRED GLASS (ASTIVIC 1048) PRODUCTS/MANUFACTURERS PRIMARY FLOAT GLASS: ASTM G 1036, TYPE I, TRANSPARENT GLASG� FLAT, QUALITY 03 CLASS 1 (CLEAF4 UNLESS OTHERWISE INDICATED CLASS 2 (SMOKE TINTED, HEAT-ABSORBW-i AND LIGHT PEDUCIW:3) MERE INDICATED. FULL HEIGHT V4� MIRROR UNLESS OTHERWISE NOTED HEAT -TREATED FLOAT GLASS ASTM C 1048, CONDITION A TYPE 1, CLASS 1 OR 2 (AS INDICATED), FLAT, QUALITY 03 FT CLASS 1 (CLEARI UNLESS OTHERWISE INDCATED FT CLASS 2 (SMOKE- TINTED, HEAT-ABSORBINCA AND LIGHT REDUCING) WHERE INDICATED. FULL HEIGHT 1/4� FULLY TEMPERED AS SPECIFIED ALL EXTERIOR GLAZI% SHALL BE IMPACT--FESISTANT, DOUBLE INSULATED� LIGHT GRAY TINT PER DRAWINGS N. PORTLAND CEMENT PLASTER PRODUCTS/MANUFACTURER EXPANDED METAL LATH DETFICH INDUSTRIES INC. UNITED STATES GYPSUM CO. DALE / INCOR INDUSTRIES INC UNIMAST INC METAL ACCESSORIES FRY REGLET CORPORATION UNITED STATES GYPSUM CO. DALE / INCOR INDUSTRIES NC UNIMAST INC PLASTIC ACCESSORIES ALABAMA METAL INDUSTRIES CORP. PLASTIC COMPONENTS INC VINYL CORP, STUCCO ACCESSORIES FLORIDA STUCCO CORP, HIGHLAND STUCCO UNITED STATES GYPSUM 00. RELATED MATERIALS EXPANDED METAL LATH TO COMPLY WITH ASTM C 847 STRUCTURAL QUALITY ZINC COATED CCMPL'rl% WITH ASTIVI A 653, G60 DIAMOND MESH TYPE PAPER BACKED LATH TO COMPLY WITH FS UU-13-790 TYPE I; VAPOR -PERMEABLE PAPER GRADE D, STYLE 2 CORNERBEADS, CASING BEADS, AND CONTROL JOINTS SHALL BE PVC PLASTIC TYPE, MR 0.035 INCH THICK PORTLAND CEMENT BASE COAT, ASTM C 150� TYPE I PORTLAND CEMENT FINISH COAT PER MANUFACTUIFERS STANDARD PACKAGED STUCCO, INCLUDING PORTLAND CEMENT, AGGREGATE, AND OTHER PROPRIETARY 84GREDENTS SAND AGGREGATE FOR BASE COATS* ASTIVI C 897 INSTALLATION TWO COAT WORK OVER CONCRETE UNIT MASONRY BASE -COAT' 1 PART PORTLAND CEMENT, 3/4 TO 11/2 PARTS LIMF, 3-4 PARTS AGGREGATE, 3/8' THICKNESS THREE COAT WORK OVER METAL LATR SCRATCH COAT 1 PART PORTLAND CEMENT, 0 TO 3/4 PARTS LIMF- 2 1/2 TO 4 PARTS AGGREGATE, 3/8" THICKNESS BROWN COAT I PART PORTLAND CEMENT, 0 TO 314 PARTS LIMF- 3-5 PARTS AGGREGATF, 1/4� THICKNESS FINISH COAT. PROPORTION MATERIALS FOR FINISH COATS IN PARTS BY VOLUME. USE 1 PART PORTLAND CEMENT, 34 TO 11/2 PARTS LIME 3 PARTS SAND, 1/8 INCH THICK Issue Date 09-03-21 00 LL ZZ LL :) E bgs 00 0 -j 00 M co A �� 3m 0 6 c: U) 0 C 0 0 LL m cli > 0 -c L- cu >% 0 CL -c N 4-a cu (D 0 -r tf 4- 2:% 0 () c: cl) (D < E m 0 a) -b-0 C 0 E Job Nwrber 2008 Revisilons A Sheet No. A6 WARRANTIES ARCHITECTURAL SPECIFICATIONS NOTE: NOT ALL ITEMS ARE APPUCABLE TO THIS PROJECT 0. GYPSUM BOARD SYSTEMS PFODL)CTS/MANUFACTUPEFIS DOMTAR GYPSUM COMPANY GEOPGA-PACIFC CORPORATION GOLD BOND BUILDING PRODUCTS UNITED STATES GYPSUM 00. GYPSUM BOARD MATERIALS STANDARD GYPSUM BOARD ASTM C36,5/8 INCH THICK ENDS SQUARE CJJT TAPERED EDGES FF WD GYPSUM BOARD ASTM C36 FIRE RESISTIVE- TYPE, UL RAW, 8 INCH THICK ENDS SQUARE �,Of, TAPERED EDGES MOISTURE RESISTANT GYPSUM BOARD ASTM C= 5/8 INCH THICK ENDS SQUARE CUT, TAPERED EDGES ACCESSORIES THERMAL INSULATION AS DEFINED CORNER BEADS, METAL EDGE TRIM, GA 201 AND GA 216- TYPE L, LK U EXPOSED REVEAL BEAD JOINT MATERIALS ASTM C475 RENFORCING TAPE, JOINT COMPOUND, ADHESIVE AND WATER P, METAL FRAMING AND FURRING SECTION INCWDES WALL, BULKHEAD� CEILING, AND FURRED SPACE FRAMING SYSTEM DESCRIPTION TO LIMIT FINISH SURFACE DEFLECTION TO 1/180 UNDER LATERAL PONT LOAD OF 100 LBS FABRICATE HORIZONTAL CELNG AND SOFFIT FRAMING TO LIW FINISH SURFACE TO 1/360 DEFLECTION UNDER SUPERIMPOSED DEAD LOADS AND WIND UPLIFT, FABRICATE VERTICAL WALL AND FURRED SPACE FRAMING PROIDUCTS/MANUFACTURERS MANUFACTURERS: PRODUCTS OF TYPES SPECIFIED IF ANY OF THE FOLLOWING LISTED FIRMS: DALE INDUSTRIES, INC. DIETRICH INDUSTRES� INC. GOLD BOND BUILDING PRODUCTS, USG NDUSTRIES. FRAMING MATERIALS INTEP40R WALLS: AS SPEaFED ON PLANS. FURRING., CHAMELa FORMED STEEL� MINIMUM 25 GAGE THICK 3/8 INCH DEEP X 3/4 INCH MAN CEILING CHANNELS- FORMED STEEL4 MINIMUM 18 GAGE THICK, 3/4 INCH DEEP X 1-1/2 INCH HIGH; LENGTH AS REQUIRED. HANGERS GALVANIZED STEEL, OF SIZE AND TYPE TO SUIT APPLICATION TO RIGIDLY SUPPORT CEILING COMPONENTS IN PLACE, TO DEFLECTION LIMITS AS INDICATED. LATERAL EFACINIG FORMED STEEL, MINIMUM 16 GALGE THICK S12E AND LENGTH AS REQUIRED. CASING BEAD. FORMED SHEET STEEL; MINIMUM 26 GAGE THICK DEPTH GOVERNED BY PLASTER THMESS; MAXJMUIVI POSSIBLE LENGTHR, EXPANDED METAL FLANGES� WITH SQUARE EDGES. CORNER BEAD FORMED SHEET STEEL, MINIMUM 26 GAGE THICK DEPTH GOVERNED BY RASTER THICKNESS, MAXAMUM POSSIBLE LENGTI-e, EXPANDED METAL FLANGES, WITH BULLNOSED EDGE. BASE SCREED FORMED SHEET STEEL, MINIMUM 26 GAGE THICK� DEPTH GOVERNED BY PLASTER THICKNESS, MAMMUM POSSIBLE LENGTHS; EXPANDED METAL FLAINGES, W7H BEVELLED EDGE ACCESSORIES FACTORY FABRICATED AND FINISH TRIM UNITS TYPES FOR FORMING PEVEALS� VEI'NITS OR OTHER INDICATED TRIM OR FEATURES SHALL BE OF TYPE AND DESIGN INDICATED, EXTRUDED ALUMINUM (6063-T5 ALLOY) AS MANUFACTURED BY FRY REGLET CO, MM SYSTEMS OR AS APPROVED BY ARCHITECT ANCHORAGE TIE WIFE, NALS, SCREWS AND OTHER METAL SUPPORTS, OF TYPE AND SIZE TO SUIT APPLICATION TO RGIDLY SECURE MATERIALS IN PLACE POLYETHYLENE SHEET. CLEAR 6 MIL THICK TE WIRE ANNEALED GALVANIZED STEEL FINISHES FRAMING MATERIALS: GALVANIZED. HANGERS, ANCHORS, AND FASTENING DEVICES. GALVANIZED. LATH MATERIALS: GALVANIZED. INSTALLATION VERIFY THAT SURFACES CONDITIONS ARE READY TO RECEIVE WORK. WALL AND FURRED SPACE FRAMING INSTALL LATHING AND FURRINIG FOR PORTLAND CEMENT PLASTER WORK IN ACC09DANCE WITH ASTM C1063 ERECT WALL FURI­*G BY DIRECTLY ATTACHING TO MASONRY WALLS. ERECT FURRINGG CHANNELS AT VERTICALLY, SECURE WITH FASTENERS ON ALTERNATE CHANNEL FLANGES AT MAMMUM 24 INCHES OC, SPACING3 FURRING CHANNELS MAXIMUM 24 INCHES ON CENTER NOT MORE THAN 4 INCHES FROM FLOOR AND CEILING LINES CEILING AND SOFFIT FRAMING INSTALL FJRRING TO HEIGHT INDICATED ERECT AFTER ABOVE CEILING OR SOFFIT WORK IS COMPLETE COORDINATE THE LOCATION OF HANGERS WITH OTHER WORK INSTALL FURFIINGi NDEPEMENT OF WALLS, COLUMNS, AND ABOVE CEILING WORK SECURELY ANCHOR HANGERS TO STRUCTURAL MEMBERS OR EMBED IN STRUCTURAL SLAB SPACE HANGERS TO ACHIEVE DEFLECTION LIMITS INDICATEIA SPACE MAIN CARRYING CHANNELS AT MAXIMUM 48 INCH CENTERS; NOT MORE THAN 2 INCHES FROM WALL SURFACES LAP SPLICE SECURELY. SECURELY FIX CARRYING CI-ANNEL-S TO HANGERS TO PREVENT TURNING OR TWISTING AND TO TRANSMIT FULL LOAD TO HANGERS. PLACE FURRING CHANNELS PERPENDICULAR TO CARRYING CHANNELS, NOT MORE THAN 2 INCHES FROM PERIMETER WALLS� AND RIGIDLY SECURE, LAP SPLICE SECURELY. RENFORCE OPENINGS IN SUSPENSION SYSTEM WHICH INTERRUPT MAIN CARRYING CHANNELS OR FURRING CHANNELS WITH LATERAL CHANNEL BRACING EXTEND BRAaNG3 MINIMUM 24 INCHES PAST EACH OPENING LATERALLY BRACE SUSPENSION SYSTEM. TOLERANCES MAXIMUM VARIATION FROM TRUE LINES AND LEVELS. V8 INCH IN 10 FEET. MAXIMUM VARIATION FROM TRUE POSITION: V8 INCH Q. SUSPENDED ACOUSTICAL CEILING CEILINGS. THE MANUFACTURER WARRANTS THAT THE C9LINGjS WILL REMAIN FREE FROM SAQ WARP, OR DELAMINATION AS A DIRECT RESULT OF DEFECTS IN THE MATERIALS OR FACTORY WORKMANSHIP, SUBJECT TO WARRANTY PROVISIONS OR INSTALLATION CONDITIONS AND EXCLUSIONS. WARRANTY PERIOD TEN YEARS FROM DATE OF INSTALLATION PRODUCTS ACOUSTICAL CEIUIG2 PANELS AND SUSPENSION SYSTEM ARMSTROING, USG OR APPROVED EQUAL ARMSTRONG- FIELD VERIFY AND MATCH EXISTING CONDITIONIS. SEE PLANS PANEL SIZE 24' x 24" (UON) PROVIDE TYPE 3, FORIVI Z PATTERN CE, CLASS A SUPPLEMENTAL MATERALS ANCHORINIG DEVICES: HOT DIPPED GALVANIZED STEEJ- ASTM A153 COATING CLASS C & D, SCREWS, BOLTS� HOOKS� AND EYES TE WIFE 16 GAGE MIN. (ASTM A 641), ZINC -CARBON STEEL TOUCH UP PANT TYPE AND COLOR TO MATCH AOC)USTICAL AND GRID UNITS CONCEALED ACOUSTICAL SEALANT: NON--DRYINIG� NON -SHRINKING -BLEEDING- A NON -�, GUNNABLE SEALANT PECORA BA-98 OR TREMCO ACOUSTICAL SEALANT COORDINATION COORDINATE LAYOUT AND INSTALLATION OF ACOUSTICAL PANELS AM SUSPENSION SYSTEM COMPONENTS WITH OTHER CONSTRUCTION THAT PENETRATES CEILINGS OR IS SUPPORTED BY THEM, INCLUDING LIGHT FIXTURES, HVAC EQUIPMENT, FIRE SUPPRESSION SYSTEM AND PARTITION ASSEMBLIES EXTRA MATERALS FURNISH EXTRA MATERIALS THAT MATCH INSTALLED PRODUCT AND ENSURE QUANTITY OF FULL-SIZE UNITS EQUAL TO 5 PERCENT OF AMOUNT INSTALLED R, RESILIENT FLOORING PRODLCTS/MANUFACTURER VINYL COMPOSITION TILE ARMSTRONG STANDARD E)(CELON - IMPERIAL TEXTURE COLOR TO MATCHExisTINGCONDITIONS (FELD VEF". VCT SdALL CONFORM TO THE REQUIREMENTS OF ASTM F1066 a -ASS 2 - THROUGH PATTERN, WALL BASE PROVIDE 4! HIGH ARMSTRONG CCLOR INTEGPATED WALL BASE WITH A MATTE FINISH. FELD VERIFY AND MATCH EXISTING CONDITIONS. ADHESIVES, ACCESSORIES AND INSTALLATION PER MANUFACTURERS RECOMMENDATIONS. LUXURY VINYL TILE (LVT) WITH WOOD PLANK ARMSTRONG NATURAL CREATIONS - ARBOPART 1/8" THICKNESS CONFIRM COLOR WITH OWNER PRIOR TO ORDERM FLOORING SI-ALL CONFORIM TO THE REQUIREMENTS OF ASTM F1700 - CLASS 3, TYPE B - EMBOSSED SURFACE WALL BASE PROVIDE 4� HIGH ARMSTRONG COLOR NTEGRATED WALL BASE NTH A MATTE FINISH. ADHESIVES, ACCESSORIES AND INSTALLATION PER MANUFACTURERS RECOMMENDATIONS. (UNLESS NOTED OTHERWISE) OR EQUAL TO BE APPROVED BY ARCHITECT OR OWNER QUALITY ASSURANCE OBTAIN EACH TYPE, COLOR AND PATTERN OF TILE FROM A SINGLE SOURCE WITH RESOURCES TO PROVIDE PRODUCTS OF CONSISTENT QUALITY IN APPEARANCE AND PHYSICAL PROPERTIES WITHOUT DELAYING PROGRESS IN WC)RK PROVIDE RESILIENT FLOOR TILE WITH PERFORMANCE CHARACTERST)CS AS TESTED PER ASTIVI E648 CRITICAL RADIANT FLUX AND ASTM E 662 SMOKE DENS" OR UL TESTING EXTRA MATERIALS FURNISH NOT LESS THAN ONE BOX FOR EACH 50 BOXES OR FRACTION TI-ERE OF S. CERAMIC TILE FLOORING PRODUCTS/MANUFACTUIPER AMERICAN OLEAN TILE CO. DAL -TILE CORP. CROSSVILLE FLORIDATII F CUSTOM BUILDING PRODUCTS LATICRETE INTERNATIONAL, INC L & M SURCO MFG, INC, QUALITY ASSURANCE SOURCE LIMITATIONS FOR TILE, OBTAIN COLOR GRADE, FINISH, TYPE, COMPOSITION, AND VARIETY OF TILE FROM ONE SOURCE WITH RESOURCES TO PROVIDE PRODUCTS FROM THE SAME PRODUCTION RUN FOR EACH CONTIGLK)US AREA OF CONSISTENT QUALITY IN APPEARANCE AND PHYSICAL PROPERTIES WITHOUT DELAY IN WlORK. SOURCE LIMITATIONS FOR SETTING AND GROUTING MATERIALS: OBTAIN INGREDIENTS OF A UNIFORM QUALITY FOR EACH MORTAR ADHESIVE, AND GROUT COMPONENT FROM A SINGLE MANUFACTURER AND EACH AGGREGATE FROM ONE SOURCE OR PRODUCER EXTRA MATERIALS FURNISH EXTRA MATERIALS DESCRIBED BELOW THAT MATCH PRODUIC-TS INSTALLED, APE PACKAGED WITH PROTECTIVE COVERING FOR STORAGE, AND ARE IDENTIFIED WITH LABLES DESCRIBING CONTENTS. INSTALLATION COMPLY WITH PARTS OF ANSI A108 SERIES OF TILE INSTALLATION STANDARDS IN *SPECIFICATIONS FOR INSTALLATION OF CERAMIC TILE" THAT APPLY TO TYPES OF SETTING AND GROUTING MATERIALS AND THE METHODS USED COMPLY NTH 'HANDBOCK FOR CERAMIC TILE NSTALLATKW EXT� TILE WORK INTO RECESSES AND UNDER 08 BEHIND EQUPMENT AND FIXTURES TO FORM A COMPLETE COVERING WITHOUT INTERRUPTIONS. TERMINATE WORK NEATLY AT OBSTRUCTIONS, EDGES, AND CORNERS WITHOUT DISRUPTING PATTERN OR JOINT ALIGNMENTS. LAY TILE IN GRID PATTERN, UNLESS OTHERWISE INDICATED. ALIGN JOINTS WHEN ADJOINING TILES ON FLOOR BASF, WALLS, AND TRIM ARE THE SAME SIZE LAYOUT TILE WORK AND CENTER TILE FIELDS IN BOTH DIRECTIONS IN EACH SPACE OR ON EACH WALL AREA ADJUST TO MINIMIZE TILE CUTTING, PROVIDE UNIFORM JOINT WIDTHS, UNLESS OTHERWISE INDICATED T. GLUE DOWN CARPETING (IF APPLICABLE PRODUCTS/MANUFACTURER ATLAS CARPET MILLS, INC. SHAW CARPETING QUALITY ASSURANCE THE CONTRACTOR SHALL PROVIDE TO THE OWNER WRI17EN WARRANTIES FROM THE MANUFACTURER FOR EDGE RAVELING, 1096 LOSS OF FACE FIBER SNAGS, RUNS, AND DELAMINATION TEN YEARS, DELAMINATION: TEN YEARS, WEAR TEN YEARS EXTRA MATERIALS FURNISH EXTRA MATERIALS THAT MATCH PRODUCTS INSTALLED AND THAT ARE PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING CONTENTS CARPET TO BE FULL -WIDTH EQUAL TO 5 PERCENT OF AMOUNT INSTALLED FOR EACH TYPE INDICATED, BUT NOT LESS THAN 10 SO. YIDS. PRODUCTS PROVIDE MANUFACTURERS STANDARD LINE COLOR AND PATTERN OPTIONS, CARPET BACKING, CUSHION OR PADDING, AND INSTALLATION ACCESSORIES INCLUDING� BUT NOT LIMITED TO, ADHESIVES, LEVELING COMPOUNDS, TACKLESS CARPET STRIPPING, SEAMING CEMENT, AND METAL EDGE STRIPS PERFORMANCE CHARACTERISTICS AS FOLLOWS: CRITICAL RADIANT FLUX CLASSIFICATION: NOT LESS THAN 22W/SQ. CM DRY BREAKING STRENGTH: NOT LESS THAN 100 LBF PER ASTM D 2646 RESISTANCE TO INSECTS� COMPLY WITH AATCC-24 NOISE REDUCTION COEFICENT. PER ASTIM C 423 COLORFASTNESS TO CROCKING NOT LESS THAN 4, WET AND DRY PER AATCC-165 COLORFASTNESS TO LIGHT: NOT I ESS THAN 4 AFTER 40 AFU PER AATCC-16 ANTIMICROBIAL ACTIVITY: NOT LESS THAN 2-MM HALO OF INHIBITION FOR GRAM -POSITIVE BACTERIA NOT LESS THAN 1 MM HALO OF INHIBITION FOR GRAM --NEGATIVE BACTERIA NO FUNGAL GROWTH PER AATOC-174 INSTALLATION DIRECT GLUE DOWN INSTALLATION TO COMPLY WITH CRI 104� SECTION 8, ODIRECT GLUE --DOWN INSTALLATION" INSTAL ER SHALL BE EXPERIENCED WHO IS CERTIFIED BY THE FLOOR COVERING INSTALLATION BOARD OR WHO CAN DEMONSTRATE COMPLIANCE WITH ITS CERIRCATION PROGRAM REQUIREMENTS. PROVIDE PRODUCTS WITH THE CRITICAL RADIANT FLUX CLASSIFICATION AND AS DETERMINED BY TESTING IDENTICAL PRODUCTS PER ASTM E 648 BY AN INDEPENDENT TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION U. FINISH CARPENTRY PRODUCTS LUMBER MATERIALR SHEET MATEPIALSN SOFTWOOD PLYWOOD PS 1 GRADE C-D GRADED IN ACZMANCE WITH AW CUSTOM VENEER CORE, FIR FACE SPECIES, FLAT CUT USE FOR FIXED SHELVING OR SHELVING ON ADJUSTABLE STANDARDS LUMBER FOR SHIMMING AND BLOCKING SOFTWOOD LLA4BER OF SOUTHERN FINE SPECIES FABRICATION FABRACATE MILLWORK TO AW STANDARDS SHOP ASSEMBLE WCIRK FOR DELIVERY TO STE, PERIMITTINGG PASSAGE THROUGH BUILDNG OPENINGS FIT EXPOSED SHEET MATERIAL EDGES WITH PLASTIC EDGING CAP EXPOSED PLASTIC LAMINATE FINISH EDGES WITH MATERIAL OF FINISH AND PATTERN WHEN NECESSARY TO CUT AND FIT ON STE, PROVIDE MATERIALS WITH AMPLE ALLOWANCE FOR Ck)TTING. PROVIDE TRIM FOR SCRIBING AND SITE CUTTING APPLY PLASTIC LAMINATE FINISH IN FULL UNINTERUPTED SHEETS CONSISTENT WITH MANUFACtOlEb SIZES FIT CORNERS AND JOINTS HAIRLINE: SECURE WITH CONCEALED FASTENERS APPLY LAMINATE BACKING SHEET TO REVERSE 61DE OF PLASTIC LAMINATE FINISHED SURFACES V. PAINTING PRODUCTS/IVIANUFACTUREPS MOORE BENJAMIN MOORE & CO. CA CA PORTER PORTER PAWS SW SHERWIN WILLIAMS SCHEDULE CEMENTITIOUS MATERIALS ELASTOMERIC FNISR THREE COATS, MIN. 35 MILS DRY FILM PF#ilER BLOCK FILLERISEALER FIRST/SECOND COAT& ELASTOMERIC TYPE GYPSUM DRYWALL SYSTEMS SEMI--GI-OSS ENAMEL FINISH: TWO COATS� MIN. 3.5 MILS DRY FILM PRIMER VINYL PRIMER FINISH COAT LATEX SEMI--GLOSS� ENAMEL MOISTURE RESISTANT GYP BOARD ASSEMBLIES EPDXY FINISH: TWO COATS AS RECOMMENDED BY MANUFACTURER PRIMER EPDXY PRIMER FINISH COAT EPDXY ENAMEL WOODWORK (OPAQUE FINISH) SEMI -GLOSS ENAMEL THREE COATS UNDERCOAT. UNDERCOATER FIRST AND SECOND COATS LOW LUSTRE ALKYD ENAMEI WOODWORK OPANSPAPENT RN64 STAINED -VARNISH RUBBED FNISH: THREE COATS OVER STAIN PLUS FILLER ON OPEN -GRAIN WOOD WIPE FILLER BEFORE VARNISH COAT STAN COAT OIL TYPE INTERIOR WOOD STAN INTERlIOR OIL STAN FIRST COAT SEALER FILLER COAT PASTE WOOD FILLER SECOND AND THIRD COATS� OIL RUBBING3 VARNISH, SATIN VARNISH FERROUS METAL SEMP-GLOSS ENAMEL FINISH: TWO COATS OVER PRIMER PRIMER SYNTHETIC, QUICK-DRYM RUST INHIBITING ROL ANTI CORROSIVE METAL PRIMER UNDERCOAT: INTERIOR ENAMEL UNDERCOAT, LOW LUSTRE ALKYD ENAMEL FINISH COAT INTERCR SEMI-aOSS, ODORLESS� ALKYD ENAMEL, LOW LUSTRE ALKYD ENAMEL ZIW--COATED METAL SEMI -GLOSS FINISH: TWO COATS OVER PRIMER PRIMER GALVANIZED METAL PRIMER UNDERCOAT INTERIOR ENAMEL UNDERCOAT, LOW WSTRE ALKYD ENAMEI FINISH COAT: INTERIOR SEMI -GLOSS, ODORLESS, ALKYD ENAMEL, LOW WSTRE ALKYD ENAMEL W. FIRE EXTINGUISHERS. CABINETS, AND ACCESSORIES PRODUIC-TS/MANUFACTURERS JL. INDUSTRIES LARSENS MANUFACTURING CO. MODERN METAL PRODUCTS BY MUCKLE POTTER-ROEMER INC. SAMSON METAL PRODUCTS INC QUAILITY ASSURANCE OBTAIN EXTINGUISHERS AND CABINETS FROM SINGLE SOURCE MANUFACTURER AND SUPPUER FIRE EXTINGUISHERS SHALL BE UL LISTED WITH UL LISTING MARK FOR TYPE, RATING, AM CLASSIFICATION OF EXTIINGUISHER FIRE BM-4GUISHERS PROVIDE FIRE DMNIGUISHERS FOR EACH LOCATION INDICATED STANDARD 'REU COLOR AND FACTORY ENAMEL FINISH USEmuL-nPURP0SE DRY CHEMICAL TYPE UL-RATED 2-A l0f3lC 5 LB. NOMINAL CAPACTY, IN ENAMEI En STEEL CONTAINER STRUCTURAL SPECIFICATIONS CAST IN PLACE 1 ALL CONCRETE FORMWORK TO BE PERFORMED IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE PUBLICATION 347. 2 THE STANDARDS OF THE ACI BUILDING3 CODE 318 AND MANUAL OF PRACTICE ACI PUBLICATION 315 SHALL BE FOLLOWED FOR ALL DETAJLINIG� FABRICCATION, AND PLACEMENT OF ALL REINFORCANG3 STEEL AND ACCESSORIES. WORK SHALL ALSO BE PERFORIVIED IN ACCORDANCE WITH CPS MANUAL OF PRACTICE, AND SECTIONS 63 AND 65� FOR PLACING REINFORCING BARS, DO NOT USE CUT MASONRY OR W= FOR BAR SUPPORTS. 3 PROVIDE DEFORMED BILLET STEEL REINFORCING BARS, PLAN FINISH, OF THE SIZES INDICATED ON THE DRAWINGS, OF 60 KSI YELD GRADE, PER ASTIVI A615 MI"MUM166 GAUGE TIE WIFE 4 PROVIDE .006 INCH (6 MIL) THICK CLEAR POLYETHYLENE VAPOR BARRIER FILM AS SHOWN ON DRAWINGS LAP ALL SEAMS AND TAPE TIGHT, TAPE REPAIR ANY PUNCTURES. 5 PROVIDE WELDED WIFE FABRIC CONFORMING TO ASTM A185 IN SIZES INDICATED ON DRAWINGS 6 ALL CAST---IN-PLACE CONICRETE SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 3000 POUNDS PER WJARE INCH AT 28 DAYS. CEMENT SHALL BE ASTM C150, TYPE I NORMAL PORTLAND, GREY COLOR USE ONE BRAND THROUGHOUT FINE AND COURSE AGGREGATES SIALL BE PER ASTM AND ANY AIR ENTPANMENT PER ASTM C260. 7 UNLESS OTHERWISE NOTED ALL SLAM SHALL HAVE SMOOTH TROWEL FINISHED TOP SURFACES WITH SURFACE FURTHER PREPARED FOR ANY FINISH MATERIAL AS REQUIRED. ALL SLABS, WHETHER HORIZONTAL OR SLOPED, SHALL BE LEVEL WITHIN ITS DES04ED PLANE WITH A MAXJMUM VARIANCE OF 1/4� IN TEN FEET IN ANY DFECTION. 8 PROVIDE PROPERLY TIED SPACERS� CHARS, BOLSTERS, ETC, AS REQUIRED AND NECESSARY TO ASSEMBLE, PLACE AND SUPPORT ALL REINFORCING IN PLACE USE WIFE BAR TYPE SUPPORTS COMPLYING WITH CRSI RECOMIVENDATIONS. USE PLASTIC TIP LEGS ON ALL EXPOSED SURFACE& 9 ALL BEAM, SPANDRELS AND SLABS SHALL BE POURED MONIOLITHICALLY, EXCEPT FOR REQUIRED CONSTRUCTION JOINTS. PROPOSED CONSTRUCTION JOINT LOCATIONS SiALL BE SUBMITTED TO ENGINEER FOR APPROVAL 10. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS, SLEEVES, AND SLAB RECESSES AS REQUIRED BY OTHER TRADES BEFORE C04CFETE IS PLACED NO SLEEVE, OPENING, OR INSERT MAY BE PLACED IN BEAMS, JOISTS, OR CO-UMNS UNLESS APPROVED BY THE ENGINEER ft CONTRACTOR SHALL VERIFY EMBEDDED ITEMS, INCLUDING BUT NOT LIMITED TO ANCHOR BOLTS BOLT CLUSTERS WaD PLATES ETC, BEFORE PLACING CONCRETE NOTIFY ENGINEER OF ANY CONFLICTS WITH REBAR 12, SEE ARCHITECTURAL DRAWINGS FOR REQUIRED CONCFETE FINISHES. 13 ALL CONCRETE SAALL BE CURED IMMEDIATELY AFTER FINSHING OPERATIONS IN ACC09DANCE WITH ONE OF THE FOLLOWING METHODS. A) APPLY A 3096 SOLIDS LKM MEMBRANE FOPMING CHEIVOCAL CUP44G COMPOUND IN ACCORDANCE WITH ASTM C-309, B) PROVIDE CONTINUOUS MOISTURE TO CONCRETE IN ACCORDANCE WITH ACI 301. 14. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROPER DESIGN AND CONSTRUCTION OF ALL FORMWORK SHORING� AND RESHICIRING. 15. RESTRICT THE ADDITION OF MIX WATER AT THE JOB SITE. DO NOT ADD WATER WITHOUT THE APPROVAL OF THE GENERAL CONTRACTOR AND DO NOT EXCEED SLUMP LIMITATIONS OR TOTAL ALLOWABLE WATER TO CEMENT RATIO USE COLD WATER FROM THE TRUCK TANK AND FEW TO ACHIEVE CONSISTENCY THE REPORTS SAALL INDICATE HOW MUCH WATER WAS ADDED AT THE JOB SITE 16. MAXIMUM WATER TO CEMENT RATIO, A) 4000 PSI, 28-DAY COMPRESSIVE STRENGTH, W/C RATIO, 0.44 MAXJMUM (NON-AIR--ENTRANO), 036 MAXIMUM (AIR-ENTRAINEID), B) 3000 PSI, 28-DAY COMPRESSIVE STRENGTH, W/C RATION, 0.58 MAXIMUM (NON-AIR---ENTRANED), 0.47 MAAMUM (AIR -ENTRAINED). 17, REINFORCING BAR COVER A) FOOTINGS T B) COLUMNS �-IIZ C) BEAM �-VZ D) SLABS 3/4' (INTEI" 1-1/2' (EXTERIOR) la REPAIR AND PATCH DEFECTIVE AREAS WITH CEMENT MORTAR IMMEDIATELY AFTER REMOVAL OF FORMS, EXCEPT WHERE REIWORCNG IS VISIBLE C0'%ffACT STRUCTURAL EWAE69 FOR EVALUATION OF EXPOSED REINFORCING 19 PROVIDE CORNER BARS AT ALL BEAM AND WALL FOOTING CORNERS TO MATCH HORIZONTAL BARS. 20. ALL BUILDING AND SITE SI-Affi--ON-GRADE S:HALL BE AT LEAST 4� THICK REINFORCED WITH 6X6-W1.4 X W14 W.W.F, ON 6 MIL VAPOR BARRIER WITH SAW -CUT CONTROL JOINTS 20'-0' OC EACH WAY INCLUDING HOUSEKEEPING PADS AS REQUIRED SEE PLANS FOR OTHER CONDITIONS. 21. STEP AND SLOPE ALL WALKWAYS AWAY FROM THE BUILDING FIBERIMESH CONCRETE REINFORCING 1. RBB:WESH IS USED AT THE RATE OF 1 BAG OF 15 POUNDS (680 GRAMS) PER CUBIC YARD OF CONCRETE, OR 1 BAG OF 9 KILO PER CAJBC METER 2 FOR TRANSIT MIXED CONCRETE, EMPTY CONTENTS OF ONE BAG FOR EACH CUBIC YARD OF CONCRETE INTO THE MIXEIR ANYTIME AFTER THE INITIAL MIXING WATER HAS BEEN RIBBONED WITH THE CEMENT AND AGGREGATES ALLOW MINIMUM 3-4 MINUTES BEYOND NORMAL MIXING TIME FOR PROPEIR DISTRIBUTIOR a RBEFtMESH MAY BE ADDED TO THOROUGHLY MIXED CONCRETE AT THE JOBSITE WITH APPROXIMATELY 4--5 MINUTES ADDITIONAL MIXING TIME NOTE MIXING TIME IS LESS IF FIBERS ARE INTRODUCED SLOWLY TO CONCRETE THAT HAS BEEN MIXED 4 FOR CENTRAL MIXED CONCRETE, FIBERMESH MAY BE ADDED DURING-3 OR AFTER BATCHINGG SEQUENCE� OR AFTER CONCRETE HAS BEEN THOROUGHLY MIXED. 5. DUE TO VARIATIONS IN MIXER PERFORMANCE SOME ADDITIONAL MIXING MAY BE REQUIRED. PROLONGED MIXING DOES NOT ADVERSELY AFFECT DISTRIBUTION OF FIBERS. 6 FIBERMESH SHOULD NOT BE ADDED TO THE MIXER FIRST. COLD -FORM STEEL FRAM 1. ALL STEEL FRAMING SHALL CONFORM TO "THE SPECAFICATION FOR THE DESIGN OF COLD --FORMED STEEL STRUCTURAL MEMBERS!, LATEST EDTION, BY THE AISI. 2 WELDED CONNECTIONS SHALL CONFORM TO "CODE FOR WELDING IN BUILDING CONSTRUCTOR Dl.0 BY THE AWS. 3 ASTM A-568 STANDARD SPEaFCATICN FOR GENERAL REQUIFEMENTS FOR STEEL, CARBON AND HIGH STPENGTH LOW -ALLOY HOT POLLED SHEET AND COLD ROLLED SHEET, 4. ALL STEEL FRAMING SHALL BE INSTALLED BY PERSONNEL EXPERIENCEID IN LIGHT GAUGE STEEL FRAMING INSTALLATION. 5 WHERE STEEL FRAMING MB03ERS APE COMPONENTS OF ASSEMBLIES INDICATED FOR A FIRE-RESSTANCE RATING INCLUDING THOSE REQUIRED FOR COMPLIANCE NTH GOVERNING REGULATIONS, PROVIDE MEMBERS WHICH HAVE BEEN APPROVED BY GOVERNING AUTHORITIES HAVING JURISDICTION. 6. PROTECT LIGHT GAUGE STEEL FRAMING MEMBERS FROM RUSTNG AND DAMAGE DELIVER TO PROJECT SITE IN BUNDLES, FULLY IDENTIFIED WITH NAME� BRAND, TYPE AND GRADE STORE OFF GROUND IN A DRY VENTILATED SPACE OR PROTECT WITH SUITABLE WATERPROOF COVERINGS. 7 WITH EACH TYPE OF STEEL FRAMING PEOUIRED� PROVIDE MANUFACTURER'S STANDAFID STEEL RUNNERS (TRACKS), BLOCKING, LINTELS, CUP AW-4-ES, BRACING, REINFORCEMENTS, FASTENERS AND ACCESSORIES AS RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED AS NEEDED TO PROVIDE A COMPLETE STEEL FRAMING SYSTEM. 8. FABRICATE METAL FRAMING COMPONENTS OF STRUCTURAL QUALITY SHEE7 STEEL NTH A MINIMUM YIELD PONT OF 40,000 PSI FOR STUOS� AND 33,000 PSI FOR RUNNERS, ASTM A446. 9 SCREWS SHALL BE AS RECOMMENDED BY MANUFACTURER 10. PROVIDE GALVANIZED FINISH TO METAL FRAMING COMPONENTS COMPLYNG WITH ASTIVI A525 WITH A G60 COATING. 11. PROVIDE MANUFACTURER'S STANDARD STRUCTIJRAL V SHAPED STEEL STUDS OF SIZE, SHAPE AND GAILGE NDICATED� WITH A NOMINAL 1-3/4" FLANGE AND MINIMUM 11Z FLANGE RETURN LIP BY UNIMAST, INC, OR PRIOR APPROVED EQUAL MINIMUM STRUCTURAL PROPERTIES: I = 22675 NA s = .7328iKa 12. FRAMING COMPONENTS MAY BE PREFABRICATED INTO PANELS PF40R TO ERECTOR FABRICATE PANELS PLUMB, SOUARE- TRUE TO LINE AND BRACED AGAINST RACKING WITH JOINTS WELDED. PERFORM LIFTING OF PREFABRICATED PANELS IN A MANNER TO PREVENT DAMAGE OR DISTORTION. 13 INSTALL METAL FRAMING SYSTEMS IN ACCORDANCE WITH MANUFACTURERS PRINTED OR WRITTEN INSTRUCTIONS AND RECOMMENDATIONS� UNLESS OTHERWISE INDICATED. 14, INSTALL CONTINUOUS TRACKS SIZED TO MATCH STUD DEPTH. ALC44 TRACKS ACCURATELY TO LAYOUT AT BASE AND TOPS OF STUDS SECURE TRACKS AS RECOMMENDED BY STUD MANUFACTURER FOR TYPE OF CONSTRLr-TION INVOLVED� EXCEPT DO NOT EXCEED 24� OC SPAaNG FOR NAIL OR POWDER-DRIVENI FASTENERS OR 16' OC, FOR OTFER TYPES OF ATTACHMENT. PROVIDE FASTENERS AT CORNERS AND ENDS OF TRACKS. 15. WHERE REQUIRED, TEMPORARY BRACING SHALL BE PROVIDED UNTIL ERECTION IS COMPLETED. 16. RESISTANCE TO BENDING AND ROTATION ABOUT THE MINOR AXIS SHALL BE PROVIDED BY MECHANICAL LATERAL BRAOINGS WHERE REQUIRED 17, ATTACHMENTS OF SIMILAR COMPONENTS SHALL BE DONE BY WELDING SCREW ATTACHMENT, OR BOLTING WIRE TYING OF FRAMING COMPONENTS SHALL NOT BE PERMITTED. la WELDING OF MEMBERS LIGHTER THAN 18 GAUGE SHALL NOT BE PERMITTED. 19 SPLICES SHALL NOT BE PERMITTED 2o. MINIMUM NUMBER OF EQUALLY SPACED HORIZONTAL WALL BRIDGNG FOR THE HEIGHTS SHOWN: UP TO 10, - 1 ROW 1U TO W - 2 ROWS ABOVE W - AT 4! CENTERS 21. FULLY INSTALL ALL BRIDGING BEFORE APPLYING LOADS 22. FOR WELDED CONNECTIONS, FUSION WELDING IS RECOMMENDED WITH A DIRECT CURRENT WELDER OF 200 OR MORE AMPERE CAPACITY� USE A HEAT OF 60 TO 90 AMPERES (DEPENDING ON THE GAUGE OF METAL) I ALONG WITH ASTM E60 R ECTRODES. 23 SUBMffTED SHOP DRAWINGS MUST BE CHECKED AND SIGNED BY THE GENERAL CONTRACTOR EXISTING STEEL 1. VERIFY THE EXACT LOCATION AND WEGHT OF ALL MECHANICAL EQUIPMENT WITH THE MECHANICAL CONTRACTOR PP40R TO FABRICATION OF SUPPORTS ATTACHED TO EXIST STEEL JOISTS. 2- ALL HANGERS TO SUPPORT MECHANICAL ECIUIPMIENT TO BE SUPPORTED BY THE TOP OR BOTTOM CHORD OF JOISTS AND SHALL BE LOCATED AT THE PANEL POINT OF THE JOIST IF HANGERS MUST BE LOCATED IN BETWEEN PANEL POINTS, PROME JOIST STIFFENER AS INDICATED IN DETAILS. ALL HANGERS TO BE LOCATED AT THE CENTERLINE OF THE BOTTOM CHORE) MEMBER a PROVIDE BOTTOM CHORD CEILING ExTENGKM wHe:E REQUIRED BY ARCHITECT. 4 DO NOT HANG OR ATTACH DUCTWORK CONDUIT MING EQUIPMENT, CElUNGa ETC FROM METAL DECKING SPECIFICATIONS GENERAL NOTE: THE SPECIFICATIONS INDICATED ON THIS PAGE ARE ARCHITEC7S RECOMMENDATIONS ONLY. NOT ALL ITEMS ARE APPLICABLE TO THIS PROJECT. GENERAL CONTRACTOR TO VERIFY OWNER'S PREFERENCES PRIOR TO ORDERING MATERIALS OR PERFORMING WORK Issue Date 09-03-21 c 0 co in M 0 LL (D Z, wo. LL 0 5 E c 090 0 4) 00 0 - N co 0 M�w S 0 cu 0 C 0 [Z cu cli > 0 c: cu > a) CL a) N a) M a) 0 -r lf 4- 0 0 -f-j 70 cl) V- a) < E cu 0 a) a) 0 (D E a) Job Number 2008 Revisions A A" A" Sheet No. A7 I I T I T- -i I I -T ------- 7FTF-M -fl-91W F !.j 1 1& !iViT101 I --,F w 1.--, 1 i I Ij 1 T- -I - ------- F-- i MECHANICAL SPECIFICATIONS SCOPE: THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE THE DRAWINGS AND SPECIFICATIONS BEFORE SUBMITTING A PROPOSAL. ALL WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODES SEVENTH EDITION (2020), WITH ALL AMENDMENTS, AND LOCAL CODES AND ORDINANCES. INSTALLATION SHALL COMPLY WITH THE CODE REFERENCED STANDARDS SET BY NFPA, ASHRAE, ASPE, SMACNA, NEC AND UL. THE SYSTEMS, EQUIPMENT, DEVICES AND ACCESSORIES SHALL BE INSTALLED, FINISHED, TESTED AND ADJUSTED FOR CONTINUOUS AND PROPER OPERATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK FITTING IN PLACE AND SHALL COORDINATE WITH OTHER TRADES TO AVOID INTERFERENCE WITH THEIR WORK. THE INFORMATION GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED, BUT ITS EXTREME ACCURACY IS NOT GUARANTEED. THE DRAWINGS ARE DIAGRAMMATIC, INTENDED TO SHOW GENERAL ARRANGEMENT, CAPACITY AND LOCATION OF VARIOUS COMPONENTS, EQUIPMENTS, AND DEVICES. IF WORK IS REQUIRED IN A MANNER TO MAKE IT IMPOSSIBLE TO PRODUCE FIRST CLASS WORK, OR SHOULD DISCREPANCIES APPEAR AMONG THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND THE MANUFACTURER'S RECOMMENDATIONS,THE CONTRACTOR SHALL REQUEST INTERPRETATION BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION WHETHER OR NOT SPECIFIED IN THE DOCUMENTS. REQUIRED COORDINATION: ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS AND PIPING (INCLUDING DIVIDED DUCTS) AND TRANSITIONS AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. CONSTRUCTION PLANS: IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. REQUIRED ACCESS: CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT AND DEVICES THAT REQUIRE REPLACEMENT, SERVICING, ADJUSTING OR MAINTENANCE SHALL BE LOCATED TO ALLOW EASY ACCESS AND SPACE FOR REMOVAL OF INTERNAL ASSEMBLIES, IF REQUIRED. CONTRACTOR SHALL PROVIDE ACCESS PANELS WHERE REQUIRED TO ALLOW ACCESS, EVEN IF NOT INDICATED ON THE DRAWINGS AT NO ADDITIONAL COST TO OWNER. WIND RESISTANCE: ALL EQUIPMENT, APPLIANCE AND SUPPORTS LOCATED EXTERIOR OF THE FACILITY SHALL BE INSTALLED TO RESIST WIND LOADS AS DETAILED IN THE BUILDING CODE. CUTTING AND PATCHING: ALL OPENINGS AROUND DUCT OR PIPE PENETRATIONS THROUGH SMOKE OR FIRE RATED FLOORS, CEILINGS OR WALLS SHALL BE SEALED AIRTIGHT WITH MATERIALS HAVING A RATING EQUAL TO THE MATERIAL OF THE WALL, CEILING OR FLOOR PENETRATED. EQUIPMENT TAGS: ALL EQUIPMENT WILL HAVE A PERMANENTLY FIXED ENGRAVED PHENOLIC LABEL CORRESPONDING TO THE EQUIPMENT TAG ON THE ENGINEER'S DRAWINGS. FIRESTOPPING: UL APPROVED MATERIALS AND METHODS SHALL PROTECT THE PENETRATIONS OF FIRE AND/OR SMOKE RATED WALLS, CEILINGS OR FLOORS. THE RATING OF THE FIRESTOPPING SHALL EQUAL THE RATING OF THE RATED ASSEMBLY. ALL INSULATION SHALL HAVE COMPOSITE FIRE AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE ASTM E-84, NFPA-225, UL-723 NOT EXCEEDING: FLAME SPREAD 25 SMOKE DEVELOPED 50 FUEL DISTRIBUTED 50 ACCESSORIES SUCH AS ADHESIVE, MASTIC, CEMENTS AND TAPES SHALL HAVE THE SAME COMPONENT RATING AS LISTED ABOVE. START-UP: CONTRACTOR SHALL STARTUP ALL EQUIPMENT AND FOLLOW THE MANUFACTURER'S START-UP PROCEDURES. OPERATING AND MAINTENANCE DATA: SUBMIT THREE COPIES OF MANUFACTURER'S OPERATING AND MAINTENANCE INSTRUCTIONS AND SPARE PARTS LIST FOR EACH PIECE OF EQUIPMENT. CONDENSATE DRAIN PIPING: CONDENSATE DRAIN PIPING SHALL BE PVC TYPE DWV. DRAINS SHALL BE PITCHED NOT LESS THAN 1 PERCENT. RUNS SHALL BE AS SHORT AS POSSIBLE WITHOUT ANY DIPS TO TRAP WATER AND INTERFERE WITH PROPER DRAINAGE. PROVIDE TRAPS AND CLEANOUTS AT DRAIN PAN CONNECTIONS. RUN CONDENSATE DRAIN PER PLANS. INSULATE CONDENSATE LINE INSIDE BUILDINGS WITH 1" ARMAFLEX (ASTM E-84). REFRIGERANT PIPING: SHALL BE ACR TUBING, DRIED AND SEALED, HARD TEMPER COPPER WITH WROUGHT COPPER BRAZED JOINTS. ASTM-1388. COORDINATE AND VERIFY PROPER REFRIGERANT PIPE SIZES AND CHARGES WITH EQUIPMENT MANUFACTURER PRIOR TO ANY INSTALLATION. INSULATE SUCTION LINE WITH 1" ARMAFLEX. WRAP INSULATION OUTSIDE BUILDING ABOVE GROUND WITH ARMACELL # ARMACHECK 350 SILVER TAPE (UV -RESISTANT). DIMENSIONAL DATA: ALL DUCTWORK DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. SUPPLEMENTARY SUPPORTS: CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL EQUIPMENT AND MATERIALS, IN ORDER TO PROVIDE A "VIBRATION -FREE" RIGID INSTALLATION. DUCTWORK - GENERAL: FABRICATE AND INSTALL ALL DUCTWORK AND DUCT ACCESSORIES IN ACCORDANCE WITH THE LATEST EDITION OF APPLICABLE SMACNA STANDARDS, THE LATEST NFPA STANDARDS, AND THIS SPECIFICATION. THE MOST STRINGENT OF THESE SHALL BE THE MINIMUM STANDARD. MINIMUM OF 1" PRESSURE CLASS RATING FOR ALL DUCTWORK. ALL RECTANGULAR SUPPLY AND RETURN DUCTWORK TO BE R-6.0 RIGID FIBERGLASS DUCTBOARD (UL-181 AND 181A) WITH CLEANABLE AIRSIDE SURFACE AND EPA -APPROVED BIOCIDE (ANTI -MICROBIAL AGENT) IMPREGNATED IN MATTED AIR -SIDE SURFACE. ALL EXHAUST DUCTWORK AND FRESH AIR DUCTWORK SHALL BE GALVANIZED SHEET METAL STEEL OF LOCKFORMING GRADE CONFORMING TO ASTM A653 AND ASTM A924. DUCTWORK INSTALLATION: ALL INTERIOR DUCTWORK SHALL BE SEALED TO SMACNA CLASS (B) REQUIREMENTS WITH UL-181 MASTIC. PROVIDE DOUBLE THICKNESS TURNING VANES IN ALL NINETY (90) DEGREE SQUARE ELBOWS. CONTRACTOR SHALL FURNISH AND INSTALL ALL DUCT OFFSETS AS REQUIRED TO CLEAR INTERFERENCES WITH EXISTING BUILDING STRUCTURE, PIPES AND ELECTRICAL CONDUITS. FURNISH AND INSTALL ALL MISCELLANEOUS STEEL SUPPORTS REQUIRED FOR HANGING AND SUPPORTING DUCTWORK UNLESS OTHERWISE NOTED. VOLUME DAMPERS: DAMPERS SHALL BE PROVIDED IN THE BRANCHES OF THE DUCT SYSTEMS WHERE SHOWN ON DRAWINGS AND AS REQUIRED TO PROPERLY REGULATE THE VOLUME OF AIR DELIVERED TO OR WITHDRAWN FROM THE OUTLETS.. FLEXIBLE DUCTWORK: FLEXIBLE DUCTWORK MAY BE USED FOR THE FINAL RUNOUTS TO AIR OUTLETS, AND SHALL BE SIZED TO MATCH AIR OUTLET NECK. FLEXIBLE DUCTS SHALL NOT EXCEED 8-FEET LENGTHS. NO FLEXIBLE DUCTS SHALL PENETRATE FIRE -RATED WALLS OR CEILINGS. FLEXIBLE DUCTS SHALL COMPLY WITH THE PROVISIONS OF UL-181 CLASS 1 AIR DUCT MATERIAL. DUCTS SHALL BE FACTORY MADE AND COMPOSED OF: AN INNER FIBERGLASS WOVEN LINER, ENCAPSULATED HELIX COIL, A FIBERGLASS INSULATING BLANKET AND OUTER VAPOR BARRIER OF FIBERGLAS REINFORCED METALIZED FILM LAMINATE. PROVIDE THERMAFLEX MK-C FLEXIBLE DUCT OR APPROVED EQUAL (MIN. OF R-6.0). CARE IS TO BE TAKEN THAT ALL RUNOUTS OF FLEXIBLE DUCTS ARE INSTALLED AS STRAIGHT AS PRACTICAL AND FASTENED SO AS TO ELIMINATE AIR LEAKAGE. THE INSTALLATION SHALL CONFORM TO THE TECHNIQUES SHOWN IN THE UL APPROVED AND FACTORY -SUPPLIED INSTRUCTIONS. INSULATION: ASSURE ALL DUCTWORK IS SEALED PRIOR TO INSTALLING INSULATION. ALL METAL SUPPLY, RETURN, AND FRESH AIR (OUTSIDE AIR) DUCTWORK SHALL BE WRAPPED WITH 2" THICK FIBERGLASS BLANKET INSULATION WITH FSK (ASJ) FACING, MINIMUM INSTALLED R VALUE OF 6.0, AND FLAME SPREAD/SMOKE DEVELOPED RATINGS OF 25/50 BY ASTM E-84. INSTALL INSULATION ON DUCTWORK USING ADHESIVE AND/OR WELD PINS WITH WASHERS. SEAL ALL INSULATION JOINTS, SEAMS AND FASTENER PIN PENETRATIONS WITH VAPOR RETARDING PRESSURE SENSITIVE TAPE OR WITH GLASS FABRIC AND MASTIC. INSTALL TAPERED INSULATION TO THE TOP OF ALL EXTERIOR HORIZONTAL RECTANGULAR DUCTS WIDER THAN 24" BEFORE APPLYING THE FINISH INSULATION TO CAUSE A 1/2" PER FOOT SLOPE OF FINISH INSULATION TO SHED WATER. NOTE TO CONTRACTOR ON EXISTING CONDITIONS: CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND SURVEY ALL EXISTING CONDITIONS AND EQUIPMENT PRIOR TO SUBMITTING BID FOR WORK REQUIRED BY THESE DOCUMENTS. THIS INCLUDES ABOVE THE CEILING AND ON TOP OF THE ROOF. 2. CONTRACTOR SHALL REFER TO AND READ THROUGH ALL OF THE "CONTRACTOR'S SCOPE OF WORK" AS DEFINED IN THE BID SPECIFICATIONS AND DOCUMENTS AS PART OF THE BID PROCESS. 3. IF AT ANY TIME, THERE IS DISCREPANCY BETWEEN THE PLANS & SPECS, OR CONFUSION ZCONCERN OVER REQUIRED WORK, CONTRACTOR SHALL IMMEDIATELY NOTIFY ARCHITECT, ENGINEER, &ZOR OWNER AND GET DIRECTION BEFORE PROCEEDING WITH WORK IN QUESTION. 4. FOR ALL EXISTING EQUIPMENT TO BE RE -LOCATED &/OR RE -USED, CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION, SAFE STORAGE, & RE -CONNECTION OF SAID EQUIPMENT COMPLETELY. 5. FOR ALL EXISTING EQUIPMENT TO BE DEMOLISHED (I.E. DEMO) CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION, REMOVAL, & DISPOSAL OFF -SITE PER CODE, OF SAID EQUIPMENT COMPLETELY. HVAC LEGEND SUPPLY AIR DIFFUSER OR GRILLE RETURN/EXH. AIR REGISTER OR GRILLE NEW DUCTWORK, WITH SIZE LISTED FLEXIBLE DUCT DUCT SMOKE DETECTOR FIRE DAMPER ---M I SMOKE/FIRE DAMPER CID CONDENSATE DRAIN RFT REFRIGERANT LINE SET 0 THERMOSTAT BASE @ HUMIDITY SENSOR [T] REMOTE TEMPERATURE SENSOR CARBON DIOXIDE SENSOR CARBON MONOXIDE SENSOR 4+ AIRFLOW DIRECTION 44 1" DOOR UNDERCUT 0 ROUND, DIAMETER AFF ABOVE FINISHED FLOOR CFM CUBIC FEET PER MINUTE TYP TYPICAL - ITEM OR METHOD VID / MANUAL VOLUME DAMPER (W/HANDLE) MID V.&_ _Jq MOTORIZED DAMPER SUPPLY DUCT TAKE -OFF WITH SCOOP SUPPLY DUCT TAKE -OFF WITH VID DOUBLE THICK VANES SIDE DIFFUSER WITH VD (N) NEW (E) EXISTING SWITCH CONNECT NEW TO EXISTING WAVE GUIDE GRAVITY BACK -DRAFT DAMPER BAROMETRIC RELIEF DAMPER CONDENSATE LINE ON ROOF SUPPORTS DIFFUSER TAG EQUIPMENT TAG AIRFLOW --EQUIPMENT TYPE 400 CFM CD- 12"0 \_NECK \—EQUIPMENT MARK SIZE NUMBER C5 00 co 0 CO (0 Z z 0- U- c: F_ co co 0 CO — 0 ry BRANCH DUCT RUNOUTS: SHALL BE GALVANIZED ROUND (SNAPLOCK) SEAM LOCKED DUCTWORK WITH EXTERNAL FIBERGLASS WRAP INSULATION (R-6.0). NOTE: BRANCH DUCT RUNOUTS & FLEXIBLE DUCTS SHALL BE THE SAME SIZE DUCT AS THE DIFFUSER NECK CONNECTED TO, AS LISTED ON THE FLOOR PLAN. Job NUmbw GRILLES AND DIFFUSERS: ALL GRILLES AND DIFFUSERS SHALL BE INSTALLED WITH AN INSULATED BOOT OR BLANKET. PROVIDED A METHOD OF VOLUME CONTROL BY DEVICE ADJUSTABLE AT DIFFUSER FACE OR MANUAL VOLUME DAMPERS AT TAKEOFF BRANCHES. COORDINATE DIFFUSER AND GRILLE LOCATIONS WITH ELECTRICAL LIGHTING LAYOUTAND ARCHITECTURAL REFLECTED CEILING PLAN. CONTROLS: PROVIDE CONTROLS COMPLETE TO SUIT THE EQUIPMENT PROVIDED AND TO ACCOMPLISH THE SEQUENCE OF OPERATION AS REQUIRED BY PLANS AND SYSTEMS. LOCATE THERMOSTATS 48" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED. THERMOSTATIC CONTROLS SHALL BE PROGRAMMABLE TO INCLUDE ALL ITEMS REQUIRED BY FBC-ENERGY CODE SIXTH EDITION AND SHALL HAVE LOCKOUT FUNCTION WITH PASSWORD. MINIMUM FUNCTIONALITY SHALL INCLUDE: 7-DAY A WEEK PROGRAMMABLE CONTROLLER WITH SETBACKS UP TO 85—F AND DOWN TO 55-F, 10-HOUR BATTERY BACKUP, MANUAL OVERRIDE FOR 2-HOURS, AND AUTOMATIC STARTING (OPTIMUM START) ADJUSTABLE DAILY START TIMES. TESTING AND BALANCING: THE CONTRACTOR SHALL ENSURE THAT ALL DEVICES AND SYSTEMS ARE COMPLETE, TESTED AND BALANCED, AND READY FOR OPERATION WHEN THE FACILITY IS HANDED OVER THE OWNER. THE AIR CONDITIONING SYSTEM SHALL BE TESTED IN ACCORDANCE WITH CURRENT AABC OR NEBB OR NBC PROCEDURES. A CERTIFIED, WRITTEN REPORT SHALL BE SUBMITTED TO MECHANICAL ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL RECTIFY DISCREPANCIES BETWEEN THE ACTUAL INSTALLATION AND CONTRACT DOCUMENTS WHEN IN THE OPINION OF THE T&B AGENCY OR THE ENGINEER, THAT THE DISCREPANCIES WILL AFFECT SYSTEM BALANCE AND PERFORMANCE. SUBMITTALS REQUIRED: SUBMIT SHOP DRAWINGS FOR ALL MATERIALS, EQUIPMENT, AND SYSTEMS REQUIRED BY THESE DOCUMENTS (SEE ARCH. PLANS/SPECS FOR SPECIFIC FORMATTING), INCLUDING: SPLIT SYSTEMS TEST/BALANCE REPORT EXHAUST FANS DIFFUSERS AND GRILLES DUCTWORK, INSULATION AND ACCESSORIES (CONNECTIONS, MASTICS, ETC.) THERMOSTATS & CONTROLS SUBSTITUTIONS: CONTRACTOR SHALL PAY FOR ANY AND ALL ADDED COSTS ASSOCIATED WITH ANY SUBSTITUTION, INCLUDING SUBSTITUTIONS THAT REQUIRE CHANGES TO THE OTHER BUILDING COMPONENTS, SUCH AS ELECTRICAL, STRUCTURAL REINFORCING, CEILINGS, WALLS, ROOFS, ETC. THIS WILL INCLUDE ANY ENGINEERING/ARCHITECTURAL RE -DESIGN COSTS AS A RESULT OF SAID SUBSTITUTION. THESE COSTS SHALL NOT BE BORNE BY THE OWNER, ARCHITECT, NOR ENGINEER, REGARDLESS OF ACCEPTABILITY OF SUBSTITUTION. ENGINEER RESERVES THE RIGHT TO ACCEPT OR DENY ANY SUBSTITUTION THAT HE DOES NOT DEEM TO BE EQUIVALENT, AND CONTRACTOR SHALL PROVIDE SPECIFIED OR EQUIVALENT MATERIALS/EQUIPMENT AT NO ADDITION COST TO OWNER, SHOULD A SUBSTITUTION BE DENIED. GUARANTEE: THE ONE-YEAR GUARANTEE PERIOD SHALL NOT START UNTIL THE PROJECT IS FULLY COMPLETED AND THE CONTRACTOR HAS RECEIVED THE FINAL PAYMENT AND CERTIFICATION OF OCCUPANCY. ALL EQUIPMENT AND ALL WORK SHALL BE FULLY GUARANTEED, PARTS AND LABOR, FOR ONE YEAR FROM THE DATE OF THE CERTIFICATE OF COMPLETION. REPAIRS MADE DURING THIS PEROID MUST BE FULLY GUARANTEED FOR AN ADDITIONAL ONE YEAR PERIOD FROM THE DATE OF REPAIRS. IN ADDITION, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDING, AND ITS CONTENTS OR OTHER EQUIPMENT, CAUSED BY DEFECTS OR IMPROPER INSTALLATION OF EQUIPMENT OR MATERIAL INSTALLED. A 5-YEAR WARRANTY IS REQUIRED FOR COMPRESSORS. SPLIT SYSTEM SEQUENCE OF OPERATIONS: AHU TO SUPPLY AIR CONTINUOUSLY IN OCCUPIED MODE AND COMPRESSOR TO CYCLE TO MAINTAIN SPACE TEMPERATURE SETPOINT (COOLING — 75-F, HEATING 687). AHU TO CHANGE INTO UNOCCUPIED MODE VIA PROGRAMMING. DURING UNOCCUPIED MODE, AHU'S SUPPLY AIR AND COMPRESSORS SHALL CYCLE TO MAINTAIN SETBACK TEMPERATURE (COOLING — 807, HEATING 607). .MINI SPLIT SYSTEM SEQUENCE OF OPERATIONS: MAHU'S TO SUPPLY AIR CONTINUOUSLY IN OCCUPIED MODE AND COMPRESSOR TO CYCLE TO MAINTAIN SPACE TEMPERATURE SETPOINT (COOLING — 757, HEATING 687). MAHU'S TO RUN CONTINUOUSLY. EXHAUST FAN SEQUENCE OF OPERATION: REFER TO FAN SCHEDULE FOR INTERLOCKS AND OPERATION PARAMETERS. STEPANEK—L k2tAmA N DASSOCIATES 2257 TWELVE OAKS WAY, SUITE 103 WESLEY CHAPEL, FL 33544 PH (813) 991-1248 REGISTRY # 8397 21-143 Revkdons \N D No 56189 39 STATE 0 F R 0 itillill NAk- Sh"t No. mi MATTHEW D. LEWIS, P.E. FL LIC#56189 -1 T__ 1 11 1 L L kmm Date 09-0" (D 1-1/2" HANGER STRAPS; MAX. 10' SPACING 0 ROUND SNAPLOCK DUCT WITH WRAP INSULATION (D TAKE -OFF OR SPIN -IN FITTING W/ VOLUME DAMPER. (DON'T USE VOLUME DAMPER ABOVE GYP CEILINGS) (D PROVIDE PLASTIC ELBOW STRAIGHTENER TO ELIMINATE KINKS AT ELBOWS FLEXIBLE DUCT - PROVIDE FLEXFLOW, OR EQUAL. METAL COLLAR WITH BAND CLAMP, SCREWED (3) PLACES AND TAPED TYPICAL BOTH ENDS OF FLEX DUCT. INSULATED FLEXIBLE DUCT, MAXIMUM 6' LENGTH. INSTALL FLEX -DUCT AS STRAIGHT AS POSSIBLE. NO BEND OVER 90% NO CRUSHING OF FLEX -DUCT. 0 2" WRAP INSULATION OVER BACK OF DIFFUSER SUPPLY DUCT AND DIFFUSER RUN -OUT DETAIL SCALE: NONE 1/2"x22 GA. WIDE BAND CLAMP 1-1/2"x22 GA. WIDE 1-1/2" x 22 GA. BAND CLAMP SADDLE HANGER AND SUPPORT FOR ROUND AND FLEXIBLE DUCTS NO SCALE 0.25 D FANGULAR DUCT >1 n D n D cn BUTTERFLY TYPE DAMPER IN CONICAL SPIN COLLAR WITH QUADRANT. PROVIDE DAMPER AT ALL BRANCH TAKE -OFFS. < ROUND DUCT BRANCH DUCT DETAIL NOT TO SCALE 12—GAUGE HANGER WIRE (TYPICAL) I / Z111- E TTOTAAIL HAN =GE�R����. ll-::� EXTENSION = 3" E, MAXIMUM HANGER SPACING 8-FT UNISTRUT OR 3"X2" CHANNEL (TYPICAL) 3" HANGER AND SUPPORT FOR FIBROUS GLASS DUCTS NO SCALE BACKDRAFT DAMPER (INTEGRAL TO CAP) OUTSIDE AIR DUCT ----- SEE PLANS FOR SIZE/ROUTING SEAL WALL OPENING WEATHERTIGHT WITH CAULKING EXTERIOR WALL WALL CAP WITH WEATHERHOOD & INTEGRAL BIRD SCREEN MFG = BROAN # 613 (ALL ALUMINUM CONSTRUCTION) MOUNT TO WALL WITH #10 TECK SCREWS EXHAUST AIR WALL CAP DETAIL SCALE: NONE 1/4X20 TPI "ALL THREAD" SUPPLIED BY MC. __ CEILING EXHAUST FAN 1114, /,/-- BACKDRAFT DAMPER EXHAUST DUCT SEE PLANS FOR SIZE AND ROUTE CEILING FAN DETAIL SCALE: NONE THOMPSON METAL, OR EQUAL GALVANIZED METAL GOOSENECK ANCHOR CAP TO ROOF W/ #10 TECK SCREWS ON 12" CENTERS — ALL SIDES AIR INTAKE FOP FRESH AIR ROOF CAP DETAIL SCALE: NONE CONDENSING UNIT , CUTD" BY MIAMI TECH OR EQUAL. FLORIDA PRODUCT 1-1/2" APPROVAL #19731.1—R2 00 0 4"xl-1/2"xl4GA CLIP (4) #10 SS-410 TEK SCREWS TO CASING 0 (1) 1/4" x 1-3/4" LONG TAP —CON 0 0 CONCRETE ANCHORS OR EQUAL TO CONCRETE PAD OR L (2) #14 SS TEK SCREWS TO RAIL CONCRETE PAD 1 /2" NEOPRENE PAD UNDER EACH CLIP OR ROOFSTAND HEAT PUMP CONDENSER TIE -DOWN DETAIL SCALE: NONE PROVIDE (1) TIE -DOWN CLIP PER CORNER ON EACH SIDE OF UNIT (2 PER SIDE, AND 8 PER UNIT) SLOPED TOP TO SHED RAIN INSULATED PIPING TO U N ITS ANCHOR FLANGED SIDES TO WALL AT 18" INTERVALS AND SILICONE CAI ALL EDGES AT WA 22—GAUGE GALV. SHEET METAL. FOAM SEAL BOTTOM PIPING TO UNITS-/ AFTER INSTALLATION TO PREVENT BIRDS AND INSECTS NESTS. REFRIG. PIPING WALL COVER DETAIL SCALE: NONE STEPANEK-L ANDASSOCIATES )2,257 TWELVE OAKS WAY, SUITE 103 WESLEY CHAPEL, FL 33544 PH (813) 991-1248 REGISTRY # 8397 21-143 co LO _(0 co o M < u- z z E M 00 I _J ;0 cy) � cl) CD (D 0) Q) -0 0 Job Nwiber Rovkikxw %%011111111111'r /.*, \N D EN No 56189 13 - STATE 0 F 0 R ,4, /ONA 1.41,111111 1 Sh"t No. M2 MATTHEW D. LEWIS, P.E. FL LIC#56189 Ism* Date c: OD Lf) 0 VENTILATION AIR SCHEDULE AHU-1 VENTILATION AIR SCHEDULE AHU-4 Z m_j z CL LL :) E REQUIRED 0 ZONE (D SYSTEM(j) REQUIRED G) REQUIREDC1 PROVIDED REQUIRED (j) ZONE@ SYSTEM@ REQUIRED (a) REQUIREDC PROVIDED (D M (0 SPACE FUNCTION REQUIRED NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST SPACE FUNCTION REQUIRED (:D NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST co AREA OUTSIDE AIR AREA OUTSIDE AIR OR EXHAUST _j PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) (SQFT) AIR (CFM) AIR (CFM) (SQFT) AIR (CFM) AIR (CFM) co OFFICES/EXAMS 602 5 CFM CFM -PERSONS) OFFICES/EXAMS 903 5 CFM + 0.06 CFM 4.5 ( 5-PERSONS) 1.0 1.0 77 (D + 0.06 3 ( 5 1.0 1.0 51 PERSON SQFT 1,000-SQF-T -0 PERSON SQFT 1,000-SQFT 0 CFM RESTROOMS 0 70 CFM 2-T ILETS 140 140 V� ry WAITING LOBBY 345 7.5 CFM + 0.06 10.4 (30-PERSON 1.0 0.9 98 TOILET PERSON SQFT 1,000-SQFT ci��� - - - - , CFM �3 5 1.0 1.0 32 HALLWAYS 310 0.06 CFM 1.0 1.0 340 RECEPTION AREA 152 5 CFM + 0.06 4.6 O-PERSON! SQFT PERSON " 1,OOO-SQFT BREAKROOM 85 7.5 CFM + 0.18 CFM 6 (70-PERSONS) 1.0 0.8 60 -- RESTROOMS 0 70 CFM 2-TOILETS 140 140 PERSON SQFT l'OOO-S0FT TOILET SYSTEM POPULATION, Ps: TOTAL ZONE POPULATION, I Pz 10.5 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou / MIN Ev) (CFM) 174 HALLWAYS 268 0.06 CFM 1.0 1.0 16 SQFT I I I I OUTSIDE AIR INTAKE UNCORRECTED, (Vou) (=DxY-RpPz+Y-RaAz) 139 PROVIDED OUTSIDE AIR INTAKE (CFM) 175 SYSTEM POPULATION, PS: 17 TOTAL ZONE POPULATION, I Pz 17.9 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou / MAX Ev) (CFM) 213 z �l I - OCCUPANT DIVERSITY, D (=Ps/ I Pz) 0.76 TOTAL PRESSURE PROVIDED INT.- PROVIDED EXH. (CFM) OUTSIDE AIR INTAKE UNCORRECTED,(Vou) (=DxY-RpPz+ 92 PROVIDED OUTSIDE AIR INTAKE (CFM) 215 T I 1 NOTE : CD REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. OCCUPANT DIVERSITY, D (=Ps/Y-Pz) 0.95 _FTOTAL PRESSURE PROVIDED INT.- PROVIDED EXH. (CF7M)75 NOTE REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. VENTILATION AIR SCHEDULE AHU-5 FUNCTION REQUIRED (j) REQUIRED G) ZONE 0 SYSTEM 0 REQUIRED 0 REQUIREDC1 PROVIDED SPACE AREA OUTSIDE AIR OR EXHAUST NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST VENTILATION AIR SCHEDULE AHU-2 (SOFT) PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) AIR (CFM) AIR (CFM) OFFICES/EXAMS 361 5 CFM + 0.06 CFM 1.8 ( 5-PERSONS) 1.0 1.0 31 FUNCTION REQUIRED REQUIRED @ ZONE T SYSTEM 0 REQUIRED 0 REQUIREDC PROVIDED PERSON SQFT 1,000-SQFT SPACE AREA OUTSIDE AIR OR EXHAUST NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST RESTROOMS 0 70 CFM 1 -TOILETS 70 70 (SQFT) PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) AIR (CFM) AIR (CFM) TOILET OFFICES/EXAMS 639 5 -��-FM + 0.06 CFM 3.2 ( 5-PERSONS) 1.0 1.0 54 PERSON SQFT HALLWAYS 152 0.06 CFM 1.0 1.0 9 1,000-SQFF SQFT 0 CFM CFM RESTROOMS 0 7 1 -TOILETS 70 70 BREAKROOM 100 7.5 CFM + 0.18 7 (70-PERSONS) 1.0 0.9 71 TOILET I PERSON SQFT 1,000-SQFT HALLWAYS 247 0.06 CFM 1.0 1.0 15 SQFT SYSTEM POPULATION, Ps: TOTAL ZONE POPULATION, I Pz 8.8 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou MIN Ev) (CFM) 103 STORAGE 95 0.06 CFM 1.0 1.0 6 SOFT OUTSIDE AIR INTAKE U N CORRECTED, (Vou) (=DxY-RpPz+ 93 PROVIDED OUTSIDE AIR INTAKE (CFM) 105 SYSTEM POPULATION, Ps: 3 TOTAL ZONE POPULATION, Y, Pz 3.2 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou MIN Ev) (CFM) 75 OCCUPANT DIVERSITY, D (=Ps/Y-Pz) 0.68 TOTAL PRESSURE PROVIDED INT.- PROVIDED EXH. (CFM) 35 7� OUTSIDE AIR INTAKE U N CORRECTED, (Vou) (=DxY-RpPz+Y-RaAz) 75 PROVIDED OUTSIDE AIR INTAKE (CFM) 150 NOTE (j) REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. OCCUPANT DIVERSITY, 1.0 TOTAL PRESSURE = PROVIDED INT.- PROVIDED EXH. (CFM) 8 D (=Ps/ I Pz) -0 NOTE REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. VENTILATION AIR SCHEDULE AHU-6 REQUIRED ZONE SYSTEM REQUIRED (j) REQUIREDC1 PROVIDED FUNCTION REQUIRED (j) SPACE AREA OUTSIDE AIR NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST (SQFT) PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) AIR (CFM) AIR (CFM) VENTILATION AIR SCHEDULE AHU-3 ENTRY LOBBY 110 5 CFM + 0.06 CFM 1.1 (10-PERSONS) 1.0 1.0 12 PERSON SQFT 1,000-SQFT FUNCTION REQUIRED REQUIRED ZONE 0 SYSTEM@ REQUIRED 0 REQUIREDC1 PROVIDED SPACE AREA OUTSIDE AIR NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST OFFICES 460 5 CFM + 0.06 CFM 2.3 5-PERSONS 1.0 1.0 39 PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR PERS SQFT 1,0 (SQFT) AIR (CFM) AIR (CFM) (CFM) ON 00-SQFF CFM -PERSONS) WAITING LOBBY 144 7.5 CFM + 0.06 CFM 4.3 (30-PERSONS) 1.0 1.0 41 OFFICES/EXAMS 660 5 CFM + 0.06 3.3 5 1.0 1.0 56 PERSON SQFT 1,000-SQFF PERSON SQFT 1,000-SQFT RESTROOMS 0 70 CFM 1 -TOILETS 70 70 WAITING LOBBY 300 7.5 CFM + 0.06 CFM 9 030-PERSONS) 1.0 0.9 86 TOILET PERSON SQFT 1,000-SQFT HALLWAYS 102 0.06 CFM 1.0 1.0 6 RECEPTION AREA 120 5 CFM + 0.06 CEM 3.6 �30-PERSON'�) 1.0 1.0 25 SQFT PERSON " l'0OO-SQFT RESTROOMS 0 70 CFM 1 -TOILETS 70 70 SYSTEM POPULATION, Ps: 7 TOTAL ZONE POPULATION, I Pz 7.7 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou MAX Ev) (CFM) 104 1 TOILET I I I I I I Job NWTibw HALLWAYS 240 0.06 CFM OUTSIDE AIR INTAKE UNCORRECTED, (Vou) (=DxY-RpPz+Y-RaAz) 94 PROVIDED OUTSIDE AIR INTAKE (CFM) 110 14 SQFT 1.0 1.0 OCCUPANT DIVERSITY, D (=Ps/ I Pz) 0.9 -F AL PRESSURE PROVIDED INT.- PROVIDED EXH. (CFM) 40 TOT Revk*xw SYSTEM POPULATION, Ps: 15 TOTAL ZONE POPULATION, I Pz 15.6 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou / MAX Ev) (CFM) 195 NOTE REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. OUTSIDE AIR INTAKE UNCORRECTED,(Vou) (=DxY-RpPz+Y-RaAz) 1 175 PROVIDED OUTSIDE AIR INTAKE (CFM) 195 OCCUPANT DIVERSITY, D (=Ps/ I Pz) -7 0.95 TOTAL PRESSURE PROVIDED INT.- PROVIDED EXH. (CFM) 125 NOTE REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. NOTE ON OVERALL BUILDING PRESSURE WITH ADDED FANS: �NS* THERE ARE ADDITIONAL EXHAUST FANS SHOWN BUT NOT REQUIRED BY CODE, AND ONLY FOR ODOR/HEAT CONTRJOL. WITH ALL CONDITIONS OF FANS RUNNING, THE BUILDING WILL MAINTAIN PRESSURE AS FOLLOWS: WITH ALL (8) EF-1 RESTROOM FANS ON = +390-CFM WITH ADDED (1) EF-2 FAN ON +340-CFM WITH ADDED (2) EF-3 FANS ON +240-CFM WITH ADDED (4) EF-4 FANS ON +40-CFM �A�_-\N D G E N No 56189 STATE 0 0 0 R STEPANEK-L '0 JF.r frill% ANDASSOCIA , L­� - I k2257 TWELVE OAKS WAY, SUITE 103 Smt No. WESLEY CHAPEL, FL 33544 PH (813) 991-1248 REGISTRY # 8397 21-143 M3 MATTHEW D. LEWIS, P.E. FL LIC#56189 NEW HEAT PUMP CONDENSING UNIT SCHEDULE GENERAL NOMINAL CAPACITY COOLING COMPRESSOR CONDENSER FAN SINGLE PT. POWER MARK TOTAL kBtu/hSENSIBLE kBtu/h POWER V/0 OTY RLA EA. LRA EA. QTY FLA EA. MCA (A) MOCP (A) MFG. MODEL # REFRIGERANT SEER AMBIENT HSPF NOTES HP-5 & HP-6 36 24 208-230/1 1 1 18.5 83.0 1 0.6 23.7 40 1 CARRIER 25HCB6-36 R-410A 16 95*F 8.5 009(�) NOTE: 0 PROVIDE REFRIGERANT LINE SETS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS & SIZING GUIDELINES. (1) PROVIDE WITH TXV, LOW AMBIENT KIT, SIGHT GLASS, FILTER DRIER, & 5-MINUTE ANTI -CYCLE TIMER. DISCONNECT TO BE PROVIDED BY ELECTRICIAN. SECURE UNIT TO EXISTING CONCRETE PADS WITH FL.PROD.APPROVED TIE DOWN CLIPS (SEE DETAIL.) PROVIDE 2-STAGE COMPRESSOR AND HhL GUARD AROUND CONDENSER. NEW AIR HANDLER UNIT SCHEDULE GENERAL FAN COOLING COOLING CAP HP HEATING CAP ELECTRIC HEAT SINGLE POINT POWER MARK SUPPLY CFM OUTSIDE AIR CFM ESP IN. WG. POWER V/0 TONS (NOM.) MOTOR HP ENT AIR TOTAL kBtu/h A SENS. kBtu/h TOTAL kBtu/h kW (@ RATED VOLTS) MCA MOCP A WT LBS FILTER EFFIC. M FG. MODEL NOTES DB WB AHU-5 - - - - - - - - - - - - - 1,100 - - - - - - t__105__I__0.8__t208-230 1 /11 - - - - - - - 3.0 0.75 76.9 64.2 4.6 22.8 - - - - - I - - - - - - - - 3.8/5.0 - - - - - 26.0/28AZj-\ 30 - - - - - - - - --- 172 - - - MERV-7] - - - - - - CARRIER] - - - - - - - FV4CNBOO5 - - - - - - - - - I nl 0 0 L_ �:� AHU-6 1,100 110 1 0.8 1 208-230/]l � 3.0 0.75 77.0 64.3 1 33.1 23.4 13.0/17.1 3.8/5.0 26.0/28.4 30 172 MERV-7 CARRIERTFV4CNB005TT 0 9 NOTE: PROVIDE WITH 2-STAGE PROGRAMMABLE HEAT PUMP THERMOSTAT WITH EMERGENCY HEAT MODE. PROVIDE SECONDARY DRAIN PAN UNDER UNIT WITH FLOAT SWITCH WIRED TO SHUT DOWN FAN MOTOR. DISCONNECT TO BE BY ELECTRICIAN. PROVIDE WITH FULLY INSULATED (1" MINIMUM) GALVANIZED STEEL CABINET, WITH PREPAINTED FINISH. PROVIDE WITH EMERGENCY ELECTRICAL HEATER AND SINGLE POINT POWER CONNECTION TO UNIT (AHU & HEATER). EXISTING SPLIT SYSTEM UNIT SCHEDULE GENERAL HEATING COOLING SUPPLY OUTSIDE FILTER E A EAT * F T TONS kW EMERG. HEAT PUMP TOTAL SENS. AMBIENT REFRIG MARK CFM AIR EFFIC b (db/wb) d b W (NOM.) HEATING TOTAL MBH MBH MBH M FG. AHU MODEL HP MODEL AGE RATING 'F TYPE NOTES CFM A AHU-1 HP-1 cl 1�90 0 215 MERV 7 .0 77.5/65.0 5/65 77 ��q F766 5 5-KW ESTIMATED 62.0 58.5 41.0 CARRIER 2019 95 R-41 OA CH1 4NBO60 AHU-2 HP-2 1,810 150 MERV 7 76.6/63.3 6.3 . / 3 5 5-KW ESTIMATED 62.0 56.2 42.0 CARRIER 2019 95 R-410A CH14NBO60 AHU-3 HP-3 1,860 195 MERV 7 77.2/64.5 5 5-KW ESTIMATED 62.0 57.6 40.5 CARRIER 2019 95 R-410A @ CH14NBO60 AHU-4 HP-4 1,800 175 MERV 7 770/64.2 ) 5 5-KW ESTIMATE& 62.0 55.3 39.5 CARRIER 2018 95 R-410A (D 0 0 CH14NBO60 NOTES: Ul PROVIDE WITH NEW PROGRAMMABLE 7-DAY THERMOSTAT AHU ACCESS LIMITED - EMERG HEAT AND AHU NAMEPLATE ESTIMATED AND MUST BE FIELD VERIFIED PRIOR TO ANY WORK. SERVICE UNIT COMPLETELY (SEE NOTES). .SERVICE WORK REQUIRED: CONTRACTOR SHALL SERVICE EXISTING (TO REMAIN) AIR HANDLERS AND HEAT PUMP CONDENSING UNITS COMPLETELY AND REPLACE ANY DEFECTIVE PARTS AS NEEDED. PROVIDE SERVICE REPORT TO PROJECT MANAGER. SERVICE WORK SHALL INCLUDE AT A MINIMUM: LUBRICATE ALL BEARINGS, REPLACE ANY BELTS, RE -CHARGE CIRCUITS OR REPAIR REFRIGERANT LEAKS (RE-CLAIM / RE -CHARGE CIRCUITS IF NEEDED), REPLACE FILTERS, CLEAN EVAP COILS, CLEAN DRAIN PAN, AND CLEAN/REPAIR INSULATION ON INSIDE OF UNITS. CONDENSATE PIPING INSULATION SHALL BE UPDATED TO ENSURE FULLY INSULATED PIPING INSIDE BUILDING. NEW AIR DEVICE SCHEDULE GENERAL CONSTRUCTION MARK TYPE FUNCTION FRAME SIZE PATTERN MATERIAL FINISH M FG. MODEL NOTES CD CEILING DIFFUSER SUPPLY 24x24 LOUVERED FACE ALUMINUM WHITE PRICE AMD CD2 CEILING DIFFUSER SUPPLY 12X12 LOUVERED FACE ALUMINUM WHITE PRICE AMD 0) RGC RETURN GRILLE RETURN 24X24 BLADES ALUMINUM WHITE PRICE 630DAL G) LSG LVRD SOFFITT GRILL EXHAUST 3X10 BLADES ALUMINUM WHITE GREENHECK EL-10X3 @ NOTES: (j) PROVIDE WITH OPPOSED BLADE DAMPER. M NEW FAN SCHEDULE GENERAL CONSTRUCTION MARK CFM SONES ESP (IN-WG) ELEC. MOTOR DRIVE TYPE FAN MANUF. INTERLOCK WITH MODEL WEIGHT (Ibs) NOTES EF-1 70 2.0 0.375 120/1 -PH 41 WATTS DIRECT CEILING COOK LIGHTS GC- 148 15 EF-2 r5o 2.2 0.375 120/1 -PH 41 WATTS DIRECT CEILING COOK THERMOSTAT GC-148 15 G) (2) EF-3 50 2.0 0.375 120/1 -PH 41 WATTS DIRECT CEILING COOK LIGHTS GC-148 15 0) EF-4 50 2.2 0.375 120/1 -PH 41 WATTS DIRECT CEILING COOK WALL SWITCH GC-148 15 00 NOTES: PROVIDE FAN WITH CEILING GRILLE, FAN SPEED CONTROLLER, GALV.METAL HOUSING, GEMINI ISOLATOR KIT AND BACKDRAFT DAMPER. DISCONNECT BY ELECTRICIAN. INTERLOCK AS SCHEDULED TO BE BY ELECTRICIAN. COOLING ONLY THERMOSTAT FURNISHED BY MECHANICAL AND WIRED BY ELECTRICIAN. STEPANEK-L 1% ANDASSOCIATES �IF2257 TWELVE OAKS WAY, SUITE 103 WESLEY CHAPEL. FL 33544 PH (813) 991-1248 REGISTRY # 8397 21-1 43 0 c t "o (D CO Lo to 0 CO 0 CO (0 0 N < U_ Z z cl. U_ 0 :D E F- N 0 (0 0) 0 Job Number f_-V�l D N,� No 56189 % k441 % STATE OR 0 A\ 0 R `elS/0NA 1111tills)l, MATTHEW D. LEWIS, P.E. FL LIC#56189 6� EX 51 ELEG [2:0] A C 3 a F20] 107 EXISTING CONDENSERS 3.4,5,6 TO BE REUSED. 107 �AC AC P 81 F, BI FE ELEC STORAG 0- 9 �TO L;Z N UTILITY ELEG H L- BREAK ROOM Ll PEDI EXAM DOCTOR n Eh 77 Eb, 2] 02 7] F J1z' :02 P E BULKHEAD SIJLX�4EAD (E)AHU ABOVE ABOVE E AH,, E HU .. . . .. . ..... . . ..... ... . z Efl I Fill 141 T=-= '7 '7 n2 PI n2 j 18 El ''I T -1 T T 5 L -1 3 (E)SINK L LAB F, -J OFFICE ADMIN MED 0 ICE N N QF C DOCTOR 1-J, TOILET . . ..... ... . PEDI EXAM D2 LL- �22 PEDI LOCKABLE NURSES F 20 ADMIN MED J F71 TOILET FAMILY 0 QEF—ICE auu—pp-L-�� 14 POCKETI IDOOR I NURSES STATIO FAMILY< PEIDI V4ATER �XA M EXA BOTTLE 5ULKkEAD 5 it I I COPY —T— Eal- RECEET/ ADMIN A50VE -t,7] ;E3CAL- EXISTING 4 AIRHANDLERS TO REMAIN. W -)At-iU 'y It J REMOVE ALL DUCTWORK, FANS AND DIFFUSERS. REFRIGERANT LINES TO REMAIN. 51JLK�-IEAD PEDI ABOVE EXA El t DOOR PLAY ARE I-F-I To KIDS TI In 1�h Erl Ck �22 El 21 F Ifl Efl- Efl- FAN I LY\\ El [2] ELD �71 FAMILY BLOOD FAMILY PEDIATRIC PEDI 07 V4AITIN E—XA-M EXAM !�4AIJIN E� NEV45ORN L L K I E)S PLAY AREA L-7, 03 NENBORNS �171 fj-'-7 1 Al 1 1 11 U I flr7-7 IZI 1147 7 ZZIA z Eal L-181 Fl-81 F 81 N8 — — — — — — — — — — — — — — — — — — — — — — — — — — --- — — — L ---------- I T `�] I Tr \ MECHANICAL DEMOLITION PLAN SCALE: 3116" = V-0- I—E] STEPANEK- L ANDASSOCIATES )2257 TWELVE OAKS WAY, SUITE 103 WESLEY CHAPEL, FL 33544 PH (813) 991-1248 REGISTRY # 8397 21-14 (D a) 00 0 2 LL a) z a LL z D E (a (0 a) 14 '0 (D 0 Job Nuffdw 0 NIL ki �-_\N D C EN No 56189 STATE 01-i 0 R "; et S/ 'FlIONA 0111111 , Sh"t No. MMM5 MATTHEW D. LEWIS, P.E. FL LIC#56189 L A V 1774�W nNlj@� MECH 40 CFM CD2-6"O N�� NEW OPERATORY 4 150 CFM CD-8 �) 0 LAB/ STERILIZATION 110 CFM NEW BREAK CD-6"O ROOM 1 STOR 110 CFM W1 30 CFM RGC-14xl4 Vli \CD2-6"05_,� 06 NEW OPERATORY 3 CT 150 CFM CD-8"O 90 CFM �C OD -(61D� "0 NEW OPERATORY 2 170 CFM CD-8"O 170 CFM RGC-14x14 14X6 1 4X6 180 CFM RGC-14xl4 PRIVATE 180 CFM OPERATORY1 CD-8"O CORR C Inx 0 CFM D-6"o 90 CFM 605 F ((—E—)C U_— 4—> ((E)CU-3) ((E)CU-2 > NEW FAMILY FAMILY Z� PEDIATRIC EXAM 3 EXAM 2 PROVIDERS 100 FM PROVIDERS 160 CFM EXIST IT EXIST EXAM 6 1 IREAK 2 160 CFM 120 CFM 130 CFM 50 CFM �CD- 0 : 100 FM OFFICE 1 PEDIA UTILITY CD-8"O 180 CFM OFFICE 2 CD-8"O TRIC CD-8"O CD-8"O CD-8"O 150 CFM CD-8"O CD- "0 160 CFM ADA EXAM 7- 100 CFM 200 CFM 150 CFM 80 CFM D-8"O TOILET 3 IS441 C M RGC-1 414 1 CD-6"O -14x14 CD-8"O CD-8"O R G C 0 1 5 CFM 150 CF 180 CFM 160 CF 160 CFM 1 130 CFM 200 CFM 150 CFM C 20 FM C RGC-14x1 F ILY RGC-14x14 C RGC-14xl4 RG 14 RGC 414 50 CFM: RG'C- 1 4x C 14X12 RGC-14x14 GC 14 14X10 RG -1404 280 C M F7 �_ - I EXAMA F, 110.mg==�2jm N - I N N 180 C RGC-1 x1 14x14 4xl 8 14X10 14X8 14X10 14X6 ADIATRIC CD-8 0 CFM I AVO lAvIr- ox 1 13 "FM IL 22X 2 u mmlu mi I-, CD-8tp� CAM 0 0 EXAM 4 A, T 4 —OR RI 100 CFM 5 C �, e Z� 100 CFM� 'j, ORRIDOR G 6 COR K 40 CFM 100 CFM 12 AHUEq2 505 FM _tj4X2 2X D-6"O C RGC-14xl4 570 CFM 120 CFM 7f_1 1,1 X6 CD-6"O CD-6"O �,RGC— 8x18, EXIST ELEC CD-8"O 14 S 18X18 F\ lox �0 CFM PROVIDERS 14X12 22X22 100 CFIA 12 100 CFM 1%, 0"'� I 1 \ RGC-14xl CD-6"O 140 CFM A 120 CFM CD2-6"O 'Exisi C, 4r] GC-14x14 �2X22 14X22 14X19 Ai/ADA R BJ STAFF PANO ADMIN. Z� t:1 0 CFM ,:40 �FM C D ;-8 " 0 14X12 T do ADA PATIENTS CFM '+A Z_ z_uu urm —8"0 IkIn 0 22V21 11 CD 00 TOILET t_rlk.�tz z C Nb,(- — 1 4x 14 IVIE:u u urm 120 CFM 00 CORR D X RRI L CFM co XIST ADMIN y SUPPLY 14X CD2-6"O 80 CFM RGC-14xl4 00 -6" -14y14 CFMF FAMILY OFFICE CORR F 90 CFM X CD-6"O X CD 8"0 AD 8� 50 CFM 14X6 F��_ gA D A, 120 CFM EXAM 5 120 CFM CD-6"O CD2-6"O Xis OFFICE 110 CFaQl-LE:T 2 RGC-14xl CD-8"O 100 CFM C ORR H BLOOD 200 CFM 100 CF1 140 CFM DRAW RGC-14x14 P STOR 3 M OFFICE 1 MANAGER gj-6"O 80 CFM-,-, CD-6"O 100 CFM 100 CFM CD-6"O EXIST 120 CFM \\�D-6) CD-6"O CD�8"O 100 CFMI NURSES AHU-6_� 120 CFM N_�l 14yi 80 CFM i 100 CFM CD-6"O STATION \L TC)II PT r� R r, (', - A -I)- — — EDIATRIC EXAM 4 1ju 1.11 Ivi 11 11 1 UILL I I STOR CD-8"O RGC-14xl4 ADA 600 CFM 1 120 CFM TOILET 6 RGC-18x18 HC71- - 1 4x 14 14X6 Vil 600 C RGC-1 RG C EXI 17 1 P CORR M Z� 130 CFM EXISTIN 14X10 140 CFM CD-6",O P0 PEDIATRIC 50 CFM RGC-14xl4 KIDS WAITING' 100 CFM CD2-6"O PLAY AREA 200 CFM RGC-14x14 al 50 CFM EXPANDED 200 CFM 130 FM 120 CFM 120 CFM FAMILY FAMILY 50 CFM FAMILY CD-8"O CD-8"O CD2-6"O 130 FM DENTAL 130 CFM 140 CFM EXAM 7 120 CFM EXAM 8 130 CFM C 110 WAITING 200 CFM 100 CFM CD-8"O CD-8"O CD2-6"0 CD-8"O ENTRY CD- "0 WAITING CD-8"O CD-8"O CD-8"o CD-8"O CD-6"O PEDIATRIC PEDIATRIC LOBBY 'EXISTING EXAM 1 EXAM 2 VITALS =�REFER TO ARCHITECTURAL DEMO SHEET "Al FOR REFER TO SHEET "M7" FOR EXHAUST SYSTEMS, ALONG P Oj PROJECT PHASING REQUIREMENTS. WITH FRESH AIR AND PIPING REQUIRED. MECHANICAL CEILING PLAN SCALE: 3/16" = 1'-0" KEY NOTES ON REMODEL PLAN: (D EXISTING AIR HANDLER A/C UNIT TO REMAIN. SERVICE AND CLEAN HVAC SYSTEM. FRESH AIR INTAKE WITH MANUAL VOLUME DAMPER AND BACKDRAFT DAMPER. COORDINATE SHARED ROOFCAP INSTALL TO ENSURE MIN. 10-FT CLEAR FROM EXHAUST ROOF VENTS. ROUTE 1." CONDENSATE LINE FROM AHU'S THROUGH ATTIC TO BACK OF THE BUILDING. CONNECT TO 1.5" MANIFOLD AND SPILL IN GRASSY AREA. COORDINATE THERMOSTAT SENSOR LOCATION WITH FURNITURE LAYOUT AND OWNER'S REP PRIOR TO ROUGH -IN OF BACKBOX AND WIRE. NEW AIRHANDLER. (SEE DETAIL) VOLUME DAMPER IN EACH BRANCH SUPPLY & RETURN DUCT (TYPICAL THROUGHOUT). LOCATE ABOVE LAY -IN CEILING ONLY. DAMPER TO BE ACCESSIBLE AFTER CONSTRUCTION IS COMPLETED. ROUTE REFRIGERANT PIPING THROUGH ATTIC & DOWN AT EXTERIOR WALL. SEAL WALL PENETRATION WEATHERTIGHT. PROVIDE A METAL COVER AROUND THE REFRIGERANT LINE SET. PLACE CONDENSERS ON EXISTING PAD AND SECURE PER DETAIL. EXISTING CONDENSERS, SERVICE AND CLEAN COILS. Z� 13 m (D co 0 N L.L < Z M -i Q) z aLL D E o M 00 0 CO CO M, Q) Lo 0 Job Nkxnbw Revkdons zl� *-oe-21 ,%%% tijillf j___ - ____ i Vq. No 56189 _33 S) TAT E r) 0 V, 's STEPANEK—L �'Ofj,ONAI A ill I I liffik 11)MIN! u r__A I L--) -- — ------ , 92257 TWELVE OAKS WAY, SUITE 103 gmt No. WESLEY CHAPEL, FL 33544 PH (813) 991-1248 JOWL REGISTRY # 8397 21-143 mu MATTHEW D. LEWIS, P.E. FL LIC#56189 kais Date 09-0" ,I MECH 6 0 --7\ \Z-./ STOf NEW OPERATORY 4 NEW WE A\ LOCATE ALL NEW EXH WALL DO NOT CROSS ELEC CAPS TO AVOID THE EXISTING —USE PANELS IN THIS AREA OF GUTTER — DO NOT RE BACK WALL EXISTING VENTS. PROVIDE NEW. MECHANICAL EXHAUST & PIPING PLAN SCALE: 3/16" = 1'-0" 1PROJECT PHASING REQUIREMENTS.. MMMI (DEXISTING AIR HANDLER A/C UNIT TO REMAIN. SERVICE AND CLEAN HVAC SYSTEM. FRESH AIR INTAKE WITH MANUAL VOLUME DAMPER AND BACKDRAFT DAMPER. COORDINATE SHARED ROOFCAP INSTALL TO ENSURE MIN. 10—FT CLEAR FROM EXHAUST ROOF VENTS. ROUTE l." CONDENSATE LINE FROM AHU'S THROUGH ATTIC TO BACK OF THE BUILDING. CONNECT TO 1.5" MANIFOLD AND SPILL IN GRASSY AREA. COORDINATE THERMOSTAT SENSOR LOCATION WITH FURNITURE LAYOUT AND OWNER'S REP PRIOR TO ROUGH —IN OF BACKBOX AND WIRE. NEW AIRHANDLER. (SEE DETAIL) VOLUME DAMPER IN EACH BRANCH SUPPLY & RETURN DUCT (TYPICAL THROUGHOUT), LOCATE ABOVE LAY --IN CEILING ONLY. DAMPER TO BE ACCESSIBLE AFTER CONSTRUCTION IS COMPLETED. ROUTE REFRIGERANT PIPING THROUGH ATTIC & DOWN AT EXTERIOR WALL. SEAL WALL PENETRATION WEATHERTIGHT. PROVIDE A METAL COVER AROUND THE REFRIGERANT LINE SET. PLACE CONDENSERS ON EXISTING PAD AND SECURE PER DETAIL, (D EXISTING CONDENSERS, SERVICE AND CLEAN COILS. Z� STEPANEK—L ANDASSOCIATES 1)2257 TWELVE OAKS WAY, SUITE 103 EY CHAPEL, FL 33544 PH (813) 991-1248 REGISTRY # 8397 21 —1 43_,) 0 0 W co n co �b -i N LL Z M _j z 0. LL E _j co 0 Job Nuffiw Z� �%j I I I I l#ll' ,,%%% ON D " � c N V� No 56189 STATE 0- t�j 0 R ks, r" — —I-- I MATTHEW D. LEWIS, P.E. FL LIC#56189 PLUMBING SPECIFICATIONS SCOPE: THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE THE DRAWINGS AND SPECIFICATIONS BEFORE SUBMITTING A PROPOSAL. ALL WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODES SEVENTH EDITION (2020), WITH AMENDMENTS, AND LOCAL CODES AND ORDINANCES. INSTALLATION SHALL COMPLY WITH THE CODE REFERENCED STANDARDS SET BY NFPA, ASHRAE, ASPE, SMACNA, NEC AND UL. THE SYSTEMS, EQUIPMENT, DEVICES AND ACCESSORIES SHALL BE INSTALLED, FINISHED, TESTED AND ADJUSTED FOR CONTINUOUS AND PROPER OPERATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK FITTING IN PLACE AND SHALL COORDINATE WITH OTHER TRADES TO AVOID INTERFERENCE WITH THEIR WORK. THE INFORMATION GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED, BUT ITS EXTREME ACCURACY IS NOT GUARANTEED. THE DRAWINGS ARE DIAGRAMMATIC, INTENDED TO SHOW GENERAL ARRANGEMENT, CAPACITY AND LOCATION OF VARIOUS COMPONENTS, EQUIPMENTS, AND DEVICES. IF WORK IS REQUIRED IN A MANNER TO MAKE IT IMPOSSIBLE TO PRODUCE FIRST CLASS WORK, OR SHOULD DISCREPANCIES APPEAR AMOUNG THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND THE MANUFACTURER'S RECOMMENDATIONS,THE CONTRACTOR SHALL REQUEST INTERPRETATION BEFORE PROCEDING WITH WORK. CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION WHETHER OR NOT SPECIFIED IN THE DOCUMENTS. REQUIRED COORDINATION: ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS AND PIPING (INCLUDING DIVIDED DUCTS) AND TRANSITIONS AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. CONSTRUCTION PLANS: IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. REQUIRED ACCESS: CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT AND DEVICES THAT REQUIRE REPLACEMENT, SERVICING, ADJUSTING OR MAINTENANCE SHALL BE LOCATED TO ALLOW EASY ACCESS AND SPACE FOR REMOVAL OF INTERNAL ASSMBLIES, IF REQUIRED. CONTRACTOR SHALL PROVIDE ACCESS PANELS WHERE REQUIRED TO ALLOW ACCESS, EVEN IF NOT INDICATED ON THE DRAWINGS AT NO ADDITIONAL COST TO OWNER. WIND RESISTANCE: ALL EQUIPMENT, APPLIANCE AND SUPPORTS LOCATED EXTERIOR OF THE FACILITY SHALL BE INSTALLED TO RESIST WIND LOADS AS DETAILED IN THE BUILDING CODE. CUTTING AND PATCHING: ALL OPENINGS AROUND DUCT OR PIPE PENETRATIONS THROUGH SMOKE OR FIRE RATED FLOORS, CEILINGS OR WALLS SHALL BE SEALED AIRTIGHT WITH MATERIALS HAVING A RATING EQUAL TO THE MATERIAL OF THE WALL, CEILING OR FLOOR PENETRATED. EQUIPMENT TAGS: ALL EQUIPMENT WILL HAVE A PERMANENTLY FIXED TAG CORRESPONDING TO THE EQUIPMENT TAG ON THE ENGINEER'S DRAWINGS. FIRESTOPPING: UL APPROVED MATERIALS AND METHODS SHALL PROTECT THE PENETRATIONS OF FIRE AND/OR SMOKE RATED WALLS, CEILINGS OR FLOORS. THE RATING OF THE FIRESTOPPING SHALL EQUAL THE RATING OF THE RATED ASSEMBLY. ALL INSULATION SHALL HAVE COMPOSITE FIRE AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE ASTM E-84, NFPA-225, UL-723 NOT EXCEEDING: FLAME SPREAD 25 SMOKE DEVELOPED 50 FUEL DISTRIBUTED 50 ACCESSORIES SUCH AS ADHESIVE, MASTIC, CEMENTS AND TAPES SHALL HAVE THE SAME COMPONENT RATING AS LISTED ABOVE. SERVICE AND PERMITS: CONTRACTOR SHALL MAKE ALL ARRANGEMENTS WITH UTILITY COMPANIES FOR SERVICE AND CONNECTIONS AND SHALL PAY FOR PERMITS. SHOP DRAWINGS: EACH TRADE SHALL PREPARE AND SUBMIT SHOP DRAWINGS IN ACCORDANCE WITH PROCEDURES OUTLINED IN DIVISION 1. RESPONSIBILITY FOR ERRORS OR OMISSIONS IN THE SUBMITTALS SHALL NOT BE RELIEVED BY THE ARCHITECT'S OR ENGINEER'S REVIEW. ENGINEER'S PROCESSING WILL NOT CONSTITUTE A COMPLETE CHECK BUT WILL INDICATE ONLY THAT A GENERAL METHOD OF CONSTRUCTION AND DETAILING IS SATISFACTORY. AT A MINIMUM SUBMITTALS SHALL INCLUDE FIXTURES, VALVES, PIPING, INSULATION AND ACCESSORIES. START-UP: CONTRACTOR SHALL STARTUP ALL EQUIPMENT AND FOLLOW THE MANUFACTURER'S START-UP PROCEDURES. OPERATING AND MAINTENANCE DATA: SUBMIT THREE COPIES OF MANUFACTURER'S OPERATING AND MAINTENANCE INSTRUCTIONS AND SPARE PARTS LIST FOR EACH PIECE OF EQUIPMENT. SUPPLEMENTARY SUPPORTS: CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL EQUIPMENT AND MATERIALS, IN ORDER TO PROVIDE A "VIBRATION- FREE" RIGID INSTALLATION. DIELECTRIC UNIONS: PROVIDE DIELECTRIC UNIONS OR FLANGES AT CONNECTIONS OR CONTACT BETWEEN PIPES OF DISSIMILAR METALS. MEDICAL GAS Z VACUUM PIPING: COMPRESSED AIR PIPING SHALL BE OIL -FREE TYPE-L COPPER IN ACCORDANCE WITH ASTM-B75 / ASTM-B819, AND IN ACCORDANCE WITH NFPA-99 (2015 ED.). COMPRESSED AIR PIPING SHALL BE WRAPPED WITH SHURTAPE BRAND TAPE WHERE IN CONTACT WITH SOIL. VACUUM PIPING SHALL BE SCHEDULE 40-PVC WITH SOLVENT FITTINGS. WATER PIPING: WATER PIPING SHALL BE CPVC TUBING. TUBING, FITTINGS AND CEMENT SHALL MEET ASTM D-2846, 100 PSI 0 180*17 CONTINUOUS RATING. CPVC TUBING AND FITTINGS SHALL MEET 25/50 FLAME SPREAD/SMOKE DEVELOPED REQUIREMENTS FOR PLENUMS. CONTRACTOR SHALL INSTALL CPVC IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONTRACTOR SHALL PROVIDE FOR EXPANSION AND CONTRACTION OF TUBING. TUBING SHALL BE SLEEVED AT PENETRATION OF CONCRETE SLABS OR WALLS. CPVC TUBING SHALL BE BFGOODRICH FLOWGUARD GOLD OR APPROVED EQUAL. INSTALL PIPE SUPPORTS AT 3-FOOT INTERVALS FOR SIZES 1" OR SMALLER; INSTALL PIPE SUPPORTS AT 4-FOOT INTERVALS FOR 1-1/4" AND LARGER. WATER HAMMER ARRESTORS: INSTALL WATER HAMMER ARRESTERS AT EACH HOT AND COLD FIXTURE SUPPLY. EXPOSED PIPING: EXPOSED PIPING SHALL BE POLISHED CHROMIUM ON EITHER BRASS OR BRONZE. PROVIDE ADA INSULATED WATER AND WASTE LINE COVERINGS FOR WALL HUNG SINKS AND LAVATORIES. VALVES: ALL VALVES SHALL HAVE A MINIMUM OF 125 PSIG WORKING PRESSURE. VALVES AND COCKS MAY NOT BE INDICATED IN EVERY INSTANCE ON THE DRAWINGS, BUT WHETHER OR NOT SHOWN, ALL VALVES, COCKS AND CHECK VALVES NECESSARY FOR THE PROPER OPERATION OF THE SYSTEM SHALL BE FURNISHED AND INSTALLED. INSTALL ISOLATION/SHUT-OFF VALVES AT ALL MAIN RISERS, AND MAIN BRANCH TAKEOFFS. INSTALL ISOLATION/SHUT-OFF VALVES ON EACH INLET AND OUTLET OF EACH PIECE OF EQUIPMENT. PROVIDE A FLANGE OR UNION BETWEEN THE VALVE AND THE EQUIPMENT TO PERMIT DISCONNECTION, REMOVAL AND SERVICE. STERILIZATION OF DOMESTIC WATER SYSTEM: THE ENTIRE DOMESTIC WATER DISTRIBUTION SYSTEM SHALL BE THOROUGHLY STERILIZED AS REQUIRED BY THE HEALTH AUTHORITY OR WATER PURVEYOR HAVING JURISDICTION, OR IN THE ABSENCE OF A PRESCRIBED METHOD, THE PROCEDURE DESCRIBED IN EITHER AWWA C651 OR AWWA C652, OR AS DESCRIBED IN SECTION 610 FBC-P. VENTING: THE STACKS SHALL BE EXTENDED THROUGH ROOF OF BUILDING TO POINTS NOT LESS THAN 12" ABOVE ROOF. VENTS SHALL BE OFFSET AS REQUIRED TO PENETRATE ROOFS AT LEAST 3 FEET FROM THE RIDGE OR EDGE OF BUILDING AND 10 FEET FROM ANY FRESH AIR INTAKE OR OPERABLE WINDOW OR DOOR. SANITARY, WASTE, AND VENT PIPING: ALL BURIED AND UNBURIED PIPING AND FITTINGS SHALL BE SCHEDULE 40 PVC-DWV. (SOLID CORE) SLOPE OF SANITARY OR DRAINAGE PIPING 2-1/2" AND SMALLER SHALL BE A MINIMUM OF 1/4" PER FOOT; PIPING 3" AND LARGER SHALL BE SLOPED A MINIMUM OF 1/8" PER FOOT. CLEANOUTS WILL BE LOCATED NOT MORE THAN 100 FEET APART AND AT EACH CHANGE OF DIRECTION GREATER THAN 45* ALONG THE HORIZONTAL DRAIN. CLEANOUTS SHALL BE INSTALLED AT BASE OF EACH STACK. CONCEALED CLEANOUTS SHALL HAVE CAST BRASS CHROMIUM PLATED FLAT ACCESS COVER PLATE. FLOOR DRAINS/SINKS: FLOOR DRAINS SHALL BE CAST IRON AND ADJUSTABLE TO ACCOMMODATE THE FINISHED FLOOR. FLOOR SINKS SHALL HAVE AN ACID -RESISTANT ENAMELED INTERIOR. STRAINERS SHALL BE PROVIDED WITH BARRIER -TYPE TRAP SEAL PROTECTION (ASSE 1072) AND FLASHING FLANGE OR CLAMP, UNLESS OTHERWISE INDICATED. DOMESTIC WATER HEATERS (ELECTRIC): WATER HEATER SHALL BE CERTIFIED BY THE NATIONAL SANITATION FOUNDATION & UL-LISTED. UNITS SHALL BE EQUIPPED WITH CODE -APPROVED TEMPERATURE AND PRESSURE RELIEF VALVES. TANKS SHALL BE GLASS -LINED AND SHALL HAVE MANUFACTURIER'S STANDARD FIVE-YEAR WARRANTY. PLUMBING FIXTURES AND TRIM: PLUMBING FIXTURES SHALL BE FURNISHED AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER WITH PROPER CONNECTIONS TO SUPPLY AND DRAINAGE PIPING. ALL FIXTURES SHALL BE FREE OF FLAWS AND DEFECTS OF ANY SORT IN MATERIAL AND WORKMANSHIP AND SHALL OPERATE PERFECTLY WHEN INSTALLED IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS. CONTRACTOR SHALL PROVIDE ROUGH -IN, AND SHALL CONNECT ALL FIXTURES TO THE PLUMBING SYSTEMS. ALL FIXTURES TO BE PROVIDED WITH CHROME -PLATED SUPPLIES AND STOPS. PROVIDE 17 GAUGE CHROME -PLATED BRASS TRAPS FOR ALL FIXTURES WITHOUT INTEGRAL TRAPS. PROVIDE CONCEALED ARM CARRIERS AND SUPPORTS FOR ALL FIXTURES REQUIRING SAME. PIPE INSULATION: INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. SEAL ALL JOINTS, BREAKS, TEARS AND PENETRATIONS WITH FIRE RETARDENT, VAPOR BARRIER MASTIC. COVER VALVES, FITTINGS AND SIMILAR ITEMS IN EACH PIPING SYSTEMS. INSULATE ALL DOMESTIC HOT WATER AND INTERIOR STORM PIPE WITH 1" THICK FIBERGLASS SECTIONAL PIPE COVERING WITH CANVAS JACKET OR ARMAFLEX AP (ASTM E-84). PIPE INSULATION: INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. SEAL ALL JOINTS, BREAKS, TEARS AND PENETRATIONS WITH FIRE RETARDENT, VAPOR BARRIER MASTIC. COVER VALVES, FITTINGS AND SIMILAR ITEMS IN EACH PIPING SYSTEMS. INSULATE ALL DOMESTIC HOT WATER AND ALL PIPING EXPOSED IN RESIDENCE UTILITY ROOMS WITH 1" THICK PLENUM RATED ARMAFLEX AP SECTIONAL PIPE COVERING (ASTM E-84). TESTING: TEST ALL WASTE AND VENT PIPING FOR A PERIOD OF NOT LESS THAN 8 HOURS BY CAPPING OR PLUGGING. ALL JOINTS TO A LEVEL OF THE HIGHEST FIXTURE OR FITTINGS. FILLING THE SYSTEM WITH WATER, AND OBSERVING FOR LEAKS. TEST WATER PIPING AT 100 PSIG FOR A PERIOD OF 8 HOURS, OBSERVING FOR ANY VISIBLE LEAKS. TEST PIPING AGAIN WITH FIXTURES INSTALLED. REPAIR ANY LEAKS FOUND BY REMAKING JOINT. DO NOT USE CAULKING OR SIMILAR METHODS TO CORRECT LEAKS. UPON REPAIRING ANY LEAKS FOUND. AGAIN TEST THAT PORTION OF THE SYSTEM AS DESCRIBED ABOVE. EQUIPMENT FURNISHED BY OTHERS: WHERE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL MAKE ALL PIPING CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS. THIS WORK SHALL INCLUDE FURNISHING AND INSTALLATION OF ALL WATER AND DRAIN PIPING. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH RECOMMENDATIONS OF EQUIPMENT MANUFACTURER. GUARANTEE: THE ONE-YEAR GUARANTEE PERIOD SHALL NOT START UNTIL THE PROJECT IS FULLY COMPLETED AND THE CONTRACTOR HAS RECEIVED THE FINAL PAYMENT AND CERTIFICATION OF COMPLETION. ALL EQUIPMENT AND ALL WORK SHALL BE FULLY GUARANTEED, PARTS AND LABOR, FOR ONE YEAR FROM THE DATE OF THE CERTIFICATE OF COMPLETION. REPAIRS MADE DURING THIS PEROID MUST BE FULLY GUARANTEED FOR AN ADDITIONAL ONE YEAR PERIOD FROM THE DATE OF REPAIRS. IN ADDITION, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDING, AND ITS CONTENTS OR OTHER EQUIPMENT, CAUSED BY DEFECTS OR IMPROPER INSTALLATION OF EQUIPMENT OR MATERIAL INSTALLED. SUBSTITUTIONS: CONTRACTOR SHALL PAY FOR ANY AND ALL ADDED COSTS ASSOCIATED WITH ANY SUBSTITUTION, INCLUDING SUBSTITUTIONS THAT REQUIRE CHANGES TO THE OTHER BUILDING COMPONENTS, SUCH AS ELECTRICAL, STRUCTURAL REINFORCING, CEILINGS, WALLS, ROOFS, ETC. THIS WILL INCLUDE ANY ENGINEERING/ARCHITECTURAL RE -DESIGN COSTS AS A RESULT OF SAID SUBSTITUTION. THESE COSTS SHALL NOT BE BORNE BY THE OWNER, ARCHITECT, NOR ENGINEER, REGARDLESS OF ACCEPTABILITY OF SUBSTITUTION. ENGINEER RESERVES THE RIGHT TO ACCEPT OR DENY ANY SUBSTITUTION THAT HE DOES NOT DEEM TO BE EQUIVALENT, AND CONTRACTOR SHALL PROVIDE SPECIFIED OR EQUIVALENT MATERIALS/EQUIPMENT AT NO ADDITIONAL COST TO OWNER, SHOULD A SUBSTITUTION BE DENIED. FIXTURE & CONNECTION SCHEDULE BRANCH SIZE I FIXTURE TAG MANUFACTURER/MODEL REMARKS DRAINAGE WATE WASTE VENT COLD HOT WATER CLOSET WC-11 3" 2" 1/2" AMERICAN STANDARD CADET #2467.016 PRESSURE -ASSISTED TANK, VITREOUS CHINA, ELONGATED BOWL, SIPHON JET, FLOOR (HANDICAPPED) SEAT: BEMIS # 1655SSCT MOUNTED. FLUSH HANDLE ON WIDE SIDE OF STALL. 16-1/2" BOWL RIM HEIGHT, & FULLY GLAZED 2-1/8" TRAPWAY. SOLID WHITE PLASTIC SEAT WITH OPEN FRONT & SELF-SUSTAINING CHECK HINGES. ALSO, PROVIDE 3/8" SUPPLY AND STOP, CLOSET FLANGE, WAX SEAL RING, NUTS, BOLTS AND WASHERS AS REQUIRED. LAVATORY LAV- 1 2" 2" 1/2" 1/2" AMERICAN STANDARD LUCERNE #0355.012 LAVATORY: 20"x`18", VITREOUS CHINA, WITH FAUCET LEDGE AND INTEGRAL (ADA) DELTA SINGLE LEVER FAUCET #523LF-HGMHDF OVERFLOW. PROVIDE ARM CHAIR FLOOR CARRIER. SINGLE LEVER FAUCET WITH 4" CENTERS, O.5-GPM AERATOR, & GRID DRAIN ASSEMBLY. PROVIDE MIXING VALVE: LAWLER # TMM-1070 ASSE 1070 LISTED MIXING VALVE SET TO 109*F, TAILPIECE, P-TRAP, SUPPLY CARRIER: ZURN #Z1231 & STOPS. INSULATE EXPOSED PIPING WITH TRUEBRO LAV GUARD KIT. DRINKING FOUNTAIN EWC-1 2" 2 1/2" -- ELKAY # EZSTL8C DRINKING FOUNTAIN: ELECTRIC WATER COOLER, 2-STATION, (HI-LO = ADA) CARRIER: ZURN #Z1225 STAINLESS STEEL BASINS, WITH MANIFOLD WATER/SANITARY CONNECTIONS, FLOOR CARRIER. 120-V/1-PH. DISCONNECT BY ELECTRICIAN MOP SINK MS-1 2" 2" 1/2" 1/2" FIAT # MSB 2424 MOP SINK: MOLDED PLASTIC, 10" LIP EDGE, 2" DRAIN & BASKET STRAINER. ACCESSORIES: FIAT #830AA, 832AA & 889CC PROVIDE WALL MOUNTED FAUCET WITH BRACKET ARM & PAIL HOOK, MOP HANGER, HOSE AND HOSE BRACKET. RECIRC PUMP RP-1 1/2" TACO 003 HOT WATER RECIRCULATION PUMP. 115 V, 0.43 AMP, 1/40 HP, 1/2" CONNECTIONS, 5 FT HEAD. PROVIDE BALANCE VALVE, AQUASTAT & 7-DAY PROGRAMMABLE TIMER. ICE BOX IB-1 -- 1/2" -- GUY GRAY # BIM875 ICE MAKER BOX: GALVANIZED STEEL, 18 GA. FACEPLATE, 1/4-TURN STOP, COMBINATION MIP OR SWEAT CONNECTION. PROVIDE WATER HAMMER ARRESTOR. PROVIDE ASSE 1022 CHECK VALVE AFTER STOP FOR VISUAL INDICATION FOR FAILURE. EXAM SINK ES-1 2" 2" 1/2" 1/2" DAYTON # D11515 COUNTERTOP MOUNT, 12"XlO"X5"BOWL, STAINLESS STEEL. PROVIDE STOPS, ZURN # Z812B4-3F SUPPLIES, TRAP, ETC., TO MAKE A COMPLETE INSTALLATION. FAUCET: DUAL WRIST BLADE HANDLES, DECK MOUNT GOOSENECK FAUCET WITH GRID STRAINER, & 0.5GPM AERATOR. HAND SINK S-1 2- 2" 1/2" 1/2" JUST MFG # WHL-14-S WALL MOUNT, ROUND BOWL, STAINLESS STEEL. PROVIDE STOPS, SUPPLIES, TRAP, ETC., TO MAKE A COMPLETE INSTALLATION. FAUCET: SENSOR OPERATED, 120-VOLT WALL PLUG. SINK LS-1 2" 2" 1/2" 1/2" DAYTON ELITE # D12521 COUNTER MOUNT, 1-COMPARTMENT STAINLESS STEEL SINK, COATED UNDERSIDE FAUCET: ZURN #Z812C4-3F SELF -RIMMING, 6" DEEP, 2" DRAIN & BASKET STRAINER, WITH FAUCET HOLES ON GUARDIAN # G1200 EYEWASH 4 IN. CENTERS. FAUCET: GOOSENECK FAUCET WITH 4" WRIST BLADES HANDLES. PROVIDE STOPS, SUPPLIES, TRAP, ETC., TO MAKE A COMPLETE INSTALLATION. MIXING VALVE: LAWLER # 911E/F PROVIDE UNDER COUNTER ASSE 1071 MIXING VALVE SET TO 95*F. PROVIDE FAUCET MOUNTED EYEWASH WITH SINGLE MOTION CONTROL. BREAK SINK BS-1 2" 2" 1/2" 1/2" DAYTON ELITE # D12521 SINK: 25"X21"; 1-COMPARTMENT STAINLESS STEEL, COATED UNDERSIDE FAUCET: ZURN # Z87lC4-XL SELF -RIMMING, 2" DRAIN & BASKET STRAINER, WITH TWO FAUCET HOLE. 8"GOOSENECK FAUCET, 4;;WRISTBLADE HANDLE. PROVIDE STOPS, SUPPLIES, TRAP, ETC., TO MAKE A COMPLETE INSTALLATION. FLOOR DRAIN FD-1 3' 2" �7 '7 -7 77 v � 7, 7 T, 77 v ZURN # Z415E 6URA-COATED CAST IRON-66DY, '6"D'lAa�rER'13_R6`NZ_E -AD-JU-STA-BL-E-ST-RAI-NE-R-WI-TH� ZURN # Z1072 FUNNEL. PROVIDE 4" DEEP TRAP AND TRAP GUARD (ASSE 1072 CERTIFIED). WALL CLEANOUT WCO SEE ZURN 0 Z1468 WALL CLEANOUT - ROUND STAINLESS STEEL WALL ACCESS COVER PLANI WITH SECURING SCREW AND BRONZE RAISED HEX HEAD PLUG. I PLUMBING LEGEND DESCRIPTION ABBREV. SYMBOL SANITARY PIPING SAN VENT PIPING V ------------------ DOMESTIC COLD WATER CW DOMESTIC HOT WATER HW COMPRESSED AIR PIPING CA ---CA----- VACUUM PIPING VAC ----VAC----- FILTERED WATER PIPING FW — - -FW- NITROUS PIPING N _N OXYGEN PIPING Ox Ox BALL/ISOLATION VALVE BV __d)l_ DUAL -CHECK BACKFLOW N PREVENTER GRADE CLEAN OUT COTG COTG WALL CLEAN OUT WCO Wco 1! 0 FLOOR CLEAN OUT FCO FCO 0— PIPE TURNING UP 0— - PIPE TURNING DOWN C CAPPED PIPING Er— - — TYPICAL ITEM TYP CONNECTION BETWEEN NEW & EXISTING EXISTING (E) NEW (N) I BALANCE VALVE BV NOTE ON EXISTING UTILITIES: CONTRACTOR SHALL FIELD VERIFY LOCATIONS & INVERTS OF ALL EXISTING UTILITY MAINS INSIDE BUILDING (I.E. SEWER, GAS, DOMESTIC WATER, ETC.) PRIOR TO ANY DEMOLITION OR CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY FURTHER. ** CCTV VIDEO CAMERA INVESTIGATION REQUIRED BY PLUMBER (PRIOR TO ANY WORK) TO VERIFY INVERT ADEQUATE AT MOST REMOTE AREA OF NEW SANITARY UNDERGROUND CONNECTION. NOTIFY ENGINEER OF RESULTS OF CAMERA WORK. IALL ROOF DRAINAGE IS EXISTING TO REMAIN. I NOTE TO CONTRACTOR ON EXISTING CONDITIONS: CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND SURVEY ALL EXISTING CONDITIONS AND EQUIPMENT PRIOR TO SUBMITTING BID FOR WORK REQUIRED BY THESE DOCUMENTS. THIS INCLUDES ABOVE THE CEILING AND ON TOP OF THE ROOF. 2. CONTRACTOR SHALL REFER TO AND READ THROUGH ALL OF THE "CONTRACTOR'S SCOPE OF WORK" AS DEFINED IN THE BID SPECIFICATIONS AND DOCUMENTS AS PART OF THE BID PROCESS. 3. IF AT ANY TIME,- THERE IS DISCREPANCY BETWEEN THE PLANS & SPECS, OR CONFUSION /CONCERN OVER REQUIRED WORK, CONTRACTOR SHALL IMMEDIATELY NOTIFY ARCHITECT, ENGINEER, &/OR OWNER AND GET DIRECTION BEFORE PROCEEDING WITH WORK IN QUESTION. 4. FOR ALL NEW ROOF PENETRATIONS, CONTRACTOR SHALL INCLUDE IN HIS BID THE COST TO HIRE THE ROOFING FIRM HOLDING THE WARRANTY TO PROVIDE ROOF PENETRATIONS. 5. FOR ALL EXISTING EQUIPMENT TO BE RE -LOCATED &/OR RE -USED, CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION, SAFE STORAGE, & RE -CONNECTION OF SAID EQUIPMENT COMPLETELY. 6. FOR ALL EXISTING EQUIPMENT TO BE DEMOLISHED (I.E. DEMO) CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION, REMOVAL, & DISPOSAL OFF -SITE PER CODE, OF SAID EQUIPMENT COMPLETELY. STEPANEK-L ANDASSOCIATES k9r,-7 TWrl Vr OAKS WAY, SUITE 103 WESLEY CHAPEL, FL 33544 PH (813) 991-1248 REGISTRY # 8397 21-143 6 c: (0 Q) 00 Z M_j Z C. LL E co C.0 �_ (0 c, 00 0 CO 0) 0 Job Number �_-\N D No 56189 STATE A R ON A I, I I I I i [a MATTHEW D. LEWIS, P.E. FL LIC#56189 hwA Date 09-03-21 FAI FROM BUILDING DISTRIBUTION WALL -SEE FLOOR PLANS SUPPLY PIPE -SEE PLUMB BLOCKING BETWEEN STUDS PIPE TO EQUIP. FIXTURE SILICON CAULK-FSE AREAS QUARTER -TURN ANGLE STOP (TYP) CHROME TRIM ELBOW W/ANCHOR FLANGE FIXTURE SHUT-OFF VALVE NOTTO SCALE Al PROVIDE A ONE PIECE SPUN ALUMINUM NJ BASE, WITH GRADULATED STEPPED PVC BOOT, AND ADJUSTABLE STAINLESS STEEL CLAMPS. ROOF MASTIC ROOF' INSULATION H 11 ROOF INSULATION ROOF.DECK ] 1 110 ROOFDECK PROVIDE SLEEVE IF ---,_ANCHOR PIPE TO ROOF DECK OR JOIST REQUIRED BY ROOF DECK WITH U-BOLT AROUND PIPE AND ANGLE IRON WELDED OR SCREWED TO ROOF DECK OR JOIST. PROVIDE TRANSITION TO 3" VENT THRU ROOF HUBLESS PIPE CONNECTORS LN -: � �k �m Z-� �-me �* �s �'� I � SCALE: NONE REFER TO PLANS FOR VTR LOCATIONS. PROVIDE MINIMUM OF 10 FT FROM ALL FRESH AIR INTAKES. PROVIDE 1" FIBERGLASS INSULATION WITH ALL -SERVICE JACKET ON VENT PIPE INSIDE OF BUILDING WITHIN 6 FT OF VTR LOCATION. COORDINATE AND VERIFY FLASHING AND COUNTER FLASHING WITH ROOFING CONTRACTOR. VACUUM SWITCH AND GAUGE MAINLINE ---/ ISOLATION (SOURCE SHUTOFF) VALVE \ FLEX. CONNECTION ISOLATION VALVE (TYPICAL) RECEIVER 1-1/4" DRAIN ------ TO FLOOR DRAIN UNION (TYPICAL) CHECK VALVE TYPICAL) 's� d VAC.PUMP (1 OF 2) VACUUM PUMP DETAIL NOT TO SCALE MAY EXTEND AS A WASTE OR VENT. REFER TO PLANS.--\ CHROME WALLCOVER & SCREW � BALANCE OF PIPING SAME AS CLEANOUT TO GRADE - �-2" DISCHARGE ABOVE ROOF MIN. 10-FT ABOVE GRADE WITH GOOSENECK & STAINLESS STEEL SCREEN ROUTE 2" DRAIN !//"--TO FLOOR DRAIN WALL PLUGGED TEE W/CLEANOUT FLOOR LINE 1/8" BEND WALL CLEANOUT NOT TO SCALE BRASS FUNNEL (CUT OPENING IN CABIN��R�Y BASE FOR FUNNEL) CAST BASS GRATE TILE, 1/4" SLOPE MIN. LATICRETE 9235 WATERPROOF MEMBRANE EPDXY GROUT DRAIN W/ COLLAR FLOOR TRAP GUARD INSERT (ASSE 1072 CERTIFIED) NOTE: FUNNEL ALLOWS FLOOR TO DRAIN INTO STRAINER FLOOR DRAIN WITH TRAP GUARD DETAIL SCALE: NONE STEPANEK-L % ANDASSOCIATES - ir2257 TWELVE OAKS WAY, SUITE 103 WESLEY CHAPEL, FL 33544 PH (813) 991-1248 REGISTRY # 8397 21 —1 43�') 4.1 co 00 In (00 m 0 cy) (0 c\l Z z CL LL :D E o cu CD co _j — 00 — (0 U) 00 >1 >1 N 10 C) -0 co (D M c: 4-a -W mxvlw A zns' %%0%M I No 56189 '8( -33 STATE 0F 0 R 1/0 N A 11116111 40','fl Shoot No. ��K MATTHEW D. LEWIS, P.E. FL LIC#56189 hmm Date 09-0" Ac_ I Ac 2 L21� AC_ 3 F, 51 a 190% "0 1201 Fm ELEC 1201 1201 FE \\—EXISTING HOSE E7�EC t 4 -0 Ed— STORA!�j BIBB TO REMAIN RN IT > DOCTOR 11:21 UTILITY ELEC PE 5REAK ROO D 1 17 Ll� E -LA DOCTOR .XA FE JELE _u El — TOILET F5 2] [2 F2] 'IT 7 71- BULKHEAD EX STING WATER HEATER IN ATTIC TO REMAIN OFFICE 2EE-1 CE MANAG� F! A] FAMILY"/// F-71 E X A F7] E 108 F 51 71.77= PEDI BULKHEAD Ex —AN ABOVE 202 -A J: ji, r2] -c- T--- -Ij T j _j Ell Lt a 3 'u J I! I NATER D15—j BOTTLE ALL EXISTING PLUMBING FIXTURES NOT 121 OTHERWISE NOTED ARE TO BE F5 DEMOLISHED. CAP CW/HW/VENT BACK FAM I LY LLJ AT MAIN. CAP SANITARY UNDERGROUND. �77__ 7ULKPEAID 7 A13OVE F] 11-A L11 11, "'A L 14 F2�2 2] iFANILY E7 E F2 [2] L22 EXA 11K] LL J, LIJ _j ADMIN MED QEf —Ir--E- TOILET ID-OCTO EXArl D7 [2] [2�2 EXISTING WATER HEATER Ej LOCKABIE IN ATTIC TO REMAIN Ft A NEC) F21 DMIN OEFIG POCKETi [2] DOOR --I PEDI >) 'I�XA Copy BULKHEAD RECEPT/ ApInIN AE30VE L [2] L L_J TI_ EXISTING RESTROOM AND SINK TO REMAIN T a] E31 0 ILY OD FAMILY FAM FAMIJ Y EXAM EXAM DRAV4 V4AITING EXIST El jOILET `F17] -E, I- L12 EXISTING HOSE EXISTING HOSE 17 N �BIBB TO -REMAIN,, BIBB TO REMAI 77 if I TTT7=1'' 11 '1`111Z1441 rZZZZ./V�_Z.Z.1 - — — — — — — — — — — — — — — — — — — -- Ej DEMOLITION FLOOR PLAN SCALE: NONE a) 00 Lo !E `0 ' 0, 2 _j LL a) z m i Z CL U. E OD 0 - 04 - 01D 6 (0 4) (3) 0 L___j E51 .. . .................. . . ....... K x X, xxxx PEDI [171 :1 ffXAN DOOR KIDS X E16 PLAY.ARF-A [:2] X Ell Job Numbw 2 [:2] PEDIATRIC PEDI NAITING �--g E VITALS EXAM \N D Y\ No 56189 _'3 0) IF /Jiv Z� , . STATE 0 A, A OR STEPANEK- L N A ANDASSOCIATES 41111111111 1 � 11 2257 TWELVE OAKS WAY, SUITE 103 Sh"t No. WESLEY CHAPEL, FL 33544 (813) 991-1248 REGISTRY # 8397 21-143 P3 MATTHEW D. LEWIS, P.E. FL LIC#56189 '1' 1 T T_ ILL TIT fINK STOR 11 1 ES-1 FD 1 MECH Sl \lK TRIMMER 1-1 LAB/ NEW BREAK RP-1 STERILIZATION ROOM 1 (E) WH CORR C CORR D FTTO I BS-1 113-1 NEW STOR 2 EXIST ELEC OPERATORY 4 PROVIDERS I\wc-1 NEW OPERATORY 3 ADA LAV-1 IE w c i STAFF COMMUNITY PANO STOR 3 SERVICE L NEW S-1 F -loi-I PRIVATE COR:� A OPERATORY1 ADA PATIENTS i 1-17— SINK LAV-1 IT + (F)H13 (E)4"COTG c, ADMIN. ENTRY LOBBY DENTAL WAITING (E)4"COTG NEW BREAK2 FAMILY EXAM 4 FAMILY EXAM 5 FAMILY EXAM 6 =1 FAMILY EXAM 7 co 0 CO 0 _j < LL Z M z a LL D E 0 _j T co 0 0� ) PEDIATRIC �_' I I FAMILY IN I I HH-1 V-f PEDIATRIC T I SCALE EXAM 3 EXAM 9 ES-1 CORRIDOR E CORRIDOR N CORRIDOR P ES-1 KI DS (E)WC EXIST PLAY AREA EXISTING STOR PEDIATRIC TOILET 1 EXAM 1 FAMILY LAV- (E LAV (E)SINK PEDIATRIC CORR M EXAM 8 EXAM 2 r EXPANDED EXISTING ADA JILY rrlr7i - — -- — -- — -- TOILET 6 FAMILY PEDIATRIC WAITING WAITING wc-1 E S -�l EXISTING ES-1 ES-1 VITALS IT Job Number _'_(E) H B (E)HB F-) A rr) Tr' fl� (F) A "rnTr, RE -CONNECT HOSE BIBB (TYPICAL ALL) EXISTING WATER METER T OM L I Al rREMOTE FROM BUILDING (TYPICAL) PLUMBING FLOOR PLAN SCALE: 3/16" = l'-O" STEPANEK—L ANDASSOCIATES )2257 TWELVE OAKS WAY, SUITE 103 WESLEY CHAPEL, FL 33544 PH (813) 991-1248 �REGIST�RY# 8397 21 —1 4�) Z� zn� 11-14 ot, E 1� No 56189 S TA J'E 011 0 P, MATTHEW D. LEWIS, P.E. FL LIC#56189 ROUTE J"FW UP AT --\\ STERLIIZER WITH DUAL —CHECK VALVE ROUTE 1/2"COMPRESSED AIR LINE UNDE�RGROUND FROM AIR COMPRESSOR ROUTE 2"VACUUM--\\ LINE UNDERGROUND FROM VACUUM ev oe� 3/4"CW FROM WATER SHUTOFF VALVE MANIFOLD AND WATER FILTER I`IAi ROUTE 112"COM PRESSED AIR, 5/8"VACUUM. AND 1/2"FW LINES UP AT DE NTAL CHAIR WITH SHUTOFFS (TYP-4) "00i- '0000� "p- TA� C., / N"A c' 6N A� MEDICAL OAS RISERS SCALE: NONE 1P 112 "Fw 1 .1 112 NT A� hA�jj ROUTE 1/2" COM PRESSED AIR, 5/8"VACUUM, AND 1/2"FW LINES UP AT CABINETRY WITH SHUTOFFS (TYR — 4) �%N AN PLUMBING KEYED NOTES ON PLAN: Al INSTALL AIR COMPRESSOR (PROVIDED BY OTHERS), ROUTE CA PIPING UNDERGROUND. QINSTALL VACUUM AND SEPARATOR (PROVIDED BY OTHERS). ROUTE VAC PIPING UNDERGROUND. QROUTE 1/2"CA/VAC/FW UP TO REAR CABINET PER DETAIL FOR REAR CABINET PIPING DETAIL. ROUTE 1/2"CA/VAC/FW UP TO DENTAL CHAIR PER DETAIL FOR UTILITY CENTER PIPING DETAIL. Q ROUTE 1/2"CA UP IN WALL PER TYPICAL AIR OUTLET DETAIL. Q INSTALL 1/2"CA/VAC/FW UP IN WALL PER STERILIZATION CABINET PIPING DETAIL. PIPING TO DENTAL EQUIPMENT TO BE UNDERGROUND. Q ROUTE 3/4"CW MAIN FOR DENTAL SUITE TO WATER FILTER AND WATER CONTROL VALVE (FILTER & VALVE MECH STER'lL'lZ'A'TI0N NEW BREAK 1. LLL 3: Ll- i C4 CORR D CORR C F -1 _25- 71 MEDICAL GAS PLAN SCALE: 1/4" = V-0" IIIIIIIIIII01 IIIIII[ PROVIDERS 1 121 ] COMMUNITY c%r-ml /If-%r- 1 1:2--5 F)F:NTAI STEPANEK-L IANDASSOCIATES 2257 TWELVE OAKS WAY, SUITE 103 WESLEY CHAPEL, FL 33544 )PH (813) 991-1248 REGISTRY # 8397 21-143") 0 (0 r- 00 LO 100 o LL Z ca . Z 0-u- E c __j 00 0 V) 0 Job Nmtmw Revkions Z� 10-6-21 A 1 V-1 -1-1- _jj_j D. E N No 56189 S I AT E 0 1 'z 0" p, 111/0 N A MATTHEW D. LEWIS, P.E. FL LIC#56189 1 ___FT f 1 11 -1 IF— ---7- ,GIN (E)WH 5, Al (E)WH I pl, IVY > >6 :/Z.Qw I (E)WH AV 'c" NOTE: l�Av SEE FIXTURE SCHEDULE FOR BRANCH SIZES TO FIXTURES TOTAL WATER FIXTURE UNITS PER FBC—P TABLE E103.3(2) 77.5 WFU REDUCTION WATER ISOMETRIC RISE SCALE: NONE STEPANEK— L ANDASSOCIATES 2257 TWELVE OAKS WAY, SUITE 103 W 1 ESLEY CHAPEL, FL 33544 PH (813) 991-1248 R EGISTRY # 8397 21-143 MATTHEW D. LEWIS, P.E. FL LIC#56189 coo CO 0 m (D LL Z cc -j z a LL 0 E (D ca CD I-- co Q) co 0 _j ; N ct) (0 U) 0 10-6-21 "m \N D V\ IV No 56189 Z STATE OF 0 R, 1.1, 0 NA�- ftill"IfIll lestis Date 09-0" p5lvfl' rb, 1 SANITARY ISOMETRIC RISE SCALE: NONE lj-- Qcj�,� 3�fp 0 c 4.1 (o (00 co 0 co (o LL z cd Z a LL E cc (D _j c' 00 (D V) 0 0� ) Job Number \N D N N o 561 89 STATE 0- r) A, 0 R 0 STEPANEK-L JANDASSOCIATES )2257 TWELVE OAKS WAY, SUITE 103 %Mt No. V WESLEY CHAPEL, FL 33544 PH (813) 991-1248 REGISTRY # 8397 21-143 P7 MATTHEW D. LEWIS, P.E. FL LIC#56189 — FT -- ;I I I . 1, , 1 1.11, 11 kl'lid .1,1-:011 �' il!]'' 4� :L z .7 Q 3, 2 PVC sc, i-i # T -F IN' 0) R AIR, !)UCT FD MANIFCA,D ANf C) P � N L r:T I N C, BY BF4CO DF ��"o COPPE-x LOCA, [I0NS/;,P, F)PIVF -,AS,/[.)E AcR CCIIAPRF,-�� MIDMARK P22 27`t,x26"Wx2�' 3 2 x 2 6 ­V%�'x 2 WLIGIII: &-�PL-IED B� INSIALLED BY DETAIL - AIR COMPRESSOR REF SOUR( VA.( T R I SEF suf INS f DETAIL - AMALGAM SEPARATOR REF SOUR, 'vA' j- M -II 011AI: HEET S E PlRiV� .,A'�:v STUB W/,8 VALVE. v DRA!'N - I TO C,,,'..;NF0F BUILDIING C 1�4- WAIL /�"OD COM iOl WAILR Q F) *NOTF: SEF R, I EMPLATE LOCA,'i()NS. DETAIL - STERILIZATION CABINET PIPING REF SOUR DETAIL IREF, SOUR all u Imm Date 09-03-0 ci OD Lj) LL Z M . Z 0- ILL 0 E M (0 0 N - 00 0 C; cf) — co a) -0 0 >1 :E LL IE N 10 co co c: Job Nufftm RevWK= "t,11111111111 It, \P4 D C, No 56189 STATE OF r) A�l R STEPANEK-L ANDASSOCIATES Y1 '4 Lj 299-55-7 TWELVE OAKS WAY, SUITE 103 Sheet Nm WESLEY CHAPEL, FIL 33544 PH (813) 991 —1248 REGISTRY # 8397 21-143 P8 MATTHEW D. LEWIS, P.E. FL LIC#56189 PROJEGT NOTES E " 1. ALL WORK SMALL BE IN STRICT ACCORDANCE P41TH THE 2011 EDITION OF THE NATIONAL L ELECTRICAL CODE (N.E.0) AND ALL LOCAL CODES AND ORDNANCE5. E 2. ALL MATERIAL5 SHALL 13E NEW AND OF DOMESTIC ORIeIN AND SHALL BEAR UN0ERHRITEq;z5- G LABEL WHERE APPLICABLE. T 3. ALL WORK SMALL BE PERFORMED BY A LICENSED ELECTRJICAL GONTRACTOR IN A FIR5T-CLA55 WORKMANLIKE MANNER. THE COMPLETED SYSTEM 15 TO BE FULLY OPERABLE AND ACCEPTANCE OF TH15 SYSTEM BY THE EN65INEER/ARCHITECT MUST BE A CONDITION OF THE SU5 CONTRACT. 4. ALL HORK TO BE COORDINATED HITH OTHER TRADE-5 TO AVOID INTERFERENCE P41TH THE PROC-RE-55 OF CONSTRUCTION. A 5. CONTRACTOR TO OUARANTEE ALL MATERIALS AND HORKMAN5441P FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTAW-1E. L 6. CORRECTION OF ANY DEFECTS TO BE COMPLETED V41THOUT ADDITIONAL GHAR67E AND To INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION 144IGH MAY' HAVE BEEN DAMA6ED THEREBY. -1. ALL REaUIRED INSURANCE TO BE PROVIDED FOR PROTECTION A&AIN5T PUBLIC LIABILITY OF PROPERTY DAMA65E FOR THE DURATION OF THE WORK. 5. CONTRACTOR TO PAY FOR ALL PERMITS, FEE5, IN5PECTION5 AND TE5TIN67. cf. ELECTRICAL INSTALLATION TO MEET ALL STANDARD REGUIREMENT5 OF LOCAL POWER AND TELEPHONE GOMPANIE-5, 10. MINIMUM V41RE SIZE SHALL BE #12 AH&, EXCLUDINO CONTROL HIRIN6. UNLE55 OTHERWISE NOTED, CONDUCTOR55HALL 13E COPPER P41TH THHN/THHN INSULATION. 0ONDUCTOR5 #12 ANDSMALLER MAY BE SOLID; ALL TH05E #10 AND LAR6C-R TO BE STRANDED. 111. ALL UNDER&ROUND RACEWAYS SHALL BE &ALVANIZEH�� RI&ID STEEL CONDUIT OR SCHEDULE 40 PVG. ALL OTHER RACEWAYS TO COMPLY WITH 6OVERNIN& CODES. MINIMUM GONDUIT UNDER64ROUND SHALL BE 3/4" CONDUIT UNLE55 OTHERWISE NOTED. 12. OUTLET BOXE55HALL BE PRE55ED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HU55 IN WET OR DAMP LOGATION5, AND BE OF SPECIAL CONSTRUCTION FOR OTHER CLASSIFIED AREAS. ALL BOXE-5 SHALL BE RECESSED (FLUSH) IN HALLS OR CEILIN66 WHENEVER P05515LE. 13. DISCONNECT 5HITCHE-5 SHALL BE M.P. RATED, 6ENERAL OR HEAVY DUTY WHERE INDICATED, OUICK-MAKE, QUICK -BREAK TY`PE. ENCLOSURES, SHALL 13E AS REOUIRED BY NFE.C. AND LOCATION (I-EATHERPROOF, EXPLO51ON-PROOF, ETC). 14. ALL 63�ENERAL PURP05E SWITCHES, AND H05PITAL-65RADE RECEPTACLE-5 SHALL 13E THE PRODUCT OF A 5IN&LE MANUFACTURER, REFER TO 5PECIFICATION5 ON SHEET Ea FOR CATALO 6 NUMBERS. 15. ALL RACEHAY5 AND PIPE-5,5PACED IN OR THROU&H ANY CONCRETE SLAB, SMALL BE SPACED A MINIMUM OF 2" APART TO ALLOW CONCRETE FILI BETWEEN THEM. 1b. IT 15 NOT THE INTENT OF THESE PLANS TO SHOH EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNIS44 AND INSTALL ALL ITEMS, FOR A COMPLETE ELECTRICAL SYSTEM, AND PROVIDE ALL NE-CE55ARY DEVICES AND COMPONENTS FOR EGUIPMENT TO BE PLACED IN PROPER HORK1146 ORDER. 11� ALL ELECTRICAL RACEWAYS (METALLIC, AND NONMETALLIC) SHALL HAVE AN EGVIPMENT &ROUND CONDUCTOR 51ZED IN ACCORDANCE WITH THE 2011 EDITION OF THE NE.C. 1b. LOAD DATA 15 BASED ON INFORMATION 61VEN ENOINEER AT THE TIME OF DE5167N. VERIFY ALL EOUIPMENT NAMEPLATE RATINC-55 BEFORE ORDERINC-7. IcI. CIROUIT5 SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL51ZE5. THE CONTRACTOR 15 TO PROVIDE CIRCUITS AND ROUTINO OF CONDUITS TO WIT JOB CONDITIONS. 20.FURNI5H AND INSTALL V15CONNECT SWITCHES, HIRIN6, AND CONNECTIONS ON AIR CONDITIONINC7 SYSTEM AS SHOWN ON PLANS. ELECTRJOAL CONTRACTOR SMALL VERIFY AND COORDINATE WITH MECHANICAL CONTRACTOR REOARDIN& SUPPLY AND INSTALLATION OF ALL REGUIRED CONTROLS. 21. ALL SHITCH&EAR SHALL 13E THE PRODUCT OF A 51NOLE MANUFACTURER. SYSTEM DE516N IS, BASED ON THE SOUARE 11D11 COMPANY; HOWEVER COMPARABLE EGUIPMENT BY EATON, OFE., AND 51EMEN5 HILL BE ACCEPTABLE. TANDEM AND HALF-5PACE CIRCUIT BREAKERS SMALL NOT BE USED. PROVIDE ARC FLASH HARNINC7516NAOE PER N.E.C. 110.16 FOR ALL5WITCHBOARD5 AND PANELS. 22. ALL UNDEROROUND PVC, CONDUIT RUNS SHALL HAVE RI&ID STEEL E-LBOH5 AND RI&ID STEEL 5ECTION5 AT!5LAf3 PENETRATION5. WHERE RI 61D STEEL 15 USED, IT SMALL BE COMPLETELY COATED WITH AN ALKALI AND RU5T-R.E515TANT BITUMA5TIC, PAINT, AND THREAD5 SHALL BE COATED HITH ZINC CHROMATE. 25. THE ELECTRICAL CONTRACTOR SHALL MEET AND COORDINATE WITH THE LOCAL UTILITY COMPANIE5 AT THE 51TE PRIOR TO CONSTRUCTION. AT THAT TIME, THE CONTRACTOR SHALL COORDINATE ALL RELATED WORK WITH THE UTILITY COMPANIEVREPRE5ENTATIVE-5 TO MEET THE OWNERS SCHEDULE. 24. ALL ELECTRICAL C-ONDUCTOR5 SHALL BE INSTALLED IN AN APPROVED RACEWAY. 25. GONTRAGTOR SHALL BE RESPONSIBLE FOR5EALIN6 ALL CONDUIT PENETRATION5 MADE THROU&H FIRE RATED HALLS, CEILIN66, SLABS, ETC. PENETRATION SEALS SHALL BE PER U.L. ASSEMBLY STANDARDS. 26. CONDUIT 5Y5TEM REOUIREMENT5; UNDER64ZOUND - PVC WITH RJOID cI0 THROU67H SLAB. ABOVE FIN15H FLOOR, CEILINC-75, ETC. (INDOOR) - EMT HITH STEEL SET SCREW FITTINC-75. 67ALVANIZED RIOID CONDUITS - ABOVE 6+2,ADE AND WHERE SUSCEPTIBLE TO PHYSICAL DAMAeE. F1 EXIME CONDUIT5 - INDOOR, ONLY SHORT RUNS NOT TO EXCEED 6-0". 5EALTITE - OUTDOOR, ONLY5HORT RUN5 NOT TO EXCEED 6-0". MG CABLE - REFER TO MC, CABLE NOTES ON TH15 SHEET. 21. CONDUCTOR COLOR CODIN-6: THE FOLLONINO APPLICABLE COLOR CODES, SMALL BE IMPLEMENTED AND POSTED IN ALL PANELS, DISCONNECT SWITCHES, ETC., PER NEC, ARTICLES 200h(D) AND 215.12- 120/24OV., I -PH. PHASE 'Al BLACK PHASE `5' RED NEUTRAL WHITE SSROUND C-AZEEN 150L. &ROUND r7REEN/YELLOH 2&. ALL RECEPTACLES WITHIN 51X FEET OF A HATER SOURCE SHALL BE A &FI RECEPTACLE OR PROTECTED BY A C7FI BREAKER PER NFPA -10 (NEC) ARTICLE 210.&. THIS NOTE APPLIES TO ALL SHEETS. 2cl. PROVIDE ALL REGUIRED 0-10V HIRINO TO O-IOV DIMMABLE FIXTURES, AND CONTROLS AS REMIRED. TH15 0-10V LOH VOLTA(5E HIRIN6 15 NOT SHOWN ON PLANS FOR DRAHIN5 CLARITY, 50. ALL OUTDOOR RECEPTACLES SHALL BE WEATHER RESISTANCE RATED, CSFI-TYPE WITH "WET WHILE IN USE" COVERS, MARKED "EXTRA DUTY" PER 406A 03)(1). 31. WHERE HIRE51ZE5 ARE SHOWN ON PLANS OR IN PANEL SCHEDULE, THE!5AME HIRE SIZE, AS A MINIMUM,5HALL BE CARRIED THROU67HOUT THE CIRCUIT UNLESS SPECIFICALLY NOTED OTHER4-415E ON PLAN5. NqE3 LEOEND E MOUNTINO HEICHT5 SHOWN ARE MAXIMUM/MINIMUM NOT ALL DEVICES SHOWN IN LEOE� ARE REGUIRED. L HAW1CAPf='ED ACCE551BILITY STANDARDS - THEY SHALL REVIEW POWER AND LI(5HTIN6 PLANS AND DETAILS FOR NOT BE ALTERED WITHOUT WRITTEN AOTHORIZATION. ITEMS H[HICH APPLY TO TH15 PROJECT. E 0 LINEAR FIXTURE, LETTER INDICATES TrPE CONIA)IT CONCEALED IN KAkLL OR ABOVE 0MLIN& 04" CONDUCTORS AS SHOWN ON PANEL 5C+IEDULE. UDN. OB INCANDESCENT OR HID LI6HT FIXTURE, LETTER INDICATES TYPE CONDUIT CONCEALED BELOK FLOOR SLAB OR FINISHED 6RAVE T I­0c, KALL BRACKET L16HT FIXTURE, LETTER INDICATES TYPE W" CONVUrTOR5 AS SHOWN ON PANEL 56HEDULE U.O.N. L16HT FIXTURE ON EMER6ENCY CIRCUIT/NI&HT LIr9HT 04L) CONDUIT EXPOSED ON HALL OR CEILIN& NTH CONDUCTOR-57 AS SHOWN ON PANEL SCHEDULE. U.O.N. EXIT L16W (ARROK INDICATES DIRECTION) TELEVISION SYSTEM E!"IPTY CONDUIT WITH PULL HIRE BATTERY POWERED EMER6ENCY LI6HT FLEXIBLE CONDUIT NOT TO EXCEED 6 FEET IN LEN&TH A (1) WAD REMOTE EXTERIOR MOUNTED EMER6ENCY LI&HT. DL. VOLTASE li MO KIRE IN 1/2' CONDUIT) L(Z HEAD REMOTE EXTERIOR MOUNTED EMERiSENC�Y L16HT. HIREMOLD (SIZE AND LEN6TH AS NOTED) TRACK L1644TINO CONDUIT 5EAL--iOFF FITTIN& SINGLE POLE SWITCH, LOWER CASE LETTER INDICATES L16W CONTROLLED, MOUNT 46" A.F.F. U.O.N. PADDLE FAN KITH 5A<J<5OX CAPA13LE OF 5UPPORTIN6 100 L5. LOAD 52 DOUBLE POLE SK11TCH, MOUNT 4&" A.F.F. U.O.N. S5 THREE-KAY SHITCH, MOUNT 46- A.F.F. li 1=A T.V. CAMERA 54 FOUR-KAY SKITCH, MOUNT 468 A.F.F. li T.V. MONITOR 5p 5IN6LE POLE SHITCH WITH PILOT L16HT, MOUNT 440 APF. TELEV`15ION OUTLET, PROVIDE 5IN(5i_E CiAN& BOX KITH 3/4" U.ON. 1-0 CONDUIT WITH PULL WIRE AND IN5ULATINS5 BUS! 11IN& STUBBED INTO 5K KEY OPERATED SIN&LE POLE SNITCH, MOUNT 46" A.F.F. U.O.N. CEILIN& SPACE. MOUNT 13OX 0" AF.F. U.O.N. 5F FAN. CONTROLLER, MOUNT 4&- A.F.F. U.O.N. q:::] DISCONNECT 5JI41TC-44 DIMMER 5WITC44, KATT5 AS NOTED, MOUNT 4,56 A.FF. U.O.N. 1001;31W DISCONNECT DE-516NATION (511ZE/POLE5/FUSE� NF" INDICATES NON-FU51EPI "PE" INDICATES DUAL ELEMENT FUSES. HOSPITAL-C7RADE 5IN&LE RECEPTACLE, AMPS AS NOTED, MOUNT I&N A.F.F. U.O.R MA6NETIC MOTOR STARTER H05PITAL-eRAVE DUPLEX RECEPTACLE, MOUNT le- A.F.F. qO COMBINATION KW_-+4ETIC MOTOR 5TARTEPV15CONNECT SWITCH U.0K @r H05PITAL-64ZADE DUPLEX RECEPTACLE, MOUNT AE30VE RT Dpy TYPE TRANSFORMER COWTER HEIC+ff U.O.N. Pq CONTAC- TOP, (AS NOTEP) HoSpiTAL-&RADE asiAoRAPLEx RECEPTACLE, MOUNT iam A.F.F. U.O.N. MT/,, Tit-e cuxx_ HC15PITAL-&;ZADE DUPLEX RECEPTACLE, HORIZONTALLY Fp_x_1 PHOTOCELL MOUNTED. 5oA I PH, 25ov. RECEPTACLE, AMPS AS NOTED, MOUNT la" A.F.F. MOTOR PERMANENTLY CONNECTED KITH FLEXIBLE C4+10UIT U.O.N. 41H SPECIAL RECEPTACLE AS NOTED ELECTRIC PLrT HEATER 6RADE FLOOR MOUNTED DUPLEX RECEPTACLE THERMOSTAT. PROVIDE 511146LE &AN67 BOX NITH 1/2" 0. STUBBED INTO CEILIN&SPACE, MOUNT 60" A.F.F. U.O.N. (C40FD11NATE NTI4 HOSPITAL-61RADE 6ROUND FAULT INTERRUPTER MECHANICAL PRAKIN66 PRIOR TO ROUe+I-IN) O?m RECEPTACLE, MOUNT ABOVE COUNTEFZ HEli U.O.N. PU5HE3UTTON, MOUNT 45' A.F.F. 1i (��a H05PITAL-64ZADE DUPLEX RECEPTACLE, ISOLATED CiROUND DOOR CHIME KITH TRAN5FORU�IER TYPE, MOUNT AT 1,50 AF.F� U.O.N. Q: H105PITAL-CiRADE DUPLEX RECEf TACLE, SPLIT WIRED, MOUNT SPEAKER I&" A.F.F. U.ON. _UNCTION BOX (f=LLrH MOUNT IN FINISHED AREAS U.ONJ em DUPLEX RECEPTACLE, HEATHER4ZE515TANT AND 6FI RATED, LEVITON #147&qq-TRK WITH WEATHERPROOF 13OX AND VEV:ICE AS NOTED COVER. MOUNT AT I&` APP. U.O.N. TELEPHONE BACKBOARD NTH #b 0J. e4PZOUND (SIZE AS NOTED) DUF`LEX RECEPTACLE P41TH USB CHAR&INe PORTS, HUBBELL #USB2OX2K MOUNT AT 16" A.PF. li 2T7/4WV, 5-PH PANELWARD TELE/PATA OUTLET, PROVIDE 4- 50.5OX NTH kSAWv KV LI&4TINC7 OR POWER PANELBOARD RIN&, AND I" CONDUIT WITH PULL KIRE AND INSULATIN& BUSHIN& STUBBED INTO CEILIN& SPACE. MOUNT A50VE FLOOR MOUNTED TELEPHONE RECEPTACLE COUNTER HEICrHT U.O.N. TELEA:�ATA OUTLET, PROVIDE 4" 50. BOX NTH 1--&AWv KV RIW AND 11- CONDUIT KITH PULL WIRE AND INSULATIN6, BU51i 5TU55EP INTO OEILIN6 SPACE. MOUNT 13OX 16" Ar-.F. U.O.N. 60CE=An E.a. EGAJIPME 6ROLND ENC. ELECTRIC WATER COOLER N.L. NI(9HT L16HT Afj9. ABOVE FINISH 6RADE I.e. 150LATED CROW E/F-EF EXHAUST FAN Pr, FULL C44AIN U.O.K 1i OTHERWISE NOTED w HEATHERPROOF AAi­AHU AIR HANDLIN5 UNIT C.T. CUIZRENT TRAW5FOM-M NTiS. NOT TO 5CALE E6 EMPTY CONDUIT A60-61) CONDEN5W UNIT EX EX15TINC7 DEVICE N.I.C. NOT IN CONTRACT EWH ELECTRIC WATER HEATER RTU ROOF TOP UNIT EXR E45-nN5 TO BE RELOCATED AI.F.F. ABOVE FINISH FLOOR 6FIi 6ROUND FAIJLT CIRCUIT INTERRUPTER NOTEx MOWTIN& HE1160M NOTED ARE TO CENTERLINE OF DEVICE %IOW UO.N. MG GABLE NOTES E. -,:a 0#X011.11 Q IPM 04 0 W-41 W01 R0190 Q, 1q;a I M1 qlal� 1911 urdep.10 :%A wArial IN it I gm • BRANCH CIRCUIT5 MAY 13E METAL CLAD CABLE TYPE (MG), PROVIDED: • CABLE SHALL BE 'HEALTH CARE FACILITY METAL CLAD CABLE' TYPE MCF) ONLY, IN COMPLIANCE P41TH NEC 511.13 (A)(5). * LIC7HTINO CIRCUITS ABOVE V-O" ONLY; CABLE MAYBE 'METAL CLAD CABLE' TYPE (MC). • LI &HTIN& CONTROL SWITCHES, CA13LE SHALL BE 'HEALTH CARE FACILITY METAL CLAD CABLE' TYPE (HCF) ONLY, IN COMPLIANCE WITH NEC 511.15 (A)(5). • WHERE PANEL 15 FLUSH MOUNTED THE CABLE SHALL RUN IN HALL CAVITY. M2A WHERE PANEL 15 SURFACE MOUNTED: CONTRACTOR SHALL PROVIDE METAL5TUD5 WITH DRY1,4ALL TO CREATE A CAVITY TO RUN THE MO CABLE WITHIN. • MC CABLE MAY 13E USED FOR 20 AMP CIRCUITS IN WALLS OR ABOVE ACICE551BLE CEILIN675. • MC, CA13LE HIRE OAL6E-55HALL BE AS SHOWN ON PANEL SCHEDULE. • MC CABLE SHALL ONLY BE USED WHERE ALLOWED BY N.E.C. SECTION 530.10, WHERE APPROVED BY THE BUILDINO OFFICIAL, AND ACCEPTED BY THE OWNER. • MO CABLE5HALL BE INSTALLED PER N.E.G. 550. • ALL GABLE RUNS SHALL BE CONCEALED FROM VIEW AND ROUTED PARALLEL AND PERPENDICULAR TO BUILDINO LINE-5. • MG GA13LE MAY NOT BE USED IN OPEN STRUCTURE AREA, EXPOSED, OR OTHERH15E VISIBLE TO C,U5TOMER5. N43A DEMOLITION NOTES 1. ELECTRICAL PLANS DO NOT INCLUDE A DEMOLITION PLAN FOR THE E RENOVATED AREAS. THE RENOVATED AREAS, INCLUDIN& WALLS, OEILIN6�6, ETC., TO BE REMOVED, ARE SHOWN ON THE ARCHITECTURAL N PLANi MAJOI;z MECHANICAL EGUIPMENT TO BE REMOVED 15 SHOWN ON THE MECHANICAL PLANS. CONTRACTOR SHALL REVIEW THESE PLANS E AND COORDINATE WITH THE &ENERAL CONTRACTOR ON 51TE TO THE DETERMINE THE EXTENT OF THE DEMOLITION WORK AND PROJECT f;Z PHA5IN& REMIRED AND PROVIDE AC.GORPINOLY. ALL ELECTRICAL DEMOLITION WORK SHOWN OR IMPLIED IN THE El ECTRICAL, MECHANICAL, A PLUt-15IN6, AND ARCHITECTURAL PLAN55HALL BE PART OF THE Ell ECTRICAL CONTRACTORS WORK. L 2. ELECTRJOAL DEMOLITION WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, REMOVIN& LI 6MTIN & FIXTURES, RECEPTACLES, HIRE, 0ONDUIT, ETC., AS RE69JIRED FOR THE INSTALLATION OF NEW EMIPMENT AND REMODELIN& OF THE EX15TIN&FACILITY AS INDICATED ON THE PLANS. 3. CONTRACTOR SHALL REMOVE ALL F-XP05ED HIRE, CONDUIT, HANC-A=-R5, CLAMPS� ETC. 4. EXISTIN& HIRE AND CONDUIT!5 C.,ONCEALED ABOVE CEILIN6 OR IN WALLS AND NOT 5EIN&REU5ED SHALL BE REMOVED. EX15TINO GONDUIT5, MERE APPLICABLE, MAY 13E REUSED. 5. ALL LI&HTIN& FIXTURE5 5EIN6 RELOCATED OR SHOWN ON PLANS DENOTED P41TH (EX) SHALL BE CLEANED, RE-LAMPED, AND REPAIRED TO PROPER HORKIN& CONDITION IF REGUIRED. (b. CONTRACTOR SHALL V151T THE JOB SITE AND BE THOROUCSHLY FAMILIAR WITH EX15TINC7 CONDITIONS, UNDER WHICH THE P40RK MUST BE PERFORMED. -7. ALL LIC7HTIN6 FIXTURES AND LAMF5 BEIN& REMOVED SHALL BE DISPOSED OF IN AN ENVIRONMENTALLY SAFE MANNER. GOOfRDINATE D15PO51TION OF ALL FIXTURES WITH OWNER PRIOR TO REMOVAL. ALL POWER D15RUPTION5 OR OUTA5E5 REWIRED FOR THE BUILDINC-7 5ERVICE-5 SHALL BE C-OORVINATEI? WITH THE 6ENERAL CONTRACTOR, 5UILVIN& MANA67EMENT, AND CURRENT TENANTS 4eo HOURS PRIOR TO THE D15RUPTION OR OUTAC7E. THESE NOTES APPLY TO ALL ELECTRICAL SHEETS. N15A 01 NOTES 011 1. IT 15 THE CONTRACTORS RE5PONSIBILITY TO REVIEN ALL DRAHINC-5 0 AND SPECIFICATIONS, INCLUDIN& BUT NOT LIMITED TO ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUM51N6, AND ELECTRICAL PRIOR TO N 5U5MITTIN0 A BID. T 2. REPORT ANY V150REPANCIE5 TO ARCHITECT OR EW-71NEER PRM TO BID. 3. BIDDERS ARE TO V151T THE 51TE AND FAMILIARIZE THEM5ELVE5 WITH EX15TIN6 CONDITIONS AND 5AT15FY THEMSELVES AS TO THE NATURE A AND SCOPE OF THE How. 4. IT 15 THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL EX15TIN6 51TE T CONDITIONS INCLUDINC? BUT NOT LIMITED TO, SERVICE LOCATION, SERVICE LAYOUTS, AND TELEPHONE LOGATION., ETC,. 5. THE SUBMISSION OF A aic> HILL BE r=viDENCr= THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EOUIPMENT, OR MATERIALS REQUIRED, OR FOR ANY DIFFICULTIES ENCOUNTERED MICH COULD HAVE BEEN FORESEEN HAP AN EXAMINATION BEEN MADE, HILL NOT BE ALLOWED. 6. IT 15 THE RE-5PON515ILITY OF THE GONTRACTOR TO NOTIFY THE ARCHITECT OF ANY D15CREPANCIE5 ENCOUNTERED ON THE PLAN5 OR IN EX15TIN6751TE CONDITIONS PRIOR TO SOBMI55ION OF BID. 1. COORDINATE WITH OTHER TRADES FOR ITEMS IN THEIR SCOPE OF V40RK WHICH WOULD REGUIRE ELECMGAL HORK (DISCONNECTION, RE00NNECTION, ETC) AND ARE NOT INDICATED ON ELECTRICAL DRAHINC-55. THESE NOTES APPLY TO ALL ELECTRICAL SHEETS. W. �. I I TRANSFORMER LOCATION - FIELD VERIFY PRIOR TO 51D NEW SERVICE LOCATION I 5HEETINDEX i El ELECTRICAL NOTES AND LEC-END E2 LJOHTINO PLAN E5 LI&HT FIXTURE SCHEMLE AND DETAILS E4 POWER PLAN E5 ELECTRICAL DETAILS, E6 POWER R15ER DIA&RAM E77 PANELBOARD 5CHEMLE5 E& ELECTRICAL5PECIFICATION5 R35 NcIRTH ELEGTRIGAL SITE MAP NO 50ALE CHEHAYEB & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS 3702 AZEELE ST. (8f3) 876-14f5 TAMPA, FL 33609 wurmchehayeb.com LIC. #49521 SOUHEIL S. CHEHAYEB CERT. #7340 21-117 issue Date 09-03-21 6 c (00 _c < LL < Z M J z 0-11 E D MQ �_ (0 CO 0 _j - N - co 8 0 w 6 cu CL 0 :3 LL 0 - 0 L_ U) (D _=c > 0 c- CIO W N (D M 0 -17 4- 0 _0 c: E E 0 _0 2t N co I! Job Number 2008 Revisions ELECTRICAL NOTES AND LEGEND 0-:>" CO No. 495 40- OF AA got No. El 11 11 h i 1 1, �' 'I ­ I it. a N i I ih I , li I 1 11; 1 1 1 1 LAB/ NEHEREAK, NEH STERILIZATION QF�FAK 2 g, F7j5 F 116 P) FAMILY FAMILY Ex6ti �� EXAM 2 CORR K FAMILY EX A-M I PROVIDERS ADA PEDIATRIC TOILET 3 EXAM -1 EX15T EXIa I UTILI F-2-21-1--i 12:20 PEDIATRIC PADIATI;PIC Issue Date L&A� f2 EXAM 5. r-= I= 09-03-21 E rm E NU 1-TA&IN I lu-t I I a.-> cl �- OGGUPANGY/VAGANGY 5EN50R DEVIGE LFOEND ITEM MANUFACTURER CATALO& NO. DESCRIPTION LINE VOLTA6E - HALL VACANCY SEN50R HiTH ON AND OFF CONTROL LINE VOLTACSE (120-2-M) HALL MOUNTED 5EN50R ks6XPDT-5A VACANCY 5EN50R HITH IbO DE6REE5 'Ll S 5HITCH (DUAL TEGHNOLOC-7Y) DETECTION, ADJUSTABLE CSHTS OFF TIMER AND OVERRIDE 5HITCH. SET AS MANUAL ON - AUTO OFF. LINE VOLTA65 - CEILINO MOUNTED OCCUPANCY 5EN50P, LINE VOLTA6,E (120-2-n) CEILINO MOUNTED 5EN50R 5HITCH GMR-PDT--q (DUAL TECHNOLO&Y) OCCUPANCY 5EN50R HlTH 360 DEC7REE5 OF DETECTION AND Ar,>JUSTABLE "LIC71-IT5 OFF" TIMER. LINE VOLTA6E - DIMMER / VACANCY 5EN50F, 6ONTROL HALL MOUNTED LINE VOLTA67E DIMMER/ - OM 5EN50R H5X-PDT-r,>-SA VACANCY SENSOR HITH 1&0 DECvREE5 S 5HITCH (DUAL-TECHNOLOC7Y) DETECTION, ADJUSTABLE "I-161-ITS OFF TIMER" AND OVERRIDE 5HITCH, SET AS MANUAL ON AND I I AUTO OFF. 0-10 VOLT HALL CONTROL - DIMMER 5HALL BE OOMPATIBLE H" LIC-+fT FIXTURES PROP05ED 0-10V GOORDINATE- HITH HALL MOUNTED O-IOV DIMMER. PROVIDE S 0 DIMMER FIXTURE 0-10V HIRINO TO ASSOCIATED FIXTURE-5 MANUFACTURER AS REQUIRED. NPODM-DX-GBA S�L (AT EACH 5HITCH HALL 5HITCH ON/OFF + RAISE LOkF--R LOCATION). pp NPP16-1?-5A POl^IER PACK HITH 0-10V DIMMINO - VACANCY SENSOR 5HITCH (ONE PER LOAD) MOVE NCMPVT-1-RJ45 nm (AS REQUIRED LOH VOLTA&E OCCUPANCY SENSOR FOR COVERAC5E) 1. PROVIDE ALL MOUNTINO ACCE-55ORIE5 AS REQUIRED. SET TIME DELAY TO OFF AT 30 MINUTES, UNLESS NOTED OTHERHISE. 2. DEVICE AND COVER PLATE-55HALL BE HHITE- -3 � NOT ALL DEVICES MAY BE USED. REFER TO PLANS FOR APPLICABLE ITEMS. 4. ALL HIRIN6 FOR OCCUPANCY/VACANCY SEN50R55HALL BE PER MANUFACTURER INSTALLATION SHEET PROVIDED P41TH PRODUCT. 5. PROVIDE DIMMINO CONTROL HIRINO AS REQUIRED. DIMMIN5 CONTROL HIRIN6 ARE NOT 5HOHN ON THE PLANS FOR DRA"IN67 CLARITY. CONTRACTOR SHALL VERIFY TYPE OF DIMMIN& CONTROL HIRIN& BEINO CLASS I OR CLA55 2 AND PROVIDE AGGORVIN61-Y. L��/-\ C'l � I I - I I I M-j 1--ul I f I 'e- I..a I I - 2020 FLORIDA BUILDING CODE, ENERGY CONSERVATION (7TH EDITION) SECTION C405.5 ELECTRIC POWER G405.53 VOLTA67E DROP THE CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS COMBINED SHALL BE SIZED FOP, A MAXIMUM OF 5% VOLTA&E DROP TOTAL. 0405.5.4.1 DRANINC-7-5 CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT HITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAHIN&S OF THE ACTUAL IN5TALLATION!5HALL BE PROVIDED TO THE BUILDINO OHNER, IW-,LUDIN&- 1. A51N&LE-LINE DIACGRAM OF THE BUILDIN& ELECTRICAL DISTRIBUTION SYSTEM AND 2. FLOOR PLANS INDICATINC7 LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. --- ------- ----- - C405.5.4.2 MAW- AI-5 CON5TRUr-,TION DOCUMENTS SHALL REQUIRE THAT AN OPERATINO MANUAL AND MAINTENANCE MANUAL BE PROVIDED TO THE BUILVIN& OHNER. THE MANUAL5 SHALL INCLUDE, AT A MINIMUM, THE FOLLONINC-7: 1. SUBMITTAL DATA 5TATINC-7 EQUIPMENT RATINO AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REGUIRINC? MAINTENANCE. 2. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRIN& MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. 3. NAME-5 AND ADDRESSES OF AT LEA!5T ONE QUALIFIED SERVICE ArvENCY. SECTION C408 SYSTEM COMMISSIONING . . ................. ...... . ... ......... . ...... ............ . ........... . UNC�JION& lfaftCz- 1. PRIOR TO PA551NO FINAL IN5PECTION, THE RE615TERED DE51 ON PROFESSIONAL SHALL PROVIDE EV10ENCE THAT THE I -I &I-ITINO CONTROL SYSTEMS HAVE 13EEN TESTED TO ENSURE THAT CONTROL HARDHARE AND 5OF-11-4ARE ARE CALIBRATED, ADJUSTED, PROORAMMED AND IN PROPER HORKIN& CONDITION IN ACCORDANCE V41TH THE CONSTRUCTION 006,UMENTS AND MANUFACTURER'S INSTRUCTIONS. FUNCTIONAL TE5TIN& SHALL BE IN ACCORDANCE HITH SECTIONS 0409>311 THROU6?H 0405.3.1,3 FOR THE APPLICABLE CONTROL TYPE. 640&.3.2 2QCeQMENTATION KMInMENT!5; 1. THE CON5TRI)CTION DOCUMENTS SHALL SPECIFY THAT DOCUMENTS OF50RIBED IN TH15 SECTION BE PROVIDED TO THE BUILDINC-7 OHNER5 i AUTHORIZED AC -ENT HITHIN cIO DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. N40A r NOTES E (D JUNCTION BOX HITH 120V 5P5T MAINTENANCE5HITCH FOR, BUILDIN& 516N. COORDINATE EXACT LOCATION PRIOR TO ROU&H-IN. Y LI&HTINO CONTROL PANEL (LCP). REFER TO DETAILS ON 5HEET E3. LCP OVERRIDE 5HITCH. REFER TO DETAILS ON SHEET E3. OCCUPANCYNACANCY SENSOR. REFER TO5EN5OR LECEND ON TH15 SHEET. VACANCY5EN50R HITH DIMMIN67. REFER TO 5EN50R LE&END ON TH15 SHEET. 0-10V LED DIMMER. REFER TO 5EN50R LE615ND ON TH15 SHEET. CIRCUIT CONTROLLED VIA LCP. REFER TO CONTROL 50HEDULF ON SHEET E5. LON VOLTAC-7E, CEILIN6 SENOR COMPONENT. REFER TO SENSOR LE6;,ENV ON THIS SHEET. Pf;zo\/iDE PoHER AND CONNECTION TO OHNER SELECTED 5UP,61CAL/EXAM LI(5HT. VERIFY IN5TALLATION REQUIREMENTS V41TH MANUFACTURER PRIOR TO ROLh:F7H-IN. 01 NOTES & 1. REFER TO ARCHITECTURAL REFLECTED CEILIN& PLAN AND E INTERIOR ELEVATIONS FOR C4)ORDINATION OF ALL LIC-71-ITINC-7 FIXTURE LOCATIONS. N 2. &ROUND roNDtk,-ToR5HALL EW-- INSTALLED IN Ewif;zE E RACEHAY 5Y5TEM INGLUDIN& HALL 5HITCHE5 AND FLEXIBLE CONDUIT TO LIC-MT FIXTURES. 3. LI 6MTltr0 5NITCHES SHALL BE OROUPED HiTH ONE PLATE AND A LOCATED APPROXIMATELY 2 INCHES FROM DOOR FRAME (5TRIKE SIDE) UNLE55 OTHERH15E NOTED. L 4. CONDUIT AND HIRE 5YSTEM5 FOP, ALL PATIENT CARE AREAS, EXAM ROOMS, TREATMENT AREAS, ETC., SHALL COMPLY HITH REQUIREMENTS FOR REDUNDANT (57ROUNDINO PER MC METAL CLAD CABLE NOTES ON SHEET EI.O� 5. ALL EMER&ENC-'r BATTERIES, EXIT LI&HT5, AND NI 6yHT LIC7HT5 SHALL BE HIRED AHEAD OF LOCAL CONTROLS AND RELAY PANEL CONTROL RELAYS. LIOHTINO PLAN, 50ALE: 3/16" = 1'-0" NORTH NQ�ll REFER TO SHEET E5 FOR LIC-71-ITINC-7 FIXTURE SCHEDULE. NEH AND EX15TINC9 CONDUIT AND HIRE SYSTEMS FOR ALL PATIENT CARE AJREA5 SHALL COMPLY HITH REQUIREMENTS FOR REDUNDANT C-4RDUNr,>INr9 PER N.E.C. ARTICLE 511.13 (A)(5). FIELD VERIFY ALL EXISTIN& CIRCUITS TO REMAIN AND RECIRCUIT IF REQUIRED. W�A 2020 FLORIDA ENERGY CODE C405.2.3 DAYUGKr-RESPONSIVE CONTROLS COMPUANCE STATEMENT 101 NOT REQUIRED PER C405.2.3(l) 105 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 116 NOT REQUIRED PER C405.2.3(l) 201 NOT REQUIRED PER C4052K(1-) 210 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 212 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 213 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 214 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 215 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 217 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 218 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 220 NOT REQUIRED PER C405.2.3(l) 223 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 228 NOT REQUIRED PER C405,2.3(l) 229 NOT REQUIRED PER C405.2.3(l) 234 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 235 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 236 NOT REQUIRED PER C405.23 (EXCEPTION 1) 238 NOT REQUIRED PER C405.2.3(l) 246 NOT REQUIRED PER C405.2.3 (EXCEPTION 1) 250 NOT REQUIRED PER C405.2.3 (EXCEPTION 1 2Y; N REQUIRED PER C405.2.3(l) CHEHAYEB & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS 3702 AZEELE ST. (813) 876-14f5 TAMPA, FL 33609 www.ch--hayeb.com LIC� #49521 SOUHEIL S. CHEHAYEB CERT. #7340 21-117 4- tLI c- 1�- L) < < Z Z 0, LL :) E c OD co 00 0 w moo 6 co a.2 :3 LL c: 0 0 L. m 0 c- > 0 (D N (D 4-4 (D 42 1:� 4-4 0 E a E 1-� E JIM 0 c- 0 Revisions Z� Z� L F I XTURE 50HEDULE L `rrM MANWACMA;r:R CATAA-06 NO. DESCRIPTION VOLT I t-AMI'15 MOMTIN& KATTS I A LITHONIA OPANL-2XA- 2x4 LED FLAT PANEL 120 (5000 LUMEN LED LAY -IN 55 AL065HW7M2 4000K H— AE LITHONIA CPANL-2x4- Ai_0bSNWM2- 2x4 LED FLAT PANEL 120 6000 LUME�- LED LAY -IN 55 T lLf3LPCPIOHE-5DA NITH BATTERY 4000K I N 5 LITHONIA CPANL-2x4- AL065k4-l7M2- 2x4 LED FLAT PANEL 120 5000 LUMEN LED 4000K LAY -IN 45 BE LITHONIA CPANL-2x4- ALO&%�WM2- 2)<4 LED FLAT PANEL 120 5000 LUMEN LED LAY -IN 45 IL5LPCPIOHE5VA HITH BATTERY 4000K LITHONIA CPANL-2x4- 2x4 LED FLAT PANEL 120 4000 LUMEN LED LAY -IN 56 AL06SHWH2 4000K CE LITHONIA CPANL-2x4- AL0&SkqN7M2- 2>(4 LED FLAT PANEL 120 4000 LUMEN LED LAY -IN 36 ILBLP OPIO HE5DA HITH BATTERY 4000K FPANL-2x4-3000LM- 2x4 LED FLAT PANEL 5000 LUMEN LED DE LITHONIA 50 CRI-55K-MINI- HIT14 BATT'ERY 120 4000K LAY -IN 2q ZT­MVOLT_EIONGp F LITHONIA LPN&-55/15-LO&-AR- 6" LED DOHN L16HT 120 1500 LUMEN LED RECESSED I& L55_MV0LT_c7zI 40OCK a LITHONIA ZLIN-L24-25OOLM-F5T- 24" LON6? LED LENSED 120 2500 LUMEN LED k4ALL ABOVE Ict MVOLT-4OK-e0�,R144H 5MP LI&HT 4000K DOOR H LIT`HONIA GPANL-2x2- 2X2 LED FLAT PANEL 120 3300 LUMEN LED LAY -IN 31 ALOISP4-tH4 4000K HE LITHONIA OPANL-2x2- ALOI5W-nM4- 2x2 LED FLAT PANEL 120 5500 LUMEN LED LAY -IN 31 lL5LP6PlOHE5DA k4ITH BATTERY 4000K RH LITHONIA ELMRk4LP220LT-(6BA) THO-HEAD OUTDOOR 120 LED 1,4ALL EGUAL TO TOP OF DOOR - REMOTE EMERC7. LIC7HT X LITHONIA L0M5k-aR-120/2T7-ELN-5D LED EXIT5I(9N 120 LED UNIVERSAL I kqITH BATTERY LED EXIT SION k4ITH UNIVERSAL XR LITHONIA LHOM-LED-R-HORO BATTERY AND REMOTE 120 LED 4 CAPACITY. C,5A = COLOR AS SELECTED BY ARCHITECT. NOTES: 1. PROVIDE NECE-56ARY 1�,IOUNTIN& HARPHARE AND SHOP VRA"IN(55 SHALL INCLUDE COMPLETE FIXTURE CUT ACCESSORIES, FIXTURE5. ACCESSORIES, SHALL INCLUDE ALL SHEETS, INCLUDINCY PHOTOMETRiC5. HARDNARE TO MOUNT FIXTURES AS SHOM ON SCHEDULES ANWOR 0155CR15ED IN THE NOTE5. q. UNLES5 OTHERHISE NOTED, (NQ DENOTES A NI(5HT LIC7HT' FIXTURE. NIC7HT LIC7HT FIXTURES SHALL BE UW"ITCHEV. 2, ALL FIXTURE 5UE6TITUT*ION5 MUST 5E SUBMITTED FOR EMER6,ENGY BATTERY SHALL BE TIED TO A CONSTANT HOT APPROVAL (EG?UAL!5 ONLY). AHEAD OF LOCAL 5HIT(5HINr5 AND/OR CONTROL PANEL. 5. ALL EMER5EW_,Y, EXIT, AND NIr_­HT LIC-HT FIXTURES 544ALL BE 10. BATTERY IN THE FIXTURES SHALL BE UL c124 L15TED AND (�,ONNECTED AHEAD OF LOCAL 5NITCHE-5, RELAYS, OR COMPLY HITH NFPA 101 LIFE 5AFETY' CODE SECTION 7.4. THE CONTACTORS UNLE-55 OTHERA15E NOTED. 5Y5TEM SHALL BE PERIODICALLY TESTED PER NFPA 101 SECTION 4. ALL PRE SUBMITTALS, SHALL 13E ACCOMPANIED NITH PHOTOMETRIC DATA. 11. PROVIDE ALL REMIRED O-JOV NIRJWv TO 0-10V DIMMABLE FIXTURE5 AND CONTROLS AS REQUIRED. TH15 040V LOH 5. ALL FIXTURES 514ALL BE SUPPORTED FROM STP44TURE AND VOLTAC-A=- kqIRIN6 15 NOT SHOHN ON PLANS FOR DRAKIN& NOT FROM 5U5PENDW CEILIN6 SYSTEM. CLARITY. 0-10V KRIN& SHALL BE TYPE COMPATIBLE NITH THE FIXTURE DIMMIN& DRIVER TYPE (CLA-% I OR 2). CONTRACTOR ro. EOUAL ACCEPTED MANUFACTURERS ARE: DAY-13RITE, COOPER, 514ALL COORDINATE NITH MANUFACTURER FOR 6A5LE TYPE, COLUMBIA. SIZE, AND INSTALLATION REQUIREMENT AND COMPLY ACCORDINC-LY. ALL HIRINry SHALL BE IN COMPLIANCE KTH T CATALO& NUMBER ON FIXTURE SCHEDULE MAY NOT REFERENCE N.E.C. ARTICLE125. EVERY HARDKAiRE COMPONENT REQUIRED TO MOUNT FIXTURE AS INTENDED, VMfFY WITH MANUFACTURER FOR PROPER MOUNTINry HARPKARE AND ANY ADDITIONAL COMPONENT5 REWIRED TO MOUNT FIXTURE AS INTENDED OR SHOHN. 54A 'LGP—A'V4IRIN6 DETAIL L el I d) —4 & I H T LIC-7HTINO CONTROL PANEL A 'LcP-Al N 00 6 A -5:2 r G LIC2:HTINC7 CONTROL E6NEL - DETAIL NO SCALE (BLUE BOX) 0 (D LI&HTIN& CONTROL PANEL EGUAL TO BLUE E30X N #OR141&-LT-ENO-FM-NEI/6RI416-LT-INT-16NOL-Fr=MOTE-DV. T 120V,.20 AMP CIRCUIT BREAKER NITH LOOK -ON HANDLE FROM DE-516NATED PANEL. 5UR<5E 5U�E550R, EOUAL TO SOR&E 5UPPRE55ION INC, CAT. NO. 0 5-5FT-120. (12OV, 20AMP, SERIES UNIT). L cAT-5F CABLE To MASTER PAWJ- 'LrP-'3'. CAT-515 CABLE AS REGZUIRED IN 3/4" CONDUIT. P BRICMTON5NITCH, BR240OLOR TO MATCH OTHER DEVICE5 USED IN5AME A SPACE), (2) BUTTON PR06RAMMED AS -2-HR OVERRIDE ON' AND Tf-E 'ALL SECOND BUTTON AS OFF'. LOCATION PER PLANS. N SEE RELAY SCHEDULE TH15 SHEET AND PAWL SCHEDULE ON SHEET E7. E L 'LGP—A'LOA0 PANEL 5GHEDULE RELAY FUNCTION CONTROL METHOD 120V CONTROL ON OFF # CIRCUIT 5NITCH RI L I 644T IN 67 TIMECLOOK TIMEOLOCK 0-3 A R2 TENANT SION PHOTOCELL TIMEOLOOK G-71 R3 L I &HT IN& TIMEOLOCK TIMEOLOCK 15�6 A R4 TENANT 5I&N PHOTOCELL TIMECLOCK 5-2 R5 LI&HTIN& TIMECLOOK TIMECLOCK A-53 A Rrb LI&HTIN67 TIMECLOCK TIMECLOCK A-35 A Rl TENANT 51 ON PHOTOCELL TIMECLOGK A-44 RID SPARE Rcl SPARE RIO SPARE f;zII SPARE R12 SPARE R13 SPARE - R14 SPARE - R15 SPARE - Rib SPARE - C&W-96L NOTES: 1. LI&HTIN6 CONTROL PANEL 5HALL BE IN COMPLIANCE P41TH FLORIDA BUILDIN67 CODE 2020 ITH EDITION. 2. OVERRIDE 5V41TCH SHALL ONLY CONTROL TIMEOLOOK ON/OFF OPERATED CIROUIT5. L245 'LGP—f3'V4IRIN& DETAIL L Q�_ FV_G I 6 H T Llr5HTIN& CONTROL PANEL N (DO 0 P-1 V r LIQh4TINQ7 CONTROL PANEL - MAIL NO 50ALE (BLUE BOX) 0 LIC7HTIN& CONTROL PANEL EGUAL TO BLUF E30X N #6RI405-LT-F-NC,!5M-NEI/-CR140&-LT-INT-4NOL-DTG-L>'V. T 12OV, 20 AMP CIRCUIT BREAKER 114IT14 LOOK -ON HANDLE FROM DE51(5NATED PANEL. WF;Uv-E SUPPRESSOR, EGUAL TO 5UR67E 5OPPRE55ION INC. CAT. No. 0 5-5PT-120.020V, 2OAMP,5ERIE5 UNIT). L DirvITAL OUTDOOR. PHOTOCELL, PCELL-21^1055, MOUNTED ON THE ROOF FACINC7 NORTH. GAT-5E CABLE AS REWIRED IN 3/4" CONDUIT. p A BRI &HTON 5114ITCH, BR246OLOR TO MATCH OTHER DEVICES USED IN SAME SPACE), (2) BUTTON PRO&RAMMED A5 -2-HR OVERRIDE ON' AND THE N SECOND BUTTON A5 'ALL OFF'. LOCATION PER PLAN6. E SEE RELAY 50HEOULE TH15 SHEET AND PANEL SCHEDULE ON SHEET E"l. L 3 #15 IN 3/4" CONDUIT. CAT-5E CABLE TO REMOTE PANEL tCP-A'. PANEL 'LGP—f3' LOAD 5GHEPULE RELAY F`UNCTION CONTROL METHOD 120V CONTROL ON OFF # CIRCUIT 5HITCH RI LIC7HTINC:7 TIMECLOCK TIMECLOGK D-3 a R2 TENANT 516N PHOTOCELL TIMEOLOCK D-5 R3 SPARE R4 SPARE R5 SPACE ONLY Rlb SPACE ONLY R-t SPACE ONLY R413 SPAGE ONLY C7F_f,r-_RAI hQJC�2- 1. LI6,HTIN& CONTROL PANEL SHALL BE IN COMPLIANCE V41TH FLORIDA BUILDIN6 CODE 2020 ITH EDITION. 2. OVERRIDE 5NITCH5HALL ONLY CONTROL TIMEGLOCK ON/OFF OPERATED CIRCUITS. L245 CHEHAYED & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS 3702 AZEELE ST. (813) 876-1415 TAMPA, FL 33609 wuu.chehayeb.com LIC. #49521 SOUHEIL S. CHEHAYEB CERT. #7340 21-117 Issue Date 09-03-21 d c T U_ < Z m_j Z 0- LL :) E c 00 0 M (D .Z 0 w 6 C U_ c: 0 0 (D > 0 CL c- 0) (D N ry _c W co 0 -17 4- c, 0 _0 c- E E 0-0 _0 CL W Iral -7 2 il, 1� I W4611,; Revisions 15 Q \71-': M5111 q� r AR j-5 ,Zl\ EXIST ELEc 411 QEEF,6T-QR'r 4 15 Ki � 115,---, 15 It J, (TYP DI-cl 111,14 11 106 u D, -7 GORR B -�&j (TY`P-) PANO� - � z bib U)(EX) \\21 rnpp EX15T I t \--/� lur CORRIDOR a 2 FAMILY / 5 OFFICE 2 GORRI OR j AI-2,4 A-2-7 Al-15 F AHU-2 -1 ie EXAM (EX) (EX� L — — C-25 Q -J(EX) Al-je,2o 4 (EX) j V H AHU-4 (NO �3 MED PROVIDE Al -lb (F- X) (Ex) 5UPPLY &FL (Ex) EXIST D-2,4 (EX) TOILET (EX) (EX) EX15T ADMIN (E><) A --ADA (EX) TOILET 2 CORR p CORR L OF I (EX) (EX) < (EX) OFFICE iC�� (EX) (EX) [> (EX) (EX) :0 (FX� OR PEDI 4 L NURSES (EX) EXIST J� OFFICE STATIC) (EX) OFFICE I OF 1 (r=xj (Ex) MANA5ER 'LAB /12061 &Ft (EX) 6, F I 4 FAMILY EXIST (Ex) 6A 12 > 4 R/', 3 EXAM 5 TOILET 5 EX15T. a�o* (EX) 4 (Ex) FAMILY lEX) Al- BLOOD 24 NEL^�RN5 NURSES COMMUNITY iQ (EX) (EX) �E-X) (EX) SERVICE (Ex) 5TATION FAMILY (EX) (EX) Al-14 Al-22 -Q 10 NH -------- jQ(EX) EXAMA VITALS REGEPT/ 2 E-2 —52- � — :c F- 1-101221 ADMIN (Ex) 1-7> (EX)(��l ---\ — , --, - -� C I lb SCALE (EX) (Ex) (EX) -"(EX) (EX) (F4 (EX) (fl) (EX) (EX) (EX) (r=XJ (EX) (Ex) (Eyl) OEX) (E>O CORRIDOR E FAMILY A-4 �Ex) EXAM fn 7f AI-1,3 C,(ORRIDOR N CORR A 5 Y, '7 21 ENTRY LOBBY ADA FATIERIEj OF1 "7 PRIVATE OPERATORYI I Ll I JEJJ OUTLET DQXF-5 IN FIRE RATED HALLS A UL CLA551FIEr,> HALL OPENINO PROTECTIVE MATERIAL (COMMONLY KNOHN AS "PUTTY PADS" OR "INSERT PADS") SHALL BE USED IN THE FOLLOHINO rA5E!5: NHERE BOXES ARE INSTALLED IN FIRE RATED HALLS • HHERE THE OPENIN05 IN T44E HALL BOARD FACE ARE OUT 50 THAT THE P15TANCE BETHEEN THE BOX AND THE HALL BOARD EXCEED 11V' • THE HORIZONTAL SEPARATION OF BACK TO 13ACK OUTLETS 15 LF55 THAN 24 INCHES • THE INDIVIDUAI OUTLET (OR 5NITCH) BOXES EXCEED AN AREA OF 16 SQUARE INCHES THE ENTIRE 5MFACE AREA OF THE 13OX EXCEEDS 100 50UARE INCHES IN EVERY 100 5GUARE FEET OF HALL SURFACE. NOTES E 1. VERIFY/rOORDINATE THE EXACT LOCATION OF OUTLETS LOCATED IN OR AE30VE BASE CABINETS. REFER TO SECTIONS/DETAILS ON N ARcHITETLRAL DRAHIN&S. E 2. C-ROUND C.�ONDUGTOR SHALL BE INSTALLED f;Z IN ENTIRE RACEHAY SYSTEM. A 5. ALL TELEPHONE/VATA/VOIGEJACK5 AID CABLINO TO BE- PROVIDED AND INSTALLED L BY TENANT'5 VENDOR. DENTAL HAITI 5PEC,IAL RECEPTACLE NOTE: ALL RECEPTACLE GOVERPLATE5 SHALL HAVE THE DEVICE'5 CIRCUIT (PANEL AND CIRCUIT NUMBER) AFFIXED ACRO55 THE TOP OF THE PLATE HITH 5116" HEIC-HT BLACK TEXT ON CLEAR 5ELF-ADHE51VE TAPE. NEH AND EX15TIN& CONDUIT AND HIRE SYSTEMS FOR ALL PATIENT CARE AREA55HALL COMPLY HITH REGUIREMENT5 FOR REDUNDANT &ROUNDINC-7 PEP, N.E.C. ARTICLE 51-1.15 (A)(13). FIELD VERIFY AJ-L EX15TINe CIRCUITS TO REMAIN AND RECIR>CUIT IF REWRED. N48,A . .. . . . ........... . ...... SPECIAL RECEPTACLE NOTE; ALL RECEPTACLE COVERPLATES SHALL HAVE THE DEVIGE'5 CIRCUIT (PANEL AND CIRCUIT NUMBER) AFFIXED AGRO55 THE TOP OF THE PLATE V41TH 3/16" HE[ 67HT BLA GK TEXT ON CLEAR 5ELF-ADHE51VE TAPE. FM] r 5H PE— c� -- 1 0 EXAM 4 A1-5,77 Flo, - PEDIATRIC, E2�AM �3 EX15TINC7 3 EX15T K105 5TOR PLAY AREA TOILET I (Ex) E-: (Fz� EX15TIN& PEDIATRIC �PEDIATRIC VITAL�2 EXAM I EXAM 2 EX15TIN6 I C, \fF=, PEDIATRIC (EX) (EX) HAITI c-;-fj I A IC OF (EX) Fj OF1 f=l (Ex) (EX) 61FI qr 1� im r, NOTES REGEPTAGLE, COAX, AND DATA OUTLETS, FOR TV AT 12" AFF. VERIFY ALL HIRIN& DEVICES AND CIRWTRY TO REMAIN. MAINTAIN CIRCUIT E EXACT LOCATION HITH OHNER PRIOR TO ROU&H-IN. CONTINUITY THROU67HOUT DEMOLITION AND NEH CONSTRUCTION. y Q COPPER OROUND BAR: FIELD VERIFY EX15TIN6 DEVICE LOCATION5 ARE NOT IN CONFLICT HITH NEA 4"H x 1/2" THICK x 12" LON& HITH A MINIMUM OF,5 HOLES FOR CONDUCTORS MILLAORK AND SINK, AND MODIFY IF REGUIRED. UP TO 1/05TRANDED. &ROUND BAR SHALL BE MOUNTED ON STANDOFFS AT 15" A.F.F. 6,ROUND BAR SHALL BE FURN15HED, INSTALLED, AND HIRED BY RECONNECT TO EX15TIN6 CIRCUIT 5ERVINC7 TH15 ROOM/AREA. FIELD VERIFY ELECTRICAL CONTRACTOR. ROUTE 1/0 STRANDED CONDUCTOR IN 1-1/4" CIRCUIT FROM PANEL INDICATED. CONDUIT TO SERVICE OROUND. CONNECT TO EXISTIN6 CiRGUIT INDICATED HITH MATCHINO CONDUIT AND PROVIDE POHER AND CONNECTION FOR NEH RECIRC. PUMP AT EX15TINO P41RE 51ZE5. HATER LOCATED ABOVE CEILIN6. FIELD VERIF'rEXAOT LOCATION. 2000NDUIT HITH PULL HIRE FOR DENTAL CABLIN67. COORDINATE HITH REGEPTAGLE CIRCUITS SHALL BE PROTEGTEP BY NEH C-+I--rYPE GIRGUIT DENTAL EWIPMENT SUPPLIER PRIOR TO ROU(5H-IN. BREAKERS. EX15TINC-7 TELE/DATA 5ER\/I6E PROVIDER/TENANT5ERVIGE EQUIPMENT TO REFER TO HIRIN& DETAII-5 ON SHEET E5. REMAIN. RECEPTACLE MOUNTED BELOH COOLER HOU51NO. COORDINATE HITH EX15TINO 5ERVIGE EGIUIPMENT TO BE MODIFIED. SEE R15ER DIA67RAM FOR PLUMBINO CONTRACTOR PRIOR TO ROU&H-IN. DETAILS. EX15TIN6 TELEPHONE BOARD IN TH15 ROOM TO REMAIN. ROUTE THO 2-1/2" CONDUITS HITH PULL HIRES TO EX15TINO ELEGTP-16 ROOM Ilb. PROVIDE POHER AND C-ONNECTION TO DENTAL EGUIPMENT GON50LE PER EGUIPMENT SUPPLIER'S INSTRUCTION. COORDINATE HITH SUPPLIER/ INSTALLER PRIOR TO ROU&H-IN. ROUTE HOMERUN IN PLUME31NO TRENCH, UP HALL, AND THROU67H GEILIN& SPACE TO PANEL. PROVIDE CONDUIT 5TUB-UP HITH FLEX HHIP AND OUADRAPLEX RECEPTACLE (HITH BOX AND COVER) TO BE LOCATED IN UTIL17Y AREA AT FOOT OF DENTAL CHAIR. COORDINATE EXACT LOCATIONS AND REQUIREMENTS HITH CHAIR SUPPLIER/ INSTALLER PRIOR TO ROUOH-IN. 5HUNT-TRIP BUTTON HITH PROTECTIVE COVER MOUNTED AT (50" A.F.F. PU5H BUTTON5HALL 13E MAINTAINED CONTAGT, PUSH TO TRIP, PULL TO RESET. PROVIDE PERMANENT LABEL "DENTAL SYSTEMS EMER&ENCY OFF" REFER TO PANEL '01'FORSHUNT-TRIP BREAKER5 TO 13E ACTIVATED BY TH15 PU5H BUTTON. BUILDINO MAIN 5ERVICE EGVIPMENT. REFER TO POHER R15ER DIA6,RAM. LONVOLTAC-7E JUNCTION BOX HITH I" CONDUIT TO AE30VE C-,EILIN5. REFER TO DENTAL EOUIPMENT VENDOR'5 PLAN5 FOR ADDITIONAL INFORMATION. X-RAY OPERATOR STATION. REFER TO DENTAL EGUIPMENT VENDOR'5 PLANS FOR ALL INSTALLATION REGgJIREMENT5. 50 AMP, 24OV, 2-POLE, NEMA 1, DI5CONNECT 5NITCH FUSED AT 20 AMP5 HITH RK-5 FUSES, INSTALL GLA55'R'REJEGTION CLli=�5. MAKE FINAL GONNEGTION TO VACUIJM PUMP. 30 AMP, 24OV, 2-POLE, NEMA 1, DISCONNECT 5HITGH FUSED AT 30 AMPS HITH RK-5 FUSES, INSTALL GLAS5'R'REJEGTION CLIPS. MAKE FINAL CONNECTION TO AIR GOMPRE550R. COORDINATE MOUNTIN6 HEI&HT5 AND LOCATIONS OF ALL NEH RECEPTACLES IN5TERILIZATION 115 HITH DENTAL EGUIPMENT SUPPLIER. REFER TO MIDMARK SHOP DRAHIN& ELEVATIONS FOR DIMEN51ON5. PONER PLAN 5CALE: 3/16" = 1'-0" NORTH CREHAYEB & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS 3702 AZEELE ST. OCTS (8f3) 876-1415 TAMPA, FL 33609 www.chehayeb.com LIC. #49521 SOUHEIL S. CHEHAYEB CERT. #7340 21-117 Issue Date 09-03-21 L) 00 40 r cl, < LL z T- Z a LL C cc D 00 0 6 0-0 -3 c: 0 0 U) (D > (D >1 0 (D (D N 010-0 4-4 (D (D 0 4-- 0 c: E �= 0 4-a Job Number 2008 Revisions Z� Z� I Z� I POWER PLAN E N 8�?., No, 49521 ST E OF T s 4 I H T I N 0 179 x T U R E A MOUNTINO DETAIL JUNCTION BOX INSTALLED ABOVE CEILINC-7 - AVOID TYPICAL CONDUIT CONCEALED CABLE HOI E5, A/C DUCT, ETC. AE30VE SUSPENDED CEILIN& TO NEXT JUNCTION BOX OR HOMERUNA Nip) �v CEILINC7 SUPPORT FIXTURE INDEPENDENTLY FROM STRUCTURE ZOL-rl%%.�r� �w� I "r-N � FIXTURE CAN BE SHIFTED ONE COMPLETE TILE IN ANY DIRECTION. NIQM2-2 1. PROVIDE #12 &REEN C-AROUND PqIRE IN FLEXIBLE CONDUIT HITH BRANCH CIRCUIT PqIRIN6 AND BOND TO OUTLET E30X AND FIXn)RE HOU51NC-7. 2. 5ECU'RELY FASTEN FIXTURE TO CEILINO FRAMIN6 MEMBERS PqITH FOUR (4) T-BAR CLIPS PER FIXTURE. ATTACH TO SUSPENDED CEILIN& &RID ONLY AS APPROVED BY AUTHORITY HAVINc-7 JURISDICTION. 3. CONTRACTOR TO IDENTIFY LI&HT FIXTURE5UPPORT P4IRE5 AS APPROVED BY LOCAL AUTHORITY HAVINC-7 JURISDICTION. 4. THE DETAIL ABOVE 15 NOT INTENDED TO 5HOH ROOFSTRUCTURE TYPE, BUT TO DEMONSTRATE THAT FIXTURE 5HALL BE SUPPORTED FROM STRUCTURE INDEPENDENT OF THE CEILIN& ORI05Y5TEM, PLUS 50ME ADDITIONAL REQUIREMENTS AS 5HOV4N IN THE DETAIL. 5. CONTRACTOR SHALL VERIFY EXACT MOUNTIN& REQUIREMENTS P41TH THE LOCAL AUTHORITY HAVIN& JURISDICTION PRIOR TO START OF CONSTRUCTION AND PROVIDE ACCORDIN&I-Y. L14A 01 HIRINO DETAILS M r 60/2/40 E 30/2/30 D.E. 240V 0 240V NEV4 NEH HP H (2&.4 MCA) L AHU-5 M0,60, HP-5 A SEE PANEL SEE PAWL N SCHEDULE SCHEDULE D-15,17 -o T 30/2/30 D.E. 60/2/40 D.E. A NEH 24OV NEH 240\/ HP L AHU-6 HP-(q (2a.4 MCA). (25.71 MCA). SEE PANEL SEE PANEL E SCHEDULE SCHEDULE a P-12,14 D-20,22 U I NOTES-. p 1. VERIFY NAMEPLATE R.ATIN65, LOCATIONS, AND POINT OF POkER CONNECTIONS H PRIOR TO ROUC-M-IN. E 2. DO NOT LOCATE DISCONNECT 5NmrHE-5 OVER UNIT ArrE-s5 PANEL5. N 3. PROVIDE A 3/4' EMPTY CONDUIT THROU&H iNACcE551BLE LOCATIONS (Le., T HALLS, UNDER SLAB) FOR CONTROL HIRIN67. COORDINATE HITH MECH. PLANS. 4. EQUIP. REQUIREMENTS ARE FOR MANUFACTURER AND MODEL NUMBER LISTED ON MECH. PLANS. THE MECH. CONTRACTOR SHALL BEAR ANY ADDITIONAL C05T5 INCURRED IF ALTERNATE EQUIPMENT 15 PROVIDED. 5. VERIFY ACTUAL EQUIPMENT NAMEPLATE MAXIMUM OVERCaRRENT PROTECTION RATIN& AND ADJUST FU5E SIZES ACCORVIN C-71-Y. INSTALL 'RK-5' TYPE FUSES AND CLA55'WREJECTION CLIPS. HIA DEVIGE MOUNTINO HE16HT DETAIL T y p I C., A EXIT 12" MAX. TO CENTERT L Ll 67HT %4ITCH OR DIMMM-\ KALL MOUNTED TELEPHONE IRECEPTACLE 4 INCHE-5Tr-- c3i 0 L�j RECEPTACLE TELE/DATA 49� JACK- 4e� TOP OF COUNTER INCHES INCHES BACKSPLA5H T I& INCHES FLOOR N05CALE NOTE-5--i 1. ALL DIMEN51ON5 ARE TO CENTER LINE OF DEVICE, UNLE55 OTHE"5E NOTED. 2. DEVICE55HOk4N IN TH15 DETAIL ARE FOR MOUNTINe HEI 67HT REFERENCE ONLY AND NOT FOR LOCATION5.5EE DRAKNC-6 FOR ACTUAL LOCATIONS, FOR EXAMPLE, ADJACENT DEVICES 514ALL BE NO MORE THAN 2" APART. 3. k4HERE EXIT Ll 6,HT 15 MOUNTED ABOVE A DOUBLE DOOR, CENTER EXIT LI &HT BETP4EEN DOORS. P21A CHEHAYEB & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS 3702 AZEELE ST. (813) 876-1415 TAMPA, FL 33609 www.chehayeb.com LIC. #49521 SOUHEIL S. CHEHAYEB CERT. #7340 21-117 issue Date 09-03-21 C3 c 00 to M (0 -j < U. Z p -J Z C. LL :) E C coo 6 c- LL c: 0 - 0 L- W (D > W >1 0 CL c- W N ry x_- (D 4-4 c: E E 0 -0 4-j c: a) Job Number 2008 Revisions Z� Z� A ELECTRICAL DETAILS No� 49521 STA-fE No. OROUNDINO DETAIL E NOTICE: SERVICE THE INFORMATION SHOHN IN EOUIPMENT THIS DETAIL SHALL BE CONSIDERED AS THE MINIMUM REQUIREMENTS, AND SHALL NOT EOUIPMENT BE REDUCED V41THOUT HRITTEN NEUTR.AL BU5 OROUND BU5 APPROVAL FROM THE �il #4 CU. 6ND. ENOINEER OF RECORD. ml BUILDIN& FULL SIZE OROUND E STEEL CONDUCTOR. SEE NOTE #513ELOH 20'-0" EXOTHERMIC HELD (TIrp) E MINIMUM I �-- METALLIC UNDER &ROUND (MINIMI)M 10'-0" LON&) FULL SIZE HATER PIPE - BOND HITHIN 51-0" AFTER ENTERIN& BUILDIN& &ROUND U CONDUCTOR ELECTRODE ENCASED IN I MIN. 2" OF CONCRETE p 3/4" x 20'COPPER (SEE NOTE #4) CLAD &ROUND RODS. FULL 51 ZE C-ROUND m CONDUCTOR E NOTES.. N 1. FULL51ZE C-ROUND MEANS THAT 6ROUND CONDUCTOR51ZE SHALL BE A55HOHN ON SERVICE T EGIUIPMENT ON THE POHER R15ER DIA65RAM. 2. AFTER &ROUNDIW95Y5TEM 15 INSTALLED, &ROUND RE515TANGE SHALL 13E MEASURED, TO A55URE THAT &ROUND VALUE OF 10 OHM MAXIMUM RESISTANCE IS ACHIEVED. IF NOT, ADDITIONAL &ROUNDIN& SHALL BE PROVIDED TO MEET THE SPECIFIED VALUE. 3. ALL CONNECTIONS TO OROUND RODS SHALL BE EXOTHERMIC HELD CONNECTIONS. 4. &ROUND CONDUCTOR SHALL BE LOCATED HITHIN OR NEAR BOTTOM OF CONCRETE FOUNDATION OR FOOTINe THAT 15 IN DIRECT CONTACT HITH THE EARTH, AND SHALL CONSIST OF AT LEAST 20 FEET OF ONE OR MORE STEEL REINFORGIN& BARS OR ROM OF NOT LE55 THAN 1/2 INCH DIAMETER, OR OF AT LEAST 20 FEET OF BARE C-OPPER CONDUCTOR. 5. INTER 5Y5TEM f3ONr,>INE7 TERMINATION HITH A MINIMUM OF THREE TERMINATION REWIRED, IN COMPLIANCE HITH N.E.C. 2014 EDITION ARTICLE 250.c[4. EXTERIOR RATED, EGVAL TO ARLIN6TON #C-555250. P14A PONER RISER DIAORAM, NO SCALE NOTIGE CONTRACTORSHALL BE RESPONSIBLE FOR PROVIDIN67 ARC FLASH LABELS AS REGUIRED BY NFPA 10 (NEC) 110.16, AND PERSONAL PROTE6TIVE EOUIPMENT (PFE) RATIN& PLAGARD5 PER NFPA7OE FOR ALL 5HITCH&EAR. N41A 01 INSTALLATION DIAORAM 5 5UR67E- SUPPRESSOR U BREAKER. 5W 67E SUPPRESSOR E PANEL TYPICAL —1--i U p 5UR0E 5UPPRE55OR HIRINO NOTES: p 1. AHERE A WRC-:,E WPPRE55OR 15 CONNECTED TO A BREAKER IN A PANEL130ARD OR A D15MBUTION PANELBOARD THE LEAD LENOTH FROM THE BREAKER TO THE SUPPRESSOR SHALL BE KEPT TO A MINIMUM. AND THE 5UPPRE55OR SHALL BE MOUNT"ED ON THE 5AME51DE AS THE BREAKER 5ERVIN6 THAT SUPPRESSOR. ALL BREAKL9;Z5 FEEDINO 5UPPRE55ION UNITS SHALL BE PROVIDED NITH LOCK ON HANDLE. 2. IN NO CA5E5HALL A DISTANCE BETHEEN BREAKER IN PANEL POHERIN& 5UR(9E 5()PPRE55ER UNIT AND THE 5UROE SUPPRESSOR UNIT BE MORE THAN 12". P4qA FX15TIN(9 TO REMAIN EXI5TIN(5 TO BE REMOVED — — — — 1121429"A rel Nwlwlr_�*Z MIA NOTES K (DEX15TIN C-7 120/24OV, I -PH, PAD MOUNTED, UTILITY TRANSFORMER TO E REMAIN. FIELD VERIFY EXACT LOCATION AND ANY UPORADE REQUIRED PRIOR TO 510 AND/ OR ROUC7H-IN, HITH UTILITY REP, AND Y PROVIDE ACCORDINOLY. EX15TINO UNDER&ROUND SECONDARIES TO BE COMPLETELY REMOVED. EX15TIN65 METERS AND TENANT MAIN 5HITCHES TO BE COMPLETELY REMOVED. THREE SETS OF 3" CONDUIT HITH 3 #500 MCM CU IN EACH (APPROX. 125'-0") UNDER &ROUND SECONDARIES. C.T. METER AND C.T. GA13INET PER UTILITY CO., COORDINATE AND PROVIDE AS REGUIRED. PROVIDE 1-1/2" CONDUIT BETHEEN METER AT 6.T. CABJNET FOR UTILITY 60. USE. #3/0 CU5ERVIGE &ROUND. REFER TO 6A;ZOUl,0IN67 DETAIL ON THIS SHEET. THREE 3" CONDUITS HITH 3 #500 MCM CU, 1 #3/0 DONDIN& JUMPER IN EACH. SURC-E WPPRE55OR EGUAL TO WROE SUPPRESSION, INC, #5TMV50-i5I-X (NEMA 3R). SEE HIRINC7 DETAIL ON THIS SHEET. 5UR&E SUPPRESSOR EGUAL TO SOROE5UPPRE55ION, INC. #5TMD24-151-P (FLUSH MOUNT).5EE HIRIN6 DETAIL ON THIS5HEET. REFER TO PANEL 'M'56HEDULE FOR CONDUIT AND HIRE51ZE5. (D LlCvHTlt4& CONTROL PANEL. REFER TO HIRIN& DETAIL ON5HEET E3 FOR ADDITIONAL INFORMATION. INTER-5Y5TEM BONDINe TERMINATION BAR, REFER TO SERVICE EGUIPMENT 67ROUNDIN67DETAIL ON TH55HEET. EXTERIOR RATED. EX15TIN& PANEL FEEDER TO REMAIN. FIELD VERIFY CONDUCTOR 51ZE5 AND LEN&TH PRIOR TO BID. EX15TIN& 015CONNECT SNITCH514ALL REMAIN. PROVIDE NEH FU5E5, EGUAL TO EX15TINe, FIELD VERIFY PRIOR T05TART OF HORK. 5UR&E SUPPRESSOR EGUAL TO 5UR&E SUPPRESSION, INC. 05TM024-151. SEE HIRIN& DETAIL ON TH15 SHEET. Ulb VERIFY THAT THE EX15TINCv FEEDER 15 3 #3/0 CU. 4 1 #ro E.O. IN 2" CONDUIT MINIMUM. ELSE, PROVIDE NEN. VERIFY THAT THE EX15TIN6 FEEDER 15 3 #250 MOM CU. 4 1 #4 E.O. IN 2-1/2" CONDUIT MINIMUM. ELSE, PROVIDE NEH. N4A CHEHAYEB & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS 3702 AZEELE ST. (8f3) 876—f415 TAMPA, FL 33609 www.chehayeb.com LIC, #49521 SOUHEIL S. CHEHAYEB CERT #7340 21-117 Issue Date 09-03-21 d c: A., 100 < LL_ < Z q _j Z a LL :) E C () M �O �- (0 (D co 0 cf) — co 0 6 c: CU _0 LL c: 0 0 4_4 > ell >N 0 dw c- L) N r- (D 4_4 CU o 4— >1 0 -1-a _0 E E E 0 _0 co Revisions Z� A A MMM19 i 5ERVIGE ENTRANGE RATED issue Date 09-03-21 MANUFACTURER SQUARE "D' N EW PANEL: PANEL TYPE-- L_ L INE FED FROM.' UTILITY 1ZO/240 VOLTS Zi?K INTERRUPTING CkPACITY (AIC) RA TED: SERIES - FULL X M I PHA SE 3 MOUNTING� LOCATIOW EXTERIOR WIREISOLH) NEUTRAL AMPERE BUS FLUSH SURfACE X WSECIA U NEMA 3H ENCLOSURE 800 kMPERE MAIN 800 MAIN TYPE BREAKER No. KVA ED WIRE GND COND Description BRKR A 8 BRKR Description WIRE GND COND LD KVA Nod 1 22,2 3#250 1#4 2-112* PANEL 'A' fRM 250 34.6 ZIJ 2S.0 -0' 0.0 1 010 --- -- - ------ --- 33. 1 0 21.3 2Z�6 -1 k -- - -- I 0'0� 250 iRm PANEL 'C' 3#310 146 2-1/2' 1215 2 TRP 250 200 JD TRP TYPI 20�5 TYP JD 12.6 3 L 3#3JO 2#6 2-112- PANEL*Al' FRm TRP 2SO 200 250 Film PANEL 'D' 3#310 1 #6 2-112' 133 4 I 200 TRIP TYP ID 11) TYP 5 I I �O 3#310 1 #6 2-112- PANEL "B" FRM TRP 250 200 250 z 5V FRM PANEL '91' 3#310 2#6 2-112' 14,0 6 200 TRP TYP JD 10 TYP l31.S 7 0'0 SPARE FRM FRP ISO 100 - FRM SPACE ONLY - IRP 0.0 TYP HD - TYP --+0-. Ud 9 0,0 3#10 11#10 3/4' SURGE SUPPRESSOR FRM ISO VHM SPACE ONLY 0.0 40 T R P 30 - TRPJ TYPI HD - IT YP] 0�0 LEGEND/NOCES,, 20(L) - PROV IDE HA NDLF LOCKING DEV ICE FOR THIS BREA KER KVA SUB T OTALS-1 84.3 1 1 1 79.9 1 TOTAL KVA- (OTAL AMPERES: 164A i�� TENANT 5 11 1 W�m LEGENDINOIES- I CONNECTED LOAD KVA,. 4Z6 20(L) � PROVIDE HANDLE LOCKIN6 D(VICE FOR'FHJS BREAKER KVA SUB TOTALS, Z?.?. 20� 5 STD. DEMAND FACTOR (1,0); 39A + LTG DEMAND (1.25 LTG)� `kO 0.0 0.0 KITCHEN DEMAND: 0.0 TOTAL DEMAND KVA, 414 GRANDTOIAL� ?2�2 20.5 DEMAND AMPERES: 180.43 KITCMEN MULTU'LlEft PER NEC 2017 TABLE 22M 56 MA NUFA CTURER. SQUARE 'D' PANEL TYPE' LOAD CENTER 22K INTERRUPTING CAPACITY (AIC) LOOk TION- SUITE 37918 NEW PANEL: Al it-[) FROM: PANEL 'M' 1201 240 VOLTS I PHASE 4 WIRF/SOLID NEUTRAL AMPERE BUS RATED� SERIES: X FULL MOUNTING: FLUSH X SURFACE SPECIAL- ISOLATED GROUND BAR 225 AMPERE MA IN ?-?1 5 MAIN TYPE LUGS . . . . . .......... . ...... M ARE ME IBM a MIME 10 REFRIGERATOR REFRIGERATOR N ON 01 now El mom WEE 0 SPACE ONLY BE NE M BE 0 WIN FEE EN ME 0 NO 0 BE 0 SPAC E 0 N L Y NE ROM SPACE ONLY M HIM ... ..... ... ... ........... .......... . . ...... . ...... 0 M1 M LEGENDINOTES: I WNWAAt.0 WAIJ UA� I bA 20(L) - PROV IDE HA NOLL LOCKING DEV ICE FOR THIS RHEA KEN KVA SUB 10, IA I S' 8iU SIO. DEMAND MCIOR (1.0)� 115�:4 + LTG DEMAND (125 LTG), 0-0 0.0 + KITCHEN DEMAND. 0.0 TOTAL DEMAND KVA.* 16,4 GRANDTOTAL: &4 8.0 DEMA NO A WERE 5: 68,1 KITCHEN MULTIPLIER PER NEC 2017 TABLE 220�56 MAN UFA (TO RE ft SIEM ENS LOCATION� SUITE 37920 SPECIAL EXISTING PANEL: B PANEL TYPL LOAD CENT ER FED FROM: PANEL 'M' 1201 240 VOLTS I PHASE 3 WIREISOLID NEUTRAL AMPERE BUS 200 AMPERE MAIN 200 (EX) INTERRUPTING CAPACITY (At() RATER SERIES: - FULL: MOUNTIN(t FLUSH X SURFACE - MAIN TYPE LUGS No� KVA NOT E WIRE GND COND Description ED BRK A A R BRK ED Desfiripflon WIRE MR COND NOTE KVA Nci� I 0�8 2#12 1#12 3 t4' REC-OFFICE R 20 ---0 1.9 53 0.8 t.0 0'0 0�0 D 0.0 1'2 5.3 71 0�8 1_018 r�o - O�O 20 L 11-NANT SIGN 2912 1 #12 112" R4 1.2 2 - 3 CIA - 2#12 HE( -OFFICE R 20 20 L LIGHT ING 2#12 1#12 112' - 0.4 4 REC-OFFICE R 20 20 1. L14GHT ING ?.#1?. 1#'12 112, R'3 0.9 6 7 OA EX EX C x RECEPTACLES M 20 50 A AHU-3 EX Ex Ex 9 0,8 EX EX EX RECEPTACLES M 20 [- A - 4.5 10 11 0�8 EX EX EX RECEPTACLES M 20 40 x HP-3 Ex EX EX - 3A 12 13 O�8 EX EX EX RECEPI ACLES M 20 x 3.1 14 15 0'6 ?*l? 1#1? 1 w REC-EXAM M 20 ?0 R REC-OUTSIDE Ex EX Ex 0.2 16 t7l 0'0 SPARE 20 20 M (EXIST. CIRCUIT) EX EX EX 1.0 18 191 0.0 SPACE ONLY - - m 1 I �o 20 211 O.o SPACE ONLY SPACE ONI Y 0�0 Z2 23 0.0 SPACE ONLY SPACE ONLY 1 0.0 Z41 2 15 ob SPACE ONLY SPACE ONLY 0.0 26 27 010 NB 3ftlo 1410 3/4' SURGE SUPPRESSOR 30(L) SPACE ONLY 010 28 Eq. - 0,0 SPACE ONLY 0�0 30 LF%ENOINOTES� I CONNECTED LOAD KVA.- 20� 1 20(L) = PROVIDE HANDLE LDCKING DEVICE FOR THIS BREAKER KVA SUR TOTALS. I 1=0 911 STD. DEMAND FACTOR (1�0)-. LL6 LTG DEMAND (125 LIG). 3.1 KITCHEN DEMANCI, k 0.0 TOTAL DEMAND KVA: ?0. GRA NO TA To Lit 9.1 DEMAND AMIi 86A KI ICHEN MULTIPLIf R PER NEC 2017 TABLE 2ZO�56 MANUFACTURER SIEMENS EXISTING PANEL: C LOCA I`ION- SUIT E 37922 SPECIAL. PANEL TYPE LOAD CENTER FED FROM: PANEL. 'M' 1201240 VOLTS I P14ASE 3 WIREISOLIDNEUTRAL A WERE BUS 200 AMPERE MA IN 200 (EX) INfERRUPTING CAPACITY (AIC) MILD. SERIES. - FULL MOUNTING� RUSH Y SURFACE MAIN TYPE LUGS RECEPTACLES BMW Mo M M M rum El RECEPTACLES WATER HEATER .. ..... ... ff RECEPTACLES RECEPTACLES RECEPTACLES SPARE "PARE ON RE(EP1ACLES M IBM RECE? I A L ES M SURGE SUPPR SSOR iLY LEGENDINOTES: CONNECTED LOAD XVA; 25,,0 ZO(L) = PROVIDE HANDLE LOCKING DEVICE FOR THIS BREAKER KVA SUB TOTA LS� 12.5 12.6 STR DEMAND FACTOR (1.0), 232 + LTG DEMAND (1.25 LTG)� �3 0,0 O�O 4 KITCHEN DEMAND, ILO TO Uk L DENA ND KVA 25's GRAND , TOTAL 12�5 12.6 DEMANDAMPERES� 106.0 KITCHEN MULTIPLIER PER NEC 2017 [ABLE 2201,56 MW Category Connected KVA Demand Factor Demand KVA Rem arks Lighting 11.2 1.25 14.0 Receptacles (First iOkw) 10.0 1-0 10.0 Receptacles (Remaining) 12.4 0.5 &2 Misc. Loads 38.8 1.0 38-8 HVAC + 49.6 1.0 49.6 Kitchen Loads++ 0.0 1.00 0.0 Water Heater 13.5 1.0 13.5 Refrigeration 0�0 1.0 0.0 Show Window - Load calculation per NEC 220.14(G)(2) 0.0 1�25 0.0 0 FT OF SHOW WINDOW AT 200VA I LF Dental Equipment 2Z6 1.0 22.6 User Defined Load 0.0 1.0 0.0 Sub -total 154J 0 LESS SHOW WINDOW LOAD IN PANELS 25% Largest Motor 1.3 Total KVA* Tota I AMPS: 156,.0 24o Voltage hase �Service + Heating and Cooling loads are non -concurrent loads. ++ Kitchen multiplier per NEC 2017 Table 220.56. 1 SERVICE SIZE IS 800 AMPS AT 120/240V, 1-PHASE I MA N UFA QU R E I L' SIEMENS LOCA TION: SUITE 37924 SPECIAL, EXISTING PANEL: D PANELTYPE. LOADCENJER FED FROft PANEL 'M' 1201240 VOLIS I PHASE 3 WIREISOLID NEUTRAL AMPERE BUS 200 AMPERE MAIN 200 (EX) INTERRUPTING CAPACITY (AIC) RATED; SERIES, FULL' MOUNTINQ FUJSJJ X SURFA CE - MAIN TYPE LUGS M mm�=AMM . . ............ ............ .. 0 =0101 No . . . . ...... .... .. RE( -PROVIDERS REC - COMM. SERV. MEN wool =1171 WIN IBM AIM 0 WATER HEATER IIP-6 mom mom LEUNDINOIES, CONNECTED LOAD KVA: 26� 5 201 = PROV IDE HA NOLL LOCKI N G DEV ICE FOR 4 It IS BRE A KIR KVA SUB TOTALS: 13.3 13.3 Slft DEMA NO 1"A CTOR (1.0): 2Z8 + 11(-, DEMA N D (I � 2 5 LTG): 4,6 OLD 0.0 + K11Cf1LN DEMAND: 0.0 TOTAL DEMAND KVA: 244 GRA N D TOTA L.- 113 13.3 DEMA NO A MPFRES� 1143 ]KITCHEN MULTIPLIER PER NEC 2017 TABLE 220,56 MANUFACTURER SQUARE "0' PANELTYPE- LOADCENfFR FED FROMz PANEL. *M' IOCA TION,, SUITE 37924 SPEOAU ISOLATED GROUND BAR NEW PANEL: D1 1ZO/ 240 VOLTS I PHASE 4 WIREfSOLID NEUTRAL AMPERE BUS INTERRUPTINGG&PACTY(AIC) RATED, SERIES-, X FULU MOUNTING; FLUSH SURFA CE X 225 AMPERE MAIN 2?5 MAIN TYPE LUGS WATER COOLER 01 EW�M= i MICROWAVE ni DENTAL CHAIR i F_ -REC�00'-ERAT-ORY DOE WEE DENTA L CHAIR Mw�jkxlj M - FEE MIM! 1EM ME MEMI 1010 M BE 0M 100 0 MIEE=1VA 1EM . __ VACUUM PUMP 1M NOME MEE IE1 MIM 00101=0 1010 mm"bWAMMEE ME FEE BE 1010 ME 11001 in a N WE BE MEW LEGENDINOTES: I CONNECTED LOAD KVA; 27.5 ?OCL) �� PROVIDE HANDLE LOCKING DEVICE, FOR THIS BREAKER KVA SUB TOTALS: 14.0 13�5 5 TD. DEMA ND FACTOR (1.0)� 27�5 + LTG DEMAND (L?5 L%)� ITO 0.0 0-0 4, KITCHEN DEMANDi 0.0 TOTAL DEMAND KVA� �TS &RAND TOTAL 1,LO 13.5 GEMA 14D A WF RE, 5� 114.6 KITCHEN MULTIPLIER PER NEC 2017 TABLE 220.56 PANEL 50HEDULE LE&END 16 15OLATED 6ROUND CIRCUIT 6 F eRtOUND FAULT INTERRUPTER L LOCK -ON 50REH IN HANDLE FREE TRIP. G# CONTAGTOR CONTROLLED N) INDICATE5 CONTAGTOR NUH5ER R# = RELAY CONTROLLED # INVICATE5 RELAY NUME3ER 5T = 5HUNT TRIP TYPE BREAKER EX = EX15TIN(5 CIRCUITRY TO REMAIN. Nf3 = NEN 13REAKER EGUAL TO EX15TIN69. PANEL 5GHEDULE INVI== 5qA PANEL 50HEDULE LOAD COPE5 A,A5 = H\/AC LOAD K# = KITCHEN LOAD5 (1,2 OR 3 CIRCUIT) L L16HTIN67 LOAD M�43 MIEC-ELLANEOUE, LOAD R RECEPTACLE LOAD F3 U5ER 5PECIFIED LOAD HH HATER HEATER UP3 U5ER 5PECIFIED LOAD X EXCLUDED, NON -CONCURRENT LOAD. (NVAC LOAD5 ARE NON-<,ONCURRENT; TOTAL5 BA5EP ON HIC-MER VALUE. CREHAYEB & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS 3702 AZEELE ST. (813) 876-1415 TAMPA, FL 33609 www.chehayeb.com Li C < Z M_j Z 0- U_ :) E C co Ma 0 LL C 0 0 L_ (D 0 CL W N ry (D 0 4-- 7t >1 :3 0 E E M 0 4_4 2: a) E co Job Number 2008 Revisions Z� PANEL SCHEDULES o.4951 STATE ­J11NIFT 7- No. LIC. #49521 SOUHEIL S. CHEHAYEB CERT. #7340 21-117 DI\ASION 16 - ELECTRICAL Issue Date 09-03-21 SEC11ON 16010 - GENERAL PROVISIONS 1. GENERAL 1�01 The following are minimum requirements and shall govern, except that building laws and/or drawings shall govern when their requirements are in excess thereof. 2. DRAWINGS AND SPECIFICATIONS 2.01 The architectural, mechanical, electrical and equipment drawings and specifications are hereby incorporated into and become a part of this Division. This Contractor shall examine all such drawings and specifications and become thoroughly familiar with provisions contained herein and the submission of his bid shall be construed as indicating such knowledge. 2�02 Electrical drawings are diagrammatic and ore intended to show the approximate locations of equipment and piping. Dimensions given on the plans shall be verified in the field. Drawings may not be scaled to obtain exact dimensions. 2.03 The exact locations of apparatus, fixtures, equipment and conduits shall be ascertained from the Owner's representative in the field, and the work shall be laid out accordingly. Should the Contractor foil to ascertain such locations, the work shall be changed at his own expense when so ordered by the Owner. The Owner reserves the right to make minor changes in the location of conduit and equipment up to the time of installation, without additional cost. 2.04 The electrical drawings and specifications are intended to supplement each other and any material or labor called for in one shall be furnished and supplied even though not specifically mentioned in both. Labor and/or materials neither shown nor specified, but necessary for the completion and proper functioning of the system, shall be provided by this Contractor. 2�05 The work required under these specifications includes all labor, materials, equipment and services necessary to provide lighting and power systems, service entrances, motor controls and connections, branch circuiting, feeders, panels, fixtures, wiring devices, and other items shown on the plans or specified. 2.06 When the specification of on item is not identified with a particular area, the item shall pertain to all areas. 2.07 This Contractor shall furnish such labor and materials as hereinafter specified and as required to complete all electrical connections in accordance with the manufacturer's requirements for all mechanical equipment and Owner's equipment as shown and/or specified, 3. EXAMINATION OF SITE 3.01 Bidder is to visit the site and familiarize himself with existing conditions and satisfy himself as to the nature and scope of work. The submission of a bid will be evidence that such an examination has been made. Later claims for labor, equipment of materials required, or for difficulties encountered which could have been foreseen had (in examination been made, will not be allowed. 4. DEFINITIONS 4.01 "Install" shall mean to place, fix in position, secure, anchor, wire, etc., including necessary appurtenances and labor so that equipment or installation will function as specified and intended. 4.02 "Furnish" shall mean to purchase and supply equipment or components. 4.03 "Provide" shall mean to "furnish and install". 4.04 "or approved equal" shall mean equal in type, design, quality, style, color, etc., as determined by the Engineer/Architect, 5. INTERFERENCES 5.01 It shall be the duty of this Contractor to report any interferences between his work and that of any other Contractor to the Owner or Architect as soon as they are discovered. The Owner or Architect will determine which equipment shall be relocated regardless of which was first installed, and his decision shall be final. 6. MATERIALS AND WORKMANSHIP 6.01 All work shall be installed in a practical and workmanlike manner by competent workmen, skilled in their branch of the trade. 6.02 Unless otherwise specified or indicated on the drawings, all materials shall be new and free from defects and shall be the best of their several kinds. 6.03 All material and equipment shall meet or exceed standards specified by UL, NEMA, ANSI and IEEE wherever such standards hove been established. 6.04 From time -to -time during the operation and at the completion thereof, this Contractor shall remove all debris and excess materials caused by his work and he shall leave the area of the operation broom clean. 6.05 All electrical equipment and material shall bear the Underwriter's Laboratories label. 7. SUPPORTS 7.01 This Contractor shall furnish and install all angle iron, channel iron, rods, supports or hangers required to install or mount ponelboards, switchboards, or any electrical equipment called for on the plans, in these specifications, or as necessary to mount any piece of electrical equipment, material, or device. Conduit, fixtures, or any electrical devices shall not be supported from steel deck, bridging, ceiling, or ceiling support wires, 8. TEMPORARY CONSTRUCTION POWER AND LIGHTING 8.01 Sufficient temporary power, during construction, for heating, lighting, appliances, or motorized portable equipment shall be provided by the Electrical Contractor. 9. CODES, LAWS, PERMITS AND INSPECTIONS 9.01 Install all work in full accordance with codes, rules and regulations of municipal, city, county, state and public utility, and all other authorities having jurisdiction over the premises. This shall include all requirements of the City Building Code, regulations of the State Department of Industrial Relations, OSHA, ADA (Americans with Disabilities Act), and the requirements of the National Electrical Code, as interpreted by the Local Inspection Division. All these codes, rules, and regulations are hereby incorporated into this specification. 9.02 Comply with specification requirements which are in excess of code requirements and not in conflict with some. 9,03 The Contractor shall secure all permits and certificates of inspection incidental to the work, required by foregoing authorities. All such certificates shall be delivered to the Owner in duplicate, before final payment on contract will be allowed. The Contractor shall pay all fees, charges and other expenses in connection therewith. 10, FIELD CHANGES (AS BUILT DRAWINGS) 10-01 Keep one (1) set of working drawings and shop drawings at the job site for sole purpose of recording all changes made during construction. After completion of the work and before requesting final payment, the above mentioned drawings shall be delivered to the Owner. LABELING AND NAMEPLATES 11�01 Permanently label transformers, switchboards, panelboards, time switches and safety switches indicating equipment or panels and areas which they serve. 11.02 Lighting and appliance panels shall be labeled as shown on drawings. 11.03 Electrical Contractor shall furnish and install identification for pull or junction boxes furnished by him. 11-04- Identify as to use on face of equipment by means of laminated black and white phenolic label with 3/8" letters engraved through black to white. 11.05 Materials A. Nameplates: Engraved three -layer laminated plastic, white letters on a block background. 11.06 Installation A. Degrease and clean surfaces to receive nameplates and tape labels. B. Install nameplates and tape labels parallel to equipment lines. C. Secure nameplates to equipment fronts using screws, rivets or adhesive. Secure nameplates to inside face of recessed ponelboard doors in finished locations. D. Mark every junction or pull box cover plates with the circuit number(s) of all wires contained therein. 11.07 Wire Identification: A. Provide wire markers on each conductor at terminal strips and at final line and load connections. Identify with branch circuit or feeder number of power and lighting circuits, and with control wire number as indicated on equipment manufacturer's shop drawings for control wiring or as drawings indicate. B. All wires shall be color coded. Color code branch circuit wiring as follows: 1. Single Phase System. 120/240V Phase A Black Phase B Red Neutral White Ground Green 2. Switched Wires: Other than colors listed above 3. Travelers Between 3-Way Switches: Purple 4. Insulated Ground: Green with Yellow Stripes 12. GUARANTEE 12.01 In addition to guarantees of equipment by manufacturer of some, this Contractor shall also guarantee equipment provided by him and shall be held for a period of one (1) year to make good any defects in material and workmanship occurring during this period, at his sole expense. This one (1) year period shall start from the date of final acceptance by Owner. 13. SCOPE OF WORK 13,01 Furnish all labor and material necessary to complete the electrical work shown on the drawings, specified herein or required to complete the construction of the building as shown. 13.02 The listing herein of article or material, operation or method, required to be provided and installed by the Contractor (unless noted to be supplied by others) shall be of quality or subject to qualifications as noted. Each operation shall be performed according to standard practice, manufacturer*s instructions, and conditions stated, providing, therefore, all necessary labor, equipment and incidentals. 13.03 The electrical Contractor shall schedule his work to conform to the progress of the other trades and Contractors employed on this project. 1104 The electrical work shall include but is not limited to the following: A. Demolition work as required. B. Complete power and lighting distribution systems including panels, as shown on plans. C. Complete branch circuit wiring system, D. Temporary electric service as required for construction. E. Testing of all electrical equipment. F. Provide and install complete lighting system as shown on plans. 14. MANDATORY SHOP DRAWINGS 14�01 Submit all required electrical shop drawings. 14.02 Shop Drawings shall be submitted for: Switchgear and Ponelboards All Liahtina Fixtures All Wiring bevices Lighting Controls END OF SECTION 16010 SECTION 16100 - BASIC MATERIALS AND METHODS 1. CONDUIT 1.01 All wire shall be run in accordance with the applicable codes in corrosion resistant, rigid, threaded, metal conduit or electrical metallic tubing (E.M.T.), unless otherwise specifically stated herein. A. Conduit below first floor slob, exposed to weather, or underground shall be rigid, threaded, galvanized, heavy wall type. B. Carlon PVC, Type 40 heavy wall conduit with ground wire may be used underground below floor slab or pavement in lieu of rigid, threaded, galvanized conduit. PVC schedule 40 conduit shall not be run in or above first floor slob. PVC conduit shall terminate below floor slab with rigid, threaded metal conduit 1.10 Exposed conduit and conduit in ceiling space shall be run parallel to the building structure. 104 1.11 Conduit system shall conform to all the requirements of the National Electrical Code (N.E.C./N.F,P.A.-70) and local codes. 2. CONDUCTORS 2.05 2.01 Sizes of conductors for feeders are given on the drawings and no wire smaller than #12 gouge shall be used for branch lighting or power circuits. All wiring shall have the U.L label and be of 98% conductivity copper. Aluminum wire or aluminum cable is not acceptable. 2.06 A. The gouge of all wire shall be in accordance with B&S standard. 2.02 All wire and cable for branch lighting or small power circuits shall have "NEC" Type "THHN/THWN" 600-volt insulation. 2.03 Wire and cable above #8 gauge shall be stranded Type "THWN" insulated for 600-volts. 3, 2,04 For special conditions, as provided by the National Electrical Code, Type "R.H.H., A,V.A." or other required insulation 3,01 shall be used. 2.05 Where lighting fixtures are used as raceways, 90 degree C. minimum insulated wire shall be used, 3.02 3, GROUNDING 3.03 3.01 This Contractor shall provide, install and connect a complete system of grounding for all equipment and structures. A good mechanical and electrical connection shall be made with approved grounding connectors. 3.04 3.02 Electrical system and equipment grounds shall comply with the N.E.C. as well as all local and -state codes and regulations. 3,03 Panels, conduit systems, motor frames, lighting fixtures and other equipment that ore part of this installation 4. shall be securely grounded both mechanically and electrically in accordance with all codes. 4.01 3.04 System ground shall not exceed a maximum of ten (10) OHMS resistance. Verify grounding system and add additional grounding as required to meet the above specified value, 3,05 A ground conductor shall be supplied in ALL conduit. It shall be insulated, stranded, annealed copper conductor. 4� TOGGLE SWITCHES AND RECEPTACLES 4.02 4.01 Color of all general purpose switches and receptacles shall be white, Verify color with Interior Designer prior to ordering. 4.02 Acceptable device manufacturers are Hubbell, Leviton, or Pass & Seymour. The basis of design is Leviton. 4.03 4,03 Wall Switches: A. Single poles #1221, double pole #1222 and three (3) way switches #1223 shall be rated 20-ampere, 120/277 volts. B. Switches shall be mounted 4'-0" above finished floor to centerline, 5. 4,04 Hospital grade Duplex receptacles shall be 20-ampere at 125-volts, Leviton Decora catalog #16362-SGW or 5.01 approved equal, Mount at 18" above floor to centedine or as noted on plans. 4.05 Outdoor receptacles shall be weatherproof with spring covers (Leviton #4926 plates). 5. WALL PLATES 5.02 5.01 Unless otherwise noted, all plates in finished areas for wall switches, receptacles and telephone outlets shall be smooth plastic, 5.03 5.02 Ali plates shall have full contact with the wall and boxes. Edges shall be parallel to the finished walls and ceilings. 6. OUTLETS 6. 01 Locations of outlets are shown approximately on the drawings. Contractor shall refer to the shop drawings of the manufacturers of the equipment for the exact location of outlets for fixtures, motors, heaters and their respective control devices. Approximate locations of light fixtures are shown on the drawings. 6.02 Outlet boxes for concealed work shall be pressed steel boxes, galvanized and not less than #12 gouge, except floor boxes which shall be cost iron. Each ceiling outlet designated for a lighting fixture shall have a fixture support secured in place with nuts and bolts. Ceiling boxes shall be four inches (4") round and octagonal with lugs and screws for back plates. Wall outlets shall be four inches (4") square by 1-1/2" deep, single or double cover, except gong boxes of similar depth shall be used at locations requiring more than 2-gong. 6.03 Outlets on the exterior of the building shall be flush weatherproof type. 6.04 All outlets shall be firmly secured in place. Outlets in finished areas shall be flush with finished ceiling or walls. 6.05 All outlet locations in floor shall be verified with Owner's Representative before pouring of concrete floor. 7. BRANCH CIRCUIT WIRING 7.01 The Electrical Contractor shall provide and connect a complete system of panels, conduits, wire fittings, boxes, supports and all other miscellaneous materials required for equipment as indicated on the plans and ready for operation by the Owner. 7.02 All circuits shall be color coded. END OF SECTION 16100 adapter. Conduit above slab shall be metal. SECTION 16400 - ELECTRICAL SERVICE AND DISTRIBUTION C. A ground conductor shall be supplied in all conduits and raceways. The ground conductor shall be copper, and sized per the N.E.C. or as shown on drawing, whichever is more stringent. 1, D. PVC conduit run beneath areas subject to heavy vehicular traffic such as commercial parking areas, drive throu h, etc, shall be concrete encased. This conduit shall comply with NEMA TC-6 and -8 (Power), 1.01 TC-18 (Telephone), ASTM F512 (Concrete Encasement Applications) and UL-651 (Standard). E. PVC conduit used between lighting standards shall be Corlon Type 40 min. and comply with NEMA TC-2, TC-3, and UL-651 (Standard). 1.02 1.02 Conduit and E.M.T. shall be delivered to the building in 10-foot lengths and each length shall have the Underwriter's Laboratories label. 1,03 1.03 Conduit and E.M.T. shall be run concealed in all finished areas of the building. 1.04 E.M.T. connectors and couplers shall be set -screw type made of die-cast as manufactured by Thomas & Betts, 1.04 Steel City, or Appleton. Bends and offsets shall be made with a hickey or power bender without kinking or destroying the smooth bore of the conduit. Paralleled conduits shall run straight and true with offsets uniform 1.05 and symmetrical. Conduit terminals at boxes and cabinets shall be rigidly secured with locknuts and bushings as required by the National Electrical Code and local electrical code. Insulated bushings shall be used on all conduit 1-1/4" trade size and larger. 1.05 Conduit shall be securely fastened in place at no more than 8-foot centers, and hangers, supports or fastenings 2. shall be provided at each condulet, elbow and at the end of each straiqht run terminatinq at a box or cabinet. Horizontal be by -hole kraps device and vertical conduit runs shall supported one malleable or other approved metal 2,01 1.06 Conduit shall not be suspended from the ceiling or ceiling suspension wires, with suitable bolts, expansion shield or beam clamp for mounting to building structure or special brackets. Conduit shall be supported from structural steel or joist and independent of other piping. Do not support conduit from metal roof deck or any other support device of another trade. 2.02 1.07 Armored cable (BX) or nonmetallic sheathed cable (Romex) shall not be used. No aluminum conduit shall be used. 1.08 MC Cable may only be used as described on Sheet El. 1.09 Only short runs of flexible metal conduit not over 6' in length and having a ground conductor, shall be used for terminal connections to motors and also for electrical equipment where it is not practical to make final connection with rigid conduit. Flexible conduit exposed to weather shall be Sealtite. SECONDARY SERVICE Electrical service shall be secondary, as shown on plans with grounded and neutral and secondary metering. Provide all necessary equipment and material and install the service, metering and distribution equipment accordingly. The Electrical Contractor shall be responsible for contacting the power company to secure complete details for the connection to the existing transformer. Electrical Contractor shall provide secondary service cables and conduits from the transformer to main service as indicated on drawings. Site electrical shall be coordinated with local power company by Electrical Contractor. Provide coordination, via the General Contractor, of the Site Electrical Contractor for the final locations, penetrations, and service tie-ins associated with secondary power service entrance conduits. SAFETY SWITCHES General A. Switch shall be type as shown on plan with visible, quick make, quick break blades. Swiches hall be U.L. listed and conform to NEMA Standards. Enclosures A. Steel enclosures with operating handle at side. NEMA 1 for general indoor use, NEMA 3R for general outdoor use and NEMA 4 (stainless steel) where indicated on the drawings, Manufacturer's standard enamel finish. B. The enclosure shall be interlocked with the switch handle such that the enclosure door connot be opened with switch in the "on" position. Switch handle shall be capable of being padlocked in the "off" position. 2.03 Ratings A. Safety switches shall be rated for the continuous current and voltage indicated on the drawings. Where used in conjunction with motor circuits, units shall be horsepower rated for the size motor indicated. B. Switches used as service entrance equipment shall be U.L. listed for use as service quipment. 6. 6.01 6.02 6.03 Poles A. Safety switches shall have the number of poles indicated on the drawings, but not fewer than one (1) pole for each ungrounded conductor to be opened. Fuses A, Where indicated, safety switches shall be fused in each ungrounded leg in accordance with the requirements of the Section entitled "Fuses", Acceptable A. Acceptable manufacturers are General Electric, Cutler -Hammer, Square D, or Seimens. DISTRIBUTION PANELBOARDS (INCLUDING POWER PANELS) Power and distribution panels shall be suitable for voltages indicated on plans and/or riser diagrams. Panels shall be 1-phose, 3-wire, solid neutral, aluminum buss, dead front with lugs in the mains, fuses and heavy-duty switches in branch circuits of size and number indicated on the plans. All lugs shall be U.L. approved CU/Al type. Panels shall be provided with spares and full provisions for future breakers as shown. Panels shall be manufactured as a complete unit by Siemens, Square D, General Electric Company, or Cutler Hammer, not an assembly of parts secured from a supply house. Ponelboards and switches shall be identified for "usage". UGHTING AND APPLIANCE PANELBOARDS Lighting panels shall be dead front type, aluminum buss, with lugs only in the mains and branch circuits as indicated on the drawings. Panels shall have 20 amp single or double pole circuit breakers (capable of interrupting available short circuit current) as required in each branch circuit. Where breakers larger than 20 amperes ore required, the sizes are noted on the drawings, Breakers shall be bolted to bus type, quick -make, quick -break and capable of interchanging 1 or 2-pole units. Multiple units shall be common trip. Provide spare breakers in each panel as shown. All lugs shall be U.L. approved CU/AL type. Electrical Contractor shall arrange circuits as near as possible to circuit numbers on the drawings. At finish of job, Electrical Contractor shall take current reading checks of respective phases. A minimum of circuit connections shall be rearranged to balance (as closely as possible) the load on the panel. Panels shall be enclosed in galvanized steel of code thickness. Cabinets shall be large enough to allow standard size wiring gutters on each side, top and bottom of panels. Mount not over 6*-6" from floor to top of panels, GENERAL (FOR ALL PANELS AND PANELBOARDS) Metal framed card holders with typewritten circuit directory must be provided for each panel. Directory shall be clear and designation shall match identification on equipment. Ponelboards (switchboard, distribution, power panels Grid lighting panels) shall be identified by a label on the switch and/or panel door. Provide engraved laminated phenolic nameplates with 3/8" letters engraved through block to white. All panels, safety switches, starters and in general, all equipment requiring lugs shall be equipped with solderless type U.L. approved lugs. Provide all necessary unistrut, channel, backing and supports to mount switchboard and ponelboards securely in place. FUSES This Contractor shall replace all fuses blown during construction and testing and shall provide a complete set of fuses in all fuse holders, switches, panels and all other devices requiring fuses. Fuses in switchboard and main distribution ponelboards in Electric. room shall be as indicated on plans. A, Provide label in each switch indicating fuse type, ampere rating and interrupting rating. B. Replace all blown fuses up to final acceptance of job. C, Provide and place in a wall mounted metal cabinet in Electrical Room a spare set of three (3) fuses for each size and type fuse used in switchboard in Electrical Room. The cabinet shall be similar to Bussman Spare Fuse Cabinet #SFC, with door, locking handle, internal shelf and fuse stock list. Fuses shall be as specified herein and indicated on drawings. Alternate manufacturer is Littelfuse. In the event the Electrical Contractor wishes to furnish materials other than those specified, a written request, along with complete application data to assure a selectively coordinated system, shall be submitted to the Engineer for evaluation. END OF SECTION SECTION 16500 - LIGHTING 1. LIGHTING FIXTURES 1�01 All fixtures shall be as shown on Fixture Schedules, and approved by owner. 1,02 Unless otherwise indicated, all lighting fixtures shall be furnished and installed by Electrical Contractor as indicated on the Lighting Fixture Schedules, including lamps. d C 4� 00 Ln < U- < Z M _J Z a LL :) E C (D M (0 F- 00 - N CD co CD 0 of moo 6 C: 0 W LL C: 0 - 0 U) IZ > W 0 L_ CL m a) L) N ry 0 -17 0 L) _0 E 0 E < F- -i5 M 0 0 _0 4_4 C_ (3) CIO 1.03 All fixtures shall bear the Underwriter's Laboratories label and shall be installed according to manufacturer's instruction, Job Number 1,04 All fixtures, unless otherwise indicated, shall be new and undamaged. 1.05 Surface -mounted fluorescent fixtures shall be mounted 1-1/2" from ceiling. Mount spacers and supports on 48" 2008 centers with additional support at the end of each row of fixtures. 1,06 This Contractor shall provide and install all necessary support media for all lighting fixtures including structural steel, Revisions angles, rods, etc. In general, fixtures shall be supported in a manner acceptable to the local inspection authorities. All fixtures shall be firmly supported from beams or joists. L 1,07 This Contractor shall support all fixtures from building structural members and NOT from ceiling system. A END OF SECTION 16500 Z� CHEHAYEB & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS 3702 AZEELE ST. (813) 876-1415 TAMPA, FL 33609 wutw.chehayeb.com LIC. #49521 SOUHEIL S. CHEHAYEB CERT. #7340 21-117 __T_ - T - f , i, , ir � 1 1. A 11, 1, 11 1 rn LLj t= 20 pu 5 z :D V) Z 0 a Z z M Lj I= U) 0 0 IL w 0- V) z 0 :3 uo_ I L 0 0 a z uj Z 0 0 Lu Q gs LLJ M F- L! 00 V) =ul UJI On oz 9 uj t x :3 w ou R 9 a- < w Ld w M W V) L� z 00 CL V) 112 w z Ir W 2 5 ;e z w w _j w I _j _j LLj V) (10 w z 0 w C.) x W >-, 0 En 0 Lu V) :3 LLI _j 0 Q 0 6 C.) z W Li = M F- w w iE o Lu Q o z 09 0 ZQ Lj M M _j 66 L) 0, z w M 0� 0 00 z z w 0 W N 0- 0 >- M Z (L < Ld W L) z Uj M (L M 0 0 w L) Cr � Le U) L. 0 La Z M w Lu w Ld = Ld F- w LL 0 0 z 8w 2 M w U Li 2 F 0 LLJ 0 Lj z c) Lj Z cr LL; 6 Z V) LLJ LLI (f) 0 0 80 L) f2 z LLJ z M LLI M ci x => Ig �i Ln LLI IL o V) 0 u) (L z 0 CL V) ui z 0 < z z 0 z 150 5 z. (L GENERAL NOTES PR03ECT NAME & LOCATION GENERAL CONDITIONS 1 , ALL DIMENSIONS AND FIELD CONDITIONS WILL BE VERIFIED BY THE GENERAL CONTRACTOR. 1. SUMMARY OF WORK THE ACCURACY OF THE FIELD MEASUREMENTS IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. DIVISION OF RESPONSIBILITIES TERMINOLOGY: 2. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS WILL COMPLY WITH ALL FEDERAL, "CONTRACTOR": WHERE REFERENCED ON THE DRAWINGS, THE TERM "CONTRACTOR STATE, AND LOCAL LAWS AND ORDINANCES PERTAINING TO THE CONSTRUCTION OF THIS REFERS TO THE PERSON OR ENTITY RESPONSIBLE FOR PROVIDING ALL CONSTRUCTION DENTAL OFFICE. WORK. 3. MILLWORK SHALL BE DESIGNED BY THE MILLWORK SUPPLIER AND/OR DENTAL CABINETRY CONSTRUCTION DRAWINGS: SUPPLIER EXCEPT AS NOTED. * CONSTRUCTION DRAWINGS SHALL NOT BE SCALED IN ORDER TO DETERMINE LOCATIONS 4. BENCO SUGGESTS COMPLIANCE WITH CDC/OSHA RECOMMENDATIONS AGAINST INSTALLING OF ITEMS OF CONSTRUCTION. LARGER SCALE DETAILS TAKE PRECEDENCE OVER CARPETING IN TREATMENT ROOMS. SMALLER SCALE DETAILS. DIMENSIONED DETAILS TAKE PRECEDENCE OVER NON —DIMENSIONED DETAILS. 5. ALL HAZARDS, TEMPORARY OR OTHERWISE SHALL BE PROTECTED TO PRESERVE PUBLIC SAFETY. - THE WORD "FURNISH" IS USED TO MEAN "SUPPLY" COMPLETE WITH ALL ESSENTIAL ACCESSORIES SO THAT THE WORK WHEN INSTALLED FUNCTIONS FOR ITS INTENDED 6. BENCO WILL SUPPLY ALL DETAILED TEMPLATES AND/OR DETAIL MANUFACTURER'S USE, AND DELIVERY TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, INSTRUCTIONS. SUCH TEMPLATES AND INSTRUCTIONS WILL DEFINE THE LOCATIONS, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS. CONNECTIONS, AND SERVICES REQUIRED BY THE DENTAL EQUIPMENT. ERRORS RESULTING FROM THE FAILURE OF THE GENERAL CONTRACTOR TO FOLLOW THE INSTRUCTIONS o THE WORD "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE AND/OR TEMPLATES WILL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. INCLUDING THE UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, CONNECTING, PROTECTING, 7. DIMENSIONS FOR ALL DENTAL EQUIPMENT ARE CRITICAL AND MUST COMPLY WITH THE CLEANING, AND SIMILAR OPERATIONS NECESSARY FOR THE WORK TO FUNCTION FOR MANUFACTURER'S SPECIFICATIONS, AS SUPPLIED BY BENCO. BENCO WILL NOT ASSUME ITS INTENDED USE. RESPONSIBILITY FOR UNAUTHORIZED VARIATIONS TO THE PLANS AND/OR THE MANUFACTURER'S SPECIFICATIONS. Premier Communi ty o THE WORD "PROVIDE" MEANS "FURNISH AND INSTALL", AS DEFINED ABOVE, COMPLETE IN —PLACE AND READY FOR INTENDED USE. THE WORD "PROVIDE" THUS REQUIRES 8. WHERE NEW MATERIALS ARE TO BE APPLIED IN EXISTING AREAS, THE GENERAL INCLUSION OF ALL ACCESSORIES, ATTACHMENTS, SUPPORTS AND SERVICES NECESSARY CONTRACTOR WILL REMOVE EXISTING MATERIALS, AS REQUIRED, AND PROPERLY PREPARE TO COMPLY WITH THIS DEFINITION, WHETHER OR NOT SPECIFICALLY IDENTIFIED OR AREA TO RECEIVE THE NEW WORK. DESCRIBED IN THE CONSTRUCTION DOCUMENTS. 9. THE GENERAL CONTRACTOR WILL INSPECT ALL AREAS OF CONSTRUCTION AFTER ENVIRONMENTAL ASSESSMENT: COMPLETION OF THE WORK AND PROVIDE "REPAIR" AND "TOUCH—UP" PAINTING, IN ORDER H a the re e Z p hyrh e I lis * REMOVAL OF HAZARDOUS MATERIALS, IF IDENTIFIED BY ANY ENVIRONMENTAL TO RETURN AREA TO ORIGINAL CONDITION. ASSESSMENT PERFORMED BY AN ENVIRONMENTAL ENGINEER CONTRACTED BY THE 10. ALL WORK FOR ALL TRADES WILL BE GUARANTEED FOR A PERIOD OF ONE YEAR MINIMUM OWNER, SHALL BE COMPLETED BY WAY OF A HAZARDOUS MATERIALS REMOVAL FROM THE DATE OF ITS ACCEPTANCE. CONTRACT EXECUTED BY THE OWNER INDEPENDENT FROM AND PRIOR TO THE DATE OF COMMENCEMENT. 11. ALL MATERIALS INCORPORATED INTO THE WORK WILL BE NEW, UNLESS OTHERWISE NOTED. DADE CITY, FL 2. PERMIT SUBMISSION, REVIEWS, APPROVALS & FEES INSPECTIONS BY A BENCO REPRESENTATIVE ARE AN INTEGRAL PART OF OFFICE CONSTRUCTION. PERMIT SUBMISSION BY CONTRACTOR: 12. IT IS RESPONSIBILITY OF THE CUSTOMER OR HIS GENERAL CONTRACTOR TO ARRANGE FOR * THE CONTRACTOR SHALL SUBMIT THE APPLICATION FOR THE BUILDING PERMIT ALL MEETINGS, INCLUDING THE INITIAL REVIEW OF THE PLANS, SPECIFICATIONS, AND SUBMISSION, AND SHALL INCLUDE ALL REQUIRED DESIGN AND ENGINEERING DRAWINGS TEMPLATES AND ALL SUBSEQUENT INSPECTIONS. AND OTHER REQUIRED DOCUMENTS. BENCO DENTAL INSPECTIONS * THE CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT TO PROVIDE FOLLOW—UP COORDINATION WITH THE LOCAL JURISDICTION, AS REQUIRED, WITH RESPECT TO • INITIAL REVIEW OF THE PLANS, SPECIFICATIONS, AND FIELD CONDITIONS WITH THE BU ILDI NG— RELATED ISSUES THAT IMPACT THE APPROVAL AND RELEASE OF THE GENERAL CONTRACTOR, CARPENTER, PLUMBER, AND ELECTRICIAN BEFORE BUILDING PERMIT. RENOVATIONS BEGIN. o THE COST OF ARCHITECT/ENGINEER SIGNED/SEALED CONSTRUCTION DRAWINGS AND • INSPECTION AFTER FRAMING AND BLOCKING ARE COMPLETE, PLUMBING AND OTHER REQUIRED DOCUMENTS, AND TRANSMITTAL TO THE CONTRACTOR WILL BE THE ELECTRICAL LINES ARE INSTALLED, AND BEFORE WALLS AND/OR FLOORS ARE OWNER'S RESPONSIBILITY. CLOSED. a TIME AND MATERIAL COSTS FOR THE CONTRACTOR'S DELIVERY TO AND PICKUP FROM • FINAL INSPECTION AFTER FINISH WORK IS COMPLETE, TWO (2) DAYS PRIOR TO THE THE LOCAL JURISDICTION, AS APPLICABLE, WILL BE THE CONTRACTOR'S INSTALLATION OF DENTAL EQUIPMENT. RESPONSIBILITY. 13. BENCO WILL BE PROVIDED FIVE (5) DAYS ADVANCE NOTICE OF ALL MEETINGS. BUILDING PERMIT FEES: TO ARRANGE THE ABOVE, PLEASE CALL THE EQUIPMENT SPECIALIST LISTED UNDER THE PROJECT TEAM SECTION OF THE COVER SHEET. ALL BUILDING PERMIT FEES SHALL BE THE —CONTRACTOR'S RESPONSIBILITY, SHALL BE DUE AND PAYABLE TO THE LOCAL JURISDICTION ACCORDING TO THE LOCAL 14. CONTRACTOR SHALL CONSULT DOCTOR AND/OR BUILDING OWNER AND, WHERE APPLICABLE, JURISDICTION'S REQUIREMENTS, AND SHALL BE INCLUDED BY THE CONTRACTOR IN THE BE RESPONSIBLE FOR THE SUPPLY AND INSTALLATION OF THE FOLLOWING: BASE BID. PR03ECT TEAM a. UPGRADING AND INSTALLATION OF ELECTRICAL SERVICE TO DENTAL OFFICE CONTRACTOR LICENSE OR LOCAL SUBCONTRACTOR PERMITS: b. COMPLETE HVAC SYSTEM c. HOT WATER SYSTEM IF THE CONTRACTOR OR ANY SUBCONTRACTOR IS REQUIRED BY THE STATE OR LOCAL d. FIRE SAFETY DEVICES INCLUDING: ALARMS, DETECTORS, EXTINGUISHERS, ETC. JURISDICTION TO OBTAIN AN APPLICABLE CONTRACTOR LICENSE, OR ANY OTHER LOCAL e. ILLUMINATED EXIT SIGNS SUBCONTRACTOR PERMITS, SO AS TO PERMIT LEGAL WORK TO BE PROVIDED FOR THIS f. GENERAL AND EMERGENCY LIGHTING PROJECT, THEN THE CONTRACTOR IS RESPONSIBLE FOR ALL COSTS INCURRED TO g. TELEPHONE SYSTEM AND WIRING SATISFY THESE JURISDICTIONAL REQUIREMENTS. h. SOUND SYSTEM MATT LEA i. COMPUTER SYSTEM WIRING EQUIPMENT SPECIALIST ML8117@BENCO.COM o THE COST OF ANY AND ALL CONTRACTOR LICENSE(S), SUBCONTRACTOR TRADE (407) 488-2159 PERMITS, SERVICES AND INSPECTIONS SHALL BE THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE INCLUDED IN THE BASE BID. a THE PRINTING COST FOR DRAWINGS AND OTHER CONSTRUCTION DOCUMENTS REQUIRED PROJECT DESIGNER RONNIE LALUNIO FOR ANY CONTRACTOR LICENSE(S) OR SUBCONTRACTOR TRADE PERMITS SHALL BE THE CONTRACTOR'S RESPONSIBILITY, AND SHALL BE INCLUDED IN THE BASE BID. RMICTICE FINAL CERTIFICATE OF OCCUPANCY: ISOLUTIONS1 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE LOCAL JURISDICTION FINAL CERTIFICATE OF OCCUPANCY, OR ITS EQUIVALENT PERMIT, SO TO ALLOW THE OWNER TO COMMENCE FULL OPERATIONS, ON OR BEFORE THE DATE OF FINAL COMPLETION. 3. SITE UTILITIES 295 Centerpoint Blvd. 1-800-go-benco * APPLICATIONS FOR SITE UTILITY SERVICE TO THE TENANT SPACE SHALL BE Piffston, PA 18640 www.benco.com COORDINATED BY THE CONTRACTOR WITH THE OWNER. LOCAL SITE UTILITY PROVIDERS' POINTS OF CONTACT MAY BE INCLUDED IN THE DRAWINGS FOR REFERENCE PURPOSES. • THE CONTRACTOR SHALL COORDINATE THE ISSUANCE OF ALL LETTERS OF REQUEST FOR SITE UTILITY SERVICES WITH THE OWNER WITHOUT DELAY FOLLOWING THE AWARD OF THE CONTRACT FOR GENERAL CONSTRUCTION, SO AS TO CONFIRM SITE UTILITY SERVICES AND SCHEDULE CONNECTIONS AT THE EARLIEST POSSIBLE CALENDAR DATE. • ALL COORDINATION OF PROVISIONS FOR THE SITE UTILITY SERVICES BY THE CONTRACTOR SHALL BE INCLUDED IN THE BASE BID. FEES DUE AND PAYABLE TO THE LOCAL UTILITY SO AS TO FACILITATE PROVISIONS FOR SITE UTILITY SERVICES WILL BE DRAWING LIST EITHER THE OWNERS RESPONSIBILITY, OR THE OWNER MAY COORDINATE WITH THE CONTRACTOR FOR PAYMENT BY THE CONTRACTOR, WITH REIMBURSEMENT BY THE OWNER TO THE CONTRACTOR AT DIRECT COST. SHEET DRAWING TITLE ISSUED DATE QO. 1 COVER SHEET DENTAL CONST. DOCUMENTS 07/23/21 Q1.1 DENTAL EQUIPMENT PLAN DENTAL CONST. DOCUMENTS 07/23/21 Q2.1 DENTAL CARPENTRY PLAN DENTAL CONST. DOCUMENTS 07/23/21 Q2.2 DENTAL CARPENTRY DETAILS DENTAL CONST. DOCUMENTS 07/23/21 Q3.1 DENTAL ELECTRICAL PLAN DENTAL CONST. DOCUMENTS 07/23/21 Q3.2 DENTAL ELECTRICAL DETAILS DENTAL CONST. DOCUMENTS 07/23/21 SYMBOLS LEGEN D Q4.1 DENTAL PLUMBING PLAN DENTAL CONST. DOCUMENTS 07/23/21 WALL LEGEND Q4.2 DENTAL PLUMBING DETAILS DENTAL CONST. DOCUMENTS 07/23/21 DETAIL/SHEET TAG SINK TAG EXISTING WALL NEW WALL EQUIPMENT TAG NOTE TAG OAM a RACTICE �Auft I PSOLUTIONS PITTSTON, PA - DALLAS, TX - COSTA MESA, CA 11 . 8 0 0 . 4 6 2 . 3 6 2 6 / B E N 0 0 . C 0 M1 00 HermanMitter -6-1 IN E E 0 yj M N co co .j U. ISSUED: DATE: ZONE STUDY MM/DD/YY DESIGN SCHEMATIC 07/07121 DCD (FOR REVIEW) P7/23/21 DCD IMMIDD/YY C121070-RL DRAWN BY: I REVIEWED �CHECKED BY: OTHERS,RL I TH DRAWING TITLE COVER SHEET SHEET: Q0.1 I'_ " 1., - (5 z d rn Z z 50 _j E 8 5 z LI) T LJ M W D Z 0 z Z m Ld X En 0 0 ��, CL z x m CL In z 0 Lo =1 CL Lu C) La Z 00 N z 0 uj 0 2 U) z Z m 00 W :UDJ LJ w C) z 0 D III 00 09 w EL < w lir Lu Lu En Z 00 F- U.1 uj D _j _j < Ld In (n Ld z 0 w :3 x w 0 ci En Lu _j _j 0 68 w 3 m m cq 0 11.11 0 0 Z W C5 cj 0, z LLI m 0: 0 0 0 z z 0 LLI N a. 0 w Z a. U) Ld LLI 0 z W —0 . 0 w C-) w (f) w u- 0 LLI Z m w W M Lu Ld w LLI W C-) 0 0 z w Lu rh M z 0 Lj Ld 0 Q z CL Ld Z Z w cn LL. 00 0 z li m w m w tz mn 0 W (L tan p L3 In 0 U) (L w V; z 0 Li 0 LLJ1 a- (n v; z o < z z 0 D v; w t; z 0-0 0 1L_5p-6"p'1 5 p -8 PIP 12 -4 PIP p -9. _4 5 R CPI A 5n T Ct, EMOTE 04 3 STOR. 'u CONTROL I PANEL -u-) 2 1 10 MEC 4 STERILE/ LAB NEW BREAK CORR. C ROOM 1 (D--7 (0 i EXIST NEW STOR ELEC DE#4 2 -1 DENTAL EQUIPMENT LEGEND r7711%. PROVIDERS DESCRIPTION STATUS LOCATION 0 NEW 0 ADA STAF 1 MIDMARK P22 OIL -LESS AIR COMPRESSOR NEW MECH. ROOM 0 2 MIDMARK POWERVAC P3 VACUUM PUMP NEW MECH. ROOM CORR. D 3 SOLMETEX HG5 AMALGAM SEPARATOR NEW MECH. ROOM r7 4 MIDMARK REMOTE WATER CONTROL VALVE NEW MECH. ROOM -0) C-L4d CORR. B FEA N 5 MIDMARK 3-BUTTON REMOTE CONTROL PANEL (A/W/V) NEW NEW BREAK ROOM 1 6 MIADMARK ULTRATRIM LR CHAIR, ASEPSIS 21 UNIT, ASSISrS INSTR. NEW ALL O.P.s UNIT REAR HUB MOUNT, & LED LR OPERATING LIGHT PROCENTER STOR ?1 10 3 COMMUNITY 7 MIDMARK REAR CABINET w/ PIVOTING WORK SURFACE ONLY NEW ALL O.P.s SERVICE 8 MIDMARK SIDE CABINET NEW ALL O.P.s 6#-7" 9 MIDMARK SIDE CABINET w/ SINK AND UPPER NEW O.P.#1 NEW 10 INSTRUMENTARIUM OP 2D PAN X-RAY NEW PAN DF C2 11 MIDMARK STERI AND LAB CENTER NEW STERILi MISCELLANEOUS SMIRILIZATION EQUIPMENT ADMIN. 12 QUICK CLEAN ULTRASONIC, NEW STERILE (VERIFY LOCATIONS) -- :CH if rL STATIM 5000 AUTOCLAVE, & M1 1 AUTOCLAVE 13 MISCELLANEOUS LAB EQUIPMEN NEW LAB (VERIFY LOCATIONS) DISPOSABLE PLASTER TRAP, MODEL TRIMMER, & LATHE NOMAD X-RAY NEW REMAINING MISCELLANEOUS CA13INETRY & MILLWORK BY OTHERS NEW AS SHOWN ON EQUIPMENT PLAN CORR. A PRIVATE DENTAL DEC WAITIN L1 .1 (0 0 ------- ENTRY 19 L AD 6\aATIE i III 71111\ 1 ADA LOBB PATIENTS 1 0 Fo� S?DENTAL EQUIPMENT PLAN CALE: 1/4" = 1'-0" PRACTICE SOLUTIONS PITTST DA LAS,TX - C S A 1 .8 0 0 . 4 6 2 .3 6 2 6 1 B E N 0 0 . C 0 M (9 HermanMitter cn cu cu .j U. ISSUED: DATE: ZONE STUDY MM/DD/YY DESIGN SCHEMATIC 07/07/21 DCD (FOR REVIEW) 07123/21 DCD IMM/DD/YY PROJECT #: C121070-RL DRAWN BY: I REVIEWED BY: HECKED BY: OTHERS,RL I TH DRAWING TITLE: DENTAL EQUIPMENT PLAN SHEET: Q1.1 I 'Jill 1 ­1 �,E 'I'I'lk __F_ , ill , di ! 111h I ill I I 1 .8 0 0 . 4 6 2 .3 6 2 6 1 B E N 0 0 . C 0 M (9 HermanMitter cn cu cu .j U. ISSUED: DATE: ZONE STUDY MM/DD/YY DESIGN SCHEMATIC 07/07/21 DCD (FOR REVIEW) 07123/21 DCD IMM/DD/YY PROJECT #: C121070-RL DRAWN BY: I REVIEWED BY: HECKED BY: OTHERS,RL I TH DRAWING TITLE: DENTAL EQUIPMENT PLAN SHEET: Q1.1 I 'Jill 1 ­1 �,E 'I'I'lk __F_ , ill , di ! 111h I ill I I C121070-RL DRAWN BY: I REVIEWED BY: HECKED BY: OTHERS,RL I TH DRAWING TITLE: DENTAL EQUIPMENT PLAN SHEET: Q1.1 I 'Jill 1 ­1 �,E 'I'I'lk __F_ , ill , di ! 111h I ill I I (5 Z Z z w :g 0 _j 13 8 5 z U) V) :D LU m V) Z z Z m Ld cn 0 (L z X D z 0 Lo La 0 Z Ld (n od a 0 LLJ 0 2 Z 's D L&j m 00 W LU z 00 z 0 D Li 00 09 cr- (L < Ld X Ix 0 LL Li La M (n V) L� Z 00 n V) �uj X tn- z Li LLI m: LLI -j Ld V) V) LLI z 0 Ld x Lu >1 �E 0 EL 0 V) Lu V) _j 00 o z Lu Ld m u) LLI i'! o Lu L) �3 (3 W Z on o Z LLJ m z LLJ m 0 00 z z 0 Ld N a- 0 W Z (L 0 U) W Lu L) z < 0 L) L) X 0 9 cr Li Z m Lu :D LLI w M t� La Z Lu 3: LJ C.) uj (n 2-1 F- ILL C-) 0 LLI :� fn 0 z 4D Li LU M z C-) Ld 2 F 0 z (L L) Ld Z of L; L) Z E/) Li cn 0 0 u- 08 z w m Ld 0 m z m: 0 X It LLI (L m Of rn o p Lj tzi U) �d 0 U) (L X V; =) z (L 0 M 3: UJI (L V) vi z 0 < z z 0 Ir tT) z 0 (L .DENTAL CARPENTRY PLAN & DETAILS SCALE: 1/4" = 1p—Opp [01LIV ;I:% z I 1. THE DRAWING IS DIMENSIONED FROM THE FACE OF A FINISH WALL TO THE FACE OF A FINISH WALL, UNLESS OTHERWISE NOTED. THE DENTAL EQUIPMENT WILL BE DIMENSIONED FROM THE FACE OF A FINISH WALL TO THE CENTERLINE OF THE EQUIPMENT, UNLESS OTHERWISE NOTED. 2. PARTITIONS SHOWN ARE 5" NOMINAL. 3. ALL BLOCKING WILL BE INSTALLED FLUSH WITH THE FACE OF THE STUDS. 4. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE TO BRACE AND PROTECT ALL WORK DURING CONSTRUC11ON AGAINST DAMAGE, BREAKAGES, COLLAPSE, DISTORTIONS, AND OFF —ALIGNMENT ACCORDING TO APPLICABLE CODES, STANDARDS, AND GOOD PRACTICE. 5. THE CARPENTER WILL BE RESPONSIBLE FOR BOTH THE STRUCTURAL INTEGRITY AND THE STABILITY OF ALL BLOCKING AND WALL SUPPORT. 6. THE CARPENTER WILI COMPLY WITH ALL BENCO INSPECTIONS, AS NOTED IN THE GENERAL NOTES IN THE FIRST SECTION OF THESE DOCUMENTS. 7. VERIFY LOCAL & STATE X—RAY SHIELDING REQUIREMENTS WITH ARCHITECT, CONTRACTOR OR CLIENT. SECURE TOP PLATE TO STRUCTURE ABOVE TWO (2) 2x12 WOOD BACKING TYPICAL 2x4 STIFFENING STUD CENTERLINE INDICATED BY DIMENSION ON PLAN DETAIL - TYPICAL PAN X-RAY BACKING 01 REF.: SOURCE: N.T.S. 2x10 WOOD BLOCK[NG OR KITCHEN STEEL FOR THE LENGTH OF THE CASEWORK. CASEWORK SUPPLIED AND INSTALLED BY BENCO. CD 00 — 2x10 WOOD BLOCKING OR KITCHEN STEEL FOR THE LENGTH OF THE CASEWORK. 1, J, DETAIL- TYPICAL CASEWORK BLOCKING IN TRIS 02 REF.: SOURCE: N.T.S. 2x10 WOOD BLOCKING OR KITCHEN STEEL FOR THE LENGTH OF THE CASEWORK. CASEWORK SUPPLIED AND INSTALLED BY BENCO. 00 2x10 WOOD BLOCKING OR KITCHEN STEEL FOR THE LENGTH OF THE co CASEWORK. p DETAIL - TYPICAL CASEWORK BLOCKING 03 REF.: SOURCE: N.T.S. 0,mmmAptifte I PiTTSTON, PA - DALLAS,TX 1 . 0 0 0 . 4 6 2 . 3 6 2 6 PRACTICE SOLUTIONS COSTA MESA , CA D E N C 0 .0 0 M IV HermanMitter NE E E 0 0 E CL cn Jc ro a) N cu 0 Jc 6--j -i U. 4-4 ISSUED: DATE: ZONE STUDY MM/DDIYY DESIGN SCHEMATIC 07107/21 DCD (FOR REVIEW) 07/23/21 DCD IMM/DD[YY PROJECT #: C121070-RL DRAWN BY: I RENAEWED BY: CHECKED BY: OTHERS,RL TH DRAWING TITLE: DENTAL CARPENTRY PLAN & DETAILS SHEET: Q2.1 --------------------- T I— -- � I 1 11 - I I — — — - — — I I I Ili l''I I v - , I ill"ll 11111h; I . � '1 1 1 1 (5 Z ci Z 50 two z tn En W m 0 Z Fn Z 0 cn 0 11 0 IL a z 0- V) z 0 Lo 2 CL CL uj Z Lu Z V) 0 L� N odV) 8 o Li L) 0 z 's ui m F- 'o 00. LLJ V) ui z 00 z 0 w m w 0 09 (X CL < LLJ (y 0 >_ i 0 LU uj In in v) Ll Z 00 IL 112 'w Ir 2F Ir LLI _j -i Fo- < Lu U) V) uj z 0 LU D C) I m 0 0 0 (L (n (n 0 z LLJ Li cn LLI R': 8 LLI 12 1 w Z On 0 _j Z LLJ 66 o 0, z LU m m 0 00 Z z a. Z < Lq 0 (1) Li Li 0 z w Lu v) 0 uJ LLJ Z m ui :D LAJ M z r- LLJ = LJ F- 0 �i c� Li LLJ U) LL 0 0 z C-) w w W M z 0 Li z Ll 513 5 = _j a. 0 LJ Z Ld Z V) LLI Li 0 U- 08 z LLJ m C; z 0 M = LLI (L u) Li Ln 0 EL V; z IL 0 M cn (15 0 C.3 � z z 0 :D m 1:5 z 0 (L �E N A I L� �Rl C �AL �IL A �N L 1 ?A E�X 4� ELECTRICAL NOTES 1. ALL EQUIPMENT WILL BE SINGLE PHASE, UNLESS OTHERWISE NOTED. 2. ALL WIRING WILL BE CONCEALED WITHIN THE WALLS AND/OR FLOOR, UNLESS OTHERWISE NOTED. 3. THE ELECTRICIAN WILL TAG ALL WIRES AT TERMINATION POINTS, 4. THE ELECTRICIAN WILL REMOVE ALL EXISTING RECEPTACLES AND SWITCHES IN THE AREA OF WORK. THE ELECTRICIAN WILL EITHER INSTALL A BLANK PLATE OVER RECEPTACLE OR SWITCH BOX OR REMOVE BOX ENTIRELY. THE ELECTRICIAN WILL TERMINATE WIRING AND CONDUIT IN A MANNER IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE. 5. THE ELECTRICIAN WILL INSTALL COMPLETE AND MAKE FINAL HOOK-UP TO THE FOLLOWING DENTAL EQUIPMENT, SUPPLIED BY EITHER THE DOCTOR OR BENCO DENTAL, INCLUDING, BUT NOT LIMITED TO: - AIR COMPRESSOR - VACUUM PUMP - WATER CONTROL VALVE - CONTROL PANEL 6. THE ELECTRICIAN WILL BE ONSITE ON THE DAY(S) OF INSTALLATION TO WORK WITH THE BENCO REPRESENTATIVE ON FINAL HOOK-UP. THE ELECTRICIAN WILL SUPPLY AND INSTALL ANY AND ALL MATERIALS INDICATED IN THE ELECTRICAL DETAILS SHOWN AND MANUFACTURER'S INSTALLATION INSTRUCTION SHEETS. 7. IN THE EVENT OF ANY EQUIPMENT BEING RELOCATED TO ANOTHER LOCATION, ANY AND ALL CIRCUITS MUST BE TERMINATED BY THE ELECTRICIAN IN ACCORDANCE WITH LOCAL CODE. VERIFY RESPONSIBILITY WITH THE OWNER. 8. THE ELECTRICIAN WILL SEAL ALL PENETRATIONS THROUGH THE FLOOR WITH A FIRESTOP OR EQUIVALENT WATERPROOFING. 9. THE ELECTRICIAN WILL COMPLY WITH ALL BENCO INSPECTIONS, AS NOTED IN THE GENERAL NOTES ON THE FIRST PAGE OF THESE DOCUMENTS. 10. ALL 120 VOLT, 20 AMP OUTLETS INSTALLED WITHIN 6 FEET OF A SINK AND THOSE LOCATED OUTDOORS SHALL HAVE GFCI PROTECTION. 11. ALL 120 VOLT, 20 AMP DENTAL EQUIPMENT OUTLETS INSTALLED WITHIN 6 FEET OF A WATER SOURCE SHALL HAVE GFCI PROTECTION. NOTES LEGEND RECEPTACLES ABOVE &/OR BELOW COUNTERTOPS (VERIFY QUANTITY & LOCATION WITH BENCO REP AT TIME OF LAYOUT) ULTRASONIC CLEANER RECEPTACLE - 11OV, 20 AMP CIRCUIT (VERIFY LOCATION W/BENCO REP AT TIME OF LAYOUT) AUTOCLAVE RECEPTACLE - 11OV, 20 AMP SEPARATE CIRCUIT (VERIFY LOCATION & QUANTITY W/BENCO REP AT TIME OF LAYOUT) q) 2" CONDUIT (SEE DETAIL 08 ON SHEET Q3.2) ELEMICAL LEGEND SYMBOL DESCRIPTION THERMOSTATIC ON/OFF SWITCH WIRING, CONCEALED IN WALL OR CEILING EXHAUST FAN MOUNTED IN CEILING (VERIFY CFM REQUIREMENTS WITH ARCHITECT) EXPOSURE BUTTON CONDUIT, CONCEALED IN FLOOR AmAiaIiiini'lowifte I P�TTSTON, PA - DALLAS,TX I . 8 0 0 . 4 6 2 , 3 6 2 6 / PRACTICE SOLUTIONS COSTA MESA, CA B E N C 0 . C 0 M qp HermanMitter C E E 0 0 E cn Jc N I m 4-a ;I 4-1 cu 0 ISSUED � DATE: ZONE STUDY MM/DD/YY DESIGN SCHEMATIC 07/07/21 DCD (FOR REVIEW) 07123/21 DCD MM/DDNY C121070-RL DRAWN BY: I REVIEWED �.CHECKEDBY: OTHERS,RL I TH DRAWING TITLE: SHEET: DENTAL ELECTRICAL PLAN Q3.1 � � I.. I'll ­1 1 (5 Z Z L&J �_ L� 1F 0 _j z W EQ Z i5 Z 35 0 => z m Lj 0: U) 0 0 (L V) 0 Q 0 -1 LL a- I�L LLI < Z ui Z (f) 0 L_ N od a 0 Lj V 2 Z zs LLJ m 00 LLJ V) Uj z 00 z 0 LLJ 00 09 m CL < W x 0 uj Q W M U) F) L_ Z 00 EL U) p Ld z LLJ 2 5 LLJ Ld _j _j < LJ V) V) LLJ z 0 Ld x LJ �E 0 0 V) _j :j Q 0 60 LLJ 6 m Ld & 00 Ld 0 �3 0 O� Z 0 Z LLJ M m _j C5 < 08 z _j LAJ m 0 t� 0 CD z z CL 0 Z Ld L11 0 F_ z uJ _J 0 0 Ir uj Ld Ld LJ 0 Lj U) > LA_ 0 z C) W 0 LLJ � z 0 Lj LLJ 0 LJ z :n IL 0 Ll z of LLI 6 Z Lo 0 LL 00 0 f2 z 1.1 z Ill Lu 0 W CL on U) z Ld uj 0- < U) cf; z 0 < z z 1 0 a z a- 0 220V, DEDICATED 20A POWER SUPPLY NOTE: PROVIDE BUCK/BOOST TRANSFORMER AS NEEDED TO MAINTAIN A MINIMUM OF 208V TO UNIT. NOMINAL 2"x,3" ELECTRICAL BOX WITH 0 B D F OsT D To AIR COMPRESSOR: MIDMARK P22 04 E DISCONNECT SWITCH COVER PLATE WITH HOLE. 4—#18'S SUPPLIED BY CONTRACTOR. (STRAND WIRE) TO CONTROL PANEL, LEAVE 4' TAIL OF WIRES OUT FROM POWER CORD (SUPPLIED BOX. SUPPLIED BY CONTRACTOR W/UNIT) HARD WIRED TO DISCONNECT SWITCH FULL LOAD AMPS: 7A 11E (0 n 27"Hx26"Wx24"D w/o SOUND COVER 32"Hx26"Wx25"D with SOUND COVER SHIP WEIGHT: 285 LBS. SUPPLIED BY BENCO DENTAL. INSTALLED BY CONTRACTOR. VACUUM UNIT: MIDMARK P3 FULL LOAD AMPS; 11.4 58"Hx 1 9.5"Wx 1 8.5"D SHIP WEIGHT: BASE = 402 LBS. TANK = 68 LBS. SUPPLIED BY BENCO I INSTALLED BY CONTRAC 220V, DEDICATED 30A POWER SUPPLY NOTE: PROVIDE BUCK/BOOST TRANSFORMER AS NEEDED TO MAINTAIN A MINIMUM OF 208V TO UNIT. NOMINAL 2"x3" ELECTRICAL BOX WITH COVER PLATE WITH Y2" HOLE. 4—#18' (STRAND WIRE) TO CONTROL PANEL, LEAVE 4' TAIL OF WIRES OUT FROM BOX. SUPPLIED BY CONTRACTOR DISCONNECT SWITCH SUPPLIED BY CONTRACTOR. POWER CORD (SUPPLIED W/UNIT) HARD WIRED TO DISCONNECT SWITCH INSTALL 4—#18 WIRES FROM CONTROL VALVE TRANSFORMER TO CONTROL PANEL. NOTE: IF DISTANCE EXCEEDS 100' USE 16 GA WIRE INSTALL TWO #18 WIRES FROM CONTROL VALVE TRANSFORMER TO WATER CONTROL VALVE. WATER CONTROL VALVE TRANSFORMER SUPPLIED BY BENCO DENTAL. MOUNT WITHIN 18" OF WATER CONTROL VALVE MOUNTED BY PLUMBER. 115v 20a GFCI OUTLET NOTE: UNIT MAY VARY FROM DESIGN SHOWN, SEE MANUFACTURER'S INSTALLATION GUIDE. u 06 UU0 fo .' 600SPOL AN 4—#18 LOW VOLTAGE WIRES (TO EAC H U N IT) CONTROL PANEL MIDMARK SUPPLIED BY BENCO DENTAL CONTRACTOR TO SUPPLY APPROPRIATELY SIZED ROUGH —IN BOX FOR CONTROL PANEL. SEE BENCO REPRESENTATIVE FOR EXACT ROUGH —IN BOX SIZING. DETAIL - AIR COMPRESSOR 01 DETAIL -VACUUM PUMP 02 DETAIL- WATER CONTROL VALVE 03 DETAIL - CONTROL PANEL 04 REF.: SOURCE: N.T.S. RER: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. MOUNT EXPOSURE — SWITCH TO 2x4 BOX (SUPPLIED BY CONTRACTOR) OR DIRECTLY TO WALL INSTALL 1"0 CONDUIT — THROUGH CEILING WITH MANUFACTURER'S CABLE SUPPLIED BY BENCO. INSTALL 220V, 20A SEPARATE CIRCUIT UNIT TO BE HARD WIRED INSTALL 4x4 ROUGH —IN - BOX WITH SINGLE MUD RING, BLANK FACE PLATE WITH 3/4" GROMMET NOMINAL 2"x3" ELEC. BOX WITH COVER PLATE FOR DATA CABLES. SUPPLIED BY CONTRACTC SUPPLY CONDUIT AS RE( PANORAMIC X—RAY: INSTRUMENTARIUM OP-2D 88.15"Hx37.8"Wx48.8"D FULL LOAD AMPS: 10A INE 115v 20a FLEX WIRE WITH 6" PIGTAIL AND QUAD RECEPTACLE. (GFCl RECEPTACLES REQUIRED WITHIN 6' OF A WATER SOURCE) NOTE: SEE MANUFACTURER'S TEMPLATE FOR EXACT ROUGH —IN LOCATION. TREATMENT ROOM 1� CONSOLE 11 5v 20a FLEX WIRE WITH 6" PIGTAIL AND QUAD RECEPTACLE. (GFCI RECEPTACLES REQUIRED NOTE: SEE MANUFAC WITHIN 6' OF A WATER SOURCE) TEMPLATE FOR EXAC LOCATIONS, NOTE: 2" CONDUIT FOR CC SEE MANUFACTURER'S TEMPLATE DATA CABLES. FOR EXACT ROUGH —IN LOCATION. UTILITY CENTER BEL( \CHAIR f � FLOOR QC'Al r)0C'KIIKIf'Q A _.� 1 11 L-W L.� DETAIL - PANORAMIC X-RAY WIRING 05 DETAIL - DENTAL CHAIR RECEPTACLE 06 DETAIL - REAR CABINET RECEPTACLE 07 DETAIL - TYP. TREATMENT ROOM CONDUITS 08 REF.: SOURCE: N.T.S. RER: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. DETAIL 09 DETAIL 10 DETAIL 11 DETAIL 12 REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. DETAIL 13 DETAIL 14 DETAIL 15 DETAIL 16 REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. IMMASAWAfte PRACTICE U I SOLUTIONS PITTSTON, PA - DALLAS, TX - COSTA MESA, CA 1 . 8 0 0 . 4 6 2 . 3 6 2 6 / B E N C 0 . C 0 M 0 HermanMiller 4-1 C =3 E E 7j� N m 0 Jc I j m .j U. 4_0 cu 0 ISSUED: DATE: ZONESTUDY MM/DD/YY DESIGN SCHEMATIC 07/07/21 DCD (FOR REVIEW) 07/23/21 DCD !MM/DDNY C121070-RL DRAWN BY 71 REVI�BY.- CHECKED BY: OTHERS,RL I TH DRAWING TITLE: DENTAL ELECTRICAL DETAILS SHEET: Q3.2 111 7-1 IF Z ci Z z Ld _j z LJ m in :3 Z z 0 m ct cn 0 0 "� (L z m CL z 0 < '6 to _j , CL w 0 Z Ld Z (f) 0 Ll N off !W i a 0 LLJ L) 2 =) 0 f5 z V)!3 z , LU M 00. LLJ w z 00 oz 9 Ir LU 0 0 R 9 (L < w M a W 2 �_ > Er w (n En Ll Z 00 CL tn w It tn- z ED w w _j z 0 L11 D 0 x Ld >1 0 (L Q U) V, D _j 0 0 o z LLI W m cq e'� 0 Uj L) Pu o 0� Z on 5 Z Lj m _j c; 0 0 0 z Ld m 0 OD Z z 0 LLJ N 0- 0 jr Z a. Lq 0 U) LLJ LLI L) z 0- I 0 L) LLJ 0 9 I= Lu Z m Lo Ld M w Ld LI is L) >: I Li U) Z-1 LL 0 0 z L) Lu ro M z 0 Lu W z W Z LLT L) Z 50_�' 12 LLI o W In LL 00 L) z w z M Lu z 0 X 0: LU (L m 8R o Li In 0 U) V; z 0 IR- LLJ (L < V) E6 z C.D < z z 1 0 0 � D V; " V) z 0 (L 0 (D�TE� PL��BING PLAN .�A Z 4� SINK LEGEND 1 THE PLUMBER WILL SUPPLY AND INSTALL A WATER PRESSURE REGULATOR ON INCOMING WATER SUPPLY. THE PLUMBER WILL SET THE REGULATOR NOT TO EXCEED 65 PSI. 2. THE PLUMBER WILL INSTALL THE WATER FILTER (AND THE WATER SOFTENER, AS NEEDED) ON THE COLD WATER MAIN ENTERING THE DENTAL SUITE. THE WATER FILTER WILL BE SUPPLIED BY EITHER BENCO DENTAL OR THE DOCTOR. 3. THE PLUMBER WILL SUPPLY AND INSTALL SEPARATE MANUAL SHUT—OFF VALVES ON ALL SINKS, DENTAL UNITS, AND OUTLETS REQUIRING WATER AND/OR AIR. 4. ALL SINKS AND FAUCETS WILL BE CONNECTED BY THE PLUMBER. 5. ALL PIPES WILL BE CONCEALED WITHIN THE WALLS AND/OR THE FLOOR, UNLESS OTHERWISE NOTED ON THE BENCO DRAWINGS. 6. THE PLUMBER WILL SEAL ALL PENETRATIONS THROUGH THE FLOOR WITH A FIRESTOP OR EQUIVALENT WATERPROOFING. 7. ALL PIPES WILL BE FLUSHED CLEAR OF ALL DEBRIS BY THE PLUMBER. 8. THE PLUMBER WILL BE ONSITE ON THE DAY(S) OF INSTALLAnON TO WORK WITH THE BENCO REPRESENTATIVE ON THE FINAL HOOK—UP. THE PLUMBER WILL SUPPLY AND INSTALL ANY AND ALL MATERIALS INDICATED IN THE PLUMBING DETAILS SHOWN AND THE MANUFACTURER'S INSTALLATION INSTRUC71ON SHEETS. 9. THE PLUMBER WILL PROVIDE AND INSTALL ALL WATER SAFETY DEVICES (i.e. CHECK VALVES, BACKFLOW PREVENTERS, ErC.) IN ACCORDANCE WITH LOCAL CODE. 10. THE PLUMBER WILL INSTALL COMPLETE AND MAKE FINAL HOOK—UP TO THE FOLLOWING DENTAL EQUIPMENT, SUPPLIED BY THE DOCTOR AND/OR BENCO DENTAL, INCLUDING, BUT NOT LIMITED TO: — AIR COMPRESSOR — VACUUM PUMP — AIR/WATER SEPARATORS — WATER CONTROL VALVE AND FILTER ASSEMBLY 11. AN ELECTRIC MASTER WATER CONTROL VALVE AND FILTER ASSEMBLY IS REQUIRED FOR ANY/ALL COLD WATER LINES FEEDING ALL DENTAL EQUIPMENT. THIS WATER CONTROL VALVE AND FILTER ASSEMBLY IS REQUIRED WHETHER SUPPLIED BY BENCO, THE DOCTOR, OR THE PLUMBER. THE PLUMBER IS TO VERIFY THE EXACT LOCATION OF THE WATER CONTROL VALVE AND FILTER ASSEMBLY WITH THE DOCTOR/OWNER, AND A BENCO REP AT THE TIME OF LAYOUT AND PRIOR TO EQUIPMENT SELECTION. 12. THE PLUMBER WILL COMPLY WITH ALL BENCO INSPECTIONS, AS NOTED IN THE GENERAL NOTES ON THE FIRST PAGE OF THESE DOCUMENTS. 13. GENERAL DENTAL PLUMBING LINES SHOWN ARE FOR GRAPHICALLY DISPLAYING ORIGINATION AND TERMINATION POINTS. FIELD CONDITIONS MAY ALTER PLUMBING LINE LAYOUT, PER PLUMBERS DISCRETION. THE FINAL LAYOUT OF THE PLUMBING LINES IS THE RESPONSIBILITY OF THE PLUMBER. 14. THE APPLICATION OF DRIVE GAS (NFPA, 2012, 99.5.3.7, AS THIS IS NOT CONSIDERED NFPA "AIR" ) AS NOTED ON THIS PLAN IS NOT USED FOR LIFE—SUPPORT PURPOSES SUCH AS RESPIRATORS, IPPS MACHINES, ANALGESIA, ANESTHESIA, AND SO FORTH. 15. NFPA, 2012, 99.5.3.8 VACUUM PIPING 16. NFPA, 2012, 99.5.3.8 SCAVENGING PIPING NFPA LEGEND SYMBOL NFPA 2012/2015 NFPA 2018 O=OXYGEN 99.5.3.6 99.15.4.4.2 N=NITROUS OXIDE 99.5.3.6 99.15.4.4.2 S=SCAVENGING 99.5.3.8 99.15.4.4.4 V=VACUUM 99.5.3.8 99.15.4.4.4 D=DRIVE GAS/ DENTAL AIR 99.5.3.6 99.15.4.3.3.2 99.15.4.4.3 W=W.A.G.D. 99.5.3.8 99.15.3.2.1.5 SINK — SINK, FAUCET AND STRAINER SUPPLIED BY OTHERS. PLUMBER SHALL INSTALL HOT AND COLD WATER LINES, WASTE AND TRAP ROUGH —IN PER LOCAL CODES. SJUK — SINK, FAUCET AND STRAINER PROVIDED WITH CABINETRY SUPPLIED BY BENCO. PLUMBER SHALL INSTALL HOT AND COLD WATER LINES, WASTE AND TRAP ROUGH —IN PER LOCAL CODES. PLUMBER SHALL BE RESPONSIBLE FOR FINAL HOOKUP. SEE MANUFACTURER'S SPECIFICATIONS FOR EXACT LOCATION AND REQUIREMENTS. NFPA REFERENCES FOR N20/02 (NON -ANESTHESIA) 2012 2015 2018 MED GAS PIPING, BRAZING, & TESTING 99.5.3.6 99.5.3.6 99.15.4 MED GAS STORAGE 99.11.3 99.11.3 99.11.3 MED GAS STORAGE VENTILATION NATURAL: MECHANICAL- 99.9.3.6.5.2 99.9.3.6.5.3 99.9.3.6.5.2 99.9.3.6.5.3 99.9.3.6.5.2 99.9.3.6.5.3 CATEGORY 3 DRIVE GAS 99.5.3.7 99.5.3.7 DENTAL AIR 99.15.4.3.3.2 CATEGORY 3 VACUUM 99.5.3.8 99.5.3.8 DENTAL VACUUM 99.15.4.3.3.3 CATEGORY 3 SCAVENGING 99.5.3.8 99.5.3.8 NITROUS OXIDE SCAVENGING 99.15.4.3.3.4 filAummatake mclotu PITTSTON, PA - DALLAS,TX I . 8 0 0 . 4 6 2 . 3 6 2 6 / PRACTICE SOLUTIONS COSTA MESA, CA B E N C 0 . C 0 M IV HermanMitter C E E 0 0 E n cn cu 0 Jc f j i4 mq .j LL ISSUED: DATE: ZONE STUDY MM/DD/YY DESIGN SCHEMATIC 07/07/21 DCD (FOR REVIEW) 07/23/21 DCD IMM/DDNY PROJECT #: C121070-RL DRAWN BY: t REVIEWED BY.TCHECKED BY: TH OTHERS,RL _T DRAWING TITLE: DENTAL PLUMBING PLAN SHEET: Q4.1 (6 Z ci Z z 0 _j E 8:5 z V) W Z a z K 03 LL; W U) 0 ol-, EL x M 0- En z 0 cr Lo :3 a. Lu 0 Z Lu Z V) 0 U- N off In 0 LU U Z Ld F- L3__ 1 5 0 _j LU LLI jr z 00 z 0 n LLI a L) 29 CL < Ld ir 0 LU M (n V) L� Z 00 CL (n W z m ui Lj _j Ld _j Ld V) 0 LU z 0 LJ =) 0 _j ,u x Ld 0 EL Q U) Lu _j >U) 30 Q 0 60 z LLJ Lj m U) 0 0 0 z 09 L) Z Q Lj M m _j 66 o 0 z W m 0 00 Z �z 0 LLJ N (L 0 �j Of 0 (n Lu L) z =1 IL M Ld C) M ;> 2 cn fr LU Z LLI LLJ uj z E_ uj W �s () ti � W L0 > LL 0 z L) W U9 ri) m z U La 2 F 0 p z Ld F, 3 a. 0- z LLS 0 Z � U) W LLj ,0 D 00 0 f2 Z hl z m Ld 0 Lj 0 U) CL z CL 0 (r IS W iz 0 W (L v> 0 ui z 0 < z z 0 z (L 0 0 2" PVC SCH#40 PIPE TO ABOVE CEILING OR TO NEAREST RETURN AIR DUCT FOR FRESH AIR MANIFOLD AND FLEX CONNECTING TUBING SUPPLIED BY BENCO DENTAL Y2-0 COPPER LINE TO ALL LOCATIONS/UNITS REQUIRING DRIVE GAS/DENTAL AIR AIR COMPRESSOR: MIDMARK P22 27"Hx26"Wx24"D w/o SOUND COVER 32"Hx26"Wx25"D with SOUND COVER SHIP WEIGHT: 285 LBS. SUPPLIED BY BENCO DENTAL. INSTALLED BY CONTRACTOR. INSTALL 2"0 GALVANIZED STEEL Y2" COLD WATER LINE PIPING OR COPPER PIPING TERMINATED WITH BALL (TYPE M) FOR FIRST 15' THEN VALVE AND GARDEN HOSE SWITCH TO 2"0 PVC SCH#40 CONNECTION PIPING "DRY" EXHAUST VENT TO OUTSIDE. INSTALL 1)/2"0 PVC SCH#40 /1101 VACUUM HEADER FROM VACUUM UNIT: TREATMENT ROOMS. MIDMARK P3 (SEE DETAILS 03 & 58"Hxl9.5"Wxl8.5"D 04 THIS SHEET) SHIP WEIGHT: BASE = 402 LBS. COLLECTION DRAIN OPTIONS TANK = 68 LBS. TANK CLOM om SUPPLIED BY BENCO DENTAL. yum MN um PIPE 011, INSTALLED BY CONTRACTOR. POWER UNIT 2" FLOOR DRAIN //—(OPTIONAL DRAIN CONNECTIONS SHOWN ABOVE) USE ONLY 45' OR LONG RADIUS, DWV FITTINGS WHEREVER POSSIBLE. NO 'HEAD—ON' INTERSECTIONS (TEES OR CROSSES) OR SAGS ANYWHERE. ALL LINES FALL WITH A DROP OF )14"' IN EVERY TEN FEET OF LENGTH TOWARDS THE CENTRAL VACUUM UNIT. USE ONLY D.W.V. FITTINGS ON THE MAIN TO ACCEPT SMALLER PIPE SIZES. INSTALL X" STRAIGHT COPPER STUB 2" ABOVE FINISHED FLOOR OR MANUFACTURES SUPPLIED VACUUM TERMINATION CONNECTOR. TOP OF DECK lY2" PVC RISER %" PVC SCH #40 HEADER WITH A Y4" PER 10ft SLOPE DOWN AND BACK TO THE VACUUM PRODUCER NOTE: USE LONG SWEEP FITTINGS AND WYES DETAIL - AIR COMPRESSOR 01 DETAIL -VACUUM PUMP 02 1 DETAIL- VACUUM PIPING 03 1 DETAIL- VACUUM PIPING 04. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. I REF.: SOURCE: N.T.S. I REF.: SOURCE: N.T.S $I ­ ­ __ I A2 .)Irl?T'+U VACUUM UNI- SEE VACUUM PUMP DETAIL VACUUM HEADER FROM TREATMENT ROOMS. SOLMETEX hg5 AMALGAM SEPARATOR SUPPLIED BY BENCO DENTAL. INSTALLED BY CONTRACTOR. THIS WORK TO BE DONE BY THE PLUMBING CONTRACTOR. NOTE: ACTUAL UNIT MAY VARY FROM DESIGN SHOWN, SEE MANUFACTURER'S 1114C)IMLLMHU114 VuluL. COPPER LINE OR EQUAL TO ALL DENTAL EQUIPMENT REQUIRING A COLD WATER SUPPLY. T1 PLUMBER IS TO VERIFY THE EXACT LOCATION OF THE WATER CONTROL VALVt ANU �ILItK ASSEMBLY WITH THE DOCTOR/OWNER, AND A BENCO REP AT THE TIME OF LAYOUT AND PRIOR TO EQUIPMENT SELECTION. SHUTOFF VALVE BEFORE WATER CONTROL VALVE AND FILTER ASSEMBLY WATER CONTROL VALVE AND FILTER ASSEMBLY SUPPLIED BY BENCO DENTAL MINIMUM OF 6" CLEARANCE REQUIRED BELOW FILTER FOR CHANGING OF FILTER CARTRIDGES. Y2"O COMPRESSED AIR UNE. X" MALE PIPE THREADS 1" FROM WALL, %" ANGLE STOP VALVE, CHROME COVER NOTE: VERIFY QUANTITIES & LOCATIONS WITH DOCTOR AT TIME OF LAYOUT. COLD WATER SUPPLY W/ %" ANGLE VALVE STOP WITH ESCUTCHEON MODEL TRIMMER EXACT LOCATION TO BE DETERMINED BY OWNER PVC ADAPTER SUPPLIED WITH TRAP FLEXIBLE HOSE SUPPLIED WITH TRAP DISPOSABLE PLASTER TRAP NOTE: CAPS SUPPLIED WITH TRAP ARE FOR TRAP DISPOSAL, DO NOT DISCARD Om DETAIL - AMALGAM SEPARATOR 05 1 DETAIL- WATER CONTROL VALVE 06 1 DETAIL- TYPICAL AIR OUTLET 07 DETAIL - MODEL TRIMMER / PLASTER TRAP 08 1 REF.: SOURCE: N.T.S. I RE F.: SOURCE: N.T.S. I REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. FLOOR VACUUM LINE. Y2"ID STUB. SEE DETAILS 03 & 04 ON THIS SHEET. DRIVE GAS/DENTAL AIR LINE. Y2"ID STUB W/-Ys"OD COMPRESSION VALVE. DRAIN — 1Y P—TRAP IN LINE TO CONFORM WITH LOCAL BUILDING CODES. COLD WATER LINE. Y21D STUB W/ 3/s"OD COMPRESSION VALVE. HOT WATER LINE. Y21D STUB W/%"OD COMPRESSION VALVE. *NOTE: SEE MANUFACTURER'S TEMPLATE FOR EXACT ROUGH —IN LOCATIONS. r ............. i r- — — — — — — — — — -- N, ---------- li it DENTAL COLD WATER LINE. Y2"ID STUB W/ 3/8"OD COMPRESSION VALVE 4" A.F.F. COMPRESSED AIR LINE. ;V2"ID STUB W/%"OD COMPRESSION VALVE 4" A.F.F. '*'—ORAL VACUUM LINE. ),2"ID STUB 4" A.F.F. *NOTE: SEE MANUFACTURER'S *NOTE: SEE DETAILS 03 & 04 TEMPLATE FOR EXACT ROUGH —IN ON THIS SHEET FOR VACUUM LOCATIONS. PIPING REQUIREMENTS A VACUUM LINE — REDUCE RISER TO X" COPPER PIPE. TERMINATE STUB AT 2" A,F.F. SEE DETAILS 03 & 04 ON THIS SHEET. DRIVE GAS/DENTAL AIR LINE — X" COPPER LINE WITH X" ANGLE STOP AND V COMPRESSION FITTING. TERMINATE STOP NO HIGHER THAN 4" A.F.F. *NOTE: SEEE MANUFACTURER'S TEMPLATE FOR EXACT ROUGH —IN LOCATIONS. DENTAL COLD WATER — X" COPPER LINE WITH X" ANGLE STOP AND %" COMPRESSION FITTING. TERMINATE STOP NO HIGHER THAN 4" A.F.F. DETAIL- STERILIZATION CABINET PIPING 09 DETAIL- TYPICAL REAR CABINET PIPING 10 DETAIL - TYPICAL UTILITY CENTER 11 DETAIL 12 REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T,S. DETAIL 13 DETAIL 14 DETAIL 15 DETAIL 16 REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. ImAftAmAtme PRACTICE AM11MU I SOLUTIONS PITTSTON,PA - DALLAS TX - COSTAMESA,CA 1 . 8 0 0 . 4 6 2 . 3 6 2 6 / 8 E N C 0. C 0 M 0 HermanMitter NE E E 0 cn Jc .j LL 4.4 cu 0 ISSUED: DATE: ZONESTUDY MMIDD/YY DESIGN SCHEMATIC 07/07/21 DCD (FOR REVIEW) 07/23/21 DCD MM/DDIYY PROJECT# C121070-RL DRAWN BY: f REVIEWED CHECKED BY: OTHERS,RL TH DRAWING TITLE: DENTAL PLUMBING DETAILS SHEET: Q4.2 I$" Date 09-03-21 Midmark Quotation 6�b midmark- "d k, Terms & Conditions mi mar ProJect Information, Ndmork Rep Informaillon: Designer InIbrmatlow Project Name., Premier Zyphyrhflls P1`0*Ct Rep: Scott E Smith Designer. Antrurn Stewart txt: 128743 Midmark DraWings Ptoject#:DS211512 Phase.-Ol Rev:2 Emall.-Sesmith6midmork-com Ernal:astewort@rnidmork.com Agreeml Dental 2021 Synthesis Pricing Phone: 1-800-MIDMARK Project No -me: Premier Zyphyrhills Mildmark Order Policy Shipping and Receiving Policy - Order will not be sent to scheduling until a purchase order, signed Cabinetry Packaging: - Cabinetry accessories and equipment w0l be drorvAng and field measurements (if applicable) are received. boxed. Project DS211512 - Installation is not included unless noted otherwise. Orders shipped via common L71- carrier or full truckload carrien. - Taxes and plumbing hook-ups are not included in the pricing, Please specify your preferred delivery dote, Phase: 01 - Order needs to be placed with an authorized Midmark distributor. - Pref erred delivery, date is not guaranteed based on tAidmork lead time. Order Changes and corrier's avollabl[ity. Rev: 2 - Please specify if delivery site is NOT able to accept delivery on a - AN changes should happen before the receipt of the order, full-size, 53' truck and trailer, - Order changes made after receipt of an order may incur a change fee Date.- 6[2812021 - Report any damaged goods or short shipments to the freight comer and and a shipping date change. This fee win cover motericts, labor. and contact Midmark Corporation immediately. handling costs, Project Rep.- Scott E Smith - Please specify if rift gate is required. - All changes must be submitted in writing. Upon review and opproval - Orders ship per the policy on Re, of changes, ft order will be moved to the next available ship dote. sesmith@mid.m-or,k.com Delayed/Rescheduled Ship Dates Lead Times Designer Antrum Stewart Ext: 128743 - Request to reschedule orders that ho-ye not bten b - Ccbnetry lead rime on standard items on d color " weeks" , � I uilt wol be Moved EquipmentYWork4tati&A lead time: 1-3 weeks" to the next available ship date, - Request 10 reschedule or delay shipment of orders that hove been built Cobine try lead time on Artizon, custom colors: 6-10 weeks" astewart0midmark.com vvill incur storage andhandling fees until sKipped. "te, ad times are subject to change based on volurne and quah"es Phone., 1-800-MIDMARK Order Conce4fallon - Cancellation 48 hours from time of order placement is subject to penalty. An assessment will be made of time of cancellation to determine the amount of penalty including material, labor and handling costs, - Conceflations must be received in writing. Non-standord color ond custom configuration orders may not be cancelled without penalty. Return of Merchandise Custom Cobinetry and Workstations are built -to -order and are These drowings are the sole property of NUdmork Corporation and ore to be used few Illustrafflon only. Actual product appearance may vary. non -returnable, Me: PI lyphyrNk M111512 Phose 01 Rev: 2 Signed Drawings Required To Approvals Project Name: Premier 2yphythilis Project 6Z;6 Process ordef midmark #., D5211512 midmark Phase: 01 Rev: 2 Floor Plan View wwwMtjmork.com design Oft'Ornork.torn I acknowledge the folloming for all applicable pages, Phone: 1-800-MIDMARK Approv0d Revis!pd to Reflect Colors & Finishes VK 6L 7! -T ........... Configurations, Sizes& Field, Measurements Terms, Conditions & Delivery Instructions Signature Date I lip Cabineiry Countertops Panet Styles.- Cove Materials: Solid Surface jp �'k, H, J AMA -!DotI TOD SoNd Surface TBD WoocRZcin/Mekad -ICA- Sold 5urface c <V/ r (--tAWnr1r nrnwbrol Tw"NMP, ?n-79-F0.nMJA 4-1 (D 0 h- Q CIO Cc co LL ZZ 21 U- :) E C: 0 M 0 F- 0 00 0 CO 0 E L) C cu -0 L- 0 0 LL Ui > 0 0 W N (D 0'r 0 L) 4-1 0 C U a) CN M E cr*o— CD Job Nuffdxw 2008 Revisions A � A Sheet No. MDK-1 TT issue Date 09-03-21 - I . -- - --- � -1. --- , , -, , .. - z- -, -N 4� FAq t:l wf�vlwln, f- I rrrXV'AA9A V19 Lob Project Name- Premi4er Zyphyrhoh P"ct #� 03211$12 Pho$V- 01 Rev� 2 Note: AN local. AM-.. cTd led. it -rJ —,%-t x V . . . . . . . . . . . . . . . . Rpviltimnl r-I 30M =,I be used fOr Illustration onty. Actual product oppearance MOY VOTY- Wi is 0. #11 0 UPIP01WOft I OD-76D Woo<JgoirVMetcdfic pooa� Style- Cove Panel Mande: None, Lock: No Lcck Lob (--LPv.4rwk r)rn"rws Tftnv-Jnfn- 9n-MFn-ffWI],r4 1 ��Miii 1111001, 0 M MW EMMA- *11 Op I No Sink Side (Qty: 1) r7n"Awfvp rlfmwinrl r.-MnJntf- P"e,O 0, DS211612 Ph= of Rev: 2 Signe-d Drawings Required To Oss ar Inck4ed TCO Motenck. Solid sugace AC2Z04O& AC27.OM I � Top Coke', TOD Sobd Surfoce None Note: USXA620�,AAW-162D-Al (MY-A-� Maw) 1��- ot- CfT-OCHGSMLL Iris SS99 BM3 A803 .()Cr --- I — 24.W,___;_ IT- 24W 27.W 148,00' RPVWnn- r- I 8MBFb*K IM-MOWOOdgrvinIMetaKc Tosftht: Uppat rhw-. Groff Vnef FOAM Sye, Cove Ponel Ultrasonic- Hondw NOM Note: Lock: No Lad W% An D%w 4in Dwr An Dwr 8in Dwr I Rol 0 1 80" 1 Project 4: DS211512 Phose 01 Rev: I Signed MmWn93 Required To Process Order None Top Motfticd-, SOW Surface None Top Com TBO Sob SLWorze Mme Note: SirWFaucel not include-4 -711 IDZ) i Sink.; mom MOW) FOLPC-et- NOM See COOMOMP SvIfoce C � ftMd Edge wl Int BS 0. $1 x Z S4 ROVItk)n- F1 (3 (D CO 0 'D .0 .,,,o LL Z (a 7 0. LL L) E C M W F- W CO 0 CO 0 C; M CO 0 W (3 C CU 0 0 L. .0 CU 0 U) > 0 1E L) r CD CU U) (1) 0 CU 0 C: 2 E E CU 0 C Job Number 2008 Revisions A FAI FAI Shoot No. MDKm2 Issue Date 09-03-21 ,6�6 midmar www,rl ridmo&coff 4 .94 Op I Sink Side (Oty: 1) rnr owmi, nrnwinn To Proiecf Nomw Premkir Zlyphyrtillis RoseFinish' 1MTBDWo&dgroin1M,,10fC Uppelfi,flisK, 5100-T9DW0odWoh/Mef0*C Tionel Style- Cove PwO4 Honda: N*ne'i Lock� No Lmk, 3().W'------7r24.C(Y'------.Yl I �— OA23 OA23 'I 4in DvYr 4in Dwr Trash Can 8in Dwr No= B020 I if 30-Wf Project #, DS211612 Phase Of None Top Mde": AC22.0406 TCP Cokx-, None "0: Sint: Signed MOVAngs Required To Process Order Faucet-. CPA-PNIMSPS-1, Prolisci Norne: PrenIer Zypbyrhgls Projed DS211512 phMe 01 Rev, 2 Signed Drawfings Required To Process Order I MTRDWoodgroWMelcific TestA)ht, None Tor-, Moleriol- Sofid Suface midmark prwFoor Panel SW Cove Ponef &MWT*t-. N6AL% Uflrasonic� Norte Too Cd�m! TRD S o#d Sutloce Note: $**Aoucet not inckided www,midrnorkxom Honde: None Nole: NCAW (000) Ftwne-. I MD-tWDMARK Lock,' No Lock Note', Ops 2-4 Side Cobs (Qty: 3) 41n DwT 4in Dwr 4in Dwr Bin Dwr 1 8020 1 B099 I R009 I wp,vk.ir%n, F1 MINTO �75 =-Mfl� 4 6% midmark wwwmidmorCcorn "ect Nome- Premier zyptwhms Project #: 0&211512 Phose 01 Rev, 2 a -1 J1FATAV1'tr,-NW be usad fo(Mustroflon onty- Actual prcxlvct appeorance MOY Vory, Wate: AN k A & nht 11 lf�-. IL - - Op I Sink Side (Oty: 1) r1rnwinn TAmnlntp- ?M7)-F04MJ 1; &b midmark wwwmidmatit.com Sten, r,rtum"e,w* Mo�v Rovkinn- F1 Bose FiMk I MT8D woodgrdn/metc&-_ Upper FMh-. I MIRD W66dgmirklMefotc Pcir�w Sw: Cove Pcmej I Handle* Lock.- No Lock �-t U I risks -2TW- - 24W Je 24.W yy VAN 0 IMP Signed Drowings Required To Process Ordw Intkided 1*0 M&,eno;: None Top co&x: None Note' Sink� See COVM10015 00ftif Shetl:Sofid Surfoce F , Ro" Edge w/ Set -On BS 0,5'x 2Z' d C 4- (D U .0 >: 2 3: _J N < 1: LL Z (C -J z C. LL :) E C 0 M to '0 — N (D OD 0 W d CU C:L 0 C 0 r .0 (U > -C 0 C: C13 C.) CL N CU U) 4— 0 cu 0 () C: C/) 75 E E CU 0 4-J C E n Job Number 2008 Revisions zn� ZL ZL ,%eet W. MDK-3 Issue Date 09-03-21 Project Nome., Prenier ZyphyrhMs Project U: DS211512 Phow 01 Rev: 2 ��wu� =114k � IMMU 1111111111 i w v! Phorw- I -WD-MIDMARK VXTIOW-1 lw I I'll - � ErMT., be used fwillwtrallon only, ACtUd prodoCt oppearome May VCrY. ME 11C MIMIlm N-o""MAIM SAID Proiect Nome, hemlet Zyp"hft Pwoject C W211-612 Phase Of L'23-W—� Mckided Top Mclefk3l' Ven, WICWed 70P Czxw, Not kx*4ed X-Ray shlefdk1w Nol b-�ckx:k--d Sink-. NDI lmhoded Faucet- sted ITS (Qty* 4) r—swwm, mewimn Tprn"ntift- 9M77-RJ4MJ,5 f?fq%ifdfIn- F) Frrgv,,ugn IV.19 I I r.ei,�-wrvk nrmAkws 1p.motntp- 90-77,504M] -5 1?0.vkinn - Fl Ar.rprAulofl 14/19 Profeq--f Nome: fteniozymiwT%w Project OS211512 Phose 01 Rev: 2 S19fted DmWkVi Requked to Bum,- RnAft I 00-IRD Wbodqtoir4NAefc&c lbskgghk fWuded Top Moterk*., ho�cess Order midmark, Accallt FWMI I M110 Woc47drVMetaft CJMJ Vent. Yent Indudea Top Cobc TBD ScOd Sutfme Pane4 Slyie., covepaneA Pfocenter mounf-� Not InCtuded X-RCY V"dflg� 1 Not Inchoded' -1 -7 W. 7 W2% None Nhot* mount: N*t IfKAided Sft: Mome Phone: ).=-MIDMARK Lock", No Lock LAB Hub Moutt Nol Wcludaa FGucet'. TS (Qty: 4) (-"I-wn* nrmvAnn Tamnints- n7'?-F04MIA 42.5T I -- I I?Pvkinn- F I Lim 53 * =A- Nut 2 F?l.(lA&luVn 14% � 19 VNN E , TS PWS Only (Oty, 4) Name: ftwwor zyoyrhift kpvKinn - F I Rm��E phose 01 Rev; 2 sts"ed Drawings Itectwre4 To Proc4w Orde�r lS36S9-M wwksvrtmopum "&uftthwuwwf*0pu0m Suppimt None TOIX (Starodand) - Codon Top Frnn&uqn -71-112= t (DOW W19 Co V) (00 m 0 E) CO (0 -J LL a) Z M 7 0. LL 3 E C: 00 Co 0 m U) a) 00 m 0 C Cu 70 C/) L- 0 C .0 4-J Cu > -C 0 >% C- CL fy U) mr :3 Cu >S 0 (.) C) C CA 4-a E E Cu 0 1-i C CN E Job Nunber 2008 Revisions A I ml ME Sheet No. MDK-4 left Issue Date 09-03-21 -r I - 6 K�N At Design Considerations.- * Tops thot exceed I "'or form an I" or "U" shape will be sent as multiple pieces and require field seaming by a qualified solid surface fabricator. * Integrated and undermount sinks and chutes will be attached. * Sink and faucet cutouts provided only if sink and faucet are purchased from midmark. * Tops vAll be manufactured based on the field measurements provided at the time of order. Tops may be sent long. See elevations for exact countertop width. * Side sp4ashes next to tall towers ond drop down ultrasonic areas will be nonwrapped (see detail drawing). * See color guide for standard color options. Confirm availability for nonstandard color options. Extended lead timewill apply, Material: * I /Z'thick solid surface material. Features: * Outside corners of solid surface tops Will have 3/8!'radius, * Standard countertop overhang for base cabinets is 1/2". Integrated solid surface, sink will be Glacier White. Loose set on side splash available. f-_. n-4-:1 �n " CC rvv�nA Solid Suftce Detal C Integircited Backsplash 0.6'x 2.5" Detail drawings: See Side Elevofion 0.5 4. 2.5 0-375' R Counfertop Detail R Wrapped Side Splash Detail Wrapped Side Splash Side Splash Front Detail Front Edge 3D Non Wrapped Side Splash Detail Nonwrapped Side Splash Side Splash & Front Edge 3D Backsplash 3D r%-4—� - 0-211co 17110 Grommet Detail Sheet Lamirtole counteriop, Grommet is a separate pad, it vvill be o One item in the pricing. midmaa�k Corian cQiintertop; Part of the countertop � Yes. grornmet is part of the counlwtop: it wig not have a line item in the p(icing. Pcwt of th counterlop = No, 91-Ommet is 0 separate port; it vAl be a line item in the pricing, Waste Grommet AC20,0601 AC23.0401 AC23.0601 AC28.0602 Cok:)r: Block Sljze� 6in opening Color: Black Color: Block Color: Stainlass Steel Pad of a Colion countertop: No Size: 41n opening Size: 61n opening Size. 5.375in opening Includes Trash Con Pori of a Corian countertop: No I Part of a Corian co unterfop: No Part of a Corion countertop: No Waste Chute Sharps Drop AC21.0406 AC21.06" AC22.0406 AC22.0606 AC29.0406 Color White Color: White Colm White Color: White Color White Size: 4in opening Size: 6in opening Size: 4in opening Size: 6in opeWing Size: 4in opening PCIrt of o Corian counterfop--,�es Part of a Corion countertop.- Yes Pail of a Corion countertop, Yes Part of a CQrion coVnte rtop; Ye� Part of o Corian counteitop: Yes Wire Grommet AC24.0201 AC2S.01 01 AC26.0101 AC27.0201 cotor'. Putty Color: Block Color Pulty Color Block Size: 1.625in opening Size:.5625in opening Size-, 5625in opening 5ize. 1.6251n operting Port of a Corion counterlop: No Tart of a Corion covntertop: No Part of a CcOon countertop, No __[Port ofa Corion countertop: No -----^4 n,#-jj 'M 7q DC r.'V�A7 �- I Design Considerations: * Tops that exceed 144'or form an 1" or "U" shape vAll be sent as multiple pieces and require field seaming by a qualified solid surface fabricator. * Integrated and vndermount sinks and chutes will be attached. * Sink and faucet cutouts provided only if sink and faucet are purchased from Midmark. * Tops will be manufactured based on the field measurements provided at the time of order. Tops may be sent long. See elevations for exact countertop width. * Side splashes next to tall towers and drop down ultrasonic areas will be nonwrapped (see detail dravAng). I See color guide for standard color options, Confirm availability for nonstandard color options. Extended lead time will apply. Material: 1 60IMim, M bm- MTN Solid Surtace Detcli IF Set -On Backsplash 0.5" x 2.r Detail drawings: See Side Hevation D.5 2's 4. 0-25' 4-- R 0.25' Countertop Detail 117'thick solid surface material. Wrapped Side Splash Detail Wrapped Side Splash Side Splash Front Detail Front Edge 3D Features: * Outside comers of solid surface tops will have R LOW 3/9'radius. * Standard countertop overhang for base cabinets is 1/2'% * Integra led solid surFace sink will be Glacier White. * Loose set on side splash available. Non Wrapped Side Splash Detail Nonwrapped Side Splash Side Splash & Front Edge 3D Socksplash 3D n-4-3 C3"--#- -.n -7n 0c: rVIAn'. A I r-t— -- - I—V'040 ISUIQ 6 C rD 0 -j LL Z Cc Z 0. tL C Co (0 � (D co N 0 0) U) 0 ry moo (3 C/) 0 C 0 0 [Z CU cli > 0 CZ C— cL W N (D A-0 CU U) (1) 0 2: 4-- 0 C Cn E E CU 0 a) 4-a C 35; Job Nuffbw 2008 Revisions A Sheet No. MDK-5