HomeMy WebLinkAbout5349 4th StPROJECT TEAM VIOMA LORENZO. P.A. OWNER 4202 W. GREEN ST. TAMPA. FL 33607 OPTIMUM PLUMBING, LLC. CONTRACTOR 5406 LAND 0 LAKES. BLVD LAND O' LAKES. FL 34639 NICOLAS MENDIETA, P.E. PROJECT MENDIETA STRUCTURAL CONSULTING, INC. ENGINEER 3721 BELLEWATER BLVD. RIVERVIEW, FL 33578 LICENSED JAVIER GOMEZ ELECTRICIAN EC13009619 & CAC1817440 SHEETINDEX SHEET NO. SHEET TITLE B001 COVER SHEET B002 EXISTING & DEMOLITION PLAN B101 PROPOSED FLOOR PLAN B102 WALL SECTIONS B201 EXISTING ELEVATIONS B301 PROPOSED ELEVATIONS S001 STRUCTURAL NOTES & WIND PRESSURES S101 ROOF FRAMING PLAN & SECTIONS E101 ELECTRICAL PLAN PROPOSED RENOVATION FOR: INTERIOR REMODEL 5349 4TH STREET ZEPHYRHILLS, FL 33542 VICINITY MAP SCALE: N.T.S ALL C(p SORK SHALL CO AND -r,,E 9 OR C `D NCY, Cd ERREVAIL�NG 9�RI�t �� GIIy or zgp OdE. ,. C //r�°`' pLqN �RNyR�� M�N�•R CL PROJECT INFORMATION: LOCATION: 5349 4TH STREET, ZEPHYRHILLS, FL 33542 PARCEL ID: 11-26-21-0010-09600-0010 TAX DISTRICT: CITY OF ZEPHYRHILLS OCCUPANCY: SINGLE FAMILY BUILDING AREA: 959 SF FLOOD ZONE: X PROJECT SCOPE: 1. INTERIOR REMODEL. 2. RELOCATE BEDROOMS AND BATHROOM. 3. REPLACE EXTERIOR WINDOWS/DOORS. 4. ADD NEW AND INFILL EXTERIOR OPENINGS. 5. NO CHANGES TO SETBACKS. APPLICABLE CODES: • 2020 FLORIDA BUILDING CODE (SEVENTH EDITION) • 2020 FLORIDA BUILDING CODE, RESIDENTIAL (SEVENTH EDITION) • 2020 FLORIDA EXISTING BUILDING CODE (SEVENTH EDITION) • 2020 FLORIDA BUILDING CODE, ACCESSIBILITY (SEVENTH EDITION) GENERAL NOTES: 1. ALL DESIGN AND WORK TO BE PERFORMED BY A LICENSED ENGINEER OR CONTRACTOR AND COMPLY WITH APPLICABLE CODES AND ORDINANCES. 2. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE STARTING ANY WORK AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. 3. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 10 & AS DIRECTED BY THE FIRE MARSHALL. 4. CONTRACTOR SHALL COMPLY WITH LATEST OSHA REQUIREMENTS. 5. MANUFACTURED MATERIALS SHALL BE INSTALLED PER THEIR PUBLISHED INSTRUCTIONS. CONTRACTOR SHALL GIVE ACCEPTABLE CERTIFICATES OF INSURANCE TO OWNER PRIOR TO BEGINNING ANY WORK UNDER THIS CONTRACT. 6. CONTRACTOR SHALL SECURE A CERTIFICATE OF OCCUPANCY FROM THE GOVERNING AUTHORITY AT THE COMPLETION OF THE WORK AND GIVE IT TO THE OWNER PRIOR TO FINAL PAYMENT. 7. A COMPLETE LIEN RELEASE AND CONTRACTORS AFFIDAVIT WILL BE GIVEN BY CONTRACTOR TO OWNER AT TIME OF COMPLETION. 8. ALL WORK SHALL BE GUARANTEED FOR 12 MONTHS AFTER ISSUE OF CERTIFICATE OF OCCUPANCY. 9. PROVIDE BLOCKING IN WALLS BEHIND ALL WALL MOUNTED FIXTURES AND ACCESSORIES. 10. USE MOISTURE RESISTANT GYPSUM BOARD BEHIND WALL WALL TILE (IF APPLICABLE). 11. PROVIDE CAULKING AND SEALANT AS APPLICABLE. 12. VERIFY SIZE AND REQUIRED CLEARANCES FOR AL EQUIPMENT, APPLIANCES, AND CASE WORK PRIOR YO INSTALLATION. ADJUST MILL WORK DIMENSIONS AS REQUIRED 0 ENSURE PROPER FIT. 13. VERIFY SIZE AND REQUIRED ROUGH OPENING DIMENSIONS FOR ALL DOORS AND WINDOWS. I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES Drawn by: NM Checked by: NM Issue Date: 03-15-2021 Project Number: 21-004 Revisions: A U N O n W O N d' � ccoW c�'� LI U) .J O Cy') = W W N `— Z LI) u7 C'7 QU J 5C � G w -i LLJ _JQ J = L.L. W U Z� � o W J WU) LU `� ENs� No.8 62 y: _o•• T �441; ENGINEER OF RECORD NICOLAS MENDIETA FL P.E. # 86662 FIRST FLOOR PLAN, WINDOWS/DOORS SCHEDULE i 1 1 0 M = 1'-0" ,2c, nil ITION PLAN U Z J Q � Z HF--J _W 0 -5 U) Z W Z M � O I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAVVINGS AND SPECIFICATIONS COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES Drawn by: NM Checked by: NM Issue Date: 03-15-2021 Project Number: 21-004 Revisions: r c a_> U W 0 ON IW M W W ,L (1) J O MLO = W W F— Z Q It It M QU J LL �W W �oa J Q �LLL U ZIq o W WJ �r Mr W No.86 2 T E O R ,� • . '`� . C� ' 0 ENGINEER OF RECORD NICOLAS MENDIETA FL P.E. # 86662 EXISTING & DEMOLITION PLAN DOOR SCHEDULE MARK SIZE STYLE MANUFACTURER PRODUCT APPROVAL 1O 71J"x81�" SLIDER PLYGEM WINDOWS & DOORS FL15297.1-R8 O36"x81? SWING DOOR JELD-WEN FL11136.1-R9 WINDOW SCHEDULE MARK SIZE STYLE MANUFACTURER PRODUCT APPROVAL 1O 36"x49t" SINGLE HUNG PLY GEM WINDOWS FL14039.1-R6 2O 36"x25" SINGLE HUNG PLY GEM WINDOWS FL14039.1-R6 O3 52�'x50" SINGLE HUNG PLY GEM WINDOWS FL14039.1-R6 WINDOW & DOOR NOTES: 1. DIMENSIONS SHOWN ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO INSTALLATION. CONTRACTOR TO CONFIRM OPENING SIZES WITH MANUFACTURER AND PRODUCT APPROVAL REQUIREMENTS. 2. INSTALLATION SHALL BE PER PRODUCT APPROVAL AND SHALL MEET WIND PRESSURES SHOWN IN STRUCTURAL DRAWINGS. 3. CONTRACTOR TO VERIFY ALL PRODUCT APPROVAL NUMBERS. 0 co 0 ih 9, 4T3i.0 PROPOSED FLOOR PLAN (?) PLAN NOTES: 1. DIMENSIONS SHOWN ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. 2. ® INDICATES A 2x4 LOAD -BEARING WALL. 3. INDICATES A 2x4 NON -LOAD BEARING WALL. 4. = INDICATES WOOD STUD INFILL, SEE STRUCTURAL DRAWINGS. 5. CONTRACTOR TO PROVIDE FLORIDA PRODUCT APPROVALS AS REQUIRED. 6. SEE SECTION 1B102 FOR WALL SECTION AT EXTERIOR. 7. SEE SECTION 2/13102 FOR WALL SECTION AT EXTERIOR WITH OPENING. 8. SEE SECTION 38102 FOR WALL SECTION AT INTERIOR LOAD BEARING WALL. 9. SEE SECTION 4/6102 FOR WALL SECTION AT INTERIOR NON -LOAD BEARING WALL. U Z J � Q Z LU J _W F_ 07 Z Z LU M U) O F14, I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES Drawn by: NM Checked by: NM Issue Date: 03-15-2021 Project Number: 21-004 Revisions: c m U J W 0 0 N W ccei WALL •) J O cM = w W N Z Q Lf) v 1 M QU �W W �oa J Q W[f U Z`t >- o W J WT�W i M OEIVSF' ��`X' No. 866 2 F J" ENGINEER OF RECORD NICOLAS MENDIETA FL P.E. # 86662 PROPOSED FLOOR PLAN B101 MR EXISTING ROOFIN( TO REMAII EXISTIN( FLASHING T( REMAII APA RATED EXTERIC PLYWOOD, SE STRUCT. SHEET VINYL SIDING TO MAT( EXISTING INSTALLED OVER NE FELT PER MANUFACTURE SPECIFICATIONS (DUPOP TYVEK HOUSE WRAP OR EQUA 1 EXT. WALL SECTION �O2 REF: B101 SCALE: 3/4" = V-0" SIMPSON TIE, SEE STRUCT. SHEETS TRUSS BRG.I EL. VARIES, VIF. R-30 BATTERED INSULATION " THICK GYPSUM SHEATHING DOUBLE TOP PLATE, SEE STRUCT. SHEETS FOR MORE INFORMATION " THICK GYPSUM SHEATHING CONT. BLOCKING, SEE STRUCT SHEETS 2x4 WOOD STUDS AT 16" O.C. MAX. R-13 BATTERED INSULATION PT2x4 SILL PLATE CONT. SEE STRUCTURAL SHEETS FOR CONNECTOR INFORMATION EXISTING FLOORING TO REMAIN FINISHED FLR. EL. 0'-0" EXISTING ROOFIN( TO REMAII EXISTIN( FLASHING T( REMAII APA RATED EXTERIC PLYWOOD, SE STRUCT. SHEET HEADER, SE STRUCTUR/ VINYL SIDING TO MATC EXISTING INSTALLED OVER NE FELT PER MANUFACTURE SPECIFICATIONS (DUPOP TYVEK HOUSE WRAP OR EQUA 2 EXT. WALL SECTION �O2 REF: B101 SCALE: 3/4" = 1'-0" SIMPSON TIE, SEE STRUCT. SHEETS TRUSS BRIG. EL. VARIES, VIF. R-30 BATTERED INSULATION �' THICK GYPSUM SHEATHING DOUBLE TOP PLATE, SEE STRUCT. SHEETS FOR MORE INFORMATION " THICK GYPSUM SHEATHING SILL, TBD 2x4 WOOD STUDS AT 16" O.C. MAX. R-13 BATTERED INSULATION PT2x4 SILL PLATE CONT. SEE STRUCTURAL SHEETS FOR CONNECTOR INFORMATION EXISTING FLOORING TO REMAIN FINISHED FLR. EL. 0'-0" EXISTING ROO-"'- TO REI 3 INT. WALL SECTION B�O2REF: B101 SCALE: 314" = V-0" TRUSS BRG. EL. VARIES, VIF. R-30 BATTERED INSULATION I" THICK GYPSUM SHEATHING DOUBLE TOP PLATE, SEE STRUCT. SHEETS FOR MORE INFORMATION �' THICK GYPSUM SHEATHING, BOTH SIDES CONT. BLOCKING, SEE STRUCT SHEETS 2x4 WOOD STUDS AT 16" O.C. MAX. 2x4 SILL PLATE CONT. SEE STRUCTURAL SHEETS FOR CONNECTOR INFORMATION EXISTING FLOORING TO REMAIN FINISHED FLR. EL. 0'-0" EXISTING ROO-'-- TO REI TRUSS BRIG. EL. VARIES, VIF. R-30 BATTERED INSULATION J" THICK GYPSUM SHEATHING TOP PLATE CONT., WITH SLOTTED VERTICAL CONNECTIONS TO JOISTS " THICK GYPSUM SHEATHING, BOTH SIDES 2x4 WOOD STUDS AT 24 O.C. MAX. 2x4 SILL PLATE CONT. W/ 10D NAILS TO FLOORING AT 12" O.C. MAX. EXISTING FLOORING TO REMAIN 4 INT. WALL SECTION B102 REF: B101 SCALE: 3/4" = V-0" FINISHED FLR. EL. 0'-0" Z Q Z LU~5 0 U) ZWz M � O I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES Drawn by: NM Checked by: NM Issue Date: 03-15-2021 Project Number: 'o a 21-004 W 0 O" LW c WXLL U) ( O 1 _ a w W N Z Q 't L0 1 M �WW ` 0- rJ Q �Cz U zIT} ow J W w PS ME/V ... GENSF • ), .'s • No.866CC E ENGINEER OF RECORD NICOLAS MENDIETA FL P.E. # 86662 WALL SECTIONS B102 EXISTING SOUTH ELEVATION SCALE: 3/8" = 1'-O" EXISTING EAST ELEVATION SCALE: 3/8" = 1'-O" 12 EXISTING NORTH ELEVATION SCALE: 3/8" = 1'-O" EXISTING WEST ELEVATION SCALE: 3/8" = 1'-0" U Z Q � Z LU F F- LU ID U) ZLlLJ Z M U) OO I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES Drawn by: NM Checked by: NM Issue Date: 03-15-2021 Project Number: 21-004 Revisions: a J W 0 0 N 'd' 2 W M Wof� Io J O M = ix w W N Z Q I' LO co QU J IL GW W �oa J Q �[U Z-} oW J Wow °%.SM�/1''' ,- O . •• DENS � �,-- -� V V F ' c �. .•.y No. 86 E� cc? OF • ` W = =,gyp ' ,••''�C oR`QQ, ; �`��,,= ENGINEER OF RECORD NICOLAS MENDIETA FL P.E. # 86662 EXISTING ELEVATIONS B201 ITH ELEVATION = 1'-0" PROPOSED EAST ELEVATION SCALE: 3/8" = 1'-0" 12 PROM SCALE: 3/8" = 1' PROPOSED WEST ELEVATION SCALE: 3/8" = 1'-0" 1, I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES Drawn by: NM Checked by: NM Issue Date: 03-15-2021 Project Number: 4) 0 a 21-004 J W 0 0 " LW ccfi Www U) J O M = w W N Z Q IV I' LID QUA LL �W W ` 0 � rJQ U Zg w O J WvW M�!Vd'''-, N 662 ' ?t • T OF NICOLAS MENDIETA FL P.E. # 86662 PROPOSED ELEVATIONS B301 SP1 AT EACH STUD FLOOR FRAMING BELOW EXISTING DOUBLE TOP PLATE. REPLACE EXISTING CONNECTIONS TO ROOF RAFTERS IN KIND OR PROVIDE (2) H2.5A CONNECTOR AT EACH RAFTER SP2 AT EACH STUD CONT. BLOCKING AT MIDSPAN W/ (2) 10d TOE NAILS AT EACH END. EXISTING SINGLE SOLE PLATE. WHERE PROVIDING NEW SOLE PLATE, ATTACH TO FRAMING BELOW WITH DIA. LAG SCREWS AT 8" O.C. 1. PLYWOOD SHEATHING, IS NOT SHOWN FOR CLARITY. 2. SEE WOOD FASTENING SCHEDULE FOR MINIMUM NAILING REQUIREMENTS. STUD INFILL DETAIL OF EXISTING OPENING SP4 AT EACH KING STUD WRAPPED OVER TOP PLATE. KING STUD(S). MSTA12 AT EACH END (1) JACK STUD AT OPENINGS T-0" WIDE OR LESS. (2) JACK STUDS AT OPENINGS GREATER THAN T-0" WIDE. H6 SIMPSON STRAP TO FRAMING BELOW AT KING & JACK FLOOR FRAMING BELOW SCALE: NTS DOUBLE TOP PLATE. SEE PLAN NOTES. SP2 U.N.O. ON PLAN. CRIPPLE STUDS TO MATCH WALL STUD SIZE, SPACING AND ATTACHMENT TO TOP PLATE. HEADER BEAM. SEE PLAN AND PLAN NOTES. (PLANK INDICATES ROTATED 90 DEG.) MSTA12 AT EACH STUD, U.N.O. ON PLAN. 1. PLYWOOD 5HE:ATHING, IF APPLICABLE, 15 NOT 5HQVVN FOR CLARITY. 2. A MINIMUM OF (1)JACK AND (2) KING STUDS ARE REQUIRED AT ALL OPENINGS, UNLESS NOTED OTHERWISE ON PLAN. 3. WHERE MULTIPLE JAMB STUDS ARE SPECIFIED EACH JAMB STUD IS TO BE STRAPPED WITH MSTA 12. 4. NAIL JACK & KING STUDS TOGETHER WITH 10 NAILS AT 8" O.C. STAGGERED EACH SIDE. 5. AT WINDOW OPENINGS, PROVIDE 2x SILL PLATE WITH 3-16d TOE NAILS TO EACH JACK. TYPICAL STUD WALL OPENING DETAIL SCALE: NTS STRUCTURAL NOTES These drawings are to be used in combination with job specifications and architectural, mechanical, electrical, plumbing, and site drawings. Consult these drawings for sleeves, depressions, and other details not shown on structural drawings. Do not scale these drawings for dimensions not given. Advise project architect of any conflicts between these drawings and the architectural drawings. Verify all field conditions and confirm column locations in respect to building wall alignment prior to the start of work. All dimensions and conditions must be verified in the field. Any discrepancies shall be brought to the attention of the engineer before proceeding with the affected part of the work. It is the contractor's responsibility to determine erection procedures and sequence to ensure safety of the building and its components during erection. This includes the addition of necessary shoring, sheeting, temporary bracing, guys or tiedowns. The Contractor shall perform no portion of the work at any time without Contract Documents or, where required, approved shop drawings, product data or supplemental details for such portion of the work. The plans show the location of all fixtures & equipment & are intended to convey the general intent of the work in scope & layout. They are not intended to show in minute detail all of the accessories intended for the purpose of execution of the work, but it is understood that such details are part of this work. EXISTING STRUCTURE: Information shown for the existing structure was taken by field inspection and observation by contractor. Work shown on these plans assumes that the original construction was performed in accordance with the standard building code and accepted industry practices at time of construction. It shall be the responsibility of the contractor to verify the conditions relating to the existing structure and to notify the engineer immediately of any discrepancies or conflicts. DESIGN LOADS: The structural system for this building has been designed in accordance with the Florida Building Code, 7th edition (FBC 2020). The following loads have been utilized: Roof: Live Load - 20 Psf. Dead Load - 25 Psf. Handrails and Guards (Loads below need not be applied concurrently): Live Load (Uniform) - 50 Plf. Live Load (Concentrated) - 200 Lbs. (Any Direction/Any Location) Roof Live reductions shall be based on area as outlined in the Florida Building Code. Roof drainage shall conform to the requirements of the Florida Plumbing Code Section 11. Wind load based on using the ASCE 7-16 "Minimum Design Loads and Associated Criteria for Buildings and Other Structures" methods of calculation for wind pressures and the following factors: Ultimate Wind Speed - 137 Mph Allowable Wind Speed - 107 Mph Exposure C Enclosed Structure Risk Factor II This building is NOT IN A WIND BORNE DEBRIS REGION as defined by Florida Building Code. SHOP DRAWING REVIEW: Shop drawings will be reviewed for general compliance with the design intent of the contract documents only. It shall be the responsibility of the contractor to verify compliance with the contract documents as to quantity, length, elevations, dimensions, etc. All shop drawings shall be reviewed by the contractor prior to submittal to the architect/engineer. Drawings submitted without review notation will be returned unchecked. Shop drawings or submittals are required to be (1) electronic copy (combined PDF format) and shall be submitted along with a transmittal. Contractor shall allow for (10) ten business days for shop drawing and submittal review. One set of prints will be retained by the engineer and one by the architect, the contractor shall receive the remaining prints for submittal to the building department and as required for distribution. In all instances the contract documents will govern over the shop drawings unless otherwise specified in a request for information (RFI) or similar documentation by the engineer. Shop drawings should be submitted for all components of the structural framing system, as required by the architect, and as noted elsewhere in these notes, including, but not limited to: Any Alternate Material/Product Substitutions CHEMICAL ANCHORS: Shall be an equal two-part epoxy polymer injection system, such as Simpson Set-XP "Structural Anchoring Adhesive", HILTI HIT-HY 200 MAX or engineer approved substitution, installed in accordance with manufacturer's instructions. Installers shall be trained by the manufacturer's representative. Brush and blow out all holes. The threaded rods to be used in combination with Epoxy system shall be fabricated from steel meeting or exceeding the properties of ASTM A36. MACHINE AND LAG BOLTS: Shall be A307 hot dipped galvanized with galvanized washers. WOOD: Structural wood components (beams, joists, rafters, etc.) Shall have the following minimum allowable fiber stresses for No.2 Southern Pine conforming to NDS, with 2018 supplement, as follows: Shear Fv = 175 Psi. Bending 2x4 Fb = 1,100 Psi. Bending 2x6 Fb = 1,000 Psi. Bending 2x8 Fb = 925 Psi. Bending 2x10 Fb = 800 Psi. Bending 2x12 Fb = 750 Psi. Wood in contact with concrete or masonry, and at other locations as shown on structural drawings, shall be protected or pressure treated in accordance with AITC 109. Member sizes shown are nominal unless noted otherwise. All nails shown on plans assume common wire nails unless specifically noted on drawings. Plywood roof, floor, and wall sheathing are designed as diaphragms and shall comply with applicable provisions of Chapter 23 of The Florida Building Code and shall be fastened in accordance with structural drawings, plan notes and applicable details. Plywood shall be installed with the strength axis of each panel perpendicular to the supports in all cases. Plywood roof panels shall be installed as shown in cases 1 through 4 in FBC Table 2306.2(1). Minimum fastening requirements for built up wood framing, blocking, member connections and plywood sheathing shall not be less than that set forth in FBC Table 2304.10.1. Attachment of plywood sheathing to resist wind pressures shall also not be less than what is shown in FBC Table 2304.6.1. MANUFACTURED WOOD STRUCTURAL COMPONENTS: Members designated'LVL' (e.g.,1_3/4 x 14 LVL) shall be laminated veneer lumber as manufactured by Trus Joist Corporation (MicroLam), alpine engineered products (ASI Timbermax LVL), or engineer approved substitution. Fb = 2600 psi, E=1,900,000 psi, Fv = 285 psi. Members designated 'PSL' (e.g., 3Y"x11'/." PSL) shall be Parallam parallel strand lumber as manufactured by Trus Joist Corporation (MicroLam), or engineer approved substitution. Fb = 2900 psi, E = 2,000,000 psi, Fv = 290 psi. Members designated 'APB' (e.g., 3%:"x11%" APB) shall be Anthony Power Beam LSL as manufactured by Anthony Forest Products Comapany, or engineer approved substitution. Fb = 3000 psi, E = 2,100,000 psi, Fv = 290 psi. WOOD FRAMING CONNECTORS: All connectors shall be galvanized. Connector model numbers shown are strong -tie connectors as manufactured by Simpson Strong -Tie Co. Substitutions are acceptable with the approval of the structural engineer. Unless shown otherwise, install size and maximum number of fasteners shown in latest Simpson catalog. WIND ZONES SCHEDULE M1M_ C&C ROOF WIND PRESSURES ZONE TRIBUTARY AREA (SF) POSITIVE PRESSURE (PSF) NEGATIVE PRESSURE (PSF) x 5 20 30.5 75.6 1 20 < x 5 50 23.6 75.6 50 < x 5 100 21.8 46.1 x > 100 18.4 23.6 x 5 20 30.5 75.6 2e 20 < x 5 50 23.6 75.6 50 < x 5 100 21.8 46.1 x > 100 18.4 23.6 x 5 20 30.5 110.2 2n 20 < x 5 50 23.6 94.6 50 < x 5 100 21.8 75.6 x > 100 18.4 60.0 x 5 20 30.5 110.2 2r 20 < x 5 50 23.6 94.6 50 < x 5 100 21.8 75.6 x > 100 18.4 60.0 x 5 20 30.5 110.2 3e 20 < x 5 50 23.6 94.6 50 < x <_ 100 21.8 75.6 x > 100 18.4 60.0 x 5 10 30.5 131.1 3r 10<x520 23.6 112.0 20 < x 5 50 21.8 87.7 50 < x <_ 100 18.4 68.6 C&C WALL WIND PRESSURES ZONE TRIBUTARY AREA (SF) POSITIVE PRESSURE (PSF) NEGATIVE PRESSURE (PSF) x 5 20 40.9 44.4 20 < x 5 50 39.2 42.6 4 50 < x 5 100 37.4 40.9 x > 100 35.7 39.2 x 5 20 40.9 54.8 5 20<x550 39.2 51.3 50 < x 5 100 37.4 46.1 x > 100 35.7 42.6 NOTES: 1. DESIGN CRITERIA: WIND SPEED 137 MPH EXPOSURE CATEGORY C RISK CATEGORY II ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFF. t0.18 ROOF SLOPE 200 < x 5 270 2. ABOVE WIND LOADS ARE ULTIMATE BASED ON ASCE 7-16. WIND LOADS CAN BE CONVERTED TO ASD BY MULTIPLYING BY 0.6. 3. POSITIVE PRESSURES INDICATE PRESSURES ACTING TOWARDS A PROJECTED SURFACE. 4. NEGATIVE PRESSURES INDICATE PRESSURES ACTING AWAY FROM A PROJECTED SURFACE. 5. BUILDING IS NOT IN A WIND-BORNE DEBRIS REGION. FASTENING SCHEDULE PER FBC TABLE 2304.10.1 CONNECTION FASTENING LOCATION TOP PLATE TO STUD 2- 16d COMMON END NAIL STUD TO SOLE PLATE 4- 8d COMMON 2- 16d COMMON TOE NAIL END NAIL DOUBLE STUDS 16d AT 24" OC FACE NAIL DOUBLE TOP PLATES DOUBLE TOP PLATES 16d AT 16" OC 8- 16d COMMON TYPICAL FACE NAIL LAP SPLICE BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE 3- 8d COMMON TOE NAIL TOP PLATES, LAPS AND INTERSECTIONS 2- 16d COMMON FACE NAIL CONTINUOUS HEADER, TWO PIECES 16d COMMON 16" OC ALONG EACH EDGE STAGG CEILING JOISTS TO PLATE 3- 8d COMMON TOE NAIL CONTINUOUS HEADER TO STUD 4- 8d COMMON TOE NAIL BUILT-UP CORNER STUDS 16d COMMON 24" OC d Z Q Z LU W � O MU)0 I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES Drawn by: NM Checked by: NM Issue Date: 03-15-2021 Project Number: 21-004 Revisions: a� 0 a. J W O" 3 W Lcc",)) WLL �CO W O c'M I W w W N Z u7 1 cMM QU J LL �WW >.Da J = �UU Z C' w C)LO J Wow o. 866 13 c? ,,ass' C•S:!�Jz�rL1 �� NICOLAS MENDIETA FL P.E. # 86662 STRUCTURAL NOTES & WIND PRESSURES S001 EXISTING WOOD TRUSSES/JOISTS TO REMAIN. REPLACE EXISTING CONNECTIONS IN KIND TO NEW WOOD BEAM EXISTINC TRUSSES/JOI F 1 SECTION S 101 REF: S101 SCALE: 3/4" = 1'-0" 2 SECTION S 101 REF: S101 SCALE: 3/4" = 1'-0" WOOD BEAM, SEE PLAN CONNECTOR, SEE PLAN WOOD COL., SEE PLAN XISTING WOOD RUSSESMOISTS TO EMAIN. REPLACE XISTING CONNECTIONS IN IND TO NEW WOOD BEAM 100D BEAM, SEE PLAN ONNECTOR, SEE PLAN . JOOD BEAM, SEE PLAN O C. At. ROOF FRAMING PLAN SCALE: 3/8" = 1'-0" WOOD COLUMN SCHEDULE MARK SIZE GRADE BASE CAP REMARK 8 PT4x4 S.Y.P. ABA44Z CCQ4.62-3.62SDS - NOTES: AT ABU44Z, USE 5/8" DIA. EPDXY ANCHORS W/ 6" MIN. EMBED. ROOF FRAMING PLAN NOTES: 1. GC VERIFY ALL DIMENSIONS AND ELEVATIONS IN FIELD. SEE BUILDING SHEETS FOR ADDITIONAL INFORMATION. 2. ELEVATIONS SHOWN ARE RELATIVE TO THE FIRST FLOOR SURFACE SET AT 0'-0" (REF.) 3. =Z13 INDICATES 2x4 WOOD STUD INFILL BELOW. PROVIDE R" APA RATED EXTERIOR WALL SHEATHING WITH 8D NAILS AT 6" O.C. AT ALL SUPPORTED PANEL EDGES & 12" O.C. IN FIELD. 4. INDICATES AN EXISTING 2x4 LOAD BEARING WOOD STUD WALL BELOW TO BE REPLACED IN KIND WITH DOUBLE TOP PLATE AND STUDS AT 16" O.C. MAX. PROVIDE �' GYP. SHEATHING EACH SIDE. COLUMN SYMBOLS 5. ALL WOOD JOISTS, WOOD TRUSSES AND ROOF SHEATHING TO REMAIN. 6. AT EXISTING WOOD ROOF TRUSSES, PROVIDE PERMANENT & CONTINUOUS BOTTOM CHORD INDICATES COLUMN BELOW BLOCKING AT 36" O.C. MAX. WITH (2) 10d TOE NAILS AT EACH END. 7. SEE SHEET S001 FOR WOOD FASTENING SCHEDULE. O INDICATES COLUMN THRU 0 INDICATES COLUMN ABOVE U Z J � Q � z W 0 U) Z W Z M U) O r14, I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES Drawn by: NM Checked by: NM Issue Date: 03-15-2021 Project Number: 21-004 Revisions: A ff a c m U J W 0 ON W M W`ALL C/) J 00= W W N Z IT ul 1 M QUA LL 2W W �oa J = Zit } oW J WSW NIC'IUWANOMIETA FL P.E. # 86662 ROOF FRAMING PLAN & SECTIONS ELECTRICAL NOTES GENERAL NOTES: EQUIPMENT FURNISHED AND PHYSICALLY INSTALLED BY "OTHERS". ALL ELECTRICAL CONNECTIONS EXTERNAL TO THE EQUIPMENT SHALL BE MADE BY THE ELECTRICAL CONTRACTOR. WIRE, CONDUIT, LUGS, RECEPTACLES, PIGTAILS, DISCONNECTS, ETC. AS MAY BE REQUIRED SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR. INCLUDE WORSE CONDITION IN PRICING. VERIFY ROUGH -IN LOCATIONS, TYPE OF CONNECTION AND AMPACITY REQUIRED FROM APPLICABLE EQUIPMENT DRAWINGS PRIOR TO INSTALLING ANY CONDUIT, CONDUCTORS OR BOXES. 2. WALL TELEPHONE/DATA OUTLET. INSTALL 2-GANG BOX WITH MODULAR TELEPHONE DEVICE IN COVER PLATE. INSTALL (2) 3/4" EMT CONDUITS TO ACCESSIBLE CEILING SPACE OR HOMERUN TO TELEPHONE/COMPUTER TERMINAL EQUIPMENT. HEIGHT, UNLESS NOTED, IS 18" ABOVE FINISH FLOOR. 3. RESIDENTIAL TYPE, 120 VOLT AC/DC, SINGLE STATION SMOKE DETECTOR, PHOTOCELL TYPE LOCATE PER N.F.P.A. #74. 4. PROVIDE LIGHT FIXTURE AND RECEPTACLE AT LOCATIONS INDICATED FOR HVAC MAINTENANCE LIGHTING. USE COMBINATION SWITCH AND RECEPTACLE FOR LIGHT CONTROL. FIELD DETERMINES EXACT LOCATION AND HEIGHT. 5. SWITCHED JUNCTION BOX IN CEILING FOR CEILING FAN OR LIGHT. NOTE: BOX MUST BE IDENTIFIED FOR FAN SUPPORT USE). ANCHOR TO STRUCTURE TO SUPPORT 75 LBS. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL FAN AND/OR LIGHT, AND ALL WIRING, INCLUDING SWITCH AND POWER LEGS. VERIFY AND COORDINATE FAN TYPE WITH OWNER. 6. THE ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH ALL STATE/LOCAL BUILDING CODES/ORDINANCES/REGULATIONS PRESENTLY IN EFFECT. IN ADDITION, COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE (N.E.C.) PRESENTLY IN EFFECT. 7. THE DRAWINGS ARE DIAGRAMMATIC, AND DO NOT SHOW ALL CHANGES IN HEIGHT, STRUCTURAL MEMBERS, DUCTWORK, PIPING, BRACKETS AND ANY OTHER NUMBER OF ITEMS WHICH MIGHT CAUSE A CONFLICT. THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH OTHER TRADES AS TO THE LOCATION OF HIS DEVICES AND NECESSARY AREAS FOR PANELS AND CONDUIT/WIRING RUNS. VERIFY AND COORDINATE ALL ELECTRICAL WORK WITH ALL TRADES TO PROVIDE A TIMELY INSTALLATION. ADDITIONAL CHARGES DUE TO LACK OF COORDINATION WILL NOT BE APPROVED. 8. SWITCHED JUNCTION BOX IN CEILING FOR CEILING FAN OR LIGHT. NOTE: BOX MUST BE IDENTIFIED FOR FAN SUPPORT USE). ANCHOR TO STRUCTURE TO SUPPORT 75 LBS. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL FAN AND/OR LIGHT, AND ALL WIRING, INCLUDING SWITCH AND POWER LEGS. VERIFY AND COORDINATE FAN TYPE WITH OWNER. 9. ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMANLIKE MANNER BY PERSONS SKILLED IN THE TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED TO DO WORK IN THE AREA WHERE THE PROJECT IS TO BE CONSTRUCTED. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE LATEST COPY OF THE NATIONAL ELECTRIC CODE PRESENTLY ENFORCED AND AS ATTENDED TO BY THE LOCAL MUNICIPALITY. 10. ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH ANSI, NFPA70, STATE OF FLORIDA LAWS, AND ALL LOCAL RULES AND REGULATIONS, INCLUDING THE NATIONAL ELECTRIC CODE AND THE FLORIDA ENERGY CODE PRESENTLY IN EFFECT. 11. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND PAYING ALL FEES ASSOCIATED THEREWITH. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING INSPECTIONS, INCLUDING ALL FEES ASSOCIATED WITH REINSPECTIONS. 12. ALL MATERIALS SHALL BE NEW, FREE FROM DEFECTS, AND SHALL BE LISTED BY AND BEAR THE U.L. LABEL WHERE SUBJECT TO APPROVAL. MATERIALS SHALL BE OF THE SAME MANUFACTURER OR BRAND FOR EACH TYPE OF MATERIAL, UNLESS DESIGNATED OTHERWISE. 13. SWITCHES SHALL BE 20 AMP, SPECIFICATION GRADE TOGGLE SWITCHES, SIDE WIRED WITH GROUNDING TERMINAL; COLOR SHALL BE WHITE (UNLESS NOTED OTHERWISE) WITH MATCHING COVERPLATE; MOUNTING HEIGHT SHALL BE +48" AFF TO BOTTOM. 14. THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE IN ORDER TO FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS, FAILURE TO DO SO WILL NOT WARRANT ANY ADDITIONAL CHARGES TO THE OWNER. 15. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID, ANY CUTTING OR PATCHING OF CONCRETE/ASPHALT PAVEMENTS, ETC. TO RUN ELECTRICAL. 16. ROUGH -IN LOCATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS, AS WELL AS EQUIPMENT SIZE, TO AVOID CONFLICT WITH OTHER TRADES. 17. PRIOR TO ROUGH -IN, THE ELECTRICAL CONTRACTOR SHALL RELOCATE, AS DIRECTED BY THE OWNER/ARCHITECT, ANY PIECE OF EQUIPMENT IN THE VERTICAL AND/OR HORIZONTAL DIRECTION UP TO 15'-0" FROM THE LOCATION SHOWN ON THE DRAWINGS AT NO ADDITIONAL COSTS TO THE OWNER. 18. ALL FIXTURES SHALL BE AS LISTED IN THE LIGHTING FIXTURE SCHEDULES/ RECOMMENDATIONS. 19. LIGHTING FIXTURES ARE TO BE FURNISHED, INSTALLED, AND LAMPED UNDER THIS CONTRACT. 20. EXTERIOR DISCONNECT SWITCHES SHALL BE NEMA 3R ENCLOSURES AND ELECTRICALLY PROTECTED AS PER MANUFACTURER'S SPECIFICATIONS. (SEE MECHANICAL). 21. INTERIOR DISCONNECT SWITCHES SHALL BE NEMA 1 ENCLOSURES AND ELECTRICALLY PROTECTED AS PER MANUFACTURER'S SPECIFICATIONS. (SEE MECHANICAL) 22. SWITCHES SHALL BE 20 AMP, SPECIFICATION GRADE TOGGLE SWITCHES, SIDE WIRED WITH GROUNDING TERMINAL; COLOR SHALL BE WHITE (UNLESS NOTED OTHERWISE) WITH MATCHING COVERPLATE; MOUNTING HEIGHT SHALL BE +48" AFF TO BOTTOM. 23. RECEPTACLES SHALL BE 20 AMP (MINIMUM), SPECIFICATION GRADE, SIDE WIRED WITH GROUNDING TERMINAL; COLOR SHALL BE WHITE (UNLESS NOTED OTHERWISE) WITH MATCHING COVERPLATE; MOUNTING HEIGHT NOTED IN SYMBOL LEGEND OR ON DRAWING. 24. ALL RECEPTACLES INSTALLED IN KITCHENS, OR WITHIN 6 FEET (6) OF A WATER SUPPLY (i.e.: SINK), SHALL BE GROUND FAULT CIRCUIT INTERRUPTER (G.F.C.I.) DEVICES WITH DOWNSTREAM DEVICES IDENTIFIED. 25. ALL 120-VOLT, SINGLE PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN BATHROOMS SHALL HAVE GROUND -FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL. 26. ALL CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE SPECIFIED ON PLANS. 27. MINIMUM BRANCH CIRCUIT WIRING SHALL BE #12 AWG THWN COPPER. EXCEPTION NO. 1: BRANCH CIRCUIT WIRING FOR DEDICATED LOADS, SUCH AS A PERMANENTLY INSTALLED APPLIANCE OR OTHER EQUIPMENT, SHALL BE SIZED ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS FOR THAT APPLIANCE OR EQUIPMENT, OR BY THE N.E.C. PRESENTLY IN EFFECT, WHICHEVER IS GREATER. REFER TO PANEL SCHEDULES. EXCEPTION NO. 2: MINIMUM BRANCH CIRCUIT WIRING WITHIN DWELLING UNITS SHALL BE #14 THWN COPPER. WIRING METHODS: BELOW GRADE: SINGLE- OR MULTI -CONDUCTOR COPPER WIRE WITH GROUND, MEETING N.E.C. AND NEMA REQUIREMENTS, IN APPROVED NONMETALLIC CONDUIT. CONDUIT MAY BE RUN IN OR BELOW CONCRETE, AND CONCEALED IN WALLS TO FIRST BOXES. ALL PVC COMPONENTS (PIPING, FITTINGS, CEMENT, ETC.) SHALL BE FROM THE SAME MANUFACTURER. EXTERIOR ABOVE GRADE: SINGLE - OR MULTI -CONDUCTOR COPPER WIRE WITH GROUND, MEETING N.E.C. AND NEMA REQUIREMENTS, IN APPROVED METALLIC OR NONMETALLIC CONDUIT. ALL COMPONENTS (PIPING, FITTINGS, ETC.) SHALL BE FROM THE SAME MANUFACTURER. THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH -IN AND INSTALLATION DETAILS, FEES, WITH THE LOCAL POWER COMPANY/UTILITY FIELD ENGINEER PRIOR TO AND INCLUDE IN BID! THE ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH ALL STATE/LOCAL BUILDING CODES/ORDINANCES/REGULATIONS PRESENTLY IN EFFECT. IN ADDITION, COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE (N.E.C.) PRESENTLY IN EFFECT. THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE IN ORDER TO FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS, FAILURE TO DO SO WILL NOT WARRANT ANY ADDITIONAL CHARGES TO THE OWNER. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID, ANY CUTTING OR PATCHING OF CONCRETE/ASPHALT PAVEMENTS, ETC. TO RUN ELECTRICAL. ALL EQUIPMENT, FIXTURES, ETC. SHALL BE STARTED, TESTED, ADJUSTED AND PLACED IN SATISFACTORY OPERATING CONDITION. THIS CONTRACTOR SHALL GUARANTEE ALL WORKMANSHIP, MATERIALS AND EQUIPMENT TO BE FREE OF DEFECTS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF CERTIFICATE OF OCCUPANCY (C.O.), AND SHALL REPAIR ANY SUCH DEFECTS WITHOUT COST TO THE OWNER. ALL EQUIPMENT SHALL BE COVERED FOR THE DURATION OF THE MANUFACTURER'S GUARANTEE OR WARRANTY. THIS CONTRACTOR SHALL FURNISH THE OWNER WITH ALL MANUFACTURER'S GUARANTEE AND WARRANTIES. "WAFER" OR "PIGGYBACK" BREAKERS SHALL NOT BE PERMITTED. THE ELECTRICAL CONTRACTOR IS TO INSTALL MODULAR METERING SERVICE EQUIPMENT EITHER PROVIDED BY THE GOVERNING UTILITY COMPANY OR OF A TYPE APPROVED BY THE UTILITY COMPANY AND U.L. LISTED. IMMEDIATELY AFTER SUB -CONTRACT AWARD, CONTACT WITH THE UTILITY COMPANY SHALL BE MADE FOR COORDINATION OF SERVICE AND METERING DETAILS. HVAC AIR HANDLER AND CONDENSING UNIT CIRCUIT BREAKERS MUST BE U.L. LISTED AS "HACK" RATED IN ORDER TO USE NON -AUTO DISCONNECTS AT HVAC EQUIPMENT. IF NOT LISTED, THEN A FUSED DISCONNECT IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S NAMEPLATE REQUIREMENTS MUST BE INSTALLED AT THE EQUIPMENT. THE ELECTRICAL, GENERAL, HVAC, AND PLUMBING CONTRACTOR(S) SHALL STRICTLY ADHERE TO THE FOLLOWING ITEMS WHEN DEALING WITH ELECTRICAL EQUIPMENT CLEARANCES: A.) NO PIPING OR DUCTWORK OF ANY KIND SHALL BE INSTALLED ABOVE ANY SWITCHBOARD OR PANELBOARD. THIS AREA TO REMAIN CLEAN FROM THE EQUIPMENT TO 25' ABOVE OR TO THE BOTTOM OF THE STRUCTURAL SLAB. B.) A CLEARANCE OF 36" MINIMUM SHALL BE MAINTAINED IN FRONT OF ELECTRICAL EQUIPMENT FOR THE ENTIRE WIDTH OF THE EQUIPMENT, PLUS A MINIMUM OF 30" TOTAL LEFT/RIGHT CLEARANCE. ALL "WEATHERPROOF" ("WP") DEVICES ARE TO BE INSTALLED WITH A WEATHER -SHIELDING COVER. ALL ELECTRICAL CONDUITS NOT CONTAINING SPECIFIED CONDUCTORS SHALL HAVE A PULL WIRE INSTALLED. DO NOT SCALE THE ELECTRICAL DRAWINGS; REFER TO THE ARCHITECTURAL PLANS FOR EQUIPMENT LOCATIONS, CABINETRY, CEILING GRIDS, DOOR SWINGS, ETC. THE INTENT OF THESE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL INSTALLATION. IT IS NOT THE INTENT OF THESE PLANS TO SHOW ALL DETAILS OF CONSTRUCTION. THE ELECTRICAL CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS SUCH AS HARDWARE, J-BOXES, CONDUIT FITTINGS, ETC., AS NECESSARY FOR A COMPLETE ELECTRICAL SYSTEM INSTALLATION. TECHNICIANS SKILLED IN THEIR TRADE SHALL PERFORM ALL ELECTRICAL INSTALLATIONS IN A PROFESSIONAL MANNER. WIRE TO, AND MAKE CONNECTIONS AS NECESSARY, TO ALL PIECES OF EQUIPMENT (FURNISHED BY OTHERS), FOR COMPLETE AND SATISFACTORY OPERATION BY THE OWNER. PROVIDE CIRCUIT BREAKERS, AS NECESSARY, TO ACCOMMODATE ALL NEW CIRCUITS INSTALLED. ALL SERVICE AND FEEDER CONDUITS SHALL HAVE EXPANSION FITTINGS WHEN PENETRATING SLABS, ETC. TO ALLOW FOR STRUCTURAL SETTLEMENT. PROVIDE "PVC" CONDUITS STUBBED OUT, BELOW GRADE FOR ADDITIONAL SERVICES, IN ORDER TO PROVIDE CONCEALED TELEPHONE AND/OR DATA SERVICE ENTRANCE. PROVIDE TIME CLOCKS WITH BATTERY BACK-UP TO CONTROL ALL SIGNAGE AND EXTERIOR LIGHTING CIRCUITS; SEE POWER RISER DIAGRAM FOR ADDITIONAL DETAILS. ALL CONDUCTORS SHALL BE TYPE THHN/THWN, COPPER (CU) UNLESS OTHERWISE CALLED FOR ON THESE DOCUMENTS. SEE PANEL SCHEDULE. ALL LIGHTING FIXTURES (INCLUDING THOSE PROVIDED BY OTHERS) ARE TO BE INSTALLED UNDER THIS CONTRACT. SEE SCHEDULE FOR FIXTURE RECOMMENDATIONS, LAMPS, ETC. NOTICE TO CONTRACTOR: REVISIONS TO THESE DRAWINGS AND CERTIFICATION THEREOF WHICH MAY BE REQUIRED BECAUSE OF CONTRACTOR OPTED REVISIONS, SHALL BE COMPENSATED TO THE ENGINEER(S) BY THE REQUESTING CONTRACTOR. PAYMENT SHALL BE REQUIRED AT THE TIME OF CERTIFICATION DELIVERY. BATHROOMS WITH 3 SF. WINDOW OPENING ARE NOT REQUIRED TO HAVE A FAN. CONTRACTOR'S NOTES LIMITED ENGINEERING FIELD INVESTIGATIONS HAVE BEEN CONDUCTED (AS AND AID TO THE CONTRACTOR), TO ILLUSTRATE EXISTING CONDITIONS. THIS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO CONDUCT HIS OWN PERSONAL FIELD INVESTIGATION, WHICH MAY UNCOVER ADDITIONAL CONDITIONS, THUS IMPACTING THIS INSTALLATION. EQUIPMENT ELECTRICAL ROUGH INs HAVE BEEN COORDINATED AND ARE LISTED IN PANEL SCHEDULES. THE CONTRACTOR IS CAUTIONED TO VERIFY THE ELECTRICAL REQUIREMENTS OF EACH PIECE OF EQUIPMENT PRIOR TO ROUGH -IN, WHICH MAY RESULT IN REVISING CERTAIN EQUIPMENT CIRCUITS. THE A/E SHALL BE ADVISED OF ANY AND ALL REVISIONS REQUIRED TO THESE CONSTRUCTION DOCUMENTS. CONTRACTOR TO VERIFY VOLTAGE WITH UTILITY COMPANY PRIOR TO BID, OR ANY CONSTRUCTION. ELECTRICAL PLAN SCALE: 3/8" = 1'-0" SYMBOL LEGEND SYMBOL DESCRIPTION REMARK SWITCH: SINGLE POLE 50" AFF t SWITCH: THREE WAY 50" AFF 6 DUPLEX RECEPTACLE 20" AFF DUPLEX RECEPTACLE 44" AFF DUPLEX RECEPTACLE 50" AFF 6 DUPLEX RECEPTACLE 69" AFF 220 RECEPTACLE 50" AFF GFCI GROUND FAULT CIRCUIT INTERRUPTER CEILING LIGHT a WALL MOUNTED LIGHT FIXTURE I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES Drawn by: NM Checked by: Issue Date: 03-15-2021 Project Number: 21-004 Revisions: A W 0 ON W M WALL �U)J J O�2 LU W N F_ Z u7 It QUA LL UJ W >a J J �U U Z� } O W W J ow c m U JAVIER GOMEZ EC13009619 & CAC1817440 W:k4&r E101