HomeMy WebLinkAbout38023 Medical Center AveGENERAL NOTES 1. ALL WORK SHALL CONFORM WITH THE LATEST ADOPTED EDITION OF THE "FLORIDA BUILDING CODE," THE "NATIONAL ELECTRIC CODE" AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL CODES AND ORDINANCES, AND ALL AUTHORITIES HAVING LOCAL JURISDICTION. 2. ANY EXISTING CONDITIONS WHICH DIFFER SUBSTANTIALLY FROM THAT INDICATED ON THE ATTACHED PLANS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT, BEFORE PROCEEDING WITH OR CONTINUING ANY FURTHER CONSTRUCTION. 3. IN THE EVENT OF ANY DIFFERENCES OR CONFLICTS BETWEEN THESE CONTRACT DOCUMENTS AND THE AGREEMENT BETWEEN THE CONTRACTOR AND THE OWNER. THE TERMS AND CONDITIONS OF THAT AGREEMENT SHALL GOVERN AND PREVAIL. NO EXCLUSIONS FURTHER THESE DOCUMENTS ARE SUBJECT TO REVIEW, CHANGES AND FINAL APPROVAL. 4. THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED FROM THE MOST COMPLETE FIELD INFORMATION AVAILABLE TO THE ARCHITECT. ALL THE DATA ON EXISTING CONSTRUCTION CONDITIONS IS APPROXIMATE AND SHALL BE VERIFIED PRIOR TO COMMENCING ANY WORK. ANY CONDITIONS WHICH DIFFER SUBSTANTIALLY FROM THAT INDICATED ON THESE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT, BEFORE PROCEEDING WITH OR CONTINUING ANY FURTHER CONSTRUCTION AS THE SITUATION WARRENTS. 5. CONTRACTOR SHALL COMPLY FULLY WITH THE RULES AND REGULATIONS FOR CONSTRUCTION AS ESTABLISHED BY LOCAL JURISDICTION AND ITS AUTHORIZED AGENTS. 6. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE "GENERAL CONDITION OF THE CONTRACT" A.I.A. DOCUMENT A201 AND SHALL COMPLY WITH THE REQUIREMENTS OF THE CONSTRUCTION CONTRACT. 7. ALL WORK (EQUIPMENT, MATERIALS, AND LABOR) SHALL HAVE WRITTEN GUARANTEE FOR A PERIOD OF ONE (1) YEAR, UNLESS SPECIFIED OTHERWISE, FROM THE DATE OF SUBSTANTIAL COMPLETION, AGAINST ANY DEFECTS IN SAID WORK, WITH APPROPRIATE REPAIR OR REPLACEMENT AT NO ADDITIONAL COST TO THE OWNER. 8. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY DISCREPANCIES OR OMISSIONS WHICH WOULD INTERFERE WITH SATISFACTORY COMPLETION OF WORK. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL FIELD MEASUREMENT. FIELD CONSTRUCTION AND INSTALLATION CRITERIA. COORDINATION OF ALL TRADES AND TENANT SUPPLIED ITEMS. AND THE MEANS AND METHODS OF CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ARRANGING FOR ELEVATORS, HOISTING FACILITIES, PARKING, ETC., FOR THE COMPLETION OF WORK. CONTRACTOR IS RESPONSIBLE FOR HANDLING OF MATERIALS. 9. CONTRACTOR TO OVERSEE CLEANING AND ENSURE THAT THE PREMISES ARE MAINTAINED FREE OF RUBBISH DURING CONSTRUCTION. FINAL CLEANUP IS THE RESPONSIBILITY OF THE CONTRACTOR. REPAIR, PATCH, TOUCH-UP AND MAINTAIN CLEANING UNTIL OCCUPIED BY OWNER 10. AT THE TERMINATION OF THE WORK, SUBMIT TO OWNER MAINTENANCE MANUALS PRESENTING FULL DETAILS FOR CARE AND MAINTENANCE OF ALL SURFACES AND EQUIPMENT OF EVERY NATURE. CONTENTS SHALL INCLUDE MANUFACTURER'S AND INSTALLERS NAMES, ADDRESS AND PHONE NUMBER AND INSTRUCTIONS FOR INSTALLATION, START-UP OPERATION. MAINTENANCE PARTS LIST AND DATA SHEETS. 11. WHEN "APPROVED EQUALS", "EQUAL TO" OR OTHER QUALIFYING TERMS AND ARE USED, IT SHALL BE BASED UPON THE REVIEW AND APPROVAL BY ARCHITECT. 12. ALL WORK IS TO CONFORM WITH DRAWINGS AND SPECIFICATIONS. DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION. SITE LOCATION INTERIOR RENOVATIONS FOR: L 38010 MEDICAL CENTER AVENUE, OWNER: US ONCOLOGY 16825 NORTHCHASE DR., SUITE 1300 HOUSTON, TEXAS 77060 CONTRACTOR: PRECISE CONSTRUCTION INC. 5026 TRENTON STREET, SUITE 1 TAMPA, FLORIDA 33619 (813) 241-2403 ARCHITECT: GRAHAM DESIGN ASSOCIATES P.A. 585 MAIN STREET SUITE 201 DUNEDIN, FLORIDA 34698 (727) 733-9400 ELECTRICAL ENGINEER: CHEHAYEB & ASSOCIATES, INC. 3702 AZEELE STREET TAMPA, FLORIDA 33609 (813) 876-1415 BUILDING PLAN KEY PLAN SCALE: N.T.S. +p T E US Oncology ZEPHYRHILLS, FLORIDA 33540 CODES & STANDARDS COMPLIANCE THE BUILDING HAS BEEN DESIGNED TO COMPLY WITH THE FOLLOWING CODES: 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS & 2006 SUPPLIMENTS 2004 FLORIDA MECHANICAL CODE 2004 FLORIDA PLUMBING CODE NATIONAL ELECTRIC CODE 2005 (NFPA 70) FLORIDA FIRE PREVENTION CODE 2004. FLORIDA BUILDING CODE 2004, CHAPTER 11, FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION NO CHANGE TO MECHANICAL OR PLUMBING. EXISTING BUILDING DATA OCCUPANCY: BUSINESS - GROUP B CONSTRUCTION TYPE: TYPE V (SPRINKLEDIUNPROTECTED) BUILDING AREA: 5,249 S.F. BUILDING HEIGHT: 1-STORY Pits m be advised this review of plans submitted is 8 cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with 80 NFPA Codes and Will ordirwm- �l 1 4 i- �4�'Z�- Ji-..� SUBMFITED PLAN(S) HAVE BEEN REVIEWED BY ZEPHYR fS SHAV OFFIC Date: / Reviewer: rcINDEX OF DRAWINGS SHEET REVISION No. & DATE NUMBER SHEET NAME CS COVER SHEET - A101 EXISTING FLOOR PLANIDEMOLITION A102 SAW CUT FLOOR PLAN A103 NEW FLOOR PLAN A601 EXISTING and NEW REFLECTED CEILING FLOOR PLAN A602 NEW CONCRETE CEILING PLAN/DETAILS A801 SCHEDULESIDIAGRAM & NOTES E100 SPECIFICATIONS, KEY PLAN AND NOTES E200 POWER AND CONDUIT PLAN E300 RISER DIAGRAM, PANEL SCHEDULE & NOTES Lu REVISIONS No. Date - Description U z z � N Nil' � N U H wA� m� o m FI z z o 0 z UN m W E-4 H00 U o W z P4 a a O N a Z� Z c U <( Z ow 00 W �ln'a�� WcrnE4 a �Z �� G Q 1 E 0- �a� a a0r u- rn �s 0) OLuU o� - ma E� _ MOOS 0 ca Q < to Issued for: Date; ❑ PRELIMINARY ❑ PRICING ❑ BIDDING ■ PERMIT 10-01-08 ❑ CONSTRUCTION Seal OCT 0 12008 THOMAS J. GRAHAM LICENSE NO. AR 00051 12 Project No.: O 8_ 5 3 1 Drawing No: Cf 0 v m o � 0 N L�+f O Drawn by: DJB Coed by: TJG NO WORK IN SHADED AREA (TYPICAL) NO WORK IN SHADED AREA (TYPICAL) NEW FLOOR PLAN SCALE: 1/4" = V-0" BEAM PORT rL Y SHUT OFF TS EXISTING OUTLINE OF CONCRETE VAULT EXISTING PLASTIC LAMINATE CABINETS fp EXISTING PLASTIC LAMINATE OPEN SHELVES 10'-11 1 /2" EXISTING CABINETS EXISTING BLOCK STORAGE CAB. ELEV. SCALE: 1/4" = V-0" (15" DEEP CABINETS) EXISTING PL, CABINETS EXISTING PL, LAMINATE OI NO WORK IN SHADED AREA (TYPICAL) NOTE: ALL EXISTING CABINETRY & EQUIPMENT TO REMAIN UNLESS NOTED OTHERWISE. EXISTING BLOCK STORAGE CAB. ELEV. SCALE: 1/4" = V-0" (15" DEEP CABINETS) EXISTING OUTLINE OF CONCRETE VAULT EXISTING PLASTIC LAMINATE CABINETS EXISTING OPEN SHELVES 0 V3 DETAI L SCALE: 1 /2" = V-0" EXISTING GYPSUM( EXISTING NEW VER7 REMOVEF BD. AS RE RACEWAY NEW FREE COMPUTE NEW "NO" OUTLET NEW "DID" CABINET I NEW BRAI GENERAT MOUNTED NEW "XD" CABINET I 1=V1.QT1fJC,' EXISTING PLASTIC LAMINATE CABINETS NEW 1" 0 ROD VERIFY EXACT LOCATION W/ OWNER EXISTING PLASTIC LAMINATE CABINETS EXISTING FINISHED FLOOR i v rn PARTIAL ENLARGED FLOOR PLAN SCALE: 1/2" = V-0" OBLIQUE OBLIQUE EXISTING LAY -IN CEIL. SYSTEM EXISTING UPPER EXIST. CORNER SHELVES mm CABINETS TO REMAIN a NEW PLASTIC LAMINATE COUNTER TOP & BACK 7'-3" EXIST. 12"x 12" SPLASH TO MATCH EXISTING MONITOR VIEW 4 GLASS a "3 j K E SPACE \ j 0 it) EXIST. MONITOR CAB NEW PLASTIC LAMINATE @REAR SUPPORT LEG - MATCH EXIST NOTES: FIELD VERIFY AS -BUILT DIMENSIONS AND CABINETRY PRIOR TO ANY CABINET FABRICATION. 4 CONTROL�112CAB�_E�LEV... I REVISIONS I No. I Date Description Uj z N n � � 1 � 0 � � N m 00 U �; M .. � wA� 0 0 04 Z 0 z a �' U WAN W H 00 N W U 0 a �4 Issued for: Date: ❑ PRELIMINARY ❑ PRICING ❑ BIDDING ■ PERMIT 10-01-08 ❑ CONSTRUCTION 0 � 200 TH MAS J. GRAHAM LICENSE NO. AR 000,5112 z3®Z 8-53 s a 10'103 O O co O O N N O { Drawn by: DJB Checked by: TJG -� ire- i i � -T-r � 5PEG I E I GAT I ON5 I. ALL WORK SHALL BE IN STRICT AGGORDANGE WITH THE LATEST EDITION OF N.E.G. AND ALL LOCAL CODES AND ORDINANCES. L 2. ALL MATERIALS SHALL BE NEW AND OF DOMESTIC ORIGIN AND SHALL BEAR UNDERWRITERS' LABEL WHERE APPLICABLE. E 3. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN G A FIRST -GLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM 15 TO BE FULLY OPERABLE AND ACCEPTANCE OF THIS SYSTEM BY THE EN&INEER/ARCHITECT 'T' MUST BE A CONDITION OF THE SUB CONTRACT. 7 4. ALL WORK TO BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 5. CONTRACTOR TO GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM G DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE. A 6. CORRECTION OF ANY DEFECTS TO BE COMPLETED WITHOUT ADDITIONAL CHARGE L AND TO INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 1. ALL REQUIRED INSURANCE TO BE PROVIDED FOR PROTECTION AGAIN5T PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 5. CONTRACTOR TO PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTING. q. ELECTRICAL INSTALLATION TO MEET ALL STANDARD REQUIREMENTS OF LOCAL POWER AND TELEPHONE COMPANIES. 10. MINIMUM WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL WIRING. UNLE55 OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER WITH THWN/THHN INSULATION. CONDUCTORS #12 AND SMALLER MAY BE SOLID; ALL THOSE #10 AND LARGER TO BE STRANDED. II. ALL UNDERGROUND RACEWAYS SHALL BE GALVANIZED RIGID STEEL CONDUIT OR SCHEDULE 40 PVC. ALL OTHER RACEWAYS TO COMPLY WITH 6OVERNING CODES. MINIMUM CONDUIT UNDERGROUND SHALL BE 3/4" CONDUIT U.O.N. 12. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS, AND BE OF SPECIAL CONSTRUCTION FOR OTHER CLASSIFIED AREAS. ALL BOXES SHALL BE RECESSED (FLUSH) IN 14A1_1_5 OR CEILINGS WHENEVER POSSIBLE. 13. DISCONNECT SWITCHES SHALL BE H.P. RATED, GENERAL DUTY, QUICK -MAKE, QUICK -BREAK TYPE. ENCLOSURES SHALL BE AS REQUIRED BY N.E.G. AND LOCATION (WEATHERPROOF, EXPLOSION PROOF, ETC). 14. ALL GENERAL PURPOSE SWITCHES AND RECEPTACLES SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER. COLOR OF DEVICES AND PLATES SHALL BE DICTATED BY ARCHITECT/OWNER TO MATCH BUILDING STANDARD. A. SWITCHES: BUILDING STANDARD B. RECEPTACLES: BUILDING STANDARD G. COVER PLATES: BUILDING STANDARD NOTE: ALL OTHER REQUIRED DEVICES SHALL MATCH IN COLOR AND STYLE. 15. ALL RACEWAY5 AND PIPES SPACED IN OR THROUGH ANY CONCRETE SLAB SHALL BE SPACED A MINIMUM OF THREE TIMES THE DIAMETER OF THE LARGEST RACEWAY. 16. IT 15 NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CON5TRUGTJON. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FORA COMPLETE ELECTRICAL SYSTEM, AND PROVIDE ALL NECESSARY DEVICES AND COMPONENTS FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 11. ALL ELECTRICAL RACEWAYS (METALLIC, AND NON-METALLIC) SHALL HAVE AN EQUIPMENT GROUND CONDUCTOR 51ZED IN ACCORDANCE WITH THE LATEST EDITION OF THE N.E.G. 15. LOAD DATA 15 BASED ON INFORMATION GIVEN ENGINEER AT THE TIME OF DESIGN. VERIFY ALL EQUIPMENT NAMEPLATE RATINGS BEFORE ORDERING. Iq. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR 15 TO PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO SUIT JOB CONDITIONS. 20. CONDUIT SYSTEM REQUIREMENTS: ABOVE FIN15H FLOOR, CEILIN65 ETC... (INDOOR) - EMT WITH DIEGA5T SET 50REW FITTINGS. GALVANIZED RIGID CONDUITS - ABOVE GRADE AND WHERE SUSCEPTIBLE TO PHYSICAL DAMAGE. FLEXIBLE CONDUITS - INDOOR, ONLY SHORT RUNS NOT TO EXCEED 6'-O". SEAL TITE - OUTDOOR, ONLY SHORT RUNS NOT TO EXCEED 6-O". 21. ALL ELECTRICAL CONDUCTORS SHALL BE INSTALLED IN AN APPROVED RACEWAY 22• CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL CONDUIT PENETRATIONS MADE THROUGH FIRE RATED WALLS, CEILINGS, SLABS, ETC. PENETRATION SEALS SHALL BE PER U.L. A55EM13LY STANDARDS. 23. CONTRACTOR SHALL PROVIDE SHOP DRAWING SUBMITTALS FOR (IF APPLICABLE) WIRING DEVICES, AND ALL SYSTEMS. 24. TYPE 'MC' GABLE SHALL ONLY BE ALLOWED WHERE APPROVED BY OWNER'S REPRESENTATIVE AND ACCEPTED BY LOCAL AUTHORITY HAVING JURISDICTION. HOWEVER, HOMERUNS SHALL REMAIN IN CONDUITS. 'MG' GABLE USED SHALL BE TYPE 'HCF', APPROVED FOR HEALTHCARE FACILITIES FOR COMPLIANCE WITH N.E.G. 51-7-13(a) I (b) - REDUNDANT GROUNDS. L"EC END E MOUNTING HEIGHTS SHOWN ARE MAXAM/MINIMUM NOT ALL DEVICES SHOWN IN LEGEND ARE REQUIRED. HANDICAPPED ACCESSIBILITY 5TANDARM - THEY SHALL REVIEW POWER AND LIGHTING PLANS AND DETAILS L NOY BE ALTERED WITHOUT WRITTEN AUfiHORIZATION. FOR ITEMS WHICH APPLY TO TH15 PROJECT. 1--� FLUORESCENT LIGHT FIXTURE, LETTER INDICATES TYPE ® MAIN DISTRIBUTION PANEL G QB RECESSED LIGHT FIXTURE, LETTER INDICATES TYPE O SPECIAL NOTES, SEE PLANS T I o WALL BRACKET L16HT FIXTURE, LETTER INDICATES TYPE CONDUIT CONGEALED IN WALL OR ABOVE CEILIN6 WITH CO VXTOR5 0 LIGHT FIXTURE UNSWITGHED FOR NIGHT LIGHT MLJ / \ AS SHOWN ON PANEL SCHEDULE. U.OK CONDUIT CONGEAL® BELOW FLOOR SLAB OR FINISHED GRADE WITH EXIT L16W (ARROW INDICATES DIRECTION) CONDUCTORS AS SHOWN ON PANEL SCHEDULE U.ON. BATTERY POWERED EMERGENCY LIGHT CONDUIT EXPOSED ON WALL OR CEILING WITH CONDUCTORS AS SHOWN ON PANEL SCHEDULE. U.OX 5 SINGLE POLE SWITCH � FLEXIBLE CONDUIT NOT TO EXCEED 6 FEET IN LENGTH A 52 DOUBLE POLE SWITCH, MOUNT 46" A.F.F. UDN. 5s THREI=-WAY SWITCH, MOUNT 46" A.FF. U.a.N. O WIREMOLD (SIZE AND LENGTH AS NOTED) TELEVISION OUTLET, PROVIDE SINGLE 6AN6 BOX WITH 3/4" CONDUIT S° DIMMER SWITCH, WATTS AS NOTED, MOUNT 46" AF.F. U.ON Fig WITH RILL WIRE AND INSULATINS BUSHING 5TUBBED INTO CEILING SPACE. MOUNT BOX 161 A.F.F. U.ON. S" MOTOR RATED SWITCH 4=1 DISCONNECT SWITCH DUPLEX RECEPTACLE, MOUNT 18" A.F.F. U.O.N. DUPLEX REGEPTAGLE, MOUNT ABOVE COUNTER HEIGHT U.ON 100/3/80 DISCONNECT DES16HATM (SIZE/POLES/FUSE) "NF" INDICATES NON -FUSED; DE INDICATES DUAL ELEMENT FUSES. QUADRAPLEX RECEPTACLE, MOUNT 160 A.F.F. U.ON. ❑T DRY TYPE TRANSFORMER F� SPECIAL RECEPTACLE AS NOTED p CONTACTOR 06 NOTED) �eFl GROUND FAULT INTERRUPTER RECEPTACLE, LEMTON t► Mb-I, MOUNT roc TIME CLOCK ABOVE COUNTER HE16HT U.O.N. PK. PHOTOCELL 1a DUPLEX RECEPTACLE, ISOLATED 6ROUW TYPE, LEVITON e5%2-I61 MOUNT AT IS" A.FF. U.O.N. MOTOR PERMANENTLY C44244MTED WITH FLEXIBLE CONDUIT L1644TIN6 OR POWER PANELBOARD [� PUSHBUTTON, MOUNT 46" A.F.F. U.ON. TELEPHONE OR DATA WALL OUTLET, PROVIDE SINGLE 6AN6 BOX WITH 3/4" CONDUIT WITH PULL WIRE AND INSULATINS BUSHING JQ UNCTION BOX (FLUSH MOUNT IN FINISHED AREAS U.ONJ STUBBED INTO CEILING SPACE. MOUNT BOX 16" AFF. U.O.N. COMBINATION TELE/DATA OUTLET, PROVIDE DOUBLE GANG BOX WITH W TELEPHONE WALL OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4' Q SINGLE GANG MUD RING AND (2) 9/4" CONDUITS WITH PULL WIRE AND CONDUIT WITH PULL WIRE AND INSULATINS BUSHINS STUBBED INTO INSULATIN & BUSHING STUBBED INTO CEILING SPADE. MOUNT BOX GEILINS SPACE. MOUNT BOX 46" A.F.F. U.ON. ("W' INDICATES AT 16" A.F.F. U.O.N. WALL PHONE) E.6. ABBREVIATIONS EQUIPMENT GROUND EWG ELECTRIC, WATER COOLER N.L. N1644T LIGHT UDN. UNLESS OTHERWISE NOTED Le. ISOLATED GROUND E/F-EF EXHAUST FAN EX. EXISTINS DEVICE N.T.S. NOT TO SCALE WP WEATHERPROOF AM-AHU AIR HANDLING UNIT A.FF. ABOVE FINISH FLOOR N.I.G. NOT IN CONTRACT RTU ROOF TOP UNIT ACG-GU CONDENSINS UNIT NOTE: MOUNTING HEIGHTS NOTED ARE TO CENTERLINE OF DEVICE SHOWN. U.O.N. NORTH KEY PLAN SCALE: I"=10'-O" CHEHAYEB & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS CTS 3702 AZEELE ST. (813) 876-f4f5 TAMPA, FL 33609 (fax) 876-0913 LIC. #49521 SOUHEIL CHEHAYEB CERT. #7340 08-127 NOTE5 G O IT 15 THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL DRAWINGS AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, CIVIL, N STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL PRIOR TO SUBMITTING A BID. REPORT ANY D15CREPANCIE5 TO ARCHITECT OR ENGINEER T PRIOR TO BID. BIDDERS ARE TO V151T THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF /� A THE WORK. THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR r MATERIALS REQUIRED, OR FOR ANY DIFFICULTIES ENCOUNTERED WHICH COULD `i HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE T ALLOWED. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT O OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN EXISTING R 51TE CONDITIONS PRIOR TO SUBMISSION OF BID. ALL EXISTING CIRCUITS TO REMAIN SHALL BE RECONNECTED WHETHER INDICATED OR NOT ON PROJECT DOCUMENTS. NEW AND EXISTING CIRCUIT DESIGNATIONS MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. THEY ARE INTENDED FOR REFERENCE ONLY. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES IN REGARDS TO THEIR SCOPE OF WORK WHICH WILL REQUIRE ELECTRICAL WORK SUCH AS 015CONNECTION AND/OR RECONNECTION OF EQUIPMENT, AND WHICH MAY NOT BE SHOWN OR INDICATED ON THE DRAWINGS. THESE NOTES APPLY TO ALL SHEETS. No. I Date - EXISTING SERVICE WIREWAY AND DISCONNECTS - EXISTING METER AREA OF RENOVATION (THIS PROJECT) REVISIONS N3A 100F_ r.. 6 zLO n N Q w o U¢o� _D CIS V) .. � mo LiJ � T WU)z� :n E �LLJz=°'8 r Q 7 9 c) c :k Q r- o~E Q LL v: = 0 CO <V1 r/ n� , ~_ C!) bCc— _D<QHW i Issued for: Date: ❑ PRELIMINARY ❑ PRICING ❑ BIDDING ■ PERMIT is-olLos ❑ CONSTRUCTION 2 en z° � Q h ' a LLI F h tJ5 O z CT3 r L. ui U --�ILL _Q Z W o U A f] 00 M R• SOUR L c-i;AI't g, P.E. ft C. Ni 49521 t Drawn by: P.M. Checked by: S.C. J NOTE5 P 1. ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND SHALL AL50 COMPLY WITH ALL APPLICABLE RULES AND R REGULATIONS OF LOCAL AND STATE LAWS AND ORDINANCES. 0 2. ALL CONDUGTOR5 SHALL BE STRANDED COPPER, CONDUCTOR J INSULATION SHALL BE TYPE THHN THERMOPLASTIC 600 VOLT OR EQUAL U.O.N. E 3. THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED BY THE NEC. ALL METALLIC, G RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS AND EQUIPMENT. T METALLIC, RACEWAY5 SHALL BE CONNECTED TO A DIRECT GROUND AT THE POINT OF ELECTRICAL SERVICE ENTRANCE. 4. UPON COMPLETION OF WORK CORRECT ALL PANELBOARO CIRCUIT DIRECTORY CARDS TO REFLECT A5-BUILT CONDITIONS. A SET OF A5-BUILT DRAWIN655 SHALL AL50 BE PREPARED AND TURNED OVER TO THE ARCHITECT. 5. ALL RACEWAYS SHALL BE PROVIDED WITH EQUIPMENT GROUND CONDUCTOR. 6. CONTRACTOR SHALL FIELD VERIFY RECEPTACLE CONFIGURATION, VOLTAGE, PHASE AND AMPERAGE FOR ALL REQUIRED OUTLETS. PROVIDE DEDICATED CIRCUITS AS REQUIRED. ADV15E ENGINEER IF NECESSARY. -1. CONTRACTOR SHALL SUPPLY AND INSTALL ALL JUNCTION BOXES, TROU6HS, WIRE, CIRCUIT BREAKERS, WIRE, ETC., UNLESS OTHERWISE SPECIFIED. 8. CONDUIT RUNS ARE SHOWN SCHEMATICALLY. BUILDING CONDITIONS TO DETERMINE THE ACTUAL RUNS. 4. CONDUIT ELBOWS TO BE LARGE SWEEPS PER NEC, 346-10. 10. CONTRACTOR SHALL PROVIDE AND COIL A MINIMUM 10'-0 INCH OF SLACK CONDUCTOR FOR CONNECTION TO EQUIPMENT BY OTHERS. IDENTIFY BOTH ENDS OF WIRE. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE BrainLAB INSTALLATION AND 51TINO DRAWING5 PRIOR TO START OF CONSTRUCTION AND COMPLY ACCORDINGLY. 12. ALL TELEPHONE/DATA JACKS AND COMMUNICATION CABLING TO BE PROVIDED AND INSTALLED BY OTHERS. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL ASSOCIATED OUTLET BOXES AND CONDUITS. 13. CONDUITS AND DUCT, ABOVE CEILING OR BELOW FINISHED FLOOR, MUST BE INSTALLED PER BrainLAB DRAWINGS TO REDUCE RUN LENGTH. 14. THESE DRAWINGS ARE DIAGRAMMATIC AND INTENDED ONLY TO SHOW THE SCOPE OF WORK TO BE DONE. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY THE SUITABILITY OF LOCATING ALL NEW CONDUIT SHOWN ON THE PLANS OR IDENTIFIED IN THE NOTES. CONTRACTOR NOTICE I. THESE ELECTRICAL DRAWINGS HAVE BEEN DESIGNED WITH AND SHALL BE BID IN CONJUNCTION WITH THE BratnLAB INSTALLATION AND SITING DRAWING SET. SUBMISSION OF AN ELECTRICAL BID WILL BE CONSIDERED AS EVIDENCE THAT THE BrainLAB DRAWINGS WERE REVIEWED AND THAT ALL INFORMATION SHOWN HAS BEEN INCLUDED IN THE BID. LATER CLAIMS FOR ADDITIONAL COMPENSATION FOR WORK DESCRIBED ON EITHER SET OF DRAWING-5 SHALL NOT BE ACCEPTED. CONTRACTOR SHALL REVIEW G.E. DRAWINGS FOR REQUIRED USE OF ALUMINUM CONDUIT IN SPECIFIC LOCATIONS. 2. ELECTRICAL DRA"IN65 INDICATE THE INSTALLATION CONCEPT FOR THE BratnLAB EQUIPMENT. HOWEVER, CONTRACTOR SHALL OBTAIN AND BID EQUIPMENT INSTALLATION WITH BrainLAB INSTALLATION AND 51TIN6 DRAWIN65 WHICH INDICATE ADDITIONAL REQUIREMENT5 NECESSARY FOR PROPER INSTALLATION. ALL DEVICES, EQUIPMENT, APPARATUS, ETC'. USED WITHIN THE ROOM MUST BE APPROVED BY THE BrainLAB PROJECT MANAGER PRIOR TO INSTALLATION. 3. CONTRACTOR SHALL REFER TO INTERIOR ARCHITECTURAL DRAWINGS FOR EXACT MOUNTING HEIGHTS AND/OR LOCATIONS OF ALL OUTLETS AND WIRING DEVICES. NOTE5 K O CONTROL ROOM POWER BOX, FURNISHED WITH BraInLAB EQUIPMENT, INSTALLED BELOW COUNTER BY ELECTRICAL CONTRACTOR. Y X-RAY TUBE FLOOR BOX, FURNISHED WITH BrafnLAB EQUIPMENT, INSTALLED BY GENERAL CONTRACTOR. �3 PROVIDE 2+00MPARTMENt 10 x3-1/2 HORIZONTAL SURFACE WALL DUCT AT 12" A.F.F. TO TOP. VERIFY REQUIRED LENGTH, PROVIDE ALL NECESSARY FITTIN65 AND SUPPORTS. PROVIDE 6ROMMETED OPENINC75 AS DIRECTED BY EQUIPMENT SUPPLIER/INSTALLER. �4 IN -ROOM POWER BOX, FURNISHED WITH BratnLAB EQUIPMENT, INSTALLED ABOVE CEILING BY ELECTRICAL CONTRACTOR. PROVIDE ALL NECESSARY SUPPORTS. (1) 4" CONDUIT FROM XRAY TUBE FLOOR BOX, RUN BELOW SLAB, AND TURNED UP BELOW HORIZONTAL WALL DUCT. U6 VERIFY FOR REQUIRED TRANSITION FROM CONDUIT TO WALL DUCT AND PROVIDE ACCORDINGLY. O PROVIDE I" CONDUIT ("IRE) FROM EXISTING WARNING LIGHT BACK TO COMPUTER CABINET. MAKE ALL REQUIRED TERMINATIONS. ® PROVIDE A 100 AMP, 3-POLE, NON -FUSED DISCONNECT SWITCH FOR CONNECTION TO X-RAY GENERATOR. MAKE ALL REQUIRED TERMINATIONS. ® (1) 3" CONDUIT (EMPTY W/PULLWIRE) FROM GENERATOR CABINET TO CONTROL ROOM. VERIFY TERMINATIONS AT EACH END PRIOR TO ROUGH -IN AND PROVIDE ACCORDINGLY. 10 (1) 2" CONDUIT (EMPTY W/PULLWIRE) FROM COMPUTER CABINET TO CONTROL ROOM POWER BOX. II GANTRY COUGH MOUNTED INTERFACE ELECTRONIC, (BY OTHERS). 12 (1) 2" CONDUIT (EMPTY W/PULLWIRE) FROM IN -ROOM POWER BOX TO CEILING WORKSPACE. VERIFY TERMINATIONS. 13 (1) 1" CONDUIT (EMPTY W/PULLWIRE) FROM IN -ROOM POWER BOX TO FLAT PANEL DETECTORS. VERIFY TERMINATIONS. 14 (1) 1" CONDUIT (EMPTY W/PULLWIRE) FROM IN -ROOM POWER BOX TO CAMERA SYSTEM. VERIFY TERMINATIONS. 15 (1) 3 CONDUIT (EMPTY W/PULLWIRE) FROM COMPUTER CABINET TO IN -ROOM POWER BOX. I6 PROVIDE A 30 AMP, I -POLE, NON -FUSED D15CONNEGT SWITCH FOR CONNECTION TO COMPUTER CABINET. MAKE ALL REQUIRED TERMINATIONS. 17 (1) 2 CONDUIT (EMPTY W/PULLWIRE) FROM COMPUTER CABINET TO GANTRY INTERFACE. 18 (1) 2" CONDUIT (EMPTY W/PULLWIRE) FROM COMPUTER CABINET TO CAMERA SYSTEM ABOVE CEILING. Iq (1) 3" CONDUIT (EMPTY W/PULLWIRE) FROM COMPUTER CABINET TO FLAT PANEL DETECTORS ABOVE CEILING. COORDINATE WITH EQUIPMENT SUPPLIEPANSTALLER FOR CONDUIT TERMINATION REQUIREMENTS AT THE COMPUTER CABINET AND COMPLY ACCORDINGLY. 21 EXISTING EMERGENCY -OFF PUSHBUTTON FOR ACCELERATOR. CONTRACTOR SHALL USE SAME DEVICE TO ACTIVATE THE SHUNT - TRIP FOR BrainLAB MAIN BREAKER IN PANEL 'A', FOR SIMULTANE SHUT DOWN OF EQUIPMENT. 5Y5-rr=M &ROUND I NC NOTE5 THE PROPOSED BrainLAB SYSTEM REQUIRES CONNECTION TO GROUND AT A SINGLE POINT. TH15 POINT WILL BE ON THE WALL A5 A MAIN GROUND BUS BAR AND 15 THE POTENTIAL EQUALIZATION POINT. COORDINATE LOCATION OF POTENTIAL EQUALIZATION MAIN BUS BAR WITH EQUIPMENT SUPPLIER / INSTALLER. I. ALL METAL DEVICES, INCLUDING METAL SURFACES OF FIXED MEDICAL EQUIPMENT, WITHIN THE TREATMENT ROOM SHALL BE BONDED TO THE POTENTIAL EQUALIZATION GROUND BUS BAR AS INDICATED BELOW. ITEMS SHALL INCLUDE, BUT NOT LIMITED TO: a. X-RAY GENERATOR TO MAIN PEG BU5 BAR. b. BOTH FLOOR BOXES TO X-RAY GENERATOR PEG BUS BAR. c. BOTH FLAT PANEL -CEILING MOUNTS TO IN -ROOM DISTRIBUTION BOX PEG BUS BAR. d. CAMERA CEILING MOUNT TO IN -ROOM DISTRIBUTION BOX PEG BUS BAR. a. TOUGH 5GREEN CEILING FRAME TO IN -ROOM DISTRIBUTION BOX PEG BU5 BAR. F. IN -ROOM DISTRIBUTION BOX PEG BUS BAR TO MAIN PEG BU5 BAR. g. IN -ROOM DISTRIBUTION BOX PEG BUS BAR TO COMPUTER CABINET PEG BU5 BAR. h. COMPUTER CABINET PEG BUS BAR TO MAIN PEG BUS BAR. i. CONTROL ROOM DISTRIBUTION BOX TO COMPUTER CABINET PEG BUS BAR. BOTH FLOOR BOXES TO MAIN PEQ BU5 BAR. MAIN PEQ BUS BAR TO PATIENT COUGH, TABLE, LINAG FRAME. 2. VERIFY WITH EQUIPMENT SUPPLIER/I145TALLER FOR ALL REQUIRED GROUNDING LOCATIONS AND PROVIDE ACCORDINGLY. 3. DEDICATED EARTH CONDUCTOR (GROUND) SHALL BE SAME 51ZE AS POWER WIRE5 AT ALL TIMES FOR ALL ROUTINGS FROM GROUNDED NEUTRAL SOURCE TO BrainLAB EQUIPMENT. 4. CONTRACTOR SHALL REFER TO 'ELECTRICAL SAFETY / EQUIPOTENTIAL GROUNDING' SECTION 3.4 OF THE 51TE PREPARATION MANUAL FOR ALL REQUIRED TERMINATIONS AND PROVIDE ACCORDINGLY. PEQ = POTENTIAL EQUALIZATION BUS BAR. GENERAL NOTE: EQUIPMENT LAYOUT AND NOTES ARE BASED UPON GENERAL INFORMATION GIVEN TO THE ENGINEER AT TIME OF DESIGN. THE GENERAL CONTRACTOR SHALL COORDINATE ALL CONDUIT REQUIREMENTS, ALL CABLING LENGTHS AND EQUIPMENT LAYOUT OF ACTUAL EQUIPMENT FURNISHED WITH BrainLAB AUTHORIZED REPRESENTATIVE PRIOR TO CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL COORDINATE CLOSELY WITH BrainLAB REPRESENTATIVE FOR CLARIFICATION OF GABLES AND EQUIPMENT TO BE: a) SUPPLIED/INSTALLED BY BrainLAB b) SUPPLIED/INSTALLED BY CONTRACTOR c) SUPPLIED BY BrainLAB / INSTALLED BY CONTRACTOR d) AVAILABLE THROUGH BrainLAB / INSTALLED BY CONTRACTOR CRITICAL NOTE CONTRACTOR MUST COORDINATE THESE ELECTRICAL DRAWINGS WITH BrainLAB INSTALLATION DRAWING-5 FOR REFERENCE TO ADDITIONAL ELECTRICAL DETAILS AND NOTES AND PROVIDE ACCORDINGLY. CHEHAYEB & ASSOCIATES, INC. CONSULTING PROFESSIONAL ENGINEERS cTs 3702 AZEELE ST. (813) 876-1415 ` TAMPA, FL 33609 (fax) 876-0913 LIC. #49521 SOUHEIL CHEHAYEB CERT. #7340 08-127 BrainLAB COMPUTER CABINET A -I ��POWER AND CONDUIT PLAN, SCALE: 1/4" = 1'-0" CONDUIT AND WIRE SYSTEMS WITHIN TH15 ROOM SHALL COMPLY WITH REQUIREMENTS FOR REDUNDANT GROUNDING PER N.E.G. ARTICLE 4i I REVISIONS I No. I Date Description MIN u N cq W N o o' 00 U 0O C*l zN z Q N M d00 H 00 Oro O • . u in p W a a Issued for: Dater ❑ PRELIMINARY ❑ PRICING ❑ BIDDING ■ PERMIT i0-oi-oa ❑ CONSTRUCTION R EIL PHAYEB, P.E. LIC NIP. 49521 55 i -- I Drawn by: P.M. Checked by: S.C. J r .