HomeMy WebLinkAbout38444 5th Ave011 0 DRAWING INDEX ABBREVIATIONS <r _ AFF ABOVE FINISHED FLOOR HM HOLLOW METAL c CJ CONTROL JOINT HORIZ HORIZONTAL e CONIC CONCRETE MIN MINIMUM ARCHITECTURAL DBL DOUBLE MO MASONRY OPENING G001 TITLE SHEET • DIA DIAMETER MTL METAL A100 LIFE SAFETY PLAN • — DIM DIMENSION NFHB NON FREEZE HOSE BIB A101 DEMOLITION FLOOR PLAN _ • A102 NEW FLOOR PLAN • DS DOWNSPOUT NIC NOT IN CONTRACT A103 NEW CEILING PLAN _ • EWC ELECTRIC WATER COOLER NITS NOT t0 SCALE A104 FURNITURE PLAN • EXT EXTERIOR OC ON CENTER FE FIRE EXTINGUISHER PT PRESSURE TREATED A400 ENLA%ED PLANS - • FFE FINISH FLOOR ELEVATION RL. ROOF LEADER PIPE A401 DETAILS __ • FRP FIRE RATED PROTECTED A600 DOOR AND FINISH SCHEDULE - • FRT FIRE RETARDANT TREATED A601 DOOR DETAILS • FOB FACE OF BLOCK PLUMBING GALV GALVANIZED PI00 PLUMBING PLAN • GC GENERAL CONTRACTOR Pi01 PLUMBING ISOMETRIC ® GWB GYPSUM WALL BOARD GYP GYPSUM MECHANICAL HC HANDICAP Mi00 MECHANICAL PLAN • ,L�NNO ,� I ®I �l M50L 5 Mi01 SCHEDULE AND NOTES • ELECTRICAL DRAWING BLOCK TITLE EOOI SPECIFICATIONS • C4 :m e r Sheet E002 ELECTRICAL LEGEND • LTitle E101 LIGHTING PLAN • Number Scale i E201 POWER PLAN • Deta i I Area outline E301 POWER RISER AND SCHEDULE • DRAWING LABEL DETAIL LABEL No. Sheet Designation WALL SECTION LABEL GRID REFERENCE Elevation from No. 0iFiri5hed door Sheet - ELEVATION LABEL ELEVATION LEVEL INTERIOR AL TERA TION. 38444 5TH AVE. ZEPHRHILLS F.L 33542 CODE SUMMARY LOCATION:.......................................................... 3844 5TH AVE. ZEPHYRHILLS, FL 33542 SITE ZONING:...........................................................COMMERCIAL FLORIDA BUILDING CODE .................................................... 2010 FLORIDA EXISTING BUILDING CODE ........................................ 2010 FLORIDA MECHANICAL CODE ............................................... 2010 FLORIDA PLUMBING CODE..................................................2010 NATIONAL ELECTRIC CODE .................................................. 2008 FLORIDA FIRE PREVENTION CODE ........................................ 2010 PLEASE REFERENCE THE SCOPE OF WORK AND BUILDING DATA FOR ADDITIONAL INFORMATION, N LOCATION PLAN N.7.8. RROJECT TEAM SCORE OF WORK 5ULD ING DATA FROJECT GENERAL NOTES II�I OWNER: THIS IS AN ALTERATION TO THE EXISTING FIRST FLOOR TENANT SUITE LOCATED AT 3U4 5TH AVE. ZEPHRHILLS FLORIDA 33542. THE AFFECTED AREA IS APPROXIMATELY MO SQUARE FEET. THE BASED ON THE 2010 FBC I. THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY 8. PERFORM ALL WORK IN ACCORDANCE WITH ACCEPTED EXISTING SUITE IS APPROXIMATELY 5,%0 SQUARE FEET. THE PURPOSE OF THIS ALTERATION IS TO AFFECTED AREA.............................................................................. 5,950 SF ALL DIMENSIONS AND FIELD CONDITIONS AND SHALL CONFIRM CONSTRUCTION STANDARDS. ALL CONSTRUCTION SHALL BE IN FLORIDA PHARMACY SOLUTIONS, INC. MR, WES MOSS BUILD -OUT THE SPACE INTO A FUNCTIONING MIXED USE (MERCANTILE AND BUSINESS) OCCUPANCY. THAT WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR STRICT ACCORDANCE WITH THE PLANS AND SPECIFICATIONS 13933 IiTH ST. SUITE 300 TEL 855-111-19W THE SCOPE INCLUDES MODIFICATIONS TO THE EXISTING MECHANICAL AND ELECTRICAL SYSTEMS. OCCUPANCY TYPE ............. I ............................ .BUSINESS AND MERCANTILE OMISSION, ETC., SHALL BE IMMEDIATELY REPORTED TO THE UNLESS A VARIANCE IS APPROVED BY THE LANDLORD AND OR DADE CITY, FLORIDA 33525 wesmoss1vFps-rxcom THIS ALTERATION IS SUBMITTED USING THE PRESCRIPTIVE METHOD AS DEFINED IN THE FLORIDA CONSTRUCTION TYPE ..................................... EXISTING (V-B) - NO CHANGE ARCHITECT FOR CLARIFICATION PRIOR TO THE PERFORMANCE OF ARCHITECT. BUILDING CODE -EXISTING BUILDING. SPRINKLEREp........................................................................................... NO ANY WORK IN QUESTION. 9. ALL WORK PERFORMED SHALL BE IN STRICT COMPLIANCE WITH ARCHITECT THE FOLLOWING IS A BRIEF SUMMARY OF THE APPLICABLE CODE SECTIONS FROM THE 2010 FLORIDA BUILDING CODE - EXISTING BUILDING AND THE FLORIDA FIRE PREVENTION CODE: 2. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN ALL GOVERNING FEDERAL, STATE, AND LOCAL BUILDING CODE OCCUPANT LOAD - TABLE 1004JJ PARTITION LOCATIONS. ALL DOOR AND OPENING LOCATIONS REQUIREMENTS, EXECUTED IN ACCORDANCE WITH ACCEPTED WIEDRICK ARCHITECTURE, INC. MATTHEW WIEDRICK CHAPTER ONE - SCOPE AND ADMINISTRATION MERCANTILE -GRADE FLOOR AREAS (700 5QFT/30 GROSS) 24 SHALL BE ON FLOOR PLAN. IN CASE OF CONFLICT, NOTIFY THE INDUSTRY STANDARDS AND SHALL CONFORM TO SPECIFIC 2020 HEIDELBERG AVE. TEL 127-267-2300 SECTION 101B.1 COMPLIANCE METHODS: - REPAIRS, ALTERATIONS, ADDITIONS AND CHANGES OF OCCUPANCY COMPLYING WITH . BUSINESS - (3,335 SQFT/100 GROSS) ............... 34 ARCHITECT. ALL DIMENSIONS MARKED "CLEAR" SHALL BE REGULATIONS AS MANDATED BY THE OWNER, THE TENANT, AND DUNEDIN, FLORIDA 34698 matthewswiedrickarchitecturecom A CHAPTER 3 OF THIS CODE IN BUILDINGS Cf 1PLYING WITH THE FLORIDA FIRE PREVENTION ........................................................ MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES THE ARCHITECT. CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS OF THIS CODE. KITCHEN (FRONT OF HOUSE) - (192 SQFT/200 GROSS) .............................. 1 INCLUDING CARPET, PAD, TILE, VINYL, WAINSCOT, ETC. CHAPTER 3- PRESCRIPTIVE COMPLIMCE METHOD STORAGE - (1135 5QFT/300 GROSS).......................................................... 4 10. THESE DRAWINGS ARE THE PROPERTY OF WIEDRICK ARCHITECTURE MECHANICALPLUMBINGNGINR SECTION 303 ALTERATIONS: 3. CONTRACTOR SHALL COORDINATE AND OBTAIN ALL NECESSARY INC. AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR EXCEPT AS PROVIDED BY SECTION 3012 OR THIS SECTION, ALTERATIONS TO ANY BUILDING TOTAL OCCUPANT LOAD...........................................................................63 APPROVALS AND INSPECTIONS AS REQUIRED BY LOCAL PART. THESE DRAWINGS ARE TO BE USED FOR THE PROJECT AND SEEDS ENGINEERING, INC. JOHN MAKAR P.E. OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, GOVERNING JURISDICTIONS. SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED 21130 SANTA ANITA BLVD. TEL 813-902-2515 BUILDING FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NO LESS CONFORMING WITH THE PROVISIONS OF THE FLORIDA MEANS OF EGRESS ON ANY OTHER PROJECT. WESLEY CHAPEL, FL 33544 FAX 813-902-2516 BUILDING CODE, BUILDING THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE 4. THE CONTRACTOR IS EXPECTED TO KEEP PREMISES CLEAN jmakarfseedseng.com ALTERATION. TOTAL EGRESS WIDTH REQUIRED (63 OCCUPANTS X 02).........................13" DURING CONSTRUCTION. TRASH WILL NOT BE ALLOWED TO 2010 FLORIDA FLORIDA FIRE PREVENTION CODE PROVIDED.................................................................................................160" ACCUMULATE IN THE SPACE DURING CONSTRUCTION. ALL DEBRIS ELECTRICAL ENGINEER CHAPTER 14 - MEAN OF EGRESS MINIMUM NUMBER OF EXITS REQUIRED (FBC 1021.1).................................... 2 SHALL BE REMOVED DAILY. FINAL CLEAN UP AND REPAIR IS OTTO ENGINEERING, INC. MATT OTTO P.E. SECTION 142 EXIT ACCESS CORRIDORS: CORRIDORS USED AS EXIT ACCESS AND SERVING AN OCCUPANT LOAD EXCEEDING 30 SHALL BE SEPARATED FROM OTHER PARTS OF THE BUILDING BY WALLS HAVING NOT LESS PROVIDED AND MARKED W/EMERGENCY LIGHT SIGNAGE ....................... 4 PART OF THIS WORK REMOVE ALL DUST, DEBRIS, OILS, STAINS, FINGERPRINTS AND LABELS FROM ALL EXPOSED FINISHED�� 9385 NORTH 56TH STREET, SUITE 200 TEL 813-985-8555 THAN A 1-HOUR FIRE RESISTANCE RATING IN ACCORDANCE WITH SECTION 121 UNLESS � � �� New Exit A Width 321 SURFACES. SAFE WORKING AREA AND CONDITIONS SHALL BE TEMPLE TERRACE, FL 33611 FAX 813-985-4555 mattottosottoenginccom OTHERWISE PERMITTED BY THE FOLLOWING: L THIS REQUIKMENT SHALL NOT APPLY TO EXISTING BUILDINGS PROVIDED THAT TM OCCUPANCY CLASSIFICATION DOES NOT CHANGE Existing Exit B Width g 64 �� 'C' MAINTAINED AT ALL TIMES. s �� � x k ING Existing Exit Width g 3211 E 2. THIS REQUIREMENT SHALL NOT APPLY WHERE OTHERWISE PROVIDED IN CHAPTERS 11 THROUGH 43 OF NFPA 101:1.13.1 TOTAL— 12g" L 5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FU�11SH AND INSTALL ALL FIXTURES AND NECESSARY TO �l ' THE EXISTING SPACE IS NOT SPRINKLED WORK EQUIPMENT COMPLETE PROJECT AS PER PLANS - UNLESS NOTED OTHERWISE. THE ALL FIRE ALARM WORK, INCLUDING CHANGES, ADDITIONS, RELOCATIONS, IMPROVEMENTS, AND/OR MAXIMUM TRAVEL DISTANCE ALLOWED -FBC TABLE 1016.1 CONTRACTOR IS TO DELIVER PROJECT CLEAN AND READY FOR ( e ' MODIFICATIONS TO THE FIRE ALARM SYSTEM MUST BE DONE PER tFPA -12 200i EDITION BY A MERCANTILE....................................................................................... 150 FT. USE AS APPROVED BY TENANT/OWNER Rtt� LICENSED FIRE ALARM CONTRACTOR WITH SEPARATE PERMIT AND PLANS BUSINESS............................................................................................200 FT. 6. THE CONTRACTOR SHALL VERIFY LOCATIONS OF EXISTING UTILITIES ` -- / PLEASE REFERENCE THE CODE SUMMARY (COVER SHEET) AND BUILDING DATA SECTIONS FOR 122 FT. BEFORE COMMENCING WORK. CARE SHALL BE TAKEN TO ADDITIONAL INFORMATION. PLEASE REFERENCE THE SCOPE OF WORK FOR ADDITIONAL INFORMATION PROTECT ALL UTILITIES WHICH ARE TO REMAIN. 1 STS ALLFE SU55TITUTIONSOEFD rIN INC. R I I VT RECORD FL OR I D A FIROD UCT APPROVA S ITEMS SHALL BE SUBMITTFOR PECI�FI DWRITING TO HE AA260I0 � 9RCHITECTURE, ARCHITECT AND WILL BE CONSIDERED ONLY IF THE ALTERNATE PROPOSED IS PROVEN TO BE MORE ADVANTAGEOUS TO THE STATE OF FLORIDA DATE DESCRIPTION PRODUCT SUB CATEGORY: MANUFACTURER: MODEL/NAME: MIAMI DADE CATEGORY: APPROVAL OWNER WITH RESPECT TO DELIVERY DATE, QUALITY, OR COST. REGISTERED ARCHITECT OM2/14 REVIEW SET EXTERIOR EXTERIOR DOOR CECO DOOR SWINGING HOLLOW METAL FL4553.1 DOORS COMPONENTS PRODUCTS DOOR AND FRAME ALL VENDOR SUPPLIED ITEMS ARE EXCLUDED AND MAY NOT BE MATTHEW WIEDRICK IOA5114 PERMIT SET SUBSTITUTED. UNDER NO CIRCUMSTANCES WILL THE ARCHITECT BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY TO THE PRODUCT SPECIFIED.: REGISTRATION NUMBER: AR94577 SHUTTERS — ROLL -UP OVERHEAD DOOR Co. SECTIONAL FL 12146.1 STRUCTURAL COMPONENTS STRUCTURAL WALL BERRIDGE "THINLINE" wall panel FL 14665.5 — - e .ric Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 MR9 mid Tr PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I COVER SHEET MJW PROJECT #: 14022 G001 10/15/14 OR Q k 0 Mi", Existing Landscape Area CONDENSER PAD BY CONTRACTOR LIFE SAFETY LEGEND EXIT 111111111111 EXISTING AND/OR NEW RATED WALL ASSEMBLY. REFERENCE DETAIL 3/A100 FOR UL INFORMATION. EXISTING AND NEW EMERGENCY EXIT LIGHT FIXTURE WITH ILLUMINATED FACE. PRIMARY TENANT/BUILDING EXIT. NEW WALL MOUNTED FIRE EXTINGUISHER ADJACENT OCCUPIED TENANT SUITE. NO WORK IN THIS AREA. Resign No. U419 Non Bearing Wall Ratings-1, 2, 3 or 4 Hr (See Iterns 3 & 4) For Nw.n.Aer .and ifQurly fatinRs � ,J see Iierzi 1. 'Floor and Ceiling Runners —(Not shown) —Channel shaped, fabricated from min 2§ MSG corrosion'-p:roteeted steel, min width: to accommodate stud size, with min 1 in.. long legs, attached to floor and ceiling with fasteners 24 in. OC max. 2: Steel Studs�Channel shaped, fabricated from min 25 MSG corrosion protected steel., rain width as indicated .under Item 4, min 14/4 in. flanges and 1{4 in return:, spaced: a max o. 2�4 in. OC. Studs o be cut 3{8, to 3/4 .in, less than assembly height. 3. Batts..arxd Bra kets* :(Required a, indicated cinder Item 41) -Mine:ra:l wont batty, friction fitted between studs:and runners Min .nom thickness as indicated under Item 4. See Batts and Btaiikeis .(BKNN or BIZ}. Categories for names of Classified comparit s. 3A; Batts and Blankets' —(Optional)- Placedin stud cavities, an, glass fiber or mineral ,root insulation bearing the UL,Classification Marking as to Surfa e Burning Charactenstics:and/or Fire Resistance, See Batts and Blankets (BKNV or BZJZ) Categories for names of:CWsifie4 companies.: 4. Wallboard.Gypsum*: -:Gypsum panels with beveled, square or tapered: edges, applied vertically or horizontatty.Vertical joinU. -Centered over studs and staggered one stud cavity on apposite: sides of studs: Vertical joints in adjacent layers (multilayer systems} staggered one stud cavity, H.orizontat .edge joints 'and horizontal butt aoints a.n .opposite sides: of studs staggered a min of 12 i:ii: Horizohtat edge .joi.rrt# Anil horizontal butt.joints in adjacent tayers (mutiilayer systems.) staggered a min .of 2. in. The thickness and number of layers for the hr, 2 tir, ;3 hr and .4 hr ratings areas follows: Wallboard Protection on tach.Side of'Wall 40. of Layers Min Thttkness Min Stud And Thick ess Of`insuladon Rating Depth Of panels :(item:10) 1 3-1/2 1 1ayet 5/8 in. thick Optional. 1: 2-1;l2 I layer, 1/2 in. thick .1-1/2 in. 2 1,.5/8 2 layers, 1/2 in. thick Optional 2 1-5/8 2 layers,.5/8 in, thick dptioda.t 2 3-1/2 1 Jaye r 3/4 in, thick 3 In. 3 1-5/8 3 layers, 1/2 in, thick Optional. 3 1-5:/8 2 layers, 3/4 in. thick O..ptrona'l 4 1-5/s 4 tayers, 1/2 in. thick Optional 4 24/2 21aye:rs, 3/4 in. thick 2 in. Canadian Gypsum Co.-1/2 in. thick Type C, WRC or IP-X2; 5/8 in.. thick Type SCX, SHX, WRX, IPA.1, AR, C, WRC or IP�X2; 3/4 i:n. thick .ULTRACODE or Type IP43 United States Gypsum Co.,-1/2 in, thick Type C t .RC or TP-X2, 5/S in. thick Type SCX, SHX, WOK, iP-X.1, AIR, WRC or IP X2F 3/4 in. thick'1ATRACODE or Type IP-X3 Yeso Panamericano SA de.CV-1/2 in. thick Type C, WRC or TP42' 5/8 in. thick Type SCX, SHX, WRXr IP-X1, Alt; C, WRC or IP-X2' 3/4 in thick ULTRACObEE or Type IP-X3. 5. Fasteners —(Not shown) —Type S or S-12 self -drilling, self -tapping :steel screws: used to attach pariels to studs (Item 2) or furring channels (item 6)Single layer systems 1 in. long for 1/2 and 5/4 in. thick panels or 1 1/4 in. tong for 3/4 in, thick panels, spaced 8 in, OC when panels are applied Horizontally, or 12,in, OC when panels are applied verticatty. Two layer systems First layer- 1 in., long for 1/2 and 5/8 m. thick panels or 1 1/4 in. tong for 3/4 in. thick pants, spaced 16 in 0C.. Second layer- 1-5/8 in. tong for 1/2 in. thick panels or,Z-1/4 in. long for 3/4 +. thick. pants, spaced .16. in: OC with screws .offset 8 iv from first layer.. Three -layer systems•. First layer- 1 in long for 1/2 in. thick panels, spaced 24 in OC: Second` tayer- 1-5/8 in. Long for 1/2 in. thick panels, spaced' 24 in. OC. Third layer- 2>1/4 in, long for 1/2 in. thick panels:: spaced 12 in.. O Screws offset rain 6 iri;, :from layer below, Pour -layer sys#ems: First tayer 1 in. ton for 1/2 in. thick panels, spaced 24 in. OC.. Second layer 1-5/8 in long Tor 112 in. thick panels, spaced 24 in. OC: Third layer 24 /4 in. Long far 1/2 in. thick panels, spaced 24 in. OC,. Fourth layer- 2-5/8 in tong for 1/2 in. thick panels, spaced 12 in. OC'.. Screws :offset min 6 rn. from layer below b:, .Furring Channels —(Optional, not shown; for single or double layyer systems) —Resilient furring channels. fal r sated from rnin 25 MSG corrosion protected steel; spaced .vertically a max of 24 in. OC. Flange portion attached to each intersecting stud with 1/2 im. tong. Type S-12 panhead steel strews. 7. Joint Tape and Compound —Vinyl or casein, dry or Ipnemixed joint compound applied in two -coats to joints and screw heads of outer tayers. Paper ta�T nom: 2 in, wide, embedded in first layer of compound over. all Joints of outer panets.. 8. Siding, Brick or Stucco�(Optionat, not shown) —Aluminum, vinyL. or steel siding, brick veneer or stucco, meeting the, requirements of .Local code agencies, installed over gypsum panels, griek veneer<attached to studs with corrugated metal wall ties attached to each stud With .steel screws, not more than each sixth course of brick. 9, Caulkin4 and Sealants*- (.Qptionat, not shown —A beat) :of acoustical.. sealant applied. around the partition perimeter or sound cerntrat. United States Gypsum Ca. —Type AS *Bearing the UL Classification Marking UL 419 N.T.S. LIFE 5AFET"'� NOTE5 I. THiS PLAN iS FOR C:ENERAL INFOIRMATiON ONLY. PLEASE REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 2. INTERIOR AND EXTERIOR ELEMENTS ARE EXISTING - CONTRACTOR TO ENSURE THAT FINISH FLOOR SURFACE ELEVATIONS ARE LESS THAN 1/2" DIFFERENCE AT ALL EXTERIOR AND INTERIOR DOOR LOCATIONS. SCOPE OF UJO14`1;�'K THIS IS AN ALTERATION TO THE EXISTING FIRST FLOOR TENANT SUITE LOCATED AT 3844 5TH AVE. ZEPWRHILLS FLORIDA 33542. THE AFFECTED AREA IS APPROXIMATELY 5950 SQUARE FEET. THE EXISTING SUITE IS APPROXIMATELY 5,950 SQUARE FEET. THE PURPOSE OF THIS ALTERATION IS TO BUILD -OUT THE SPACE INTO A FUNCTIONING MIXED USE (MERCANTILE AND BUSINESS) OCCUPANCY. THE SCOPE INCLUDES MODIFICATIONS TO THE EXISTING MECHANICAL AND ELECTRICAL SYSTEMS. THIS ALTERATION IS SUBMITTED USING THE PRESCRIPTIVE METHOD AS DEFINED IN THE FLORIDA BUILDING CODE - EXISTING BUILDING. THE FOLLOWING IS A BRIEF SUMMARY OF THE APPLICABLE CODE SECTIONS FROM THE 2010 FLORIDA BUILDING CODE - EXISTING BUILDING AND THE FLORIDA FIRE PREVENTION CODE: CHAPTER ONE - SCOPE AND ADMINISTRATION SECTION 1015.1 COMPLIANCE METHODS: REPAIRS, ALTERATIONS, ADDITIONS AND CHANGES OF OCCUPANCY COMPLYING WITH CHAPTER 3 OF THIS CODE IN BUILDINGS COMPLYING WITH TIE FLORIDA FIRE PREVENTION CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS OF THIS CODE. CHAPTER 3- PRESCRIPTIVE COMPLIANCE METHOD SECTION 303 ALTERATIONS: EXCEPT AS PROVIDED BY SECTION 3012 OR THIS SECTION, ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NO LESS CONFORMING WITH THE PROVISIONS OF THE FLORIDA BUILDINGS CODE, BUILDING THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION. 2010 FLORIDA FLORIDA FIRE PREVENTION CODE CHAPTER 14 - MEAN OF EGRESS SECTION 142 EXIT ACCESS CORRIDORS: CORRIDORS USED AS EXiT ACCESS AND SERVING AN OCCUPANT LOAD EXCEEDING 30 SHALL BE SEPARATED FROM OTHER PARTS OF THE BUILDING BY WALLS HAVING NOT LESS THAN A I -HOUR FIRE RESISTANCE RATING IN ACCORDANCE WITH SECTION 12.1 UNLESS OTHERWISE PERMITTED BY THE FOLLOWING: *t THIS REQUIREMENT SHALL NOT APPLY TO EXISTING BUILDINGS PROVIDED THAT THE OCCIUPANCYCLASSIFICATION DOES NOT CHANGE 2. THIS REQUIREMENT SHALL NOT APPLY WHERE OTHERWISE PROVIDED IN CHAPTERS 11 THROUGH 43 OF NFPA 101:1.13J THE EXISTING SPACE IS NOT SPRINKLED ALL FIRE ALARM WORK, INCLUDING CHANGES, ADDITIONS, RELOCATIONS, IMPROVEMENTS, AND/OR MODIFICATIONS TO THE FIRE ALARM SYSTEM MUST BE DONE PER NFPA -12 2001 EDITION BY A LICENSED FIRE ALARM CONTRACTOR WITH SEPARATE PERMIT AND PLANS PLEASE REFERENCE THE CODE SUMMARY (COVER SHEET) AND BUILDING DATA SECTIONS FOR ADDITIONAL INFORMATION. UILD iNG [DATA BASED ON THE 2010 FBC AFFECTED AREA.............................................................................. 5,950 SF OCCUPANCY TYPE ...........................................BUSINESS AND MERCANTILE CONSTRUCTION TYPE ..................................... EXISTING (V-5) - NO CHANGE SPRINKLERED........................................................................................... NO OCCUPANT LOAD - TABLE 1004.1.1 MERCANTILE - GRADE FLOOR AREAS (100 SQFT/30 GROSS) ................ 24 BUSINESS - (3,335 SQFT/100 GROSS)........................................................ 34 KITCHEN (FRONT OF HOUSE) - OB2 SQFT/200 GROSS) .............................. 1 STORAGE - (1135 SQFT/300 GROSS).......................................................... 4 TOTALOCCUPANT LOAD........................................................................... (03 MEANS OF EGRESS TOTAL EGRESS WIDTH REQUIRED (63 OCCUPANTS X 02).........................13" PROYIDED.................................................................................................1(00" MINIMUM NUMBER OF EXITS REQUIRED (FBC 1021.1).................................... 2 PROVIDED AND MARKED W/EMERSENCY LIGHT SIGNAGE ....................... 4 New Exit 'A' Width 0.3211 Existing Exit 'B' Width 06411 Existing Exit 'Cr Width .0 32" TOTAL 128" MAXIMUM TRAVEL DISTANCE ALLOWED - FBC TABLE 1016J MERCANTILE....................................................................................... 150 FT. BUSINESS............................................................................................200 FT. PROVIDED.....................................................................I..................... 122 FT. PLEASE REFERENCE THE SCOPE OF WORK FOR ADDITIONAL INFORMATION �r. :r. `a Wiedick . . . . . . . . . . Architecture, Inc. 0 W Q 0 Q a O U W W C7 W W Z 0 a 0 W Z _ W W co J J Q WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z O ICT ai coLO > co Q J LL }' C/) Ln J J_ qq _ qct 1f oM0 = W N PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION LIFE SAFETY PLAN LIFE SAFETY PLAN 3/16 w a 1 1-011 0 ENLAR63EID SITE IMAGE "� MJW PROJECT #: 14022 Al 00 10/15/14 REQUIRED BY THE FBC DEMO FLOOR PLAN DEMOLITION NOTE5 I. THE GENERAL CONTRACTOR SHALL RIRNISH ALL LABOR AND MATERIALS REQUIRED TO COMPLETE DEMOLITION, REMOVAL AND RE -USE OF ALL ITEMS SHOWN ON DRAWINGS. 2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE PRECAUTIONS TO PROTECT BUILDING: OCCUPANTS, MATERIALS AND EXISTING FINISHES THROUGHOUT ALL PHASES OF CONSTRUCTION. OCCUPIED AREAS INCLUDING PUBLIC AREAS ARE TO BE MAINTAINED BY THE GENERAL CONTRACTOR ANY DAMAGE TO 'EXISTING-TO-REMAN" CONSTRUCTION, MATERIALS OR EQUIPMENT MUST BE RESTORED TO THERE ORIGINAL CONDITION. 3. THE GENERAL CONTRACTOR SHALL ERECT ALL NECESSARY PLASTIC DROP CLOTH PARTITIONS TO PROTECT ADJACENT BUILDING PROPERTY WHILE DEMOLITION AND CONSTRUCTION IS N PROGRESS. 4. ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES DAILY, EXCEPT ITEMS TO BE RE -USED OR RETURNED TO THE OWNER OR AS DIRECTED OTHERWISE. 5. THE GENERAL CONTRACTOR SHALL REMOVE ALL WALL CONDUITS, SWITCH PLATES, TELEPHONE OR ELECTRICAL WIRING OR EQUIPMENT, ETC. TO THE SOURCE AFTER WALL DEMOLITION. b. REFER TO THE NEW FLOOR PLANS FOR VERIFICATION OF THE EXISTING CONSTRUCTION TO REMAIN AND EXTENT OF DEMOLITION. ALL EXISTING DOORS, FRAMES, HARDWARE, CABINETRY, AND OTHER BUILDING STANDARD COMPONENTS REMOVED DURING DEMOLITION AND NOT REUSED AS A PART OF THIS WORK ARE TO BE PROVIDED TO THE OWNER - COORDINATE WITH OWNER PRIOR TO DEMOLITION. 1. NOTIFY ARCHITECT IMMEDIATELY OF ANY PIPES, POSTS, DUCTWORK, SPRINKLER LINE OR MISCELLANEOUS EQUIPMENT CONFLICTS TO NEW PARTITION AND REFLECTED CEILING PLAN AFTER DEMOLITION IS COMPLETE. 8. ALL DOORS ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. S. ALL WINDOWS ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 0 DEMOLITION KE � NOTE 5 1. EXISTING WALL AND/OR PORTION OF EXISTING WALL, STOREFRONT OR WINDOW TO BE REMOVED- SEE NEW PLAN. PATCH FLOOR AS REQUIRED FOR NEW FINISH MATERIAL. 2. EXISTING WALL FINISH MATERIAL AND FURRING TO BE REMOVED. REFERENCE NEW FLOOR PLAN. 3. EXISTING DOOR HARDWARE AND FRAME ASSEMBLY TO BE REMOVED. RETURN TO OWNER IF REQUESTED - VERIFY WITH THE OWNERS CONSTRUCTION REPRESENTATIVE. 4. EXISTING: FLOORING MATERIAL/FINISH TO BE REMOVED - PATCH SLAB AS REQUIRED. REFERENCE NEW FLOOR PLAN FOR ADDITIONAL INFORMATION. 5. EXISTING CEILING ASSEMBLY AND ALL FIXTURES TO BE REMOVED. RETAIN LIGHT FIXTURES FOR RE -USE N NEW CEILING ASSEMBLY - REF. ELEC DRAWINGS 6. ALL PLUMBING FIXTURES INCLUDING PARTITIONS TO BE REMOVED. CAP AND SEAL EXISTING PLUMBING LINES AS REQUIRED - REFERENCE NEW FLOOR PLAN AND PLUMBING PLANS FOR ADDITIONAL INFOR ATION. 1. EXISTING HOOD ASSEMBLY TO BE REMOVED. RETURN TO OWNER IF REQUESTED - VERIFY WITH THE OWNERS CONSTRUCTION REPRESENTATIVE. 8. EXISTING STAIR AND MEZZANINE STORAGE AREA TO BE REMOVED. 9. EXISTING FIRE RATED WALL ASSEMBLY TO REMAIN- REPAIR/PATCH AS REQUIRED. ALL WORK TO COMPLY WITH UL REQUIREMENTS - REFERENCE LIFE SAFETY PLAN FOR ADDITIONAL INFORMATION. PREP WALL AS REQUIRED FOR NEW TENANT FINISHES. 10. REMOVE PORTION OF EXISTING SLAB AS REQUIRED FOR NEW PLUMBING - REF. PLUMBNG PLANS FOR ADDITIONAL INFORMATIOK 11. EXISTING MECHANICAL EQUIPMENT TO BE REMOVED - REF. MECHANICAL DRAWINGS 12. EXISTING WALL ASSEMBLY TO REMAIN - PATCH AND REPAIR AS REQUIRED. 13. THE SEVEN (1) EXISTING WINDOW ASSEMBLIES IN THE EXISTING EAST WALL ARE TO BE REMOVED - REF. NEW FLOOR PLAN FOR INFILL INFORMATION. 14. EXISTING PLASTIC WALL SHEATHING AT THE TOP OF THE EXISTING EXTERIOR WALL TO BE REMOVED - REFERENCE NEW FLOOR PLAN FOR NEW INFILL INFORMATION. DEMOLITION LEGEND EXISTING WALLS TO REMAIN — — — — — — — — — EXISTING WALL AND/OR PORTION OF EXISTING WALL, — — — — — — — — — STOREFRONT OR WINDOW TO BE REMOVED. EXISTING DOOR AND FRAME ASSEMBLY TO BE REMOVED. EXISTING TWO (2) HOUR FIRE RATED WALL ASSEMBLY. REFERENCE DETAIL 3/A100 FOR UL INFORMATION. NEW 3000 PSI CONC. WPBER''IGLASS RE NFORCEMENT POUR BACK INCLUDE 03 BARS 18"LONG GTIVO.C. (STAGGERED) EACH SIDE. DRILL AND ADHERE INTO EXISTING SLAB WITH 3-1/2" EMBEDMENT WITH HILTI HIT RE-500-SD ADHESIVE SYSTEM OR APPROVED EQUAL POUR TOP OF TRENCH FLUSH TO MATCH SURROUNDING AREA. IO.ML. VAPOR BARRIER OVER ENTIRE AREA EARTH FILL COMPACTED TO S% W/TERMITE-INSECT TREATMENT. SLAB INFILL DETAIL 3/4" =1'-0" 0 W 0 a r a 0 0 H w W a W Of Z 0 0 Z Ld W W Co J Q _ F_ H Wiedrick ------------- Architecture, Inc. WIEDRICK ARCHITECTURE INC AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z� a N of) Q M LL Lid J � J � L LI Df �-�_ PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I DEMOLITION PLAN MJW PROJECT #: 14022 Al 01 10/15/14 S R-" Existing Landscape Area CONDENSER PAD BY CONTRACTOR ACOUSTIC CEILING CONTINUOUS METAL RUNNER CONTINUOUS METAL R-INNER. ATTACH WITH P RAMSET 300 DIAM NAILS 0320OC. MIN SEALANT BOTH SIDES BRACE TO STRUCTURE ABOVE WITH KICKER STUDS 645 DEGREES IN ALTERNATING DIRECTIONS AS REQUIRED OPT ION B 5/8" GWB EACH SIDE LPROVIDE J-MOLD USE MR GM AT ALL TERMINATION FOR WET AREAS OPTION B-BOTH 6" or 3 V 20 GA METAL SIDES STUDS * 16" OC. BASE AS SCHEDULED SEALANT BOTH SIDES FINISH FLOOR GENERAL CONFRUCTION NCTE5 1. REFER TO THIS SHEET FOR PARTITION TYPES AND SECTIONS. 2. PROVIDE lU FIRE EXTINGUISHER PER 30M SQUARE FEET OF USABLE OCCUPIED SPACE OR 15 FEET OF TRAVEL. 3. VERIFY ALL STRUCTURAL, MECHANICAL, AND ELECTRICAL REQUIREMENTS AND COORDINATE REQUIRED CHANGES WITH OWNER PRIOR TO CONSTRUCTION. 4. VERIFY ALL DIMENSIONS SHOWN ON PLAN, DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT WITH ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 5. PROVIDE SUFFICIENT NUMBER OF 4°-0" X V-0" X 3/4" THICK FIRE RATED SHEETS OF PLYWOOD TO HOUSE PHONE/ DATA EOJIPMENT. PAINT TO MATCH WALLS. 6. ALIGNMENT OF DOOR HEADS AND OTHER CRITICAL HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT A CONSTANT LEVEL RELATIVE TO THE CEILING PLANE. 1. WET LOCATIONS (INCLUDING TOILET AREAS, MOP AND SINK AREAS, LAUNDRY, ETC) ARE TO HAVE WALLS CONSTRUCTED WITH MOISTURE RESISTANT GWB. 8. ALL EXPANSION JOINTS IN FIRE -RATED WALLS ARE TO MAINTAIN THE ASSEMBLY FIRE RATING. 3 ALL EXISTING LOCKS AND LATCHES USED TO PREVENT THE OPERATION OF AN EXIT MUST COMPLY WITH THE 2010 FBC SECTION I008 - SPECIFICALLY SECTION 1008.IB3,1008.18.4 AND 1008.15 10. REPAIR ALL EXISTING WALLS AS REQUIRED TO RECEIVE PANT COORDINATE FINAL FINISH SELECTION WITH OWNER, IL CASEWORK IS WM FOR REFERENCE ONLY- CASEWORK IS NOT INCLUDED IN THIS SCOPE OF WORK, AND WILL BE PROVIDED UNDER A SEPARATE FUTURE CONTRACT WITH THE OWNER NEW LEGEND 000 DOOR NUMBER- REF. SHEET A600 000 I ROOM NAME/NUMBER F.E. WALL MOUNTED 10 LB. 4A605C FIRE EXTINGUISHER NEW FULL HEIGHT WALL - REFERENCE PARTITION TYPES FOR ADDITIONAL INFORMATION EXISTING WALL ASSEMBLY TO REMAIN - V.I.F. EXISTRING AND NEW FIRE RATED WALL ASSEMBLY - REFERENCE THE LIFE SAFETY SHEET FOR ADDITIONAL INFORMATION. ........................ ........................ ........................ ........................ ........................ ........................ ........................ ADJACENT OCCUPIED TENANT SPACE - MERCANTILE. NO WORK IN THIS AREA 00 WINDOW SYMBOL - REF. A ---- SEE SECTIONS UJAL L /PART I T I ON T�� 5 FOR EXTERIOR F�SHLEVATIONS 1-14R FIRE RATING: 5/6" TYPE "X" GYPSUM BOARD (EACH SIDE) ON 6" 20 GA METAL STUDS AT 16" OC., ❑1 EXTEND TO UNDERSIDE OF EXISTING ROOF DECK, FILL ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. PROVIDE MOISTURE -RESISTANT GYP BD IN WET AREAS (SEE GENERAL CONSTRUCTION NOTE 01 ABOVE). PROVIDE UL419 ASSEMBLY FOR I-HR FIRE RATING. la NON -FIRE RATED WALL ASSEMBLY - REF. DETAIL 2/A102 -- . ........... ----- - - ------ --..... ---- -.....--- - - ------------------ ----------- ---------- - --...... ......... ....- -............................................ ........... I-HR FIRE RATNG: 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) ON 3-5/8" 20 GA METAL STUDS AT 16" OC., ❑2 EXTEND TO UNDERSIDE OF EXISTING ROOF DECK, FILL ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. PROVIDE UL U41S ASSEMBLY FOR 1-14R FIRE RATING. -------............. . ........ _.......... ........................... ....................................__............... ........................ .............. _..._ ............ EXISTING WAIL ASSEMBLY v.IF. ❑3 EXISTING WALL ASSEMBLY TO REMAIN - V.IF. 5/8" GYPSUM BOARD (EACH SIDE) OVER 3-5/8" 20 GA MTL STUDS AT 16" O.C., -REF. DETAIL 2/AI02 FILL CAVITY WITH SOUND ATTENUATION BATTS. USE MOISTURE RESISTANT GWB IN ALL BATHROOMS AND OTHER WET LOCATIONS. EXISTING WALL ASSEMBLY V.IF. PROVIDE 5/8" GYP. BD. OVER 1-1/2" HAT CHANNELS AT 16" OC. EXTEND INTERIOR MATERIALS (ON EXTERIOR ❑5 WALLS) TO EXISTING ROOF DECK ABOVE. PROVIDE 5/8" MOISTURE RESISTANT GYP BD N WET AREAS (SEE GENERAL CONSTRUCTION NOTE'1 ABOVE). PROVIDE LINE ITEM FOR RIGID INSULATION BOARD - VERIFY WITH TENANTS CONSTRUCTION REPRESENTATIVE. ------ ----------- ------ -------- - ---- - -- - ----....._._.......... _....... .......................... - ...... - - - --- --------------------- --------------- 5/8" GYPSUM BOARD (INTERIOR SIDE) OVER 3-5/8" EXISTING WALL ASSEMBLY V.IF. 20 GA MTL STUDS AT 16" O.G., -REF. DETAIL 2/AI02 FILL CAVITY WITH SOUND ATTENUATION BATTS. USE MOISTURE RESISTANT GWB IN ALL BATHROOMS AND OTHER WET LOCATIONS. Wiedrick ................ Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z O LLI ICT N M M LL �--+ (n U-) J � 2 00 >- M � W J w 0 N Q 0 U H w W a Z PROJECT ADDRESS: z 38444 5TH AVE. ZEPHYRHILLS, FL 33542 W of W m J Q _ CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I ALTERED FLOOR PLAN MJW PROJECT #: 14022 Al 02 10/15/14 ALTERED FL OCR PLAN INTERIOR FAR I-1/2" = 1'-0" TITION oPtioNs a Im ol 1 VINYL FACED CEILING TILES I NEW ROLL -DOWN SHUTTER ASSEMBLY VINYL FACED CEILING TILES I REFLECTED CEILING PLAN NOTES I L CONTRACTOR MUST VISIT THE PREMISES TO CONFIRM CONDITIONS PRIOR TO SUBMITTING A COST QUOTATION. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL IrFOR1lATIOK 2. PROVIDE EMERGENCY LIGHTING, STROBES, ALARMS, FIRE PULLS AND SMOKE DETECTORS AS REQUIRED BY CODE. 3. NOTIFY ARCHITECT IMMEDIATELY OF ANY CLEARANCE Ca4FLICT6 WITH LIGHT FIXTURES DUE TO ITEMS (DUCTWORK, SPRINKLER LINES, ETC-) ABOVE CEILING. 3. 2X4 ACOUSTICAL CEILING TILE AND GRID BY ARMSTRONG OR EQUAL: • TYPE: DUNE WITH S/16" GRID BEVELED TEGULAR EDGE • CLASS A • SEE CEILING PLANS FOR ADDITIONAL INFORMATION • ALL CEILINGS TO BE 10 FT AFF UNLESS NOTED OTHERWISE. 4. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. fREPL CTE D CEILING PLAN LEGEND REFERENCE ELECTRICAL DRAWINGS FOR SPECIFIC TYPES TO BE USED. ® 2 X 4 FLUORESCENT O RECESSED COMPACT FLUORESCENT DOWNLIGHT SURFACE MOUNTED TRACK LIGHT ® EXIT LIGHT (PROVIDE DIRECTIONAL ARROWS WHERE NOT LOCATED DIRECTLY ABOVE EXIT) EMERGENCY BATTERY PACK LIGHT FIXTURE. ® SUPPLY AIR GRILLE -SEE MECHANICAL DWG'S RETURN AIR OR TRANSFER GRILLE -SEE MECHANICAL DWG'S z EXHAUST FAN -SEE MECHANICAL DWG'S SUSPENDED ACOUSTICAL CEILING GRID - SEE NOTE *3 VINYL FACED CEILING TILES 1/2" GWB CEILING OVER 3-5/8" 20GA MTL. STUDS • 1b"O.C. x'-x' CEILING HEIGHT INDICATOR 3 EXISTING ROOF STRUCTURE ABOVE V.IF. OPTIONAL CROWN MOLDING PAINTED GWB -PAINTED OVER 3-5/8" MTL. STUD FRAMING * 16" OL. DOWN LIGHT REF. ELEC DRAWINGS FIRE RATED WALL ASSEMBLY -REF PARTITION TYPES jk10'-0" A.F.F. BOT.OF A.T. C:EIL NG J,,V-211 APR IRP50T.OF: SOFF I T 6 w 0 a O U H Lu w O w m z O IL z Lu w w m J J Q _ edick .............. Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z OLo N ai M M J LL � ryLo co '�r LLJ 11, frf � 2 Q� PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I CEILING PLAN CEILING PLAN_ 3/16 . Vm EXISTING SOFFIT ASSEMBLY TO REMAIN NEW ROLL -DOWN SHUTTER ASSEMBLY DETAIL MJW PROJECT #: 14022 Al 03 10/15/14 m ,mil Existing Landscape Area r NERAL CONSTRUCTION NOTES 1. REFER TO THIS SHEET FOR PARTITION TYPES AND SECTIONS. 2. PROVIDE (1) FIRE EXTINGUISHER PER 30M SQUARE FEET OF USABLE OCCUPIED SPACE OR 15 FEET OF TRAVEL. 3. VERIFY ALL STRUCTURAL, MECHANICAL, AND ELECTRICAL REQWREMENTS AND COORDINATE REQUIRED CHANGES WITH OWNER PRIOR TO CONSTRUCTION. 4. VERIFY ALL DIMENSIONS SHOWN ON PLAN, DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT WITH ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 5. PROVIDE SUFFICIENT NUMBER OF 4'-0" X V-0" X 3/4" THICK FIRE RATED SHEETS OF PLYWOOD TO HOUSE PHONE/ DATA EQUIPMENT. PAINT TO MATCH WALLS. 6. ALIGNMENT OF DOOR HEADS AND OTHER CRITICAL HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT A CONSTANT LEVEL RELATIVE TO THE CEILING PLANE. 1. WET LOCATIONS (INCLUDING TOILET AREAS, MOP AND SINK AREAS, LAUNDRY, ETC) ARE TO HAVE WALLS CONSTRUCTED WITH MOISTURE RESISTANT GWB. S. ALL EXPANSION JOINTS IN FIRE -RATED WALLS ARE TO MAINTAIN THE ASSEMBLY FIRE RATING. 9 ALL EXISTING LOCKS AND LATCHES USED TO PREVENT THE OPERATION OF AN EXIT MUST COMPLY WITH THE 2010 FBC SECTION 1008 - SPECIFICALLY SECTION 100823,1008.1.8.4 AND 1008.15 10. REPAIR ALL EXISTING WALLS AS REQUIRED TO RECEIVE PANT COORDINATE FINAL FNISH SELECTION WITH OWNER 11. CASEWORK IS SHOWN FOR REFERENCE ONLY- CASEWORK IS NOT INCLUDED N THIS SCOPE OF WORK, AND WILL BE PROVIDED UNDER A SEPARATE FUTURE CONTRACT WITH THE OWNER NEW LEGEND 000 DOOR NUMBER- REF. SHEET A600 000 I ROOM NAMEM15ER F.E. WALL MOUNTED 10 LB. 4A60BC FIRE EXTINGUISHER NEW FULL HEIGHT WALL - REFERENCE PARTITION TYPES FOR ADDITIONAL INFORMATION EXISTING WALL ASSEMBLY TO REMAIN - v.IF. EXISTRING AND NEW FIRE RATED WALL ASSEMBLY - REFERENCE THE LIFE SAFETY SHEET FOR ADDITIONAL INFORMATION. ADJACENT OCCUPIED TENANT SPACE - MERCANTILE. NO WORK IN THIS AREA. 0la WINDOW SYMBOL - REF. A ---- SEE SECTIONS W A L� F A IRT I T I ®N T�� 5 FOR EXTERIOR��ILEVATIONS I-HR FIRE RATING: 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) ON 6" 20 GA METAL STUDS AT 16" O.C, ❑I EXTEND TO UNDERSIDE OF EXISTNG ROOF DECK, FILL ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. PROVIDE MOISTURE -RESISTANT GYP BD N WET AREAS (SEE GENERAL CONSTRUCTION NOTE 01 ABOVE). PROVIDE UL419 ASSEMBLY FOR 1-HR FIRE RATNG. la NON -FIRE RATED WALL ASSEMBLY - REF. DETAIL 2/A102 ------- ------------ -------------------------------------------------- --------..--------------------------------..-.-.--------------------------------------------------------------- 1-HR FIRE RATING: 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) ON 3-5/8" 20 GA. METAL STUDS AT 16" O.G., �2 EXTEND TO UNDERSIDE OF EXISTNG ROOF DECK, FILL ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. PROVIDE UL U415 ASSEMBLY FOR 1-14R FIRE RATING. EXISTING WALL ASSEMBLY V.IF. I1 EXISTING WALL ASSEMBLY TO REMAIN - V.I.F. 5/8" GYPSUM BOARD (EACH SIDE) OVER 3-5/8" ❑4 20 GA MTL STUDS AT 16" O.C, -REF. DETAIL 2/AI02 FILL CAVITY WITH SOUND ATTENUATION BATTS. USE MOISTURE RESISTANT GW6 IN ALL BATHROOMS AND OTHER WET LOCATIONS. -- - --- ----- --- ------------------------ --- ....................... ---------------------------- ----------- --- --- ................._....------.............. ---- -- ... EXISTING WALL ASSEMBLY V.IF. PROVIDE 5/8" GYP. BD. OVER 1-1/2" HAT CHANNELS AT 16" O.G. EXTEND INTERIOR MATERIALS (ON EXTERIOR WALLS) TO EXISTNG ROOF DECK ABOVE. PROVIDE 5/8" MOISTURE RESISTANT GYP BD IN WET AREAS (SEE GENERAL CONSTRUCTION NOTE 01 ABOVE). PROVIDE LINE ITEM FOR RIGID INSULATION BOARD - VERIFY WITH TENANTS CONSTRUCTION REPRESENTATIVE. -- ---- - ----- --------------- _.._ ................ - --- - - - - - ---- ......... _........ ......... 5/8" GYPSUM BOARD (INTERIOR SIDE) OVER 3-5/8" EXISTING WALL ASSEMBLY V.IF. 20 GA MTL STUDS AT I6" OG, -REF. DETAIL 2/A102 FILL CAVITY WITH SOUND ATTENUATION BATTS. USE MOISTURE RESISTANT GWB IN ALL BATHROOMS AND OTHER WET LOCATIONS. Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z O Q LLj N IZT N M Q M LL L 00 >- M n w LLI J 0 N a 0 U F w w w z PROJECT ADDRESS: w 38444 5TH AVE. ZEPHYRHILLS, FL 33542 w w w m J J Q _ CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I FURNITURE PLAN MJW PROJECT #: 14022 Al 04 10/15/14 FURNITURE FLAN N 1021 mol, m 1"' m 01 roll 6" Will Oo O MEN o WOMEN o ON ON MEN-H.C. A' u- UJOMEN - H C `" LL 8° v v NO SMOKING SIGNS W-M ARE TO BE 1W TONED BALwaWW Nv U NTE O SYMBOLS AND LETTRWs. LETTERNG 15 ALSO MADED N BRAILLE. MOW CN NTERIOR OF RESTRX M - MMNATE N O SMOKING 0 UN 01WR FOR EXACT LOCATIM , REFROOM 5IGNAGE 3"=1'-0" ELEVATION A l'-roll FfG 3 2 HT. SLATE PIPES 1'-6" PUBLIC BATHROOM ELEVATIONS 3/8" =1' -0" EXISTING ROOF ASSEMBLY V.IF. CONT. SEALANT NEW METAL WALL PANEL OVER (2) LAYERS 150 FELT MECHANICALLY FASTENED TO 5/8" MIN EXTERIOR GRADE SHEATHING OVER 20 GA 6" METAL STUDS ,1116" O.G. - STAGGER STUDS AS REQUIRED FOR INTERIOR AND EXTERIOR FINISH ALIGNMENT. CONT. SEALANT EXISTING WALL ASSEMBLY V.IF. O U_ LU z LL OP I VINYL COVE BASE -TYP ELEVATION B 6'-roll EXISTING METAL ROM AftMeLY V.I.F. INFILL TOP OF EXISTING WALL ASSEMBLY WITH NEW 20 GA 6" METAL STUDS 4016"O.C. EXTEND NEW GWB (REF. WALL TYPE 5) TO UNDERSIDE OF EXISTING ROOF ASSEMBLY- DILL WALL CAVITY WITH R-IS INSULATION. . ............ ... ... THIN -LINE METAL WALL PANEL BY BERRIDGE OR EQUAL. FL9466%91 FINAL SELECTION AND COLOR TO BE J VERIFIED BY THE OWNER PRIOR TO PURCHASE AND/OR INSTALLATION . k .N w x_ w NEW CEILING ASSEMBLY. SEE PLAN DETAIL. CEILING ASSEMBLY AS SCHEDULED VINYL COVI BASE -TYP ELEVATION C ro'-roll Lg3j:-�1111 A PIPES DETAIL TOILET ACC S 5 O R" SCHEDULE (APPROVED ALTERNATES ARE ACCEPTABLE KEYO DESCRIPTION MANUFACTURER/MODEL REMARKS TOILET TISSUE DISPENSER BRADLEY - MODEL 508 IN STANDARD STALL SURFACE MOUNT- INCLUDE THEFT RESISTANT SPINDLE (-52) 1 PROVIDE BLOCKING AT FRAME WALLS IA TOILET TISSUE DISPENSER BRADLEY - MODEL 523 DOUBLE ROLL IN ACCESSIBLE SURFACE MOUNT- INCLUDE THEFT RESISTANT SPINDLE (-52) STALL PROVIDE BLOCKING AT FRAME WALLS BAT= BRADLEY - 800 SERIES -MOUNTING HEAVY DUTY SERIES 36" AND 42" LONG BARS 2 M 812 - STAINLESS STEEL 1 1/2" DIA. PROVIDE BLOCKING AT FRAME WALLS g IS"x30" MIRROR BRADLEY - 100 SERIES -MODEL 140-1830 ADA COMPLIANT PROVIDE BLOCKING AT FRAME WALLS 4 SOAP DISPENSER BRADLEY - MODEL 6562 (wall mounted) ADA COMPLIANT PROVIDE BLOCKING AT FRAME WALLS 5 TOWEL DISPENSER BRADLEY -MODEL 2442-10 (SEMI RECESSED) ADA COMPLIANT PROVIDE BLOCKING AT FRAME WALLS 6 TOILET fROOM NOTES: 1. TOILET ROOM SIGNAGE: 2. FLOORS SHALL HAVE A SMOOTH, HARD, NONA15WR15ENT SURFACE PROVIDE THE FOLLOWING ADA-APPROVED SIGNAGE AT EACH THAT EXTENDS UPWARD ONTO THE WALLS AT LEAST 6 INCHES. TOILET ROOM AS MANUF. BY SCOTT SIGN SYSTEMS, SARASOTA, FL. (I-800-231-S441 EXT. 208), OR EQUAL AS APPROVED BY 3. WALLS WITHIN TWO (2) FEET OF URINALS AND WATER CLOSETS SHALL ARCHITECT: NAVE A SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OF OMEN" AND "WOMEN" W/ INTERNATIONAL HANDICAP SYMBOL. FOUR (4) FEET ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL *WALL -MOUNT AT LATCH SIDE OF DOOR ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A *INSTALL W/ HIGH BOND TAPE - MOUNT AT 60" FROM FINISH FLOOR TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. TO CENTERI--INE OF SIGN. COORDINATE ALL MILLUJORK AND FINISHES WITH THE TENANTS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND/OR INSTALLATION BUILDING V.IF. CANOPY V.IF. NEW ROLL -DOWN SHUTTER ASSEMBLY - FULL WIDTH OF EXISTING STOREFRONT ASSEMBLY. COORDINATE FINAL SELECTION AND FINISH WITH THE TENANTS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND OR INSTALLATION. SUBMIT SHOP DRAWINGS FOR REVIEW. MODIFY EXISTING SILL ASSEMBLY AS REQUIRED TO ALLOW DOOR ASSEMBLY TO CLOSE PROPERLY. VERIFY WITH OWNERS CONSTRUCTION REPRESENTATIVE EXISTING SIDE WALK V.I.F. ENLARGED PLAN Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 M Q(y) J :5LL Lo J � 2 00 >_ M � W J W 0 N Q a }a O U H U W O W a PROJECT ADDRESS: W 38444 5TH AVE. ZEPHYRHILLS, FL 33542 W W Co Q CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I ENLARGED PLANS MJW PROJECT #: 14022 1" =1' -0" O \NOV& I mm A Rom A400 10/15/14 �M 1 "0 0> a }- VERIFY HEIGHT WINDOW TYPE 4c> NOTES: I. COORDINATE WITH TENANTS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND OR INSTALLATION. VERIFY FRAME, COLOR AND FINISH. OTEMPERED GLASS INTERIOR ELEVATION NEI a _I N 21-0" ol 0 N ADJUSTABLE SHELVES ON RECESSED STDSJCLIPS w -CABINET PULL ,sTANLEr o lu _N 4484 ALUM. OR EQUAL N -OPTIONAL MICROVE SHELF - g COORDINATE ELECTRICAL RECEPTACLE LOCATION FOR ALL INTERIORS OF UPPER 4 LOWER CABINETS LINED WITH WHITE MELAMINE Q COORDINATE WALL FINISH w WITH OWNERS CONSTRUCTION e w REPRESENTATIVE PLASTIC LAMINATE ON 2' lu LAYERS 3/411 PLYWOOD z ALL EXPOSED SURFACES 4 RETURNS TO BE PLASTIC LAMINATE ON 3/4" PLYWD. -n 0 VINYL BASE v 2'-811 ALIGN WINDOW HEADS WITH DOOR FRAMES e a VERIFY HEIGHT cK1 B WINDOW TYPE MILLWORK DRAWINGS ARE FOR DESIGN INTENT ONLY. G.C. IS REQUIRED TO SUBMIT SHOP DRAWINGS, WITH FIELD VERIFICATION MEASUREMENTS FOR APPROVAL PRIOR TO FABRICATION. COORDINATE ALL MILLWORK AND FINISHES WITH THE TENANTS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND/OR INSTALLATION 2'-0" LAMINATE COUNTERTOP W/ 4"H CONT. BACKSPLAS14 LAMINATE FACE INSULATE PIPES FOR ADA PROTECTION 0 T INTEGRAL KICK FOR CIA ADA ACCESSIBILITY TO BE AT ALL SINK LOCATIONS VINYL BASE v 4" C A-401 -------------------------- ---- �LT -------------------- TJI ROLL DOWN SHUTTER DOOR ASSEMBLY 141-011 LOCATED IN THE CEILING N� ASSEMBLY BEYOND. I I 3'-011 ADA COUNTER PHARMACY WINDOW PHARMACY OPEN TO BEYOND 0 LAMINATE CCt NTERTOP UU 4"H CONT. BACKSPLASH LAMINATE FACE SEE FIN. SCa-IED. c:C, TO PRZMDE °C LNOERCOWER &P oRTs SIZE AM SPACE As REWIFIED TO ACCCMMODATE EOIJIFMT. x PROVIDED BY 04bER i EXISTING ROOF ASSEMBLY ABOVE V.IF. I I ROLL DOWN SHUTTER DOOR ASSEMBLY LOCATED IN THE CEILING ASSEMBLY - COORDINATE DOOR SELECTION WITH THE OWNERS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND/OR INSTALLATION. ^ PHARMACY SIDE C PHARMACY WINDOW SECTION MILLWORK NOTES I. ALL MILLWORK SHOWN ON DRAWINGS TO BE IN ACCORDANCE WITH AWI STANDARDS FOR CUSTOM GRADE. 2. ALL MILLWORK TO BE 3/4' PLYWOOD, FRAMELESS CONSTRUCTION WITH ALL EXPOSED SURFACES AND RETURNS TO BE PLASTIC LAMINATE, UNLESS OTHERWISE NOTED. 3. ALL INTERIOR OF CABINETS AND DRAINERS TO BE WHITE MELAMINE LINER 4. ALL HARDWARE TO BE AS FOLLOWS: • 4' WIRE PULLS WITH BRUSHED SATIN FINISH MOUNTED HORIZONTALLY. • ALL DRAWER GLIDES TO BE HEAVY DUTY, FULL EXTENSION GLIDES WITH STEEL BALL -BEARINGS. • CONCEALED HINGES. • CLEAR RUBBER BUMPERS MOUNTED AT ALL INSIDE FACES OF ALL DRAWERS AND DOORS. • ALL SHELVING TO BE ON ADJUSTABLE RECESSED STANDARDS AND CLIPS • TILT DRAWERS AT SINK LOCATIONS. 5. ALL SINK LOCATIONS TO HAVE INTEGRAL TOE KICK BUILT IN TO CABINET DOORS FOR ADA COMPLIANCE. INSULATE PIPES AS REQUIRED. 6. ALL SINKS TO BE STAINLESS STEEL WITH GOOSENECK FAUCET, HOT AND COLD WATER WITH LEVER HANDLES 1. MILLWORK DRAWINGS ARE FOR DESIGN INTENT ONLY. GL IS REQUIRED TO SUBMIT SHOP DRAINGS, WITH FIELD VERIFICATION MEASIJRNTS FOR APPROVAL PRIOR TO FABRICATION. S. ALL OUTLETS ABOVE COUNTERTOPS TO BE MOUNTED AT 44" AFF_ GF.I.OUTLETS NEAR WET AREAS. OUTLETS COVER -PLATES TO BE FLUSH WITH FACE OF RILL HEIGHT BACK SPLASHES. MILLWORK DRAWINGS ARE FOR DESIGN INTENT ONLY. G.C. IS REQUIRED TO SUBMIT SHOP DRAWINGS, WITH FIELD VERIFICATION MEA&AM ENTS FOR APPROVAL PRIOR TO FABRICATION. COORDINATE ALL MILLWORK AND FINISHES WITH THE TENANTS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND/OR INSTALLATION 31-311 101_b" Wiedrick Architecture, I nc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z O LLI N d- N M M J ILL J J_ _ qql 00 >_ M 2� W w 0 N a a a 0 U H w W 0 w _ Z COL PROJECT ADDRESS: Z 38444 5TH AVE. W ZEPHYRHILLS, FL 33542Uj J a CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I DETAILS SECTION 5ECTION SECTION INTERIOR ELEVATION fAll' MJW PROJECT #: 14022 A401 10/15/14 ROOM FIN15H 5CHEDULE FiNi5H NOTE5 DOOR NOTE5 DOOR 5CHEE)ULE ROOM FLOOR BASE WALLS WALL FINISH CEILING OTHER REMARKS L COORDINATE AND VERIFY ALL FINISHES WITH OWNER'S CONSTRUCTION REPRESENTATIVE PRIOR L COORDINATE WITH OWNERS CONSTRUCTION REPRESENTATIVE Or FINAL SELECTION OF ALL DOOR DOOR FRAME GENERAL TO PURCHASE AND/OR INSTALLATION OF ANY MATERIAL DOORS, FINISH AND HARDWARE PRIOR TO PURCHASE AND/OR INSTALLATION LOCATION DIMENSIONS }.IOW REMARKSMOTES 2. AT ALL DRYWALL: TAPE, FILL AND SAND EXPOSED DRYUI4LL JOINTS AND SURFACES TO 2. PROVIDE SILENCERS IN ALL INTERIOR HOLLOW FETAL FRAF'ES. NO. WIDTH HEIGHT 1`4-11GiG. n'M MAT'L FIN. MAT'L FIN. SILL JAMB HEAD SET z p PRODUCE A SMOOTH UN-TEXiUREIP SURFACE, PRIMED AND READY FOR SPECIFIED FINISH. 4 0� FEATHER COATS ONTO ADJOINING SURFACES SO THAT CAMBER IS MAXIMUM V32 NCH ALL WORK 3. HARDWARE SCHEDULE PROVIDED FOR PRICING AND BIDDNG DOSES ONLY. CONTRACTOR W SHALL BE N ACCORDANCE WITH GYPSUM ASSOCIATION SPECIFICATION GA 216. FINISH AS TO VERFFi' FINAL SELECTION OF ALL DOOR HARDWARE WITH THE OWNERS CONS'iRJCTION PRIOR Ul SPECIFIED. t0 PURCHASE AND/OR INSTALLATION. 102 COFFEE LOUNGE 1-3/4" C N SCWD T.B.D. HM)( TAD.- . I/A600 VAbW 14W-4 FIRE RATED DOOR AND FRAME ASSEMBLY SM 3. ALL EXPOSED C CREEiE OR MASONRY WALL SURFACES SHALL BE CLEANED, SEALED AND 103 PRIMACY SALES EXISTNG EXISTING VAb00 VA600 w Z -. WALLS PAINTED. SIM += 4 W 104 PHARMACY 3'-0" 1'-0" 1-3/4" C SCWD TBD. HM. TBD. - I/Ab00 VA600 HW-4 SPECIALITY DOOR - COORDINATE UNTH OWNERS p 4. USE MOISTURE RESISTANT GUU9 AT ALL WET LOCATIONS AND USE DENSSHIELD BEHIND ALL SIM CONSTRUCTION REPRESENTATIVE � CERAMIC WALL TILE U W § Ql _j w Q O 4 im5 WOMENS BATHROOM 3'-m" 1'-m" 1-3/4" C SCWD TAD• HIM. TAD. - VAb00 UA&00 HW-2 m 5. ALL INTERIOR TRIM PANT t0 BE SEMI GLOSS - VERIFY ALL COLORS WITH THE OIaWS SIM U u J U 4 4 U ~ 0it CONSTRUCTION �SENTATIVE PRIOR TO PLI CHIASE AND/OR INSTALLATION. I0b FENS BATHROOM 31.011 1-01-3/4" C SGUJD TAD. 141'L TAD. I/A600 UAb00 14111-2 aim(a ~ ~ 6. ROOM SKaNAGE PACKAGE: PROVIDE FOR ADA-APPROVED SWAM AT EACH ROOM AS MANWF. ul NO. NAME uWy� V } U uu�� - 4 u� C BY SCOTT SIGN SYSTEMS, SARASOTA, FL (I-800-231-9441 EXT.20S), OR EQUAL AS 108A ADMIN 3'-0" 1'-0" 1-3/4" D MTL. TBD. HM TOD. UA601 3/A601 I/A601 HW-1 PROVIDE CLOSER DOOR SWEEP, ADA THRESHOLD U U } v U l7 E U U _ w APPROVED BY ARCHRECT: Al2A APPLIQUE SKINS. FINAL SELECTION TO BE MADE BY OWNER SIM METAL RAN GUARD. PROVIDE WEATHER-STRIPS FRIOR TO PURCHASE AND OR INSTALLATION. COORDINATE WITH BUILDING INFORMATION 1085 ADMN 3'-0" 1'-0" 1-3/4" C x SCWD TBD. HUM.)( Tars. - I/A600 1/A600 14111-1 FIRE RATED DOOR AND FRAME ASSEMBLY BOARD ON FIRST FLOOR- VERIFY MODEL t LOCATION OF BOARD WITH OWNER. I SM 101 SALES • • • • • • EPDXY PANT 1. PROVIDE ROORNG TRANSITION STRIPS AS REWIRED - COMPLY WITH ALL ADA MWIFeWS. 109 OFFICE 3'-0" 1'-0" 1-3/4" C SCWD TAD. HM. TAD. - VAb00 IISim 00 HW-4 102 COFFEE LOUNGE • • • • • • S. PROVDnCOfMWAIARDS AT ALL EXPOSED GYP BD EDGES - COORDINATE WITH OWNER'S 110 OFFICE 3'-0" 1'-0" 1-3/4" C x SCWD TAD. HM.if TAD. - I/Ab00 VA600 ON REP I HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY CONST103 PHA141ACY SALES • • • • • • 111A CO fERINCE ROOM N-0" 1'-0" 1-3/4" C x So= TAD. N.M.)( TAD. - I/Ab00 VA600 1I19-4 FIRE RATED DOOR AND FRAME ASSEMBLY Sim 104 PHARMACY • • • • • • EPDXY PANT 1115 CAfERENCE RDOM 3'-0" 1'-0" 1-3/4" C X SCWD TAD. Hit)( TAD. - VA600 VA600 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY SM 105 WOMENS BATHROOM • • • • � • EPDXY PANT 112 SALES 3'-0" 1'-0" 1-3/4" C SCWD TAD. HIM. TAD. - VAb00 UA600 1I19-4 I aim Imb M M BATHROOM • • • • • • EPDXY PANT 113 STORAGE 3'-0" 1'-0" 1-3/4" C S= TAD. HUM. TAD. - VAb00 VAb00 HW-3 SM 101 TOILET VESTIBULE • • • • • • HARDWARE I I I /� 114 ACCOINTING 3'-0" 1'-0" 1-3/4" C x SCWD TAD. HM.x TAD. - I/A600 VA600 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY 108 ADMIN • • • • • • HART-/ WARE GROUP5 116 ONCE 3'-0" 11-0" 1-3/4" C X ALUM TAD. HM.X tAD. - I/A600 VA600 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY 109 OFFICE • • • • • • HW-1 SCHLAGE EXTRA HEAVY DUTY COMMERCIAL ND -SERIES HW-4 SCWLAGE EXTRA HEAVY DUTY C 1"ERCIAL ND -SERIES HW-1 SCHLAGE EXTRA HEAVY DUTY COMMERCIAL ND -SERIES INDWEL, In RPH 3'-0" 1'-0' 1-3/4" G iE SOUND TAD. HM. X TAD. - I/A600 VA600 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY INIDIO, ANSI FTS, PASSAGE LATCH FUNCTION, RHODES ND509), ANSI FS$ ENTRANCE/ONCE LOCK FUNCTION, ELECTRICALLY LOCKED (FAIL SAFE), RdODES ADA LEVER I Sim 110 ONCE VER • • • • • • ADA LE"OLEO, %26 SATIN CHROME FINISH BOTH RHODES ADA LEVER HANDLES, %26 SATIN CHROME HANDLES, %26 SATIN CHROME FINISH. 118 PIC LAB 3'-0" SCWD TAD. 1-3/4" C STAD. HM. TAD. - I/A600 VAb00 HW-1 LEVERS ALWAYS UNLOCKED. CLOSER SILENCERS, WALL FINISH F1JSH-BUTTON LOCKING - FUSH-BUTTON LOCKS PROVIDE KEYLESS ENTRY (TRIBE ADJUSTABLE STRIKE 2012, SATIN I Sim III CONFERENCE ROOM • • • • • • • OR FLOOR STOP. OU T TIDE LEI VER LWILEVER SILENCERS, WALLBY AL(IMHJM OP OR LEVER FROINISH, T L SAFEALWAYS W CHARACTERISTICS OR EQUAL) IMA LAB 3--m" 1'-0" 1-3/4" C iE SCWD TAD. HM.x TAD. - VA600 VAb00 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY OCKED FLOOR STOP AS APPLICABLE. LEVER FROM EXTERIOR ALWAYS LOCKED, UNLESS ACCESS IS Sim 112 SALES OBTAINED THROW KEYLESS ENTRY 1195 LAB 3'-0" 1'-0" 1-3/4" C SCWD TAD. H.M. TBD. - I/A600 VA600 14W-4 • • • • • • 14W-2 SCHLAGE EXTRA HEAVY DUTY COMMERCIAL ND -SERIES PROVIDE CLOSER SILENCERS, DOOR STOPS 416' 14W X 34' 1 Sim 113 STORAGE ND406, ANSI Fib, 5AT14 PRIVACY LOCK FUNCTION, 14W-5 DMZr/EXIT ASSEMBLY BY ALUMINUM STOREFRONT WIDE STAINLESS STEEL KICKPLATE ON PUSH SIDE OF DOOR 1� ,� �� - • • • • • • RIMES ADA LEVER HANDLES, %26 SATIN 0 RCM MA4FACTURER ADA PUS MRILL HANDLES, TURN -BUTTON 119C LAB 3 -0 1-0 1-3/4 C iE SCWD TAD. HM. iE TAD. I/A600 VA600 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY FINISH PUSH-BUiTON LOCKING - CAN BE OPENED FROM MORTISE LOCK CLOSER WEATHERSTRIPS, ADA 114 ACCOJNTNG OUTSIDE WITH SMALL SCREWDRIVER - TUJRrUNG INSIDE THRESHOLD, DOOR SWEEP 14W-8 SCHILAGE EXTRA HEAVY DUTY COMMERCIAL N P-SERIES'ND66PD, 120 LAB 3'-0" 1'-0" 1-3/4" C SCWD TAD. HM. TAD. - I/A600 VA600 14W-4 • • • • • • LEVER OR CLOSING DOOR RELEASES BUTTON. CLOSER ANSI PSI, STORE LOCK RHODES ADA LEVER HANDLES, %26 SATIN I I SM IS CORIJDM SILENCERS, WALL OR FLOOR STOP WHERE APPLICABLE. HW_6 IVES 6303 PULL PLATE WITH 1' DIA ROUND BAR IV CHROME FINISH. KEY N EITHER LEVER LOCO OR UNLOCKS BOTH 121 DISPENSING 3'-0" 1'-0' 1-3/4" C SCWD TAD. HM. TBD. - I/A600 V00 HW Ab-4 • • • • • • CENTER TO CENTER, SATIN RO CHMIE FINISH LEVERS PROVIDE CLOSER DOOR Sulam ADA THRESHOLD, HUJ-3 SCHLAGE EXTRA HEAVY DUTY COMMERCIAL ND -SERFS IVIES 8200 PUSH PLATE: 3'XI2 , BATH CHROME FINISH WEATHERSTRIPS, METAL RAN GUARD, 6' HIGH X 34' WIDE Sim Ilb 01=10E • • • • • • TDeOPD, ANSI Feb, STOREROOM LOCK FUNCTION, PROVIDE CONVENTIONAL CYLINDER (WITH THUM1B'-TWJFIN ON STAINLESS STEEL LATE KICKPLATE PUSH SIDE OF DOOR J V4' 122 SHIPPING 3'-0" 1'-0' 1-3/4° C SCWD TAD. HM. tAD. - I/A600 VA600 HIU-4 RHODES ADA LEVER HANDLES, %26 SATIN CHROME INTERIOR), CLOSER SILENCERS, DOOR STOP 4 p' HIGH X THICK DIAMOND ELATE KICKPLATE 8 HIGH X 40' WIDE INSTALLED Sim In RPH • • • • • EPDXY PANT FINISH OUTSIDE LEVER FIXED - ENTRANCE BY KEY 34' WIDE STAINLESS STEEL KICKPLATE ON PUSH SIDE OF ON CMIJ BELOW DOOR 123A IT 3'-m" 1'-0" 1-3/4" C SCWD TAD. HM. TAD00 . - I/A6VA600 HW-4 ONLY - NSIDE LEVER ALWAYS UNLOCKED. CLOSER DOOR Sim 118 PIC LAB • • • • • • EPDXY PANT SILENCERS WALL OR FLOOR STOP WHERE APPLICABLE SCWD SOLID CORE WOOD DOOR 12313 IT 3'-0" 1'-0" 1-3/4" C SCWD TAD. HM. TAD. - VA600 VA600 HW-4 aim HM HOLLOW METAL US LAB • • • • • EPDXY PANT N FIRE RATED A88EMIDLY (1-HOIR iMW 124 BREAK ROOM PR. 3'-0' 1'-0" 1-3/4" C SCWD TAD. W.M. TAD. - I/A600 VA600 Hp-4 %� 1�P 5 aim LAB • • • • • EPDXY PANT DOOR FRAME T I 125A STORAGE 3'-0" 1'-0" 1-3/4" C S= TAD. HM. TAD.- I/A600 I/S 00 HIW-3 121 DISPENSING • • • • • • EPDXY PANT 1255 STORAGE 3'-0" 1'-m' 1-3/4" C SCWD TAD. HM. TAD. 1/A601 3/A601 IIA601 NW-3 " SIM SIM SIM 122 SHIPPING • • • • • • EPDXY PAIN - 3'-0" tt 123 IT • • • • • • 124 BREAK ROOM • • • • • • EPDXY PANT 125 STORAGE • • • • • • u LU U_ L! 126 STORAGEi V LL_ U • • • • • • 0 0 0 w = _ O 0 [1 DOOR TYPE (A) DOOR TYPE © DOOR TYPE © DOOR TYPE QD FRAME TYPE 0 FRAME TYPE ALUM STOREFRONT NOT USED STAIN GRADE SOLiD PAINTED HOLLOW PAINTED HOLLOW PAINTED HOLLOW W/IMPACT GLASS GORE WOOD - FIRE METAL METAL - FIRE RATED METAL - FIRE RATED RATED AS REQUIRED AS REQUIRED AS REQUIRED GENERAL NOTES: 1. ALL EXTERIOR STOREFRONT WINDOWS, CURTAIN WALLS, AND DOOR FRAMES ARE TO BE ATTACHED TO THE STRUCTURE PER KOA DETAILS. 2. PROVIDE FIRE RATED DOOR ASSEMBLIES AS REQUIRED - REFERENCE FLOOR PLAN O IMPACT GLASS MATERiAL5 5ELECTION 5CHEDULE COORDINATE ALL MATERIALS WITH THE OWNER PRiOR TO PURCHASE AND/OR INSTALLATION MARK DESCRIPTION SELECTION - MANUFACTURER FURNISH INSTALL REMARKS CARPET 12 FT WiDE BROADLOOM CARPET PATT: TBD COLOR: TBD G.C. G.C. PATTERNED, CUT PILE/ LOOP, f26.00/SQYD MATERIAL/INSTALL ALLOWANCE CERAMIC TILE CERAMIC TILE (SIZE TBD) THROUGH BODY PORCELAIN TILE G'C' G'C' 1/4" GROUT LINES, PATTERNED LAYOUT, COLOR: TBD GROUT: TBD $12.00/SQFT MATERIAL/INSTALL ALLOWANCE VCT VINYL COMPOSITE TILE TARKETT OR EQUAL, COLOR: TBD G.C.G.C.PROVIDE NECESSARY REDUCER STRIPS, s3.00/SQFT MATERIAL/INSTALL ALLOWANCE G-1 GROUT COLOR TO MATCH TILE G.G. G.G. MILDEW AND STAIN RESISTANT ADDITIVES, SEALED: T5-1 TILE BASE THROUGH BODY PORCELAIN COLOR: TBD G.C.G.C.1/4" GROUT LINES, ALIGN WiTH FLOOR GROUT LINES V5-1 4" 14 VINYL BASE ROPPE OR JOHNSONITE, TIGHTLOCK COLOR: T50 G.C.G.C.ICOVE BASE, CONTINUOUS ROLL GOODS C15-1 4" H CARPET BASE MATERIAL TO MATCH CARPET G.C.G.C.PROVIDE FINISH/80UND ENDS - COORDINATE WITH OWNER GYP. BD. PTD GYPSUM BOARD PAINTED - G.C.G.C.MOISTURE RESISTANT AT ALL WET LOCATIONS ACT-1 2'X2' ACOUSTICAL CEILING TILE/ WHITE GRID ARMSTRONG CEILINGS, CIRRUS, 9/16" GRID G.G. G.C.BEVELED TEGULAR EDGE, CLASS A CORNER GUARD TBD TBD G.C. G.C. PROVIDE AT ALL EXPOSED GYP BD EDGES - COORDINATE WITH OWNER'S CONSTRUCTION REP MiNI- BLINDS TBD TBD OWNER G.G. COORDINATE WITH OWNER'S CONSTRUCTION REP PT-1 WALL PAINT, SATIN FINISH SHERWIN WILLIAMS, G.C. G.G. COORDINATE WITH OWNER'S CONSTRUCTION REP COLOR TBD PT-2 ACCENT WALL PAINT, SATIN FINISH SHERJJIN WILLIAMS, G.G. G.C. COORDINATE WITH OWNER'S CONSTRUCTION REP COLOR TBD PT-3 DOOR FRAME ,PAINT, SEMI GLOSS FINISH SHERWIN WILLIAMS, G.C. G.C. COORDINATE WITH OWNER'S CONSTRUCTION REP COLOR: TBD PT-4 EPDXY PAiNT SHERWIN WILLIAMS, G.C. G.C. COORDINATE WITH OWNER'S CONSTRUCTION REP JAMB DETAIL 3" = 1'-0" FRAME W/ l4) :HORS PER JAMB JT. BEAD SILICONE 1LANT JBLE STUDS At JAMB JT. BEAD SILICONE 1LANT 6 w a 0 Q a O U H U) w O w Z O 0 W Z D w w Ir m J J Q .,iedrick Architecture, Inc. _01 WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z O a N Lo M QCM_j LL � Lo J � J LLIIt � _ PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I FIRST FLOOR FINISH 4 DOOR SCHEDULES MJW PROJECT #: 14022 A600 10/15/14 1 mmf \ r El\\7\2001111 Ell1 EXISTIWs BRICK WAINSCOT v v ZIOR Y V.IF. CONT. SILICONE SEALANT AND BACKER ROD HM DOOR CONT. SILICONE SEALANT AND BACKER ROD 5/8" GWB OVER 1-1/2" MTL FURRING CHANNELS ("RE SHOWN ON PLAN) DETAIL TO BE USED FOR NEW MASONRY OPENING LESS THAN 41-8" WIDE (SEE 9/6401 FOR INTERIOR ELEV.) EXTERIOR EXIST. 8" CMU --- EXIST. MAS. WALL WALL STL, ANGLE LINTEL Note: Extend angle as required to support A I existing brick veneer v.i.f. NEW MASONRY OPENING (4) 1/4" �O TAPCONS AT ENDS (TYP.) L 6 x 4 x 3/8 (LLH), -- BEAR MIN. 8" EA. 51DE OF OPENING ON MAS, 4" GONG. 5LA8 ON —� GRADE w/ ro x ro — WIA x WIA WWF INTERIOR 1/4" # TAPCONS a 24" o.c. SAWCUT CMU AT JOINT _ 04 BAR x 18" LONG AT 24" O.G. 2i-011 / ii - 01—oil T.O. 5L c 'EXIST- LAB TOO BE SAWCUT BACK \............................\ \ I XX\\/1 EXIST. FDOTINC:/\\/\\ 6 W a 0 T Cr a O U w w a W of Z O CL W Z w w w ca U) Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z O — LUIql-191- alf M 2 I-- PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I DETAILS i JAMB DETAIL 311 = I'-0" m ELEVATION DETAIL N.T.S. MJW PROJECT #: 14022 A601 10/15/14 I 1 1 to PLUMBING LEGEND SANITARY SEWER (SAN) VENT (V)-------� COLD WATER (CW) — HOT WATER (HW) — — SHUT—OFF VALVE SITE POINT OF CONNECTION SEEDS Engineering, Inc. 27730 Santa Anita Blvd. p: (813) 902-2515 Wesley Chapel, FL 33544 f: ( 813) 902-2516 jmakar@seedseng.com Florida Certificate of Authorization No. 28278 ij Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 J I H l t Ur rLUKIUH REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 W J W 0 N a 0 U F- W 0 0 W — Ir Z PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 W Ir W CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY. FL 33525 PLUMBING FLOOR PLAN LU�l5INCT FLOOR FL74N 3/1&lj_I _01 N PROJECT #: 14022 P 10 1 I 1 2"V m �3"VTR � � I 13"V I� '�,2"V I 'I �� � � I r-2"V 2„ V I r I EXPOSED n j CONNECT TO EXISTING I I I I I \V 4" SANITARY SCS I I2 " V �000TG I 113"V I i " 2"V I I I 1 4" FCO LAV-HC I K3" O I2"V3" I12"V 2"DCSop I NOT TO 5CA1_E DISCONNECT SWITCH-�� BY ELECTRICAL SUBCONTRACTOR I VACUUM BREAKER: LTJI 36 WATTS OR EQUAL CHECKVALVE i GATE VALVE i COLD WATER--0Q-�-t i i i i i SERVICE DRAIN VALVE ASME T&P RELIEF VALVE: DWV COPPER FULL SIZE ROUTED TO DRAIN PAN WATER HEATER DRAIN: I COPPER DWV ROUTED TO ° FLOOR DRAIN WATER HEATER D ETA I L THERMAL EXPANSION TANK: AMTROL "THERM-X-TROL" ST-12 HEAT TRAP HOT WATER DIELECTRIC UNIONS SAFETY PAN: 24 GAGE GALVANIZED SHEET METAL, 1-1/2" DEEP, SOLDERED LIQUIDTIGHT PLUMBING GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES. THIS SHALL INCLUDE THE 2010 FLORIDA BUILDING CODE AND THE 2010 FLORIDA PLUMBING CODE, WITH LOCAL AMENDMENTS. 2. REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING. INSTALLATION TO INCLUDE ALL PLUMBING FOR COMPLETE SYSTEMS DEPICTED ON THE PLANS. 3. COORDINATE WITH OTHER TRADES TO PREVENT CONFLICTS WITH HVAC DUCTS, ELECTRICAL LIGHTING AND STRUCTURAL ELEMENTS. 4. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL FIXTURES SHOWN ON THE PLUMBING FIXTURE SCHEDULE. VERIFY MOUNTING HEIGHT AND CONNECTION SIZES OF ALL PLUMBING FIXTURES PRIOR TO INSTALLATION. 5. ALL WORK, BOTH MATERIAL AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM ACCEPTANCE BY THE OWNER. WATER PIPING 1. THE WATER PIPING SHALL BE TYPE "K" COPPER BELOW GRADE, WITH VINYL SLEEVE FOR ANTI -CORROSION, AND TYPE "L" ABOVE GROUND WITH WROUGHT COPPER FITTINGS (ASTM 816.22-89) AND SOLDER JOINTS. 2. THE WATER SERVICE TO THE BUILDING IS EXISTING TO REMAIN. 3. THE MAIN BACKFLOW PREVENTER IS EXISTING TO REMAIN. 4. THE SITE WATER METER IS EXISTING TO REMAIN. 5. SUPPORT ALL PIPING WITH PIPE HANGERS EQUAL TO GRINNEL. 6. PROVIDE EACH FIXTURE WITH A SHUT-OFF SUPPLY STOPS. EXPOSED STOPS AND SUPPLY PIPING SHALL BE CHROME PLATED, WITH CHROME ESCUTCHEON PLATE AND SET SCREW. STOPS SHALL BE 8" AFF FOR WATER CLOSETS AND 16" AFF FOR LAVATORIES. 7. PROVIDE UNIONS FOR ALL CONNECTIONS TO SERVICEABLE EQUIPMENT. UNIONS SHALL BE DIELECTRIC WHERE DISSIMILAR METALS ARE CONNECTED. 8. INSULATE ALL HOT WATER PIPING WITH j" ARMAFLEX OR J" FIBERGLASS EQUAL TO MANVILLE MICRO-LOK AP-T. VAPOR SEAL ALL BUTT JOINTS. 9. PROVIDE WATER HAMMER ARRESTORS, EQUAL TO JR SMITH 5000 SERIES, IN ACCORDANCE WITH PDI STANDARD WH-201. FIELD FABRICATED SHOCK ABSORBERS ARE NOT ACCEPTABLE. 10. PROVIDE VACUUM BREAKERS AS REQUIRED BY CODE. 11. STERILIZE ALL WATER PIPING IN ACCORDANCE WITH HEALTH DEPARTMENT REGULATIONS. 12. TEST ALL WATER PIPING AT 100 PSIG FOR SIX HOURS OR AS REQUIRED BY THE JURISDICTION. 13. PROVIDE SHUT OFF VALVES FOR ALL EXTERIOR HOSE BIBS AND WALL HYDRANTS. 14. PROVIDE SERVICE VALVES AT EACH BRANCH SUPPLY LINE, AS DEPICTED ON THE PLAN. ALL VALVES, CHECK STOPS, ETC. SHALL BE RATED FOR 125 LB SERVICE. VALVES SHALL BE BALL OR GATE TYPE, GLOBE VALVES ARE NOT ACCEPTABLE. VALVES SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION FOR SERVICING AND OPERATION. SANITARY, WASTE AND VENT PIPING 1. SANITARY WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC DWV (ASTM-2665) WITH SOLVENT WELDED JOINTS. 2. SLOPE OF SANITARY AND WASTE PIPING SHALL BE UNIFORM, WITH A MINIMUM OF j" PER FOOT FOR 2" AND A MINIMUM OF J" PER FOOT FOR LARGER PIPING. 3. EXPOSED WASTE DRAINS IN RESTROOMS SHALL BE CHROME PLATED BRASS TUBING WITH MATCHING CHROME ESCUTCHEON PLATE. 4. PROVIDE INTERIOR AND EXTERIOR CLEANOUTS AS REQUIRED BY CODE. 5. FURNISH 4 LB LEAD OR 8 OZ COPPER VENT FLASHING FOR INSTALLATION BY THE GENERAL CONTRACTOR FOR ALL VENTS THROUGH ROOF. VERIFY TYPE OF ROOFING PRIOR TO INSTALLATION. 6. TEST SANITARY, WASTE AND VENT PIPING USING A 10 FOOT WATER COLUMN FOR 2 HOURS OR AS REQUIRED BY THE JURISDICTION. BATHROOM FLOOR DRAIN TRAP PRIMER DETAIL PLUMBING FIXTURE SCHEDULE ROUGH -IN MARK FIXTURE, MODEL #, DESCRIPTION WASTE VENT CW HW WC-HC WATER CLOSET, HANDICAPPED 3" 2" 1/2" - KOHLER K-3519 WHITE ELONGATED, PRESSURE ASSISTED 1.0 GALLON FLUSH, TANK TYPE WATER CLOSET, OLSONITE #95 WHITE SEAT, CP STOP AND SUPPLY. LAV-HC LAVATORY, WALL HUNG, HANDICAPPED 1-1/2" 2„ 1/2" 1/2„ KOHLER K-2032 WITH K-11075-4 GOOSENECK FAUCET AND ADA COMPLIANT LEVER HANDLES, 1-1/4" CP P-TRAP, CP STOPS, SUPPLIES. WITH TRU-BRO INSULATION KIT. IMB ICE MAKER BOX 1/2" - RECESSED ICE MAKER BOX EQUIVALENT TO WATER TITE MODEL W9000 WITH WALL BOX FRAME AND COVER AND 1/2" SWEAT CONNECTION VALVE. EWC-SL ELECTRIC WATER COOLER, DUAL LEVEL, HANDICAPPED 1-1/2- 2- 1/2" - ELKAY EZSTL8C COOLER, STANDARD COLOR, 1-1/2" 20 GAUGE CP P-TRAP, LESS CO, STOP AND SUPPLIES. MOUNT LOWER BOWL NOZZLE AT 30" A.F.F FOR ADA. EWH-40 ELECTRIC WATER HEATER 3/4" 3/4" A.O. SMITH DEN-40 R-16 FOAM INSULATED, GLASS -LINED 40 GALLON TANK, THREE (3) YEAR WARRANTY WATER HEATER. 45" HIGH x 20" DIAMETER, 3.0 kW ® 208 VOLT, 1 PHASE ELECTRIC HEATER. U.L. LISTED AND ASHRAE 90.1-1999 APPROVED. WITH GRUNDFOS RECIRC PUMP AND AQUA-STAT/TIMER. LS LAB SINK 1-1/2„ 2„ 1/2„ 1/2„ ELKAY PSR1918-3 19"08 % 7" DEEP, 20 GAUGE TYPE 304 SELF -RIMMING SINK WITH LK2445 FAUCET AND LK99 DRAIN. 18 GAUGE P-TRAP, CP STOPS AND SUPPLIES. DCS DOUBLE COMPARTMENT SINK, 1-1/2„ 2„ 1/2„ 1/2„ ELKAY LRAD3322-60-3 33"x22"x6" DEEP, 18 GAUGE TYPE 304 SELF RIMMING DOUBLE COMPARTMENT SINK WITH LK4100 FAUCET, LK35 STRAINERS, CP P-TRAPS WITH CLEANOUTS, STOPS AND SUPPLIES. FD FLOOR DRAIN 3" 2" 1/2" - ZURN Z415-6B-P 6" FLOOR DRAIN WITH TRAP -PRIMER CONNECTION AND TYPE "B" STRAINER. TP TRAP PRIMER 1/2" - J.R. SMITH 2698 WATER SAVER TYPE, CP BRONZE PIPING AND ESCUTCHEON PLATES. ROUTE PRIMER PIPING IN WALL TO FLOOR DRAIN. WCO WALL CLEANOUT SEE - - ZURN Z1441 PLAN D.C.C.I. BODY WITH STAINLESS STEEL ACCESS COVER AND SECURING SCREW. FCO FLOOR CLEANOUT SEE - - ZURN Z1400 PLAN D.C.C.I. BODY ADJUSTABLE TO FINISHED FLOOR. COTG CLEANOUT TO GRADE SEE - ZURN Z1400-HD PLAN D.C.C.I. BODY ADJUSTABLE TO FINISHED GRADE WITH HEAVY DUTY TOP. SET IN 24"x24"x6" CONCRETE PAD. NOTES: 1. APROVED MANUFACTURERS OF FIXTURES ARE AMERICAN STANDARD, ELJER AND KOHLER. 2. APPROVED MANUFACTURERS OF DRAINS AND CLEANOUTS ARE J.R. SMITH, ANCON, WADE AND ZURN. 3. ALL SUPPLIES SHALL BE PROVIDED WITH CP BRASS ANGLE STOPS, EASTMAN, BRASSCRAFT OR EQUAL, PROVIDED AT ALL FIXTURES. 4. ALL EXPOSED TRAPS AND WASTE ARMS SHALL BE CP BRASS, MCGUIRE OR EQUAL. PLUMBING LEGEND SANITARY SEWER (SAN) VENT (V)-------5 COLD WATER (CW) - HOT WATER (HW) SHUT-OFF VALVE SITE POINT OF CONNECTION 0 W 0 U) Q 0 co Uj co 0 w Z 0 a 0 Z w a w m J J Q WiedFiCk Architecture, I nc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 ``X\111111/! \AN M A A- v No.54827 �:� p'•:c<ORIOP• STATE OF 0 a� ®d NALeN�'\ ®®� O N d' Q) co Q J -i ILL 4-a U) _l �- J LU �- �--� co = <Z LIJ PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 C:I IFNT- FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION I PLUMBING NOTES AND DETAILS SEEDS Engineering, Inc. 27730 Santa Anita Blvd. p: ( 813) 902-2515 Wesley Chapel, FL 33544 f: ( 813) 902-2516 jmakar@seedseng.com Florida Certificate of Authorization No. 28278 MJW PROJECT #: 14022 P201 HVAC GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES. THIS INCLUDES THE 2010 FLORIDA BUILDING CODE AND THE 2010 FLORIDA MECHANICAL CODE, WITH LOCAL AMENDMENTS, THE APPLICABLE NFPA CODES AND THE FLORIDA ENERGY CODE. 2. ALL ELECTRICAL EQUIPMENT SHALL BE UL CLASSIFIED OR LISTED. 3. DEFINITIONS: "FURNISH" SHALL MEAN TO PURCHASE AND LOCATE AN ITEM ON THE JOBSITE. "INSTALL" SHALL MEAN TO PHYSICALLY INSTALL AN ITEM AND CONNECT IT TO ALL REQUIRED SERVICES TO MAKE THE ITEM FULLY FUNCTIONAL. "PROVIDE" SHALL MEAN TO BOTH FURNISH AND INSTALL THE ITEM. 4. TEST AND BALANCE SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR ON APPROVED FORMS USED BY AABC OR NEBB. THE MECHANICAL CONTRACTOR SHALL HAVE ALL SYSTEMS FULLY INSTALLED AND OPERATIONAL WITH CLEAN FILTERS INSTALLED PRIOR TO TEST AND BALANCE. AIR CONDITIONING EQUIPMENT 1. THE AIR CONDITIONING EQUIPMENT SHALL BE STRAIGHT COOL, WITH ELECTRIC HEAT. 2. ALL EQUIPMENT SHALL MEET THE MINIMUM EER REQUIREMENTS OF THE FLORIDA ENERGY CODE. 3. TRANE IS THE BASIS OF DESIGN WITH AMERICAN STANDARD, CARRIER AND YORK AS APPROVED ALTERNATES. IF AN ALTERNATE IS SUBMITTED, THE CONTRACTOR SHALL MAKE ALL NECESSARY CHANGES TO THE ELECTRICAL, STRUCTURAL AND DUCTWORK TO ACCOMMODATE THE SUBSTITUTION. 4. SUBMITTALS SHALL BE REVIEWED BY THE ELECTRICAL SUBCONTRACTOR FOR IMPACT TO THE ELECTRICAL SYSTEMS, PRIOR TO ORDERING THE EQUIPMENT. 5. ALL AIR CONDITIONING EQUIPMENT SHALL INCLUDE A MINIMUM 1 YEAR UNIT WARRANTY AND AN EXTENDED 4 YEAR COMPRESSOR WARRANTY. 6. PROVIDE 1" CONDENSATE PIPING AS SHOWN ON THE PLAN AND DETAIL. THE CONTRACTOR SHALL EXTEND THE CONDENSATE PIPING TO THE EXTERIOR TO SPILL TO SITE STORM RETENTION. 7. THE AIR CONDITIONING UNITS SHALL BE OPERATED DURING CONSTRUCTION WITH THROW AWAY FILTERS. FILTERS SHALL BE CHANGED DURING CONSTRUCTION IF THEY BECOME RESTRICTIVE OF AIR FLOW FOR NORMAL OPERATION. PROVIDE NEW FILTERS JUST PRIOR TO TEST AND BALANCE. 8. UNITS SHALL BE CLEANED AND ALL SCRATCHES PAINTED OVER WITH FACTORY PAINT TO MATCH UNIT. ALL CONDENSER COILS SHALL BE COMBED OUT AND ALL PANELS AND SCREWS SHALL BE INSTALLED AT THE COMPLETION OF THE PROJECT. DUCTWORK 1. SUPPLY AND RETURN DUCT SHALL BE 1-1/2" DUCT BOARD, INSTALLED IN ACCORDANCE WITH SMACNA. SEE DETAIL FOR INSTALLATION AND HANGING INSTRUCTIONS. 2. OUTSIDE AIR AND EXHAUST DUCT WORK SHALL BE GALVANIZED SHEET METAL WITH ALL JOINTS SEALED WITH MASTIC. ROUND DUCT WORK SHALL BE "THERMOFIN" OR SINGLE WALL SHEET METAL. DUCTS DO NOT NEED TO BE INSULATED UNLESS REQUIRED BY LOCAL JURISDICTION. ALL DUCT SHALL BE CONSTRUCTED AND INSTALLED PER SMACNA. 3. ALL DUCT SIZES DEPICTED ARE CLEAR INSIDE DIMENSIONS. 4. SUPPLY AIR DUCT SHALL BE SIZED AT 0.10"/100 FT. EQUAL FRICTION AND RETURN DUCT SHALL BE SIZED AT 0.06"/100 FT. EQUAL FRICTION. 5. HOLD THE BOTTOM OF THE SUPPLY AIR DUCT A MAXIMUM OF 24" ABOVE LAY -IN CEILINGS TO ALLOW FOR ACCESS TO BALANCING DEVICES. 6. PROVIDE A FLEXIBLE CONNECTION FROM EACH AIR HANDLER AND FAN TO THE DUCT SYSTEM. 7. FLEXIBLE RUNOUTS TO THE DIFFUSERS ARE LIMITED TO A MAXIMUM OF 25 FEET. 8. PROVIDE ACCESS PANELS IN DUCTS FOR ACCESS TO VOLUME DAMPERS, FIRE DAMPERS, FIRE/SMOKE DAMPERS, DUCT MOUNTED SMOKE DETECTORS AND WHERE REQUIRED TO MAINTAIN EQUIPMENT. 9. ALL FLEXIBLE BRANCH CONNECTIONS SHALL HAVE A MANUAL VOLUME DAMPER INSTALLED AT THE MAIN TRUNK FOR BALANCING PURPOSES. CONTROLS 1. ALL TEMPERATURE CONTROLS SHALL BE 24 VOLT, AS PROVIDED BY THE MECHANICAL CONTRACTOR. 2. THERMOSTATS SHALL BE PROGRAMMABLE EQUAL TO HONEYWELL T8000 SERIES, OR BY UNIT MANUFACTURER, WITH STAGES OF COOLING AND HEATING TO MATCH THE UNITS SELECTED. MOUNT THERMOSTATS AT 5'0" AFF OR AS DIRECTED BY ARCHITECT/OWNER. 3. LOW VOLTAGE CONTROL WIRING SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR.THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT FOR ALL CONTROL WIRING AS COORDINATED WITH THE MECHANICAL CONTRACTOR. 4. LINE VOLTAGE (110 VOLT OR HIGHER) POWER AND CONDUIT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL DISCONNECT SWITCHES. DO NOT MOUNT DISCONNECT SWITCHES OVER NAMEPLATES OR SERVICE PANELS. 6. TEST AND BALANCE SHALL VERIFY THE OPERATION OF ALL CONTROLS AT THE COMPLETION OF THE PROJECT. 7. WHERE SMOKE DETECTORS ARE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR (NO FIRE ALARM SYSTEM), EACH SMOKE DETECTOR SHALL BE EQUIPPED WITH A REMOTE TEST STATION EQUIPPED WITH A VISUAL AND AUDIBLE ALARM TO BE LOCATED ADJACENT TO THE UNIT THERMOSTAT IN ACCORDANCE WITH NFPA 90. AIR DISTRIBUTION SCHEDULE DESIGNATION DESCRIPTION LEGEND SPECIFICATIONS EXAMPLE CD1-10-270 CEILING DIFFUSER CD1 PRICE ASCD SERIES, ALUMINUM, NECK SIZE NOTED 10" MODULAR CORE, LAY -IN MOUNTED, CFM NOTED 270 OFF-WHITE COLOR. RG1-24x24-300 RETURN GRILLE RG1 PRICE 610, ALUMINUM FACE SIZE NOTED 24x24" LOUVERED CORE, LAY -IN MOUNTED, CFM NOTED 300 OFF WHITE COLOR. RG2-16x16-200 RETURN GRILLE RG2 PRICE 610, ALUMINUM FACE SIZE NOTED 16x16" LOUVERED CORE, SURFACE MOUNTED, CFM NOTED 200 OFF WHITE COLOR. NOTES: 1. SIZES AND CFM SHOWN ON THE LEGEND ABOVE ARE FOR EXAMPLE ONLY. SEE PLAN FOR ACTUAL SIZES AND CFM VALUES USED ON THIS PROJECT. 2. LOCATE ALL AIR DISTRIBUTION PER THE ARCHITECTURAL REFLECTED CEILING PLAN 3. APPROVED MANUFACTURERS: PRICE, METALAIRE, KRUEGER, TITUS BUILDING AIR BALANCE OUTSIDE AIR INTO BUILDING EXHAUST AIR OUT OF BUILDING SOURCE CFM SOURCE CFM AHU-1 AHU-2 AHU-3 AHU-4 200 120 120 160 TEF-1 TEF-2 EXFILTRATION 50 50 400 TOTAL OUTSIDE AIR IN = 600 TOTAL EXHAUST AIR OUT = 500 BUILDING PRESSURIZATION = +100 OUTSIDE AIR CALCULATION SCHEDULE SPACE PEOPLE/SQUARE FEET REQUIRED OA PROVIDED CIA OFFICE 22 / 3018 SF 313 325 PHARMACY 2 / 399 SF 82 90 SALES 6 / 733 SF 133 140 STORAGE 0 / 613 SF 37 45 NOTE: 1. OUTSIDE AIR VOLUMES ARE BASED UPON ASHRAE STANDARD 62.1 SEEDS Engineering, Inc. 27730 Santa Anita Blvd. p: ( 813) 902-2515 Wesley Chapel, FL 33544 f: ( 813) 902-2516 jmakar@seedseng.com Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 �4N14 M A EN.Q SF., i No.54827 STATE OF 0 . R10 • � •NAI.EN�'� PRn.IF(-T AnnRF.q.q- Jb444 b I H AVI=. ZEPHYRHILLS, FL 33542 FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 MECHANICAL FLOOR PLAN FLOOR FLAN 3/1G It =1'-011 N(2) Florida Certificate of Authorization No. 28278 NI J VV PROJECT #: 14022 REFRIGERANT PIPING: NEOPRENE HANGER ISOLATORS II I I 1 II I I I II I I 1 II RETURN I I II A I R DUCT I I �� 1L_ Li I FLOAT SWITCH: LOCATED AT LOW SPOT IN DRAIN PAN, TO SHUT DOWN UNIT IF WATER GETS INTO THE DRAIN PAN. CONDENSATE DRAIN AND P-TRAP: 1" COPPER, 1/2" ARMAFLEX INSULATION DISCONNECT OR CIRCUIT BREAKER LOCATION: BY ELECTRICAL CONTRACTOR. SINGLE POINT SERVICE. I I- z LIJ I UNIT SHALL BE EQUIPPED WITH: ANTI -SHORT CYCLE TIMER CRANKCASE HEATER 10 YEAR COMPRESSOR/COIL WARRANTY HIGH PRESSURE SWITCH LOW PRESSURE SWITCH LIQUID LINE FILTER/DRIER SUPPLY AIR DUCT SECURE TO PAD WITH \ 16 GAGE STRAP AND SCREWS. (2) PER SIDE AUXILLARY DRAIN PAN: 22 GAUGE SHEET METAL SOLDERED WATER -TIGHT. 2" DEEP & 3" LARGER THAN UNIT. SUPPORT FROM DUCTWORK ONLY. AIR HANDLER MARK --- AHU-1 AHU-2,3 AHU-4 MANUFACTURER --- TRANE TRANE TRANE MODEL --- GAM5BOA60 GAM5BOA36 GAM513OA48 CAPACITY TONS 5.0 3.0 4.0 TOTAL COOLING MBH 60 36 48 SENSIBLE COOLING MBH 45 27 36 SUPPLY AIR CFM 1800 1200 1600 OUTSIDE AIR CFM 200 140 225 EXTERNAL STATIC PRESSURE IN H2O 0.6 0.6 0.6 FAN MOTOR HP/FLA 1 /7.6 1 /2/4. 1 3/4/6 ELECTRIC HEAT KW/VOLTS 7.68 7.68 7.68 FILTER TYPE --- - - - ELECTRICAL DATA V/PH/HZ 240/1 240/1 240/1 MCA AMPS 50 45 48 MOCP AMPS 50 45 50 LOCATION --- SEE PLAN SEE PLAN SEE PLAN WEIGHT LBS 170 142 166 HANGER SUPPORTS: ROUND 'SNAPLOCK" SHEET 8' O.C. = 0-35" DUCTS METAL FOR RUN -OUTS 6' O.C. = 36-59" DUCTS GREATER THAN 25', WITH ( 1", 22 GAUGE - TYPICAL) 2" WRAP INSULATION. AN APPROVED EQUAL IS "SPIRO-PIPE" SPIN -IN FITTING: WITH SCOOP AND DAMPER, EXCEPT IN GYP. BOARD CEILINGS, DAMPER IN NECK ----------- S S S N� AR EEC 1 TAPE AND MASTIC I I OUTER JACKET R �� \ I J (TYPICAL) - - I MINIMUM RADIUS EQUAL TO SADDLE: 22 GAUGE THE FLEX DUCT DIAMETER FLEXIBLE DUCT: MAXIMUM 25 FEET, DO NOT SAG OR KINK FIBERGLASS TAPE SUPPORTS TO PREVENT SAGS AND KINKS IN FLEX BAND CLAMP AND THREE SHEET METAL SCREWS THROUGH HELIX OF FLEXIBLE DUCT LINER (TYPICAL) 24" MAXIMUM VERTICAL DUCT RUN REINFORCEMENT: WRAP INSULATION ABOVE CEILING DIFFUSER: SET 0-24" = NOT REQUIRED THE CEILING DIFFUSERS THROW AS SHOWN ON PLANS 25"+ = REQUIRED AT 24" O.C. FIBERGLASS DUCT DETAIL 1. FIBERGLASS DUCTS SHALL BE FABRICATED & INSTALLED PER THE LATEST EDITION OF SMACNA AND THE 2010 FLORIDA ENERGY CODE WITH LOCAL AMENDMENTS. MATERIAL SHALL BE 1-1/2" 800 El BOARD, WITH A MINIMUM 6.0 "R" VALUE AND BE NFPA 90A APPROVED. 2. FABRICATION SHALL BE MACHINE CUT V-GROOVE OR SHIPLAP: BUTT JOINTS ARE NOT ACCEPTABLE. DUCT CLOSURE METHOD SHALL BE WITH GLASS FABRIC AND MASTIC USING "EPOLUX CADOPRENE 725", PRESSURE SENSITIVE TAPE, OR HEAT SEALABLE TAPE. ALL CLOSURE METHODS SHALL BE PER MANUFACTURERS INSTALLATION INSTRUCTIONS AND SHALL MEET THE REQUIREMENTS OF UL 181 FOR A CLASS 1 AIR DUCT SYSTEM. 3. SHEET METAL SLEEVES SHALL BE PROVIDED FOR; VOLUME DAMPERS, BRANCH TAKE -OFFS, REGISTER & GRILLE CONNECTIONS, RECTANGULAR DUCT CONNECTIONS, FIRE DAMPERS & DUCT HEATERS. 4. REINFORCEMENT CHANNELS, OR TEES, SHALL BE PROVIDED AS NOTED ABOVE & AT ALL ELBOWS OR AT ALL BRANCH CONNECTIONS, PER FIGURE 4.1. 5. HANGER SUPPORTS SHALL BE AS NOTED ABOVE (PER FIGURE 5-1D) FOR DUCTS UP TO 24", AND WITH TRAPEZE HANGERS (PER FIGURE 5-1B OR 5-1C) FOR DUCTS 25" AND ABOVE. 6. ELBOWS SHALL BE SQUARE NECK (SAME IN OUT DIMENSION) WITH 2" DOUBLE THICKNESS TURNING VANES. 7. OFFSETS SHALL NOT EXCEED 30' ANGLE, AND SHALL NOT REDUCE THE FREE AREA OF THE DUCT. 8. TRANSITIONS SHALL NOT EXCEED 1:3 RATIO (4" TRANSITION PER FOOT SINGLE SIDED TRANSITION, AND 8" PER FOOT DOUBLE SIDED TRANSITION). 9. RECTANGULAR BRANCH CONNECTIONS SHALL BE 45' ENTRY TYPE, WITH METAL SLEEVE & CLINCH LOCK CONNECTION. ENTRY LENGTH SHALL BE 25% OF BRANCH DUCT WIDTH. 10. ROUND DUCT CONNECTIONS SHALL BE WITH "METAL MANUFACTURING COMPANY" TL-FD-6 SPIN -IN FITTINGS, WITH SCOOP, DAMPER AND HANDLE. 11. FLEXIBLE ROUND DUCT SHALL INCLUDE: AN INNER POLYTHYLENE LINER, A SPRING HELIX, A 1-1/2" BLANKET INSULATION WITH MINIMUM 6.0 "R" VALUE AND AN ALUMINUM FOIL OUTER VAPOR BARRIER, AND BE UL-181 APPROVED. EQUIPMENT PAD B'. GENERAL CONTRACTOR DISCONNECT OR CIRCUIT BREAKER LOCATION: BY I ELECTRICAL CONTRACTOR. 4 rah' DO NOT MOUNT ON UNIT. ONTROL WIRING: APPROVED HIRE -TIES" EFRIGERANT PIPING: ERVICE VALVES: EXTERNAL D UNIT RATION ISOLATION PADS: 3/8" THICK, RIBBED, NEOPRENE CONDENSER UNIT MARK --- CU-1 CU-2,3 CU-4 MANUFACTURER --- TRANE TRANE TRANE MODEL --- 4TT8306OD1 4TTB3036E1 4TTB3048D1 CAPACITY TONS 5.0 3.0 4.0 CIRCUITS NO. 1 1 1 EFFICIENCY SEER/EER 13 13 13 COMPRESSOR NO/RLA 1/26.8 1/15.3 1/21.8 CONDENSING FAN NO/FLA 1 /0.93 1 /0.74 1 /1 .2 ELECTRICAL DATA V/PH/HZ 240/1 240/1 240/1 MCA AMPS 35 20 28 MOCP AMPS 60 35 50 LOCATION --- SEE PLAN SEE PLAN SEE PLAN WEIGHT LBS 226 159 203 NOTES --- - - - HANGER SUPPORTS: 1/4" THREADED ROD & NEOPRENE ISOLATORS, DO NOT SUPPORT FROM CEILING DISCONNECT SWITCH: FURNISHED BY THE { MECHANICAL SUBCONTRACTOR i i VARIABLE SPEED i CONTROLLER L a 1 CEILING 11 Z� SEAL ALL SHEET METAL DUCT WITH MASTIC ONLY (NO TAPE) - BACKDRAFT DAMPER: CLEAR OF SCREWS EXHAUST GRILLE: BY FAN MANUFACTURER CEILING FAN DETAIL MARK - TEF-1,2 MANUFACTURER - GREENHECK MODEL - SP-B70 SERVICE - SEE PLAN AIR QUANTITY CFM 50 EXTERNAL STATIC PRESSURE IN H2O 0.3 FAN TYPE - CENTRIFUGAL MAXIMUM FAN SPEED RPM 643 DRIVE - DIRECT MOTOR HP(W) 45 W ELECTRICAL V/PH/HZ 115/1 CONTROLS - WITH LIGHTS SONES - 2.0 WEIGHT LBS. 9 NOTES - - MOUNTING ANGLES: 1-1/2" x 1-1/2" WRAP INSULATION Al x 16 GA, FASTENED TO SLEEVE (ONLY) • WITH #10 SHEET BREAKAWAY CONNECTION: ° METAL SCREWS ON PER FIGURE, SMACNA r 8" CENTERS. "FIRE DAMPER & HEAT DO NOT FASTEN STOP GUIDE" 1981 TO AT CORNERS. EITHER SLEEVE (TYPE A) OR TO DAMPER I MAX 1/2" (FOR TYPE B) I CLEARANCE FIRE DAMPER. CLOSURE SIZE EQUAL TO I SPRING 1/4" LESS THAN DUCT SIZE & FASTENED TO I I SLEEVE WITH DUCT: SIZE #8 SHEET METAL PER PLAN SCREWS ON 8" CENTERS .•. SLEEVE: SIZE & ;. FIRE -RATED LID: GAUGE TO MATCH OPENING BY GENERAL DUCT. CONTRACTOR. OPENING SIZE 0-12" DUCT = 26 GA EQUAL TO DUCT SIZE PLUS 13-30" DUCT = 24 GA MAX 6" � 1/4" PER FOOT OF DUCT 31-54" DUCT = 22 GA SLEEVE SIZE, TO ALLOW CLEARANCE 55-84" DUCT = 20 GA EXTENSION OF OF 1/8" PER FOOT OF DUCT SIZE. HORIZONTAL FIRE DAMPER DETAIL 1. ALL FIRE DAMPERS SHALL BE UL 555 APPROVED. 2. FIRE DAMPERS WITH INTEGRAL SLEEVE AND FACTORY MOUNTING ANGLES ARE ACCEPTABLE (RUSKIN OR EQUAL). 3. INSTALLATION SHALL COMPLY WITH UL APPROVED INSTALLATION INSTRUCTIONS. 4. HORIZONTAL DAMPERS SHALL HAVE A STAINLESS STEEL CLOSURE SPRING FOR OPERATION OF THE DAMPER. 5. PROVIDE AN ACCESS DOOR, MINIMUM 10"00", ADJACENT TO THE FUSIBLE LINK OF EACH DAMPER. DOOR SHALL BE FACTORY FABRICATED, WITH 24 GA FRAME & DOOR, FIBERGLASS INSULATION, NEOPRENE GASKETING, & CAM -LOCK FASTENERS. 6. LOCATION OF FIRE DAMPERS SHALL BE AS SHOWN ON THE PLAN, WITH THE STANDARD SYMBOL 1- POINTING TO THE LOCATION OF A TYPE "A" FIRE DAMPER, AND THE STANDARD SYMBOL (B)IO POINTING TO THE LOCATION OF A TYPE "B" FIRE DAMPER. BIRDSCREEN FACTORY CURB: SEE DETAIL ROOF COORDINATE WITH OTHER TRADES TO AVOID PIPING & CONDUIT INTERFERENCES WITH ROOF INTAKE DUCTWORK ROOF INTAKE DETAIL REMOVABLE TOP: SPUN ALUMINUM ROOF INTAKE DUCTWORK: NO INSULATION, MASTIC SEAL �- REFRIGERATION PIPING PIPE CLAMPS: "HYDRO ZORB" OR "SUPER -STRUT", WITH SIZE TO MATCH ELECTRICAL CONDUIT. SUPPORT CHANNEL: "HYDRO ZORB" OR "SUPER -STRUT" REFRIGERANT PIPING DETAIL 1. ALL REFRIGERANT PIPING SHALL BE HARD COPPER, ACR TYPE "L", WITH LONG RADIUS ELBOWS AND WROUGHT FITTINGS. 2. TRAPS SHALL BE SINGLE PIECE, WROUGHT COPPER. 3. INSULATE SUCTION LINES FULL LENGTH WITH "ARMAFLEX" INSULATION. THICKNESS SHALL BE 1/2" UP THROUGH 7/8" SUCTION LINE SIZE, WITH 3/4" THICKNESS FOR 1-1/8" SUCTION LINES & ABOVE ALL INSULATION SHALL BE ASTM E84 APPROVED (FLAME SPREAD OF 25, SMOKE DENSITY OF 50). 4. INSULATION SHALL NOT BE SPLIT DURING INSTALLATION. 5. ROUTING OF ALL REFRIGERANT PIPING SHALL BE "SQUARE WITH" BUILDING LINES. HORIZONTAL PIPING SHALL BE SLOPED AT THE RATE OF (1) INCH FOR EACH (10) FEET, TOWARD THE COMPRESSOR. 6. SUPPORT OF THE REFRIGERANT PIPING AT THE COMPRESSORS, CONDENSERS, AND AIR HANDLING UNITS SHALL BE AS SHOWN ABOVE. 7. SUPPORT OF THE REFRIGERANT PIPING, IN CEILING PLENUMS, SHALL BE WITH STRAP HANGERS, SHEET METAL "SADDLES", WITH 3/4" INSULATION TO ELIMINATE ANY METAL -TO -METAL CONTACT. 8. BRAZE ALL REFRIGERANT PIPING WITH A FLOW OF DRY NITROGEN DURING THE BRAZING OPERATIONS. 9. SOLDER SHALL BE 15% SILVER "SIL-FOS" OR EQUAL. 10. CHANGE FILTER -DRIER CORES AFTER 30 DAYS OF OPERATION. SAVE CORES FOR INSPECTION BY TEST & BALNCE, OR BY OWNERS REPRESENTATIVE INSPECTION. SEEDS Engineering, Inc. 27730 Santa Anita Blvd. p: (813) 902-2515 Wesley Chapel, FL 33544 f: (813) 902-2516 jmakar@seedseng.com Florida Certificate of Authorization No. 28278 Wiedrick Architecture, I nc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 51 A I E OF I-LUKIUA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 No.54827 r STATE OF o,� '�<oRioP •�w� o: F• � e ALENG t'KVJt_u I HUUKtJJ: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 MECHANICAL NOTES AND DETAILS PROJECT #: 14022 U DIVISION 16000 ELECTRICAL SPECIFICATIONS SECTION 16010 GENERAL PROVISIONS PART1-GENERAL 1.01 WORK INCLUDED A. Furnish all labor, materials, and equipment as required by the plans and specifications to provide a complete and operable electrical system. This specification describes the types of materials, methods, and management to be utilized. This includes the work listed in this division as well as equipment furnished under other divisions not specifically mentioned herein. B. Guarantee all materials and labor for a period of (1) year from date of substantial completion. Pass on any additional manufacturer warranties to the owner. C. Contractor shall coordinate with electric and telephone utilities prior to bid and furnish both with their required sets of plans within 10 days of being awarded project. Obtain pdfs of plans from GC to plot and send to the utility companies. 1.02 CODES AND STANDARDS A. All equipment, materials, and methods of design and installation are to comply with the National Electrical Code (NEC), the Occupational Safety and Health Act (OSHA), and the requirements of applicable local codes. Codes and standards of the following organizations may be referred to in this section and shall be considered as the minimum acceptable. A reference herein to any portion of the standard or code is not to be considered as negating any other portion of the standard or code. 1. National Electrical Code (NEC), 2008 ed. 2. National Electric Manufacturers Association (NEMA) 3. Underwriters Laboratories, Inc. (UL) 4. Florida Building Code (FBC), 2010 ed. 5. Florida Fire Prevention Code (FFPC), 2010 ed. 1.03 EQUIPMENT, MATERIAL AND WORKMANSHIP A. All equipment and material shall be new unless allowed below, free from defects, of current manufacture, and listed by Underwriters Laboratories, Inc., (UL) where UL requirements apply. All materials are to be products of reputable and experienced manufacturers. B. Provide protection for materials and equipment against loss or damage throughout the contract. Provide protection from the effect of weather prior to installation, store items to be installed in indoor weather protected location. C. Following installation, protect materials and equipment from corrosion, physical damage and effects of moisture on insulation. D. Do not cut or notch any structural member or building surface without specific approval of the Structural Engineer. E. All work will be performed by accomplished, qualified and experienced personnel working under continuous competent supervision. F. Contractor shall restore fire ratings of all rated assemblies penetrated with the appropriate assembly: W-L-1049, W-L-3214, W-L-4008, C-AJ-1353, C-AJ-1354, C-AJ-1080, or equivalent suitable with penetrant and wall/floor assembly. 1.04 PERMITS A. Obtain and pay for all permits and inspections pertinent to the electrical installation. 1.05 SITE INSPECTION A. Prior to submitting a bid, visit the project site and ascertain conditions affecting the proposed work and all existing electrical facilities. B. Furnish all labor associated with accompanying Engineer during observations of construction. 1.06 TEMPORARY INSTALLATION A. Provide all temporary lighting and 120V/20A power reachable with a 100ft extension cord for use by trades. B. Temporary installation shall conform to the requirements of the NEC, OSHA, and the State and local governing bodies. C. Pay all cost for temporary power services and power usage charges until project final acceptance by owner. 1.07 SHOP DRAWINGS A. Submit 6 copies of all project submittal data and shop drawings. B. Submit complete shop drawings for review prior to purchase of the following: 1. Light fixtures. 2. Wiring devices. 3. Panelboards, switchboards, transformers, safety switches, and fuses. 4. Fire alarm system. C. Contractor shall review shop drawings and submittals of every trade where an electrical connection is required and report any variances from electrical characteristics noted on the electrical drawings to the Engineer before proceeding with rough -in work. 1.08 RECORD DRAWINGS A. Maintain a neatly marked set of record drawings showing installation location, and/or routing of conduits, depth of buried cables, pull boxes, junction boxes, outlets, and a single -line diagram of the building electrical distribution system and floor plans indicating location and area served for all distribution. After final inspection, within 30 days after the date of system acceptance, transfer all record information to the Owner as required in the contract. B. If the contractor elects not to utilize circuitry as designated on plans and in schedules, contractor shall provide as -built markups of plans and schedules to engineer. C. An operating manual and maintenance manual shall be provided to the building owner. The manuals shall include, at a minimum, the following: 1. Submittal data stating equipment rating and selected options for each piece of equipment requiring maintenance. 2. Operation manuals and maintenance manuals for each piece of equipment requiring maintenance. Required routine maintenance actions shall be clearly identified. 3. Names and addresses of at least one qualified service agency. PART 2 - EXECUTION 2.01 INSTALLATION A. The electrical plans show general arrangements and locations for equipment conduit, outlets, etc. Unless detailed or dimensioned, exact locations of conduit, routing of cables and placement of equipment will be governed by structural conditions, physical interference, owner equipment, and locations of electrical termination on equipment. Examine architectural, structural, and mechanical plans and shop drawings for the various equipment in order to determine exact routing and placement of all raceways, cables, and equipment, to assure a workable installation in accordance with NEC. Such coordination shall be anticipated during bid. B. Where plans and specifications or schedules are in conflict, contractor shall assume the most stringent requirements apply and submit an RFI prior to submitting bid. C. Any product substitutions from specified make & model numbers shall be qualified in bid in writing with explanation of reason for substitution and cost savings associated with substitution. D. Contractor shall obtain Fire Protection drawings where ESFR fire protection is installed and maintain 12" clearance (24" if FM Global has jurisdiction) from all ESFR sprinkler heads with light fixtures, raceways, and any other electrical component. ***END OF SECTION*** SECTION 16070 ELECTRICAL CONNECTIONS FOR EQUIPMENT PART1-GENERAL 1.01 WORK INCLUDED A. Provide all labor, materials and equipment as required furnishing connections to all electrical equipment, lights, etc. PART 2 - PRODUCTS 2.01 GENERAL A. See Section 16111, Conduit Raceways; Section 16140 Wiring Devices; and Section 16120 Wire and Cables for additional requirements. Provide final connections for equipment consistent with the following: 1. Permanently installed fixed equipment - flexible seal-tite conduit from branch circuit terminal equipment, or raceway; to equipment, control cabinet, terminal junction box, or wiring terminals. Totally enclose all wiring in raceway. 2. Movable and/or portable equipment - wiring device, cord cap, and multi -conductor cord suitable for the equipment and in accordance with NEC requirements (Article 400). 3. Other methods as required by the National Electrical Code and/or as required by special equipment or field conditions. PART 3 - EXECUTION 3.01 INSTALLATION OF ELECTRICAL CONNECTIONS A. Make electrical connections in accordance with connector manufacturer's written instructions and with recognized industry practices, and complying with requirements of NEC and NECA's "Standard of Installation" to ensure that products fulfill requirements. B. Connect electrical power supply conductors to equipment conductors in accordance with equipment manufacturer's written instructions and wiring diagrams. C. Verify all electrical loads (voltage, phase, full load amperes, number and point of connections, minimum circuit ampacity, etc.) for equipment furnished under other Sections of this specification, by reviewing respective shop drawings furnished under each section. Report any variances from electrical characteristics noted on the electrical drawings to the Engineer before proceeding with rough -in work. D. Obtain and review the equipment shop drawings to determine particular final connection requirements before rough in begins for each equipment item. E. Contractor shall pay particular attention to lug arrangements in project submittal data, as well as in the field when equipment arrives, with respect to specified conductors for every piece of equipment and report any variances from electrical characteristics noted on the electrical drawings to the Engineer before proceeding with rough -in work. ***END OF SECTION*** SECTION 16111 CONDUIT RACEWAYS PART 1- GENERAL 1.01 WORK INCLUDED A. Furnish all labor, materials and equipment as required to install all flexible or rigid conduit, couplings, supports and nonmetallic ducts, as shown on the Plans. PART 2 - PRODUCTS 2.01 MATERIALS A. GENERAL: Provide conduit, and fittings of types, grades, sizes, and weights (wall thicknesses) as indicated; with minimum trade size of 1/2" above grade and 3/4" below grade. B. Electrical Metallic Tubing (EMT) with die cast or steel set -screw fitting for dry and damp locations, compression for wet locations. C. RIGID METAL CONDUIT (RMC) with threaded fittings and UL 6 listing. D. RIGID NON-METALLIC CONDUIT (RNC): Schedule 40, with matching glue -on socket fittings. E. FLEXIBLE METALLIC CONDUIT (FMC): Galvanized interlocked steel strip with positive locking cadmium plated steel or malleable iron fittings. F. LIQUID -TIGHT FLEXIBLE METAL CONDUIT (LT): Provide liquid -tight, flexible metal conduit; constructed of single strip, flexible continuous, interlocked, and double -wrapped steel; galvanized inside and outside; coated with liquid -tight jacket of flexible polyvinyl chloride (PVC) with positive locking cadmium plated steel or malleable iron fittings and compression type steel ferrule and neoprene gasket sealing rings. G. EXPANSION FITTINGS: OZ Type AX, or equivalent to suit application. 2.02 SCHEDULE OF LOCATIONS A. RMC or Schedule 80 PVC in all areas subject to physical damage to an elevation of 48" AFF/AFG. B. EMT for all above grade areas in the building unless noted otherwise. C. RNC for all areas below grade. D. LT for all exposed locations within coolers and freezers. E. Make connections to motors and equipment with FMC and LT as environmental conditions dictate. PART 3 - EXECUTION 3.01 INSTALLATION A. Install conduit concealed in all areas where possible. B. Coordinate installation of conduit in masonry work. C. Plug ends of conduits to prevent entry of dirt or moisture. Provide non -shrinking electrical putty to seal conduits which emerge from grade after conductors are installed. D. Route all exposed conduits parallel or perpendicular to building lines. E. Do not exceed number of bends in conduit beyond that allowed by the NEC. F. PVC conduit runs less than 50 ft shall incorporate Schedule 80 elbows, over 50 ft use RMC coated with bitumastic. Prior to backfill, take digital photographs. G. Keep conduits at least 12" away from gas lines and hot water pipes, and in no case permit conductors to reach higher than rated temperatures. H. Fasten raceways securely in place. Firmly fasten conduit within three feet of each outlet, junction box, cabinet, or fitting. Support metallic conduit in accordance with the NEC. Use "bolt -on" raceway fasteners designed for the purpose in exposed and wet areas, "snap -on" black metal "Caddy" clips in metal stud walls and above ceilings. All fasteners, straps, clips, etc. shall be UL listed for their use. Where conduit is surface mounted in kitchen, secure with stand-off style straps which allow all sides of the conduit to be cleaned. I. Weatherproof any penetration through exterior of building including slab on grade. J. Provide pull boxes as dictated by wire pulling requirements. Unless shown otherwise, face into secondary or unfinished rooms. K. All raceways shall be kept at least 1-1/2" away from metal roof decking. L. All empty raceways used for structured cabling shall be terminated with connectors and bushings. M. Make watertight roof penetrations at equipment served. Conduits shall not be run horizontally exposed on top of roofs. N. Provide suitable protection of conduits during construction to prevent debris from entering while conduits are not terminated. O. Do not install raceways within 12" horizontally of ESFR sprinkler heads (24" if FM Global has jurisdiction). ***END OF SECTION*** SECTION 16120 BUILDING WIRE AND CABLE PART 1- GENERAL 1.01 WORK INCLUDED A. Furnish all labor, materials, and equipment as required to install all wires and cables as shown on the Plans, and as required to connect all electrical services and equipment. PART 2 - PRODUCTS 2.01 MATERIALS A. All wiring shall be copper unless specifically noted otherwise on plans. Where type XHHW-2 aluminum conductors are permitted per the plans, conductor terminations shall be made with compression pigtail adapters (ILSCO Type ACM or ACO) with anti -oxidant applied to exposed conductor. Owner is advised to refer to NFPA 70B for periodic inspection recommendations. B. Minimum size conductors and insulation types: 1. Branch circuits and feeders, # 12 AWG THHN/THWN. 2. Service entrance, XHI-IW or THWN. 3. Control circuits, # 14 AWG THHN/THWN. C. MC Cable may be used in lieu of conduit and wire where installed in accordance with all of the following conditions. 1. Concealed and only where approved by owner. 2. Per requirements of the NEC and local codes. 3. Branch circuits 30 amps and below. 4. Where installed after the first junction box from a panel, i.e. do not connect MC cable to panelboards. PART 3 - EXECUTION 3.01 INSTALLATION A. Color coding shall be as follows: Voltage Phase A Phase B Phase C Neutral 120/240 Black Orange Blue White B. Provide a green grounding conductor in all raceways except service entrance. Provide a green with yellow stripe conductor in raceways with isolated ground conductors specified on plans. C. Provide conductors with identification tags as manufactured by Brady or approved equal. D. Install wires and cables continuous without splices from source of supply to distribution equipment and from source of supply to motors, lighting, or power outlets. Do not use pull boxes for making splices. Do not install splices in conduits or trench. E. Support vertically installed conductors at intervals not to exceed those allowed by the NEC. Do not splice vertically installed conductors. F. Remove any existing wiring (line voltage and low voltage) which is abandoned in place or will become obsolete due to construction. G. Any feeder lengths described in Voltage Drop or Fault Current Study tables are not to be relied upon for bidding or construction. Contractor is advised to review specification 16010, 2.01, A for coordination with other trades which may affect feeder installation routing and lengths. H. Prior to energizing, check service lateral and feeders for electrical continuity and clear of short-circuits. Check with "Megger" tester for phase -to -phase, phase -to -neutral, and phase -to -ground insulation resistance levels to insure system insulation levels are in accordance with manufacturer's recommendations. Use 500 volt tester for 208 volt and 240 volt applications;1000 volt tester for 480 volt applications. If resistance levels are low, take corrective measures as necessary including but not limited to replacement of all materials as required. ***END OF SECTION*** SECTION 16130 PULL AND JUNCTION BOXES PART 1- GENERAL 1.01 DESCRIPTION A. Construct junction or pull boxes less than 100 cubic inches as "standard outlet boxes". B. Construct junction or pull boxes greater than 100 cubic inches as "cabinets". C. Provide all covers of same gauge metal and include screws. PART 2 - PRODUCTS 2.01 STANDARD OUTLET BOXES A. Make of material resistant to corrosion or suitably protected, both internally and externally by galvanizing. B. Boxes installed in damp or wet locations shall be U.L. approved for the purpose. C. Metal boxes to meet NEC construction specifications. D. Boxes exposed or surface mounted shall be die-cast or permanent- mold cast aluminum body with threaded external hub and cast cover. E. Provide in -ground junction box, Quazite #PG1118BA12 /PG1118HH00 or equivalent for in ground applications. Top flush with finished grade. 2.02 CABINETS A. 14 gauge sheet steel with corrosion resistant finish. B. Ample space for wires, connections and equipment. C. Cabinet fronts: Sheet steel panels with hinged door and locking provisions. D. Flush cabinets: Cover shall be approximately 3/4" larger than cabinet on all sides, set with front firmly against the finished wall surface. E. Telephone cabinets: Size and depths as noted on Drawings, with fire -retardant wood backboards. PART 3 - EXECUTION 3.01 INSTALLATION A. Install junction boxes so that covers are readily accessible after the completion of the installation. B. Mount rigidly in place with front of box level and plumb. C. Secure flush covers with corrosion resistant screws or bolts. D. Provide each pull box with sufficient clamps to which cables shall be secured in neat and orderly fashion I ? T ` 1 d K- permitting ready identification. E. Mount pull boxes connected to concealed conduits with covers flush with the finished wall. fi Architecture, 1 I1C. F. Neatly write each "panel - circuit" contained in each junction box on the cover with a permanent marker. ***END OF SECTION*** WIEDRICK ARCHITECTURE INC. SECTION 16140 ` " AA26001799 WIRING DEVICES 2020 HEIDELBERG AVE. PART 1-GENERAL = DUNEDIN, FLORIDA, 34698 1.01 WORK INCLUDED 727.736.8627 A. The work under this section includes wall switches, receptacles, occupancy sensors, wall dimmers, device plates and box covers, poke -through service fittings, access floor boxes, photocells and time clocks. y STATE OF FLORIDA PART 2-PRODUCTS PROFESSIONAL ENGINEER: MATTHEW OTTO 2.01 DESCRIPTION PE 58722 A. WALL SWITCHES: 20-amp,120/277V commercial grade. Single pole (White): Leviton CS120-2W. 3-way (White): Leviton CS320-2W. 4-way (White): Leviton CS420-2W. 2-pole (White): Leviton CS220-2W. B. RECEPTACLES (multiple on a branch circuit): 15-amp, 120V commercial grade. Duplex (White): Leviton w Z CR15-W. Duplex Tamper Resistant (White): Leviton CR15S-GW. �j Z C. RECEPTACLES (single duplex or simplex on a branch circuit): 20-amp,120V commercial grade. Duplex�-•� O (White): Leviton CR20-W. Simplex (White): Leviton 5801-W.�-{ H D. GFCI RECEPTACLES: 20-amp,120V commercial grade. Duplex (White): Leviton 7899-W. Receptacles w a U') ,n . serving vending machines and drinking fountains shall be GFCI type. H x E. GFCI RECEPTACLES: 20-amp,120V commercial grade, weather resistant. Duplex (White): Leviton o H o rn 00 W7899-W for all outdoor, cooler, freezer, and any other damp or wet locations. O F. OCCUPANCY SENSORS (wall mounted): Dual technology, maximum load of 80OW at 120V or 120OW at p 277V, Watt Stopper DW-100-W. Adjust for 15 minute time delay and appropriate sensitivity.CZ G. OCCUPANCY SENSORS (ceiling mounted 10' AFF or less): Maximum load of 80OW at 120V or 120OW at O w H v w E U 277V, Watt Stopper DT-355-W (DT-300-W with BZ150 power pack for low voltage applications). Adjust for U w 15 minute time delay and appropriate sensitivity. I w H. TIMER SWITCH: Digital adjustable with a range of 5 minutes to 12 hours. Maximum load of 80OW at 120V r U or 1200W at 277V, Watt Stopper TS-400. I. PHOTOCELL: Weatherproof, adjustable. Intermatic K4100 series. o Z Q J. TIME CLOCK: Single or multi -circuit as indicated on the plans. Intermatic ET90000 series. c IIPtPIp � w `ttttfh PART 3 - EXECUTION * P ........••.. ° ®= 3.01 GENERAL No. 58722 A. All devices are to be installed in 4" square boxes, except when installed in masonry. • ,bi '• STATE OF :• B. Cover plates in commercial kitchens shall be type 302 stainless steel. All other cover plates shall be smooth®'•.•.• F P C 4U� -Z'o ae white nylon unless otherwise specified herein. �f°c`�s ., 0RkO...��N, C. Cover plates for receptacles installed in damp or wet locations shall be weatherproof while -in -use. O '��SRO N AL D. Cover plates for light switches in exterior, cooler, and freezer applications shall be equivalent to Carlon E98TSCN-CAR weatherproof cover. E. Note mounting heights indicated by the symbology and notes on the plans. F. All devices shall have a bonding pigtail conductor from grounding terminal to the metal box system (except IG). Self -grounding receptacles using mounting screws as bonding means are not approved. G. Except as otherwise indicated on the Drawings, mount devices flush, with long dimension vertical, and grounding pin on receptacles on bottom. Group adjacent switches and receptacles under a single, multi -gang wall plate. Where communications outlets are shown adjacent to power receptacles, both shall be installed at same elevation. O N It ***END OF SECTION*** CLO SECTION 16170 Q J LL GROUNDING AND BONDING = Lo J PART1-GENERAL J 1.01 WORK INCLUDED � _ A. Grounding electrodes and conductors, equipment grounding conductors and bonding. i - UJI PART 2 - PRODUCTS o a N 2.01 ROD ELECTRODE Q 0 A. Material: Copper -clad steel. ° B. Diameter: 3/4" minimum, w C. Length: l0' minimum. Rod shall be driven at least 9'-6" deep. J UJ PROJECT ADDRESS: D. Provide the number of rods required to obtain proper ground resistance. 038444 5TH AVE. ZEPHYRHILLS, FL 33542 2.02 MECHANICAL CONNECTORS UJ UJ A. The mechanical connector bodies shall be manufactured from high strength, high conductivity cast copper alloy material. Bolts, nuts, washers and lock washers shall be made of Silicon Bronze and supplied as a part of the connector body and shall be of the two bolt type. B. Split bolt connector types are NOT allowed. CLIENT: C. The connectors shall meet or exceed UL 467 and be clearly marked with the catalog number, conductor size 0 FLORIDA PHARMACY and manufacturer. LU SOLUTIONS, INC. 0 13933 17TH ST. SUITE 300 2.03 COMPRESSION CONNECTORS Z DADE CITY, FL 33525 A. The compression connectors shall be manufactured from pure wrought copper. The conductivity of this Z 0 UJ material shall be no less than 99% by IACS standards. ; DATE DESCRIPTION B. The installation of the connectors shall be made with a compression, tool and die system, as recommended ° by the manufacturer of the connectors. 0 C. The connectors shall be clearly marked with the manufacturer, catalog number, conductor size and the LD required compression tool settings.LU o D. Each connector shall be factory filled with an oxide -inhibiting compound. 0 2.04 EXOTHERMIC CONNECTIONS Z A. WIRE z LU 1. Material: Stranded copper (aluminum not permitted). 2. Grounding Electrode Conductor: Size as shown on drawings, specifications or as required by NFPA o SPECIFICATIONS 70, whichever is larger. UJ o MDO PROJECT #: 14-87 Z Z E001 10/15/14 U PART 3 EXECUTION 3.01 GENERAL A. Install Products in accordance with manufacturer's instructions. B. Mechanical connections shall be accessible for inspection and checking. No insulation shall be installed over mechanical ground connections. C. Attach grounds permanently before permanent building service is energized. D. Install rod electrodes at "non -trip -hazard" locations indicated or as required by Code, whichever requires the most rods. Install additional rod electrodes as required to achieve specified resistance to ground. E. Provide bonding to meet NEC Requirements, including but not limited to bonding between telephone, television, and security systems. F. Coordinate with general contractor to insure at least (2) column anchor bolts are tied to footing steel rebar at column nearest electrical service using the usual steel tie wires. 3.02 FIELD QUALITY CONTROL A. Inspect grounding and bonding system conductors and connections for tightness and proper installation. B. Measure ground resistance from system grounding electrode connection at service entrance (neutral -ground bond removed) to earth ground reference point using suitable ground testing equipment. Resistance shall not exceed 25 ohms. ***END OF SECTION*** SECTION 16426 DISTRIBUTION EQUIPMENT PART 1 - GENERAL 1.01 WORK INCLUDED A. Standard and custom products equivalent to Square D, NQOD, NF, I -Line panelboards, and QMB switchboards, as well as safety switches, contactors, and starters. Cutler Hammer, Siemens, and GE are acceptable manufacturers. PART 2 - PRODUCTS 2.01 MATERIALS A. All distribution gear shall be fully bussed and fingered for all pole positions numbered on schedules. B. All distribution gear shall have a ground bus. C. For 4-wire systems, the neutral bus shall be the equivalent ampacity as the phase bus bars. D. Provide mechanically fastened permanent plastic nametag with 1/4"H letters indicating name of each switchboard, panelboard, and transformer as well as a permanent plastic nametag indicating each load fed for each switchboard. E. All panelboards and switchboards shall use bolt -on circuit breaker overcurrent devices. F. Provide circuit breakers UL listed as Type HACR for air conditioning equipment branch circuits. G. Do not use tandem circuit breakers. H. Safety switches used for service disconnecting means shall be Heavy Duty,100,000 AIC minimum. All others may be General Duty. I. Provide Class L fuses for individual motors, 50 hp and larger; Class J for service mains including tenant meter disconnects downstream of mains; Class RK5 fuses for all other applications. J. Refer to panel schedules for ampacities, voltage, phase, NEMA rating, mounting configuration, AIC rating, and accessories. K. Lighting contactors shall have 30 amp rated contacts, minimum. L. Provide a typewritten panel directory for each panelboard or loadcenter with sufficient detail to distinguish each circuit from all others within the panelboard or loadcenter. M. Sharing a neutral is permitted for up to three circuits, one per phase, of the same amp rating for 208Y/120V branch circuits on non -dimmed circuits. Where a shared neutral conductor is used for multiple branch circuits, contractor shall either group circuits together in panel and provide a manufacturer furnished and listed handle -tie to simultaneously trip all of the circuits sharing the neutral or provide multi -pole circuit breakers. Plans may not depict shared neutrals, but they are allowed in accordance with the above specification. N. All circuit breakers used for service disconnecting means,1,200 amps and larger, shall have electronic trip units equivalent to Square D MicroLogic 5.OH (6.OH where GFI is specified). Such breakers shall be accompanied with a factory installed phase failure relay, Taylor PND-###-T3 or equivalent. PART 3 - EXECUTION 3.01 INSTALLATION A. Install panelboards plumb with wall finishes with height 6-6" AFF to top. B. Provide filler plates for unused spaces in panelboards. C. Inspect for physical damage, proper alignment, anchorage, and grounding. Check proper installation and tightness of connections. D. Rigidly mount disconnects and starters adjacent to load served, maintaining working clearance required by NEC. E. Electrical equipment, such as switchboards, panelboards, industrial control panels, meter socket enclosures, and motor control centers, that are in other than dwelling occupancies, and are likely to require examination, adjustment, servicing, or maintenance while energized shall be field marked to warn qualified persons of potential electric arc flash hazards. Provide factory labels to comply. F. Where the area above the dedicated electrical space above electrical equipment contains systems which could leak or condensate, provide suitable protection to avoid damage to the electrical equipment. G. All floor mounted electrical gear is to be installed on 4" tall concrete housekeeping pads. ***END OF SECTION*** SECTION 16500 INTERIOR LIGHTING PART 1 - GENERAL 1.01 QUALITY ASSURANCE A. Comply with NEC requirements as applicable to wiring types and lengths for fixture whips. Provide lighting components and fittings that are UL-listed and labeled. PART 2 - PRODUCTS 2.01 MATERIALS A. Lighting fixtures shall be the type indicated on Drawings and as specified. Fixtures of same type shall be of identical make, design, and appearance. Size of lighting fixtures shall be as specified for the lamp or fixture wattage indicated on Drawings. Specific manufacturer and model number references are indicated as a standard of quality and other manufacturers may be supplied provided the product meets or exceeds the specifications. B. Ballasts shall comply with applicable state, federal and industry performance safety standards including FCC requirements governing electromagnetic and radio frequency interference, IEEE standards for line voltage transient protection and harmonic distortion. C. When occupancy sensors are controlling fluorescent fixtures, ballasts shall be programmed rapid start. Instant start is acceptable otherwise. D. Ballasts shall comply with 2008 NEC 410.130 (G) requirement for integral disconnecting means. E. Provide lamps with lighting fixtures. Lamps shall be as manufactured by General Electric, Philips, Venture, or Sylvania. F. Fluorescent lamps shall be 3,000 lumen minimum, 841, 850 for fluorescent high -bays. PART 3 - EXECUTION 3.01 INSTALLATION A. Clean surfaces of dirt, cement, plaster and debris. Furnish cleansers compatible with material surfaces being cleaned. B. Replace defective lamps and ballasts. C. Support recessed fixtures in ceilings as follows: Fixtures shall be independently supported from structure above using (2) #12 ceiling tie -wires per fixture at diagonal corners. D. Recessed fixtures shall fit snugly against ceilings to prevent light leakage. E. Light fixtures and associated wiring shall be installed in accordance with NEC Article 410. F. Where supported via threaded means, all nuts shall be double nutted with lock -washers. ***END OF SECTION*** SECTION 16741 TELEPHONE AND DATA SYSTEM PART 1- GENERAL 1.01 QUALITY ASSURANCE A. Comply with applicable requirements of NEMA and UL standards. Provide products and components that have been UL listed and labeled. PART 2 - PRODUCTS 2.01 MATERIALS A. Outlet boxes shall consist of 4" square deep boxes. Provide minimum 2-1/4" deep boxes unless required otherwise by field conditions. B. Provide backboard in telephone equipment rooms consisting of 3/4" deep X 4' wide X 8' high AC plywood unless noted otherwise on plans. PART 3 - EXECUTION 3.01 INSTALLATION A. Provide minimum 1" conduits from outlet boxes to accessible space above ceiling, terminated with bushing. Where hard ceilings are installed, route conduit to nearest accessible location. B. Paint both sides of telephone backboards with 2 coats of fire retardant paint prior to installation. C. Use long sweep rigid 90-degree elbows on telephone service entrance conduits. D. Provide a ground bar at each telephone backboard location. Provide a #4 Green copper ground from each ground bar to main telephone systems ground or to building grounding electrode system. E. Provide a pull string in all conduits. ***END OF SECTION*** ELECTRICAL LEGEND SYMBOL DESCRIPTION MOUNTING SYMBOL DESCRIPTION MOUNTING O CEILING LIGHT FIXTURE. SEE FIXTURE SCHEDULE. DUPLEX RECEPTACLE. SEE SPECIFICATIONS. 18" AFF TO CENTERLINE UON. ® CEILING LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. DUPLEX RECEPTACLE, ABOVE COUNTER. SEE SPECIFICATIONS. 44" AFF TO CENTERLINE UON. O— WALL WASH LIGHT FIXTURE. ARROW INDICATES WASH DIRECTION. SEE FIXTURE SCHEDULE. DUPLEX RECEPTACLE, ONE-HALF SWITCHED. SEE SPECIFICATIONS. 18" AFF TO CENTERLINE UON. 4 WALL BRACKET LIGHT FIXTURE. SEE FIXTURE SCHEDULE. ® DUPLEX RECEPTACLE, FLOOR OR POKE-THRU. SEE SPECIFICATIONS. FLUSH IN FLOOR UON. WALL BRACKET LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. DOUBLE DUPLEX RECEPTACLE. SEE SPECIFICATIONS. 18" AFF TO CENTERLINE UON. Q WALL BRACKET LIGHT FIXTURE. SEE FIXTURE SCHEDULE. DOUBLE DUPLEX RECEPTACLE, ABOVE COUNTER. SEE SPECIFICATIONS. 44" AFF TO CENTERLINE UON. WALL BRACKET LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. T SIMPLEX RECEPTACLE. SEE SPECIFICATIONS. 18" AFF TO CENTERLINE UON. o WALL MOUNTED SCONCE LIGHT FIXTURE SEE FIXTURE SCHEDULE. CLOCK OUTLET 84" AFF TO CENTERLINE UON. ® WALL MOUNTED SCONCE LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. V SPECIAL RECEPTACLE. NEMA CONFIGURATION AS NOTED. 18" AFF TO CENTERLINE UON. ❑O 1' X 1' LIGHT FIXTURE. SEE FIXTURE SCHEDULE. DUPLEX RECEPTACLE MOUNTED FLUSH IN CEILING. AS NOTED ® 1' X 1' LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. MULTI -OUTLET SURFACE RACEWAY WITH NEMA 5-15R SIMPLEX RECEPTACLES AT 12" CENTERS UON. 44" AFF TO CENTERLINE UON. ® 2' X 2' LIGHT FIXTURE. SEE FIXTURE SCHEDULE. Iffm— 208Y/120V OR 240/120V PANELBOARD. 78" AFF TO TOP. ® 2' X 2' LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. 1295- 277Y/480V PANELBOARD. 78" AFF TO TOP. 2' X 4' LIGHT FIXTURE. SEE FIXTURE SCHEDULE. ,0 DISCONNECT SWITCH. NEMA/AMPS/POLE/FUSE/VOLTAGE. PROVIDE NEMA 1, 600V UON. AS NOTED. 2' X 4' LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. m MOTOR STARTER. AS NOTED. 0 SURFACE MOUNTED LIGHT FIXTURE. SEE FIXTURE SCHEDULE. COMBINATION MOTOR STARTER/DISCONNECT SWITCH. NEMA/AMPS/POLE/FUSE/VOLTAGE. PROVIDE NEMA 1, 600V UON. AS NOTED. SURFACE MOUNTED LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. =DJ ELECTRIC DUCT HEATER. BY OTHERS. WALL MOUNTED LIGHT FIXTURE. SEE FIXTURE SCHEDULE. N MOTOR CONNECTION OR EXHAUST FAN. BY OTHERS. 4 WALL MOUNTED LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. © POWER POLE WITH POWER AND COMMUNICATIONS RACEWAY PROVISIONS AS NOTED. AS NOTED. i--D—� FLUORESCENT STRIP LIGHT FIXTURE. SEE FIXTURE SCHEDULE. v COMMUNICATIONS/DATA OUTLET. 18" AFF TO CENTERLINE UON. FLUORESCENT STRIP LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. ® COMMUNICATIONS/DATA OUTLET, FLOOR OR POKE-THRU. FLUSH IN FLOOR UON. 00— FLOOD LIGHT FIXTURE. SEE FIXTURE SCHEDULE. ® COMBINATION COMMUNICATIONS/DATA AND DUPLEX RECEPTACLE OUTLET, FLOOR BOX. FLUSH IN FLOOR UON. TRACK LIGHT FIXTURE (STRAIGHT). SEE FIXTURE SCHEDULE. ® COMBINATION COMMUNICATIONS/DATA AND QUAD RECEPTACLE OUTLET, FIRE RATED POKE-THRU. FLUSH IN FLOOR UON. �- TRACK LIGHT FIXTURE (CURVED). SEE FIXTURE SCHEDULE. P p FURNITURE SYSTEM BASE FEED (POWER AND DATA), REFER TO NOTES AND SPECIFICATIONS. AS NOTED. PENDANT MOUNTED LIGHT FIXTURE. SEE FIXTURE SCHEDULE. 4 CABLE TV OUTLET. 18" AFF TO CENTERLINE UON. ACCENT LIGHT FIXTURE. SEE FIXTURE SCHEDULE. SECURITY SYSTEM CARD READER OUTLET. 48" AFF TO CENTERLINE UON. CEILING FAN. SEE FIXTURE SCHEDULE. OQ SECURITY SYSTEM CLOSED CIRCUIT TV CAMERA. AS NOTED. ® SINGLE -FACE CEILING MOUNTED EXIT SIGN WITH AIMING ARROWS AS INDICATED. FILL REPRESENTS READABLE FACE DIRECTION. SEE FIXTURE SCHEDULE. ® FAZE ALARM SYSTEM CONTROL PANEL. 78" AFF TO TOP. TWO -FACE CEILING MOUNTED EXIT SIGN WITH AIMING ARROWS AS INDICATED. FILL REPRESENTS READABLE FACE DIRECTION. SEE FIXTURE SCHEDULE. ® FIRE ALARM SYSTEM REMOTE ANNUNCIATOR PANEL. 66" AFF TO TOP. WALL MOUNTED EXIT SIGN WITH AIMING ARROWS AS INDICATED. FILL REPRESENTS READABLE FACE DIRECTION. SEE FIXTURE SCHEDULE. Q FIRE ALARM SYSTEM SMOKE DETECTOR. CEILING UON. WALL MOUNTED EMERGENCY BATTERY PACK LIGHT FIXTURE. SEE FIXTURE SCHEDULE. � s FIRE ALARM SYSTEM DUCT TYPE SMOKE DETECTOR. IN SUPPLY DUCT > 2,000 CFM IN RETURN DUCT > 15,000 CFM COMBINATION EMERGENCY BATTERY LIGHT AND EXIT SIGN WITH AIMING ARROWS AS INDICATED. FILL REPRESENTS READABLE FACE. SEE FIXTURE SCHEDULE. DUCT SMOKE DETECTOR REMOTE TEST STATION. 66" AFF TO CENTERLINE UON. OQ-- POLE MOUNTED LIGHT FIXTURE, ARROW INDICATES OPTICS AIMING. SEE FIXTURE SCHEDULE. © FIRE ALARM SYSTEM HEAT DETECTOR. CEILING UON. SINGLE -POLE TOGGLE OR AUTOMATIC SWITCH. 48" AFF TO CENTERLINE UON. FIRE ALARM SYSTEM PULL STATION. 48" AFF TO CENTERLINE UON. TWO -POLE TOGGLE SWITCH. 48" AFF TO CENTERLINE UON. Ts FIRE ALARM SYSTEM TAMPER SWITCH. FIELD COORDINATE. 3 THREE-WAY TOGGLE OR AUTOMATIC SWITCH. 48" AFF TO CENTERLINE UON. Fs FIRE ALARM SYSTEM FLOW SWITCH. FIELD COORDINATE. FOUR-WAY TOGGLE OR AUTOMATIC SWITCH. 48" AFF TO CENTERLINE UON. ® FIRE ALARM SYSTEM RELAY CONTROL MODULE. FIELD COORDINATE. i° OCCUPANCY SENSOR SWITCH. 48" AFF TO CENTERLINE UON. ❑M FIRE ALARM SYSTEM MONITORING MODULE. FIELD COORDINATE. MOMENTARY CONTACT TOGGLE SWITCH. 48" AFF TO CENTERLINE UON. ❑D FIRE ALARM SYSTEM MAGNETIC DOOR HOLDER. ON WALL 6" BELOW TOP OF DOOR. TIMER SWITCH. 48" AFF TO CENTERLINE UON. FIRE ALARM SYSTEM HORN. 80" AFF TO BOTTOM. 0eo0 DIMMER SWITCH. PROVIDE WATTAGE RATING INDICATED. F DENOTES FLUORESCENT DIMMER. 48" AFF TO CENTERLINE UON. Q FIRE ALARM SYSTEM STROBE, 75 CANDELA UON. 80" AFF TO BOTTOM. Q CEILING MOUNTED OCCUPANCY SENSOR SWITCH. CEILING UON. FIRE ALARM SYSTEM HORN/STROBE, 75 CANDELA UON. 80" AFF TO BOTTOM. JQ E] JUNCTION BOX OR OUTLET BOX. AS NOTED. FIRE ALARM SYSTEM CEILING MOUNTED HORN/STROBE, CANDELA UON. 30' MAX MOUNTING HEIGHT. SURFACE ON CEILING. F-�U GROUND ROD. AS NOTED. MM FIRE ALARM SYSTEM MINI -HORN. 80" AFF TO BOTTOM. CONDUIT CONCEALED IN WALL OR ABOVE CEILING. SEE SPECIFICATIONS. R FIRE ALARM SYSTEM BELL. 96" AFF TO TOP UON. _ � CONDUIT CONCEALED IN SLAB OR UNDERGROUND. SEE SPECIFICATIONS. C UP DN CONDUIT RUN UP OR DOWN AS NOTED. ------- CONDUIT EXPOSED ON WALL OR CEILING. SEE SPECIFICATIONS. PHASE, NEUTRAL, EQUIPMENT GROUND, AND ISOLATED GROUND. ALL HOMERUNS SHALL BE MINIMUM 1/2" CONDUIT WITH 3 #12, UON. LINE SHADING FOR EXISTING ELECTRICAL /C PC TIME CLOCK / PHOTOCELL LINE SHADING FOR NEW ELECTRICAL 00 REFER TO KEYED NOTES. ABBREVIATIONS ABBREVIATIONS AFF ABOVE FINISHED FLOOR. HID HIGH INTENSITY DISCHARGE. AFG ABOVE FINISHED GRADE. HP HORSEPOWER. ATS AUTOMATIC TRANSFER SWITCH. IG ISOLATED GROUND. BIG BELOW FINISH GRADE. LCP LIGHTING CONTROL PANEL C CONDUIT. LSIG LONG, SHORT, INSTANTANEOUS & GROUND FAULT TRIP SETTINGS (ALL ADJUSTABLE). CLG CEILING MOUNTED. N NEW. D DEMOLITION NEUT NEUTRAL. DN CONDUIT DOWN. NF NON -FUSED. E EXISTING. NL NIGHT LIGHT. EC ELECTRICAL CONTRACTOR. NP NAMEPLATE. EG EQUIPMENT GROUND. OFCI OWNER FURNISHED, CONTRACTOR INSTALLED. EXP EXPLOSION PROOF. PNL PANEL. EWC ELECTRIC WATER COOLER. RE RELOCATED. EWH ELECTRIC WATER HEATER. UON UNLESS OTHERWISE NOTED. GEC GROUNDING ELECTRODE CONDUCTOR. UPS UNINTERRUPTIBLE POWER SUPPLY. GFI GROUND FAULT INTERRUPTER (BREAKER) / GROUND FAULT CIRCUIT INTERRRUPTER (RECEPTACLE). WP WEATHERPROOF. FTL FEED THRU LUGS (FEED DOWNSTREAM SECTION WITH IDENTICAL FEEDER AS PREVIOUS SECTION) XFMR TRANSFORMER THE DESIGN FLOOD ELEVATION IS 12" AFF, UON. 0 w a 0 a 0 U UJ UJ LU Of Z 0 0 z LU m J J Q U O a X UJ 0 Z Q Z 0 0 w Z w 0 0 0 z Cdr1C Architecture, I nc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 m `.J a w U 0 E N H E~ ° wV `n U WE`r'Lr F" CO o O r�, v om-4 N �J) v o 0 w w 1� �� w 4 0 z �n m rn No. 58722 ®'a •''0 STATE OF `°•• •' �O N LID ch J Q _J LL -�--� U) J t UJ IY I J N Q PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 rl I�nl-r� FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION LEC;END, 5PEC'5 CONTINUED MDO PROJECT #: 14-87 E002 10/15/14 IV LIGHTING NOTES O 1. EXISTING FIXTURE TO BE RELOCATED TO POSITION SHOWN AND RE -CIRCUITED AS NOTED. 2. EXISTING FIXTURE TO BE RELOCATED TO POSITION SHOWN, PROVIDE NEW 1100 LUMEN MIN. EMERGENCY BATTERY BALLAST AND RECIRCUIT AS NOTED. 3. CONNECT EXIT LIGHT TO UNSWITCHED HOT LEG OF LOCAL LIGHTING CIRCUIT. 4. CONNECT EMERGENCY BATTERY BALLAST TO UNSWITCHED HOT LEG OF LIGHTING CIRCUIT. 5. ROUTE HOMERUN FOR SIGN CIRCUIT VIA TIME CLOCK. PROVIDE TORK MODEL 7100 (OR EQUIVALENT) TIME CLOCK MOUNTED ADJACENT TO PANEL. 6. SHOW WINDOW RECEPTACLE ABOVE WINDOW, TYP. 7. WALL MOUNTED, DUAL TECHNOLOGY, LINE VOLTAGE OCCUPANCY SENSOR EQUAL TO WATT STOPPER #DW-100. 8. POWER PACK FOR LOW -VOLTAGE OCCUPANCY SENSORS, UP TO 225mA SENSOR LOAD PER POWER PACK. POWER PACK EQUIVALENT TO WATT BZ150 (120/277V). 9. CEILING/PENDANT MOUNTED OCCUPANCY SENSOR, LOW VOLTAGE, EQUIVALENT TO WATT STOPPER DT-300 (43mA), WIRED TO POWER PACK. 10. CEILING MOUNTED, DUAL TECHNOLOGY, LINE VOLTAGE OCCUPANCY SENSOR EQUAL TO WATT STOPPER #DT-355. 11. TOGGLE SWITCH TO BE WIRED TO LOAD SIDE OF OCCUPANCY SENSOR FOR MANUAL "OFF" CONTROL. 12. JUNCTION BOX FOR SIGN, FIELD VERIFY EXACT LOCATION AND REQUIREMENTS WITH SIGN CONTRACTOR. GENERAL NOTES 1. ALL 120V CIRCUIT LENGTHS GREATER THAN 100 FT SHALL BE INCREASED TO #10 AWG AND TO # 8 AWG WHEN GREATER THAN 160 FT. INCREASE CONDUIT SIZE FOR 40% FILL. 2. WHERE MORE CONDUCTORS ARE SHOWN THAN CIRCUITS, EXTRA HOT CONDUCTOR IS FOR EMERGENCY BATTERY BALLAST AND/OR NIGHT LIGHTS AND SHALL NOT BE SWITCHED. 3. WHERE A SHARED NEUTRAL CONDUCTOR IS USED FOR MULTIPLE BRANCH CIRCUITS, CONTRACTOR SHALL GROUP CIRCUITS TOGETHER IN PANEL AND PROVIDE A MANUFACTURER FURNISHED HANDLE -TIE TO SIMULTANEOUSLY TRIP ALL OF THE CIRCUITS SHARING THE NEUTRAL. 4. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA ENERGY CONSERVATION CODE 505.7.3 HAS BEEN TAKEN INTO ACCOUNT FOR THIS PROJECT. FIXTURE SCHEDULE SYMBOL MANUFACTURER MODEL NUMBER LAMPS MOUNTING FIXTURE WATTAGE DESCRIPTION METALUX 2GR8-332-A125-120-EB81 HUBBELL EQUIVALENT (3) 32W T8, 3,000 2' x 4', FLUORESCENT TROFFER WITH 0.125" ACRYLIC A RECESSED 81W LITHOMA EQUIVALENT LUMEN MIN LENS, 120V. PHILIPS EQUIVALENT METALUX 2GR8-332-A125-120-EB81-EL HUBBELL EQUIVALENT (3) 32W T8, 3,000 SAME AS TYPE 'A', EXCEPT WITH 1100 LUMEN 90 MIN. AE RECESSED 81W LITHONIA EQUIVALENT LUMEN MIN BATTERY BALLAST. PHILIPS EQUIVALENT EXISTING EXISTING (3) 32W T8, 3,000 RE RECESSED 81W 2' x T, 18 CELL FLUORESCENT PARABOLIC TROFFER,120V. LUMEN MIN PORTFOLIO LD615D010-ERM6835-6LM1-LI OMEGA EQUIVALENT 1500 LUMEN RECESSED IN 6" DIAM. LED DIMMABLE DOWNLIGHT, 120V. UL LISTED D LITHONIA EQUIVALENT LED CEILING 25W FOR PROTECTED WET LOCATIONS. PROVIDE MATCHING DIMMER SWITCH WHERE NOTED. PHILIPS EQUIVALENT HALO LZR-104-P-LZR200-DE112 W/(#) HUBBELL LZR404P HEADS TR 50W MR16 CEILING 50W TRACK LIGHTING, QTY HEADS SHOWN, 120V LITHONIA PHILIPS LUMARK XTORIA HUBBELL EQUIVALENT 734 LUMEN LED SURFACE ON LED FULL CUTOFF WALL LIGHT, COLOR SELECTION BY W1 LITHONIA EQUIVALENT BY MFR WALL AT 8'-0" 8W OTHERS, 120V. PHILIPS EQUIVALENT SURE-LITES LPX-70-RWH HUBBELL EQUIVALENT SURFACE ON UNIVERSAL LED EXIT SIGN WITH INTEGRAL 90 MIN. X L.E.D. WALL 6" ABOVE 1W LITHONIA EQUIVALENT DOOR BATTERY BACKUP, 120V. PHILIPS EQUIVALENT ledFiCk Architecture, I nc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 38444 5TH AVE. ZEPHYRHILLS, FL 33542 FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 MDO PROJECT # 10/15/14 POWER NOTES O 1 I I 4. N3 1. PROVIDE TX TX 3/4" FIRE RETARDANT PAINTED PLYWOOD TELEPHONE BACKBOARD WITH TOP AT T AFF. EXTEND #6 CU FROM BACKBOARD TO GROUNDING ELECTRODE SYSTEM. EXTEND 1"C WITH PULLWIRE TO EXISTING TEL. SVC PNL LOCATED IN RM 120. 2. PROVIDE WIREMOLD SERIES ALA4800 TWO CHANNEL SATIN ANODIZED AL WIREWAY WITH OUTLETS 18 ON CENTER (TOP CHANNEL MOUNT). LOWER CHANNEL FOR DATA CABLES. 3. ENTIRE CIRCUIT TO BE ON GFCI BREAKER. 4. PROVIDE JUNCTION BOX WITH 120V CIRCUIT AS INDICATED ABOVE DOOR. GENERAL NOTES 1. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. 2. ALL GROUNDING ELECTRODE SYSTEMS SHALL BE INTERCONNECTED PER NEC 250.52. 3. ALL 120V CIRCUIT LENGTHS GREATER THAN 100 FT SHALL BE INCREASED TO #10 AWG AND TO # 8 AWG WHEN GREATER THAN 160 FT. INCREASE CONDUIT SIZE FOR 40% FILL. 4. REFER TO HVAC WIRING SCHEDULE FOR CIRCUITING REQUIREMENTS OF SAME. 5. WORKING CLEARANCE SHALL BE AFFORDED TO ALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC 110.26. 6. ALL 15 & 20A,120V RECEPTACLES WITHIN 6FT OF A SINK SHALL BE GFCI PROTECTED. 7. WHERE A SHARED NEUTRAL CONDUCTOR IS USED FOR MULTIPLE BRANCH CIRCUITS, CONTRACTOR SHALL GROUP CIRCUITS TOGETHER IN PANEL AND PROVIDE A MANUFACTURER FURNISHED HANDLE -TIE TO SIMULTANEOUSLY TRIP ALL OF THE CIRCUITS SHARING THE NEUTRAL. 8. WHERE COMMUNICATIONS OUTLETS ARE SHOWN ADJACENT TO POWER RECEPTACLES, BOTH SHALL BE INSTALLED AT THE SAME ELEVATION. 9. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA ENERGY CONSERVATION CODE 505.7.3 HAS BEEN TAKEN INTO ACCOUNT FOR THIS PROJECT. HVAC & PLUMBING EQ. WIRING SCHEDULE UNIT NUMBER MCA MOCP DISCONNECT BRANCH CIRCUIT SWITCH FUSES CONDUIT WIRE PANEL AHU-1 50 50 N1/60/2/240V -- 1" 2 #6 & 1 #10 EG L-61,63 AHU-2 45 45 N1/60/2/240V -- V 2 #6 & 1410 EG L-65,67 AHU-3 45 45 N1/60/2/240V -- 1" 2 #6 & 1 #10 EG L-69,71 AHU-4 48 50 N1/60/2/240V -- 1" 2 #6 & 1 #10 EG L-73,75 CU-1 35 60 N3R/60/2/240V -- 3/4" 2 #8 & 1 #10 EG L-64,66 CU-2 20 35 N3R/60/2/240V -- 1/2" 2 #12 & 1 #10 EG L-68,70 CU-3 20 35 N3R/60/2/240V — 1/2" 2 #12 & 1 #10 EG L-72,74 CU-4 28 50 N3R/60/2/240V -- 3/4" 2 #10 & 1 #10 EG L-76,78 EWH 12.5 20 NI/30/2/240 -- 3/4" 2 #10 & 1 #10 EG L-77,79 TEF-1 WTFH FAN -- 1/2" 2 #12 & 1 #12 EG WITH LIGHTS TEF-2 WITH FAN -- 1/2" 2 #12 & 1 #12 EG WITH LIGHTS System No. W-L-1049 F Ratings -1 and 2 Hr (See Item 1) T Rating -0 Hr L Rating At Ambient -Less Than 1 CFM/sq ft L Rating At 400 F -Less Than 1 CFM/sq ft Section A -A Wall Assembly -The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 3-5/8 3-1/2 in. (89 mm) wide and spaced max 24 in. (610 mm) OC. When steel studs are used and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed between the vertical studs and screw -attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. (102 to 152 mm) wider and 4 to 6 in. (102 to 152 mm) higher than the diam of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 in. (51 to 76 mm) clearance is present between the penetrating item and the framing on all four sides. B. Gypsum Board* -5/8 in. (16 mm) thick, 4 ft (1.22 m) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 26 in. (660 mm) for steel stud walls. Max diam of opening is 14-1/2 in. (368 mm) for wood stud walls. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 1A. Metallic Sleeve -(Optional, Not Shown) - Cylindrical sleeve fabricated from min 0.016 in. (0.41 mm) to max 0.105 in. (2.7 mm) thick sheet steel. Length of steel sleeve to be equal to the thickness of wall. Longitudinal seam of sleeve welded or overlapped min 1 in. (25 mm). The ends of the steel sleeve shall be flush or recessed max 1/4 in. (6 mm) from wall surfaces. 2. Through Penetrant -One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. The annular space between pipe, conduit or tubing and periphery of opening shall be min 0 in. (0 mm, point contact) to max 2 in. (51 mm). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe -Nora 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe -Nora 24 in. (610 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit -Nora 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing, nom 6 in. (152 mm) diam (or smaller) steel conduit or nom 1 in. (25 mm) diam (or smaller) flexible steel conduit. D. Copper Tubing -Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe -Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* -Sealant -Min 518 in. (16 mm) thickness of fill material applied within annulus, flush with both surfaces of wall. At the point contact location between through penetrant and gypsum board, a min 3/8 in. (10 mm) diam bead of fill material shall be applied at the gypsum board/through penetrant interface on both surfaces of wall. SPECIFIED TECHNOLOGIES INC -SpecSeal Series SSS Sealant or SpecSeal LCI Sealant *Bearing the UL Classification Mark led 1Ck Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 L\ c-i cm r r� V m w w H � � v w � � o0 �J F" "' Ln o N � w M o w Ln 0 z 00 M a, N N VV `eq�``�y,�p� ,,...•v.V, U� jttp'����s� e No.58722 STATE OF '•�� .,S N Z `e a.i Q LO 00 M N Ln co C`7 J LL U) ---! J_ LLI N PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 EM DATE I DESCRIPTION I POWER PLAN Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. &W-L-1 1 1 Created or Revised: December 14,20101 1 049 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com PAGE 1 OF 1 POWER FLAN 3/1(0"=1'-011 MDO PROJECT #: 14-87 E201 10/15/14 f ON- PANEL: L ACCESSORIES: PROVIDE WITH FEED THRU LUGS VOLTAGE: 240 /120 PHASE: 3 MOUNTING: SURFACE AMPS: 200 AMP MCB WIRE: 4 NEMA:1 AIC: 22,000 LOAD (KVA) LOAD (KVA) LTG REC MISC COOL HEAT MTR LOAD DESCRIPTION U A B C LOAD DESCRIPTION LTG REC MISC COOL HEAT MTR 1.3 20 1 120-123, 125 LTG 1 2 SHOW WINDOW RECEPT 20 1 0.8 HIGHLEG 3 4 HIGHLEG 1.2 20 1 LAB 119 5 6 OFFICE 112-116 20 1 0.9 1.1 20 1 SALES 7 8 105,106,117,118 20 1 0.5 HIGHLEG 9 10 HIGHLEG 0.9 20 1 SALES, PHARMACY 11 12 109-111 20 1 0.7 1.0 20 1 SIGN CIRCUIT 13 14 ADMIN 108 20 1 1.0 HIGHLEG 15 16 HIGHLEG 0.7 20 1 DISP 121 17 18 LAB-119 (1) 20 1 0.9 0.8 20 1 DISP 121 19 20 LAB-119 (1) 20 1 0.9 HIGHLEG 21 22 HIGHLEG 0.9 20 1 LAB 119 23 24 LAB-119 (1) 20 1 0.9 0.9 20 1 LAB 119 25 26 LAB-119 (1) 20 1 0.9 HIGHLEG 27 28 HIGHLEG 0.9 20 1 LAB 119 29 30 LAB-119 20 1 0.9 0.9 20 1 LAB 119 31 32 LAB-119 20 1 0.9 HIGHLEG 33 34 HIGHLEG 0.9 20 1 LAB 119 35 36 REFRIGERATOR 20 1 0.8 0.9 20 1 LAB 119 37 38 BREAK ROOM 20 1 0.9 HIGHLEG 39 40 HIGHLEG 0.7 20 1 IT 123 41 42 BREAK ROOM 20 1 09 0.9 20 1 IT 123 43 44 BREAK ROOM 20 1 0.9 HIGHLEG 45 46 HIGHLEG 1.1 20 1 OFFICE 114,116 47 48 BREAK ROOM 20 1 0.9 1.1 20 1 111,110 49 50 EWC 20 1 0.4 HIGHLEG 51 52 HIGHLEG 0.6 20 1 PHARMACY 53 54 ADMIN 108 20 1 1.1 0.7 20 1 108,112, 113 55 56 OFFICE 109 20 1 1.1 HIGHLEG 57 58 HIGHLEG 1.0 20 1 COPIER 59 60 SALES 101 20 1 0.8 3.8 0.8 50 2 AHU-1 61 62 DOOR ACCESS 20 1 1.1 3.8 0.8 - - 63 64 CU-1 60 2 3.3 3.8 0.6 45 2 AHU-2 65 66 -- - 3.3 3.8 0.6 - - 67 68 CU-2 35 2 1.9 3.8 0.6 50 2 AHU-3 69 70 -- - 1.9 3.8 0.6 - - 71 72 CU-3 35 2 1.9 3.8 0.8 50 2 AHU-4 73 74 -- - 1.9 3.8 0.8 - - 75 76 CU-4 50 2 2.8 1.8 20 2 EWH 77 78 -- - 2.8 1.8 - - 79 80 SPD 30 3 HIGHLEG 81 82 -- - 0.4 20 1 DOOR ACCESS 83 84 STORAGE 20 - 1 0.9 CONNECTED LOAD SUMMARY (KVA) DEMAND LOAD SUMMARY A B C TOTALS D.F. COMMENTS LOAD LTG 4.9 0.0 3.8 8.7 1.25 10.8 KVA REC 12.9 0.0 14.9 27.8 0.68 100% OF FIRST 10 KVA PLUS 50% OF REMAINDER 18.9 KVA MISC 2.8 0.0 2.1 4.9 1.00 4.9 KVA COOL 3.8 8.0 8.0 19.9 0.0 KVA HEAT 11.5 11.5 7.7 30.7 1.00 HEATING LOAD USED FOR CALCULATION 30.7 KVA MTR 1 2.2 1 2.2 1 1.3 1 5.7 1.07 125% OF LARGEST MOTOR PLUS 100% OF REMAINDER I 6.1 KVA PHASE BALANCE 11 % -15 % 5% Breaker Notes O: DEMAND LOAD: 71.5 KVA DEMAND CURRENT: 171.9 AMPS 1. PROVIDE GFCI BREAKER 2. 3. 4. 5. 6. VOLTAGE DROP CALCULATION FEEDER ORIGIN DESTINATION VOLTAGE PHASE LENGTH LOAD SETS SIZE TYPE VOLTAGE DROELL 1 UTILITY PANEL'L' 240 3 80 170 1 3/0 CU 0.63 NOTE: FEEDER LENGTHS INDICATED IN THIS TABLE ARE NOT TO BE USED FOR BIDDING PURPOSES. CONTRACTOR SHALL DETERMINE FEEDER LENGTH FOR BIDDING PURPOSES AND NOTIFY ENGINEER IF THEIR PROPOSED ROUTING IS MORE THAN 10% DIFFERENT THAN SHOWN DURING BID. FAULT CURRENT CALCULATION UTILITY/ORIGIN VOLTS: 240 TRANSFORMER KVA 75 UTILITY/ORIGIN FAULT: 31539 FEEDER ORIGIN DESTINATION ORIGIN DESTINATION LENGTH WIRE I SIZE I SETS X/R RATIO FAULT X/R RATIO FAULT UTILITY PANEL'U 80 CU 1 3/0 1 12.00 31539 1.26 15641 GENERAL NOTES: 1. PANEL AIC RATING MUST BE GREATER THAN OR EQUAL TO DESTINATION FAULT VALUE IN TABLE ABOVE. 2. THE FAULT CURRENT STUDY IS BASED ON THE TRANSFORMER SIZE INDICATED ABOVE. 3. THE ELECTRICAL CONTRACTOR SHALL CONFIRM UTILITY TRANSFORMER AVAILABLE FAULT CURRENT PRIOR TO ORDERING GEAR. 4. THE ELECTRICAL CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY IF FAULT CURRENT IS DIFFERENT THAN INDICATED ABOVE. 5. SERIES RATING OF CIRCUIT BREAKERS IS PERMITTED EXCEPT WHERE TOTAL SYSTEM MOTOR FULL LOAD AMPS EXCEEDS 100 AMPS. 6. WHERE SERIES RATING IS UTILIZED, PROVIDE MANUFACTURERS TESTING DOCUMENTATION FOR ALL BREAKERS WITH SUBMITTALS. 7. FEEDER LENGTHS INDICATED IN THIS TABLE ARE NOT TO BE USED FOR BIDDING PURPOSES. CONTRACTOR SHALL DETERMINE FEEDER LENGTH FOR BIDDING PURPOSES AND NOTIFY ENGINEER IF THEIR PROPOSED ROUTING IS MORE THAN 10% DIFFERENT THAN SHOWN DURING BID. 7 N.T.S. RISER NOTES O 1. EXISTING METER TO REMAIN. 2. EXISTING (3) #3/0, #3/0 N SERVICE LATERAL CONDUCTORS TO REMAIN. 3. EXISTING WIREWAY TO REMAIN. 4. REMOVE EXISTING REDUCED SIZED FEEDER AND EXTEND EXISTING (3) #3/0 & (1) #3/0 N SERVICE LATERAL TO EXISTING METER. 5. PROVIDE NEW #4 SERVICE GROUND TO EXISTING GROUND RODS. 6. SURGE PROTECTIVE DEVICE (SPD) NIPPLED TO TOP OF SWITCHBOARD, PQ PROTECTION #PQM200 (120/240) OR EQUIVALENT. CIRCUIT VIA 5 #10 IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. RISER GENERAL NOTES 1. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA ENERGY CONSERVATION CODE 505.7.3 HAS BEEN TAKEN INTO ACCOUNT FOR THIS PROJECT. 9 FEEDER SCHEDULE COPPER ALUMINUM SYMBOL NOTES CONDUCTORS (THWN/THHN) CONDUIT SIZE CONDUCTORS (XHHW) CONDUIT SIZE PER SET PER SET SETS PHASE & NEUTRAL I GROUND SETS PHASE & NEUTRAL GROUND 200 1 4 #3/0 1 #6 2" 1 4 #250 KCMIL 1 #4 3" ABBREVIATIONS: S = SERVICE T = UPSIZED EG DUE TO TAPPED CONDUCTORS PER NEC 250.122(G) P = PHASE ONLY (SINGLE PHASE WITH NEUTRAL OR THREE PHASE WITH NO NEUTRAL) U = UNDER -RATED (WIRE RATED LESS THAN THE FULL AMPACITY RATING OF THE BREAKER) R = GALVANIZED RIGID CONDUIT SERVICE MAST AND WEATHERHEAD IG = ADDITIONAL GROUND CONDUCTOR FOR ISOLATED GROUND E = EXISTING VD = VOLTAGE DROP DEMO IR15ER DIAGRAM N.T.S. 0 w Q 0 a x 0 U U) LLJ z 0 CL 0 w z h W w m J Q x WiedFick AL Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727,736.8627 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 n m V a w � o Cm 1W d F-1 2 o rn � _ � 0 IN m m .�2 �ZU w 0 ?< m w H��� Ln 0 z 00 m cm 011 A, \GEA '® A ' No.58722 %'o • STATE OF '• �� • tV o O IOP' ; Gx �, z o O ai (Y) Q c� J LL +� co Ln J 'ITJ LU a. PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION POWER RISER DIAGRAM 4 5CHEDULE5 MDO PROJECT #: 14-87 E301 10/15/14 DRAINING INDEX A55REVIATION6 t__ � AFF ABOVE FINISHED FLOOR HM HOLLOW METAL > C k > ` CJ CONTROL JOINT HORIZ HORIZONTAL ARCHITECTURAL CONC CONCRETE MIN MINIMUM _ Cx001 TITLE SHEET • DBL DOUBLE MO MASONRY OPENING A100 LIFE SAFETY PLAN --- ` DIA DIAMETER MTL METAL A101 DEMOLITION FLOOR PLAN • DIM DIMENSION NFHB NON FREEZE HOSE BIB A102 NEW FLOOR PLAN • IDS DOWNSPOUT NIC NOT IN CONTRACT A103 NEW CEILING PLAN • EWC ELECTRIC WATER COOLER NTS NOT TO SCALE A104 FURNITURE PLAN • EXT EXTERIOR OC ON CENTER FE FIRE EXTINGUISHER PT PRESSURE TREATED A400 ENLARGED PLANS FFE FINISH FLOOR ELEVATION RL ROOF LEADER PIPE A401 DETAILS • FRP FIRE RATED PROTECTED A600 DOOR AND FINISH SCHEDULE • FRT FIRE RETARDANT TREATED A601 DOOR DETAILS _ — FOB FACE OF BLOCK PLUMBING GALV GALVANIZED PI00 PLUMBING PLAN • GC GENERAL CONTRACTOR GWB GYPSUM WALL BOARD P101 PLUMBING ISOMETRIC • GYP GYPSUM MECHANICAL HC HANDICAP M100 MECHANICAL PLAN —— _ • ANNOTATION 6" ®I M101 SCHEDULE AND NOTES • *— P-LECTRICAL �,T�c DRAWINGBLOCK TITLEFINS >: C4 m r 0 - Sheet 002 ELECTRICAL LEGEND _ �i• A - Title E101 _LkGHTING PLAN -- • _ Number Scale i E201 POWER PLAN • - �� �Detai! Area Outline E202 ENLARGED POWER PLAN ® �' • E301 POW,IER RI5ER AND SCHEDULE • DRAWING LABEL DETAIL LABEL — - - -- - - - No. 0 Designatian - WALL SECTION LABEL GRID REFERENCE F-Elevation from -- ---- ------ -- - - No. 0i Finished Floor :?(; ___-- - 5heet -000 lip ELEVATION LABEL ELEVATION LEVEL I NTERIOR AL TERA TION: 38444 5TH AVE. ZEPHRHILLS, FL 33542 CODS SUMMARY LOCATION: ........................ — 3844 5TH AVE. ................................ ZEPHYRHILLS, FL 33542 SITE ZONING: ............................ ...................COMMERCIAL FLORIDA BUILDING CODE .................................................... 2010 FLORIDA EXISTING BUILDING CODE ........................................ 2010 FLORIDA MECHANICAL CODE ................................ I .............. 2010 FLORIDA PLUMBING CODE .................................................. 2010 NATIONAL ELECTRIC CODE .. ............................................... 2008 FLORIDA FIRE PREVENTION CODE ........................................ 2010 PLEASE REFERENCE THE SCOPE OF WORK AND BUILDING DATA FOR ADDITIONAL INFORMATION. =ROiECT TEAM I SCOPE OF WORK I BUILDING DATA I PROJECT GENERAL NOTES 0UjI E R: FLORIDA PHARMACY SOLUTIONS, INC. 139,73 11TH ST. SUITE 300 DADE CITY, FLORIDA 33525 ARCHITECT WIEDRICK ARCHITECTURE, INC. 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA 34698 MR, WES M065 TEL 855-111-1998 wes.mossofps-rx.com MATTHEW WIEDRICK TEL 121-261-2300 matth-wsw iedr ickarchitecture.com MECHANICAL $ PLUMBING ENGINEER SEEDS ENGINEERING, INC. JOHN MAKAR P.E. 21130 SANTA ANITA BLVD. TEL 813-902-2515 WESLEY CHAPEL , FL 33544 FAX 813-9W2-2516 jmakarilseedseng.com ELECTRICAL ENGINEER OTTO ENGINEERING, INC. 9385 NORTH 56TH STREET, SUITE 200 TEMPLE TERRACE, FL 33611 DATE DESCRIPTION OS/2244 REVIEW SET 10/15/14 PERMIT SET 1241114 REV 01 MATT OTTO P.E. TEL 813-985-8555 FAX 813-985-4555 mattott000ttoeng inc.com PRINT RECORD THIS 15 AN ALTERATION TO THE EXISTING FIRST FLOOR TENANT SUITE LOCATED AT 3844 5TH AVE. BASED ON THE 2010 FBC ZEPHRHILLS FLORIDA 33542. THE AFFECTED AREA 15 APPROXIMATELY 5SO SQUARE FEET. THE EXISTING SUITE 15 APPROXIMATELY 5,SO SQUARE FEET. THE PURPOSE OF THIS ALTERATION IS TO . AFFECTED AREA. ............ ................................................................ 5,960 SF BUILD -OUT THE SPACE INTO A FUNCTIONING MIXED USE (MERCANTILE AND BUSINESS) OCCUPANCY. THE SCOPE INCLUDES MODIFICATIONS TO THE EXISTING MECHANICAL AND ELECTRICAL SYSTEMS. OCCUPANCY TYPE ...........................................BUSINESS AND MERCANTILE THIS ALTERATION IS SUBMITTED USING THE PRESCRIPTIVE METHOD AS DEFINED IN THE FLORIDA CONSTRUCTION TYPE ..................................... EXISTING (V-B) - NO CHANGE BUILDING CODE - EXISTING BUILDING. SPRINKLERED........................................................................................... NO THE FOLI-OWING IS A BRIEF SUMMARY OF THE APPLICABLE CODE SECTIONS FROM THE 2010 FLORID;'~ BUILDING CODE - EXISTING BUILDING AND THE FLORIDA FIRE PREVENTION CODE: OCCUPANT LOAD - TABLE 1004.1.1 CHAPTER ONE - SCOPE AND ADMINISTRATION MERCANTILE - GRADE FLOOR AREAS (100 SQFT/30 GROSS) 24 SE !:,�TION 1015.1 COMPLIANCE METHODS: ................ REPAIRS, ALTERATIONS, ADDITIONS AND CHANGES OF OCCUPANCY COMPLYING: WITH BUSINESS - (3,335 SQFT/100 GRO55)........................................................ 34 A CHAPTER 3 OF THIS CODE IN BUILDINGS COMPLYNG WITH THE FLORIDA FIRE PREVENTION CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS OF THIS CODE. KITCHEN (FRONT OF HOUSE) - (192 SQFT/200 GROSS) .............................. CHAPTER 3- PRESCRIPTIVE COMPLIANCE METHOD STORAGE - (1135 5QFT/300 GROSS).......................................................... 4 SECTION 303 ALTERATIONS: EXCEPT AS PROVIDED BY SECTION 3012 OR THIS SECTION, ALTERATIONS TO ANY BUILDING TOTAL OCCUPANT LOAD...........................................................................63 OR STRICTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NO LESS CONFORMING WITH THE PROVISIONS OF THE FLORIDA MEANS OF EGRESS BUILDING CODE, BUILDING THAN THE EXISTING BUILDING OR STRICTURE WAS PRIOR TO THE ALTERATION. TOTAL EGRESS WIDTH REQUIRED (63 OCCUPANTS X 02).........................13" 2010 FLORIDA FLORIDA FIRE PREVENTION CODE PROVIDED ............................................... ........................................... ....... 160" CHAPTER 14 - MEAN OF EGRESS MINIMUM NUMBER OF EXITS REQUIRED (FBC 1021.1) .................................... 2 SECTION 142 EXIT ACCESS CORRIDORS: CORRIDORS USED AS EXIT ACCESS AND SERVING: AN OCCUPANT LOAD EXCEEDING 30 PROVIDED AND MARKED W/EMERC�ENCY LIGHT 5IGNAGE ....................... 4 SHALL BE SEPARATED FROM OTHER PARTS OF THE BUILDING BY WALLS HAVING NOT LESS THAN A I -HOUR FIRE RESISTANCE RATING IN ACCORDANCE WITH SECTION 12.1 UNLESS New Exit 'A' Width 9 3211 OTHERWISE PERMITTED BY THE FOLLOWING: A L THIS REQUIREMENT SHALL NOT APPLY TO EXISTING BUILDINGS PROVIDED THAT THE Existing Exit 'B' Width 66411 OCCUPANCYCLAWIFICATION DOES NOT CHANGE Existing Exit 'C' Width 32" 2. THIS REQUIREMENT SHALL NOT APPLY WHERE OTHERWISE PROVIDED IN CHAPTERS 11 TOTAL 128" THROUG44 43 OF NFPA 101:1.13.1 THE EXISTING SPACE IS NOT SPRINKLED MAXIMUM TRAVEL DISTANCE ALLOWED - FBC TABLE 1016.1 ALL FIRE ALARM WOK INCLUDING CHANGES, ADDITIONS, RELOCATIONS, IMPROVEMENTS, AND/OR MERCANTILE I.... 150 FT. MODIFICATIONS TO THE FIRE ALARM SYSTEM MUST BE DONE PER NFPA -12 2001 EDITION BY A .................................................................................. LICENSED FIRE ALARM CONTRACTOR WITH SEPARATE PERMIT AND PLANS BUSINESS ....................... PLEASE REFERENCE THE CODE SUMMARY (COVER SHEET) AND BUILDING DATA SECTIONS FOR PROVIDED................................................................................... I ... • • .. 122 FT. ADDITIONAL INFORMATION. _ _: `` ° '�.. �,u .. a' 11 �. PLEASE REFERENCE THE SCOPE OF WORK FOR ADDITIONAL INFORMATION FLORIDA PRODUC � APPROV,4L5 PRODUCT CATEGORY: SUB CATEGORY: MANUFACTURER EXTERIOR DOORS EXTERIOR DOOR COMPONENTS CECO DOOR PRODUCTS OMITTED STRUCTURAL COMPONENTS STRUCTURAL WALL 5ERRIDGsE MODEL/NAME: MIAMI DADE APPROVAL SWINGING HOLLOW METAL FL4553.1 DOOR AND FRAME "THINLINE" wall panel I FL 1466'n 1. THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND SHALL CONFIRM THAT WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSION, ETC., SHALL BE IMMEDIATELY REP07TED TO THE ARCHITECT FOR CLARIFICATION PRIOR TO THE PERFORMANCE OF ANY WORK IN QUESTION. 2. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN ALL PARTITION LOCATIONS. ALL DOOR AND OPENING LOCATIONS SHALL BE ON FLOOR PLAN. IN CASE OF CONFLICT, NOTIFY THE ARCHITECT. ALL DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES INCLUDING CARPET, PAD, TILE, VINYL, WAINSCOT, ETC. 3. CONTRACTOR SHALL COORDINATE AND OBTAIN ALL NECESSARY APPROVALS AND INSPECTIONS AS REQUIRED BY LOCAL GOVERNING JURISDICTIONS. 4. THE CONTRACTOR 15 EXPECTED TO KEEP PREM15E5 CLEAN DURING CONSTRUCTION. TRASH WILL NOT BE ALLOWED TO ACCUMULATE IN THE SPACE DURING CONSTRUCTION. ALL DEBRIS SHALL BE REMOVED DAILY. FINAL CLEAN UP AND REPAIR 15 PART OF THIS WORK REMOVE ALL DUST, DEBRIS, OILS, STAINS, FINGERPRINTS AND LABELS FROM ALL EXPOSED FINISHED SURFACE:' SAFE WORKING AREA AND CONDITIONS SHALL BE MAINTAINED AT ALL TIMES. 5. It 15 THE CONTRACTOR'S RESPONSIBILITY TO FURNISH AND INSTALL ALL WORK FIXTURES AND EQUIPMENT NECESSARY TO COMPLETE PROJECT AS PER PLANS - UNLESS NOTED OTHERWISE. THE CONTRACTOR 15 TO DELIVER PROJECT CLEAN AND READY FOR USE AS APPROVED BY TENANT/OWNER 6. THE CONTRACTOR SHALL VERIFY LOCATIONS OF EXISTING UTILITIES BEFORE COMMENCING WORW, CARE SHALL BE TAKEN TO PROTECT ALL UTILITIES WHICH ARE TO REMAIN. 1. ALL REQUESTS FOR SUBSTITUTIONS OF ANY NON -VENDOR SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND WILL BE CONSIDERED ONLY IF THE ALTERNATE PROPOSED 15 PROVEN TO BE MORE ADVANTAGEOUS TO THE OWNER WITH RESPECT TO DELIVERY DATE, =.ALITY, OR COST. ALL VENDOR SUPPLIED ITEMS ARE EXCLUDED AND MAY NOT BE SUBSTITUTED. UNDER NO CIRCUMSTANCES WILL THE ARCHITECT BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION 15 OR 15 NOT OF EQUAL QUALITY TO THE PRODUCT SPECIFIED. N LOCATION PLAN N.7.5.(T 8. PERFORM ALL WORK IN ACCORDANCE WITH ACCEPTED CONSTRUCTION STANDARDS. ALL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH THE PLANS AND SPECIFICATIONS UNLESS A VARIANCE 15 APPROVED BY THE LANDLORD AND OR ARCHITECT. 9. ALL WORK PERFORMED SHALL BE IN STRICT COMPLIANCE WITH GOVERNING FEDERAL, STATE, AND LOCAL BUILDING CODE REQUIREMENTS, EXECUTED IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARDS AND SHALL CONFORM TO SPECIFIC REGULATIONS AS MANDATED BY THE OWNER, THE TENANT, AND THE ARCHITECT. 10. THESE DRAWINGS ARE THE PROPERTY OF WIEDRICK ARCHITECTURE INC. AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART. THESE DRAWINGS ARE TO BE USED FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT. yr �sMAI ' `- s' s R E', !1 PLANS EXA':o1i�33�`�— WIEDRICK ARCHITECTURE, INC. AA26001199 STATE OF FLORIDA REGISTERED ARCHITECT MATTHEW WIEDRICK REGISTRATION NUMBER: AR94511 6 w a 0 a 0 U w X Z 0 a C w Z w X w co iedrick a�saaao Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 > co Q J LL < � ry ig C ;3- J LLI It (If � _ QWN PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE DESCRIPTION 12/11/14 REV 01 - OWNER COMMENTS COVER SHEET MJW PROJECT #: 14022 G001 10/15/14 Existing Landscape Area CONDENSER PAD BY CONTRACTOR Fp +b Elec A�� Elec FE EXIT IGI LAB 120 DW table iL711 m hand I I mop I sink R i sink I I L---- J O fd WASH RM 12i I I I hand i eye I sink I wash � I I I I I ACCOUNTING 114 RAMP DN Elec F--F—T-7 I I I ! SHIPPING 122 DISPENSING 121 CASED OPENING r------------------�■ 3'-10%" 6'-0" 3'-6" 6'-OU 3'-6" 6'-0" rack rack rack rack LIFE SAFETY LEGEND • _ EXISTING AND/OR NEW RATED WALL ASSEMBLY. REFERENCE DETAIL 3/AI00 FOR UL INFORMATION. ® EXISTING AND NEW EMERGENCY EXIT LIGHT FIXTURE WITH ILLUMINATED FACE. EXIT 111111111111 PRIMARY TENANT/BUILDING EXIT. F.E. NEW WALL MOUNTED FIRE EXTINGUISHER ADJACENT OCCUPIED TENANT SUITE. NO WORK IN THIS AREA. r--®. IT LOR7 f] M L_ G D BREAK ROOM 124 1 ��---T� MEN LA5 1 I I I\ I 106 �I i 119 1------ - I 1 t TOILET 1 I VESTIBULE 1 101 i ---� L L 105 � ------- � 1 a� CONF. 1 II PHARMACY I�D ; ii 104 1 24X-,8 , 1 ® II 1 O 114X48 1 � EXISTING COLUMN TO 1 W--MAIN - COORDINATE 1 WITH OWNERS 1 24X48 ADMIN e ■ CONSTRUCTION ■ all REPRESENTATIVE ON 1®8 FINAL FINISH 1 PHARMACY 1 1 24X48 , SALES o 1 103 1 1 24X48 , 1 F.E. 1 COFFEE LOUNGE � 102 ----------- EXIT — — — — — — — — — — — - F.E. display I�I • EXIT EXISTING ENTRY IAI DOORS TO REMAIN Elec LIFE 5APET� PLAN 1 mp I- - - — - - Poo" Np* 41# t� r iftubovdfmt000aOn Earls Side >n€ UL 419 AND UL90(o N.T.S. ENLARGED 517E IMAGE. LIFE 5AFET ' NOTE5 1. THIS PLAN IS FOR GENERAL INFORMATION ONLY. PLEASE REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION 2. INTERIOR AND EXTERIOR ELEMENTS ARE EXISTING - CONTRACTOR TO ENSURE THAT FINISH FLOOR SURFACE ELEVATIONS ARE LESS THAN 1/2" DIFFERENCE AT ALL EXTERIOR AND INTERIOR DOOR LOCATIONS. 5COPE OF UJ0f--1;;N THIS IS AN ALTERATION TO THE EXISTING FIRST FLOOR TENANT SUITE LOCATED AT 3844 5TH AVE. ZEPHRHILLS FLORIDA 33542. THE AFFECTED AREA IS APPROXIMATELY 5950 SQUARE FEET. THE EXISTING SUITE IS APPROXIMATELY 5,550 SQUARE FEET. THE PURPOSE OF THIS ALTERATION IS TO BUILD -OUT THE SPACE INTO A FUNCTIONING MIXED USE (MERCANTILE AND BUSINESS) OCCUPANCY. THE SCOPE INCLUDES MODIFICATIONS TO THE EXISTING MECHANICAL AND ELECTRICAL SYSTEMS. THIS ALTERATION IS SUBMITTED USING THE PRESCRIPTIVE METHOD AS DEFINED IN THE FLORIDA BUILDING CODE - EXISTING BUILDING. THE FOLLOWING IS A BRIEF SUMMARY OF THE APPLICABLE CODE SECTIONS FROM THE 2010 FLORIDA BUILDING CODE - EXISTING BUILDING AND THE FLORIDA FIRE PREVENTION CODE: CHAPTER ONE - SCOPE AND ADMINISTRATION SECTION 101BA COMPLIANCE METHODS: REPAIRS, ALTERATIONS, ADDITIONS AND CHANGES OF OCCUPANCY COMPLYING WITH CHAPTER 3 OF THIS CODE IN BUILDINGS COMPLYINS WITH THE FLORIDA FIRE PREVENTION CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS OF THIS CODE. CHAPTER 3- PRESCRIPTIVE COMPLIANCE METHOD SECTION 303 ALTERATIONS: EXCEPT AS PROVIDED BY SECTION 3012 OR THIS SECTION, ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING: CODE, BUILDING FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NO LESS CONFORMING WITH THE PROVISIONS OF THE FLORIDA BUILDING CODE, BUILDING THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION. 2010 FLORIDA FLORIDA FIRE PREVENTION CODE CHAPTER 14 - MEAN OF EGRESS SECTION 14.2 EXIT ACCESS CORRIDORS: CORRIDORS USED AS EXIT ACCESS AND SERVING AN OCCUPANT LOAD EXCEEDING 30 SHALL BE SEPARATED FROM OTHER PARTS OF THE BUILDING BY WALLS HAVING NOT LESS THAN A 1-HOUR FIRE RESISTANCE RATING IN ACCORDANCE WITH SECTION 12.1 UNLESS OTHERWISE PERMITTED BY THE FOLLOWING: *L THIS REQUIREMENT SHALL NOT APPLY TO EXISTING: BUILDINGS PROVIDED THAT THE OCCUPANCY CLASSIFICATION DOES NOT CHANGE. 2. THIS REQUIREMENT SHALL NOT APPLY WHERE OTHERWISE PROVIDED IN CHAPTERS 11 THROUGH 43 OF NFPA 101:1.13.1 THE EXISTING SPACE 16 NOT SPRINKLED ALL FIRE ALARM WORK, INCLUDING CHANGES, ADDITIONS, RELOCATIONS, IMPROVEMENTS, AND/OR MODIFICATIONS TO THE FIRE ALARM SYSTEM MUST BE DONE PER NFPA -12 2001 EDITION BY A LICENSED FIRE ALARM CONTRACTOR WITH SEPARATE PERMIT AND PLANS PLEASE REFERENCE THE CODE SUMMARY (COVER SHEET) AND BUILDING DATA SECTIONS FOR ADDITIONAL INFORMATION UILIDINC; DATA BASED ON THE 2010 FBC AFFECTEDAREA.............................................................................. 5,950 SF OCCUPANCY TYPE ...........................................BUSINESS AND MERCANTILE CONSTRUCTION TYPE ..................................... EXISTING (V-B) - NO CHANGE SPRINKLERED.................................................................................... I ...... NO OCCUPANT LOAD - TABLE 1004.1.1 MERCANTILE - GRADE FLOOR AREAS (100 5QFT/30 GROSS) ................ 24 5U5INE55 - (3,335 SQFT/100 GROSS)........................................................ 34 KITCHEN (FRONT OF HOUSE) - (192 5QFT/200 GROSS) .............................. 1 STORAGE - (1135 5QFT/300 GROSS).......................................................... 4 TOTAL OCCUPANT LOAD..................................................................... : ..... 63 MEANS OF EGRESS TOTAL EGRESS WIDTH REQUIRED (63 OCCUPANTS X 0.2).........................1311 PROVIDED................................................................................................16011 MINIMUM NUMBER OF EXITS REQUIRED (FBC 1021.1).................................... 2 PROVIDED AND MARKED W/EMERGENCY LIGHT 51GNAGE ....................... 4 New Exit 'A' Width 0 3211 Existing Exit 'B' Width 66411 Existing Exit 'C' Width 6 3211 TOTAL 128" MAXIMUM TRAVEL DISTANCE ALLOWED - FBC TABLE 1016.1 MERCANTILE....................................................................................... 150 FT. BUSINESS............................................................................................200 FT. PROVIDED........................................................................................... 122 FT. PLEASE REFERENCE THE SCOPE OF WORK FOR ADDITIONAL INFORMATION W a 0 a 0 0 U In w a W m z 0 a 0 z Z X w 00 ied ick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 of a aj U') Q M LL }' Cn LO J � J Nl- m w M 2 PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE DESCRIPTION 12/11/14 REV 01 - OWNER COMMENTS LIFE SAFETY PLAN MJW PROJECT #: 14022 Al 00 10/15/14 m 13 13 Fj 14 vor �J EXISTING COLUMN TO REMAIN. PORTION OF EXISTING SLAB TO BE REMOVED AND REPLACED - REF. DETAIL 1/A601 n EXISTING STOREFRONT ASSEMBLY TO REMAIN ADJACENT TENANT SPACE N.I.C. ADJACENT TENANT SPACE N.I.C. 3'-4" TO BE REMOVED RE. NEW FLOOR PLa EXISTING COLUMN TO REMAIN EXISTING COLUMN TO REMAIN - COORDINATE WITH OWNERS CONSTRUCTION REPRESENTATIVE ON FINAL FINISH 1 12 1 1121 EXISTING ENTRANCE AND DISPLAY ASSEMBLY TO REMAIN ------N -- -------- D 1 ICL I T I Oil NOTE5 I. THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS REQUIRED TO COMPLETE DEMOLITION, REMOVAL AND RE -USE OF ALL ITEMS SHOWN ON DRAWINGS. 2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS AND EXISTING FINISHES THROUGHOUT ALL PHASES OF CONSTRUCTION. OCCUPIED AREAS INCLUDING PUBLIC AREAS ARE TO BE MAINTAINED BY THE GENERAL CONTRACTOR ANY DAMAGE TO "EXISTING -TO -REMAIN" CONSTRUCTION, MATERIALS OR EQUIPMENT MUST BE RESTORED TO THERE ORIGINAL CONDITION. 3. THE GENERAL CONTRACTOR SHALL ERECT ALL NECESSARY PLASTIC DROP CLOTH PARTITIONS TO PROTECT ADJACENT BUILDING PROPERTY WHILE DEMOLITION AND CONSTRUCTION IS IN PROGRESS. 4. ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES DAILY, EXCEPT ITEMS TO BE RE -USED OR RETURNED TO THE OWNER OR AS DIRECTED OTHERWISE. 5. THE GENERAL CONTRACTOR SHALL REMOVE ALL WALL CONDUITS, SWITCH PLATES, TELEPHONE OR ELECTRICAL WIRING OR EQUIPMENT, ETC. TO THE SOURCE AFTER WALL DEMOLITION. 6. REFER TO THE NEW FLOOR PLANS FOR VERIFICATION OF THE EXISTING CONSTRUCTION TO REMAIN AND EXTENT OF DEMOLITION. ALL EXISTING DOORS, FRAMES, HARDWARE, CABINETRY, AND OTHER BUILDING STANDARD COMPONENTS REMOVED DURING DEMOLITION AND NOT REUSED AS A PART OF THIS WORK ARE TO BE PROVIDED TO THE OWNER - COORDINATE WITH OWNER PRIOR TO DEMOLITION. 1. NOTIFY ARCHITECT IMMEDIATELY OF ANY PIPES, POSTS, DUCTWORK, SPRINKLER LINE OR MISCELLANEOUS EQUIPMENT CONFLICTS TO NEW PARTITION AND REFLECTED CEILING PLAN AFTER DEMOLITION IS COMPLETE. 8. ALL DOORS ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 9. ALL WINDOWS ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 0 DEMOLITION <E� NOTE5 1. EXISTING WALL AND/OR PORTION OF EXISTING WALL, STOREFRONT OR WINDOW TO BE REMOVED- SEE NEW PLAN. PATCH FLOOR AS REQUIRED FOR NEW FINISH MATERIAL. 2. EXISTING WALL FINISH MATERIAL AND FURRING TO BE REMOVED. ONCE NEW FLOOR PLAN. 3. EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO BE REMOVED. RETURN TO OMER IF REQUESTED - VERIFY WITH THE OWNERS CONSTRUCTION REPRESENTATIVE. 4. EXISTING FLOORING MATERIAL/FINISH TO 13E REMOVED - PATCH SLAB AS REQUIRED. REFERENCE NEW FLOOR PLAN FOR ADDITIONAL INFORMATION. 5. EXISTING CEILING ASSEMBLY AND ALL FIXTURES TO BE REMOVED. RETAIN LIGHT FIXTURES FOR RE -USE IN NEW CEILING ASSEMBLY -REF. ELEC DRAWINGS 6. ALL PLUMBING FIXTURES INCLUDING PARTITIONS TO BE REMOVED. CAP AND SEAL EXISTING PLUMBING LINES AS REQUIRED - REFERENCE NEW FLOOR PLAN AND PLUMBING PLANS FOR ADDITIONAL INFORMATION. I. EXISTING HOOD ASSEMBLY TO BE REMOVED. RETURN TO OWNER IF REQUESTED - VERIFY WITH THE OWNERS CONSTRUCTION REPRESENTATIVE. S. EXISTING STAIR AND MEZZANINE STORAGE AREA TO BE REMOVED. 9. EXISTING FIRE RATED WALL ASSEMBLY TO REMAIN- REPAIR/PATCH AS REQUIRED. ALL WORK TO COMPLY WITH UL REQUIREMENTS - REFERENCE LIFE SAFETY PLAN FOR ADDITIONAL INFORMATION. PREP WALL AS REQUIRED FOR NEW TENANT FINISHES. 10. REMOVE PORTION OF EXISTING SLAB AS REQUIRED FOR NEW PLUMBING - REF. PLUMBING PLANS FOR ADDITIONAL INFORMATION. 11. EXISTING MECHANICAL EQUIPMENT TO BE REMOVED - REF. MECHANICAL DRAWINGS 12. EXISTING WALL ASSEMBLY TO REMAIN - PATCH AND REPAIR AS REQUIRED. 13. THE SEVEN (1) EXISTING WINDOW ASSEMBLIES IN THE EXISTING EAST WALL ARE TO BE REMOVED - REF. NEW FLOOR PLAN FOR INFILL INFORMATION. 14. EXISTING PLASTIC WALL SHEATHING AT THE TOP OF THE EXISTING EXTERIOR WALL TO BE REMOVED - REFERENCE NEW FLOOR PLAN FOR NEW INFILL INFORMATION. IDEfiICL ITICN LEGEND EXISTING WALLS TO REMAIN — — — — — — — — — EXISTING WALL AND/OR PORTION OF EXISTING WALL, — — — — — — — — — STOREFRONT OR WINDOW TO BE REMOVED. EXISTING DOOR AND FRAME ASSEMBLY TO BE REMOVED. EXISTING TWO (2) HOUR FIRE RATED WALL ASSEMBLY. REFERENCE DETAIL 3/AIW FOR UL INFORMATION. NEW 3000 PSI CONC. W/FIBERGLASS REINFORCEMENT POUR BACK INCLUDE 03 BARS IS"LONG OW"O.C. (STAGGERED) EACH SIDE. DRILL AND ADHERE INTO EXISTING SLAB WITH 3-1/2" EMBEDMENT WITH HILTI HIT RE-500-SD ADHESIVE SYSTEM OR APPROVED EQUAL POUR TOP OF TRENCH FLUSH TO MATCH SURROUNDING AREA 10ML. VAPOR BARRIER OVER ENTIRE AREA EARTH FILL COMPACTED TO %% W/TERMITE-INSECT TREATMENT. *" 6 LU 0 Q of a 0 U H W 0 af Z a 0 w Z w _ w m Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z O N N QCY) M J a--+ 't U) J 't J of w"t M 2 Q� PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE DESCRIPTION 12/11/14 REV 01 - OWNER COMMENTS DEMOLITION PLAN DEMO FLOOR PLAN 3/16"=1'-0" SLAB INFILL DETAIL. 3/4" =1' -01I MJW PROJECT #: 14022 A101 10/15/14 Am ACOUSTIC CEILING CONTINUOUS METAL RUNNER CONTINUOUS METAL F4NER. ATTACH WITH I" RAMSET 300 DIAM NAILS'32"O.C. MIN SEALANT BOTH SIDES INTEIRIOIR PAIR I-I/2" = 1'-0" BRACE TO STRUCTURE ABOVE WITH KICKER STUDS s45 DEGREES IN ALTERNATING DIRECTIONS AS REQUIRED OPTION B 5/8" GWB EACH SIDE PROVIDE J-MOLD USE M.R. GM AT ALL TERMINATION FOR (LET AREAS OPTION 5-BOTH 6" or 3 V 20 GA METAL SIDES STUDS + 16" O.C. BASE AS SCHEDULED SEALANT BOTW SIDES FINISH FLOOR TITION -OPTIONS GENERAL CONFRUCTION NOTE5 1. REFER TO THIS SWEET FOR PARTITION TYPES AND SECTIONS. 2. PROVIDE (1) FIRE EXTINGUISHER PER 30M SQUARE FEET OF USABLE OCCUPIED SPACE OR 15 FEET OF TRAVEL. 3. VERIFY ALL STRUCTURAL, MECHANICAL, AND ELECTRICAL REQUIREMENTS AND COORDINATE REQUIRED CHANGES WITH OWNER PRIOR TO CONSTRUCTION. 4. VERIFY ALL DIMENSIONS SHOWN ON PLAN, DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT WITH ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 5. PROVIDE SUFFICIENT NUMBER OF 4'-0" X 8'-0" X 3/4" THICK FIRE RATED SHEETS OF PLYWOOD TO HOUSE PHONE/ DATA EQUIFMENT. PAINT TO MATCH WALLS. 6. ALIGNMENT OF DOOR HEADS AND OTHER CRITICAL HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT A CONSTANT LEVEL RELATIVE TO THE CEILING PLANE. 1. WET LOCATIONS (INCLUDING TOILET AREAS, MOP AND SINK AREAS, LAUNDRY, ETC) ARE TO HAVE WALLS CONSTRUCTED WITH MOISTURE RESISTANT GWB. 8. ALL EXPANSION JOINTS IN FIRE -RATED WALLS ARE TO MAINTAIN THE ASSEMBLY FIRE RATING. 9. ALL EXISTING LOCKS AND LATCHES USED TO PREVENT THE OPERATION OF AN EXIT MUST COMPLY WITH THE 2010 FBC SECTION 1008 - SPECIFICALLY SECTION 1008.183,1008.1.8.4 AND 1008.15 10. REPAIR ALL EXISTING WALLS AS REQUIRED TO RECEIVE PAINT COORDINATE FINAL FINISH SELECTION WITH OWNER 11. CASEWORK IS SHOWN FOR REFERENCE ONLY- CASEWORK IS NOT INCLUDED IN THIS SCOPE OF WORK, AND WILL BE PROVIDED UNDER A SEPARATE FUTURE CONTRACT WITH THE OWNER NEW LEGEND 000 DOOR NUMBER- REF. SHEET A600 FOO-0-1 ROOM NAME/NUMBER F.E. WALL MOUNTED 10 LB. 4A608C FIRE EXTINGUISHER NEW FULL HEIGHT WALL - REFERENCE PARTITION TYPES FOR ADDITIONAL INFORMATION EXISTING WALL ASSEMBLY TO REMAIN - V.IF. EXISTRING AND NEW FIRE RATED WALL ASSEMBLY - REFERENCE THE LIFE SAFETY SWEET FOR ADDITIONAL INFORMATION. ........................ ....................... .................... .... ....................... ........................ ....................... ........................ ........................ ADJACENT OCCUPIED TENANT SPACE - MERCANTILE. NO WORK IN THIS AREA. !a0 WINDOW SYMBOL - REF. A ---- SEE SECTIONS WALL /P A RT I I I ON T `rP 5 FOR EXTERIOR�SHLEYATIONS 1-NR FIRE RATING: 5/8" TYPE "X" GYPSW BOARD (EACH SIDE) ON 6' 20 GA METAL STUDS AT 16" O.C, ❑I EXTEND TO UNDERSIDE OF EXISTING ROOF DECK, FILL ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. PROVIDE MOISTURE -RESISTANT GYP BD IN WET AREAS (SEE GENERAL CONSTRUCTION NOTE 01 ABOVE). PROVIDE UL419 ASSEMBLY FOR 1-14R FIRE RATING. la NON -FIRE RATED WALL ASSEMBLY - REF. DETAIL 2/A102 -----........._.------------------------------------------------------------------------------------------ ------------------------------- ------------------- ------ 1-HR FIRE RATING: 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) ON 3-5/6" 20 GA. METAL STUDS AT 16" O.C, 2❑ EXTEND TO UNDERSIDE OF EXISTING ROOF DECK, FILL ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. PROVIDE UL U419 ASSEMBLY FOR 1-14R FIRE RATING. EXISTWs WALL ASSIMLY WI ❑3 EXISTING WALL ASSEMBLY TO REMAIN - V.IF. 5/8" GYPSUM BOARD (EACH SIDE) OVER 3-5/8" 20 GA MTL STUDS AT 16' O.C, -REF. DETAIL 2/A102 FILL CAVITY WITH SOUND ATTENUATION BATTS. STAGGER STUDS AS REQUIRED IN BATHROOM WET WALL - REF. DETAIL 1/A400. USE MOISTURE RESISTANT GWB IN ALL BATHROOMS AND OTHER WET LOCATIONS. EXISTING WALL ASSEMBLY V.I. PROVIDE 5/0" GYP. BD. OVER 1-1/2" HAT CHANNELS AT 16" O.C. EXTEND INTERIOR MATERIALS (ON EXTERIOR WALLS) TO EXISTING ROOF DECK ABOVE. PROVIDE 5/8" MOISTURE RESISTANT GYP BD IN WET AREAS (SEE GENERAL CONSTRUCTION NOTE 01 ABOVE). PROVIDE LINE ITEM FOR RIGID INSULATION BOARD - VERIFY WITH TENANTS CONSTRUCTION REPRESENTATIVE. ----------------------------------------------------------------------- _------------------------------- -------- --.... _.................. .... --...... ..... --------------- ---------- - - 5/8" GYPSUM BOARD (INTERIOR SIDE) OVER 3-5/8" EXISTING WALL ASSEMaLY V.I. 20 GA MTL STUDS AT 16" O.G, -REF. DETAIL 2/AI02 FILL CAVITY WITH SOUND ATTENUATION BATTS. USE MOISTURE RESISTANT GWB IN ALL BATHROOMS AND OTHER WET LOCATIONS. i Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z O Q LU N Nt m M ILL � J � J 00 >- M m W J W 0 N a c� a 0 U W L W UjW 0 PROJECT ADDRESS: Z 38444 5TH AVE. PS ZEPHYRHILLS, FL 33542 W x W m J C 0 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. z 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE DESCRIPTION 12/11/14 REV 01 - OWNER COMMENTS ALTERED FLOOR PLAN MJW PROJECT #: 14022 Al 02 10/15/14 ALTERED FLOOR PLAN N REFLECTED CEILING PLAN NOTES L CONTRACTOR MUST VISIT THE PREMISES TO CONFIRM CONDITIONS PRIOR TO SUBMITTNG A COST QUOTATION. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NF-ORMATION. 2. PROVIDE EMERGENCY LIGHTING, STROBES, ALARMS, FIRE PULLS AND SMOKE DETECTORS AS REQUIRED BY CODE. 3. NOTIFY ARCHITECT IMMEDIATELY OF ANY CLEARANCE CONFLICTS WITH LIGHT FIXTURES DUE TO ITEMS (DUCTWORK, SPRINKLER LINES, ETC) ABOVE CEILING. 3. 2X4 ACOUSTICAL CEILI1 G TILE AND GRID BY ARMSTRONG OR EQUAL: • TYPE: DUNE WITH SAV GRID BEVELED TEGULAR EDGE • CLASS A. • SEE CEILING PLANS FOR ADDITIONAL INFORMATION • ALL CEILINGS TO BE 10 FT AFF UNLESS NOTED OTHERWISE. 4. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. fREFL CT D CEILING FLAN LEGEND REFERENCE ELECTRICAL DRAWNGS FOR SPECIFIC TYPES TO BE USED. ® 2 X 4 FLUORESCENT Q RECESSED COMPACT FLUORESCENT DOWNLIGHT SURFACE MOUNTED TRACK LIGHT ® EXIT LIGHT (PROVIDE DIRECTIONAL ARROWS WHERE NOT LOCATED DIRECTLY ABOVE EXIT) LJ EMERGENCY BATTERY PACK LIGHT FIXTURE. ® SUPPLY AIR GRILLE -SEE MECHANICAL DWG'S RETURN AIR OR TRANSFER GRILLE -SEE MECHANICAL OWG'S EXHAUST FAN -SEE MECHANICAL DWG'S SUSPENDED ACOUSTICAL CEILING GRID - SEE NOTE 03 VINYL FACED CEILING TILES 1/2” GWB CEILING OVER 3-5/8" 20" MTL. STUDS 16"O.C. CEILING HEIGHT INDICATOR 2' CEILING FLAN_ 3/6.Pm EXISTING ROOF STRUCTURE ABOVE V.I.F. OPTIONAL CROWN MOLDING PAINTED GM -PAINTED OVER 3-5/8" MTL. STUD FRAMING s 16110.C. DOWN LIGHT REF, ELEC DRAWINGS FIRE RATED WALL ASSEMBLY -REF PARTITION TYPES DETAIL 10'4" AFF. BOT.OF A.T. GE IL ING jk95-2" AFF. N�JI50T.OF SOFFIT Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 z p N ai QCY) M J LL � �--" � Co J � J 2(y) N PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE DESCRIPTION 12/14/14 REV 01 - OWNER CHANGES CEILING PLAN MJW PROJECT #: 14022 Al 03 10/15/14 ED RAMP Existing Landscape Area DN SHIPPINCx 122 ® O ■ INFILL TOP OF EXISTING WALL ASSEMBLY WITH NEW 20 GA 6" METAL STUDS e16"O.G. INTERIOR: EXTEND GWB TO UNDERSIDE OF EXISTING ROOF ASSEMBLY- 4-FILL WALL CAVITY WITH R-IS INSULATION. EXTERIOR: NEW BREAK METAL WALL PANEL OVER (2) LAYERS 150 FELT MECHANICALLY FASTENED TO 5/8" MIN EXTERIOR GRADE SHEATHING OVER 20 GA 6" METAL STUDS ,16" O.C. IT Q 123 120 OPENING II A�oo DW table — I 12" a 0 1 haM I mop .-0 oink 3 I I oink fd WASH RM 3'-103/" 6'-0" 3'-6" 6'-0" 3'-6" 6'-0" 12i 121 O rack rack hand eye oink I wash I I I rack rack ACCOUNTING 114 REFERENCE ELECTRICAL DRAWINGS FOR SYSTEMS ADMIN FURNITURE LAYOUT - ALL FURNITURE WILL BE PROVIDED 108 BY THE OWNER D15PENSING 121 CASED 123 IT STORAGE 125 � 125 0Q 0 BREAK ROOM 124 = I Tn124 qF I r — PEEN — -� - ' I i I TOILET VESTIBULE — 107 I0 — WOMEN EXISTING COLUMN 111A 1118 TO REMAIN. O O O � / CONK 0 FURNITURE PLAN 3/16"= I'-0" :\ LAB 11-5 r Ir — I : 1 124X48 I 124X48 I e e EXISTNG COLUMN TO REMAIN - COORDINATE a WITH OWNERS 124X48 CONSTRUCTION REPRESENTATIVE ON I FINAL FINISH PHARMACY 124X48 SALES ' 103 - � 24X48 102 COFFEE LOUNGE' all MIN dioplay CHECKOUT/SALES COUNTER TO BE PROVIDED BY G.C. COORDINATE FINAL DESIGN WITH OWNERS CONSTRUCTION REPRESENTATIVE. FINAL DESIGN MUST COMPLY WITH ALL 2010 FBC REQUIREMENTS. EXISTING ENTRY -- DOORS TO REMAIN 33'-M" PROVIDE NEW ROLL DOWN HURRICANE/SECURITY SHUTTER ASSEMBLY N v, . FURNITURE SHOIIN FOR REFERENCE ONLY - FINAL SELECTION OF FURNITURE, CASE WORK TO BE COORNATED WITH THE OWNERS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND/OR INSTALLATION GENERAL C V NFRUCT I ON NOTE5 I. REFER TO THIS SHEET FOR PARTITION TYPES AND SECTIONS, 2. PROVIDE (1) FIRE EXTINGUISHER PER 30M SQUARE FEET OF USABLE OCCUPIED SPACE OR 15 FEET OF TRAVEL. 3. VERIFY ALL STRUCTURAL, MECHANICAL, AND ELECTRICAL REQUIREMENTS AND COORDINATE REQUIRED CHANGES WITH OWNER PRIOR TO CONSTRUCTION. 4. VERIFY ALL DIMENSIONS SHOWN ON PLAN, DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT WITH ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 5. PROVIDE SUFFICIENT NUMBER OF 4'-0" X V-0" X 3/4" THICK FIRE RATED SHEETS OF PLYWOOD TO HOUSE PHONE/ DATA EQUIPMENT. PANT TO MATCH WALLS. 6. ALIGNMENT OF DOOR HEADS AND OTHER CRITICAL HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT A CONSTANT LEVEL RELATIVE TO THE CEILING PLANE. Z. WET LOCATIONS (INCLUDNG TOILET AREAS, MOP AND SINK AREAS, LAUNDRY, ETC) ARE TO HAVE WALLS CONSTRUCTED WITH MOISTURE RESISTANT GWB. S. ALL EXPANSION JOINTS IN FIRE -RATED WALLS ARE TO MAINTAIN THE ASSEMBLY FIRE RATING. 9, ALL EXISTING LOCKS AND LATCHES USED TO PREVENT THE OPERATION OF AN EXIT MUST COMPLY WITH THE 2010 FBC SECTION 1008 - SPECIFICALLY SECTION 1008.IB3,1008.IB.4 AND 1008.15 10. REPAIR ALL EXISTING WALLS AS REQUIRED TO RECEIVE PAINT COORDINATE FINAL FINISH SELECTION WITH OWNER ll. CASEWORK IS SHOWN FOR REFERENCE ONLY- CASEWORK IS NOT INCLUDED IN THIS SCOPE OF WORK, AND WILL BE PROVIDED UNDER A SEPARATE FUTURE CONTRACT WITH THE OWNER NEW LEGEND 000 DOOR NUMBER- REF. SHEET A600 000 ROOM NAMEW15ER F.E. WALL MOUNTED 10 LB. 4A605C FIRE EXTINGUISHER NEW FULL HEIGHT WALL - REFERENCE PARTITION TYPES FOR ADDITIONAL INFORMATION EXISTING WALL ASSEMBLY TO REMAIN - V.IF. EXISTRNG AND NEW FIRE RATED WALL ASSEMBLY - REFERENCE THE LIFE SAFETY SHEET FOR ADDITIONAL INFORMATION. ADJACENT OCCUPIED TENANT SPACE - MERCANTILE. NO WORK IN THIS AREA. 00 WINDOW SYMBOL - REF. A---- < > UJAL L /FAIRT I T I ON TYP 5 FOR EXTERIOR FAINIISHLEVATIONS I-HR FIRE RATING: 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) ON 6" 20 GA METAL STUDS AT 16" O.C., ❑I EXTEND TO UNDERSIDE OF EXISTING ROOF DECK, FILL ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. PROVIDE MOISTURE -RESISTANT GYP BD IN WET AREAS (SEE ORAL CONSTRUCTION NOTE 01 ABOVE). PROVIDE LL419 ASSEMBLY FOR 1-HR FIRE RATING. la NON -FIRE RATED WALL ASSEMBLY - REF. DETAIL 2/AI02 1-HR FIRE RATING: 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) ON 3-5/8" 20 GA. METAL STUDS AT 16" O.C., ❑2 EXTEND TO UNDERSIDE OF EXISTING ROOF DECK, FILL ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. PROVIDE UL U415 ASSEMBLY FOR I-HR FIRE RATING. EXISTING WALL ASSEMBLY V.I. EXISTING WALL ASSEMBLY TO REMAIN - V.IF. 5/8" GYPSUM BOARD (EACH SIDE) OVER 3-5/8" a20 GA MTL STUDS AT 16" O.C, -REF. DETAIL 2/AI02 FILL CAVITY WITH SOUND ATTENUATION BATTS. STAGGER STUDS AS REQUIRED IN BATHROOM WET WALL - REF. DETAIL I/A400. USE MOISTURE RESISTANT GWB IN ALL BATHROOMS AND OTHER WET LOCATIONS, EXISTING WALL ASSEMBLY V.IF. PROVIDE 5/8" GYP. BD. OVER 1-1/2" HAT CHANNELS AT 16" O.G. EXTEND INTERIOR MATERIALS (ON EXTERIOR WALLS) TO EXISTING ROOF DECK ABOVE. PROVIDE 5/8' MOISTURE RESISTANT GYP BD IN WET AREAS (SEE GENERAL CONSTRUCTION NOTE 01 ABOVE). PROVIDE LINE ITEM FOR RIGID INSULATION BOARD - VERIFY WITH TENANTS CONSTRUCTION REPRESENTATIVE. -- --- - --- - --- -- - - -- - - --- ---- - -- -- - --- -- - 5/8" GYPSUM BOARD INTERIOR SIDE) OVER 3-5/6" EXISTMG WALL ASSEMBLY V.Ir-. 20 GA MTL STUDS AT 16" O.C, -REF. DETAIL 2/AI02 FILL 51 CAVITY WITH SOUND ATTENUATION BATTS. USE MOISTURE RESISTANT GWWB IN ALL BATHROOMS AND OTHER LET LOCATIONS. i� Wiledrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 � M M J J _J qt _ 00 >- ch � W W a 0 N a 9 < 0- 0 0 Cn w w z n- PROJECT ADDRESS: loll Z 38444 5TH AVE. ZEPHYRHILLS, FL 33542 W w m CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE DESCRIPTION 124444 REV 01 - OWNER CHANGES FURNITURE PLAN MJW PROJECT #: 14022 Al 04 10/15/14 0 AM 8 — m =— o MEN o up-, WOMEN o n 61� 61N MEN - H.C. Jb U_ UJOMEN - H.C. all NO SMOKING SIGNS SKINS ARE TO BE TWO TONED WaAMM V WRITE SYMBOLS AND LEM110 G. LEITERM1Cs IS ALSO PROVIDED N BRAIIRM O MR"Wa MOW LOLOCATOR I W'�00M - " '� NO SMOKING IRFROOM 5IGNAGE 3"=1'-0" oc 8 LL n 2 u ELEVATION A ELEVATION B ELEVATION C 1'-6" 61_61l 61_611 3 4 2 II MAX HT. 3'-011 0 ? N - 1NWLATE 11_6�I PIPES Iwl PUBIC BATHROOM ELEVATION6 3/8" =1' -0" EXISTING ROOF ASSEMBLY V.I.F. CONT. SEALANT NEW METAL WALL PANEL OVER (2) LAYERS 150 FELT MECHANICALLY FASTENED TO 5/8" MIN EXTERIOR GRADE SHEATHING OVER 20 GA 6" METAL STUDS sib" O.C. - STAGGER STUDS AS REQUIRED FOR INTERIOR AND EXTERIOR FINISH ALIGNMENT. CONT. SEALANT EXISTING WALL ASSEMBLY VJR THIN -LINE METAL WALL PANEL 5Y 5ERRIDGE OR EQJAL. FL14(ob%S FINAL SELECTION AND COLOR TO 5E VERIFIED 5Y THE OWNER PRIOR TO PURCHASE AND/OR INSTALLATION w w- _gL NEW CEILING ASSEMBLY. _ SEE PLAN DETAIL I" = I ' -0" 9 VINYL COVE BASE -TYP EXISTING METAL ROOF SLY V.I.F. [WILL TOP OF EXISTING WALL ASSEMBLY WITH NEW 20 GA 6" METAL STUDS 416"O.C. EXTEND NEW GM (REF. WALL TYPE 5) TO UNDERSIDE OF EXISTING ROOF SLY- IPFILL WALL CAVITY WITH R-19 INSULATION. CEILING ASSEMBLY AS SCHEDULED VINYL COA BASE -TYP CLEARANCE INSULATE PIPES TOILET A C C 5 5 0 fR� 5CHEDULE ( APPROVED ALTERNATES ARE ACCEPTABLE) KE1-o DESCRIPTION MANUFACTURER/MODEL REMARKS 5RADLEY - MODEL 508 IN STANDARD STALL SURFACE MOUNT- INCLUDE THEFT RESISTANT SPINDLE (-52) 1 TOILET TISSUE DISPENSER PROVIDE 5LOCKING AT FRAME WALLS 5RADLEY - MODEL 523 DOU5LE ROLL IN ACCESSIBLE SURFACE MOUNT- INCLUDE THEFT RESISTANT SPINDLE (-52) IA TOILET TISSUE DISPENSER STALL PROVIDE 5LOCKING AT FRAME WALLS GRAB BARS 5RADLEY - 800 SERIES -MOUNTING HEAVY DUTY SERIES 36" AND 42" LONG BARS 2 i 812 - STAINLESS STEEL 1 1/2" DIA. PROVIDE BLOCKING AT FRAME WALLS 3 18"X30" MIRROR 5RADLEY - 100 SERIES - MODEL 140-1830 ADA LIANT DB LOCKINCs At FRAME WALLS 4 SOAP DISPENSER 5RADLEY - MODEL 6562 (wall mounted) ADA COMPLIANT PROVIDE BLOCKING AT FRAME WALLS 5 TOWEL DISPENSER 5RADLEY - MODEL 2442-10 (SEMI RECESSED) ADA COMPLIANT PROVIDE BLOCKING AT FRAME WALLS 6 1 TOILET fROCM NOTE5. 1. TOILET ROOM SIGNAGE: 2. FLOORS SHALL HAVE A SMOOTH, HARD, NONA5SOR5ENT SURFACE PROVIDE THE FOLLOWING ADA-APPROVED SIGNAGE AT EACH THAT EXTENDS UPWARD ONTO THE WALLS AT LEAST 6 INCHES. TOILET ROOM AS MANUR 5Y SCOTT SIGN SYSTEMS, SARASOTA, FL. (I-800-231-S441 EXT. 208), OR EQUAL AS APPROVED 5Y 3. WALLS WITHIN TWO (2) FEET OF URINALS AND WATER CLOSETS SHALL ARCHITECT: HAVE A SMOOTH, HARD, NONA5SOR5ENT SURFACE, TO A HEIGHT OF OMEN" AND "WOMEN" W/ INTERNATIONAL HANDICAP SYMBOL. FOUR (4) FEET A50VE THE FLOOR, AND EXCEPT FOR STRUCTURAL •WALL -MOUNT AT LATCH SIDE OF DOOR ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL 5E OF A *INSTALL W/ HIGH BOND TAPE - MOUNT AT 60" FROM FINISH FLOOR TYPE THAT 15 NOT ADVERSELY AFFECTED 5Y MOISTURE. TO CENTERLINE OF SIGN. COORDINATE ALL MILLWORK AND FINISHES WITH THE TENANTS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND/OR INSTALLATION ENLARGE[) PLAN Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 N ai CM Q J Lo LL ry � J 00 M 20- W J W a N 0 a a a 0 U F 0) W Z) 0 W Z PROJECT ADDRESS: z 38444 5TH AVE. ZEPHYRHILLS, FL 33542 w _ J Q CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION 11111 12/14/141 REV 01 - OWNER CHANGES ENLARGEDPLANS MJW PROJECT #: 14022 A400 10/15/14 ED 5 A LL; v> e }� VERIFY HEIGHT I WINDOW TYPE NOTES: I. COORDINATE WITH TENANTS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND OR INSTALLATION. VERIFY FRAME, COLOR, AND FINISH. OTEMPERED GLASS INTERIOR ELEVATION 3/8"=1'-0" • MIC v SHELF ONLY ADJUSTABLE SHELVES ON RECESSED STDSJCLIPS -CABINET PULL "STANLEY" O uu 4484 ALUM. OR EQUAL _ N -OPTIONAL MICROVE SHELF - COORDINATE ELECTRICAL z RECEPTACLE LOCATION FOR mic ALL INTERIORS OF UPPER E LOWER CABINETS LNED WITH WHITE MELAMINE Q COORDINATE WALL FINISH WITH OWNERS CONSTRUCTION e REPRESENTATIVE PLASTIC LAMINATE ON 2 k' LAYERS 3/4" PLYWOOD i ALL EXPOSED SURFACES t RETURNS TO BE PLASTIC LAMINATE ON 3/4" PLYWD. A `) N a 0 VINYL BASE v ALIGN WINDOW HEADS WITH DOOR FRAMES a a LL; v> a a }� VERIFY HEIGHT e B WINDOW TYPE MILLWORK DRAWMW ARE FOR DESIGN INTENT ONLY. G.C. IS REQUIRED TO SUBMIT SHOP DRAWINGS, WITH FIELD VERIFICATION MEASUREMENTS FOR APPROVAL PRIOR TO FABRICATION. COORDINATE ALL MILLWORK AND FINISHES WITH THE TENANTS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND/OR INSTALLATION 4" LAMINATE COUNTERTOP W/ 4"H CONT. BACKSPLASH LAMINATE FACE INSULATE PIPES FOR ADA PROTECTION 0 N - INTEGRAL KICK FOR ADA ACCESSIBILITY TO BE AT ALL SINK LOCATIONS VINYL BASE: r rp! PHAIRMACY OPEN TO BEYOND lV I ADA COUNTER G PHAiRh1AG:Y WINDOW LAMINATE COUNTERTOP UJ/ 4"H CONT. BACKSPLASH LAMINATE FACE SEE FIN. 804ED. T�CO LNDERR SUPPORTS SIZE AND SPACE AS REQUIRED TO ACCOMMODATE EQUIFMT. PROVIDED DY OMER 3 IL 111LLUJORK NCTE5 I. ALL MILLWORK SHOWN ON DRAWINGS TO BE IN ACCORDANCE WITH AWI STANDARDS FOR CUSTOM GRADE. 2. ALL MILLWORK TO BE 3/4' PLYWOOD, FRAMELESS CONSTRUCTION WITH ALL EXPOSED SURFACES AND RETURNS TO BE PLASTIC LAMINATE, UNLESS OTHERWISE NOTED. 3. ALL INTERIOR OF CABINETS AND DRAWERS TO BE WHITE MELAMINE LINER 4. ALL HARDWARE TO BE AS FOLLOWS: • 4' WIRE PULLS WITH BRUSHED SATIN FINISH MOUNTED HORIZONTALLY. • ALL DRAWER GLIDES TO BE HEAVY DUTY, FULL EXTENSION GLIDES WITH STEEL BALL -BEARINGS. • CONCEALED HINGES. • CLEAR RUBBER BUMPERS MOUNTED AT ALL INSIDE FACES OF ALL DRAWERS AND DOORS. • ALL SHELVING TO BE ON ADJUSTABLE RECESSED STANDARDS AND CLIPS • TILT DRAWERS AT SINK LOCATIONS. 5. ALL SINK LOCATIONS TO HAVE INTEGRAL TOE KICK BUILT IN TO CABINET DOORS FOR ADA COMPLIANCE. INSULATE PIPES AS REQUIRED. 6. ALL SINKS TO BE STAINLESS STEEL WITH GOOSENECK FAUCET, HOT AND COLD WATER WITH LEVER HANDLES 1. MIU-II10RK DRAWINGS ARE FOR M04 INTENT ONLY. GEC. IS REQUIRED TO SUBMIT SHOP DRAWNGS, WITH FIELD VERIFICATION MEAM43WO FOR APPROVAL PRIOR TO FABRICATION. S. ALL OUTLETS ABOVE COUNTERTOPS TO BE MOUNTED AT 44" AFF_ GRI. OUTLETS NEAR WET AREAS. OUTLETS COVER -PLATES TO BE FLUSH WITH FACE OF FULL HEIGHT BACK SPLASHES. MILLWORK DRAWINGS ARE FOR DESIGN INTENT ONLY. G.C. IS REQUIRED TO SUBMIT SHOP DRAWINGS, WITH FIELD VERIFICATION MEASUREMENTS FOR APPROVAL PRIOR TO FABRICATION. COORDINATE ALL MILLWORK AND FINISHES WITH THE TENANTS CONSTRUCTION REPRESENTATIVE PRIOR TO PURCHASE AND/OR INSTALLATION 3'-9" 10'-Gh" 6 W 0 a a 0 F W c3 W m z a O W z It I_ W M w m a Wiedfjc� Architecture, I i WIEDRICK ARCHITECTURE INC� . AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 4- Z O CN aj CM > CM Q J LL C J 't _J qqj- 2 NT Of 00 >_ CY) 2 w N PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION 12/14/14 REV 01 - OWNER CHANGES DETAILS SECTION SECTION SECTION INTERIOR ELEVATION MJW PROJECT #: 14022 A401 10/15/ 4 L ROOM FIN15H 5CHEDULE FIN15H NOTE5 DOOR NOTE5 DOOR 5CHEDULE a>` ROOM FLOOR BASE WALLS WALL F=INISW CEILING OT14ER REMARKS L COORDINATE AND VERIFY ALL FINISHES WITH OWNER'S CONSTRUCTION REPRESENTATIVE PRIOR L COORDINATE WITH OWER'S CONSTRCTION REPRESENTATIVE ON FINAL SELECTION OF ALL DOOR DOOR FRAME GENERAL TO FW C44AM AND/OR INSTALLATION OF ANY MATERIAL DOORS, FINISH AND HARDWARE PRIOR TO RP44W AND/OR INSTALLATION DIMENSIONS HOW REMARyCS/NOTES NO. TY LOCATION WIDTH HEIGHT THICK. PE MAT'L FIN. MAT'L FIN SILL JAMB HEAD SET 2. AT ALL DRYWALL: TAPE, FILL AND SAND EXPOSED DRYWALL JOINTS AND SURFACES TO 2. PROVIDE SILENCERS N ALL INTERIOR HOLLOW METAL FRAMES.•w'�' PRODUCE A SMOOTH W-TEXTUIIZED SURFACE, PRIED AND READY FOR SPECIFIED FINISH. 4 Od' PEATI$R COATS ONTO ADJOINING &*ACES SO THAT CAMBER IS MAXIMUM 11132 NCH. ALL WORK 3. HARDWARE SCHEDULE PROVIDED FOR PRICING AND DIPPING PURPOSES ONLY. CONTRACTOR SHALL BE N ACCORDANCE WITH GYPSUM ASSOCIATION SPECIFICATION GA 216. FINISH AS TO VERIFY FINAL SELECTION OF ALL DOOR HARDWARE WITH THE OWNERS CONSTRUCTION PRIOR !L W SPECIFIED. t0 MAW44AM AND/OR INSTALLATION. � 102 COFFEE LOUNGE CWD V-0" 1'-0" 1-3/4" C X STBD. HM.IN TBD. - 1/A600 VA600 11W-4 FIRE RATED DOOR AND FRAME ASSEMBLY r�` SIM 3. ALL EXPOSED CONCRETE OR MASONRY WALL SURFACES SHALL BE CLEANED, SEALED AND I/A"O VA600 LU Z -. WALLS PANTED. 103 PHARMACY SALES EXISthNG EXISTING SM =1 104 PWAAMACY V-0" i'-0" 1-3/4" C SCWD T.5D. HM. TSD. — VA600 VA600 HW-4 SPECIALITY DOOR - COORDINATE WITH OWNERS IK � 4. USE MOISTURE RESISTANT GILB AT ALL WET LOCATIONS AND USE DENSSHIELD BEHIND ALL m U SIM CONSTRUCTION REPRESENTATIVE U � E w `� w m 4 O Ll 4 CERAMIC WALL tU.E s 105 WOMENS BATHROOM 3'-0" 1'-0" 1-3/4° G SCUUD TBD. HM. TBD. - VA600 UA600 HIW-2 a m Q �i F- $ 0 uU� ` 1 5. ALL INTERIOR TRIM PANT TO BE SEMI GLOSS - VERIFY ALL COLORS WITH THE OWNER'S I SM Ll U U U u E CONSTRUCTION REFnESENTATIVE PRIOR t0 FURCHIASE AND/OR INSTALLATION W& MENS BATHROOM 3'-0" -1'-0" 1-3/4" C SCUID t.SD. W.M. TBD. - 1/A600 UA600 HW-2 a SIM '� 4 LL }J 6. ROOM SIGNAGE PACKAGE: PROVDE FOR AEA -APPROVED SIGN AGE AT EACH ROOM AS MIARF. NO. NAME �y U O 4 lil ul C BY SCOTT SIGN SYSTEMS, SARASOTA, FL 11-WO-23i-U41 ER. 208), OR EQUAL AS 108A ADMIN 3'-0" i'-0" I-3/4" D MTL. T.S.D. HM TBD. I/A601 3/A601 I/A601 HW-7 PROVIDE CLOSED DOOR SLLEEP, ADA THRESHOLD �i U U �t tr U 2= U U w APPROVED BY ARCHITECT: ADA APPLICi>IlE SI&a FNAL SELECTION TO BE MADE BY OW ER SIM METAL RAN GUARD. PROVIDE WEATHER-STRIPS PRIOR TO PURCHASE AND OR INSTALLATION. COORDINATE WITH BUILDING INFORMATION ON FIRST F t LOCATION OF WITH �� FOSS OMITTED 3'-0" 1'-0" I-3/4° G iE SCU)D TBD. HM.iE TBD. VA600 UA�600 HW-I FIRE RATED DOOR AND FI?,4ME ASSEMBLY ,. BOARD IRS FLOOR- VERIFY MODEL L 50APO OWNER SIM 101 SALES • • • • • EPDXY PAINT I. PROVIDE FLOORING TRANSITION STRIPS AS REQUIRED - COMPLY WITH ALL ADA REQUIREMENTS, M OMITTED V-0" 1'-0" 1-3/4" C SCWD TBD. W.M. TBD. - VA600 VA600 HW-4 SIM 102 COFFEE LOUNGE • • • • • 8. CONSTRUCTIONPROVIDE OCOR ERS ARDS At ALL EXPOSED GYP BD EDGES - COORDINATE WITH OWNE" 110 OMITTED 3'-0" i'-0" 1-3/4" C )( SCUA TBA HM.)( TBD. - UA600 VA600 HW-4 FIRE RATED DOOR AND M AME ASSEMBLY W Sim 103 PHARMACY SALES • • • • • IIIA CONFERENCE ROOM ' 3'-0" 1'-0" 1-3/4" C IN SCWD TBD. HM if TBD. - VA600 VA600 HW-4 FIRE RATED DOOR AND FRAME ASWIDLY aim 104 PHAR1ACY • • • • • EPDXY PANT O ills CONFERENCE ROOM V-0" 1'-0" 1-3/4" C 3f SCWD TBD. HM.)( TBD. - I/A600 VA600 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY ed SIM �5 WOMEtJfi BATHROOM • • • • • EPDXY PAIN 112 OMITTED 3'-0" 1'-0" 1-3/4" C SCWD TBD. H11. TBD. - I/A600 VA600 HW-4 Sim 106 MEW BATHR001'1 • • • • • EPDXY PAINT 113 OMITTED 3'-0" '►'-0" 1-3/4° C SCWD TBD. HM. TBD. - VA�600 VA600 F#U-3 Sim 101 TOILET VESTIBULE • • • • a 114 ACCOWTNG 3'-0" 1'-0" 1-3/4" Cif SCWD TAD. HM.)( TBD. — VAb00 VA600 00 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY I" ADMIN • • • • • BARD WAREGR0UP5 e 116 OMITTED 3'-0" 11.0" 1-3/4" C X ALLM TBD. HM.X Tim— VA600 VA600 HD-4 FIRE RATED DOOR AND FRAME ASSEMBLY 10% OMITTED • • • • • HW-1 SCHILAGE EXTRA HEAVY DUTY COMMERCIAL ND -SERIES HW-4 SCHLAGE EXTRA HEAVY DUTY COMMERCIAL ND -SERIES HW-1 SCHLAGE EXTRA HEAVY DUTY COMMERCIAL ND -SERIES 'NDUD Ill OMITTED 3'-0" 1'-0" 1-3/4" C X SCUD TBD. HMif TBD. — I/A600 VA600 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY 4NDW6, A451 Fli, PASSAGE LATCH FUNCTION, RHODES WSOPD, ANSI F82, ENTRANCE/OFFICE LOCK R NCTION, ELECTRICALLY LOCKED (FAIL SAFE), RHODES ADA LEVER a Sim Ito OMITTED • • • • • ADA LEVER HANDLES, %26 SATN CHROME FINISH. BOTH RHODES ADA LEVER HANDLES, %26 SATIN CHROME H6ANDLE$ %26 SATIN CHROME FINISH. 118 OMITTED 3'-0" 1'-0" 1-3/4" C SCUD TBD. HM. TBD. - VA600 UA600 HW-i LEVERS ALWAYS UNLOCKED. CLOSER, LENCERS SI, WALL FINISH. PUSH-BUTTON LOCKING - PUSH-5UITON LOCKS PROVIDE KEYLESS ENTRY (TRINE ADJUSTA5LE STRIKE 2012, SAT' SM 111 CONFERENCE ROOM OR FLOOR STOP. OUTSIDE LEVER UNTIL UNLOCKED WITH KEY OR 5Y ALUMIIN,M FINISH, FAIL SAFE' CHARACTERiSTIGS OR EQIUOL) 119A LAB 3'-0" 1'-0" I-3/4° G iE SCWD TBD. HM.If TBD. - VA600 VA600 HW-4 FIRE RATED DOOR AND FRAI"E ,48SEMIBLY • • • • • • ROTATING INSIDE LEVER SILENCED WALL STOP OR LEVER FROM ADMIN IN ALWAYS UNLOCKEDSM 112 OMITTED • • • • • a FLOOR STOP As APPLICABLE. OBTAINED THR204 KEYLESS ER FROM EXTERIOR SENTRY :1I�Es8 ACCESS Is 1195 LAB 3 -0 1-0 1-3/4 — HW-2 SCHLAGE EXTRA WAVY DUTY COMMERCIAL ND -SERIES � � " " C SCWD TAD. HM TBD. — VA600 UA600 HW-4 PROVIDE CLOSER, SILENCERS, DOOR STOPS / I6 HKH X 34aim 113 OMITTED • • • • • W408, ANSI F16, BATH PRIVACY LOCK RNCTION, HW-5 ENTRY/EXIt ASSEMBLY BY ALUMINUM STOREFRONT AIDE STAINLESS STEEL KICKPLATE ON PUSH SIDE OF DOOR 1, ,1 RHODE$ ADA LEVER HANDLES, %26 SATN CHROME MANUFACTURER, ADA PUSHPJLL HANDLES, TURN -BUTTON 119C OMITTED 3 -0 1-0 1-3/4 C X SCWD TBD. HM.)( TBD. 1/A600 VA600 HW-4 FIRE RATED DOOR AND FRAME ASSEMBLY FINISH. PUSH-BUTTCN LOCKING - CAN BE OPENED FROM . MORTISE LOCK, CLOSER WEATHERSTRIPS, ADA aimITH 114 ACCOUNTING OUTSIDE WSMALL SCREWDRIVER - TURNING INSIDE THRESHOLD, DOOR SWEEP HW-S SCHLAGE EXTRA HEAVY DUTY COMMERCIAL -SERIES W" ` 120 LA13 3'-0" 1'-0" 1-3/4" C SCWD TBD. HM. TAD. - I/A600 VAb00 1ID-4 • • • • • LEVER OR CLOSING DOOR RELEASES BUTTON. CLOSER ANSI PSI, STORE LOCK RHODES ADA LEVER HANDLES, %26 SA SIM 115 OMITTED SILENCED WALL OR FLOOR STOP W EFZE APPLICABLE. HW-6 IVES 8303 PULL PLATE WITH 1' DIA ROUND BAR 10' CHROME FINISH. KEY N EITHER LEVER LOCKS OR UNLOCKS 121 OMITTED 3'-0" 1'-0" 1-3/4" C SCWD TAD. HM TBD. - I/Ab00 VA600 HW-4 • • • • • CENTER TO :CENTM SATN CHROME FINISH LEVERS. PROVIDE CLOSER DOOR SWEEP, ADA THRESHOLD s aim 14W-3 SCWLAGE EXTRA HEAVY DUTY COMMERCIAL ND -SERIES IVIES 8200 PUSH PLATE: 3'XI2', SATIN CHROME FINISH WEATHERSTRIPS, METAL RAN GUARD, I6 W04 X 34 WIDE 116 OMITTED • • • • • <1 "MOM, A451 F86, STOREROOM LOCK FUNCTION, PROVIDE CONVENTIONAL CYLINDER (WITH THU'E3nW ON STANLESS STEEL KICKPLATE ON PUSH SIDE OF DOOR, 4 1/4'122 SHIPPING a' 3'-0" 1'-0" 1-3/4" C WAD TBD. HM TBD. - VA600 VA600 1419-4 RHODES ADA LEVER HANDLES, %26 SATN CHROME INTERIOR), CLOSER SILENCERS, DOOR STOP 4 16" HIGH X THICK DIAMOND PLATE KICKPLATE 61 HIGH X 401 WIDE INST I I SIM Ill OMITTED • • • • • EPDXY PAIN FINISH. OUTSIDE LEVER FIXED -ENTRANCE 5Y KEY 34' WIDE STAINLESS STEEL KICKPLATE ON PUSH SIDE OF ON CM BELOW DOOR y 123 It 3'-0" 1'-0" 1-3/4" C SCU)D TBD. HUM. TBD. - 1/A600 VA600 HW-4 ONLY - NUDE LEALWAYS UNLOCKED. CLOSER, DOOR SIM VER 118 OMITTED EPDXY PAIN SILENCERS. WALL OR FLOOR STOP WHERE APPLICABLE SCUD SOLID CORE WOOD WOOD DOOR 1235 OMITTED 3'-96" 1'-0" 1-3/4" C SCWD TBD. HM TBD. - VA600 VA600 HW-4 • • • • • 1 M HOLLOW METAL SM lie LAB • • • • • EPDXY PAIN FIRE RATED A98EhISLY (1-HOUR MW 124 5REAK ROOM PR 3'-0" 1'-0" 1-3/4" C SCUJD TBD. HM TBD. - I/A600 VA600 HW-4 �/ SIM 120 LAB • • • • � EPDXY PAIN � DOOR 4 FRAME T I PE5 a°'` 125 STORAGE 3'-0" 1'-0" I-3/4° C SCWD TBD. HM TBD. - 1/A600 VA600 Hw-3 3 SIM 121 DISPENSING EPDXY PAIN � 1255 OMITTED a 3'-0" 1'-0" 1-3/4" CUUD C STBD. HM TBD. 1/A601 3 SA601 I/A601 Hill-3 • • • • •aim EPDXY PAIN 122 SHIPPING 126 WASH ROOM 3'-0" 1'-0" 1-3/4" C arm Tim HM TBD. — 1/Ab00 VA600 HW-3 • • • • •,_4" V.I.F.V 3,_0�, '_4" V.IF. � ,a SIM 123 IT 124 BREAK ROOM • • • • • EPDXY PAIN 125 IT STORAGE • • • • _ - - �- 126 OMITTED • • • • • wad r r i- 121 WAW ROM • • • • • T+H 0 Ll ``"ss:uacm`�,`���\\.�o*e•, `a veat� !''�:,V ti1�.U o• �,� ``,c ,c�' a.+ DOOR TYPE ® DOOR TYPE © DOOR TYPE QQ DOOR TYPE QD FRAME TYPE QQ FRAME TYKE Q ALUM STOREFRONT NOT USED STAIN GRADE: SOLID PAINTED HOLLOW PAINTED HOLLOW PAINTED HOLLOW W/IMPACT GLASS CORE WOOD - FIRE METAL METAL - FIRE RATED METAL - FIRE RATED RATED AS REQUIRED AS REQUIRED AS REQUIRED GENERAL NOTES: I. ALL EXTERIOR STOREFRONT WINDOWS, CURTAIN WALLS, AND DOOR FRAMES ARE TO 5E ATTACHED TO THE STRUCTURE PER N.OA. DETAILS. 2. PROVIDE FIRE RATED DOOR ASSEMBLIES AS REQUIRED - REFERENCE FLOOR PLAN O IMPACT GLASS MA I E R I AL 5 5E L E C 110N 5CHE D UL. E COORDINATE ALL MATERIALS WITH THE OWNER PRIOR TO FURCNASE AND/OR INSTALLATION MARK DESCRIPTION SELECTION - MANUFACTURER FURNISH INSTALL REMARKS CARPET 12 FT WIDE BROADLOOM CARPET PATT: TBD COLOR: TBD G C G.C. PATTERNED, CUT PILE/ LOOP, Q&_W/SQYD MATERIAL/INSTALL ALLOWANCE CERAMIC TILE CERAMIC TILE (SIZE TBD) THROUGH BODY PORCELAIN TILE G.C./4" G.G. GROUT LINES, PATTERNED LAYOUT, R COLOTBD GROUT: TBD . $12.00/SQFT MATERIAL/INSTALL ALLOWANCE VCT VINYL COMPOSITE TILE TARKETT OR EQUAL, COLOR: TBD G.C.G.C.PROVIDE NECESSARY REDUCER STRIPS, t3.00/SQFT MATERIAL/INSTALL ALLOWANCE G-1 GROUT COLOR TO MATCH TILE G.C. G.G. MILDEW AND STAIN RESISTANT ADDITIVES, SEALED t5-1 TILE BASE THROUGH BODY PORCELAIN COLOR: TBD G.C.G.C.1/4" GROUT LINES, ALIGN WITH FLOOR GROUT LINES VB-i 4" H VINYL EASE ROPPE OR JOHNSONITE, TIGHTLOCK CO t G.C.G.C.COVE BASE, CONTINUOUS ROLL GOODS C5-1 4" H CARPET BASE MATERIAL TO MATCH CARPET G.C.G.C.PROVIDE FINISH/BOUND ENDS - COORDINATE WITH OWNER GYP. BD. PTD GYPSUM BOARD PAINTED - G.C.G.C.MOISTURE RESISTANT AT ALL WET LOCATIONS ACT-1 2'X2' ACOUSTICAL CEILING TILE/ WHITE GRID ARMSTRONG CEILINGS, CIRRUS, 9/1ro" GRID G.G. G.C.BEVELED TEGULAR EDGE, CLASS A CORNER GUARD TBD TBD G.C. G.C. PROVIDE AT ALL EXPOSED GYP BD EDGES - COORDINATE WITH OWNER'S CONSTRUCTION REP MINI- BLINDS TBD TBD OWNER G.C. COORDINATE WITH OWNER'S CONSTRUCTION REP PT-1 WALL PAINT, SATIN FINISH SHERWIN WILLIAMS, COLOR: TBD G.G. G.G. COORDINATE WITH OWNER'S CONSTRUCTION REP PT-2 ACCENT WALL PAINT, SATIN FINISH SHERWIN WILLIAMS, COLOR: TBD G.C. G.G. COORDINATE WITH OWNER'S CONSTRUCTION REP PT-3 DOOR FRAME PAINT, SEMI GLOSS FINISH SHERWIN WILLIAMS, COLOR TED G.G. G.C. I COORDINATE WITH OWNER'S CONSTRUCTION REP FT-4 EPDXY PAINT SHERWIN WILLIAMS, G.C. G.C. COORDINATE WITH OWNER'S CONSTRUCTION REP JAMB [DETAIL 30 = 1'-0" FRAMI= W/ (4) :HORS PER JAMB 4T. 5EAD SILICONE SLANT 15LE STUDS AT JAM5 IT. 5EAD SILICONE 4_ANT 6 W a 0 a a O U w W 0 W x Z O a D 0 w Z w w m J U) Wiedrick, Architecture, In?, .J WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 (, L_J§, > M Q J LL � U) U-)J � J W114- 0� 2(y) QI PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION 12/14/14 REV 01 - OWNER CHANCaES FIRST FLOOR FINISH 4 DOOR SCHEDULES MJW PROJECT #: 14022 A600 10/15/14 I 1 1 go PLUMBING LEGEND SANITARY SEWER (SAN) VENT (V) — — — -- COLD WATER (CW) HOT WATER RETURN (HWR) — — — HOT WATER (HW) — — SHUT—OFF VALVE SITE POINT OF CONNECTION SEEDS Engineering, Inc. 27730 Santa Anita Blvd. p: ( 813) 902-2515 Wesley Chapel, FL 33544 f: ( 813) 902-2516 jmakar@seedseng.com Florida Certificate of Authorization No. 28278 I 1 Wi r i k edc Architectue, I nc. r WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727,736.8627 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 Z O o M J Q CI F— LL � � U) L0 J LLJ I- n" � I: PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 r`I IC�IT• FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE DESCRIPTION 12/11/14 REV 01 - OWNER CHANGES FLUMBING FLOOR PLAN LUM5 G �LCC� FLAN N MJW PROJECT #: 14022 P 10 1 m i i i i i i i 2"V 1-1i .11 4" ,2"V I � I I I I 12"V I I I I 12-V 2"V I I I I I HS I I MS I I 3" I EW n FS 4" DISHWASHER FD 3" 3" 2" HS CONNECT TO EXISTING 4" SANITARY DISCONNECT SWITCH----,,, BY ELECTRICAL i SUBCONTRACTOR i VACUUM BREAKER: LTJ 36 WATTS OR EQUAL CHECKVALVE i GATE VALVE i COLD WATER - -i--XHN-f i i i i i I SERVICE DRAIN VALVE ASME T&P RELIEF VALVE: DWV COPPER FULL SIZE ROUTED TO DRAIN PAN WATER HEATER DRAIN: COPPER DWV ROUTED TO FLOOR DRAIN - - - - - WATER HEATER D ETA I L am 3"VTR JI THERMAL EXPANSION TANK: AMTROL "THERM-X-TROL" ST-12 HEAT TRAP HOT WATER DIELECTRIC UNIONS SAFETY PAN: 24 GAGE GALVANIZED SHEET METAL, 1-1/2" DEEP, SOLDERED LIQUIDTIGHT PLUMBING GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES. THIS SHALL INCLUDE THE 2010 FLORIDA BUILDING CODE AND THE 2010 FLORIDA PLUMBING CODE, WITH LOCAL AMENDMENTS. 2. REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING. INSTALLATION TO INCLUDE ALL PLUMBING FOR COMPLETE SYSTEMS DEPICTED ON THE PLANS. 3. COORDINATE WITH OTHER TRADES TO PREVENT CONFLICTS WITH HVAC DUCTS, ELECTRICAL LIGHTING AND STRUCTURAL ELEMENTS. 4. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL FIXTURES SHOWN ON THE PLUMBING FIXTURE SCHEDULE. VERIFY MOUNTING HEIGHT AND CONNECTION SIZES OF ALL PLUMBING FIXTURES PRIOR TO INSTALLATION. 5. ALL WORK, BOTH MATERIAL AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM ACCEPTANCE BY THE OWNER. WATER PIPING 1. THE WATER PIPING SHALL BE TYPE "K" COPPER BELOW GRADE, WITH VINYL SLEEVE FOR ANTI -CORROSION, AND TYPE "L" ABOVE GROUND WITH WROUGHT COPPER FITTINGS (ASTM B16.22-89) AND SOLDER JOINTS. 2. THE WATER SERVICE TO THE BUILDING IS EXISTING TO REMAIN. 3. THE MAIN BACKFLOW PREVENTER IS EXISTING TO REMAIN. 4. THE SITE WATER METER IS EXISTING TO REMAIN. 5. SUPPORT ALL PIPING WITH PIPE HANGERS EQUAL TO GRINNEL. 6. PROVIDE EACH FIXTURE WITH A SHUT-OFF SUPPLY STOPS. EXPOSED STOPS AND SUPPLY PIPING SHALL BE CHROME PLATED, WITH CHROME ESCUTCHEON PLATE AND SET SCREW. STOPS SHALL BE 8" AFF FOR WATER CLOSETS AND 16" AFF FOR LAVATORIES. 7. PROVIDE UNIONS FOR ALL CONNECTIONS TO SERVICEABLE EQUIPMENT. UNIONS SHALL BE DIELECTRIC WHERE DISSIMILAR METALS ARE CONNECTED. 8. INSULATE ALL HOT WATER PIPING WITH J" ARMAFLEX OR J" FIBERGLASS EQUAL TO MANVILLE MICRO-LOK AP-T. VAPOR SEAL ALL BUTT JOINTS. 9. PROVIDE WATER HAMMER ARRESTORS, EQUAL TO JR SMITH 5000 SERIES, IN ACCORDANCE WITH PDI STANDARD WH-201. FIELD FABRICATED SHOCK ABSORBERS ARE NOT ACCEPTABLE. 10. PROVIDE VACUUM BREAKERS AS REQUIRED BY CODE. 11. STERILIZE ALL WATER PIPING IN ACCORDANCE WITH HEALTH DEPARTMENT REGULATIONS. 12. TEST ALL WATER PIPING AT 100 PSIG FOR SIX HOURS OR AS REQUIRED BY THE JURISDICTION. 13. PROVIDE SHUT OFF VALVES FOR ALL EXTERIOR HOSE BIBS AND WALL HYDRANTS. 14. PROVIDE SERVICE VALVES AT EACH BRANCH SUPPLY LINE, AS DEPICTED ON THE PLAN. ALL VALVES, CHECK STOPS, ETC. SHALL BE RATED FOR 125 LB SERVICE. VALVES SHALL BE BALL OR GATE TYPE, GLOBE VALVES ARE NOT ACCEPTABLE. VALVES SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION FOR SERVICING AND OPERATION. SANITARY, WASTE AND VENT PIPING 1. SANITARY WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC DWV (ASTM-2665) WITH SOLVENT WELDED JOINTS. 2. SLOPE OF SANITARY AND WASTE PIPING SHALL BE UNIFORM, WITH A MINIMUM OF j" PER FOOT FOR 2" AND A MINIMUM OF I" PER FOOT FOR LARGER PIPING. 3. EXPOSED WASTE DRAINS IN RESTROOMS SHALL BE CHROME PLATED BRASS TUBING WITH MATCHING CHROME ESCUTCHEON PLATE. 4. PROVIDE INTERIOR AND EXTERIOR CLEANOUTS AS REQUIRED BY CODE. 5. FURNISH 4 LB LEAD OR 8 OZ COPPER VENT FLASHING FOR INSTALLATION BY THE GENERAL CONTRACTOR FOR ALL VENTS THROUGH ROOF. VERIFY TYPE OF ROOFING PRIOR TO INSTALLATION. 6. TEST SANITARY, WASTE AND VENT PIPING USING A 10 FOOT WATER COLUMN FOR 2 HOURS OR AS REQUIRED BY THE JURISDICTION. BATHROOM FLOOR DRAIN TRAP PRIMER DETAIL PLUMBING FIXTURE SCHEDULE ROUGH -IN MARK FIXTURE, MODEL #, DESCRIPTION WASTE VENT CW HW WC-HC WATER CLOSET, HANDICAPPED 3" 2" 1/2" KOHLER K-3519 WHITE ELONGATED, PRESSURE ASSISTED 1.0 GALLON FLUSH, TANK TYPE WATER CLOSET, OLSONITE #95 WHITE SEAT, CP STOP AND SUPPLY. LAV-HC LAVATORY, WALL HUNG, HANDICAPPED 1-1/2" 2" 1/2" 1/2" KOHLER K-2032 WITH K-11075-4 GOOSENECK FAUCET AND ADA COMPLIANT LEVER HANDLES, 1-1/4" CP P-TRAP, CP STOPS, SUPPLIES. WITH TRU-BRO INSULATION KIT. IMB ICE MAKER BOX 1/2" - RECESSED ICE MAKER BOX EQUIVALENT TO WATER TITE MODEL W9000 WITH WALL BOX FRAME AND COVER AND 1/2" SWEAT CONNECTION VALVE. EWC-SL ELECTRIC WATER COOLER, DUAL LEVEL, HANDICAPPED 1-1/2" 2" 1/2" ELKAY EZSTL8C COOLER, STANDARD COLOR, 1-1/2" 20 GAUGE CP P-TRAP, LESS CO, STOP AND SUPPLIES. MOUNT LOWER BOWL NOZZLE AT 30" A.F.F FOR ADA. EWH-40 ELECTRIC WATER HEATER 3/4" 3/4" A.O. SMITH DEN-40 R-16 FOAM INSULATED, GLASS -LINED 40 GALLON TANK, THREE (3) YEAR WARRANTY WATER HEATER. 45" HIGH x 20" DIAMETER, 3.0 kW ® 208 VOLT, 1 PHASE ELECTRIC HEATER. U.L. LISTED AND ASHRAE 90.1-1999 APPROVED. WITH GRUNDFOS RECIRC PUMP AND AQUA-STAT/TIMER. SCS SINGLE COMPARTMENT SINK 1-1/2" 2" 1/2" 1/2" ELKAY PSR1918-3 19"x18"x7" DEEP, 20 GAUGE TYPE 304 SELF -RIMMING SINK WITH LK2445 FAUCET AND LK99 DRAIN. 18 GAUGE P-TRAP, CP STOPS AND SUPPLIES. HS HAND SINK 1-1/2" 2" 1/2" 1/2" ELKAY EHS-18X 14"00"x5" DEEP, 18 GAUGE TYPE WALL HUNG SINK WITH GOOSENECK FAUCET AND STAINLESS STEEL DRAIN. 18 GAUGE P-TRAP, CP STOPS AND SUPPLIES. FD FLOOR DRAIN 31, 2" 1/2" ZURN Z415-6B-P 6" FLOOR DRAIN WITH TRAP -PRIMER CONNECTION AND TYPE "B" STRAINER. TP TRAP PRIMER 1/2" J.R. SMITH 2698 WATER SAVER TYPE, CP BRONZE PIPING AND ESCUTCHEON PLATES. ROUTE PRIMER PIPING IN WALL TO FLOOR DRAIN. WCO WALL CLEANOUT SEE ZURN Z1441 PLAN D.C.C.I. BODY WITH STAINLESS STEEL ACCESS COVER AND SECURING SCREW. FCO FLOOR CLEANOUT SEE - ZURN Z1400 PLAN D.C.C.I. BODY ADJUSTABLE TO FINISHED FLOOR. COTG CLEANOUT TO GRADE SEE ZURN Z1400-HD PLAN D.C.C.I. BODY ADJUSTABLE TO FINISHED GRADE WITH HEAVY DUTY TOP. SET IN 24"x24"x6" CONCRETE PAD. FS FLOOR SINK 3" 2'> 1/2" - ZURN Z1900-P-2 FLOOR SINK WITH HALF GRATE AND TRAP -PRIMER CONNECTION. EW EMERGENCY EYEWASH 1-1/2" 2" 1/2" BRADLEY S19-220 EYEWASH UNIT WITH CHROME PLATED, BRASS SPRAYHEAD ASSEMBLY WITH TWIN, SOFT FLOW, EYEWASH HEADS AND PROTECTIVE SPRAYHEAD COVERS. PROVIDE WITH WALL BRACKET AND PLASTIC BOWL. MS MOP SERVICE BASIN 3" 2" 3/4" 3/4" FIAT MSB2424 24 % 24" MOLDED STONE MOP SERVICE BASIN WITH 830-AA FAUCET, 832-AA HO E BRAC ET A D HANGER. NOTES: 1. APROVED MANUFACTURERS OF FIXTURES ARE AMERICAN STANDARD, ELJER AND KOHLER. 2. APPROVED MANUFACTURERS OF DRAINS AND CLEANOUTS ARE J.R. SMITH, ANCON, WADE AND ZURN. 3. ALL SUPPLIES SHALL BE PROVIDED WITH CP BRASS ANGLE STOPS, EASTMAN, BRASSCRAFT OR EQUAL, PROVIDED AT ALL FIXTURES. 4. ALL EXPOSED TRAPS AND WASTE ARMS SHALL BE CP BRASS, MCGUIRE OR EQUAL. PLUMBING LEGEND SANITARY SEWER (SAN) VENT (V) --- - - - - -- COLD WATER (CW) - HOT WATER RETURN (HWR) HOT WATER (HW) �- SHUT-OFF VALVE SITE POINT OF CONNECTION Wledrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 PRC),IFrT AnnRFS�1;- Jb444 �D I ti /AVt. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 PLUMBING NOTES AND DETAILS SEEDS Engineering, Inc. 27730 Santa Anita Blvd. p: ( 813) 902-2515 Wesley Chapel, FL 33544 f: ( 813) 902-2516 jmakar@seedseng.com Florida Certificate of Authorization No. 28278 NI J VV PROJECT #: 14022 201 A Em HVAC GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES. THIS INCLUDES THE 2010 FLORIDA BUILDING CODE AND THE 2010 FLORIDA MECHANICAL CODE, WITH LOCAL AMENDMENTS, THE APPLICABLE NFPA CODES AND THE FLORIDA ENERGY CODE. 2. ALL ELECTRICAL EQUIPMENT SHALL BE UL CLASSIFIED OR LISTED. 3. DEFINITIONS: "FURNISH" SHALL MEAN TO PURCHASE AND LOCATE AN ITEM ON THE JOBSITE. "INSTALL" SHALL MEAN TO PHYSICALLY INSTALL AN ITEM AND CONNECT IT TO ALL REQUIRED SERVICES TO MAKE THE ITEM FULLY FUNCTIONAL. "PROVIDE" SHALL MEAN TO BOTH FURNISH AND INSTALL THE ITEM. 4. TEST AND BALANCE SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR ON APPROVED FORMS USED BY AABC OR NEBB. THE MECHANICAL CONTRACTOR SHALL HAVE ALL SYSTEMS FULLY INSTALLED AND OPERATIONAL WITH CLEAN FILTERS INSTALLED PRIOR TO TEST AND BALANCE. AIR CONDITIONING EQUIPMENT 1. THE AIR CONDITIONING EQUIPMENT SHALL BE STRAIGHT COOL, WITH ELECTRIC HEAT. 2. ALL EQUIPMENT SHALL MEET THE MINIMUM EER REQUIREMENTS OF THE FLORIDA ENERGY CODE. 3. TRANE IS THE BASIS OF DESIGN WITH AMERICAN STANDARD, CARRIER AND YORK AS APPROVED ALTERNATES. IF AN ALTERNATE IS SUBMITTED, THE CONTRACTOR SHALL MAKE ALL NECESSARY CHANGES TO THE ELECTRICAL, STRUCTURAL AND DUCTWORK TO ACCOMMODATE THE SUBSTITUTION. 4. SUBMITTALS SHALL BE REVIEWED BY THE ELECTRICAL SUBCONTRACTOR FOR IMPACT TO THE ELECTRICAL SYSTEMS, PRIOR TO ORDERING THE EQUIPMENT. 5. ALL AIR CONDITIONING EQUIPMENT SHALL INCLUDE A MINIMUM 1 YEAR UNIT WARRANTY AND AN EXTENDED 4 YEAR COMPRESSOR WARRANTY. 6. PROVIDE 1" CONDENSATE PIPING AS SHOWN ON THE PLAN AND DETAIL. THE CONTRACTOR SHALL EXTEND THE CONDENSATE PIPING TO THE EXTERIOR TO SPILL TO SITE STORM RETENTION. 7. THE AIR CONDITIONING UNITS SHALL BE OPERATED DURING CONSTRUCTION WITH THROW AWAY FILTERS. FILTERS SHALL BE CHANGED DURING CONSTRUCTION IF THEY BECOME RESTRICTIVE OF AIR FLOW FOR NORMAL OPERATION. PROVIDE NEW FILTERS JUST PRIOR TO TEST AND BALANCE. 8. UNITS SHALL BE CLEANED AND ALL SCRATCHES PAINTED OVER WITH FACTORY PAINT TO MATCH UNIT. ALL CONDENSER COILS SHALL BE COMBED OUT AND ALL PANELS AND SCREWS SHALL BE INSTALLED AT THE COMPLETION OF THE PROJECT. DUCTWORK 1. SUPPLY AND RETURN DUCT SHALL BE 1-1/2" DUCT BOARD, INSTALLED IN ACCORDANCE WITH SMACNA. SEE DETAIL FOR INSTALLATION AND HANGING INSTRUCTIONS. 2. OUTSIDE AIR AND EXHAUST DUCT WORK SHALL BE GALVANIZED SHEET METAL WITH ALL JOINTS SEALED WITH MASTIC. ROUND DUCT WORK SHALL BE "THERMOFIN" OR SINGLE WALL SHEET METAL. DUCTS DO NOT NEED TO BE INSULATED UNLESS REQUIRED BY LOCAL JURISDICTION. ALL DUCT SHALL BE CONSTRUCTED AND INSTALLED PER SMACNA. 3. ALL DUCT SIZES DEPICTED ARE CLEAR INSIDE DIMENSIONS. 4. SUPPLY AIR DUCT SHALL BE SIZED AT 0.10"/100 FT. EQUAL FRICTION AND RETURN DUCT SHALL BE SIZED AT 0.06"/100 FT. EQUAL FRICTION. 5. HOLD THE BOTTOM OF THE SUPPLY AIR DUCT A MAXIMUM OF 24" ABOVE LAY -IN CEILINGS TO ALLOW FOR ACCESS TO BALANCING DEVICES. 6. PROVIDE A FLEXIBLE CONNECTION FROM EACH AIR HANDLER AND FAN TO THE DUCT SYSTEM. 7. FLEXIBLE RUNOUTS TO THE DIFFUSERS ARE LIMITED TO A MAXIMUM OF 25 FEET. 8. PROVIDE ACCESS PANELS IN DUCTS FOR ACCESS TO VOLUME DAMPERS, FIRE DAMPERS, FIRE/SMOKE DAMPERS, DUCT MOUNTED SMOKE DETECTORS AND WHERE REQUIRED TO MAINTAIN EQUIPMENT. 9. ALL FLEXIBLE BRANCH CONNECTIONS SHALL HAVE A MANUAL VOLUME DAMPER INSTALLED AT THE MAIN TRUNK FOR BALANCING PURPOSES. CONTROLS 1. ALL TEMPERATURE CONTROLS SHALL BE 24 VOLT, AS PROVIDED BY THE MECHANICAL CONTRACTOR. 2. THERMOSTATS SHALL BE PROGRAMMABLE EQUAL TO HONEYWELL T8000 SERIES, OR BY UNIT MANUFACTURER, WITH STAGES OF COOLING AND HEATING TO MATCH THE UNITS SELECTED. MOUNT THERMOSTATS AT 5'0" AFF OR AS DIRECTED BY ARCHITECT/OWNER. 3. LOW VOLTAGE CONTROL WIRING SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR.THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT FOR ALL CONTROL WIRING AS COORDINATED WITH THE MECHANICAL CONTRACTOR. 4. LINE VOLTAGE (110 VOLT OR HIGHER) POWER AND CONDUIT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL DISCONNECT SWITCHES. DO NOT MOUNT DISCONNECT SWITCHES OVER NAMEPLATES OR SERVICE PANELS. 6. TEST AND BALANCE SHALL VERIFY THE OPERATION OF ALL CONTROLS AT THE COMPLETION OF THE PROJECT. 7. WHERE SMOKE DETECTORS ARE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR (NO FIRE ALARM SYSTEM), EACH SMOKE DETECTOR SHALL BE EQUIPPED WITH A REMOTE TEST STATION EQUIPPED WITH A VISUAL AND AUDIBLE ALARM TO BE LOCATED ADJACENT TO THE UNIT THERMOSTAT IN ACCORDANCE WITH NFPA 90. AIR DISTRIBUTION SCHEDULE DESIGNATION DESCRIPTION LEGEND SPECIFICATIONS EXAMPLE CD1-10-270 CEILING DIFFUSER CD1 PRICE ASCD SERIES, ALUMINUM, NECK SIZE NOTED 10" MODULAR CORE, LAY -IN MOUNTED, CFM NOTED 270 OFF-WHITE COLOR. RG1-24x24-300 RETURN GRILLE RG1 PRICE 610, ALUMINUM FACE SIZE NOTED 24x24" LOUVERED CORE, LAY -IN MOUNTED, CFM NOTED 300 OFF WHITE COLOR. RG2-16x16-160 RETURN GRILLE RG2 PRICE 610, ALUMINUM FACE SIZE NOTED 1606" LOUVERED CORE, SURFACE MOUNTED, CFM NOTED 160 OFF WHITE COLOR. NOTES: 1. SIZES AND CFM SHOWN ON THE LEGEND ABOVE ARE FOR EXAMPLE ONLY. SEE PLAN FOR ACTUAL SIZES AND CFM VALUES USED ON THIS PROJECT. 2. LOCATE ALL AIR DISTRIBUTION PER THE ARCHITECTURAL REFLECTED CEILING PLAN 3. APPROVED MANUFACTURERS: PRICE, METALAIRE, KRUEGER, TITUS BUILDING AIR BALANCE OUTSIDE AIR INTO BUILDING EXHAUST AIR OUT OF BUILDING SOURCE CFM SOURCE CFM AHU-1 AHU-2 AHU-3 AHU-4 120 120 225 225 TEF-1 TEF-2 EXFILTRATION 50 50 490 TOTAL OUTSIDE AIR IN = 690 1 TOTAL EXHAUST AIR OUT = 590 BUILDING PRESSURIZATION = +100 OUTSIDE AIR CALCULATION SCHEDULE SPACE PEOPLE/SQUARE FEET REQUIRED CA PROVIDED CA OFFICE 32 / 3506 SF 371 400 PHARMACY 1 / 242 SF 49 55 SALES 6 / 733 SF 183 200 STORAGE 0 / 477 SF 29 35 NOTE: 1. OUTSIDE AIR VOLUMES ARE BASED UPON ASHRAE STANDARD 62.1 SEEDS Engineering, Inc. 27730 Santa Anita Blvd. p: (813) 902-2515 Wesley Chapel, FL 33544 f: (813) 902-2516 jmakar@seedseng.com Wiedrick Architecture, 1 nc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 STATE OF FLORIDA REGISTERED ARCHITECT: MATTHEW WIEDRICK A R94577 M444 b I H lHVE=. ZEPHYRHILLS, FL 33542 FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 MECHANICAL FLOOR PLAN (-,-)_MECHANICAL FLCCF� FLAB 3/1(011:1'-011 N Florida Certificate of Authorization No. 28278' IVI J VV PROJECT #: 14022 REFRIGERANT PIPING NEOPRENE HANGER ISOLATORS DISCONNECT OR CIRCUIT BREAKER LOCATION: BY ELECTRICAL CONTRACTOR. SINGLE POINT SERVICE. I I �� LIJ I II � II I SUPPLY I I I II I AIR I I � DUCT RETURN I I II I TAIR DUCT I I �� �_JL FLOAT SWITCH: LOCATED AT LOW SPOT IN DRAIN PAN, TO SHUT DOWN UNIT IF WATER GETS INTO THE DRAIN PAN. CONDENSATE DRAIN AND P-TRAP: 1" COPPER, 1/2" ARMAFLEX INSULATION AUXILLARY DRAIN PAN: 22 GAUGE SHEET METAL SOLDERED WATER -TIGHT. 2" DEEP & 3" LARGER THAN UNIT. SUPPORT FROM DUCTWORK ONLY. AIR HANDLER, 1 MARK --- AHU-1,2 AHU-3,4 MANUFACTURER --- TRANE TRANE MODEL --- GAM5BOA36 GAM5BOA60 CAPACITY TONS 3.0 5.0 TOTAL COOLING MBH 36 60 SENSIBLE COOLING MBH 27 45 SUPPLY AIR CFM 1200 1 2000 1 OUTSIDE AIR CFM 120 225 EXTERNAL STATIC PRESSURE IN H2O 0.6 0.6 FAN MOTOR HP/FLA 1 /2/4. 1 1 /7.6 ELECTRIC HEAT KW/VOLTS 7.68 7.68 FILTER TYPE --- - - ELECTRICAL DATA V/PH/HZ 240/1 240/1 MCA AMPS 45 50 MOCP AMPS 45 50 LOCATION --- SEE PLAN SEE PLAN WEIGHT LBS 142 170 HANGER SUPPORTS: 1/4" THREADED ROD & NEOPRENE ISOLATORS, DO NOT SUPPORT FROM CEILING DISCONNECT SWITCH: FURNISHED BY THE MECHANICAL i SUBCONTRACTOR i VARIABLE SPEED i CONTROLLER o CEILING i O SEAL ALL SHEET METAL DUCT WITH MASTIC ONLY (NO TAPE) - BACKDRAFT DAMPER: CLEAR OF SCREWS EXHAUST GRILLE: BY FAN MANUFACTURER CEILING FAN DETAIL MARK - TEF-1,2 MANUFACTURER - GREENHECK MODEL - SP-1370 SERVICE - SEE PLAN AIR QUANTITY CFM 50 EXTERNAL STATIC PRESSURE IN H2O 0.3 FAN TYPE - CENTRIFUGAL MAXIMUM FAN SPEED RPM 643 DRIVE - DIRECT MOTOR HP(W) 45 W ELECTRICAL V/PH/HZ 115/1 CONTROLS - WITH LIGHTS SONES - 2.0 WEIGHT LBS. 9 NOTES - - UNIT SHALL BE EQUIPPED WITH: ANTI -SHORT CYCLE TIMER CRANKCASE HEATER 10 YEAR COMPRESSOR/COIL WARRANTY HIGH PRESSURE SWITCH LOW PRESSURE SWITCH LIQUID LINE FILTER/DRIER I■ SECURE TO PAD WITH \ 16 GAGE STRAP AND SCREWS. (2) PER SIDE EQUIPMENT PAD B, GENERAL CONTRACTOR DISCONNECT OR CIRCUIT BREAKER LOCATION: BY 4 ELECTRICAL CONTRACTOR. it -I DO NOT MOUNT ON UNIT. NTROL WIRING: APPROVED IRE -TIES" FRIGERANT PIPING: RVICE VALVES: EXTERNAL UNIT ATION ISOLATION PADS: 3/8" THICK, RIBBED, NEOPRENE CONDENSER UNIT MARK --- CU-1,2 CU-3,4 MANUFACTURER --- TRANE TRANE MODEL --- 4TTB3036E1 4TTB306OD1 CAPACITY TONS 3.0 5.0 CIRCUITS NO. 1 1 EFFICIENCY SEER/EER 13 13 COMPRESSOR NO/RLA 1/15.3 1/26.8 CONDENSING FAN NO/FLA 1 /0.74 1 /0.93 ELECTRICAL DATA V/PH/HZ 240/1 240/1 MCA AMPS 20 35 MOCP AMPS 35 60 LOCATION --- SEE PLAN SEE PLAN WEIGHT LBS 159 226 NOTES --- - - HANGER SUPPORTS: ROUND 'SNAPLOCK" SHEET 8' O.C. = 0-35" DUCTS METAL FOR RUN -OUTS 6' O.C. = 36-59" DUCTS GREATER THAN 25', WITH ( 1", 22 GAUGE - TYPICAL) 2" WRAP INSULATION. AN S N� EE I [2R SADDLE:22 GAUGE 24" MAXIMUM APPROVED EQUAL IS "SPIRO-PIPE" SPIN -IN FITTING: WITH SCOOP AND DAMPER, EXCEPT IN GYP. BOARD CEILINGS, DAMPER IN NECK I ---------- I TAPE AND MASTIC I I I OUTER JACKET ( TYPICAL ) I MINIMUM RADIUS EQUAL TO THE FLEX DUCT DIAMETER. / FLEXIBLE DUCT: MAXIMUM 25 FEET, DO NOT SAG OR KINK FIBERGLASS TAPE SUPPORTS TO PREVENT SAGS AND KINKS IN FLEX BAND CLAMP AND THREE SHEET METAL SCREWS THROUGH HELIX OF FLEXIBLE DUCT LINER (TYPICAL) VERTICAL DUCT RUN 11 REINFORCEMENT: // WRAP INSULATION ABOVE CEILING DIFFUSER: SET 0-24" = NOT REQUIRED THE CEILING DIFFUSERS THROW AS SHOWN ON PLANS 25"+ = REQUIRED AT 24" O.C. FIBERGLASS DUCT DETAIL 1. FIBERGLASS DUCTS SHALL BE FABRICATED & INSTALLED PER THE LATEST EDITION OF SMACNA AND THE 2010 FLORIDA ENERGY CODE WITH LOCAL AMENDMENTS. MATERIAL SHALL BE 1-1/2" 800 El BOARD, WITH A MINIMUM 6.0 "R" VALUE AND BE NFPA 90A APPROVED. 2. FABRICATION SHALL BE MACHINE CUT V-GROOVE OR SHIPLAP: BUTT JOINTS ARE NOT ACCEPTABLE. DUCT CLOSURE METHOD SHALL BE WITH GLASS FABRIC AND MASTIC USING "EPOLUX CADOPRENE 725", PRESSURE SENSITIVE TAPE, OR HEAT SEALABLE TAPE. ALL CLOSURE METHODS SHALL BE PER MANUFACTURERS INSTALLATION INSTRUCTIONS AND SHALL MEET THE REQUIREMENTS OF UL 181 FOR A CLASS 1 AIR DUCT SYSTEM. 3. SHEET METAL SLEEVES SHALL BE PROVIDED FOR; VOLUME DAMPERS, BRANCH TAKE -OFFS, REGISTER & GRILLE CONNECTIONS, RECTANGULAR DUCT CONNECTIONS, FIRE DAMPERS & DUCT HEATERS. 4. REINFORCEMENT CHANNELS, OR TEES, SHALL BE PROVIDED AS NOTED ABOVE & AT ALL ELBOWS OR AT ALL BRANCH CONNECTIONS, PER FIGURE 4.1. 5. HANGER SUPPORTS SHALL BE AS NOTED ABOVE (PER FIGURE 5-1D) FOR DUCTS UP TO 24", AND WITH TRAPEZE HANGERS (PER FIGURE 5-18 OR 5-1C) FOR DUCTS 25" AND ABOVE. 6. ELBOWS SHALL BE SQUARE NECK (SAME IN OUT DIMENSION) WITH 2" DOUBLE THICKNESS TURNING VANES. 7. OFFSETS SHALL NOT EXCEED 30- ANGLE, AND SHALL NOT REDUCE THE FREE AREA OF THE DUCT. 8. TRANSITIONS SHALL NOT EXCEED 1:3 RATIO (4" TRANSITION PER FOOT SINGLE SIDED TRANSITION, AND 8" PER FOOT DOUBLE SIDED TRANSITION). 9. RECTANGULAR BRANCH CONNECTIONS SHALL BE 45' ENTRY TYPE, WITH METAL SLEEVE & CLINCH LOCK CONNECTION. ENTRY LENGTH SHALL BE 25% OF BRANCH DUCT WIDTH. 10. ROUND DUCT CONNECTIONS SHALL BE WITH "METAL MANUFACTURING COMPANY" TL-FD-6 SPIN -IN FITTINGS, WITH SCOOP, DAMPER AND HANDLE. 11. FLEXIBLE ROUND DUCT SHALL INCLUDE: AN INNER POLYTHYLENE LINER, A SPRING HELIX, A 1-1/2" BLANKET INSULATION WITH MINIMUM 6.0 "R" VALUE AND AN ALUMINUM FOIL OUTER VAPOR BARRIER, AND BE UL-181 APPROVED. SUPPORT CHANNEL: "HYDRO ZORB" OR "SUPER -STRUT" REFRIGERATION PIPING BIRDSCREEN REMOVABLE TOP: SPUN ALUMINUM FACTORY CURB: r� SEE DETAIL ---_ COORDINATE WITH OTHER TRADES TO AVOID PIPING & CONDUIT INTERFERENCES WITH ROOF INTAKE DUCTWORK PIPE CLAMPS: "HYDRO RT", OR "SUPER -STRUT", ROOF INTAKE DETAIL WITH SIZE TO MATCH ELECTRICAL CONDUIT. REFRIGERANT PIPING DETAIL 1. ALL REFRIGERANT PIPING SHALL BE HARD COPPER, ACR TYPE "L", WITH LONG RADIUS ELBOWS AND WROUGHT FITTINGS. 2. TRAPS SHALL BE SINGLE PIECE, WROUGHT COPPER. 3. INSULATE SUCTION LINES FULL LENGTH WITH "ARMAFLEX" INSULATION. THICKNESS SHALL BE 1/2" UP THROUGH 7/8" SUCTION LINE SIZE, WITH 3/4" THICKNESS FOR 1-1/8" SUCTION LINES & ABOVE. ALL INSULATION SHALL BE ASTM E84 APPROVED (FLAME SPREAD OF 25, SMOKE DENSITY OF 50). 4. INSULATION SHALL NOT BE SPLIT DURING INSTALLATION. 5. ROUTING OF ALL REFRIGERANT PIPING SHALL BE "SQUARE WITH" BUILDING LINES. HORIZONTAL PIPING SHALL BE SLOPED AT THE RATE OF (1) INCH FOR EACH (10) FEET, TOWARD THE COMPRESSOR. 6. SUPPORT OF THE REFRIGERANT PIPING AT THE COMPRESSORS, CONDENSERS, AND AIR HANDLING UNITS SHALL BE AS SHOWN ABOVE. 7. SUPPORT OF THE REFRIGERANT PIPING, IN CEILING PLENUMS, SHALL BE WITH STRAP HANGERS, SHEET METAL "SADDLES", WITH 3/4" INSULATION TO ELIMINATE ANY METAL -TO -METAL CONTACT. 8. BRAZE ALL REFRIGERANT PIPING WITH A FLOW OF DRY NITROGEN DURING THE BRAZING OPERATIONS. 9. SOLDER SHALL BE 15% SILVER "SIL-FOS" OR EQUAL. 10. CHANGE FILTER -DRIER CORES AFTER 30 DAYS OF OPERATION. SAVE CORES FOR INSPECTION BY TEST & BALNCE, OR BY OWNERS REPRESENTATIVE INSPECTION. ROOF INTAKE DUCTWORK: NO INSULATION, MASTIC SEAL MECHANICAL SUBCONTRACTOR SHALL GENERAL CONTRACTOR SHALL PROVIDE ITEMS NOTED BELOW PROVIDE ITEMS NOTED BELOW TIE -DOWN BOLTS: TWO PER SIDE; 3/8" LAG BOLTS ROOF EXHAUST CAP PRESSURE -TREATED NAILER STRIP HEIGHT OF CURB ABOVE - ROOF DECK: 18" FOR STANDARD FANS CURB: "VENT PRODUCTS" 8121, 18 GAGES GALVANIZED STEEL, WELDED, RIGID INSULATION, WITH 45' RAISED CANT TO ADAPT TO THICKNESS OF ROOF INSULATION CURB SET ON TOP OF METAL DECKI M1.111[eL`11:09 ING ROOF INSULATION �- METAL DECKING -BOLT SETS: 3/8", (2) PER SIDE, THRU BASE OF CURB AND FRAME STRUCTURAL SUPPORT FRAME, FOR UNIT & DECKING, AT FULL PERIMETER OF FACTORY CURB CURB DETAIL: FAN OR GRAVITY VENTILATOR 1. MECHANICAL SUBCONTRACTOR SHALL VERIFY THICKNESS OF ROOF INSULATION PRIOR TO ORDERING CURBS NOTED ABOVE. 2. CURBS NOTED ABOVE DO NOT NEED TO BE SET LEVEL, AND CAN BE SET WITH THE PITCH OF THE ROOF. SEEDS Engineering, Inc. 27730 Santa Anita Blvd. p: (813) 902-2515 Wesley Chapel, FL 33544 f: (813) 902-2516 jmakar@seedseng.com Florida Certificate of Authorization No. 28278 Wiedrick Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 J I A It Ur rLUKIUA REGISTERED ARCHITECT: MATTHEW WIEDRICK AR94577 M A kq'A,'/�i , V�C,ENSF • . �• No.54827 wo_ • z STATE OF �A '' LORIOP:•' e, -. w W N ° Q T 0 U CLIENT.- FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY. FL 33525 > IECHANIGAL NOTES AND DETAILS PROJECT #: 14022 a R M , r I m Elmo. r DIVISION 16000 ELECTRICAL SPECIFICATIONS SECTION 16010 GENERAL PROVISIONS PART 1-GENERAL 1.01 WORK INCLUDED A. Furnish all labor, materials, and equipment as required by the plans and specifications to provide a complete and operable electrical system. This specification describes the types of materials, methods, and management to be utilized. This includes the work listed in this division as well as equipment furnished under other divisions not specifically mentioned herein. B. Guarantee all materials and labor for a period of (1) year from date of substantial completion. Pass on any additional manufacturer warranties to the owner. C. Contractor shall coordinate with electric and telephone utilities prior to bid and furnish both with their required sets of plans within 10 days of being awarded project. Obtain pdfs of plans from GC to plot and send to the utility companies. 1.02 CODES AND STANDARDS A. All equipment, materials, and methods of design and installation are to comply with the National Electrical Code (NEC), the Occupational Safety and Health Act (OSHA), and the requirements of applicable local codes. Codes and standards of the following organizations may be referred to in this section and shall be considered as the minimum acceptable. A reference herein to any portion of the standard or code is not to be considered as negating any other portion of the standard or code. 1. National Electrical Code (NEC), 2008 ed. 2. National Electric Manufacturers Association (NEMA) 3. Underwriters Laboratories, Inc. (UL) 4. Florida Building Code (FBC), 2010 ed. 5. Florida Fire Prevention Code (FFPC), 2010 ed. 1.03 EQUIPMENT, MATERIAL AND WORKMANSHIP A. All equipment and material shall be new unless allowed below, free from defects, of current manufacture, and listed by Underwriters Laboratories, Inc., (UL) where UL requirements apply. All materials are to be products of reputable and experienced manufacturers. B. Provide protection for materials and equipment against loss or damage throughout the contract. Provide protection from the effect of weather prior to installation, store items to be installed in indoor weather protected location. C. Following installation, protect materials and equipment from corrosion, physical damage and effects of moisture on insulation. D. Do not cut or notch any structural member or building surface without specific approval of the Structural Engineer. E. All work will be performed by accomplished, qualified and experienced personnel working under continuous competent supervision. R Contractor shall restore fire ratings of all rated assemblies penetrated with the appropriate assembly: W-L-1049, W-L-3214, W-L-4008, C-AJ-1353, C-AJ-1354, C-AJ-1080, or equivalent suitable with penetrant and wall/floor assembly. 1.04 PERMITS A. Obtain and pay for all permits and inspections pertinent to the electrical installation. 1.05 SITE INSPECTION A. Prior to submitting a bid, visit the project site and ascertain conditions affecting the proposed work and all existing electrical facilities. B. Furnish all labor associated with accompanying Engineer during observations of construction. 1.06 TEMPORARY INSTALLATION A. Provide all temporary lighting and 120V/20A power reachable with a 100ft extension cord for use by trades. B. Temporary installation shall conform to the requirements of the NEC, OSHA, and the State and local governing bodies. C. Pay all cost for temporary power services and power usage charges until project final acceptance by owner. 1.07 SHOP DRAWINGS A. Submit 6 copies of all project submittal data and shop drawings. B. Submit complete shop drawings for review prior to purchase of the following: 1. Light fixtures. 2. Wiring devices. 3. Panelboards, switchboards, transformers, safety switches, and fuses. 4. Fire alarm system. C. Contractor shall review shop drawings and submittals of every trade where an electrical connection is required and report any variances from electrical characteristics noted on the electrical drawings to the Engineer before proceeding with rough -in work. 1.08 RECORD DRAWINGS A. Maintain a neatly marked set of record drawings showing installation location, and/or routing of conduits, depth of buried cables, pull boxes, junction boxes, outlets, and a single -line diagram of the building electrical distribution system and floor plans indicating location and area served for all distribution. After final inspection, within 30 days after the date of system acceptance, transfer all record information to the Owner as required in the contract. B. If the contractor elects not to utilize circuitry as designated on plans and in schedules, contractor shall provide as -built markups of plans and schedules to engineer. C. An operating manual and maintenance manual shall be provided to the building owner. The manuals shall include, at a minimum, the following: 1. Submittal data stating equipment rating and selected options for each piece of equipment requiring maintenance. 2. Operation manuals and maintenance manuals for each piece of equipment requiring maintenance. Required routine maintenance actions shall be clearly identified. 3. Names and addresses of at least one qualified service agency. PART 2 - EXECUTION 2.01 INSTALLATION A. The electrical plans show general arrangements and locations for equipment conduit, outlets, etc. Unless detailed or dimensioned, exact locations of conduit, routing of cables and placement of equipment will be governed by structural conditions, physical interference, owner equipment, and locations of electrical termination on equipment. Examine architectural, structural, and mechanical plans and shop drawings for the various equipment in order to determine exact routing and placement of all raceways, cables, and equipment, to assure a workable installation in accordance with NEC. Such coordination shall be anticipated during bid. B. Where plans and specifications or schedules are in conflict, contractor shall assume the most stringent requirements apply and submit an RFI prior to submitting bid. C. Any product substitutions from specified make & model numbers shall be qualified in bid in writing with explanation of reason for substitution and cost savings associated with substitution. D. Contractor shall obtain Fire Protection drawings where ESFR fire protection is installed and maintain 12" clearance (24" if FM Global has jurisdiction) from all ESFR sprinkler heads with light fixtures, raceways, and any other electrical component. ***END OF SECTION*** SECTION 16070 ELECTRICAL CONNECTIONS FOR EQUIPMENT PART1-GENERAL 1.01 WORK INCLUDED A. Provide all labor, materials and equipment as required furnishing connections to all electrical equipment, lights, etc. PART 2 - PRODUCTS 2.01 GENERAL A. See Section 16111, Conduit Raceways; Section 16140 Wiring Devices; and Section 16120 Wire and Cables for additional requirements. Provide final connections for equipment consistent with the following: 1. Permanently installed fixed equipment - flexible seal-tite conduit from branch circuit terminal equipment, or raceway; to equipment, control cabinet, terminal junction box, or wiring terminals. Totally enclose all wiring in raceway. 2. Movable and/or portable equipment - wiring device, cord cap, and multi -conductor cord suitable for the equipment and in accordance with NEC requirements (Article 400). 3. Other methods as required by the National Electrical Code and/or as required by special equipment or field conditions. PART 3 - EXECUTION 3.01 INSTALLATION OF ELECTRICAL CONNECTIONS A. Make electrical connections in accordance with connector manufacturer's written instructions and with recognized industry practices, and complying with requirements of NEC and NECA's "Standard of Installation" to ensure that products fulfill requirements. B. Connect electrical power supply conductors to equipment conductors in accordance with equipment manufacturer's written instructions and wiring diagrams. C. Verify all electrical loads (voltage, phase, full load amperes, number and point of connections, minimum circuit ampacity, etc.) for equipment furnished under other Sections of this specification, by reviewing respective shop drawings furnished under each section. Report any variances from electrical characteristics noted on the electrical drawings to the Engineer before proceeding with rough -in work. D. Obtain and review the equipment shop drawings to determine particular final connection requirements before rough in begins for each equipment item. E. Contractor shall pay particular attention to lug arrangements in project submittal data, as well as in the field when equipment arrives, with respect to specified conductors for every piece of equipment and report any variances from electrical characteristics noted on the electrical drawings to the Engineer before proceeding with rough -in work. ***END OF SECTION*** SECTION 16111 CONDUIT RACEWAYS PART1-GENERAL 1.01 WORK INCLUDED A. Furnish all labor, materials and equipment as required to install all flexible or rigid conduit, couplings, supports and nonmetallic ducts, as shown on the Plans. PART 2-PRODUCTS 2.01 MATERIALS A. GENERAL: Provide conduit, and fittings of types, grades, sizes, and weights (wall thicknesses) as indicated; with minimum trade size of 1/2" above grade and 3/4" below grade. B. Electrical Metallic Tubing (EMT) with die cast or steel set -screw fitting for dry and damp locations, compression for wet locations. C. RIGID METAL CONDUIT (RMC) with threaded fittings and UL 6 listing. D. RIGID NON-METALLIC CONDUIT (RNC): Schedule 40, with matching glue -on socket fittings. E. FLEXIBLE METALLIC CONDUIT (FMC): Galvanized interlocked steel strip with positive locking cadmium plated steel or malleable iron fittings. F. LIQUID -TIGHT FLEXIBLE METAL CONDUIT (LT): Provide liquid -tight, flexible metal conduit; constructed of single strip, flexible continuous, interlocked, and double -wrapped steel; galvanized inside and outside; coated with liquid -tight jacket of flexible polyvinyl chloride (PVC) with positive locking cadmium plated steel or malleable iron fittings and compression type steel ferrule and neoprene gasket sealing rings. G. EXPANSION FITTINGS: OZ Type AX, or equivalent to suit application. 2.02 SCHEDULE OF LOCATIONS A. RMC or Schedule 80 PVC in all areas subject to physical damage to an elevation of 48" AFF/AFG. B. EMT for all above grade areas in the building unless noted otherwise. C. RNC for all areas below grade. D. LT for all exposed locations within coolers and freezers. E. Make connections to motors and equipment with FMC and LT as environmental conditions dictate. PART 3 - EXECUTION 3.01 INSTALLATION A. Install conduit concealed in all areas where possible. B. Coordinate installation of conduit in masonry work. C. Plug ends of conduits to prevent entry of dirt or moisture. Provide non -shrinking electrical putty to seal conduits which emerge from grade after conductors are installed. D. Route all exposed conduits parallel or perpendicular to building lines. E. Do not exceed number of bends in conduit beyond that allowed by the NEC. F. PVC conduit runs less than 50 ft shall incorporate Schedule 80 elbows, over 50 ft use RMC coated with bitumastic. Prior to backfill, take digital photographs. G. Keep conduits at least 12" away from gas lines and hot water pipes, and in no case permit conductors to reach higher than rated temperatures. H. Fasten raceways securely in place. Firmly fasten conduit within three feet of each outlet, junction box, cabinet, or fitting. Support metallic conduit in accordance with the NEC. Use "bolt -on" raceway fasteners designed for the purpose in exposed and wet areas, "snap -on' black metal "Caddy" clips in metal stud walls and above ceilings. All fasteners, straps, clips, etc. shall be UL listed for their use. Where conduit is surface mounted in kitchen, secure with stand-off style straps which allow all sides of the conduit to be cleaned. I. Weatherproof any penetration through exterior of building including slab on grade. J. Provide pull boxes as dictated by wire pulling requirements. Unless shown otherwise, face into secondary or unfinished rooms. K. All raceways shall be kept at least 1-1/2" away from metal roof decking. L. All empty raceways used for structured cabling shall be terminated with connectors and bushings. M. Make watertight roof penetrations at equipment served. Conduits shall not be run horizontally exposed on top of roofs. N. Provide suitable protection of conduits during construction to prevent debris from entering while conduits are not terminated. O. Do not install raceways within 12" horizontally of ESFR sprinkler heads (24" if FM Global has jurisdiction). ***END OF SECTION*** SECTION 16120 BUILDING WIRE AND CABLE PART 1- GENERAL 1.01 WORK INCLUDED A. Furnish all labor, materials, and equipment as required to install all wires and cables as shown on the Plans, and as required to connect all electrical services and equipment. PART 2 - PRODUCTS 2.01 MATERIALS A. All wiring shall be copper unless specifically noted otherwise on plans. Where type XHHW-2 aluminum conductors are permitted per the plans, conductor terminations shall be made with compression pigtail adapters (ILSCO Type ACM or ACO) with anti -oxidant applied to exposed conductor. Owner is advised to refer to NFPA 70B for periodic inspection recommendations. B. Minimum size conductors and insulation types: 1. Branch circuits and feeders, # 12 AWG THHN/THWN. 2. Service entrance, XHHW or THWN. 3. Control circuits, # 14 AWG THHN/THWN. C. MC Cable may be used in lieu of conduit and wire where installed in accordance with all of the following conditions. 1. Concealed and only where approved by owner. 2. Per requirements of the NEC and local codes. 3. Branch circuits 30 amps and below. 4. Where installed after the first junction box from a panel, i.e. do not connect MC cable to panelboards. PART 3 - EXECUTION 3.01 INSTALLATION A. Color coding shall be as follows: Voltage Phase A Phase B Phase C Neutral 120/240 Black Orange Blue White B. Provide a green grounding conductor in all raceways except service entrance. Provide a green with yellow stripe conductor in raceways with isolated ground conductors specified on plans. C. Provide conductors with identification tags as manufactured by Brady or approved equal. D. Install wires and cables continuous without splices from source of supply to distribution equipment and from source of supply to motors, lighting, or power outlets. Do not use pull boxes for making splices. Do not install splices in conduits or trench. E. Support vertically installed conductors at intervals not to exceed those allowed by the NEC. Do not splice vertically installed conductors. F. Remove any existing wiring (line voltage and low voltage) which is abandoned in place or will become obsolete due to construction. G. Any feeder lengths described in Voltage Drop or Fault Current Study tables are not to be relied upon for bidding or construction. Contractor is advised to review specification 16010, 2.01, A for coordination with other trades which may affect feeder installation routing and lengths. H. Prior to energizing, check service lateral and feeders for electrical continuity and clear of short-circuits. Check with "Megger" tester for phase -to -phase, phase -to -neutral, and phase -to -ground insulation resistance levels to insure system insulation levels are in accordance with manufacturer's recommendations. Use 500 volt tester for 208 volt and 240 volt applications;1000 volt tester for 480 volt applications. If resistance levels are low, take corrective measures as necessary including but not limited to replacement of all materials as required. ***END OF SECTION*** SECTION 16130 PULL AND JUNCTION BOXES PART1-GENERAL 1.01 DESCRIPTION A. Construct junction or pull boxes less than 100 cubic inches as "standard outlet boxes". B. Construct junction or pull boxes greater than 100 cubic inches as "cabinets". C. Provide all covers of same gauge metal and include screws. PART 2 - PRODUCTS 2.01 STANDARD OUTLET BOXES A. Make of material resistant to corrosion or suitably protected, both internally and externally by galvanizing. B. Boxes installed in damp or wet locations shall be U.L. approved for the purpose. C. Metal boxes to meet NEC construction specifications. D. Boxes exposed or surface mounted shall be die-cast or permanent- mold cast aluminum body with threaded external hub and cast cover. E. Provide in -ground junction box, Quazite #PG1118BA12 /PG1118HH00 or equivalent for in ground applications. Top flush with finished grade. 2.02 CABINETS A. 14 gauge sheet steel with corrosion resistant finish. B. Ample space for wires, connections and equipment. C. Cabinet fronts: Sheet steel panels with hinged door and locking provisions. D. Flush cabinets: Cover shall be approximately 3/4" larger than cabinet on all sides, set with front firmly against the finished wall surface. E. Telephone cabinets: Size and depths as noted on Drawings, with fire -retardant wood backboards. PART 3 - EXECUTION 3.01 INSTALLATION A. Install junction boxes so that covers are readily accessible after the completion of the installation. B. Mount rigidly in place with front of box level and plumb. C. Secure flush covers with corrosion resistant screws or bolts. D. Provide each pull box with sufficient clamps to which cables shall be secured in neat and orderly fashion permitting ready identification. E. Mount pull boxes connected to concealed conduits with covers flush with the finished wall. F. Neatly write each "panel - circuit" contained in each junction box on the cover with a permanent marker. ***END OF SECTION*** SECTION 16140 WIRING DEVICES PART1-GENERAL 1.01 WORK INCLUDED A. The work under this section includes wall switches, receptacles, occupancy sensors, wall dimmers, device plates and box covers, poke -through service fittings, access floor boxes, photocells and time clocks. PART 2 - PRODUCTS 2.01 DESCRIPTION A. WALL SWITCHES: 20-amp,120/277V commercial grade. Single pole (White): Leviton CS120-2W. 3-way (White): Leviton CS320-2W. 4-way (White): Leviton CS420-2W. 2-pole (White): Leviton CS220-2W. B. RECEPTACLES (multiple on a branch circuit): 15-amp, 120V commercial grade. Duplex (White): Leviton CR15-W. Duplex Tamper Resistant (White): Leviton CR15S-GW. C. RECEPTACLES (single duplex or simplex on a branch circuit): 20-amp,120V commercial grade. Duplex (White): Leviton CR20-W. Simplex (White): Leviton 5801-W. D. GFCI RECEPTACLES: 20-amp,120V commercial grade. Duplex (White): Leviton 7899-W. Receptacles serving vending machines and drinking fountains shall be GFCI type. E. GFCI RECEPTACLES: 20-amp,120V commercial grade, weather resistant. Duplex (White): Leviton W7899-W for all outdoor, cooler, freezer, and any other damp or wet locations. F. OCCUPANCY SENSORS (wall mounted): Dual technology, maximum load of 80OW at 120V or 120OW at 277V, Watt Stopper DW-100-W. Adjust for 15 minute time delay and appropriate sensitivity. G. OCCUPANCY SENSORS (ceiling mounted 10' AFF or less): Maximum load of 80OW at 120V or 120OW at 277V, Watt Stopper DT-355-W (DT-300-W with BZ150 power pack for low voltage applications). Adjust for 15 minute time delay and appropriate sensitivity. H. TIMER SWITCH: Digital adjustable with a range of 5 minutes to 12 hours. Maximum load of 80OW at 120V or 120OW at 277V, Watt Stopper TS-400. I. PHOTOCELL: Weatherproof, adjustable. Intermatic K4100 series. J. TIME CLOCK: Single or multi -circuit as indicated on the plans. Intermatic ET90000 series. PART 3 - EXECUTION 3.01 GENERAL A. All devices are to be installed in 4" square boxes, except when installed in masonry. B. Cover plates in commercial kitchens shall be type 302 stainless steel. All other cover plates shall be smooth white nylon unless otherwise specified herein. C. Cover plates for receptacles installed in damp or wet locations shall be weatherproof while -in -use. D. Cover plates for light switches in exterior, cooler, and freezer applications shall be equivalent to Carlon E98TSCN-CAR weatherproof cover. E. Note mounting heights indicated by the symbology and notes on the plans. F. All devices shall have a bonding pigtail conductor from grounding terminal to the metal box system (except IG). Self -grounding receptacles using mounting screws as bonding means are not approved. G. Except as otherwise indicated on the Drawings, mount devices flush, with long dimension vertical, and grounding pin on receptacles on bottom. Group adjacent switches and receptacles under a single, multi -gang wall plate. Where communications outlets are shown adjacent to power receptacles, both shall be installed at same elevation. ***END OF SECTION*** SECTION 16170 GROUNDING AND BONDING PART1-GENERAL 1.01 WORK INCLUDED A. Grounding electrodes and conductors, equipment grounding conductors and bonding. PART 2 - PRODUCTS 2.01 ROD ELECTRODE A. Material: Copper -clad steel. B. Diameter: 3/4" minimum. C. Length: 10' minimum. Rod shall be driven at least 9'-6" deep. D. Provide the number of rods required to obtain proper ground resistance. 2.02 MECHANICAL CONNECTORS A. The mechanical connector bodies shall be manufactured from high strength, high conductivity cast copper alloy material. Bolts, nuts, washers and lock washers shall be made of Silicon Bronze and supplied as a part of the connector body and shall be of the two bolt type. B. Split bolt connector types are NOT allowed. C. The connectors shall meet or exceed UL 467 and be clearly marked with the catalog number, conductor size and manufacturer. 2.03 COMPRESSION CONNECTORS A. The compression connectors shall be manufactured from pure wrought copper. The conductivity of this material shall be no less than 99% by IACS standards. B. The installation of the connectors shall be made with a compression, tool and die system, as recommended by the manufacturer of the connectors. C. The connectors shall be clearly marked with the manufacturer, catalog number, conductor size and the required compression tool settings. D. Each connector shall be factory filled with an oxide -inhibiting compound. 2.04 EXOTHERMIC CONNECTIONS A. WIRE 1. Material: Stranded copper (aluminum not permitted). 2. Grounding Electrode Conductor: Size as shown on drawings, specifications or as required by NFPA 70, whichever is larger. o w Q 0 co 0 a Y 0 U iedri�: k Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 m m w w a, Q) � o w r LnLn L 0 o00�� OH r�, U om�@ r" m o lLr) � Ln 0 z Ln m e 1V0. 58722 STr, (C �"'�O>�t Ai. .a�®ti p PR(),IFrT AnnRF.q:R, CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY. FL 33525 SPECIFICATIONS U PART 3 EXECUTION 3.01 GENERAL A. Install Products in accordance with manufacturer's instructions. B. Mechanical connections shall be accessible for inspection and checking. No insulation shall be installed over mechanical ground connections. C. Attach grounds permanently before permanent building service is energized. D. Install rod electrodes at "non -trip -hazard" locations indicated or as required by Code, whichever requires the most rods. Install additional rod electrodes as required to achieve specified resistance to ground. E. Provide bonding to meet NEC Requirements, including but not limited to bonding between telephone, television, and security systems. F. Coordinate with general contractor to insure at least (2) column anchor bolts are tied to footing steel rebar at column nearest electrical service using the usual steel tie wires. 3.02 FIELD QUALITY CONTROL A. Inspect grounding and bonding system conductors and connections for tightness and proper installation. B. Measure ground resistance from system grounding electrode connection at service entrance (neutral -ground bond removed) to earth ground reference point using suitable ground testing equipment. Resistance shall not exceed 25 ohms. ***END OF SECTION*** SECTION 16426 DISTRIBUTION EQUIPMENT PART1-GENERAL 1.01 WORK INCLUDED A. Standard and custom products equivalent to Square D, NQOD, NF, I -Line panelboards, and QMB switchboards, as well as safety switches, contactors, and starters. Cutler Hammer, Siemens, and GE are acceptable manufacturers. PART 2 - PRODUCTS 2.01 MATERIALS A. All distribution gear shall be fully bussed and fingered for all pole positions numbered on schedules. B. All distribution gear shall have a ground bus. C. For 4-wire systems, the neutral bus shall be the equivalent ampacity as the phase bus bars. D. Provide mechanically fastened permanent plastic nametag with 1/4"H letters indicating name of each switchboard, panelboard, and transformer as well as a permanent plastic nametag indicating each load fed for each switchboard. E. All panelboards and switchboards shall use bolt -on circuit breaker overcurrent devices. F. Provide circuit breakers UL listed as Type HACR for air conditioning equipment branch circuits. G. Do not use tandem circuit breakers. H. Safety switches used for service disconnecting means shall be Heavy Duty,100,000 AIC minimum. All others may be General Duty. I. Provide Class L fuses for individual motors, 50 hp and larger; Class J for service mains including tenant meter disconnects downstream of mains; Class RK5 fuses for all other applications. J. Refer to panel schedules for ampacities, voltage, phase, NEMA rating, mounting configuration, AIC rating, and accessories. K. Lighting contactors shall have 30 amp rated contacts, minimum. L. Provide a typewritten panel directory for each panelboard or loadcenter with sufficient detail to distinguish each circuit from all others within the panelboard or loadcenter. M. Sharing a neutral is permitted for up to three circuits, one per phase, of the same amp rating for 208Y/120V branch circuits on non -dimmed circuits. Where a shared neutral conductor is used for multiple branch circuits, contractor shall either group circuits together in panel and provide a manufacturer furnished and listed handle -tie to simultaneously trip all of the circuits sharing the neutral or provide multi -pole circuit breakers. Plans may not depict shared neutrals, but they are allowed in accordance with the above specification. N. All circuit breakers used for service disconnecting means,1,200 amps and larger, shall have electronic trip units equivalent to Square D MicroLogic 5.OH (6.OH where GFI is specified). Such breakers shall be accompanied with a factory installed phase failure relay, Taylor PND-###-T3 or equivalent. PART 3 - EXECUTION 3.01 INSTALLATION A. Install panelboards plumb with wall finishes with height 6-6" AFF to top. B. Provide filler plates for unused spaces in panelboards. C. Inspect for physical damage, proper alignment, anchorage, and grounding. Check proper installation and tightness of connections. D. Rigidly mount disconnects and starters adjacent to load served, maintaining working clearance required by NEC. E. Electrical equipment, such as switchboards, panelboards, industrial control panels, meter socket enclosures, and motor control centers, that are in other than dwelling occupancies, and are likely to require examination, adjustment, servicing, or maintenance while energized shall be field marked to warn qualified persons of potential electric arc flash hazards. Provide factory labels to comply. F. Where the area above the dedicated electrical space above electrical equipment contains systems which could leak or condensate, provide suitable protection to avoid damage to the electrical equipment. G. All floor mounted electrical gear is to be installed on 4" tall concrete housekeeping pads. ***END OF SECTION*** SECTION 16500 INTERIOR LIGHTING PART 1 - GENERAL 1.01 QUALITY ASSURANCE A. Comply with NEC requirements as applicable to wiring types and lengths for fixture whips. Provide lighting components and fittings that are UL-listed and labeled. PART 2 - PRODUCTS 2.01 MATERIALS A. Lighting fixtures shall be the type indicated on Drawings and as specified. Fixtures of same type shall be of identical make, design, and appearance. Size of lighting fixtures shall be as specified for the lamp or fixture wattage indicated on Drawings. Specific manufacturer and model number references are indicated as a standard of quality and other manufacturers may be supplied provided the product meets or exceeds the specifications. B. Ballasts shall comply with applicable state, federal and industry performance safety standards including FCC requirements governing electromagnetic and radio frequency interference, IEEE standards for line voltage transient protection and harmonic distortion. C. When occupancy sensors are controlling fluorescent fixtures, ballasts shall be programmed rapid start. Instant start is acceptable otherwise. D. Ballasts shall comply with 2008 NEC 410.130 (G) requirement for integral disconnecting means. E E. Provide lamps with lighting fixtures. Lamps shall be as manufactured by General Electric, Philips, Venture, or Sylvania. F. Fluorescent lamps shall be 3,000 lumen minimum, 841, 850 for fluorescent high -bays. PART 3 - EXECUTION 3.01 INSTALLATION A. Clean surfaces of dirt, cement, plaster and debris. Furnish cleansers compatible with material surfaces being cleaned. B. Replace defective lamps and ballasts. C. Support recessed fixtures in ceilings as follows: Fixtures shall be independently supported from structure above using (2) #12 ceiling tie -wires per fixture at diagonal corners. D. Recessed fixtures shall fit snugly against ceilings to prevent light leakage. E. Light fixtures and associated wiring shall be installed in accordance with NEC Article 410. F. Where supported via threaded means, all nuts shall be double nutted with lock -washers. ***END OF SECTION*** SECTION 16741 TELEPHONE AND DATA SYSTEM PART 1-GENERAL 1.01 QUALITY ASSURANCE A. Comply with applicable requirements of NEMA and UL standards. Provide products and components that have been UL listed and labeled. PART 2 - PRODUCTS 2.01 MATERIALS A. Outlet boxes shall consist of 4" square deep boxes. Provide minimum 2-1/4" deep boxes unless required otherwise by field conditions. B. Provide backboard in telephone equipment rooms consisting of 3/4" deep X T wide X 8' high AC plywood unless noted otherwise on plans. PART 3 - EXECUTION 3.01 INSTALLATION A. Provide minimum 1" conduits from outlet boxes to accessible space above ceiling, terminated with bushing. Where hard ceilings are installed, route conduit to nearest accessible location. B. Paint both sides of telephone backboards with 2 coats of fire retardant paint prior to installation. C. Use long sweep rigid 90-degree elbows on telephone service entrance conduits. D. Provide a ground bar at each telephone backboard location. Provide a #4 Green copper ground from each ground bar to main telephone systems ground or to building grounding electrode system. E. Provide a pull string in all conduits. ***END OF SECTION*** ELECTRICAL LEGEND SYMBOL DESCRIPTION MOUNTING SYMBOL DESCRIPTION MOUNTING O CEILING LIGHT FIXTURE. SEE FIXTURE SCHEDULE. DUPLEX RECEPTACLE. SEE SPECIFICATIONS. 18" AFF TO CENTERLINE UON. ® CEILING LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. DUPLEX RECEPTACLE, ABOVE COUNTER. SEE SPECIFICATIONS. 44" AFF TO CENTERLINE UON. O-- WALL WASH LIGHT FIXTURE. ARROW INDICATES WASH DIRECTION. SEE FIXTURE SCHEDULE. DUPLEX RECEPTACLE, ONE-HALF SWITCHED. SEE SPECIFICATIONS. 18" AFF TO CENTERLINE UON. 4 WALL BRACKET LIGHT FIXTURE. SEE FIXTURE SCHEDULE. ® DUPLEX RECEPTACLE, FLOOR OR POKE-THRU. SEE SPECIFICATIONS. FLUSH IN FLOOR UON. WALL BRACKET LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. DOUBLE DUPLEX RECEPTACLE. SEE SPECIFICATIONS. 18" AFF TO CENTERLINE UON. Q WALL BRACKET LIGHT FIXTURE. SEE FIXTURE SCHEDULE. DOUBLE DUPLEX RECEPTACLE, ABOVE COUNTER. SEE SPECIFICATIONS. 44" AFF TO CENTERLINE UON. WALL BRACKET LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. q) SIMPLEX RECEPTACLE. SEE SPECIFICATIONS. 18" AFF TO CENTERLINE UON. o WALL MOUNTED SCONCE LIGHT FIXTURE SEE FIXTURE SCHEDULE. CLOCK OUTLET 84" AFF TO CENTERLINE UON. WALL MOUNTED SCONCE LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. V SPECIAL RECEPTACLE. NEMA CONFIGURATION AS NOTED. 18" AFF TO CENTERLINE UON. C1 V X V LIGHT FIXTURE. SEE FIXTURE SCHEDULE. DUPLEX RECEPTACLE MOUNTED FLUSH IN CEILING. AS NOTED ® 1' X 1' LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. MULTI -OUTLET SURFACE RACEWAY WITH NEMA 5-15R SIMPLEX RECEPTACLES AT 12" CENTERS UON. 44" AFF TO CENTERLINE UON. ® FTX 2' LIGHT FIXTURE. SEE FIXTURE SCHEDULE. so 208Y/120V OR 240/120V PANELBOARD. 78" AFF TO TOP. Ual2' X 2' LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. am 277Y/480V PANELBOARD. 78" AFF TO TOP. 2' X 4' LIGHT FIXTURE. SEE FIXTURE SCHEDULE. ,= DISCONNECT SWITCH. NEMA/AMPS/POLE/FUSE/VOLTAGE. PROVIDE NEMA 1, 600V UON. AS NOTED. 2' X T LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. m MOTOR STARTER. AS NOTED. 0 SURFACE MOUNTED LIGHT FIXTURE. SEE FIXTURE SCHEDULE. ZP COMBINATION MOTOR STARTER/DISCONNECT SWITCH. NEMA/AMPS/POLE/FUSE/VOLTAGE. PROVIDE NEMA 1, 600V UON. AS NOTED. SURFACE MOUNTED LIGHT FIXTURE WITH EMERGENCY POWER BACKUP SEE FIXTURE SCHEDULE. MMC]J ELECTRIC DUCT HEATER. BY OTHERS. WALL MOUNTED LIGHT FIXTURE. SEE FIXTURE SCHEDULE. N MOTOR CONNECTION OR EXHAUST FAN. BY OTHERS. WALL MOUNTED LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. © POWER POLE WITH POWER AND COMMUNICATIONS RACEWAY PROVISIONS AS NOTED. AS NOTED. I--�—I FLUORESCENT STRIP LIGHT FIXTURE. SEE FIXTURE SCHEDULE. v COMMUNICATIONS/DATA OUTLET. 18" AFF TO CENTERLINE UON. FLUORESCENT STRIP LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. SEE FIXTURE SCHEDULE. ® COMMUNICATIONS/DATA OUTLET, FLOOR OR POKE-THRU. FLUSH IN FLOOR UON. 00-- FLOOD LIGHT FIXTURE. SEE FIXTURE SCHEDULE. ® COMBINATION COMMUNICATIONS/DATA AND DUPLEX RECEPTACLE OUTLET, FLOOR BOX. FLUSH IN FLOOR UON. TRACK LIGHT FIXTURE (STRAIGHT). SEE FIXTURE SCHEDULE. ® COMBINATION COMMUNICATIONS/DATA AND QUAD RECEPTACLE OUTLET, FIRE RATED POKE-THRU. FLUSH IN FLOOR UON. �-�- TRACK LIGHT FIXTURE (CURVED). SEE FIXTURE SCHEDULE. P p FURNITURE SYSTEM BASE FEED (POWER AND DATA), REFER TO NOTES AND SPECIFICATIONS. AS NOTED. PENDANT MOUNTED LIGHT FIXTURE. SEE FIXTURE SCHEDULE. CABLE TV OUTLET. 18" AFF TO CENTERLINE UON. ACCENT LIGHT FIXTURE. SEE FIXTURE SCHEDULE. 4 SECURITY SYSTEM CARD READER OUTLET. 48" AFF TO CENTERLINE UON. �1lP CEILING FAN. SEE FIXTURE SCHEDULE. OQ SECURITY SYSTEM CLOSED CIRCUIT TV CAMERA. AS NOTED. ® SINGLE -FACE CEILING MOUNTED EXIT SIGN WITH AIMING ARROWS AS INDICATED. FILL REPRESENTS READABLE FACE DIRECTION. SEE FIXTURE SCHEDULE. ® FIRE ALARM SYSTEM CONTROL PANEL. 78" AFF TO TOP. TWO -FACE CEILING MOUNTED EXIT SIGN WITH AIMING ARROWS AS INDICATED. FILL REPRESENTS READABLE FACE DIRECTION. SEE FIXTURE SCHEDULE. ® FIRE ALARM SYSTEM REMOTE ANNUNCIATOR PANEL. 66" AFF TO TOP. WALL MOUNTED EXIT SIGN WITH AIMING ARROWS AS INDICATED. FILL REPRESENTS READABLE FACE DIRECTION. SEE FIXTURE SCHEDULE. Q2 FIRE ALARM SYSTEM SMOKE DETECTOR. CEILING UON. WALL MOUNTED EMERGENCY BATTERY PACK LIGHT FIXTURE. SEE FIXTURE SCHEDULE. � FIRE ALARM SYSTEM DUCT TYPE SMOKE DETECTOR. IN SUPPLY DUCT > 2,000 CFMIN RETURN DUCT > 15,000 CFM COMBINATION EMERGENCY BATTERY LIGHT AND EXIT SIGN WITH AIMING ARROWS AS INDICATED. FILL REPRESENTS READABLE FACE. SEE FIXTURE SCHEDULE. 4 DUCT SMOKE DETECTOR REMOTE TEST STATION. 66" AFF TO CENTERLINE UON. O{]-- POLE MOUNTED LIGHT FIXTURE, ARROW INDICATES OPTICS AIMING. SEE FIXTURE SCHEDULE. © FIRE ALARM SYSTEM HEAT DETECTOR. CEILING UON. SINGLE -POLE TOGGLE OR AUTOMATIC SWITCH. 48" AFF TO CENTERLINE UON. Q FIRE ALARM SYSTEM PULL STATION. 48" AFF TO CENTERLINE UON. TWO -POLE TOGGLE SWITCH. 48" AFF TO CENTERLINE UON: rs FIRE ALARM SYSTEM TAMPER SWITCH. FIELD COORDINATE. THREE-WAY TOGGLE OR AUTOMATIC SWITCH. 48" AFF TO CENTERLINE UON. rs FIRE ALARM SYSTEM FLOW SWITCH. FIELD COORDINATE. ` FOUR-WAY TOGGLE OR AUTOMATIC SWITCH. 48" AFF TO CENTERLINE UON. ® FIRE ALARM SYSTEM RELAY CONTROL MODULE. FIELD COORDINATE. ° OCCUPANCY SENSOR SWITCH. 48" AFF TO CENTERLINE UON. 0 FIRE ALARM SYSTEM MONITORING MODULE. FIELD COORDINATE. OM MOMENTARY CONTACT TOGGLE SWITCH. 48" AFF TO CENTERLINE UON. ❑D FIRE ALARM SYSTEM MAGNETIC DOOR HOLDER. ON WALL 6" BELOW TOP OF DOOR. OT TIMER SWITCH. 48" AFF TO CENTERLINE UON. FIRE ALARM SYSTEM HORN. 80" AFF TO BOTTOM. �soo DIMMER SWITCH. PROVIDE WATTAGE RATING INDICATED. F DENOTES FLUORESCENT DIMMER. 48" AFF TO CENTERLINE UON. ® FIRE ALARM SYSTEM STROBE, 75 CANDELA UON. 80" AFF TO BOTTOM. CEILING MOUNTED OCCUPANCY SENSOR SWITCH. CEILING UON. FIRE ALARM SYSTEM HORN/STROBE, 75 CANDELA UON. 80" AFF TO BOTTOM. J2) it JUNCTION BOX OR OUTLET BOX. AS NOTED. FIRE ALARM SYSTEM CEILING MOUNTED HORN/STROBE, CANDELA UON. 30' MAX MOUNTING HEIGHT. SURFACE ON CEILING. �II, GROUND ROD. AS NOTED. MM FIRE ALARM SYSTEM MINI -HORN. 80" AFF TO BOTTOM. CONDUIT CONCEALED IN WALL OR ABOVE CEILING. SEE SPECIFICATIONS. R FIRE ALARM SYSTEM BELL. 96" AFF TO TOP UON. _ � CONDUIT CONCEALED IN SLAB OR UNDERGROUND. SEE SPECIFICATIONS. o • UP DN CONDUIT RUN UP OR DOWN AS NOTED. ------- CONDUIT EXPOSED ON WALL OR CEILING. SEE SPECIFICATIONS. PHASE, NEUTRAL, EQUIPMENT GROUND, AND ISOLATED GROUND. ALL HOMERUNS SHALL BE MINIMUM 1/2" CONDUIT WITH 3 #12, UON. LINE SHADING FOR EXISTING ELECTRICAL © PC TIME CLOCK / PHOTOCELL LINE SHADING FOR NEW ELECTRICAL O O REFER TO KEYED NOTES. ABBREVIATIONS ABBREVIATIONS AFF ABOVE FINISHED FLOOR. HID HIGH INTENSITY DISCHARGE. AFG ABOVE FINISHED GRADE. HP HORSEPOWER. ATS AUTOMATIC TRANSFER SWITCH. IG ISOLATED GROUND. BFG BELOW FINISH GRADE. LCP LIGHTING CONTROL PANEL C CONDUIT. LSIG LONG, SHORT, INSTANTANEOUS & GROUND FAULT TRIP SETTINGS (ALL ADJUSTABLE). CLG CEILING MOUNTED. N NEW. D DEMOLITION NEUT NEUTRAL. DN CONDUIT DOWN. NF NON -FUSED. E EXISTING. NL NIGHT LIGHT. EC ELECTRICAL CONTRACTOR. NP NAMEPLATE. EG EQUIPMENT GROUND. OFCI OWNER FURNISHED, CONTRACTOR INSTALLED. EXP EXPLOSION PROOF. PNL PANEL. EWC ELECTRIC WATER COOLER. RE RELOCATED. EWH ELECTRIC WATER HEATER. UON UNLESS OTHERWISE NOTED. GEC GROUNDING ELECTRODE CONDUCTOR. UPS NINTERRUPTIBLE POWER SUPPLY. GFI GROUND FAULT INTERRUPTER (BREAKER) / GROUND FAULT CIRCUIT INTERRRUPTER (RECEPTACLE). WP WEATHERPROOF. FTL FEED THRU LUGS (FEED DOWNSTREAM SECTION WITH IDENTICAL FEEDER AS PREVIOUS SECTION) I XFMR TRANSFORMER THE DESIGN FLOOD ELEVATION IS 12" AFF, UON. rgr�c� 11111111111 0 W Q 0 Q x cD 0 G. H LU D a W z 0 0 W Z F W W m J J a WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 r- rr�� m w U a, � o w Ln r Cc Ln �or�00t 0 V oN COa 0 lI� � � w Ln 0 z Ln 00 m 01 Vk No,58722 STATP OF a` ra0NaeeaiV`'00 Qi LO co > co Q _I LL < 4-a LO J J PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 JIM DATE I DESCRIPTION I LEGEND, SFEC'S CONTINUED MDO PROJECT #: 14-87 ��1 LIGHTING NOTES O 1. EXISTING FIXTURE TO BE RELOCATED TO POSITION SHOWN AND RE -CIRCUITED AS NOTED. 2. EXISTING FIXTURE TO BE RELOCATED TO POSITION SHOWN, PROVIDE NEW 1100 LUMEN MIN. EMERGENCY BATTERY BALLAST AND RECIRCUIT AS NOTED. 3. CONNECT EXIT LIGHT TO UNSWITCHED HOT LEG OF LOCAL LIGHTING CIRCUIT. 4. CONNECT EMERGENCY BATTERY BALLAST TO UNSWITCHED HOT LEG OF LIGHTING CIRCUIT. 5. ROUTE HOMERUN FOR SIGN CIRCUIT VIA TIME CLOCK. PROVIDE TORK MODEL 7100 (OR EQUIVALENT) TIME CLOCK MOUNTED ADJACENT TO PANEL. 6. SHOW WINDOW RECEPTACLE ABOVE WINDOW, TYP. 7. WALL MOUNTED, DUAL TECHNOLOGY, LINE VOLTAGE OCCUPANCY SENSOR EQUAL TO WATT STOPPER #DW-100. 8. POWER PACK FOR LOW -VOLTAGE OCCUPANCY SENSORS, UP TO 225mA SENSOR LOAD PER POWER PACK. POWER PACK EQUIVALENT TO WATT BZ150 (120/277V). 9. CEILING/PENDANT MOUNTED OCCUPANCY SENSOR, LOW VOLTAGE, EQUIVALENT TO WATT STOPPER DT-300 (431rnA), WIRED TO POWER PACK. 10. CEILING MOUNTED, DUAL TECHNOLOGY, LINE VOLTAGE OCCUPANCY SENSOR EQUAL TO WATT STOPPER #DT-355. 11. TOGGLE SWITCH TO BE WIRED TO LOAD SIDE OF OCCUPANCY SENSOR FOR MANUAL "OFF" CONTROL. 12. JUNCTION BOX FOR SIGN, FIELD VERIFY EXACT LOCATION AND REQUIREMENTS WITH SIGN CONTRACTOR. GENERAL NOTES 1. ALL 120V CIRCUIT LENGTHS GREATER THAN 100 FT SHALL BE INCREASED TO #10 AWG AND TO # 8 AWG WHEN GREATER THAN 160 FT. INCREASE CONDUIT SIZE FOR 40% FILL. 2. WHERE MORE CONDUCTORS ARE SHOWN THAN CIRCUITS, EXTRA HOT CONDUCTOR IS FOR EMERGENCY BATTERY BALLAST AND/OR NIGHT LIGHTS AND SHALL NOT BE SWITCHED. U 3. WHERE A SHARED NEUTRAL CONDUCTOR IS USED FOR MULTIPLE BRANCH CIRCUITS, CONTRACTOR SHALL GROUP CIRCUITS TOGETHER IN PANEL AND PROVIDE A MANUFACTURER FURNISHED HANDLE -TIE TO SIMULTANEOUSLY TRIP ALL OF THE CIRCUITS SHARING THE NEUTRAL. 4. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA ENERGY CONSERVATION CODE 505.7.3 HAS BEEN TAKEN INTO ACCOUNT FOR THIS PROJECT. FIXTURE SCHEDULE SYMBOL MANUFACTURER MODEL NUMBER LAMPS MOUNTING FIXTURE WATTAGE DESCRIPTION METALUX 2GR8-332-A125-120-EB81 HUBBELL EQUIVALENT (3) 32W T8, 3,000 2' x 4', FLUORESCENT TROFFER WITH 0.125" ACRYLIC A LITHONIA EQUIVALENT LUMEN MIN RECESSED 81W LENS, 120V. PHILIPS EQUIVALENT METALUX 2GR8-332-A125-120-EB81-EL HUBBELL EQUIVALENT (3) 32W T8, 3,000 SAME AS TYPE 'A', EXCEPT WITH 1100 LUMEN 90 MIN. AE RECESSED 81W LITHONIA EQUIVALENT LUMEN MIN BATTERY BALLAST. PHILIPS EQUIVALENT EXISTING EXISTING (3) 32W T8, 3,000 KE LUMEN MIN RECESSED 81W 2' x 4', 18 CELL FLUORESCENT PARABOLIC TROFFER,120V. PORTFOLIO LD615D010-ERM6835-6LMl-LI OMEGA EQUIVALENT 1500 LUMEN RECESSED IN 6" DIAM. LED DIMMABLE DOWNLIGHT,120V. UL LISTED D LITHONIA EQUIVALENT LED CEILING 25W FOR PROTECTED WET LOCATIONS. PROVIDE MATCHING DIMMER SWITCH WHERE NOTED. PHILIPS EQUIVALENT HALO L7R-104-P-LZR200-DE112 W/(#) HUBBELL LZR404P HEADS TR 50W MR16 CEILING 50W TRACK LIGHTING, QTY HEADS SHOWN, 120V LITHONIA PHILIPS LUMARK XTORIA HUBBELL EQUIVALENT 734 LUMEN LED SURFACE ON LED FULL CUTOFF WALL LIGHT, COLOR SELECTION BY W1 LITHONIA EQUIVALENT BY MFR WALL AT 8'-0" 8W OTHERS, 120V. PHILIPS EQUIVALENT SURE-LITES LPX-70-RWH HUBBELL EQUIVALENT SURFACE ON UNIVERSAL LED EXIT SIGN WITH INTEGRAL 90 MIN. X L.E.D. WALL 6" ABOVE 1W LITHONIA EQUIVALENT BATTERY BACKUP, 120V. DOOR PHILIPS EQUIVALENT M0 LIGHTING PLAN m w Q 0 a x c� of 0 0 U) D 0 Z 0 a 0 z Lu cc W m J J Q Ahl Architectui WIEDRICK ARCHITECTURE INC AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 m w Z H o O Q o � v 00 ,n o x h co o lu O , XLn 4 1 1) � �� �• w w Ll 1 Q Ln 00 O ON � w CV '4 Lo C'7 Q J LL < rl Lo _--1 i N PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 rl IPNT- FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 DATE I DESCRIPTION 2/17/14 1 REV 01 OWNER CHANGES LIGHTING PLAN MDO PROJECT #: 14-87 E10�1 r 10/15/14 1 POWER NOTES O 1. PROVIDE TX TX 3/4" FIRE RETARDANT PAINTED PLYWOOD TELEPHONE BACKBOARD WITH TOP AT T AFF. EXTEND #6 CU FROM BACKBOARD TO GROUNDING ELECTRODE SYSTEM. EXTEND 1"C WITH PULLWIRE TO EXISTING TEL. SVC PNL LOCATED IN RM 120. 2. PROVIDE WIREMOLD SERIES ALA4800 TWO CHANNEL SATIN ANODIZED AL WIREWAY WITH OUTLETS 18" ON CENTER (TOP CHANNEL MOUNT). LOWER CHANNEL FOR DATA CABLES. 3. N3R/60/3/60/240V DISCONNECT FOR DISHWASHER. 4. PROVIDE JUNCTION BOX WITH 120V CIRCUIT AS INDICATED ABOVE DOOR. Q ( I 5. 3 #4 & 1 #10EG,1-1/4"C. on m 6. MAKE FINAL CONNECTION TO DISHWASHER WITH SEALTITE FLEX. GENERAL NOTES 1. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. 2. ALL GROUNDING ELECTRODE SYSTEMS SHALL BE INTERCONNECTED PER NEC 250.52. 3. ALL 120V CIRCUIT LENGTHS GREATER THAN 100 FT SHALL BE INCREASED TO #10 AWG AND TO # 8 AWG WHEN GREATER THAN 160 FT. INCREASE CONDUIT SIZE FOR 40% FILL. 4. REFER TO HVAC WIRING SCHEDULE FOR CIRCUITING REQUIREMENTS OF SAME. 5. WORKING CLEARANCE SHALL BE AFFORDED TO ALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC 110.26. 6. ALL 15 & 20A,120V RECEPTACLES WITHIN 6FT OF A SINK SHALL BE GFCI PROTECTED. 7. WHERE A SHARED NEUTRAL CONDUCTOR IS USED FOR MULTIPLE BRANCH CIRCUITS, CONTRACTOR SHALL GROUP CIRCUITS TOGETHER IN PANEL AND PROVIDE A MANUFACTURER FURNISHED HANDLE -TIE TO SIMULTANEOUSLY TRIP ALL OF THE CIRCUITS SHARING THE NEUTRAL. 8. WHERE COMMUNICATIONS OUTLETS ARE SHOWN ADJACENT TO POWER RECEPTACLES, BOTH SHALL BE INSTALLED AT THE SAME ELEVATION. 9. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA ENERGY CONSERVATION CODE 505.7.3 HAS BEEN TAKEN INTO ACCOUNT FOR THIS PROJECT. POWER FLAN 3/161I-1'_0II 0 Lu Q 0 Q c� a a 0 U co w C1 w Z 0 0 z D Lu w w m J Q H �eCIFICK - Architecture, Inc. WIEDRICK ARCHITECTURE INC, AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736,8627 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 m w � O w aLn Ln w 5 n 0 5 Ln 00 s~ 0 z 00 m cq� •�� ,,�,{.a , 4ss fir. M V �A No. 58722 `) STATE OF ' t • � BB�Blf§6{Risea� 0 N d- 43 cB7 > cy-) J LL y lid mom PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 (`I IF-:I\IT- FLORI DA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 0DATE DESCRIPTION 2/17/14 REV 01 OWNER CHANGES FOIUER PLAN MDO PROJECT #: 14-87 F n, r- 10/15/14 �� Iv �Um ®® fifi� � T Vie 1� dui 12 5 d System No. W-L-1049 F Ratings -1 and 2 Hr (See Item 1) T Rating -0 Hr L Rating At Ambient -Less Than 1 CFM/sq ft L Rating At 400 F -Less Than 1 CFM/sq ft I —No- A Section A -A Wall Assembly -The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 3-518 3-1/2 in. (89 mm) wide and spaced max 24 in. (610 mm) OC. When steel studs are used and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed between the vertical studs and screw -attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. (102 to 152 mm) wider and 4 to 6 in. (102 to 152 mm) higher than the diam of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 in. (51 to 76 mm) clearance is present between the penetrating item and the framing on all four sides. B. Gypsum Board* -5/8 in. (16 mm) thick, 4 ft (1.22 m) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 26 in. (660 mm) for steel stud walls. Max diam of opening is 14-1/2 in. (368 mm) for wood stud walls. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 1A. Metallic Sleeve -(Optional, Not Shown) - Cylindrical sleeve fabricated from min 0.016 in. (0.41 mm) to max 0.105 in. (2.7 mm) thick sheet steel. Length of steel sleeve to be equal to the thickness of wall. Longitudinal seam of sleeve welded or overlapped min 1 in. (25 mm). The ends of the steel sleeve shall be flush or recessed max 1/4 in. (6 mm) from wall surfaces. 2. Through Penetrant -One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. The annular space between pipe, conduit or tubing and periphery of opening shall be min 0 in. (0 mm, point contact) to max 2 in. (51 mm). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe -Nom 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe -Nom 24 in. (610 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit -Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing, nom 6 in. (152 mm) diam (or smaller) steel conduit or nom 1 in. (25 mm) diam (or smaller) flexible steel conduit. D. Copper Tubing -Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe -Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* -Sealant -Min 5/8 in. (16 mm) thickness of fill material applied within annulus, flush with both surfaces of wall. At the point contact location between through penetrant and gypsum board, a min 3/8 in. (10 rpm) diam bead of fill material shall be applied at the gypsum board/through penetrant interface on both surfaces of wall. SPECIFIED TECHNOLOGIES INC -SpecSeal Series SSS Sealant or SpecSeal LCI Sealant *Bearing the UL Classification Mark — - = Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. STI Created or Revised: December 14,2010 W-L-1049 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Maii:techserv@stifirestop.com • Website:www.stifirestop.com PAGE 1 OF 1 0 Uj 0 Q r 0 rK 0 0 U F— Li W 0 0 W Z 0 a- 0 Z 71 i_ W w co J Q 2 H u F "n �7 kedfick WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 727.736.8627 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 N LO m Mi cv � a w z v z ,—� v o W v U Ln H W o �'L"�)' `0 � o x H o cc �J —01 ID 'U ; m o w O w X [~ �-it�w v) w u' U o p 00 O n w 0 \ S ° No. 58722 UP :l STATE OF N' ��f81&ece[i'1�106E C\I � cL i M ® QJ -+- a co I 0�lid 'ql- J WItt Q� � _ M-4 PROJECT ADDRESS: 38444 5TH AVE. ZEPHYRHILLS, FL 33542 CLIENT: r FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 L DADE CITY, FL 33525 J 7 DATE DESCRIPTION 0 / 2/17/14 I REV 01 OWNER CHANGES F z: 0 jeFi Architecture, Inc. WIEDRICK ARCHITECTURE INC. AA26001799 2020 HEIDELBERG AVE. DUNEDIN, FLORIDA, 34698 STATE OF FLORIDA PROFESSIONAL ENGINEER: MATTHEW OTTO PE 58722 UEN ' Ic58792 jyj f ,T,"" -- OF isv/flK Al o�°v PRn.IF(-:T AnnRF.q.q° ,50444 ) I ti AVC. ZEPHYRHILLS, FL 33542 CLIENT: FLORIDA PHARMACY SOLUTIONS, INC. 13933 17TH ST. SUITE 300 DADE CITY, FL 33525 FOUJER R15ER DIAGRAM s SCHEDULES MU() PROJECT # —WAPkb ifi