HomeMy WebLinkAbout39740 Meadowood Lpn
REAR ELEVATION 1/411 = 11 011
12
I �
12" OH
EXISTING
HOUSE
1/0" STUCCO FINISH
-- - - - -- ------------- - -- - --
-- - - - - - - -
LEFT ELEVATION 1/411 _ 11 OII
12" OW
/EXISTING
HOUSE
i
1/91" STUCCO FINISH
-----------------
RIGHT ELEVATION 1/411 = 11 011
THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE
AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND
EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE
PROJECT, THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION
DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF
REPAIRS OR DELAY TO THE CONSTRUCTION
--------------EXISTING --------------
LIVING ROOM
I I
FOUNDATION FLAN 1/411 = 11 011
— — — — — — — — — — — — — — — — — — —
EXISTING
3" RECEIVER CHANNEL ATTACHED TO
ROOF PANEL FLAN 1/411 _ 11 011
PRODCUT CATEGORY
APPROVED PRODCUT LIST
SUB CATEGORYAPPROVAL MANUFACTURER
STATE V AL FL
STRUCTURAL COMPONET
LSTA20
SIMPSON
FL 10852
ROOFING
ROOF PANELS
METALS U.S.A.
FL I"nS.2
WINDOWS
SINGLE HUING
FLORIDA EXTRUDERS INC
FL S262.1
MILESTONE WOW
EXTERIOR DOORS
SINGLE SWINGING
PLAST PRO
FL 4164.1
I•
NO HEADER REQUIRED OVER OPENING
ON THIS WALL, BALLOON FRAME WALL
FROM SLAB TO BOTTOM OF ROOF PANELS
SIMPSON LTT205 ANCHOR WITH 5/S"Xl" RED
HEAD EXPANSION BOLT SECURE TO SLAB
THROUGH BOTTOM PLATE. FILL NAIL HOLES
TO STUDS WITH IODXI 1/2" NAILS
EXISTING
LIVING ROOM
SECURE WOOD WALLS TO BLOCK WALL AT
EACH OF THESE LOCATIONS WITH (4) 1/2"X4"
REDHEAD EXPANSION BOLTS EQUALLY
SPACED
EXISTING DOOR
NEW
FAMILY ROOM
35 SH
4' S"
14' O"
FLOOR FLAN 1/411 = I 011
ALL WALL$ ACT AS SHEAR WALLS
7
NO HEADER REQUIRED OVER OPENING
ON THIS WALL, BALLOON FRAME WALL
FROM SLAB TO BOTTOM OF F.00F PANELS
THESE ADDITION CONSTRUCTION DRAWINGS WERE DESIGNED TO COMPLY
WITH ALL OF THE LOADING REQUIREMENTS OF " SECTION S03 - STRUCTURAL"
OF THE FLORIDA BUILDING CODE 2001 - EXISTING BUILDING AND 2009
SUPPLEMENTS
EXISTING
LIVING: ROOM
I
ELECTRICAL PLAN 1/411 = 11 011
ELECTRICAL LEGEND
A.F.I. 110 V EXTERIOR DBL FLOOD
SWITCH �-I� ARC FAULT
(tb RECEPTACLE
110 V IIOV LIGHT
CAN BE CEILING
OR WALL (TYP)
ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT
EXTERIOR LOCATIONS BNALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT
ALL REMAINING OUTLETS IN HOME TO WIRED INTO A ARC -FAULT INTERRUPTER "AFI" CIRCUIT
SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT
TO BEDROOM AND OTHER LIVING AREAS
CARBON MONOXIDE ALARM MUST BE INSTALL WITHIN IOb" OF EACH ROOM USED FOR SLEEPING PURPOSES
WHEN BUILDING WAS A FOSSIL FUEL BURNING HEATER OR APPLIANCE, A FIREPLACE OR AN ATTACHED
GARAGE.
GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C.
3 g -74 0 �kajoa�
Rlivil5w
CITY OF
FLANS E
I
hI_4tvl-n I ALA.
I . 1� 1 I� T�
1�s•.I:L0R1L�A UiLD���J
LCTI.IC CGDL
y of
I HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED
DESIGNS AND FOUND IT TO BE IN COMPLIANCE WITH CHAPTER
16, SECTION 1609 OF THE FLORIDA BUILDING CODE FOR 120 MPH
(3 SECOND GUST) WIND ZONE - 100 MPH FASTEST SPEED AND THE
ENTIRE 2001 FLORIDA BUILDING CODE, RESIDENTIAL AND ALL
200% SUPPLEMENTALB
—C*
t.L. HANSON P.E. LICENSE NO, 3S654
P.O. BOX 1128, DADE CITY, FL 33526
by
2
tR
W.
G
?�O
NN.rI
Z��M v �
Q
Q
yz�o�H
gjvN`�Z
HQ
Q IN W
M
an
1 w
Z z� �� Zq
3 U oz o
ziy-
~ 0j5
- N
U
0
N
QC
z _ 0
o �
LL
0 �
A
TOTAL AREA
140 $CE. FT,
FIG
1 C')� 2
4
I
GENERAL NOTES:
THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2001 FLORIDA BUILDING CODE
RESIDENTIAL AND 2009 SUPPLEMENTS
T.L, I4ANSON 4 ASSOCIATES A REGISTERED LICENSED, FLORIDA PROFESSIONAL
ENGINEERING COMPANYs HAS APPLIED " RATIONAL ANALYSIS" FOR THE STRUCTURAL
DESIGN OF THIS STRUCTURE
THE BUILDING l INCLUDING ALL COMPONENTS AND CLADDINGS SHALL BE DESIGNED FOR THE
FOLLOWING SUPERIMPOSED LOADS
FLOORS,
LIVE LOADS - 40 P.B.F.
DEAD LOADS - 10 P,S,F.
GARAGE SLAB+
LIVE LOADS - 50 P.S,F.
DEAD LOADS - 10 P,S,F,
ROOPI
LIVE LOADS (TRUSS TOP CORD) - 20 P.S.F.
DEAD LOADS (TRUSS TOP CORD) - 10 P.S.F. 18 P.S.F. WHEN TILE ROOF INSTALLED
DEAD LOAD (TRUSS BOTTOM CORD) - 10 P.S.F.
ASSUMED TRUSS SELF WEIGHT ( DEAD LOAD) - 1 P,B,F.
WIND DESIGN ASSUMPTIONSs
WIND SPEED 120 MPH
BUILDING EXPOSURE - B
BUILDING IMPORTANCE FACTOR ■ 1.0
MEAN ROOF HEIGHT 30' OR LESS
HEIGHT 4 EXPOSURE ADJUSTMENTS COEFFICIENT ■ 1,0
ENCLOSED BUILDING O t� �., " 4
INTERNAL PRESSURE COEFFICIENT ■ + / - 0,18
COMPONETS 4 CLADDING POP ROOF ■ 14.9/ WALL • 25,9/-34,1
OVERHANG • ,�
STUCCO THICKNES: (ol
OVER FRAME GABLE 1/8" STUCCO OVER FELT BACKED GALV
LATH
OVER MASONARY WALL 1/2" 2 COAT STUCCO
GABLE ENDS WITH SIDING BACK WITH 015 FELT
SOIL BEARING 4 COMPACTION:
THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF
2000 P.S.F,( MINIMUM ) THE CONTRACTOR/PROPERTY OWNER IS RESPONSIBLE FOR VERIFYING
THAT THE SOIL ON THE SITE 18 PROPERLY PREPARED AND COMPACTED SUCH THAT IT CAN
SUPPORT A 2000 P.S.F. FOUNDATION LOADING
T.L. HANSON 4 ASSOCIATES A REGISTERED LICENSED FLORIDA PROFESSIONAL
ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION
SITE NOR PERFORMING ANY SOIL TESTING
T.L. HANSON 4 ASSOCIATES SHALL NOT BE RESPONSIBLE FOR THE SITE SOIL ABILITY TO SUPPORT
THE BUILDING LOADS
FOUNDATION 4 SLAB - ON- GRADE NOTES :
BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS:,
ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED
SUCH THAT IT CAN ADEQUATELY SUPPORT A 2000 P.S.F. FOUNDATION LOADING, SLAB
$HALL BE PLACE OVER A 6 MIL VAPOR BARRIER ON CLEAN ADEQUATELY COMPACTED
AND TERMITE POISONED SOIL
CONCRETE UTILIZED IN THE FOUNDATION AND SLABS SHALL HAVE A MINIMUM 28 DAY
COMPRESSIVE STRENGTH OF 3000 P.S.F.
REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE
WITH ASTM A -615, LAP SPLICES, WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR
115 REBAR , 3C" FOR 06 REBAR 4 35" FOR 01 REBAR
PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER
FINAL SITE GRADING) THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE
EXACT STEMWALL HEIGHT BASE UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION
AND CONTACT ENGINEER WHEN MORE THAN 4 COURSE ARE REQUIRED
A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE
FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A
STRING STRECTED FROM MARKER TO MARKER TO VERIFY REQUIRED SET BACKS
MASONRY WALLS:
CONCRETE MASONRY UNIT SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90
AND SHALL HAVE MINIMUM F'M OF 1500 P.S.I.
MORTAR SHALL CONFORM TO ASTMC -210 AND SHALL BE EITHER TYPE M OR $
REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE
WITH ASTMA-615. LAP SPLICES WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR 65 REBAR
30" FOR 06 REBAR AND 35" FOR 01 REBAR,
GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE
OF 3/8" PLACED AT 8 TO 11 INCH SLUMP AND HAVE A MINI. IUM 28 DAY COMPRESSIVE STRENGTH OF
2000 P.S,i, ( WHEN TESTED PER ASTM C-1019 )
PROVIDE CLEAN OUT OPENINGS ( 12 60, IN. ) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN
THE GROUT POUR EXCEEDS 5 POT IN HEIGHT
SOIL TERMITE TREATMENT:
TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES
APPLIED TO SOIL, OR WOOD, BATING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR
USE AS PREVENTATIVE TREATMENT TO NEW CONSTRUCTION.
A CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED
PEST CONTROL COMPANY BEFORE A " CERTIFICATE OF OCCUPANCY WILL BE ISSUED, THE CERTIFICATE
SHALL- STATE: (PER FBC R320.1)
THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN
TERMITES, THE TREATMENT IS INACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT
OF AGRICULTURE AND CONSUMERS SERVICES
IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION
SECTION R320,1 THROUGH R320.1.6 DO NOT APPLY. A SIGNED FIvER EYAR CONTRACT FROM THE ISSUE
OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION. MAINTENANCE AND MONITORING OF THE
BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE $LAB POUR. THE SYSTEM
MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL l PER FBC R320.11)
USE (U 6IMP60N LTT205 ANCHOR AT EACH
SIDE OF ALL DOOR AND WINDOW OPENINGS.
SECURE TO GLAD THROUGH DOTTOM PLATE
USING (1) 518"Xi" (I/2" DOLT SIZE ) RED HEAD
EXPANSION COLTS WITH A 1/2" X 2" SQUARE
WASHER AND TIGHTEN DOWN TO &LAB. FILL
ALL NAIL HOLES TO STUDS USING IODXI 1/2"
NAILS I
THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE
AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND
EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE
PROJECT, THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION
DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR CO&T OF
REPAIRS OR DELAY TO THE CONSTRUCTION
INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION
BACKFILLING 4 COMPACTION ARE COMPLETE f PER FBC 320.1.2.)
ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE- TREATED
INCLUDING ANY BOX OR FORMED AREAS ( PER FBC R320,1,2)
BOXED AREA IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE
WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF AN
ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE
INITIAL TREATMENT ( PER FBC R320,1,3)
A MINIMUM 6 MILL VAPOR BARRIER MUST BE INSTALL TO PROTECT AGAINST RAINFALL
DILUTION IF RAINFALL OCCUR$ BEFORE VAPOR BARRIER PLACEMENT, RE TREATMENT SHALL
BE REQUIRED (PER FBC R320,1,4)
ANY CONCRETE OVERPOUR , MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION
PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT, ( PER FBC R320,115)
EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE
WITHIN 12" OF THE STRUCTURE SIDE WALLS (PER FBC R320.1.6)
AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION 18
COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) ANY SOIL DISTURBED AFTER THE
VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED (PER FBC R32016)
CONDENSATE AND ROOF DOWN SPOUTS DISCHARGE AT LEAST 12" AWAY FROM THE BUILDING
A01M 4r;9 AdRRR&=Mft0V ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM
BELOW AND WITH IN 12" OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES TUB
TRAP BOXES, FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS
PER (FBC R320,8,3.)
THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONSs PAINT AND DECORATIVE
CEMENTITIOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL)
AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6" TO ALLOW FOR INSPECTION FOR FUTURE
TERMITE INFESTATIONS (PER FBC R104)
EXTERIOR WINDOWS 4 DOORS:
ALL EXTERIOR WINDOWS 4 GLASS DOORS OR ENTRANCE DOOR SHALL BE TESTED IN ACCORDANCE WITH
ANSI/AMMA/NWWDA 101/162 STANDARD AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURE
PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY
ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TEST OR ENGINEERED TO TRANSFER
1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE
INSTALL ALL WINDOWS AND DOOR ASSEMBLIES PER THE MANUFACTURE ANCHORING RECOMMENDATIONS
TO ACHIEVE THE DESIGN PRESSURES SPECIFIED
ELECTRICAL, PLUMBING, 4 MECHANICAL:
IN ACCORDANCE WITH CHAPTER 411.003 (2) (1) OF THE FLORIDA ADMINISTRATIVE CODES ELECTRICAL
PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO
MAST ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HERON
ARE BASE UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS.
ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT
EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "Gm" CIRCUIT
ALL ELECTRICAL OUTLETS IN BEDROOMS 4 FIXTURES SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER
"API" CIRCUIT
SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT
TO BEDROOM AND OTHER LIVING AREAS
GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N,E,C.
DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR
CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL
BE CONSTRUCTED OF MINIMUM NO,26 GAUGE SHEET STEEL OR
OTHER APPROVED MATERIALS AND SHALL HAVE NO OPENINGS
INTO THE GARAGE ( FBC 2004 R309.1.1.)
SAFETY GLAZING:
THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATION FOR THE PURPOSE OF
GLAZING
(1) GLAZING IN SWING DOORS, FIXED AND SLIDING PANEL OF SLIDING DOORS
ASSEMBLIES
(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM
ROOMS, BATHTUBS AND SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL
ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS
THAN 60" ABOVE THE DRAIN INLET
(3) GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE
THE NEAREST VERTICAL EDGE IS WITHIN A 24" RADIUS OF THE DOOR IN A CLOSED
POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE FINISH FLOOR OR
WALKING SURFACE
(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL OTHER THAN THOSE LOCATIONS
DESCRIBED IN ITEM& (2) AND (3) ABOVE, THAT MEETS ALL OF THE FOLLOWING
(A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 50. FT.
(B) BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR
(C) TOP EDGE GREATER THAN 36" ABOVE THE FLOOR
(D) ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY
OF THE PLANE OF THE GLAZING
TIMBER MATERIALS:
LUMBER UTILI'=7) IN BOTTOM PLATE, TOP PLATES ,POST, STUDS PACKS AND BEAMS
SHALL BE 02 YELLOW PINE (OR BETTER)
EXTERIOR AND INTERIOR LOAD BEARING STUDS SHALL BE 02 SPRUCE ( OR BETTER)
ALL OTHER STUDS SHALL BE "STUD GRADE" SPRUCE SPACE 16" OC, ALL SPLICES AT
TOP PLATE MUST BE MINIMUM 4'0" AND NAILED 4" OC WITH 12D COMMON NAILS
EXTERIOR WALLS SHALL BE CONSTRUCTED WITH 1/2" PLYWOOD OR 1/16" O.S.B. ( 2-M-W RATING) NAILED
WITH 8D NAILS SPACE AT 3" OC ALONG ALL HORIZONTAL JOINTS AND EDGES, 6" OC ALONG ALL VERTICAL
JOINTS AND EDGES AND 12" OC ALONG ALL INTERMEDIATE STUDS
AT OPENINGS 5'0" WIDE OR LARGER STRAP HEADER BEAM TO THE HEADER STUDS WITH (2) USP OR SIMPSON
LSTA24 STRAP TIES AT EACH END OF HEADER BEAM, ANCHOR BOTTOM OF HEADER STUDS TO FOUNDATION
WITH USP OR SIMPSON HTTI6 TENSION TIE.
ANCHOR WOOD SHEAR WALLS SEGMENTS TO FOUNDATION WITH SIMPSON LTT2015 TENSION TIE AT EACH
END OF WALL SEGMENTS AND AT ANY WALL SEGMENT INTERSECTION ( BUILDING CORNERS)
ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH INS MUST BE COMPLETE, INSPECTED AND APPROVED
PRIOR TO REQUESTING THE FRAMING INSPECTION.
STRAP ALL HEADER& A& SHOWN WITH (2)
SIMPSON L8TA20 OR EQUAL FLAT STRAPS
AT EACH END, FILL NAIL HOLES WITH
IODX 11/2" NAIL&
WINDOW AND DOOR OPENINGS TO
HAvE (U STUD BELOW HEADER ON
OPENINGS LESS THAN 4'0" AND
(2) STUDS ON OPENING LARGER,
WITH DOUBLE JACK STUDS
STUD WALL PER PLAN
WALL/ HEADER DETAIL
NOT TO SCALE
Um
3" RECEIVER CHANNEL ATTACHED TO EXISTING ROOF FASCIA,
ATTACH TO FASCIA WITH 1/2"X2" LAGS BOLTS 12" OC, ATTACH
ROOF PANEL TO RECEIVER CHANNEL WITH 0IOX3/4" SDS SCREWS
4" OC AT TOP AND BOTTOM. CONTRACTOR TO VERIFY INTEGRITY
OF EXISTING FASCIA
3" X 48" .024 ELITE ROOF PANELS
1/4"X(o" SDS SCREW WITH NEO WASHERS
SPACED 8" OC INTO TOP PLATE OF WALL
DBL 2X4 02 SPRUCE TOP PLATE
DBL 2X6 02 PINE WITH 1/2"
PLYWOOD IN CENTER OVER
THIS OPENING ONLY
2X4 02 SPRUCE STUDS * Iro" OC
R-11 FIBERGLASS INSULATION
IN ALL EXTERIOR WALLS WITH
1/2" GYPSUM WALLBOARD ON
INTERIOR
SGL 2X4 P.T. 50TTOM PLATE
18"X12" MONO FOOTING WITH
(2) "5 REBAR ON CHAIRS
3000 PSI CONCRETE
ATTACH DOOR TO STUDS THROUGH WOOD
DOOR JAMB PER YOUR MANUFACTURES
INSTRUCTIONS TO MEET WIND LOAD AND
COMPRESSION RATINGS FOR YOUR JOB
LOCATION
CAULK DOOR PER YOUR
DOOR MANUFACTURE SPECIFIC
RECOMMENDATIONS TO MEET
WIND LOAD AND COMPRESSION
RATINGS FOR YOUR JOB LOCATION
I
TYPICAL HEADER
TYPICAL STUD WALL
WOOD DOOR ATTACHMENT DETAIL
NOT TO SCALE
DBL 2X4 "2
SPRUCE HEADER
12
I �
j
SECURE WOOD WALLS TO BLOCK WALL AT
EACH OF THESE LOCATIONS WITH (4) 1/2"X4"
REDHEAD EXPANSION BOLTS EQUALLY
SPACED
EXISTING HOUSE
1/2"CDX PLYWOOD OR -1/16,"
OSB NAILED 3" OC ON ALL
PLATES AND 6" OC ON STUDS
TYVEK HOUSE WRAP
GALV PAPER
BACK WIRE LATH
1/8" STUCCO
ONE LAYER 030 FELT
O
4" 3000 PSI CONCRETE SLAB WITH F15ERMESH
OVER CLEAN COMPACT TERMITE TREATED SOIL.
COVER WITH 6 MILL VISQUEEN
11 OII / 11
1� 1/2"X6" REDHEAD EXPANSION
BOLTS MAXIMUM 24" OC WITH
BOTTOM OF FOOTING 2" SQUARE WASHERS
MINIMUM 12" BELOW GRADE
EXISTING SLAB AN
CUT SECTION DETAIL
NOT TO SCALE
SLAB AND FOOTINGS
L (2) 3/4"X6" HOLE IN EXISTING HOUSE
IN1GS AND EPDXY THE (2) 5/8" REBAR
1 NEW FOOTINGS
EXISTING TO NEW FOOTING DETAIL
NOT TO SCALE
ATTACH WINDOW TO STUDS THROUGH WINDOW
FIN PER YOUR WINDOW MANUFACTURE INSTRUCTIONS
TO MEET WIND LOAD AND COMPRESSION RATINGS
FOR YOUR JOB LOCATION
CAULK WINDOW PER YOUR
WINDOW MANUFACTURES SPECIFIC
RECOMMENDATIONS TO MEET WIND
LOAD AND COMPRESSION RATINGS
FOR YOUR JOB LOCATION
1�
EXTERIOR STUD WALL
WOOD WINDOW ATTACHMENT DETAIL
NOT TO SCALE
I HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED
DESIGNS AND FOUND IT TO BE IN COMPLIANCE WITH CHAPTER
16, SECTION 1609 OF THE FLORIDA BUILDING CODE FOR 120 MPH
(3 SECOND GUST) WIND ZONE - 100 MPH FASTEST SPEED AND THE
ENTIRE 2001 FLORIDA BUILDING CODE, RESIDENTIAL AND ALL
2009 BUPPL ENTALS y ]
DOI
L, HANSON P.E. LICENSE NO, 38684
P.O. BOX 1128, DADE CITY, FL 33526
I�by
Z
v 50 -4
g t6
Z�MMQ
ymQ W
try
14
3Jt�NQ
Z
W
f-
0
O X
21
z zw st;
a
N Z z 9
ZA
U
U1
3: U zz
o
Z
Z
}— Q Z
� VW
-
n
N
F-
0
O
N_}
�
W
QL
lu �
O
z
O
u-
(V!
V
O +-
w
(�
TOTAL AREA
140 SQ, FT.
PG
2Of: 2
- NAN YA PLASTICS CORP.
PLASTPRO INC.
9 PEACH TREE HILL ROAD
L IVINl3STON, NEW,IERSFY 07039
DISTINCTION SERIES
GLAZED FIBERGLASS DOOR
INSWING / OUTSWING
rrNOWIMPACTrr
GENERAL NOTES
I . This product has been evaluated ono is in compliance wlrn the 2007 Florida Building Code
(FBC) structural requmvincnts excludiny the "High Vebcily rtuiik une Tone' (HVHZ).
2 Product anchors sholl be as listed and spaced as shown _-1, details. Anchor embedment to
base material shall be beyond wall dressing or stucco.
3. When used in areas requiring wino borne debris protecfic this procucl is required to be
protected with an Irrpoct resistant covering that complle, with Section 1609.1.2 of the 2007
FBC,
.4. For 2x stud homing construction, anchoring of these units mall be -he some as that shown
for 2x buck masonry , orittruction
5. Site Condit ons that deviate prom the details of this drawing; reoutre further engineering
analysis by a Ilcensea engineer or registered architect.
TABLE OF CONTENT,
SHEET#
DESCRIPTION
I
Ty icol ele,oticn, design pressures, 6 general acres
2
Door panel aetolis
3
Horizontd cross sacfions
-Terdes
4
cross sections
5
Buck and frame onct__ng • 2X buck masonry cc struction
6
Rome onchnrin - I buck masonry consivocticr
7
Bil or motenot., g oz ng detail 8 components
I
LD
7 0
c
x
0
37.50' MAX. OVERAII
FRAMF WIDTH
O
0
INSWING
INSWING
37:50" x 82.00"
21.00" x 63.00'
GI
+50.0 -50.0
OUTSWING
37.50" x 80.W'
21.00" x 63.W'
+60.0 -60.0
Irwa. en: AL
c1n r. A
Y
U u
IL
TYD. HEAD a TYF. HEAD � p 1:
d AI•AB JAMBS i
MASONRY J' SEE NOTE i MASONRY
OPENING SEE NG
z
i � $
�{ FRAME -� z
o Rix
2X BUCK
U
2X BUCK
(� o
in
v a.
BUCK ANCHORING STRIKE JAMB FRAME ANCHORING HINGE JAMB z
Masonry 2X buck construction in
NOTES: 28
J
1. I/4" Elco concrete screws anchoring 2x buck require a r,aini,nnum I" clearance to masonry edges, 0 1-1/4"minM imum �� �
TJ
embedment and a minimum 4' clearance to adjacent :oncrete screws. Substitution of equal concrete screws from a ,
iD
different supplier may have different edge distance anc center distance requirements. Concrete screw locations of tho
corners may be adjusted to maintain the minimum edgre distance to mortar Joints. If concrete screw locations noted as ��' o
"MAX. ON CENTER" must be adjusted to maintain the mirdmum edge distance to mortar Joints, oddltlonal concrete M DAM D 2 08 i
screws may, be requires to ensure the maximum on ceroar dimension is not exceeded. Iukx: N.T.S. 9
27 win BY. AL n
anc. an LFS ss
a
LATCH B DEADBOLT DETAIL HINGE DETAIL
e w
I
i
i
Wood TODDnD Srr.a oGtPner I f1 (e Q
Tablas 700o a teW
ead..2aoD
k:anmmry
Gmmodi4.
W 1dIA t h I b GnYHlaa 14 M..d a II9 ly.w.01
78 is 4 laehna"� D'•'I WIdp1 191 / GnuMIM oe Ileac a Ili. piano 25 L2 4 2 18 1/p 4 MM.Ilaron Ow .
29 to 1 no 2 2S 112 q no 2
4 no 29112 4 no,__ 2
521;8 4 i 47 4 vM 1
Y°a 1 621re 4 w 1
Ilaleht E{ Lt Ya4 1
25 L3 Eb InwaBaden owe.
t v7 Na a ve 21 ve 37re Height L7 L2 L3 Eb Inwn.don ttvre.
37 3/8 U2 Na 17i/e 7J in 3716 7 25 2 Na 141/2 20 to
49 5/e tin Na 2 37 3/e 2 4 to 2
26 3/8 45 j•1 3 7l8 2 Na 23 1n 73 4 1/2 2
55 1k v2 Na % td 51 No 3 7M 49 5/e 2 Ne 25 t/7 45
e2 ttn 73re 7 55 9N z N, 11n 2
7t'.db Q8 hre 97re 1 -' 291/7 67 q tp 71rz 18378 11 yB 871re 37/8 82 2 7
32 t8 v2 571/7 11n 1
tf3 t trz 28 we 53 5/8 78 i/e 1 7i 7 20 11 in 88 i12 a 1n
3 7/e 1 B3 1
2 78 in 41rz
1
Moduilr 53 U2
Modular
Wlath Eh1�Es Gltbrline of H..d a IIII n0
23,12 q l"MIlanon Dw Width Eh Ea GnYr1111ao.Headatill. w
no
27n q 2 z31n . .,lsiwnanon t,w
3t q 2 271n 4 no 2
351 n 4 7 31412 , 2
391/2 q 2 3510
4
47112 q Y. 1 43Y.7n __. -._ _- _..Yee. _-
1
4
an 1
Ha7pA1 Et Lt 47112
L2 13 Eb enwilatimowe,
27 12 1 1/2 Na 15 J18 23 Sre J 7re e Et L t L2 L9
351n 11n 2 271n � 2 Eb Irletallatlan t7w
to
Na /9 are 31 Ste 3 7re Na I5 112 2]
z 1 to 351n 11n
Na 23 3/e 30 Ste 3 7le 2 2 Na 0112 91 1 in 2
47 7r2 1 1n Na 25 3/8 4J Sre 3 718 47 f/2 2 Na 23 in 39
st 1n 2 471n 41n 2
1 1/2 Na 27 3/e 47 y8 3 718 2 row 25 v2 4.3 q 2
89 /n 1 il7 Na 31 3/e SS S/A 3 7J8 2 81 V. 2 Na 1112 Il
1 trz z
71 to 2 � V. I,rz
193�8 135r8 81 y8 37/e 1 2 Na 311rz e8 Ili 2
&J nrz 1112 31 Ye 55 W 79 de 3 7/8 714 2 Z9 13 to 61
1 e31/2 2 2e 41n h
s51n 1 >a ofa 1rz t
Fastener I ncation Table Motes Q
1) All dimensions shown taken from the buck width or height of the window frame.
2) Based on the Milestone Series No. and size of the window to be installed, enter the correct table above
to determine the locations of the No. 8 Wood or Topping
2 illustrations of right. The applicable installation illustration snisenot d snd thon e t bler Installation No. 1 or No.
3) Install the No. 8 Wood or Topping Screws of the locations shown in the table. Tolerance is +
4) An installation fastener is only required at the centerline of the head and sill when indicated in the
table as "yes". if "no" an installation fasterner is not required at the centerline of the head and sill.
5) This table is NOT oppiicoble to the nailing option. See Notes 0, P. 0, and R for nail installation
locations and spacing,
DESIGN PRESSURE RATING &
FBC CODE COMPLIANCE
(S) If exact window size is not
B
BuckFrame
zLlisted In fastener location
table, use fastener locations
Centerline Width
of Hand Width
listed for next larger size.
Eh
(T) Installations depleted In these
Instructions acceptable for
Qdesign pressures to 70 PSF
for the window sizes shown
In the table. Design
Pressures (D.P.) are positive
and negative. Overall
window assembly design
Buck L
rrane
Pressure may be less then
PSF
Height
and shall obe
de
determined In accordance
r
with Note 13 of FLEX20100.
L
(U) Production Glazing may differ
from that tested as allowed
Es _
by ANSI/AAMA/NWWDA Centerline
t
L 2
L3
Eb I
10 101A.S. 2, 101A.S. 2/NAFS Of Sill INSTAL I IIDN Na 1 Q
or AAMA/WDMA/CSA
101/I.S. 2/A440 andyindoSl2. y�l�blllt
>36' to 52-1/8, Wide at Head Q SIII
applicable Building Code.
See Note 12 and 13 on >59-1/2• to 83-1/2' High at Jnnbs
Drawing FLEX 20100 for
further details.
Buck 6
M Structural two by wood buck
Frame
and/or framing at the head,
Width
sill and Jambs to be securely
Eh
fastened to transfer the load
to the wood structural
substrate per the FBC and
the engineer of record-6
details as applicable.
M See FLEX20100, Notes 10 to
15 for additional FBC Code
Buck L
Compliance.
Frame
Height
Et
i�
L2
I M,-; -3
L3 I_-
t3e8ei inns/oe
seals: Nn
Eb
Drawn ter; M
Chocked sY: 3H
1dSI9LLT1_ pN tdD� Q
1dJrlotaW SI>!e Aooll nnir
to 36" Wide at Heatll.L Sill
to 59-1/2, High at Jambs
Drawing No. FLD(21120
�y
N53
1
2�y�o
Z�MMQ
y64QQ W
w
Q y cN * 2
�SJVNQ
H
?�IDNZ W
O
�a�aQLL
39 7� i/%�°
I