HomeMy WebLinkAbout4826 Airport RdEly a 2 0 U N WALL SCHEDULE STEEL PERLIN WALL WITH STEEL EXTERIOR SIDING 2X4 WOOD STUD WALL EXISTING BUILDING DATA: SQUARE FOOTAGE TABULATION OFFICE SPACE 103 STORAGE 815 RESTROOMS 6e WAREHOUSE 5132 COVERED ENTRY 155 COVERED TRUCK PARKING 1015 TOTAL 8609 OCCUPANCY: MIXED BUSINESS GROUP B STORAGE GROUP 6-2 CONSTRUCTION TYPE. V NON SPRINKLED OCCUPANCY LOAD WAREHOUSE 5132/500 • 12 PEOPLE OFFICE AND RESTROOM 111/100 • 8 PEOPLE STORAGE 815/300 • 3 PEOPLE ENTRY AND COVERED PARKING N/A TOTAL OCCUPANCY LOAD . 23 PEOPLE C d9' In" 2.411 AS BUILT FLOOR PLAN 311ro" = V O" Please be advised this review of plans submitted is a gory review to assist the contractor in compliance with epplicablo fire safety codes. This review is not intended io be a final approval of the submitted plans. It is the cOnVWtor's sole mWnsibility to ensure that the plans are in oon>piete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non-compliance, it shall be the contractor's sole tlesponsibility, at their sole expense to brkV those areas in compliance. The City assumes no Fesponsb ity for the contractor's failure to be in compliance wOh all applicable NFPA Codes and local ordinwoes, OUBMITTEt,1 LAN(S) AVE EEN RRViEWED BY ZEPHYRHILLS'T AL'S ICE Date: -wiewer: SIC- XR4 ` , r EWDAr k,/ CITY OF ZEPHYRHILLS � -PLANS S ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L)Ds`r' P.r FLOreIDA LICFNESE N1 o- . ER 31'1`36 I HERBY CERTIFY THAT I WESE PLANS ANC SPECIFICATIO NS WERE PREPARED e�,r ME p. UNDER MY G1REvT SUPERVISION ARE IN COMPLIANCE WITH-H4APTER !:o, SECTION 1609 O F THE FLORIDA BUILDING, CODE' 2001 FOR IPO MPH (3 SECOND GUST) WIND ZONE - 100 MPH i^ASTEOT Ot EED .AND THE ENTIRE 2001 FLORIDA BUILDING CODE AND 200E SUPPLEMENTS y 2 C� r\ L � q CA w � NQ (VIV ao WcoC� A: io 00� y zt v all Q Vj �w !1w �JvN 4i 2oNpQML4 �H C L W O r c+1 tlJ �'p U N U '-' u CM zL Ogg U u3 Ul Q o tW u J W L p� Ld SUN 0 ui d Q z O N Q1 tY Ilk- (3 4 O z O 3 ju z Q Q O O � O LL Lu O LUt LU O E 9 � D 1 G 1 OF (0 rael KAY $ I388 f ■m�rerl �^,1,a^rr�-t'I!'�IfI F■�I"iIP'�11>I�fl�illlllll■IFf1ROI1tItIA�IIIGl1■N�IIIIII�I■1�11TIo'�19f7f1�IIII1oIr�l'fI�T4�PTTI�fI"nlf'�I�I"°I�""�'�I'9IT�111�'�F , N!■�1�■ o, o. ELEVATION 32' 4° 8Z - wQ - �A ;o _ ZZ O O O ® O 9' 10" F, z a - - - - �_0� -. BLOCK FILL OPENING AND INSTALL METAL l7 a 3 �7 - - - - DOOR AND FRAME IN OPENING, NO CHANGE - NEW Y F - _ - - TO EXISTING LINTEL AT OPENING _ - o 25 ml- NEW OFFICE aD m SETTLEMENT AREA DRYWALL CLG '10 r DRYWALL CLG t0 - X Op X - O FI O O FAX MACHINE o _ EXISTING TRUCK PARKING AREA 0 `9 0ELEVATION CUT OPENING IN EXISTING BLOCK WALL _ FLOOR - - AND INSTALL NEW FIXED GLASS WINDOW. NEW - - - - - INSTALL LINTEL ABOVE OPENING - - X - N O OFFICE DRYWALL CLG _8 LL NEW x x OFFICE DRYWALL CLG 41 I6 5" 4' 0" _ 9' loll Y a 41s" X 4s2" NEW o STORAGES N 3'0"X&'q1j DRYWALL CLG X p a� III I I I I Iiw FFnTT7i,i I I 114i dz� o-Q QN - - - - X o EXISTING " DRY STORAGE - EXISTING (5)RISERS . 6" TO LOADING DOCK - - - EXISTING WAREHOUSE o, o" FLOOR ELEVATION - WALL SCHEDULE 8" BLOCK WALL T. STEEL PERLIN WALL WITH STEEL EXTERIOR SIDING, 2X4 WOOD STUD WALL REVISED BUILDING DATA: SQUARE FOOTAGE TABULATION OCCUPANCY: MIXED BUSINESS GROUP 15 OFFICE SPACE l86 STORAGE GROUP 6-2 STORAGE 69 RESTROOMS 135 CONSTRUCTION TYPE: V WAREHOUSE 6389 NON SPRINKLED COVERED TRUCK PARKING 1015 OCCUPANCY LOAD WAREHOUSE 6389/500 • 13 PEOPLE TOTAL 5545 OFFICE AND RESTROOM 921/100 ■ 10 PEOPLE STORAGE 69/300 - I PEOPLE ENTRY AND COVERED PARKING N/A TOTAL OCCUPANCY LOAD - 24 PEOPLE NEW "19' 10" EXISTING RAISED LOADING DOCK FLOOR ELEVATION OIL DEMO NOTES: (A) CUT FRONT !WEST) BLOCK WALL DOWN TO BE FLUSH WITH LOADING DOCK FINISH FLOOR. (Es) REMOVE EXISTING STAIRS AND CONCRETE FILL AREA WHEN POURING NEW LOADING DOCK AREA I I I 3.J I i _ I FA I I I B'O"X8'O" O.H. DOOR ' 8'O"XS'O' O.W. DOOR - „ 8`o"X8'0" O.H. DOOR r�--- 4' 0" 8' O 4' 0" 8l O" 4-0". 8' O 31 Q ADD ON CANTILEVER ROOF AREA EXISTING BLOCK WALL LINE TWAT WAS REMOVED. GRIND FLOOR IF NEEDED IN THIS AREA 4' 0" CONNECT NEW FIXTURES INTO EXISTING SANITARY LINES. CUT SLAB AS NEEDED. 3030 s030y AREAS AND ��Oc6$, TERMITE TREAT DISTURBED COVER WITH 6 MILL VISQUEEN AND PATCH WITH 3000 PSI CONCRETE co \ ' NEW o ' I NEW o ' RSSTROOM\MT i R I -/ FORMED AND POURED 12" CONCRETE I / in YWALL D CLG \ / DRYWALL CLG f STEPS WITH (5) RISERS s 6" TO LOADING I r % DOCK. LOCATION OF STAIRS MAY VARY ~ I %6� N4142" ' 4112" NEW RAISED LOADING DOCK - - - FORMED AND POURED 12" CONCRETE STEPS WITH (5) 2 6 FLOOR ELEVATION RISERS + T TO LANDING. _ - CUT OPENING IN EXISTING 15LOOK WALL AND INSTALL METAL DOOR AND FRAME INSTALL LINTEL ABOVE OPENING W LL X� 00 8'011X8'0" O.H. DOOR , - - S'O1'X8'0" O.H. DOOR 6'O"X5'O" O.H. DOOR , 8b"X8'O" O.H. DOOR - - - - - _ - - 8'O"XB'O" O.N. DOOR - 8 0" 4' 0" a' O" 4' 0" 8' O" 4' O" D" 4' 0" e' 0" 4' 0" 4, 0" ADD ON CANTILEVER ROOF AREA ADD ON CANTILEVER ROOF AREA 100,011 REVISED FLOOR FLAN 3I1(011 1' oil ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS s FLORIDA ucc-NsE NUMBER 31296 HERBY CERTIF THAT THESE PLANS AMC) SPECIFICATIO NS WERE PRE'AR-e.V '3Y ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE XITH C<444,PTER ib, SECTION 1609 O F THE FLORIDA BU11..DING t30?DE 2001 FOR 120 MPH (3 SECOND GUST) WIND ZONE 100 MPH FASTEST SPEED AND THE ENTIRE 2001 FLORIDA BUILDING CODE AND 2009 SUPPLEMENTS y 2 C� t W w N Q to i CR � M y TR Q W op Caass�W�� W 0 �^�1�1w� 3 .VN�M .4J? � 4i QMQM O W O r r cow# z LL caJ L IL U z v� u' ztu 0 a 4D L Ld n{ O Q d) N O CD O Z O z d ID V u i� ED O Lu O if- LL PG 2OFro ARKAY * 13 - LOADING DOCK FINISH FLOOR MAIN BUILDING FINISH FLOOR GENERAL NOTES: THIS RENOVATIONS HAS BEEN DESIGNED TO CONFORM TO THE 2001 FLORIDA BUILDING CODE AND 2009 SUPPLEMENTS ARKAY ENGINEERING INC, A REGISTERED LICENSED, MO RIDA PROFESSIONAL STRUCTURAL ENGINEERING COMPANY: HAS APPLIED " RATIONAL ANALY 818" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADD INGS SHALL BE DESIGNED FOR THE FOLLOWING SUPERIMPOSED LOADS FLOORS, LIVE LOADS - 40 P.S.F. DEAD LOADS - 10 P.S.F. BLAB, LIVE LOADS - 50 P.B.F. DEAD LOADS - 10 P.S.F. WIND DESIGN ASSUMPTIONS. COMPLIES WITH SECTION 160E FBC BUILDING EXPOSURE - B BUILDING IMPORTANCE FACTOR - LO MEAN ROOF HEIGHT 30' OR LESS HEIGHT 4 EXPOSURE ADJUSTMENTS COEFFICIE NT - LO ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT • + / - 0 .18 SEE WIND SPEED AT BOTTOM RIGHT OF ALL SH EETS SOIL BEARING 4 COMPACTION: THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE 6 OIL BEARING CAPACITY OF 2000 P.B.F.( MINIMUM ) THE CONTRACTOR/PROPERTY OW NER IS RESPONSIBLE FOR VERIFYING THAT THE SOIL ON THE SITE 18 PROPERLY PREPARED AN D COMPACTED SUCH THAT IT CAN SUPPORT A 2000 P.S,F. FOUNDATION LOADING ARKAY ENGINEERING INC, A. REGISTERED LICENSED FLOR IDA PROFESSIONAL STRUCTURAL ENGINEERING COMPANY, DESIGNED THESE FOUNDATION$ W ITHOUT VISITING THE CONSTRUCTION SITE NOR PERFORMING ANY SOIL TESTING ARKAY ENGINEERING INC SHALL NOT BE RESPONSIBLE FO R THE SITE SOIL ABILITY TO SUPPORT THE BUILDING LOADS FOUNDATION 4 SLAB - ON- GRADE NOTES : BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGA NIC MATERIALS,. ANY ADDITIONAL FILL PLACED ON THE BUILDING PAC) AR EA, SHALL BE COMPACTED SUCH THAT IT CAN ADEQUATELY SUPPORT A 2000 P.:$.F, FOUNDATION LOADING. BLAB $$H�ApLL�BREM TPLLAC�E�gOVER p Agp6��MIL VAPOR BARRIER ON CLEA N ADEQUATELY COMPACTED CONCRETE UTILPIZED IN THE FOUNDATION AND SLABS "A LL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 P.S.I. REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND I DENTIFIED IN ACCORDANCE WITH ASTM A -615, LAP SPLICES, WHERE REQUIRED SHA LL BE A MINIMUM OF 25" FOR o5 REBAR, 30" FOR o6 REBAR 4 35" FOR 01 REBAR PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGH T OF 4 COURSES ( AFTER FINALSITE GRADING) THE CONTRACTOR BUILDING OW SHALL DETERMINE THE RAC OR OR NER EXACT STEMWALL HEIGHT BABE UPON 817E CONDITIONS P RIOR TO POURING THE FOUNDATION AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 CO URGE ARE REQUIRED A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRECTED FROM MARKER TO MARKER TO VERIFY R EQUIRED SET BACKS MASONRY WALLS: CONCRETE MASONRY UNIT SHALL BE HOLLOW UNIT MASONR Y IN ACCORDANCE WITH ASTM C-90 AND SHALL HAVE MINIMUM F'M OF 1500 PAJ. MORTAR SHALL CONFORM TO ABTMC -210 AND SHALL BE E ITHER TYPE M OR 8 REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND I DENTIFIED IN ACCORDANCE WITH A6TMA-615. LAP SPLICES WHERE REQUIRED $4AL1 BE A MINIMUM OF 25" FOR 05 REBAR 30" FOR 06 REBAR AND 35" FOR 01 REBAR. GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE OF 3/8" PLACED AT 8 TO 11 INCH SLUMP AND HAVE A M INIMUM 28 DAY COMPRESSIVE STRENGTH of 2000 P.S.I. ( WHEN TESTED PER ASTM C-1019 ) PROVIDE CLEAN OUT OPENINGS ( 12 So. IN, ) IN CELL S CONTAINING SPLICED REINFORCEMENT, WHEN THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT TIMBER MATERIALS: LUMBER UTILIZED IN BOTTOM PLATE, TOP PLATER ,POST , STUDS PACKS AND BEAMS SHALL BE 02 YELLOW PINE (OR BETTER) INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T, PINE BOTTOM PLATE AND SINGLE 2 X 4 02 SPRUCE TOP PLATE WITH STUDS SPACED MAXIMUM 24" OC. WALLS TO HAVE 1/2" GYPSUM BOARD E ACH SIDE, ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH INS MUST BE COMPLETE, INSPECTED AND APPROVED PRIOR TO REQUESTING THE FRAMING INSPECTION, SOIL TERMITE TREATMENT: TERMITE PROTECTION SHALL BE PROVIDED BY REG16TERE D TERMITICIDES, INCLUDING PESTICIDES APPLIED TO SOIL, OR WOOD, BATING SYSTEMS, OR OTHE R APPROVED PROTECTION LABELED FOR USE AS PREVENTATIVE TREATMENT TO NEW CONSTRUCTION, A CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO T HE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A " CERTIFICATE OF OC CUPANCY WILL BE ISSUED. THE CERTIFICATE SHALL STATE, (PER FBC) THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FO R THE PREVENTION OF SUBTERRANEAN TERMITES, THE TREATMENT 18 INACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMERS SERVICES INITIAL SOIL POISONING TREATMENT SHALL BE DONE AF TER ALL EXCAVATION BACKFILLING 4 COMPACTION ARE COMPLETE (PER FBC) ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SH ALL BE RE- TREATED INCLUDING ANY BOX OR FORMED AREAS ( PER FBC) BOXED AREA IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF AN ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANC E OF THE SOIL AFTER THE INITIAL TREATMENT ( PER FBC) A MINIMUM 6 MILL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE TREATMENT SHALL BE REQUIRED (PER FBC) ANY CONCRETE OVERPOUR , MORTAR OR STUCCO MATERIAL 8 ALONG THE FOUNDATION PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT, ( PER FBC) EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 12" OF THE STRUCTURE SIDE WALLS (PER FBC) AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE IN STALLED AFTER CONSTRUCTION IS COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER 18 APPLIED, SHALL BE RETREATED (PER FBC) CONDENSATE AND ROOF DOWN SPOUTS DISCHARGE AT LEAS T 12" AWAY FROM THE BUILDING SIDE WALLS (PER FBC) AFTER ALL WORK IS COMPLETE ANY LOOSE WOOD AND FIL L MUST BE REMOVED FROM BELOW AND WITH IN 12" OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES TUB TRAP BOXES, FORMS, SHORING AND ANY OTHER CELLULOS E CONTAINING MATERIALS PER (FBC) THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EX CEPTIONSf PAINT AND DECORATIVE CEMENTITIOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6" T O ALLOW FOR INSPECTION FOR FUTURE TERMITE INFESTATIONS (PER FBC) EXTERIOR WINDOWS 4 DOORS: ALL EXTERIOR WINDOWS 4 GLASS DOORS OR ENTRANCE DO OR SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWOA 101/162 STANDARD AND BEAR AN AMMA OR WOMA LABEL IDENTIFYING THE MANUFACTURE PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES $HALL BE TEST OR ENGINEERED TO TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING S UBBTRATE INSTALL ALL WINDOWS AND DOOR ASSEMBLIES PER THE M ANUFACTURE ANCHORING RECOMMENDATIONS TO ACHIEVE THE DESIGN PRESSURES SPECIFIED ELECTRICAL, PLUMBING, 4 MECHANICAL: IN ACCORDANCE WITH CHAPTER 411.003 (2) (I) OF THE FLORIDA ADMINISTRATIVE CODE, ELECTRICAL PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMB ING AND MECHANICAL SYSTEMS DRAWN HERON ARE BASE UPON A DESIGN PROVIDED BY THE OWNER TO A DORESS HIS/HER REQUIREMENTS. ALL ELECTRICAL OUTLETS IN BATHROOMS, WITHIN 6' FE ET OF SINKS EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND F AULT INTERRUPTER "CFI" CIRCUIT GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N. E,C, SAFETY GLAZING, THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARD OUS LOCATION FOR THE PURPOSE OF GLAZING (U GLAZING IN SWING DOORS, FIXED AND SLIDING PAN EL OF SLIDING DOORS ASSEMBLIES (2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND 8 4OWERS, GLAZING IN ANY P ORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE DRAIN INLET (3) GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" RAO IU8 OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 6 0" ABOVE THE FINISH FLOOR OR WALKING SURFACE (4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PA NFL OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT M EETS ALL OF THE FOLLOWING (A) EXPOSED AREA OF AN INDIVIDUAL PANE GREAT ER THAN 9 $Q. FT, (B) BOTTOM EDGE LESS THAN 1S" ABOVE THE FLOOR (C) TOP EDGE GREATER THAN 36" ABOVE THE FLOOR (D) ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY OF THE PLANE OF THE GLAZING NEW WEST ELEVATION 3/16" = 11 O" BLOCK WALL BEYOND OF OFFICE AREA WITH OPENING CHANGES ( ( I I � I I II I I I I I it I I I I ( 12 1 VER- 6.0. - TOP OF BLOCK WALL o LOADING DOCK LOAOING DOCK FINISH FLOOR fLDING NEW NORTH ELEVATION 3/16" = V O" 12 _ VERIFY� 1 .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... ... .. ... ... .. 0.. .. . .. . .. .. .. OA ING K FINISH F O L .. .. .. . D DOG LO R - ... .... ... .. ... .. ... .. ... .. ... I'.'..'.'..'.'..�... MAIN BUILDING. FINISH FLOOR I. NEW SOUTH ELEVATION 3/1611 = 11 0 11 ARKAY ENGINEERING INC, STRUCTURAL ENGINEERS a r� C, RIC1 ARD t . GIDDEY PIE, FLORIDA OCENIAE NUMBI="R 31296 I HERBY CERTIFY THAT THESE PLANA- AND SPECIFICATIO NS WERE PREPARE BY t-tv OR UNDER m)- DIRECT SUPERVISION ARE IN COMPLIANCE WITH rMAP?! R 16, SECTION I&OS O F THE FLORIDA BUILDING COl : 20 1 FOR 120 MPH (3 SECOND GUST) UJIND ZONE - 100 MPH FASTEST SPEED AND THE ENTIRE 2001 FLORIDA BUILDING CODE AND 2009 SUPPLEMENTS y Z G � W Zyt NQ 04 O 00 � c- Qy�wN �f Z ,�M � , �.,vN� 4i O`yWN 4 t4 It 0 7111 r �r COIL! m coo tu- ci LU V u 0toCal U- ion0 0 0 CA O � tYi r � O , .z ju Q Q VJ Q � C j Fu N lu B 0 Q O l O LL 3 OF ARRAY 0 1382-� 54" MIN TOILET 18" MIN 18" MIN 24" MIN LD HOLDER NOL.DER 1 42" MIN 77 LAY if M 71cp M CLEAR FLOOR SPACE HANDICAP TOILET DETAIL --------------- 60" MIN GRAS BARS A GRAB BAR SHALL BE PROVIDE. LOCATED 33" INCHES FROM AND PARALLEL TO THE FINISHED FLOOR, MEASURED VERTICALLY TO THE TOP OF THE RAIL WITH VARIATION OF NOT MORE THAN 1/2 INCH AND: I. SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/2 INCHES 2. SHALL PROVIDE 1 1/2 INCHES OF CLEARANCE BETWEEN THE RAIL AND THE WALL 3, SHALL BE SO DESIGNED AND SUPPORTED AS TO WITHSTAND A LOAD OF NOT LEW THAN 250 LBS APPLIED AT ANY POINT. DOWNWARD OR HORIZONTALLY. 4. SHALL BE CONTINUOUSLY GRASPABLE ALONG THE ENTI RE LENGTH. SPECIAL NOTES GRAB BAR MEETING THE APPLICABLE ANSI STANDARDS ARE DEEMED TO BE IN COMPLIANCE WITH THE INTENT OF THE LAW WI4ETHER CENTER SUPPORTS EXIST OR NOT. S. SHALL BE AT LEAST 42 INCHES LONG AND SHALL BE CENTERED AT THE LEADING EDGE OF THE WATER CLOSET. ------------------ 6" MAX. ------- TOE CLEARANCE r1l, ------ z 4 i I I I III' MAX LAV DEPTH 8" MIN KNEE CLEARANCE HANDICAP SINK DETAIL SINK I. SINK SHALL BE MOUNTED WITH THE COUNTER OR RIM NO HIGHER THAN 34N FROM THE FINISH FLOOR. EACH SINK SHALL BE MIN@MUM OF Fs 1/2" DEEP, 2, CLEAR FLOOR SPACE RESTROOMS SHALL HAVE AN UNOBSTRUCTED SPACE OF AT LEAST 60" IN DIAMETER OR 52" BY v FINISH INSIDE DIMENSIONS ADJACENT TO THE LAVATORY AREA. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19" UNDERNEATH THE LAVATORY OR SINK RIOR STAIR DETAIL k loo' o" FOUNDATION FLAN 3/1t0 011 ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS fts- . . —HAS* D L. KIDDEY" P.E. FLORIDA ur-Ewwz: NUM£5>:2 3ivuo I HERBY CERTIFY T14AT THESr- ',=LANE+ AND SPECIFICATIO NO WERE PREPAREI> EBY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 O F THE FLORIDA BUILDING, CODE 2001 FOR 120 MPH (3 SECOND GUST) WIND ZONE - 100 MPH FA6TEST SPEED AND THE ENTIRE 2001 FLORIDA BUILDING CODE AND 2009 SUPPLEMENTS by Z V ^ y W �yHHp 2 tic1,4 C9 �► eh V QO WooC�: p O -`, cOo cq O�y^ V yZ O H 3 y w 1 -4 w 2�p�eN2 C �Hpt� 0 r w``' M � Uu L Z L s o z Q) -- 0 c Q? ll z L L T 3 0 � LLI U� ,>7 s u (d)o`c W 0 z 0 m � O M Z W Z Q Q � l� V _z H Q�00 u- (L Lu O L 4OFro .BRICK WALL TIES ATTACHED TO SIDE - OF EXISTING BLOCK WALL AND LAYED INTO EACH COARSE OF NEW BLOCK '1 74 —_ 9 .IAe' �. m [ 1 PII, .[ f 1 � 4'u 1I`• � �! �(L � S.. Ptils 1 w" !Qf _ _ .00 EXISTING OPENING WIDTH yi OIl 31 4 Ili 11 411 J _ - (STING LINTEL ABOVE OPENING TO REMAIN UNCHANGED - LAY NEW BLOCK IN OPENING AND CUT FACE OF BLOCK AS SHOWN AND INSTALL VERTICAL 'S WA REBARDRILL INTO SLAB BELOW AND LINTEL ADOV AND EPDXY ROD. FORM AND FOUR SOLID FROM WITH CONCRETE, 1� SEE 1-19,10 NEW, 10,11110 Igloo MlNo ISO lamp ■ BLOCK FILL EXISTING OPENING FOR DOOR EXISTING BLOCK WALL DETAIL NOT TO SCALE INSTALL NEW PRECAST S" LINTEL ABOVE NEW OPENING AS SHOWN I CUT FACE OF BLOCK AT EACH END OF - OPENING AND INSTALL VERTICAL •5 REBAR. DRILL INTO SLAB AND EPDXY _ AT BOTTOM. FORM AND POUR SOLID FROM WITH CONCRETE I V/ 1 I- CUT AWAY BLOCK AS SHOWN I FINISH FLOOR TO S" ABOVE I HEIGHT I I 1 1 1 I 1 I I . i I I . I I I II ( 1 1 I 1 I Il 1 ( 1 I 1 1 1 1 1 1 1 1 1 r , 1 1 1 1 I 1 I 1 1 CUT NEW DOOR OPENING EXISTING BLOCK WALL DETAIL NOT TO SCALE EXISTING BAR JOIST ATTACHED 2X4 02 PINE TO THE BOTTOM OF EACH BAR JOIST WITH (2) 1/4"X2" SDS SCREWS 24" OC ATTACH 1/2" CEILING GYPSUM BOARD TO 2X4 02 PINE (TYP) 2X4 02 SPRUCE TOP PLATE ATTACHED TO 2X4 02 PINE WITH (2) I&D NAILS BRICK WALL TIES ATTACHED TO SIDE - - OF EXISTING BLOCK WALL AND LAYED INTO EACH COARSE OF NEW BLOCK Ao EXISTING OPENING WIDTH EXISTING LINTEL ABOVE OPENING TO REMAIN UNCHANGED mmmmmmm NN cLAY NEW BLOCK IN OPENING AND CUT FACE OF: RISEAR, DRILL INTO SLAB BELOW AND LINTEL WAN ABOVE AND EPDXY ROD, FORM AND POUR --VAS SOLID FROM WITH CONCRETE, VAE os NEW .1 NMI I OREN I 81110HEMENEM1101,111 In BLOCK FILL EXISTING OPENING FOR WINDOW EXISTING BLOCK WALL DETAIL NOT TO SCALE INSTALL NEW PRECAST S" LINTEL _ ABOVE NEW OPENING AS SHOWN CUT FACE OF BLOCK AT EACH END OF OPENING AND INSTALL VERTICAL -5 --- REBAR. DRILL INTO SLAB AND EPDXY AT BOTTOM, FORM AND POUR SOLID 1 FROM WITH CONCRETE. CUT AWAY BLOCK AS SHOWN FROM FINISH FLOOR TO S" ABOVE HEIGHT nr � 1 1 1 1 I I , I 1 I 1 1 CUT NEW WINDOW OPENING EXISTING BLOCK WALL DETAIL NOT TO SCALE 2X6 02PINE CEILING JOIST O 24" OC WITH R-15 INSULATION IN CEILING FF- ATTACHED 1/2"COX PLYWOOD TO TOP OF 2X64 02 PINE WITH 8D NAILS 4" Or - ATTACH 1/2" CEILING GYPSUM BOARD TO 2X6 "2 PINE CEILING JOIST (TYP) 2X4 02 SPRUCE TOP PLATE ATTACHED TO 2X6 02 PINE WITH (2) 16D NAILS 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD ON EACH SIDE OF STUD ON EACH SIDE OF STUD 2X4 •2 SPRUCE STUDS m W' OC WITH -II INSULATION REQUIRED IN 2X4 02 SPRUCE STUDS A 16" OC WALLS 2X4 P.T. BOTTOM PLATE ATTACHED TO CONCRETE FLOOR WITH (1) 08XI" 2X4 P.T. BOTTOM PLATE ATTACHED TAP CONS 24" OC TO CONCRETE FLOOR WITH (1)08XI" TAP CONS 24" OC RESTROOM WALL SECTION DETAIL TYPICAL WOOD STUD WALL DETAIL NOT TO SCALE NOT TO SCALE ELECTRICAL LEGEND STANDARD QUAD 100 VOLT TELEPHONE/DATA LINE WALL MOUNT 65 WATT SWITCH RECEPTACLE EXTERIOR LIGHT FIXTURE T"( EXIT 3 WAY DUPLEX 100 VOLT EXIT/EMERGENCY LIGHT EMERGENCY LIGHT SWITCH RECEPTACLE COMBO UNIT WITH BATTERY UNIT WITH BATTERY BACK UP BACK UP 2'X4' WRAPPED CEILING MOUNT 80 CFM BATH FAN 4 LAMP 40 WATT FLUORESCENT VENTED THRU WALL LIGHT FIXTURE OF BUILDING ELECTRICAL / LIFE SAFETY PLAN 311ro11 11 011 ARKAY ENGINEERING INC. STRUC RAL ENGINEERS RUCHARD L. K1'I;JDEY P,E, FLORIDA L'.CENSE NUMBER 312S6 1 HERBY CERT;t1=Y THAT THESE PLANS AND SPECIFICATIO NS WERE PREPARCD 131 ME O.P. Utn'DER MY DIRECT SUPERVISION ARE IN COMPL'.ANCE WITS! CF4APTER 16, SECTION I6OS O F THE FLORIDA BUILDING CODE 2001 FOR 120 MPH (3 SECOND GUST) WIND ZONE - 100 MPH FASTEST SPEED AND THE ENTIRE 2001 FLORIDA BUILDING CODE AND 200E SUPPLEMENTS y Z * MM Q `'� ` (I �o WO�� M y�-4o°v -42 HW W QMQ�''�4 ` W 0 M �in �pWs m�0 MCID�� Z 11 gaLJ Z JU !s Q n IlM) V 3 0� Il-dA. T yo Z a � nl O � 1 1 r N O O z Q Q O V/ ) O OzU-t f= LL v- jru 7"- V lu Q o lU O L FIG 50r-ro ARKAY 0 J3887 ! un me •!' re 11n!�.w��erne111 1a I ii IIMlillll PI�II�AIIIIIIIIIAIIII�I�'I I! hll7�lOnllll■M��RI�IA�V_Ak II I �gi�lil+l�llllfl� I�:I lift II lilfl �Ih � i�_�_1 if 11�1��1[;Iq'Ilrlli�lplll'I 61 oll ROOF PERLINS PER STEEL BUILDING MANUFACTURE -------------------- ---------------------------------------------------------- ---------------- --- 8" STEEL TRACK ATTACHED TO ROOF ADI� ON CANTILEVER ROOF AREA PERLIN WITH 1/4" X 1 1/2" SDS SCREWS TO BE ENGINEERED BY STEEL BUILDING 4" OC MANUFACTURE TO ATTACH TO EXISTING BUILDING COLUMNS 1 8" STRUCTURAL STEEL STUD WALL AT FRONT OF BUILDING. STUDS TO BE SPACED 16" OC 1 1 EXISTING STEEL BUILDING STRUCTURAL COLUMNS Q 25' O" 1 STEEL WALL PANELS INSTALLED , HORIZONTALLY TO FACE OF STEEL 25' O" STUD WALL 1 1 , 1 1 - - 1 8" STEEL TRACK ATTACHED TO CONCRETE WITH 1/2" X 8" ANCHOR BOLTS im 24" OC FORMED END WALL AND POURED WITH 3000 PSI CONCRETE, DECORATIVE STUCCO EXTERIOR OF WALL MINIMUM 1 1/2" STEEL PIPE RAILING PRIMED AND PAINTED LAY BLOCK FOR STAIRS AND ALLOW FOR 4" FORMED AND POURED CONCRETE CAP AREA AT LANDING LAY BLOCK FOR STAIRS AND ALLOW FOR 2" FORMED AND POURED CONCRETE CAP AREA AT STEPS _ 1' 411 i' cll it O --- LOADING DOCK FINISH FLOOR ---- ----- --- -- ------------ ------------------------ - - - - -- N ---MAIN BUILDING FINISH FLOOR 14 c4 05 VERTICAL REBAR AT LOCATIONS SHOWN ON FOUNDATION PLAN. POUR i „ , 11 tv ALL CELLS SOLID WHEN POURING O 8"Xi21" FOOTINGS WITH (1) 05 REBAR CAPS 11 11 EXTERIOR STAIR SECTION DETAIL NOT TO SCALE 12' 6" CLEAR SPAN (MAX) 6"X 25 1 BEAM WITH 6" FLANGE TYPICAL END VIEW OF "3.0 OF" WELDED AT TOP OF TUBE COLUMNS 20 GA COMPOSITE FLOOR DECK PANEL 1 1 11 O,1 1 "3,0 CF" COMPOSITE FLOOR DECK 11 O" or WITH 6" THICK CONCRETE POUR WITH 12 " BEND INTO SLAB (TYP) 6/6 10/10 WIRE MESH (3000 PSI) SUPERIMPOSED LIVE LOAD 133 PSF —.r----v----ti-----v-----v-----�r----v----ti-----v-----�r----r----v--- v---------v-----�r----v--------v----v----r----v----�---- -- — e e ° e o ° 12" X 42" X 42" CONCRETE PAD WITH (5) TACK WELD DECK TO TOP OF BEAM ae 05 REBAR EACH WAY AT EACH COLUMN e a e AT EACH EDGE AND IN CENTER LOCATION POURED ON TOP OF EXISTING o 4!0 0 SLAB .° o D D D D D D D D <t II II II EXISTING BUILDING FOOTING EDGE, II DRILL 6" HOLE INTO EDGE AND 11411 EPDXY VERTICAL "5 REBAR w 11 2411 OC MINIMUM 1 1/21' STEEL PIPE RAILING PRIMED AND PAINTED LAY BLOCK FOR, STAIRS AND ALLOW FOR 2" FORMED AND POURED CONCRETE CAP AREA AT STEPS OR FORM ENTIRE STEP AND POUR WITH 3000 PSI CONCRETE 11 4" nl - cll � LOADING DOCK FINISH FLOO cal MAIN BUILDING FINISH FLOOR INTERIOR STAIR SECTION DETAIL NOT TO SCALE 1/4 X 4 X 4 STEEL TUBE COLUMN WITH 3' 6" 70, 1/4" X 4" X 10" STEEL PLATE AT BOTTOM WITH (2) 5/0" X 6" ANCHOR BOLTS IN CONCRETE PAD, CUT 6ECTI ON DETAIL A NOT t0 SCALE FORMED END WALL AND POURED WITH 3000 PSI CONCRETE LOADING DOCK FINISH FLOOR 1 t O MAIN BUILDING FINISH FLOOR POUR FOOTING ON TOP OF EXISTING SLAB AS SHOWN AT INTERIOR LOCATION WITH (3) #5 REBAR ON CHAIRS WITH VERTICAL *5 REBAR 6 24" OC ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS t v RlCHARD L.. K DDT'!' = ,M FLORiOA LICENSE NUMBER 3-1296 I HERBY CERTIFY T,4AT TWTAE PLANS AND SP£CIFICATIO NS WERE PREPARED BY. ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CWAPTEP. 16, SECTION WOOS O F THE FLORIDA BUILDING CCDE 2oo-i FOR 120 MPH (3 SECOND GUST) WIND ZONE - 100 MPH FASTEST SPEED AND THE ENTIRE 2001 FLORIDA BUILDING CODE AND 2009 SUPPLEMENTS it, y Z W � -4 CA 2aMtq NQ ymQ� W o�p 40dW- W 0-4� v M M.4 p N t-4 W Ilk H y >r Wm 2� cct"Icq o � L— z L LoR 0 UJ pC D A W u---� Id p� (p QN� ui Q z 0 N Q�L 3 ccn � O � Z d w Z cA . Q Q- z u- 1 O v/ c^ _ VJ � V! 3: . O J O E3 PC-c (OOF(0 ARKAY 0 t3M-7