Loading...
HomeMy WebLinkAbout6548 Gall Blvdr W rM ngstreet 6548 GALL BLVD. ZEPHYRHILLS, FL 33542 This project involves the installation of the Win street Lite Decor package and the installation of back of house equipment line in the existing Pizza Hut. CITY CODES: 2004 IBC 2004 NEC 2004 I PC 2004 I MC 2000 I ECC PROJECT DESCRIPTION TITLE/SITE EX1.0 EXISTING & DEMO FLOOR PLAN A1.0 EQUIPMENT PLAN & SCHEDULES A2.0 EXTERIOR FINISH & SIGNAGE REQUIREMENTS M1.0 HVAC PLAN & SPECS. M2.0 FRYER HOOD & DUCT DETAILS M3.0 EXHAUST HOOD DETAILS P1.0 PLUMBING.PLAN P2.0 PLUMBING DETAILS E1.0 ELECTRICAL DETAILS & NOTES E2.0 ELECTRICAL FLOOR PLAN OWNER Pizza Hut, Inc. 14841 Dallas Parkway Dallas, TX 75254 Operating Brand: Pizza Hut/Wingstreet CONSTRUCTION YUM! BRANDS, INC. 1900 Colonel Sanders Lane Louisville, KY 40213 Contact: Alan Krueger Phone: 502.551.3070 MANAGER SHEET INDEX ARCHITECT ARCVISION, INC. 1950 Craig Rd, Suite 300 St. Louis, MO 63146 Contact: Justin Knepper Phone: 314.415.2400 PROJECT DIRECTORY Contractor Scope - Minimum Provide adequate electrical and/or gas service for WS equipment line, POS and TVs ✓ Relocate/remove equipment as per plan ✓ Install WingStreet equipment line ✓ Charge the ANSUL system ✓ Install soak tank for hood filter cleaning ✓ Remove existing blinds or curtains ✓ Remove "ceiling pizza" and all attachment hardware (typically Mainpath, R2K, R2K2 assets only) ✓ Paint dining room ceiling, beams, and frieze band ✓ Install three owner -furnished 32" TVs, mounts ✓ Install owner -furnished hi-def antenna ✓ Paint exterior walls and trim ❑ Remove existing manager/hours signs (patch damage) ✓ Add Pizza Hut/WingStreet door decals and hours decal at public entry ✓ Obtain permit approvals and final inspections Owner Scope - Minimum ✓ Install POS/RIS equipment at WingStreet finish station ✓ Install exterior WingStreet signage ✓ Remove existing art/artifacts (when wall painting is not required) ✓ Install logo panels, branded art/artifacts, localized art/artifacts ✓ Place table caddies on each dining table Place 2 W Tables, WS Barstools in central diningarea ✓ ac S ab es 6 0 VI Furnish New Hands -Free Hand Sink Contractor Scope - Conditional ✓ Install exhaust fan and related ductwork for vented hood over gas fryer/ ❑ Provide power for exterior signage ❑ Install owner furnished hands -free kit to nearest hand sink ✓ Install new owner furnished hands -free sink ❑ Replace all existing veggie light box panels with new branded panels ❑ Replace pendant fixtures obstructing view of TVs with owner furnished fixtures ✓ Replace existing carpet with owner furnished carpet ❑ Install blinds/roller shades in South and/or West windows ❑ Repaint roof ✓ Replace outdated "red roof" door handles with ADA compliant standard pull ✓ Stripe parking lot; repair as needed ✓ Remove existing artwork; patch/paint interior walls ✓ Paint interior wood trim Owner Scope - Conditional ❑ Remove/Relocate vending/games from entry and dining areas ❑ Repair/replace dining room furniture to meet Current Asset Standards ✓ Remove or replace all obsolete "red roof' graphics (i.e. cigarette urns, mats) ❑ Provide wait bench at entry (if one does not exist) PROJECT SCOPE OF WORK a � J O0 0 A, U. LL� 04.24.08 HAND SINK ADDITION 0 CONTRACT DATE: 03.21.08 BUILDING TYPE: ?????? STORE NUMBER: 95343 ARCV NUMBER: 080406 6548 GALL BLVD. ZEPHYRHILLS, FL 33542 EXISTING & DEMO FLOOR PLAN EXI 00 PLOT DATE: 02.19.08 v a s C PI E. ARTWORK SCHEDULE N.T.S. 04,24.08 HAND SINK ADDITION CONTRACT DATE: 03.21.08 BUILDING TYPE: ?????? STORE NUMBER: 95343 ARCV NUMBER: 080406 6548 GALL BLVD. ZEPHYRHILLS, FL 33542 Al 0 PLOT DATE: 02.19.08 8 ..... ... ............. . . ...... ............... .... ........ .................... al . . ......... . .. .... . ...... .. .. ............ . . ............. . ... ...... . . . ......... ... ....... ............. VA.df t On. ... ......... —or .......... .......... . ................ .......... Calm 11 il'All 1 REFER TO GENERAL NOTE H. 7"x7" (1,500 FPM VELOCITY) WELDED BLACK STEEL DUCTWORK FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. SEE DETAIL F ON SHEET M2.0. 2. EXHAUST HOODS SHALL BE INSTALLED & SUPPORTED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. FRYER EXHAUST HOOD IS LISTED UNDER UL FILE NUMBERMH18450. THE FILE DESCRIBES THE ALTERNATE CLEARANCE METHOD AND MATIMrSMUSED ON THE EXHAUST HOOD AS DETAILED IN NFPA 96. THE HOOD IS PROVIDED WITH 3" INSULATED REAR AIRSPACE. 4. CONTRACTOR SHALL FURNISH AND INSTALL 24 GA. MIN. STAINLESS STEEL BEHIND AND 18" OUTSIDE PERIMETER OF HOOD, ATTACHED TO WALL. 5. PROVIDE CLEAN OUT ACCESS DOORS AS INDICATED ON PLAN. CLEAN OUT ACCESS DOOR TO BE 4"x7" OPEN AREA ON THE VERTICAL SIDE OF DUCT. 6. REBALANCE EXISTING UNIT'S ECONOMIZER/OUTSIDE AIR DAMPER TO VOLUME INDICATED ON PLAN. HVAC NOTES D RIU P G U - ,IPE SLOPING DOWN LWAY FROM SHROUD IIN. 24 GA. G.I. PIPE NCLOSURE COVER - HEAD NAIL @ 6- O.C. !CREW THRU NEOPRI VASHER, 3 PER SIDE 2) 2x12 WD CURB OVER ;ECURED TO DECK ASE FLASHING MULTIPLE PIPE FLASHING 1 1/2" 11-0"1 E MIN. 24 GA. G.I. CAP FLASHING SECURE W/ SCREW THRU STEELlNEOPRENE WASHER AS NEEDED FOR PROPER SECUREMENT (4 SIDES)-� 2X6 @ 16-0.c;-�� z NOTE: SET SUPPORTS ON SOLID NON -RIBBED NEOPRENE, AND SECURE LAG BOLTS THROUGH STEEL/NEOPRENE WASHER 518"CDX PLYWOOD (2)2xl2, RIP FOR LEVEL PLATFORM BITUTHENE CAP SHEET OVER TOP OF SLEEPER EXTEND DOWN SIDES BY 2" BASE FLASHING FIBER CANT STRIP W/ 4" LEGS - NNL TO PLYWOOD 0,T 12- O.C. OOFING MATERIAL 20.- 20.- 2w 1 Od @ 6- O.C. CrypicAL) cR 2x6 BLOCKING 0 >; SLEEPER SUPPORT F A. ALL WORK AND MATERIALS SHALL COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AS APPROVED AND AMENDED BY THE GOVERNING CITY, INCLUDING APPLICABLE SECTIONS OF NFPA, UBC, OSHA, OR ANY INTERIM AMENDMENTS AT THE TIME OF THE PROPOSAL. PURCHASE ALL PERMITS ASSOCIATED WITH THE WORK. OBTAIN ALL INSPECTIONS REQUIRED BY CODE. B. CONTRACTORS AND SUB -CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. C. EXISTING CONDITIONS ARE BASED ON "AS -BUILT" DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. CONTRACTOR IS TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. D . ALL EQ U I P M ENT AN D AP P LIAN C ES S HALL BE I NSTALLED AS REQU I RED BY TH E TERMS OF THEIR APPROVAL, IN ACCORDANCE WITH THE CONDITIONS OF THE LISTING, THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND THE LOCAL CODE. MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE ON THE JOB SITE AT THE TIME OF INSPECTION. E. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO RECEIVE, OFF- LOAD, STORE, INSURE, CARRY UP, DISPOSE OF DEBRIS AND SET IN PLACE ALL OWNER FURNISHED ITEMS AND EQUIPMENT. _*_�F. EXHAUST FANS SHALL BE LOCATED A MINIMUM OF 10'-0" HORIZONTAL DISTANCE FROM FRESH AIR INTAKES OR SHALL HAVE A VERTICAL SEPARATION OF 3'-0" ABOVE FRESH AIR INTAKES. G. CONTRACTOR SHALL INSTALL THE FOLLOWING EQUIPMENT PROVIDED BY THE OWNER: '—l. EXHAUST HOOD WITH PRE -PIPED ANSUL SYSTEM, HANGER BRACKETS AND GAS SOLENOID VALVE. CONTRACTOR SHALL PROVIDE AND INSTALL COMMERCIAL KITCHEN GREASE EXHAUST DUCTWORK THAT SHALL BE THE FOLLOWING TYPE: 16 GAUGE BLACK STEEL DUCTWORK, ALL JOINTS AND SEAMS SHALL BE WELDED LIQUID TIGHT. ALL ELBOWS SHALL BE RADIUS AND THE DUCT SYSTEM SHALL BE FABRICATED SO AS TO HAVE NO DIPS, TRAPS, OR POCKETS WHERE GREASE CAN ACCUMULATE. PROVIDE APPROVED ACCESS PANELS FOR INSPECTION AND CLEANING AT ALL CHANGES IN DIRECTION, AND TO GAIN ACCESS TO THE BYPASS DAMPER AND FUSIBLE LINK WHERE APPLICABLE. INSULATE EXTERIOR OF DUCT WITH INSULATION APPROVED BY LOCAL AUTHORITY TO REDUCE CLEARANCE TO COMBUSTIBLES TO 0". PROVIDE FIRE RATED ACCESS PANELS IN THE DUCT ENCLOSURE AT ALL DUCT ACCESS PANEL LOCATIONS. MAINTAIN 1/4" PER FOOT SLOPE TOWARDS THE HOOD ON ALL HORIZONTAL GREASE DUCT. INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 96. 1. CONTRACTOR SHALL PROVIDE DUCTWORK SUPPORTS AND HANGERS PER CODE. PROVIDE THREADED ROD, WASHERS, AND NUTS FOR CONNECTION TO HOOD HANGER BRACKETS. J. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING PROPOSED FABRICATION AND INSTALLATION COORDINATED WITH EXISTING FIELD CONDITIONS AND OTHER TRADES. K. CONTRACTOR SHALL ENSURE EXISTING HVAC UNITS ARE INTERLOCKED WITH NEW FRYER EXHAUST FAN FOR CONTINUOUS OPERATION WHEN EITHER UNIT OR FAN IS RUNNING. GENERAL NOTES C THE EQUIPMENT ROUGH -IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE AND SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER, OWNER AND/OR THE EQUIPMENT ROUGH -IN DRAWINGS. IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN ON THE PLAN. THEREFORE, THE ARCH ITECT/ENGI NEER SHALL BE IMMEDIATELY NOTIFIED, PRIOR TO CONSTRUCTION OF ANY DEVIATIONS FROM WHAT IS SHOWN OR IMPLIED ON THESE DRAWINGS. FAILURE OF THE APPROPRIATE CONTRACTOR TO VERIFY ROUGH -INS OR THEIR LOCATIONS SHALL PACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR ADDITIONAL ROUGH -INS DIRECTLY UPON THE CONTRACTOR. MECHANICAL PLAN 1/4"=V-0" �j NEW ROOF MOUNTED NEW FRYER EXHAUST FAN TO BE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR ON FLAT ROOF. 510 CFM AT 1500 FPM. PROVIDE CURB EXTENSION SO TOP OF EXHAUST FAN IS LEVEL WITH EXISTING R90FTOP UNIT. VERIFY IN FIELD. 0,y"�ao L-keve� C-�ap 2 HINGED ACCESS PANEL FOR NEW FRYER EXHAUST FAN, SHOWN FOR REFERENCE. CONTRACTOR AND YUM CONSTRUCTION MANAGER SHALL COORDINATE LOCATION OF NEW FRYER EXHAUST FAN TO MAINTAIN A MINIMUM OF 10'-0" FROM ANY FRESH AIR INTAKE. NEW TYPE I EXHAUST HOOD - PART OF WINGSTREET PACKAGE #WSIB3-36-FLAT.K3. SEE DETAILS ON DRAWING SHEET M2.0 AND M3.0. G.C. TO PROVIDE AND INSTALL 24 GA. STAINLESS STEEL BEHIND HOOD AND 18" OUTSIDE OF PERIMETER OF HOOD FOR CONSISTENCY AND CLEANABILITY. CONTRACTOR TO LOCATE NEW ANSUL PULL STATION FOR NEW FRYER HOOD AT LEAST 10'-0" TO 20'-0" AWAY FROM FRYER HOOD. T'x7" EXHAUST DUCT WITH WELDED SEAMS UP FROM EXHAUST RISER ON HOOD TO EXHAUST FAN EF-4 ROOF. PROVIDE A DUCT ENCLOSURE FOR THE GREASE DUCT ABOVE CEILING PENETRATION TO THE OUTSIDE OF BUILDING. A ONE -HOUR ENCLOSURE IS REQUIRED IN ALL BUILDING AND A TWO-HOUR RATED ENCLOSURE ON TYPE 1 OR 2 FIRE RESISTIVE BUILDINGS (AS PER 2004 FLORIDA MECHANICAL CODE 507.9). REFER TO GREASE EXHAUST DUCT DETAIL ON DWG. M2.0 FOR ADDITIONAL INFORMATION. 16 GAUGE BLACK STEEL DUCT WITH LIQUID TIGHT CONTINUOUS EXTERNAL WELD. PROVIDE CLEAN -OUT ACCESS. WRAP WITH ONE (1) LAYER OF 3M FIRE BARRIER DUCT WRAP 15A, 1-1/2" THICK WITH 3" PERIMETER AND LONGITUDINAL OVERLAPS. PROVIDE ONE OR TWO HOUR FIRE RESISTIVE RATING AND ZERO CLEARANCE TO COMBUSTIBLES AT OVERLAP OR COLLAR. 3M FIRE BARRIER DUCT WRAP IS LISTED BY OMEGA POINT LAB DESIGN NUMBER GD532F AND Ul. #1978. INSTALL PER MANUFACTURER'S INSTRUCTIONS. REFER TO GREASE EXHAUST DUCT DETAIL ON DWG. M2.0 FOR ADDITIONAL INFORMATION. CONTRACTOR SHALL REMOVE EXISTING SUPPLY AIR DIFFUSER AND REPLACE WITH A TITUS MODEL #8FF OR METAL-AIRE MODEL #7650 PERFORATED DISCHARGE PANEL DIFFUSER WITH A HINGED FACE AND NO FILTER. FIELD VERIFY LOCATION. LOCATE A MINIMUM OF 6.4, AWAY FROM NEW FRYER HOOD. COORDINATE EXACT LOCATION WITH CEILING GRID & LIGHT FIXTURES. MODIFY S.A. DUCT AS REQUIRED. INSTALL PER MANUFACTURERS INSTRUCTIONS. (-1-0-) CONTRACTOR SHALL VERIFY EXISTING THERMOSTAT QUANTITY AND LOCATIONS. REWIRE AS PART OF MAKEUP AIR INTERLOCK. COORDINATE WITH ELECTRICAL CONTRACTOR. - SEE DETAIL 2 ON SHEET E1.0 FOR TYPICAL WIRING DIAGRAM. _11-) NEW CONDENSING UNIT TO BE LOCATED AT SITE OF EXISTING CONDENSING UNIT FOR EXISTING STAND-ALONE ICE MACHINE TO BE REMOVED. PROVIDE NEW REFRIGERANT PIPING AS REQUIRED DUE TO NEW ICE MACHINE INSTALLATION. ROUTE NEW PIPING TO OPENING IN ROOF. VERIFY EXISTING ROOF CONDITIONS (CRICKETS, FANS, ROOFTOP UNITS) AND ADJUST PIPE ROUTING AS REQUIRED. INSTALL AS PER MANUFACTURER'S INSTRUCTIONS. REFER TO MULTIPLE PIPE FLASHING DETAIL, E/M1.0 AND SLEEPER SUPPORT DETAIL, F/M1.0 FOR INFORMATION CONTRACTOR SHALL VERIFY IN FIELD LOCATION OF EXISTING ROOFTOP EQUIPMENT (SATELITES, ROOFTOP UNIT, ETC.) AND ADJUST NEW FRYER EXHAUST FAN LOCATION AS PER ACTUAL SITE CONDITIONS. CD EXISTING ROOF PARAPET SHOWN FOR REFERENCE. � 6 o� w a4 KEY NOTES J a 0 0 c) LL a: w UJ 1� M X: U. 04.24.08 HAND SINK ADDITION CONTRACT DATE: 03.21.08 BUILDING TYPE: ???7.??' STORE NUMBER: 95343 ARCV NUMBER: 080406 6548 GALL BLVD. ZEPHYRHILLS, FIL 33542 HVAC PLAN & SPECS. m 1 0 PLOT DATE: 02.19.08 14� �\)'Nmuv_ UN HOOD INSTALLATION: 1. Installation of ventilation system will be by contractor. Exhaust collars will be factory installed. Hoods shall be installed in accordance with NFPA 96, IMC 2003 and all other applicable local, state and national codes. Special attention must be given to codes regarding clearance to surrounding combustible and limited combustible (NFPA 96) construction (walls, ceilings, etc.). 2. Contractor is responsible for drilling retaining bolt holes into wall mounting flanges at top and bottom of hood and providing the hardware. 3. Ceiling enclosure furnished by hood manufacturer will be attached in the field by contractor. 4. Ductwork between factory mounted hood collar and factory supplied roof top curb transition will be furnished by contractor. AIR FLOW REQUIREMENTS 1 . AVTEC is not liable for improper function of the system caused by changes in the system static pressure or over all air flow volume from the original specified design points. Exhaust duct air flow velocity must be between 1500 and 2200 FPM with welded duct. 2. Exhaust air flow must be balanced with other exhaust & make-up air systems and the store HVAC systems upon installation. Test & Balance is the responsibility of the installing contractor. Fan operating speed, belts and pulleys should be rechecked after 60 days to ensure proper performance. Static pressure values are given for the hood only and do not include ductwork and rooftop fans. 3. Air flows are noted in Mechanical schedule. 4. AVTEC RESERVES THE RIGHT TO CHANGE SPECIFICATIONS TO MEET CODE OR JOB REQUIREMENTS. CONSTRUCTION 1. Hood shall be fabricated in accordance with NFPA Bulletin #96 and shall bear the NSF Seal of Approval. Hoods shall be listed under UL 710 EXHAUST HOODS FOR COMMERCIAL COOKING EQUIPMENT UL File # M H 18450. FIRE EXTINGUISHING SYSTEM 1. Factory installed fire extinguishing system piping supplied and installed in accordance with NFPA 96 by FIRE SUPPRESSION INSTALLER. 2. Caution: Fire extinguishing system installed on site must be done in accordance with AVTEC to insure that pipe does not interfere with hood performance. Improper installation may void UL listing. WIRING NOTES 1. Fan controls (e.g. On/Off switch), thermal overload protection and wiring for fan to be furnished by Electrical contractor. 2. Ansul, fan and fryer interlock shall be wired by Electrical contractor according to schematic furnished with electrical drawings. EXHAUSTFAN EXIST. ROOF TOP UNIT NEW CURB EXTENSION ANSUL SYSTEM, WALL MOUNTED EXTEND CURB SO THAT EXHAUST FAN DISCK4RGE 6 AT SAME HE1GHT AS EXISTING ROOFTOP UNIT ROOF LINE COUNG LINE AT W-00 L J L _J L J L -JUI L_j LJ LJ�j 0 GAIM M= MM W/LIQUID MONT CONT WERNAL, WELD PROVIDE CLEAN -OUT ACCEM WRAP WITH ONE (1) LAYER OF 3M FIRE BARRIER DUC!T WRAP 15A. 1 1/2- THICK WITH S' PERIMETER AND LONGITUDINAL OVERLAP& PROWDES ONIE OR M HOUIR FM RESISTIVE RATM AND ZERO CLEMANCE 70 COMBLISTIBLES AT OVERLAP OR COLLAFL 3M. FIRE BAMER DUCT WRAP IS LISTED BY OMW POffiT LAB OEM NQ GD5W AND k,19K INSIALL PER MANIUFACTUREI;rS RASTRuenoms. 991 General Installation Guidelines: 1 . Measure and mark the desired height and centerline of the hood on the wall. (Refer. to the architect's plan for the dimension) The height of the plate shelf above the fixed floor is a critical dimension 2. Secure the wall mounting flanges at top and bottom of hood to a minimum of two (2) or more wall studs.. 3. Field measure and layout ductwork as close as possible to the mechanical drawing. 4. Position the fabricated ductwork to match the factory mounted exhaust collar location above the hood. 5. A continuous liquid tight weld to the collar transition and ductwork will meet any and all code requirements. 6. Connect the ductwork to the factory supplied curb transition terminating at the top of the vented curb extension below the fan base. Do not terminate the ductwork at the roof -line. Ductwork must be welded with a continuous liquid tight weld at the factory supplied exhaust fan curb transition. 7. Attach factory supplied hinge kit and grease trough to fan curb per NFPA96-2004. 8. Enclose duct as required by local, state and national fire protection and mechanical codes observing in particular the clearance to combustible provisions. 9. Connect and test the hoods fire suppression system. Only professionally qualified persons should perform these functions. 10, Check to ensure proper placement of the grease filters and grease cup. 11. Remove the protective PVC coating from all of the metal surfaces prior to use of the appliances. 12. Run check the exhaust fan and fryer interlock. 13. Certified Test & Balance contractor must take FPM readings across the filter bank and confirm that exhaust fan is operating at or above the exhaust CFM design point . ANY AIR FLOW LEVEL BELOW DESIGN POINT IS NOT ACCEPTABLE. Do not accept motor RPM readings as a substitute for filter airflow levels. 14. Call for functional inspections as required. 15. Apply fabricated trim (contractor supplied) to the ceiling and wall as required. Factory supplied shroud (enclosure panels) from top of hood to ceiling should be screwed to angle at top edge of hood with self -tapping SS screws. 16. Clean the surfaces of the hood with a mild detergent using care not to scratch or dent the surface. 17. Contractor responsible relocating HVAC diffusers a minimum of 6-feet from fryer hood and cover discharge with perforated panel. 18. Contractor responsible for relocating HVAC returns a minimum of 10-feet from fryer hood. 19. Contractor responsible for Store Test & Balance of HVAC and all kitchen exhaust and supply fans according to the Mechanical Air Flow Balance Schedule. ROOF LINE NEW CURB EXTENSION CW" F',04&]W QUETWI&W At A. THE GREASE EXHAUST SYSTEM SHALL BE CONSTRUCTED OF BLACIC STEEL NOT LESS THAN 18 CA UP TO 4 SO. Fr. ARE06 14 GOL ABOVE 4 SIL FT. WITH CONTINUOUS GFEME-70ff AND WATER-10ff WELDS AT ALL JOINTS AND SEAMS. 'THE SYSTEM SHALL BE 90 CONSTRUCTED THAT NO GREASE WILL BECOME POOMM IN ANY PORTION THEREOF AND S1-IALL SLOPE AT NOT LESS 7HAN I/e PER FOOT F MWONIAL LENGTH UNDER 73 FEET LONG OR 10 PER I= F OWM 75 FW, BACK TO THE HOW OR AS REQUIRED BY THE LOCAL AUTHORMEL B. OPENINGS IN DUCT SHALL COWORM TO CODE REMREMENTS AND SHALL BE PROVIDED FOR COMPLETE AND THOROUGH CLI04NING OF DUCT SYSTEM. C. PROVIDE THE 'PENETPATOIr GREASE DUCT CLEAN-011T ACCESS DOORS MANUFACTURED BY FUME GARD. INC. (OR EOWALEIM AT EYERY CIWM OF DIREMM. D. GREASE EXHAUST DUCT SHALL BE WRAPPEI) WITH ONE (1) LAYER OF 3M FIRE BAmm mu WRAP i a& 1 1/20 THICK WITH 3" ]PERIMETER & LONGITUDINAL. OVERLAP& PROVIDES ONE OR M HOUIR FIRE RESISTWE RATING AM ZERO CLE4RAN10E TO COMOMBLES AT OVERLAP OR CMLAIL 3M FIRE BARM DUCT WRAP IS LISTED BY OMWA POINT LAB DESIGN NO. GD532F AND UL 197& IMIALL PER MANUFACrUREWS INSTRUCTION& FRONTV% RECEPTACLES 04M ARE FOR REFERENCE ONLY. WE SHEET E-1 FOR ACTUAL LOACTIONS AND ADDITIONAL INFORMATION. INSTALLATION NOTES EXHAUSTFAN EXIST. ROOF TOP UNIT SIDE VIEW GREASE EXHAUST DUCT DETAIL N.T.S. F F INLET WATER OVERFLOW GJ T Sq. OD ROOF CURB CABLE _T C B -A THEEOUIPMENTROLIGHlIV17E4fSAND7HEIRDIMFJVSICVVEDLOCA77ONSFORALL CONNEC77ONSAAE ACCURA 7E 70 7HEBESTOFOURKACKEDGEAND Sq&L BE VOWI-7ED W71-1 THEEOUIPMENT SUPPLIER OANERANDA2R T1-1EEi0t11PMEJVTR0UG*1N DR4 WAIGS IN SOMEINSTANCES THE OWNER ORStIADI-1,ERAMYAfAKESUBSTflUMNS OR THEEOUIPMEW17EMAMYVARYR?OMWATISSI-IOPW OW 7REPLAN THEREFORE, THEARCHITECTIENGINEER&MLL BEIMMED147FLYN077RED, PRIOR TO CONS77?UC77CVV OF AIVYDEL44 7701VS FROM " TIS SHOWN OR IMPLIED CVV THESEDR4 WNGS FAILURE OF THEAPPROPRA4 TE COATM C70R TO VERIFYROUGHLINS OR THEIR L OCA nONS SH&L PACE THERESPMSIBILITYFORANYSUBSEOUEWRELOC477OiVAIVDIORADD1770AW ROUGH -INS DIREC 7 L Y UPON THE C ON 7 RA C TOR. GREASE TROUGH DIMENSIONS MARK QTY. 1 DESCRIPTION A B C EF,3 1 1 KEY WAY GREASE TROUGH 5 12 6 GREASE TROUGH DETAIL N.T.S. A PERFORMANCE MARK QTY I COOK MODEL FLOW (CFM) SP nwc) FAN RPM Bhp (HP) dBA SONES EF-3 1 150VH4B 510 1.0 1465 0.32 52 10.9 The UL Listing Number for the exhaust fan is MH1 1109 (listed to UL Standard 762). MOTOR INFORMATION MARK HP RPM I VoWPh/Hz JENCLOSURE EF-3 1/3 1465 115/11/60 ODP DIMENSIONS (inches) EF-3 A 20.9 B 34.69 C 27.5 G 2 T S(3. I Roof Ope 19.5 Unit Wflh 156 EXHAUST FAN DETAIL N.T.S. B HINGE BASE DIMENSIONS MARK QTY. DESCRIPTION A B C CABLE OD Curb EF-3 1 24T 23.4 2.25 1.25 37 1 22.5 HINGE BASE DETAIL N.T.S. C J 0 _j 0 0 IL W 0 o W Ej= U. CONTRACT DATE: 03.21.08 BUILDING TYPE: ??7??? STORE NUMBER: 95343 ARCV NUMBER: 080406 6548 GALL BLVD. ZEPHYRHILLS, FL 33542 FRYER HOOD & DUCT DETAILS M210 PLOT DATE: 02.19.08 FACTORY SUPPLIED DUCT —TO —FAN CURB TRANSITION WITH 10 FLANGE AT TOP AND BOTTOM WELDED TO 7X7 DUCTWORK BY CONTRACTOR IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND NATIONAL CODES. — OPTIONAL 5:12 PITCHED CURB STANDARD PACKAGE INCLUDES FLAT CURB. FLAT CURB WILL BE PROVIDED UNLESS SPECIFIED OTHERWISE FACTORY MOUNTED 12X4 TRANSITION TO 7X7 DUCT CONNECTION W/ 1- PERIMETER FLANGE TOP CEILING LINE AT 8'-0" A.F.F. AREA FOR FIRE U PRESSION� PREPIPING DROP FOR FRYER PROTECTION 30-1 /2- PAN RACK RETENTION CUP I 35" 65 1 /2" CRITICAL DIM. SIDE VIEW REMOVABLE BOTTOM SIDE SKIRTS 12" SIDE ELEVATION VIEW " 47" 47" 30-1 /2" AFF EXHAUSTFAN FLAT ROOF CURB 200 TALL; 22" SQ. VERIFY DETECTOR BRACKET DOESN'T BLOCK DUCT.---,, 1 0 0 \• 0 0 1 MAX. ROOF OPENING 19 1/2" SQUARE 7"X7" GREASE EXHAUST DUCT FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. SHROUD FOR HOOD SUPPLIED BY FACTORY; INSTALLED BY CONTRACTOR UL LISTED 3" INSULATED AIR GAP ZERO CLEARANCE TO COMBUSTIBLES 8" 8"- PLAN VIEW HOOD # 1 OF 1 MODEL VNP31036 LENGTH (IN): 36" WIDTH (IN): 31- HEIGHT (IN): 47" EXHAUST CFM: 510 EXHAUST SP AT COLLAR: EXHAUST FPM: 1500 EXH. COLLAR SIZE: 12" X 4" FILTERS: ( 3) 12" X 16" FIRE SUPPRESSION: ANSUL—R102 CONTROL SWITCH: CONTACTOR SUPPLIED, SEE ELECTRICAL SHEETS FILTER TYPE: RESEARCH PRODUCTS ALUMINUM FILTER FILTER TYPE: ALUMINUM NET FILTER AREA: 2.22 VELOCITY THRU FILTERS: 229.72 FPM HOOD WEIGHT. 143 LBS. I OPTION DESCRIPTIONS: 18 GA. ALL 304 CONSTRUCTION (2) UL LISTED GLOBE LIGHTS (3) 12" X 16" RESEARCH PRODUCTS ALUM FILTER 3in. UL LISTED INSULATED REAR AIR SPACE SHROUD SHIPPED LOOSE 4" x 12" COLLAR TRANSITION TO 70 FLANGED DUCT CONNECTION DUCT -TO -FAN CURB TRANSITION WITH 1" FLANGE AT TOP AND BOTTOM AVT[C INDUSTRIES ®L m L 525 S. COLDWATER RD. NSJ W MDMAN�Mau mvim MODEL NO.: VNP31036 40OF MAX COOKING TEMP 60OF MAX COOKING TEMP 70OF MAX COOKING TEMP MIN EXH CFM/Fr 90 119 N/A MAX SUP CFM/Fr N/A N/A N/A MAX MW OMW -6" -69 N/A SIDE OVERHUNG 0" 0" N/A HOOD & Coaa EOU"WENT MAX 30" 30" N/A FOR USE WITH UL CLASSIFIED AL OR STEEL GREASE FlLTERSI REPLACE FUMBLE LINK WITH UL LISTED 3-20LB. 165E 11Nly * This Hood is a Type 1 UL Listed NON —Canopy ventilator. UL Flle # MH-18450 (listed to UL Standard 710). * This ventilator meets or exceeds the IMC 2000 requirements of 507-14 and the 2003 UMC requirements of 508.4.2. * Minimum UL Listing requirements are listed above. * The UL Listing Number for the exhaust fan is MH11109 (listed to UL Standard 762). ITEM QTY DESCRIPTION FLOW PTS 1 2 3N APPLIANCE NOZZLE 3EA — 6PTS 4 3 6170TUR BRACKET N/A TOTAL FLOW POINTS 8 SYSTEM SIZE 3 GALLON 3 GALLON MECHANICAL RELEASE REQUIRED BY OTHERS NOTE: ALL PIPE TO BE 3/80, EXHAUST COLLAR 12x4 ALL DETECTORS REQUIRE FUSIBLE j LINKS l ML—STYLE FUSIBLE LINK ANSUL# 56816 OR EQUAL WITH TEMP. RATING 500—DEGREE F or 260—DEGREE C ISOMETRIC VIEW FACTORY SUPPLIED SHROUD SHIPPED LOOSE; ATTACHED BY CONTRACTOR r-----------------------------------------------I I I ' FACTORY MOUNTED 12X4 ' TRANSITION TO 7X7 DUCT CONNECTION W/ 10 PERIMETER ; M AK11%V TAC 36" FRONT VIEW 18" 12x4 EXHAUST COLLAR TRANSITION TO 7x7 DUCT 3:L N O 4" 31N 12"i 0 0 0 PLAN VI EW THE EQUIPMENT ROUGH -IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL rnNNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE AND SHALL BE ED WITH THE EQUIPMENT SUPPLIER, OWNER AND/OR THE EQUIPMENT ROUGH -IN INGS. IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS E EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN ON THE PLAN. THEREFORE, RCHITECT/ENGINEER SHALL BE IMMEDIATELY NOTIFIED, PRIOR TO CONSTRUCTION IY DEVIATIONS FROM WHAT IS SHOWN OR IMPLIED ON THESE DRAWINGS. FAILURE IE APPROPRIATE CONTRACTOR TO VERIFY ROUGH -INS OR THEIR LOCATIONS SHALL FHE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR ADDITIONAL +INS DIRECTLY UPON THE CONTRACTOR. FIRE SUPPRESSION PIPING DETAILS N.T.S. FACTORY SUPPLIED SHROUD SHIPPED LOOSE; ATTACHED BY CONTRACTOR :12" x 4" FACTORY i i MOUNTED COLLAR TRANSITION TO 7x7 FLANGED DUCT "FIELD DRILL ;CONNECTION (1FOR " TOP FLANGE) MOUNTING TO STRUCTURE YVI 1%OM JILNV Jf1%111%I w7 FIELD DRILL FOR MOUNTING TO STRUCTURE ISOMETRIC VIEW EXHAUST HOOD DETAILS N.T.S. 04.24.08 HAND SINK ADDITION 0 A CONTRACT DATE: 03.21.08 BUILDING TYPE: ?????? STORE NUMBER: 95343 ARCV NUMBER: 080406 6548 GALL BLVD. ZEPHYRHILLS, FL 33542 EXHAUST HOOD DETAILS M3,0 PLOT DATE: 02.19.08 EXTEND NEW 1-1/4" GAS PIPING TO EXISTING PIPING. J CONTRACTOR SHALL ENSURE THAT POINT OF i l CONNECTION IS AT LOCATION IN PIPE THAT WILL ACCEPT AN ADDITIONAL 160 MBH LOAD. AFTER VERIFYING EXISTING CAPACITY, IF EXISTING SYSTEM WILL NOT ACCOMMODATE NEW LOAD, CONTRACTOR MUST COORDINATE WITH LOCAL UTILITY FOR INCREASED SERVICE CAPACITY. ROUTE GAS PIPING ON FACE OF WALL WHEN ALLOWED BY AHJ DIRT LEG GAS COCK 1-1/4" MECHANICAL SOLENOID VALVE BELOW CEILING 1-1/4" 160 MBH INSTALL QUIK DISCONNECT TO FRYER GAS COCK (TYPICAL) - GAS RISER PLAN N.T.S. I E CONNECT TOBER EXISTING PLUM��w VERIFY LOCATI I XIST. I 1 /2"CW 1/2"CW I EXIST. 1/2"HW I 11/2"HW I I NEW HAND SINK W/FOOT PEDAL NEW HAND SINK W/FOOT PEDAL WATER RISER PLAN N.T.S. I EXIST. 1 1/2" I VENT NEW I NEW NEW HAND SINK I HAND -IjSINK 1 1/2" SAN. P.O.C. EXIST. 54FIN. 1 1/2" EXIST. FLR. SAN. 2"SAN. N EW`_- 3 THE EQUIPMENT ROUGH -IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE AND SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER, OWNER AND/OR THE EQUIPMENT ROUGH -IN DRAWINGS. IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN ON THE PLAN. THEREFORE, THE ARCHITECT/ENGINEER SHALL BE IMMEDIATELY NOTIFIED, PRIOR TO CONSTRUCTION OF ANY DEVIATIONS FROM WHAT IS SHOWN OR IMPLIED ON THESE DRAWINGS. FAILURE OF THE APPROPRIATE CONTRACTOR TO VERIFY ROUGH -INS OR THEIR LOCATIONS SHALL PACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR ADDITIONAL ROUGH -INS DIRECTLY UPON THE CONTRACTOR. A. ALL WORK SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS OF CITY, AND/OR STATE. B. ALL AUTHORITIES HAVING JURISDICTION SHALL BE NOTIFIED AT LEAST THREE WORKING DAYS PRIOR TO COMMENCEMENT OF WORK. C. ALL PIPING SHALL BE ROUTED IN THE SUSPENDED CEILING SPACE UNLESS OTHERWISE INDICATED. ALL PIPING EXPOSED TO VIEW SHALL BE ROUTED AS HIGH AS POSSIBLE AND TIGHT TO THE UNDERSIDE OF THE STRUCTURAL STEEL. D. EXPOSED PIPING IN FINISHED AREAS SHALL BE CHROME PLATED WITH CHROME PLATED ESCUTCHEON AT PIPE ENTRY TO FINISHED AREA. E. SLEEVE OR CORE -DRILL FLOOR SLABS, WALLS, ETC. AS REQUIRED FOR PIPING AND FIRE -STOP OPENING AROUND PIPE VERIFY LOCATION OF STRUCTURAL BEAMS, JOISTS, ETC. BEFORE DRILLING. F. ALL OPENINGS IN DRAINAGE AND/OR VENT SYSTEMS AS A RESULT OF INSTALLATION ROUGH -IN SHALL BE PROTECTED WITH A TEST PLUG THAT IS SECURELY LOCKED IN PLACE UNTIL FINAL FINISHED CONNECTIONS ARE INSTALLED. G. ALL PIPING SHALL BE CONCEALED IN WALLS AND BEHIND FIXED FURNISHINGS UNLESS OTHERWISE INDICATED. H. WHEREVER FOUNDATION WALLS, OUTSIDE WALLS, ROOF, ETC. ARE PENETRATED FOR INSTALLATION OF SYSTEMS, THEY SHALL BE PATCHED TO MATCH EXISTING CONSTRUCTION AND SEALED WEATHER TIGHT. WORK SHALL BE PERFORMED BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE TRADES. F I. ALL PIPING SHALL BE RUN PARALLEL TO BUILDING LINES AND SUPPORTED AND ANCHORED AS REQUIRED TO FACILITATE EXPANSION AND CONTRACTION. ALL PIPING SHALL BE CONCEALED EXCEPT IN UNFINISHED SPACES. INSTALL AS REQUIRED TO MEET ALL CONSTRUCTION CONDITIONS AND TO ALLOW FOR INSTALLATION OF OTHER WORK INCLUDING DUCTS AND ELECTRICAL CONDUIT. AT ALL CONNECTIONS BETWEEN FERROUS PIPING AND NONFERROUS PIPING, PROVIDE AN ISOLATING DIELECTRIC UNION. J. PROVIDE ALL FITTINGS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY TO FACILITATE THE PLUMBING SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT INDICATED. K. ALL DRAINAGE PIPING SHALL BE UNIFORMLY PITCHED, 1/4" PER FOOT UNLESS OTHERWISE REQUIRED BY EXISTING CONDITIONS. L. PROVIDE A COMPLETE SYSTEM OF COPPER, STEEL OR PLASTIC VENT RISERS ABOVE FLOOR. ALL VENTS SHALL BE CARRIED THROUGH THE ROOF WITH FLASHING. PLASTIC IS PREFERRED BY OWNER IF ALLOWED BY AUTHORITIES. PLASTIC PIPING, IF PERMITTED, SHALL NOT BE FOAM CORE P.V.C. M. CONDENSATE AND INDIRECT DRAIN PIPING SHALL BE COPPER OR PLASTIC TUBING. PLASTIC IS PREFERRED BY OWNER IF ALLOWED BY AUTHORITIES. PLASTIC PIPING, IF PERMITTED, SHALL NOT BE FOAM CORE P.V.C. N. PROVIDE CLEAN -OUTS AT THE END OF EACH HORIZONTAL RUN, AND AT THE BASE OF ALL VERTICAL WASTE AND DRAIN PIPES. CLEAN -OUTS SHALL BE OF THE SAME SIZE AS THE PIPES THEY SERVE. SANITARY RISER PLAN N.T.S. I G 17 � N NEW 1-1 /4"GAS , I € E 14 4 5 ..`s, 11 I I I 1 I I I 1 O. HOT AND COLD WATER PIPING SHALL BE TYPE "L" COPPER PIPE ABOVE GRADE AND TYPE "K" COPPER PIPE BELOW GRADE, FITTINGS AS REQUIRED BY LOCAL AUTHORITIES. PROVIDE WATER HAMMER ARRESTORS WADE "SHOKSTOP" MODEL NO. W-5 THROUGH W-100, SIZE AS INDICATED BY MANUFACTURER, WHERE SHOWN ON THE DRAWINGS. INSTALL STOP VALVE IN AN ACCESSIBLE LOCATION IN EACH WATER SUPPLY TO EACH FIXTURE. P. INSULATE ALL HOT AND COLD WATER PIPING BOTH VERTICALLY AND HORIZONTALLY, IN CEILING AND CONCEALED IN WALLS COMPLETELY. PROVIDE 1" PREFORMED FIBERGLASS ASJ-VB, FLAME SPREAD 25, SMOKE DEVELOPED 50, ASTM C-547. Q. PIPING ROUTED IN EXTERIOR WALLS SHALL BE ROUTED ON THE WINTER -WARM -SIDE OF THE BUILDING WALL INSULATION. R. ACCESS PANELS SHALL BE PROVIDED WHERE CONCEALED CONTROL DEVICES, VALVES, ETC. ARE CONCEALED WITHIN WALLS. WHERE ACCESS FOR ADJUSTMENT AND MAINTENANCE IS POSSIBLE THROUGH LAY -IN SUSPENDED CEILINGS, ACCESS PANELS ARE NOT REQUIRED. �S. PROVIDE A COMPLETE NATURAL GAS PIPING SYSTEM AS NOTED ON THE DRAWINGS. PIPE AND FITTINGS SHALL BE AS REQUIRED BY LOCAL AUTHORITIES. PROV IDE ALL UNIONS SHUT-OFF VALVES AND DIRT LEGS REQUIRED BY NFPA-54 AND GOVERNING LOCAL CODES. PROVIDE ALL TEST, METERS, INSPECTIONS, HANGERS AND EQUIPMENT CONNECTION REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. PAINT PIPING ON ROOF WITH TWO COATS OF RUST RESISTANT OUTDOOR PAINT, T. DRAINAGE PIPING UNDERGROUND SHALL BE CAST IRON OR PLASTIC PIPE AND FITTINGS. PLASTIC IS PREFERRED BY OWNER IF ALLOWED BY AUTHORITIES. PLASTIC PIPING IF PERMITTED, SHALL NOT BE FOAM CORE P.V.C. U. DRAINAGE PIPING INSIDE THE BUILDING SHALL BE CAST IRON OR PLASTIC PIPE AND FITTINGS. PLASTIC IS PREFERRED BY OWNER IF ALLOWED BY AUTHORITIES. PLASTIC PIPING, IF PERMITTED, SHALL NOT BE FOAM CORE P.V.C. V. EXISTING CONDITIONS ARE BASED ON "AS -BUILT" DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. W. CONTRACTOR SHALL VERIFY ALL SIZES, LOCATIONS, AND DEPTHS OF EXISTING PLUMBING PRIOR TO CONSTRUCTION. X. PVC SHALL BE USED FOR DRAIN, WASTE & VENT SYSTEMS WHENEVER ALLOWED BY THE AUTHORITIES HAVING JURISDICTION (AHJ). Y. PROVIDE AIR CHAMBERS WHEN WATER HAMMER ARRESTORS ARE NOT ALLOWED (CHICAGO AREA). Z. PROVIDE NEW CONDENSATE LINE FROM EVAPORATOR COIL IN COOLER/ FREEZER TO APPROVED RECEPTACLE. INSTALL APPROVED RECEPTACLE WHEN REQUIRED BY CODE. ,mim� GAS PIPING SHALL BE SCHEDULE 40 BLACK IRON STEEL. CONTRACTOR SHALL PAINT GAS PIPING TO MATCH COLOR OF EXPOSED SURFACES. BB. "OPTIONAL VEGGIE SINK": INSTALL AERO VEGGIE SINK WHEN REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION. INSTALL MODEL: N-909 FOR APPLICATIONS WHERE DRAINBOARD IS LOCATED ON THE RIGHT. INSTALL N-910 WHERE DRAINBOARD IS NEEDED ON LEFT SIDE. GENERAL NOTES I D I I 7 6 9 10 O TI- ...5 I I I € F t 51 11 i c Q EXISTING GAS PIPING FROM EXISTING GAS METER. CONTRACTOR SHALL VERIFY IF EXISTING GAS METER CAN HANDLE AN INCREASE OF 240.0 MBH. O 1-1/4" GAS PIPING DOWN TO FRYER BELOW. DROP DOWN TO 12" AFF BEFORE HORIZONTAL TRANSITION, 1" QUIK DISCONNECT FOR NEW FRYER AT 160.0 MBH TOTAL. REFER TO GAS RISER E/P1.0 DETAIL D/P2.0 FOR INFORMATION. ® PROVIDE AND INSTALL NEW "HANDS FREE" KIT AT SITE OF EXISTING HANDSINK. CONNECT TO EXISTING WATER SUPPLY LINES. REFER TO PLUMBING NOTES #4, #5, AND DETAIL B/P2.0 FOR ADDITIONAL INFORMATION. (aDEXISTING 3" HUB DRAIN SHOWN FOR REFERENCE. FIELD VERIFY EXACT LOCATION. © NEW BEVERAGE DISPENSER TO REPLACE EXISTING BEVERAGE DISPENSER IN DINING AREA. LOCATE AS SHOWN AFTER COMPLETION OF NEW DINING ROOM CONSTRUCTION BY PEPSI SUPPLIER. PROVIDE NEW INDIRECT WASTE PIPING AND ROUTE TO EXISTING 3" HUB DRAIN WITH CODE REQUIRED AIR GAP. O NEW ICE MACHINE TO BE LOCATED ABOVE NEW BEVERAGE DISPENSER IN DINING AREA AS SHOWN AFTER COMPLETION OF NEW DINING ROOM CONSTRUCTION. PROVIDE NEW INDIRECT WASTE PIPING AND ROUTE TO EXISTING 3" HUB DRAIN WITH CODE REQUIRED AIR GAP. PROVIDE NEW 1/2" FILTERED C.W. PIPING FROM SYRUP BUNDLE CONNECT TO EXISTING FILTERED WATER LINE FOR ICE MACHINE. FIELD VERIFYLOCATION. Q EXISTING BAG-N-BOX SHOWN FOR REFERENCE. O NEW CARBONATOR TO BE LOCATED AS SHOWN AT DRINK DISPENSER. CONNECT TO EXISTING FILTERED WATER PIPING FROM EXISTING SYRUP BUNDLE AS REQUIRED. BACKFLOW PREVENTOR SHALL BE INSTALLED AT CARBONATOR WITH PIPING DOWNSTREAM THEREFROM SHALL NOT BE AFFECTED BY CARBON DIOXIDE GAS. FIELD VERIFY EXACT SIZE AND LOCATION. 10 CONTRACTOR SHALL PROVIDE AND INSTALL A DOUBLE CHECK VALVE BACKFLOW PREVENTOR WITH ATMOSPHERIC VENT (WATTS SD-3 OR EQUAL) INSTALL UPSTREAM OF CARBONATOR AS PER SECTION 608.16.1 OF THE 2004 FLORIDA PLUMBING CODE. 11 EXISTING GREASE INTERCEPTOR SHOWN FOR REFERENCE. FIELD VERIFY LOCATION. 12 EXISTING ICE MACHINE TO BE REMOVED. FIELD VERIFY EXACT LOCATION. DISPOSE OF AS PER YUM CONSTRUCTION MANAGER'S DIRECTION. CAP EXISTING FILTERED WATER LINES ABOVE CEILING OR AT WALL. 13 EXISTING 3" HUB DRAIN AT DEMO-6 ICE MACHINE. IF HUB DRAIN ONLY RECEIVES INDIRECT WASTE FROM ICE MACHINE, CONTRACTOR SHALL REMOVE AND DISPOSE OF AS YUM CONSTRUCTION MANAGER'S DIRECTION. REMOVE EXISTING WASTE PIPING BACK TO POINT OF CONNECTION AND CAP. PATCH FLOOR BACK TO LIKE -NEW CONDITION. VERIFY IN FIELD. CD NEW "HANDS FREE" HANDSINK TO REPLACE EXISTING HANDSINK. CONNECT TO EXISTING WATER SUPPLY, SANITARY AND VENT LINES. REFER TO PLUMBING NOTES #4, #5, AND DETAIL B/P2.0 FOR ADDITIONAL INFORMATION. 15 NEW "HANDS FREE" HANDSINK. REFER TO PLUMBING NOTES #4, #5, AND DETAIL B/P2.0 FOR ADDITIONAL INFORMATION. (aD PROVIDE NEW 1/2" HOT & COLD WATER PIPING SUPPLY FOR NEW HAND SINK AND CONNECT TO EXISTING. REFER TO WATER RISER F/P1.0 FOR INFORMATION. 17 PROVIDE 1-1/2" SANITARY FOR NEW HAND SINK AND CONNECT TO EXISTING. FIELD VERIFY SIZE, LOCATION, AND DIRECTION OF FLOW. REFER TO SANITARY RISER G/P1.0 FOR INFORMATION. KEY NOTES I C LEGEND EX/ST/NG NEW WORK ® NEW TO £X/S77NG CONNEC77ON PLUMBING PLAN 1/4"=V-0" CONNECT 1-1/4" GAS PIPING TO EXISTING GAS METER SUPPLYING AN ADDITIONAL 160 MBH AT 8" WATER COLUMN WITH AN ALLOWABLE PRESSURE DROP OF 0.5" W.C. NEW GAS METER BY LOCAL UTILITY COMPANY IF REQUIRED. CONTRACTOR SHALL VERIFY WITH LOCAL GAS UTILITY COMPANY THAT THE GAS GAS METER AND SERVICE LINE IS CAPABLE OF HANDLING THE ADDITIONAL LOAD. ONLY IN SEISMIC AREAS: INSTALL AN APPROVED SEISMIC SHUT-OFF VALVE ON SERVICE IF EXISTING VALVE IS NOT PRESENT. �2 EXISTING ELECTRICAL EQUIPMENT. NO PIPING SHALL CROSS THIS SPACE. INSTALL 1-1/4" MECHANICAL SOLENOID VALVE SUPPLIED BY OWNER DROP GAS PIPING THROUGH CEILING. LOCATE SOLENOID VALVE AND GAS COCK ADJACENT TO NEW GAS HOOD. ROUTE GAS PIPING UP IN CEILING SPACE, THEN DOWN IN WALL. INSTALL QUICK DISCONNECT AT FRYER. ® (REUSE EXISTING MIXING VALVE IF ONE IS PRESENT) PROVIDE THERMOSTATIC MIXING VALVE, LEONARD MODEL: 210 MOUNTED BELOW FIXTURE. SET TEMPERATURE AS REQUIRED BY AHJ. PIPE WATER FROM MIXING VALVE TO FOOT CONTROL (PROVIDED BY OWNER) THEN BACK TO HANDSINK. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS. INSTALL NEW MIXING VALVE IF REQUIRED BY LOCAL AUTHORITIES. 50 INSTALL HAND FREE MODEL: FOOT CONTROL PEDALS (SUPPLIED BY OWNER). CONNECT NEW 1/2 HOT AND COLD WATER TO EXISTTNG. VERIFY SIZES AND LOCATIONS OF EXISTING PLUMBING PRIOR TO INSTALLATION. PROVIDE FLEXIBLE STAINLESS STEEL -BRAIDED SUPPLY LINE TO FOOT CONTROL. SEE FOOT CONTROL DETAIL ON SHEET P-2. PROVIDE 0.5 GPM FLOW CONTROL IN OUTLET OF FAUCET. REPLACE PLUMBING FOUND IN POOR CONDITION. INSTALL PER MANUFACTURER'S REQUIREMENTS. PLUMBING NOTES: I B CONTRACT DATE: 03.21.08 BUILDING TYPE: ?WM. STORE NUMBER: 95343 ARCV NUMBER: 080406 6548 GALL BLVD. ZEPHYRHILLS, FL 33542 PLUMBING PLAN Pi so PLOT DATE: 02.19.08 N QUICK DISCONNECT GAS SHUTOFF VALVE, (2) 90' STREET ELBOWS, GAS HOSE, SWIVEL CONNECTIONS AND RESTRAINING DEVICES SHALL BE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR IF SWIVEL CONNECTION IS NOT RECEIVED WITH REST OF EQUIPMENT — ADVISE YUM CONSTRUCTION MANAGER. PLUMBING CONTRACTOR SHALL INSTALL GAS PIPING AS CLOSE AS POSSIBLE TO THE WALL. FRYERS SHALL BE INSTALLED FLUSH TO THE BACK OF HOOD, SPACE SHOWN IS FOR DRAWING CLARITY. IF WING FLOW/EQUIPMENT IS OPPOSITE AS THE PLANS IJ SHOWS, THE GAS LINE & ANSUL BOX SHALL SWITCH SIDES. 3' FLEX HOSE W/ SWIVEL & QUICK DISCONNECT DORMONT /16100BPOSR.36 PROVIDED BY OWNER GAS MANIFOLD SEE PLANS FOR SIZE 900 STREET ELBOW PIPE FITTING —TYPICAL — ONE STUB PER APPLANCE GAS UNE DOWN ON WHEN ALLOWED BY AW, IF NOT ALLOWED, PIPE GAS IN WALL AND LOCATE APPROVED VALVE OUTSIDE OF WALL - APPROVED VALVE IN RISE STREET ELBOW PIPE FITTING 6" DIRT LEG WALL TERMIM7E SLEEVE FLUSH WITH FINISHED WALL SURFACES SEAL OR CAULK SLEEVES THRU FIRE WALLS IN SMOKE TIGHT MANNER AND TO MEET FIRE RATING OF WALL (REFER TO ASTW E-814)-----_ PIPE AND INSULATION TO BE CENTERED IN SLEEVE — DO SUPPORT PIPE FROM SLEEVE MECHANICAL GAS SHUT—OFF VALVE LINKED TO ANSUL SYSTEM ----n ANSUL SYSTEM ME (7) 1 ROUTE GAS UNE ON FACE OF WALL WHEN ALLOWED BY LOCAL CODE — GAS 6" DIRT LEG TYPICAL TO GAS MAIN SEE PLANS FOR kZE LJ FRYER 1111 / _o_ i SEE PLANS FOR SIZES QUIK DISCONNECT FOR FLEXIBLE HOSE CONNECTION (TYPICAL). FRYER GAS CONNECTION DETAILS N.T.S. D STANDARD WEIGHT STEEL PIPE h SLEEVE OF SIZE TO PASS PIPE AND INSULATION. PLUS GAP AS REQUIRED BY LOCAL CODES. ALSO25 GACCEPTABSPLITL� SLEEVE FINISHED ESCUTCHEON PLATE FLUSH AGAINST WALL AND OF SIZE TO COMPLETELY COVER OPENING RN/SHED WALL SURFACE I CONCEALED PIPING PIPING EXPOSED TO VIEW NOTE PROVIDE FOR ALL MASONRY WALLS AND FIRE RATED WALLS PIPE SLEEVE INTERIOR WALLS N.T.S. I F THE EQUIPMENT ROUGH —IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE AND SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER, OWNER AND/OR TH£ EQUIPMENT ROUGH —IN DRAWINGS IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN ON THE PLAN. THEREFORE, THE ARCHITECT/ENGINEER SHALL BE IMMEDIATEL Y NOTIFIED, PRIOR TO CONSTRUCTION OF ANY DEVIATIONS FROM WHAT IS SHOWN OR IMPLIED ON THESE DRAWINGS. FAILURE OF THE APPROPRLATE CONTRACTOR TO VERIFY ROUGH —INS OR THEIR LOCATIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR ADDITIONAL ROUGH —INS DIRECTLY UPON THE CONTRACTOR. SYMBOL-S P L U M B I N G SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SANITARY DRAIN ABOVEGROUND 4— GAS COCK DO WC WATER CLOSET (TAW TYPE) �-- SANITARY DRAIN BELOWGROUND oi­ GLOBE VALVE VC WATER CLOSET (FLUSH VALVE) VENT LINE —IV— CHECK VALVE S STORM DRAIN ABOVEGROUND PRESSURE RELIEF VALVE UR URINAL =S= STORM BRAIN BELOWGROUND —pro-- STOP AND WASTE VALVE LAV LAVATORY -- COLD WATER (CV) STOP AND WASTE VALVE (IN RISE) ---- HOT WATER (HW) —y« MIXING VALVE ® KS KITCHEN SINK ---- HOT WATER CIRCULATING (HWC) PRESSURE REGULATING VALVE (PRV) SS SERVICE SINK G GAS LINE UNION Ih HE H13SE BIBB DF DRINKING FOUNTAIN —- STRAINER HWH WALL HYDRANT EVC ELECTRIC WATER COOLER BALANCING COCK Iq FH FIRE HYDRANT - Ef—�— RUNNING TRAP O NH MANHOLE COLUMN NUMBER CLEAN OUT +® VALVE IN RISE a O- PLUMBING RISER NUMBER —O GRADE CLEAN OUT QD -1 DRAIN AND MARK N.LTZ. NOT IN THIS CONTRACT ORD RAF DRAIN VTR VENT THROUGH ROOF ODS DOWN SPOUT VACUUM BREAKER V.C.P. VITRIFIED CLAY PIPE —�� BALL VALVE C.I. CAST IRON I.E. INVERT ELEVATION PROWL VALVE SET TE LOCAL CONCE COVER 1/2' STEE FUFA DUAL PED HANDSINK 1/2 ROLL VAL VE 1/2 12 (7YPICUL ) E MIXING WHEN REQUIRED 1/2 UPERATURE PER ® REQUIREMENTS 4L IN PEDESTAL 1/2 1/2 STAINLESS t—BRAIDED PEG ISLE LINES FOOT L ao ,—WALL HANDSINK TEMPERED ,R TO HAND SYMBOLS LEGEND I A HW & C Tj W —PROVIDE MIXING VALVE WHEN ' CW REQUIRED ESTAL COVER —STROP LINES TO WALL, FLEXIBLE LINES SHALL NOT TOUCH FLOOR. 90 DEGREE DUAL FOOT PEDAL 1 /4" X 3- TAPCON HEX HEAD SCREW TYPICAL. FOOT CONTROL DETAIL N.T.S. I B MAXIMUM SPACING FOR GAS PIPE SUPPORTS STUL PIPE SEE (NPS) SPA= N FEET YN. ROD SEE — INICHM (HORIZONTAL.) 1/2' 5' 3/8' 3/4' TO 1 1/4' 6' 3/8' 1 1/2' TO 3' 10, 1/2' (VMI-) 3 1/2- TO 5' EVERY FLOOR NOTE PAINT BLOCK & PLATE SAME AS SPECIFIED FOR OTHER SUPPORTS & PIPE ON ROOF. SPACING SAME AS SPEC/PIED FOR PIPE HANGERS. PIPE ROLLER TYPE PIPE PROVIDE 114 " PLATED LAG SCREWS SUPPORT 4" X 4" X 24" 7R6A7E9 ATTACH TO ROOF AS DIRECTED WOOD BLOCK BY THE ROOFING CONTRACTOR%F 1--ROOF -- /NSULAT/ON 04.24.08 HAND SINK ADDITION CONTRACT DATE: 03.21.08 BUILDING TYPE: ?????? STORE NUMBER: 95343 ARCV NUMBER: 080406 6548 GALL BLVD. ZEPHYRHILLS, FL 33542 P200 ROOFTOP PIPING SUPPORT N.T.S. C PLOT DATE: 02A9.08 p 2 A u 17 THE DEDICATED POS POWER CIRCUIT REQUIRES AN ISOLATED GROUND IN ADDITION TO THE NORMAL COMMON BUILDING GROUND. THE ISOLATED GROUND WIRE SERVES TWO PURPOSES: * AS A SAFETY PATH TO GROUND. * AS A ZERO REFERENCE POINT FOR ALL POS DIGITAL LOGIC. THE GROUND MUST EXHIBIT THE LOWEST POSSIBLE IMPEDANCE TO MINIMIZE VOLTAGE TRANSIENTS AND NOISE. NOTES: 1. USE AN INSULATED GREEN WITH YELLOW STRIPE CONDUCTOR FOR THE ISOLATED GROUND WIRE. 2. RUN THE ISOLATED GROUND WIRE THROUGH THE SAME CONDUIT AS THE HOT AND NEUTRAL WIRES. 3. INSTALL ONLY ISOLATED GROUND (IG) TYPE RECEPTACLES. 4. CONNECT THE ISOLATED GROUND WIRE TO BUILDING GROUND ONLY AT THE MAIN SERVICE PANEL DO MU CONNECT THE ISOLATED GROUND WIRE TO THE CONDUIT, JUNCTION BOXES, THE FRAME ON A SUBPANEL, OR ANY OTHER METAL SURFACE. DEDICATED CIRCUITS: DEDICATED CIRCUITS REQUIRE A DEDICATED HOT AND A NEUTRAL THAT ARE NOT SHARED WITH ANY OTHER CIRCUITS. SELECT THE CORRECT DETAIL THAT APPLIES TO THE PROJECT: none imn �1��1LM�1��1iL� �ATdbTdbTdbTdbTsTdbwal r► G "K3K3 PANEL UTILITY NEUTRAL EARTH GROUND ISOLATED GROUND SYSTEM N.T.S. ISOLATED GROUND IG EQUIPMENT GROUND EQUIPMENT GROUND IG RECEPTACLE DEDICATED HOT F SUBPANEL (OR EQUIPMENT SERVICE PANEL) ISOLATED GROUND SYSTEM N.T.S. CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE AND SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER, OWNER AND/OR THE EQUIPMENT ROUGH —IN DRAWINGS. IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN ON THE PLAN. THEREFORE THE ARCHITECT/ENGINEER SHALL BE IMMEDIATELY NOTIFIED, PRIOR TO CONSTRUCTION OF ANY DEVIATIONS FROM WHAT IS SHOWN OR IMPLIED ON THESE DRAWINGS. FAILURE OF THE APPROPRIATE CONTRACTOR TO VERIFY ROUGH —INS OR THEIR LOCATIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR ADDITIONAL ROUGH —INS DIRECTLY UPON THE CONTRACTOR. !�j MAIN SERVICE PANEL SUBPANEL) UTILITY NEUTRAL EARTH GROUND POLE WITH OL DEVICE SHALL BE CONNECTED TO 120V POWER FOR EX FAN MOTOR. - PANEL 20 AMP 2 POLE - CIRCUIT - BREAKER a �70 . 7 , 0 . r 1 - -• 71 r SQUARE D RE4 SERIES CAT# RE4RM11BU r R L---J I , FACTORY PROVIDED JUNCTION BOX, LOCATED ON PLAN (EXISTING) EF (TYPICAL) T SQUARE D CFSLA S 2510 PROVIDE 20 AMP DOUBLE POLE MANUAL STARTER SWITCH, LOCATED NEXT TO HOOD. (DISCONNECTING MEANS NOTE: FOR HOOD) NEUTRAL AND GROUND WIRE NOT SHOWN. FACTORY PROVIDED GLOBE LIGHTS (EXISTING) -FRYER (CONTROL PANEL) RTU-2 EVAPORATOR FAN CONTROL SEE DETAIL 6 ON THIS SHEET RTU-1 EVAPORATOR FAN CONTROL SEE \ DETAIL 6 ON THIS SHEET `— MICRO SWITCH LOCATED IN HOOD FIRE SUPPRESSION SYSTEM CONTROL PANEL PROVIDE 20 AMP DOUBLE POLE SWITCH IN NEMA 3R ENCLOSURE, LOCATED ON ROOF. (DISCONNECTING MEANS FOR EF-1) EXHAUST FAN/FRYER CONTROL DIAGRAM N.T.S. ��tl;Lt THERMOSTAT EXISTING sWUL ROOF TOP UNIT tm OFF EAT 1 VV1 HEAT 1 EAT t2 YY2 HEAT 2 (WHERE APPUCAE d FAN TO RTU INTERLOCK RELAY. DETAIL 2 ON THIS SHEET COOL 1 COOL 2 (WHERE APPLICABLE 24V CNTRL POWER LTO RTU INTERLOCK RELAY, DETAIL 2 ON THIS SHEET RTU FAN INTERLOCK NTS GENERAL DEMOLITION NOTES: A. REMOVE EXISTING ELECTRICAL AND TELECOMMUNICATION SYSTEMS COMPLETE FROM BUILDING WHERE INDICATED. ELECTRICAL CONTRACTOR TO FIELD VERIFY EXACT REQUIREMENTS AT THE PRE -BID WALK THROUGH AS SPECIFIED. B. UNLESS NOTED OTHERWISE, REMOVE ALL EXISTING ELECTRICAL AND TELECOMMUNICATION EQUIPMENT COMPLETE FROM BUILDING WHERE INDICATED. DO NOT ABANDON CONDUIT, WIRE, OR ANY ELECTRICAL EQUIPMENT/DEVICE IN PLACE. REMOVE ALL CONDUIT, BOXES, DEVICES, WIRING, PANELS, CABINET, ETC, COMPLETE FROM PREMISES. C. MATERIALS AND EQUIPMENT TO BE SALVAGED, WILL BE TAGGED BY THE OWNER PRIOR TO THE PRE -BID WALK THROUGH. REMOVE AND DELIVER MATERIALS AND EQUIPMENT TO BE SALVAGED TO THE STORAGE LOCATION DESIGNATED BY THE OWNER. D. REPORT FINDING OF ANY MATERIAL CONTAINING ASBESTOS IMMEDIATELY TO THE OWNER'S CONSTRUCTION REPRESENTATIVE. E. MATERIALS AND EQUIPMENT INDICATED TO BE REMOVED AND NOT SALVAGED, SHALL BECOME THE PROPERTY OF THE CONTRACTOR. THE CONTRACTOR SHALL REMOVE, TRANSPORT, AND LEGALLY DISPOSE OF THE DEMOLISHED MATERIAL, EQUIPMENT DEBRIS, AND RUBBISH OFF THE SITE. F. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE A MINIMUM OF (72) HOURS IN ADVANCE OF INTERRUPTING ANY UTILITIES OR BUILDING SERVICES, AND BEFORE SHUTTING DOWN ANY SYSTEMS OR EQUIPMENT. G. LIGHTING DEMOLITION - FLUORESCENT BALLAST AND LAMPS SHALL BE REMOVED AND DISPOSED OF SEPARATELY FROM CONSTRUCTION DEBRIS. PROPER PROTECTIVE EQUIPMENT MUST BE USED WHEN HANDLING LEAKING PCB BALLAST. CONTRACTOR SHALL PROVIDE STEEL DRUMS. CONTRACTOR SHALL SEPARATE PCB BALLASTS FROM NON PCB BALLASTS. AND PUT IN DRUMS. E.C. SHALL TAKE RESPONSIBILITY FOR PROPER DISPOSAL OF PCB CONTAINING BALLASTS. CLEAN LIGHT FIXTURE METAL OF ANY DEPOSITS LEAKED FROM BALLASTS, AND DISPOSE OF RAGS WITH BALLASTS. SPILLS MUST BE CLEANED UP IN ACCORDANCE WITH THE NATIONAL PCB CLEAN UP POLICY (52 FR 10688) FLUORESCENT LAMPS SHALL BE CONSIDERED HAZARDOUS WASTE CONTAINING MERCURY, LEAD, AND CADMIUM. CONTRACTOR SHALL OBTAIN SERVICES AND PROVIDE PROPER PACKAGING AND SHIPPING OF LAMPS FOR DISPOSAL DISPOSAL TO MEET ALL FEDERAL AND STATE REQUIREMENTS. ALL WASTE SHALL BE LABELED, STORED, HANDLED, TRANSPORTED, AND DISPOSED OF IN ACCORDANCE TO APPLICABLE STATE AND FEDERAL REGULATIONS. H. E.0 TO PROVIDE CONDUIT AND WIRE AS REQUIRED TO MAINTAIN ALL EXISTING BRANCH CIRCUITS AND DISTRIBUTION FEEDERS. THAT REQUIRE RELOCATION DUE TO WALL, FLOOR, OR CEILING DEMOLITION. E.C. TO REROUTE FEEDERS WHERE REQUIRED TO BYPASS ANY SUCH DEMOLITION. FIELD VERIFY EXACT REQUIREMENTS WITH ARCHITECTURAL AND ELECTRICAL DEMOLITION DRAWINGS PRIOR TO BID DATE. I. CONTRACTOR SHALL RELOCATE EXISTING LIGHTING FIXTURES AS NEEDED, DUE TO THE NEW FRYER HOOD LOCATION. GENERAL ELECTRICAL NOTES: A. THE WORK INCLUDES PROVIDING NEW MATERIALS, FIXTURES, DEVICES AND ACCESSORIES NECESSARY FOR A COMPLETE FUNCTIONING ELECTRICAL SYSTEM. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES OR ORDINANCES AND SUBJECT TO INSPECTION. B. COMPLY WITH ALL LAWS APPLYING TO ELECTRICAL INSTALLATIONS IN EFFECT, AND WITH THE MOST RECENT EDITION OF THE NATIONAL ELECTRICAL CODE, ADA, APPLICABLE SECTIONS OF OTHER NFPA, OSHA, LIFE SAFETY CODES AND RECOMMENDATIONS, AND THE INTERIM AMENDMENTS IN EFFECT AT THE TIME OF THE PROPOSAL ALL MATERIALS USED SHALL BE NEW AND SHALL CONFORM TO THE STANDARDS ESTABLISHED BY THE UNDERWRITERS LABORATORIES INCORPORATED. C. THE INTENT OF THE DRAWINGS IS TO INDICATE THE GENERAL EXTENT OF WORK REQUIRED FOR THE PROJECT. THE DRAWINGS FOR ELECTRICAL WORK ARE DIAGRAMMATIC. SHOWING THE LOCATION, TYPE, DEVICES AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. PROVIDE ALL FIXTURES, DEVICES, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY TO FACILITATE THE SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT FURNISHED BY OTHERS. D. EXISTING CONDITIONS ARE BASED ON "AS -BUILT" DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. CONTRACTOR IS TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. E. ELECTRICAL CONTRACTOR TO FIELD VERIFY ALL EXISTING UNDERGROUND UTILITIES. ANY ITEM DAMAGED BY THIS CONTRACTOR SHALL BE REPAIRED IMMEDIATELY AND AT NO COST TO THE OWNER. F. CONTRACTOR TO VERIFY PLACEMENT OF ALL DEVICES SHOWN ON THE ELECTRICAL CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL, MECHANICAL, PLUMBING, & KITCHEN DRAWINGS PRIOR TO FINAL PLACEMENT. G. ROOF PENETRATIONS SHALL COMPLY WITH "SMACNA7 AND 'NRCA" STANDARDS. AND WITH THE REQUIREMENTS OF THE EXISTING ROOFING WARRANTY. ALL PENETRATIONS SHALL BE COORDINATED WITH THE ROOFING CONTRACTOR. H. ELECTRICAL DESIGN HAS BEEN BASED ON THE INSTALLATION OF 75'C CONDUCTORS CONNECTED TO TERMINAL LUGS AND EQUIPMENT, U.L. LISTED FOR A MINIMUM 75'C. CONDUCTORS TERMINATED ON EQUIPMENT OR DEVICES WITH A LOWER RATING (60'C) OR NO RATING SHOWN, SHALL HAVE CONDUCTOR SIZE INCREASED TO CONFORM TO NEC TABLE 310-16 AND U.L NO. 489 REQUIREMENTS. I, CONDUIT SHALL BE SIZED TO COMPLY WITH NEC FOR NUMBER AND SIZE OF CONDUCTORS INSTALLED, MINIMUM 240 BELOW GRADE. PROVIDE SCHEDULE 40 PVC PLASTIC OR RIGID STEEL CONDUIT BELOW GRADE, MINIMUM 3/4-. PROVIDE ELECTRICAL METAL TUBING (EMT) MEETING FS W-0563, OR FLEXIBLE CONDUIT (IN LENGTHS 6' OR LESS) FOR INTERIOR LOCATIONS. EMT CONNECTORS AND COUPLING SHALL BE SET -SCREW TYPE. CLAMP CONDUIT TO BOXES WITH BUSHING INSIDE AND LOCKNUT OUTSIDE. J. ALL CONDUIT AND RACEWAY SYSTEMS SHALL BE INSTALLED WITH SEPARATE GROUND CONDUCTOR. CONDUIT SYSTEM IS NOT TO BE USED AS THE SOLE GROUNDING MEANS. K. CONTRACTOR MAY COMBINE CIRCUIT IN RACEWAYS, BUT IF MORE THAN (3) CURRENT CARRYING CONDUCTORS ARE INSTALLED THEN CONTRACTOR TO DERATE CONDUCTORS IN ACCORDANCE WITH N.E.0 TABLE 310-15(bX2)(a). L E.C. SHALL PROVIDE AND INSTALL ELECTRICAL DEVICES AND WIRING TO COMPLY WITH N.F.PA. 96.7-3.1.3 FOR POWER SHUTOFF ON HOOD FAN AND ALL ELECTRICAL EQUIPMENT UNDER OVEN HOOD WHERE REQUIRED BY LOCAL CODE. VERIFY INSTALLATION AND OPERATION REQUIREMENTS WITH EXTINGUISHING SYSTEM SUPPLIER WHEN PRESENT. M. FOR EQUIPMENT FURNISHED BY OWNER OR OTHER CONTRACTORS; ELECTRICAL CONTRACTOR SHALL VERIFY EXACT LOAD, TYPE OF CONNECTION AND MOUNTING HEIGHT FOR EACH BOX OR EQUIPMENT ITEM TO BE INSTALLED. ALL HARD -WIRED CONNECTIONS TO EQUIPMENT SHALL BE MADE WITH FLEXIBLE LIQUID -TIGHT METAL CONDUIT WITH GREEN GROUND CONDUCTOR INSTALLED INSIDE RACEWAY. GROUND CONDUCTOR SHALL BE BONDED AT BOTH ENDS. N. PULL AND JUNCTION BOXES SHALL BE 16 GAUGE, OR HEAVIER, STEEL, WITH REMOVABLE KNOCKOUTS. BOXES SHALL BE AS MANUFACTURED BY APPLETON, STEEL CITY OR RACO. SIZE BOXES AS REQUIRED FOR THE INTENDED DUTY, MINIMUM SIZE AS REQUIRED BY THE NATIONAL ELECTRICAL CODE. 0. RECEPTACLES SHALL BE LOCATED AS SHOWN ON THE DRAWINGS AND AT THE HEIGHTS SPECIFIED OR INDICATED. RECEPTACLE AND POWER OUTLETS SHALL BE SPECIFICATION GRADE, 20 AMP, GROUNDING TYPE AS MANUFACTURED BY HUBBELL, GENERAL ELECTRIC, PASS & SEYMOUR, EAGLE, OR LEVITON. RECEPTACLES SHALL BE WHITE. COLOR OF DEDICATED RECEPTACLES SHALL BE RED. P. ALL RECEPTACLES AND DATA/TELEPHONE OUTLETS SHALL BE MOUNTED AT +170 TO CENTER OF BOX UNLESS OTHERWISE NOTED. Q. REFER TO ARCHITECTURAL DRAWING FOR EQUIPMENT SCHEDULE. FIELD VERIFY ALL KITCHEN EQUIPMENT ELECTRICAL DATA WITH THE FOOD SERVICE CONTRACTOR. VERIFY EXACT LOADS, MOUNTING HEIGHTS AND NEMA CONFIGURATIONS PRIOR TO ROUGH -IN. R. SEE SHEET E-2 FOR LIGHT FIXTURE SCHEDULE. S. COORDINATE WITH THE SIGN CONTRACTOR AND ARCHITECT FOR NEW SIGN WATTAGE, VOLTAGE, AND EXACT LOCATION PRIOR TO J-BOX INSTALLATION. Q 04.24.08 HAND SINK ADDITION CONTRACT DATE: 03.21.08 BUILDING TYPE: ?????? STORE NUMBER: 95343 ARCV NUMBER: 080406 6548 GALL BLVD. ZEPHYRHILLS, FL 33542 El m0 PLOT DATE: 02.19.08 T, ■ P r 1. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO SUBMITTING HIS BID TO INVESTIGATE ACTUAL EXISTING CONDITIONS, AND CIRCUIT AVAILABILITY IN EXISTING PANEL BOARD. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES, 2, ALL KITCHEN 15 AND 20 AMP RECEPTACLES SHALL BE GFI TYPE. 3. ALL ELECTRICAL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE N.E.C. AND LOCAL CODES. SHEET GENERAL NOTES N.T.S. 1 3 1 1O PROVIDE A 4" OCTAGONAL BOX FOR ANSUL FIRE SUPPRESSION SYSTEM PULL STATION. VERIFY EXACT LOCATION OF JUNCTION BOX WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH -IN INSTALLATION, EXTEND A 1/2" EMPTY CONDUIT UP TO ACCESSIBLE CEILING. SEE SHEET M2.0, CONNECT TO EXISTING FIRE SUPPRESSION SYSTEM CIRCUIT. O PROVIDE A 2"x4" J-BOX W/DOUBLE RJ-45 DATA JACKS. PROVIDE A SINGLE GANG MUD RING AND COVER PLATE AS REQUIRED. PROVIDE 1" CONDUIT, WITH PULL STRING TO ABOVE ACCESSIBLE CEILING. O NOT USED, O PROVIDE 120V, 1 P/20 AMP GFI RECEPTACLE FOR FRYER 18" A.F.F. PROVIDE 120V, 1 P/20 AMP CIRCUIT BREAKER WITH SHUNT TRIP IN EXISTING PANEL "B". O PROVIDE 120V, 1 P/20 AMP DUPLEX RECEPTACLE. SEE DETAIL #2 SHEET E1.0. O PROVIDE 120V, 1 P/20 AMP ISOLATED GROUND TYPE RECEPTACLE @ 36" A.F.F. FOR PRINTER AND 84" FOR MONITOR. CONNECT TO EXISTING MONITOR CIRCUIT. O NOT USED. O PROVIDE 120V, 1 P/30 AMP NEMA-3R DISCONNECT ON ROOF FOR EXHAUST FAN. SEE DETAIL #2 SHEET E1.0, PROVIDE 2P/20 AMP CIRCUIT BREAKER WITH SHUNT TRIP IN EXISTING PANEL "B". VERIFY EXACT LOCATION OF FAN. O PROVIDE (3)#12 AND (1)#12 GROUND IN 1/2" CONDUIT. 10 PROVIDE (2)#12 AND (1)#12 GROUND IN 1/2" CONDUIT, 11 SEE DETAIL #2 ON SHEET E1.0 FOR EXHAUST FAN/FRYER CONTROL DIAGRAM. (�D MAKE CONNECTION TO LIGHTS IN HOOD FURNISHED WITH HOOD. 13 HOOD FIRE SUPPRESSION CONTROL PANEL (ELECTRICAL SWITCHES) PROVIDED BY OTHERS, SEE ELEVATION ON SHEET M2.0 FOR EXACT LOCATION, (�D PROVIDE 120V, 1 P/20 AMP RECEPTACLE, CONNECT TO EXISTING PANEL "B". 15 ELECTRICAL CONTRACTOR SHALL RECIRCUIT EXISTING COOLER AND FREEZER LIGHTS FROM CIRCUIT B-38 TO B-36. 16 PROVIDE FLUSH MOUNTED CEILING RECEPTACLE AND J-BOX OUTLET FOR NEW TV'S (3 - LOCATIONS). CONNECT TO 120V CIRCUIT IN PANEL "B". J-BOX IS FOR CABLE T.V. IF REQUIRED BY LOCAL CODE. 17 E.C. TO EXTEND & REUSE EXISTING DEMOED ICE CONDENSER CIRCUIT TO LOCATION OF NEW ROOF -TOP ICE MACHINE CONDENSER. VERIFY AND MAKE FINAL CONNECTIONS. (2D E.C. TO REUSE EXISTING DRINK DISPENSER CIRCUIT & OUTLET FOR NEW DRINK DISPENSER/ICE MAKER. SHEET KEYED NOTES N.T.S. 1 2 1 CEILING LINE EXISTING 300 AMP SERVICE FEEDER. BUILDING WALL, LEASE LINE. I I t fEXISTING (4)#350KC MIL AND (1)#3 GROUND IN 3" CNDT. CEILING LINE EXISTING =, t - EXISTING E EXISTING EXISTING CT/METER = PANEL "B" ;PANEL 'A" _ PANEL "C" 120/208V 120/208V 120/208V 30,4W E 30,4W ? I 30AW 120/208V 300 AMP E 200 AMP I 200 AMP 30,4W I M.C.B. I € 400 AMP E N0 WORK i NO WORK t I ---A-EXISTING (4)#1/0 AND (1)#6 t GROUND IN 2" CNDT. EXISTING GROUND. FINISH GRADE LINE EXTERIOR INTERIOR FINISH FLOOR LINE ONE LINE DIAGRAM 1/4"=1'-0" 1 5 1 04.24.08 HAND SINK ADDITION CONTRACT DATE: 03.21.08 BUILDING TYPE: ?????? STORE NUMBER: 95343 ARCV NUMBER: 080406 6548 GALL BLVD. ZEPHYRHILLS, FL 33542 ELECTRICAL FLOOR PLAN E2,0 ELECTRICAL FLOOR PLAN 1/4"=1'-0" '� PLOT DATE: 02.19.08 �y col -I ZIA I rS