Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6816 Gall Blvd (3)
NTERI &"T A9 agmsmhl OVATIO 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 DENNIS COLWELL ow 'ARCHITECTS 132 CENTRAL STREET, SUITE 203, FOXBOROUGH, MA 02035 P. 508-241-2122 F. 508-455-4466 WWW.DC-ARCHITECT.COM REVIEW D CITYOF ZEPH---aS8U/LDING L�� pFFIC1qL All. ES FL sHN!_L, Ct?Iv;RLy WITH PREVAILING NATIONAL EOLEC 7"RICt INt; ooe ORDINANCES CODE, AND THE CITY OF zEI�HyRM1«.s ALL NFFAWORKSHALL AND STANDARDS REVIEW DATE CITY OF ZEPHYRHILLS FIRE AND LIFE SAFETY EXAMIN 4, O_F_F(O h VAC0LbVF�('9 A 99449 N d' cy) M J H J J CL W N ry W J O In i� 141) i U L.0 O h AT EQ EQUAL MAT. MATERIAL SHEET NUMBER e DRAWING NAME DATE ISSUED REVISION COVER SHEET PROJECT: PINCHASERS ANTHONY PERRONE ZL ANGLE EXI. / EXIST. EXISTING CENTERLINE EXH EXHAUST L CHANNEL EXP. EXPOSED PERPENDICULAR EXT. EXTERIOR > PLATE F.B.C. FURNISHED BY CONTRACTOR ROUND/ DIAMETER ' F.B.O. FURNISHED BY OWNER A.F.F. ABOVE FINISH FLOOR F.C. FIRE CODE MAX. MAXIMUM MECH MECHANICAL MEP -FP MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION MET, METAL MEZZ. MEZZANINE MFR MANUFACTURER GENERAL CONSTRUCTION NOTES: 1. GENERAL CONTRACTOR SHALL INSPECT THE SITE AND SHALL BE FAMILIAR WITH ALL CONDITIONS AND WITH LIMITATION OF THE CONTRACT AND SCOPE OF WORK. 2. ALL CONTRACTORS SHALL ENSURE THAT ALL WORK AND MATERIALS SHALL COMPLY WITH ALL FIRE SAFETY, HEALTH, LOCAL AND STATE BUILDING CODES. UNLESS OTHERWISE AGREED TO IN WRITING, CONTRACTOR S SHALL BE RESPONSIBLE TO SECURE ALL PERMITS AND PAY FEES FOR THE SAME AS REQUIRED BY STATE AND LOCAL RULES AND REGULATIONS. CS COVER SHEET GENERAL G1.0 IGENERAL NOTES AND WALL TYPES G1.1 CODE ANALYSIS PLAN DEMOLITION Dl .0 FIRST FLOOR DEMOLITION PLAN A.P. ACCESS PANEL A.T. ASPHALT TILE A/C AIR CONDITIONING A.C.T. ACOUSTICAL CEILING AC. ACRE ADD'N ADDITION ADD. ADDENDUM UST. ADJUSTABLE ADJUST. ALT. ALTERNATE ALUM. ALUMINUM ANCHOR(AGE) ANCH. ANCHOR ANOD. ANODIZED APPROX. APPROXIMATE ARCH. ARCHITECTURAL) ASPH. ASPHHLT B.M. BENCHMARK B.W. BOTH WAYS B.O. BOTTOM OF BD. BD. BOARD BLDG. BUILDING BLKG. BLOCKING BLKT. BLANKET BM. BEAM BRG. BEARING BRK. BRICK F.D. F.E. F.E.C. TILE F.H. F.O. F.P. FDN. FLR. FIN. FIXT. FL. F.O.F. F.O.S. ' F.O.W. FR. FRM'G. FT. FTG. FUR, FURN. F.R.P. F.R.P.T. F.R. FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HYDRANT FRAME OPENING FIREPROOFING FOUNDATION FLOOR FINISHED) FIXTURE FLOOR FACE OF FOUNDATION FACE OF STUD FACE OF WALL FRAME FRAMING FEET FOOTING FURRING FURNITURE FIBERGLASS REINFORCED PANEL FIRE RETARDANT PRESSURE TREATED FIRE RATED MIN MISC. MLDG. M.O. M.R. MTL MULL. N.A. N.I.C. NOM N.T.S. NAT. NO. NOM. O.A. O.C. O.D. OPNG. OPH OPP P&M P.M.S. PBD, PERM. P,C. MINIMUM MISCELLANEOUS MOULDING MASONRY OPENING MOISTURE RESISTANT METAL MULLION NOT APPLICABLE A NOT A CONTRACT NOMINAL NOT TO SCALE NATURAL NUMBER NOMINAL OVERALL ON CENTER OUTSIDE DIAMETER OPENING OPPOSITE HAND OPPOSITE PATCH & MATCH PREFORMED METAL SIDING PARTICLE BOARD PERIMETER PRE CAST 3. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS BEFORE PROCEEDING WITH WORK. 4. ANY ERRORS, AMBIGUITIES, DISCREPANCIES, OR OMISSIONS IN DRAWINGS OR NOTES SHALL BE REPORTED TO THE ARCHITECT FOR CORRECTION OR CLARIFICATION BEFORE ANY PART OF THE WORK IS STARTED. 5. IN GENERAL, ALL BUILDING SURFACES WITHIN CONSTRUCTION LIMITS SHALL BE CLEANED AT PROJECT COMPLETION, USE CLEANING MATERIALS AS RECOMMENDED BY PRODUCT MANUFACTURERS. EMPLOY EXPERIENCED WORKMEN OR PROFESSIONAL CLEANERS. BEFORE INSPECTION FOR SUBSTANTIAL COMPLETION, COMPLETE ALL NECESSARY CLEANING WITHIN AREA OF WORK, INCLUDING THE FOLLOWING: REMOVE GREASE, DIRT, STAINS, FINGERPRINTS, ETC. FROM EXPOSED TO VIEW FINISHED SURFACES. TOUCH UP MARRED SURFACES AS REQUIRED, REMOVE PROTECTIVE COVERS FROM, CLEAN AND POLISH EXPOSED TO VIEW FIXTURES, WINDOWS, HARDWARE, ETC. 6, ALL FINISH MATERIAL SHALL BE STORED SO IT IS CLEAN AND FREE FROM STAIN OR DISCOLORATION. 7. THE CONTRACTOR SHALL SUBMIT REQUIRED SHOP DRAWINGS, FINISH AND OR COLOR SAMPLES AND EQUIPMENT CUTS PRIOR TO INSTALLATION TO THE ARCHITECT AND OWNER FOR APPROVAL BEFORE CONSTRUCTION BEGINS. IF NOT SPECIFIED OTHERWISE, COLORS AND FINISHES OF SPECIFIED PRODUCTS WILL BE SELECTED FROM MANUFACTURER'S STANDARD RANGE. SHOP DRAWINGS, PRODUCT DATA, AND OTHER SUBMITTALS (OTHER THAN ACTUAL SAMPLES) SHALL BE SUBMITTED IN ELECTRONIC (PDF) FORMAT WHEREVER POSSIBLE. IF PAPER SUBMITTALS ARE SUBMITTED, PROVIDE ONE (1) COPY FOR REVIEW. 8. THE ACCEPTANCE OF THE CONTRACT CARRIES WITH IT A GUARANTEE ON THE PART OF THE CONTRACTOR TO MAKE GOOD ANY DEFECTS IN WORK AND WORKMANSHIP FOR ONE YEAR FROM COMPLETION OF THE ENTIRE 9. GENERAL CONTRACTOR SHALL CARRY ALL INSURANCE, SATISFACTORY TO OWNER. 10. DO NOT SCALE DRAWINGS TO DETERMINE LOCATIONS AND LAYOUT OF THE WORK. 11. BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE WORK PREMISES WHILE JOB IS IN PROGRESS AND UNTIL JOB IS COMPLETED. 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 -- - PROJECT NUMBER: 21161 - - - - -- ARCHITECTURAL A1.0 FIRST FLOOR PLAN A]. 1 EQUIPMENT AND FURNITURE PLAN A2.1 REFLECTED CEILING PLAN A7.1 DOOR SCHEDULE A7.2 ROOM SCHEDULE A8.1 INTERIOR ELEVATIONS . A$2 INTERIOR ELEVATIONS AND PLAN DETAILS A8.3 INTERIOR DETAILS �, V) �, J w L p U N � CD U Q w � I- - 2 = U Q Q O m PLUMBING P0.1 PLUMBING -LEGENDS &SYMBOLS Pl .0 PLUMBING - NEW WORK PLAN WATER WASTE & VENT P2.0 PLUMBING -SPECIFICATIONS FIRE PROTECTION FPI.I FIRE PROTECTION FP1.2 FIRE PROTECTION MECHANICAL M0.1 MECHANICAL - LEGENDS & SYMBOLS Ml .0 MECHANICAL -NEW WORK PLAN M2.0 MECHANICAL -SCHEDULES M3.0 MECHANICAL -SPECIFICATIONS BVL. BVL CABT. CARP. C.I. C.I.P. C.G. C.J. CL. C.L.L. C.M.P. CLR BASEMENT BEVELED CABINET CARPENTER CAST IRON CAST -IN -PLACE CORNER GUARD CONTROL JOINT CLOSET CONTRACT LIMIT LINE CORRUGATED METAL CEILING CLEAR GA GALV G.C. GL GWB GYP. BD. H. HDWR H.C. PIPE H.M. H/C HBD. GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GYPSUM WALL BOARD GYPSUM BOARD HEIGHT HARDWARE HOLLOW CORE HOLLOW METAL HANDICAPPED HARDBOARD PLWD PLYWOOD PLAM PLASTIC LAMINATE PLAS. PLASTER PLBG. PLUMBING P.T. PRESSURE TREATED PTD PAINTED PLYWD. PLYWOOD PNL. PANEL PR. PAIR PREFAB. PREFABRICATE(D) Q.T. QUARRY TILE QTY. QUANTITY RAD/ R RADIUS 12. THE OWNER RESERVES THE RIGHT TO PERFORM ADDITIONAL WORK THAT IS NOT PART OF THE CONTRACT WITH HIS OWN FORCES, UNDER SEPARATE CONTRACTS AND/ OR WITH OTHER CONTRACTORS OR VENDORS. COOPERATE WITH THE OWNER AND THE OTHER CONTRACTORS AND COORDINATE WORK WITH THE OWNER SO THAT WORK BY OTHERS CAN BE INCORPORATED IN A TIMELY MANNER . 13. ALL DAMAGES TO THE BUILDING PROPERTY DUE TO CONTRACT OPERATIONS MUST BE REPORTED IMMEDIATELY TO THE OWNER'S REPRESENTATIVE. 14. ALL MATERIALS SHALL BE FURNISHED AND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTRUCTIONS AND RECOMMENDATIONS, BY SKILLED WORKMEN UNDER ADEQUATE SUPERVISION. MATERIALS AND METHODS OF INSTALLATION SHALL ALSO CONFORM TO THE APPROPRIATE NATIONAL TRADE HANDBOOKS; I.E. ARCHITECTURAL WOODWORK INSTITUTE's QUALITY STANDARDS, UNITED STATES GYPSUM'S, GYPSUM CONSTRUCTION HANDBOOK, ETC. COPIES OF MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR ALL PRODUCTS SHALL BE AVAILABLE AT JOB SITE. 15. ALL MILLWORK, WOODWORK AND WOOD DOORS SHALL BE FABRICATED, FURNISHED, AND INSTALLED IN STRICT ACCORDANCE WITH THE APPROPRIATE SECTIONS OF THE ARCHITECTURAL WOODWORK INSTITUTES, ARCHITECTURAL WOODWORK QUALITY STANDARDS', CUSTOM GRADE, UNLESS OTHERWISE NOTED. PROVIDE ARCHITECTURAL WOODWORK INSTITUTE QUALITY CERTIFICATION PROGRAM LABELS OR CERTIFICATES INDICATING THAT THE WOODWORK, INCLUDING INSTALLATION, COMPLIES WITH REQUIREMENTS OF GRADES SPECIFIED. O u T 1 .......ILI��� ZCLG o .o CD �O p N � w Lo H-Lo N pp p w V) w � (- MD1.0 MECHANICAL - DEMOLITION ELECTRICAL E0.1 ELECTRICAL -LEGENDS &SYMBOLS E1.0 ELECTRICAL - LIGHTING PLAN E1.1 ELECTRICAL - POWER PLAN El .2 ELECTRICAL - LIFE SAFETY PLAN E2.0 ELECTRICAL - SCHEDULES E3.0 ELECTRICAL - DETAILS E4.0 ELECTRICAL -SPECIFICATIONS ED1.0 ELECTRICAL - DEMOLITION COMB. COMP. CMU COL CONC CONT COMBINATION HDWD. COMPOSITE HDWR. CONCRETE MASONRY UNIT HD COLUMN HORIZ. CONCRETE HR. CONTINUOUS HVAC HARDWOOD HARDWARE HIGH POINT HORIZONTAL HOUR HEATING, VENTILATION, REINF. REF. REF. RET. R.D. RO REINFORCING REFERENCE REQUIRED RETURN ROOF DRAIN ROUGH OPENING 16. ANY SUBSTITUTIONS FOR MATERIALS/MANUFACTURERS SYSTEMS SPECIFIED MUST BE PREAPPROVED BY THE ARCHITECT. SUBMIT SUBSTITUTION REQUEST IN WRITING, ALONG WITH APPROPRIATE SHOP DRAWINGS, PROPOSED MANUFACTURER'S PRODUCT DATA, AND SAMPLE(S) OF PRODUCT(S) IN COLOR COLORS)/FINISH(ES) PROPOSED. NOTE THE REASON FOR THE SUBSTITUTION AND ANY COST SAVINGS TO BE CREDITED TO THE OWNER FOR USE OF SUBSTITUTED PRODUCT OR SYSTEM. EVALUATION OF CONTRACTOR -PROPOSED SUBSTITUTIONS BY THE ARCHITECT MAY REQUIRE ADDITIONAL SERVICES IN THE FORM OF RESEARCH OR REDESIGN. THE OWNER AND/OR CONTRACTOR WILL BE NOTIFIED OF THE NEED FOR ADDITIONAL SERVICES PRIOR TO REVIEW OF A PROPOSED SUBSTITUTION. THE OWNER MUST AUTHORIZE ADDITIONAL SERVICES PRIOR TO THE ARCHITECT CONDUCTING A REVIEW OF THE PROPOSED SUBSTITUTION IN QUESTION. r W I Q � I N N z v. w N U ao DRAWING LIST CPT. C.T. D. CARPET CERAMIC TILE DEPTH I.B.C. LB.O. AIR CONDITIONING INSTALLED BY CONTRACTOR INSTALLED BY OWNER REV. RM. SIM REVISED/ REVISION ROOM SIMILAR 17. SUBSTITUTIONS: WHEN PROVIDING A PRODUCT OR MATERIAL WHICH IS A SUBSTITUTE FROM WHAT THE DRAWINGS SHOW AS THE "BASE SPECIFICATION", THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ANY VARIATIONS FROM THE ORIGINALLY SPECIFIED PRODUCT, INCLUDING BUT NOT LIMITED TO DIMENSIONAL VARIATIONS, UTILITY REQUIREMENTS, OR STRUCTURAL SUPPORT. I CN O M '- o- D.F. D.H. D.O. DEFL. DIA DIAG. DIMEN. DRINKING FOUNTAIN DOUBLE HUNG DOOR OPENING DEFLECTION DIAMETER DIAGONAL DIMENSION I.C.S. I.D. IMPREG. INCL. INSUL INT. INV. INSULATED COMPOSITE SIDING INSIDE DIAMETER IMPREGNATED INCLUDE(D) (-ING) INSULATE(D) (-[ON) (-ING) INTERIOR INVERT SP SQ S.C. S.S. STL STD TEMP SPACES SQUARE SOLID CORE STAINLESS STEEL STEEL STANDARD TEMPERED 18. ARRANGE AND PAY FOR ANY REQUIRED TEMPORARY UTILITIES AND FACILITIES. PROVIDE TEMPORARY HEAT AND WEATHER PROTECTION AS REQUIRED. 19. LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREIN OR NOT AND PROTECT THEM FROM DAMAGE. BEAR ALL EXPENSE OR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH PERFORMANCE OF THE WORK. 20. LOCATIONS FOR CONSTRUCTION DUMPSTERS OR OTHER TEMPORARY FACILITIES AND STAGING AREAS OUTSIDE OF THE WORK AREA MUST BE REVIEWED BY THE OWNER'S REPRESENTATIVE. (1) LAYER OF 5/8" GYP. BD. ON EACH SIDE 3 5/8" 25 GA. STEEL STUDS @ � 16" O.C. � DL DN. DN. DWG DR D.S. EA EJ EP EIFS ELEC. ELEV E ESTITIM. DEAD LOAD DOWN DETAIL DRAWING DOOR DOWNSPOUT EACH EXPANSION JOINT ELECTRIC PANEL EXTERIOR INSULATION FINISH SYSTEM ELECTRICAL ELEVATION ENCLOSURE ESTIMATE J.C. JT L. LAM. LAV. LF LG. LG. LT -GA. LTL. LVR. LL L.P. MACH. JANITOR CLOSET JOINT LENGTH LAMINATED LAVATORY LINEAR FEET LONG LOCATE(D) (-ION) LIGHT GAUGE LINTEL LOUVER LIVE LOAD LOW POINT MACHINE T&G T T.O.S.. U.N.O. VERT. VEST. VCT WD. W.C. W.R. W.P. W/O W/ WDW. TONGUE & GROOVE TOP OF STEEL TYPICAL UNLESS NOTED OTHERWISE VERTICAL VESTIBULE VINYL COMPOSITION TILE WIDTH WOOD WATER CLOSET WATER RESISTANT WATERPROOF WITHOUT WITH WINDOW 21 •NEW GYPSUM WALLBOARD SUBSTRATES APPLIED OVER NEW STEEL STUDS OR NEW WOOD STUDS SHALL BE SECURED WITH APPROPRIATE SCREW FASTENERS. INSTALLATION SHALL BE IN ACCORDANCE WITH "GYPSUM CONSTRUCTION HANDBOOK" BY USG. ALL JOINTS SHALL BE TAPED AND FINISHED AND APPROPRIATE METAL TRIM PROVIDED WHERE REQUIRED. 22. PROVIDE BACK -BLOCKING AS REQUIRED TO ACHIEVE FIRM ATTACHMENT OF ALL ITEMS Of ARCHITECTURAL WOODWORK, AND ALL OTHER WALL AND/OR CEILING MOUNTED FINISHES, EQUIPEMNT, AND ACCESSORIES, FIXTURES, ETC. 23. PROVIDE A BEAD OF SANITARY, MILDEW RESISTANT SILICONE SEALANT AT THE FOLLOWING LOCATIONS: METAL DOOR FRAME AND WALL CONSTRUCTION. CONDUIT AND PIPE PENETRATIONS AT WALLS AND CEILINGS. JUNCTION OF MILLWORK AND SURROUNDING SURFACES. TOILET ACCESSORIES. BASEBOARD TO WALL. WINDOW FRAMES AND MISC.TRIMWORK JOINTS WITH WALLS, ELSEWHERE AS SHOWN ON DRAWINGS OR WHERE REQUIRED BY THE ARCHITECT, OR LOCAL AUTHORITIES. PROVIDE PAINTABLE SEALANTS AT LOCATIONS SCHEDULED TO RECEIVE PAINTED OR STAINED FINISHES. 24. DESIGNATE DELIVERY DATES OF OWNER FURNISHED ITEMS IN THE CONSTRUCTION SCHEDULE, RECEIVE, UNLOAD, AND HANDLE OWNER FURNISHED ITEMS TO BE INSTALLED BY THE CONTRACTOR AT THE SITE. STORE MATERIALS DELIVERED TO THE SITE OFF GROUND, UNDER COVER, IN DRY WELL VENTILATED LOCATIONS SECURE FROM VANDALISM AND THEFT. IN FULL CONFORMANCE WITH MANUFACTURER'S RECOMMENDATIONS. CAREFULLY PROTECT 3 1/2" SOUND ATTENUATION BATTS NOTE: EXTEND STUDS TO UNDERSIDE OF DECK/STRUCTURE, EXTEND GYP. BD. AND INSULATION TO b" ABOVE CEILING. A NON -RATED WALL 3 1/2" SOUND ATTENUATION BATTS ABBREVIATIONS STORED MATERIALS FROM DAMAGE, DAMPNESS, AND EXTREMES OF TEMPERATURES. PROVIDE SEPARATIONS BETWEEN FINISHED MATERIALS WHICH ARE STORED IN STACKED OR LEANING POSITIONS. 25. CLOSE-OUT SUBMITTALS REQUIRED AT FINAL COMPLETION SHALL INCLUDE: OPERATING AND MAINTENANCE MANUALS. INSTRUCTION OF OWNER AND/OR BUILDING OWNER PERSONNEL IN MAINTENANCE AND OPERATION OF SYSTEMS. 3 5/8" 25 GA. STEEL 16" O.C. STUDS @ 4 A8.1 2 MATCHLINE INTERIOR ELEVATION KEY. INDICATED NUMBERS USED FOR VIEW IDENTIFICATION I Mom NEW STUD WALL NEW CMU WALL SUBMISSION OF CERTIFICATIONS, TEST REPORTS, ETC. PROVISION OF SPARE PARTS AND MAINTENANCE MATERIALS, NEATLY WRAPPED OR PACKAGED IN STANDARD SIZES, AND CLEARLY LABELED. THIS INCLUDES EXTRA STOCK OF CARPET, VINYL TILE, AND PAINT OF EACH COLOR AND SHEEN SPECIFIED. CERTIFICATE OF INSURANCE FOR PRODUCTS AND COMPLETED OPERATIONS. TYPED LIST OF MAJOR SUB -CONTRACTORS AND SUPPLIERS WITH ADDRESSES AND TELEPHONE NUMBERS. 26. PLAN AND SCHEDULE WORK AND PURCHASING IN ORDER TO MINIMIZE ON -SITE CONSTRUCTION TIME AND DISRUPTION OF EXISTING BUILDING OCCUPANTS AND OPERATIONS. (1) LAYER OF 5/8" GYP. BD. ON EACH SIDE NOTE: EXTEND STUDS TO UNDERSIDE OF DECK/STRUCTURE. EXTEND GYP. BD. AND 27. THE OWNER MAY AUTHORIZE THE CONTRACTOR TO COMMENCE WORK BASED ON THE CONTRACTOR'S AGREEMENT TO ADHERE TO CERTAIN RULES AND REGULATIONS. THE CONTRACTOR SHALL AGREE TO ANY SUCH RULES INSULATION TO 6" ABOVE CEILING. NEW BRICK WALL AND REGULATIONS TO THE SATISFACTION OF THE OWNER PRIOR TO START OF WORK. A COPY OF CURRENT RULES, IF AVAILABLE SHALL BE PROVIDED BY THE OWNER AT CONTRACTOR'S REQUEST. A5.1 EXTERIOR ELEVATION KEY. NUMBERS USED FOR VIEW IDENTIFICATION EXISTING WALL TO BE REMOVED 28. THE OWNER RESERVES THE RIGHT TO INSTALL EQUIPMENT IN COMPLETED AREAS OF THE BUILDING, PRIOR TO SUBSTANTIAL COMPLETION PROVIDED THAT SUCH OCCUPANCY DOES NOT INTERFERE WITH COMPLETION OF THE WORK. NON - RATED WALL B 29. MAINTAIN MEANS OF EGRESS DURING CONSTRUCTION AS REQUIRED BY NFPA 101, LIFE SAFETY CODE, CURRENT EDITION AND LOCAL AUTHORITIES. 1 REVISION TAG EXISTING WALL TO REMAIN 30. WORKMEN SHALL CONDUCT THEMSELVES IN A REASONABLE MANNER (I.E. SHALL NOT USE PROFANITY, CREATE A NUISANCE TO SURROUNDING BUILDING OCCUPANTS, LOITER IN SURROUNDING BUILDINGS, ETC.). 31. IN THE EVENT THAT ANY PORTION OF THE WORK WILL DISTURB AND/OR DISRUPT ANY OTHER OPERATIONS IN THE BUILDING, MAKE ARRANGEMENTS WITH THE OWNER TO CONDUCT THE WORK AT A TIME AGREED UPON BY THE AFFECTED OPERATIONS AND/OR PARTIES. ANY AND ALL SUCH WORK AND RELATED CIRCUMSTANCES SUCH AS POWER SHUT DOWNS, PIPING, CABLING, FIRE ALARM, ETC., WILL BE COORDINATED WITH ALL AFFECTED WALLS LEGEND OWINDOW AA TAG OPERATIONS, OWNER AND AUTHORITIES HAVING JURISDICTION OVER THE AFFECTED WORK. cl WALL TYPE; SEE WALL TYPES ON DWG. G 1.0 - SPOT ELEVATION - CEILING HEIGHT EARTH STAMP: DEMOLITION KEYNOTE ❑p DRAWING KEYNOTE - .- °a .� _ �a GRAVEL e OF -FL O,Q� 4bP 9 ' • I � � if "' '�i I • 1 SIM A6.1 1 SIM 1 SIM DETAIL VIEW KEY ° a CONCRETE CMU A 444 I ,' �� ' BRED ARCS PARTITION TYPES SCALE: 1 1/2" = 1'-0" A6.1 A6.1 FULL BUILDING SECTION KEY ALL DIMENSIONS SHOWN ARE SHOWN AS FOLLOWS: FRAMED CONSTRUCTION 1 SIM WALL AND PARTIAL SECTION KEY BRICK WALLS: FACE OF STUD TO FACE OF STUD DOORS / WINDOWS: CENTERLINE OF UNIT ALL ANGLE'S ARE 45 ^ OR 90 ^ UNLESS NOTED OTHERWISE ISSUE: DATE: ISSUED FOR PERMIT Ol .25.2023 A6.1 MASONRY/ CONCRETE CONSTRUCTION ROOM NAME 101 ROOM TAG BATT INSULATION 1. PROVIDE CEMENT BACKER BOARD IN LIEU OF GYP. BOARD AT ALL LOCATIONS SCHEDULED TO WALLS: FACE OF MASONRY TO FACE OF MASONRY DOORS / WINDOWS: MASONRY OPENING RECEIVE CERAMIC TILE. SEE INTERIOR ELEVATIONS AND ROOM FINISH SCHEDULE. FINISHED DIMENSIONS SHALL BE NOTED AS EITHER FINISHED OR CLEAR ON DIMENSION STRING. 101A DOOR TAG; SEE DOOR SCHEDULE RIGID INSULATION 2. PROVIDE MOISTURE RESISTANT GYP. BOARD IN LIEU OF REGULAR GYP. BOARD AT ALL WET WALL AREAS (RESTROOMS, KITCHENS, SERVICE AREAS, ETC.) SEE INTERIOR ELEVATIONS AND ROOM FINISH DIMENSIONING NOTES ON DWG. A7.?? SCHEDULE. N 3, ALL JOINTS OF GYPSUM BOARD/CEMENT BACKER BOARD SHALL BE TAPED AND FINISHED PER MANUFACTURER'S WRITTEN SPECIFICATIONS. PROVIDE ALL APPROPRIATE TRIM AND ACCESSORIES FOR NORTH ARROW STEEL A COMPLETE INSTALLATION. 4. PRIME PAINT AND OTHERWISE PREPARE WALL SUBSTRATES IN ACCORDANCE WITH MANUFACTURER'S (NOTES ARE NOT KEYED ON DRAWINGS) G.1 ALL CONSTRUCTION IS TO COMPLY WITH ANY AND ALL APPLICABLE LOCAL DRAWING SCALE: As indicated SPECIFICATIONS, AND AS REQUIRED TO RECEIVE FINISHES SPECIFIED. AND STATE BUILDING CODES. A O SIM A4.1 FINISH TAG; SEE FINISH SCHEDULE ON DWG. g7.22 ENLARGED PLAN OR DETAIL CALLOUT ROUGH LUMBER 5. INSTALL GYPSUM BOARD FINISH ON UNRATED WALLS TO 6" ABOVE CEILING, TYP., UNLESS NOTED OTHERWISE ON WALL TYPES. REVIEW ALL DRAWINGS FOR FINISHES, MILLWORK, FIXTURES AND EQUIPMENT ITEMS THAT WILL REQUIRE BACK -BLOCKING IN WALLS TO PROPERLY ATTACH SAME. COORDINATE WORK SO THAT ALL BACK -BLOCKING IS PROVIDED PRIOR TO INSTALLATION OF SUBSTRATES ON PARTITIONS. G.2 EACH PRIME SUBCONTRACTOR IS RESPONSIBLE FOR OBTAINING AND PAYING FOR REQUIRED PERMITS AND SCHEDULING REQUIRED INSPECTIONS UNLESS DIRECTED OTHERWISE BY OWNER. G.3 GENERAL CONTRACTOR SHALL ERECT TEMPORARY BARRIERS, WARNING SIGNS, CONSTRUCTION FENCING ETC. TO MAINTAIN A SAFE WORKING ENVIRONMENT. DRAWN BY: CHECKED BY: Checker DRAWING TITLE:6. GENERAL NOTES AND WALL TYPES PLYWOOD 7. METAL STUD FRAMING AT INTERIOR DOOR JAMBS AND WINDOW SHALL BE 20 GA., TYP. GA CONSTRUCTION DEBRIS AND DEMOLISHED MATERIALS SHALL BE DISPOSED ALIGN SURFACES FINISHED WOOD 8. ISOLATE FRAMING SYSTEM FROM STRUCTURAL LOADING BOTH HORIZONTALLY AND VERTICALLY. 9. PROVIDE SLIP OR CUSHIONED JOINTS AT TOP OF WALLS WHERE THEY MEET STRUCTURAL BEAMS OR DECK ABOVE. MAINTAIN LATERAL STABILITY. OF IN A LAWFUL AND TIMELY MANOR. G.5 CONTRACTOR SHALL PROTECT ALL REQUIRED MEANS OF EGRESS THROUGHOUT ENTIRE CONSTRUCTION PERIOD. SHEET NUMBER: 10. DEPTH: 3-5/8" STUDS UNLESS OTHERWISE NOTED, OR REQUIRED TO MEET SPAN AND DEFLECTION CONSTRAINTS. G.6 CONTRACTOR SHALL BE RESPONSIBLE FOR THE BRACING AND SHORING OF THE STRUCTURE THROUGH OUT THE ENTIRE CONSTRUCTION PERIOD. ARCHITECTURAL PLAN SYMBOLS MATERIALS LEGEND GENERAL CONSTRUCTION NOTES GENE11 RAL INTERIOR WALL NOTES PERMITTING & LOCAL REQUIRMENTS • LIFE SAFETY PLAN LIFE SAFETY PLAN LEGEND 1 /8" = 1'-0" HD 135 RATE OF RISE HEAT DETECTOR �O CARBON MONOXIDE DETECTOR EXIT SIGN FD 200 FIXED HEAT DETECTOR H S FIRE ANNUNCIATOR (HORN/STROBE) S FIRE ANNUNCIATOR (MINI STROBE) PS PULL STATION D\) SMOKE DETECTOR (PHOTO ELECTRIC) \_i SO, SMOKE DETECTOR (IONIZING) KEY SAFE (KNOX BOX) FE FIRE EXTINGUISHER CABINET EGRESS PATH WALL MOUNTED EMERGENCY LIGHT FIXTURE v No I J �0' CODE SUMMARY PINCHASERS 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 AREA INCLUDED WITHIN SCOPE IS A RENOVATION OF 29,000 SF OF AN EXISTING ASSEMBLY A-2 (RESTAURANT) AND A-3 (BOWLING ALLEY AND AMUSEMENT ARCADES) IN A SINGLE STORY TYPE 2B BUILDING. 101.5 COMPLIANCE METHODS (CODES USED FOR ANALYSIS): 7T" EDITION OF THE FLORIDA BUILDING CODE: 2020 FLORIDA BUILDING CODE, BUILDING (2018 IBC) 2020 FLORIDA BUILDING CODE, EXISTING BULDING (2018 IEBC) 2020 FLORIDA BUILDING CODE, PLUMBING 2020 FLORIDA BUILDING CODE 301.1.3.2 WORK AREA COMPLIANCE METHOD ALTERATIONS, ADDITIONA AND CHANGES OF OCCUPANCY COMPLYING WITH THE APPLICABLE REQUIREMENTS OF CHAPTER 6 THROUGH 12 OF THIS CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISION OF THIS CODE. 2018- INTERNATIONAL EXISTING BUILDING CODE WITH FLORIDA AMENDMENTS CHPATER 6 - CLASSIFICATION OF WORK 603.1 - LEVEL 2 ALTERATIONS INCLUDE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, HE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. CHAPTER 7-8 - ALTERATIONS LEVEL 2 701.2 CONFORMANCE - AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE THAN IT'S EXISTING CONDITION. COMPLIES 702.1 (-) 702.3 BUILDING ELEMENTS AND MATERIALS -ALL NEW FINISHES SHALL COMPLY WITH CHAPTER 8 OF THE IBC - COMPLIES 704.1 MEANS OF EGRESS: ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF PROTECTION PROVIDED FOR THE MEANS OF EGRESS COMPLIES 801.3 - COMPLIANCE ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY I WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. - COMPLIES 803.2 - AUTOMATIC SPRINKLER SYSTEMS AUTOMATIC SPRINKLER SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH THE REQUIREMENTS OF SECTIONS 804.2.1 THROUGH 804.2.5. INSTALLATION REQUIREMENTS SHALL BE IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. IBC 903.2.1.2 SPRINKLER SYSTEM SUPERVISION & ALARMS AUTOMATIC SPRINKLER SYSTEM IS REQUIRED > 5,000 SF OR 100+ OCCUPANTS COMPLIES - SPRINKLER SYSTEM IS INSTALLED 803.4 FIRE ALARM AND DETECTION A FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH SECTIONS 804.4.1.1 THROUGH 804.4.1.7. EXISTING ALARM -NOTIFICATION APPLIANCES SHALL BE AUTOMATICALLY ACTIVATED THROUGHOUT THE BUILDING. WHERE THE BUILDING IS NOT EQUIPPED WITH A FIRE ALARM SYSTEM, ALARM -NOTIFICATION APPLIANCES WITHIN THE WORKAREA SHALL BE PROVIDED AND AUTOMATICALLY ACTIVATED. - COMPLIES 805.3.1 NUMBER OF EXITS EVERY STORY UTILIZED FOR HUMAN OCCUPANCY ON WHICH THERE IS A WORK AREA THAT INCLUDES EXITS OR CORRIDORS SHARED BY MORE THAN ONE TENANT WITHIN THE WORK AREA SHALL BE PROVIDED WITH THE MINIMUM NUMBER OF EXITS BASED ON THE OCCUPANCY AND THE OCCUPANT LOAD IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. IN ADDITION, THE EXITS SHALL COMPLY WITH SECTIONS 805.3.1.1 AND 805.3.1.2. - COMPLIES 805.3.3 MAIN ENTRANCE - GROUP A BUILDINGS OF GROUP A WITH AN OCCUPANT LOAD OF 300 OR MORE SHALL BE PROVIDED WITH A MAIN ENTRANCE CAPABLE OF SERVING AS THE MAIN EXIT WITH AN EGRESS CAPACITY OF NOT LESS THAN ONE-HALF OF THE TOTAL OCCUPANT LOAD. THE REMAINING EXITS SHALL BE CAPABLE OF PROVIDING ONE-HALF OF THE TOTAL REQUIRED EXIT CAPACITY. TOTAL OCCUPANTS :330; MAIN ENTRANCE - 69" = 13.8" 805.4.1.1 OCCUPANT LOAD AND TRAVEL DISTANCE IN ANY WORK AREA, ALL ROOMS AND SPACES HAVING AN OCCUPANT LOAD GREATER THAN 50 OR IN WHICH THE TRAVEL DISTANCE TO AN EXIT EXCEEDS 75 FEET (22 860 MM) SHALL HAVE A MINIMUM OF TWO EGRESS DOORWAYS. EXCEPTIONS: l . STORAGE ROOMS HAVING A MAXIMUM OCCUPANT LOAD OF 10. 2. WHERE THE WORK AREA IS SERVED BY A SINGLE EXIT IN ACCORDANCE WITH SECTION 805.3.1.1 . SEE LIFE SAFETY PLAN - COMPLIES 805.7.1 - MEANS OF EGRESS LIGHTING MEANS OF EGRESS IN ALL WORK AREAS SHALL BE PROVIDED WITH ARTIFICIAL LIGHTING IN ACCORDANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. - COMPLIES 805.8.1 - EXIT SIGNS WHERE THE WORK AREA ON ANY FLOOR EXCEEDS 50 PERCENT OF THAT FLOOR AREA, MEANS OF EGRESS THROUGHOUT THE FLOOR SHALL COMPLY WITH SECTION 805.8.1. - COMPLIES - SEE ELECT. DWGS. 2018 IBC WITH AMENDMENT 302.1 CLASSIFICATION USE GROUP: 303.1 A-2 -ASSEMBLY GROUP (ACCESSORY USE) TABLE 601 FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS CONSTRUCTION TYPE 2B PRIMARY STRUCTURAL FRAME: 0 HOUR BEARING WALLS EXTERIOR: 0 HOUR BEARING WALLS INTERIOR: 0 HOUR EXTERIOR NON -BEARING: 0 HOUR INTERIOR NON -BEARING: 0 HOUR ROOF CONSTRUCTION: 0 HOUR TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT GAMING FLOORS 11 GROSS SF PER OCCUPANT ASSEMBLY; UNCONCENTRATED 15 NET SF PER OCCUPANT ACCESSORY STORAGE 300 GROSS SF PER OCCUPANT COMMERCIAL KITCHEN 200 GROSS SF PER OCCUPANT MERCANTILE 60 GROSS SF PER OCCUPANT BOWLING CENTERS 5 PERSONS/ LANE AND 15' OF RUNWAY AND 7 NET SF PER OCCUPANT FOR ADD'L. ARCADE: 1,391 SF/ 11 = 126 OCCUPANTS BOWLING LANES: 32 LANES x 5 = 160 OCCUPANTS RESTAURANT; 937 SF/ 15= 63 OCCUPANTS COMMERCIAL KITCHEN & BAR: 855 SF/ 200 = 5 OCCUPANTS BAR SEATING: 25 SEATS MERCATILE (PRO SHOP) = 291 SF/ 60 = 5 OCCUPANTS STORAGE: 2,566 SF/ 300 = 9 OCCUPANTS TOTAL = 330 OCCUPANTS 1005.1 MINIMUM REQUIRED EGRESS WIDTH EGRESS COMPONENTS: 0.2 X 330 OCCUPANTS= 66" WIDTH TOTAL DOOR WIDTH - 129" PROVIDED COMPLIES TABLE 1006.2.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY EXTERIOR EXITS: 2 REQUIRED ACTUAL: 3 COMPLIES MAXIMUM COMMON PATH OF TRAVEL < 75' PROJECT: PINCHASERS ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 STAMP: r ^ L 12 i cO v J CD U CV C) u �, w LLJ D- 2 U U �J Ofo W m O X 0 1 c \�- 10 CN CN IT ^ Ln Ln v7 06 z Wo U w H � z c/7 CCN V LLJ � N Q Z � w CV U C6 CV CD C'7 Ln CL /100 alai' OF FLO'Qi G? MC0LWF�`'9 p AR 99449 V �SA . kA ISSUE: DATE: ISSUED FOR PERMIT 01.25.2023 DRAWING SCALE: As indicated DRAWN BY: CHECKED BY: Checker DRAWING TITLE: CODE ANALYSIS PLAN SHEET NUMBER: Glol I. KEYNOTES - DEMOLITION PLAN PROJECT: r — — — Ef — — — — — — — — — — — — — — — — — — ---- —---------- I ,) I II I 1 —1-------------------------, o07 L— — — — J — — — — — — — — — — — — — — — — — — — — — — - nni II I /_z f"" I I I 001 IF------ 1 I II IIF_ —_---_— I I II \ o01 �4 I I II L_� ►I -------- 003 I 8.1 DEMOLITION PLAN 1 /8" = 1'-0" 001 IN GENERAL, REMOVE ALL EXISTING FLOOR, WALL, AND CEILING TILE (GRID TO REMAIN) INCLUDING EXISTING LIGHTING. UNLESS NOTED OTHERWISE. 002 REMOVE EXISTING MILLWORK IN IT'S ENTIRETY 003 PROVIDE OPENING FOR NEW DOOR 004 EXISTING LOCKERS TO BE REMOVED AND DPOSED OF. 005 EXISTING MILLWORK, REMOVE EXISTING COUNTERTOPS AND SALVAGE FOR USE AS TEMPLATE FOR NEW COUNTERS. 006 EXISTING LIGHTING TO REMAIN. 007 REMOVE PORTION OF EXISTING CEILING TILES AND GRID FOR NEW CEILING. GENERAL DEMOLITION NOTES II 1. IN ACCORDANCE WITH FEDERAL REGULATIONS PROMULGATED UNDER THE CLEAN AIR ACT, AND COMMONLY REFERRED TO AS ASBESTOS NESHAP, MORE SPECIFICALLY, 40 CFR PART 61, SUBPART M, SECTION 61.145, THE CONTRACTOR SHALL VERIFY THAT AN ASBESTOS SURVEY HAS BEEN CONDUCTED PRIOR TO THE COMMENCEMENT OF DEMOLITION OR RENOVATION WORK WHICH IS PART OF THIS CONTRACT. 2. IN ACCORDANCE WITH ABOVE REGULATION REQUIREMENTS, THE CONTRACTOR SHALL FILE WRITTEN NOTIFICATION WITH THE EPA PRIOR TO ANY DEMOLITION WORK BEING PERFORMED REGARDLESS OF THE AMOUNT OF ASBESTOS, INCLUDING ZERO. 3. ALL DEMOLITION WORK SHALL BE PERFORMED IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS. SECURE REQUIRED PERMITS. ARRANGE WITH BUILDING OWNER AND/OR APPROPRIATE UTILITY COMPANIES FOR SERVICE SHUTOFFS BEFORE BEGINNING DEMOLITION OPERATIONS. 4. CONSULT WITH OWNER AND FIRE OFFICIALS PRIOR TO MAKING ANY ALTERATIONS TO THE EXISTING FIRE ALARM AND SPRINKLER SYSTEM. 5. COORDINATE ALL DEMOLITION OPERATIONS WITH OWNER FOR SHUTDOWN PERIODS AND SEQUENCE OF WORK. PROVIDE TEMPORARY DUST PARTITIONS, BARRICADES, SIGNAGE, AND PROTECTIVE ENCLOSURES REQUIRED TO PROPERLY SECURE, ISOLATE, WATERPROOF, AND PROTECT AREAS OF WORK FROM EXISTING AREAS TO REMAIN IN OPERATION AND TO ASSURE CONTINUING FACILITY OPERATIONS IN GENERAL. IDENTIFY AND PROTECT ANY AREAS WHERE DEMOLITION IS TO TAKE PLACE WHERE THE DEMOLITION CREATES A PHYSICAL SAFETY HAZARD. THE CONTRACTOR SHALL KEEP THE CORRIDORS AND EXITS CLEAR OF DEBRIS, STORED MATERIALS, ETC., AT ALL TIMES TO PROVIDE REQUIRED FIRE EGRESS FROM THE BUILDING. 6. MAKE EVERY EFFORT POSSIBLE TO MINIMIZE DISTURBANCES TO BUILDING OCCUPANTS. COORDINATE HOURS OF DISRUPTIVE DEMOLITION WITH BUILDING OWNER PRIOR TO COMMENCEMENT. 7. IT IS NOT THE INTENT TO SHOW EVERY PIECE OR ITEM TO BE REMOVED IN DEMOLITION WORK. MECHANICAL, ELECTRICAL AND OTHER WORK RELATED TO A WALL OR AREA SCHEDULED FOR DEMOLITION AND REMOVAL SHALL BE REMOVED WHETHER SPECIFICALLY ITEMIZED OR NOT. TERMINATE, CAP AND REMOVE ALL ABANDONED ELECTRICAL CONDUIT, WIRING BOXES, SWITCHES, ETC; PLUMBING, PIPING, AND PLUMBING FIXTURES, ETC; HVAC DUCTWORK, CONTROLS, PIPING, ETC; AS REQUIRED. 8. WHEN WALLS, COLUMNS, OR OTHER SUPPORTING AND/OR BRACING ELEMENTS ARE SCHEDULED FOR DEMOLITION, TEMPORARY STRUCTURAL SUPPORTS AND BRACING FOR THE ADJACENT CONSTRUCTION SHALL BE PROVIDED AND MAINTAINED UNTIL THE PERMANENT SUPPORTING STRUCTURES ARE IN PLACE AND ABLE TO SUPPORT IMPOSED LOADS. ANY STRUCTURAL BRACING DISCOVERED DURING DEMOLITION IS NOT TO BE REMOVED - NOTIFY ARCHITECT OF ANY AND ALL SUCH DISCOVERIES IMMEDIATELY. 9. WHERE EXISTING WALL SUBSTRATES REMAIN AS BASE MATERIAL SURFACES FOR INSTALLATION OF NEW FINISHES, REMOVE PROJECTIONS, FILL VOIDS, SECURE OR REMOVE AND REPLACE ANY EXISTING LOOSE OR OTHERWISE UNSUITABLE SUBSTRATE MATERIALS AND ADD BLOCKING OR STRAPPING TO RECEIVE NEW MATERIALS AND FINISHES STRIP EXISTING WALL FINISH MATERIAL TO EXPOSE SUBSTRATE WHERE NEEDED. 10. REMOVE ALL FINISH FLOORING MATERIALS INCLUDING WALL BASE FROM EXISTING FLOORS SCHEDULED TO RECEIVE NEW FLOORING. GRIND, SCRAPE, SAND, CLEAN AND OTHERWISE PREPARE SUBSTRATE PRIOR TO INSTALLATION OF NEW FINISH FLOORING. PREPARE SUBSTRATE IN ACCORDANCE WITH FLOORING MANUFACTURER'S WRITTEN SPECIFICATIONS. PROVIDE LEVELING MASTICS AND GROUTS AS REQUIRED TO RENDER SUBSTRATES LEVEL AND TRUE TO 1 /8" IN 10', AND AS REQUIRED TO BLEND ADJACENT DISSIMILAR FLOORING MATERIALS. 11. REMOVE EXISTING CEILING FINISH MATERIAL, FRAMING/SUSPENSION SYSTEMS, INCLUDING LIGHT AND CEILING FIXTURES, AS REQUIRED TO ACCOMMODATE NEW WORK. IN ROOMS WHERE CEILINGS ARE TO REMAIN AND SECTIONS OF PARTITIONS ARE TO BE REMOVED/RELOCATED, CEILINGS SHALL BE PATCHED AND REPAIRED TO MATCH EXISTING. 12. NEATLY SAWCUT SLAB, AND TRENCH AND EXCAVATE FOR NEW PLUMBING OR ELECTRICAL WORK AS SHOWN OR REQUIRED ON PLUMBING AND ELECTRICAL DRAWINGS. WHERE CUT FOR TRENCHING, BACKFILL, COMPACT FILL REPAIR/INSTALL NEW VAPOR BARRIER TO PROVIDE WATER TIGHT SYSTEM, AND PATCH SLAB TO BLEND INDISTINGUISHABLE WITH ADJACENT SLAB. REPAIR EXISTING VAPOR BARRIER. 13. PATCH, REPAIR AND REFINISH ALL SURFACES TO MATCH AND ALIGN WITH EXISTING ADJACENT SURFACES SCHEDULED TO REMAIN, AND PREPARE TO RECEIVE NEW FINISHES SPECIFIED. WORK SHALL INCLUDE ALL LABOR AND MATERIALS ON ALL SURFACES REQUIRED TO RENDER SUBSTRATES ACCEPTABLE TO RECEIVE NEW FINISHES SPECIFIED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS. 14. PROTECT FROM LOSS OR DAMAGE ALL ITEMS INTENDED FOR SALVAGE AND REUSE, OR SCHEDULED TO REMAIN. 15. REPLACE IN KIND ANY EXISTING CONSTRUCTION, OR ITEM INTENDED TO REMAIN, OR BE SALVAGED FOR REUSE, BUT DAMAGED OR LOST AS A RESULT OF THE WORK OF THIS CONTRACT. 16. REUSE OF SALVAGED MATERIALS NOT SPECIFICALLY SCHEDULED FOR REUSE, WILL BE AT THE SOLE DISCRETION OF THE OWNER. IN NO CASE SHALL SALVAGED MATERIAL BE INCORPORATED IN THE WORK THAT DOES NOT MEET MINIMUM REQUIREMENTS OF STATE AND LOCAL CODES AND REGULATIONS. 17. SCHEDULES OF ADDITIONAL ITEMS TO BE SALVAGED (IF ANY) ARE TO BE PROVIDED BY THE OWNER UPON REQUEST OF THE CONTRACTOR. 18. ITEMS TO BE SALVAGED BUT NOT SO SCHEDULED ON THE DEMOLITION PLAN SHALL BE CONFIRMED BY THE CONTRACTOR WITH THE OWNER. ALL ITEMS TO BE TURNED OVER TO THE OWNER, SHALL BE PROTECTED DURING DEMOLITION AND REMOVAL AND SHALL BE DELIVERED IN AN UNDAMAGED CONDITION. 19. REMOVE ALL DEMOLISHED MATERIALS NOT SCHEDULED FOR SALVAGE AND REUSE, OR THOSE TO BECOME PROPERTY OF THE OWNER, FROM THE SITE AND DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS. 20. TAKE CARE TO DISCONNECT ALL ELECTRICAL POWER TO PARTITIONS AND OTHER ITEMS, AREAS, ELEMENTS INVOLVED IN THE DEMOLITION PRIOR TO DEMOLITION. 21. CONFINE TOOLS AND EQUIPMENT, STORAGE OF MATERIALS AND OPERATIONS TO LIMITS DESIGNATED BY THE BUILDING OWNER. THE PREMISES SHALL BE MAINTAINED IN SAFE, ORDERLY CONDITION AT ALL TIMES. REMOVE DEBRIS DAILY. COVER DUMPSTERS WITH FIRE RESISTANT TARPS SECURELY FASTENED TO PREVENT VANDALISM. 22. IN THE EVENT THAT SUSPECTED HAZARDOUS MATERIALS ARE DISCOVERED DURING THE COURSE OF DEMOLITION, CEASE WORK IMMEDIATELY AND NOTIFY THE BUILDING OWNER OF ANY SUCH DISCOVERIES. 23. FOR ADDITIONAL DEMOLITION NOTES, REFER TO STRUCTURAL, MECHANICAL AND ELECTRICAL DEMOLITION DRAWINGS, IF ANY. 24. DEMOLITION PLANS SHALL BE USED IN CONJUNCTION WITH DRAWINGS FOR NEW CONSTRUCTION (INTERIOR ELEVATIONS, DETAILS, ETC.) SO THAT EXACT LIMIT AND BOUNDARIES OF SPECIFIC DEMOLITION MAY BE DETERMINED. 25. ENSURE THAT ALL ELECTRICAL, MECHANICAL, FIRE PROTECTION, VOICE/DATA WIRING, AND PLUMBING SYSTEMS SERVING OTHER TENANTS AND BASE BUILDING SYSTEMS WILL REMAIN OPERATIONAL DURING THE COURSE OF DEMOLITION. SURVEY THE SITE BEFORE STARTING WORK TO IDENTIFY LOCATIONS OF THESE SYSTEMS, DEMOLITION FLOOR PLAN SYMBOLS EXISTING DOOR TO REMAIN R EXISTING DOOR TO BE DEMOLISHED I a EXISTING WALL TO REMAIN EXISTING WALL TO BE DEMOLISHED PINCHASERS ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 ('') O Mon0 U N O u JI IW <Lu = U �Q � W o� m O X oLL (D 10 lq- w r f�Lo �•/ ) ~ 00 z w O u F- LL z N N N LLJ N H Z Q w N U ' N O M Lo r CL STAMP: 09 M COL;V, 9 A 449� 7� ISSUE: ISSUED FOR PERMIT DRAWING SCALE: DRAWN BY: DATE: 01.25.2023 As indicated CHECKED BY: Checker DRAWING TITLE: FIRST FLOOR DEMOLITION PLAN SHEET NUMBER: DI 0 • - I - I. . 1, di.- , � • j iLOW. Jtia 10 KEYNOTES - FLOOR PLAN 101 ALIGN FINISHES 102 BUILT-IN MILLWORK; SEE REFERENCED ELEVATIONS/DETAIL, 103 COUNTER AND DISPLAY CASE; FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. 104 EXISTING MILLWORK TO BE REFINISHED; SEE REFERENCED ELEV 105 LOCKERS; FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. 106 WALK-IN COOLER; FURNISHED BY OWNER, INSTALLED BY CONTRACTOR 107 TV MONITOR; PROVIDE IN -WALL WD. BLOCKING. 108 PROVIDE 1/4" CEMENT BOAR, DUROCK OR EQUAL) OVER EXISTING/ NEW WALL CONSTRUCTION FOR THIN BRICK APPLICATION. 109 FUR -OUT WALL CONSTRUCTION W/ 3/4" MDF OVER 1X FURRING STRIPS. TO MATCH ADJACENT MILLWORK. Lo: 11 IE ROOM 1b2 FLOOR PLAN FLOOR PLAN SYMBOLS 1 /8" = 1'-0" � EXISTING DOOR TO REMAIN NEW DOOR; SEE DOOR SCHEDULE ON DWG. A7.?? EXISTING WALL TO REMAIN y NEW WALL CONSTRUCTION; SEE WALL TYPES ON DWG. G1.0 PROJECT: PINCHASERS ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 STAMP: CY) O p U CV CD u < w --� W U" (Dw �Q 0 �u m ,§ o Q� LL_ �10 10 u C) 04 uj VI ~ V) 06 Z wCD U Lu� z CV / �{ C- W 0 Z� w CV U' N O M Lo a _4 ' A 449 ISSUE: DATE: ISSUED FOR PERMIT 01.25.2023 DRAWING SCALE: 1 /8" = 1 '-0" DRAWN BY: CHECKED BY: Checker DRAWING TITLE: FIRST FLOOR PLAN SHEET NUMBER: Al .0 1-UKNI I UKE ANU LUUlFMLN I FLAN 1'-01, PROJECT: PINCHASERS ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 r^ m0 C U N O u J � U � Lu LLJ = U ry 06 LL U10 N r ^ Lu �J �/ JLn ~ ul) z w0 w U. LL ~ z N c/.) N W � �N 0 z� w< u 06 N N O C") Ln r CL- z� STAMP: OF_F40+, MCP , O g?�\�MCOLWF�C,9 • ; O� —tit — 1�,� • A 449 r RED AaG L� ISSUE: DATE: ISSUED FOR PERMIT 01.25.2023 DRAWING SCALE: 1 /8" = 1 0° DRAWN BY: CHECKED BY: Checker DRAWING TITLE: EQUIPMENT AND FURNITURE PLAN SHEET NUMBER: Al 0 l KEYNOTES - REFLECTED CEILING PLAN 201 GYP.BD. CEILING/ SOFFIT 202 EXISTING CEILING/ LIGHTING TO REMAIN AS -IS. 203 INSTALL NEW CEILING TILE @ EXISTING GRID.PROVIDE 24x48 ARMSTRONG CIRRUS SECOND LOOK (2X2) BEVELED TEGULAR 15/16 (ACT-1) 204 NEW CEILING TILE AND GRID;ARMSTRONG, KITCHEN ZONE, 2X2 CEILING TILE W/ SQUARE LAY -IN 15/16" GRID. (ACT-2) 205 ALIGN FINISHES 206 NEW GYP.BD. SOFFIT AND COVE LIGHT; SEE DETAIL ON A8.3. REMOVE EXITING CEILING TILE AND GRID AS REQUIRED FOR INSTALLATION. 207 EXISTING LIGHTING TO REMAIN; REINSTALL AS REQUIRED FOR INSTALLATION OF NEW CEILING TILES. GENERAL CEILING NOTES 1. THIS DRAWING IS INTENDED FOR FINISHES, FIXTURE LOCATIONS, AND COORDINATION. SEE ELECTRICAL DRAWINGS FOR COMPLETE SCHEDULE OF LIGHT FIXTURES, SEE MECHANICAL DRAWINGS FOR DIFFUSERS AND EQUIPMENT. 2. CEILING HEIGHTS ARE FROM FINISH FLOOR LEVEL. 3. SOFFIT FRAMING DIMENSIONS ARE FROM FACE OF WALL (F.O.W.) UNLESS OTHERWISE NOTED. 4. GRID DIMENSIONS ARE FROM FACE OF GYP. BD. 5. SUSPENDED CEILING GRID SHALL BE CENTERED IN BOTH DIRECTIONS OF A ROOM UNLESS OTHERWISE NOTED OR AS INDICATED BY WORKING POINTS AND/OR FULL TILE DESIGNATIONS. 6. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS TO DETERMINE THAT ALL PROPOSED CEILING HEIGHTS ARE ACHIEVABLE. NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK. 7. CENTER LIGHTS, SPRINKLER HEADS, AND OTHER DEVICES ON ACOUSTIC TILE UNLESS NOTED OTHERWISE. 8. DO NOT INSTALL MECHANICAL, ELECTRICAL, OR PLUMBING DEVICES REQUIRING ACCESS ABOVE GYPSUM BOARD CEILINGS UNLESS ACCESS PANELS ARE PROVIDED, IN ALL CASES, LOCATE SUCH DEVICES ABOVE ACCESSIBLE CEILINGS OR ACCESS PANELS. REFLECTED CEILING PLAN SYMBOLS GYP. BD. CEILING/SOFFIT EXISTING GYP. BD. CEILING/SOFFIT I SUSPENDED ACOUSTIC TILE CEILING EXISTING SUSPENDED ACOUSTIC TILE CEILING C J GYP. BD. CONTROL JOINT O z LIGHT FIXTURES; SEE ELECTRICAL DWGS. ® EXIT SIGN; SEE ELECTRICAL DWGS. ® SMOKE DETECTOR; SEE ELECTRICAL DWGS. ® ® MECHANICAL RETURN/SUPPLY DIFFUSER; SEE MECHANICAL DWGS. PROJECT: PINCHASERS ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 cy) O CDU N O H w L1J U (D w " ° .� w m o � O o LL u �10 �'� N "IT ^ v , Lu ' � D �4- �� z N ()6 LuO LLI U N N J N N Lu F- 0l< w� U N N o MLo a. STAMP: COLyyE�`✓9 • O —�Ir— p' • A 44r� ISSUE: DATE: ISSUED FOR PERMIT 01.25.2023 DRAWING SCALE: AS indicated DRAWN BY: CHECKED BY: Checker DRAWING TITLE: REFLECTED CEILING PLAN SHEET NUMBER: A2 • 0 SPRINKLER HEAD; SEE FIRE -PROTECTION DWGS. WN DOOR SCHEDULE SYM. DOOR FRAME DOOR HARDWARE SET DETAILS REMARKS/USE TYPE PANEL OTY. SIZE MATERIAL RATING FINISH TYPE MATERIAL RATING FINISH HEAD JAMB SILL DOOR PANEL WIDTH I HEIGHT THICKNESS PUSH PULL PUSH PULL existing plan 105A V T - 0" 1 1 /2" MTLJ GLASS PRE. PRE. * * * 01 107A V T - 0" 2" MTL./ GLASS PRE. PRE. 01 1 19A F SINGLE 3' - 0" 7' - 0" 1 3/4" WD. P P A H.M. P P 02 122A F PAIR 3 - 0" T - 0" 1 3/4" WD. P P A H.M. P P 03 2" AS 2" SCHEDULED w PRE -PRIMED, KNOCK DOWN HOLLOW METAL FRAME 0 w J 0 w 2 U 4 FRAME TYPE A FRAME TYPE LEGEND N.T.S. DOOR HARDWARE SCHEDULE HDWR. DOORS HARDWARE SET 01 105A - ALL HARDWARE TO BE PROVIDED WITH THE DOOR 107A MANUFACTURER FOR COMPLETE INSTALLATION. 02 119A 3 - HINGES 122A 1 - STOREROOM LOCKSET 1 - CLOSER 1 - DOOR STOP AS SCHEDULED FLUSH, w / SOLID PAINT GRADE DOOR. w a7 TL DOOR TYPE F 0 w J 0 w U Q DOOR TYPE LEGEND N.T.S. U) w a J w w W SILICONE SEALANT, TYP. (BOTH SIDES) HEAD DTL. SIM. AS SCHEDULED DOOR TYPE F TYP. JAMB DETAIL i 3" = 1'-011 DOUBLE ACTION SWING DOOR(S); ELIASON P1 1-PLUS ABS TRAFFIC DOOR. FINISH - AS SELECTED BY OWNER DOOR AS SCHEDULED (2) 20 GA. MTL. STUDS @ JAMB JAMB ANCHORS; (3) MIN. PER JAMB DOOR FRAME AS SCHEDULED GYP. BD WALL DOORS /FRAMES /HARDWARE NOTES 1. G.C. TO SUBMIT PRODUCT DATA / SHOP DRAWINGS TO ARCHITECT FOR APPROVAL FOR ALL DOORS, FRAMES, & HARDWARE PRIOR TO ORDERING ANY DOORS, FRAMES OR HARDWARE. 2. VERIFY ALL KEYING REQUIREMENTS WITH OWNER PRIOR TO ORDERING HARDWARE. 3. PROVIDE CORES FOR ALL LOCKSETS TO MATCH BUILDING STANDARD, IF APPLICABLE. CORES SHALL BE INTERCHANGEABLE AND CUSTOM KEYED TO SATISFY OWNERS NEEDS. 4. PROVIDE DOOR AND/OR FRAME MOUNTING PLATES WHERE REQUIRED FOR PROPER CLOSER INSTALLATION. 5. PREPARE STEEL FRAMES TO RECEIVE FINISH HARDWARE INCLUDING CUTOUTS, REINFORCING, DRILLING AND TAPPING. WELD EXPOSED MITERED JOINTS CONTINUOUSLY, GRIND, DRESS AND MAKE SMOOTH, FLUSH, AND INVISIBLE ALL WELDED JOINTS. SHOP PRIME EXPOSED SURFACES. 6. HINGES SHALL BE FULL MORTISE, FIVE KNUCKLE, FLAT TIP, COMMERCIAL BALL BEARING TYPE; STANLEY OR APPROVED EQUAL, UNLESS NOTED OTHERWISE. 7. LOCKSETS AND LATCHSETS SHALL BE SCHLAGE MEDIUM DUTY COMMERCIAL WITH LEVER STYLE HANDLES IN COMPLIANCE WITH ADA REQUIREMENTS, UNLESS OTHERWISE NOTED. 8. INTERIOR DOOR HARDWARE FINISH: SATIN CHROME US26D. 9. ALL NEW INTERIOR DOOR FRAMES TO HAVE FACTORY PRIMED, 16 GA. KNOCKDOWN HOLLOW METAL (UNLESS NOTED OTHERWISE). 10. PROVIDE MANUFACTURER'S STANDARD REINFORCING CLIPS AT KNOCK -DOWN FRAME CORNERS. 11. ALL DOOR HARDWARE TO BE ADA COMPLIANT. 12. UNLESS OTHERWISE NOTED, WOOD DOORS TO BE 5 PLY SOLID CORE. VENEER AND FINISH AS SCHEDULED. 13. CAULK ALL AROUND HEAD, JAMB, AND SILL, AT JUNCTURE OF H.M. FRAMES TO WALL FINISH. 14. VERIFY FRAME HEIGHTS BASED ON TOP OF SLAB AND FINISH FLOOR CONDITIONS AT EACH FRAME. 15. PROVIDE 20 GA DOUBLE STUD FRAMING AT JAMBS. 16. PROVIDE 1 /2" UNDERCUT AT BOTTOM OF DOORS UNLESS NOTED OTHERWISE, 17. THE HINGE SIDE OF ALL DOOR FRAMES SHALL BE LOCATED 4" FROM ADJACENT WALL UNLESS INDICATED/NOTED OTHERWISE @ NEW CONST. 18. PROVIDE MIN. (3) JAMB ANCHORS PER JAMB @ NEW DOOR FRAMES. 19. ALL DOOR HARDWARE TO BE FIRE RATED WHEN USED IN A FIRE RATED ASSEMBLY. 20. ALL DOOR CLOSERS SHALL BE COMPLIANT W/ STATE HANDICAP CODE OPENING FORCE REQUIREMENTS. 21. G.C. TO COORDINATE ALL SECURITY CAMERAS, WIRING, ELECTRIC STRIKES ETC. W/ DOOR AND HARDWARE SUPPLIER AND ELECTRICAL CONTRACTOR. PROJECT: PINCHASERS ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 STAMP: o0 CV 'jLj �J Q U u (D w D Q O 0 W m.§ 0 " O u C:) �10 10 — o� w L0 v , :D N 00 Z w O j F- Z N CV CIO Lu Z u.l N U �Cy I O Ln OF FAQ tz 00ACOLIV7 ' 7/7 — ' ISSUE: DATE: ISSUED FOR PERMIT 01.25.2023 DRAWING SCALE: AS indicated DRAWN BY: CHECKED BY: Checker DRAWING TITLE: DOOR SCHEDULE SHEET NUMBER: A701 ROOM FINISH SCHEDULE ROOM NO. ROOM NAME FLOOR BASE WALLS CEILING REMARKS NORTH EAST SOUTH WEST 101 ENTRY/ RECEPTION CP-1 RB-I TB-1 P- WS-1 ACT-1 102 SHOE ROOM CP-1 RB-I P- P- P- P- EXI. 103 BAR AREA 104 CORRIDOR 105 KITCHEN 106 WALK-IN COOLER 107 KITCHEN 108 ARCADE 109 MECH, 110 VEST. 1 1 1 WOMEN 112 VEST. 113 MEN 114 STOR. 115 PRO SHOP 116 RESTROOM 117 MECH. 118 SHOP 119 STORAGE 120 UTILITY 121 LOCKER ROOM 122 BAR 123 BOWLING AREA 124 MAINTENANCE AREA FINISH LEGEND SYM. DESCRIPTION MANUFACTURER PRODUCT STYLE & COLOR TEXTURE / FINISH FLAME SPREAD SMOKE DEVELOPMENT COMMENTS ACT-1 ACOUSTIC CEILING TILE CLASS A ACT-2 ACOUSTIC CEILING TILE CO-1 POLISHED CONCRETE CP-I BROADLOOM CARPET ENCORE HOSPITALITY CARPET PD266 CLASS 1 - ASTM E648 LESS THAN 450 GENERAL CARPET CP-2 BROADLOOM CARPET TBD ARCADE CARPET LVF-1 LUXURY VINYL FLOORING TILEBAR OPTORO TEKAPO OAK LOFT P-1 INTERIOR PAINT EGGSHELL GENERAL PAINT P-2 INTERIOR PAINT SHERWIN WILLIAMS IRON GATE - SW2926 EGGSHELL ACCENT PAINT P-3 INTERIOR PAINT SHERWIN WILLIAMS LIME RICKEY - SW6717 EGGSHELL ACCENT PAINT P-4 INTERIOR PAINT SHERWIN WILLIAMS IMPULSIVE PURPLE - SW6832 EGGSHELL ACCENT PAINT P-5 INTERIOR PAINT SHERWIN WILLIAMS RICE PADDY - SW6414 EGGSHELL ACCENT PAINT P-6 INTERIOR PAINT SHERWIN WILLIAMS FLAT GYP. BD. CLG./SOFFIT PAINT P-7 INTERIOR PAINT SHERWIN WILLIAMS MATCH ADJACENT WALL COLOR. SEMI -GLOSS DOOR AND DOOR FRAME PAINT PL-1 METAL LAMINATE CHEMETAL TBD PL-2 PLASTIC LAMINATE WILSONART WOOD GRAIN TBD PL-3 METAL LAMINATE CHEMETAL TBD BAR LAMINATE RB-I 4 "RUBBER BASE TARKETT SS-1 SOLID SURFACE QUARTZ TBD SS-2 SOLID SURFACE QUARTZ TBD ST-1 WOOD STAIN MINWAX TBD SEMI GLOSS T-1 FLOOR TILE QUARRY TILE AS SELECTED BY OWNER T-2 WALL TILE IVY HILL TILE HUDSON 12x24; COLOR GRAY TB-1 THIN BRICK BRICK IT AS SELECTED BY OWNER WB-1 1X6 WOOD BASE 1X6 MAPLE WD. ST-1 WC-1 WALL COVERING WALLS REPUBLIC BROWN CLIMBING FLORAL ORNAMENTAL MURAL WALLPAPER - #M9469 WP-1 WOOD PANELLING WEABER WEATHERED HARDWOOD BOARDS WS-1 WOOD SLATS 1x2 MAPLE WOOD ST-1 I i PROVIDE 1/2" BETWEEN SLATS.WALL TO BE PAINTED FLAT BLACK PRIOR TO INSTALLATION OF SLATS. FINISH NOTES 1. PROVIDE PRIMERS AND UNDERCOATS BY SAME MANUFACTURER OF FINISH COAT. USE ONLY THINNERS APPROVED BY PAINT MANUFACTURER AND USE ONLY WITHIN RECOMMENDED LIMITS. 2. PROVIDE THE FOLLOWING PAINT SYSTEMS BASED ON SUBSTRATE MATERIALS: 2.1. GYPSUM DRYWALL WALLS/CEILINGS/SOFFITS: EGGSHELL ACRYLIC -ENAMEL FINISH: TWO COATS OVER PRIMER 2.1.1. PRIMER: INTERIOR GYP. BD. PRIMER. 2.1.2. FINISH COATS: INTERIOR EGGSHELL ACRYLIC ENAMEL. 2.2. INTERIOR METAL FRAMES AND METAL TRIM: SEMI GLOSS ACRYLIC -ENAMEL FINISH: TWO COATS OVER A PRIMER 2.2.1. PRIMER: INTERIOR FERROUS -METAL PRIMER. 2.2.2. FINISH COATS: INTERIOR SEMI GLOSS ACRYLIC ENAMEL. 2.3. WOOD TRIM (STAINED): ALKYD -BASED STAIN SATIN -VARNISH FINISH: 2.3.1. FILLER COAT: OPEN -GRAIN WOOD FILLER (WHERE APPLICABLE) 2.3.2. STAIN COAT: INTERIOR WOOD STAIN 2.3.3. SEALER COAT: CLEAR SANDING SEALER 2.3.4. FINISH COATS: INTERIOR ALKYD- OR POLYURETHANE -BASED CLEAR SATIN VARNISH 3. ALL FINISHES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS. 4. PROVIDE VINYL COVE BASE AT VINYL TILE FLOORS. PROVIDE VINYL STRAIGHT BASE AT CARPETED FLOORS. 5. PAINT ALL ELECTRIC BACKBOARDS (ALL SIDES AND EDGES BEFORE MOUNTING). PAINT EXPOSED ELECTRIC PANELS (2 COATS BEFORE MOUNTING), EXPOSED ELECTRICAL RACEWAYS, BOXES AND FITTINGS. 6. PROVIDE TRANSITION STRIPS AT JUNCTION OF DISSIMILAR FLOORING MATERIALS. IF NOT OTHERWISE NOTED, PROVIDE VINYL STRIPS AT JUNCTION OF CARPET AND VINYL, AND METAL STRIPS (SCHLUTER, OR EQUAL, AT JUNCTION OF TILE FLOORS. SUBMIT PRODUCT DATA AND SAMPLES FOR COLOR SELECTION. 7. PRIOR TO APPLICATION OF VINYL WALL COVERING; PREPARE NEW GYP.BD. SUBSTRATE W/'SHERWIN WILLIAMS' PREPRITE 400 LATEX PRIMER OR EQUAL. 8. TILE SHALL BE THINSET WITH UNSANDED GROUT. 9. SUBMIT SAMPLES OF ALL COLORS ON VARIOUS SUBSTRATE MATERIALS SPECIFIED ON DRAWINGS, AS WELL AS ANY COLOR SUBSTITUTIONS REQUESTED BY OWNER, UNTIL FINAL APPROVAL OF PAINT AND STAIN COLORS IS OBTAINED. PROJECT: PINCHASERS ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 ` ci O ._,..I Cl) CD U N O J u < W = u .,,.� O r) Wm> O l CD 1-0O W Lo V)Ln �. cn Z ( , WOa0 V H � Z �N � N Lu Z 7- w N < (-) 06 N O �L0 I STAMP: ISSUE: DATE: ISSUED FOR PERMIT 01.25.2023 DRAWING SCALE: 1211 = 1'-0" DRAWN BY: CHECKED BY: Checker DRAWING TITLE: ROOM SCHEDULE SHEET NUMBER: A702 �IIAARIAIAAA�IAR!IAIAA9I�IIIIFiA�dAAIII�IA1011� 'p" Jl 1 A114 �1�022 -EAST ELEV. 4 BAR 122 -NORTH ELEV. -0 803 3'-6" 5"-0"" 5'-0" I I I I I I I I I I I I I 9`-4 P-5 a cm I I I I I I I i I I I I I I WP-1 807 I I I 1 I I I I I I soz 801 P-1 4 io I I I I I I I I I 1 I I I I I I P-5 I I I I I I I I I WP-1 WP-1 4'-6" 2'-0" 4'-6" 8'-0" 4'-6" 13'-5 1 /2" 8 BAR �003 - EAST LEV. 1/4-1 RECEPTION 101 - SOUTH ELEV. 1 /4" = 1'-0" 6 BAR 103 -SOUTH ELEV. RECEPTION 101 - NORTH ELEV. 1 /4" = 1'-0" 5 2 BAR 122 - SOUTH ELEV. 3 BAR 122 - WEST ELEV. 05BAR 103 - WEST ELEV. p 0 60 7 BAR 103 - NORTH ELEV. 114 801 ENTRY 101 - NORTH ELEV. 806 805 KEYNOTES - INTERIOR ELEVATIONS AND... 801 CUSTOM MILLWORK; SEE REFERENCED DETAIL 802 WALL MOUNTED TV MONITOR; PROVIDE IN WALL BLOCKING; SEE ELECTRICAL DRAWINGS 803 GYP.BD. CEILING/ SOFFIT 804 PROVIDE 1 X6 MAPLE WD. CAP. W/ STAIN FINISH 805 APPLY NEW WOOD SLATS (WS-1) OVER EXISTING MILLWORK 806 NEW SOLID SURFACE COUNTERTOP 807 WALL MOUNTED SCONCE LIGHT; SEE ELECTRICAL DWGS. 808 DISPLAY CASE FURNITURE; PROVIDED BY OWNER INSTALLED BY CONTRACTOR. PROJECT: PINCHASERS ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 CY) O CD U CN O u J �Lu W -3�: u �Q J o0 W o u 0110 � N �1' LuLo ' ^ Lo v, T 00 ZU WO LJJ W Li z c I CN CN W �N 0 z� Q wN U' N O Co Ln r STAMP: ISSUE: DATE: ISSUED FOR PERMIT 01.25.2023 DRAWING SCALE: 1 /4" = 1 0" DRAWN BY: CHECKED BY: Check21 DRAWING TITLE: INTERIOR ELEVATIONS SHEET NUMBER: A861 P-1 PROJECT: PINCHASERS ANTHONY PERRONE 808 1'-6" I 2'-9" L 2'-9" L V-6" L 8" L 5 BOTTLE SHELF DETAIL /2 0 7,-2„ x-n vx, BAR 122 - PLAN DETAIL 1 /2" = 1'-0" I BAR 103 - PLAN DETAIL. 1/2" = 1'-0" CORRIDOR 104 - SOUTH ELEV. 1/4" = 1'-0" BOWLING AREA - NORTH WALL 1/8" = 1'-0" GENERAL MILLWORK NOTES 1. ALL MILLWORK SHALL BE FABRICATED IN STRICT ACCORDANCE WITH THE ARCHITECTURAL WOODWORK INSTITUTE, "ARCHITECTURAL WOODWORK INSTITUTE QUALITY STANDARDS...', CUSTOM GRADE, UNLESS NOTED OTHERWISE. SHOP DRAWINGS ARE REQUIRED TO BE SUBMITTED AND APPROVED FOR ALL MILLWORK ITEMS PRIOR TO FABRICATION. PROVIDE ARCHITECTURAL WOODWORK INSTITUTE QUALITY CERTIFICATION PROGRAM LABELS OR CERTIFICATES INDICATING THAT THE WOODWORK, INCLUDING INSTALLATION, COMPLIES WITH REQUIREMENTS OF GRADES SPECIFIED. THE CONTRACTOR, UPON AWARD OF WORK, SHALL REGISTER THIS PROJECT WITH THE ARCHITECTURAL WOODWORK INSTITUTE QUALITY CERTIFICATION PROGRAM. (800) 449-881 1. 2. VERIFY ALL DIMENSIONS WITH CATALOG CUTS OF ACTUAL HARDWARE AND EQUIPMENT TO BE USED AND FIELD CONDITIONS. COORDINATE ROUGH -IN LOCATIONS WITH FIELD DIMENSIONS PRIOR TO FABRICATION. FIELD CUT COUNTERTOPS FOR INSTALLATION OF EQUIPMENT AND FIXTURES, TYPICAL. 3. SCRIBE AND CUT MILLWORK DURING INSTALLATION AS REQUIRED TO COMPENSATE FOR IRREGULAR WALL AND FLOOR SURFACES. INSTALLATION SHALL BE LEVEL, PLUMB AND TIGHT AT ALL FLOOR AND WALL SURFACES, CAULK ALL JOINTS WITH CLEAR SILICONE SEALANT. 4. PROVIDE WOOD OR SHEET METAL BLOCKING AS REQUIRED CONCEALED IN WALL CONSTRUCTION TO ADEQUATELY SUPPORT MILLWORK FOR ITS INTENDED USE IN THE LOCATIONS SHOWN. 5. ALL DRAWER AND CABINET PULLS SHALL BE AS SELECTED BY OWNER. 6. ALL DRAWERS SHALL HAVE TWO MEDIUM DUTY FULL EXTENSION DRAWER SLIDES AS MANUFACTURED BY "ACCURIDE", MODEL 3832, OR EQUAL. 7. EACH CABINET DOOR UP TO 42" IN HEIGHT SHALL HAVE TWO HINGES WITH 170 DEGREE OPENING AS MANUFACTURED BY "BLUM", MODEL CLIP 170, OR EQUAL. 8. PROVIDE (INSERT QUANTITY) HOLES IN COUNTERTOPS WITH BLACK PLASTIC GROMMETS FOR ELECTRICAL PLUG-IN CONNECTIONS RELATED TO MILLWORK ITEMS. VERIFY EXACT NUMBER AND LOCATIONS IN FIELD WITH OWNER'S REPRESENTATIVE. 9. UNLESS NOTED OTHERWISE, ALL BASE CABINETS/WALL CABINETS/COUNTERS SHALL BE CONSTRUCTED OF 3/4" MEDIUM DENSITY FIBERBOARD WITH PLASTIC LAMINATE FINISH. (SEE DETAILS). 10. UNLESS NOTED OTHERWISE, ALL COUNTERTOPS WITH PLUMBING FIXTURES/ SINKS SHALL BE CONSTRUCTED OF 3/4" MEDEX (WATER RESISTANT HIGH DENSITY FIBERBOARD) WITH PLASTIC LAMINATE FINISH. (SEE DETAILS). 11. UNLESS NOTED OTHERWISE, INTERIOR CONCEALED SURFACES SHALL BE FINISHED WITH MELAMINE (LOW PRESSURE LAMINATE). SUBMIT SAMPLES FOR COLOR SELECTION, IF COLORS ARE NOT SPECIFIED IN DETAILS. 12. BASE CABINETS SHALL BE 2'-0" DEEP, UNLESS OTHERWISE NOTED. WALL CABINETS SHALL BE 1'-2" DEEP, UNLESS OTHERWISE NOTED. 13. PROVIDE CUT-OUTS IN MILLWORK ITEMS AS REQUIRED TO ACCOMMODATE JUNCTION BOXES AND OTHER ELECTRICAL DEVICES AS REQUIRED. COORDINATE WITH DETAILS AND ELECTRICAL DRAWINGS, IF ANY. 14. FOR ALL WOOD VENEER WALL PANELS, CONTRACTOR SHALL VERIFY GRAIN PATTERN CUT AND REPEAT WITH PROJECT DESIGNER PRIOR TO FABRICATION. 15. UNLESS NOTED OTHERWISE, INTERIOR CONCEALED SHELVING SHALL BE MELAMINE (LOW PRESSURE LAMINATE, COLOR TO MATCH CABINETS). EXPOSED SHELVING SHALL BE 3/4" PLYWOOD WITH PLASTIC LAMINATE FINISH. EDGES OF ALL SHELVING SHALL BE FINISHED WITH POLYETHYLENE TEE MOLDING (COLOR TO MATCH CABINETS.) 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 ♦ ^ �/ J Co U Co J N O < Lu Lu =U �a °o � W 0 X O LL u CD �O o N �t r ^ �/ I u_J ~ N 06 z U wO LLJ �� N z N �N Lu Q w06 U N 06 N O c>7 uo -mama r- STAMP: ISSUE: DATE: ISSUED FOR PERMIT 01.25.2023 DRAWING SCALE: As indicated DRAWN BY: CHECKED BY: Checker DRAWING TITLE: INTERIOR ELEVATIONS AND PLAN DETAILS SHEET NUMBER: A802 -1 T- SOLID SURFACING COUNTER OVE" "' " SS-2 1 1/2" DIA WIN FABRIC PADDII` 3/4" MDF FINS 3/4" MDF W/ P. PL-3 BAR EQUIPMEI, 2" DIA. BAR FO, PROVIDE SUPP( O.C. MAX, ANC FROM CORNEF RUBBED BRON; 1 1/2" DIA WIRI OSECTION BAR -12 3/4" MDF COUNTER W/ P.LAM FINISH WALL BRACKET; RAAKS, EH1212,BLACK POWDER COAT 0,2R INK COUNTER DETAIL 1 112" = 1'-0" SECTION ( 1 1/2" = 1'-0" SOFFIT DETAIL 1 1 /2" = 1'-0" BOTTLE CABINET EXTEND MTL. STUDS TO DECK ABOVE EXISTING ACT CEILING GRID 2 1/2" MTL. STUDS @ 16" O.C. LED TAPE; SEE ELEC. DWGS. EXISTING/ WALL NEW WALL CONSTRUTION. WOOD PANEL DETAIL 1 1/2" = 1'-0" 2'-2" 0_�jE CTION BAR 1 1 /2 - 1 -0 ZENCH CLEAT @ 24" DF SOLID SURFACING COUNTERTOP SS-1 LED TAPE LIGHT; SEE ELEC. DWGS. PROVIDE 1 1/2" DIA WIRING CHASE BAR EQUIPMENT; PROVIDED BY OWNER 3/4" MDF FINS @ 16" O.C. 3/4" MDF W/ P.LAM FINISH PROVIDE 1 1/2" DIA WIRING CHASE 01E CTION BOTTLE SHELF PROJECT: PINCHASERS ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 Ln CO O CD U N O u Lu LLJ u F- = U DQ 06 LLJ m O > X L U 1° C) 110 CN (� , w Ln v Z ao F- CD UW ce Li ~N c/) z N N W Q Z v LU N U 06 N CD CV) Lo h STAMP: 2 At� O lF_ 0+ M COL ., • A 449 RED AaG .. DRAWING SCALE: 1 1 /21' = 1 0" DRAWN BY: CHECKED BY: Checker DRAWING TITLE: INTERIOR DETAILS SHEET NUMBER: PLUMBING FIXTURE CONNECTION SCHEDULE P-NO. DESCRIPTION WASTE VENT HOT COLD REMARKS P-4 MOP SINK 3" 2" 3/4" 3/4" FIAT STONE MOP SINK TERRAllO #TSB100 W/ CHICAGO SER\ACE FAUCET MODEL #897-CP, STAINLESS STEEL WALL GUARDS #MSG2424 AND RIM GUARDS TO SUIT INSTALLATION. PROVIDE MOP HANGER #889-CC, HOSE AND BRACKET#832-AA WITH 2' X6 WOOD BACKING FOR FAUCETAND CHROME GRASS STRAINER. FAUCETTO MEET LEAD-FREE REQUIREMENTS. BC-1 BAR CASEWORK 1-1/2" ID 1/2" 1/2" ALL OWNER FURNISHED BA R EQUIPMENT CONNECT NEW 1/2" H&CW WITH 1-1/2" ID WASTE TO BAR EQUIPMENT AS REQUIRED. PROVIDE ALL FINAL CONNECTIONS PLUMBING SYMBOL LEGEND SYMBOL El �I �IH 1. 1. —0 0 —90 —D411 4 0 1 8" FT A ABV. DESCRIPTION S/W DOUBLE LINES INDICATE PIPE BURIED V VENT PIPE BURIED S/W SOIL/WASTE PIPE ABOVE FLOOR SLAB V VENT PIPE ABOVE FLOOR SLAB CW COLD WATER PIPE HW HOT WATER PIPE HWR HOT WATER RECIRCULATION PIPE E EXISTING PIPE IW INDIRECT WASTE DIRECTION OF FLOW PLUMBING FIXTURE DESIGNATION PIPE CAP PIPE CONTINUATION B FP REDUCED PRESSURE BACKFLOW PREVENTER SV BALL OR GATE SHUTOFF VALVE FCO FLOOR CLEANOUT CV CHECK VALVE DV DRAIN VALVE SOLENOID VALVE WIRED BY E.C. WHA WATER HAMMER ARRESTOR TAG; SEE SCHEDULE FD FLOOR DRAIN - SEE SCHEDULE CTE CONNECT TO EXISTING AP ACCESS PANEL WCO WALL CLEANOUT OR PLUG CLEANOUT DCO DANDY CLEANOUT PG PRESSURE GAUGE UNION TEE OFF TOP TEE OFF BOTTOM DROP AND RUN DROP AND TURN TEE UP TEE DOWN UP PIPE UP AND / OR RISE DP/DN PIPE DROP / DOWN W&T WASTE & TRAP NFWH NON -FREEZE WALL HYDRANT HB HOSE BIBB - SEE DETAIL VB VACUUM BREAKER TH THERMOMETER MX MIXING VALVE T&P TEMPERATURE AND PRESSURE RELIEF VALVE HVAC UNIT DESIGNATION - SEE HVAC DRAWINGS BAL BALANCING STATION PIPE SLOPE TP TRAP PRIMER AFC ABOVE FINISH CEILING BFF BELOW FINISH FLOOR VTR VENT THRU ROOF EC ELECTRICAL CONTRACTOR GC GENERAL CONTRACTOR Sc SITE CONTRACTOR PC PLUMBING CONTRACTOR TYP TYPICAL AFF ABOVE FINISHED FLOOR BFF BELOW FINISHED FLOOR AFC ABOVE FINISHED CEILING NC NORMALLY CLOSED NO NORMALLY OPEN WHA WATER HAMMER ARRESTOR GPF GALLONS PER FLUSH GPM GALLONS PER MINUTE ST.ST. STAINLESS STEEL DIN DOWN SD STORM DRAIN PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 o N U oU Lu W QU i= U CD � �Q O U af 0 Lu ° � O X3: O10 U ,10 o 'ITN � d' W Lf) F- Ln r ,� �•/ J = C) Ln OD 0 L rn UwW z W. af � N < N z �r CN Z N W W U 00 o N � M Q � a� V x O O � � iAi1, 0 •'.y M Wr. u N 0 s::i pm O 000oc U �.., U "d 4:1 0 N Z M 00 3 STAMP: !!:!i?lilttr�!!/tip R4ijk ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: LRV CHECKED BY: FZ DRAWING TITLE: PLUMBING - LEGENDS & SYMBOLS DRAWING NUMBER: POO BOWLING AREA 123 ,. 1 CORRIDOR 104 ASSUMED LOCATION OF EXISTING BATHROOM SANITARY WASTE MAIN. THIS CONTRACTOR TO VERIFY EXACT LOCATION OF MAIN & INVERT p ;jl A ELEVATION PRIOR TO ANY NEW CONSTRUCTION. THIS CONTRACTOR TO ENSURE THE PITCH WILL WORK TO THE NEW BAR AREA. I I _ I� ��— A 0 'I I, l � C ARCADE 108 �J 1 I PLUMBING NEW WORK - WASTE & VVENT SCALE:1/8" =1'-0" i 0 8'-0" 164" 24'-0" BOWLING AREA 123 ALL BATHROOM FIXTURES ARE EXISTING TO REMAIN! NEW 3/4" H&CW DN � RUN PIPING UNDER CASEWORK TO n MECH.. EQUIPMENT AS REQ'D. COORDINATE WITH BAR EQUIPMENT SUPPLIER. 117 RESTROOM CONNECT TO EXISTING H&CW - VERIFY EXACT LOCATION IN FIELD f _j PRO SHOP 116 °� VEST. VEST. �Ivi�9n, �-�� j 115 112 110 EN sc 1 j I 3/4" 1" H&CW �! CTE 113 O WOMEN — — — — — — 111 } I LOCKER ROOM 0I El BAR —I 122 _.__j _ . 1 SHOP 7 118 P 4 (TO ALL BATHROOM FIXTURES A 3/4" H&CWS DN TO MOP SINK UTILITY 120 CORRIDOR 104 ALL BATHROOM FIXTURES ARE EXISTING TO REMAIN! ARCADE 108 _a /. PLUMBING NEW WORK - WATER SCALE:1/8" =1'-0" 0 8'-0" 16-0" 24'-0" KITCHEN 105 WALK-IN COOLER 106 KITCHEN 107 t j- PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 Lo co "' O O N U OU L1J Q w � I- U�� �Q 0 U ime Wm� O� w� co 10 O �1' � N V w �n H Ln r n V) 00 � I (D Lo z w. U ww F' N v) N QN z ry Lu ZN w U co o� CV r) < CL J :ter. N U .N M kn O 00 00 O a 00 STAMP: 0"4.4+I64Ii4,0" t M� tt �� i I o: i 1' TART F FLORI1 •:��? ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: LRV CHECKED BY: FZ DRAWING TITLE: PLUMBING - NEW WORK PLAN WATER, WASTE & VENT DRAWING NUMBER: P 1 • 0 PART IGENERAL 1.01 GENERAL CONDITIONS THE APPLICABLE PROVISIONS OF THE GENERAL CONSTRUCTION SPECIFICATIONS SHALL APPLY TO THE FOLLOWING SPECIFICATIONS ARTICLES. A. THE SPECIFICATIONS AND DRAWINGS ARE INTENDED TO SERVE JOINTLY AS A BASIS UPON WHICH THE CONTRACTOR SHALL SUBMIT A CONTRACT PRICE FOR THE MATERIAL AND LABOR PROVISIONS. B. WHEN CONFLICTS OCCUR IN THE SPECIFICATIONS OR ON THE DRAWINGS, OR BETWEEN EITHER, THE ITEMS OF GREATER QUANTITY OR HIGHER COST SHALL BE PROVIDED. C. THE CONTRACTOR SHALL PROVIDE ALL ITEMS OF LABOR AND MATERIALS NOT SPECIFICALLY INDICATED, BUT REQUIRED TO COMPLETE THE INTENDED INSTALLATION. D THE CONTRACTOR SHALL COORDINATE HIS WORK OR ADJUST SA T THAT F THE N ME 0 0 OTHER TRADES, IN ORDER THAT CONFLICTS IN SPACE LOCATIONS DO NOT OCCUR. E. THE WORK UNDER THIS CONTRACT SHALL BE PERFORMED SIMULTANEOUSLY WITH WORK OF OTHER TRADES, SO AS NOT TO DELAY THE OVERALL PROGRESS OF WORK. F. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK WITH ITS COMPLETION AND FINAL ACCEPTANCE AND SHALL REPLACE ANY IF SAME WHICH MAY BE DAMAGED, LOST OR STOLEN, WITHOUT ADDITIONAL COST TO THE OWNER. G. ALL PLUMBING WORK SHALL BE PERFORMED BY A STATE LICENSED PLUMBER IN STRICT ACCORDANCE WITH AHJ, STATE & LOCAL CODES AND REQUIREMENTS. H. PROVIDE ALL TRANSPORTATION, FREIGHT, LOADING AND UNLOADING AND PROVIDE ALL LABOR NECESSARY FOR ERECTING IN PLACE OF ALL MATERIAL AND EQUIPMENT SHOWN, SPECIFIED OR REQUIRED UNDER THIS DIVISION. 1.02 SCOPE OF WORK: A. WITHOUT LIMITING GENERALITY, PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE PLUMBING SYSTEM AS DESCRIBED BELOW: 1. SANITARY, WASTE AND VENT PIPING SYSTEM. 2. DOMESTIC WATER PIPING SYSTEM. 3. PLUMBING FIXTURES & TRIM. 4. PIPE INSULATION, SLEEVING AND FIRESTOPPING. 5. HANGERS SUPPORTS ACCESS PANELS DOORS. 6. FLUSHING, DISINFECTING, TESTING AND BALANCING. 7. PERMITS & FEES. 8. CONNECTIONS TO EXISTING PIPING OR EQUIPMENT. 9. TRENCHING, BACKFILLING, COMPACTING, CORING, CUTTING, AND PATCHING. 10. DOMESTIC WATER HEATING SYSTEM 11. NATURAL GAS SYSTEM 12. BAR EQUIPMENT CONNECTIONS & GREASE TRAP 13. PART II PRODUCTS 2.01 PIPING A. WATER PIPING ABOVE SLAB, SHALL BE TYPE "L" COPPER ASTM-13-88 WITH (95-5) TIN -ANTIMONY SOLDERED JOINTS & WROUGHT FITTINGS. WATER PIPING BELOW SLAB, SHALL BE TYPE "K" SOFT COPPER TUBING "ONE PIECE -WITHOUT JOINTS". B. ALL EXPOSED WASTE AND WATER PIPING SHALL BE CHROME PLATED. C. WASTE & VENT PIPING BELOW THE SLAB, SHALL BE STANDARD WEIGHT, BELL & SPIGOT CAST IRON, PIPE & FITTINGS. D. WASTE AND VENT PIPING ABOVE THE SLAB, SHALL BE HUBLESS CAST IRON, PIPE & FITTINGS, ASTM-A-74, MANUFACTURED AND INSTALLED IN ACCORDANCE WITH C.I.S.P.I. STANDARD 301 AND PAMPHLET 100. JOINTS SHALL BE MADE WITH CLAMP RETAINER SLEEVE AND NEOPRENE GASKET. NO -HUB COUPLINGS SHALL BE HEAVY DUTY C.I. COUPLINGS AS MANUFACTURED BY CLAMP -ALL "125" SERIES OR HUSKY "SD 4000" SERIES. E. GAS PIPING ABOVE GRADE SHALL BE SCH 40 SEAMLESS BLACK STEEL, ASTM A53 GRADE A WITH MALLEABLE IRON FITTINGS CONFORMING TO ANSI/ASME B16.3. F. PROVIDE ALL NECESSARY SUPPORTS, HANGERS, BRACES, ANCHORS, PADS AND ALL ELSE NECESSARY FOR THE ENTIRE INSTALLATION AND TO MEETTHE INTENT OF THE SYSTEMS FOR PROPER OPERATION. G. PIPE AND EQUIPMENT SUSPENSION SHALL BE SUCH AS TO PREVENT EXCESSIVE STRESS, EXCESSIVE VARIATION IN SUPPORTING FORCE, POSSIBLE RESONANCE WITH IMPOSED VIBRATION WHILE THE SYSTEM IS IN OPERATION CREEPING, SAGGING, BUCKLING, OR MISALIGNMENT. H. SYSTEMS SHALL OPERATE UNDER ALL CONDITIONS OF LOAD WITHOUT ANY OBJECTIONAL SOUND OR VIBRATION. 1. OPENINGS IN EXTERIOR WALLS OR ROOF SHALL BE KEPT PROPERLY PLUGGED AND CAULKED AT ALL TIMES EXCEPT WHEN BEING WORKED ON TO PRECLUDE THE POSSIBILITYFLOODING DUE OF N TO STORM OR OTHER CAUSES. AFTER COMPLETION OF WORK OPENINGS SHALL BE PERMANENTLY SEALED AND CAULKED IN A MANNER APPROVED BY THE ENGINEER OR ARCHITECT. J. PROVIDE DI -ELECTRIC FITTINGS BETWEEN DISSIMILAR METALS. 2.02 BIDDING CONFLICTS: A. IF CONFLICTS OCCUR WITHIN THESE SPECIFICATIONS OR ON THE DRAWINGS, OR EITHER, BETWEEN THE ITEMS OF GREATER QUANTITY OR HIGHER COST SHALL BE BID AND PROVIDED. 2.03 SMOKE AND FIRESTOPPING: A. FIRESTOP ALL PENETRATIONS BETWEEN FLOORS & FIRE RATED WALLS WITH APPROVED FIRE STOPPING ASSEMBLIES AS MANUFACTURED BY 3M INDUSTRY, HILTI OR APPROVED EQUAL. THE ASSEMBLIES SHALL COMPLY WITH THE LATEST APPLICABLE REQUIREMENTS OF THE: BUILDING CODE, NFPA STANDARDS AND OWNERS INSURANCE COMPANY. PROPOSED APPLICABLE ASSEMBLIES SHALL BE UL LISTED AND SHALL BE PART OF THE PLUMBING EQUIPMENT SUBMITTAL. B. ALL PIPING PASSING THROUGH FIRE -RATED WALLS, SLABS, FLOORS, ETC. SHALL HAVE STEEL SLEEVES EXTENDING 2" BEYOND SURROUNDING SURFACE. THE SPACE BETWEEN THE PIPES AND THE SLEEVES SHALL BE COMPLETELY PACKED WITH AN APPROVED FIRESTOPPING MATERIAL. AFTER FIRESTOPPING MATERIAL HAS BEEN INSTALLED AROUND PIPES, A 26" GAUGE SHEET METAL COLLAR SHALL BE SECURED AROUND THE PIPE TO INSURE TIGHTNESS. 2.04 INSULATION: A. ALL INSULATION WHEN INSTALLED SHALL HAVE COMPOSITE FIRE AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE ASTM-E-84, NFPA-255, AND UL-723, NOT EXCEEDING A FLAME SPREAD OF 25 AND SMOKE DEVELOPED OF 50 WHEN COMPARED WITH RED OAK AS 100, AS APPROVED UNDER NFPA AND NBFU PAMPHLET NO. 90A AND NO. 90B STANDARDS. B. DOMESTIC WATER PIPING ABOVE GROUND SHALL BE INSULATED WITH FIBERGLASS INSULATION WITH FACTORY -APPLIED ALL -SERVICE JACKET SECURED IN PLACE WITH SELF SEALING LAPS. FITTINGS SHALL BE INSULATED WITH PREMOLDED PVC COVERS SECURED IN PLACE WITH STAINLESS STEELTACKS. DOMESTIC WATER PIPING BELOW GROUND SHALL BE INSULATED WITH 1/2" THICK "ARMAFLEX" ELASTOMERIC UNICELLULAR SEAMLESS INSULATION. C. PIPING INSULATION MATERIALS AS MANUFACTURED BY GUSTIN BACON, JOHNS MANVILLE, OWENS-CORNING, KNAUF, OR CERTAIN TEED. D. ABOVE GROUND PIPING: INSULATION THICKNESS: 1, DOMESTIC COLD WATER: 1" THICK 2. DOMESTIC HOT WATER & HOT WATER RETURN: 1" THICK 2.05 ACCESS PANELS: A. FURNISH ALL ACCESS PANELS FOR WALLS AND CEILINGS. COORDINATE THE ACCESS PANEL LOCATION WITH GENERAL CONTRACTOR. PIPING SHALL BE LAID OUT IN SUCH A MANNER AS TO MINIMIZE THE NUMBER OF ACCESS PANELS REQUIRED. MILCOR PRODUCTS, VENTLOCK, KNAPP. MINIMUM SIZE: 8" X 8". B. PROVIDE ACCESS PANELS FOR ALL CLEANOUTS, VALVES, AND OTHER CONCEALED ACCESSORIES REQUIRING ACCESS SUCH AS SHOCK ABSORBERS, CONTROL VALVES, PRESSURE REDUCERS, AIR ARRESTORS, ETC. 2.06 IDENTIFICATION, MARKING AND TAGGING: A. EQUIPMENT IDENTIFICATION: 1. MANUFACTURER'S NAMEPLATES OR TRADEMARK SHALL BE PERMANENTLY AFFIXED TO ALL EQUIPMENT AND MATERIALS FURNISHED UNDER THIS DIVISION. MFG'S NAMEPLATES SHALL INCLUDE ALL PERTINENT DATA RELATIVE TO THE PIECE OF EQUIPMENT INCLUDING MODEL NUMBER, SERIAL NUMBER, AND OPERATING CHARACTERISTICS AS APPLICABLE. 2. SEPARATE EQUIPMENT IDENTIFICATION MARKERS SHALL IDENTIFY EACH ITEM OF EQUIPMENT WITH A PERMANENTLY ATTACHED MARKER INDICATING DESIGNATION AND/OR NUMBER CORRESPONDING TO DESIGN DOCUMENTS E.G. WH-1, WH-2, ETC. 3. MARKERS SHALL BE OF RIGID BLACK BAKELITE OR PHENOLIC CONSTRUCTION WITH WHITE ENGRAVED OR INCISED LETTERS. 4. LETTERING ON EQUIPMENT MARKERS SHALL BE OF ADEQUATE SIZE TO BE LEGIBLE FROM FLOOR LEVELS. MARKER LETTERING SHALL NO BE LESS THAN 1 INCH HIGH. 5. MOUNT EQUIPMENT IDENTIFICATION NAMEPLATES IN A CONSPICUOUS PLACE ON THE EQUIPMENT. 6. FOR EQUIPMENT MOUNTED ABOVE THE FLOOR LEVEL, MOUNT IDENTIFICATION NAMEPLATE SO THAT THEY CAN BE SEEN FROM FLOOR LEVEL. 7. ATTACH NAMEPLATES WITH RIVETS. GENERAL PLUMBING SPECIFICATIONS B. PIPING SYSTEM IDENTIFICATION: 1. PIPING SYSTEMS SHALL BE IDENTIFIED AS INDICATED HEREIN OR AS REQUIRED BY APPLICABLE CODES AND/OR OFFICIALS HAVING JURISDICTION. 2. PIPE MARKERS SHALL BE COLOR CODED ACCORDING TO "TABLE 2: CLASSIFICATION OF MATERIALS AND DESIGNATIONS TO COLORS" - ANSI A13.1-1981. 3. PIPE MARKERS SHALL INDICATE DIRECTION OF FLOW, SYSTEM, OPERATING PRESSURE AND TEMPERATURE. 4. PIPE MARKERS SHALL BE OF THE PRESSURE SENSITIVE TYPE AS MANUFACTURED BY THE SETON NAMEPLATE CORP. (F10-CODE) S. PIPE MARKERS SHALL BE INSTALLED AT EVERY POINT OF ENTRY AND EXIT THROUGH FLOORS, WALLS, CEILINGS OR OTHER CONCEALMENT, ON EACH RISER, TAKE -OFF AND BRANCH AND AT EACH PIECE OF EQUIPMENT. 6. tM PE TALL N5 I MARKERS RKERS AT A DISTANCE OF NOT LESS THAN 25 FEET APART IN CONTINUOUS CLEARLY VISIBLE. LENGTHS OF PIPE LINES AND ORIENTED SO THAT MARKERS ARE WHEN PIPE LINES ARE LOCATED ABOVE THE NORMAL LINE OF VISION, THE MARKER SHALL BE PLACED BELOW THE HORIZONTAL CENTERLINE OF THE PIPE. C. VALVE IDENTIFICATION: 1. PROVIDE LAMINATED PLASTIC NAMEPLATES ON ALL VALVES INSTALLED UNDER DIVISION 15, EXCEPT STOP VALVES IN SUPPLIES TO FIXTURES. TAGS SHALL BE CONSTRUCTED OF 0.125 INCHES THICK MELAMINE PLASTIC CONFORMING TO FED. SPEC. L-P-387. SURFACE SHALL BE MATTE FINISH. ACCURATELY ALIGN LETTERING AND ENGRAVE INTO WHITE CORE. HALL BE 0 2 INCHES ROUND OR HEXAGONAL. LETTERING SHALL BE NAMEPLATES S T R 0 MINIMUM OF 0.375 INCH HIGH NORMAL BLOCK LETTERING. KEY THE NAMEPLATES TO A CHART AND SCHEDULE FOR EACH SYSTEM UNDER GLASS AND PLACE WHERE DIRECTED IN MECHANICAL ROOM. FURNISH FOUR COPIES OF EACH CHART AND SCHEDULE. EACH INSCRIPTION SHALL IDENTIFY IT'S FUNCTION. ATTACH NAMEPLATES WITH "S" HOOKS AND CHAIN TO EACH VALVE. VALVE NAMEPLATES SHALL BE NUMBERED AND "KEYED" AS FOLLOWS: a. PLUMBING NAMEPLATES SHALL BE RED IN COLOR AND INDICATE: AA. "CW" COLD WATER BB. "HW" HOT WATER -INDICATE DESIGN TEMPERATURE OF WATER CC. "HWR" HOT WATER RETURN b. CHART AND SCHEDULE SHALL INDICATE THE FOLLOWING INFORMATION: AA. MANUFACTURER, TYPE, AND MODEL NUMBER BB. CAPACITY OR SIZE CC, SYSTEM IN WHICH IT IS INSTALLED DD. SYSTEM OR EQUIPMENT WHICH IT CONTROLS EE. LOCATION KEYED INTO VALVE NUMBER c. VALVE TAGS AND CHAIN SHALL BE SECURELY ATTACHED TO THE VALVE SO THAT NORMAL OPERATION OF THE VALVE OR TAMPERING WILL NOT ALLOW IT TO BE REMOVED. 2.07 SLEEVES, INSERTS AND ESCUTCHEONS: A. PROVIDE SLEEVES FOR ALL WORK PASSING THROUGH FLOOR, WALL, AND CEILING CONSTRUCTION. MAINTAIN ALL RATINGS. B. LOCATE AND PROVIDE SLEEVES AND INSERTS BEFORE THE FLOOR, WALL OR CEILING IS CONSTRUCTED. IF THIS CONTRACTOR DOES NOT COMPLY WITH THE ABOVE, HE SHALL BEAR ALL COSTS INCURRED FOR CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF SLEEVES AND INSERTS. HOLES REQUIRED FOR SLEEVES IN EXISTING WALLS AND FLOORS, OR TO CONFORM TO THE ABOVE, SHALL BE SAW CUT OR CORE DRILLED. THIS CONTRACTOR SHALL PROVIDE ALL DRILLING REQUIRED FORTHE INSTALLATION OF HANGERS. C. PIPE SLEEVES THROUGH OUTSIDE WALLS AND SLAB -ON -GRADE FLOOR SHALL BE SCHEDULE 80 BLACK STEELPIPE WITH 150 LB. BLACK STEEL SLIP-ON WELDED FLANGES WELDED AT THE LA CENTER OF THE OUTSIDE. EXTEND SLEEVES1 2 INCHES BEYOND EACH SIDE OF THE WALL. PACK THE SPACE BETWEEN SLEEVE AND PIPE WITH OAKUM TO WITHIN 2 INCHES OF EACH FACE OF THE WALL. PACK THE REMAINING SPACE AND MAKE WATERTIGHT WITH AN APPROVED WATERPROOF COMPOUND. (INSIDE FACE OF SLAB -ON -GRADE FLOOR.) FOR EXISTING WALL CONSTRUCTION, CENTER FLANGE WILL NOT BE REQUIRED. D. PIPE SLEEVES THROUGH CONCRETE FLOORS OR INTERIOR MASONRY WALLS SHALL BE SCHEDULE SL S OU E E 0 40 BLACK STEEL PIPE, SET FLUSH WITH FINISHED WALL OR CEILING SURFACES, BUT EXTENDING 2 INCHES ABOVE FINISHED FLOORS. PLASTIC, PVC, OR LIGHT METAL SLEEVES SHALL NOT BE INSTALLED. E PROVIDE 0 STRIP TYPE INSERTS PRESSED STEEL CONSTRUCTION WITH E. PR E R D T ACCOMMODATION FOR REMOVABLE NUTS AND THREADED RODS UP TO 3/4 INCH DIAMETER, PERMITTING LATERAL ADJUSTMENT. INDIVIDUAL INSERTS SHALL HAVE AN OPENING AT THE TOP TO ALLOW REINFORCING RODS TO 1/2 INCH DIAMETER TO BE PASSED THROUGH THE INSERT BODY AND SHALL BE SIMILAR TO FEE AND MASON MANUFACTURING COMPANY FIGURE 178. STRIP INSERTS SHALL HAVE ATTACHED RODS WITH HOODED ENDS TO ALLOW FASTENING TO REINFORCING RODS SHALL BE SIMILAR TO FEE AND MASON MANUFACTURING COMPANY. F. WHERE PIPE MOTION DUE TO EXPANSION AND CONTRACTION WILL OCCUR, MAKE SLEEVES OF SUFFICIENT DIAMETER TO PERMIT FREE MOVEMENT OF PIPE. WHERELL SLEEVES PASS INSULATED PIPES, THE SLEEVES SHALL BE LARGE ENOUGH TO PASS THE PIPE AND THE INSULATION. CHECK FLOOR AND WALL CONSTRUCTION FINISHES TO DETERMINE PROPER LENGTH OF SLEEVES FOR VARIOUS LOCATIONS. G. ESCUTCHEON PLATES SHALL BE PROVIDED FOR ALL EXPOSED UNINSULATED PIPES PASSING THROUGH WALLS, FLOORS, AND CEILINGS. PLATES SHALL BE NICKEL PLATED, OF THE SPLIT RING TYPE, OF SIZE TO MATCH THE PIPE. WHERE PLATES ARE PROVIDED FOR PIPES PASSING THROUGH SLEEVES WHICH EXTEND ABOVE THE FLOOR SURFACE, PROVIDE DEEP RECESSED PLATES TO CONCEAL PIPE SLEEVES. H. PACK THE SPACE BETWEEN SLEEVES AND STRUCTURE, AND SLEEVES AND PIPES PASSING THROUGH FIRE RATED INTERIOR WALLS, FLOORS, AND CEILINGS WITH AN APPROVED FIRE AND SMOKE PROOF PACKING MATERIAL. FIRE -STOPPING MATERIAL SHALL MAINTAIN ITS DIMENSIONS AND INTEGRITY WHILE PREVENTING THE PASSAGE OF FLAME, SMOKE, AND GASES UNDER CONDITIONS OF INSTALLATION AND USER WHEN EXPOSED TO THE ASTM E119 TIME -TEMPERATURE CURVE FOR ATIME PERIOD EQUIVALENT TO THE RATING OF THE ASSEMBLY PENETRATED. COTTON WASTE SHALL NOT IGNITE WHEN PLACED IN CONTACT WITH THE NON -FIRE SIDE DURING THE TEST. FIRE -STOPPING MATERIAL SHALL BE NON-COMBUSTIBLE AS DEFINED BY ASTM E136; AND IN ADDITION, FOR INSULATION MATERIALS, MELT POINT SHALL BE A MINIMUM OF 1700 DEGREES F. FOR 1-HOUR PROTECTION AND 1850 DEGREES F. FOR 2-HOUR PROTECTION. I. FASTEN SLEEVES SECURELY IN FLOORS, WALLS, ETC. SO THAT THEY WILL NOT BECOME DISPLACED WHEN CONCRETE IS POURED OR WHEN CONSTRUCTION IS BUILT AROUND THEM. TAKE PRECAUTIONS TO PREVENT CONCRETE, PLASTER, OR OTHER MATERIALS BEING FORCED INTO THE SPACE BETWEEN PIPE AND SLEEVE DURING CONSTRUCTION. 17_112IIIIWA: to1111111 II1810I 3.01 WATER SYSTEM: A. PIPING SHALL BE RUN PARALLEL WITH THE LINES OF THE BUILDING; WELL SUPPORTED FROM THE STRUCTURE: FREE FROM POCKETS AND SAGS: PITCHED TO DRAIN POINTS; AND INSTALLED WITH PIPE EXPANSION LOOPS, MECHANICAL EXPANSION JOINTS, PIPE GUIDES, OFFSETS AND ANCHORS TO ADEQUATELY PROVIDE FOR THERMAL EXPANSION. B. ABOVE GROUND PIPING SHALL BE INSTALLED TO PROVIDE NOT LESS THAN 3/4" SPACING FROM FINISHED COVERING TO OTHER COVERING OR SURFACES OF OTHER CONSTRUCTION. SEPARATE BELOW GROUND H & CW PIPING THAT ARE TO BE INSTALLED IN THE SAME TRENCH, BY A MINIMUM OF 12". PIPE SHALL HAVE LONG TURN RADIUS TURNS WITHOUT KINKS. PIPING SHALL NOT MAKE CONTACT WITH OTHER PIPE, CONDUIT REINFORCING STEEL OR CONCRETE. C. ALL PIPING SHALL BE PROTECTED FROM WATER HAMMER OR SHOCKS BY APPROVED WATER HAMMER ARRESTORS. D. VALVES SHALL BE INSTALLED ON BRANCHES AND AT SINGLE FIXTURES WHEN TRIM DOES NOT INCLUDE STOPS. PROVIDE CHICAGO MODEL NO. 1018 HEAVY DUTY STOPS OR APPROVED EQUAL. E. FINAL CONNECTIONS SHALL BE MADE TO ALL EQUIPMENT WITH PROPER CONNECTION WHETHER FURNISHED BY THIS CONTRACTOR OR BY OTHERS. THIS CONTRACTOR SHALL PROVIDE FAUCETS, TRAPS, STRAINERS AND SUPPLIES. 3.02 DRAINAGE SYSTEMS: A. THE INTERIOR DRAINAGE SYSTEMS SHALL BE CONSTRUCTED USING MATERIALS AND METHODS AS SPECIFIED AND/OR INDICATED. B. PROVIDE PROPERLY TRAPPED AND VENTED WASTE CONNECTION TO FIXTURES, FLOOR DRAINS, AND SPECIAL EQUIPMENT. C. DRAIN PIPING SHALL BE UNIFORMLY PITCHED TO CONFORM WITH STATE AND LOCAL PLUMBING CODE. D. NOT USED E. TRAPS OF MATERIAL AND DESIGN APPROVED BY THE LATEST ADDITION OF THE APPLICABLE PLUMBING CODE SHALL BE FURNISHED & INSTALLED BY THE PLUMBING CONTRACTOR FOR ALL EQUIPMENT AND APPLIANCES. ALL TRAPS SHALL HAVE THE BOTTOM CLEANOUTS WHERE ACCESS CAN BE PROVIDED. F. CAREFULLY INSPECT FOR DAMAGED MATERIALS. RUN PIPING AS SHOWN ON THE DRAWINGS, MAKE CHANGES IN DIRECTION WITH LONG SWEEP 1/8 OR 1/16 BENDS. CONNECTIONS TO STACKS MAY BE WITH SANITARY T-FITTINGS. 3.05 STERILIZATION: A. THE NEW PORTIONS OF THE POTABLE WATER DISTRIBUTION SYSTEM SHALL BE THOROUGHLY FLUSHED CLEAN, DISINFECTED AND TESTED AS PER THE STATE PLUMBING CODE. 3.06 COMPLETION: A. PROVIDE PROPERLY EXECUTED CERTIFICATE OF INSPECTION FROM THE LOCAL PLUMBING INSPECTORS OFFICE. B. VERIFY THAT PROJECT RECORD DOCUMENTS ARE COMPLETE AS SPECIFIED UNDER SUBMITTALS AND RECORD DOCUMENTS. 3.07 SCAFFOLDING, RIGGING AND HOISTING: A. PROVIDE SCA FO SCAFFOLDING, RIGGING HOISTING AND SERVICES NECESSARY FOR DELIVERY ERECTION AND INSTALLATION OF MATERIAL, EQUIPMENT AND APPARATUS FURNISHED UNDER THIS DIVISION. REMOVE SAME FROM PREMISES UPON COMPLETION OF WORK. 3.09 CUTTING AND PATCHING A. PROVIDE ALL CUTTING AN PATCHING NECESSAR T INSTALL THE WORK SPECIFIED IN THIS P E UTT D NECESSARYTO DIVISION. PATCHING SHALL MATCH ADJACENT SURFACES. B. SAW CUT, CHANNEL, CHASE, AND CORE -DRILL FLOORS, WALLS, PARTITIONS, CEILINGS, AND OTHER SURFACES T E FOR PLUMBING INSTALLATION. PERFORM CUTTING BY SKILLED E NECESSARY R 0 UM MECHANICS OF THE TRADE INVOLVED. REPAIR CUT SURFACES TO MATCH ADJACENT SURFACES. C. FIRESTOP ALLPENETRATIONS BETWEEN FLOORS &FIRE RATED WALLS. D. NO STRUCTURAL MEMBERS SHALL BE CUT WITHOUT THE APPROVAL OF THE ENGINEER, & ALL SUCH CUTTING SHALL BE ACCOMPLISHED IN A MANNER DIRECTED BY THE ENGINEER. 3.09 APPROVALS AND SUBSTITUTIONS A. IT IS THE INTENT OF THESE SPECIFICATIONS THAT WHEREVER A MANUFACTURER IS SPECIFIED AND SUBSTITUTIONS ARE ALLOWED, THEY SHALL CONFORM IN ALL RESPECTS TO THE SPECIFIED ITEM CRITERIA AS DELINEATED, SPECIFIED EQUIPMENT SHALL BE INTERPRETED AS MINIMUM PERFORMANCE REQUIREMENTS. B. SUBSTITUTED EQUIPMENT WHERE PERMITTED MUST CONFORM TO SPACE REQUIREMENTS. ANY SUBSTITUTED EQUIPMENTTHAT CANNOT MEET SPACE REQUIREMENTS, WHETHER APPROVED OR NOT, SHALL BE REPLACED AT THE CONTRACTOR' S EXPENSE, ANY MODIFICATION R ADDITIONAL COSTS THAT RESULT FROM SUBSTITUTED OF RELATED SYSTEMS 0 10 EQUIPMENT 0 E SHALL BE BORNE BY THIS CONTRACTOR. C. IT SHALL BE MANDATORY FOR THIS CONTRACTOR TO SUBMIT HIS BID PRICE BASED ON SPECIFIED MANUFACTURERS OR SUPPLIERS OF MATERIALS OR SERVICES. IF THE CONTRACTOR DESIRES TO , SUBSTITUTE OTHER THAN SPECIFIED HE SHALL SUBMIT SEPARATE PRICES FOR EACH U OF THESE ITEMS FOR ADDITIONS OR DEDUCTIONS TO THE BID PRICE, FOR ACCEPTANCE OR REJECTION AT THE TIME BIDS ARE DUE. SHOULD THESE SUBSTITUTIONS BE REJECTED, THE CONTRACTOR SHALL BE OBLIGED TO PROVIDE SPECIFIED MATERIALS AND SERVICES. 3.10 CODES, PERMITS, TESTING AND INSPECTIONS A. ALL WORK SHALL MEET OR EXCEED LATEST REQUIREMENTS OF THE STATE BUILDING & PLUMBING CODES, LOCAL CODES AND AUTHORITIES EXERCISING JURISDICTION OVER THE WORK OF THIS PROJECT. DURING THE PROGRESS OF THE WORK IT SHALL BE SUBJECT TO THE INSPECTION OF THE OWNER, CITY AGENCIES, UTILITY INSPECTORS,AND TO SUCH OTHER INSPECTORS AS MAY HAVE JURISDICTION AT THE CONTRACTOR'S COST. B. ANY PORTION OF WORK WHICH IS NOT SUBJECTTO THE APPROVAL OF AN AUTHORITY HAVING JURISDICTION SHALL BE PROVIDED IN ACCORDANCE WITH NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS. C. COMPLY WITH APPLICABLE UTILITY COMPANY RULES AND REGULATIONS. D. THE CONTRACTOR SHALL SECURE REQUIRED PERMITS INSPECTION & TEST CERTIFICATES, TRANSMIT SAME TO THE OWNER AT THE COMPLETION OF THE WORK. PAY ALL ASSOCIATED FEES. E. AT COMPLETION OF THE WORK, CONTRACTOR SHALL SUBMIT TO THE OWNER'S I WRITING ASTATEMENT STATING: 1 THAT THE WORK IS COMPLETE 2 REPRESENTATIVE N W G (} E () THAT THE ENTIRE INSTALLATION IS IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATION; 3 THAT PRELIMINARY TEST HAVE BEEN MADE; AND 4 THAT THE WORK IS READY FOR FINAL INSPECTION AND TEST, F. A FINAL INSPECTION OF THE INSTALLATION TO DETERMINE COMPLIANCE WITH THE DRAWING AND SPECIFICATIONS WILL BE MADE BY THE OWNER'S REPRESENTATIVE. WORK WILL BE CHECKEDQUALITY OF MATERIALS, QUALITY OF WORKMANSHIP PROPER INSTALLATION FOR Q AND FINISHED APPEARANCE. THIS CONTRACTOR SHALL PROVIDE THE SERVICES OF THE PROJECT FOREMAN FOR INSPECTION ION PURPOSES. S. THE FOREMAN SHALL REMOVE AND REINSTALL ACCESS SE PANELS, CEILING TILES, ETC., AS REQUIRED TO FACILITATE ANY INSPECTIONS REQUIRED BY THE OWNER'S REPRESENTATIVE. G. THE CONTRACTOR SHALL ARRANGE AND CONDUCT OPERATING TESTS ON ALL EQUIPMENT IN PRESENCE THE F OWNER'S REPRESENTATIVE. THE COMPONENT PARTS OF SYSTEMS AND ENC 0 THE 0 H THE VARIOUS SYSTEMS SHALL L M DEMONSTRATED TO OPERATE IN ACCORDANCE WITH THE L BE REQUIREMENTS AND INTENT OF THIS SPECIFICATION. ANY NON -COMPLYING OR DEFECTIVE MATERIALS OR WORKMANSHIP DISCLOSED AS A RESULT OF THE INSPECTION AND TESTS SHALL BE CORRECTED PROMPTLY BY THE CONTRACTOR, AND THE TESTS REPEATED AS OFTEN AS NECESSARY UNTIL APPROVED AND ACCEPTED BY THE OWNER'S REPRESENTATIVE. 3.11 SHOP DRAWINGS AND EQUIPMENT SUBMISSIONS A. LAYOUTS AND CERTIFIED EQUIPMENT MANUFACTURER'S DATA SHALL BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION, ERECTION OR PURCHASE. B. SHOP DRAWINGS SHALL INCLUDE BUT NOT NECESSARILY LIMITED TO: PLUMBING FIXTURES AND TRIM, PIPING, PIPE INSULATION, SHOCK ARRESTORS, VALVES, TRAP PRIMERS, WATER HEATERS, CLEANOUTS AND FLOOR DRAINS, C. CERTIFICATION SHALL BE SUBMITTED BY THE CONTRACTOR ATTESTING TO THE FACT THAT SPECIFIED PERFORMANCE CRITERIA ARE MET BY ALL EQUIPMENT. 3.12 CLEANING AND TESTS A. THE CONTRACTOR SHALL KEEP THE BUILDING AND SITE CLEAN FROM HIS OWN RUBBISH AND/OR WASTE MATERIALS AND, UPON COMPLETION OF HIS CONTRACT, SHALL LEAVE THE BUILDING, SITE AND INSTALLATION IN A CLEAN CONDITION COMPLETELY ACCEPTABLE TO THE OWNER'S REPRESENTATIVE. B. CLEAN AND TEST ALL NEW AND EXISTING PLUMBING SYSTEMS, FIXTURES AND EQUIPMENT. C. IF ANY PART OF A SYSTEM SHOULD BE STOPPED BY ANY FOREIGN MATTER AFTER BEING PLACED IN OPERATION CLEAN AND RECONNECT SYSTEM. 3.13 OPERATING AND MAINTENANCE INSTRUCTIONS A. AFTER FINAL TESTS AND ADJUSTMENTS FULLY INSTRUCT OWNER'S OPERATING PERSONNEL IN ALL DETAILS OF OPERATIONS FOR EQUIPMENT INSTALLED. A SIGNED RECEIPT WHICH SHALL BE OBTAINED FROM THE OPERATOR SHALL BE CONSTRUED AS EVIDENCE THAT INSTRUCTIONS WERE SATISFACTORY. B. FURNISH THREE (3) COPIES OF WRITTEN DESCRIPTIONS OF ALL SYSTEMS COVERING ALL MANUAL OPERATING PROCEDURES, AUTOMATIC CONTROL DESCRIPTIONS AND AUTOMATIC TEMPERATURE & PRESSURE SETTINGS WRITTEN DESCRIPTIONS SHALL INCLUDE LUBRICATION SCHEDULES, PARTS LIST, PERFORMANCE SERVICES FOR EQUIPMENT, FILTER SIZE/QUANTITY SCHEDULE, ETC. WHEN MANUFACTURER STANDARD INSTRUCTIONS ARE UTILIZED, THEY SHALL BE CLEARLY MARKED AS TO INDICATED APPLICABILITY. EPLUMBINGN ACTO HA L FURNISH THE FOLLOWING: C. AT THE END OF THE PROJECT, THE CONTRACTOR R SHALL APPROVED OPERATING INSTRUCTIONS FOR EACH PRINCIPAL ITEM OF EQUIPMENT FOR THE USE OF THE OPERATION AND MAINTENANCE PERSONNEL. THE OPERATING INSTRUCTIONS SHALL INCLUDE WIRING DIAGRAMS, CONTROL DIAGRAMS, AND CONTROL SEQUENCE FOR EACH PRINCIPAL ITEM OF EQUIPMENT. OPERATING INSTRUCTIONS SHALL BE PRINTED OR ENGRAVED, AND SHALL BE FRAMED UNDER GLASS OR IN AN APPROVED LAMINATED PLASTIC & POSTED WHERE DIRECTED BY ENGINEER. OPERATING INSTRUCTIONS SHALL BE ATTACHED TO OR POSTED ADJACENTTO EACH PRINCIPAL ITEM OF EQUIPMENT. INCLUDE START UP, PROPER ADJUSTMENT, OPERATING, LUBRICATION, SHUT -DOWN, SAFETY -PRECAUTIONS, PROCEDURE IN THE EVENT OF EQUIPMENT FAILURE, AND OTHER ITEMS OF EQUIPMENT. OPERATING INSTRUCTIONS EXPOSED TO THE WEATHER SHALL BE WEATHER PROTECTED. OPERATING INSTRUCTIONS SHALL NOT FADE WHEN EXPOSED TO SUNLIGHT & SHALL BE SECURED TO PREVENT REMOVAL OR PEELING. D. PROVIDE VALVE TAGS & CHARTS. 3.14 GUARANTEES A. EXCEPT AS OTHERWISE SPECIFIED, ALL WORK SHALL BE GUARANTEED TO BE FREE FROM LEAKS OR OTHER DEFECTS RESULTING FROM THE USE OF INFERIOR MATERIALS, EQUIPMENT, OR DAMAGES TO HE WORKMANSHIP, ALL DEFECTIVE MATERIAL OR WORKMANSHIPAS WELL AS G T WORK OF ALL TRADES RESULTING FROM SAME SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. B. THE GUARANTEE PERIOD SHALL BE FOR ONE (1) YEAR FORM THE DATE OF ACCEPTANCE, WHICH SHALL BE THE DATE OF FINAL PAYMENT OR THE DATE OF FORMAL NOTICE OF ACCEPTANCE, WHICHEVER IS EARLIER. C. CERTIFICATION SHALL BE SUBMITTED BY THE CONTRACTOR ATTESTING TO THE FACT THAT SPECIFIED PERFORMANCE CRITERIA ARE MET BY ALL EQUIPMENT. D. IF, WITHIN ANY GUARANTEE PERIOD, REPAIRS OR CHANGES TO GUARANTEED WORK ARE REQUIRED AS A RESULT OF THE USE OF DEFECTIVE MATERIALS OR EQUIPMENT, INFERIOR WORKMANSHIP OR WORK THAT IS NOT IN ACCORDANCE WITH THE TERMS OF THE CONTRACT, AND UPON RECEIPT OF NOTICE FROM THE OWNER, THE FOLLOWING SHALL BE DONE WITHOUT EXPENSE TO THE OWNER: a. REPAIR ALL DAMAGE TO THE BUILDING OR SITE/EQUIPMENT OR CONTENTS THEREOF WHICH IS THE RESULT OF THE USE OF DEFECTIVE MATERIALS OR EQUIPMENT OR INFERIOR WORKMANSHIP, OR OF WORK NOT IN ACCORDANCE WITH THE TERMS OF THE CONTRACT. b. MAKE GOOD ANY WORK OR MATERIALS, OR THE EQUIPMENT AND CONTENTS OF SAID BUILDING OR SITE DISTURBED IN FULFILLING ANY SUCH GUARANTEE. E. IN FULFILLING THE REQUIREMENTS OF THE CONTRACT OR OF ANY GUARANTEE EMBRACED IN OR REQUIRED THEREBY, ANY WORK GUARANTEED UNDER ANOTHER CONTRACT IS DISTURBED, RESTORE SUCH DISTURBED WORK TO ORIGINAL CONDITION AND GUARANTEE SUCH RESTORED WORK TO THE SAME EXTENT AS IT WAS GUARANTEED UNDER SUCH OTHER CONTRACT. F. IF UPON FAILURE TO PROCEED PROMPTLY AFTER NOTICE TO COMPLY WITH THE TERMS OF THE GUARANTEE, THE OWNER MAY HAVE DEFECTS CORRECTED AND CONTRACTOR AND HIS SURETY SHALL BE LIABLE FOR ALL EXPENSES INCURRED. 3.15 AS -BUILT DRAWINGS A. AS BUILT DRAWINGS, INDICATING ALL MODIFICATIONS RELATIVE TO CONTRACT DRAWINGS DURING THE PROGRESS OF THE WORK SHALL MAINTAIN AN ACCURATE RECORD OF ALL U G L CHANGES MADE IN THE PLUMBING SYSTEMS. THE AS BUILT DRAWINGS SHALL INCLUDE CHANGES IN MANUFACTURERS (WITH MODEL NUMBERS AND TRADE NAMES). MATERIALS, SIZES, LOCATIONS AND HOOK-UP POINTS. AS-BUILTS SHALL BE GIVEN TO OWNER'S REPRESENTATIVE AT COMPLETION OF WORK -ONE (1) REPRODUCIBLE (SEPIA) AND THREE (3) COPIES OF PRINTS. 3.16 ELECTRICAL WORK A. ELECTRICAL COMPONENTS OF PLUMBING EQUIPMENT AND SYSTEMS, SUCH AS MOTORS, FACTORY MOUNTED STARTERS, FACTORY MOUNTED DISCONNECTS AND CONTROL EQUIPMENT SHALL BE PROVIDED BYTHE PLUMBING CONTRACTOR. B. TEMPERATURE CONTROL EQUIPMENT, INCLUDING AQUASTATS, ETC. SHALL BE FURNISHED BY THE PLUMBING CONTRACTOR, TEMPERATURE CONTROL WIRING NOT SPECIFICALLY SHOWN ON ELECTRICAL DRAWINGS SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR. AUTOMATIC CONTROL CONTRACTOR SHALL OBTAIN HIS REQUIRED POWER FROM NEAREST SPARE BREAKERS, PROVIDE POWER TRANSFORMATION IF REQUIRED, AND ALL SYSTEM LOW VOLTAGE AND/OR LINE VOLTAGE WIRING. C. RELAYS AND WIRING REQUIRED FOR INTERLOCKING SYSTEMS SHALL BE FURNISHED AND INSTALLED BY THE PLUMBING CONTRACTOR. POWER WIRING SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 3.17 SAFETY A. COMPLY WITH ALL OF THE SAFETY REQUIREMENTS OF OSHA THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD OF THE PROJECT. B. FURNISH, PLACE AND MAINTAIN PROPER GUARDS FOR PREVENTION OF ACCIDENTS AND ANY OTHER NECESSARY CONSTRUCTION REQUIRED TO SECURE SAFETY OF LIFE AND/OR PROPERTY 3.18 REMOVAL AND ALTERATIONS A. THE CONTRACTOR SHALL REMOVE, RELOCATE, REPLACE, ADJUST, ADAPT AND MODIFY EXISTING FIXTURES AND/OR SYSTEMS AS REQUIRED BY THE DRAWINGS OR SPECIFICATIONS AND AS MAY BE REQUIRED WHEN SUCH WORK IS UNCOVERED AND FOUND TO INTERFERE WITH THE COMPLETION OF WORK IN THIS CONTRACT OR OTHER CONTRACT WORK. REMOVED ITEMS SHALL BE STORED IN A PLACE DESIGNATED D BY THE OWNER. IF HOWEVER THE OWNER DOES E NOT DESIRE TO RETAIN POSSESSION OF REMOVED ITEMS, THEY SHALL BECOME THE PROPERTY OF THE CONTRACTOR WHO SHALL REMOVE THEM FROM THE PROJECT SITE AND DISPOSE OF THEM IN A LEGAL MANNER. GENERAL NOTES: 1. ALL PLUMBING ROUGHING AND MOUNTING HEIGHTS ARE TO BE IN STRICT ACCORDANCE WITH LOCAL CODES. THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH FOOD SERVICE EQUIPMENT ROUGH -IN DRAWINGS AND ARCHITECTURAL DRAWINGS, AS WELL AS CONTRACTORS OF ALL OTHER TRADES, PRIOR TO INSTALLATION. 2. PIPE ROUTING SHOWN IS SCHEMATIC AND IS NOT INTENDED TO INDICATE EXACT ROUTING OR LOCATION OF PIPING. ANY ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN PROPER CLEARANCES, SHALL BE PROVIDED AND INSTALLED BY THIS CONTRACTOR. THIS CONTRACTOR SHALL PROVIDE ACCESSIBLE SANITARY CLEANOUTS AND ALL SANITARY SYSTEM VENTING AND FITTINGS AS PER LOCAL AND STATE REQUIREMENTS. 3. THIS CONTRACTOR SHALL PROVIDE AND INSTALL ALL APPURTENANCES REQUIRED TO PLACE ALL FIXTURES AND EQUIPMENT IN FULL OPERATIONAL CONDITION. APPURTENANCES INCLUDE, BUT ARE NOT LIMITED TO, SHUT-OFF VALVES, FLEXIBLE RISERS, ANGLE STOPS, VACUUM BREAKERS, ESCUTCHEONS, PIPE SLEEVES, PRV'S, BACKFLOW PREVENTERS, TEMPERATURE AND PRESSURE GAUGES, T & P RELIEF VALVES, UNIONS, FLEXIBLE GAS CONNECTIONS, GAS REGULATORS, GAS COCKS, CLEANOUTS, ETC. 4. ALL EXPOSED PIPING SHALL BE PAINTED TO MATCH THE APPROVAL OF THE ARCHITECT'S CRITERIA. INSTALL WATER SHOCK ARRESTORS AT EACH FIXTURE OR BATTERY OF FIXTURES. ALL INDIRECT WASTE PIPING SHALL BE COPPER AND CHROME PLATED BRASS WHERE EXPOSED. 5. THIS CONTRACTOR SHALL OBTAIN DIMENSIONED ROUGHING DRAWINGS FROM EQUIPMENT SUPPLIER PRIOR TO WORK COMMENCING. 6. THIS CONTRACTOR SHALL FLASH ALL FLOOR DRAINS WATERTIGHT. 7. NEW 2" FLOOR DRAIN W/ ST. ST. STRAINER "P" TRAP ASSEMBLY, 2" VP UP FOR NEW ADA SHOWER DRAIN. CUT SLAB ABOVE AND CONNECT INTO EXISTING SANITARY LINES BELOW FLOOR SLAB. THIS CONTRACTOR TO FIELD VERIFY ONCE SLAB IS CUT AND CONNECT INTO THE EXISTING BATHROOM GROUPS SANITARY BRANCH MAIN IN THE PROPER DIRECTION OF FLOW AND CONNECTION REQUIREMENTS. FRENCO'S CAN NOT BE USED BELOW THE FLOOR SLAB, FITTINGS MUST BE USED. 8. NEW 2" FLOOR DRAIN WITH ST. ST. STRAINER "P" TRAP ASSEMBLY, 2" VP UP FOR NEW ADA SHOWER DRAIN. THIS CONTRACTOR TO VERIFY EXACT LOCATION AND INV, ELEVATION IN THE FIELD - TYP. GENERAL PLUMBING NOTES 1. CONTRACTORS SHALL VISITTHE PROJECT PRIOR TO SUBMITTAL OF PROPOSAL AND THOROUGHLY FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND CONDITIONS THAT WILL AFFECT THE PERFORMANCE OF THEIR WORK. ANY DISCREPANCIES OR QUESTIONS REGARDING THE ABOVE SHALL BE SUBMITTED IN WRITING TO THE ENGINEER PRIOR TO BIDDING FOR CLARIFICATION. FAILURE TO DO SO WILL NOT ENTITLE THEM TO ANY ADDITIONAL COMPENSATION FOR PROVIDING A COMPLETE AND APPROVED SYSTEM. 2. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING ALL FINAL PLUMBING CONNECTIONS TO EQUIPMENT SUPPLIED UNDER OTHER SECTIONS OF SPECIFICATIONS OR SUPPLIED BY THE OWNER. THE PLUMBING CONTRACTOR SHALL ALSO PROVIDE ALL INDIRECT WASTES FROM THE ABOVE MENTIONED EQUIPMENT TO FD'S. REFER TO EQUIPMENT DRAWINGS FOR SPECIFIC REQUIREMENTS INCLUDING ROUGH -IN LOCATIONS AND SIZES. 3. FIRESTOP ALL PENETRATIONS BETWEEN FLOORS & FIRE RATED WALLS WITH APPROVED FIRE STOPPING ASSEMBLIES AS MANUFACTURED BY 3M INDUSTRY, HILT[ OR APPROVED EQUAL. THE ASSEMBLIES SHALL COMPLY WITH THE LATEST APPLICABLE REQUIREMENTS OF THE: BUILDING CODE, NFPA STANDARDS AND OWNERS INSURANCE COMPANY. PROPOSED APPLICABLE ASSEMBLIES SHALL BE UL LISTED AND SHALL BE PART OF THE PLUMBING EQUIPMENT SUBMITTAL. 4. BEFORE COMMENCEMENT OF WORK OR ORDERING FIXTURES OR OTHER EQUIPMENT, THIS CONTRACTOR SHALL: a. VERIFY EXACT LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF EXISTING UTILITIES AND PIPING. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. b. COORDINATE INDICATED WORK WITH THE WORK AND CONTRACTORS OF ALL OTHER TRADES, PRIOR TO INSTALLATION. c. REVIEW ALL ARCHITECTURAL PLANS AND ENLARGED PLANS AND ELEVATIONS BEFORE ANY ROUGHING WORK OR PLUMBING WORK IS STARTED. d. PROVIDE AND INSTALL ALL PLUMBING WORK INDICATED ON PLUMBING, AND ARCHITECTURAL DRAWINGS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF PLUMBING FIXTURES, 5, DO NOT SCALE THESE DWGS. REVIEW ARCHITECTURAL DRAWINGS FOR ROOM TYPES, I BEFORE BIDDING AND PLUMBING WORK I LOCATIONS NOTES AND DIMENSIONS BE 0 D U S STARTED. QUESTIONS REGARDING DI E D IN WRITING TO THE ENGINEER PRIOR THE ABOVE SHALL BE SUBMITT E TO BIDDING FOR CLARIFICATION. FAILURE TO DO SO WILL NOT ENTITLE THEM TO ANY ADDITIONAL COMPENSATION FOR PROVIDING A COMPLETE AND APPROVED SYSTEM. 6. PIPE ROUTING SHOWN IS SCHEMATIC AND IS NOT INTENDED TO INDICATE EXACT ROUTING OR LOCATION OF PIPING. ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN PROPER CLEARANCES SHALL BE AND INSTALLED BY THIS CONTRACTOR, STRUCTURAL MEMBERS SHALL NOT BE COMPROMISED. OFFSET PIPING AS REQUIRED TO AVOID EXISTING FIXED EQUIPMENT, PIPING & STRUCTURAL MEMBERS. DO NOT RUN IN OR THRU ELECTRICAL ROOMS AND ELEVATOR MACHINE ROOMS. ALL PIPING SHALL BE CONCEALED INSIDE WALLS, BELOW FLOORS, OR ABOVE CEILINGS UNLESS INDICATED OTHERWISE. ALL PIPES DROPPING AT COLUMNS SHALL BE INSTALLED WITHIN THE COLUMN ENCLOSURE SUCH THAT DIMENSIONS TO THE ENCLOSURE ARE NOT ALTERED. 7. NOT USED. 8. REFER TO ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE LOCATIONS AND MOUNTING HEIGHTS THAT SHALL BE IN STRICT ACCORDANCE WITH STATE CODES AND ADA REQUIREMENTS. THIS CONTRACTOR SHALL COORDINATE WORK INDICATED ON PLUMBING DRAWINGS WORK WITH ARCHITECTURAL DRAWINGS AS WELL AS FIELD CONDITIONS PRIOR TO INSTALLATION. FINAL LOCATION SHALL BE AS DIRECTED BY ARCHITECT. 9. THE FIXTURE ROUGH -INS SHOWN ARE ACCURATE TO THE BEST AVAILABLE INFORMATION. HOWEVER, IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN. THEREFORE THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT ACTION DIRECTLY UPON THE CONTRACTOR. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TRENCHES, COMPACTING, AND BACKFILLING FOR ALL UNDERSLAB PIPING. COORDINATE ALL UNDERGROUND PIPING WITH GRADE BEAMS, WALL FOOTINGS AND OTHER STRUCTURAL CONDITIONS. SET SLEEVES IN FLOORS AND WALLS AND ATTACHMENTS FOR HANGERS AS CONSTRUCTION PROGRESSES. ALL PENETRATIONS MUST BE SEALED AND HELD TIGHT TO COLUMNS OR WALLS AS POSSIBLE. 11. THIS CONTRACTOR SHALL LOCATE VALVES, SHOCK ARRESTORS AND TRAPS IN ACCESSIBLE LOCATIONS. PROVIDE 12"x12" ACCESS PANELS WITH HINGED DOORS AND RATED WHERE REQUIRED (INCLUDING AT EXISTING VALVES ABOVE CEILINGS). FINAL LOCATIONS OF ACCESS PANELS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. CONTRACTOR SHALL PROVIDE ACCESS PANELS IN SOLID & NON -REMOVABLE CEILINGS, WALLS AND ANY OTHER ENCLOSURES TO PROVIDE ACCESS TO BALANCING VALVES AND SHUT-OFF VALVES. SELECTION OF ACCESS PANEL TYPE, COLOR ETC. SHALL MATCH THAT OF SURROUNDING CEILING, WALL OR ENCLOSURE. 12. THIS CONTRACTOR SHALL PROVIDE ALL PIPING, APPURTENANCES & FINAL CONNECTIONS REQUIRED TO LEAVE ALL EXISTING AND NEW PLUMBING SYSTEMS IN A SAFE AND OPERATIONAL CONDITION AT THE COMPLETION OF THE PROJECT. APPURTENANCES INCLUDE, BUT ARE NOT LIMITED TO: SHUT-OFF VALVES, FLEXIBLE RISERS, ANGLE STOPS, VACUUM BREAKERS, ESCUTCHEONS, TRAPS, PIPE SLEEVES, CLEANOUTS ETC. 13. EXACT LOCATION OF ALL NEW FLOOR AND WALL OPENINGS SHALL BE DETERMINED IN FIELD PER EXISTING CONDITIONS AND COORDINATED WITH ALL TRADES. 14. SLOPE DRAINAGE PIPING 1/8" PER FOOT UNLESS OTHERWISE NOTED. 15. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND INSPECTIONS. PROVIDE INSURANCE CERTIFICATES AS MAY BE REQUIRED BY THE CONSTRUCTION MANAGER AND OWNER. 16. LOCATE ALL HOSE BIBBS V-0" ABOVE FLOOR IN TOILET ROOMS. INSTALL (1) CHROME PLATED HOSE BIBB WITH VACUUM BREAKER AND LOOSE KEY OPERATION UNDER LAVATORY IN TOILET ROOMS EQUIPPED WITH FLOOR DRAINS. LOCATE EXTERIOR WALL HYDRANTS 3'-0" MINIMUM ABOVE GRADE AND AS PER CODE. 17. SIZES OF CONCRETE BASES OR PADS OF ALL EQUIPMENT SHALL BE COORDINATED DURING APPROVAL OF SHOP DRAWINGS. 18. SECTIONALIZING VALVES FOR ALL PUMPS, HEATERS, PLUMBING EQUIPMENT, AND BRANCH PIPING SHALL BE PROVIDED. PROVIDE A VALVED BYPASS AT ALL EQUIPMENT INCLUDING WATER HEATERS FOR MAINTENANCE OF EQUIPMENT. 19. LOCATE ALL EQUIPMENT WHICH MUST BE SERVICED, OPERATED, ADJUSTED OR MAINTAINED IN FULLY ACCESSIBLE POSITIONS. 20. ALL PIPING AND EQUIPMENT SHALL BE PROPERLY SUPPORTED FROM STRUCTURE. PROVIDE SUPPLEMENTARY STEEL AND SUPPORTS AS REQUIRED OR DIRECTED. 21. LOCATE PIPING AND EQUIPMENT TO CLEAR ALL SERVICES. LOCATE ALL PIPING AS CLOSE AS QU I POSSIBLE TO STEEL FRAMING UNLESS OTHERWISE NOTED. 22. DO NOT RUN PLUMBING PIPING THROUGH TRANSFORMER VAULTS, ELECTRICAL SWITCHGEAR ROOMS, ELECTRICAL ROOMS OR TELEPHONE ROOMS. 23. PROVIDE CLEANOUTS ON DRAINAGE PIPING AT: ALL CHANGES IN DIRECTION, BASE OF STACKS, WHERE INDICATED AND AS PER PLUMBING CODE. LOCATE CLEANOUTS IN ACCESSIBLE LOCATIONS. 24. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING VENTS THRU ROOFS. ALL ROOFING WORK REQUIRED TO INSTALL NEW ROOF MOUNTED EQUIPMENT OR TO MAKE PENETRATIONS THROUGH THE ROOF SHALL BE PROVIDED BY THIS CONTRACTOR AND SHALL BE ACCOMPLISHED BY A ROOFING SUB -CONTRACTOR APPROVED BY THE MANUFACTURER OF THE EXISTING ROOFING, SO AS TO MAINTAIN THE EXISTING ROOF WARRANTY. 25. CONTRACTOR SHALL EXERCISE EXTREME CARE WHILE CUTTING WALL OR FLOOR SLAB NOT TO DAMAGE EXISTING UTILITIES WHICH ARE TO REMAIN. 26. UTILITY SHUTDOWNS AND REMOVALS SHALL BE COORDINATED WITH THE LANDLORD & OWNERS REPRESENTATIVE AND SHALL BE ACCOMPLISHED AT A TIME CONVENIENTTO THEM. 27. TRIP LEVERS FOR NEW HANDICAPPED WATER CLOSETS SHALL BE INSTALLED FACING WIDER SECTION OF HANDICAPPED STALL AS PER A.D.A. REGULATIONS. 00 ,It O O i N N 1 EL- U w �_- 0 N w PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 M O 0 N U o � ¢ U W i�iW r- _3�: O� V _1 ce U ceo O m W 3: x3 O� 0 , 10 v o T u M 1 - N � w LO r_ L0 r f = CD �/ V� J 0 F- � zui . w LL. u N v) N z JT . F_ I. y r- L WLu N V °O CV � ('') C) a - t, , 7!!5v Ci ,* o 0 a U U � (0-, O M■■� M.01 E� 0 r.(5r,o0 W) 0 • po E„i M M cl M M � U c1 (=�) O N M O M • Io � tjDtfi tn O N 0 0o0 00 O U 0 U rA 0 un j U 'd .s c�., 4 [�� -4111� I O C)4N �1 P-� M 00 STAMP: "'*j-o**04 #y60# t- 4-j - �/r 0 r *, , r W, ,N I �, o r � { s � .� j :. y j' . :.. a 1 F ," f . ',�. r , C � - air. ,. ar� t. t;�04i 111 +'.iiF ,t ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: LRV CHECKED BY: FZ DRAWING TITLE: PLUMBING - SPECIFICATIONS DRAWING NUMBER: P200 f� MECHANICAL SYMBOL LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT GENERAL PIPING ABBREVIATIONS PROJECT GENERAL NOTES ' EQUIPMENT TO BE REMOVED (DC COOLING THERMOSTAT (REVERSE ACTING) HWS HEATING HOT WATER SUPPLY AFF ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT ABOVE FINISHED FLOOR HVAC HEATING, VENTILATION, AND AIR CONDITIONING 1. SCOPE OF WORK SHALL INCLUDE ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, TRANSPORTATION, HOISTING, RIGGING, INSURANCE, ETC., TO PERFORM THE WORK AS —HWR— —HEATING HOT WATER RETURN INDICATED ON THE DRAWINGS AND HEREIN SPECIFIED FOR A COMPLETE PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 " O o N V W QU w � uO� r �V W°� O� �� M �O O � � N � u w u� v J 0 u ww � z w N � N z �/ � �- Z N W W U 00 N � Q � o M O C� � o U � N OMM •^�' �j Q O � 00 � O U O 4N M 00 STAMP: *fit y w r w ISSUE: DATE: ISSUED FOR PERMIT O1 /25/2023 DRAWING SCALE: NOTED DRAWN BY: MP CHECKED BY: FZ DRAWING TITLE: MECHANICAL -LEGENDS &SYMBOLS DRAWING NUMBER: moo IV 00 O O N N A-� E-i W ti tx W N w INSTALLATION. Laf 0 U- Lo L AND OPERATION Lin 0 PEA 0 I ZV ZONE VALVE F BLADE 07 4w c KEYED SHEET NOTES <^1 EXISTING EXHAUST FAN TO REMAIN EXISTING AIR HANDLING UNIT TO REMAIN �<,>EXISTING CEILING MOUNTED ELECTRIC AIR CLEANER TO REMAIN 4 < >' EXISTING DIFFUSER TO BE RELOCATED GENERAL SHEET NOTES 1. EXISTING CONDITIONS ARE SHOWN VIA SITE VISIT AS BEST POSSIBLE. CONTRACTOR TO NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES THAT WILL IMPACT SCOPE IF DISCOVERED. 2. CONTRACTOR SHALL VISIT THE SPACE PRIOR TO BIDDING AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND SCOPE. 3. THE INTENT OF THIS PROJECT IS FOR THE EXISTING HVAC SYSTEMS TO REMAIN IN PLACE AND RELOCATED EXISTING DIFFUSERS AND GRILLES AS NEEDED FOR THE NEW LAYOUTS. 4. ALL DIFFUSERS ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE u u u u u u U U U U MECHANICAL DEMOLITION EXISTING CONDENSING UNITS 1 SCALE.1/8 —1-0 EXISTING CONDENSING UNITS TO REMAIN (TYPICAL.) TO REMAIN (TYPICAL.) 0 s 0 16-0 24-0 PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 cn "' 0 o NV oU Lu Q w uu DQ � 0 _.J O V W m3: x3�: 03 0 M 10 u ,� O rl N w �n �_ Lo r n Ln 00 vn 00 v I O w w u- zu� N n CV J Q � Z � r W ZN W U Q o < CN°Od � cy) — ¢� U .N V1 0 r oMo ��11 '5 M M V N ) rn opo000 ci a � 00 STAMP: i W� * i , 4 lyGy,{ it y ,war, 41~�ir1i4'�� �t�•. ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: MP CHECKED BY: FZ DRAWING TITLE: MECHANICAL - DEMOLITION DRAWING NUMBER: MD1 00 KEYED SHEET NOTES <�1 > EXISTING EXHAUST FAN TO REMAIN EXISTING AIR HANDLING UNITTO REMAIN OEXISTING CEILING MOUNTED ELECTRIC AIR CLEANER TO REMAIN C 4 > RELOCATED DIFFUSER. RECONNECT TO EXISTING BRANCH DUCTWORK II i I I�I AND CONDENSING UNIT I I I TO REMAIN EXISTING CONDENSING UNITS EXISTING CONDENSING UNITS TO REMAIN (TYPICAL.) TO REMAIN (TYPICAL.) MECHANICAL NEW WORK SCALE:1/8" = V-0" 0 8'-0" 16'-0" 24'-0" GENERAL SHEET NOTES 1. EXISTING CONDITIONS ARE SHOWN VIA SITE VISIT AS BEST POSSIBLE. CONTRACTOR TO NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES THAT WILL IMPACT SCOPE IF DISCOVERED. 2. CONTRACTOR SHALL VISIT THE SPACE PRIOR TO BIDDING AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND SCOPE. 3. THE INTENT OF THIS PROJECT IS FOR THE EXISTING HVAC SYSTEMS TO REMAIN IN PLACE AND RELOCATED EXISTING DIFFUSERS AND GRILLES AS NEEDED FOR THE NEW LAYOUTS. 4. ALL DIFFUSERS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED. EE3 • • M PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 ...J y J 0 0 M O O N U <U u.i U F- S = UD < Q OV � 0 m w3 0 x3�: 03 uM �O o� N 'T w �n Lo rn V) � 01) v I Ln ww Z w. � u 04 N N CV F— 7 ry Z W Z. w U °O N � QCD co . J/ t0, U O 00N .� � M M O C) n M O v O U 7D .� N a M 00 STAMP: i r 4 i 1 • 4 . r } ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: MP CHECKED BY: FZ DRAWING TITLE: MECHANICAL - NEW WORK PLAN DRAWING NUMBER: mi'so I Y � i I - F 11111 SUPPORT FROM UNDERSIDE OF STRUCTURE (TYP) _�l HARD DUCT INSULATION TRANSITION AS REQUIRE ,w-, / \ `-� DUCT INSULATION MAXIMUM SAG 1/2" PER FOOT CEILING NOTE: 1. THIS CONFIGURATION TO BE USED ONLY WHEN SPACE RESTRAINTS WILL NOT ALLOW USE OF THE DIFFUSER BOOT. SUPPORT FROM UNDERSIDE OF STRUCTURE (TYP) — DIFFUSER BOOT OR LINEAR PLENUM BOX DUCT INSULATION MAXIMUM SAG 1/2" PER FOOT CEILING 01 DUCTWORK DIFFUSER/GRILLE CONNECTION DETAIL SUPPORT FROM UNDERSIDE OF STRUCTURE (TYP.) —,� HARD ELBOW DUCT INSULATION TRANSITION AS REQUIRED NO TURNS OR BENDS WILL BE 2'-0" 2'-0" 2'-0" ACCEPTABLE ON FLEXIBLE MAX MAX MAX DUCTWORK. FLEX DUCTWORK SHALL ONLY BE USED FOR STRAIGHT RUNS Lf 6-0" MAX DUCT INSULATION MAXIMUM SAG 1/2" PER FOOT. \--INSULATED FLEXIBLE DUCTWORK USE AS REQUIRED FOR DIFFUSER ALIGNMENT t---=--I--'--i-�----tom CEILING NOTES: 1. THIS CONFIGURATION TO BE USED ONLY WHEN SPACE RESTRAINTS WILL NOT ALLOW USE OF DIFFUSER BOOT. 2. NO FLEX DUCT SHALL BE USED ABOVE HARD CEILINGS OR FOR CLEAN ROOMS. 3. ALL FLEXIBLE DUCT CONNECTIONS SHALL BE BAND CLAMPED, SCREWED AND TAPED TO SOLID DUCT TO SEAL. O3 FLEXIBLE DUCTWORK DIFFUSER CONNECTION DETAIL NOT TO SCALE ROOF/FLOOR 1" ACC SOUNI ELEVATION PLAN NOTE: 1. AIR TRANSFER DUCT SHALL BE BASED UPON MAXIMUM DUCT VELOCITY OF 500 FPM O � TRANSFER AIR DUCT DETAIL � AHU EXISTING AIR HANDLING UNIT SCHEDULE (TO REMAIN) MAKE DATE OF DESIGN OUTDOOR IEER/ COOLING PERFORMANCE DATA HEATING PERFORMANCE DATA ELECTRICAL DATA UNIT NO. MANUFACTURE AIRFLOW AIRFLOW EER NOTES REFRIGERANT GROSS NET 1st STAGE 2nd STAGE 1st STAGE 2nd STAGE TEMPERATURE V/PH/HZ FLA MOP MODEL NUMBER SERIAL# (IF KNOWN) (CFM) (CFM) SEER TYPE CAPACITY MBH CAPACITY MBH INPUT MBH INPUT MBH OUTPUT MBH OUTPUT MBH RISE AHU-1 TRANE TWE18OE300AA DEC 2009 9501UY9HD 7200 R410A 180 208/3 12 20 1-6 AHU-2 TRANE TWE180E300AA DEC 2009 95C2W89HD 7200 R410A 180 208/3 12 20 1-6 AHU-1 TRANE TWE18OE300AA AUG 2013 133425MOWA 7200 R410A 180 208/3 12 20 1-6 NOTES: 1. RE -COMMISSION EXISTING UNITS TO ENSURE FULL OPERATION AND REPLACE FILTERS IF POSSIBLE OR ADVISED BY OWNER. 2. ASSOCIATED CONDENSING UNITS ARE LOCATED ON GRADE ADJACENT TO BUILDING. DIFFUSER/GRILLE/REGISTER SCHEDULE 5-00 <--TAG <-CFM SUPPLY DIFFUSERS SIZE 000 OxO MAKE ANGLE OF MOUNTING TAG ACCESSORIES SYMBOL NOTES MODEL NUMBER AIR DEFLECTION SURFACE TITUS PROVIDE ROUND ADAPTER TO S 1 2024 OMNI 360' HORIZONTAL CEILING GRID MATCH DUCT SIZE AS SHOWN 1-2 00 <-----TAG 000 �--CFM RETURN DIFFUSERS Ox0 <--SIZE MAKE MOUNTING TAG ACCESSORIES SYMBOL NOTES MODEL NUMBER SURFACE PROVIDE SQUARE TO ROUND R 1 TITUS CEILING GRID ADAPTER FOR DUCT 1 2 50E-NT CONNECTION AS SPECIFIED NOTES: 1. WHERE RETURN AIR DUCTS AND PLENUMS ARE FULL SIZE OPEN IN CEILING SPACES, PROVIDE Ya" MESH SCREENS IN AIR STREAM PRIOR TO FILTERS. 2. COORDINATE ALL TRIM STYLE, FINISH, AND COLOR WITH ARCHITECT. PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 c� ` O o N U o F- W QU uD� 0 U ck:o ° W� x� O0. LL. ,O M O UN � � LuL� F___ 00 �•/ = V) 00 J 0 vo LL, . w z Lu � N ) N Q N z Jr w ZCN w V CO N LO M Q . o U O I c� O M • M M N �Poo `0 oMM 0000 O O �+ a M 00 STAMP: ��t+�Nr�i#rfr�/rrr �r rya w A it . +' y _±'1 I, ISSUE: DATE: ISSUED FOR PERMIT 01/25/2023 DRAWING SCALE: NOTED DRAWN BY: MP CHECKED BY: FZ DRAWING TITLE: MECHANICAL - SCHEDULES DRAWING NUMBER: M260 MECHANICAL SPECIFICATIONS PINCHASERS EAST PASCO O O N N �i E-a C� r� N w PIPLU -3: 0 E KNIVELn S PIPINGcd 00 : INTERNA00 cd L PROJECT CLOSE-OU41 T: EQUIPMENT00 30 - ABBREVIATIONS ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT A/AMP AMPERE AC ALTERNATING CURRENT ADA AMERICAN WITH DISABILITIES ACT AF AMPERE FRAME AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM AT AMPERE TRIP ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE AV AUDIO VISUAL BFG BELOW FINISHED GRADE BOF BOTTOM OF FIXTURE C CONDUIT CA CABLE CAT CATALOG CATV CABLE TELEVISION CB CIRCUIT BREAKER CBA COLOR BY ARCHITECT CD CANDELA CKT CIRCUITS CU COPPER dB DECIBEL DC DIRECT CURRENT DN DOWN DWG DRAWING EC ELECTRICAL CONTRACTOR ETR EXISTING TO REMAIN F FAHRENHEIT FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FBA FINISH BY ARCHITECT FLA FULL LOAD AMPERES G GROUND GEC GROUNDING ELECTRODE CONDUCTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND HP HORSEPOWER HVAC HEATING, VENTILATION, AND AIR CONDITIONING IG ISOLATED GROUND KVA KILOVOLT -AMPERE LIGHTING FIXTURE INDICATES HOMER KW KILOWATT KWH KILOWATT HOURS LTG LIGHTING LV LOW VOLTAGE MAX MAXIMUM MCB MAIN CIRCUIT BREAKER MIN MINIMUM MLO MAIN LUG ONLY MTD MOUNTED MTG MOUNTING N NEUTRAL NA NOT APPLICABLE NEC NATIONAL ELECTRICAL CODE NL NIGHT LIGHT NIC NOT IN CONTRACT NTS NOT TO SCALE OPD OVER CURRENT PROTECTION DEVICE P POLE PH PHASE PVC POLYVINYL CHLORIDE PWR POWER RGS RIGID GALVANIZED STEEL RMS ROOT MEAN SQUARE VALUE RPM REVOLUTIONS PER MINUTE SWBD SWITCHBOARD TTB TELEPHONE TERMINAL BOARD TEL TELEPHONE TML TERMINAL TVSS TRANSIENT VOLTAGE SURGE SUPPRESSER TYP TYPICAL UG UNDERGROUND UL UNDERWRITERS LABORATORIES UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS VA VOLT-AMPERE VO TELEPHONE VFD VARIABLE FREQUENCY DRIVE VSD VARIABLE SPEED DRIVE W WATTS W/ WITH WP WEATHERPROOF XFMR/TTRANSFORMER CIRCUITING LEGEND LIGHTING FIXTURE TYPE, REFER TO LIGHTING FIXTURE SCHEDULE INDICATES CIRCUIT NUMBER ON FIXTURES MATCHING ASSOCIATED 3b �_HOMERUN INDICATES SWITCH CONTROL LA-3 INDICATES PANEL FROM WHERE BRANCH CIRCUIT ORIGINATES CIRCUIT NUMBER 3 ELECTRICAL DEVICE 48"] -MOUNTING HEIGHT A.F.F. (18" U.O.N.) *BRANCH CIRCUIT SOURCE PANELBOARD INDICATED IN PARENTHESIS FOR REFERENCE WHEN HOMERUN IS NOT VISIBLE ON PLAN. GENERAL NOTES: 1. WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL LIGHTING FIXTURES, RECEPTACLES, OUTLETS, ETC. INDICATED WITH CIRCUIT NUMBERS AND PANEL DESIGNATIONS. REFER TO SPECIFICATIONS FOR APPLICABLE MEANS AND METHODS. 2. ALTHOUGH ALL BRANCH CIRCUIT WIRE AND CONDUIT IS NOT SHOWN, IT IS THE INTENT OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WIRING SYSTEM BE INSTALLED. 3. WIRING SHALL BE 2#12+1#12G IN 3/4"C MINIMUM. RECEPTACLE BRANCH CIRCUIT WIRING SCHEDULE CONDUCTOR MAXIMUM CONDUCTOR LENGTH AT 120V GROUND AWG. AWG. #12 100'-0" #12 #10 165'-0" #10 #8 255'-0" #10 #6 405'-O" #10 RECEPTACLE BRANCH CIRCUIT WIRING SCHEDULE NOTES: 1. BASED ON 20A CIRCUIT LOADED TO 9A USING SINGLE PHASE, 2 WIRE CIRCUITS. 2. THE ABOVE SCHEDULE REPRESENTS MINIMUM CONDUCTOR SIZE BASED FROM PANEL TO CENTER OF LEAD TO OVERCOME VOLTAGE DROP. 3. MAKE PROVISIONS FOR JUNCTION BOX ADJACENT TO OUTLET TO TRANSITION TO #12 WIRE FOR FINAL TERMINATIONS TO DEVICE AS REQUIRED. LIGHTING BRANCH CIRCUIT WIRING SCHEDULE CONDUCTOR MAXIMUM CONDUCTOR MAXIMUM CONDUCTOR GROUND AWG. LENGTH AT 120V LENGTH AT 120V AWG. #12 75'-0" 175'-0" #12 #10 120'-0" 285'-0" #10 #8 190'-0" 445'-O" #10 #6 300'-0" - #10 LUMINAIRE BRANCH CIRCUIT WIRING SCHEDULE NOTES: 1. BASED ON 20A CIRCUIT LOADED TO 12A USING SINGLE PHASE, 2 WIRE CIRCUITS, 2. THE ABOVE SCHEDULE REPRESENTS MINIMUM CONDUCTOR SIZE BASED FROM PANEL TO CENTER OF LEAD TO OVERCOME VOLTAGE DROP. 3. MAKE PROVISIONS FOR JUNCTION BOX ADJACENT TO OUTLET TO TRANSITION TO #12 WIRE FOR FINAL TERMINATIONS TO DEVICE AS REQUIRED. GENERAL NEW WORK NOTES 1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL TRADE DOCUMENTS PRIOR TO SUBMITTING A BID IN ORDER TO GET A COMPLETE UNDERSTANDING OF THE ENTIRE SCOPE OF WORK. ALL WORK FOR OTHER TRADES THAT REQUIRE ELECTRICAL CONNECTIONS, TERMINATIONS, ETC ARE INCLUDED IN THIS SCOPE OF WORK UNLESS OTHERWISE SPECIFIED. 2. WIRING AND CONDUIT OR MC CABLE SHALL BE REQUIRED BETWEEN ALL LIGHT FIXTURES, SWITCHES, SENSORS, POWER PACKS, RELAYS, AND OTHER AUXILIARY DEVICES. 3. PROVIDE A NYLON PULL CORD IN ALL EMPTY CONDUITS. 4. COORDINATE WITH SECURITY VENDOR PLANS FOR EXACT ELECTRICAL REQUIREMENTS FOR SECURITY SYSTEM. PROVIDE ALL ASSOCIATED POWER CONNECTIONS AND EMPTY RACEWAY SYSTEM AND BOXES. PROVIDE PLASTIC END BUSHINGS AND PULL STRINGS IN ALL CONDUITS. 5. COORDINATE WITH A/V VENDOR PLANS FOR EXACT ELECTRICAL REQUIREMENTS FOR A/V SYSTEM. PROVIDE ALL ASSOCIATED POWER CONNECTIONS AND EMPTY RACEWAY SYSTEM AND BOXES. PROVIDE PLASTIC END BUSHINGS AND PULL STRINGS IN ALL CONDUITS. 6. FURNISH LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR THE PROPER AND COMPLETE INSTALLATION OF ALL ELECTRIC WORK SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED. 7. ALL ITEMS NOT SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH ARE NECESSARY TO MAKE A COMPLETE ELECTRICAL INSTALLATION, SHALL BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. 8. ALL ELECTRICAL INSTALLATIONS AND GROUNDING SHALL BE IN STRICT ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE LOCAL, STATE AND NATIONAL CODES. 9. MATERIALS AND WORKMANSHIP SHALL BE THE BEST OF THEIR RESPECTIVE KIND AND IN FULL ACCORDANCE WITH THE MOST MODERN ELECTRICAL CONSTRUCTION STANDARDS. ALL MATERIAL SHALL BE NEW, UNLESS OTHERWISE NOTED AND FREE OF ANY DEFECTS. 10. ALL WORK SEQUENCES SHALL BE COORDINATED WITH THE OWNER, ARCHITECT AND OTHER BUILDING TRADES PRIOR TO THE INITIATION OF ANY WORK. 11. ALL BRANCH CIRCUITS RATED AT 120 VOLTS, 20 AMPERES EXCEEDING 75 FEET SHALL BE MINIMUM #10 AWG. 12. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH INDIVIDUAL ELECTRICAL SYSTEM REPRESENTATIVES IN ORDER TO INCLUDE ALL REQUIRED AUXILIARY EQUIPMENT AND MATERIALS FOR A COMPLETE INSTALLATION. 13. INFORMATION AND COMPONENTS SHOWN ON RISER DIAGRAMS BUT NOT ON PLANS, AND VICE VERSA, SHALL APPLY OR SHALL BE PROVIDED AS THOUGH EXPRESSLY REQUIRED ON BOTH. IT IS NOT INTENDED THAT EVERY JUNCTION BOX, OFFSET, FITTING OR COMPONENT BE SPECIFIED OR SHOWN ON THESE DRAWINGS; HOWEVER, CONTRACT DOCUMENTS REQUIRE PROVISION OF ALL COMPONENTS AND MATERIALS NECESSARY FOR COMPLETE AND OPERATIONAL ELECTRICAL INSTALLATION, WHETHER OR NOT INDICATED OR SPECIFIED. 14. BRANCH CIRCUIT WIRING MAY NOT BE GRAPHICALLY SHOWN ON DRAWINGS AND MAY BE SHOWN BY CIRCUIT NUMBERS BESIDE FIXTURES, DEVICES AND EQUIPMENT. PROVIDE COMPLETE WIRING SYSTEM WHETHER OR NOT SHOWN GRAPHICALLY. WIRING IS SHOWN BY CONDUIT RUNS ON DRAWINGS WHERE SPECIFIC ROUTING IS REQUIRED OR FOR OTHER SPECIAL REASONS. ONLY ROOMS WITH MULTIPLE SWITCHING HAVE "SWITCH CONTROL LETTERS" ASSIGNED. ALL WIRING SHALL BE RUN IN A NEAT AND ORDERLY MANNER. 15. PROVIDE THHN CONDUCTORS IN AREAS WITH HIGH AMBIENT TEMPERATURES SUCH AS BOILER ROOMS, INCINERATOR ROOMS, MECHANICAL EQUIPMENT ROOMS ETC., FOR SIZES LARGER THAN NO. 10 AWG. 16. ALL WIRING, BUSSING, WINDINGS, AND ALL OTHER CONDUCTORS ARE BASED ON THE USE OF COPPER UNLESS OTHERWISE SPECIFIED. 17. ALL WIRING SHALL BE COLOR CODED. WIRING SHALL BE CONCEALED UNLESS OTHERWISE NOTED. 18. PROVIDE CONDUIT SLEEVES AS REQUIRED. THROUGH FIRE RATED SEPARATIONS, FIRE SEAL AFTER WIRING IS COMPLETE. 19. WIRING SHALL NOT BE LAID ON, OR ATTACHED TO THE SUSPENDED CEILING OR ITS SUPPORT WIRES. ALL CABLES SHALL BE RUN PARALLEL OR PERPENDICULAR TO WALLS. DO NOT RUN CABLES DIAGONALLY THROUGH ANY SPACE. 20. WHERE THE NUMBER OF CURRENT CARRYING CONDUCTORS IN A RACEWAY OR CABLE EXCEEDS THREE, THE ALLOWABLE AMPACITY SHALL BE REDUCED PER NATIONAL ELECTRIC CODE TABLE BASED ON NO DIVERSITY. CONSIDER NEUTRALS TO BE CURRENT CARRYING CONDUCTORS. 21. DO NOT COMBINE CIRCUITS OR USE COMMON NEUTRALS. 22. LABEL ("BROTHER P-TOUCH LABELING SYSTEM" OR APPROVED EQUAL) OR ENGRAVE EACH RECEPTACLE PLATE WITH PANEL DESIGNATION AND CIRCUIT NUMBER. 23. CONTRACTOR SHALL VISITTHE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS. NO CLAIM FOR EXTRA COMPENSATION SHALL BE ENTERTAINED FOR WORK WHICH A PRELIMINARY EXAMINATION WOULD HAVE REVEALED. THE SUBMISSION OF A BID WILL BE CONSIDERED AS ACKNOWLEDGMENT ON THE PART OF THE BIDDER OF HIS VISITATION TO THE SITE. 24. OBTAIN ALL NECESSARY PERMITS AND CERTIFICATES. PRESENT SATISFACTORY PROOF OF FINAL INSPECTION AND APPROVAL BY AUTHORITIES HAVING JURISDICTION. 25. MAINTAIN CORRECT PHASE SEQUENCE OF ALL FEEDERS AND CIRCUITS BY ESTABLISHING PHASE IDENTIFICATION AND MAINTAINING CORRECT RELATIONSHIP THROUGHOUT THE SYSTEM. PROVIDE LINE BALANCE WITHIN 10% OF NORMAL LOADS. 26. PROVIDE FLUSH, LOCKING, WEATHERPROOF "WHILE IN USE" TYPE RECEPTACLE ENCLOSURE; C.W. COLE # TL310-WCS-SH-GFCI-CC (FINISH SELECTED BY THE ARCHITECT); TYPICAL FOR ALL EXTERIOR RECEPTACLES. 27. PROVIDE TAMPER RESISTANT RECEPTACLES PER NEC ARTICLE 406.12. FIRE ALARM LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT FIRE ALARM DEVICES: ALL FIRE ALARM NOTIFICATION DEVICES SHALL BE MOUNTED AT 80" A.F.F. TO BOTTOM OF STROBE LENS, UNLESS OTHERWISE NOTED. ALL FIRE ALARM PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO CENTER OF DEVICE. REMOTE TEST SWITCHES SHALL BE MOUNTED AT 7'-0" A.F.F. IN CORRIDOR BELOW DUCT SMOKE DETECTOR. THE FOLLOWING DESIGNATIONS SHALL APPLY TO ALL FIRE ALARM DEVICES; UNLESS OTHERWISE NOTED: WP = WEATHERPROOF. CLG = CEILING MOUNTED. K = KEY OPERATED TEST SWITCH. WG = WIRE GUARD. SC = STOPPER COVER. OAS FIRE ALARM SMOKE DETECTOR. FIRE ALARM HEAT DETECTOR, COMBINATION RATE -OF -RISE AND ONE OR/F HUNDRED THIRTY-FIVE DEGREES (135°) F FIXED TEMPERATURE. FIRE ALARM DUCT MOUNTED SMOKE DETECTOR, INSTALLED BY MECHANICAL S CONTRACTOR, WIRED AND FURNISHED BY ELECTRICAL CONTRACTOR. 15cd � HORN/STROBE COMBINATION. CANDELA RATING SHALL BE 15, UNLESS OTHERWISE NOTED. 15cd FIRE ALARM STROBE ONLY. CANDELA RATING SHALL BE 15, UNLESS OTHERWISE NOTED. 15cd� HORN/STROBE COMBINATION; CEILING MOUNTED. CANDELA RATING SHALL BE 15, UNLESS OTHERWISE NOTED. 15cd FIRE ALARM STROBE ONLY; CEILING MOUNTED. CANDELA RATING SHALL BE 15, C UNLESS OTHERWISE NOTED. SELF CONTAINED CARBON MONOXIDE DETECTOR, 120 VOLT WITH BATTERY OCO BACKUP. INTERCONNECTABLE. SELF CONTAINED SMOKE DETECTOR, 120 VOLT, PHOTOELECTRIC TYPE, WITH OP BATTERY BACKUP. INTERCONNECTABLE. 0AS SELF CONTAINED COMBINATION SMOKE AND CARBON MONOXIDE DETECTOR, CO 120 VOLT, WITH BATTERY BACKUP, INTERCONNECTABLE. FRCP I FIRE ALARM CONTROL PANEL. FF-A-R-Al FIRE ALARM REMOTE ANNUNCIATOR. FAGM FIRE ALARM GRAPHIC MAP. FAWC FIRE ALARM WIRELESS COMMUNICATOR. FAAC FIRE ALARM AS -BUILT CABINET. FA-7 FIRE ALARM TERMINAL CABINET. F-RT-51 FIRE ALARM KEYED DUCT SMOKE REMOTE TEST STATION. �F FIRE ALARM PULL STATION. IM FIRE ALARM ISOLATION MODULE. AIM FIRE ALARM MONITOR MODULE. oM FIRE ALARM CONTROL MODULE. PROVIDE AN INTERMEDIATE RELAY TO SUIT LOAD. INTERMEDIATE RELAY, PROVIDE AS NEEDED. �K KEY ACCESS BOX. ® FIRE ALARM RADIO MASTER BOX ANTENNA, MOUNT AT HIGHEST POINT ON BUILDING EXTERIOR, FIRE ALARM SPRINKLER FLOW SWITCH, BY OTHERS. FURNISHED AND WF INSTALLED BY THE FIRE PROTECTION CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. FIRE ALARM SPRINKLER PRESSURE SWITCH, BY OTHERS. FURNISHED AND PS INSTALLED BYTHE FIRE PROTECTION CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. FIRE ALARM SPRINKLER TAMPER SWITCH, BY OTHERS. FURNISHED AND TS INSTALLED BY THE FIRE PROTECTION CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. i FIRE ALARM SYSTEM MASTERBOX. FIRE BELL, FURNISHED BY FIRE PROTECTION CONTRACTOR, WIRED AND FB INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE WIRING PER THE MANUFACTURER'S RECOMMENDATIONS (120V OR 24V). FIRE ALARM BEACON. DK FIRE ALARM DRILL KEY. POWER OUTLETS & DEVICES LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT POWER RECEPTACLES: ALL RECEPTACLES SHALL BE MOUNTED AT 18" A.F.F. TO CENTER, UNLESS OTHERWISE NOTED. THE FOLLOWING DESIGNATIONS SHALL APPLY TO ALL RECEPTACLES TYPES: C = MOUNTED AT 6" ABOVE BACK SPLASH TO BOTTOM, REFER TO ARCHITECTURAL ELEVATIONS FOR COORDINATION. CLG = CEILING MOUNTED. DW = DISHWASHER. EWC = ELECTRIC WATER COOLER. GD = GARBAGE DISPOSAL. HD = HAND DRYER. IG - ISOLATED GROUND. M = MICROWAVE. T = TAMPER RESISTANT. TL = TWIST LOCK. WP = WEATHERPROOF. Cp SINGLE RECEPTACLE ON NORMAL CIRCUIT. DUPLEX RECEPTACLE ON NORMAL CIRCUIT. CEILING MOUNTED DUPLEX RECEPTACLE ON NORMAL CIRCUIT. DOUBLE DUPLEX RECEPTACLE ON NORMAL CIRCUIT. `It' DUPLEX GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE ON NORMAL CIRCUIT. fXX-XXR SPECIAL PURPOSE RECEPTACLE WITH NEMA CONFIGURATION TO MATCH EQUIPMENT. JOY JUNCTION BOX. U2 DUPLEX RECEPTACLE (TAMPER RESISTANT) W/ (1) USB TYPE A PORT AND (1) USB TYPE C PORT. U4 DUPLEX RECEPTACLE (TAMPER RESISTANT) W/ (2) USB TYPE A PORTS AND (2) USB TYPE C PORTS. F-B1 # FLOOR BOX; REFER TO FLOOR BOX DEVICE SCHEDULE FOR ADDITIONAL INFORMATION. FF # FURNITURE FEED DEVICE; REFER TO FURNITURE FEED DEVICE SCHEDULE FOR ADDITIONAL INFORMATION. SURFACE METAL RACEWAY, EQUAL TO WIREMOLD SERIES 3000. PROVIDE WITH RECEPTACLES AS INDICATED ON PLANS WITH ACCESSORIES (ELBOWS, COVERS, COUPLINGS, ETC.) FOR A CONTINUOUS, COMPLETE INSTALLATION. COLOR BY ARCHITECT, IVORY OR GRAY. SURFACE METAL RACEWAY, EQUALTO WIREMOLD SERIES 4000. PROVIDE WITH RECEPTACLES AND TECHNOLOGY OUTLETS AS INDICATED ON PLANS WITH ACCESSORIES (ELBOWS, COVERS, COUPLINGS, DIVIDERS, ETC.) FOR A CONTINUOUS, COMPLETE INSTALLATION. COLOR BY ARCHITECT, IVORY OR GRAY. PLUGMOLD. El ❑P -I POWER FURNITURE FEED. EMGB ELECTRICAL MAIN GROUNDING BUSBAR. SPD SURGE PROTECTIVE DEVICE. LIGHTING FIXTURE LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT A LIGHT FIXTURE (LUMINAIRE) ON NORMAL CIRCUIT. LETTER INDICATES TYPE. ®a SUBSCRIPT INDICATES CONTROL AND CIRCUIT NUMBER. AE LIGHT FIXTURE (LUMINAIRE) TO BE PROVIDED WITH INTEGRAL BATTERY ®a BACKUP. LETTER INDICATES TYPE. SUBSCRIPT INDICATES CONTROL AND CIRCUIT NUMBER. o-p SITE LIGHT FIXTURE (LUMINAIRE). REFER TO POLE BASE DETAIL. ®� EXIT SIGN, ONE OR TWO FACED. ARROWS DENOTE DIRECTION. SHADING DENOTES NUMBER AND ORIENTATION OF SIGN FACE(S). EXIT SIGN WITH EMERGENCY LIGHTS. ARROWS DENOTE DIRECTION. SHADING DENOTES NUMBER AND ORIENTATION OF SIGN FACE(S). EMERGENCY LIGHTING BATTERY UNIT WITH EMERGENCY LIGHTS EMERGENCY LIGHTING BATTERY UNIT WITH EMERGENCY LIGHTS AND REMOTE CAPACITY Ak REMOTE EMERGENCY HEAD _INV_j INVERTER. POWER DISTRIBUTION LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT ® 480Y/277 VOLT PANELBOARD, SURFACE MOUNTED, REFER TO SCHEDULE OF PANELBOARDS. 480Y/277 VOLT PANELBOARD, FLUSH MOUNTED, REFER TO SCHEDULE OF PANELBOARDS. 208Y/120 VOLT PANELBOARD, SURFACE MOUNTED, REFER TO SCHEDULE OF PANELBOARDS. = 208Y/120 VOLT PANELBOARD, FLUSH MOUNTED, REFER TO SCHEDULE OF PANELBOARDS, METER SOCKET AND UTILITY COMPANY ELECTRIC METER, OR AS NOTED. 0 ENCLOSED CIRCUIT BREAKER. LIGHTING CONTROL LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT Sa SINGLE POLE SWITCH. SUBSCRIPT INDICATES LIGHT FIXTURE CONTROL. 120V ASTRONOMICAL TIME SWITCH WITH OILED DISPLAY, EQUALTO STCa WATTSTOPPER #RT-200,MOUNTED AT 48" A.F.F TO CENTER. SUBSCRIPT INDICATES LIGHT FIXTURE CONTROL. SWSa WATTSTOPPER #DSW-301 OCCUPANCY SENSOR, WALL MOUNTED AT 48" A.F.F. CEILING MOUNTED PHOTOSENSOR FOR DAY LIGHT HARVESTING. EQUAL TO WATTSTOPPER #LMLS-500. PHOTOSENSOR PLACEMENT PER MANUFACTURER'S RECOMMENDED LOCATIONS. PLACEMENT ON FLOOR PLANS IS DIAGRAMMATICAL. CEILING MOUNTED DIGITAL DUALTECHNOLOGY OCCUPANCY SENSOR, PASSIVE INFRARED AND ULTRASONIC TECHNOLOGY, EQUAL TO WATTSTOPPER #LMDC-100, PROVIDE WITH POWER PACK. MOUNT AT LEAST 6-0" FROM A SUPPLY REGISTER. LOWER CASE LETTER INDICATES SWITCH CONTROL. TIME OS a DELAY SHALL BE 15 MINUTES. POWER PACK SHALL BE LOCATED ABOVE CEILING, ABOVE SENSOR. MOUNT OCCUPANCY SENSOR AT SAME HEIGHT OR BELOW ANY PENDANT MOUNTED LIGHTING FIXTURES SO AS TO NOT OBSTRUCT OCCUPANCY SENSOR. WALL/CORNER MOUNTED DIGITAL DUAL TECHNOLOGY OCCUPANCY SENSOR, PASSIVE INFRARED AND ULTRASONIC TECHNOLOGY, EQUAL TO WATTSTOPPER #LMDX-100, PROVIDE WITH POWER PACK. MOUNT AT LEAST 6'-0" FROM A SUPPLY REGISTER. LOWER CASE LETTER INDICATES SWITCH CONTROL. TIME Ha DELAY SHALL BE 15 MINUTES. POWER PACK SHALL BE LOCATED ABOVE CEILING, ABOVE SENSOR. MOUNT OCCUPANCY SENSOR AT SAME HEIGHT OR BELOW ANY PENDANT MOUNTED LIGHTING FIXTURES SO AS TO NOT OBSTRUCT OCCUPANCY SENSOR. TC TIMECLOCK TELECOMMUNICATION LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT TELECOMMUNICATION OUTLETS: COORDINATE ALL LOCATIONS AND MOUNTING HEIGHTS WITH OWNERS AND TELECOMMUNICATIONS VENDOR PRIOR TO ROUGH -IN; MOUNT VERTICAL OUTLETS AT 18"A.F.F. TO CENTER UNLESS OTHERWISE DIRECTED. THE DESIGNATIONS SHALL APPLY TO ALL OUTLET TYPES: C = INDICATES MOUNTED AT 6" ABOVE BACK SPLASH TO BOTTOM, REFER TO ARCHITECTURAL ELEVATIONS. F = INDICATES FLOOR MOUNTED. P = INDICATES MOUNTED AT 47" A.F.F. W = INDICATES MOUNTED AT 54" A.F.F. H - INDICATES MOUNTED AT 82" A.F.F. TELECOMMUNICATIONS OUTLET, REFER TO TELECOMMUNICATIONS FACEPLATE DETAIL FOR ADDITIONAL INFORMATION. WIRELESS ACCESS POINT. CEILING OR WALL MOUNTED. REFER TO TELECOMMUNICATIONS FACEPLATE DETAIL FOR ADDITIONAL INFORMATION. ❑D ❑D -I TELECOMMUNICATIONS FURNITURE FEED. MGB MAIN TELECOMMUNICATIONS GROUND BAR, TGB TELECOMMUNICATIONS GROUND BAR. TELECOMMUNICATION TERMINAL BOARD, PROVIDE GRADE "A", 3/4" PLYWOOD COMPLETELY PAINTED WITH FIREPROOF PAINT AS REQUIRED PER CODE. BUILDING GROUNDING GRID LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT GROUND ROD. a G BUILDING GROUND CABLE. EXOTHERMIC BONDING CONNECTION. f� BOLTED BONDING CONNECTION. MOTOR AND CONTROLS LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT SEM BOILER EMERGENCY SWITCH. AROW-HART#CS120 WITH MULLBERRY#41020 PLATE. SINGLE POLE MOTOR RATED SWITCH WITH OVERLOAD HEATER (MANUAL ST MOTOR STARTER). EIJ UN -FUSED DISCONNECT SWITCH WITH RATINGS. 30/3/1 �NEMA RATING. "WP" INDICATES RAINTIGHT NUMBER OF POLES SWITCH SIZE 01 FUSED DISCONNECT SWITCH WITH RATINGS. 30/20/3/DE/1 LNEMA RATING. "WP" INDICATES RAINTIGHT INDICATES DUAL ELEMENT FUSES NUMBER OF POLES FUSE SIZE. %F" INDICATES NON FUSED SWITCH SIZE MOTOR; "3" INDICATES HORSEPOWER RATING. XXX EQUIPMENT TAG, REFER TO MECHANICAL EQUIPMENT SCHEDULE FOR MORE XX INFORMATION. PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 m MO o C",U oU L1J Q �uj U�u Ov �o W°� O� 10 � o C`7 `0 ov � N � w Lri Ln v J = V)00 0 Lo W LL z w. � N Q cV z J ce W Z N w U CO Q o N � O � � `p cct 0 0 r,_ 00 M M M ♦� O a-, M M Z 0 qO O O U 0 ooc O �Z a M 00 STAMP: }�Rfiilfll9wAAlf0f'f �f s FLCR' ` • �Y _1 "'+.��sr+�+•�� ISSUE: DATE: ISSUED FOR PERMIT Ol /25/2023 DRAWING SCALE: NOTED DRAWN BY: SB CHECKED BY: MD DRAWING TITLE: ELECTRICAL - LEGENDS & SYMBOLS DRAWING NUMBER: 0,0 GENERAL DEMOLITION NOTES 1. PRIOR TO SUBMITTING BID, VISIT SITE AND IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT WORK OF THIS SECTION. RENOVATION WORK WILL REQUIRE CAREFUL SITE EXAMINATION PRIOR TO BIDDING, NO COMPENSATION WILL BE GRANTED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY AN EXPERIENCED OBSERVER. FIELD VERIFY MEASUREMENTS AND CIRCUITING ARRANGEMENTS THAT ARE AS SHOWN ON DRAWINGS. 2. FIELD VERIFY THAT ABANDONED WIRING AND EQUIPMENT SERVE ONLY ABANDONED FACILITIES. 3. DEMOLITION DRAWINGS ARE BASED ON CASUAL FIELD OBSERVATION AND EXISTING RECORD DOCUMENTS. REPORT DISCREPANCIES TO ARCHITECT/ENGINEER BEFORE DISTURBING EXISTING INSTALLATIONS. THESE DRAWINGS HAVE BEEN COMPILED FROM THE BEST AVAILABLE INFORMATION AND ARE NOT INTENDED TO LIMIT THE SCOPE OF THE WORK. THE ELECTRICAL CONTRACTOR MAY ENCOUNTER HIDDEN OR COVERED CONDITIONS, NOT INDICATED IN THESE DOCUMENTS, REQUIRING THE ELECTRICAL CONTRACTOR TO PROVIDE ADDITIONAL WORK FOR THE COMPLETION OF HIS OR HER CONTRACT. IT WILL BE ASSUMED THAT THE CONTRACTOR HAS INSPECTED THE SITE PRIOR TO BIDDING AND VERIFIED THE INFORMATION SUPPLIED HEREIN AND ADDITIONAL WORK REQUIRED. BEGINNING OF DEMOLITION MEANS THE CONTRACTOR ACCEPTS EXISTING CONDITIONS. REFER TO ALL CONSTRUCTION DOCUMENTS TO GAIN A COMPLETE UNDERSTANDING OF THE DEMOLITION WORK REQUIRED. 4. CUT, REMOVE AND LEGALLY DISPOSE OF SELECTED ELECTRICAL EQUIPMENT, COMPONENTS AND MATERIALS AS INDICATED, INCLUDING, BUT NOT LIMITED TO, REMOVAL OF ELECTRICAL ITEMS INDICATED TO BE REMOVED AND ITEMS MADE OBSOLETE BY THE WORK. DISCONNECT AND REMOVE ALL FIXTURES, WIRING DEVICES, CONDUIT AND FITTINGS, WIRING AND CABLE, FIRE ALARM DEVICES/COMPONENTS, HANGERS, SUPPORTS, WIREWAYS, AND ALL OTHER ELECTRICAL COMPONENTS MADE OBSOLETE BY THIS PROJECT. THE OWNER RESERVES THE OPTION OF SALVAGE RIGHTS TO DEMOLISHED MATERIAL AND REMOVED EQUIPMENT. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER'S REPRESENTATIVE TO OBTAIN A LIST OF MATERIALS AND REMOVED EQUIPMENT TO BE TURNED OVER TO THE OWNER. ALL OTHER MATERIAL AND REMOVED EQUIPMENT NOT BEING SALVAGED BY THE OWNER SHALL BE DISPOSED OF BY THE CONTRACTOR. PLACE ALL DEMOLISHED ELECTRICAL MATERIALS EXCEPT HAZARDOUS MATERIALS (PCB LIGHTING BALLASTS, FLUORESCENT LAMPS, ETC.) AS DETERMINED BY THE AUTHORITY HAVING JURISDICTION IN GENERAL CONTRACTOR'S DUMPSTER. ALL HAZARDOUS ELECTRICAL MATERIALS SHALL BE LEGALLY DISPOSED OF BY THE ELECTRICAL SUBCONTRACTOR. S. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS SCHEDULED FOR REMOVAL. 6. MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS WHICH REMAIN ACTIVE. MODIFY INSTALLATION OR PROVIDE ACCESS PANELS AS APPROPRIATE. TEMPORARY WALL OPENINGS AND/OR MODIFICATIONS REQUIRED FOR REMOVAL/INSTALLATION OF EQUIPMENT SHALL BE PROVIDED AS NEEDED AND COORDINATED WITH THE GENERAL CONTRACTOR. ALL HVAC, PLUMBING AND FIRE PROTECTION EQUIPMENT SCHEDULED TO BE REMOVED OR RELOCATED SHALL BE DONE SO BY THE HVAC AND PLUMBING CONTRACTOR RESPECTIVELY. THE ELECTRICAL CONTRACTOR SHALL REMOVE STARTERS, DISCONNECT SWITCHES, WIRING, AND CONDUIT FOR SAID EQUIPMENT. REFER TO HVAC AND PLUMBING DRAWINGS FOR SCOPE OF WORK. 7. PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION. WHEN WORK MUST BE PERFORMED ON ENERGIZED EQUIPMENT OR CIRCUITS USE PERSONNEL EXPERIENCED IN SUCH OPERATIONS. 8. EXISTING FIRE ALARM SYSTEM: MAINTAIN THE EXISTING SYSTEM IN SERVICE UNTIL THE MODIFIED/EXPANDED SYSTEM IS TESTED AND ACCEPTED BY THE FIRE DEPARTMENT. DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. NOTIFY OWNER, ARCHITECT/ENGINEER AND LOCAL FIRE DEPARTMENT AT LEAST TEN DAYS BEFORE PARTIALLY OR COMPLETELY DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREAS ADJACENT TO WORK AREA AS REQUIRED OR PROVIDE A "FIRE -WATCH" SYSTEM COORDINATED WITH THE LOCAL FIRE DEPARTMENT. 9. EXTEND EXISTING ELECTRICAL INSTALLATIONS AS CALLED FOR ON THE DRAWINGS. 10. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. 11. REMOVE ABANDONED WIRING TO SOURCE OF SUPPLY. 12. REMOVE EXPOSED ABANDONED CONDUIT, INCLUDING ABANDONED CONDUIT ABOVE ACCESSIBLE CEILING FINISHES. CUT CONDUIT FLUSH WITH WALLS AND FLOORS, AND PATCH SURFACES. 13. DISCONNECT ABANDONED OUTLETS AND REMOVE DEVICES. REMOVE ABANDONED OUTLETS IF CONDUIT SERVICING THEM IS ABANDONED AND REMOVED. PROVIDE BLANK COVER FOR ABANDONED OUTLETS WHICH ARE NOT REMOVED. 14. DISCONNECT AND REMOVE ELECTRICAL DEVICES AND EQUIPMENT SERVING UTILIZATION EQUIPMENT THAT HAS BEEN REMOVED. 15. DISCONNECT AND REMOVE ABANDONED LIGHTING FIXTURES. REMOVE BRACKETS, STEMS, HANGERS, AND OTHER ACCESSORIES. 16. DISCONNECT AND REMOVE OTHER SYSTEMS AND EQUIPMENT WITHIN THE WORK AREA MADE OBSOLETE BY THIS WORK. 17. PROTECT ALL EXISTING WALLS, FLOORS, CEILINGS, LIGHT FIXTURES, ETC, WHICH ARE TO REMAIN AND TO PREVENT DAMAGE DURING ALL CONSTRUCTION PHASES. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK. PROVIDE AND MAINTAIN TEMPORARY PARTITIONS OR DUST BARRIERS ADEQUATE TO PREVENT THE SPREAD OF DUST AND DIRT TO ADJACENTAREAS. PROTECTTHE STRUCTURE, FURNISHINGS, FINISHES, AND ADJACENT MATERIALS NOT INDICATED OR SCHEDULED TO BE REMOVED. PROTECT THE ELECTRICAL WORK AND THE WORK OF OTHERS IN A MANNER BEST SUITED TO THE PARTICULAR CASE. CORRECT ANY DAMAGE DONE TO ANY WORK AT NO ADDITIONAL COST. 18. EXTEND EXISTING INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. 19. CLEAN AND REPAIR EXISTING MATERIALS AND EQUIPMENT WHICH REMAIN OR ARE TO BE REUSED. 20, PANELBOARDS: CLEAN EXPOSED SURFACES AND CHECK TIGHTNESS OF ELECTRICAL CONNECTIONS. REPLACE DAMAGED CIRCUIT BREAKERS AND PROVIDE CLOSURE PLATES FOR VACANT POSITIONS. PROVIDE TYPED CIRCUIT DIRECTORY SHOWING REVISED CIRCUITING ARRANGEMENT. 21. LIGHTING FIXTURES: EXISTING LIGHTING FIXTURES SCHEDULED FOR REUSE SHALL BE REMOVED FOR CLEANING. USE MILD DETERGENT TO CLEAN ALL EXTERIOR AND INTERIOR SURFACES; RINSE WITH CLEAN WATER AND WIPE DRY. REPLACE LAMPS, BALLASTS AND BROKEN ELECTRICAL PARTS. 22. EXISTING ELECTRICAL EQUIPMENT AND WIRING NOT SHOWN ON DOCUMENTS OR ADDRESSED BY NOTES ABOVE SHALL BE CONSIDERED EXISTING TO REMAIN. EXISTING ELECTRICAL EQUIPMENT LEGEND ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT �F 0 EXISTING ELECTRICAL EQUIPMENT WITHOUTA DESIGNATION IS TO REMAIN. XE XE XE XE "XE" INDICATES EXISTING ELECTRICAL EQUIPMENT WHICH IS TO BE REMOVED. LFJ 2 0 P PULL BACK WIRING AND CONDUIT BACK TO NEXT ACTIVE OUTLET OR POWER SOURCE. XR XR XR "XR" INDICATES EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED AND M 2 XR I1TI RELOCATED. EXISTING CIRCUIT SHALL BE EXTENDED TO NEW LOCATION OF tY RELOCATED EXISTING ELECTRICAL EQUIPMENT. XNXNXNXN XN 2 7 [P "XN" INDICATES NEW LOCATION OF RELOCATED EXISTING ELECTRICAL EQUIPMENT. "ETR" INDICATES EXISTING EQUIPMENT/DEVICE TO REMAIN. EXISTING CIRCUIT/ ETR ETR ETR ETR WIRING SHALL BE REMOVED. PULL BACK WIRING AND CONDUIT BACK TO NEXT I F 27 IP ACTIVE OUTLET OR POWER SOURCE. ALL HVAC/PLUMBING INTERLOCKING WIRING SHALL REMAIN, REFER TO RENOVATION PLANS FOR NEW CIRCUIT INFORMATION. �XW, XW XW XW "XW" INDICATES EXISTING EQUIPMENT/DEVICE TO BE REMOVED. EXISTING M 2 01P CIRCUIT/WIRING AND BACK BOX SHALL REMAIN. NEW DEVICE SHALL BE XW XW XW XW LOCATED IN PLACE. EXTEND CIRCUIT/WIRING TO NEW ELECTRICAL nQ 0 qp EQUIPMENT/DEVICE. GENERAL NOTES: 1. DOTTED SYMBOLS INDICATE EXISTING ELECTRICAL EQUIPMENT. 2. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THE CONTINUITY OF ALL EXISTING CIRCUITS WHICH ARE REMAINING. CLG ETR fr 1 r TIfT -1- f- T►fr 1 r -nfr 1 U_J -1 L1JLLJ - R/F -nrr L1JU-J 1fr L_LILJ fr r 1 r 1 f--nfr 1 LL J L _UU_ J L _UH J L 1JLL J CIRCUIT TRACING NOTE ELECTRICAL CONTRACTOR SHALL UPDATE ALL EXISTING PANELBOARD DIRECTORIES TO REFLECT ALL CIRCUITS MADE SPARE FROM DEMOLITION. ALL EXISTING CIRCUIT BREAKERS IN ALL EXISTING PANELBOARDS SHOWN ON THE DRAWINGS SHALL BE TRACED OUT AND LABELED IN PANELBOARD OF ORIGIN. ALL CIRCUITS THAT ARE NO LONGER IN USE SHALL BE PULLED BACK TO PANEL OF ORIGIN. ALL CIRCUIT BREAKERS NOT BEING UTILIZED SHALL BE LABELED AS SPARE AND PUT IN THE OPEN (OFF) POSITION. KEYED NOTES r1 DISCONNECT AND THEN RECONNECT EXISTING CEILING MOUNTED RECEPTACLES TO �� ACCOMMODATE NEW CEILING. ETR _,I -nrr 1 rir�r —Ji L 1JLL J CLG ETR , y; r� —1 Uk r-11T 1 TR r -nrr - r -nrr —1 L SJLL J r-nfT1 L JL -i > rTfT1-._: R/F L _LILL. J rilfr1 L11LL.J LIILLJ L1IlLJ <�� �> <�� �J,> <�� �J,> CLG CLG ETR .._') ETR uR F-"f11T-1 TR r- -nff-4 , F -nfT-1 L11LL.J r -1fr 1 L HLL. jal r -nfr - R/F LJLLJ r ilfr-1 LIJLLJ L_ULJ L HU_J ET r ilff -1 � -nrr -1 L _LI L J L I IU_ J i -11 i- i P �a U U I r-n(T1 r�1fr-1ETR rT1fT1 rTI L 1JLL J L 1JL J L 1JLL J L 11 r Tif -1 r -nfr 1_ ___ R/F r TIIT 1 r it L _LILI_n n_ULI_n n_UULn /L_LI ETR ETR CLG CLG CLG CLG CLG CLG ETR ETR , ETR l,: ETR _ 0 ETR ETR .: ETR , ETR ETR ETR ETR ETR CLG ETR ETR ETR' EXISTING MAIN ELECTRIC ROOM EQUIPMENT IS EXISTING TO REMAIN. ETR ETR ETR ETR ETR ETR R/F ETR ;ETR ETR ETR ETR f, - - - - - ------ - - - --------- -_ --_- ______ -- - - - - - - - - �I XE XE j XE I 1 ------------------------ El°R� L---------------------------.li I IU ETR R/F i ETR - I � T -------`i �-------= — �;.__� ETR - - - -I r i r II I ETR I I XE XE IL - - - - - - - - - - - - - - - - - - ETR I II R/F R I I XEI ETR -JETR XE._ L_--------J ETR E ------ ETR - R/F - ETR - R/F ETR ETR ETR ETR" - -- R/F T ` �i ELECTRICAL DEMOLITION SCALE:1/8" =1'-0" 0 8' 0' 16'-0" 24'-0" ETR ETR ETR 'R/F ETR ETR ETR ETR ETR ETR_` ETR- ETR' ETR PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21161 (jr) 00 NU . o LU WqU LU U�� � <t J O U ce o W°� O�' w I _ o (y) `o ov w in I— u0 r �/ V) v V)"T 0 F_ Lo w u- w U w N N N Z qN y w r I. LJ_J Z N w U 00 Q o N L7 cy) F V _s4 o 0 ^, H M M M V/ 40, a C) ccn Q 0 00 00 O U 1� 4� N O 0PLO m 00 STAMP: .- ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: SB CHECKED BY: MD DRAWING TITLE: ELECTRICAL - DEMOLITION DRAWING NUMBER: ED 1,90 LIGHTING PLAN SHEET NOTES 1. LOCATIONS OF ALL SWITCHES SHALL COMPLY WITH ADA CRITERIA. 2. ALL BRANCH CIRCUIT CONDUCTORS SHALL BE 98% CONDUCTIVITY, COPPER MINIMUM #12 AWG SIZE, THWN/THHN INSULATION, 600 VOLTS RATED UNLESS OTHERWISE NOTED. 3. EXACT LOCATIONS OF ALL FIXTURES AND DEVICES SHALL BE FULLY COORDINATED WITH ARCHITECTURAL PLANS, ELEVATIONS, SECTIONS, AND THE WORK OF OTHER TRADES PRIOR TO ROUGH -IN. 4. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE AND SMOKE RATED WALLS AND PROVIDE POWER METHODS OF PENETRATION FOR EACH. 5. LIGHT FIXTURES AND WIRING LOCATED IN AIR -HANDLING AREAS SHALL BE PLENUM RATED. 6. VERIFY ALL CEILING TYPES AND MATERIALS BEFORE ORDERING ANY LIGHT FIXTURES. 7. SUPPORT EACH LIGHT FIXTURE INDEPENDENTLY OF THE SUSPENDED CEILING SYSTEM AND COORDINATE LOCATIONS WITH REFLECTED CEILING PLAN AND OTHER TRADES TO AVOID CONFLICT. 8. ALL LIGHTS ON THIS PLAN SHALL BE FED FROM NEW PANEL "LP1". MAINTENANCE AREA 124 ELECTRICAL - LIGHTING PLAN SCALE:1/8" = V-0" 0 8'-0" 16'-0" 24'-0" SHOE ROOM 102 PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 M v/ ! o O O c� U _! U Lu ¢Lu l ) c) -I Ck�© U L° LI x3 O0 U- _"T (v) M 10 o 11r w Ln 0 w � � Z w u CIL N N 7 Q N 9-3e F- d. W zN w U °O Q o Chl L() M \� 0 kin 00 N © •pmm( M M kn 4. a N kn c� 3 o � CCU � � N OO 4-+ a M 00 STAMP: YFJ4 j� Pir Tom: t 4.� ♦y, OwOl 40 ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: SB CHECKED BY: MD DRAWING TITLE: ELECTRICAL- LIGHTING PLAN DRAWING NUMBER: El • KEYED NOTES NEW 200A PANEL "LP1" TO BE FED FROM EXISTING 1200A MDP. PROVIDE ONE (1) QUAD FLOOR BOXES WITH POWER FOR ARCADE GAMES. COORINATE EXACT LOCATION OF GAMES AND ROUTING REQUIREMENTS IN FIELD PRIOR TO ROUGH -IN. MECHANICAL CONNECTION SCHEDULE TAG REFER TO "ELECTRICAL CONNECTION SCHEDULE FOR MECHANICAL EQUIPMENT" IN XXX THIS DRAWING SET FOR ALL CIRCUIT INFORMATION, INCLUDING BUT NOT LIMITED XX TO BRANCH CIRCUIT WIRING AND CONDUIT SIZE, VOLTAGE, PHASE, MOTOR CONTROL, DISCONNECT SWITCH AND CIRCUIT BREAKER. REFER TO MECHANICAL, PLUMBING, AND FIRE PROTECTION PLANS FOR EXACT EQUIPMENT LOCATIONS. POWER PLAN NOTES 1. EXACT LOCATIONS OF ALL FIXTURES, DEVICES, AND EQUIPMENT SHALL BE FULLY COORDINATED WITH ARCHITECTURAL PLANS, ELEVATIONS, SECTIONS, AND THE WORK OF OTHER TRADES PRIOR TO ROUGH -IN. 2. TEL/DATA RECEPTACLES INDICATED ON THIS PLAN SHALL INCLUDE THE INSTALLATION OF WALL TERMINATION (WITH EXACT CONFIGURATION TO BE DETERMINED BY OWNER) WITH CONDUIT AND PULL STRING TO ABOVE CEILING LOCATION. 3. ALL BRANCH CIRCUIT CONDUCTORS SHALL BE 98% CONDUCTIVITY, COPPER MINIMUM #12 AWG SIZE, THWN/THHN INSULATION, 600 VOLTS RATED UNLESS OTHERWISE NOTED. 4. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE AND SMOKE RATED WALLS AND PROVIDE POWER METHODS OF PENETRATION FOR EACH. S. ALTHOUGH ALL BRANCH CIRCUIT WIRE AND CONDUIT IS NOT SHOWN, IT IS THE INTENT OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WIRING SYSTEM BE INSTALLED. 6. THE LOCATIONS OF HVAC EQUIPMENT SHOWN ON THESE DRAWINGS ARE APPROXIMATE. FOR EXACT LOCATIONS REFER TO HVAC DRAWINGS AND SHOP DRAWINGS. 7. HVAC EQUIPMENT RATED FOR 230V SHALL BE PROVIDED WITH AN APPROPRIATELY SIZED BUCK -BOOST TRANSFORMER. 8. ALL NEW POWER EQUIPMENT ON THIS PLAN TO BE FED FROM NEW PANEL "LP1". CIRCUIT NUMBERS REFLECT QUANTITY ONLY, E.C. SHALL DESIGNATE EXACT CIRCUIT BREAKERS IN FIELD. DN MAINTENANCE AREA 124 71 I I ° ®I 1r;vl-. ° Y.®I 3 � ® �� ��I j 1 � ! ! I ! I� ► � � ± �� I I :I I I I CLG ETR 1a ETR 77 2 � t� k CLG ETR CLG BOWLING AREA ETR 123 cSfi3. 6� '' 15 0� nJ x' t,xQ:?� d.,Q CLG CLG ETR :? ETR CLG CLG ETR ETR CORRIDOR 104 CLG ETR CLG ETR ETR 10 j _ WP 10 r=R- _7N ETR ETR ETR USB 1? I 117 RESTROOM� ETR MECH 18 ETR ETR ETR I 116 I VEST. VEST. 109 17 a 17 U I ETR I I 112 PRO SHOP ETR' MEN WOMEN 'ETR 0 � I 115 I O BAR USB I 113 111 I KITCHEN 122 LOCKER I 105 ROOM I POWER IN THIS AREA IS I O : lo 11� �USB 121 I EXISTING TO REMAIN. 114L_ I ETR ARCADE16 ETR ETR ETR ETR ETR USB 11 108 -- — — ------ — -- I � - ,: � J SHOP 0 db WALK-IN COOLER I ETR 118 12 ETR 12 13 ETR 106 ETR 11 I I_ I— II AMF F I B STORAGE L I POWER IN THIS AREA IS 119 I 2 EXISTING TO REMAIN. KITCHEN 7 107 ETR ETR ETR M14 ETR 15 ETR I ETR 13 ETR 14 ETR I —J UTILITY 120 ELECTRICAL- POWER PLAN SCALE:1/8" =1'-0" 0 8'-0" 16'-0" 24'-0" CLG ETR US B 19 ENTRY/ RECEPTION 101 USB BAR AREA _@19 103 ETR ETR ETR O ETR SHOE ROOM 102 ••--+ 00 0 O N N 1 04 P-+ ti C) f� N w PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 0 M O O N U <� W Qw �Q 06 W m� o� . 'o M 'o O v � N � w� �L0 00 _ �00 0 Ln Z F- uf U wCN F— N cn N Zry �I L1J Z N W V °O Q o N L0 M U t� ono • ^�, U 2) v� N c� knkn o Q yo000 O O O Z M o0 STAMP: N. �X t �`j'(-y�+'-TAT . qF'�� ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: SB CHECKED BY: MD DRAWING TITLE: ELECTRICAL - POWER PLAN DRAWING NUMBER: E 1 • 1 EMERGENCY LIGHTING SHEET NOTES 1. COORDINATE COLOR OF EXIT SIGN ILLUMINATION WITH OWNER/ARCHITECT PRIOR TO SHOP DRAWING REVIEW PROCESS. 2. EMERGENCY LIGHTING SHALL BE CIRCUITED AHEAD OF ANY AND ALL LIGHTING CONTROLS UNLESS OTHERWISE SPECIFIED, 3. GENERAL LIGHT FIXTURES WITH INTEGRAL BATTERY BACK- UP USED FOR THE PURPOSE OF EMERGENCY LIGHTING SHALL BE INSTALLED WITH A UL924 EMERGENCY BYPASS / SHUNT RELAY. FIRE ALARM SHEET NOTES 1. COORDINATE FIRE ALARM DEVICE MOUNTING WITH ARCHITECTURAL PLAN PRIOR TO INSTALLA TION, ANY DEVIATION FROM THE DESIGN S DOCUMENTS HALL BE M SUBMITTED TO THE ENGINEER IN WRITING FOR APPROVAL PRIOR TO ROUGH -IN. 2. COORDINATE WITH FIRE PROTECTION PLANS FOR LOCATIONS AND QUANTITIES OF FLOW TAMPER AND PRESSURE SWITCHES. PROVIDE MONITOR 0 DE A ON OR MODULE AT EACH DEVICE LOCATION TO TIE INTO THE FIRE ALARM CONTROL PANEL. 3. ALL NEW INITIATION AND NOTIFICATION DEVICES INCLUDED IN THIS SCOPE OF WORK SHALL BE COMPATIBLE WITH THE EXISTING FIRE ALARM CONTROL PANEL. VERIFY DEVICES ARE COMPATIBLE WITH FIRE ALARM MANUFACTURER PRIOR TO FURNISHING. 4. E.C. SHALL INCLUDE IN BID COORDINATION AND INSTALLATION OF A BI-DIRECTIONAL AMPLIFIER FOR FIRE DEPARTMENT COMMUNICATION. THIS SHALL BE INCLUDED AS A SEPARATE LINE ITEM IN THE BID AND SHALL INCLUDE: COORDINATION, FURNISHING INSTALLATION AND TESTING. IF DEEMED NOT I 0 REQUIRED BY THE FIRE DEPARTMENT, OR TESTING AGENCY A CREDIT SHALL BE ISSUED TO THE OWNER FOR THIS LINE ITEM. 5. E.C. SHALL FURNISH AND INSTALL REMOTE INDICATING LIGHTS/TESTSWITCHES FOR DUCT SMOKE DETECTORS. COORDINATE EXACT LOCATION IN FIELD, 6. E.C. SHALL PROVIDE ANY AND ALL AUXILIARY EQ UIPMENT IN ORDER TO PROVIDE A COMPLETE, PROPERLY FUNCTIONING SYSTEM. COORDINATE REQUIREMENTS WITH LOCAL MANUFACTURERS REP. 7. ALL FIRE ALARM STROBE SIGNAL DEVICES SHALL BE SYNCHRONIZED TYPE DEVICES AND COMPLY WITH ADA REQUIREMENTS. MAINTENANCE AREA 124 _ I I '�j I I !I I '! ! I I I �c I ��: i r�. 'q � .- J _ "�: .� 4G-�C t� .. ! I I J" it I ITT III I _ v @ @ I .. _{ _ ® � I 1 P � I—`: I li I .. F- I .. � r I � @ @. 1i9` J �' "1 @ �. � ! I '�I III I � 3'' `�"oi 1 9 � � 7� I � @ ,.�..-- ! .I l _ C: .- I� � �-: I I I to ;3 'c 4-'��-' � .- �03'���- + I! '�I i3' `�. — _ _ 5i, ' I I II i I I! ! —�° I I ri a-- :^ I I - I II r tTs J, 7�� Fb. ,. �rS _ i I •a''`-9 I � 3 _ _ 6' S�''t I I ��- Q �:, � � @ I I I � /rJ @ _ I II v _ f I � � I �2J JY �-' V ��'' y &3 .. .J � I I � x1�_... I IJ £v` i�— v _ I I I i ! I I II i i I I II li it I I ! Ii i II I . II I !i j'I I I I I li I I I I I I I I ! I I I !• I I II I it i li is I I!I I I I I I I i I i I i !I I l I II III ! II 'I ! I I I i� I 11 I.II ii i II II I r I I II I I I I i [ I iII I i I I I I I I I I. I i i I I t ( I ! I I! I ! I I I I I I I I ! I I I I I I iII' I I it I I' II I I I I I I I I I I III I I 1 i I I i ! I i I II I f I I I! I I I I i i ! i I! I I I! i i I I i i I I I I: I I !! ! I ! i I 11 i I I I 1 i l I i I I i f I I ! i I I I l i I I I{ II Ili ii I I I I I 'I t I I I i I I I I 1 1 I ! I ! I: .I;'i I II I II ! ,i I I• I 11' t u I I I I I I i l i. ! I i I I ( I I I ! I I I I IIi I ! 11 I '• I•. I i I' I ! II I I I I ! II I IIII I (• I i 'I I !! I I II I I it i I I 11 I I' it 'I i li II 'j I I I I i ! i ( ; I i I jII'I I I i I I I ! I: it i ! I ii I I .I II I I I !•� I I I. I I it I I ; it I I I i I I I I I I I I ,; I{ it I I I "I I 11 ! ?i I I II �i I I i i I i I j i I i I I I I i I I I I I I I I III III ; ;I,j II i I I i i li II ! ! I I I I I I I I I I ! I I I I I I I I I I I I I I' .I I i I 'i I I I; I I I I I I I I I I i I I I I I I I I i I I IIII II+ I I I I I i I I I! I' i I ' . i I i I II !! l i i i I I, ! I I I I ' I! li i I I � I I 'I !,�i I I i I !I I I I II i it I I ! i I i II I I i I I i I I II I II I I I i I i I II I II I I I I I I I ( i I s ! I ll ; I ; I I I I ,I I I I I I j , I III I I I ; , I I ; I i I• I: it ; I! I I I i' ( I ii it I I i i I I 11 •, it I i! I I i i i! I I '! I, is 1 I , II I I. i ! I I I I I , , I ! I I ; i I I . !! I II I. II I Ili ! I l ! I I li I• III Ii I i ! I II i i i ! I I i I ! I i I ! I I i I I li it 1 !! I ! I I I'I II I I I I .1�.��.... I I ll I i I I ; I I I I I ! I I I i I. i I I I I 'I !I I i i t z .R/F 99 w o ETR DN +' -_ ETR �V 15cd ETR ETR ETR ETR �j 15cd ETR 1 cd 117 RESTR 116 VEST. 112 PRO SHOP ETR 115 1*AEN LIFE SAFETY IN THIS AREA �, m f IS EXISTING TO REMAIN. p/ STOR. ' \\ 1 114 11 f `Ri VEST. Y/110 _. I BOWLING AREA 123 ETR ECH, 109 1 WOMEN P�� I - 1111E 4 ` Q ETR T� R/F ETR ETR ETR" _-. R/F 15cd. ELECTRICAL - LIFE SAFETY PLAN SCALE:1/8" =1'-0" 0 870" 16'-0" 24'-011 ETR R/F ETR ETR ,pi ETR 15cd ETR ETR ETR KITCHEN i 105 ENTRY/ ETR RECEPTION 101 WALK-IN COOLER 106 ETR 'R/F BAR AREA ETR ETR 103 KITCHE 107 ' R/F _SHOE ROOM 102 ETR PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 J V J �0 M O o N CJ o U LLJ Q �� -3: u DQ OU Lu m 0 03 uCJ 10 O �t N W uo ♦^ � D 'ITv ,^ - 0 0 W W u- z UNN N z �Z-� LL_I Z N W U 00 0 N � Q — a. - aik U a00 M O � 00 O U a 00 STAMP: Sri ��♦i+�Rri#i#i,��l� �� r ' + ~ F a F•. ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: SB CHECKED BY: MD DRAWING TITLE: ELECTRICAL - LIFE SAFETY PLAN DRAWING NUMBER: El • 2 EQUIPMENT WIRING SCHEDULE AMPACITY WIRE AND CONDUIT SIZE 15,20 1 2#12 + 1#12 GROUND IN 3/4" CONDUIT 15,20 3 3#12 + 1#12 GROUND IN 3/4" CONDUIT 25,30 1 2#10 + 1#10 GROUND IN 3/4" CONDUIT 25,30 3 3#10 + 1#10 GROUND IN 3/4" CONDUIT 35,40 1 2#8 + 1#10 GROUND IN 3/4" CONDUIT 35,40 3 3#8+ 1#10 GROUND IN 3/4" CONDUIT 45,50,55 1 2#6 + 1#10 GROUND IN 3/4" CONDUIT 45,50,55 3 3#6 + 1#10 GROUND IN 3/4" CONDUIT 60 1 2#4 + 1#10 GROUND IN 1" CONDUIT 60 3 3#4 + 1#10 GROUND IN 1" CONDUIT 70 3 3#4 + 1#8 GROUND IN 1" CONDUIT 80 3 3#3 + 1#8 GROUND IN 1-1/4" CONDUIT 90 3 3#2 + 1#8 GROUND IN 1-1/4" CONDUIT 100,110 3 3#1 + 1#6 GROUND IN 1-1/4" CONDUIT 125,150 3 3#1/0 + 1#6 GROUND IN 1-1/2" CONDUIT 175 3 3#2/0 + 1#6 GROUND IN 2" CONDUIT 200 3 3#3/0 + 1#4 GROUND IN 2" CONDUIT NOTE: 1. THE AMPERAGE AND PHASE OF THE WIRING ON THIS SCHEDULE CORRESPONDS TO THE CIRCUIT BREAKER SIZE IN THE ELECTRICAL CONNECTION SCHEDULE FOR MECHANICAL EQUIPMENT. PROVIDE WIRING AS INDICATED UNLESS OTHERWISE SPECIFIED. 2, WIRE SIZE IS BASED ON THE USE OF COPPER CONDUCTORS. FIRE STOPPING NOTES LIGHT FIXTURE SCHEDULE TYPE FIXTURE DESCRIPTION MANUFACTURER CATALOG NO. MOUNTING LAMPING VOLTAGE DESCRIPTION/REMARKS TYPE WATTAGE A 6" DOWNLIGHT (TO BE SELECTED) - RECESSED LED - 120 6" RECESSED LED DOWNLIGHT B 6" PENDANT (TO BE SELECTED) - PENDANT LED - 120 6" DECORATIVE PENDANT LIGHT C 8' LED STRIP (TO BE SELECTED) - RECESSED LED - 120 8' LED STRIP LIGHT D 2'x4' LIGHT FIXTURE (TO BE SELECTED) - RECESSED LED - 120 2'x4' RECESSED LED LIGHT E ACCENT LIGHT (TO BE SELECTED) - WALL LED - 120 3ECORATIVE WALL MOUNTED PENDANT ACCENT LIGHT F PENDANT FIXTURE (TO BE SELECTED) - PENDANT LED - 120 LARGE DECORATIVE PENDANT LIGHT G DIRECTIONAL DOWNLIGHT (TO BE SELECTED) - RECESSED LED - 120 6" RECESSED LED DIRECTIONAL DOWNLIGHT NOTES: 1. PROVIDE ACCESSORIES AND MOUNTING HARDWARE AS REQUIRED FOR ALL LIGHT FIXTURES. 2. FIXTURE/ACCESSORY COLORS NOT INDICATED ON THE DRAWINGS SHALL BE SELECTED BY ARCHITECT. 3. PROVIDE LAMPING FOR ALL FIXTURES UNLESS LAMPING IS INCLUDED WITH FIXTURE. 4. PROVIDE TYPICAL MOCK-UP FOR LIGHT FIXTURE HANGING HEIGHTS AND EXPOSED ELECTRICAL CONDUIT LAYOUT TO BE REVIEWED BY ARCHITECT. 5. ALL LIGHT FIXTURES WITH INCANDESCENT OR FLOURESCENT LAMPING SHALL BE PROVIDED WITH A COMPATIBLE LED LAMP. 6. COLOR AND FIN ISH OF ALL LIGHT FIXTURES SHALL BE APPROVED BY OWNER/ARCHITECT PRIOR TO THE SUBMITTAL OF SHOP DRAWINGS. 1. GENERAL: FIRE STOPPING SHALL BE PROVIDED BY THIS CONTRACTOR FOR ALL FLOOR, CEILING AND FIRE RATED WALL PENETRATIONS FOR CONDUIT, SLEEVES AND/OR CABLING AS REQUIRED BY JOB CONDITIONS. 2. THE CONTRACTOR SHALL PROVIDE A FIRE STOP SYSTEM IN ACCORDANCE WITH THE FOLLOWING: 2.1. THE SYSTEM SHALL CONSIST OF A WATER BASED SEALANT AND SUITABLE DAMMING MATERIALS (WHERE REQUIRED) AND BE INSTALLED PER MANUFACTURER'S REQUIREMENTS. 2.2. THE SEALANT SUPPLIED SHALL BE A TWO STAGED INTUMESCENT AND CAPABLE OF EXPANDING UP TO 8 TIMES ITS ORIGINAL VOLUME. 2.3. THE SEALANT SUPPLIED SHALL CONTAIN NO ASBESTOS, NO FIBERGLASS, AND NO SOLVENTS NOT CORROSIVE MINERAL SALTS OF ANY KIND. 2.4. THE SEALANT SHALL FORM A SURFACE CAPABLE OF BEING SANDED AND PAINTED TO MATCH SURROUNDING SURFACES AND SHALL BE IMPERVIOUS TO WATER WHEN DRY. 2.5. THE FIRE STOP SYSTEM SHALL BE TESTED TO THE TIME/TEMPERATURE REQUIREMENTS OF ASTM E119 AND SHALL BE UL1479 (ASTM E814) AND CLASSIFIED FOR UP TO 3 HOURS. 2.6. THE FIRE STOP SEALANT SHALL BE SPECSEAL SEALANT AS MANUFACTURED BY SPECIFIED TECHNOLOGIES, INC. OR APPROVED EQUAL. 2.7. SPECIAL CARE SHALL BE TAKEN WITH ELECTRICAL SYSTEMS NOT TO COMPROMISE ANY OF THE BUILDING FIRE PARTITIONS, FLOORS, WALLS OR MEMBRANES. PROVIDE ALL FIRESTOPPING REQUIRED TO COMPLY WITH THE BUILDING CODE, THE ELECTRICAL CODE AND THE UL LISTING OF EACH ASSEMBLY. COORDINATE LOCATIONS AND TYPES OF MEMBRANES WITH ARCHITECT. SEISMIC RESTRAINT NOTES 1, GENERAL: IT IS THE INTENT OF THIS SEISMIC SPECIFICATION TO KEEP ALL ELECTRICAL BUILDING SYSTEM COMPONENTS IN PLACE DURING A SEISMIC EVENT. ALL ELECTRICAL SYSTEMS MUST BE INSTALLED IN STRICT ACCORDANCE WITH SEISMIC CODES, COMPONENT MANUFACTURER'S AND BUILDING CONSTRUCTION STANDARDS. WHENEVER A CONFLICT OCCURS BETWEEN THE MANUFACTURER'S OR CONSTRUCTION STANDARDS, THE MOST STRINGENT SHALL APPLY. 2. THIS CONTRACTOR SHALL ENGAGE A PROFESSIONAL STRUCTURAL ENGINEER REGISTERED IN THE JURISDICTION OF THIS PROJECT TO REVIEW THE ENTIRE INSTALLATION TO DETERMINE ALL SEISMIC RESTRAINT REQUIREMENTS AND METHODS. CONTRACTOR SHALL SUBMIT A REPORT OUTLINING THE STRUCTURAL ENGINEER'S REVIEW AS WELL AS SEISMIC RESTRAINT SHOP DRAWINGS AND SUPPORTING CALCULATIONS PREPARED BY THE PROFESSIONAL STRUCTURAL ENGINEER FOR REVIEW BY THE ARCHITECT. 3. SEISMIC RESTRAINTS SHALL BE DESIGNED IN ACCORDANCE WITH SEISMIC FORCE LEVELS AS DETAILED IN THE APPLICABLE BUILDING CODE. 3.1. ALL EQUIPMENT, CONDUITAND PULL BOXES SHALL BE ADEQUATELY RESTRAINED TO RESIST SEISMIC FORCES. RESTRAINT DEVICES SHALL BE DESIGNED AND SELECTED TO MEET SEISMIC REQUIREMENTS AS DEFINED IN THE LATEST ISSUE OF THE BOCA NATIONAL BUILDING CODE IN ACCORDANCE WITH THE APPLICABLE SEISMIC ZONE. 3.2. ANCHOR BOLT CALCULATORS, SIGNED AND STAMPED BY A REGISTERED PROFESSIONAL ENGINEER, SHALL BE SUBMITTED SHOWING ADEQUACY OF THE BOLT SIZING AND TYPE, STAMPED CALCULATIONS SHALL ALSO BE FURNISHED FOR ANCHORS ON RESTRAINT DEVICES, CABLES, ISOLATORS AND RIGIDLY MOUNTED EQUIPMENT. INSTALLED EVERY 25 DEVICES PANELBOARD: LP1 AI C : 100, 000 BUS RATING: 1225A I 225 A, 208Y1120 V, 3 PH, 4 W, 60 HZ MAIN LUG ONLY MAIN CIRCUIT BREAKER X FLUSH MOUNTEDB SURFACE MOUNTED X NOTES: LC = VIA LIGHTING CONTROL PANEL G = GFCI - 5mA TRIP P = GFPE - 30 mA TRIP S = SHUNT TRIP L = PROVIDE LOCK ON CB SHUNT TRIP MAIN 200% RATED NEUTRAL ISOLATED GROUND FEED THRU LUGS 100% RATED MAIN BREAKER GROUND FAULT MAIN C.B. CKT No. LOAD Note WIRE SIZE CIRCUIT BREAKERS CKT No. LOAD Note WIRE SIZE CIRCUIT BREAKERS o N Q m m U U o p w W U-(9 U- (� o N m m m U v 0 p p p w w w U- LL u— C9 (� 1 LIGHTING 1 2 LIGHTING 1 3 LIGHTING 1 4 LIGHTING 1 5 LIGHTING 1 6 LIGHTING 1 7 LIGHTING 1 8 LIGHTING 1 9 LIGHTING 1 10 RECEPTACLES 1 11 RECEPTACLES 1 12 ARCADE 1 13 ARCADE 1 14 ARCADE 1 15 ARCADE 1 16 ARCADE 1 17 ARCADE 1 18 DESK 1 19 RECEPTACLES 1 20 SPARE 21 SPARE 22 SPARE 23 SPARE 24 SPARE 25 SPARE 26 SPARE 27 SPARE 28 SPARE 29 SPARE 30 SPARE 31 SPARE 32 SPARE 33 SPARE 34 SPARE 35 SPARE 36 SPARE 37 SPARE 38 SPARE F39 SPARE 40 SPARE 41 SPARE 42 SPARE Im F �T L kSD CM CM SD D Sp D kSD kSD RTS RTS ( — _ 24V WIRING I 2 � TO ADDITIONAL �? DEVICES IM CM IM I F F F F �B EXISTING 177cd 177cd 75cd 75cd — ( 1 FIRE ALARM POWER SUPPLY ( 1 EXISTING I �' AP7S] (TYP.) ADDRESSABLE — MAI N L 20AJ1 P FIRE ALARM � �120V CONTROL PANEL. I � � 3 CAC �► iti 20A/1P _ 120-V/ i O1 ALL STROBES SHALL BE SYNCHRONIZED. EXACT METHOD FOR SYNCHRONIZATION SHALL BE SPECIFIC TO EACH FIRE ALARM MANUFACTURER. PROVIDE EVIDENCE OF SYNCHRONIZATION IN FIRE ALARM SUBMITTAL. 20 PROVIDE ISOLATION MODULES AT EITHER SIDE OF FIRE ALARM MODULES FOR BOOSTER PANELS AND MASTER BOX, TYPICAL, OPARTIAL FIRE ALARM RISER DIAGRAM SCALE: N.T.S. FIRE ALARM SYSTEM GENERAL NOTES: 1. ALL WIRING SHALL BE PER MANUFACTURER'S SPECIFICATIONS. 2. THIS SCHEMATIC IS TYPICAL. WIRE TO ALL DEVICES ON ALL LOOPS AND CIRCUITS. SEE PLAN VIEWS FOR TYPES AND QUANTITIES OF DEVICES. 3. ALL FIRE ALARM WIRING SHALL BE RUN CONTINUOUS FROM DEVICE TO DEVICE. (SEE RIUFC). 4. OUTGOING AND RETURN CONDUCTORS MUST BE RUN IN SEPARATE RACEWAYS. PROVIDE MINIMUM SEPARATION OF 1 FOOT WHERE THE CABLE IS RUN VERTICALLY AND A 4 FEET SEPARATION WHERE THE CABLE IS RUN HORIZONTALLY. (SEE RIUFC AND NFPA). 5. PROVIDE ANY ADDITIONAL REMOTE POWER SUPPLIES AS NECESSARY, PROVIDE ADDITIONAL SMOKE DETECTORS AS NECESSARY PER NFPA. 6. PROVIDE INTERMEDIATE RELAYS AS NEEDED. 7. SYNCHRONIZE ALL STROBE LIGHTS. 8. VERIFY WIRING TYPE FOR INITIATING LOOP. 9. VERIFY ADDITIONAL WIRING (e.g. 24V POWER FOR MODULES) WITH SPECIFIED MANUFACTURER. 10. PROVIDE NEW FIRE ALARM POWER SUPPLIES, DEVICES, WIRING, ETC, AS REQUIRED TO SERVE NEW FIRE ALARM NOTIFICATION DEVICES SHOWN ON THE DRAWINGS. 11. PROVIDE ISOLATION MODULES AS REQUIRED IN ACCORDANCE WITH THE RHODE ISLAND FIRE SAFETY CODE. PROVIDE AN ISOLATION MODULE FOR EVERY 25 INITIATING DEVICES. 12. PROVIDE 25% SPARE CAPACITY ON INITIATIONS AND NOTIFICATIONS LOOPS. 13. ALL FIRE ALARM EQUIPMENT INCLUDING AND NOT LIMITED TO FIRE ALARM PANELS, CABINETS, ANNUNCIATOR, PULL STATIONS, ETC. SHALL BE LOCKABLE TYPE. PROVIDE KEY ALIKE LOCKABLE EQUIPMENT AS REQUIRED. PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 Ln 0 M O O cv U _.J o U WQLU �Q _J 06 ck� D Lu m 3: O10 x0 � O d u 10M 10 w L. F- � v = �C) r /J � �0; 0 ■� ,n �� z w. (v) me � N z er Z N w U CO Q o C'4 L0 co rL. a� c� N OMO 4 i O • F* M M U p 00 00 N O oo �VM STAMP: x,v. y L i �c r� rro4,�. ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: SB CHECKED BY: MD DRAWING TITLE: ELECTRICAL - SCHEDULES DRAWING NUMBER: E260 1. DATA CABLING SHALL BE PLENUM RATED CATEGORY 6 EQUAL TO BELDEN #3612. COLOR PER OWNERS REQUIREMENTS. 2. CABLING SHALL BE TERMINATED IN THE ASSOCIATED SERVICE BRANCHES STORAGE ROOM ON A WALL MOUNTED 48 PORT PATCH PANEL. 3. LABELING PER OWNERS REQUIREMENTS. 4. FACEPLATES SHALL BE WHITE THERMOPLASTIC WITH ID LABELS. 2 PORT U O[TELECOMMUNICATION FACEPLATE DETAIL r RECEPTACLE. LEVITON IEL #6898-1 WITH LED :ATOR LIGHT OR EQUAL. RAINTIGHT WHILE IN -USE ENCLOSURE. LEVITON MODEL #5997-CL OR EQUAL. O � WEATHERPROOF RECEPTACLE DETAIL � -1 5 GROUND PAD ASSEMBLY BOND TO BUILDING GROUND PRESSURE RING -T SI RUC] UKE NOTES: 1. USE WATERTIGHT CONDUIT SEAL WHERE CONDUIT PENETRATIONS OF BUILDING EXTERIOR WALLS ARE BELOW GRADE AND FOR TUNNEL PENETRATIONS. 2. ADJUSTABLE GLAND LOCATED WHERE ACCESSIBLE. BODY CONCRETE WALL =RSIZE EVE gDUIT OF SIRUCIURE Q ONDUIT PENETRATION DETAIL � ELECTRICAL MAIN GROUND BUS FROM SERVICE GROUND (NOTE #1) BUILDING STEEL (NOTE #1) EMGB WATER SERVICE VALVES WM (NOTE #1) CADWELD, TYPICAL. REBAR, OR AS REQUIRED ROUND CLAMPS, PER NEC 250. ACROSS WATER METER. GROUND JUMPER �o (NOTE #1) y0 _1 NOTE #1) (NOTE #1) 10'-0" "X10'-O" COPPERWELD )UND ROD (TYPICAL) NOTES: 1. WIRING SHALL CONSIST OF: 1#1/OG, 1"C. 2. LOCATE GROUND RODS IN ANY ARRANGEMENT TO AVOID OBSTRUCTIONS, BUT MAINTAIN 25'-0" MINIMUM SEPARATION AND MEET APPROVAL OF OWNER. 3. TAKE EVERY POSSIBLE PRECAUTION TO AVOID UNDERGROUND UTILITIES, REVIEW ALL AVAILABLE DRAWINGS AND CONTACT "DIG SAFE", PRIOR TO CONSTRUCTION. 4. E.C. SHALL BE RESPONSIBLE TO ENSURE THAT GROUND RESISTANCE IS LESS THAN OR EQUAL TO 10-OHMS. E.C. SHALL SUPPLEMENTAL GROUNDING ELECTRODES AS NECESSARY TO ESTABLISH 10-OHMS (MINIMUM) RESISTANCE TO GROUND. 5. GROUNDING & BONDING SHALL BE INSTALLED IN ACCORDANCE WITH NEC (2017), ARTICLE 250. O � GROUNDING GRID DETAIL � CEILING MOUNTED OCCUPANCY SENSOR CEILING MOUNTED SMOKE DETECTOR A/C j7 SEE NOTE 7 DIFFUSER PROVIDE PENDANT WHERE REQUIRED 71-6" EXIT EXIT SIGN 61811 (MIN.) FIRE ALARM AUDIO/-- _ PANELBOARD 6'4" VISUAL DEVICE -' WALLTELEPHONES SEE NOTE 6 l 4'-6" I' 4'-0" u u COUNTER; SEE NOTE 4 11ral 3 -8 FIRE ALARM i ©i ®0 BACKSPLASH -- SEE PULL STATION � _ NOTE - =, 2'-3" 8 SWITCHES -_- RECEPTACLE AREA OF CANE DETECTION i ,I liu i TELECOMMUNICATION OUTLETS j L FINISHED FLOOR NOTES: 1. DEVICE LOCATIONS AND MOUNTING HEIGHTS SHALL BE CHECKED AGAINST THE ARCHITECTURAL PLANS AND ELEVATIONS PRIOR TO ROUGH -IN IN ORDER TO AVOID INTERFACES WITH CASEWORK, FURNITURE, WINDOWS, MIRRORS, EQUIPMENT, ETC. 2. LOCATIONS OF OUTLETS AND EQUIPMENT AS INDICATED ON THE DRAWINGS ARE APPROXIMATE. THE EXACT CENTER OF ALL OUTLETS SHALL BE PLACED IN COOPERATION WITH THE GENERAL CONTRACTOR AND ARCHITECT. CONTRACTOR SHALL EXAMINE ALLTHE EXTERIOR DETAILS OF THE CONSTRUCTION DRAWINGS FOR OUTLET LOCATIONS NOT CONFORMING TO THE DETAIL ABOVE. WHERE DETAILED TO SPECIFIC LOCATIONS, THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE. IF AN OUTLET IS INSTALLED IN SUCH A LOCATION AS TO BE OUT OF PROPER RELATION TO BE CORRECTED BY AT THE EXPENSE OF THE CONTRACTOR UNDER THE DIRECTION OF THE ARCHITECT OR ENGINEER. 3. DEVICES SHALL BE CENTERED IN A COMMON VERTICAL PLANE. HEIGHT SHALL BE MEASURED FROM FINISHED FLOOR TO CENTERLINE OF DEVICE EXCEPT EXIT SIGNS, AND FIRE ALARM SIGNALS. COORDINATE LOCATIONS WITH MATERIALS SUCH AS MASONRY UNITS. 4. REFER TO THE ARCHITECTS ELEVATION DETAILS FOR EXACT MOUNTING HEIGHT AND LENGTH OF SURFACE RACEWAYS. RECEPTACLE MOUNTING HEIGHT ABOVE COUNTERS SHALL BE COORDINATED WITH CASEWORK HEIGHTS. 5. PROTRUDING OBJECTS CANNOT REDUCE THE MINIMUM WIDTH OF ACCESSIBLE ROUTES. 6. 4" MAX PROTRUDING FROM WALL FOR CANE. 7. OBJECTS ABOVE HEAD ROOM CLEARANCE (MIN. OF 7'-6") CAN PROTRUDE ANY AMOUNT. 8. OBJECT WITH LEADING EDGES WITHIN CANE SWEEP CAN PROTRUDE ANY AMOUNT. ® TYPICAL DEVICE MOUNTING HEIGHTS DETAIL ELECTRICAL CONTRACTOR SHALL PROVIDE ENGRAVED COVERPLATES TO INDICATE PANEL NAME AND CIRCUIT NUMBER. (TYP) NOTE: 1. GENERAL RECEPTACLES AND COVERPLATES SHALL BE WHITE IN COLOR, UNLESS OTHERWISE INDICATED. O � TYPICAL RECEPTACLE LABELING DETAIL I ACCESSIBLE CEILING TERMINATE WITH INSULATED THROAT BUSHING. - 1" EMT. PROVIDE RANDL INDUSTRIES OR EQUAL 5" SQUARE BOX, 2-7/8" DEEP W/ INTEGRAL CABLE MANAGEMENT AND SINGLE GANG RAISED COVER NOTES: 1. COORDINATE ROUGH -IN REQUIREMENTS WITH OWNER'S TELECOMMUNICATIONS VENDOR PRIOR TO START OF ANY WORK. 2. PROVIDE NYLON PULL STRING IN ALL EMPTY RACEWAYS. 3. PROVIDE ACCESSIBLE PULL BOXES, SIZED PER TIA STANDARDS, AS NEEDED. ® TELECOMMUNICATIONS CONDUIT DETAIL PROVIDE A FULL TIA COMPLIANT RACEWAY SYSTEM (TYP) 1" EMT TO 12" ABOVE FINISHED SUSPENDED CEILING. EMT SHALL BE FULLY CONCEALED IN FINISHED WALL. FINISHED WALL STRUCTURAL OVERHEAD I, NO PIPING OR DUCTWORK SHALL .. BE INSTALLED WITHIN THE SPACE _ DIRECTLY ABOVE ELECTRICAL PANELS OR SWITCHGEAR \ / ELECTRICAL PANEL ELECTRICAL PANEL WORKSPACE AS DEFINED BY THE WALL NATIONAL ELECTRIC CODE / \ NO PIPING OR DUCTWORK SHALL \ , BE INSTALLED WITHIN THE ELECTRICAL PANEL WORKSPACE FLOOR O � ELECTRICAL/MECHANICAL EQUIPMENT COORDINATION KEYED DETAIL NOTES: �1 TO LOCAL UNSWITCHED LIGHTING CIRCUIT SERVING THE AREA. CONCEAL ALL WIRING. 2� HARD WIRE TO JUNCTION BOX (DO NOT PLUG IN). �3 BATTERY UNIT. SEE SPECIFICATIONS. SIZE UNIT TO HANDLE FULL LOAD FOR 1 1/2 HOURS TO 87 1/2% OF VOLTAGE OR PROVIDE ADDITIONAL UNITS TO ACCOMPLISH THIS. MOUNT SO THAT IT CAN BE READILY MAINTAINED AND TESTED. O TO DEDICATED UNSWITCHED EXIT SIGN CIRCUIT. CONCEAL ALL WIRING. ® I EMERGENCY BATTERY SCHEMATIC 0 0 PANELBOARD: 100A 208Y/120V 1/4" LETTERS (TYP) FED FROM 0 0 NOTES: 1. NAMEPLATES SHALL BE FURNISHED AND INSTALLED ON THE METER CENTERS/SWITCHBOARD AND METER CENTERS/SWITCHBOARD CIRCUIT BREAKERS, PANELBOARDS, TRANSFORMERS, JUNCTION BOXES, CABINETS FOR ALL SPECIAL PURPOSE SWITCHES, MOTOR DISCONNECT SWITCHES, STARTERS AND OTHER CONTROLS FURNISHED UNDER THIS CONTRACT, TO DESIGNATE THE EQUIPMENT CONTROLLED AND FUNCTION. 2. NAMEPLATES SHALL BE LAMINATED WHITE BAKELITE WITH 1/4" HIGH BLACK RECESSED LETTERS. 3. NAMEPLATES SHALL BE SECURELY ATTACHED TO THE EQUIPMENT WITH GALVANIZED SCREWS OR RIVETS. 4. ADHESIVES OR CEMENTS WILL NOT BE PERMITTED. 10 TYPICAL PANELBOARD NAMEPLATE DETAIL PROJECT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 J Lo0 O o cv U o� U Lu QLU u�< �Q 06 1:4o Lu co 0 03 M 10 o v w� F L0 _ ITV) r n IT v I ,o Lu U wC � N �N z J^ Z 1- LPL w Lu L CO U o (V L0 Q < 11 ia a� ¢� U U O'\ ct ono `(+�N-r) • ^�, rn M M M `-' V/ N���kn� O M kn 1.�I • tf) r. � © Ooo00 pU 2 o , M �V 00 STAMP: 44010 I N L y TAT F ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: SB CHECKED BY: MD DRAWING TITLE: ELECTRICAL - DETAILS DRAWING NUMBER: 3,o 0 I- off- �� - - �� I - - - - ,..: _TTTu1�h l l,l � .I I_.. I i.- .. i,n ,�.�,�,. u. IiL. .i... �., I:.II. I-i. L. _il �_J.'..I J. � �� �T���� i i I (� i � I I. �.. � t� I .L. � I_ �. �.� �I ELECTRICAL SPECIFICATIONS: PART 1- GENERAL 1.1. GENERAL REQUIREMENTS: ALL WORK SHALL BE IN ACCORDANCE WITH THE ARRANGEMENT, DETAILS AND LOCATION AS INDICATED ON THE CONTRACT DOCUMENTS, REFERENCE DRAWINGS AND ANY SUPPLEMENTAL ADDENDA, BULLETINS OR DRAWINGS ISSUED BY THE ARCHITECT/ENGINEER. LAYOUTS ARE DIAGRAMMATIC AND FINAL ARRANGEMENT OF EQUIPMENT SHALL SUIT FIELD CONDITIONS. REFER TO ALL DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THIS PROJECT FOR THE EXACT LOCATION OF ALL EQUIPMENT AND REQUIRED MOUNTING HEIGHTS PRIOR TO THE START OF ANY ROUGHING. THE RIGHT IS RESERVED TO MAKE ANY REASONABLE CHANGE IN LOCATION TO OUTLETS AND EQUIPMENT PRIOR TO ROUGHING AT NO ADDITIONAL EXPENSE TO THE OWNER. 1.2. SCOPE OF WORK: THE SCOPE OF WORK CONSISTS OF THE INSTALLATION OF ALL MATERIALS TO BE FURNISHED UNDER THIS SECTION, AND WITHOUT LIMITING THE GENERALITY THEREOF, CONSISTS OF FURNISHING ALL LABOR, MATERIALS, EQUIPMENT, STORAGE, TRANSPORTATION, RIGGING, STAGING, APPURTENANCES AND SERVICES NECESSARY AND/OR INCIDENTAL TO PROPERLY COMPLETE ALL ELECTRICAL WORK SHOWN ON THE DRAWINGS, AS DESCRIBED IN THE SPECIFICATIONS, OR AS REASONABLY INFERRED FROM EITHER, IN THE OPINION OF THE ARCHITECT/ENGINEER AS BEING REQUIRED. 1.3. SITE VISIT: BIDDERS ARE ADVISED TO VISIT THE SITE AND INFORM THEMSELVES AS THE TO CONDITIONS UNDER WHICH THIS WORK WILL BE PERFORMED. FAILURE TO DO SO WILL, IN NO WAY, RELIEVE THE SUCCESSFUL BIDDER FROM THE RESPONSIBILITY OF FURNISHING ANY MATERIALS OR PERFORMING ANY WORK IN ACCORDANCE WITH THE TRUE INTENT AND MEANING OF THE DRAWINGS AND SPECIFICATIONS. NO COMPENSATION WILL BE GRANTED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY AN EXPERIENCED OBSERVER. FIELD VERIFY MEASUREMENTS AND CIRCUITING ARRANGEMENTS THAT ARE SHOWN ON DRAWINGS. ARRANGEMENTS SHALL BE MADE WITH THE OWNER PRIOR TO THE VISIT FOR INSPECTION F THE WORK 0 WO AREA(S). 1.4. RELATED WORK: 1. THE FOLLOWING RELATED WORK IS NOT INCLUDED UNDER THIS SECTION AND SHALL BE PROVIDED UNDER OTHER SECTIONS. C COORDINATE WITH OOR ALL DIVISIONS TO ENSURE A COMPLETE INSTALLATION: A. CUTTING AND PATCHING. B. ALLOWANCES. C. ALTERNATIVES. D. MAGNETIC DOOR RELEASE. E. ACCESS PANELS. F. MAGNETIC LOCK. 1.5. DEFINITIONS: A. "CONCEALED" SHALL BE DEFINED AS AREAS WHERE CONDUIT AND WIRING IS LOCATED IN CHASES, WALLS, PARTITIONS, SHAFTS, AND ABOVE FINISHED CEILINGS. B. "EXPOSED" SHALL MEAN CONDUIT AND WIRING RUN ON THE SURFACE OF THE BUILDING CONSTRUCTION. C. "CONDUIT" SHALL MEAN IN ADDITION TO CONDUIT, ALL FITTINGS, HANGERS AND OTHER ACCESSORIES RELATING TO SUCH CONDUIT SYSTEMS. D. "WIRING" SHALL MEAN WIRE, RACEWAY, BOXES AND FITTINGS. E. "PROVIDE" SHALL MEAN "PROVIDED COMPLETE IN PLACE" THAT IS, "FURNISHED AND INSTALLED." 1.6. CODES, REGULATIONS, AND PERMITS: ALL WORK UNDER THIS SECTION SHALL CONFORM TO THE LATEST EDITIONS OF THE LOCAL STATE BUILDING CODE, THE STATE ELECTRICAL CODE, NFPA, ANSI/NECA INSTALLATION STANDARDS, AND ALL OTHER LOCAL GOVERNING CODES. GIVE NOTICES, FILE PLANS, OBTAIN AND PAY FOR PERMITS AND LICENSES AND OBTAIN NECESSARY APPROVALS FROM AUTHORITIES HAVING JURISDICTION. PERMITS SHALL BE SECURED THROUGH THE CITY. DELIVER CERTIFICATES OF INSPECTIONS TO ARCHITECT/ENGINEER. NO WORK SHALL BE COVERED BEFORE EXAMINATION AND APPR OVAL ROVAL BY ARCHITECT ENGINEER AND THE AUTHORITIES HA VING JURISDICTION. IMPERFECT OR CONDEMNED WORK SHALL B REPLACED WITH E PLACE WORKING CONFORMING TO REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER, SUBJECT TO APPROVAL OF THE ARCHITECT/ENGINEER. IF WORK IS COVERED BEFORE DUE INSPECTION AND APPROVAL THE ELECTRICAL CONTRACTOR SHALL PAY COSTS OF UNCOVERING THE INSTALLED WORK, WHETHER IT MEETS CONTRACT REQUIREMENTS OR NOT. 1.7. MATERIAL S: ALL MATERIALS AND EQUIPMENT FURNISHED UNDER THIS SECTION SHALL BE NEW AND OF THE BEST GRADE FOR THE SERVICE INTENDED. IT IS NOT INTENDED THAT THESE SPECIFICATIONS OR DRAWINGS SHOW EVERY CONDUIT, FITTING, AND APPURTENANCE. ALL SUCH PARTS NECESSARY FOR THE COMPLETE EXECUTION OF THE WORK, IN ACCORDANCE WITH THE BEST PRACTICES OF THE TRADE AND TO THE SATISFACTION OF THE ARCHITECT/ENGINEER SHALL BE PROVIDED WHETHER THESE PARTS MAY HAVE SPECIFICALLY MENTIONED OR NOT, OR INDICATED ON THE DRAWINGS. 1.8. SHOP DRAWINGS: WHERE THE DRAWINGS OR SPECIFICATIONS LIST SPECIFIC BRANDS OR CATALOG NUMBERS, ONLY THESE PRODUCTS MAY BE USED UNLESS THE WORDS: "OR APPROVED EQUAL" OR "BUT ARE NOT LIMITED TO" ARE INCLUDED, THE ENGINEER'S REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN INTENT. MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE ELECTRICAL CONTRACTOR FROM COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS, NOR DEPARTURES THEREOF. THE ELECTRICAL CONTRACTOR REMAINS RESPONSIBLE FOR DETAILS AND ACCURACY, FOR CONFORMING AND CORRECTNESS OF ALL QUANTITIES AND DIMENSIONS, FOR SELECTING FABRICATING PROCESSES, FOR TECHNIQUES OR ASSEMBLY, AND FOR PERFORMING THEIR WORK IN A SAFE MANNER. DEVIATIONS TO SPECIFIED MATERIALS SHALL BE AT THE SOLE RISK OF THE ELECTRICAL CONTRACTOR, WHO SHALL BE RESPONSIBLE FOR ALL ASSOCIATED CHANGES TO THIS AND OTHER TRADES. WITHIN THIRTY (30) DAYS AFTER THE DATE OF NOTICE TO PROCEED, AND BEFORE THE PROCUREMENT OF ANY MATERIALS AND EQUIPMENT, SUBMIT FOR APPROVAL A COMPLETE ITEMIZED LIST OF ALL THE MATERIALS AND SHOP EQUIPMENT INCORPORATED UNDER THIS SECTION. A Q 0 LS DRAWING SUBMITTALS SHALL BE COMPLETE AND INCLUDE ALL PART 2 PRODUCTS AND VFDS OF THIS SPECIFICATION AND BE CLEARLY IDENTIFIED. NO CONSIDERATION WILL BE GIVEN TOP PARTIAL SUBMITTALS EXCEPT WITH PRIOR APPROVAL. AR X 0 AL. 1.9. OPERATIONS AND MAINTENANCE MANUALS: 1. AT LEAST TWO (2) WEEKS PRIOR TO THE TIME OF TURNINGOVER HIS CONTR ACT TO THE OWNER FOR USE AND OCCUPANCY OR SUBSTANTIAL COMPLETION, SECURE AND DELIVER TO THE ARCHITECT/ENGINEER THREE (3) COMPLETE INDEXED BOUND FILES CONTAINING APPROVED OPERATING AND MAINTENANCE MANUALS, SHOP DRAWINGS, AND OTHER DATA AS FOLLOWS: A. OPERATION DESCRIPTION OF ALL SYSTEMS. B. COMPLETE SHOP DRAWINGS OF ALL EQUIPMENT. C. PREVENTIVE MAINTENANCE INSTRUCTIONS FOR ALL SYSTEMS. D. SPARE PARTS LISTS OF ALL SYSTEM COMPONENTS. E. NAMES, ADDRESS AND TELEPHONE NUMBERS OF ALL SUPPLIERS OF THE SYSTEMS. 2. NON -AVAILABILITY OF OPERATING AND MAINTENANCE MANUALS OR INACCURACIES THEREIN MAY BE GROUNDS FOR CANCELLATION AND POSTPONEMENT OF ANY SCHEDULED FINAL INSPECTION BY THE OWNER UNTIL SUCH TIME AS THE DISCREPANCY HAS BEEN CORRECTED AND/OR RETAINAGE OF SUFFICIENT MONIES TO PREPARE SAME. 1.10. RECORD DRAWINGS: OWNER'S RECORD DRAWINGS SHALL BE UPDATED AS THE PROJECT PROGRESSES. MAINTAIN DOCUMENTS IN SAFE, DRY LOCATION. INDICATE CLEARLY AND ACCURATELY ANY CHANGES NECESSITATED BY FIELD CONDITIONS AND DIMENSION ALL CONCEALED RACEWAYS. THE ELECTRICAL CONTRACTOR SHALL DELIVER THE COMPLETED REPRODUCIBLE RECORD DRAWINGS AND CAD DISKS PROPERLY TITLED AND DATED TO ARCHITECT/ENGINEER. THESE RECORD DRAWINGS SHALL BECOME THE PROPERTY OF THE OWNER. 1.11. CHANGE ORDERS/PROPOSAL REQUEST: A. DURING THE COURSE OF CONSTRUCTION, CHANGES IN THE WORK MAY OCCUR. WHEN A SIGNIFICANT CHANGE IS TO BE MADE, A PROPOSAL REQUEST WILL BE ISSUED. B, PROVIDE A COMPLETE COST BREAKDOWN WHEN RESPONDING TO EACH PROPOSAL REQUEST. C. EACH ITEM OF WORK TO BE PRICED SEPARATELY. D. EACH LINE ITEM TO BE BROKEN DOWN INCLUDING QUANTITIES AND LISTING SEPARATELY LABOR AND MATERIAL. 0 E. BOTH CREDITS AND EXTRAS SHALL BE SEPARATELY AND CLEARLY QUANTIFIED. F. ALLOWANCES FOR OVERHEAD AND PROFIT SHALL BE AS LISTED IN THE SUPPLEMENTARY CONDITIONS. G. IF YOU BECOME AWARE OF A FIELD CONDITION, CODE REQUIREMENT, ERROR, OR OMISSION THAT YOU FEEL SHOULD RESULT IN A CHANGE TO THE WORK, PLEASE CONTACT THE ENGINEER FOR DISCUSSION. THE ENGINEER MAY BE ABLE TO CLARIFY THE SITUATION AND AVOID UNNECESSARY PAPERWORK. H. IT IS RECOGNIZED THAT THE OWNER BENEFITS WHEN THE CONSTRUCTION PROCESS IS A COOPERATIVE EFFORT INSTEAD OF AN ADVERSARIAL RELATIONSHIP. REASONABLE GIVE-AND-TAKE ALLOWS THE CONSTRUCTION PROCESS TO MOVE SMOOTHLY. YOUR EFFORTS IN THIS REGARD WILL BE APPRECIATED BY ALL PARTIES. 1.12. GUARANTEE AND SERVICE: THE ELECTRICAL CONTRACTOR SHALL GUARANTEE THE PERFORMANCE OF THE INSTALLATION AND ALL EQUIPMENT INCLUDED IN THIS SECTION IN WRITING FOR ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE ENGINEER. SHOULD ANY DEFECTS IN MATERIALS OR WORKMANSHIP APPEAR DURING THIS PERIOD, THEY SHALL BE CORRECTED OR REPLACED BY THE ELECTRICAL CONTRACTOR TO THE SATISFACTION OF THE ARCHITECT/ENGINEER, AT NO ADDITIONAL COST TO THE OWNER. 1.13, COORDINATE WITH OTHER TRADES: CONFER WITH OTHER TRADES AND FURNISH IN WRITING TO THE ARCHITECT/ENGINEER ANY INFORMATION D NECESSARY TO PERMIT THE WORK OF ALL TRADES TO BE INSTALLE D E SATISFACTORILY AND WITH THE LEAST POSSIBLE INTERFERENCE OR DELAY. WORK INSTALLED THAT CREATED INTERFERENCE OR RESTRICTS ACCESS REQUIRED BY CODE OR TO CONDUCT MAINTENANCE AND/OR ADJUSTMENTS SHALL BE MODIFIED AT NO ADDITIONAL COST TO THE OWNER. FURNISH TO OTHER TRADES ANY INFORMATION REQUIRED FOR THE PURPOSE OF COORDINATING ADJACENT WORK. 1.14. CUTTING AND PATCHING: : I INCLUDE ALL CORING, CUTTING, PATCHING AND FIREPROOFING NECESSARY FOR THE EXECUTION OF THIS SECTION. STRUCTURAL ELEMENTS SHALL NOT BE CUT WITHOUT WRITTEN APPROVAL OF THE ARCHITECT ENGINEER. REPAIR AND P E PATCH AROUND T / A H WORK SPECIFIED HEREIN TO MATCH THE EXISTING ADJACENT SURFACES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. FILL AND PATCH ALL OPENINGS OR HOLES LEFT IN THE EXISTING STRUCTURES BYTHE REMOVAL OF EXISTING EQUIPMENT THAT IS PART OF THIS SECTION OF THE SPECIFICATIONS. APPLY FIRESTOPPING TO CABLE AND RACEWAY SLEEVES AND OTHER PENETRATIONS OF FIRE -RATED FLOOR AND WALL ASSEMBLIES TO RESTORE ORIGINAL UNDISTURBED FIRE -RESISTANCE RATINGS OF ASSEMBLIES. 1.15. HOISTING, SCAFFOLDING AND PLANKING: INCLUDE THE FURNISHING, SETUP -UP AND MAINTENANCE OF ALL HOISTING MACHINERY, CRANES, SCAFFOLDS, STAGING AND PLANKING AS REQUIRED FOR THE EXECUTION OF WORK FOR THIS SECTION. 1.16. SAFETY REQUIREMENTS: LIFE SAFETY AND ACCIDENT PREVENTION SHALL BE A PRIMARY CONSIDERATION. COMPLY WITH ALL SAFETY REQUIREMENTS OF THE OWNER AND OSHA THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD OF THE PROJECT. FURNISH, PLACE AND MAINTAIN PROPER GUARDS AND ANY OTHER NECESSARY CONSTRUCTION REQUIRED TO SECURE SAFETY OF LIFE AND PROPERTY. 1.17. ACCESSIBILITY: ALL WORK PROVIDED UNDER THIS SECTION SHALL BE PROVIDED SO THAT PARTS REQUIRING PERIODIC INSPECTION, MAINTENANCE AND REPAIR ARE READILY ACCESSIBLE, WORK OF THIS TRADE SHALL NOT INFRINGE UPON THE CLEARANCES OF OTHER TRADES. 1.18. PROTECTION OF WORK AND PROPERTY: THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE CARE AND THE PROTECTION OF ALL WORK INCLUDED UNDER THIS SECTION UNTILTHE COMPLETION AND FINAL ACCEPTANCE OF THIS PROJECT. PROTECT ALL EQUIPMENT AND MATERIALS FROM DAMAGE FROM ALL CAUSES INCLUDING, BUT NOT LIMITED TO, FIRE, VANDALISM, AND THEFT. ALL MATERIALS AND EQUIPMENT DAMAGED OR STOLEN SHALL BE REPAIRED OR REPLACED WITH EQUAL MATERIAL OR EQUIPMENT AT NO ADDITIONAL COSTTO THE OWNER. PROTECT ALL EQUIPMENT, OUTLETS AND OPENINGS, AND ROOF PENETRATIONS WITH TEMPORARY PLUGS, CAPS AND COVERS. PROTECT WORK AND MATERIALS OF OTHER TRADES FROM DAMAGE THAT MIGHT BE CAUSED BY WORK OR WORKMEN UNDER THIS SECTION AND MAKE GOOD ON DAMAGE THUS CAUSED. DAMAGED MATERIALS SHALL BE REMOVED FROM THE SITE; DAMAGE CAUSED BY THE ELECTRICAL CONTRACTOR DURING INSTALLATION SHALL BE REPAIRED AND/OR REPLACED AT THIS CONTRACTOR'S EXPENSE TO THE COMPLETE SATISFACTION OF THE BUILDING OWNER. 1.19. SEISMIC RESTRAINT REQUIREMENTS: PROVIDE SEISMIC RESTRAINTS AS REQUIRED IN ACCORDANCE WITH THE STATE BUILDING CODE. A REGISTERED PROFESSIONAL STRUCTURAL ENGINEER, LICENSED IN THE APPLICABLE STATE FOR THE PROJECT LOCATION, SHALL PREPARE THE SEISMIC RESTRAINT DESIGN AND CERTIFY THAT THE DESIGN IS IN COMPLIANCE WITH THE STATE BUILDING CODE REQUIREMENTS. 1.20. PROJECT CLOSEOUT: A CERTIFICATE OF COMPLETION SHALL BE ISSUED BY THE ELECTRICAL CONTRACTOR INDICATING THAT THE INSTALLATION IS IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS AND ALL APPLICABLE LOCAL, STATE AND FEDERAL STATUTES AND CODES. FINAL INSPECTION BY THE ENGINEER SHALL BE CONDUCTED AFTER RECEIPT OF THE CERTIFICATE OF COMPLETION. NO LIFE SAFETY DEFICIENCIES IN THE EGRESS OR EXIT LIGHTING SYSTEMS, FIRE ALARM SYSTEM, OR THE EMERGENCY POWER SYSTEM SHALL BE PRESENT WHEN REQUESTING FINAL INSPECTION. PREMATURE REQUESTS FOR FINAL INSPECTIONSTHAT REQUIRE REINSPECTION OF DEFICIENT ITEMS WILL RESULT IN BACK CHARGES OF THE COSTS ASSOCIATED WITH THE REINSPECTION. 1.21. TEMPORARY POWER AND LIGHTING: 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND PAY FOR CAPACITY FROM THE LOCAL UTILITY COMPANY POWER LINES, MAKE ARRANGEMENTS WITH THE LOCATION UTILITY COMPANY FOR TEMPORARY SERVICE AS REQUIRED. 2. PROVIDE ADEQUATE DISTRIBUTION EQUIPMENT, WIRING, AND OUTLETS FOR POWER AND LIGHTING. 3. PROVIDE POWER OUTLETS FOR CONSTRUCTION OPERATIONS, WITH BRANCH WIRING AND DISTRIBUTION BOXES LOCATED AS REQUIRED. 4. PROVIDE 20 AMPERE DUPLEX OUTLETS, SINGLE PHASE CIRCUITS FOR POWER TOOLS IN THE ACTIVE WORK AREA AS REQUIRED. PERMANENT CONVENIENCE RECEPTACLES MAY BE UTILIZED DURING THE PROCESS. CONSTRUCTION THE GENERAL CONTRACTOR SHALL PRO L PAY ALL UTILITY COMPANY USAGE BILLINGS. 5. PROVIDE GFCI PROTECTED POWER OUTLETS FOR CONSTRUCTION OPERATIONS, WITH BRANCH WIRING AND DISTRIBUTION BOXES LOCATED AS REQUIRED. 6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FOR TEMPORARY LIGHTING, PROVIDING AND MAINTAINING OSHA REQUIRED LIGHTING LEVELS FOR CONSTRUCTION OPERATIONS. 7. PROVIDE BRANCH WIRING FROM POWER SOURCE TO DISTRIBUTION BOXES WITH LIGHTING CONDUCTORS, PIGTAILS, AND LAMPS AS REQUIRED. 8. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN LIGHTING AND PROVIDE ROUTINE REPAIRS AS REQUIRED. PERMANENT BUILDING LIGHTING MAY BE UTILIZED DURING CONSTRUCTION. POWER SHALL BE DERIVED FROM THE EXISTING BUILDING AND KWH USAGE PAID BY THE OWNER. 1.22. DRAWINGS AND SPECIFICATIONS: THE DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY EACH TO THE OTHER, AND ANY LABOR OR MATERIAL CALLED FOR BY EITHER, WHETHER OR NOT BY BOTH, OR NECESSARY FOR THE SUCCESSFUL OPERATION OF ANY COMPONENTS SHALL BE PROVIDED. BEFORE INSTALLING ANY WORK, VERIFY THAT IT DOES NOT INTERFERE WITH THE CLEARANCES REQUIRED FOR OTHER WORK. INSTALLED WORK WHICH INTERFERES WITH EXISTING NECESSARY SERVICES SHALL BE MODIFIED AS DIRECTED BY THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER. BE FAMILIAR WITH THE DRAWINGS AND SPECIFICATIONS OF ALL OTHER TRADES TO PREVENT INTERFERENCES AND ASSURE COMPLETE COORDINATION. IF THERE ARE ANY DISCREPANCIES BETWEEN THE ELECTRICAL DRAWINGS AND SPECIFICATIONS REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER PRIOR TO START AND OR CONTINUATION OF ANY WORK OR THE PROCUREMENT OF ANY MATERIALS AND EQUIPMENT. PART 2 - PRODUCTS 2.1. FIRE ALARM SYSTEM: 1. GENERAL: PROVIDE AN ADDITION AND MODIFICATION TO THE EXISTING AUTOMATIC AND MANUAL, AUXILIARY CONNECTED FIRE ALARM SYSTEM, ACCORDING TO THE FOLLOWING SPECIFICATIONS TO BE WIRED, CONNECTED, TESTED AND LEFT IN FIRST CLASS OPERATING CONDITION. ALL EQUIPMENT SHALL BE UNDERWRITERS' LABORATORIES APPROVED FOR THE INTENDED USE AND SHALL MEET WITH THE APPROVAL OF THE LOCAL AUTHORITY. THE COMPLETE SYSTEM SHALL BE AS MANUFACTURED BY SIEMENS. THE COMPLETE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE SECTIONS OF NFPA STANDARDS, SECTION 72, 101 LIFE SAFETY, THE STATE OF MASSACHUSETTS BUILDING CODES, THE STATE OF MASSACHUSETTS SAFETY CODES AND ALL LOCAL CODES AND REQUIREMENTS, ALL MODIFICATIONS TO CONTROL EQUIPMENT MUST BE WITH THE SAME BRAND OF EQUIPMENT AS THE EXISTING. 2. ALL DEVICES MUST BE U.L. LISTED AS COMPATIBLE WITH THE CONTROL EQUIPMENT. SUBMIT PROOF OF COMPATIBILITY WITH SHOP DRAWING SUBMITTAL. 3. REPLACE ANY EXISTING EQUIPMENT AND WIRING THAT IS NOT COMPATIBLE WITH THE EQUIPMENT THAT YOU PROVIDE OR THE MODIFICATIONS THAT YOU MAKE, WITHOUT ADDITIONAL COMPENSATION. 4. DEVICES PROVIDE ADDITIONAL FIRE ALARM ES AS SHOWN ON THE DRAWINGS. NEW C DEVICES SHALL MATCH AND BE FULLY COMPATIBLE WITH EXISTING EQUIPMENT; PROVIDE IN WHITE FINISH UNLESS OTHERWISE NOTED_ THE MANUFACTURE OF THE NEW EQUIPMENT SHALL MATCH EXISTING. EXTENSION OF EXISTING FIRE ALARM SYSTEM SHALL INCLUDE INFRASTRUCTURE UPGRADES INCLUDING EXISTING FIRE ALARM CONTROL PANEL, ADDITIONAL POWER SUPPLIES, AMPLIFIERS, BATTERIES, SOFTWARE AND ALL OTHER ADDITIONAL COMPONENTS AS REQUIRED TO PROVIDE AND FULLY FUNCTIONAL FIRE ALARM SYSTEM. PRIOR TO SUBMITTING SHOP DRAWINGS THE ELECTRICAL CONTRACTOR AND/OR THEIR FIRE ALARM VENDOR SHALL FIELD VERIFY THATTHE EXISTING FIRE ALARM CONTROL PANEL IS EXPANDABLE AND IS NOT LIMITED TO SOFTWARE COMPATIBILITY, HARDWARE, AVAILABILITY OF PARTS, ETC. IF IT IS FOUND THAT THE EXISTING FIRE ALARM CONTROL PANEL CANNOT BE USED IN THE NEW DESIGN PER THE CONSTRUCTION DOCUMENTS, THEN THE ELECTRICAL CONTRACTOR SHALL PROVIDE SEPARATE PRICING FOR REPLACING THE CONTROL PANEL WITH A FULLY COMPATIBLE TYPE AND RE -PROGRAMING OF ALL EXISTING DEVICES AS REQUIRED. 5. AS IT IS NOT PRACTICAL TO ENUMERATE IN THESE SPECIFICATIONS ALL DETAILS OF FITTINGS AND ACCESSORY EQUIPMENT REQUIRED FOR PROPER OPERATION OF THE SYSTEM HEREIN DESCRIBED, IT IS UNDERSTOOD THAT THEY WILL BE SUPPLIED BY THE CONTRACTOR WITHOUT EXTRA COMPENSATION. PROVIDE ALL FITTINGS, TERMINATIONS, ETC., NEEDED FOR THE BEST PERFORMANCE POSSIBLE AT THE PRESENT STATE-OF-THE-ART. 6. WIRING: THE ELECTRICAL SUBCONTRACTOR SHALL PROVIDE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, ALL WIRING, CONDUIT AND OUTLET BOXES REQUIRED FOR INSTALLATION OF A COMPLETE SYSTEM AS DESCRIBED HEREIN AND AS SHOWN ON THE PLANS. PROVIDE ALL WIRING IN METALLIC RACEWAY. PROVIDE NO. 14 GAUGE, THWN, SOLID CONDUCTORS AND COLOR CODE AS REQUIRED. 7. TAG ALL WIRES AT ALL JUNCTION POINTS AND TEST FREE FROM GROUNDS OR CROSSES BETWEEN CONDUCTORS. CARRY THE WIRING SYSTEM THROUGH ALL EQUIPMENT. PROVIDE RED PAINTED TERMINAL CABINETS WITH HINGED LOCKABLE COVERS AT ALL JUNCTION POINTS. MAKE ALL CONDUCTOR SPLICES ON SCREW TYPE TERMINAL BLOCKS; WIRE NUTS SHALL NOT BE USED. PROPERLY LABEL ALL TERMINALS WITHIN TERMINAL CABINETS. MAKE FINAL CONNECTIONS BETWEEN CONTROL EQUIPMENT AND THE WIRING SYSTEM UNDER DIRECT SUPERVISION OF A REPRESENTATIVE OF THE MANUFACTURER. 8. SUBMIT COMPLETE DOCUMENTATION FOR THE FIRE ALARM/LIFE SAFETY SYSTEM SHOWING THE MODEL NUMBER, TYPE, RATING, SIZE, STYLE, MANUFACTURER'S NAMES, AND MANUFACTURER'S CATALOG DATA SHEETS FOR ALL ITEMS TO ENSURE COMPLIANCE WITH THESE SPECIFICATIONS. 9. UPON CONTRACT BID APPROVAL, AND PRIOR TO START OF SYSTEM INSTALLATION, SUBMIT SHOP DRAWINGS TO AND OBTAIN WRITTEN APPROVAL FROM THE FIRE DEPARTMENT, PRIOR TO ORDERING FIRE ALARM EQUIPMENT, GENERAL REQUIREMENTS ARE AS FOLLOWS: A. SYSTEM OPERATION DESCRIPTION: DETAILED DESCRIPTION FOR THIS PROJECT, INCLUDING METHOD OF OPERATION AND SUPERVISION OF EACH TYPE OF CIRCUIT AND SEQUENCE OF OPERATIONS FOR MANUALLY AND AUTOMATICALLY INITIATED SYSTEM INPUTS AND OUTPUTS. MANUFACTURER'S STANDARD DESCRIPTIONS FOR GENERIC SYSTEMS ARE NOT ACCEPTABLE. B. DEVICE ADDRESS LIST: COORDINATE WITH FINAL SYSTEM PROGRAMMING. C. SYSTEM RISER DIAGRAM WITH DEVICE ADDRESSES, CONDUIT SIZES, AND CABLE AND WIRE TYPES AND SIZES. D. WIRING DIAGRAMS: POWER, SIGNAL, AND CONTROL WIRING. INCLUDE DIAGRAMS FOR EQUIPMENT AND FOR SYSTEM WITH ALL TERMINALSAND INTERCONNECTIONS IDENTIFIED. SHOW WIRING COLOR CODE. E. BATTERIES: SIZE CALCULATIONS. 10. SUBMIT SHOP DRAWINGS TO AND OBTAIN WRITTEN APPROVAL FROM THE AUTHORITIES HAVING JURISDICTION, PRIOR TO ROUGHING. RESUBMIT IF REQUIRED TO MAKE CLARIFICATIONS OR REVISIONS TO OBTAIN APPROVAL. ON RECEIPT OF COMMENTS FROM AUTHORITIES HAVING JURISDICTION, SUBMIT THEM TO ENGINEER FOR REVIEW. 11. GUARANTEE AND FINAL TEST: GUARANTEE ALL NEW EQUIPMENT AND WIRING TO BE FREE FROM INHERENT MECHANICAL AND ELECTRICAL DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE SERVICES OF THE BUILDING FIRE ALARM MAINTENANCE CONTRACTOR FOR TIE-IN OF NEW FIRE ALARM CIRCUITRY. 12. BEFORE THIS INSTALLATION SHALL BE CONSIDERED COMPLETE AND ACCEPTABLE TO THE AWARDING AUTHORITIES, A COMPLETE TEST ON THE SYSTEM SHALL BE PERFORMED AS FOLLOWS: THE ELECTRICAL CONTRACTOR'S JOB FOREMAN, IN THE PRESENCE OF A REPRESENTATIVE OF THE FIRE ALARM MAINTENANCE CONTRACTOR, FIRE ALARM MANUFACTURER AND A REPRESENTATIVE OF THE LOCAL FIRE DEPARTMENT, SHALL OPERATE EACH ALARM INITIATING DEVICE AND VERIFY ZONE ANNUNCIATION, AUDIBLE AND VISUAL SIGNALING AND PROPER OPERATION OF THE MASTER BOX. EACH CIRCUIT SHALL BE OPENED AT ITS MOST REMOTE POINTTO CHECK FORTH E CORRECTNESS OF THE SUPERVISORY CIRCUITRY. WHEN THE ABOVE TEST HAS BEEN COMPLETED TO THE SATISFACTION OF THE MANUFACTURER'S REPRESENTATIVE, THE ELECTRICAL SUBCONTRACTOR'S JOB FOREMAN, AND THE LOCAL FIRE DEPARTMENT, A LETTER WITNESSED AND CO -SIGNED BY ALL ATTESTING TO THE COMPLETION OF THIS TESTING SHALL BE FORWARDED TO THE ENGINEER. TEST TO INCLUDE BOTH NEW AND EXISTING WIRING AND EQUIPMENT. 13. DURING THE GUARANTEE PERIOD, 24 HOUR SERVICE (365 DAYS/YEAR) IS REQUIRED OF THE CONTRACTOR AND EQUIPMENT SUPPLIER. 14. QUARTERLY TESTING, AS REQUIRED BY THE MASSACHUSETTS FIRE SAFETY CODE IS NOT PART OF THIS CONTRACT. 15. SERVICE CALLS RESULTING FROM ACTS OF VANDALISM, ACTS OF NATURE, OR ACTS WHICH ARE BEYOND THE CONTROL OF THE EQUIPMENT MANUFACTURER ARE EXCLUDED UNDER THE GUARANTEE AND SHALL BE CONSIDERED A BILLABLE CALL. 2.2. WIRE AND CABLE: WIRING SHALL BE TYPE THHN/THWN OR XHHW, MINIMUM OF #12 AWG SOLID COPPER WITH CONDUCTIVITY OF NOT LESS THAN 98% OF THE ANSI STANDARD FOR ANNEALED COPPER, UL LISTED FOR BUILDING WIRE 90 DEGREES CELSIUS. WET OR DRY LOCATIONS RATED FOR 600V SERVICE. MC AND FAMC CABLING CAN BE USED WHERE CONCEALED. CONDUCTORS LARGER THAN #10 SHALL BE STRANDED. COLOR CODING SHALL BE CONSISTENT THROUGHOUT. 2.3. CONDUIT: ELECTRIC METALLIC TUBING SHALL BE ELECTRO-GALVANIZED SHERARDIZED STEEL. WHERE EXPOSED, ALL WIRING SHALL BE INSTALLED IN CONDUIT. ALL ROUTING OF CONDUIT SHALL BE RUN PERPENDICULAR TO BUILDING WALLS. ALL ELECTRIC METALLIC TUBING SHALL BE UTILIZED WITH STEEL SET SCREW TYPE FITTINGS. CONDUIT SHALL BE TUBING SHALL BE UTILIZED WITH STEEL SET SCREW TYPE FITTINGS, CONDUIT SHALL BE SUPPORTED FROM BUILDING STRUCTURE; AND SHALL BE INDEPENDENT OF DUCTS, PIPES, CEILING AND THEIR SUPPORTING MEMBERS. CONTRACTOR SHALL PATCH AND REPAIR EXISTING FIRESTOPPING TO RESTORE ORIGINAL FIRE -RESISTANCE RATING OF BUILDING STRUCTURE FOLLOWING INSTALLATION. ALL FIRESTOPPING SHOULD BE BY G.C.. 2.4. WIRING DEVICES: 1. LIGHTSWITCHES: A. REFER TO DRAWINGS. B. COLOR OF SWITCHES SHALL BE AS SELECTED BY ARCHITECT. 2. OCCUPANCY SENSORS: A. REFER TO DRAWINGS. 3. RECEPTACLES: A. DUPLEX RECEPTACLES SHALL BE SPECIFICATION GRADE GROUNDING TYPE, RATED 20 AMPERES, 125 VOLTS. RECEPTACLES SHALL BE BACK AND SIDE WIRED WITH SCREW TYPE TERMINALS HAVING SUITABLE CONDUCTOR RELEASE ARRANGEMENT GFCI RECEPTACLES SHALL BE SPECIFICATION GRADE 20 AMPERES, 125 VOLTS. B, COLOR OF RECEPTACLES SHALL BE AS SELECTED BY ARCHITECT. 2.S. LIGHTING FIXTURES: A. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR A COMPLETE INSTALLATION OF THE LIGHTING EQUIPMENT SPECIFIED ON THE LIGHTING FIXTURE SCHEDULE. B. INTERIOR LIGHTING FIXTURES SHALL BE 3500°K UNLESS NOTED OTHERWISE. C. LIGHTING FIXTURES SHALL BE SUPPORTED ABOVE CEILING FROM STRUCTURAL FLOOR ABOVE VIA #12 JACK CHAIN AND "Y" HANGERS FROM TWO OPPOSITE CORNERS. D. EXIT SIGNS SHALL BE TYPICALLY MOUNTED ON CEILING WHERE VISIBLE OR ON WALL WHERE CEILING MOUNTING IS NOT PRACTICAL. PRIOR TO ROUGHING COORDINATE WITH ARCHITECTURAL DRAWINGS/ELEVATIONS FOR SPECIFIC MOUNTING DIRECTION AND FOR LOCATION. E. WHERE LIGHTING FIXTURES OTHER THAN THE SPECIFIED PRODUCTS ARE PROVIDED, THE CONTRACTOR SHALL PROVIDE LIGHT LEVEL CALCULATIONS IN ACCORDANCE WITH IESNA STANDARDS TO JUSTIFY THAT SUBSTITUTED FIXTURES ARE OR EQUAL PERFORMANCE TO THE SPECIFIED PRODUCTS (APPLIES TO ALL LIGHTING FIXTURES IN ALL SPACES). F. WHERE SUBMITTING TO ENGINEER FOR REVIEW THE LIGHTING FIXTURE SUBMITTALS SHALL CONSIST OF THE FOLLOWING: LIGHTING FIXTURE CUT SHEET, LIGHTING FIXTURE BALLAST/DRIVER CUT SHEET, AND LIGHTING FIXTURE LAMP/LED CUT SHEET FOR EACH FIXTURE. GROUPED CUT SHEETS WILL NOT BE ALLOWED. WHEN SUBMITTING ON LED PRODUCTS PROVIDE LIGHTING FACTS, LM-79 AND LM-80 TEST REPORTS FOR REVIEW. 2.6. OUTLET BOXES: PROVIDE OUTLET BOXES AS REQUIRED FOR ALL ELECTRICAL DEVICES AND EQUIPMENT. MINIMUM SIZE OF BOXES SHALL BE 4", 1-1/4" DEEP. ALL OUTLET BOXES SHALL BE GALVANIZED STEEL. 2.7. PULL BOXES, JUNCTION BOXES AND WIREWAYS: A. PULL BOXES SHALL BE OF CODE GAUGE GALVANIZED STEEL WITH SCREW COVERS TO MATCH. PULL BOXES AND WIREWAYS SHALL BE AS SHOWN ON CONTRACT DRAWINGS AND/OR AS REQUIRED BY THE NATIONAL ELECTRICAL CODE AND/OR JOB CONDITIONS, WITH STEEL BARRIERS SEPARATING SYSTEMS. B. WIREWAYS SHALL BE OF CODE GAUGE STEEL, BAKED ENAMEL MANUFACTURED STANDARD SECTIONS AND STEEL FITTINGS, WITH COMBINATION HINGED AND SCREW COVERS. C. CONDUCTORS PASSING THROUGH PULL BOXES AND WIREWAYS SHALL BE IDENTIFIED TO INDICATE THEIR ORIGIN AND TERMINATION. PROVIDE NAMEPLATES FOR ALL PULL BOXES. 2.8. THERMAL SWITCHES: A. THERMAL SWITCHES SHALL BE NEMA TYPE 1 TOGGLE SWITCH FOR NORMAL DUTY WITH THERMAL OVERLOAD RELAY. B. SWITCH ENCLOSURES SHALL BE OF A TYPE APPROVED FOR THE LOCATION AND ATMOSPHERE IN WHICH IT IS MOUNTED. C. THERMAL SWITCHES SHALL BE INSTALLED WHERE CALLED FOR OR WHERE REQUIRED BY CODE. D. THERMALSWITCHES SHALL BE PROVIDED WITH PILOT WHERE CALLED FOR ON THE DRAWINGS. 2.9. CIRCUIT BREAKERS FOR EXISTING PANELBOARDS: A. CIRCUIT BREAKERS SHALL BE EQUAL TO THE EXISTING CIRCUIT BREAKERS AND OF THE SAME MANUFACTURER AS THE EXISTING PANELBOARDS IN WHICH THEY ARE TO BE INSTALLED. B. PROVIDE UPDATED TYPEWRITTEN CIRCUIT DIRECTORY CARDS INDICATING AREAS AND DEVICES SERVED BY EACH CIRCUIT IN ALL EXISTING PANELBOARDS PANELS AFFECTED BY THE WORK OF THIS PROJECT. 2.10. PANELBOARDS: A. AT EACH LOCATION INDICATED ON THE PLANS, FURNISH AND INSTALL AN APPROPRIATE PANEL OF THE AMPACITY AND VOLTAGE RATING SHOWN ON THE DRAWINGS. B. ALL PANELS SHALL BE OF THE SAFETY DEAD FRONT CIRCUIT BREAKER TYPE FOR SERVICE ON THREE PHASES, FOUR WIRE MAINS UNLESS OTHERWISE SPECIFIED. C. ALL PANELS SHALL BE OF CODE GAUGE STEEL. D. PANELS SHALL BE SURFACE OR FLUSH MOUNTED, AS INDICATED ON THE PLANS, AND INSTALLED SO THAT THE TOP CIRCUIT BREAKER IS NO MORE THAN 6-0"ABOVE THE FINISHED FLOOR. E. THE PANELBOARDS SHALL BEAR THE UNDERWRITERS' LABORATORIES LABEL. F. ALL BUSES SHALL BE COPPER. G. ALL PANELBOARDS SHALL HAVE A CIRCUIT DIRECTORY CARD MOUNTED IN A FRAME WITH PLASTIC COVER INSTALLED ON THE INSIDE OF THE DOOR. H. ALL DIRECTORY CARDS SHALL BE PROPERLY FILLED IN, USING A TYPEWRITER, AND INDICATING AREAS AND DEVICES SERVED BY EACH CIRCUIT. I. ALL CIRCUIT BREAKERS SHALL BE OF QUICK -MAKE AND QUICK -BREAK TYPE ON MANUAL OPERATION, TRIP -FREE, AND WITH INVERSE TIME CHARACTERISTICS AND SHALL HAVE BOLTED BUS CONNECTIONS; PLUG-IN CIRCUIT BREAKERS WILL NOT BE ALLOWED. J. PANELBOARD TRIMS SHALL BE DOOR -IN -DOOR DESIGN. K. TRIMS AND DOORS SHALL BE MADE OF CODE GAUGE, FULL FINISH SHEET STEEL. L. THE TRIM AND DOORS SHALL BE FACTORY FINISHED ON BOTH SIDES. M. ALL PANELBOARDS SHALL BE KEYED ALIKE. N. PANELBOARDS SHALL CONTAIN CIRCUIT BREAKERS INDICATED ON PANELBOARD SCHEDULE ON THE DRAWINGS. 0. TWO AND THREE POLE BREAKERS SHALL BE COMMON TRIP TYPE. P. ALL PANELBOARDS SHALL BE EQUIPPED WITH A NEUTRAL BAR HAVING ONE SOLDERLESS CONNECTOR FOR EACH CIRCUIT AS INDICATED AND WITH ALL REQUIRED KNOCKOUTS. Q. NEW PANELBOARDS SHALL BE MANUFACTURED BY GENERAL ELECTRIC. 2.11. DRY TYPE TRANSFORMER: A. DRY TYPE TRANSFORMER SHALL MEET NEMA PREMIUM EFFICIENCY LEVELS, U.L. LISTED. B. NOISE LEVEL SHALL BE A MAXIMUM OF 50 DB AVERAGE MEASURED AT DISTANCE OF 1" FROM CASE PER NEMA PUBLICATION #TR-1-1960 PER LARGE REVISION THEREOF. C. PROVIDE SUPPLEMENTAL STEEL AS REQUIRED TO DISTRIBUTE LOADING. D. SEE TRANSFORMER SCHEDULE FOR ADDITIONAL INFORMATION. E. MANUFACTURER SHALL BE GENERAL ELECTRIC. 2.12. DISCONNECT SWITCHES: A. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL DISCONNECTING MEANS AS REQUIRED BY THE NATIONAL ELECTRICAL CODE FOR ALL MOTORS, B. MANUAL MOTOR STARTERS SHALL HAVE QUICK MAKE, QUICK BREAK TOGGLE MECHANISMS WITH ALLOWANCE FOR UP TO 10% FIELD ADJUSTMENTTO NOMINAL OVERLOAD HEATER VALUES. C. DISCONNECT SWITCHES SHALL BE FUSED OR UNFUSED AS SHOWN ON THE DRAWINGS, OR AS REQUIRED, NEMA TYPE HD SAFETY SWITCHES FOR HEAVY DUTY, WITH INTERLOCKING COVER, SIDE OPERATED WITH PROVISIONS FOR PADLOCKING THE SWITCH HANDLE IN THE OFF POSITION. D. ALL MOTOR ISOLATING SWITCHES INDICATED ON THE DRAWINGS SHALL BE RATED IN HORSEPOWER, AND SHALL BE RATED FOR THE VOLTAGE OF THE MOTOR AND SHALL BE FURNISHED AND INSTALLED AT THE MOTOR LOCATION WHETHER OR NOT THE MOTOR IS WITHIN SIGHT OF THE MOTOR FEEDER DISCONNECTING MEANS. E. DISCONNECT SWITCH ENCLOSURES SHALL BE OF THE PROPER NEMA TYPE FOR THE INTENDED LOCATION AS DEFINED BY NEMA AND SHALL BE PHOSPHATE COATED OR EQUIVALENT CODE GAUGE GALVANIZED SHEET STEEL WITH USAF[ NO. 24 DARK GRAY BAKED ENAMEL FINISH. F. FUSES E HALL BE CLASS RK-1 SIZE PER DRAWING AND NAMEPLATE S D REQUIREMENTS. G. INSTALL REJECTION CLIPS TO PROHIBIT INSTALLATION OF OTHER THAN CURRENT LIMITING FUSES. H. DISCONNECT SWITCHES SHALL BEAR THE UNDERWRITERS' LABORATORIES LABEL AND BE MANUFACTURED BY SQUARE D COMPANY. PART 3 - EXECUTION 3.1. GENERAL: A. ALL INTERRUPTIONS AND SHUTDOWNS OF EXISTING ELECTRICAL SYSTEMS AND SERVICES SHALL BE AS SHORT AS POSSIBLE AND AT TIME AND DURATION APPROVED BY THE OWNER AND THE ENGINEER. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL PREMIUM TIME ASSOCIATED WITH THE SYSTEM AND SERVICE INTERRUPTIONS AND SHUTDOWNS. 3.2. CLEANING, ADJUSTING, AND TESTING: A. AT THE COMPLETION OF THE WORK, ALL PARTS OF THE INSTALLATION SHALL BE THOROUGHLY CLEANED. ALL DEVICES, EQUIPMENT, CONDUITS, AND FITTINGS SHALL BE COMPLETELY CLEANED OF GREASE, METAL CUTTINGS, DIRT WHICH MAY HAVE ACCUMULATED DURING CONSTRUCTION, AND PROTECTION COVERS. B. ANY DISCOLORATION OR DAMAGE TO PARTS OF THE BUILDING, ITS FINISH OR FURNISHINGS DUE TO FAILING TO PROPERLY CLEAN THE ELECTRICAL SYSTEM SHALL BE REPAIRED BY THE ELECTRICAL CONTRACTOR WITHOUT COST TO THE OWNER. C. THE ELECTRICAL CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIRECTED BY THE ARCHITECT AND AS REQUIRED BY AUTHORITIES HAVING JURISDICTION, FURNISH ALL EQUIPMENT, NECESSARY PERSONNEL AND THE ELECTRICAL POWER. D. THE ENTIRE INSTALLATION SHALL BE TESTED FOR SHORTS, GROUNDS AND OPEN CIRCUITS AND ALL DEFECTS SHALL BE CORRECTED BEFORE ACCEPTANCE OF WORK. E. ALL WORK SHALL BE DEMONSTRATED TO BE IN PROPER OPERATING CONDITION TO THE COMPLETE SATISFACTION OF THE ARCHITECT, TENANT, AND BUILDING OWNER. 3.3. EQUIPMENT CONNECTIONS: THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONNECTIONS TO ALL EQUIPMENT REQUIRING ELECTRICAL SERVICE, INCLUDING POWER CABLES, BRANCH CIRCUIT EXTENSIONS, FIRE ALARM CABLES, MOTORS, CONTROLLERS, LIGHTING FIXTURES AND ALL OTHER EQUIPMENT AND SYSTEMS SPECIFIED OR SHOWN ON THE DRAWINGS. 3.4. GROUNDING AND BONDING: PROVIDE GROUNDING AND BONDING METHODS IN ACCORDANCE WITH NEC CODE ARTICLE 250 AND LOCAL UTILITY COMPANY REGULATIONS, 3.5. CONDUIT WORK: 1. BRANCH CIRCUIT WIRING IN HUNG CEILINGS, FURRED SPACES OR EXPOSED AND NOT SUBJECT TO PHYSICAL DAMAGE MAY BE INSTALLED IN ELECTRICAL METALLIC TUBING. 2. TYPE MC CABLE MAY BE USED WHERE REQUIRED FOR "FISHING" INTO EXISTING WALL AND CEILING CAVITIES. 3. CONDUIT EXTENSIONS IN METAL PARTITIONS MAY BE MADE WITH FLEXIBLE METAL CONDUIT, WITH GROUNDING CONDUCTOR. 4. CONNECTIONS TO PORTABLE AND PERMANENTLY MOUNTED MOTORIZED EQUIPMENT AND MOTORS, AS WELL AS THE EQUIPMENT HOUSING, SHALL BE MADE WITH APPROVED LIQUID TIGHT FLEXIBLE METAL CONDUIT. 5. FLEXIBLE CONNECTIONS SHALL BE A MAXIMUM OF 18" LONG AND WITH GROUNDING CONDUCTOR. 6. FLEXIBLE CONNECTIONS SHALL BE USED PRIOR TO ATTACHMENT TO EQUIPMENT HOUSINGS. 7. CONDUIT ENDS SHALL BE CUT SQUARE, THREADED AND REAMED TO REMOVE BURRS AND SHARP EDGES. 8. FIELD THREADS SHALL BE OF THE SAME TYPE AND HAVE THE SAME EFFECTIVE LENGTH AS FACTORY CUT THREADS. 9. EXCESSIVE EXPOSED THREADS WILL NOT BE ALLOWED. 10. TURNS, WHEREVER REQUIRED IN EXPOSED CONDUIT RUNS SHALL BE MADE BY THE USE OF FACTORY -MADE BENDS, OR FIELD MADE BENDS. 11. CONDULETS, OR IN THE EVENT OF A MULTIPLICITY OF CONDUITS MAKING THE SAME TURN, A STEEL JUNCTION BOX WITH A REMOVABLE STEEL COVER MAY BE USED. 12. OFFSETS AND BENDS FOR CHANGES IN ELEVATION OF EXPOSED CONDUIT RUNS SHALL BE MADE AT WALLS OR BEAMS AND NOT IN OPEN SPACES BETWEEN WALLS OR BEAMS. 13. CONDUITS SHALL BE ROUTED SO AS NOT TO INTERFERE WITH THE OPERATION OF MAINTENANCE OF ANY EQUIPMENT. 14. THE ENTIRE JOB SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 15. ALL CONDUIT WORK SHALL BE CAREFULLY CLEANED AND DRIED INSIDE BEFORE THE INSTALLATION OF CONDUCTORS. 16. PLUG CONDUIT ENDS TO EXCLUDE DUST, MOISTURE, PLASTER OR SIMILAR WHILE TENANT FIT -OUT IS UNDER CONSTRUCTION. 17. NO LUBRICANTS OR CLEANING AGENTS WHICH MIGHT HAVE A DELETERIOUS EFFECTS ON CONDUCTOR COVERINGS SHALL BE USED FOR DRAWING CONDUCTORS INTO RACEWAYS. 1 DRAWINGS, IN RE T TO ROUTING OF CONDUITS ARE DIAGRAMMATIC. 8. RELATION I M 19. THE NUMBER AND SIZE OF CONDUITS AND WIRE SHALL BE FURNISHED AND INSTALLED AS INDICATED BY THE DRAWINGS. 20. CONDUITS SHALL BE ROUTED IN THE FIELD SO AS TO BE COORDINATED WITH THE BUILDING STRUCTURE AND ALL OTHER TRADES. 21. CONCEALED CONDUIT SHALL BE AS SHORT AND DIRECT AS POSSIBLE. 22. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL TO WALLS, BEAMS AND COLUMNS AND WITH RIGHT ANGLE BENDS AND STEEL THREADED CONDUIT FITTINGS. 23. CONDUITS PASSING THROUGH FLOORS, WALLS AND BEAMS SHALL BE OF SUCH SIZE, NUMBER AND IN SUCH LOCATIONS SO AS NOT TO IMPAIR THE STRENGTH OF THE EXISTING CONSTRUCTION. 24. PARTICULAR ATTENTION SHALL BE GIVEN TO THE INSTALLATION OF CONDUITS AT GROUPED AREAS, SUCH AS PANELBOARD, CABINET AND PULL BOX ENTRANCES. 25. RACEWAYS IN CEILING SPACES SHALL BE ROUTED IN SUCH AN APPROVED MANNER AS TO ELIMINATE OR MINIMIZE THE NUMBER OF JUNCTION BOXES REQUIRED, BUT ALSO SHALL BE ROUTED IN AN ORDERLY AND ORGANIZED MANNER. 26. SUPPORT RODS AND CLAMPS SHALL BE FURNISHED AND INSTALLED AS REQUIRED FOR COMPLETE INSTALLATION. 27. SUPPORT OF CONDUITS BY USE OF WIRE IS STRICTLY PROHIBITED. 28. CONDUITS SHALL BE SUPPORTED AND SECURED BY CONDUIT SUPPORT DEVICES. 29. WHERE RIGID METAL CONDUIT IS THREADED IN THE FIELD, A STANDARD CONDUIT CUTTING DIE PROVIDING 3/4" TAPER PER FOOT SHALL BE EMPLOYED. 30. THREADLESS COUPLING SHALL NOT BE USED ON RIGID METAL CONDUIT EXCEPT WHERE SPECIFICALLY ALLOWED BY THE ARCHITECT. 31. RUNNING THREADS SHALL NOT BE USED ON RIGID METAL CONDUIT. 32. CONDUIT WORK SHALL BE INSTALLED IN SUCH A MANNER TO KEEP EXPOSED THREADS TO AN ABSOLUTE MINIMUM, AND IN NO CASE SHALL MORE THAN THREE THREADS BE LEFT EXPOSED AFTER THE CONDUIT WORK IS MADE UP TIGHT. 33. THIS REQUIREMENT APPLIES TO ALL CONDUIT WORK. 34. MINIMUM SIZE CONDUIT SHALL BE 1/2" NOMINAL TRADE SIZE. 35. A MINIMUM 3/16" DIAMETER TWISTED NYLON PLASTIC TYPE FISH CORD SHALL BE FURNISHED AND INSTALLED IN ALL EMPTY RACEWAYS. 36. PROVIDE A TAG ON EACH END OF FISH CORD INDICATING THE LOCATION OF THE OTHER END. ii 3.6. FIRE STOPPING: 1. ELECTRICAL INSTALLATIONS IN HOLLOW SPACES, VERTICAL SHAFTS AND VENTILATION OR AIR HANDLING DUCTS SHALL BE SO MADE THAT THE POSSIBLE SPREAD OF FIRE OR PRODUCTS OF COMBUSTION WILL NOT BE SUBSTANTIALLY INCREASED. 2. OPENINGS AROUND ELECTRICAL PENETRATIONS THROUGH FIRE -RESISTANCE RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE FIRESTOPPED USING APPROVED METHODS TO MAINTAIN THE FIRE -RESISTANCE RATING. 3.7. IDENTIFICATION: 1. NAMEPLATES SHALL BE FURNISHED AND INSTALLED ON THE METER CENTERS/SWITCHBOARD AND METER CENTERS/SWITCHBOARD CIRCUIT BREAKERS, PANELBOARDS, TRANSFORMERS, JUNCTION BOXES, CABINETS FOR ALL SPECIAL PURPOSE SWITCHES, MOTOR DISCONNECT SWITCHES, STARTERS AND OTHER CONTROLS FURNISHED UNDER THIS CONTRACT, TO DESIGNATE THE EQUIPMENT CONTROLLED AND FUNCTION. 2. NAMEPLATES SHALL BE LAMINATED WHITE BAKELITE WITH 1/4" HIGH BLACK RECESSED LETTERS. 3. NAMEPLATES SHALL BE SECURELY ATTACHED TO THE EQUIPMENT WITH GALVANIZED SCREWS OR RIVETS. 4. ADHESIVES OR CEMENTS WILL NOT BE PERMITTED. 5. ALL PULL BOXES AND JUNCTION BOXES SHALL BE IDENTIFIED AS TO SYSTEM AND FUNCTION BY MEANS OF BLACK FIBRE PEN. 00 O O N (V 04 U 0 PROJfCT: PINCHASERS EAST PASCO ANTHONY PERRONE 6816 GALL BOULEVARD ZEPHYRHILLS, FL 33542 PROJECT NUMBER: 21 161 I ( J N :E"' O o N U oU uj QU t 3 2 = D< u OV I ine 0 uj m -]�: x 3 O O �__ _ 10 u M ,O C) -ITN v w 1� i_ Ln �v V) = V) 0 w . wu- z U N N N z< (. Z v ujZN U 00 N in Q . a .i 'h, -'4 ..4 O ¢, . aj 9 O .� 0 n 0 O 00 N 4-+ M • '� (� M �w O U O,, p N %ar.knIn 0 rn M .r4 3 GPM* kf) kn . ,c 00 p O O = rA U U ct 0 in 4U -4--a`* N , 1�1 -0= .40�b N O% , p�/%�? M 00 STAMP: �i��+►u�r�o•st fr.r - `- ,14 r { lfw/� la � 1CTle � yV ,k. ` 1.4 i . i O.r i, 1 •: N N ;. ' l I rI J I' F -<, -ter i *r�. �,-_ I(l�i : `4 - ISSUE: DATE: ISSUED FOR PERMIT 01 /25/2023 DRAWING SCALE: NOTED DRAWN BY: SB CHECKED BY: MD DRAWING TITLE: ELECTRICAL - SPECIFICATIONS DRAWING NUMBER: