HomeMy WebLinkAbout6383 Bradford Woods DrL TM PulteGrou APPLICABLE CODES WIDTH DEPTH , SHEET LIST TABLE — THESE PLANS HAVE BEEN DESIGNED TO MEET THE REQUIREMENTS OF: —FLORIDA BUILDING CODE 6TH EDITION (2017) RESIDENTIAL —2014 NATIONAL ELECTRIC CODE —BUILDING TYPE: VB 40 -O 60)_01) LOT SPECIFIC AREA TABLE Sheet Number ISheet Title Description TOTAL. GO.01 Cover Sheet GO.02 General Notes :CONDITIONED SPACE A1.11 1st Floor Plan CMU—BASE PLAN 1850 SF A2.01 A2.02 Front Elevation & Details Side & Rear Elevations & Roof Plan 1850 SF :NON -CONDITIONED SPACE CMU—COVERED LANAI 90 SF CMU—FRONT PORCH FM1 OR C1 OR C01 21 SF CMU—GARAGE 438 SF E1.11 1st Floor Electrical Plan E1.12 P1.11 1st Floor Electrical Options 1st Floor Plumbing Plan SO.OA S1.1A _T_ 549 SF 2399 SF S1.2A S2.OA S3.OA S3.06 CONTROL DATE GENERAL NOTES LOT SPECIFIC OPTION SELECTIONS 03-23-2019 Elevation Choices Florida Mediterranean (FM102) First Floor Plate Height » 9 —4 Plate Height Kitchen Layout Choices Layout 1 Laundry Layout Choices Layout 1 Additional Hose Bib Location Rear x erior First Floor Wall Chnices CMU Exterior Wall Bath 2 Shower Choices Tub/Shower Combination Garage Handing Garage Left Garage Water Heater Choices Electric Water Heater Garage o ouse Entry Chnices Stepped Entry Garage Type Choices 2—Car Front Load Gathering oom Ueiling Flat Ceiling Owner's Bath Layout Choices Owner's Bath Layout 1 Owner's Suite Ceiling Choices Flat Ceiling Covered Lanai Covered Patio Wind Speed Choices Wind Speed 140 High e ocl y urricane Zone Non High Velocity Hurricane Configuration Choices Configuration B LOT SPECIFIED PLAN INFORMATION CustomerName * Market Home *, 6871-06301 Address 6383 BRADFORD WOODS DRIVE ZEPHRYHILLS JFL 133542 Community 6871 OAKS OF PASCO 6871-06301 ALL WORK SMAr_' CODES F fi'Ip COMPLY P A S�ri.Gl W1rH RETAILING NA71ONA ° �vr c. L cLEC;7'.PIG cone DE. OPD/NANCFS� rty` '`' �� HILLS REVIEW DATE NO 4� 0 CITY OF ZEP1-{YRHI P�,AN EXAMINER O N O N 0 U C) M M 00 cn 0 ACN a� U c� bb N as *PulteGroup- => cc O N C O w U) w M O 11 PRODUCT MANAGER RELEASE PROJECT TYPE !1• 1 T SPECIFICATION LEVEL Pulte PLAN NAME Highgate NPC CHIM NU ER 2811.500 SHEET GO,01 GENERAL NOTES — DO NOT SCALE DRAWINGS — ALL WORK MUST BE COMPLETED TO THE APPLICABLE FLORIDA BUILDING CODES — ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO A PULTE REPRESENTATIVE — CONTRACTORS SHALL MAINTAIN A CLEAN JOB SITE — CONTRACTORS ARE RESPONSIBLE TO FOLLOW ALL APPLICABLE OSHA REGULATIONS TERMITE PROTECTION — TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMICIDES AND A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT & 0 U T zfflp�PulteGl p — SOIL TREATMENT, BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD ARE ACCEPTABLE FORMS OF TREATMENT — INSPECTION FOR TERMITES o PROVIDE 6" CLEARANCE FROM GRADE WITH EXTERIOR WOOD FRAMED WALLS ■ 4' CLEARANCE REQUIRED AT GARAGES AND PORCHES EXTERIOR — WATER RESISTANCE o THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER—RESISTANT BARRIER BEHIND THE EXTERIOR VENEER AS REQUIRED BY R703.2 AND A MEANS OF DRAINING TO THE EXTERIOR WATER THAT ENTERS THE ASSEMBLY. ■ THIS IS NOT REQUIRED OVER CMU — FLASHING o APPROVED CORROSION RESISTANT FLASHING SHALL BE INSTALLED IN A SHINGLE FASHION PER R703.4 — EXTERIOR PLASTER o EXTERIOR PLASTER SHALL BE INSTALLED IN COMPLIANCE WITH ASTM C926, ASTM C1063 AND R703.7 — LATH o LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION RESISTANT MATERIALS. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1 �" LONG, 11 GAGE NAILS HAVING A 7/16' HEAD, OR 7/8" LONG, 16 GAGE STAPLES, SPACE NOT MORE THAN 6" INTO FRAMING MEMBERS 0 WEEP SCREEDS, A minimum 0.019—inch (0.5 mm) (No. 26 galvanized sheet gage), corrosion —resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 inches (89 mm) shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C926. The weep screed shall be placed not less than 4 inches (102 mm) above the earth or 2 inches (51 mm) above paved areas and shall be of a type that will allow trapped water to drain to the exterior of the building. The weather —resistant barrier shall lap the attachment flange. The exterior lath shall cover and terminate on the attachment flange of the weep screed. — SIDING o FIBER —CEMENT SIDING IS TO BE INSTALLED IN ACCORDANCE WITH ASTM C1186 AND R703.10 — MASONRY o BRICK IS TO BE INSTALLED PER R703.8 o ADHERED MASONRY IS TO BE INSTALLED PER R703.12 ROOFING — UNDERLAYMENT R905.1.1 o Unless otherwise noted underlayment for asphalt shingles, metal roof shingles, mineral —surfaced rol roofing, slate and slate —type shingles, wood shingles, wood shakes and metal roof panels shall conform to the applicable standards listed in this chapter. Underlayment materials required to comply with ASTM D226, D1970, D4869 and D6757 shall bear a label indicating compliance to the standard designation and, if applicable, type classification indicated in Table R905.1.1. Underlayment shall be applied and attached in accordance with Table R905.1.1. ■ Exception: A reinforced synthetic underlayment that is approved as an alternate to underlayment complying with ASTM D226 Type II and having a minimum tear strength in accordance with ASTM D1970 or ASTM D4533 of 20 pounds shall be permitted. This underlayment shall be installed and attached in accordance with the underlayment attachment methods of Table R905.1.1 for the applicable roof covering and slope, except metal cap nails shall be required where the ultimate design wind speed, equals or exceeds 150 mph. — FLASHING R903.2 o Flashings shall be used to seal roofing systems, where the system is interrupted or terminated and shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet walls and other penetrations through the roof plane. — ASPHALT SHINGLES SHALL BE INSTALLED PER R905.2 — CLAY AND CONCRETE TILE SHALL BE INSTALLED PER R905.3 — METAL ROOF SHINGLES SHALL BE INSTALLED PER R905.3.8 VENTILATION / ATTIC ACCESS — MIN. NET FREE VENTILATION SHALL BE 1 /150 OF THE AREA OF VENTED SPACE WHEN USING SOFFIT VENTS ONLY PER R806.2 — MIN. NET FREE VENTILATION SHALL BE 1 /300 OF THE AREA OF VENTED SPACE WHEN USING A GENERAL NOTES COMBINATION OF ROOF AND SOFFIT VENTS PER R806.2 o 40%-50% OF REQUIRED VENTILATION SHALL BE PROVIDED IN THE UPPER PORTION OF THE ATTIC LOCATED NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE. THE REMAINING VENTILATION SHALL BE OBTAINED THROUGH SOFFIT VENTS — PROVIDE MIN. 1' FREE SPACE BETWEEN INSULATION AND ROOF SHEATHING — ATTIC ACCESS IS REQUIRED WHEN THE HEIGHT IS GREATER THAN 30" AND THE AREA IS GREATER THAN 30 SF o THE HEIGHT IS MEASURED FROM THE TOP OF THE CEILING FRAMING MEMBERS TO THE BOTTOM OF THE ROOF FRAMING MEMBERS o MIN. ATTIC ACCESS SIZE IS TO BE 22'x30" WITH 30' OF UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE FIRE—RESISTANT CONSTRUCTION — DOORS FROM GARAGE TO THE RESIDENCE SHALL BE SOLID WOOD OF NOT LESS THAN 1 3/8" IN THICKNESS, SOLID OR HONEYCOMB —CORE STEEL DOOR NOT LESS THAN 1 3/8" IN THICKNESS OR A 20—MIN. FIRE —RATED DOOR — DUCTS IN THE GARAGE AND DUCTS PENETRATING WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED IN ACCORDANCE WITH R302.5.3 — X" GYP. BOARD SHALL BE INSTALLED ON GARAGE SIDE OF WALLS ABUTTING THE RESIDENCE AND GARAGE CEILING WITHOUT HABITABLE ROOMS ABOVE — 5/8" GYP. BOARD SHALL BE INSTALLED ON GARAGE CEILING W/ HABITABLE ROOMS ABOVE — %" GYP. BOARD SHALL BE INSTALLED UNDER STAIRS FOR ENCLOSED ACCESSIBLE SPACES — FIREBLOCKING SHALL BE INSTALLED PER R302.11 — DRAFTSTOPPING SHALL BE INSTALLED PER R302.12 AND SHALL NOT EXCEED 1,000 SF. DRAFTSTOPPING SHALL DIVIDE THE SPACE IN APPROXIMATELY EQUAL AREAS WINDOWS/DOORS — FIELD SHALL VERIFY ALL WINDOW/DOOR ROUGH OPENINGS — PROVIDE EMERGENCY ESCAPE AND RESCUE WINDOW OR DOOR IN ALL BEDROOMS PER R310 o (*) DENOTES WINDOW SHALL COMPLY WITH EMERGENCY ESCAPE AND RESCUE (EERO) REQUIREMENTS o OPENINGS SHALL NOT BE LESS THAN 5.7 SF WITH A NET CLEAR OPENING OF MIN. 24" H AND MIN. 20' D o EERO WINDOW SILLS SHALL BE INSTALLED NO MORE THAN 44' A.F.F. — ONE EGRESS DOOR SHALL BE PROVIDED PER DWELLING UNIT WITH A CONTINUOUS AND UNOBSTRUCTED PATH WITHOUT GOING THROUGH A GARAGE o MIN. CLEAR WIDTH 32" WHEN OPEN AT 90 DEGREES o MIN. HEIGHT 78" o FINISHED FLOOR SHALL BE MAX. 1 1 /2" BELOW TOP OF THRESHOLD o PORCH SHALL BE MAX. 7-3/4" BELOW TOP OF THRESHOLD FOR IN —SWING DOORS — OPENINGS SHALL BE PROTECTED IN WIND —BORN DEBRIS AREAS IN ACCORDANCE WITH R301.2.1.2 — TEMPERED GLASS SHALL BE INSTALLED WITH THE FOLLOWING o FIXED AND OPERABLE PANELS IN DOORS ■ GLAZING WITHIN 24' OF EITHER SIDE OF DOOR IN THE PLANE OF THE DOOR IN A CLOSED POSITION ■ GLAZING IS ON A WALL PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION AND WITHIN 24' OF THE HINGE SIDE OF AN IN —SWING DOOR. o WINDOWS ■ GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION: • WHEN EXPOSED AREA IS OVER 9 SF • BOTTOM EDGE OF GLAZING IS LESS THAN 18' A.F.F. • THE TOP EDGE OF THE GLAZING IS MORE THAN 36 INCHES (914 MM) ABOVE THE FLOOR; AND • ONE OR MORE WALKING SURFACES ARE WITHIN 36 INCHES (914 MM), MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING o WINDOWS ADJACENT TO THE BOTTOM STAIR LANDING ■ WHEN BOTTOM EDGE OF GLAZING IS LESS THAN 36" ABOVE THE PLANE OF THE WALKING SURFACE ■ WHEN GLAZING IS WITHIN 60" OF BOTTOM STAIR LANDING o WET AREAS ■ GLAZING IN WALLS OR ENCLOSURES CONTAINING OR FACING HOT TUBS, SPAS, BATHTUBS, SHOWERS OR SWIMMING POOLS SHALL BE TEMPERED IF SILL HEIGHT IS LESS THAN 60" A.F.F., MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. ■ SHOWER AND/OR TUB ENCLOSURES SHALL BE TEMPERED WOOD — ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE —PRESERVATIVE —TREATED WOOD INSULATION — INSULATION SHALL BE INSTALLED PER APPROVED LOT SPECIFIC ENERGY CALCULATIONS — INSULATE, THERMO—PLY AND SEAL AREAS BEHIND TUBS OR SHOWERS ON EXTERIOR WALLS — INSTALL WOOD SHEATHING OR THERMO—PLY ON ATTIC SIDE WHEN CONDITIONED SPACE ABUTS UNCONDITIONED ATTIC SPACE TO CREATE A 6—SIDED INSULATION ASSEMBLY DRYWALL — 1h' SAG —RESISTANT GYPSUM CEILING BOARD SHALL BE USED ON CEILINGS WITH 24" O.C. SPANS ACCESSIBILITY — ONE BATHROOM LOCATED ON HABITABLE GRADE LEVELS SHALL PROVIDE A DOOR THAT HAS A 29" CLEAR OPENING PER R320.1.1. A POWDER BATH CAN BE USED IF THERE ARE NO BATHS ON THE GROUND FLOOR WITH A TUB OR SHOWER o ALL DOORS LEADING TO THE BATHROOM INCLUDING PRIVATE WATER CLOSET DOORS SHALL MEET THIS REQUIREMENT. o CLEAR OPENING CAN BE ACHIEVED WITH A 2/8 SWING DOOR OPENED AT 90 DEGREES OR A 2/6 POCKET DOOR SITE ADDRESS — BUILDINGS SHALL BE PROVIDED WITH APPROVED ADDRESS IDENTIFICATION. THE ADDRESS SHALL BE NO LESS THAN 4' IN HEIGHT AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY GUARDS AND WINDOW FALL PROTECTION — GUARDS SHALL BE PROVIDED WHEN WALKING SURFACES ARE LOCATED MORE THAN 30" ABOVE GRADE (WITHIN 24" HORIZONTALLY) OR A.F.F. — GUARDS SHALL BE MIN. 36' o EXCEPTION: 34' IS ALLOWED IF THE TOP OF THE GUARD SERVES AS A HANDRAIL ON THE OPEN SIDE OF THE STAIRS — GUARDRAILS SHALL NOT INCLUDE OPENINGS THAT WILL ALLOW THE PASSAGE OF A 4" SPHERE — WINDOWS WHERE THE TOP OF THE SILL IS LESS THAN 24" A.F.F. AND GREATER THAN 72' ABOVE FINISHED GRADE OF OTHER SURFACE SHALL HAVE A WINDOW OPENING CONTROL DEVICE INSTALLED STAIRS — MIN. CLEAR WIDTH 36" o HANDRAILS SHALL NOT PROJECT MORE THAN 4 1h" ON EITHER SIDE OF THE STAIRWAY — MIN. HEADROOM 6'-8" — MAX. RISE 7-3/4" — MIN. TREAD DEPTH 10" — HANDRAILS o 34"-38" ABOVE SLOPE PLANE 0 HANDRAILS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT ON STAIRWAYS OF MORE THAN FOUR RISERS 0 1 1/V-2" GRIP SIZE OR GRASPABLE FINGER RECESS ELECTRICAL — SMOKE ALARMS COMPLYING WITH NFPA 72 SHALL BE INSTALLED: o IN EACH SLEEPING ROOM o OUTSIDE EACH SLEEPING ROOM o ON EACH ADDITIONAL STORY o CANNOT BE INSTALLED WITHIN 3' HORIZONTALLY OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER — SMOKE ALARMS SHALL BE HARD —WIRED W/ BATTERY BACKUP AND INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS o COMBINATION SMOKE/CARBON MONOXIDE ALARMS ARE PERMITTED — THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE — GROUND —FAULT CIRCUIT PROTECTION; ALL 120V SINGLE PHASE, 15 & 20 AMP OUTLETS INSTALLED OUTDOORS, IN BATHROOMS, IN KITCHENS, GARAGES, LAUNDRY AND AT DISHWASHER SHALL HAVE GFCI CIRCUIT BREAKERS OR RECEPTACLES — BRANCH CIRCUITS THAT SUPPLY 120—VOLT, SINGLE PHASE, 15 & 20 AMP OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED WITH ARC —FAULT CIRCUIT —INTERRUPTER PROTECTION PER FBCR E3902.16 AND SHALL BE LISTED AS TAMPER —RESISTANT — NOT LESS THAN 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH —EFFICACY LAMPS OR NOT LESS THAN 75 PERCENT OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH —EFFICACY LAMPS a O CV O N 2 CD 0 ail W M 0 UJ .o A� N U Cf N � *PulteGrour PRODUCT MANAGER RELEASE DATE: xx/xx/xxxx PROJECT TYPE /1• 1 T SPECIFICATION LEVEL I Pulte PLAN NAME Highgate NPC CHIM NU ER 2811.500 SHEET GO.02 c 2 FIRST FLOOR PLAN SCALE 1 /4" = 1'—O" (NOTE: SCALE 1 /8" = 1'—O" ON 1107 PAPER) An'_n" LEGEND MASONRY — CONC. BLOCK OR BRICK WALL 2X FRAME WALL PER PLAN ot ELEV. ELEVATION INDICATOR — ELEVATION NOTED IS RELATIVE TO FINISH FLOOR DATUM = 0'-0" �C DENOTES EMERGENCY ESCAPE & RESCUE OPENING 7-1/4' DROPPED CEILINGS ARE TO BE FIELD FRAMED DOWN FRAME DOWN FROM THE BOTTOM OF THE TRUSSES 7-1/2" U.N.O. 12T CEILING TRAYS ARE TO BE RECESSED INTO THE TRAY UP TRUSSES 12" U.N.O. ALL DIMENSIONS ARE TO THE ROUGH UNLESS NOTED OTHERWISE. —2x4 WALLS ARE DRAWN 3 1/2" THICK —2x6 WALLS ARE DRAWN 5 1/2" THICIt —8" BLOCK WALLS WITH FURRING ARE DRAWN 9" THICK INCLUDING FURRING c5 cV CN cD RE U l'J � 00 0 VJ � O O 00 Aulli U� 'IC$ 0 N � lItputte 0 - 0 o � �♦ M 0 O N �"'♦ 00 r~''' '� C) C) 0 x �2 PRODUCT MANAGER IRELEASE Mir. vv /vv /Vvvv PROJECT TYPE I Single Familv SPECIFICATION LEVEL I Pulte PLAN NAME Highgate NPC CHIM NUMER 2811.500 SHEET A1.11 U ,-� 8,_0. T.O. WDW FRONT ELEVATION SCALE 1 /4" = 1'-0" (NOTE: SCALE 1 /8" = 1'-O" ON 11 x17 PAPER) FW- FYPON COROG 8X6X4 OR APPROVED EQUAL tD I CORBEL DTL El rA C N J4" TRIM DETAIL SCALE: 1/2' = V4 FRIEZE BANDING DTL SCALE: 1/2' = V4 N GARAGE DOOR 4" TRIM DETAIL SCALE 1/2' = V4 r� 00 O 0 VJ O O c\ T A a, v V �o N as AItPutte 0 O 00 � � H � � W Q � N Z o � � W W � W o T go a� pL1 O o M P4 PRODUCT MANAGER RELEASE PROJECT TYPE I Single Family SPECIFICATION LEVEL Pulte PLAN NAME Hi h ate NPC CHU NU ER 2811.500 SHEET A2,01 3 0 a 0 O 0 cn 0 W C CV 0 cV CD 0 CV O N 0 U 0 W -ATTIC VENTILATION - ACTUAL ATTIC AREA TOTAL FREE VENT TOTAL REQUIRED (AREA/ 300) SQ. FT. SQ, IN. SQ. FT. Q. IN. 2399 345456 7.997 1151.520 ROOF VENTS SOFFTT VENTS REQUIRED REQUIRED (SI/6.17) SQ. FT. SQ. IN. VENTS OF SQ. FT. SQ. IN. LIN. FT. 3.199 460.608 4 4.798 690.912 112 ROOF TOP ATTIC VENT: SOFFIT VENT TYPE: SERIES CONTINUOUS 121 = 1 SQ. FT./ VENT SOFFIT VENT = 6.17 SQ. IN. (121 SQ. IN. VENT) AREA PER LINEAR FT. NOTE: RIDGE VENTS MAY BE SUBSTITUTED PER MUNICIPALITY ROOF PLAN SCALE 1 /8" = 1'—O" (NOTE: SCALE 1 /16" = 1'—O" ON 11 x17 PAPER) o� T.O. WDW co N_n' A. 0 ------ OPT. 4' BANDING 1 OPT. GMDS PER COti1MUNITY SPEC REAR ELEVATION SCALE 1 /8" = 1'-0" (NOTE: SCALE 1 /16" = 1'—O" ON 11x17 PAPER) TRUSS BEARING TRUSS\ 9'-4" 9'-4" ----------------- -- - ---------- 8 —0 ® — T.O. WDW I CD '-0 i T.O. WDW , 0 , o ; F__i_ 00 0o OPT. GRIDS PER rnco OPT SAND FlNISHED `--------- .GRIDS PER �--------------� J COMMUNITY SPEC SAND FINISHED „ OPT. 4" BANDING „ STUCCO OPT. 4 BANDING COMMUNITY SPEC FINISH �00 STUCCO FINISH 0 —0 SIDE ELEVATION SCALE 1 /8" = 1'-0" (NOTE: SCALE 1 /16" = 1'—O" ON 11 x17 PAPER) SIDE ELEVATION SCALE 1 /8" = 1'-0" (NOTE: SCALE 1 /16" = 1'—O" ON 11 x17 PAPER) O c'h l'J � v °Q M 0 Uri � O O A� v a` v� V� cz • 'O � r-I L. llkPulteGroup- z o C M o v Q N W o as � W o � o m A � 00 m f PRODUCT MANAGER RELEASE DATE: xx /xx /xxxx PROJECT TYPE �1• 1 T SPECIFICATION LEVEL I Pt lte PLAN NAME Highgate NPC CHID NU R .2811.500 SHEET A2.02 1 ' MID FIRST FLOOR ELECTRICAL PLAN SCALE 1 /4" = 1'-0" (NOTE: SCALE 1 /8" = 1'-O" ON 11 x17 PAPER) 11 ELECTRICAL SYMBOLS I 0 STANDARD AFCI 110 OUTLET (TAMPER RESISTANT) f—I STANDARD AFCI 110 OUTLET - 1/2 SWITCHED (TAMPER RESISTANT) #GFq STANDARD 110 OUTLET - GROUND FAULT CIRCUIT INTERRUPTER OW/GFCISTANDARD 110 OUTLET - WATERPROOF / G.F.C.I. ® SWITCHED FLOOR OUTLET 220V STANDARD AFCI 220 OUTLET ®DW DISHWASHER OUTLET (GFCI PROTECTED) s f 4 $ SWITCH, SWITCH = 3-WAY, SWITCH = 4-WAY LIGHT FIXTURE - CEILING MOUNT LIGHT FIXTURE - WALL MOUNT © LIGHT FIXTURE - PENDANT -0-PC LIGHT FIXTURE - PULL CORD LIGHT FIXTURE - COACH LIGHT - LIGHT FIXTURE - EXTERIOR WALL MOUNT { }R LIGHT FIXTURE - LED DOWNLIGHT - / LIGHT FIXTURE / VAPOR PROOF LIGHT FIXTURE / EXTERIOR FLOOD LIGHT ' LIGHT FIXTURE / FAN COMBINATION (EXTERIOR VENTED) O EXHAUST FAN (EXTERIOR VENTED) O CAPPED PLATE LIGHT FIXTURE - 48" FLUORESCENT OPTIONAL PADDLE FAN / LIGHT COMBINATION PREWIRE PROVIDE FRAMING SUPPORT FOR FIXTURE SO SMOKE DETECTOR �� ELECTRIC PANEL (AFa PROTECTED) ® SMOKE/CARBON Et METER MONOXIDE COMBO cS DISCONNECT DETECTOR (AFCI PROTECTED) EMERGENCY LIGHT -0PB THERMOSTAT PUSH BUTTON TELEVISION OUTLET SWITCH CHIMES TELEPHONE OUTLET /O/ C�ApBPRoEFDIp DISPOSAL °� DOOR BELL CHIMES (GARAGE DOOR 0 WIFI HOTSPOT OPENER DATA/TV MEDIA /SWP BOX DATA /TV OUTLET ELECTRIC MOUNTING HEIGHTS STANDARD RECEPTACLES INTERIOR 18" AFF STANDARD RECEPTACLES EXTERIOR 18" AFF STANDARD SWITCHES 44" AFF DEDICATED OUTLET FOR WASHER AND DRYER 32" AFF MICROWAVE / RANGE HOOD 78' AFF BUILT-IN MICROWAVE 66" AFF 0 150 AMP 42 METER CIRCUIT MAIN CIRCUIT BREAKER #4 COPPER 1---2" PVC CONDUIT 1/2" PVC 2-2/0 COPPER OR 2-4/0 ALUMINUM PVC 1-1/0 COPPER 1-3/0 ALUMINUM ELECTRICAL RISER DIAGRAM NOT TO SCALE 4/0 SER CABLE 150 AMP O COMBINATION SERVICE 120-240 VOLT DISCONNECT SWITCH AND 1 PHASE MLO 200 AMP 2PH ELECTRIC METER IN NEMA PANEL uro 3R ENCLOSURE INTERSYSTEM BONDING TERMINAL AT LOW VOLTAGE CONNECTIONS — I 114 SERVICE GROUND CONNECTED TO CONCRETE - ENCASED STEEL ELECTRICAL RISER DIAGRAM NOT TO SCALE ALTERNATE W M ouo)� N O A� U� • •o F 3; i tz N C) lliPultoGroup- cn M �c a U Q N U a w � cn o W -� O 0 0 a, w cn xcn U) PRODUCT MANAGER RELEASE PROJECT TYPE A• 1 T SPECIFICATION LEVEL I Nte PLAN NAME .Highgate NPC CH NUR 2811.500 SHEET E1.11 r 01 3 0 0 0 U N W 0 0 W 0 0 C'4 O CV 0 0 0 a P. 6 . /1 / 1 I / / / / / / / / I / / / / / / / / i , / 1 1 1 1 1 / 1 1 / 1 i 1 1 I I I 1 1 1 1 , , 1 , 1 i 1 1 1 1 1 1 1 11 1 1 1 \ \ \ \ \ \ \ \ \ \ / O / o I A CV Z' 1 1 \ \ \ Q N ` c O O i��,-'� / i rn I ■ M , r \ Q\ ` C ------ -------------------- 0 0 0 i Al/Viva '1d0L 11 FIRST FLOOR ELECTRICAL OPTIONS SCALE 1 /4" = 1'-0' (NOTE: SCALE 1 /8" = 1'-O" ON 11 x17 PAPER) F1: a�•�a '1dO cq O ~ l7 Ir- O , II� , CMI ------- 69 O W m W •D 0 ld0 Z " � J � W v ----------------- / / / W ' C3 " , I�X�I L — 1 U' N \ 0 z I.UL , 1\ 1\ 1\ 1 , „ 1 � 1 ` 1 \ 1 ` 1 ` 1 ` 1 ` 1 ` 1 ` 1 ` 1 ` 1 ` 1 ` I ` 1 ` 1 ` 1 '1 1 , 1 , I , 1 , I 1 ; 1 , / I i 1 1 1 1 1 1 , I I 1 1 1 I 1 1 I i I 1 I I 1 I / / 1 ' 1 ' , 1 1 ' 1 ' 1 ' 1 ' 1 ' 1 ' 1 ' 1 ' 1 ' 1 ' 1 ' 1 ' 1 ' I ' 1 ' 1 ' 1 ' , 1 1 ' 1 ' 1 ' I ' I ' I ' 1 ' 1 ' I ' 1 ' 1 ' 1 ' 1 ' 1 ' 1 ' I ' 1 ' 1 ' 1 ' I 1 1 1 ' U I (' I I� 0 V) Z 2'-0" TYP. SPACINI METAL STUD, TYP. 2'-Oa '. SPACING END NAILS, TYP. —2x4 WOOD BLOCKING INSIDE METAL LWOOD BLOCKING STACKED BETWf TRACK, FROM BOTTOM PLATE TO TOP BLOCKED METAL STUDS PLATE, TYP. e ,--METAL STUD, TYP. 2x6 WOOD STACKED BETWEEN BLO CKED METAL STUDS, TYP. WOOD BLOCKING INSIDE METAL TRACK, FROM_\p BOTTOM PLATE TO TOP 0 PLATE od" > > LOCATION ,%,LOCATION i l 2" CONDUIT CHASE TO RUN DOWN TO BOX ADJACENT TO STANDARD DUAL MEDIA OUTLET TV WALL MOUNT BRACING S CA-LE: N.T.S. n ELECTRICAL SYMBOLS 11 0 STANDARD AFCI 110 OUTLET (TAMPER RESISTANT) STANDARD AFCI 110 OUTLET - 1/2 SWITCHED (TAMPER RESISTANT) oCI STANDARD 110 OUTLET - GROUND FAULT CIRCUIT INTERRUPTER ONP/GFCISTANDARD 110 OUTLET - WATERPROOF / G.F.C.I. ® SWITCHED FLOOR OUTLET §220V STANDARD AFCI 220 OUTLET ®DW DISHWASHER OUTLET (GFCI PROTECTED) SWITCH, SWITCH = 3-WAY, SWITCH = 4-WAY LIGHT FIXTURE - CEILING MOUNT LIGHT FIXTURE - WALL MOUNT © LIGHT FIXTURE - PENDANT �pc LIGHT FIXTURE - PULL CORD F@ LIGHT FIXTURE - COACH LIGHT LIGHT FIXTURE - EXTERIOR WALL MOUNT R - LIGHT FIXTURE - LED DOWNLIGHT -- LIGHT FIXTURE / VAPOR PROOF L3 LIGHT FIXTURE / EXTERIOR FLOOD LIGHT LIGHT FIXTURE / FAN COMBINATION (EXTERIOR VENTED) O EXHAUST FAN (EXTERIOR VENTED) O CAPPED PLATE LIGHT FIXTURE - 48" FLUORESCENT OPTIONAL PADDLE FAN / LIGHT COMBINATION PREWIRE .7?1'r;`.� v v PROVIDE FRAMING SUPPORT FOR FIXTURE QS SMOKE DETECTOR OEP ELECTRIC PANEL PROTECTED) © SMOKE/CARBON SMOKE/CARBON � ELECTRIC METER MONOXIDE COMBO cS DISCONNECT DETECTOR (AFCI PROTECTED) EMERGENCY LIGHT ® --SPB THERMOSTAT PUSH BUTTON TELEVISION OUTLET SWITCH CHIDES TELEPHONE OUTLET GARBAGE DISPOSAL (GFCI PROTECTED) P9 DOOR BELL CHIMES GARAGE DOOR 0 WFl HOTSPOT OPENER DATA/ MEDIA /SWP BOX DATA TV OUTLET ELECTRIC MOUNTING HEIGHTS STANDARD RECEPTACLES INTERIOR 18" AFF STANDARD RECEPTACLES EXTERIOR 18" AFF STANDARD SWITCHES 44" AFF DEDICATED OUTLET FOR WASHER AND DRYER 32" AFF MICROWAVE / RANGE HOOD 78" AFF BUILT-IN MICROWAVE 66" AFF NOTE: MOUNTING HEIGHTS ARE TO THE CENTER 0 150 AMP 42 CIRCUIT MAIN METER CIRCUIT BREAKER #4 COPPER L—2" PVC CONDUIT 0 1/2" PVC 2-2/0 COPPER OR 2-4/0 ALUMINUM PVC 1-1/0 COPPER 1-3/0 ALUMINUM I I III IIII ELECTRICAL RISER DIAGRAM NOT TO SCALE 4/0 SER CABLE 150 AMP O COMBINATION SERVICE 120-240 VOLT DISCONNECT SWITCH AND I 1 PHASE MLO 200 AMP 2PH ELECTRIC METER IN NEMA PANEL urR 3R ENCLOSURE INTERSYSTEM BONDING TERMINAL AT LOW VOLTAGE CONNECTIONS �L III III III III _II II II III; — I ( 1#4 SERVICE GROUND _ CONNECTED TO CONCRETE — ENCASED STEEL ELECTRICAL RISER DIAGRAM NOT TO SCALE ALTERNATE 0 C'4 0 N 2 0 U u CO CO W 00 cn •� C 0 � �MM N U co 0 �a N 0 *PulteGroup- C) y � � O C � 00 PRODUCT MANAGER RELEASE DATE: XX /XX /XXXX PROJECT TYPE Single Famfl SPECIFICA11ON LEVEL Pulte PLAN NAME Hanover NPC CHILD NUMBER 2811.500 SHEET THIS PLAN IS INTENDED FOR PLUMBING FIXTURE LOCATIONS ONLY FIRST FLOOR PLUMBING PLAN SCALE 1 /4" = 1'-0" (NOTE: SCALE 1 /8" = 1'-O" ON 11 x17 PAPER) ILI] O 4� °Q M 0 vJ 0 A Q, Q� U� ct� coo cn � litPultoGroup- cn PRODUCT MANAGER IRELEASE I DATE: XX /XX /XXXX PROJECT TYPE Sinele Family SPECIFICATION LEVEL I Pulte PLAN NAME Highgate NPC CHIM NU ER 2811.500 SHEET pill A. GENERAL: 1. WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE FOLLOWING CODE: FLORIDA RESIDENTIAL BUILDING CODE 6th EDITION (2017). WHERE MORE STRINGENT CODES ARE ADOPTED, THEY SHALL GOVERN THE WORK. 2. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON DRAWINGS. NOTES ON STRUCTURAL PLANS SHALL TAKE PRECEDENCE OVER THE STRUCTURAL GENERAL NOTES ON THIS SHEET. 3. EXCEPT AS SHOWN ON STRUCTURAL DRAWINGS, REFER TO ARCHITECTURAL, ELECTRICAL PLUMBING AND MECHANICAL DRAWINGS FOR DIMENSIONS, LOCATIONS, SIZES AND CONDITIONS, INCLUDING WINDOWS, DOORS, WALLS, CONCRETE CURBS, PITS, DRAINS, TRENCHES, FLOOR AND ROOF SLOPES, DEPRESSED AREAS, CHANGES IN LEVEL, FLOOR AND ROOF OPENINGS, STAIRS, PIPE AND DUCT RUNS, SLEEVES AND HANDERS, ELECTRICAL, CONDUITS AND OUTLETS, ITEMS EMBEDDED OR ATTACHED TO STRUCTURAL MEMBERS, EQUIPMENT, BASES AND ANCHORAGE, ETC. 4. THE ENGINEER'S SEAL APPUES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. THE SEAL DOES NOT INCLUDE CONSTRUCTION MEANS, METHODS, TECHNIQUES, OR SAFETY PRECAUTIONS, WHICH SHALL REMAIN THE RESPONSIBILITY OF THE CONTRACTOR. ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS ANY DEVIATIONS OR DISCREPANCIES ON THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER OF RECORD. 5. ASTM SPECIFICATIONS INDICATED SHALL BE THE LATEST EDITIONS OF THE STANDARDS, UNLESS NOTED OTHERWISE. 6. ALTERNATE NAILING: PASLODE FASTENERS MAY BE USED ON SIMPSON HARDWARE. REFER TO SIMPSON TECHNICAL BULLETIN T-POSITIVENLO& POSITIVE PLACEMENT NAIL APPLICATIONS WITH PASLODE FASTENERS. B. DESIGN CRITERIA: 1. DESIGN LOADS: ROOF DEAD LOADS METAL ROOF TC DEAD LOADS 10.0 PSF SHINGLE ROOF TC DEAD LOADS 7.0 PSF TILE ROOF TC DEAD LOADS 15.0 PSF ROOF BC DEAD LOADS 10.0 PSF ROOF LIVE LOADS TC LIVE LOAD 20.0 PSF (REDUCIBLE) BC LIVE LOAD w/o STORAGE 10.0 PSF BC LIVE LOAD w/ STORAGE 20.0 PSF FLOOR DEAD LOADS 11.0 PSF WOOD FRAMED DEAD LOAD 11.0 PSF FLOOR LIVE LOADS 40.0 PSF (REDUCIBLE) BALCONY DEAD LOAD 15.0 PSF BALCONY LIVE LOAD 60.0 PSF EXTERIOR WD WALL 18.0 PSF INTERIOR WD WALL 7.0 PSF STAIRS/LANDING 40.0 PSF WIND SPEED PER ASCE 7-10 140 MPH (THE NOMINAL WIND SPEED SHOWN HAS BEEN BASED ON LINEAR INTERPOLATION OF THE SITE LOCATION) INTERNAL PRESSURE COEFFICIENT +/- 0.18 (FULLY ENCLOSED STRUCTURE) RISK CATEGORY II EXPOSURE 'C' 2. ALL GUARDRAILS AND HANDRAILS SHALL MEET THE MINIMUM CODE REQUIREMENT WITHSTANDING A MINIMUM 200 POUND CONCENTRATED POINT LOAD APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP. ALL IN -FILL COMPONENTS OF THE GUARDRAIL SHALL BE DESIGNED TO WITHSTAND A MINIMUM HORIZONTALLY APPLIED NORMAL LOAD OF 50 POUNDS ON AN AREA EQUAL TO 1 SQUARE FOOT. THESE LOADS ARE TO BE EVALUATED INDEPENDENTLY AND ARE NOT ASSUMED TO ACT CONCURRENTLY WITH ANY OTHER LIVE LOAD. DEFLECTION OF THIS GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICES (ICC-ES) AC273 - ACCEPTANCE CRITERIA FOR HANDRAILS AND GUARDS. C. FOUNDATION: 1. FOUNDATION IS DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. THE CONTRACTOR SHALL VERIFY THAT THE MINIMUM BEARING CAPACITY OF 2000 PSF. IS PRESENT PRIOR TO FOOTING PLACEMENT. 2. ALL ALL SHALL BE CLEAN AND COMPACTED TO 95% BY HEAVY VIBRATORY ROLLER IN MAXIMUM LIFTS OF 8". CONFORM TO ASTM D 1557. 3. GRADING, SOIL PREPARATION AND FOUNDATION CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS OF THE GEOTECHNICAL REPORT AND THE BUILDING CODES NOTED ON THIS SHEET. 4. FOOTING BACKALL AND UTILITY TRENCH BACKRLL WITHIN BUILDING AREA SHALL BE MECHANICALLY COMPACTED IN LAYERS PER GEOTECHNICAL REPORT. FLOODING WILL NOT BE PERMITTED. 5. ABANDONED FOOTINGS, UTILITIES, ETC. THAT INTERFERE WITH NEW CONSTRUCTION SHALL BE REMOVED. 6. PROVIDE MIN. 6 MIL APPROVED VAPOR BARRIER. ALL JOINTS TO BE LAPPED MIN. 6' AND SEALED. D. CONCRETE: 1. CONCRETE SHALL CONFORM TO THE 'BUILDING REQUIREMENTS FOR REINFORCED CONCRETE' (ACI 318 LATEST EDITION) WITH MODIFICATIONS AS NOTED IN THE DRAWINGS AND SPECIFICATIONS. 2. DESIGN BASED ON 2500 PSI, 28-DAY STRENGTH, UNLESS OTHERWISE NOTED. 3. PROTECTION COVER (CLEAR) SHALL BE AS FOLLOWS (U.N.O.): a. CONCRETE PLACED DIRECTLY AGAINST EARTH - 3 INCHES CLEAR b. STRUCTURAL SLABS ON GROUND - 1 1/2 INCHES CLEAR c. FORMED CONCRETE WITH EARTH BACK ALL - 2 INCHES CLEAR d. WWM USED IN SLABS SHALL BE FULLY SUPPORTED USING CHAIR APPROVED BY THE MANUFACTURER IN THE MIDDLE TO UPPER � OF SLAB AT 3-FT SPACING OR IN ACCORDANCE w/MANUFACTURER'S SPECIFICATIONS 7. ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. 8. PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE BEFORE PLACING. DO NOT CUT ANY REINFORCING WHICH MAY CONFLICT. 9. CONCRETE PLACEMENT SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301, ACI 318 & ACI 332. 10. SLABS ARE DESIGNED AS UNREINFORCED PLAIN CONCRETE SLABS ON GROUND. 11. ONE OF THE FOLLOWING METHODS OF CRACK CONTROL SHALL BE USED: a.) CONTRACTION JOINTS. IF CONTRACTION JOINTS ARE USED, THEY SHALL BE CUT OR TOOLED IN THE SLAB A MINIMUM OF 1'. ALL SAW CUTS ARE TO BE MADE WITHIN 24 HOURS OF THE CONCRETE PLACEMENT. CONTRACTION JOINTS IN A 3.5' SLAB SHALL BE PLACED NO MORE THAN 8-FEET APART IN BOTH DIRECTIONS CONTRACTION JOINTS IN A 4.0' SLAB SHALL BE PLACED NO MORE THAN 10-FEET APART IN BOTH DIRECTIONS b.) 6x6 W1.4xW1.4 WELDED WIRE REINFORCEMENT FABRIC (WWI). c.) MICRO- OR MACRO-SYNTHECTTC FIBER REINFORCEMENT. FIBER LENGTHS SHALL BE J� TO 2 N IN LENGTH. DOSAGE AMOUNTS SHALL BE FROM 0.75 TO 3.0 POUNDS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE CERTIFICATION OF COMPLIANCE WITH ASTM C1116 WHEN REQUESTED BY THE BUILDING OFFICIAL E. MASONRY WALL CONSTRUCTION: 1. MASONRY CONSTRUCTION SHALL COMPLY WITH LATEST EDITION OF TMS 402 & 602 / ACI 530 & 530.1 / ASCE 5 & 6. 2. MASONRY UNITS SHALL MEET ASTM C-90, GRADE N-1 FOR HOLLOW LOAD BEARING TYPE II MASONRY WITH UNIT STRENGTH OF 1,900 psi ON THE NET AREA (fm = 1,500 psi). UNITS SHALL BE NORMAL WEIGHT, 8' x 8' x 16', TWO HOLE, SQUARE END BLOCKS UNLESS NOTED OTHERWISE. UNITS SHALL HAVE A ROUGH TEXTURE FOR STUCCO APPLICATION. 3. ALL MORTAR SHALL CONFORM TO ASTM C 270, TYPE 'S' OR 'M'. 4. COURSE GROUT SHALL CONFORM TO ASTM C476 NTH A MAXIMUM AGGREGATE SIZE OF 3/8' AND A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI. 5. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS, WITH FILLED CELLS FILLED WITH COURSE GROUT. 6. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE TOP AND THE BOTTOM AND AT A MAXIMUM SPACING OF 8'-0' U.N.O. REINFORCEMENT SHALL BE PLACED IN THE CENTER OF THE MASONRY CELL, TYPICAL, UNLESS OTHERWISE NOTED. 7. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. 8. ALL MASONRY UNITS SHALL BE LAID IN RUNNING BOND U.N.O. 9. OVER ALL MASONRY OPENINGS IN WALLS PROVIDE LINTELS, CAST -IN -PLACE CONCRETE BEAMS, OR OTHER HEADERS AS NOTED ON PLANS. 10. VERTICAL FILLED CELLS SHALL HAVE A MINIMUM OF (1) #'5 BAR LAPPED AND TIED TO THE FOUNDATION DOWEL, AND A STANDARD ACI HOOK AT THE TOP, LAPPED AND TIED TO THE HORIZONTAL REINFORCING IN THE TOP OF THE WALL SEE CHART BELOW FOR MINIMUM LAP AND HOOK LENGTHS. REINFORCING STEEL MINIMUM REQUIREMENTS BAR SIZE MINIMUM LAP MINIMUM BEND DIA. MINIMUM ACI HOOK 14 20' 3' 10' #5 25' 3-3/4' 10' #6 34' 4-1/2' 11' f7 42' 5-1/4' 13' F. REINFORCING STEEL: 1. WALL BARS AND COLUMN BARS SHALL CONFORM TO ASTM A-615, GRADE 60. FOOTING BARS AND BOND BEAM BARS SHALL CONFORM TO ASTM A-615, GRADE 40 OR GRADE 60. 2. BAR BENDS SHALL BE MADE COLD, IN STRICT ACCORDANCE WITH THE DRAWINGS AND C.R.S.I. LATEST EDITION. NO KINKS ALLOWED. SEE CHART FOR STANDARD HOOK SIZES. 3. REBAR LAP SPLICES ARE TO BE: CLASS 'B'. MINIMUM LAP LENGTH SHALL BE PER CHART UNLESS NOTED OTHERWISE. MINIMUM LAP OF WELDED WIRE FABRIC SHALL BE 6 INCHES OR ONE FULL AND HALF MESH, WHICHEVER IS GREATER. 4. FIELD WELDING OF REINFORCING BARS IS NOT PERMITTED, UNLESS NOTED OTHERWISE. 5. DOWELS BETWEEN FOOTINGS SHALL BE THE SAME SIZE AND SPACING OR NUMBER AS THE HORIZONTAL REINFORCING. 6. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME SIZE AND SPACING OR NUMBER AS THE VERTICAL REINFORCING. 7. TOLERANCE FOR REBAR DEPTH AND CONCRETE COVER IN FLEXURAL MEMBERS, WALLS, DISCONTINUOUS ENDS OF MEMBERS, AND COMPRESSION MEMBERS SHALL BE AS FOLLOWS TOLERANCE ON d TOLERANCE ON SPECIFIED CONCRETE COVER d<=8 in +/- 3/8' -3/8' d>=8 in +/- 1/2' -1/2' TOLERANCE FOR LONGITUDINAL LOCATION PLACEMENT OF BENDS AND ENDS OF REINFORCEMENT SHALL BE +/- 2' G. WOOD FRAMING: 1. FRAMING LUMBER SHALL BE SURFACE DRY AND USED AT 19% MAXIMUM MOISTURE CONTENT. ALLOWABLE STRESS REQUIREMENTS OF ALL WOOD MEMBERS SHALL BE IN ACCORDANCE WITH THE 2015 EDITION OF THE NDS. 2. EXTERIOR WALL LUMBER, U.N.O. ON THE PLANS, 2x4 (MIN) SPF OR SP NUMBER 2 OR BETTER 016' O.C. FOR WALLS 9'-5' OR LESS. 3. INTERIOR LOAD BEARING WALLS SHALL BE 2x4 SPF OR SP NUMBER 2 OR BETTER 016' O.C. MAX. (U.N.O.). 4. INTERIOR NON -LOAD BEARING WALLS SHALL BE 2x4 SPF, SP, OR METAL STUDS 0 24' O.C. MAX. 5. LUMBER IN CONTACT WITH GROUND, CONCRETE, OR MASONRY SHALL BE SOUTHERN PINE PRESSURE TREATED. 6. HEADER FRAMING: a.) HEADER SIZES SPECIFIED ON SCHEDULES AND/OR PLANS ARE MINIMUM REQUIREMENTS AND CAN BE UPGRADED TO LARGER SIZE OF SAME SPECIES, GRADE AND PLY COUNT. b.) FOR 2x4 STUD WALL PROVIDE: (1) 2x4 KING STUD AND (1) 2x4 TRIMMER AT EACH END OF (2) PLY HEADER, U.N.O. c.) FOR 2x6 STUD WALL PROVIDE: (1) 2x6 KING STUD AND (1) 2x6 TRIMMER AT EACH END OF (3) PLY HEADER, U.N.O. 7. STUD COLUMNS UNDER BEARING POINTS OF GIRDER TRUSSES OR BEAMS SHALL MATCH PLY COUNT WITH )r TOLERANCE (2-PLY MIN), UNLESS NOTED OTHERWISE. AT MULTIPLE 2x STUDS OR TRIMMERS, USE FACE NAIL 16d G.N. AT 8' O.C. FOR EACH, U.NO. 8. SEE FRAMING PLAN FOR DOUBLE TOP PLATE SPLICE CONDITIONS. A 2X6 MAY BE RIPPED DOWN TO A 2X4 AT POINTS WHERE THE TOP PLATE CHANGES FROM 2X4 TO 2X6 IN LIEU OF ANY CONNECTING STRAP CALLED OUT ON PLAN. 9. ALL BEAMS AND HEADERS, DIMENSIONAL AND ENGINEERED WOOD, SHALL BE A MINIMUM OF (2) PLY UNLESS NOTED OTHERWISE. 10. ALL TOP LOADED BEAMS AND HEADERS SHALL BE NAILED WITH (3) ROWS 16d GUN NAILS OR 12d COMMON NAILS (MIN) AT 12' O.C. UNLESS NOTED OTHERWISED. 11. ENGINEERED LUMBER, SHALL BE I -LEVEL PRODUCTS OR EQUAL TYPE, SIZE PER PLANS. Fb = 3,100 psi MINIMUM. 12. GUN NAILS ARE ALLOWED FOR ALL WOOD -TO -WOOD CONNECTIONS. COMMON NAILS AS SHOWN IN THE ABBREVIATIONS ON THIS PAGE SHALL BE USED FOR METAL -TO -WOOD CONNECTIONS. 13. ALL FASTENING SHALL FOLLOW TABLE R602.3(1) U.N.O. H. PREFABRICATED WOOD TRUSSES: 1. THE ROOF PLAN DEPICTED IS NOT INTENDED TO SERVE AS A TRUSS DESIGN. THESE ARE PRELIMINARY LAYOUT USED ONLY TO DEPICT THE TRUSS CONNECTORS THAT DO NOT MEET THE SPECIFICATIONS OF THE TYPICAL CONNECTOR AS SHOWN IN THE TRUSS LEGEND. LAYOUTS, TRUSS UPLIFTS, TRUSS REACTIONS, PLY COUNTS AND TRUSS -TO -TRUSS CONNECTIONS ARE TO BE PROVIDED BY THE DELEGATED ROOF AND FLOOR SYSTEM ENGINEER. 2. TOP PLATE HEIGHTS MAY VARY. SEE BUILDING SECTIONS, WALL SECTIONS AND ELEVATIONS FOR BEARING HEIGHTS. 3. TRUSS SPACING SHALL BE 24' O.C. MAX. UNLESS OTHERWISE NOTED. CONVENITONAL FRAMING SHALL BE 16" (INCHES) O.C. MAX. OR AS OTHERWISE NOTED. 4. FRAME WALLS UP TO UNDERSIDE OF ROOF TRUSSES AT ALL NON -BEARING WALLS AND AT VOLUME AREA UNLESS OTHERWISE NOTED. 5. ALIGN TRUSSES AND HAND FRAMING SO ALL GYPSUM WALL BOARD WILL BE CONTINUOUS FROM FLOOR TO CEILING. 6. PROVIDE BRACING AND BLOCKING PER SCSI-B3 IN ADDITION TO BRACING AND BLOCKING SHOWN ON TRUSS LAYOUTS PROVIDED BY THE DELEGATED TRUSS SYSTEM ENGINEER. 7. PROVIDE 30 LB. FELT PAPER OR OTHER MOISTURE BARRIER AT ALL CONTACT POINTS BETWEEN TRUSS /NON P.T. WOOD AND MASONRY. A NI PI-1(U? A PF 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. it J SILLS OR PLATES RESTING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED LUMBER. CAST -IN -PLACE BOLTS SHALL BE 1/2' DIA., EMBEDDED 7'. USE 1(f LONG ANCHOR BOLTS AT 2x PLATE UNLESS OTHERWISE NOTED. ANCHOR BOLTS SHALL BE FULL BODY AND HAVE CUT THREADS OR NOMINAL DIAMETER WITH ROLLED THREADS. 3'x3'xO.229' PLATE WASHERS ARE ASTM/ASME B18.22.1. EXPANSION ANCHORS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.2 AND ICC-ES AC193. PRE -APPROVED EXPANSION ANCHORS SHALL BE: SIMPSON STRONG -BOLT TPER FL PRODUCT APPROVAL #15731.1. SCREW ANCHORS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.2 AND ICC-ES AC193. PRE -APPROVED SCREW ANCHORS SHALL BE: SIMPSON WEN HD'PER FL PRODUCT APPROVAL i!15730.7. CAN ONLY SE INSTALLED IN DRY, INTERIOR OR NON -CORROSIVE ENVIROMENTS, NOT FOR EXTERIOR EXPOSED APPLICATIONS. ADHESIVE ANCHORS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.4 AND ICC-ES AC308. PRE -APPROVED ADHESIVE ANCHORS SHALL BE: SIMPSON SET-XP'PER FL PRODUCT APPROVAL #15730.6 OR SIMPSON 'AT-XP'PER FL PRODUCT APPROVAL F6230.1. SIMPSON 'AT-XP' MAY BE SUBSTITUTED FOR SIMPSON SET-XP'. ANCHORS FOR INTERIOR NON -SHEAR WALLS EXPERIENCING ONLY GRAVITY FORCES ARE AS FOLLOWS: a) POWDER -ACTUATED FASTENERS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ICC-ES AC70. PRE -APPROVED POWDER -ACTUATED FASTENERS SHALL BE: SIMPSON POWDER -ACTUATED FASTENERS'PER FL PRODUCT APPROVAL F5730.4. b) SCREW FASTENERS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.2 AND ICC-ES AC193. PRE -APPROVED CONCRETE SCREWS SHALL BE: SIMPSON TTEN SCREWS -PER FL PRODUCT APPOVAL 12355-R4. ADHESIVE ANCHORS IN HOLLOW MASONRY WALLS SHALL MEET THE REQUIREMENTS OF ICC-ES AC58. PRE -APPROVED ADHESIVE ANCHORS SHALL BE: SIMPSON SUPER FL PRODUCT APPROVAL #15730.5. INSTALL ALL POST -INSTALLED ANCHORS IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND CURRENT FLORIDA PRODUCT APPROVAL PRE -APPROVED SUBTITUTIONS FOR 1/2' DIA. CAST -IN -PLACE ANCHOR BOLTS AT INTERIOR WALLS ARE AS FOLLOWS: a) 1/2' DIA. SIMPSON STRONG -BOLT 2'W/ MIN. 2 3/4' EMBEDMENT DEPTH AND CEDGE DISTANCE b) 1/2' DIA. SIMPSON OITEN HD'W/ MIN. 3 1/4' EMBEDMENT DEPTH AND i 3/4-EDGE DISTANCE c) CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING ALL OTHER POST -INSTALLED ANCHORS AS A REPLACEMENT FOR MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. PRE -APPROVED SUBTITUTTONS FOR 1/2' DIA. CAST -IN -PLACE ANCHOR BOLTS AT EXTERIOR WALLS ARE AS FOLLOWS: a) 1/2' DIA. SIMPSON `OTEN HD'W/ MIN. 3 1/4' EMBEDMENT DEPTH AND 1 3/4"EDGE DISTANCE. b) SET-XP EPDXY w/ 4' EMBEDMENT AN 1/2' DIA. F1554 GR. 36 ATR W/ NUT & WASHER. c) CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING ALL OTHER POST -INSTALLED ANCHORS AS A REPLACEMENT FOR MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. PLACE ANCHOR BOLTS AT 4' MIN AND 12' MAX FROM SILL PLATE END OR FROM A NOTCH GREATER THAN 1/2 THE WIDTH OF THE PLATE, A MINIMUM OF 1 3/4" FROM CONCRETE EDGE, AND SPACED AT 24' O.C. MAX SILL PLATES SHALL BE TREATED WITH DISODIUM OCTABORATE TETRAHYDRATE (DOT) (NER 648) OR ANOTHER LOW CORROSIVE CHEMICAL TREATMENT. DO NOT NOTCH OR BORE LARGE HOLE AT JOISTS, RAFTERS, BEAMS OR PLATES, UNLESS NOTED OTHERWISE. OBTAIN APPROVAL FROM ENGINEER FOR NOTCHES AND HOLES NOT DETAILED. BOLT HOLES SHALL BE 1/16' MAXIMUM LARGER THAN THE BOLT SIZE. USE STANDARD CUT WASHERS UNDER BOLT HEADS OR NUTS AGAINST WOOD. CONNECTION HARDWARE SHALL BE SIMPSON STRONG -TIE. WOOD STRUCTURAL SHEATHING: SEE STRUCTURAL DETAILS FOR SIZES AND TYPES OF SHEATHING. K. FIELD REPAIR NOTES: 1. MISPLACED DOWEL NOTE: THIS NOTE IS TO DESCRIBE ALTERNATIVES TO MITIGATE FOR CASTING #5 REBAR VERTICAL REINFORCING AT AN INCORRECT LOCATION. IF THE WALL HAS NOT BEEN BUILT. DRILL A Y4" DIA. HOLE 6' DEEP INTO THE THICKENED EDGE OF THE SLAB AT THE CORRECT LOCATION. EPDXY A 36' LONG #5 REBAR WITH SIMPSON TYPE 'SET' EPDXY INTO THE DRILLED HOLE. FOLLOW THE MANUFACTURER'S REQUIREMENTS REGARDING CLEANING THE HOLE AND MIXING THE EPDXY. AS THE WALL IS BUILT LAP REBAR PER REINFORCING STEEL SCHEDULE (IN GENERAL NOTES) AND BEND VERTICAL BAR 90 DECREES TO ACHIEVE A 12' LONG LAP WITH THE CONTINUOUS REBAR IN THE TIE BEAM. IF THE WALL HAS BEEN BUILT, PRIOR TO LINTEL POUR, OPEN THE WALL AT THE CORRECT LOCATION APPROX. 16' HIGH AND 4' WIDE AT THE FLOOR. DRILL HOLE AND INSTALL A 32' LONG REBAR AS DESCRIBED ABOVE. LAP VERTICAL STEEL AS DESCRIBED ABOVE INTO TIE OR BOND BEAM. FORM WALL AND POUR DOWNPOUR SOLID NTH GROUT AS SPECIFIED. 2. MISSING OR MISPLACED ANCHOR BOLT (ALTERNATE BOLTING FOR WOOD SOLE PLATES). THIS NOTE IS TO DESCRIBE ALTERNATES TO ANCHOR BOLTS IN THE SLAB AND BOND BEAM BUT DOES NOT APPLY AT STEP DOWN AND/OR CURB CONDITIONS. 2.1 IF THE BOLT TO BE INSTALLED IN THE SLAB MEETS THE MINIMUM CONCRETE EDGE DISTANCE AS SPECIFIED BY THE MANUFACTURER, OR IS AT LEAST 2-r FROM ANY EDGE FOR V BOLTS AND 3-)f FDIC V AND N47 BOLTS, THEN A STANDARD EXPANSION BOLT EMBEDDED 5' MINIMUM AND THE SAME DIA. AS THE SPECIFIED ANCHOR BOLT MAY BE USED (SPACING FOR BOLTS AT WOOD SOLE PLATES SHALL BE REDUCED FROM 24' TO 16'). 2.2 IF THE BOLT TO BE INSTALLED IN THE SLAB DOES NOT MEET THE MINIMUM CONCRETE EDGE DISTANCE AS SPECIFIED ABOVE OR IS TO REPLACE BOLTS SPECIFIED IN BOND BEAMS, THEN INSTALL AN TITEN HD AT THE SAME SPACING AS SPECIFIED ON THE PLANS. TITEN HD SHALL BE A MINIMUM )f x 6", OR AS REQUIRED ON THE DRAWINGS. ALTERNATE CONNECTION IS AN ANCHOR W/SIMPSON TYPE "SET' EPDXY THE SAME SIZE AS THE ONE BEING REPLACE W/ A 6' MINIMUM EMBEDMENT SLEEVE ANCHORS ARE NOT ALLOWED. 3. MISSING OR MISPLACED TRUSS STRAP ANCHOR SEE THE DETAIL IN THESE DRAWINGS. FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/8' BUT LESS THAN 1 1/2' FROM THE FACE OF THE TRUSS, A SHIM MUST BE PROVIDED AND NAILS SHALL BE INCREASED TO GO THROUGH BOTH PLYS OF MATERIAL (I.E. 3' NAILS). WHEN GAP IS GREATER THAN 1 1/2', INSTALL NEW ANCHORS. 4. CMU OVERHANGING SLAB 4.1 FOR BLOCK OVERHANGING THE SLAB BY )f OR LESS, NO REPAIR IS NECESSARY. 4.2 FOR BLOCK OVERHANGING THE SLAB BETWEEN V AND 1 V, GROUT THE BOTTOM 3 COURSES OF IN AFFECTED AREA OF WALL 4.3 FOR BLOCK OVERHANGING THE SLAB BY MORE THAN 1)r, CONTACT THE E.O.R. FOR REPAIR. 5. NOTCHED STUDS IN WALLS STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH GREATER THAN 25% OF THE WIDTH IN BEARING WALLS, OR 40% IN NON -LOAD BEARING WALLS; OR WHEN A HOLE IS DRILLED/BORED TO A DIAMETER EXCEEDING 40% OF THE STUD WIDTH IN BEARING WALLS (1-3/8-FOR A 2X4 STUD OR 2-3/16-FOR A 2X6 STUD), OR 60% OF THE STUD WIDTH IN NON -BEARING WALLS (2-1/8-FOR A 2X4 STUD OR 3-5/16'FOR A 2X6 STUD). IF THE MAXIMUM HOLE/NOTCH SPECIFICATIONS ARE EXCEEDED THEN A STUD SHOE MUST BE INSTALLED. STUD SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE HSS2-SDS1.5 WITH (12)-1/471-1/2' SDS SCREWS. FOR MULTI -PLY 2X STUDS USE HSS2-61'--SDS3 WITH (12)-1/4N3'SDS SCREWS, WHERE '#'CORRESPONDS TO THE NUMBER OF STUDS IN THE MULTI -PLY. 6. NOTCHED TOP/BOTTOM PLATES a. FOR PLUMBING/MECHANICAL UTILITIES A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 50% OF THE PLATE WIDTH IS REMOVED FOR PIPING (EXCEPT WHEN THE SIDE OF THE WALL WITH THE NOTCH OR CUT IS COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT THROUGH. THE REQUIRED REPAIR IS A GALVANIZED 16-GAUGE METAL TIE THAT IS AT LEAST 1-1/2-WIDE AND MUST BE FASTENED WITH (8)-16D NAILS ON EACH SIDE OF THE OPENING (EX. RPS). PROTECTION OF PIPING WITHIN THE WALL IS REQUIRED WHEN PIPING OTHER THAN CAST IRON OR GALVANIZED STEEL (I.E. PVC OR ABS) IS CLOSER THAN 1-1/2'TO THE EDGE OF THE PLATE, OR PLASTIC AND COPPER PIPING IS CLOSER THAN 1'FROM THE EDGE OF THE PLATE. THE REQUIRED REPAIR IS A GALVANIZED 16-GAUGE STEEL PROTECTIVE PLATE THAT COVERS THE SIDE OF THE PLATE AND EXTENDS TABOVE/BELOW IT (OR AS AN APPROVED ALTERNATE, A STEEL PROTECTIVE PLATE NOT LESS THAN 18 GAUGE THAT EXTENDS 1-1/2'BEYOND THE PIPE ON EACH SIDE). b. FOR HVAC UTILITIES REPAIR IS THE SAME AS MENTIONED ABOVE FOR PLUMBING/MECHANICAL UTILIES EXCEPT WHEN THE ENTIRE PLATE IS REMOVED FOR DUCTWORK A 16-GAUGE METAL TIE SHOULD BE INSTALLED ON BOTH SIDES OF THE CUT PLATE. WHERE THE TOP PLATE HAS BEEN REMOVED FROM TWO (2) CONSECUTIVE BAYS, A 3' WIDE STRAP THAT SPANS BOTH BAYS IS REQUIRED (EX. MSTC52) L. JURISDICTION SPECIFIC INFORMATION: 1. FOR ALL PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO, LANAIS, PORCHES AND BALCONIES, %' MINIMUM EXTERIOR GRADE SOFFIT BOARD WITH A CEMENRTIOUS KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE REQUIREMENTS OF ASTM C932 TO GIVE THE CEILING WATER RESISTANCE. THE SOFFIT BOARD PRODUCT WOULD NEED TO BE ATTACHED PER MANUFACTURER SPECIFICATIONS. THIS APPLICATION WOULD BE IN COMPLIANCE WITH R703.1. 2. THE SOFFIT DESIGN PRESSURE IS AS NOTED IN THESE DOCUMENTS. IN SO LONG AS THE KAYCAN VINYL SOFFIT IS INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTALLATION REQUIREMENTS AND ICC-ES EVALUATION REPORT ESR-1495 THE SOFFIT WILL COMPLY WITH R703.1 Roof Pressures Wall Pressures Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 14.8 -23.6 14.8 1 -41.0 14.8 1 -60.6 25.8 -27.9 25.8 -34.4 DESIGN PRESSURE CALICS Description Zone Width (ft) Height (ft) Effective Area (ft2) Positive Pressure Negative Pressure (psf) 16070 OHGD --- 16 7 112 21.9 -24.4 3080 DOOR 4 3 8 24.0 24.4 -26.6 6080 SGD 5 6 8 48.0 23.2 -29.2 4010 FIXED 4 4 1 1 4.0 25.8 -27.9 25SH 4 3 5.25 15.8 25.1 -27.2 24SH 4 4 4.166667 16.7 25.0 -27.1 25SH (2) END 5 6 5.25 31.5 24.0 -30.9 25SH END 5 3 5.25 15.8 25.1 -33.1 (2) 26SH END 5 6 6 36.0 23.8 -30.5 25SH (3) 4 9 5.25 47.3 23.2 -25.4 DESIGN PRESSURES SHOWN ARE MINIMUM ALLOWABLE VALUES. VALUES ARE TO BE INCREASED AS REQUIRED BY MORE STRINGENT LOCAL REQUIREMENTS ABBREVIATIONS: A. PLYWD = PLYWOOD B. OSB = ORIENTED STRAND BOARD C. NAILING: C.A. 8d = COMMON NAIL C.B. 10d = COMMON NAIL C.C. 12d = COMMON NAIL C.D. 16d = 0.135' x 3 1/2' GUN NAIL C.E. EN = EDGE NAILING C.F. FN = FIELD NAIUNG C.G. SN = SIDE NAIUNG C.H. BN = BOUNDARY NAIUNG C.I. BF = BOUNDARY FASTENING D. AB = ANCHOR BOLT E. CMU= CONCRETE MASONRY UNIT F. CONC = CONCRETE G. DIA = DIAMETER H. DTL = DETAIL I. AND = FOUNDATION J. MAX = MAXIMUM K. MIN = MINIMUM L O.C. = ON CENTER M. SP = SOUTHERN PINE N. SPF = SPRUCE PINE FIR 0. TYP = TYPICAL P. U.N.O. = UNLESS NOTED OTHERWISE Q. I.L.O. = IN LIEU OF R. w/ =WITH S. WD = WOOD T. EE = EACH END U. HDR = HEADER V. J = OPENING JACK STUD W. K = OPENING KING STUD X. SIM = SIMILAR Y. ATR = ALL THREADED ROD Z. S.C. = SAW CUTS AA. C.J. = CONTRACTION JOINT AB. DEN = DOUBLE EDGE NAIUNG AC. COL = COLUMN AD. REIN = REINFORCEMENT AE. PLT = PLATE AF. CANT. = CANTILEVER AG. SC = BUILT-UP STUD COLUMN AH. MANUF. = MANUFACTURER C.O.A.# ARCHITECTURE: AA26002802 C.O.A.# ENGINEERING: 29349 CI THOMAS A. WEBER, PE P.E. # 73242 FLORIDA ■ BENJAMIN NIESE, PE P.E. # 86025 FLORIDA 10/14/20 DATE No. OF AL Till a CD M0M 4� o0 c� O 00 A� U ILI r" # N � *PulteGroup- PRODUCT MANAGER RELEASE DATE: xx/xx/xxxx PROJECT TYPE A 1 T SPECIFICATION LEVEL I Pt lte PLAN NAME Highgate NPC CHn NU ER 2811.500 SHEET SO.1 (1) #5 REBAR w/ 25' LAP U.N.O. CMU COL PER 8" C.M.U. FINISH PER ELEV. PLAN OIL -0'-0" FINISH GRADE 00 MONOLITHIC FOUND. W/ (2) #4 DIA. RODS CONT. ON CHAIRS 9' STARTER 1'-0" COURSE 1-4' 0 2 ST Y ALT. CMU SEAT 0 -1V =01 EXTERIOR MASONRY WALL FTG FROM TOP of SLAB SCALE 1/2'=1'-0 3/4" RECESS IN SLAB 10 1/2" 8" C.M.U. WALL FINISH PER ELEVATION FINISH FLOOR " SLOPE MONOLITHIC FOUND. w/(2) #4 DIA. RODS CONT. ON CHAIRS. GARAGE DOOR RECESSED SILL PAVERS OR SLAB PER SLOPE SPEC. —` CONCRETE FOOTING PER PLAN MASONRY WALL SCALE: 1/2'=1'-0 3/4' RECESS IN SLAB — FINISH FLOOR PER PLAN of �ff JER ON SPREAD FTG. CMU COL PER PLAN —#5 REBAR cn w/25" MIN LAP LAJ ar- -c-o" SLOPE ¢ z m chi CONCRETE FOOTING ::::P. "' ER PLAN o .; .-Zr PER PLAN tens) MASONRY WALL CORNER ON SPREAD FTG. 8' C.M.U. WALL FINISH PER ELEVATION SLOPE ` MONOLITHIC FOUND. �:�• w/(2) #4 DIA. RODS CONT. ON CHAIRS. V-4' 0 2 STORY SCALE: 1/2'=1'-0 RECESS WITH PAVERS RECESS WITH SLAB 2x AT 24"O.C. MAX. 2x P.T. PATE SECURED TO SLAB w/ 3' POMOER ACTUATED FASTENERS OR TAPCONS 016' O.C. OR (2) ROW512a 1/2' G.W.B. EA SIDE Gut NAILS 012" O.C. 2x P.T. PLATE SECURED TO SLAB w/ STEP PER PLAN 3' POW ACTUATED FASTENERS OR T OR (2) ROW512d SLOPE GUN 2 MIS 01O. START SLOPE HERE 2" � Lim SLOPE " — 1'—0" 6 1�2" (1) #4 ROD CONT. ON CHAIRS LINO STEP C_ ONDIDIT ON FLUSH N SCALE: 1 /2"=1'-0 8' C.M.U. FINISH PER ELEV. FINISH FLOOR FINISH GRADE PENETRATING PIPE MONOLITHIC FOUND. w/(2) #4 DIA. RODS COLT. ON CHAIRS PVC SLEEVE 1'-4' 0 2 STORY BEARING PENETMN DETAIL (SIDE VIE SCALE: 1/2'=1'-O PENETRATING SCALE: 1/2'4-0 #5 REBAR w/25" MIN LAP Paz m CCD o z SCALE: 1/2'=1'-0 2-1/2' 0 IMPACT (1) #5 REBAR AT EACH - FILLED CELL CMU STRUCK BOTH WAYS POURED CURB FINISH GRADE �i —MONOLITHIC FOUND. w/(2) #4 DIA. RODS tl. '_D• L CUNT. ON CHAIRS 1'-4' 0 2 STORY2 STORY EXT. MASONRY WALL @ GARAGE SCALE: 1/2'=1'-0 GROUT BED D PAVERS PER SPEC DOOR PER SPEC PAVERS PER (THICKNESS VARIES) DOOR THRESHOLD a ct: SPEC (THICKNESS SLOPE OILJi a VARIES) 7/ SLOPE ,. PER PLAN ,. �. 0o � � FL oMONOLITHIC FOUND. MONOLITHIC FOUND. 1'-4" 0�2-STORY w/(2) #4 DIA. RODS w/(2) #4 DIA. RODS CONT. ON CHAIRS . . 1-4 0 2-STORY CUNT. ON CHAIRS EXTERIOR DOOR SILL @SGD (Pavers) EXTERIOR DOOR SILL @ ENTRY (Pavers) SCALE 1/2'=1'-0 SCALE: 1/2'=1'-0 (1) #4 ROD CONT. ON 2x AT 24'O.C. MAX CHAIRS TYPICAL 3 1/2' CONC. FINISH GRADE SLOPE SLAB 1/2' G.W.B. EA. SIDE .;I —4 8' C.M.U. FINISH PER ELEV. FINISH FLOOR LOOP TIE (TYP.) MONOLITHIC FOUND. W/ (2) #4 DIA. RODS CONT. ON CHAIRS THICKENED SLAB EDGE SCALE: 1/2'=1'-0 (1) /4 REINFORCMENT 4" SEE FOUNDATION PLAN 4" BAR CONT. a a CONC. PER SCHEDULE w a SLOPE TO DRAIN SHOWER RECESS SCALE 1/2'=1'-0 PAVERS TYP. '•�+-r-•+� \ � (1) #4 BAR CUNT. \\� COMPACTED FILL PAVER AT CONCRETE GRADE BEAM '.I oL PER PLAN 'i:', " MONOLITHIC FOUND. W/ (2) 14 DIA. RODS CONT. ON CHAIRS 17-4' j'-Q" 0 2 STOTY ALT. BRICK THRESHOLD 12' SQUARE C.M.. ' COL PER PLAN w (2) #5 REBAR w/ 25" LAP MIN. 0 EACH FILLED CELL OIL -0' SLOPE PAVERS OR SLAB PER SPEC. CONC. FOOTING PER PLAN PER PLAN Foso MASONRY COL. ON SPREAD FTG. SCALE: 1/2'=1'-0 DOOR PER SPEC DOOR THRESHOLD,PER PLAN co i ALT. FLUSH BRICK THRESHOLD EXTERIOR C SCALE 1/2'=1'-0 VERTICAL DOWEL - AS REO'D IN PLAN LAP SPLICE REINF. PLACEMENT AT FTG. CORNERS SCALE: 1/2"=1'-0 CORNER BAR WITH 25' MIN. LAP SPLICE EACH SIDE SAME SIZE AS CONT. FOOLING STEEL NUMBER OF CORNER BARS EQUALS NUMBER OF CONT. BARS NUMBER OF REBAR PER PLAN C.O.A.# ARCHITECTURE: AA260028M C.OA.# ENGINEERING: M49 ❑ THOMAS A. WEBER, PE a P.E. # 73242 FLORIDA N ■ BENJAMIN NIESE, PE P.E. # 86025 FLORIDA 10/14/20 0 DATE [V s ALO RIO CL CD CV O CV U 95 U c cn M OO O 00 AOLP .N N Poo V� o •_ o bb cn N a *PulteGroup- V T a N Irs Ni C go 0 H O N E-1 � Q a o0 o Q -1c Z w 00 w PRODUCT MANAGER RELEASE PROJECT TYPE Single Famil SPECIFICATION LEVEL PWte 1PLAN NAME Highgate NPC CHIM NU ER 2811.500 SHEET S1.0 3 d \ v O CV O N 0 0 FOUNDATION PLAN SCALE: 1/4"=1'-O" 0 I a 3'-1 1 /2" 7'-0" VERIFY M.O. 40'-0" 30'-0" 10'-0" 4'-51/2' 8" 10'-2" 8" 2'-7" 91-0" 24"x24"x12" CONC. FTG. w/ VERIFY M.O. #4 BARS 6" O.C. EA WAY / F03C S1.0 �l_ w/ OPT. SCREEN • ... F01 s1.o F01 _ s1.o - • W ENCLOSURE o F11 s1.o --- o ( ~ 1'-21/2" � 6'-8" 2'-11/2" = N I = N tI) CV VERIFY M.O. I CJ • • • • --- o -� •I 0 CJ • 9" 3'-01/2' F07 I o o I T I ( F26 CJ • `Y S1.0 o �M I ICD I. I • I o -- 0 o O • CJ CJ I • cj 0 00 � REFER TO ARCHITECTURE FOR f08 I • ACTUAL WALL LOCATION S1.0 I — SLOPE STARTS -I CJ co HERE II I I CID • 20'-1 " I • I VARIES _ o CJ I F07 S1.0 I I _ I � CJ F04PVERIFY S1.0 5 N M.O. M " "I 2 3 -4 5 1 ■ I CJ F01 I • I S1.0 d- F01 gaLL - • d' J _ - • I •• •• • • •• •• • VERIFY M.O. IV VERIFY M.O. 11-9" 8" 16'-8" 8" 1'-g" 2'-111/2" 8" 7'-0" 8" 2'-111/2" 21'-6" 4'-3" 14'-3" 40'-0" LEGEND SYMBOLS Q 8x8 FILLED CELL W/ 15 REBAR • 2 8x8 FILLED CELL W/ (2)#5 REBAR 0 INSIDE FACE DO 8x8 FILLED CELL W/ NO REBAR REQUIRED Ful 45' CMU - FILL CELLS W/ #5 REBAR Ik 1202 FILLED CELL W/ (4)-#5 REBAR E-LEV ELEVATION INDICATOR - ELEVATION NOTED IS YY RELATIVE TO FINISH FLOOR DATUM = 0'-0' XX DETAL INDICATOR FLOOR SLAB NOTES: 3 1/2' 2,500 PSI CONCRETE SLAB ON 6MIL VAPOR BARRIER LAPPED 6' AND TAPED OVER CLEAN COMPACTED SOIL SLAB REINFORCEMENT FLOOR SLABS SHALL BE REINFORCED BY STEEL REINFORCING BARS AT REENTRANT CORNERS SUCH AS INSIDE CORNERS OF AN 'L' SHAPED SLAB. REENTRANT CORNERS SHALL HAVE TWO PIECES OF REBAR, 36' (914mm) LONG, PLACED DIAGONALLY TO THE CORNER, 12' (305mm) APART, WITH THE FIRST BAR PLACED 2' (51mm) FROM THE CORNER. ALL. REINFORCEMENT SHALL BE SUPPORTED TO REMAIN IN PLACE FROM THE CENTER TO THE UPPER 1/3 OF THE SLAB FOR THE DURATION OF THE CONCRETE PLACEMENT. PLUMBING NOTES: REFER TO ARCHITECTURAL PLUMBING FIXTURE PLANS FOR ALL FIXTURE LOCATIONS C.O,A.# ARCHITECTURE: AA260028M C.O.A.# ENGINEERING: 29349 0 THOMAS A. WEBER, PE P.E. # 73242 FLORIDA ■ BENJAMIN NIESE, PE P.E. # 86025 FLORIDA 10/14/20 DATE o. 5 1 ` E O R/Do;.'' �r�~ Z5 0 N N S2 0 U El o� l'/ 41 00 M 0 U.) � O 00 A� v U N 0 1*PulteGroup- PRODUCT MANAGER RELEASE DATE: XX /XX /XXXX PROECT TYPE Sinele Family SPECIFICATION LEVEL Pt lte PLAN NAME Hi h ate NPC CHU NU ER 2811.500 SHEET SIM WALL BASE PLAN SCALE: 1 /4"=l'-0" LINTEL AND BOND BEAM LEGEND 1. BOND BEAM IS TO BE 8" KNOCK OUT BLOCK PATH /5 BAR GROUTED SOLID, CONTINUOUS AROUND PERIMETER OF STRUCTURE. 2. MINIMUM 4" NOMINAL BEARING PER END 0 LINTELS OR AS REQUIRED BY MANUF. 3. LINTELS WITH A CLEAR SPAN LONGER THAN 12'-4" SHALL BE PRESTRESSED. 4. BOND BEAM ELEV = 9'-4' U.N.O. 5. GARAGE DOOR LINTEL HEIGHT MAY HAVE A TOLERANCE OF +/- 4' FOR All LINTELS 28" OR GREATER. TYPE DESIGNATION F = FILLED WITH GROUT U = UNFILLED OF REBAR AT FQUANTITY BOTTOM OF LINTEL CAVITY 6— 11 B/1 T LL-QUANTITY OF #5 REBAR AT TOP r NWIN AL HEIGHT NOMINAL WIDTH #5 REBAR AT TOP MIN. (1) REVO 1-1/2' CLEAR a CMU 0o z � 3 GROUT 1 - #5 REBAR AT BOTTOM OF LINTEL CAVITY 7-5/0BOTTOM REINFORCING ACTUAL PROVIDED IN LINTEL (VARIES) 8' NOMINAL WIDTH LEGEND DETAIL INDICATOR ® LINTEL OR WOOD HEADER DESIGNATION ALL WOOD HEADERS TO BE (2) PLY U.N.O. HEADER SCHEDULE U.N.O. OPENING SIZE HEADER REMARKS LIP TO 3'-4" DOUBLE 2x6 ------- S-5' - 6'-0' DOUBLE 2x8 ------- 6'-1' - 8'-6' D(X1BLE 2x10 2 JACK STUDS, EACH END. 8'-r - 12'-6' DOUBLE 202 2 JACK( STUDS, EACH END. #5 REBAR IN VERTICAL GROUT FILLED CELL ROUGH OPENING BELOW p PRECAST LINTELS FILLED WITH GROUT L3 MITER LINTELS /// BY FIELD CUTTING #5 CORNER DOWELS INSIDE AND ❑UTSIDE OF VERTICAL #5 BAR AS SHOWN 90 CORNER DETAIL w/ COLUMN BELOW KM C.O.A.# ARCHITECTURE: AA26002802 o� c� 410 00 O VJ � O O A� M U CJ� co c� 4-A N as llkPulteGroup- PRODUCT MANAGER IRELEASE I IIATC• vv /vv /vvvv C.O.A.# ENGINEERING: PROJECT TYPE im 29349 Single Famfl 0 THOMAS A. WEBER, PE P.E. # 73242 FLORIDA ■ BENJAMIN NIESE, PE SPECIFICATION LEVEL P.E.#686025 FLORIDA �U�lj p„jte 10/14/20 � DATE,,', ♦♦♦���pM! ��� PLAN NAME ♦��. s'- Hi h ate NPC CHn NU ER ` No. z 12811.500 STAT �A ' SHEET /IIOG ♦ ~ S2.1 '�'�NAL. �� 3 d 0 cV CN v 0 U U 0 CV CV N 0 ROOF FRAMING PLAN SCALE: 1 /4"=1'-O" GENERAL NOTES 1. REFER TO ARCHITECTURAL DRAWINGS FOR WALL HEIGHTS. 2 REFER TO STRUCTURAL DETAILS FOR STEPPED MASONRY WALL HEIGHT DETAIL 3. ALL INTERIOR CEILING SHEATHING TO BE GYPSUM. 4. ALL EXTERIOR SHEATHING TO BE MINIMUM 7/16 " APA RATED SHEATHING. 5. FLOOR SHEATHING (IF APPLICABLE) SHALL BE 2" MIN. 6. REFER TO DETAILS FOR ROOF SHEATHING RECUfREMENTS. 7. U.N.O. INTERIOR SHEATHING TO BE GYPSUM AS REQUIRED IN ARCHITECTURAL DRAWINGS. 8. PROMDE SOLID BLOCKING FROM ALL BEAMS & GIRDERS TO FOUNDATION BELOW. TRUSS NOTES UNLESS OTHERWISE NOTED ON PLANS: 1. ALL TRUSS STRAPS TO MASONRY ARE TO BE META16. 2 ALL TRUSS TO FRAME SCREWS ARE TO BE THE FOLLOWING: A) TRUSS TO TOP PLATE TO BE (2) SIMPSON SDWC15600. B) MULTI -PLY TRUSS REQUIRE (2) SDWC15600 AT EA PLY. C) (1) SDK15600 MAY BE USED ON JACK TRUSSES. 3. THESE PLANS ARE ENGINEERED BASED ON TRUSS LAYOUTS AND ENGINEERING PROVIDED BY THE DELEGATED TRUSS ENGINEER. CHANGES OR MODIFICATIONS ARE NOT PERMITTED WITHOUT A LETTER FROM THE ENGINEER OF RECORD. LEGEND LTR DETAIL INDICATOR SHT CROSS HATCHED AREA INDICATES EXTENT OF GABLE END BRACING TRUSS LAYOUT SHOWN ON THIS SHEET IS FOR EXAMPLE PURPOSES ONLY TO ILLUSTRATE TRUSS TO WALL CONNECTIONS. THIS LAYOUT HAS BEEN PROVIDED BY A THIRD PARTY FOR EXAMPLE PURPOSES ONLY; THE ACTUAL TRUSS MANUFACTURER LAYOUTS ARE TO BE USED FOR ALL STRAP LOCATIONS. PER BUILDING CODE STATUTES, THE ROOF AND/OR FLOOR SYSTEM HAS BEEN DELEGATED TO THE TRUSS MANUFACTURER'S PROFESSIONAL ENGINEER. C.O.A.# ARCHITECTURE: AA26002802 C.OJL# ENGINEERING: 29349 O THOMAS A. WEBER, PE P.E. # 73242 FLORIDA ■ BENJAMIN NIESE, PE P.E. # 86025 FLORIDA 10/14/20 DATE %J1111111,, 40� 5 a CD O N x c� 95 cl- U C M 44 DD V� � O O ACN v � v� U �as N 0 lkPultoGroup- 0 T V a N 4 W � v .01 a a 0 o� cf) v Z 6-4 v f� O vz% w 0 0 T PRODUCT MANAGER RELEASE DATE: XX/XX/XXXx PROICT TYPE I Sinele Family SPECIFICATION LEVEL I Pulte PLAN NAME Highgate NPC CHfM NU ER 2811.500 ma SHEET S3.1 O o �— z x 2x BLOCKING AT o SHEATHING EDGES t NOTE STRUCTURAL SHEATHING CONTINUOUS REFER TO ARCHITECTURAL AT TRUSS HEEL, w/ SHEATHING EDGE DRAWINGS AND/ OR TRUSS NAILING REQUIRED. MANUFACTURER DRAWINGS FOR FRAMING PER PLAN CONTINUOUS STRUCTURAL SHEATHING SPECIFIC TRUSS PROFILE INFORMATION. (i.e. HEEL WHEN 9-1 4' < "D' < 15-1 4': / HEIGHTS, SLOPE, OVERHANGS). SOLID 2x BLOCKING BETWEEN TRUSS ANCHOR PER PLAN TRUSSES ATTACHED TO TOP 5 PLATES w/ 8d NAILS 0 6 O.C. STRUCTURAL SHEATHING ALONG LENGTH OF BRACED N' SEE PLAN AND DETAILS FOR DETAIL AT RAISED HEEL WALL PANELS . ATTACHMENT o PRE-ENGINEERED WOOD TRUSSES AT 2'-0' O.C. MAX. TRUSS ANCHOR PER PLAN FASCIA SEE ARCH. DRAWINGS BOND BEAM PER PLAN R01 I'OOF TRUSS ON MASONRY STRUCTURAL SHEATHING PER PLAN 2x4 LADDER FRAMING AT 24' O.C. REQ'D AT OVERHANGS GREATER THAN 12'. ATTACH TO TRUSS TOP CHORD w/ (2)-16d NAILS AT 24" O.C. CONT. 2x4 w/ (2) 12d NAILS 1. AT VERTICALS 3'-6" TO 6'-6' USE ONE 2x4 °L° BACK.--N, 2. AT VERTICALS OVER 6'-6' TO 8'-4' USE (2) 2x4 BACKS (1 EA. SIDE) (OR FRAME PER CASE 3 BELOW). 3. AT VERTICALS OVER 8'-4' TO 13'-0' USE ONE 2x4 :: O 'L' BACK AND AN ADDITIONAL DIAGONAL BRACE IS REQUIRED AT THE PEAK AND AT EVERY OTHER VERTICAL MEMBER IN THIS RANGE. ATTACH THE DIAGONAL AT MID HEIGHT AND TO THE BLOCKING BELOW THE ROOF SHEATHING w/ (5) 12d's AT EACH END. IN ADDITION TO THE SECOND DIAGONAL, A STRONGBACK IS ALSO REQUIRED AT THESE VERTICALS AND MUST BE ATTACHED TO EACH 'L' BACK WITH (2) 12d's AND ONE SIMPSON H5 CONNECTOR. PER PLAN 2x BLOCKING BETWEEN TRUSSES w/ (3) 8d INTO SUPPORT 0 EA END TO ADJACENT TRUSS OR TO TOP PLATES SHEATHING PER PLAN � '^ I TRUSS SCREW THRU �A110N OF BRACING AT "' � TOP PLATES TO TRUSS VAULTED TRUSS. DETAIL AT RAISED HE TRUSS SCREW O 0 NOTE: PER PLAN CONTINUOUS BRACING TRUSS MANUF. 'vz REFER TO ARCHITECTURAL DRAWINGS AND/ OR TRUSS MANUFACTURER SHEATHING PER PLAN DRAWINGS FOR SPECIFIC TRUSS PROFILE STUD PER PLAN INFORMATION. (i.e. HEEL HEIGHTS, SLOPE, OVERHANGS). FRAMING PER PLAN Q TRUSS SCREW THRU TOP PLATES TO TRUSS Q TRUSS ANCHOR ATTACHED TO TOP PLATES ON EXT. SIDE OF WALL R02 ROOF TRUSS ON FRAME 2x4 BLOCKING AT DIAGONALS ONLY. ATTACH AT EACH END w/ (2) 12d TOENAILS. NAIL SHEATHING TO BLOCKING AT 6' O.C. w/ MINIMUM 8d NAILS. BLOCK 4 BAYS BACK STRUCTURAL SHEATHING PER PLAN FROM GABLE TRUSS. 20 LADDER FRAMING AT 24' O.C. REQ'D AT WHEN SECOND BRACE IS REQUIRED, NAIL TO OPPOSITE OVERHANGS GREATER THAN 12'. ATTACH TO TRUSS SIDE OF BLOCKING. TOP CHORD w/ (2)-16d NAILS AT 24" O.C. 2x6 DIAGONAL BRACING w/ (5) 10d COMMON NAILS TO BLOCKING. UNLESS NOTED OTHERWISE ON PLANS, PROVIDE ONE BRACE NEAR THE PEAK AND THE REMAINDER AT 48" O.C. 0 APPROX. 45-DEG ANGLE. SPLICE DETAIL FOR DIAGONAL 4' LAP WITH 'T" LAP NAILED w/ (2) ROWS 10d GUN NAILS 0 8' O.C. (2) SIMPSON A23 w/ (8) 10d x 1-1/2' (ONE ON EACH SIDE OF BRACE TO TOP PLATE). SIDE NAIL ALL "L' BACKS AND STRONGBACKS w/ 12d's SHEATHING PER PLAN AT 6' O.C. NOTCH 'L" BACKS AT TOP AND BOTTOM. PROVIDE CONT. 2x8 P.T. PLATE w/ 1/2' 0 x 10" ANCHOR BOLTS AT 4'-0' O.C. MAX. w/2'x2" PL STRUCTURAL SHEATHING CMU SEE PLAN FOR ATTACHMENT WASHERS AND 7" EMBEDMENT. NAIL BOTTOM CHORD OF GABLE MASONRY WALL, BOND BEAM, LINTEL BEAM OR RAKED 12d's AT 4' O.C. BEAM PER PLAN. FOR RAKED BEAM AT VAULTED TRUSS w/ CONDITION, SEE PLAN AND DETAIL / CONT. 2x4 20 NAILED FLAT TO TOP OF BRACE ('T° 2x6 NAILED CONTINUOUS / \ BRAG) NAILED TO DIAG. w/ 1Od GUN 0 TOP STRUCTURAL NAILS 0 8' O.C. BUTT JOINT ALLOWED SHEATHING SEE PLAN (48' MIN MEMBER LENGTH), BRACED FOR ATTACHMENT REQUIRED TO BE CONTINUOUS OVER DIAG. FIELD NAILING / BRACE SPLICE SHOWN \ PER PLAN 2 4 BLOCKING AT 48" 0 C \ 3xTRUSS BAYS 2x6 NAILED 0 BOTTOM FRAMING WOOD PER PLAN GABLE END DIAGONAL BRACE TYPICAL SPLICE R09 "GABLE EiUTRUS�SB RACING DE�tl GABL (8) 10d NAILS EACH ' ENGINEERED WOOD ROOF TRUSS AT 24" O.C. MAX. CMU WALL (4) 1/4' 0 c 2-1/4" MASONRY SCREWS AT EACH STRAP. (1) SIMPSON HTSM16 COND110NS OF USE: (OR APPROVED EQUAL) 1. QUANTITY OF MISSED STRAPS DOES NOT EXCEED FIVE (5) CONSECUTIVE LOCATIONS. AT EACH MISSED 2. UPLIFT VALUE FOR TRUSS LOCATION DOES NOT EXCEED 1,175 lbs. UPLIFT. LOCATION. 3. NOT ACCEPTABLE ON MULTI -PLY TRUSS APPLICATIONS. IF FIELD CONDITIONS EXCEED CONDITIONS OF USE, CONTACT ENGINEER OR ARCHITECT OF RECORD FOR APPROPRIATE SOLUTION. ('1313 MISSED TRUSS STRAP REPAIR (TYPICAL CMU WALL CONNECTION) CONT. 20 w/ (2) 12d NAILS STRUCTURAL SHEATHING PRE-ENGINEERED WOOD 2x4 OUTLOOKER PER DRAWINGS 2x6 FASCIA 1 x6 wA3) 8d 0 EA. OUTLOOKER VALLEY SET TRUSSES \ AT 24" O.C. ROOF SHEATHING PER PLAN MIN. 9' LONG 20 GA. FLAT STRAP w/ (8) 10d SHEATHING PER —OR- PLAN. 20 BLOCKING UNDER TRUSS ENDS. NAIL TO TRUSS CHORDS w/ (3) 10d EACH END. Qua VALLEY SET OVER FRAME I Ivv ►M 20 BLOCKING AT DIAGONALS ONLY. ATTACH AT EACH END w/ (2) 12d TOENAILS. NAIL SHEATHING TO BLOCKING AT 6' O.C. w/ MINIMUM 8d NAILS. BLOCK4 BAYS BACK FROM GABLE TRUSS. WHEN SECOND BRACE IS REQUIRED, NAIL TO OPPOSITE SIDE OF BLOCKING. TRUSSES AT 2'-0" O.C. MAX. 3 SEE PLAN FOR ATTACHMENT OF ALL STRUCTURAL SHEATHING. TRUSS ANCHOR 3 1. AT VERTICALS 3'-6' TO 6'-6' USE ONE SEE CONN. CHART 2x4 "L" BACK. BOND BEAM PER P 2 AT VERTICALS OVER 6'-6' TO 8'-4" USE (2) 2x4 'L' BACKS (1 EA. SIDE) (OR FASCIA 2x SHTG. FRAME PER CASE 3 BELOW). SEE ARCH. BLOCKING DRAWINGS 3. AT VERTICALS OVER 8'-4" TO 14 8' CMU WALL OR USE ONE 20 'L' BACK AND AN LINTEL, SEE PLAN SHEATHING PER ADDITIONAL DIAGONAL BRACE IS REQUIRED FOR REINFORCEMENT PLAN AT THE PEAK AND AT EVERY OTHER MASONRY VERTICAL MEMBER IN THIS RANGE. ATTACH THE DIAGONAL AT MID HEIGHT AND TO THE 2x4 DIAGONAL BRACING w/ (5) 12d BLOCKING BELOW THE ROOF SHEATHING w/ COMMON NAILS TO BLOCKING AND "L" (5) 12d's AT EACH END. IN ADDITION TO TO THE BACK. UNLESS NOTED THE SECOND DIAGONAL, A STRONGBACK IS / OTHERWISE PLANS, PROVIDE ALSO REQUIRED AT THESE VERTICALS AND A ONE BRACE AT THE PEAK AND THE MUST BE ATTACHED TO EACH °L' BACK I REMAINDER"AT 48° O.C. DIAGONALS NTH (2) 12d's AND ONE SIMPSON H2.5A OVER 8'-0MUST HAVE AN OR ONE USP RT5 CONNECTOR. TRUSS ANCHOR ADDITIONAL "T' BRACE ATTACHED SEE CONN. CHART TO THE NARROW EDGE w/ /12d's SIDE NAIL ALL °L' BACKS AND FRAMING PER PLAN AT 6' O.C.. "T" BRACE LENGTH TO STRONGBACKS w/ 12d's AT 6' O.C. NOTCH BE THE DIAGONAL'S LENGTH MINUS 'L' BACKS AT TOP AND BOTTOM. 12' FROM EACH END. WOOD (-R09BDUTCH HIP GA_BLE TRUSS BRACI�GDETAIL .� "X'-10% v 'X"-10% HOUSE WIDTH `� I HOUSE WIDTH RIDGE ' X RIDGE —' � GABLE END � 7� — QQ GABLE END __.L_ — J BOSTON HIP GABLE z "X" = 10% OF HOUSE WIDTH 3 0 ® /7 C� RIDGE ROOF SHEATHING NAILS ROOF FASTENING ZONES SHINGLE: 7/16' SPAN RATED PLYWOOD OR OSB 8d RING SHANK 0.113" x 2-3/8" 1 2 3 OFFSET DIMENSION "X" = 10% HOUSE WIDTH "X" "X" 0�15/32' SPAN RATED PLYWOOD PANEL EDGES 0 SUPPORTS (1) 6" O.C. 6' O.C. 4" O.C. PANEL FIELD 1 6" O.C. 6" O.C. 6" O.C. METAL 15/32' SPAN RATED PLYWOOD w/24 GA. 19/32' SPAN RATED PLYWOOD w/26 GA. NOTES: 1. LONG SIDE OF SHEATHING TO BE PERPENDICULAR TO TRUSSES OR RAFTERS —TYPICAL. 2. EDGE SPACING ALSO APPLIES OVER GABLE END WALLS OR TRUSSES. 3. FASTENING ZONES 2 AND 3 ARE EQUAL TO 10% OF TOTAL HOUSE WIDTH, DIMENSION "X" OFFSET FROM ROOF EDGE. 30' WIDE HOUSE = 3' ZONE, 40' WIDE HOUSE = 4' ZONE, 50' WIDE HOUSE = 5' ZONE, 60' WIDE HOUSE = 6' ZONE R11 ROOF SHEATHING ATTACHMENT DIAGRAM 2x4 OUTLOOKER PER DRAWINGS 2x4 FASCIA SHEATHING PER PLAN. — OR — GABLE TRUSS PER PLAN 2x4 BETWEEN EA.� OUTLOOKER wA2) 10d TOENAILS _ EDIMENT BLOCKING @ GABLE VALLEY SET TRUSSES AT 2e O.C. ROOF SHEATHING PER PLAN SHEATHING PER —OR- D PLAN. (1) SDWC15600 TRUSS SCREW TO EVERY TRUSS BELOW PRE-ENGINEERED ROOF TRUSSES 0 MAX. 24' O.C. SHEATHING PER PLAN. GABLE TRUSS PER PLAN SHEATHING PER ARCH , lx4 FURRING AT INSTALLED PER MANUF. MAX. 16' O.C. w/ (3)10d AT EA TRUSS (Sol EXTERIOR CEILING FURRING SCALE: N.T.S. VALLEY SET TRUSSES AT 24" O.C. ROOF SHEATHING PER PLAN SHEATHING PER PLAN. -�- --,----,---- - - - - 2x4 PURUN 0 EA VALLEY TRUSS. NAIL TO COMMON TRUSS w/(3) 16d GUN NAILS BOTTOM CORD OF VALLEY TRUSS NAILED TO PURUN w/ 10d GUN NAIL 0 8' O.C. 20 LADDER FRAMING AT 24' O.C. REQ'D AT — STRUCTURAL OVERHANGS GREATER THAN 12°. ATTACH TO TRUSS SHEATHING SEE PLAN TOP CHORD w/ (2)-16d NAILS AT 24' O.C. FOR ATTACHMENT CONT. 2x6 w/ (2) 12d NAILS ---�,_ PRE ENGINEERED STRUCTURAL SHEATHING PER PLAN TRUSSES AT 24" O.C. 2x BLOCKING BETWEEN EA TRUSS MEMBER OR TRUSS WEB. 2x4 BLOCKING AT 2'-0' O.C. w/ (2) 12d TOE NAILS EACH END TO TRUSS _ 2x LEDGER w/2-10d 0 EA CROSSING TRUSS MEMBER FOR ROOF SHEATHING NAILING BOND BEAM PER SHEATHING PER PLAN PLAN AND SCHEDULE META16 AT BLOCKING w/l/4' 8' CMU WALL SEE PLAN MAX. GAP FROM TOP OF FOR VERT. RONF. WALL TO BOTT. OF BLOCKING R07 V&LBRACING AT NON -BEARING EXTERIOR WALL STRUCTURAL SHEATHING PER PLAN PRE ENGINEERED — TRUSSES AT 24' O.C. TRUSS ANCHOR PER PLAN BOND BEAM PER PLAN SHEATHING AND SCHEDULE PER PLAN —ff)PL R08B WALL BRACING AT BEARING WALL 20 BLOCKING AT DIAGONALS ONLY. ATTACH AT EACH END w/ (2) 12d TOENAILS. NAIL SHEATHING TO BLOCKING AT 6' O.C. w/ MINIMUM 8d NAILS. BLOCK 8'-0' BACK FROM GABLE TRUSS. 2x4 DIAGONAL BRACING w/ (5) 12d COMMON NAILS EA. E4ND 0 32' MAX. SPACING IF LENGTH IS LESS THAN 4'-O' USE 24 'L' BACK, IF LENGTH IS GREATER THEN 4'-0' USE (2) 20 'L' BACKS. NAIL 'L' BACKS w/12d 012'0.C.(NOTCHED 0 TOP w/2-12d TOENAILS 'L' BACK -EXTEND 6' PAST LOWER ROOF SHEATHING SHEATHING PER PLAN—' R09C PARTIAL GABLE END TRUSS DETAIL PARTIAL GABLE PRECAST LINTEL GRAVITY LOAD TABLE 06/29/11 LOADS LISTED HAVE BEEN CALCULATED OR COMPILED FROM APPROVED MANUFACTURERS: CAST-CRETE, LOTT'S CONCRETE, QUALITY PRECAST CO. MAXIMUM LOAD (PLF) APPROX. LINTEL LENGTH MAX. CLEAR OPENING TYPE A 8" LINTEL 8" TYPE B 8" TYPE C 12" TYPE B 12" TYPE C 14" TYPE B** 14" TYPE C** 16" TYPE B 16" TYPE C 20" TYPE B 20" TYPE C 24" TYPE B 24" TYPE C 28" TYPE B 28" TYPE C 32" TYPE B 32" TYPE C 2'10" 1'6" 2231 3069 3719 3280 5163 6607 8054 9502 10000 3069 4605 5206 6113 7547 8974 10000 10000 3'6" 2'2" 2231 3069 3719 3280 5163 6607 1 8054 9502 10000 3069 4605 5206 6113 7547 8974 10000 10000 4' 0" 2'8" 1783 2561 2751 3280 3820 4890 5961 7034 8107 2561 4605 5206 6113 7547 8974 10000 10000 4'6" 3' 2" 1343 1969 2110 2992 2931 3756 4576 5400 6224 1969 4375 5206 6113 7019 8672 10000 10000 V 8" 3' 4" 1217 1349 1438 1716 1999 2560 3132 3686 4249 1349 3090 4567 5365 4766 5817 7074 8203 5'4" 4'0" 1006 1349 1438 1716 1999 2560 3132 3686 4649 1349 3090 4567 5365 4766 5817 7074 8203 5' 10" 4-6- 860 1105 1173 16M 1631 2090 2549 3009 3470 1105 2622 4242 4360 3942 4889 5817 6662 66" 5' 2" 710 1232 2177 3738 3480 3031 3707 4383 5061 1232 2177 2738 3480 5381 8360 8625 7590 7'6" 6'2" 570 991 1729 2108 2632 2205 2698 3191 3685 991 1729 2108 2632 3898 5661 4742 5501 8'4" 7'0" 488 699 1160 1516 1626 2564 3486 2818 3302 699 1245 1516 1843 2564 3486 2964 3387 9'4" 8'0" 416 699 1160 N/A 1625 2564 3486 2818 3302 699 1245 N/A 1843 2564 3486 2964 3387 10-6" 912" 354 535 890 N/A 1247 2093 2777 2163 2-536 535 1054 N/A 1533 2093 2781 2259 2615 11'4" 10,0" 315 567 890 N/A 1366 1846 2423 3127 4006 567 945 N/A 1366 1846 2423 3127 4006 12' 0" 10'8" 292 525 873 N/A 1254 1684 2193 2805 3552 525 873 N/A 1254 1684 2193 2805 3552 12'6" 11'2" 277 471 755 N/A 1075 1428 1838 2316 2883 471 755 N/A 1075 1428 1838 2316 2883 IT 4" 12'0" 255 471 755 N/A 1075 1428 1838 2316 2535 471 755 N/A 1075 1428 1838 2316 2883 14'0" 12'8" 239 424 706 N/A 1002 1326 1697 2127 2278 424 706 N/A 1002 1328 1697 2127 2630 14'8" 13'4" N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 783* N/A 1234* 1421* 1779* 2188* 2662* 15' 4" 14' 0" N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 710* N/A 1160* 1331* 1660* 2032* 2459* 17'4" 16' 0" N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 548* N/A 952* 1117* 1379* 1671* 1997* 1914" 18'0" N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 420* N/A 750* 960* 1177* 1415* 1676* 20' 0" 18' 8" N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 340* N/A 598* 845* 1114* 1345* 1468* LSTRESSED W/2" RECESS U-LINTELS A =Unfilled no Rebar; T e B =Continuous Grout, Steel per Plan in Bond Beam Only; Type C = Continous Grout, Steel per plan in Bond Beam &Lintel C.O.A.# ARCHITECTURE: AA26002802 C.O.A.# ENGINEERING: 29349 0 THOMAS A. WEBER, PE P.E. # 73242 FLORIDA ■ BENJAMIN NIESE, PE P.E. # 86025 FLORIDA 10/14/20 DATE t`1111l111//� J, ;b ATE "I OR101' AL O O O CO 00 M00 0 v o n� 45 Q) c'tj U 0 co •� •O V10 w-4 0 CJ� Co as N *PulteGroup- 10M1 S �fl 0 M 0 ,.y -10 O w O Q w w p° 0�/ �i W PRODUCT MANAGER RELEASE I Mir. vv /vv /vvvv PROJECT TYPE SPECIFICATION LEVEL Nte 1PLAN NAME Hi h ate NPC WED NU ER 2811.5W SHEET S4.1 A ..I _a" uld.iu'xULw�w, .u�aunu� ..e i . � � s,w r. ,ua. au�ruuu�rr+u_. ; _... :.d.�.-......l • � � : _4. , —xf - u � =u.... a � a, rW u.. �... ar � u. A i . ,., .. ., , u . i:.. � fr4ur•���_ r. r..�... _ .-....u........�rr..... ��.u�_. .�... _ ° ° r ° a a ° a a a a a a ° a °---NOTE: PROVIDE BLOCKING AT ALL a a ° SHEATHING EDGES. a ° a a a a a a a a a a a a a a a a a a a a a a ° a a a a a o o 0 ° ° r AIL a o SPACING AT ° ° 0 ° e o a o ° 0 0 12 IN ° r FIELD ° ° o a a o e ° 0 0 ° a ° a ° o ° ° o ° ° o EXTERIOR WALL SHEATHING SHEATHING NAIL VERTICAL HORIZONTAL FIELD BLOCKING REQUIRED (MIN) SIZE SPACING SPACING SPACING REQUIRED F7/16' SHEATHING 8d 3' O.C. 3' O.C. 12' O.C. ALL EDGES SINGLE NAIL EDGE -SPACING 1 /2' 1/2 S e e 0 1 /2' DOUBLE NAIL EDGE SPACIN( `2x4 BLOCKING NAILING_v<rxl SHEATHING SPLICE -SANE THICKNESS AND STUD SPACING PER P STRUCTURAL SHEATHING PER PIAN STRENGTH AXIS ORIENTATION AS WALL SHEATHING W01 TYPICAL SHEATHING DETAIL TOP PLATE CONNECTOR: (2) SDWC15600 SCREWS 0 EA STUD DOUBLE 2x TOP PLATE MID SPAN BLOCKING BETWEEN EACH STUC 2X P.T. SOLE PLATE w/ 1/2" DIAM. ANCHOR BOLTS (10 + 2) AT 32" O.C. MAX. w/7" EMBEDMENT OR 5/8" DIA. EXP. BOLTS AT 24" O.C. W/1800 # ALLOWABLE TENSION MIN. OR 1/2" DIA EXP. BOLTS AT 24" O.C. W/1200 # ALLOWABLE TENSION MIN. ALSO AT CORNERS & JAMB w/ 30 PLATE WASHERS IDS AT 16' O.C. iING PER PLAN PLATE CONNECTOR: WC15450 SCREWS 0 EA STUD �-- REFER TO FOUNDATION PLAN FOR FOOTING SIZE AND LOCATION LOAD BEARING WALL w/UPLIFT W10 Lu STRUCTURAL SHEATHING. REFER TO STRUCTURAL SHEETS FOR NAILING & OTHER REQ. 12 _�QPER ELEV. INTERIOR EXTERIOR GABLE END SHEATHING SHEATHING NAIL VERTICAL HORIZONTAL FIELD BLOCKING REQUIRED (MIN) SIZE SPACING SPACING SPACING REQUIRED 1 16' MIN 8d 3" O.C. 3' O.C. 12' O.C. ALL SHEATHING EDGES W02 GABLE END SHEATHING DETAIL INSULATION AS PER SPECS. PRE-ENGINEERED ROOF TRUSSES. REFER TO TRUSS MFGR. DRAWINGS. ROOF SHINGLE (OR TILE PER SPEC) TRUSS STRAP PER STRUCT. DETAILS REFER TO PLAN FASCIA PER COMMUNITY SPEC SOFFIT & OVERHANG PER SPECIFICATIONS BOND BEAM PER PLAN PRECAST LINTEL PER PLAN OPENING w/ PRECAST SILL PER PLAN SEE STRUCT. FOR ALL REINFORCEMENT REQUIREMENTS EXTERIOR SEE STRUCT. DETAILS FOR VARIATIONS 0'—O" FINISHED GRADE MONOLITHIC FOUNDATION, SEE STRUCTURAL DETAILS FOR WIDTH, DEPTH & REINF. REQ. W31 IY�. 1-STORY WALL SECTION STRAP INSIDE FACE OF WALL PER — W10 WHEN TRUSS STRAPS INSTALLED ON INSIDE (NON -SHEATHED) FACE OF WALL — EDGE NAIL SHEATHING MTS16 FROM EA. TRUSS TO HDR. SIMPSON H2.5A ®TOP &BOTTOM OF PER PER PLAN DBL 2X TOP PLATE. BOTTOM 2X OF TOP AS REQ'D, PLATE TO BE SPLICED OVER A STUD. OPENING FRAMING (JACK STUDS ONLY) STRAPPING AT INTERIOR PROVIDE 48' LAP SPLICE w/ (3) 10d FACE PER PLAN COMMON NAILS AT ENDS. NAIL PLATES DBL 2X TOP PLATE. BOTTOM 2X OF TOP CONT. w/ 10d COMMONS AT 16' O.C. PLATE TO BE SPLICED OVER A STUD. PROVIDE 48' LAP SPLICE w/ (3) 10d COMMON NAILS AT ENDS. NAIL PLATES HEADER PER PLAN, (2) PLY 6 1 NAILS 31EGAI STUD TO (6) 10d CONT. w/ 10d COMMONS AT 16' O.C. MIN. ADDT1()NAL JACK STUD ( ) AND CONNECTORS (6) 10d NAILS KING STUD REQUIREMENTS PER PLAN. TO HEADER (MIN 3 EA PLY) (1) SIMPSON LSTA24 w/ (18) 10d FASTEN WALL SHEATHING NAILS U.N.O - CENTER ON BOTTOM (1) SIMPSON LSTA18 AT 3' O.C. ALL AROUND HEADER CENTER ON HEADER. OPENING CONNECT WALLS PER W10 DETAIL @— STRUCTURAL SHEATHING PER PLAN INTERIOR NON -SHEATHED WALLS ( ON OPPOSITE SIDE OF WALL) DOUBLE ill AS REQ. FOR 2x STUDS AT 16" O.C. SHUTTER ATTACHMENT 2x STUDS AT 16' O.C. --- - I I I I SHEATHING PER PLAN 0 EXTERIOR — WALLS AND SHEAR WALLS (ON OPPOSITE SIDE OF WALL) EDGE NAIL SHEATHING I I I I (1) SP4 TO KING & JACK STUD U.N.O.- PER PLAN I I I I EDGE NAIL SHEATHING PER PLAN INT FINISH WOOD BUCK ATTACHMENT: 1x WOOD lx CUSTOM PT BUCK TO MASONRY. MATCH FRAME WIDTH, ATTACH w/"T" 1X PT BUCK NAILS 04" FROM ENDS AND 12" O.C. REMAINDER. ATTACH WINDO THRU BUCK INTO MASONRY PER FLORIDA PRODUCT APPROVAL ATTACH WINDOW PER FLORIDA PRODUCT APPROVAL SILICONE SEALANT FINISH PER ELEAVATION II II =LL=JL NOTE: FOR EXTERIOR BEARING WALLS ONLY inin� TYPICAL FRAMED BEARING WALL v v v v i'M EXTERIOR CONC.WALL GARAGE DOOR AND TRACK, INSTALLED PER MANUFACTURERS SPECIFICATIONS. yr i�r ,�,�TYPICAL WINDOW ATTACHMENT �DET_AIL, INT FINISH WOOD BUCK ATTACHMENT. tx WOOD 2x OR GREATER BUCK TO MASONRY BUILT-UP THICKNESS <2 1/4' 2x PT BUCK = 1/4"00" TAPCONS 04" FROM ENDS AND 12" O.C. REMAINDER. w/1 1/4' EMBEDMENT ALTERNATE: ACH DOOR PER RIDA PRODUCT IROVAL 'K MOULD SH PER ELEAVATION ,��TYPICAMD OOR ATTACHME4TDETAIL tY IJ EBAR, CONT. IN BEAM BEAM PER PLAN EBAR VERTICAL ED 25" MIN. U.N.O. EBAR VERTICAL IN FILLED CELLS, PLAN). EBAR VERTICAL ED 25" MIN. U.N.O. CLEAN OUT AT ALL D CELLS. FOUNDATION PLAN DETAILS FOR FOOTING 'ORCING. IV Lnf 1111­1%,MLJ TYPICAL FILLED CELL WEAIL W19 TRUSS BOTTOM CHORD PER MANUF. 0 24' O.C. - EDGE NAIL SHEATHING TO TOP PLATE AND TOP AND BOTTOM OF HEADER PER PLAN —_ HEADER PER PLAN, (2) PLY MIN, ADD JACK/KING STUDS AND CONN. REQ. PER PLAN. DOUBLE UPPER SILL AS REQ. FOR SHUTTER ATTACHMENT EXTERIOR WALLS & SHEAR WAILS ONLY, FASTEN SHEATHING AT 3' O.C. ALL AROUND OPENING DOUBLE SILL AS REQ. FOR SHUTTER ATTACHMENT II II II II II II II II II II II II INTERIOR BEARING NOTE: TYPICAL FOR WALLS w/o SHEATHING, INTERIOR SHEAR WALLS AND EXTERIOR WALLS w/ SHEATHING • •� •' AT CMU WALLS USE 2x P.T. ATTACHED TO BLOCK OR LINTEL WITH POWER DRIVEN FASTENERS AT 12" O.C. • FASTENERS TO BE 1/8' DIA. MIN. AND EMBEDDED 3/4" MIN. :-. MINIMUM SHEAR CAPACITY TO BE 150. • Q' -LL 2x ANGLE AS REQUIRED w/ (2) 10d TOE NAILS AT EACH END. 2x6 WOOD BUCK ANCHORED TO CMU w/ 1/2"A' 'L' BOLTS OR 5/8'x6' SIMPSON TITEN HD'S w/ 2' WASHERS AT 24' D.C. & STRUCTURAL SHEATHING REQUIRED AT 2 SIDES IN WITHIN 6' OF TOP AND BOTTOM. OR (2) ROWS OF 1/4"d WINDOWS AND DOORS AND AT ENTRIES WITHOUT MASONRY SCREWS 012' O.C. STAGGER ROWS 6' BARREL FRAMING. SHEATH OUTSIDE ONLY WHEN FRAME M BUCK MASONRY BARREL FRAMING IS USED. 0"-16" MAX. GAP 20 FILL w/ 2" MAX. GAP BETWEEN BLOCKS. BLOCK AS REQUIRED AT WINDOW FASTENER LOCATIONS. EXTERIOR CONC.WALL _:- , - •�4 lx P.T. SHIM 1/4' DRIVE-IN ANCHOR W ,. a ' : a : -. NOTES: ALTERNATE ARCH TOP ::.` MINOR CHANGES MAY OCCUR ACCORDING TO INDIVIDUAL OPENING. GARAGE DOOR AND TRACK, INSTALLED PER MANUFACTURERS _-- IF WINDOW OR DOOR IS INSTALLED IN OPENING SEE "TYPICAL sPEaFlcnnoNs. 11 , WINDOW AND DOOR ATTACHMENT DETAIL" FOR INSTALLATION DETAIL. 1/2' x 2 1/4' HILTI SLEEVE ANCHOR OR EQUAL MIN. 1 1/2' EMBED INTO MASONRY. (1) PER BRACKET WHERE WINDOW FASTENER DOES NOT HAVE 2x BACKING, THE FASTENER MUST EXTEND THROUGH 1x SHIM INTO BASE MATERIAL ALTERNATE ARCH TOP FRAME M MASONRY PER THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. YPICAL GARAGE DOOR ATTACHMENT DETAIL ARCH FRAMING DETAIL W16 ru W13 sm STIR aim PER Y SDS SCREW 016' 0-t — STAGGERED EACH ME OF POST (RESULTNG IN Ir O.C. obERALL SPAM) GauMNs PER PLAN 4-PLY: )C x 5' SDS MTWS 5-PLY: Y4 x 6' SDS SCREWS 6-11Y. )C x 8' SDS SCREWS 1-PLY: Y x 8' SDS SCREWS 16 OR EQW. (TOP, IDLE AND BOTH) NAILS 0 8' O.C. -1 (2)1W MU 0 8' O.C. (m PLY) PINY MEW ALMkkl MEBi41Z STUD PACK DETAIL FOR (4) PLY OR MORE STUD MOMS #5 REBAR w/ A.C.I. STANDARD HOOK AT TOP. LAP PER GENERAL NOTES. MAY VARY, SEE PLAN BOND BEAM TOP COURSE LINTEL OVER OPENING - 8' KNOCK OUT BLOCK w/ #5 BAR GROUTED SOLID 15 VERTICAL BAR IN GROUTED CELL. 8' CMU WALL LAID IN RUNNING BOND. W18 TEPPED BOND BEAM OVER LINTEL C.OA.# ARCHITECTURE: AA260028M C.OA.# ENGINEERING: 29349 CJ THOMAS A. WEBER, PE P.E. # 73242 FLORIDA ■ BENJAMIN NIESE, PE P.E. # 86025 FLORIDA 10/14/20 GATE \\ 1111111 t j STATE i�i��s►s'Ir ....��p'�v�r�1 lir��ONAtr IE \� O 00 M � O A %-4 cr%•1 O v� V •� •O �a: rq C1.4 N as *PulteGroup- PRODUCT MANAGER RELEASE DATE: XX Ax /xxxx PROJECT TYPE Single Family SPECIFICATION LEVEL Pulte PLAN NAME Hi h ate NPC CHU NU ER 2811.500 SHEET S4.2