Loading...
HomeMy WebLinkAbout360 S Rosemary Ave Ste 400o io-IoU-UU�u City of Zephyrhills Fire Fax-813-780-0021 Permit Application Date Received Phone Contact for Permit ' Owner's Name Q [ _ Owner's Phone Number L Owner's Address 3W TIA fsemq Ary VG SvAe 400. l" 04a& TL 3.3 ci 0J Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address Job Addressi�V rh ( I I $ ; p 33 5 y ! Lot # Sub Division arcel # Tlazia WaA Storage - ANNUAL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material (Tier II or RQ Facility) ANNUAL Controlled Bum Hood Installation Emergency Generator < 30 kw LP/Natural Gas -Installation Emergency Generator > 30 kw LP/Natural Gas -ANNUAL Sale Fire Protection Maintenance - ANNUAL Places of Assembly -ANNUAL ®y emi ®n Sprinkler ❑ ❑ ❑ Recreational Burn Fire Alarm ❑ ❑ ❑ Sparklers Hood Cleaning ❑ ❑ ❑ El Sprinkler System Installations r 1 Hood Suppression ❑ ❑ ❑ Standpipes (Sprinkler Sys) Fire Alarm Installation Torch Roofing/Tar Kettle aFire Pumps Waste Tire Storage ANNUAL Flammable Application- ANNUAL Zq2_5700.Clro I Valuation of Project aFuel Tanks Q Other: Contractor Company v e 4� r]tire q�+.A Signature Registered / N Fee Current Y / N Address License # ELECTRICIAN Company Signature Registered Y / N Fee Current Y / N Address License # PLUMBER Company Signature Registered Y / N Fee Current Address License # MECHANICAL Company Signature Registered Y / N Fee Current Y / N Address License # OTHER Company Signature Registered Y / N Fee Current I Y / N Address License # Directions: Fill out application completely. Owner & Contractor sign back of application, notarized (Or, copy of signed contract with owner) If over $2500, a Notice of Commencement is required (Mechanical work over $5000) Supply two (2) sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel # - obtained from Property Tax Notice (http://appraiser.pascogov.com) F R E S O P Y T E M F � I R E S T O P Y S T M THROUGH -PENETRATION DETAIL SYSTEM No. F-A-IG 5 F RATIN05 - 2 HR 1. FLOOR ASSEMBLY - THE FIRE -RATED UNPROTECTED CONCRETE AND STEEL FLOOR ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED THE INDIVIDUAL D900 SERIES DESIGNS IN THE U.L. FIRE RESISTANCE DIRECTORY AND AS SUMMARIZED BELOW: A. CONCRETE - MIN 2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. B. STEEL FLOOR AND FORM UNITS* - COMPOSITE OR NON -COMPOSITE MAX 3 IN. DEEP GALV FLUTED UNITS AS SPECIFIED IN THE INDIVIDUAL FLOOR -CEILING DESIGN. MAX DIAM OF OPENING IS 6 IN. 2. THROUGH PENETRATIONS - ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND EDGE OF THROUGH OPENINGS SHALL B MIN 0 IN. (POINT CONTACTS) TO MAX 1-7/8 IN. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF MTALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. STEEL PIPE B. IRON PIPE C. CONDUIT - NOMINAL 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. D. COPPER TUBING E. COPPER PIPE 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: PACKING MATERIAL - MIN 1-1/2 IN. THICKNESS OF MIN 4 PCF DENSITY MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR AS REQUIRED TO ACCOMODATE THE REQUIRED THICKNESS OF FILL MATERIAL (ITEM 3B). FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR. AT POINT CONTACT LOCATION BETWEEN PENETRANT AND CONCRETE, A MIN 1/2 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE CONCRETE/PENETRANT INTERFACE ON TOP SURFACE OF FLOOR. FIRESTOP SYSTEM INC. - 4800 DW *BEARING THE UL CLASSIFICATION MARKING THROUGH -PENETRATION DETAIL SYSTEM No. F RATIN65 - 2 HR SECTION A -A 1. WALL ASSEMBLY - MIN 6-1/8 IN. THICK NORMAL WEIGHT OR LIGHTWEIGT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY U.L. CLASSIFIED CONCRETE BLOCKS*. MAX DIAM OF OPENING IS 14-1/8 IN. SEE CONCRETE BLOCKS (CAZT) CATERGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAME OF MANUFACTURER. 2. THROUGH PENETRATIONS - ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENINGS SHALL BE MIN 3/8 IN. TO MAX 1 IN. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF MTALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. STEEL PIPE B. IRON PIPE C. CONDUIT - NOMINAL 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. D. COPPER TUBING E. COPPER PIPE 3. FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 1-1/4 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH TOP SURFACE OF OF WALL. FIRESTOP SYSTEM INC. - 4800 DW *BEARING THE UL CLASSIFICATION MARKING FIRE ALARM NOTES: SEQUENCE OF OPERATION: 1. THE FIRE ALARM SYSTEM SHALL OPERATE AS FOLLOWS: A. MANUAL PULL STATION: 1) IDENTIFY THE INDIVIDUAL STATION ON THE SYSTEM CONTROL PANEL. 2) SOUND THE LOCAL AUDIBLE ALARM AT THE FACP. 3) ILLUMINATE THE ALARM RED LED. 4) SOUND AUDIBLE ALARM AND ACTUATE THE VISUAL ALARMS (STROBES) IN THE BUILDING. B. AN AREA SMOKE DETECTOR OR HEAT DETECTOR ,OR SPRINKLER WATER - FLOW SWITCH SHALL CAUSE THE FOLLOWING: 1) PROVIDE OPERATION AS DESCRIBED FOR MANUAL ALARM PULL STATION. 2) A SIGNAL DEDICATED TO THE SPRINKLER SYSTEM WATER -FLOW ALARM SHALL NO BE ABLE TO BE SILENCED. C. SMOKE DETECTORS FOR ELEVATOR RECALL: 1) PROVIDE OPERATION AS DESCRIBED FOR MANUAL ALARM PULL STATION. 2) REFER TO ELEVATOR RECALL SEQUENCE OF OPERATION. D. SMOKE DUCT DETECTORS 1) IDENTIFY THE INDIVIDUAL DETECTOR ON THE SYSTEM CONTROL PANEL. 2) SOUND THE LOCAL AUDIBLE SUPERVISORY ALARM AT THE FACP. 3) ILLUMINATE THE SUPERVISORY LED. 4 SHUT DOWN ITS RESPECTIVE AIR HANDLER UNIT. E. FLOW BELL : 1) FLOW BELL SHALL SOUND UPON THE ACTIVATION OF FLOW SWITCH ONLY. 2) FLOW BELL SHALL SOUND AS LONG AS THE WATER IS FLOWING. 3) FLOW BELL SHALL NO BE CAPLABLE OF BEING SILENCED FROM THE FACP. F. ACTIVATION OF ANY SUPERVISORY CIRCUIT OR TAMPER SWITCH SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: 1) IDENTIFY THE INDIVIDUAL CIRCUIT OR DEVICE ON THE SYSTEM CONTROL PANEL. 2) SOUND THE LOCAL AUDIBLE SUPERVISORY ALARM AT THE FACP. 3) ILLUMINATE THE SUPERVISORY LED. G. RECEIPT OF A TROUBLE SIGNAL AT THE FACP SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: 1) IDENTIFY THE ORIGIN OF THE TROUBLE ON THE SYSTEM CONTROL PANEL. 2) SOUND THE LOCAL AUDIBLE TROUBLE SIGNAL AT THE FACP. 3) ILLUMINATE THE TROUBLE LED. ALARMS, TROUBLES AND SUPERVISORY SIGNALS SHALL BE DISPLAYED ON THE MAIN FIRE ALARM PANEL AS WELL AS ON ALL REMOTE ANNUNCIATOR PANELS. ALARMS, TROUBLES AND SUPERVISORY SIGNALS SHALL BE TRANSMITTED TO A LISTED CENTRAL STATION. CENTRAL STATION / TRANSMISSION OF SIGNALS / MONITORING - ALL SIGNALS (ALARM/ TROUBLE/SUPERVISORY) WILL BE TRANSMITTED TO THE CENTRAL STATION. - THE MEANS OF TRANSMISSION IS WIRELESS DIALER. - ALL SIGNALS WILL BE TRANSMITTED AS FOLLOWS: A POINT ADDRESSABLE SIGNAL WILL BE TRANSMITTED TO THE CENTRAL STATION, SYSTEMS POINTS WILL BE IDENTIFY AT THE CENTRAL STATION AS FOLLOW: DEVICE TYPE ( PULL STATION, SMOKE, ETC) + DEVICE LOCATION (FLOOR + GENERAL DESCRIPTION) + INDIVIDUAL BUILDING PHYSICAL ADDRESS OR BUILDING NUMBER. - THE FIRE ALARM DIALER IS AN OPTIONAL BOARD THAT MOUNTS INSIDE I THE FIRE ALARM CABINET ON TOP OF THE FIRE ALARM MAIN BOARD. CODES & FLAN NOTES ALL DRAWINGS ARE SCALED TO 1/8 = 1Ft UNLESS OTHERWISE NOTED. COORDINATE WITH SPRINKLER CONTRACTOR EXACT LOCATION OF ALL TAMPER AND FLOW SWITCHES. INSTALL STROBE BOX FOR FUTURE ADA USE IN ALL 1ST FLOOR APARTMENT'S BATHROOMS. CONFIRM LOCATION OF POWER SUPPLIES IN BLDGS PRIOR TO ROUGH IN. REFER TO FLOOR PLANS FOR LOCATION OF DUCT DETECTORS (SUPPLY OR RETURN SIDE), COORDINATE WITH MECHANICAL CONTRACTOR THE ACTUAL LOCATIONS OF THE AHUs. ALL STROBES WILL BE SET @ 75cd UNLESS NOTED. CEILING HEIGHT IS 10ft UNLESS NOTED. UNDERGROUND WIRE USED AS SLC FOR COMMUNICATION BETWEEN BUILDINGS IS SUITABLE FOR WET LOCATIONS / DIRECT BURIAL. ANY PROPOSED INTERCONNECTION OF PANELS WILL BE A "NON -LATCHING" CONFIGURATION PANEL RESET FROM 1 LOCATION. FIRE ALARM SYSTEM PROVIDED IS FULLY ADDRESSABLE. SMOKE DETECTORS FOR SMOKE COMPARTMENTS WILL BE PROVIDED AS PER NFPA-72 17.7.5.6.5.1 (A) COORDINATE WITH MECHANICAL CONTRACTOR LOCATION OF SMOKE DAMPERS SINGLE STATION 120 AC SMOKE DETECTOR AND C/O DETECTORS PROVIDED BY ELECTRICAL CONTRACTOR ON SEPARATE PERMIT. ELECTRICAL LOAD, PANEL, BREAKER LOCKOUT IS ON SEPARATE PERMIT PERMIT #########. FBC 107.2 INSTALLATION SHALL BE IN ACCORDANCE WITH 2O20 FFPC 7TH ED., NFPA 72 2016 ED NFPA 1 2018 ED., NFPA 101 2018 ED. AND NFPA 13 2016 ED. 24/5 STANDBY TEST IS REQUIRED BEFORE FINAL FIRE. IF BUILDING IS OCCUPIED DURING THIS TEST, FIREWATCH WILL BE REQUIRED. ALL AUDIBLE DEVICES LOCATED INSIDE SLEEPING AREAS MEET NFPA-72 (2016) 18.4.5.3 FOR LOW FREQUENCY REQUIREMENTS - ALL NEW SYSTEMS SHALL INCLUDE A DOCUMENT CABINET. ** 24/5 STANDBY TEST REQUIRED IF ANY PART OF THE BLDG IS OCCUPIED BY TENANTS DURING THIS TEST, A FIRE WATCH IS REQUIRED FROM 7AM-7PM. ELECTRICAL MOUNTING BOX FOR THE CEILING MOUNTED NOTIFICATION DEVICES. "CADDY" T-GRID BOX HANGER ACOUSTICAL TILE CEILING SUPPORT, OR EQUAL. "CADDY'- GRID SUPPORT FRAMING. REFERENCE NO. CEC 30-302(3). CEILING GRID ELECTRICAL BACK -BOX ATTACHMENT FIRE ALARM DEVICE LEGEND SYMBOL DEVICE DESCRIPTION FACP 0 FIRE ALARM CONTROL PANEL w FO REMOTE ANNUNCIATOR PANEL z_ m U FCPS 0 POWER SUPPLY EXPANDER wFp FIRE ALARM TERMINAL CABINET z d Mlc 0 REMOTE MICROPHONE PANEL AUDIO AUDIO PANEL DIALER 0 FIRE ALARM DIALER SYMBOL DEVICE DESCRIPTION Ell HORN/STROBE WALL MOUNT FQ< Wp HORN/STROBE OUTDOOR CM HORN/STROBE CEILING MOUNT Hl< LF LOW FREQUENCY FREQUENCY O SPEAKER/STROBE WALL MOUNT U Wp SPEAKER/STROBE OUTDOOR LL CM SPEAKER/STROBE CEILING MOUNT O Z ❑s SPEAKER F' STROBE F' Wp STROBE OUTDOOR CM STROBE CEILING MOUNT ©4 LOW FREQUENCY HORNS SMOKE SOUNDER BASE SPRINKLER BELL SYMBOL DEVICE DESCRIPTION PULL STATION FF] FEWId PULL STATION OUTDOOR 8 SMOKE PHOTO DETECTOR BION SMOKE ION DETECTOR O BcO SMOKE C/O DETECTOR Q ® HEAT DETECTOR F- z 1 M:,:::- DUCT DETECTOR SUPPLY SIDE DUCT DETECTOR RETURN SIDE ©s g FLOW SWITCH ® BEAM DETECTOR M❑ MONITOR MODULE < MINI -HORN (DwP HEAT DETECTOR WEATHER PROOF u) SYMBOL DEVICE DESCRIPTION Os g TAMPLR SWITCH ® RELAY Z EOL END OF LINE RESISTOR U suRa SURGE SUPRESSOR DOOR HOLDER CO Rrs REMOTE TEST SWITCH c ❑ CONTROL MODULE LU LOCK BOX (PROVIDED BY OTHERS) U CEILING MOUNTED SMOKE/HEAT DETECTOR 24" MIN HANDICAP BEDROOM STROBE MORE THAN TWO APPLIANCES IN THE SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW SHALL FLASH IN SYNCHRONIZATION. 80" MIN 96" MAX NFPA 72 2016 (ADAAG) 80" ABOVE HIGHEST FLOOR LEVEL OR 6" BELOW CEILING TO THE BOTTOM OF THE STROBE. WHICHEVER IS LOWER. FINISHED FLOOR 3' (MIN) PER NFPA 7 AUDIO/VISUAL & VISUAL -ONLY DEVICES A/C SUPPLY DIFFUSER CEILING MOUNTED NOTIFICATION DEVICE (TO BE WHITE). SEE PLAN FOR LOCATION. MANUAL PULL STATION 48" (ADA) TO THE WORKING MECHANISM 48" ALSO MEETS THE REQUIREMENTS OF NFPA 72 2016 5'-0 MAX FROM EXIT DOOR o MAGNETIC DOOR HOLDER ACCEPTABLE DO NOT INSTALL IN THIS AREA WALL MOUNTED HEAT DETECTOR - TO THE BOTTOM. WALL MOUNTED SMOKE DETECTOR - TO THE TOP. 4" 4" 12" (MAX) Q REMOTE /-ANNUNCIATOR w Q o X 0 o Ln IMPORTANT NOTE NOTE NOT ALL DEVICES SHOWN ON THIS DETAIL APPLY TO THIS PROJECT. SEE CHECK WITH MANUFACTURE'S INSTALLATION SHEET THE PLAN VIEW LAYOUT OF THE FIRE ALARM SYSTEM TO VERIFY WHICH FOR THE EXACT ROUGH -IN HEIGHTS, LOCATION OF DEVICES APPLY, AND WHICH DO NOT. j BACK BOXES, AND WIRING REQUIREMENTS. FIRE ALARM DEVICE MOUNTING GUIDE TYPICAL SPRINKLER CLOSET WITH FIRE ALARM PANEL > INSTALLATION DIAGRAM. • 10 g rJ 6 i/ �i • 1 m FACP m '- MAIN TAMPERS AND WATERFLOWS ,a = = Breaker Box d 2 FCPS EXTERIOR MAIN TAMPERS, BACKFLOWS, ETC. 3) Oti INSTALLATION NOTES: 1. 120voc Line in 1/2" or 3/4" EMT conduit, PVc or Flex supplied by electrical contractor. 2. 120voc surge protector, supplied by Fire Alarm contractor, Installed by Electrical Contractor on Electrical breaker Panel. 3. Splice Box, Installed and Supplied By Electrical Contractor. 4. FACP, Supplied and Installed by Fire Alarm Contractor. 5. FCPS, Supplied and Installed by Fire Alarm Contractor. 6. 3/4" EMT Conduit or Flex Supplied By Electrical Contractor. 7. PVC Box 6x6x4, Supplied and Installed by Electrical Contractor. 8. 3/4" PVC Conduit for Underground Connection Front/To other Fire Alarm Closets. 9. WaterFlow Sensor. 10. Water Tamper. 11. Surge Protector, Supplied and Installed BY Fire Alarm Contractor. 12. 3/4 EMT Conduit or Flex Supplied By Electrical Contractor. 13. 4 Square PVC Splice Box, Supplied and Installed by Fire Alarm Contractor, 14. 1/2" or 3/4" PVC Conduit or Seal tight Flex Supplied By Electrical Contractor. 15. 3/4" PVC Conduit for Underground Connection To Outside Tampers. 16. Single gong Box attached to Water Tamper, Supplied and nstolled By E13ctrical Contractor. 17. 4 Square Box with Rised P-Ring For Smoke Detector, Supplied By Electrical Contractor. 18. Breaker Lock, Supplied By Electrical Contractor. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUPPLYING ALL THE NECESSARY HARDWARE (BOXES, CONNECTORS, CONDUITS, Etc.) AS WELL AS PARTIAL INSTALLATION AS PER INSTALLATION NOTES. _�,.., - I. IYiWI V �vR.iVNo 1'G':li - --= __-=-- - - - _ =- - _ _ -7 If li.11 770 -� \\ _- -, --- l _ - I------ -- Building Type II - Bldg 1 _ Imo- 1 �' .; -�_� - .. I I _ � �• r 2 ' 13 I t _ a - Ot- o- r n t- 'I 9 1 - L rY ---I I _ ------------ ------------- Building Type I - Bldg 4 �I - _._ .. m SITE PLAN THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY SAMUEL P. DEAN, P.E. ON [11.282022] USING A SHA-t AUTHENTICATION CODE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. erie, rl,,- Fire Alarm & C mmunicati ns Cust mer Service is ur Greatest Techn I gy. SUPERIOR FIRE ALARM 8c COMMUNICATIONS 6201 JOHNS ROAD SUITE 9 TAMPA, FL 33634 81 3- 81 8- 4444 CERTIFIED ALARM SYSTEM :> CONTRACTOR 1 LICENSE EF 20001162 U. ., cn -IC7 S E >1 IC- -� N O N 0 0) -�-� 6b JZ O~ U 0 :T ICn A g a w � 0 O O b. tv LL �LL J Q Z CAD DATE: 9/9/2022 NO. ISSUE/REVISION DATE Digitally signed `. 5•.�GENS�. No 83915 by Samuel P. ^� Dean p'. STATE OF Date: 2022.1 1.28 T .0 P.,:� aPtk.Q. 09:20:02-05'00' SAMUEL P. DEAN P.E. CONSULTING ENGINEER REGISTRATION NUMBER 83915 CA # 29694 1503-A WEST BUSCH BLVD. TAMPA FLORIDA 33612 PHONE: (813) 961-3075 FAX: (813) 961-1031 email: sdeon@beltengineering.com I CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF ALL OF THE STRUCTURAL ELEMENTS AND SYSTEMS FOR THIS STRUCTURE HAVE BEEN DESIGNED TO BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION 2020. ALL OTHER ELEMENTS, SYSTEMS AND ASSEMBLIES ARE THE TOTAL RESPONSIBILITY OF OTHERS. 511EET: f I RE ALARM fA- I of 3 (X31) (X3) wnx iveX ivn% SYMBOLS 0 = HEAT DETECTOR 8 = SMOKE DETECTOR s �{] = F W H LE LO S WIT C SPRINKLER A = SPRINKLER HEAD j = HALL —"DO NOT USE LITE" THHN CIRCUNIT BREAKER MARKED "FIRE ALARM PANEL" 13T F 24" MAX. PROVIDE FLASHING —J "DO NOT USE ELEVATOR" LIGHT, INITIATED BY CAB Y MACHINE ROOM SMOKE DETECTOR. POWER ELEV. SHUNT s TO F.A. RECALL ELEV. Dcl ISC. PANEL PANEL CONTROL PANEL b 3'-0" MAX. ELEV. MACHINE ROOM L_< PIT HOISTWAY DETAIL NOTES 1. ELEVATOR RECALL (NFPA 72: 3-8, 15); SMOKE DETECTORS IN ELEVATOR LOBBIES, HOISTWAYS AND MACHINE ROOMS SHALL INITIATE ELEVATOR RECALL AND SHALL INITIATE BUILDING FIRE ALARM SYSTEM. THE SHUNT TRIP BREAKERS/SWITCHES SUPPLYING POWER TO THE ELEVATOR EQUIPMENT SHALL BE RESET MANUALLY, 2. ELEVATOR SHUTDOWN (NFPA 72, 3-8, 16.3); CONNECT WATER FLOW SWITCHES TO DISABLE ELEVATOR POWER VIA A SHUNT TRIP BREAKER DISCONNECT IN ELEVATOR MACHINE ROOM. 3. HEAT DETECTORS SHALL ENABLE SHUNT TRIP BREAKER ACTIVATION AND INITIATE FIRE ALARM SYSTEM PRIOR TO SPRINKLER APPLICATION. 4. THE CONTRACTOR SHALL VERIFY AND CONFIRM THE ELEVATOR FIRE RECALL SYSTEM WITH THE AUTHORITY HAVING JURISDICTION (AHJ) PRIOR TO SUBMITTING A BID. LP -PLP PLP 3C THHN CIRCUNIT BREAKER MARKED "FIRE ALARM PANEL" I - 1/4w 1/4w j L _ 1/4w LF ❑S �LF 1/4w 1/4w S S LF LF [q]®LF I III Building Type II - Second Floor Plan 2 3/32" = V-0" 1/4w 1/4w ! j 1/4w 1/4w 1/4w LF� 1/4w 1/4w LFOELF I 1/4w 1/4w / �\ 1/4w 1/4w LF LF �� I 1/4w❑❑ /4w LF❑❑LF I ! LF❑❑LF -- LFODLF � LF SLF [5]LF \ % OAS BOOSTER PUMP III® ELEV MEQH III -- — IL- yI /� li,ll : I STAIRS, tom, I STAIRS I - -- - _ F --- ELEC 1 F� -- 1/4w 1/4w LFO 1/4w fi14w LFO[CLIF I 1/4w 1 /4w LF Q�LF FnCP 1/4w 1/4w LFaF8 LF 1/4w ❑S LF 1/4w LF GOLF j RISER 1/4w 1/4w LF [C[_s7LF 1/4w 1/4w LF QS ❑S LF I, FFI i I I TS FS" : I ❑ QWP ALARM CONDITION ORIGIN ALT FLOOR PRI FLOOR FIRE HAT RELAY RELAY RELAY PRIMARY LEVEL KEY SWITCH, ELEVATOR X LOBBY DETECTOR ALL OTHER LEVELS ELEVATOR X LOBBY DETECTORS PRIMARY LEVEL ELEV. HOISTWAY X X DETECTORS ALL OTHER LEVELS ELEV. HOISTWAY DETECTORS X X HEAT DETECTORS ACTIVATE SHUNT TRIP ELEV. HOISTWAY ,Building Type 11 - First Floor Plan 1- 3/32" = V-0" THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY SAMUEL P. DEAN, P.E. ON [11.282022] USING A SHA-1 AUTHENTICATION CODE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. emu_ u rie, rl,,- Fire Alarm & Communications Customer Service is our Greatest Technology. ff SUPERIOR FIRE ALARM & COMMUNICATIONS 6201 JOHNS ROAD SUITE 9 TAMPA, FL 33634 813-818-4444 CERTIFIED ALARM SYSTEM CONTRACTOR 1 LICENSE EF 200011 62 TZ- � O � E SL E -E L U � Q 11`j L.L. V 1 � s SL >, >11 s N 73 C0 C+_ O 4_1 U CAD DATE: 9/9/2022 SAMUEL P. DEAN P.E. CONSULTING ENGINEER REGISTRATION NUMBER 83915 CA # 29694 1503-A WEST BUSCH BLVD. TAMPA FLORIDA 33612 PHONE: (813) 961-3075 FAX: (813) 961-1031 email: sdean@beitengineering.com 1 1 CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF ALL OF THE STRUCTURAL ELEMENTS AND SYSTEMS FOR THIS STRUCTURE HAVE BEEN DESIGNED TO BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION 2020. ALL OTHER ELEMENTS, SYSTEMS AND ASSEMBLIES ARE THE TOTAL RESPONSIBILITY OF OTHERS. SHEET: !I FIRE ALARM FA-2 of 3 1/4w 1/4w OLF LF ❑S I 1/4w 1/4w 1/4w 1/4w 1/4w LFgOLF LF:SI,❑S LF fi%4w 1/4w 1/4w 1/4w 1/4w 1/4w LF LF i LF LF �- - `\ LFw 1/4w 1/4w ❑S �LF �� LF �O LF QQLF ❑S LF , ELEV BUILDING - - - SERVICES e �. DAB MEC H B _ - - _--- - f - ' _- — + I STAIRS _ _ _ _ - STAIRS 1/4w LF 1 /4w I �I � I 1/4w \ -- I 1/4w 1/4w � � 1 /4w 1/4w � 1/4w 1/4w LF � LF�NLF Y/4w LF LF �LF ❑S LF LF 1/ r�1/4w �� 114w 1/4w LF Q�LF LI LIULF LF [EgLF -Building Type II - Fourth Floor Plan 2 3/32" = V-0" 1/4w LF �LF I I j 1/4w 1/4w 1/4w 1/4w I 1/4w LF LF LF ---:I [E�LF LF 1/4w 1/4w 1/4w 1/4w 1/4w 1/4w 1/4w 1/4w 1/4w LF ] LF LF QOLF V LF aN]LF LF [EN]LF F§]LF L III - _ - - ti uO� /' _ 1 8 Cex _ LrJ -- — -- �' F1 I1��� EXII, _�/ P�"L' 11c, F�� - _ 1/4w LFN]N]LF ❑S LF S S LF 1/4w 1 /4w 1/4w LF LF 194w LF 1/4w 1/4w LFw Low S LFw /4w 1/4w ❑❑ a0 F ❑ FL1 /4w 1 /4w 1/4w LF sOLF LF QFS�LF Building Type II - Third Floor Plan 3/32" = 1'-0" AREA OF REFUGE DEVICE LEGEND SYMBOL Code Reference: NFPA-72 2016 ed 24.10 ,IBC Code 2018 ed &NFPA-101 2016 ed.IV Pe DEVICE DESCRIPTION cex EMERGENCY PHONE - Z� COMMAND BASE STATION U UPS POWER SUPPLY BACKUP' � �J DISTRIBUTION MODULE z w - Q Q. I :D ELEVATOR LOBBY LEVEL 3 ELEVATOR LOBBY m®n,a o - Aslr>wer X _EVEL 2 I - - SHIELDED CAT5 CABLES IN CONDUIT; TYP. rTWO WIRE III O o 1 CONNECTION 1 DEDICATED BS � DISTRIBUTION 20A,1 P MODULE - CIRCUIT IN HOUSE REFUGE PANEL COMMAND U BASE STATION Q� DEDICATED 20A,1 P CIRCUIT BY SYSTEM � IN HOUSE LEVEL 1 MANUFACTURER PANEL DEDICATED TELEPHONE SERVICE TO MONITORED CALL CENTER - 2417 OPERATION. TWO WAY EMERGENCY COMMUNICATION SCALE: SCHEMATIC ONLY KEY NOTE: O1 BASE STATION (BS) SHALL BE LOCATED IN COMPLETE COORDINATION WITH LOCAL AUTHORITY HAVING JURISDICTION (AHJ AND FIRE MAR$HALL AT BEVEL 1 (LEVEL OF EXIT DISCHARGE). CALL BOXES (®) SHALL BE LOCATED AT ELEVATOR LOBBIES ABOVE LEVEL OF EXIT DISCHARGE. COORDINATE EXACT LOCATION OF EQUIPMENT IN ELEVATOR LOBBIES WITH ELEVATOR EQUIPMENT INSTALLATION, SHAFT FABRICATION AND ARCHITECTURAL FINISHES PRIOR TO ROUGH -INSTALLATION. SYSTEM COMPONENTS 1. BASE STATION: A. STAINLESS STEEL OR POWDER -COATED STEEL HOUSING, RED COIL CORD EMERGENCY HANDSET, 120VAC POWERED, WITH BATTERY BACK-UP POWER FOR 4 HOURS OPERATION OF ANY CALL BOX AND BASE STATION. B. AUDIBLE AND VISUAL INDICATOR THAT A CALL BOX HAS BEEN ACTIVATED. C. 24VAC POWER SUPPLY MODEL CAPABLE OF SUPPLYING POWER TO A MINIMUM OF 10 CALL BOXES 2. CALL BOX: A. MUST COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) B. HANDS -FREE SPEAKERPHONE WITH LED TO INDICATE STATUS OF CALL C. PROGRAMMABLE FOR SPECIFIC LOCATION AND MESSAGE AT CALL BOX. ALLOWS RESCUE PERSONNEL TO IDENTIFY LOCATION OF ACTIVATED CALL BOX. D. BRAILLE FACEPLATE LOCATED NO HIGHER THAN 48" FOR FRONT REACH AND 54" FOR SIDE REACH ABOVE GROUND LEVEL TO ENSURE CONFORMANCE WITH ADA REQUIREMENTS, THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY SAMUEL P. DEAN, P.E. ON [11,28,2022] USING A SHA-1 AUTHENTICATION CODE. PRINTED COPIES OF I THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST I BE VERIFIED ON ANY ELECTRONIC COPIES. u rip,, r Fire Alarm &Communications Customer Service is our Greatest Technology. SUPERIOR FIRE ALARM �c COMMUNICATIONS 6201 JOHNS ROAD SUITE 9 TAMPA, FL 33634 813— 818— 4444 CERTIFIED ALARM SYSTEM CONTRACTOR 1 LICENSE EF 20001162 l l 'Ili ill l III III''I1 tli In -�-� S s O � >, s ICI N C)m CAD DATE: 9/9/2022 SAMUEL P. DEAN P.E. CONSULTING ENGINEER REGISTRATION NUMBER 83915 CA # 29694 1503-A WEST BUSCH BLVD. TAMPA FLORIDA 33612 PHONE: (813) 961-3075 FAX: (813) 961-1031 I email: sdeanC�beltengineering.com I CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF ALL OF THE STRUCTURAL ELEMENTS AND SYSTEMS FOR THIS STRUCTURE HAVE BEEN DESIGNED TO BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION 2020. ALL OTHER ELEMENTS, SYSTEMS AND ASSEMBLIES ARE THE TOTAL RESPONSIBILITY OF OTHERS. FIRE ALARM FA-3 of 3 :D ELEVATOR LOBBY LEVEL 3 ELEVATOR LOBBY m®n,a o - Aslr>wer X _EVEL 2 I - - SHIELDED CAT5 CABLES IN CONDUIT; TYP. rTWO WIRE III O o 1 CONNECTION 1 DEDICATED BS � DISTRIBUTION 20A,1 P MODULE - CIRCUIT IN HOUSE REFUGE PANEL COMMAND U BASE STATION Q� DEDICATED 20A,1 P CIRCUIT BY SYSTEM � IN HOUSE LEVEL 1 MANUFACTURER PANEL DEDICATED TELEPHONE SERVICE TO MONITORED CALL CENTER - 2417 OPERATION. TWO WAY EMERGENCY COMMUNICATION SCALE: SCHEMATIC ONLY KEY NOTE: O1 BASE STATION (BS) SHALL BE LOCATED IN COMPLETE COORDINATION WITH LOCAL AUTHORITY HAVING JURISDICTION (AHJ AND FIRE MAR$HALL AT BEVEL 1 (LEVEL OF EXIT DISCHARGE). CALL BOXES (®) SHALL BE LOCATED AT ELEVATOR LOBBIES ABOVE LEVEL OF EXIT DISCHARGE. COORDINATE EXACT LOCATION OF EQUIPMENT IN ELEVATOR LOBBIES WITH ELEVATOR EQUIPMENT INSTALLATION, SHAFT FABRICATION AND ARCHITECTURAL FINISHES PRIOR TO ROUGH -INSTALLATION. SYSTEM COMPONENTS 1. BASE STATION: A. STAINLESS STEEL OR POWDER -COATED STEEL HOUSING, RED COIL CORD EMERGENCY HANDSET, 120VAC POWERED, WITH BATTERY BACK-UP POWER FOR 4 HOURS OPERATION OF ANY CALL BOX AND BASE STATION. B. AUDIBLE AND VISUAL INDICATOR THAT A CALL BOX HAS BEEN ACTIVATED. C. 24VAC POWER SUPPLY MODEL CAPABLE OF SUPPLYING POWER TO A MINIMUM OF 10 CALL BOXES 2. CALL BOX: A. MUST COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) B. HANDS -FREE SPEAKERPHONE WITH LED TO INDICATE STATUS OF CALL C. PROGRAMMABLE FOR SPECIFIC LOCATION AND MESSAGE AT CALL BOX. ALLOWS RESCUE PERSONNEL TO IDENTIFY LOCATION OF ACTIVATED CALL BOX. D. BRAILLE FACEPLATE LOCATED NO HIGHER THAN 48" FOR FRONT REACH AND 54" FOR SIDE REACH ABOVE GROUND LEVEL TO ENSURE CONFORMANCE WITH ADA REQUIREMENTS, THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY SAMUEL P. DEAN, P.E. ON [11,28,2022] USING A SHA-1 AUTHENTICATION CODE. PRINTED COPIES OF I THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST I BE VERIFIED ON ANY ELECTRONIC COPIES. u rip,, r Fire Alarm &Communications Customer Service is our Greatest Technology. SUPERIOR FIRE ALARM �c COMMUNICATIONS 6201 JOHNS ROAD SUITE 9 TAMPA, FL 33634 813— 818— 4444 CERTIFIED ALARM SYSTEM CONTRACTOR 1 LICENSE EF 20001162 l l 'Ili ill l III III''I1 tli In -�-� S s O � >, s ICI N C)m CAD DATE: 9/9/2022 SAMUEL P. DEAN P.E. CONSULTING ENGINEER REGISTRATION NUMBER 83915 CA # 29694 1503-A WEST BUSCH BLVD. TAMPA FLORIDA 33612 PHONE: (813) 961-3075 FAX: (813) 961-1031 I email: sdeanC�beltengineering.com I CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF ALL OF THE STRUCTURAL ELEMENTS AND SYSTEMS FOR THIS STRUCTURE HAVE BEEN DESIGNED TO BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION 2020. ALL OTHER ELEMENTS, SYSTEMS AND ASSEMBLIES ARE THE TOTAL RESPONSIBILITY OF OTHERS. FIRE ALARM FA-3 of 3 CAD DATE: 9/9/2022 SAMUEL P. DEAN P.E. CONSULTING ENGINEER REGISTRATION NUMBER 83915 CA # 29694 1503-A WEST BUSCH BLVD. TAMPA FLORIDA 33612 PHONE: (813) 961-3075 FAX: (813) 961-1031 I email: sdeanC�beltengineering.com I CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF ALL OF THE STRUCTURAL ELEMENTS AND SYSTEMS FOR THIS STRUCTURE HAVE BEEN DESIGNED TO BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION 2020. ALL OTHER ELEMENTS, SYSTEMS AND ASSEMBLIES ARE THE TOTAL RESPONSIBILITY OF OTHERS. FIRE ALARM FA-3 of 3 �. l51��C 3