Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
36018 Stable Wilk Ave
1�6,1 / )( t��r ABBREVIATIONS A.B. Anchor Bolt F.P. Fireplace P.T. Pressure Treated Abv. Above F.O.M. Face Of Masonry Pwd. Powder Room A/C Air -Conditioner Ft. Foot/ Feet Rad. Radius ADJ. Adjustable Ftg. Footing Ref. Refrigerator A.F.F. A.H.U. Above Finished Floor Air Handler Unit FIX Fixed Req'd. Required ALT. Alternate Galy. Galvanized Rm. Room B.A. Base Cabinet G.C. General Contractor Rnd. Round BF Bifold Door G.F.I. Ground Fault Interrupter RIS Rod and Shelf Bk Sh BookShelf G.T. Girder Truss SD. Smoke Detector Bm. Beam Hdr. Header S.F. Square Ft. Bot. Bottom Hgt. Height Sh. Shelves B.P. Bypass door HB Hose Bibb SHT Sheet BRG. Bearing Cir. Circle Int. Interior S.L. Side Lights Clg. Ceiling K/Wall Kneewall S.P.F. Spruce Pine Fir CJ Control Joint K.S. Knee Space Sq. Square Col. Column Laun. Laundry S.Y.P. Southern Yellow Pine Comm. Community Lay. Lavatory TB Towel Bar Comp. Compressor L.F. Linear Ft. Temp. Tempered C.T. Ceramic Tile LL Lintel Length Thik'n. Thicken D. Dryer LT. Laundry Tub T.O.B. Top of Block DB Door Bell Mas. Masonry T.O.M. Top of Masonry Dec. Ded. Decorative Dedicated Outlet Max Maximum T.O.P. Top of Plate Dbl. Double M.C. Medicine Cabinet TR TOWEL RING Dia. Diameter Mfgr. Manufacturer TIP TOILET PAPER Dis . P Disposal P Micro. Microwave Trans. Transom Window Dist. Distance Min Minimum Typ. Typical D.S. Drawer Stack M.L. Microlam U.C. Under Counter D.V. Dryer Vent Mir. Mirror UCL Under Cabinet Lighting D.W. Dishwasher U.N.O. Unless Noted Otherwise Ea. Each Mono Monolithic V. Shower Valves E.W. Each Way N.T.S. Not to Scale VB Vanity Base Elec. Electrical Opn'g. Opening Vert. Vertical Elev. Elevation Opt. Optional V.L. Versalam Ext. Exterior Pc. Piece VTR Vent through Roof Exp. Expansion Ped. Pedestal w Washer FBC Florida Building Code PH PHONE W/ With Fin. Flr. Finished Floor P.L. Parallam W/C Water Closet F.G. ixed Glass PLF Pounds per linear foot W.A. Wedge Anchor Flr. Floor Pit. HI. Plate Height Wd Wood Fdn. Foundation Pit Sh. Plant Shelf WP Water Proof Flr Svs Floor Svstem PSF Pounds per square foot REVISIONS 08-20-15 1.00 NEW BASE PLAN 12-8-15 2.00 FRAME —WALK REVISIONS limmENN/�R 1791 INDEX OF DRAWINGS SHEET DESCRIPTION SHEET No. CS COVER SHEET 1 FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS 4 ELECTRICAL PLAN 5 ROOF PLAN 6 FOUNDATION PLAN 7 ROOF FRAMING PLAN 8 LINTEL DETAILS SN STRUCTURAL NOTES SN1 DETAILS S3S STEM DETAILS S4 DETAILS S5 DETAILS SS RETROFIT DETAILS D1 SECTIONS & DETAILS WP WATERPROOFING DETAILS PA1.0 PRODUCT APPROVAL NUMBERS PA1.1 PRODUCT APPROVAL NUMBERS PA1.2 PRODUCT APPROVAL NUMBERS PA1.3 PRODUCT APPROVAL NUMBERS I hlAMCINr�L �r�Tl7' OE, \ / L , QJ:V1EWW I Y VI i1 y TYtNE z�� / � rrA r � MEAN ROOF 15 FT. HIGH TYPICAL FOR SINGLE STORY HOMES IMEAN ROOF 30 FT. HIGH TYPICAL I FOR 2 STORY HOMES THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID Notice to Builder & All Subcontractors It is the intent of Designer/Engineer listed in the titleblock of these documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Office at (407) 880-2333 immediately. No backcharges will be considered for reimbursement by the Designer/Engineer without advanced notification and approval by the Designer/Engineer. Payments will be made in accordance to the terms of the agreement. M O � r� Z Ln CD W co3 �U — O L_U E o _ M F— (6 o 0 in r— U Lu M @n �-.._ O U @ 'O M O NO a) L_ LL N ' U 'on o 0 O Y Q m u7 � Q O A0 B D. NCBDC C � N NLO N ,—Q\x cam, 6 co . a �; 0., a'� ° �',. 6 `,,. NaorruSf m Wa 8. N ¢ o;r 6a To the best of the Engineer's knowledge, infklNh,tion, and belief, the structural plans and specificati�As` contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O fmo Z � O ate-' 14 �(J MOO Q 1713_ Lrl Nr Z a L 0 I\ U" Q U I— fl- U fl. 00 Q � � Z Lu C:) J O W J 0 oZ 0 Zn 3> �o w Z a z� aQ fF wQC� �Zgo U z�zd C=7=)wZ OQ[ i0 w w W oZLn Z Z _ }o az U) 2: g� z -0 MLU S � '� 0 > U Q U 0 ILoo cV (� Lu oaoa t'V Zwo J w < z a Q fV QaQF�o E) Z w Z W N Lfi iii awo~ Q Q owo °YQ M M Q Z Z d' Z a � Ln o 0 Qz J = aZ r-) ri d t/) SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION N0. 10 O SHEET NO. CS in r A O 35-SH 16'-3" H.B. LU OZ LU OZ TILE \ \\ NW i oYt� \\\ NUJ t T _ i Ir� --- 30'-0" `"U io et 41-141 34 7 , \\\ CAFE - \\ FAMILY ROOM VAULT.CLG. \ VAULT. CLG. \\ I CARPET MICO r � PATIO T o \ r ---- W.H. O�' i- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - to - in 868 2:12L;E LINLi� A � N TYP @ 1 STORY A S3 „'FEAT CLFr' 9'-01, 3'-8" 2'-8" 4'-3" 6-10" T-7" 1 I Q G OPT. D 1OPT. / 6-0"" R ER 1'-5- VENT '- a' S4 S3 ---- — TH RU ROOF H1 I� F_ T o0 L o FIBERGLASS II— u_-I-------------- - O (4) 2x4 #2 SYP N I O D.W. �I o o M SURROUND I STUDS W/ USP - - 2'-0" — -- - V-6" :— - G I EI- � I HTT4@ BASEgly $K DIS r -5g' S �3411 z' s' z' 2 _ — -- OWN R'S M B/ T- S U I T P NT YN i� . _ T r+L _ __l_ - ---j Tr 8 0 Fl CLG --� 8'-0" FLAT GI LG. w�I _ a l _F _ l TILE': A R TILE CARPEJ cn LG. RANG � �o LAT C _ (D -gyp 5-SH I fn co = w O N W 12'18" H.B. —_I W W M I 5'-32 � - 11-4" C`' r —ir B4T-H .. . "IIFLAT CLG. -1 BEDROOM 250 8'-0" FLAT CLG. CARPET CARPET 9'-4" FLAT CLG. HALL f111 25-SH O O 3068 1 I ENTRY I 8'-0" FLAT CLG. I I 101, 20'-8" 15'-0" io A S3 8'-0" FLAT CL w = O CARPET I L6 W ri o av HEADER SCHEDULE MARK HEADER SIZE REMARKS H1 (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE H2 (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE H3 (2) - 2X10 #2 SYP W/ 1/2" FLITCH PLATE H4 (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE H5 (2) - 1 3/4" X 11 1/4 LVL 2.0E Fb=2950 H6 (2) - 1 3/4" X 9 1/4" LVL 2.0E Fb=2950 H7 (2) - 1 3/4" X 16" LVL 2.0E Fb=2950 H8 (2) - 1 3/4" X 71/4" LVL 2.0E Fb=2950 (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20 X 26 18 X 25 S.H. 13 20X388 18 X37 S.H. 14 20 X 501 18 J X 50 S.H. 15 20 X 63 18 X 62 S.H. 16 20X72 18 X71 S.H. J 32 27 1/4 X 26 26 X 25 S.H. J 33 27 1/4 X 38 N/A S.H. j 34 27 1 X 50 1 N/A S.H. J 33 N/A 26 x 37 S.H. 34 N/A 26 x 50 S.H. J 35 27 j X 63 26 X 62 1/2 S.H. J 36 27 1 X 72 26 X 71 1/2 S.H. 22 37 j X 26 36 1 X 25 1/2 S.H. 23 37 j X 38 36 1 X 37 3/4 S.H. 24 37 j X 50 j 36 J X 50 S.H. 25 37 X 63 361 X 62 1/2 S.H. 26 37 X 72 36 j X 71 1/2 S.H. DOUBLE 2 WIDE 75" TALL 73 J WIDE S.H. 32 54 X 26 52 X 25 S.H. 33 54 X 38 52 X 37 S.H. 34 54 X 50 52 J X 50 S.H. 35 54 X 63 52 J X 62 j S.H. 36 54 X 72 52 j X 71 } S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 1 3/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors, equipped with self -closing device. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.11, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Ed. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is Iocated.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic , crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above flr. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED-EXPOSURE"C" OA +25.6 / -27.8 © +25.6 / -34.3 CO +24.5 / -26.7 OD +24.5 / -31.9 OE +23.0 / -25.2 �F +23.0 / -28.9 GO SEE SN SHEET OH SEE SN SHEET 140 MPH wwwiii NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALL LEGEND MASONRY HGT. @ 9'-4" A.F.F. TYP. 2x FRAME WALL o> INTERIOR BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION 1ST FLOOR LIVING AREA 1817 LIVING TOTAL 1817 GARAGE 427 FRONT ENTRY 32 TOTAL AREA 2276 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONIC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION jR-11/R-13 (GARAGE / LIVING) KRAFT FACED 0l2 M O _ Q u-� a--� w M d �U — O LU Ln �- o Lo ch F .� o o cor` U LU N t`N7 s — E — 0 m a th O o 0 Qj t U. 00 00 0 CD Y CL LIDO � <C rn rnQ o A 0 t;CB DC \•�cv°.e , c?n� LLJ" o �.W d LP lRS �.aLL 0 C N �Z•Q�f��o � 8 �g •a =' W Nod To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N r- Q ate.+ O i>i M O M QUO' a`f' a L Ln lj Q(1)- Ln U 00 Q Z J W � oZ = O 5 WLij za z� aQ bawx 00 Z , W = a w Z J O � LPL N W ow o Ln Cr zz >- o ¢z 0 zW O5 �� >_ LL- �o O > rl o 0 v inLu T J X U. U U� n a fV A 1` z R< LUp LU Q Q Q Q Z N Wo,-2 W Ln ,—� w a0= o o LU Quo w M M Q z Z Ce <1z *k a Z z o o N.g LU az rn SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION N0. 10 SHEET NO. 1.0 I - I I - ',1 -, __ - -_ I - r 0 MIRROR 0 OWNER'S BATH O iv KITCHEN ISLAND W 0 F- 0 M nF11 F1- Ll I Ll LL11 i FCj I I BATH 2 LJ LA HOOD KITCHEN Lill G M G M CV iV OPT. REF. Ll KITCHEN INTERIOR ELEVATIONS SCALE: 1 /2"=V-0" (D 0 O _ CD z d t2 IC� O I ^ II l.J (v W C ) '('' J Lu Ow O 0 c,n � o 0 mN U W a) C co Cl)0— E — N O coN 0 0o N = LL 00 O 03 00 I' Lv Y U) 0 Q °a) rn Q 0 AlNC9D.0 B D® °e . OR�gi 6 LO Aw i.1.1 wtR o' V H`l� 04 miu Z ,d �V♦ N M G To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z cV O N r-. > O < M Ln a v Nt o Q aLL H Ufu aOC) Q ... E Z � � W O W JC) oZ za f F � �z00 o � w =QWz U J J o�2o V w N W Fw0 0 � W Q ZO Q z g g O v\mil L ,/ALn 0 JJ 0 O J Q . ^ U) UJ Q zo 0 -j cV ou wu.m� O [V z2!0 Qz Q �} V N H� � N Z w fV w a w woz Lr) w = Q LL : o 0 Q W i5 M M Q Z <�_ d'tu—z V) o J LU a w ,--i a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION No' 10 SHEET NO. 2.0 " 4" THICK 6" NOTE: • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH • FOAM / EPS MATERIAL IS ACCEPTED � BRACKET DETAIL 12 5� 16'-0" RIDGE VENT 12 �5 3'-0" RIDGE VENT 12 �5 FRONT ELEVATION - A LEFT ELEVATION - A General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1 /300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. -CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA! FT. " (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. "Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SQ, IN. OF NET FREE AREA / VENT "Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed)186.25 = Amount of O'Hagin Vents Needed 0 0 Q Z —; CL +-J LL, 'u - OL L)of E 0 M v I O 0 M/� O✓ m04 a)M W O - U C� M Cl) W 6 co O O0 ai ,.. inn •t�' � �, � � =FL00 O Y � o o CL 0 LO °o Q a� rn Q o A1 NCBDC ID ° + '�• C14 co r� Z ti O ~0 zu ro IL W1'5 L5 o � Q .�r8 P/4f In",1110 ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z N O N t/Ln —I M CD a�ru U') z CL .L V) 0 Q Ln ` n Q U a� ra z W J�~ J oZ W� z< a f a-�a 0 0 Z O z z td W Cr o w z a On8 w w LU �Wo oN J LU z0 Q U LL) z z 5 O Q n3 fu > rl S 0 z v i aJ W Ow zo Q O F¢¢ JJ O T. J O O 2 O U V m 5 (V Za0c, LL wLuZ� a How Z Z N 17 0�og a4 W J L r) r-I LLI Q lJ J Q Z Q o w o Y Q c cc 0 M M z < z V) z m g = J R az ,--I SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION N0. 10 0 SHEET NO. 3.1 12 5� 12 �5 — — — T.O.M. 1'-O" — -- ---- HDRHGT. EXTENDED OVERHANG TO BE CENTERED ON DOOR 12 3'-0" RIDGE VENT 5� 12 5 16-0" RIDGE VENT ----------------------------------------------------------------------- TEXTURED CEMENTICIOUS 00 00 FINISH ON C.M.U. io (TYP. ) 12 �5 ------------------------ --- — — -- 1'-0" TEXTURED CEMENTICIOUS FINISH ON C.M.U. (TYP.) 35 SH F.FL. REAR ELEVATION - A SCALE: 1 /4"=V-0" RIGHT ELEVATION - A General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. "CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - (Values to be verified with Manufacturer Specificatlons) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. " (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 172 = Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. "Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT "Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed CD!;2 Z o z � o� 0. O cry � LLI �U — 0 LU 0:: f ^ ::D F- E o M v J O a tJ.J c: co M r E ® U ca-am O O C:) T ai w LL co a) d 0 0 QO u7 ov 0) AI B we NCBDC All `ate • • YI �•d � uov app,� �~o s,�: J � "O Lem r9.1 N '\ LLI UI .J.-r- LLB. O Yr L& o Co r- o ! C N co c1b 41iZ R40 9ESS� �S j////' 11111111100 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z (V O aJ t—+ a_' O �>-+Up) MO M Q V �_ Ln L N Q LL a e -'s I— . Q U Q� WJ O d' 0, O w � zaa C }� Za&� opw,w _O z U z Q = p= U,Z r�y2z W / Y a 2 ' '8 LU LU M�o J W zZ >o ¢z LUz 5 z :D -0 fa U va3 � Q ULU Q� 0 a (11 0 LL1 o a a rq Zao Lu Q Xo Z LU N Lr)rl LLq$Jo o Q U o z = IJ.J Q o Z o LL Q M M Q Z W ¢�z a Ln O d- Q J = z Ln az r, r-I a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION No' ^ . 0 SHEET NO. 3.2 ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. POWER CO. INTERSY: BON TERMINATIOI` NEC 08, 250.94 J 200A INDOOR PANEL CENTER CLAMP PER 250.50 AND 2%52 OF THE 2011 NEC. upper to lights & outlets upper to 20 amp ckts copper to W H copper to Dryer 2 Alu GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. 1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. ELECTRICAL KEY ] DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER �IQW.P. WEATHERPROOF DUPLEX OUTLET GROUND FAULT INTERRUPTER DUPLEX OUTLET G.F.I. HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET $ WALL SWITCH $3 THREE-WAY SWITCH 4 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE ORECESSED LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN P.C. TRACK LIGHT FLOURESCENT LIGHT FIXTURE O EXHAUST FAN ;O EXHAUST FAN/LIGHT COMBINATION ®D ELECTRIC DOOR OPERATOR (OPTIONAL) CH CHIMES (OPTIONAL) El PUSHBUTTON SWITCH (OPTIONAL) SD SMOKE DETECTOR CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) ❑TV TELEVISION (OPTIONAL) ©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. O THERMOSTAT �N ELECTRIC METER ELECTRIC PANEL DISCONNECT SWITCH SPEAKER (OPTIONAL) ROUGH -IN FOR OPT. CEILING FAN v J CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR G J OPT. CEILING FAN G�) (1) PHONE LINE, (1) DATA PORT H.B. VERIFY METER LOCATION WITH BUILDER MAIN FLOOR ELECTRICAL PLANT SCALE: %4"=V-0" M 0 aW O O Q) cn O LU r.. I, E O CO i� � t-- O J iiJ N Cl) CM M �- E _ OU m -o M O CD AN t U. 00 LO O V 0 k A � B D. N C B D C N to to N o N oCi N " Z W` "'"N r r1 M Ot c ~O N_ r17 z co z J V_ N O w ) W M M N LL V\ y LU IZ w Z O m o Q y.�oq)o LL ZN� -ca 0 0 mm a� W a ° ¢ J o 0 N M � b U � U ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N O 11 4-JO r>-I M O Q Ln Qv LL I_n U Q 00 Z a �0 Z ra Z WJ C:) J oZ �o w� Z as f Z Q r~ �uQzra zoo J ZUZ< =owz J �°mow U OU N co mZo �W oZ Z Z ,--1 L r- U >U Q Z Fw Z s W S 0 Z U O LL J �E oLL a,0 p �' 1 (V` 08 N Q a a oaoa Z C C 0 J W Z Q Q �fo Z w Ln aWoZ J rl W Q LLJ Q Z o 0 Y Q Q C Z M M '""4 Z a U) O Q J = J 2Z aZ n r-1 a- (n SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION N0. 10 O SHEET NO. 4.0 VENTED SOFFIT 46 SQ. FT. VENTED SOFFIT 46 SQ. FT. ti% fa ZONE-1 ATTIC SPACE :12 SLOPE 2276 SQ. FT. 177771 O J N_ 4'-0' ROOF VENT ; RnGF 16-0' RIDGE VENT 4'-0' ROOF VENT 1AQ i f'-0' RIDGE VENT �•� RIDGE 5:12 SLOP [ Lu a. 7. lr9 N �: 5:12� ATTIC VENTILATION CALCULATIONS ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED 1/150 Rule 1/300 Rule Ridge Off -Ridge (No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. Req.) (Ft) Total Ventilation ATTIC Provided SPACE SQFT Total SQ. SQ. FT. SQ. IN. of by Upper . . SQ. IN. of of vented IN. of of ventilation to SQ. IN. of SQ. IN. of Ventilators I, ventilation soffit ventilation vented be provided Ventilation Ventilation (See Elev ) required needed required soffit by upper needed ventilators Main 20.00000 2.000000 Floor 2276 2185 312 1092 78 546 0 576.0 300.0 276.0 (Zone 1) **NOTE** GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS REQUIRED BY FBC 5th ED. RESIDENTIAL. VENTED SOFFIT LEGEND IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED E= AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. VENTED SOFFIT VENTED SOFFIT 66 SQ. FT. CRICKET.. a :::::::: .. ... .•O .ILJJP :I r0 Lb f) GE 5:12SLOP ti% ................................................•............................................................................................:fi.'.............................................................................................:�'.... VENTED SOFFIT 62 SQ. FT. 1' ROOF PLAN SCALE: %4"=1'-0" General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. **CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. ** (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roof) - 9 SQ, IN. OF NET FREE AREA / FT. Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT '"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 66.25 = Amount of O'Hagin Vents Needed co 0 0 a. C Z r./) O LU 1- 0 vi 0 0 \1 N M cr M co ,. E o fD a M O ° o a) L LL CC) -- } r Y °ol un 0 V rn Q 0 A 0 vCBoC Wlp /Lys A— : EN ,.__ W Q N M N P. m lozocW —>0. Lid .� o a Z E °' I I � Iti UM r s. W NQN, o °ra1't11t� o To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N 0(3)� 1--L +_' C:) CD L/-L J) M -fu L(1 fu a U L I— C)- , M QU ro Q� z�ru WJ C:) 0, F0 35 cL p z d f a Va�o: 00 Z O U U 0 Z z Q Ci0JZ W m Z O 0� Z Z ro aZ } 5� p -0 4 ro F_ O L > r� ZQ 8 o U i2 0 T-091 O U&m —'< 0 0 WL�_ a' Z Q a Z N au-o WLr) 00Q-0 J IJJ 0zU ('n M � Q Q Z Q W r- C2 0 1Ij adz a V) m V Z 1�1 W J 0 aZ O g = z rn ,—I a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION N0. L^ . O SHEET NO. 5.0 T I —TT_I FT III T_I c c v 37'-811 7'_ 5'-211 51-1 II 6 4" 10 5--0" 3'-0" TYP A L S3 H g + S3 2'-6" x 2'-6" x 1'-0" W/ (3) #5'S E.W. 04 r INDICATES FILLED CELL w/ 3000 PROVIDE %" x 9" iv o r PSI CONC. GROUT FROM FT. TO : BEAM W/ #5 REBAR RECESS FOR FRT. DOOR 31/2" SLOPE - io ;n STEPS AS (1) VERT U1 TOP OF CONC./ PAVER TO BE 4" ----� I 10 REQUIRED I ABOVE SLAB TYP @ ALL 0 0 I PLACES SHOWN HOOKED FTG. is BELOW FIN. FLR. _I 2'-0" 4'-0" 2'-0" 6'-0" 1'-101, 5'-2" I I �. PER FIELDI CONDITIONS DOWELS 5" EMBED W/ 25" EXT. ; C 1 ABOVE SLAB GRADE 40 STEEL' CJ CJ ..... — ; ■ N� ■ ■ ■ ■ ■ _. I— TYP PROVIDE 1 Y2" RECESS FOR SGD. REFER TO HVAC CHASE 1 AHU I; _ 00 o L S3 MASON'S SLOPE FOR �, I WIDTH LO BASED ON LOCATION •. / I . Ln in I I / I i•� �• (2) #5 REBAR �3 1/2" 32'-84" `� - 4'-88" ' ' VERTICALS w/ in I L_ FILLED CELL I — — s a 37'-5$" 2 V-28' 6-4" X-8" 7-811 1 2'-1" 31/2" 4'-0" I G SLOPE Ln S3 II CJ — — — — — —I CJ CJ i --�— — — — —r� - — — — --__} — — — _I 1j 1 ---- --- 1 ��� t4 :: _ . I CJ I _ — — — — — I I _� _�.� _ _ o o N ASE i KITCHEN ISLAN , CH ISLAND 2'-6"x2'-6"x1'-0" LOW WALLS I l �D a r-• I1 J I i S3 p W = a t W/ 3-#5 E.W. CJ L.� _ _ - - - - - - bN G SINKw/DISP r ) j K ih S3 : N 1 } O S3 I o 23'-11" 2'-10" 41.1411 } I: 11811 `n t}t I(2) #5 REBAR q S3 : �cj �Cj } K VERTICALS w/ in ) j I ' S3 FILLED CELL N I CJ T T rI : ...................... o0 a 1} 1.........I: ...: ::.......:.. ._:___._.�............. : :::: ■ — 01-01, PN OCP 00 ( : ■ Cl) 13'-7--2" G'] CJ CJ ■ : ici CJ ... : %: ...... :... — — — —�� — — I— — - — I—� — — — — — — — — 0? Cl) ,-ter, 3-1/2" MIN 2500 PSI CONC 0'-0" SLAB OVER 6 MIL VfSQUEEN VAPOR BARRIER I : ■ CP / .......:::: a �� (3000 PSI CONIC. SLAB FOR 1 I i Li IL HERNANDO COUNTY ONLY) I °' I � .. ........................... H.B A 7-2" 5'-2" 6-0" 6'-0" T-O" 3'-10" 4'-0" 3'-10" 4'-8" 4'4" L 5'-2" L 5'-10" FOUNDATION PLAN NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "E" OF THE FBC 5th EDITION (2014) BUILDING IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL 8 TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING W.W.M. PLACED IN 1/8" SAWCUT x 114 SLAB UPPER 1/3 OF SLAB THICKNESS WHERE OR FIBERMESH SHOWN ON REINF. SEE PLAN. FOUNDATION PLAN Lux LU g N CONTROL JOINT DETAIL SCALE:1 117=1'-0" #5 CONT REINF. SEE • " FND. FOR QUANTITY ',; ' ;•; #5 X 25" X 25" CORNER �' '� ; :' '•_; ; ; '•- BAR ONE FOR EA. ' ' HORIZ. REBAR, TYP. �., • U.N.O. ' "Alternate: _ _ ,; • :r,; :; :;;,:::;;,: :; :;; The reinf. bars shall be cont. around comer by cold • ,:• • ,; • bending the bar w/ min. bar lap of 25". TYP. CORNER BAR DTL. SCALE: 1 1 /2"=V-0" Z M O Z �O � Z `d ; �. J Z O W cn i--� w "U — 0 LU N 1— E 0 00 m r` U LL g N c) G) co M F- E —0 w •o M O`oo N L LL 00 0 Y n U5 <C 0) M<0 a a I CBoC B D• •� 0. ° �i,Ku, n ^� N F czl �- o�.J- N Z o'F�}� :�C9.. S-t' �', Imo- LL•Jis► -j(D /�/y.... �•` 4 N M0 ,� I l Q CL-u- O r CL Luz , Z O c (1)v (��°�• m 2 c "o� n m .� U0 LU '�`�fU!1114fi��� ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O r4 Z � 1- > (n M 00 Q u Ln 0 ui ',= d- a(ULL '� ..•. Q U a 00 .� Z W J oZ 3Lr) �o z a Z� aQ f F z w Q o �Z08O Q J ?Uz¢ � �OWZ W WJ z O Ce o w 0 FWo oN Zz ¢o Z f z � z 43: fa Z S >O o Q J U cn 0 z 0 W o o o N �: wood U�p]� fV ZLum l z J Q Q N Q 10, �o Z Z LU fV Ln LLI Qao� Q J �.{di Q Z owo ~ MIZ M z a m 2 Qo 0 LU .-I a to SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION N0. 200 SHEET NO. 6.0 I 1 11 11 - I - - I I If- - - - - UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. O CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 - 10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA16 1615 1585 10 - 10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8 - 8d RT3 610 525 8 - 8d X 1 1/2" E META20 1450 7 - 10d x 1 1/2" HTA20-18 1400 1400 10 - 10d X 1 1/2" F HHETA20 2235 10 - 10d x 1 1/2" G H10A 1340 1015 18 - 10d x 1 1/2" RT16A 1380 1160 9-10d X 1 1/2% 8-10d H HTT4 3610 3105 5/8" ANCH. / 18 10dx1-1/2 HTT4 2715 5/8" ANCH. /(20)10dx1-1/2 J HTT5 4350 37140 5/8" ANCH. / 26 10dx1-1/2" HTT5 3225 5/8" ANCH. /(28)10dx1-1/2 K HD3B * 313 0 0 5/8" DIA. BOLTS TDX2-TZ 2345 — 2 - 5/8" DIA. BOLTS L HD5B * 4505 3785 5/8" ANCH. 3/4" STUD BOLTS TDX6 5320 — 2 - 7/8" DIA. BOLTS M HD713 * 6645 5650 7/8" ANCH. 3/4" STUD BOLTS TDX10 7845 — 4 - 7/8" DIA. BOLTS N LUS26 1165/1070 ** 1005/915 ** 8 - 10d x 3" JUS26 1115/1060** — 8 - 10d P HUS26 1550/3335 ** 1335/2820 ** 20 - 16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" Q HUS28 2000/4220 ** 1720/3125 ** 30 - 16d x 3 1/2" HUS28 2570/4345 — 30d -16d x 3-1/2" R MTS12 1000 860 14 - 10d x 1 1/2" MTW12 1195 1 005 14-10d x 1-1/2" S MTS16 1000 860 14 - 10d x 1 1/2" MTW16 1195 1005 14-10d x 1-1/2" T MTS20 1000 860 14 - 10d x 1 1/2" MTW20 1195 1005 14-10d x 1-1/2" U MGT/MUGT 3140 3140 22 - 10d X 1 5/8" ATR W/ 5" EMBED W/ SIMPSON "SET" EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4" x 2-1/4" TITENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4" x 3" WEDGE BOLTS 11X1. HTS 20 1450 1245 24-10d X 1 1/2" HTW20 1530 1285 24-10d X 1 1/2" SP1 585 535 10 -10d SPT22 685 8- 10d SP2 1065 605 12 - 10d SPT24 1030 12 - 10d HCP2 645 555 12-10d X 1 1/2" * MINIMUM 3" MEMBER ** REACTIONS ARE FOR ROOF LOADS ONLY *** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3112 & LOWER. LOADS - ROOF = L 1360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS (B) B) (A) (+ 1 OR 2 PLY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") 'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW, FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). (B INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 1 fly STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 'rW1 OR CONY LEDGER .�A) INTERSECTIONS. SPLICING TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 5-0" ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. ROOF FRAMING PLAN a (r) L0 e% M o _ C car. 0 V) (-D a--� U, *U — O V) ~ 0 In r� VIMv, 0 0 mr- L1J a� C� (6 M F- O ® 0 (6 '0 (1) O 0O NO a i �p LL 00 0 ai a o O m V rn Q 0 A 0 B D® i q¢Ef R ,EFc,, ' Z ` (7- W13, O`co -+ N ti t , LU , Or, ° o ti C N 0 x Z N i E o a aN�_ W N 10 0 El 1:1 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 Z N O a� M O I> -I Q U a � L L- Q LL- d e-'s M U Q 00 z a 7ri z WJ CD 0Z 0 > w< Za aQ > Z LL1 0- U a p o Zv0 Qx J M0Zz 0 a 0 O W _Z II--WQ 0 Z Z > 0 a Z f o 5 Z -a O U- ` 0 0 i N 1 ,-I 0 O 0 J a V (n —1 LL- W x 'o9 LL— Z O N 0 O 0 wood U as a N o¢oa ?¢ Icy-Q �' ~ C) Z N w>o Z � Q Q Z o W o W�e < <,z M M tu— _¢ aZ m ^ g = z a° O SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION N0. 10 O SHEET NO. 7.0 i GENERAL INSTALLATION NOTES 1. Provide full mortar head and bed joints. I 2. Shore filled lintels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate i vertical cell reinforcing and grouting. 5. All lintels meet or exceed U360 vertical deflection, except lintels 174" and longer with a nominal height of 8" meet or exceed U180. 6. Bottom field added rebar to be located at the bottom of the lintel cavity. 7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. i i 8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete masonry units. 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. 11. The exterior surface of lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with verttcal (gravity and uplift) and horizontal (lateral) i loads shoud be checked for combine loading with the following equation: i Applied vertical load Applied horizontal load . 0 i Safe vertical load + Safe horizontal load GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY TYPE DESIGNATION F = FILLED WITH GROUT / U = UNFILLED R = RECESSED QTY. OF #5 REBAR @ BOTTOM OF LINTEL CAVITY = �w w 81-16- B/1T ¢ z 0 Z tNOMINAL. QUANTITY OF WIDTH #5 REBAR AT TOP NOMINAL- ° HEIGHT mom #5 BAR .(1)RE TTOP ALTERNATE POWERS MIN. (1) REQ'D CLEAR STEEL LINTEL d d a ° .M.U. #5 REBAR AT TOP d ° d MIN. (1) REQ'D °' 1-1/2" CLEAR ° p ° dd d ° GROUT �o d 5 REBAR AT uJ ¢ ¢ = w ° O BOTTOM OF a N r Or LINTEL CAVITY y wo U OTTOM E w .>< Z 7-5/8"ACTUAL REINFORCING PROVIDED IN < ¢ (7 m CZ, o w 0 JOMINAL WIDTH LINTEL ¢ _' W 3 N IR (VARIES) in B ¢ 00 . `:' MATERIALS cc pr�ntels = 3500 psi. 2. fc prestressed lintels = 6000 psi. 3. grouted per ASTM C476 fg = 3000 psi w/ 4. maximum 3/8" aggregate and 8" to 11" slump. 5. Concrete masonry units (CMU) per ASTM C90 w/ minimum net area compressive strength = 1900 psi. 6. Reber per ASTM A615 Grade 60. Prestressing strand per ASTM A416 grade 7. 270 low relaxation. 7/32 wire per ASTM A510. 8. Mortar per ASTM C270 type M or S. LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) D ° Q C.M.U. ' a - D D 5 REBAR AT BOTTON ° Q AS INDICATED ° Q ° 16 GAUGE POWERS STEEL BOXED LINTEL POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF NOTED ON LINTEL PLAN 1. Refer to manufacturer's specifications for installation. 2. Contractor to provide proper protection of lintel to prevent rusting Refer to manufacturer's specifications. 3. If lintel is scratched or damaged refer to Powers Steel for repair. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel plan/details for bottom steel required. 5. A bonding agent must be applied to the Steel Box lintels prior to applying the cementitiuos coating. See contractor specifications U UB 6-10" LL 6-6" LL O O 4'-6" LL 4'-6" LL O MIN. 17'-4" LL O 6-10" LL LINTEL PLANT SCALE: %4"=1'-0" I CD N z M 0 O -- o CD r1 U) O Ln CD n W C 4--J Lu r� VOLLJ CW Ln � E 0 r ^ N �p V 1 O �� vv U W N M — E �- U m-orM) O o0 = d) UCU m L_ LL 00 Y Q C u7 O � OI m Q O A N C B n C e�' 44; tip IIAJ C�`� LL�' cqt0 .� A ?� Al 2 ,Z To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N O a) r- h--1 4-J C:) CD Mrn O a U') (V_ Liz d V) n Q U_ oC U ra 00 fo Z J C) W Lu C:) oZ ff O � o W Za Z� ¢Q �ao� U ? U U Z U ¢ p W Z "� (Y o J 2 O O K w Co z0 00N Zz r� J T ¢z f Z Z -0 7 , 5 va3 �— o T—I o 0 0 cn o.. J W < 9 OW o 0��� 0 wo�oO� cg� J Z LLQLLJJ Q u, 2'�J Z ¢ �/ ILL Q V gi O Z W Nao LIi w Q Q Z �Qpe� r o 0 W Q se ¢ ~ <LU Z M M Z L aZ z m = a o .—i 0- U0 SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION N0. 10 SHEET NO. 8.0 --------1 NOTE: BORATE APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2 PRESSURE TREATED LUMBER THAT HAS BE CUT OR DRILLED T ) BEEN THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE (CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS SU 00 S THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS (RE: FRC R308.4) R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY II AS INDICATED IN TABLE R308.3 EXCEPTIONS: 1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5, GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR. 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM ) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7, 3. GLAZING IN SECTION R308.4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 4. GLAZING IN SECTION R 308.4, ITEM 6, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION OR WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 7. 5, GLAZING IN SECTION R308.4, ITEMS 7 AND 10, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES 12 INCHES (9141 MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 %2 INCHES (38 MM) IN HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL [WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR. 7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308.2. 8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 9. SAFETY GLAZING IN SECTION R308.4, ITEMS 10 AND 11 IS NOT REQUIRED WHERE: 9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF SECTION 1012 AND 1607.7 OF THE FLORIDA BUILDING CODE, BUILDING; AND 9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. 1. SPECIFICATIONS 1.1. CONSTRUCTION: 1. 1. 1. ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.1.2. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1-11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1. 1. 3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1. 1. 5. FLORIDA RESIDENTIAL CODE (FRC), FLORIDA BUILDING CODE (FBC) 5th ed. (2014) 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC) 13TH EDITION. 1. 1. 7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TRI1-02. 1.2. DESIGN: 1.2.1. ACI 301-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-11, ASCE 5TTMS 402-11 & ACI 530.1-11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1. 2. 6. FLORIDA BUILDING CODE (FBC) 5th ad. (2014) AND FLORIDA BUILDING CODE 5th ed. RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS: 1.3.1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 1.3.2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA. REG. PE. AND SHALL INCLUDE: DRAWINGS AND CALCULATION REACTIONS AND S BEARING POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS: 2. 1. 1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 2.1.2. UNIT WEIGHT OF REINFORCED CONCRETE: 150 PCF 2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: 55 PSF 2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2. 1, 6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2.1.7. BALCONIES & DECKS: 15 PSF 2. 1.8. TILE ROOF TOP CHORD : 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOP CHORD : 7 PSF BOTTOM CHORD: 10 PSF 2. 1. 10. FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1. SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2. GARAGE LOADS : 40 PSF 2.2.3. PARTITIONED ROOMS: 40 PSF 2.2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS: 40 PSF 2.2.6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2. 8. ROOF TRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE) : 10 PSF (NON -CONCURRENT) BOTTOM CHORD (ATTIC W/ LIMITED STORAGE) : 20 PSF 2.3_ RAILING LOADS: 2. 3, 1. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SQ. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3.1., 2.3.2 & 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FBC 5th ed. (2014), AND CONDUCTED BASED ON A 140 MPH 3 SECOND GUST, EXPOSURE "C", IMPORTANCE FACTOR "I" = 1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS -10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE 7-10 2. 5, DEFLECTIONS: 2.6. 1, FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240 TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1. LOAD FACTOR DESIGN: THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2• SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DL + FLOOR LL + ROOF LL TOTAL DL + FLOOR LL + WL TOTAL DL + WL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. 3.4. DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS. 4• MATERIALS 4.1. REINFORCING STEEL: 4. 1. 1. REINFORCING STEEL SHALL BE ASTM A615 / A185M-04A MIN. GRADE 40, fy = 40 Ksi 4. 1. 2• LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4.1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4. 1. 5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4.1.6. DESIGN COVER REQUIREMENTS: C-I-P CONCRETE FORMED AGAINST EARTH: 3" C-I-P CONCRETE EXPOSED TO EXTERIOR: 2„ C-I-P CONCRETE NOT EXPOSED: 1 /„ GROUT FILLED MASONRY: 1 4,1.7. WELDED WIRE FABRIC (WWF): ASTM A-185 / A 185M-07 4. 1. 8. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-11 (STRUCTURAL CONCRETE) ACI 530-11 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1. CONCRETE TYPE MIN, 28 DAY DESIGN (fc) MODULES OF ELASTICITY DESIGN (E) C-I-P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-I-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ksi C-I-P GROUT 3,000 Psi 3,122 Ksi 4.2.2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS) : 3 1/2" MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.2.7. CONCRETE PLACEMENT PRACTICES SHALL BE IN ACCORDANCE W/ ALL ACI- MCP 2011 STANDARDS. 4.3. CONCRETE MASONRY: 4. 3. 1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-0601, TYPE II NON -MOISTURE CONTROLLED. 4.3.3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL STEM WALLS. 4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 PSI MINIMUM. 4. 3. 5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.16. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. 4.4. STRUCTURAL LUMBER: 4.4. 1.1. INTERIOR LOAD BEARING WALLS SPF #2, fb = 1,312 PSI, E = 1,400 KSI ALL EXTERIOR FRAMING SPF #2, fb = 1,312 PSI, E = 1,400 KSI 4.4. 1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4.4.2. I PP ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15/32" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. 4.4.3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES. 4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4.6. WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSI/TPI 1-2007, BCSI 4,4.8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8" STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK 4. 4, 10, INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R706.6.1 4.5. FASTENERS AND TIE DOWNS: 4.5. 1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTM A36/36M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTM A307 4.5.2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33KsiWITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. 4.5.3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0.131", 10d = 0.148", 12d = 0.148", 16d = 0.162". 4.5.4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION. 4.5.5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4. 5. 6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4. 5. 7. CONCRETE EMBEDDED'S BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. 4.5.8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.6. MICRO -LAM LUMBER: 4.6.1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E = 2,000,000 PSI Fb = 2,950 PSI Ft = 1,850PSI Fc = 500 PSI (PERPENDICULAR) Fc = 2,700 (PARALLEL) 4.7. STEEL: Fv= 285PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEEL ERECTOR. 4. 7. 2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4. 7. 3. STRUCTURAL STEEL: ASTM A36/36M 05. 4.7.4. STEEL TUBING: ASTM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3/16", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN, 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL: ELEMENTS ARE IN PLACE. 4.8.1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF 4.8.2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FBC 5th ed. (2014), RESIDENTIAL SECTION R318, 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02E01 TERMITE PROTECTION - CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate / Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1. FRC R318.1- "A permanent sign which identifies the termite treatment provider and need for re -inspection and -treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel" 2. Condensate and roof downspouts shall discharge at least V-0" away from the building side walls. 3. Irrigation/s rinkler systems including all risers and spray heads shall not be installed within V-0" of the building side wall. 4. FRC R318.7- To provide for inspection for termite infestation, between wall covering and final earth grade shall not be less than 6 inches. Exception: Paint or decorative cementitious finish less than 5/8" thick adhered directly to the foundation wall. 5. FRC R318.1.1 - Initial treatment shall be done after all excavation and backfill is complete. 6. FRC R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FRC R318.1.3 - Boxed areas in concrete floors for subsequent installation of traps etc„ shall be made with permanent metal or plastic forms. Permanent forms must be of a size and depth that will eliminate the disturbance of soil after the initial treatment. 8. FRC R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilution. If rainfall occurs before vapor retarder placement, retreatment Is required. 9. FRC R318.1.5 - C n rete over our Ind mortar along the foundation perimeter �ia must be removed ore exteror sotreatment. 10. FRC R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0" of the structure sidewalls. 11. FRC R318.1.6 - An exterior vertical chemical barrier must be installed after construction is complete, including landscaping and irrigation. Any soil disturbed after the vertical barrier is applied, shall be retreated, 12. FRC R318.1 - All buildings are required to have pre -construction treatment. 13. FRC R318.1 - A certificate of compliance must be issued to the building department by a licensed pest control company before a certificate of occupancy will be issued. The certificate of compliance shall state: 'The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FRC R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-0" of the building. This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. WORST CASE DESIGN PRESSURE TABLE BUILDING DATA WIND SPEED (ULTIMATE) 140 MPH WIND SPEED (ALLOWABLE) 108 MPH WIND EXPOSURE -- "C" (FRC R301) INTERNAL PRESSURE COEFFICIENT= 0.18 ENCLOSED BLDG) BUILDING CATEGORY = II DESIGN WIND PRESSURE: (COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) # END ZONE IS ONLY WITHIN 5-0" OF ALL EXTERIOR BUILDING CORNERS WINDOWS AND DOORS 140 MPH + 29.7 PSF / -39.6 PSF (END) U.N.O. CONSTRUCTION + 29.7 PSF / -32.2 PSF (INTERIOR) U.N.O. TYPE: 5B GARAGE DOORS (V = 140 MPH) SINGLE 90 +26.3 PSF / -29.8 PSF DOUBLE 160 +25.2 PSF / -28.1 PSF NOTE: THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES. NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1 4" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1%" DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBAORD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW / NAIL DISTANCEFROM EDGE SHALL BE Y8". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. (O a Li Z C-n � a 'u - 0 E 0 a o m� 0 N C, LU Eo o c' m m O 0 o a L LL � _ a � � W 1 N ao O a �m mao A � "cant, C 0 rn If-N U^y; O{Y.oN Z"• o I LAI M Gi ` x . J f' w. cr r, a `V ) ZY3, O,• ,0 Qsy • ' - ��f� E L z ¢. �^ n N y= W :� . - '0 0 U' U � ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N O a� > (1)M O Q d Ln i L!') Q LL U Q � � E Z WJ C) J oZ �o �o w Z Qa <¢ WQz° U Z o oO M z0WU ��wz w Q o LL U^ vJ U w N mz0 W on }o rl 0 Q U �Z g Z -0 z 3 :D t,3 Q O G \ O ¢ U F_ ::D 9 o" ZO < o r- 0 ,'-1 o V � m a 22c a N U) oQoa Z W Z J Lua< tY � ow F E o Q CV 4g Z Z woo oz W J Ln �r W 0<c" (6 OU y-,di a O Y a M M Q Z~° a�Z a Ln Z o g = J o aZ n 0- U) SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION No' 10 O SHEET NO. SN CORNER OF HOME GARAGE SIDE ROOF DIAPHRAGM NAILING SCHEDULE RIDGE LINE v,+ + + 4 + + + + + + + + + + + + + + + + + +++++++++ + + +f-+++ w 15/32" CDX a PLYWOOD OR 7/16" OSB RIDGE LINE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & + + + 1 + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER 16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH 0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER 2 INCH NAIL LENGTH 2 INCH NAIL LENGTH NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL 'GUN NAILS MAY BE USED 1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. 2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. 3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSIST S OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 6'-0" + + + + + 6'-0" 1 + + + + + + +++ +++ ++ +++ ++++++++ + Backer and Filler Block Dimensions BCI®Joist Backer Block Series Thickness Filler Block Thickness 3/4" 5000s 1.8/1.7 p nel wood panels Two 3/4" wood panels or 2 x 1-1/8" or two 1/2" 6000s 1.8/1.7 wood panels 2 x _ + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 6500s 1.811.7 wood panels 2 x — + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 602.0 wood panels 2 x _ + 5/8" or 3/4" wood panel 90 2.0 2x _ lumber Double 2 x — lumber DOUBLE JOIST CONSTRUCTION (Not required if both loaded equally from above) ° Filler blocking x 1/8" gap FILL CELL STD. 900 HOOK BOND BEAM v7 uu cr STD.90° CONT. #5 CONT. #5 HOOK BAR BAR #5 CONT. .... FROM FOUNDATION TO HIGHEST --��— ���� BOND BEAM BOND BEAM STEP SCALE: N.T.S. 2nd FLOOR INTERIOR/EXT WALL SEE PLAN FOR MORE INFO CONT. BASE PLATE BEARING COLUMN SEE PLAN FOR REQ'D ��PLYWOOD FLOOR COLUMN AND / SHEATHING PER PLAN CONNECTION TJI TO BE CUT TO ALLOW FOR BLOCKING/TJI MASONRY WALL OR INTERIOR BRG. WALL TJI PER PLAN OTHERWISE SOLID BLOCKING TO MATCH Solid block all posts from # OF 2nd FLOOR above to bearing below. STUDS SECTION @ INT. BRIG. WALL N.T.S. 1/8" min. ) Small gap 2" min. 2" max. 4" max. -V Clinch nails when possible 1) Support back of web during nailing to prevent damage to web -flange connection. 2) Block solid between joists for full length of span. Tight fit 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/P►ywood/OSB web stiffener - �" min. Web Stiffener Fastener Schedule Joist Bearin Location Series Depth End Intermediate ®i 9-1/2" BCI 5000s ' 11-7/8" 14" 2-8d 2-8d 2-8d 3-8d 2-8d 5 8d 9-1/2" BCI 6000s®111-7/8" BCI 6500s®'~ 14" 16" 2-8d 2-8d 2-8d 3-8d 2-8d 5-8d 2-8d 6-8d 11-7/8" BCI 60s® ''^ 14"__ 16" 2-8d 3-8d 2-8d 54cl _ 2-8d 6-8d BCI 90s® 11-7/8" 3-16d 3-16d 14" 5-16d 5-16d 16" 6-16d 6-16d required when indicated or max. 2x-: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. OF THE JOIST ASA REQUIRED LEAVING %$' GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER top flange of joist. DOUBLE JOIST CONNECTION -Birdsmouthcuts. N.T.S. - Under 2nd floor column w/ loads N.T.S. SQUASH BLOCKS AT INTERIOR BEARING Vertical load transfer =1900 plf max along load bearing wall. Load bearing wall must stack over squash=20 blocks and Non -stacking walls require additional wall or beam below.* consideration. Check local building code for appropriate 1/16 details in One 10d box areas=20 of high or-20 sinker lateral load. nail each side 10'-0" at bearing. TANK -LESS W/H H C G 00 O 5'-0" - STUB -OUT FOR 0 9 LID GAS METER O o � U I iV = • MEASUREMENTS ARE FROM FINISHED FLOOR • ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER • ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER GAS CONNECTION DETAIL **ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4" @ 16" O.C. T-5" (2) 16d TOENAILS 2" X 6" @ 16" O.C. 10'-8" (2) 16d TOENAILS 2" X 8" @ 16" O.C. 13'-9" (3)16d TOENAILS 2" X 10" @ 16" O.C. 16'-5" (1) USP HTW20 OR (3) 16d TOENAILS 2" X 12" @ 16" O.C. 19'-3" (1) USP HTW20 OR (4) 16d TOENAILS 2" X 4" @ 24" O.C. 6'-1" (2) 16d TOENAILS 2" X 6" @ 24" O.C. 8'-6" (2) 16d TOENAILS 2" X 8" @ 24" O.0 . 11'-0" (2) 16d TOENAILS 2" X 10" @ 24" O.C. 13'-0" (3) 16d TOENAILS 2" X 12" @ 24" O.C. 15' 4" (1) USP HTW20 OR (3) 16d TOENAILS * TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). ** SOUTHERN YELLOW PINE, 55 PSF LOADING Squash block (2x4 minimum) Bearing wall, Versa -Lam LVL or Glulam Beam KNOCKOUTS) ALLOWED IN BEARING ZONES —� DO NOT cut, notch or drill flanges Boise Joist Blocking Use 3" (10d) nails at 6" o.c. Load bearing walls higher than 15001b. BLOCKING PANEL, INTERIOR Vertical load transfer =1900 plf max. along bearing wall Required on interior walls : - for vertical load transfer when load bearing - for lateral support when joists meet over wall, or wall stacks directly over wall or Plumbing beam below Load bearing wall must stack over blocking and wall or beam below.* Lt Joist AIL When joists meet over wall, provide �1 3/4" minimum bearing for each. I -Joist can be offset up to 3 to avoid vertical plumbing 3" max JOISTS OFFSET J N.T.S. Provide adequate bearing for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist blocking panel *Non -stacking walls 10dnails SECTION @ INT. BRIG. WALL require additional consideration. N.T.S. MINIMUM SPACING = 2x GREATEST D DIMENSION OF LARGEST HOLE (see table below) (KNOCKOUT EXEMPTS) D (see table below) Joist hanger tfl co 1Y" ROUND HOLE MAY 611 611 DO NOT CUT HOLES BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y2" THE WEB. PROVIDE AT ROUND IN LEAST 3" OF CLEARANCE CANTILEVERS, FROM OTHER HOLES MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1%" 1' Z' 1' 2" T-3" 1'-3" 1'-7" 1'-11 °` 2'4" 2'-J' 3'-2.. 3'-T. Any 1_0 jolt 12 T-0" T-1" 1' 2" 1'-2" T-3" T-9' 2'4" 2'-11" 3'-T' 4'-2" 4'-9" -i4" Sian fit} ___ 16 T-0" T-1" 1'-Z' 1' 2" T-T' 2'-5" 3'-2' 3'-10" 4'-9" 6-7 6'-L1" T-2" 20 T-O" 1'-1" T-2" 1'-2 " 2'-0" 3'-0" 4'-0" 4'-10" 5'-11" 6'-11" 7'-11 ' 8'-11" 24 V-0" T-1" 1' 2" T-3" 2'-5" 3'-T' 4'-9" 6-10" 7 2" 8'-4" 9'-6" 10'-9' NOTES: 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7. 1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1%" KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. HOLE CUTTING CHART N.T.S. USP MUC 5/8" o THRU BOLT us ML R TRUSS 'OP PLATE I.0 TYPICAL USP MUGT15 TO BUILT-UP COLUMN DETAIL LC SE TYPICAL HUS INSTALLATION TYPICAL HTA 20-18 / HTA 20 INSTALLATION A/C CHASE 4" PVC SLEEVE THRU STEM WALL � _ g Backer block (12" wide min.) = Nail with 10 10d nails.I—III=1 I I— —III — �nstall tight to top flange. d a . SLEEVE THRU STEM ° SEE PLAN FOR °. ° .. _; . . ° n. ° FOUNDATION INFO ° n STEM FOUNDATION r—GRADE _n�lklr or-r- MI AKI Filler block. Nail with 10-10d nails. Backer block required where top mount hanger load exceeds 250 lbs. Install tight to top flange. 1/4" 2" gap I I r Backer Block "Top Mount" "Face Mount" Backer block shall be tight Backer block shall be tight to bottom of top flange with to top of bottom flange with 1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top flange. flange. eb stiffner as Web stiffeners are not required when top required if hanger flange is laterally supported by joist hanger. doesn't meet height -� requirements -0.6 X Joist depth ` I I -JOISTS BUCKETS N.T.S. rvt, k nr•»c r+ rv%, SLEEVE THRU FOOTING MONO FOUNDATION AIN. EMBEDMENT SCHEDULE FOR AND QUANTITY )F FASTENERS HTA 20-18 / HTA 20 INSTALLATION @ MID SPAN NOTE: UPLIFT VALUE IS BASED ON S.P.F. USP RT16 USING 16-8d x1 1/2" NAILS UPLIFT = 1030# TYPICAL RT16 INSTALLATION TYPICAL MTW INSTALLATION TOP (2) #5's x 4'-0" v CENETERED @ PIPE PENETRATION d a..° °. ITI I ITI I—III—� a a FINISH GRADE TYP. FND. PENETRATIONS SCALE: N.T.S. PLUMBING LINE PVC OR SCH40 SLEEVE a 1= SEE FND. PLN. SIZE & REINF. 12" BELOW PIPE VERTICAL THRU FND. GRADE TOP (2) #5's x 4' 0" —\ CENETERED @ PIPE PENETRATION a a ° PVC OR SCH40 SLEEVE r—PLUMBING LINE d L a a in Z • ° • ' SEE FND. PLN. SIZE & REINF. PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE CENETERED @ PIPE PENETRATION PLUMBING LINE ° .4 4 1=1 I I —III: "' -III—III—I a ° ` 1=III-T— SEE FND. PLN. SIZE & REINF. O" co a co Ci t!9 (D Q) v) Lt.l c) 0 p V E o Cn M m w-- O o m r` i V � y `..J N Cl) L U V— E —o C� M M CD -d M O`o0 z wrw �U_00 o '0 k '.''�`%t Y (n O O M Q °on rn Q o A 0 B D. `I D` -. $ ` W ", CD T P . 0 ra O � O JIB t C Ib •� z���owr UL- Q W � �`Cqrr R,�J To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD CD Z N o 14O -;_J I4 M O rn Q fu Ln °-N0 Ln Q C" L QU0-o z E § ro Z WJ O d" mi H oZ o �o w Z as Z� ¢Q f� U Z, 0 U Z U Z Q p w Z U O cc o W mzo LLI Z o T—I 0 Q U 2:Z g F-I O Z 3 (a N Q F 8 o T� O > �< U o� boo t. 0 U wao8 CD V � m J o¢oa N '~^ F o w 2o Q Z N QQ� Wa o Z LU L 0 LLI Q o tJ.J ¢ z o w o O Y Q u,o cM �' W a,Z d- z a z J o O n � _ aZ r 1 *-I D_ M SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION NO. 200 SHEET NO. SN 1 FOR UNDERLAYMENT REQUIREMENTS SEE R905. 12 (TYP.) VARIES / INS (1) LAYER TYPE 11 (430) UNDERLAYMENT FOR ROOF PITCH >4:12 (2) LAYERS TYPE I OR TYPE II (#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. PRE ENGINEERED WOOD TRUSS @ 24" O.C. U.N.O. HURRICANE ANCHOR @ EACH TRUSS (SEE UPLIFT SCHED.) W/ METAL PL. UNDER EA. TRUSS MOISTURE BARRIER SHINGLE ROOF 7/16" O.S.B. MIN. SEE ROOF NAILING SCHEDULE ON SHT. e r'li I 5/8" OR 1/2" HIGH STRENGTH CEILING BOARD PER CODE (OR 5/8" GYP. TYPE "X" @ GARAGE ALUMINUM DRIP EDGE ALUMINUM FASCIA W/A HABITABLE ROOM 12" N.O. 2x SUB FASCIA ABOVE) W/DRYWALL SCREWS @ 7" O.C. CEILING & 8" O.C. WALLS EE SOFFIT SHEET 8"x8"X16" KNOCK -OUT INSULATION PER CHART ON FLOOR BLOCK W/ 1#5 CONT. FILLED SOLID W/GROUT PLAN 1x2 P.T. HORIZONTAL NAILER 8" C.M.U. TYPICAL STD. 90-HOOK (SEE DETAIL) TYPE "S" MORTAR ARCHITECTURAL FINISH 1x2 PT WD FURRING @ 24" O.C. 1/2" GYPSUM WALLBOARD---'(1) #5 VERT. IN FILL U.N.O. CELLS (SEE FOUNDATION PLAN FOR LOCATIONS) 1x4 P.T. BASE NAILER 4"x4" INSPECTION 3 1/4" BASEBOARD PORT AT EACH FILLED CELL TYPICAL MIN. 2500 PSI CONC. SLAB M AT GARAGE CONTRACTOR MIN PSI MAY VARY PER TO CUT BLOCK OR POUR MUNICIPALITY. CURB DUE TO SLOPE CONCRETE SLAB W/ 6X6 a NOTE:EXTEND W1.4XW1.4 WWF OR "FIBERMESH" DECO FINISH 4" to 6" BELOW GRADE CV i CIO D' 00 6 MIL VAPOR III D III=I I = = z I BARRIER I D I l i II I I g COMP. SOIL. (COMPACTED TO 95% MODIFIED PROCTOR III I I I I I=1 I I —I I ASTM D1557) 3" MIN. CLR. (2) #5 REBAR CONT. ON 3" CHAIRS TYP. 4" V-4" STD. 90 HOOK (SEE U.N.O. DETAIL) TYPICAL WALL SECTION rA SCALE: 3/4" = 1'-0" S3 OPT: DEPRESS SLAB 5 %" DEEP AND 6" BEYOND DOOR TO - RECEIVE PAVERS / DRIVEWAY CONCRETE SLAB PAVERS BLOCK WALL BEYOND 14 O.H.D. RECESS ..a�. III 111 f =III= SEE A/S3 OR J/S6 J -� I III —I 11 I I 1 11= — I 1 I I— a III—' " FOR REINF. INFO. 3" MIN. CLEARANCE 1 4 (1 STORY) / 1 -8 (1 STORY w/ DEPRESSED SLAB OPT.) 1' 8" (2 STORY) GARAGE DOOR SLAB RECESS J.1 SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. 2x #2 SPF STUDS - @16" O.C. W/ (2) 16d TOENAILS T & B 2x P.T. PLATE--\ (2) #5 CONT. ON 3" CHAIRS (TYP.) D -III-III-I m ° I Ii,llll�t—`I�IIIII�I� I l ° (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. <_ 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z APPLICABLE. 1/4" DIA. X 31/4" TAPCONS @ 24" O/C $ c @ 6" MAX FROM END OF 2 x PLATE 6x6W1.4xW1.4 N WWF OR FIBERMESH Cl) TYPICAL INTERIOR BEARING WALL W/OUT UPLIFT rG SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. LOAD BEARING OR EXTERIOR WALL SEE CC/S3 OR — G/S3 FOR ANCHOR BOLT INFO. (IF NO UP LIFT ON WALL SEE GG/S3) *USP SPT22 TYP. - MONO OR STEMWALL— FOOTING MONO SHOWN FOR CLARITY e NOTE: *FOR BEARING WALL W/ UPLIFT ONLY SCALE:3/4"=V-0" S3 8"x8"x16" NOMINAL BLOCK WITH 3/8" MORTAR BETWEEN COURSES GARAGE SLAB AT STEP SCALE: 3/4"=1'-0" 2x S.P.F. STUDS 2x STUD 8" C.M.U. 1"x P.T. STUD d #5 VERT. IN FILLED CELL N 5/8"x6" "J" BOLTS BOLT @ 24" O.C. VERT. OR 5/8" x 6" EPDXY BOLT OR (6) 1/4"x31/4" TAPCONS SPACED EVENLY 2x P.T. PLATE ASSUMED FINISHED — GRADE co p p ' D p'� —III—III—III — = 1=III—III=III—II � g III III III —III —III N —i i— --_ FRAME WALL TO C.M.U. WALL CONNECTION SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" S3 SLAB INFORMATION. 6x6W1.4xW1.4 3 1/2" WWF OR FIBERMESH min.) 4' �r GRADE 00 _ Ii1 ICI ICI—ICI—I� -(1) #5 REBAR w/ OPT. =1I I-1I I-1I1= I1= I I-1I I- I1=SCREEN ENCLOSURE MIN. TYPICAL THICKENED SLAB EDGE L SCALE:3/4"=V-0" S3 BLOCK WALL BEYOND EXPANSION JOINT 13" —I r-O.H.D. RECESS III ,ICI I I_I -1r 1 I —I I 1=1 I I 4„ ll SEE A/S3 OR J/S6 J -1 l �l l I l l7 i il" 1111 j111- FOR REINF. INFO. 3" MIN. CLEARANCE V-4" (1 STORY) V-8" (2 STORY) GARAGE DOOR SLAB RECESS SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING — NAILED W/ 8d COMMON NAILS @ 4" O/C BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. (2) ROWS OF 2x BLOCKING @ THIRD POINTS 5/8"OR 1/2" HIGH STRENGTH —� (U.N.O.) (OR 5/" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM ABOVE) S.P.F. DOUBLE TOP PLATE USP SPT24 CONNECTOR 1/2" CDX PLYWOOD OR 7/16" O.S.B. SHEATHING REQ'D. FOR ALL EXTERIOR OR SHEAR WALLS AS INDICATED ON THE PLAN. ATTACH SHEATHING W/ 8d COMMON NAILS @ 4" O.C. @ BOUNDARIES, 6" O.C. @ 3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD SLAB & BLOCK 5/8"° x 10" "J" BOLT @ 24" O.C. W/ 2"°x3/16" PLATE WASHER (TYP.) ELEV. U-0" (ALT: 1/2"x12" TITEN HD @ 24" O.C. OR 5/8"x10' WEDGE ANCHOR @ 24" O.C.) 2" A.F.F. 1/2" MIN. ELEV. -0'-3 1/2" 0 �3 b . D A.F.F. p LL 4-11-111 CD 04 00 -TRUSS BOTTOM CHORD OR 2x4 BLOCKING 5/8"OR 1/2" HIGH STRENGTH W/ 2-16d TOE NAILS @ EACH END (U.N.O.) (OR 5/" GYP. TYPE "X" @ -SEE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) TRUSS ALIGNED WITH STUD BELOW S.P.F. DOUBLE TOP PLATE -2"x S.P.F. (OR EQUAL) STUDS 1161, O.C. U.N.O. USP SPT24 CONNECTOR {1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. < 8'-1 (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". INSULATION PER CHART ON FLOOR PLAN USP SPT22 CONNECTOR 5/8"° x 10" "J" BOLT @ 24" O.C. W/- 2"°x3/16" PLATE WASHER (TYP.) •2x P.T. BOTTOM PLATE (ALT: 1/2"x12" TITEN HD @ 24" O.C. OR 5/8"x10' WEDGE ANCHOR l6x6W1.4xW1.4 @24"O.C.) WWF OR FIBERMESH 1/2" (min 4" 31/2"(min. -4"III—III- - • I I I —III II=I 11=1 I I=III I I I=1 I I I I' (2)#5CONT .1 -11, III fit 4" V-4" 8" U.N.O. MIN. TYPICAL BEARING WALL cni STEP as SHEARWALL "SHEAR WALL" SCALE: 3/4"=V-0" TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ 2-16d TOE NAILS @ EACH END SEE UPLIFT SCHEDULE FOR UPLIFT CONNECTIONS. PROVIDE (1) USP HTW20 WHEN TRUSS ALIGNED WITH STUD BELOW --2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. --(1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". --4NSULATION PER CHART ON FLOOR PLAN —USP SPT22 CONNECTOR /2x P.T. BOTTOM PLATE 6x6W1.4xW1.4 WWF OR FIBERMESH 31/2" MIN. I b ° . III=III=III—' 1/2"(min.)-4" 0— I —III —III 31/2"(min.) - 4" —III—I I-11 I=ll-1 I I (2) #5 CONT. 4„ I fit I �6i i i I I 8 U.N.O. MIN. TYPICAL BEARING WALL @ STEP rcc SCALE:3/4"=V-0" S3 -2x STUDS @ 16" 0/C (1) ROW 2x BLOCKING @ MID HGT. /.o' FOR WALL HGT. <_ 8'-6". (2) ISULATION PER CHART ON FLOOR PLAN NOTE: ROWS 2x BLOCKING @ 3rd PTS SEE SECTION C/S3 FOR FOR WALL HGT. > 8'-6". 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 ADDITIONAL INFORMATION LAYERS W/ TOTAL THICKNESS 7/8" OVER 1/2" GYP. WB (MIN.) @ GARAGE LATH FIRST 2 " HICK EA CONTINUOUS TO FOOTER BELOW 90 FIOOK DETAIL SIDE IF APPLICABLE. PAS c 5/8"° x 10" "J" BOLT @ 24" 1 W/ 2"°X 3/16" METAL LAYERS 3/8 T CH. USP SPT22 CONNECTOR PLATE WASHER TYPICAL 3RD LAYER 1/8" THICK. K.O. BLOCK 5/8 EXPANSION BOLT @24 " O.C. 2x P.T. PLATE W/ 7" EMBEDMENT MIN. SHEAR_ SP SPT22 @ EA. STUD ( MIN. 2500 PSI CONCRETE SLAB W/ 3500#, MIN. TENSION 2600#) 6 x 6 W1.4 x W1.4 WWF OR 2X P.T. PLATE 20"MIN. LAP [24"MIN. LAP] SPACE ANCHOR FIBERMESH #5 REINFORCING BOLTS 6" MAX FROM 6 x 6 W1.4 x W1.4 WEEP SCREED INSTALLED BAR END OF 2" x PLATE WWF OR FIBERMESH T c PER MANUF. w D #3 OR #4 REINFORCING BAR W D GRADE 40 MIN. Fy= 40ksi -j N z #3 & #4 LAP SPLICE a ° D [GRADE 60 MIN. Fy= 60ksi] —I ((—III—III p . • =1 III —III Cl) -0 D FINISH GRADE 25" MIN. LAP [30" MIN. LAP] a I —III —III —III 1 I I l III —III —III= —i I I=i 11= III D ° ° — — — W III I II 1 III I III III ° —�` —III I _I 11 I111; 6 MIL VAPOR BARRIER L III ° I I—1 I I—dL-11 R 1 7/8" I I— I —III —III —III I —Ill I I —III= -1 I' ll=III=1 #5 REINFORCING BAR —' I I III—III—III-1 I I III=1 I I I 11- III I I —I 11=I 11=1 11=1J N Z 2 #5 CONT. —III-I I I=I I,,, III=1JI I=11 I I=11 #5 LAP SPLICE () „ III D I=III=L=III=� I' 36" MIN. LAP [36" MIN. LAP] ON 3 CHAIRS 8„ V-4„ 8„ COMP. SOIL. (COMPACTED TO =� _ _ (TYP.) 95% MODIFIED PROCTOR ASTM �= 1=III=1 I I=III=1I I=1I I=�=11'- 10" D1557) I�' 4" 1'-4° #6 LAP SPLICE #6 REINFORCING BAR #5 STD. 90 HOOK TYPICAL INTERIOR BEARING TYPICAL EXTERIOR FRAME WALL FOOTING rE REBAR DETAILS rF'�'� WALL W/ UPLIFT rG SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" S3 SCALE: N.T.S. S3 SCALE: 3/4"=V-0" S3 SLAB INFORMATION. VARIES = SEE PLAN 1 1/2" RECESS FOR 6 x 6 W1.4 x W1.4 FRAME -DOWN FALSE BEAM w/ (3) WWF OR FIBERMESH ;' 10d NAILS TO TRUSS TOP CHORD SEE ROOF PLAN S.G.D. (U.N.O.) M . AT 24" O.C. MAX. FOR TRUSS SEE PLAN FOR CONNECTION INFO TOP OF BEAM &LAYOUT DESIGN- 71 SEE ROOF PLAN c_ _ _ _ _ _° ° ° FOR STRUCTURAL E - I I —III= III 1 BEAM SIZE & CONNECTION INFO r� 2x4 #2 SYP P.T. FRAMING w/ SEE A/S3/J/S6 -III 'III=11 I, 111-1 I I "� I' MIN 7/16 O.S.B. SHEATHING FOR REINF. INFO. 1 8 o ATTACHED PER NAILING OPTION #1 w SCHEDULE 1/2" GYP. BD. ¢ > SEE TYP. WALL SECTION FOR ADDITIONAL P.T. 2x > SLAB INFORMATION. HOLD GYP. BD. w 2' 1/2" FROM SLAB N SLAB STEP & RECESS S.G.D. rM Ol J CONT. BEAD SEALANT SEE FLOOR PLAN FOR SCALE: 3/4"=1'-0" S3 -- INTERIOR -3 1/2" a ° CONCRETE NAILS W 1 1/2' EMBEDMENT @ 12" O.C. STAGGERED, FROM BOTTOM PLATE TO CONCRETE (MIN. SHEAR 180# MIN. TENSION 121 CONCRETE SLAB a° 00 N "T M 6 MIL VAPOR = — = (- BARRIER =III=1 1 1 1 4" 4" INTERIOR WALL SLAB STEP NON-BRG. SCALE: 3/4"=V-0" —2X STUDS @ 24" O.C. U.N.O. GARAGE �1/2" GYPSUM WALLBOARD U.N.O. W/ DRYWALL SCREWS @ 8"O.C. —INSULATION PER CHART ON FLOOR PLAN CONT. BEAD SEALANT E 6x6W1.4xW1.4 N WWF OR FIBERMESH c,•, ° 4 a iO —III—III—III=i I I=III=1 I I K S3 U-0" FIN.-0" FIN. FLR.� — STRUCTURAL COLUMN SIZE & BASE CONNECTION INFO. SECURE 2x4 P.T. BTM. PLATE w/ 1/4"x3" TAPCONS AT 8" O.C. `—TRIM PER PLAN SQUARE CMU BLOCK BASE, SIZE VARIES PER PLAN w/ MIN. (2) #5 VERTICALS 1 FILLED SOLID J BRICK PAVERS or SLAB PER COMMUNITY SPECS 00000 �-•000000%%o MASONRY WALL AND PAD FOOTING 8" MASONRY WALL EXTEND FILL CELLS c TO FOUNDATION PAD CONT. FOOTING STEEL MAT REINFORCING. r ' Cl) 00 GRADE_ a C� ;III III ° ° ° • — —III— Z w o =1 —III—III—III=11 LU O o (' = 1111111111 G� I —III —III z Q LL U 1= a a = — _ - m — W N =III=III—III—III ==III —I FOOTING J l l l —III—III—III=1—I—I I- - i1T�iii� BEYOND PAD REINFORCEMENT - 3" MIN. CLEARANCE (SEE SCHEDULE) FOOTING WIDTH SEE SCHEDULE PATIO COLUMN FTG. DETAIL(N"� SCALE: N.T.S. �3_ C� o --- �I J z 0 u� M �U — OLU Of E 0 Mo C%i r o CO L.0 �,�.. E t0 '0 co - ° O `O o M ) �LLco on W Y � ao Lr) O �T m rn Q o A U 'cBo to e'' t 9 'a S'.Y Cq a nto� .. W> c c�Q,a aE m� LL #j v Z' n� us", - te i oy-15 rid°"�O,,j�`i/�t Y`'f .LJ ❑ qi li�fl To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z (V 0 (3) O M O QM_L0 a- U i Q L o_ U 00, z E Z J S W oZ o a p z < Z < V J J Z a a w < Ce a: oa�0 Z wj z �— < �owZ w W 0 J M O��N J w mzo H w oN Z Z Q 0 r-I g Z Z6 Ln3 z S o ,-� 0 U (n Q 0 d' 0 `"{ z <R0 J O` w x0 O O U Q_ oQouj Q N �*< aow3 $off° Z � � O Z W N U-)=aLL� w Sao~ J rl W Q Q Z o Cwu EQ` ~ QZ M M Z t7uJ a(n o � g = 0 ¢z r, *-+ a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION NO' 10 SHEET NO. S3 (MONO) i i i 12 (TYP) SEE ELEV. USP SPT24 @ EA. STUD CRICKET AS REQUIRED SINGLE 2x CONT. BASE (2) 2x6 OR (2) 2x8 TOP PLATE SEE PLAN (2) 2x HEADER TO SIT 2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE SEE PLAN FOR HEADER SEE PLAN FOR SIZE CONNECTION 2x DEAD WOOD @ MID POINT w/ (3)12d TOEEAILS SPACED DOUBLE 2x TOP EVENLY PLATE HEADER FLUSH TO OUTSIDE OPTION 2x BLOCKING @ EACH END W/ 10d @ 4" O.C. FROM EACH HEADER FACE TO BLOCKING (2) 2x HEADER PER PLAN VARIES 2x BOTTOM PLATE W/ (1) 10d @ 8" O.C. TO EACH HEADER FACE 2 x 6 (MIN.) FRAME WALL HEADER DETAIL 1 SCALE: N.T.S. S4 SEE TYPICAL WALL SECTION PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2x4 SPF. #2 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT. TOP PLATE W/ (2) 12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ (3) 10d TOENAILS T&B AS REQ'D 2x BLOCKING @ MID POINT EVERY OTHER .' STUD W/ (3) 10d NAILS PLATE W/ (2) 16d TO TRUSS BELOW Ix 112" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" O/C FIELD USP SPT22 @ EA. STUD 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W/ 8" EMBEDMENT 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 90^ HOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL K/S4 SEAT FOR BLOCK IS POURED IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERALNOTES SLOPE FORWARD FOR DRAINAGE BLOCKING (TYP.) \--200F TRUSS IFT CONNECTOR (SEE SCHEDULE) ISTURE BARRIER SCALE: N.T.S. SEE PLAN FOR FOOTING DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T.S. VENT OR 2ND FLOOR 1/2" MINIMUM CEMENT FINISH TYPICAL C.M.U. WALL STANDARD 3" DIA. TEE 3/4" FURRING STRIPS THREADED 3" DIA. EXTENSION 1/2" GYPSUM BOARD SCREW OFF CAP (3" DIA.) W/ DRYWALL SCREWS FOR CLEAN -OUT @ 8" O.C. OR 4d MIN. EXTENSION FROM DRYWALL NAILS EXTERIOR FACE OF BLOCK WALL IS 1 1/2" MAXIMUM EXTENSION FROM EXTERIOR FACE OF BLOCK WALL IS 2 1/4" DRAIN WALL CLEAN -OUT A SCALE: N.T.S. S4 REFER TO WINDOW PRODUCT APPROVAL SHEETS FOR INSTALLATION INFORMATION BY MANUFACTURER. TYPICAL SECTION THRU WINDOW KNOCK -OUT NOTCH LINTEL WHERE REQUIRED BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT d 4 aQ 8" STD. 90 HOOK 8" LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS GREATER THAN 6-0" WIDE (U.N.O. ON PLAN) OPENING FILLED CELL W/ (1) #5 VERTICAL SEE FDN. PLAN FOR LOCATION --- NOTES:- FILL LINTEL AND ALL CELLS ABOVE LINTEL. NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. O VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY. O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. ® OPENINGS LESS THAN OR EQUAL TO 6-0" IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN. TYPICAL FILLED LINTEL ASSEMBLY SCALE: N.T.S. WIDTH OF OPENING VARIES 4"FORM CONCRETE INSET TO 1/2"X9 1/2" PLYWOOD CREATE A SOLID BASE FOR SCRAP MATERIAL BLOCK WALL ABOVE. J w T O FORM CREATES CONCRETE RECESS TO 2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. KEEP STIFFENER BACK FROM SIDES ENOUGH TO ALLOW SPACE FOR FLAT MASONS TOOLS (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) MOUNTING BASE SHOWN IN POSITION GARAGE ENTRY FORM DETAIL 2x6 MOUNTING BASE SCALE: N.T.S. /--8x8xl6 C.M.U. GARAGE DOOR TRACK MOUNTING BRACKET WS GARAGE DOOR ROLLER GARAGE DOOR TRACK VIS CONNECTION ASSEMBLY .,, GARAGE FLOOR TRAVEL DIRECTION OF GARAGE DOOR MOUNTING BASE DETAIL SCALE: N.T.S. a a a POURED CONCRETE BASE FOR BOTTOM OFMOUNTING B BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED FOR GARAGE DOOR AND WATER GARAGE FLOOR. SHED FORWARD THIS DRAWING. PARTIAL INTERIOR ELEVATION SCALE: N.T.S. 7 5/8" 8" 7 5/81, 8" 7 5/81, 8" INTERIOR WALL Gt EXTERIOR WALL SOLID AREAS ARE STEEL AND GROUT FULL 8x8x16 BLOCK DOOR OPENING 1ST COARSE 2ND COARSE 3RD COARSE MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOOR JAMB WALL IS TO BE WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. MASONRY LAYOUT rD SCALE: N.T.S. SL� VERTICAL JAM 5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71 ", AND 96-3/8" ABOVE GARAGE FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) [TRUSS BOTTOM CHORD OR 2x4 TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO BLOCKING W/ 2-16d TOE NAILS NOT TRANSFER LOAD. @ EACH END WALL DOOR STOP w c� MOLDING vZCn a 2x TOP PLATE GARAGE V2-16 NAILS @ 24" O.C. OR DOOR EQUAL TO TRUSS BOTTOM CHORD OR BLOCKING 2 x 6 P.T. 2x STUD @ 24" O.C. MAX. PROVIDE P.A.F. NAILS OR 2x P.T. PLATE EQUAL @ 12" EO.C.. SEE A/S3 FOR STAGGERED FROM BOT. REINF. INFO. PLATE TO CONCRETE W/MOUNTING ANGLE NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. TYPICAL INTERIOR NON - BEARING WOOD FRAME WALL TYPICAL GARAGE DOOR BUCK K SCALE: N.T.S. S4 SCALE: N.T.S. S4 SOFA �0�2 �N 2x CRIPPLES @ --� 16" O.C. W/ (2) 12d TOENAILS T/B USP SPT4 w/ (6) 10dx1%"@24" O.C. 10d NAILS @ 8"-- O/C TYP. DOUBLE 2x CRIPPLE STUD TYPICAL (U.N.O.) HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS SIZE JACKS STUDS JACKS STUDS EA END EA END EA END EA END 1'-4' (1) (2) (1) (2) (1) USP LSTA30 4'- 9' (2) (3)+(2) (2) (2) (1) USP LSTA30 (4) (2) USP LSTA30 FLAT STRAPS PER CHART ABOVE TO BE BENT OVER TOP PLATE ** HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"xl0" OR GREATER HEADER 1 (2) 2x HEADER SEE PLAN S4 INTERIOR HEADER BOX HEADER (1) 2x SILL PLATE W/ (2) ONLY 12d TOENAILS. EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE '-2x STUDS TYP. USP HTT16 TYP. U.N.O. SEE N/S4 ** HOLD DOWN CONNECTIONS Op�00,Q NOT REQUIRED @ BEARING F4'/4,G WALLS NOTED WITHOUT UPLIFT P.T. BOT. PLATE WALL HEADER DETAIL rQ SCALE: N.T.S. S4 SPT4 •r• 2X STUDS @ 24" O.C. L P.T. ATE SEE TYPICAL WALL SECTION 12 PRE-ENGINEERED WOOD TRUSSES @ 24" O/C (TYP.) SEE ELEV. UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2"x4" S.P.F. TOP PLATE 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. ,-CRICKET AS REQUIRED USP SPT24 @ EA. STUD 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" BLOCKING (' O/C FIELD 2X4 PT STUDS @ 16" O.C. (2) 2X4 PT STUDS UNDER HIP CARRIER/GIRDER TRUSS = _ _ USP HTA20 @ EA. STUD MAIN SPAN MOISTURE BARRIER ROOF TRUSS UPLIFT CONNECTOR 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. (SEE SCHEDULE) AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 900 HOOK IN K.O. BLOCK ALT. KNEEWALL ABOVE MASONRY WALL DETAIL - PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON PSPN516Z wl (12) 16d NAILS TOP SPLICE 2 ROWS 10d @ 3" O.C. (14 > NAILS TOTAL) EA. SIDE OF AB, SPLICE STAGGERED • 4! 10d @ 8" 0/C ATTACH ALL EXTERIOR STUDS W/ 4 16d TOENAILS TO P PLATE NOTE: PLATE LENGTHS MUST BE BOTTOM SPLIC AT LEAST 4'-0" LONG. TYPICAL OVER STUD TOP PLATE SPLICE DETAIL M SCALE: N.T.S. S4 F= 2240 LBS •7 USP C uor or 1,+ SPT24 or or 14 1 SP SPT22 USP SPT4 TRANSOM FRAMING SEE SECTION AA/S1 AND BB/S1 FOR ADDITIONAL DETAILS RECESS LINTEL NAILED INTO TRANSOM FRAMING /ASP SPT4 / 2X8 P.T. BOTTOM P ATE USP SCALE: N.T.S. -2X TOP PLATE OVERLAPPING Od NAILS @ 6" TAGGERED I -BOLTS @ 24" O.C. NAX -2X P.T. PLATE 5/8"xl0" "J" BOLT @ 24" O.C. MAX. B C (MIN. (2) PER BOTTOM PLATE) uor or 1 If SPT24 SP S U S .1 TRANSOM FRAMING SEE SECTION AA/S1 AND BB/S1 FOR ADDITIONAL DETAILS RECESS LINTEL NAILED INTO TRANSOM FRAMING USP SPT22 /�SP / SPT4 / 011 d 2X8 P.T. BOTTOM PLATE 5/8"x10" "J" BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) ROOF TRUSS ABOVE 2X BLOCKING �-(2) 16d TOE NAILS EA. BLOCKING 2X8 WALL ABOVE ENTRY K.O. BLOCK W/(1) #5 CONT. & FILLED 5/8"X10" J-BOLTS @ 2'-0" O.C. C MASONRY WALL C 10d NAILS @ 4" A 10d NAILS @ 6" O.C. STAGGERED STAGGERED FB NSOM FRAMING 0 o YOND. PLYWOOD PLYWOOD FASTENED TO TRUSSES o E SHEATHING WITH 8d COMMON WIRE NAILS @ 4" S4 O/C BOUNDARIES 6" O/C EDGES B & 8" O/C FIELD PLYWOOD SHEATHING MASONRY SP WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) ALTERNATE: 5/8" DIA. ATR EPDXIED MIN. 6" INTO BOND BEAM @ 24" O.C. FRAMING DETAILS ABOVE ENTRY rR SCALE: N.T.S. S4 (0 N CL co C C Q) ,n 4--J Uj M 0 •U — 0 0 , ^) �v' OM CO N M C) N co '0 O00 N co co m rn C, C,Y v) o v rn Q o BD®Ln If qa ,N �� ,t d 9 _' v c0%a •,sf co _ %.' Z_W,- —�sgv LLf-, U4 ., W♦ � > .G W O 0cnv¢, C UvEt&oZ y .++ 1,ca a�>_m,, LU NQN = o ❑❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD O Z N O N r�, P1 +_' O > J) M O j f0 L^n a � n Ln Q LL i— CL CY U Q CO z < Z § E `. w C:)F' W �� 01 �0 3> wE z a WQ�� o00 ?UI z�w� 0owZ 0 J IL 0 w ono Z Z >o z ¢z 2: 5� Z Z) cp r-� O > z U � Q *x 0. QoP 0 CD F-- Ljj U2m2 a a N C)wow Zaoa uj on Q `I- Z Z N Waa J rl zo pzo LL 2:Q Paa M M Q Z u, au,Z o'tu er z OLU Q J = a z r, ?-I a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION NO. 10 SHEET NO. S4 SEE STRUCTURAL SEE STRUCTURAL NOTES AND TOENAIL W/ (2) 16d NAILS NOTES AND NAILING BACKNAIL W/ (2)16d NAILS NAILING SCHEDULE FOR SEE STRUCTURAL NOTES AND BACKNAIL W/ (2) 16d NAILS SCHEDULE FOR SHEATHING DETAIL @ 24 OUTLOOKER @ 24" O.C.7 NAILING SCHEDULE FOR USP RT16 OR EQUAL @ SHEATHING DETAIL 2x4 OUTLOOKER @ 24" TOP CHORD SHEATHING DETAIL EA. OUTLOOKER -SEE BLOCKING FOR OUTLOOKER ELEVATIONS)AL FIRST OUR 24" O.C. SEE STRUCTURAL — ROWS 45• t 24" MAX. TOP CORD BLOCKING 45°t 2X4 CONT"L" BRACE TOP CORD BLOCKING USP OR EQUAL @ NOTES AND NAILING TRUSSES USP RT16 OR FOR FIRST FOUR FASTENED W/ (2) 10d FOR FIRST FOUR ROWS 4 MAX. EA. OUTLOOKER UTL SCHEDULE FOR EDGES OF 2x4 CROSSBRACE EQUAL @ EA. ROWS OF TRUSSES @ 3"@ 24" O/C. CMID OF TRUSSES @ EDGES SHEATHING DETAIL SHEATHING APPROX. 8" FROM OUTLOOKER EDGES OF HEIGHT OF SHEATHING TYPICAL DOUBLE TOP PLATE 2"x4" CROSS BRACE TYPICAL @ RIDGE FASTENED AT "L" BRACE TO EXTEND SHEATHING TYP. 2X4 KICKER 2x8 SYP#2 "L" BRACE TO 2x4 CROSS BRACE APPROX. APPROX. 8' FROM 48" O.C. EACH JOINT W/ (3) 10d AT LEAST 90% OF WEB @ 8'4' 0/C. EXTEND @ LEAST 90% OF USP 8" FROM RIDGE FASTENED AT RIDGE FASTENED AT MAX. & (2)10d TOE NAILS @ LENGTH (SEE TABLE) 2x4 CROSS BRACE WEB LENGTH & NOTCH @ SPT4 @ EA. EACH JOINT W/ (2) 10d & (2) EACH JOINT W/ (2) EA. END @ 48" O.C. APPROX. 8" FROM BOTTOM CHORD (SEE STUD 10d TOE NAILS @ EA. END 10d & (2) 10d TOE 2x6 P.T. GABLE TRUSS RIDGE FASTENED AT TABLE) 2X6 FRAMED WALL - SEE NAILS @ EA. END • SILL 1/2" CDX PLYWOOD OR EACH JOINT W/ (2) 10d USP RT3A WITH 8-8d WALL SECTION FOR SPACING 7/16" OSB SHEATHING & (2)10d TOE NAILS @ FROM LEDGER TP 2x4 PANEL BLOCKING — J ATTACHED W/ 10d EA. END BLOCKING 1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE NAILS @ 6" O.C. EDGES GYPSUM WALL BOARD GABLE TRUSS OSB SHEATHING ATTACHED FIRST (4) ROWS OF AND 12" O.C. FIELD 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 1/2" CDX PLYWOOD OR W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. 10dX3" @ 3" O/C (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM 7 7/16" OSB SHEATHING AND 12" O.C. FIELD END TYP. TOP & THROUGH CHORD CORD ATTACHED W/ 2 16-d TOENAILS () ATTACHED W/ 10d NAILS 2 16d NAILS () BOTTOM ATTACHED IL INTO 2"x6" P.T. PLATE 2"x4" LEDGER (MATCH BOTTOM CHORD @ 6" O.C. EDGES AND 12" 2x4 PANEL BLOCKING @ 48" 2x4 BLOCKING W/ (2) 16 d TOENAILS 2x4 "T" ON TOP OF PANEL BLOCKING, WEEP SCREED SLOPE OF ADJACENT SCISSOR TRUSS) O.C. FIELD O.C. FOR THE FIRST (4) ROWS FASTEN WITH 10dx3" @ 4" O/C SPACED INSTALLED PER MANUF. 2"x6" P.T. SILL NOTCH "L" BRACE HERE OF TRUSSES FROM EA. END 2x4 "T" ON TOP OF PANEL @ 48" O.C. 5/8" x 10" "J" BOLT @ 48" O.C. TYP. TOP & BOTTOM ATTACHED BLOCKING, FASTEN WITH 4USP MOISTURE BARRIER WEEP SCREED W/ (2) 16-d TOENAILS 10dx3" @ 4" O/C 5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM USP EQ. 618 O.C. TYPICAL. INSTALLED PER MANUF. PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER HTA20 @ EA. TRUSS @ . T ALTERNATE U T ALTERNATE USP LSTA18 STRAIGHT STRAP @ 4'-0" O/C ALIGNED WITH GABLE WEB. ATTACH TO TRUSS MOISTURE BARRIER 2x4 LEDGER (MATCH BOTTOM CHORD SLOPE OF ADJACENT VERT. WEB MAX.) W/7-10dx1 1/2" AND TO MASONRY W/ (3) 3/16"x 2 1/4" TRUSS) NOTE: IF EMBEDDED SECTION TAPCONS. SECTION ::� STRAP MISSED VERTICAL 1 2 SECTION WEB; USE MSTAM36 ON OUTSIDE SCALE: N.T.S. SS SCALE: N.T.S. �,S5 SCALE: N.T.S. S5 SP HGAM10 W/ (4) 4"x1-3/4" WEDGE OLTS & (4) SDS 114 1 1/2" SCREWS REFER TO DETAIL J ON SHEET S5 FOR N N SEE STRUCTURAL— X-BRACING, AND TOP NOTES AND NAILING CHORD BLOCKING N SCHEDULE FOR INFORMATION `O 00 co SHEATHING DETAIL 1 1 1/ 2"x4" CROSS BRACE - WOOD TRUSSES 60 00 APPROX. 8" FROM RIDGE FASTENED AT 2x4 RAT RUN BRACING EACH JOINT W/ (2) AT 24" O.C. ON TOP OF 1 1 2^ 1 1 2 10d & (2) 10d TOE BOTT. CHORD FOR 4 ^ NAILS @ EA. END TRUSS SPANS �JLRII' ATTACHED W/ 2 - 16d 2x4 PANEL BLOCKING AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW @ 48" O/C FOR THE (3) 2 x 6' LAMINATIONS W/ (2) ROWS OF 2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS TRUSSES FROM EA. FIRST (4) ROWS OF 2x4O/C L 2 - IN (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 4 1/2") OR EQUAL (D = 0.207", L = 4 1/2") OR EQUAL END TYP. TOP & TOENAILS @ EA. END NOTES: BOTTOM ATTACHED 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL W/ (2) 16-d TOENAILS MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) EXT. WALL CONN. @ 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION NON -LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SEE TYP. WALL SECTION FOR SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS r8 ADDITIONAL INFORMATION. 2"x4" OUTLOOKER @ 24" - O.C. W/ (2) 10d PER JOINT IINIMUM 2x :ROSS BRACING 3EE PLAN FOR OCATIONS) j 10dx3" O/C @ TOENAIL 6" O/C RUNN W/ (2) 16d TYPICAL (2) 16d PER NAILS JOINT +— CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 CROSS BRACING DETAIL K,_�j ALTERNATE NON -DROP GABLE END DETAIL SCALE: N.T.S. S5 1 GABLE TRUSS 55 "L" BRACE W/ 10d @ 4" O.C. 12 (SEE SCHEDULE FOR SIZE AND LOCATION) 6.9 MAX. S5 S5 SCALE: N.T.S. ' 11 4 1 N d, J- \ I Adl L I �Il "IE II �- CONT. BEARING GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. SCALE: N.T.S. PRE-ENGINEERED WOOD TRUSSES BACKNAIL W/ (2) 2x4 OUTLOOKER 8d @ 6"O/C 16d NAILS F@ 24 O/C TOP CORD WOOD TRUSSES BLOCKING FOR USP RT16 OR FIRST FOUR ROWS 7M..EDGES EQUAL @ EA. OF TRUSSES @ OUTLOOKER7Z OF SHEATHING TYP. "L" BRACE TO EXTEND AT LEAST 90% OF WEB LENGTH (SEE TABLE) GABLE TRUSS 112" CDX PLYWOOD OR 7/16" (2) 16d NAILS OSB SHEATHING ATTACHED W/ 10d NAILS @ 6" O.C. E ES AND 12" O.C. FIELD USP HGAM10 W/(4)-3/16"x1-3/4" ' - JACK TRUSS WEDGE BOLTS & (4) SDS 1/4" x 1 SEE PLAN FOR 1/2" SCREWS CONNECTION 2x4 "T" ON TOP OF PANEL) BLOCKING, FASTEN WITH L 2x4 BLOCKING W/ 10dx3" @ 4" O/C (2) 12d TOENAILS El, SECTION g SCALE: N.T.S. S5 OVERLAP TRUSS BRACING AT LEAST TWO TRUSS SPACES -MINIMUM (2) 16d PER JOINT \-MINIMUM 2x4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL SCALE: N.T.S. 6" OVERLAP M S5 "L" BRACE W/ 10d @ 4" O/C (SEE SCHEDULE FOR SIZE AND LOCATION) GABLE END BRACING DETAIL SCALE:3/4"=1'-0" MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION BACKNAIL W/ (2) 2x4 OUTLOOKER 16d NAILS F@ 24 O/C TOP CORD BLOCKING FOR USP RT16 OR FIRST FOUR ROWS EQUAL @ EA. OF TRUSSES @ OUTLOOKER 24" MAX. EDGES OF SHEATHING TYP. "L" BRACE TO EXTEND AT LEAST 90% OF WEB LENGTH (SEE TABLE) GABLE TRUSS 1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING ATTACHED W/ 10d NAILS @ 6" O.C. EDGES AND 12" O.C. FIELD (2) 16d NAILS 2x4 "T" ON TOP OF PANEL BLOCKING, FASTEN WITH 1063" @ 4" O/C USP HGA10 @ 36" O.C. DBL. TOP STUD WALL PLATE (SEE TYP SEC) 2x4 BLOCKING 2x4 "T" BLOCKING @ 48" O.C. 16d NAIL "L" BRACE ATTACHED W/ 10d NAILS @ 4" O.C. TYPICAL GABLE TRUSS WEB DOUBLE "L" BRACING DETAIL 5 SCALE: N.T.S. S5 2x4 "T" BLOCKING 2x4 BLOCKING @ 48" O.C. "L" BRACE ATTACHED 16d NAIL W/ 10d NAILS @ 4" O.0 N TYPICAL 4n GABLE TRUSS WEB SINGLE "L" BRACING DETAIL 6 SCALE: N.T.S. S5 DIAPHRAGM BLOCKING @ 48" O/C GABLE TRUSS TRUSS VERTICAL USP SPT24 @ EACH STUD (2) 2"x8" "L" BRACE FASTENED WITH (3) SECTION 4 16d PER SIDE SCALE: N.T.S. S5 SCISSOR GABLE "T" BRACE AS PER HIB 91 SCALE: N.T.S. (S5 2 x 4 BLOCKING W/(2) 10d TOE NAILS @ EACH END @ 24" O/C (TYP) \-BRACING W/(3) 10d x 3" @ • EACH CONN. @ 24" O/C MOISTURE BARRIER BOND BEAM MASONRY WALL ARCHITECTURAL FINISH EXT. WALL CONN. NON -LOAD BEARING LOCATIO (UNEVEN CLG.) SEE TYP. WALL SECTION FOR ADDITIONAL INFORMATION. SCALE: N.T.S. "L" BRACING REQUIREMENTS STUD SPACING NO "L" BRACE (1) 2"x4" (U.N.O.) "L" BRACE 2"4" (U.N.O.) "L" BRACE 24" 0'0" - T-0" T-0" - 6-0" 6-0" & GREATER SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND (2) 2'W" FULL HEIGHT @ DIAPHRAGM BLOCKING NOTE: 1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C. 3) SEE 6/S5 FOR MORE INFO. @ EACH STUD HIP FRAMING REFERENCE PLAN 0 z w x 20'-0" MAX 20'-0" MAX "X" BRACE SEE DET. J/S5 -, t- CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. o --- -- LU 0 o ' 9 O , z o w v w M o cal ;r o � d o o X Q Q r o o � W NOTE: 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACING THAT MY BE REQUIRED 2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN AS PER BCSI 1-03 SCISSOR TRUSS SCISSOR TRUSS W/ DROP CEILING BRACING DETAIL /TOP & BOTTOM CHORD GABLE END BRACING @ 4'-0" O.C. MAX. FOR FIRST (4) ROWS OF TRUSSES SCALE: N.T.S. 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ 2-10d @ EA. TRUSS (NOTE: BRACING MAY BE PLACED ON EITHER TOP OR BOTTOM OF THE BOTTOM CORD) COSMETIC DROP CEILING FRAMING MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION Cr) M t� Q co z O W cn -I--J w •U — O w �I F- 0 U) Mo V) m� C) W Ct M Cl) E U co O O _cD t LL. M Y MOM CL L0 O V < 0 'r CL A 0 N ao o �5°° Z i M'� , o a c" c Z. Z t W" Z O Z to LL�N W aN¢M� n To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z NO � Lj O > jr) M O M Q V) (0 Lr) z a L 0 Q U_ U-) oC U Q 00 z�E JC) W wow oz 0 Ln �o w Z n Z� aQ I; < of Z 0 U 0 U Z w = p w Z LH J W Iwo o� Zz >0 } F (� ¢ Z f �� O ¢ ru w S O ; 0 U C'3 z o� 0 a4 -' (V 0 Q x U0 U2 n� N LL 0d0a zQO_ z Z I� W�Q Q Z W N Lr) xa�0 awOZ �� J t-I Q W Q z Q 0Z0 P¢` 0 Q�z M M �¢ aM m ° Z g LL I = Q o Ln Z a SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION N0. L^ . O SHEET NO. S5 I 1 11 -1- 11 1 1X4 1/2" DRYWALL DOOR JAMB (REFER 1 X 4 1/2" DRYWALL DOOR JAMB (REFER 1 X 4 1/2" DRYWALL � UNACCEPTABLE INSTALLTION , DOOR JAMB REFER ( TO SHT. SDW2-K1 P.T. TO SHT. SDW2-K1 TO SHT. SDW2-K1 FOR CONN. DETAILS PROPER INSTALLATION MAX. 8 DO NOT DO THIS 40 2"x BOT. PLATE W/ (2)10d @ 6" O.C.. FOR CONK. DETAILS FOR CONN. DETAILS 1 X 4 1 X 4 e #5 REBAR (TYP,) ' 3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO PLATE W/ 8d 4" 1 X 4 3-1/4" LONG X 3/16"0 FURRING 3/16"0 X 3" LONG FURRING �� TAPCONS 3/16 0 X 3-1/2 LONG FURRING #5 REBAR AND NAILED W/ 8d COMMON @ 6" O.C. EDGES AND 12" O.C. FIELD 2X BOTTOM @ O.C., 2 ROWS STAGGERED TAPCON. INTO STAGGERED @ 16 TAPCONS STAGGERED 2X8 (TYP) BLOCK@ SPACING 1" DETAIL 1X8 P.T. STAGGERED @ 16" O.C. O.C. 2-ROWS INTO 2-ROWS INTO 1X8 W/ FACE PER MANUFACTURE MASONRY THROUGH 1-1 /2" DETAIL MASONRY THROUGH 3" DETAIL STD. 90^ ` D. 90° HOOK (TYP.) 2x BAND JOIST NAIL 10d @ TOP & BTTM CHORD, AND (8) 1x4 P.T. & 1x8 P.T. 1x8 P.T. & 2x8 P.T. FILL SOLID BOTH CELLS HOOK (TYP.) 4461 FACE NAILS 10d @ TRUSS VERT. WEB 3/16" x 3 -1/2" METAL SEAT PLATE TAPCON @ 16" O.C. & 4 FROM 1X4 P.T. 3/16 x 3 -1/2 DOOR JAMB (REFER 1 X 4 1/2 DRYWALL //4% NOTE: DOOR JAMB (REFER EACH END W/ MIN. 2" EDGE DIST. DOOR JAMB REFER TAPCON TO SHT. SDW2-K1 FOR TO SHT. SDW2-K1 CONN. DETAIL ® LAP SHEATHING TO BOTTOM TO SHT. SDW2-K1 JOIST TYPICAL FOR CONN. DETAILS FOR CONN. DETAILS 10d @ 12" O.C. 1 X 4 _ � FURRING 2X8 P.T. WITH 3/16"f?1 X 3" ' +2„ NOTC F@ @FIRST COURSE USP HGAM10 @ 12" O.C. w/4-SDS 1/4xl 1/2" SCREWS INTO BAND 2x P.T. AS REQ'D LONG TAPCONS 2X8 P.T. STAGGERED @ 16" O.C. 2X8\—NOTCH ` JOIST & (4) 3/16"x13/4" WEDGE BOLTS INTO K.O. BLOCK 2x DETAIL 2 1 /4" DETAIL 2 ROWS INTO MASONRY 3-1 /4" DETAIL +5^ WEB AT FIRST 2 COURSES E BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC FIL LED CELL PER FOUNDATION PLAN FILLED CELL INSTALLATION(H'�RETROFIT FOR MISSING EMBEDDED STRAP SCALE: N.T.S. SS SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S- SCALE: N.T.S. SS 2x8 P.T. BUCK -CONNECT TO BLOCK SECTION UPLIFT CAPACITY = 945 #FOR 1 STRAP W/ 1/4" x 3 1/4" TAPCON ( 1 1/4" MIN. A -A = 1890 #FOR 2 STRAPS FILL ist4 COURSES EMBEDMENT INTO BLK.) 1/4" MAX SOLID W/GROUT tr 2'-0" 8" 1-PLY PRE-ENGINEERED TRUSS 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. 1/4" x 3 1/4" TAPCONS BLOCK HEADER ARCH BLKG. & BUCK USP RT16M W/ (8) NA11 NAILS & (6) 4" x 21" TAPCONS 1/2" DRYWALL * (IF TRUSS IS 2 PLY INSTALL USP HTWM16 W/ (6) 8d NAILS AT 8' O.C. AT BUCK 10d NAILS x 11' NAILS AND 2 x 8 45^ DIAGONAL (4) 10d NAILS INTO LEAVE A CUT OUT IN O.S.B. ON THE (4) 4" X 1 4" WEDGE BOLTS [ (1) STRAP = 1225 # , 2450#]) BRACE(S) 2 x 8 BRACE/ BLKG. INSIDE TO ALLOW FOR INSULATION (2) STRAPS 7/16 OSB TO BE INSTALLED BOND BEAM OR CAST FOR OVERHANGS BETWEEN OVER 1 1/2" BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR POLY -CELL IN THIS AREA 2 x 8 45 DIAGONAL BRACE AT EA. IN PLACE BEAM CONTACT ENGINEER OF RECORD FOR FURTHER INSTRUCTIONS. SCRIBE (NOTCH) BACKSIDE TO FIT ARCH (4) 10d NAILS INTO 2 x 8 FACE OF ARCH W/ (3) 10d NAILS AT EA, END RETROFIT TRUSS DETAIL OVERHAN CONNECT W/ 8d NAILS BRACE/ BLKG. N.T.S. a: INSTALL WDW. SCREW ANCHO 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB INTO ARCH BLKG. PER ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8 PROVIDE TAPCON WITHIN RETROFIT WALL OVERHANG DETAIL (NTS) 4" MIN. OF BRACE INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU 2 X 4 #2 SYP SCAB TO SIDE OF TRUSS AS SHOWN FOR O.H. UP TO Z-6" FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH * DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. START OF ARC IF TRUSSES USED) W/ (3) #6 X 4%" WOOD NOTE: FOR OVERHANGS LESS THAN 3/4"- NO REPAIR REQ'D. 4' MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY (2) 10d NAILS @ 8" O.C. X 0�FR TO TRUSS TOP CHORD ARCH DETAIL WALL USE (3) 1/4" X 3 1/2" TAPCONS AT 16" Nq/y SCALE: N.T.S. SS O.C. 12 + + F/� + CTH PLYWOOD SHEATHING 1 r-011 5'-0„ JACK TRUSS PROVIDED BY SEE TRUSS COMPANY OR PLAN _ 2x6 #2 SYP @ 24" O.C. + + + INISH FLO QR AdLf 2 x 8 BUCK - CONNECT TO BLOCK SECTION + + BLOCKING AS WITH 1/4" x 3 1/4" TAPCON (1 1/4" MIN. B_B ROOF SHEATHING ATTACHED + REQUIRED > e /4" MAX EMBEDMENT INTO K.) PER NAILING SCHEDULE ALL TO SUPPORT ° • • ° o.. #5 BAR 2' 0" 8 TRUSS + + SOFFIT .D > 10„ P C ° RED W/ BLOCK HEADER SOLID BLKG. AT TOP BTWN, ARCH -1 NAILS + ° ,y 90' Ii ° N TOP 1 X 4 FURRING BLKG. &BUCK 2X O USP RT3A 2X6 TO 2X4 2X4 SYP ► ®• ' ° .' . .� o KNOCKOUT / iv EACH TRUSS > — ° CHAIR BLOCK 8d NAILS @ 8" O.C. AT BUCK -- ° 2 x 8 VERT. W/ (2) 10d NAILS AT EA. END PROVIDE 2x •� • CONNECTOR '® _ MONO FOOTING - �- ' a PROVIDE 2 x 8 DIAG. BRACE BT VERT. BRACES WHEN HGT. OF BRACE EXCEEDS 24" PROVIDE (2) MIN. TAPCON AT EA. SIDE BUCK - (1) WITHIN 4" CONT. W/ (3) 12d NAILS JACK TRUSS PROVIDED BY TEL SEE LINTEL LIN SIZE AND REINF. PER PLAN __ AND SECTION DETAILS LEAVE A CUT OUT IN O.S.B. ON T MIN. OF START OF TRUSS COMPANY OR 2x4 SEE CLEAN FILL 2 x 8 VERT. BRACE(S) INSIDE TO ALLOW FOR INSULATION ARCH #2 SYP @ 24" O.C. ENTER SO IT DIRT TO BE INSTALLED 00, BUILT UP PLWD. BUCK - 4'-0" MAX SEE PLAN PRECAST LINTEL STANDARD o .e, . °r99 SCRIBE (NOTCH) BACKSIDE ) 7/16" OSB ARCH PANEL 2X4 SYP #2 CONT. (MATCH TRUSS DEPTH SEE ELEVATION o • #5 BAR IN _ HOOK N TO FIT ARCH CONNECT W/ IF TRUSSES USED) W/ (2) #6 X 4'/2' WOOD FOR OVER HANG FILLED CELL , • - • - • • -. - • • 8d NAILS 2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) START OF ARC SCREWS @ 16" O.C. MAX. OR IF MASONRY (MAX. 4'-0") • , • • '• �., • • •, INSTALL WDW, SCREW BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL EQUAL 4' MAX. RAD. WALL USE (2) 1/4" X 3 1/2" TAPCONS AT 16" • ° - ��. .- .• .• .- .• .- .• ANCHOR INTO ARCH BLKG. THRU OSB INTO 2 x 8 O.C. PER INSTALLATION DETAILS B-B ARCH DETAIL rK SECTION @ ENTRY L SECTION @ROOF EXTENSION M STEMWALL FOOTING SIZE AND REINF, PERLAN AND STEMWALL MONO TO STEMWALL FOOTING SCALE: N.T.S. SS SCALE: 3/4" = V-0" SS SCALE: 3/4" = V-0" SS SECTION DETAILS SCALE: 3/4" = V-0" GLASS BLOCK INSTALLATION NOTES NOTE: IF RETROFIT FILLED CELL CONDITIONS A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY EXCEED (3) PER PROJECT, CONTACT ENGINEER OF RECORD AT LEAST 2 HOURS BEFORE PLACING MORTAR. B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP FOR ADDITIONAL INSTRUCTION. EXTENDS TO SILL. C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. MASONRY WALL. SEE PLAN FOR EXISTING BOND BEAM. REINFORCING. PROVIDE LOWER D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS HOOKED DOWEL 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE SEE SHEET D2 AND DRILL 3/4"X6" MIN. HOLE TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP FLOOR PLAN FOR A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL MORE INFO SET BAR IN EPDXY REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR HTT16 W/ (18) - 16d NAILS TO CAP TO PREVENT LEAKAGE BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER W.W.M. AT PERIMETER COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. 1/4" EXPANSION BOLT (2 WHERE THIS CONDITION STUDS & (1) - 5/8" DIA. ALL #5X6' EMBEDDED INTO E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 a. PANEL PER ANCHOR) T #5 BARS IN. 3"CONTOCCURS TOP WITH MIN. 3" THREAD ROD EPDXIED W/ SIMPSON SET EPDXY MIN. z EXISTING BOND BEAM IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. THE SAME SPACING ( REINFORCING COVER 6'-0" � 5" EMBEDMENT & 3" MIN. ` a Cl) SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER F.F. � FILL CELL FULL HEIGHT W/ OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP EDGE DISTANCE LL w NON SHRINK GROUT. LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE ° p U THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL u v a A REINFORCING AS FOLLOWS: I III Hf fita I-III=III=III=1_TI=III; 1 PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. SEALANT ;.= ° ° I=III—T==III-III- g = — — "—' F- Q -' 5X6' EMBEDDED INTO PRESS PANEL REINFORCING INTO PLACE. " ' 6 MIN. LAP SPLICE W/ — — — EXISTING FOOTING 2 #5X6 IN CONC. COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL REINFORCING PANEL III-III=I N FILLED CELL SMOOTH. DO NO FURROW. o ° DRILL 3/4"X6" MIN. HOLE F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT u �I I —I I- GRADE o. —I i �- SET BAR IN EPDXY FURROW. MAINTAIN UNIFORM JOINT WIDTH. 6" MIN. LAP p ° I O G SET SUCCEEDING COURSE OF BLOCKS. SPACE T HEAD C S S C A OF PANEL AND JAMBS MUST SPLICE - ° REMAIN FREE OF MORTAR, NOTE: M z H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS SEE GLASS BLOCK INSTALLATION NOTES. o ' TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT , ' \tea ,4" SAW CUT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL \ ' (2) #5 REBAR. MIN. 3" TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 16"MIN. COVER EA. WAY A SECTION 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN EXISTING FOOTING GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. 1 SCALE: N.T.S. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE SECTION AT DEEP MONO FOUNDATION RETROFIT FOR MISSING MSTAM STRAP MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. RETROFIT FILLED CELL DETAIL K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAYBE INSTALLED IN ANY OPENING. SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" FOR WIND SPEEDS UP TO 110 MPH", PER PITTSBURG CORNING RECOMMENDATIONS FOR SCALE: N.T.S. INSTALLATION OF GLASS BLOCK. CD M O 'off Q � O u� Q)(0 n •U � vI r-o OM o U CONmL.0 r E co@ M m a M --O O`8o U t LL W o, ai to a- o O - Q m u7 V O Q O A� N C B D C N°•o% v m —r - 11r ADt g.��', NZ N o 90 �� 6 M n lit, W LH � Ll. � �T �F N �..ep 4 N ^'_ Ny�C o f� V o LL W ¢mow ��/a�llli4°4`` v ❑❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 ON Z O 7LJ o r>—i M O Q _� L1� a � Q Q) —Ln U a00 Z§ E:� H w W W d- oZ Eo w z a z f� w<ce UzC)5 U Z U Z Q V. O w Z Ov W N mZo oV) zZ >0 ¢ rl Z 0 5 ca 8 O > U Cn J (� o_ W Lu fV a a Z¢o¢ W -Z J a ¢ Z w N � w W ZZ =Q�� J rl LU v C) z � Y ¢ M Q Z Ceuo ¢,Z Z o, Z O Z = J Q ¢ z z .-I a v7 SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION NO. 10 SHEET NO. Sis CROSS BRACING DETAIL (TYP.) SCALE: 1/2" = 1'-0" TRUSS NOTES: CONV. FRAMED RIDGE 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2002 MAY BE NAILED (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 1 WHEN BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS—i COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" O.C. MAXIMUM. 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D NAILS AT EACH TRUSS INTERSECTION. 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS 2X4 BLOCKING 2X4 DIAGONAL AT V-0" O.C. BETWEEN EA. TRUSS MAX & EACH END ALTERNATE , w DIRECTION TYP. ----L WOOD TRUSS A TYP. WOOD TRUSS BLOCKING DETAIL SCALE: 1 /2"= V-0" WOOD WALL OR TRUSS. SEE PLAN STRUCTURAL SHEATHING ATTACHED PER NAILING SCHEDULE VARIES W/ ROOF SLOPE 2X4 CONT. W/ (2) 16d COMMONS NAILS EACH STUD TYP. T&B TRUSS OR ROOF SYSTEM SHEAR TRANSFER EXTERIOR. WALL SCALE: 3/4" = V-0" CB DB- TYP. HAND FRAMING ABOVE TRUSS 2X4 STUDS & PLATES AT 2'-0" O.C. EACH DIRECTION TYP. U.N.O. - 2x8 BLKING. NAILED @ EACH SIDE w/ (3) 12d NAILS WHEN REQUIRED w/ (2) USP HTW20 W/ (14) - 10d X 1 1/2" EACH TB I PRE-ENG. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — CHORD AT ALL HAND FRAMED AREAS TYP. DIAGONAL - AT 8'-0" MAX TRUSS SEE ROOF PROVIDE 2X4 MIN. BLOCKING AT W PLAN SHEATHING Q OF HIP/RIDGE, TYP.BETWEEN TRUSSES W/ (2) 12D NAILS EACH END TO TRUSS TOP CHORD 2X4 BLOCKING TYP. BETWEEN TRUSSES TRUSS SECT. A -A �A G.T. ADD 2X4 ALONGSIDE TOP CHORD WHEN REQ'D TO PREVENT PLYWOOD SPAN FROM EXCEEDING JACK MAX 24" SPAN (EITHER USSES HIP SIDE OR BOTH IF REQ'D) 01 G.T (2) 12D NAILS AT 12" O.C. MAX HIP/RIDGE BLOCKING DETAIL r2 SCALE: 1/2"=V-0" VERTICAL SCAB 2 x 6 #2 SPF 48" O.C. W/ (4) 10d TOP & BOTTOM OR USP RT7 OR HCLR/LL W/ 8 - 8d IN PLACE OF (4) 10d COLLAR TIE EVERY 3rd RAFTER 2x4 SPF 2 (2) #7X 3-1/2" WOOD SCREW EACH TRUSS OR USP RT7 @ 48" O.C. BEVEL CUTS (OPTIONAL) 2x8 #2 SPF RIDGE BEAM 2x6 #2 SYP RAFTERS FOR SPANS 4FT TO 8FT 2X4 RAFTERS FOR SPANS LESS THAN 4FT @ 2-0"O.C. MAX. w/ (3) 10d COMMON TOENAILS TO RIDE BEAM 2X4 CONT. AT—/ CONC. MASONRY T & B CHORD STEEL OR WOOD BEARING SUPPORT A —A ALTERNATE BLOCKING DETAIL a@ INTERIOR BEARING PROVIDE BLOCKING AT ALL TRUSS BEARING SUPPORT WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT OL VARIES IT 2X4 #2 SPF BRACING @ 16" O.C. W/ (4) 12d TOENAILS TO TOP PLATE & (2) 12d END NAILS TO TRUSS BOTTOM CHORD SCALE: 1/2" = 1'-0" ROOF SHEATHING ATTACHED PER NAILING SCHEDULE 1 —� COMMON TRUSSES. SEE TRUSS PLAN MIN. (2) 2x4 FOR CONNECTION SPF TOP INFORMATION. PLATE OILVARIES SEE PLAN FOR WALL LOCATION MIN. 2x4 #2 SPF STUDS @ 16" O.C. W/ EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE & (3) 12d TOENAILS TO SEE PLAN FOR f PLATE BELOW TOP OF WALLA. ; MIN. 2X4 #2 SYP P.T. PLATE eon W/ 1/2"X8" EPDXY ANCHOR MASONRY WALL SEE @ 3" FROM EACH END & PLAN FOR MORE o 16" O.C. MAX. INFO. SECTION @ ENTRY 8 SCALE: 3/4" = 1'-0" USP LSTA18 CENTERED @ SPLIT TO TIE BEAMS TOGETHER USP HD4101F BUCKET SEE ROOF PLAN FOR MORE INFO (2) 2x8 #2 SYP W 7/16" O.S.B. FLIT PLATE TOP @ TI BRG. TYPIC WALL NOTE: PENDING BEAM BEARING LOCATION, THE BEAM CAN SIT ON TOP OF COLUMN W/ (2) HTW20 STRAPS USP JUS46 OR JUS461F BUCKET TO COLUMN SUPPORT COLUMN BUILT-UP (2)-2x4's OR 4x4 W/ (2)-10d NAILS @ 8" O.C. EACH PLY (SHOWN AS 4 x 4) (2) USP HTA20's w/(10)-10d x 1 1/2 EA. TO COL. ALT: (2) USP MSTAM36 STRAPS CENTERED w/(13)-10d NAILS Ea TO COL. TIE BEAM BEAM @ RAISED ENTRY MASONRY WALL 4 SCALE: 1/2" = 1'-0" L.SEE PLAN L. FOR CANT. SEE FLOOR PLAN FOR COLUMN SIZE & BASE —7/16" OSB FLITCH PLATE SEE FLOOR PLAN CONNECTION INFO REQ'D ONLY WHEN FOR COLUMN SIZE INDICATED ON BM. & ADDITIONAL INFO. 7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR SCHEDULE/PLAN REQ'D ONLY WHEN COLUMN SIZE & BASE OPTION A INDICATED ON SC EDU E/PLANM OPTION B CONNECTION INFO OPTION C COMMON BM. TO POST ATTACHMENT A SEE ROOF PLAN FOR BEAM SIZE & SCALE: 3/4"=V-0" BM. SPLICE OVER CONNECTION INFO. CENTER OF POST USP ST18 TYP. U.N.O. SEE FLOOR PLAN FOR COLUMN SIZE & ADDITIONAL INFO. (WOOD COLUMN SHOWN) 2x4 STUDS W/ USP SPT22 @ BASE SEE J/S6 FOR MORE INFO. A A SEE PLAN FOR TOP OF BEAM IV SEE PLAN FOR CANT. IF INDICATED CORNER SEE FOUNDATION PLAN FOR MORE INFO 5" COMMON BM. ATTACHMENT SCALE: 3/4"=V-0" EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE 2x4 BASE PLATE W/ USP LSTA30 OR MTW12 TO FLOOR GIRDER BELOW @ 16" O.C. 16" FLOOR SYSTEM FLOOR GIRDER SEE PLAN FOR SEE PLAN FOR DIRECTION CONNECTION SECTION a@ FLOOR CONNECTION 22 SCALE: 3/4" = 1'-0" SEE 1/S5 FOR ADDITIONAL OUTLOOKER INFO. igi TRUSS 1/2" PLYWOOD (2) 16d NAILS TO EACH COMMON TRUSS/ FRAMING TYP TOP & BOTTOM MIDDLE [— SEE PLAN FOR 8d NAILS AT VALLEY TRUSS 4" O.C. INFO. MASONRY WALL BELOW: USP '<. HTA16 @ 4'-0" O.C. TO GABLE MASONRY WALL TRUSS BEAM BELOW: USP OR BEAM HTW20 @ 4'-0" O.C. TO GABLE SEE TRUSS PLAN as TRUSS COMMON TRUSS SEE ROOF PLAN FOR CONNECTION SECTION AT HIP GABLE 12 SCALE: 3/4" = 1'-0" JACK TRUSS (AS SHOWN) OR GABLE END SEE TRUSS LAYOUT CLIP EACH TRUSS (SEE ROOF PLAN FOR TYPE) FRAME OUT TO BLOCK EDGE SEE DETAIL 4/D1 FOR BEAM SIZE EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE 2x SPF #2 AT 16" O.C. rL I BUILDER FRAME RADIUS AS REQUIRED KNEEWALL @ENTRY FRONT WALL 2x4 #2 SYP NAILER. NAIL TO STUDS w/3-16d @ EA. STUD. TOENAIL EA. TRUSS TO NAILER w/3-10d USP JU26 OR IF 2 PLY TRUSS USP JUS26-2 TRUSS TO LEDGER 2X8 #2 SYP CONT. LEDGER w/ (4) 16d NAILS ATTACH NAILS INTO END OF EACH FLOOR TRUSS, 24" O.C. MAX. (AT EACH SIDE OF G.T. INSTALL (4) NAILS EACH SIDE) SCALE: 1/2" = 1'4' ROOF AND EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE SEE 2ND FLOOR WALL SECTION FOR ADDITIONAL INFORMATION SEE FLOOR FRAMING PLAN AND J/S6 FOR MORE INFO. VERIFY WITH PLAN FOR LOCATION AND DIRECTION (IF PARALLE SEE 2/D2 FOR BLOCKING INFO) -MASONRY WALL (TYPICAL) SECTION AT LOW ROOF SCALE: 1/2" = 1'-0" LOW ROOF/WALL SHEATHING ATTACHED PER NAILING SCHEDULE �-- 2x STUDS @ 16" O.C. W/ USP SPT22 @ BASE & SPT24 @ TOP 2x BLOCKING BETWEEN STUDS TO TRUSS W/ (2) 12d TOENAILS EACH END ( BETWEEN TRUSSES (2) 12d NAILS TO EACH VERTICAL STUD) 2x BASE PLATE W/ (2) 12d NAILS @ 16" O.C. ALONG W/ USP MTW12 TO BLOCKING BELOW @ 16" O.C. PLYWOOD FLOORING LOW ROOF TRUSS W/ (2) 2x6 BLOCKING UNDER FLOOR G.T. RAISED BOTTOM CHORD 2nd FLOOR WALL W/ USP SEE PLAN EXTENSION SEE TRUSS JUS24-2 EACH END MANUF. SPEC'S FOR CONNECTIONS TO G.T. SECTION @ BUMP OUT 39 SCALE: 3/4"=1'-0" 1_1"� DETAILS & SECTIONS o O Q O .J CL co O W er, (D a--) w _— a .0 IIJ 0.. E V) ,, � v r— o M O o N M t� F— EO C'MM co 'O M _.._ U O O 0 ,✓U_00 = co •°'' b g Y +J1 O OV d m CL o Q o ! Z 0 y yMnzt ti JF.° 9 a_V_ �9 �j . o , �> k <\ V - Q cL _ ` .. C,.Nc�I � `�Ti••• Jm\\. N To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O CD Z N O �\ r > Ln r O aLI)�_Ln a e Ln r-, Q LL a Q U Qco ru Z �: ry W O W JC:) d' J oZ �o Z, Z� ¢¢ �F W ¢ z ° U Z O O U Z U Z Q = 0 w Z aO�n O�L�LO W O Z F W °Z z= T O ¢ U Z T-4 �-- 5 3 Z) Lu O 0 o 2: L (n v' O > Z U J Q oW ¢se¢r-¢ o J O W x O 6 W U y m J rada N Q o¢o¢ Uj - Z a ¢¢ z N wMZ0 Z LU ul �WOI- =¢LLZ, J r1 LLJ W Q Ln o w o M M ''1 Q z z a�Fo ¢WZ a 2<0 O ,--1 a. cn SCALE: AS NOTED DATE: 2/24/2014 TECH: MJAMES VERSION N0. 10 C SHEET NO. D1 ^' ^ "r') WEATHER ✓E BARRIER & tARILY SECURE WEATHER RESISITIVE BARRIER off TAPE (ASSEMBLED WINDOW) _= HEAD FLASHING TIE-IN INSTRUXTIONS: 1. Cut, fold up & temporarily secure weat THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing installation iMEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under AND WATERPROOFING METHODS TO weather resistive barrier BE USED. 3. Fold weather resistive barrier back over head flashing and seal with tape SELF -ADHERED FLASHING Scale: NTS FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER EXTERIOR SHEATHING REFER TO TECHNICAL LETTER ON CHEMICAL COMPATIBILITY SELF -ADHERED FLASHING WOOD FRAME CONSTR. EXTERIOR SELF -ADHERED FLASHIN SHEATHING BY LAPPING DOWN _� OVER RIM JOIST AND UP WALL BY 6 IN. WEATHER RESISITIVE BARRIER SEAL TOPS OF JOI; UNDER DECKING (SEE DETAIL WP07) ED FLASHING SELF -ADHERED FLASHING NAILING FLANGE 1 DO NOT FLASH OVER 2 BOTTOM NAILING 8 FLANGE SELF -ADHERED FLASHING HALF ROUND WINDOW E AM WEATHER RESISTIVE BARRIER DOOR ROUGH OPENING 3/4%1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING �- SELF -ADHERED FLASHING SUBFLOOR SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING 3/4"-V BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SECTION -A (SEE DETAIL WP02) SELF -ADHERED FLASHING SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK RIM JOIST INSTALL SELF -ADHERED FLASHING JAMB & HEAD FLASHING, SEE FLANGED WINDOW (SEE DETAIL WP01) SELF -ADHERED FLASHING, EXTEND A MINIMUM 6" VERTICALLY FROM BOTTOM OF THRESHOLD SELF -ADHERED FLASHING PATCH Id vSELF-ADHERED FLASHING SELF -ADHERED FLASHING v. 1 2 3" MIN 4 SELF -ADHERED FLASHING ■ SELF -ADHERED FLASHING ■ • FOUNDATION WEEP SCREED DECK JOIST ' OUTSIDE CORNER ' ' • WINDOW UNIT SLOPE 0.3 in : 12.0 in (0.6 cm : 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT. FIN. BUILDING PAPER WIRE LATH Q SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE THROUGH SELF -ADHERED FLASHING SELF -ADHERED FLASHING 51 SCORED RELEASE PAPER (BEFORE FOLDING, SCORE RELEASE PAPER TO EXPOSE ADHESIVE AS SHOWN) SELF -ADHERED FLASHING INSIDE CORNER Ground f`© r`O rO 50, Water Resistant Barrier Lath Sheathing Stucco FLASHING REQUIREMENTS R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. with A TM D 22 for Type 1 felt or R703.2 Weather resistant sheathingpaper. One layer of No.15 asphalt felt free from holes and breaks complyingS 6 0 P P Y P YP other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1 Exception: Omission of the water -resistive barrier is permitted in the following situations: 1. In detached accessory buildings. 2. Under exterior wall finish materials as permitted in Table R703.4 3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following or other approved method: 1.1 The fenestration manufacturer's written flashing instructions. 1.2 The flashing manufacturer's written installation instructions. 1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMANVDMA 250. 1.4 In accordance with the flashing method of a registered design professional. 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. 3. Under and at the ends of masonry, wood or metal copings and sills. 4. Continuously above all projecting wood trim. 5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6. At wall and roof intersections. 7. At built-in gutters. R703.6.2.1 Weep Screeds A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. SELF -ADHERED FLASHING PRODUCTS DETAILS TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 Detail Instructions Refer to the number marked as #Oin each detail that corresponds to the numbered items in the list of instructions below: 1. Install self -adhered flashing in order as shown by numbers 2. Install flashing and weather resistive barrier to form water shedding laps 3. Self -adhered flashing can be substituted for building paper 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation and to minimize scoring cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner 8. Mechanically fasten as necessary Cement Plaster in accordance with ASTMC926 over wood 2nd floor Cement Plaster over block 1 st floor 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper -7/16" O.S.B. sheathing - Metal Flashing Weep Screed Installed As Per Manufact. Specs. Maintain Bottom of Weep Screed 1 1/2" to 2" Above Roof Sheathing Note: The building paper and metal lath must be installed over the top of the weep screed. WEEP SCREED DETAIL NOT USED ■ NOT USED ■ NOT USED ■ SCALE: NOT TO SCALE 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper 7/16" O.S.B. sheathing Stampede or similar cauk bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish All inside and outside corner will need to be miter cut and caulked all butt joints need to becaulked using Stampede or sim. caulk for all UI - o Q ID Z WO (D nN �✓ cn i--J LLI M �U - OLU 0-1E V) 0 � � o0 mr U Lu a) co C' f6 M F- E -O 2'O M O`oo _ U ��co a i c0 CL o O Y QCL rn LO rnQo Al0 BID, N C B D C ti N N N �y ooC oN o00 Z o ZW�C) ,�� Z '"= u C. Lu W �' N ,N Q' V -. n_ ° - Lu �i L i O -o U)rn y o Q Z 7 C) O 0 N� a� p ZHY IL m m g- Q d0 Jo W N a M U U ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z cV O av r-, >V)rno ¢__Ln .L � " V) n � o ¢ QL Q U Q cc) E Z ?> ru W O WJ� �Z o 3Z w� zd Z a 6¢oc Z O U Z Lu w ��Wz w U ¢w2o J O N W mzo Q �w oZ Z z ao LLJ�Z O LL 3 0 O o o T-I O O Z J Q U CO- CL � OLL N ¢o6 2 0 ¢ i;�m� Zoo zi�rf�V J Q ¢ v Q ~~$ H W Z N woo �dwo� W J L0 �--I W �aLL� �, o LLI ¢ o w 0 M M ¢ Z~o ¢Cz �--I Z a U) V)z m O ^ g = Q� rn •-t a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAMES VERSION No' 10 SHEET NO. WP USP Stock No. A3 Florida Statewide Product Approval No. FL17244.1 Evaluation Report Basis ESR-3455 Simpson Stock No. A23 Florida Statewide Product Approval No. FL10446.2 Evaluation Report Basis ESR-2606 HD210-2 FL17232.3 ESR-3445 HU210-2 FL10655.20 ESR-2549 HD212-2 FL17232.3 ESR-3445 HU212-2 FL10655.23 ESR-2549 HD216 FL17232.3 ESR-3445 HU216 FL10655.29 ESR-2549 HD216-3 FL17232.3 ESR-3445 HU216-3 FL10655.29 ESR-2549 HD26 FL17232.2 ESR-3445 HU26 FL10655.31 ESR-2549 H D28-2 FL17232.3 ESR-3445 H U28-2 F L 10655.34 ESR-2549 HD410 FL17232.4 ESR-3445 HU410 FL10655.44 ESR-2549 H D412 FL 17232.4 ESR-3445 H U412 F L 10655.45 ESR-2549 HD610 FL17232.4 ESR-3445 HU610 FL10655.51 ESR-2549 HD0410 FL17241.5 ESR-3444 HUCQ410 FL11468.11 SIM200804 HGA10KT FL17236.6 ESR-3448 HGA10KT FL11470A SIM200803 HGAM10KT FL17699.1 Evaluation Report HGAM10KT FL11470.4 SIM200803 H HCP2 F L 17236.7 ESR-3448 H CP2 F L 10447.2 ESR-2551 HTA16 FL17680.2 Evaluation Report HETA16 FL11473.5 SIM200802 HTA20-18 FL17680.2 Evaluation Report HETA20 FL11473.5 SIM200802 HTT16 FL17324.1 Evaluation Report HTT16 FL11496.1 ES-0130 HTT45 F1_17324.1 Evaluation Report HTT22 FL11496.1 ES-0130 HTT4 FL17219.2 ER-0200 HTS16 FL10456.22 ESR-2613 HTT5 FL17219.2 ER-0200 HTS20 FL10456.23 ESR-2613 HTW16 FL17244.8 ESR-3455 HTS24 FL10456.24 ESR-2613 HTW20 FL17244.8 ESR-3455 HTS30 FL10456.26 ESR-2613 HTW24 FL17244.8 ESR-3455 HTSM16 FL11473.t 1 SIM200802 HTW30 FL17244.8 ESR-3455 HTSM20 FL11473.11 SIM200802 HTWM16 FL6223.2 Evaluation Report HGT2 FL10456.18 ESR-2613 HTWM20 FL6223.2 Evaluation Report HGT3 FL10456.19 ESR-2613 HUGT2 FL6223.3 Evaluation Report HUS210-2 F1_10655.92 ESR-2549 HUGT3 FL6223.3 Evaluation Report HUS212-2 FL10655.93 ESR-2549 HUS210-2 FL17232.7 ESR-3445 HUS26 FL10655.94 ESR-2549 HUS212-2 FL17232.7 ESR-3445 HUS28 FL10655.96 ESR-2549 HUS26 F1_17232.7 ESR-3445 HUS28-2 FL10655.97 ESR-2549 HUS28 FL17232.7 ESR-3445 LU24 FL10655.103 ESR-2549 HUS28-2 FL17232.7 ESR-3445 LU26 FL10655.104 ESR-2549 JL24 FL17232.8 ESR-3445 LUS210-2 FL10655.107 ESR-2549 JL26 FL17232.8 ESR-3445 LUS24 FL10655.109 ESR-2549 JUS210-2 FL17232.12 ESR-3445 LUS26 FL10655.111 ESR-2549 JUS24 FL17232.11 ESR-3445 LUS26-2 FL10655.112 ESR-2549 JUS26 FL17232.12 ESR-3445 LUS28 FL10655.113 ESR-2549 JUS26-2 FL17232.12 ESR-3445 LUS46 FL10655.118 ESR-2549 JUS28 FL17232.12 ESR-3445 LEG3 FL10667.71 ESR-2615 JUS46 FL17232.12 ESR-3445 MST60 FL10852.7 ESR-2105 KLEG3 FL17241.15 ESR-3444 LSTA12 FL10852.4 ESR-2105 KST260 FL17244.15 ESR-3455 LSTA15 FL10852.4 ESR-2105 LSTA12 FL17244.18 ESR-3455 LSTA18 FL10852.4 ESR-2105 LSTA15 FL17244.18 ESR-3455 LSTA24 FL10852.4 ESR-2105 LSTA18 FL17244.18 ESR-3455 LSTA30 FL10852.4 ESR-2105 LSTA24 FL17244.18 ESR-3455 LSTA36 F L 10852.5 ESR-2105 LSTA30 FL17244.18 ESR-3455 LTT19 FL11496.3 ER-130 LSTA36 FL17244.18 ESR-3455 LTT20B FL11496.3 ER-130 LTS 19 F L17219.3 ER-0200 LTTI31 F L 11496.3 E R-130 LTS20B F L 17219.3 E R-0200 LTS 12 F L 10456.29 ESR-2613 LTT131 FL17219.3 ER-0200 LGT2 FL11470.7 SIM200803 LTW12 FL17244.8 ESR-3455 LS30 FL10446.15 ESR-2606 LUGT2 FL17240.2 ESR-3447 A34 FL10446.3 ESR-2606 MP3 FL17244.22 ESR-3455 LTP4 FL10446.19 ESR-2606 MP34 FL17244.23 ESR-3455 LS50 FL10446.16 ESR-2606 MP4F FL17244.24 ESR-3455 WMI416 FL1 D667.86 ESR-2615 MP5 FL17244.22 ESR-3455 MSTA12 FL10852.8 ESR-2105 MPH3516 FL17240.3 ESR-3447 MSTA15 FL10852.8 ESR-2105 MSTA12 FL17244.18 ESR-3455 MSTA18 FL10852.9 ESR-2105 MSTA15 FL17244.18 ESR-3455 MSTA24 FL10852.9 ESR-2105 MSTA18 FL17244.18 ESR-3455 MSTA36 FL10852.9 ESR-2105 MSTA24 FL17244.18 ESR-3455 MSTC40 FL10852.11 ESR-2105 MSTA36 FL17244.18 ESR-3455 MSTC52 FL10852.11 ESR-2105 MSTC40 FL17244.26 ESR-3455 MTS12 FL10456.33 ESR-2613 MSTC52 FL17244.26 ESR-3455 MTS16 FL10456.34 ESR-2613 MTW12 FL17244.8 ESR-3455 MTS18 FL10456.35 ESR-2613 MTW16 FL17244.8 ESR-3455 MTS20 FL10456.36 ESR-2613 MTW 18 F L17244.8 ESR-3455 MGT F L 11470.9 SIM200803 MTW20 FL17244.8 ESR-3455 MBHA3.56/11.25 FL10866.12 ESR-2616 MUGT15 FL17240.5 ESR-3447 MBHA3.56/16 FL10866.12 ESR-2616 NFM35X12 FL578.2 Evaluation Report HDU2-SDS2.5 FL10441A ESR-2330 NFM35X16U FL578.3 Evaluation Report GLTV3.516 FL10667.8 ESR-2615 PAU44 FL17239.13 ESR-3449 FGTR FL11473.2 SIM200802 PAU66 FL 17239.13 ESR-3449 C S 16 F L10852.1 ESR-2105 P HD2A F L 17219.4 E R-0200 H 1 FL 10456.5 ESR-2613 PHXU3516 FL17241.20 ESR-3444 H10 FL10456.6 ESR-2613 RFUS FL6223.5 Evaluation Report H10-2 FL10456.7 ESR-2613 RS150 FL17244.27 ESR-3455 H10A FL10456.E ESR-2613 RT15 FL17236.11 ESR-3448 H3 FL10456.13 ESR-2613 RT16-2 FL17236.10 ESR-3448 H4 FL10456.14 ESR-2613 RT16A FL17236.10 ESR-3448 H5 FL10456.15 ESR-2613 RT3A FL17236.11 ESR-3448 H2.5 FL10456.11 ESR-2613 RT4 F1_17236.11 ESR-3448 H2.5A FL10456.12 ESR-2613 RT5 FL17236.11 ESR-3448 H8 FL11470.3 SIM200803 RT7 FL17236.11 ESR-3448 SPt FL10456.41 ESR-2613 RT7A FL17236.11 ESR-3448 SP2 FL10456.42 ESR-2613 RT8A FL17236.11 ESR-3448 SP4 FL10456.43 ESR-2613 SPT22 FL17244.30 ESR-3455 SP6 FL10456.44 ESR-2613 SPT24 FL17244.31 ESR-3455 SP8 FL10456.45 ESR-2613 SPT4 FL17244.32 ESR-3455 SPH4 FL10456.46 ESR-2613 SPT6 FL17244.32 ESR-3455 SPH6 FL10456.47 ESR-2613 SPT8 FL17244.32 ESR-3455 SPH8 FL10456.48 ESR-2613 SPTH4 FL17244.32 ESR-3455 U24 FL10655.141 ESR-2549 SPTH6 FL17244.32 ESR-3455 HHUS28-2 FL10655.3 ESR-2549 SPTH8 FL17244.32 ESR-3455 HHUS410 FL10655.4 ESR-2549 SUH24 FL17232.14 ESR-3445 HGUS5.25/12 FL11468.11 SIM200804 THD28 FL17232.17 ESR-3445 HGUS414 FL11468.10 SIM200804 THD28-2 FL17232.17 ESR-3445 HDQ8-SDS3 FL10441.1 ESR-2330 THD410 FL17232.17 ESR-3445 MSTAM24 FL11473.19 SIM200802 THD412 FL17232.17 ESR-3445 MSTAM36 FL11473.19 SIM200802 THD612 FL17232.17 ESR-3445 MSTCM40 FL11473.19 SIM200802 THDH414 FL17232.18 ESR-3445 HHETA20 FL11473.9 SIM200802 UGTS3F FL2033.1 Evaluation Report LGT3-SDS2.5 FL11470.7 SIM200803 UPHD8 FL17219.6 ER-0200 LGUM26-2 FL11473.12 SIM200802 PRODUCT APPROVAL SPECIFICATION SHEET As required by Florida Statute 553.842 and Florida Administrative Code 98-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Category/Subcategory Manufacturer Product Description Approval Number(s) Test Pressures 1. EXTERIOR DOORS A. SWINGING ThermaTru Smooth -Star and Benchmark FL15225.5 +67.0/-67.0 psf ThermaTru Premium, Construction Series and Benchmark FL15225.6 +47.0/-47.0 psf ThermaTru Fiber Classic / Smooth Star FL15000.1 +55.0/-55.0 psf B. SLIDING General Aluminum Company Series 420/430 FL15332.1 - FL15332.5 +40.0/-40.0 psf C. SECTIONAL Clopay Building Products Residential WindCode Doors W5 (8X7) FL15279.37 +30.0/-32.0 psf Clopay Building Products Residential WindCode Doors W5 (16X7) FL15279.53 +30.01-30.0 psf Clopay Building Products Residential WindCode Doors W6 (8X7) FL15279.85 +38.01-42.0 psf Clopay Building Products Residential WindCode Doors W6 (16X7) FL15279.102 +37.0/-41.0 psf D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,and 847 Single & Pairs of Doors FL11537.1 N/A (see inst sht) 2. WINDOWS A. SINGLE HUNG General Aluminum Company Series 1550/1570 FL15217.4 - FL15217.5 +50.01-55.0 psf General Aluminum Company Series 1900/1970 FL15217.7 - FL15217.9 +40.0/-50.0 psf B. HORIZONTAL SLIDER General Aluminum Company Series 1580/1590 FL15288.1 - FL15288.2 +40,01-50.0 psf General Aluminum Company Series 1980/1990 FL15288.3 - FL15288.4 +40.0/-50.0 psf C. FIXED General Aluminum Company Series 1550/1570 FL15278.4 - FL15278.5 +40.0/-40.0 psf General Aluminum Company Series 1900/1970 FL15278.7 - FL15278.9 +40.0/-50.0 psf D. MULLION General Aluminum Company 1445, 5347 and 5547 Vertical Mullion FL15333.7 N/A E. OTHER 3. PANEL WALL A. SIDING James Hardie Building Prod. Cemplank Lap Siding and HardiePlank Lap Siding FL13192.1 - FL13192.2 N/A B. SOFFITS Alside Solid and Vented Soffit FL15272.1 - FL15272.2 +70.0/-70.0 psf C. OTHER 4. ROOFING PRODUCTS A. ASPHALT SHINGLES Certain Teed Corporation CT20 (and AR), Landmark 30/40 (and AR), FL5444.1 N/A XT25 (and AR), XT30 (and AR) B. UNDERLAYMENTS Tamko 151b Felt Underlayment FL12328.6 N/A HomeGuard Building Products, Inc ToughSkin Synthethic Undedayments FL21675.1 N/A C. ROOFING FASTENERS NOT USED D. ROOF VENTILATORS Thompson Arch Metal Comp. Off Ridge Vents FL5219.1 - FL5219.3 N/A Florida Metal Products, Inc Vent RV10 FL2075.1 N/A Lomanco, Inc DA-4 Exahust Vent FL17202.1 N/A O'Hagin Manufacturing, LLC O'Hagin's Cloakded Vent Tile FL16588.1 N/A E. ROOFING TILES Boral Tile Villa 900 FL7849.24 - FL7849.26 N/A Boral Tile Saxony 900 FL7849.13 - FL7849.16 N/A F. OTHER 5. SHUTTERS A. STORM PANELS Global Protection Products Galvanized Steel Storm Panels FL15076.1 - FL15076.2 N/A Global Protection Products GPP Fabric Shutter Series 2000 FL15088.1 N/A Town and Country Industries Safety Edge Storm Panels FL12856.1 +54.0/-54.0 psf All American Shutters Galvanized Steel Storm Panels FL17869.1 N/A 6. STRUCTURAL COMPONENTS A. WOOD CONNECTORS/ USP Structural Conn. see chart ANCHORS Simpson Strong -Tie see chart B. TRUSS PLATES ITW Building Components Alpine Truss Plates FL1999.1 - FL1999.4 N/A MiTek Industries, Inc. Truss Plates FL2197.1 - FL2197.5 N/A C. ENGINEERED LUMBER Boise Eng. Wood Prod. Versa -Lam SP F1_1644.1 N/A Boise Eng. Wood Prod. Wood I-JoistsALLJOIST FL1645.1 N/A Weyerhaeuser Engineered lumber -TJI FL1630.1 - FL1630.11 N/A Weyerhaeuser iLevel Rim Board, LVL, PSL, LSL FL6527.1 - FL6527.4 N/A D. MATERIAL Cast -Crete Corp. High Strength Concrete Lintels FL158.1 N/A Commercial Concrete Products, Inc. High Strength Concrete Lintels FL1774 N/A Powers Steel, Inc. PS1box8LT, PSbox8LT(5-5/8) FL5450.1 N/A Powers Steel, Inc. PowerBOX8 Lintels FL11383.1 N/A The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I understand these products may have to be removed if approval cannot be demonstrated during inspection. APPLICANT SIGNATURE DATE N C/) C6 O N r L L O O .CM U O Cn N O O O O O O U_ O > O Q -0 E Z W cu > O > LL 0_ O Q U O L W V M m Q O L W Z Z Q J SHEET NO. PA 1.0. O cn Ca N �.., L L O O = co A Florida Department of Business & Professional Regulation Page 1 of 2 Florida Department of Business & Professional Regulation Page 1 of 1 •r•e� 0 '^ �f ♦ }� Building Codes and Standards 1/92017 Building Codes and Standards irsrzo,7 �♦ CU •� Florida Department of Business & Professional Regulation Page 1 of 2 nW V Product Approval Application Detail Product Approval Application Detail Building Codes and Standards 1/9rz017 O •L L FL#15225-R3 FL#15000-R2 Product Approval Application Detail t� O - Code Enti or Date Date Date Pending Date Code Entityor Date Date Date Pending Date FL#15332-R3 Products O j Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Tvpe Versio Manufacturer Contact Engineer &License Validated By Validated Submitted FBC Approval Approved Status O Revision 2014 Therma-Tru Corporation Rick Wright National Accreditation & Ryan J. King, P.E. 06/28/2015 06/13/2015 07/05/2015 Approved Revision 2014 Therma-Tru Corporation Rick Wright Lyndon F. Schmidt, P.E. Ryan J. King, P.E. 06/28/2015 05/29/2015 07/05/2015 08/19/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Design •�_ O Category: Exterior Doors (419) 298-1740 Management Institute (813) 767-6555 Category: Exterior Doors (419) 298.1740 PE-43409 (813) 767.6555 Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure a) L L_ Subcategory: Swinging Exterior Door Assemblies rickw@rwbldgconsultants. SubCategory: Swinging Exterior Door Assemblies rickw@rwbldgconsultants. 4 SERIES 420 ALUMINUM SGD REINFORCED SERIES 420 ALUMINUM SGD REINFORCED OX, 12131/2017 No Yes No N/A U) U) O CU l_ Compliance Method: Certification Mark or Listing com Compliance Method: Evaluation Report from a com XO, XX 96"x96" _� �F- �+ Q FL#15225-R3 Products Florida Registered Architect or a Licensed Florida 5 SERIES 420 ALUMINUM SGD REINFORCED SERIES 420 ALUMINUM SGD REINFORCED XXX 12/31/2017 No Yes No N/A � Q Professional Engineer 143"x96" •� Quality Assurance Approved for Use Approved for Use Impact Design 7 SERIES 420 REINFORCED ALUMINUM SGD SERIES420 REINFORCED ALUMINUM SGD OXO 12/31/2017 No Yes No N/A Seq # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15000-R2 Products 146"x96"a 5 e. &q and "Benchmark by and Opaque and Glazed Fiberglass Door with 12/31/2021 No Yes No NIA 8 SERIES 430/440 ALUMINUM SGD SERIES 430l440 ALUMINUM SGD XXX 12/31/2017 No Yes No N/A a-Tru&oth-Star"a Therms-Tru"a an ou and without Sidelites. and Quality Assurance Aporoved for Use Approved for Use Impact Design 143"x80" NON -REINFORCED 6 f. "Premium Series"a, "Construction and Glazvvinged eel Doorswing 6/8 and 8/0 Opaque and Glazed Steel Door with 1?J31/2021 No Yes No N/A Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 9 SERIES 430/440 REINFORCED ALUMINUM SGD SERIES 430/440 REINFORCED ALUMINUM SGD 12/31/2017 No Yes No N/A Series"a and ",Benchmark by Therma-Tru"a Transoms. With and without Sidelites. Inswing and 1 a. ",Fiber-Classic" or "Smooth-Star" 6'8 "Non- Impact" Opaque Fiberglass 12/31/2018 Yes Yes No N/A XXX 143"x96" with Transoms OutsMng Door with &, without Sidelite(s) - Outswing (X, OX or XO, OXO, XX, OXXO Configurations) Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 2 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/9/2017 LU FL#15279-R4 Building Codes and Standards 1110rz017 Product Approval Application Detail Code Type Versio manufacturer Entity or Contact Engineer & License Validatedv Date Date Validated Submitted Date Pending FBCApproval Date Approved Status Product Approval Application Detail Revision 2014 Clopay Building Products Company Mark Westerfield Intertek Testing Services NA, Gary Pfuehler 06/12/2015 03/19/2015 06/21/2015 FL#15217-R4 Approved FL#11537-R6 Code Entity or Date Date Date Pending Date Category: Exterior Doors (513) 770-6062 Inc. (513) 519-6566 Tvpe Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Statusnj SubCategory: Sectional Exterior Door Assemblies mwesterfield@clopay.com Code Enti or Date Date Date Pending Date Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 06/3012015 06/25/2015 07/06/2015 08/19/2015 Approved Compliance Method: Certification Mark or Listing Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Revision 2014 CURRIES Division of AADG, Inc Nelson Kraschel ILL LLC Ted Berman, PE 07/21/2015 07/21/2015 07/27/2015 Approved SubCategory: Single Hung bsitiinger@miwd.com FL#15279-R4 Products Category: Exterior Doors (641) 423-1334 (305) 868-4707 Compliance Method: Evaluation Report from a Quality Assurance Approved for Use Approved for Use Impact Design SubCategory: Exterior Door Components nelson.kraschel@doorgro Florida Registered Architect or a Licensed Florida Sea # Product Model Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Compliance Method: Certification Mark or Listing up.com Professional Engineer 37 037 W5-09 PAN-21`151: 84A, 94, 73, 75, 1500, 190, 76, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/21/2028 No Yes No +30 PSF/-32 FL#11537-R6 Products FL#15217-R4 Products 76V, 4RST, 4RSF, 6RST, 6RSF, 2RST, 48, 42, 55, 488, WINDCODE®, W5 Garage Door PSF 42B, 55S, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, Quality Assurance Approved for Use Approved for Use Impact Design Quality Assurance Approved for Use Approved for Use Impact Design EDSS, ED5SV Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 607, 707, 727, 747, and 847 Single and Pairs of Doors Flush, Glazed, and Louvered single and pairs of 12/31/2017 Yes Yes Yes N/A 4 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 44X84 12/31/2017 No Yes No N/A 53 53: 053 W5-16 PAN-2F153: 84A, 94, 73, 75, 1500, 190, 4RST, 75, 1 Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" 05/21/2028 n (min. No Yes No +30 PSF/-30 hollow metal doors. 5 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 54X72 12/31/2017 No Yes No N/A 4RSF, 6RST, 6RSF, SF, 48, 42, 55, 488, 48B,AR542 55S, GD, S, wide) W E® WS Garage Door PSF 2 M, CM, and G Series Frames Three sided and four sided single and pairs of 12/31/2017 Yes Yes Yes N/A 7 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 54X72 12/31/2017 No Yes No N/A GDSF, GR5S, AR5S, ED5S, ED5SV frames. Tansom frames. 8 SERIES GA 195 ALUMINUM TRIPLE SH SERIES GA 195 ALUMINUM TRIPLE SH NI 12/31/2017 No Yes No N/A CONTINUOUS HEAD AND SILL 108X72 NON 85 OSS W6-09 PAN : 84A, 94, 42, 48, 42B, 48B, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/21/2028 No Yes No +38 PSF!-42 IMPACT 4RST, 6RST, GD5S, G , GR5S5S , AR5S, EDSS WINDCODE® W6 Garage Door PSF 9 SERIES GA 195 ALUMINUM TWIN SH SERIES GA 195 ALUMINUM TWIN SH NI 12/31/2017 No Yes No N/A CONTINUOUS HEAD AND SILL 88 1/8X72 102 102 W6-16 PAN-21`153: 73, 75, 84A, 94, 42, 48, 42B, 48B, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'2" 05/21/2028 No Yes No +37 PSFI-41 4RST, 6RST, GD5S, GR5S, AR5S, EDSS wide) WINDCODE® W6 Garage Door PSF Florida Department of Business & Professional Regulation Page 1 of 3 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Building Codes and Standards 1/92017 Product Approval Application Detail Florida Department of Business & Professional Regulation p g Page 1 of 1 O Product Approval Application Detail Building Codes and Standards 1/9r2017 FL#15278-R4 Product Approval Application Detail FL#75288-R2 Code Entity or Date Date Date Pending Date CIO Code Entity or Date Date Date Pending Date Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#15333-R2 Type Versio Manufacturer Contact Engineer & License Validated ev Validated Submitted FBC Approval Approved Status Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 09/01/2015 08/31/2015 09/05/2015 10/16/2015 Approved Affirmation 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 04/30/2015 04/30/2015 05/10/2015 Approved Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Code Entity or Date Date Date Pending Date Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 SubCategory: Fixed bsitiinger@miwd.com Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status SubCategory: Horizontal Slider bsitlinger@mnvd.com Compliance Method: Evaluation Report from a Revision 2014 MI Windows and Doors Brent Sitiinger Luis Roberto Lomas Steven M. Urich, PE 06/29/2015 06/19l2015 07/05/2015 08/19/2015 Approved . - Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Florida Registered Architect or a Licensed Florida Professional Engineer SubCategory: Mullions bsitlinger@miwd.com Professional Engineer FL#15278-R4 Products Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida FL#15286-R2 Products Quality Assurance Approved for Use Approved for Use Impact Design Professional Engineer Quality Assurance Approved for Use Approved for Use Impact Design Sag Sag # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Products Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 4 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 96X48 FIN 12/31/2017 No Yes No N/A 1 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12/31/2017 No Yes No N/A 5 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 72X72 12/31/2017 No Yes No N/A Quality Assurance Approved for Use Approved for Use Impact Design 72X54 FLANGE Sag # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12/31/2017 No Yes No N/A 7 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 96X48 12/3l/2017 No Yes No N/A 7 1445, 5347 AND 5547 VERTICAL MULLION 1445, 5347 AND 5547 VERTICAL MULLION 12/31/2017 No Yes Yes N/A 72X54 FLANGE 3 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/31/2017 No Yes No N/A 8 SERIES GA 275 THERMALLY BROKEN ALUMINUM PW SERIES GA 275 THERMALLY BROKEN ALUMINUM 12/31l2017 No Yes No N/A A-0 SLIDER PW NI 72X72 FIN Al 4 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER GA108X48198 SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/31/2017 No Yes No N/A 9 SERIES GA 505 ALUMINUM PW SERIES GA 505 ALUMINUM PW NI 72X72 FIN 12/31/2017 No Yes No N/A W SLIDER V ) 0 O LL (2) 0- U CIO O Florida Department of Business & Professional Regulation Page 1 of Florida Department of Business & Professional Regulation Page, of 1 Florida Department of Business & Professional Regulation Page 1 of 2 L- Building Codes and Standards 1/912017 Building Codes and Standards 1/9rz017 Building Codes and Standards 1/9/2017 Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail (n FL#13192-R4 FL#15272-R1 FL#5444-R10 M ■ ■ Code Entity or Date Date Date Pending Date Code Entity or Date Date Date Pending Date Code Entity or Date Date Date Pending Date Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Tvpe Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved talus Revision 2014 James Hardie BuildingProducts Inc. Pin Shen Zhu Ronald I. O awa John Southard P.E. 9 9 9 08/26/ 015 8 7/ 015 2 0 /1 2 09/07/2015 10/1 /201 6 5 Approved pp Revision 2014 Alside Nick Thom son Lyndon F. Schmidt, P.E. Ran J. King, P.E. p Y 9 02/23/2015 02/19/2015 03/01/2015 04/15/2015 Approved PP Revision 2014 CertainTeed Corporation -Roofing p 9 Mark Harper Robert Nieminen John W. Knezevich, PE 12/14/2016 12/08/2016 12/15/2016 Pending FBC Approval 9^ Category: Panel Walls (909) 349-2927 PE-24121 (352) 367-2526 Category: Panel Walls (330) 922-2389 PE-43409 (813) 767-6555 Category: Roofing (610) 651-5847 PE-59166 (954) 772-6224 {�L SubCategory: Siding pingsheng.zhu@jameshar SubCategory: Soffits nthompson@alside.com SubCategory: Asphalt Shingles mark d.harner@saint-gob Compliance Method: Evaluation Report from a die.com Compliance Method: Evaluation Report from a Compliance Method: Evaluation Report from a ain.com Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida L Professional Engineer g' Professional Engineer 9 Professional Engineer cz FL#13192-R4 Products FL#15272-Rt Products FL#5444-R10 Products W Quality Assurance Approved for Use Approved for Use Impact Design Sea # Product Model. Number Name Quality Assurance Product Description Contract Expiration Date Approved for Use Approved in HVHZ for Use Outside HVHZ Impact Resistant Design Pressure Quality Assurance Approved Approved for Use Impact Sea # 1 Product Model. Number or Name Cemplank Lap Siding Product Description Contract Expiration Date fiber -cement lap siding 01/01/2018 in HVHZ Yes Outside HVHZ Yes Resistant N/A Pressure N/A 1 or a. "2T" Soffit Vent or Solid Vinyl Soffit 12/31/2018 No Yes No N/A Sea # Product Model. Number or Name for Use Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Design Pressure G[ 11 (D 2 HardiePlank Lap Siding fiber -cement lap siding 01/01/2018 Yes Yes N/A N/A 2 b. ",Alliance T4"a Soffit Vent or Solid Vinyl Soffit 12/31/2018 No Yes No N/A 1 CertainTeed Asphalt Roofing Shingles 3-tab, 4-tab, strip (no -cut-outs), laminated and 07/03/2017 No Yes N/A N/A Z architectural asphalt roof shingles Z Q J IZ SHEET NO. PA 1.1 +-r U Cn Ca N -� > U L L Florida Department of Business & Professional Regulation Building Codes and Standards Page 1 of 1 1/9/2017 (D Q O (o ��,, Florida Department of Business & Professional Regulation Page 1 of 3 Florida Department of Business & Professional Regulation Page 1 of 1 �� ) ^^'' Building Codes and Standards 1/9/2017 Building Codes and Standards vs zo17 Product Approval Application Detail .� U Product Approval Application Detail Product Approval Application Detail FL#5219-R3 Q FL#12328-R7 Products Code Entity or Date Date Date Pending Date Q L_ Q Quality Assurance Approved for Use Approved for Use Impact Design FL#21675-RO Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Q Sea # Product Model Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Code Entity or Date Date Date Pendina Date Revision 2014 Thompson Architectural Metals Company, Inc. Scott Brown James L. Buckner Steven M. Urich, PE 05/01/2015 04/29/2015 05/10/2015 06/2312015 Approved 6 No. 15 UL Asphalt saturated organic fell 01107/2019 No Yes N/A N/A Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Category: Roofing (813) 248-3456 PE-31242 (717) 317-8454 �- QCIO > New 2014 HomeGuard Building Products, Inc. John Cheslak Intertek Testing Services NA, IntertekTesting Services 02/01/2017 01/25/2017 02/03/2017 Subcategory: Roofing Accessories that are an flvalidation@yahoo.com � C) O Integral Part of the Roofing System .(n — Approved Compliance Method: Evaluation Report from a C L },� Q Category: Roofing (904) 240-1382 Inc. NA, Inc. Florida Registered Architect or a Licensed Florida Q-- !� Search Criteria Subcategory: Underlayments john.cheslak@hgwrap.co (604) 520-3321 Professional Engineer � (0(n 4 Compliance Method: Evaluation Report from a m f-- Q Code Version: 2014 FL # 12328 Product Evaluation Entity FL#5219-R3 Products .!✓ Application Type: ALL Product Manufacturer: ALL Quality Assurance Approved for Use Approved for Use Impact Design Category: ALL Subcategory: ALL FL#21675-RO Products Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Application Status: ALL Compliance Method: ALL Quality Assurance Approved for Use Approved for Use Impact Design 1 1- "Flat Top Off Ridge Vent with Baffle for Tile" Minimum 26 Gauge Steel, Nominal 4', 6Ƈ, 12f3l/2019 No Yes No N/A Quality Assurance Entity Contract Expired: ALL Product Model, Number or Name: ALL Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 8', or 10', Wide Off Ridge Vent Attached to Product Description: ALL Approved for use in HVHZ: ALL 1 ToughSkin Synthetic Underlayments ToughSkin 15, ToughSkin 20, ToughSkin 25, 01/01/2018 No Yes N/A N/A Wood Deck ToughSkin 30, ToughSkin 50 2 Round Top Off Ridge Vent with Baffle for Gauge feel 1213112019 Minimum9; No Yes No N/A Approved for use outside HVHZ: ALL Impact Resistant: ALL Tile&quo 0260' Off Ridge Vent Attached to Design Pressure: ALL Date From: ALL Wood Deck Date To: ALL 3 3- "Standard Off Ridge Vent with Permanent Baffle Minimum 26 Gauge Steel, Nominal 4', 6', 1213l/2019 No Yes No N/A for Shingles" 8', or 10' Wide Off Ridge Vent Attached to Wood Deck Florida Department of Business & Professional Regulation Page 1 of 1 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/10/2017 Florida Department of Business & Professional Regulation Page 1 of 1 LUProduct Building Codes and Standards 1/9/2017 Building Codes and Standards 1/10/2017 Product Approval Application Detail Approval Application Detail Product Approval Application Detail FL#17202-R1 FL#2075-R7 Code Entity or > Date Date Date Pending Date FL#16588-RI Code Tvpe Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Type Versio Manufacturer Entity or Contact Engineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Revision 2014 Lomanco, Inc Andrew Carter James L. Buckner; P.E. Steven M. Urich, PE 05/01/2015 OS/01/2015 05/10/2015 06/22/2015 Approved Code Entity or - Date Date Date Pending Approval ate Approved Status Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Affirmation 2014 Florida Metal Products Inc. Clark Jones Miami -Dade BCCO - EVL Miami -Dade BCCO - VAL 0227/2015 0227/2015 03/09/2015 Approved Category: Roofing (501) 982-6511 PE-31242 (717) 317-8454 Affirmation 2014 O'Hagin Manufacturing, LLC Gregory Daniels Miami -Dade BCCO - CER Ted Berman, PE 06l17l2015 06/17/2015 06/25/2015 Approved Category: Roofing (904) 783-8400 (786) 315-2590 Subcategory: Roofing Accessories that are an acarter@lomanco.com Integral Part of the Roofing System Category: Roofing (707) 872-3620 (305) 868-4707 Subcategory: Roofing Accessories that are an clark@flamco.com Compliance Method: Evaluation Report from a Subcategory: Roofing Accessories that are an gdaniels@ohagin.com Integral Part of the Roofing System Florida Registered Architect or a Licensed Florida Integral Part of the Roofing System Compliance Method: Evaluation Report from a Professional Engineer Compliance Method: Certification Mark or Listing Product Evaluation Entity FL#2075-R7 Products FL#17202-RI Products FL#16588-R1 Products Quality Assurance Approved for Use Approved for Use Impact Design Quality Assurance Approved for Use Approved for Use Impact Design Quality Assurance Approved for Use Approved for Use Impact Design Sea # Product Model Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Se # ' Product Model. Number or Name Product Description Contract Expiration Date H Outside HVHZ Resistant Pressure 1 Deck -Air- DA-4 Low Profile, Polypropylene Plastic, Roof Vent 07/10/2019 No Yes No +97.5/-97.5 1 0'Hagin',s Cloaked Vent Tile Attic Ventilation Product for tile roofing applications 04/04/2018 Yes Yes N/A N/A 1 1 RV10 RV10 ALUMINUM RIDGE VENT 01/31/2018 Yes Yes N/A N/A Mechanically Attached to Plywood Deck. 2 OmniRidge®, PRO Vent PR04-N Molded Plastic, Roof Ridge Vent Mechanically 07/10/2019 No Yes No +N/A/-165 Attached to OSB or Plywood Deck. (D Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/9/2017 Product Approval Application Detail FL#15076-R3 Florida Department of Business &Professional Regulation Page 1 of 3 Building Codes and Standards 1/92017 Code Entity or Date Date Date Pending Date Type Versio Manufacture r Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status O Product Approval Application Detail Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 05106l2015 04/24/2015 05/11/2015 06/23/2015 Approved Florida Department of Business &Professional Regulation P 9 Pagel of 1 Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 Building Codes and Standards 1/9/2017 IN SubCategory: Storm Panels tim.robinson@gppent.com FL#7849-R9 Compliance Method: Evaluation Report from a Product Approval Application Detail Florida Registered Architect or a Licensed Florida Code Entity or Date Date Date Pending Date Professional Engineer Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#15088-R1 Revision 2014 Boral Roofing / Monierl-ifetile Thomas Jemmett ICC Evaluation Service, LLC Gary W. Walker 09/10/2015 08/25/2015 09/20/2015 Approved FL#15076-R3 Products Category: Roofing (602) 269-2288 (205) 854-0160 Quality Assurance Approved for Use Approved for Use Impact Design Code t Entity or Date Date Date Pending Date SubCategory: Roofing Tiles thomasjemmett@boral.co Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status _ Compliance Method: Evaluation Report from a P P m 1 20 Gage Galvanized Steel Storm Panels/HVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes N/A Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 04/27/2015 04/24/2015 O5l03{2015 06/23f2015 Approved PP - Product Evaluation Ent ltY or not b tracks to provide hurricane protection. Y p P Category: Shutters 9 rY 954 689-7545 PE-44167 954 772-6224 ( ) ( ) 2 24 Gage Galvanized Steel Storm Panels/NHVHZ Corrugated Galvanized Steel Storm Panels retained 12/31l2017 No Yes Yes N/A SubCategory: Fabric Storm Panel tim.robinson@gppent.com FL#7849-R9 Products or not by tracks to provide hurricane protection. Compliance Method: Evaluation Report from a Quality Assurance Approved for Use Approved for Use Impact Design Florida Registered Architect or a Licensed Florida Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15076-R4 Professional Engineer 13 Saxony 700 -Shake, Slate & Split Shake Flat Profile -Stockton 12/31/2018 No Yes N/A N/A Code Entity or Date Date Date Pending Date FL#15088-R1 Products 14 Saxony 900 - Country Slate, Shake &, Slate Flay Profile - Henderson 12/3112018 No Yes N/A N/A Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC AoProval Approved Status Quality Assurance Approved for Use Approved for Use Impact Design 15 Saxony 900 - Country Slate, Shake, Slate & Split Flat Profile - Lake Wales 12/3112018 No Yes N/A N/A Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 12/21/2016 12/21/2016 Validated Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Shake Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 1 GPP FABRIC SHUTTER -SERIES 2000 Coated Polyethylene Fabric Panels retained by tracks 12/3112017 No Yes Yes N/A 16 Saxony 900 - Hartford Slate, Split Old English Thatch, Flat Profile - Stockton 12/31/2018 No Yes N/A N/A SubCategory: Storm Panels tim.robinson@gppent.com or direct mounted to provide hurricane protection. J Shake, Slate, Country Slate Compliance Method: Evaluation Report from a } 24 Villa 900 Medium Profile - Lake Wales 12/3112018 No Yes N/A N/A Florida Registered Architect or a Licensed Florida 25 Villa 900 Medium Profile - Denver 12131/2018 No Yes N/A N/A Professional Engineer r11 26 Villa 900 Medium Profile - Stockton 12/31/2018 No Yes N/A N/A FL#15076-R4 Products Quality Assurance Approved for Use Approved for Use Impact Design Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure �J 1 20 Gage Galvanized Steel Storm Panels/HVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes N/A or not by tracks to provide hurricane protection. O /� �V 2 24 Gage Galvanized Steel Storm Panels/NHVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 or not by tracks to provide hurricane protection. No Yes Yes N/A O L_ U CZ Florida Department of Business & Professional Regulation Page 1 of 1 O Building Codes and Standards 11912017 }J L Florida Department of Business & Professional Regulation Page 1 of 2 Florida Department of Business & Professional Regulation Page 1 of 1 0— Product Approval Application Detail Building Codes and Standards 1/9/2017 Building Codes and Standards 1/9/2017 a) FL#12856-R5 Product Approval Application Detail Product Approval Application Detail (n Code Entity or Date Date Date Pending Date ICU Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#17869-RO FL#1999-R5 Revision 2014 Town and Country Industries, Tom Johnston Frank I. Bennardo ORLANDO L. BLANCO, 04/29/2015 04/28/2015 05/04/2015 06/22/2015 Approved W Category: Shutters SubCategory: Storm Panels (954) 493-8551 PE-0046549 P.E. tomj@tc-alum.com (305) 510-8531 Code Type Versio Manufacturer Entity or Contact Engineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Code Type Versio Manufacturer Entity or Contact Engineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Compliance Method: Evaluation Report from a New 2014 All American Shutters and Glass Mike Barbieri Frank L. Bennardo, P.E Jorge A. Pomerantz, P.E. 07/03/2015 07/03/2015 07/10/2015 08/18/2015 Approved Revision 2014 ITW Building Components Group Inc. ! Pasiode Stuart Lewis ICC Evaluation Service, LLC William M. Ranieri, PE 03/25/2015 03/20/2015 03/29/2015 Approved n Florida Registered Architect or a Licensed Florida Category: Shutters (561) 712-9882 PE-0046549 (954) 394-8521 Category: Structural Components (847) 918-6473 (407) 681-1917 I..L Professional Engineer SubCategory: Storm Panels mikeb@allamericanshutte SubCategory: Truss Plates sleWs@alpineitw.com FL#12856-R5 Products Compliance Method: Evaluation Report from a rs.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Product Evaluation Entity L� Quality Assurance Approved for Use Approved for Use Impact Design Professional Engineer FL#1999-R5 Products Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 0.050"a Aluminum Storm Panel 0.050"a Aluminum Storm Panel with Optional 12/31/2018 No Yes Yes N/A FL#17869-RO Products Quality Assurance Approved for Use Approved for Use Impact Design LU Clear Panels Quality Assurance Approved for Use Approved for Use Impact Design Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 "Safety Edge" Storm Panels "Safety Edge"a Storm Panels, 289a 12/31/2018 No Yes Yes +54/-54 Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 ITW BCG Higher Strength (H & S) Metal Connector Plate 12131/2020 Yes Yes N/A N/A (0.018"") Steel, 0.022"a Alum (Pert 1 22ga, 24ga Steel Panels 22ga, 24ga Steel Storm Panels 12/31/2017 No Yes Yes N/A 2 ITW BCG Hinge Plate Metal Connector Plate 12/31/2020 Yes Yes N/A NIA Q and Non -Pert) Clear Polycarb (Full and Half) 3 ITW BCG Trulox Metal Connector Plate 12/31/2020 Yes Yes N/A NIA Z 3 24ga Steel Storm Panel 24ga (0.0232") Steel Storm Panel with Optional 12/31/2018 No Yes Yes +100/-100 4 ITW BCG Wave Metal Connector Plate 12/31/2020 Yes Yes N/A N/A Clear Panels Z 4 Aluminum Hinged Storm Panel .050"a Aluminum Non -Porous Hinged Storm 12/31/2018 Yes Yes Yes N/A Panel ._J IZ SHEET N0. PA 1. 2 Tr ____ _. _T T _. — I __ ___T_ I - - r I N c— C/) CB N }. >O C U L L N Q O FL#1645-R4 Code Type Versio Revision 2014 Manufacturer Boise Engineered Wood Products Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entityor Contact Engineer & License Validated By Robert Taylor ICC Evaluation Service, LLC APA - The Engineered (541) 826.0200 Wood Association roberttaylor@bc.com (253) 620-7467 Date Date Validated Submitted 05/27/2015 05/06/2015 Date Pending FBC Approval Date Approved 06/02/2015 Page 1 of 1 1/92017 Status Approved Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/9/2017 Product Approval Application Detail FL#2197-R5 Code Entityor Date Date Date Pending Date Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 MiTek Industries, Inc. David Wert ICC Evaluation Service, LLC ICC Evaluation Service, 06/30/2015 06/11/2015 07/05/2015 Approved Category: Structural Components (314) 851-7480 LLC. SubCategory: Truss Plates dwert@mii.com (205) 599-9800 Method: Evaluation Report from a Product Evaluation Entity Florida Department of Business &Professional Regulation Page 1 or 1 Building Codes and Standards 1/9/2017 Product Approval Application Detail FL#1644-R4 Code Entityr Date Date Date Pending Date Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval roved Status Revision 2014 Boise Engineered Wood Products Robert Taylor ICC Evaluation Service, LLC APA - The Engineered 05/27/2015 05/06l2015 06/02/2015 Approved Category: Structural Components (541) 826-0200 Wood Association SubCategory: Engineered Lumber roberttaylor@bc.com (253) 620-7467 Compliance Method: Evaluation Report from a Product Evaluation Entity •� V - (/) U O O 0 Q Q O r 4-- � Q � (D L 42) CoCompliance C U At �>V Q Q FL#2197-R5 Products FL#1644-R4 Products Product Evaluation Entity Sea # Product Model. Number or Name Quality Assurance Approved for Use Approved Product Description Contract Expiration Date in HVHZ for Use Outside HVHZ Impact Resistant Design Pressure Sea # Product Model, Number or Name Quality Assurance Approved for Use Approved Product Description Contract Expiration Date in HVHZ for Use Outside HVHZ Impact Resistant Design Pressure FL#1645-R4 Products Quality Assurance Approved for Use Approved for Use Impact Design 1 M18SHS 18 ga, super high strength truss connector plate 12/31/2017 Yes Yes N/A N/A 1 Versa -Lam Laminated Veneer Lumber 01/01/2035 No Yes N/A N/A Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 MII 16 16 ga. truss connector plate 12/31/2017 Yes Yes N/A N/A 1 AJS Joists Wood "l"a Joists 01/01/2035 No Yes N/A N/A 3 MT18HS 18 ga. high strength truss connector plate 12/31/2017 Yes Yes N/A N/A 4 MT20 20 ga. truss connector plate 12/3112017 Yes Yes N/A N/A 5 MT20HS 20 ga. high strength truss connector plate 12/3112017 Yes Yes N/A N/A Search Criteria Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 FL#6527-R6 Florida Department of Business &Professional Regulation Building Codes and Standards Page 1 of 1 1/92017 Code Tvpe Versio Revision 2014 Manufacturer Weyerhaeuser Entityor Contact Engineer & License Validated By Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. Date Date Validated Submitted 07/06/2015 05/12/2015 Date Pending FBC Approval Date Approved 07/30/2015 Status Approved FL#158-R7 Product Approval Application Detail LU FL#1630-R8 Code Type Versio Revision 2014 Manufacturer Weyerhaeuser Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity Product Approval Application Detail Entityor Contact Engineer &License Validated By Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. (253) 924-4084 (608) 839-1344 jim.anderson2@weyerhae user.com Date Date Validated Submitted 07/06/2015 05/12/2015 Date Pending FBC Approval Date Approved 07/30/2015 Status Approved Category: Structural Components SubCategory: ry: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#6527-R6 Products Sea # Product Model, Number or Name 1 iLevel Rim Board 2 Microllam LVL 3 Parallam PSL 4 TimberStrand LSL (253) 924-4084 (608) 839-1344 jim.anderson2@wyerhae user.com Quality Assurance Approved for Use Approved for Use Product Descriotion Contract Expiration Date in HVHZ Outside HVHZ Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes board Rim Board Laminated Veneer Lumber 03/31/2017 No Yes Parallel Strand Lumber 03/31/2017 No Yes Laminated Strand Lumber 03/31/2017 No Yes Impact act � Resistant N/A N/A N/A N/A Desi n � Pressure N/A N/A N/A N/A Code Tvpe Versio Manufacturer Revision 2014 CAST-CRETE USA, Inc. Category: Structural Components SubCategory: Products Introduced as a Result of New Tech nolo 9y Compliance Method: Certification Mark or Listing P g FL#158-R7 Products Sea # Product Model. Number or Name 1 High Strength Concrete Lintels oDate Date —Entity— Contact Engineer & License Validated By Validated Submitted Craig Parrino Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 03/16/2015 02/24/2015 (813) 621-4641 (786) 315-2590 cparrino@castcrete.com Quality Assurance Approved for Use Approved Product Description Contract Expiration Date in HVHZ 4, 6, 8, and 12 inch wide lintels 05121/2016 Yes Date Pendina FBC Approval for Use Outside HVHZ Yes Date Approved 03/18/2015 Impact Resistant N/A Status Approved Design Pressure N/A mi FL#1630-RB Products Quality Assurance Approved for Use Approved for Use Impact Design FL#6527-R7 FL#158-R8 Sea # 1 2 3 4 5 6 Product Model. Number or Name TA 110 TJI 210 TJ1230 TJI36360 TJI 560 TJI/560D Product Description Contract Expiration Date in HVHZ Prefabricated Wood I -joist 03/31/2017 No Prefabricated Wood I -joist 03131/2017 No Prefabricated Wood I -joist 03/31/2017 No Prefabricated Wood I -joist 03/31/2017 No Prefabricated Wood I -joist 03/31/2017 No Prefabricated Wood I -joist 03/31/2017 No Outside HVHZ Yes Yes Yes Yes Yes Yes Resistant NIA N/A N/A N/A NIA N/A Pressure N/A NIA NIA N/A N/A N/A Code Type Versio Revision 2014 Manufacturer Weyerhaeuser Category: Structural Components Subcategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity Entity or Contact Engineer & License Validated By Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. (253) 924-4084 (608) 839-1344 jim.anderson2@weyerhae user.com Date Date Validated Submitted 10/31/2016 10/25/2016 Date Pending FBC Approval Date Approved 11/05/2016 Status Approved Code Type Versio Revision 2014 Manufacturer CAST-CRETE USA, Inc. Category:p Structural Components SubCategory: Products Introduced as a Result of New Technology Compliance Method: Certification Mark or Listing Entity or Contact Engineer & License Validated By Craig Parrino Miami -Dade BCCO - CER Miami -Dade BCCO - VAL (813) 621-4641 (786) 315-2590 cparrino@castcrete.com Date Date Validated Submitted 05/06/2016 04/29/2016 Date Pending FBC Approval Date Approved 05/06/2016 Status Approved FL#6527-R7 Products FL#158-R8 Products Sea # Product Model. Number or Name Quality Assurance Approved for Use Approved Product Description Contract Expiration Date in HVHZ for Use Outside HVHZ Impact Resistant Design Pressure Sea # Product Model. Number or Name Quality Assurance Approved for Use Approved Product Description Contract Expiration Date in HVHZ for Use Outside HVHZ Impact Resistant Design Pressure 1 Microllam LVL Laminated Veneer Lumber 03/31/2017 No Yes N/A N/A 1 High Strength Concrete Lintels 4, 6, 8, and 12 inch wide lintels 05/21/2017 Yes Yes NIA N/A 2 Parallam PSL Parallel Strand Lumber 03/31/2017 No Yes N/A N/A 3 TimberStrand LSL Laminated Strand Lumber 03/31/2017 No Yes N/A N/A 4 TJ Rim Board Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes N/A N/A board Rim Board — 5 Weyerhaeuser Rim Board Oriented Strand Board Rim Board 03/31/2017 No Yes N/A N/A (D Florida Department of Business & Professional Regulation Page 1 of 1 O Florida Department of Business &Professional Regulation Building Codes and Standards Page 1 of 1 1/92017 Building Codes and Standards Product Approval Application Detail 1/92017 Florida De nt of Business & Professional Regulation Department g p Building Codes and Standards Page 1 of 1 1/92017 Product Approval Application Detail Product Approval Application Detail FL#5450-RSCz FL#1774-R4 Code Entity or Date Date Date Pending Date FL#11383-R4 Code Type Versio Revision 2014 Manufacturer Commercial Concrete s,lnc. Category: Structural Components SubCategory: Products Introduced as a Result of New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Entity or Contact Engineer &License Validated By Robert Gillis THUY H. HUYNH Florida Engineering (813) 659-3707 PE-60122 Solutions precastgator@yahoo.com (352) 588-5311 Date Date Validated Submitted 07/03/2015 06/24/2015 Date Pending FBC Approval OS/20/2015 Date Approved 08/26/2015 Status Approved Type Versio Revision 2014 FL#5450-R5 Products Manufacturer Powers Steel Inc, Category: Structural Components SubCategory: Products Introduced as a Result of New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Contact Engineer & License Validated By william powers Steven W. Schaub SAMUEL A. (602) 437-1160 PE-60509 GREENBERG, RE, bill@powerssteel.com (813) 645-0166 Validated Submitted 03/26/2015 03/23/2015 FBC Approval 03/30/2015 Approved 06/23/2015 Status Approved Code Tvice Versio Revision 2014 Manufacturer Powers Steel Inc. Category: Structural Components SubCategory: Products Introduced as a Result of New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Entityor Contact Engineer &License Validated By william powers Steven Schaub SAMUEL A. (602) 437-1160 PE-60509 GREENBERG, P.E, bill@powerssteel.00m (813) 645-0166 Date Date Validated Submitted 03/26/2015 03/23/2015 Date Pending FBC Approval 03/30/2015 Date Approved 06/22/2015 Status Approved Cz FL#1774-R4 Products S # Product Model. Number or Name PL 1 Quality Precast or Commercial Concrete Products Quality Assurance Approved for Use Approved Product Description Contract Expiration Date in HVHZ Precast and Prestressed Concrete Lintels 05/25/2024 No for Use Outside HVHZ Yes Im pact Resistant N/A Design Pressure N/A Sea # 1 Product Model. Number or Name PSbox8LT, PSbox8LT(5-5/8) Quality Assurance Approved for Use Approved Product Description Contract Expiration Date in HVHZ Powers Steel lintels are field assembled lintels 01/27/2017 No consisting a preformed steel lintels combined with concrete masonry units, grout, and steel reinforcing bars. for Use Outside HVHZ Yes Impact Resistant N/A Design Pressure N/A FL#11383-R4 Products Seq ## Product Model. Number or Name 1 PowerBOX8 Lintels Quality Assurance Approved for Use Approved Product Description Contract Expiration Date in HVHZ Powers Steel Lintels are field assembled consisting 01/01/2017 No of preformed steel lintels combined with brick or concrete masonry units, grout, and steel reinforcing for Use Outside HVHZ Yes Impact Resistant N/A Design Pressure N/A ^1 W bars. W ^' V O _O U O �J L U) V cn Q U m w� a ZJ O z Q J SHEET NO. PA 10 T � I