HomeMy WebLinkAbout37764 Dusty Saddle Ln370�Roosevelt CMU GaraLye RiLyht - Elevation J SHEETINDEX NUMBER: 5PEE7 N.4"E: NUI-15ER: 6;-�EE7 NAME: CS- COVER 6PEET 05 3 SQUARE FOOTAGE CALCULATIONS A-32 MISC DETAILS F-110 FOUNDATION - SLAB PLAN A-33 MISC DETAILS A-3.4 MI5C DETAILS 4 - 1.0 FIRST FLOOR PLAN A-2 . 0 SECOND FLOOR PLAN A-3.20 FRONT/REAR ELEVATIONS J/ROOF PLAN A-321 SIDE ELEVATION$ J 4-4.0 BUILDING SECTIONS E-1.0 ELECTRICAL PLANS - FIRST 4 SECOND FLOOR P-0.1 PLUMBING RISER DIAGRAM ENERGY REQUIREMENT 5GWEE)ULE EXTERIOR WALLS FR�WE) R.13 EXTERIOR WALLS (BLOrK) 4.1 FOIL ATTIC rEILIW. R-30 GENERAL NOTE5 THE STANDARD GENERAL 5PIEVIFICATION5 FOR AMERICAN HOMES 4 PENT 4 AMH DEVELOPMENT SHALL GOVERN EXCEPT AS MODIFIED 4 SUPPLEMENTED BY THESE WINDOW INSTALLATION, PLANS� 1. WINDOWS SHALL BE INSTALLED AND FLA--44ED IN ACCORDANCE WITH THE MANUFACTURER'. WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION 3. DUCTS IN THE GARAGE AND DUCTS PENETRATINGS THE WALLS OR CEILINGS THESE PLANS HAVE BEEN DESIGNED TO MEET TWE REQUIREMENTS OF- INSTRUCTIONS 5HALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. SEPARATIW. THE DWELLING FROM THE GARAGE SWALL BE CONSTRUCTED OF A MIN, 2023 FLORIDA BUILDING CODE, RESIDENTIAL, 5TW EDITION -26 GAUGE (0.45 -) SWEET STEEL OR OTWER APPROVED MATERIAL AND SHALL OCCUPANCY; SINGLE FAMILY RE&IDENTAL FLOOD ZCLNE FEQLRQ�T HAVE NO OPENINGS INTO TWE GARAGE. 1. PLAN MEET$ OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION. I ON, H 4. -OLND TONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE AAEOVE 1. I�E BE SEPARATED FROM THE RE51DENCE AND ITS ATTIC AREA BATH AREAS. IN STALLED THE BASE FLOOD ELEVATION AND SHALL ALSO CONFORM TO THE BY NOT LESS THAN 1/2 INCH (121 �.) GYPSUM BOARD APPLIED TO THE GARAGE 1. INSTALL 2x4 BLOCKING AT TOILET PAPER AND TOWEL BAR LOCATIONS, SEE MANUrACTURER'S INSTALLATION INSTRUCTIONS. SIDE GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL DETAILS. HABITABLE ROOMS ABOVE BY N07 LE55 THAN 5/8 INCH (15S -) TYPE "X" GYPSUM 5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE BOARD OR EQUIVALENT. UjWIERE= TWE SEPARATION 16 A FLOOR -CEILING ASSEMBLY, KITCHENS, PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING TWE STRUCTURE SUPPORTING THE SEPARATION 5WALL AL50 BE PROTECTED BY N07 1. INSTALL 2X& BLOCKING AT SS" AFF, ON CENTER FOR UPPER CABINET COMPONENT WILL Or -CUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN LESS THAN 112 INCH (121 ..) GYPSUM 50ARD OR EQUIVALENT. INSTALLATION. PIPING SYSTEM- THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS Or SECTIONS M14113. EXTERIOR FINISHES, AREAS: THICKNESS OF TEXTURED FIN15H OVER FRAME APPLICATION SHALL BE PER THE T "14R BER-CEMENT, OR GLA55 MAT GYPSUM BOARD (NO GREEN BOARD EXHAUST FANS AND VENTING; CURRENT APPROVED BUILDING CODE AND A67M CS26. IN57ALLATION OF EXTERIOR ALLOWED) IN COMPLIANCE WITH ASTM C1258, C1325, OR C1118 AND INSTALLED WITH -5 1. OUTDOOR DISCIHARSE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST LATWING AND FRAMING APPLICATION REQUIREMENTS TO BE PER TWE CURRENT . 1-1/14" DA6GERZ PHILIPS WAFER WEAD CEMENT 150ARD SELF DRILL 5CREW5 W/ SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS. AIR SHALL NOT BE EXHAUSTED APPROVED BUILDING CODE AND A5TM C O(�3, COATING SWALL BE USED 46 BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, INTO AN ATTIC, 5OFFIT, RIDGE VENT OR CRAWL SPACE. AND WALL PANELS IN SHOWER AREAS. EGRESS, 2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE 1. EACH BEDROOM MUST WAVE ONE WINDOW TWAT COMPLIES WITH EGRESS CODES. IF TREATMENT: Rr=C:lRr-ULATED WITWIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SWALL BE THERE IS NO ACCESS TO EXTERIOR TWROUGW A DOOR. THE WINDOW MUST WAVE A T! PROTECTION SWALL BE PROVIDED BY REGISTERED TERMITICIDEES, rXWAU5TED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM 5ATWROOMS` AND MAXIMUM OPENING WEIGHT OF: 44" ABOVE FIN15H FLOOR LINE OF TWAT PARTICULAR INCLUDING SOIL APPLIED PESTICIDES, BAITIW. SYSTEMS, AND PESTICIDES APPLIED TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE. OR OTWER ROOM. 70 WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR AREAS INSIDE THE BUILDING. USE AS A PREVENTATIVE TREATMENT TO NEW CON15TRVCTION. UPON COMPLETION OF 2. IN DWELLING UNITS W14ERE THE OPENING OF AN OPERABLE WINDOW 16 LOCATED THE APPLICATION Or THE TERMITE PROTECTIVE TREATMI A CERTIFICATE OF 3. DUCT LENGTH. THE MAXIMUM ALLOWABLE EXHAUST DUCT LENGTH SHALL BE MORE TWAIN 12 INC14ES ABOVE THE FINISHED GRADE OR SURFACE BELOW, 7WE COMPLIANCE SWALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED DETERMINED BY ONE OF THE METWO08 SPECIFIED IN SECTIONS 111502.45.1 TWROU6514 LOWEST PART OF TWE CLEAR OPENING Or THE WINDOW SHALL BE A MINIMUM Or 24 PEST CONTROL COMPANY TWAT CONTAINS THE FOLLOWING STATEMENT: "THE M1502,45.3. TL4r MAXIMUM LENGTH OF: THE EXHAUST DU -T SHALL BE 35 FEET FROM r INCWES ABOVE THE FIN15HED FLOOR. OPERABLE SECTIONS OF WINDOU-6 SHALL NOT EUILDING HAS RECEIVED A COMPLE'TE TREATMENT FOR THE PREVENTION OF THE CONNECTION TO 7WE 7RANSITION DUCT FROM THE DRYER TO THE OUTLET PERMIT OPENINGS TWAT ALLOW PASSAGE OF A 4'' 5PWIERE LL44ERE SUCH OPENINGS SUBTERRANEAN TERMITE$. TREATMENT 16 IN ACCORDANCE UJITH Ri AND LAWS TERMINAL. THE MAXIMUM LENGTH Or THE DUCT SWALL BE REDUCED 2.5 FEET (162 ARE LOCATED WITHIN 24 INCHES Or THE FINISHED FLOOR PER 7WE CURRENT ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER FOR EACH 45 DEGREE (01S RAD) BEND AND 5 FEET (IS24 -) FOR EACH SO APPROVED BUILDING CODE. SERVICES." DECREE (Ib RAD) BEND. THE MAXIMUM LENGTH OF THE 1I DUCT DOES NOT INCLUDE TWE TRAN51TION DUCT. EXCEPTION - WHERE A CLOTHES DRYER 500STER FLASHING, LIE HVAC. CLL---t� ��CUILATIONS FAN 15 INSTALLED AND LISTED AND LABELED FOR THE APPLICATION, THE MAXIMUM SWING, SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK 1. FLA AND 1. EtE FOR HEATING AND COOLING CAPACITIES SHALL BE LENGT W OF THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE WALL INTERSECTIONS, AT GUTTERS, A7 ALL CHANGES IN ROOF SLOPE OR DIRECTION. FURNISHED BY THE MECHANICAL ENGINEER AS AN ATTACHMENT TO THIS PLAN SET PERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FAN MANUFACTURER'S AND AROUND ROOF OPENINGS. AT THE 71ME Or APPLICATION FOR PERMIT INSTALLATION INSTRUCTIONS. LUPERE A CLOTHES DRYER B005TER PAN 15 INSTALLED AND NOT READILY ACCE551BLE FROM THE ROOM IN LUWICW THE DRYER 15 LOCATED, 2 APPROVED CORRO51ON-RESISTANT FLASHING SWALL BE APPLIED SHINGLE 2. MECWANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, A PERMANENT IDENTIFYING LABEL SWALL BE PLACED ADJACENT TO WHERE TLE FASHION IN SUCH A MANNER AS TO PREVENT ENTRY OF: WATER INTO THE WALL REPAIR, AND REPLACEMENT UJITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER EXHAUST DUCT ENTER$ THE WALL, TWE LABEL SHALL BEAR THE WORDS "THIS DRYER CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED 70 THE APPLIANCE EXHAUST SYSTEM IS EOUIPPED WITH 4 REMOTELY LOCATED 500STIER FAN." COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR 15EIWG INSPECTED, SERVICED, REPAIRED, OR REPLACED. A LEVEL 110RKING SPACE WALL FINISH. APPROVED CORROSION - RES157AN'T FLASHING SHALL BE INSTALLED AT AT LEAST 30 INCHES (162 -) DEEP AND 30 INCHES (162 -) WIDE SHALL BE 4. PROVIDE BACK DRAFT DAMPERS AT INTAKE AND EXHAUST LOCATIONS AS ALL REQUIRED LOCATIONS PER THE CURRENT APPROVED BUILDING CODE. PROVIDED IN FRONT Or THE CONTROL SIDE TO SERVICE AN APPLIANCE. REQUIRED BY THE CURRENT APPROVED BUILDING CODE. ISSUED: 4/30/2024 VERSION: 5.0 SQUARE FOOTAGE AH4R ASSET MANAGEMENT SO. Fr. HEATED AREA Sq. Ft. MAIN LEVEL 1102 SECOND LEVEL 1215 TOTAL AH4R SCL FT. [SWWnilill) I 23TT METHODOLOGY: ANSI Z766-2W3 The total area Calculated from the outside -to -outside of framing, including optional finished basement options as sh- This area excludes staimell at highest level above grade, garage, covered patio/porches. ALL WORK SHAUL CC'MPLY V1111-H PREVAIL'Nci CODES FLORIDA SM --DiNG C-00E, NATiONA! - ELECTRIC CODE, AND THE CITY OF ZFP�iyr�Hjl ORDINANCE$ C1T-'y'0FZr---PH'VRH'JAJS/ PLANJ `---,-,A NER ") Q Z- VV sc-- I C- 51 ,5-7-76q IM1 AT14 DEVELOPPIENT DO NOT SCALE SE DRASING6. VEIZ� SULDING. ORIENTATION UIT CONITIZACTOR AND 51TE PLANS SEFM CONSTFZJCTICR TASE DRA1465 00 NOT CCNTAIN SFECFIC INTO�TION FOR A0 STfZrTLRAL EUETENTS (TO BE PROVOM By EW.NEER OF IMCM) ANT' DECIREPANCY (P41ENSION16, ORIEWATON, ETC.1 BETUEEN TNESE DPAURW AND ASSOCIATED DRAAWA SKIIV SITE DRASINGS SH&L BE IEFORTED To CONTRACTOR AT OWE AV NO O0NSTRXTICN SWALL PFZCE D UNTIL CORFEMD. TNE CONTM4CTOR ASSILITES TIE FESPONSE51LITYTOMIEF L MQJ RETIENTS OF LOCAL BUILDW, CRICIALS I TO COMPLY WTH STATE > (U LU r ,I- C) z 12 0--q un cc 0 Ca '6 C) C> F- 7 6�hl- L -j 11111111111111M. I FAE VERSION: 5.0� COVER SHEET 9w# SQUARE FOOTAGE CHART ELEVATIONT ------------------- SQUAREFOOTAGE CONSTRUCTION AREA CALCULKnON HEATED / CONSTRUCTION AREA Sq. Ft. MAIN LEVEL 1102 5EGOND LEVEL 12b4 TOTAL HFATEDWNSTRUCTION AFMA (SlabCwM) MW METHODMOGY: ANSI Z765-2W3 The total area Calculated from the outside -to —side of irwing, including optional finished basement options as sh— This area excludes stainvell at highest level above grade, garage, covered patio/potches. BUILDING ENVELOPE AREA (ALL AREAS UNDER ROOF) Sq. Ft. GARAOE 444 XVERED PATIO 112 FRONT PORCH 5b TOTAL BUILDING ENVELOPE (SIBM>W) 2978 METHODOLOGY Building Envelope Ama: The total area calculated, including Heated/Construction area as calculated, and also including garage, covered patio/porches. MAXIMUM DEPTH 601-01, IMAXIMUM HIPTH 1.*MAXIMUM E�)ILDINS HEJ&HT A.F.F. 2`�-5" *021 AMW DO NOT SCALE WESEDRAIMA VERIFY BULDW. CREMATION UT CMMTOR AND SM PLANS BEFORE C06TRCT TWESE DRASINGS DO NOT CONTAIN SPECFIC INFORWION FOR STRUCTURAL ELEMENTS (TO BE PRXIDED By ENGINEER OF RECORD1 AN' DISCREPANCY (DtIENSIONS, OKWAVON, ET J BETWEEN IWESE DRA10,61 A41 ASSOCIATED DRA"6 'W" 6 TE DRA11W,6 $HALL BE REPORTED TO CONTRACTOR AT OWE AND NO CONSINXTION SMALL FRXEED LXTIL COMECTED. TWE CONTRACTOR AWAIMES T4 WSFMI51LITY TO MEET ALL MEM REWS OF LOCAL BULDM OFICLALS f TO Ca'FLY UM STATE Bul Dw�� 4-j r. W C, > v w =�Mlj C) 0-4 ca CD U Cn (D< (n V) C> � C) cel r- -1 VERSION: 5.0 SQUARE FOOTAGE CALCUATIONS gw� ICS-31. ov, A/C PAD CON SLAB M 6 FIC5:El;llr:rlp uj/ 25 SH PATIO 5 HE 4' CONCRETE SLAB MIN. OVER b WVAC CHASE IS MIL VAPOR BARRIER SLAB ALL EASED ON BE OVER CLEAN COMPACTES44 LL LOCATION - /J. W1 FZERMESI� ELECTRICAL ��.JT AL Colou FOR ISLAND _0 CONCRETE 5L,45 F T, 4" CONCRETE SLAB MIR OVER 6 ML - IL, I POR BARRIER. SLAB 644ALL BE OVER C AN COMPACTED FILL W1 FIBERME51-1 a, SECOND FLOM SANITARY ---------- - - ------------ - -------- ---------- I D Lu --------- --------- 0 i,. C", -LAB MIN. v W1 F15ERME5H I - W V ----------- --- FORCH SLAB-' 0 w (L ----------------------- ---------- RETE CON SLAB \FIBEMIESH OVER 6 MIL V BARRIER SLAB L BE e�r 14"-CONCRETE16LADEMN, OVER CLEM COMPACTED VAPOR BARRIElk SLAB SHALL BE OVER FILL Ul FIBEWES14 CLErMCOMPACTED FILL W1 Y-41 1[:�� 1'-4" 1� - 1&'-3" OF�ENING aO'-O" OVERALL SLAB PLAN - ELEVAMN"J" WAM IN IIW= WME, IN: lw FOUNDATION PLAN NOTE5 ALL WOW SHALL BE IN STRICT COMIANCE WIT14 IBUILONG. GODE, RESIDENTIAL, AID COLNTY BUILDIW. DEPARTMEN7. STRIP TOPSOL, TREES, WrS, ROOTS, ETC. FROM ALL AREAS IIHERE CONSIRLICTION LOLL OCCUR UND. FILL SHALL BE FIRILY CalPACTEO, CLEAR $AND/CLAY MATERIAL: FREE OF ROOTS, OR3ANIC MATTER OR OTHER NTERIOR BEARING, LOCATIONS 6�10IJLQ BE COORDINATED UTI4 TF456 MAKFACTURER 4 STRICT.11RAL ENSINEER. PROVIDE IL TREATMENT AND VAPOR BARRIERS AT ALL SLA55 (INTERIOR). &021 " DEVELOWIENT Do NO SCALE THESE DRAWN6.5 VERIFY WILDWI ORIENTATION UTO CONTRACTOR AND SITE PL" aulow CONSTFIXT THESE DRAW" DO NOT CONI SPECFIC INFORUTION FOR ANY SIRIXT.RAL EU3'Dff& (TO ]NE PRO�cw BY EWINEER OF RECORD). ANY DISCREPANCY IDITIENSIONS, ORIENTATION, ETCJ BETUM THESE DRA1061 AND ASSOCIATED DRAWNG$ —/. 6 DRAIN635 WALL BE REPORTED TO CONTRACTOR AT CE AND No C" CONSTFIXTION WALL PROC ED WIL COFFECTED THE CONTRACTOR ASKITIES, THE RESPONSIBUTY TO MET ALL REMNEMN18 OF LOCAL 5J LDING CRICIALS 4 TO COTIIkY OTH STATE BUILDW, CODES, 4-j V -01 � f o > V > Lu C) z �-q cc CD C,* C�o C) 04 C:� E-4 IN F --I L —1 AE ��. — I VERSION: 5.0] FOUNDATION - SLAB PLAN am# F-1.0-1 k4NDRAIL 1-1/2" MIN GRASPABLE LANDRAIL 1 1/4., MIN TO t IlMll �/2 IDIa" MAX IN AMETER-0 IL SECTI,ONI �VIDE kANDRAIL IN COMPLIANCE WITW THE cjjFaww Ap"Ro`�C` BUILDIN6. CODE. 57,41R DIAGRAM_ FLOOR PLAN NOTE5 PROVIDE 1/2'(111NIMIM)GYPSUM BOARD SEPARATION AT WALI-5 AND5/8' TYPE X rEILwG5 IN TWE GARAGE ADJACENT TO T�E MAIN WOUSE AND ATTIC AREAS. WASHIWG MACHNE 15 ALWAYS LOCATED LEFT OF TWE DRYER LIII NOTED OTHERUSE ALL EXTERIOR WALL$ ARE DRALLIN AT S' CM JKLESS NOTED OT�IERUSE ALL INTERIOR AND C"N WALLS ARE DRAWN AT 3 1/2' KEES NOTED 04ERUISE 14EADER FOR FIRST FLOOR 16 AT W-0' .1 V-4" CLG I SECOND FLOOR 15 AT l'-V" V 8'CLG 14MORAIL �E*Nl WALL BE 36'MEASUMED VERTICALLY FROM T�E NOSING OF TW TREAD 0) DENOTES EGFEE56 WINDOW FIRST FLOOR PLAN - ELEVATION "J" 1112 WAM iff-11IF eml " DEVELOPMDU DO NOT 5CALE TWSE DKAffW,& 4X� BUiLDW, ORI NIATION WTW CCNTRACTCR AND STE PLANS BUORE CONSTRXTION. TESE DRAMW DO NOT CONTAIN SPECIFIC HFOI�MATION FCR STRICTLIR& ELEIENTS (TO BE PRO�CED 5y BGMR OF RECORD). W DISCREPANCY (I)PEN51M, ORENTATICN, ETC.) BETWEEN 74ESE ORMIN35 AID TIE ASSOCIATED DRA0r.5 Vella SITE DRAILINGS S4ALL BE REPORTED 7 CONTRACTOR 7 ONCE A14D NO CONI 5HALL PAOCE LNTIL CORFECTED. T�E CONTRACTOR AMLMES THE RESPONSIBIL rry TO MET ,MQJ REVENTS OF LOCAL BUt-DNG OFFICIALS 4 TO CMWITN STATE 5UILONG 5 4-1 r. 'I (U In o > Flo w Ul C) z CD 0 C—) Ej 2 C) C Lof en F -I L I VA1411t. I FAE j VERSION: 5.0] FIRST FLOOR PLAN aw"w swo A-1.0 PANEARAIL 1-1/2" MIN GRASPAISLE �ANDFtAll- , 1 114" MIN To 1-1�" MAX DIAMETEWO RN it ClION AN PROV DE NANCRAIL N COMPtIMCE WITW TILE CURRENT APPROVED MILDING CODE, 5TAIR DIAGRAM FLOOR PLAN NOTE5 PROVIDE 1/2' (MINII GYPSLIM 50AFD SEPARATION AT WALLS AND 5W TYPE X CELW-15 IN T�E GARAGE ADJACENT TO TWE MAN HOJSE AND ATTIC AREAS. WASHING MAC4lE 16 ALWAYS LOCATED LEFT OF TWE DRYER tINLIESS NOTED C41ERWISE. ALL EXTERIOR WALLIS ARE DRAWN AT B" CMJ LNI NOTED OT14ERIMSE ALL HTEROR MD COnlCN WALLS ARE DRAUN AT 3 112' LJNLE55 NOTED 076EIWBE. IkEADER FOR FIRST FLOOR 15 AT S'-O" ./ S'-4'CLG I SECOND FLOOR 15 AT 1'.0* V S'CLG 14ANDRAIL 4EG4T 5WALL BE US" MEASURED VERTICALLY FROM TLE NOSING OF TWE TREAD. (1) DENOTES EGRESS WINDOW DOOR TO FAU — CLOW FAU BOLVIVOR 2C.4-C DOOR CLOSErWALL PER KM FRAAWG B C RAISED PLATFORM YEW SECOND FLOOR PLAN - ELEVATION "J" SGUL10114= Sm IN-1'4r 42021 " DEVELORW DO NOT SCALE UESE DR40I VEM IIUlLDNG OW KTATION UT4 CONTR4CIOR AND SITE PLA45 INEFORE cotaTparTION. TASE DRAJI DO NOT CONTAIN SFECFIC WORIATIC14 FOR STICICTURAL ELBVHS (TO BE PROVIDED BY EWNEER OF RECOFD), ANY DISCREPANCY 'DrIENSIM. OMITATION. ETCJ BETWEEN TWM DRAILWA AND THE AS$XIATEV DUWW.5 Wl. SrrE DRAWINGS SIAL BE FEPORTED TO CONTRACTOR T ONCE *0 NO C49NSTRJCTION SkkL PROCE D LINTIL COMICTED Ue CONTRACTOR A.SUME5 T IIESPONINBILITY TO MET K�JRETENTS OF LOCA. 5U LDM C��ICIALS A TO COMPLY UN STATE BUILDW, CODES E'd > A LLI 12- ca a) Q 0 ca co C) co I rz t— rTl F L VERSION: 5.0 SECOND FLOOR PLAN owt A - �2�.O ] Typ. ROOF PLAN RX 1111N.E.1mr.1'r 19m rAL. Iff."r CZ ZONE I ATTIC VENTILATION: (3W5QFT ATTIC SPACE /I SOFT VENTILATION) -CALCULATIONS REFLECT 50% RIDGE AND 50% SOFFIT VW6 1316 SO FT UNDER ROOF ATTIC / 3W SQ FT / I 5Q FT - 43t 80 FT VENTILATION OFF -RIDGE VENT N L38 50 IN EACH (4' VENT) 6OFFIT VENT - 5 so IN EACH 435 SQ FT x 50% 2.15 50 Fl flrl4,2.IS 50 FT LOW HIGH VENTING 2.1s SO FT 144 60 IN -315M 50 IN REQUIRED T OFF -RIDGE VENT x 138 5Q IN 414 W IN LOW YENTW, 2.1%50 FT W4 W IN .315.84 SO IN REQUIRED �15B4 / S 35 SOFFIT VENTS (CCNTINUOUS VENTED SOFFIT) ZONE 2 ATTIC VENTILATIOK- (300 SO FT ATTIC SPACE / I SO FT VENTILATION) 210 W FT UNDER ROOF ATTIC / 30050 FT / I SQ FT - .10 50 FT VENTILATION SOFFIT VENT 5 60 IN EAC14 LOU) VENTING .10 SQ FT x 144 SQ IN -100W 50 IN MQUIRED IWW / 9 " SOFFIT VENTS (CONRIMICUS VENTED SOFFIT) ZOI,E 3 ATTIC VENTILATION: (3W 50 FT ATTIC SPACE I 150 FT VENTILATION) 5b 50 FT UNDER ROOF ATTIC / 300 80 FT /150 FT - IS 50 FT VENTILATION SOFFIT VENT 5 SO IN EACH LOW VENTING .19 50 FT 144 50 IN :26M 50 IN REQUIRED 26M / 5 3 SOFF IT VENTS (CONTINUOUS VIEWTIED SOFFIT) ZONE 4 ATTIC VENTILATION: (300 W FT ATTIC SPACE � I SO FT VENTILATION) 142 SOFT LINDER ROOF ATTIC / 3W 50 PT / I SQ FT � .4150 FT VENTILATION SOFFIT VENT 5 50 IN EACH LOU) VENTING Al SQ FT x 44 60 IN -68.14, SQ IN REQUIRED b8th / b - 8 SOFFIT VENTS (CONTINUOUS VENTED SOFFIT) 6112 PITCH Af Ix3 BOARD 4 BATTEN � 16" OIC) PER C011`114TY $PECS (TYP) 6 " TRIM LINE OF ____FLA_'AWG MP) .. . . . . . . . . . . Fil l!j] 4�2 PITCH W SWW ILE ROOF (TYP) in -0- TRIM 4' CORNER TRIM 6" TRIM ID'.bV' BOARD AND BATTEN SHUTTERS PER COMMUNITY SPECS (TYP) 4" TRIM AND SILL LINE OF FLASHING fTYP) ("I RAISED STUCCO TRIM COACH LIG441 PER Comm SPECS CEMENTITIOUS STUr _CO PER COMM ISPE -5. 4" RAISED STUCCO TRIM HORIZONTAL LAP SIDIW . PER COMM 5PECS 4" CLIWER TRIM (IYP.) CEMEN717ICUS STUCCO PER COMM. SPECS 0021 Amm DEVELOPMENT DO NOT SCALE THESE DR4111455 VERIFY EI ORI WATION WTH CCNTRACTOR AND SITE PLANS BEFORE CONSTRICT ON. THESE DRAW436 DO NOT CONTAIN SPECIFIC 1WORU71ON FOR ANY STRLICTLIRA EUI (TO BE PROVIDED BY EW.NEER OF RECORD2 � DOCREPANCY (DIMENSIONS. ORIENTATION, ETr BETIM TWESE DRAIR406 AND TIE A%OCJATED DRAWWA ­V� SITE DRAUNGS SkAL BE REPORTED TO CONTRACTOR T ONCE 4ND NO CONSTRUC 04 &LALL PROCEED UNTIL CORRECTED. THE ClOWtRACTOR AS&kfS Tit RESPONSIBILITY TO MEET 'MORI NT60FLOMBUILDW, OFICZ'SEA TO COMPLY LATH $TATE BUILDING CODES 4-) CL > > t LU �jj a F-4 c_ C) cm (D z 0­4 C.O') cc CD cn I 0 - u C_.) -n Q< C:) x Z� 7 L I iInximor. I ME ] VERSION: 5.0] FRONT/REAR ELIEVATI - & ROOF PLAN IA-3.201 TOP OFFALCIA —2�d-FJR CEIIJ15% stfL RILM FIN FLR ELEV C'M PITCH ARCH SHW.LE ROOF (TYP) TOP OF FA5CA — UFUR-C - 2r EILV, W106ULRE- HORIZONTAL LApTYP- SIDING. PER COMM 4" CORNER TRIM LILINEOF FLA5HIWj (TYI-) 5ECCND FLR 6t FU�CEILWG WINDOLULKE CJAlEEf- L FIN FLR ELEV RlGKr SIDE ELEVATION 'J' SCALE iffill'o, = WAM 1/811'r 12 S F:� HORIZONTAL L Ap TYF', BIDIN3 PER COMM SPECS- 4" CORNER 12 4 E--�-- 6M PITCH ARCH WING.-E IWOF (TYP) " PITC14 12 ARC14 514W.LE ROOF (TYP) � bM PITCH `� 6 FRIEZE LINE OF FI-Ar;,HIW3 (TYP) --m' LEFT SIDE ELEVATION "Ju CEMEN7171OU5 5TUCCO PER COMM. SPECS. BTUCCO PER Comm. sncs, 4=1 AlN DEVELOPPIENT Do NOT SC E THESE DRALWA, VEIRFY IBUILDM ORI NUTION W17W CCNTRACIOR AID IIE PLANS EEPORE COSTIRrTION. THESE DRAIJINGS DO NOT CONTAIN SPECIFIC NFOWLATION FOR ANY SlKrT,PA ELEIIENTS fTO BE PROVIDED By 94GNEER OF RECORD) ART DECRIPAWY ,DMOONS, ORIENTATION, ET BETUM TWESE ORAWWA AND THE AWOCIATED DRAWN6.5 �la 5TE DRALWA IWAL BE IMPORTED TO CONTRACTOR CHCE AND NO CONSTRZ CN SHALL PROCEED LfITIL COFMCTED. THE WNTRACrOR ASWIES THE FIESPONUBILITY TOPEET FEEW TSEN16 OF LOCAL BUILDW. OFFICIALS 4 TO COTPLY UATA STATE 51JILDW, CmE& Lp -n 0 Lij > w Am cm ICE ca U "'S ce) (D (a � J4 F- -1 L wort. I FIN _j VERSION: 5.0� SIDE ELEVATIONS INEET# A- QMI " M-YELOMENIT 00 NO SCALE THESE DRAWWA. B�ILDING 5ECTION NOTE5 VeRFY BUILM OR NTATION WIN CONTRACTOR AND SITE PLANS BEFOR CONSTRJClICK THESE PLEASE NOTE: THESE DETAILS An STRICTLY ARCHITECTURAL, REFER TO STRUCTURAL DRAWWA DO NOT OMAN SHEETS FOR TOM NFORMATION SFECPC WOR11ATION F ANY STRUCTURAL EUR'WS (TO 5E SECTIONS SIMILAR TO OTHER ELEVATION5 AND WHEN USI% 2xb EXTERIOR WALLS PWVVED BY BCWNEER OF RECORDI ANY DISCREPANCY CIDIMENSIONS, ORIENTA7104, ETC) BETUM THE T AD T " D"WN' ASSOCIATED DRAWWA �J� SITE DRAWW'S SHALL BE REPORTED TO CONTRA, 12 _TCR AT ONCE AID W CON67RCTION SWALL PROCEED XNL CORRECTED. THE CONTRACTOR ASOLM5 THE REWONN LLTTY TO M99T ALL PSE-11"FACTURED TRUSSES REQU .1..IS OF LOCAL BUILD'. OFFICIALS 4 TO COVILT WTH STATE 5UILDM CODES. INSULATION PER FE3C AND ENERGY FO OFOF FALCIA 51.15MIT71ED WITH PERMIT APPLICATIO V------------- jWd Ii7LR`CE —ILIW—. 'WRow LINE 0, 0 Lu ib LOFT 3 > ro Q) '6 SECL34D FLR Ll I IS 14 BEDROOM 2 A PALL BATH I HALL NBEIIIIIIENZE MW w mvmm IFIN FLR ELE�v \v COMPACTED, TEWITE TREATED SOIL IVAPOR BAWER FOUNDATION (SEE BUILDING SEC'nON"AW STRUCTURAL PLA ICAlE;lr-I'fpI07) EMATIGHTSHIMN-AULEUNATIONSSNIUR SCAM W-I'qp" "It C) z V cc 6 le�- CD PRE -MANUFACTURED TFZJ55ES 0 INSULATION PER FIBC AND ENERGY FORM 6UBM17TED WITH PERMIT APPLICATION TOFLOF WCIL Cj) V) I LA LOFT N6U 6U13 P p RY 5UITE _IMA RIMARY 5UITE 5 12 12 SECOND FLR 4 U �l 11 1 4 C� I V., FLR CE 16 w CJALEEP 13 L GOVEFZED ol w 1) FRONT GREAT ROOM w FOYER PORCH L w Fm FIN FLR ELEV I 1 11 !7 \ I I T COMPACTED, TERMITE TREATED $OIL .1VAPOR ------- VERSION: 5.01 1. 16 TREADS IV'- BA" - 13-%" BARRIER FIELD VERIFY FOUNDATION (SEE BUILDING SECTIONS 2 / BUILDING SECTION OBB" STRUCTURAL PL OMM W-117 =7) ELEACWTINDIIIIII-ALLIELIEVAT&A SIAM 4. ol ELECTRICAL LEGEND Q-5 GA-5 LINE V RECESSED CAN LIGHT ON COLD WATER 0 FLUSH MOUNT LED I=m ELECTRICAL PANEL 2 WALL MOUNTED LIGHT ELECTRICAL METER WALL SCONCE E=P DISCONNECT SWITCH FLUORESCENT L614T 0 BULB $ SWITCH EZZZZZ3 FLUORESCENT LIGHT wl 2 BULBS, 3-WAY SW17CW VAPOR PROTECTED LIGHT 4-WAY SWITCH EXHAUST FAN DIMMER SWITCH 14) EXHAU5T FAN LIGHT BUTTON (9) ]EXHAUST FAN w/ HEAT A LIGHT DUPLEX OUTLET 0 SMOKE DETECTOR QUAMEX OUTLET CARBON MONOXIDE DETECTOR SWITC44ED DUPLEX THERMOSTAT OUTL T '�00P 0 FLOOR OUTLET DIRECT WIRE G11 d GFI OUTLET T PHONE JACK WPGFI db WATER PROOF GFI mi MEDIA JACK OUTLET T CLG 0 CIEILNG MOUNTED CABLE TV OUTLET OUTLET 220� 4) 220v OUTLET DOOR CHIMES cEILNG. MOUNTED 5ECURiTY PANEL LIGHT HANGING CEILING FLOOD LIGHT MOUNTED L 6WY In I n I C-4::::) CEILING FAN I I C _D CEILING FAN wt LIGHT u ELECTRICAL GENERAL NOTE5 SWITCHES TO BE 45" AFY RECEPTS. TO BE 12" APF. - 42" IF OVER A COUNTER ALL WIRWG TO BE IN ACCORDANCE WITH NEED ARC FAULT CIRCUIT NTERRUI PROTECTION SWALL BE PROVIDED AS REQUIRED IN NEC 210.12(A) AND SHALL BE INSTALLED IN A READILY ACCE561BLE LOCATION. ALL SMOKE DETECTORS SHALL BE WARDORED INTO AN ELECTRICAL POWER SOLRCE AND SWAL L BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS. GROUND FAULT CIRCUIT INTERRUPTER SWALL BE PROVIDED AS REQUIRED IN NEC 210,9(A) AND INSTALLED IN A READILY ACCESSIBLE LOCATION IT 5 THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO INSURE TWAT ALL ELliCTRICAL WOW, 15 IN FULL COMPLIANCE WITH NFPA 10A - NEC AID ALL APPLICABLE LOCAL STANDARDS, CODE5, AND OFDINANCES. PROVIDE INTERSYSTEM BONDING TREMINATIrN AT SERVICE LOCATION PER NEC 250.S4 LUMINAIRES IN CLOTHES CLOSETS SHALL BE WTALLED PER THE PROVISIONS OF NEC 414211 (5) RECESSED LISWI TO BE AIR TIGHT AND IC RATED IM95, OF T14E LAMP'S IN PERMANENTLY INSTALLED FIXTURES SHALL BE Wr.W-EFFICIENCY LAMPS REFER TO ENERGY CALCULATIONS FOR ADDITIONAL INIFORMA710N. PROVIDE T14E REQUIRED CLEARANCES AROUND PANELS AND DISCONNECTS I COMPLIANCE WITH NEC 11026 ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC 40612 THE BRANCH CIRCUIT SUFFLY1W. THE RECEPTACLE(fl) IN A GARAGE $14ALL NOT SUPPLY CUTLETS OUTSIDE OF THE GARAGE AND NOT LESS T14AN ONE RECEPTACLE CUTLET SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE. AFCl PROTECTION - 210.12 (5) DUELLING UNITS. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DUELLING UNITS, FAMILY RClCMS DINW. ROOM, LIVING ROOMS, PARLOR5, L15RARES, DENS BEDROOMS $UNROOMI RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR RD" OR AREAS $HALL BE PROTECTED BY A LISTED AFCI, COMBINATION TYPE INSTALLED TO PROVIDE PROTECTION OF BRANCH CIRCUIT. 410 AL SfR CABLE GROUNDING ELECTRODE 5WALL COMPLY WITW 5EC 250.52 ELECTRICAL R15ER DIAGRAM N.7.5. X't�'F.00 . LIGHTRA. F[ 142'qp 0 CLGGFI t---------------------- ------- ----- -------------- OFT DEDICATED 50 AIIPS (14-50 NEMA 2401) IF REQUIRED By CODE — - — - — - LIP FIRST FLOOR ELECTRICAL PLAN - ELEVATION OX SONE-Imllw= soke W-11111' ON]"DIEVELOPMENT 00 NOT SCALE THESE DRAWMGS, VII BUILDW. CRI TATION OTH CONTRACTOR AND FLANS BEFORE CONSTRUCT THEM DRA~ DO NOT COWAN SPECIFIC WORIAlION FOR MY STRUCTURAL ELEMENTS (TO BE PROVIDE BY ENGNEER OF RECORD) ANY DLCXPANCY 'DIMENSIONS, OREWATIM II BETWEI THESE 01 AND THE ASSOCIATED DRAI wi� SITE I)R4VW,6 SWAL BE REPOIRTED TO COTRACTOR T ONCE AND NO CONSTFIXTION SHALL PROCEE .NTL CORSECTED UE CONMZACTOR ASSUMES TIE FE5PCNI TO MEET ALL WOW 5 OF LOCAL II MICIALS A TO COMPLY WIN STATE BUILDING CODES (u 4� 0" 0 w > w E < TINEWEIIIIIIENZ 1 4111111110 REI I C) (D z 123 �_q V) ca (D u-) 0 c'n >. a) 0 Elf 04 7 L _j WAIII I FAE VERSION: 5.01 ELECTRICAL PLANS FIRST FLOOR IE-1.0_1 ELECTRICAL LEGEND -+ GA5 GAS LINE RECESSED CAN LIGHT -+ COLD WATER FLUSH MOUNT LEI) ELECTRICAL PANEL 2 WALL MOUNTED LIGHT ELECTRICAL METER WALL --CNCE DISCONNECT SWITCH FLUORESCENT LIGHT mA Bi $ SWITCH i FLUORESCENT LIGHT ./ 2 5UL58 3-WAY 50TCW VAPOR PROTECTED LIGHT 4-WAY BLUITC14 EXHAUST FAN DIMMER SWITCH EXHAUST FAN w/ LIGHT BUTTON EXHAUST FAN HEAT I LIGHT DUPLEX OUTLET SMOKE DETECTOR QUADPLEX OUTLET CARBONI MONOXIDE DETECTOR SWITCHED DUPLEX THERMOSTAT OUTLET FLOOR OUTLET I? DIRECT WIRE GFI I'm 6 GFI OUTLET T PHONE JACK WPGFI WATER PROOF GFI 6 OUTLET MEDIA JACK CLC CEILING MOUNTED 4D OUTLET CABLE TV OUTLET 22� 220v OUTLET DOOR CWTMES CEILING MOUNTED SECURITY PANEL LIGHT HANGING CEILING FLOOD I MOUNTED LIGHT n n 1:4--:D CEILING FAN C:- CEILING FAN LIGHT u ELECTRICAL GENERAL NOTES SWITCHES TO BE 45' AFF RECEPT5. TO BE IV' AFF. - 42' IF OVER A COUNTER ALL WIRING, 70 BE N ACCORDANCE WITH NEC ARC FAULT CIRCUIT INTERRUPTER PROTECTION SHALL BE PROVIDED AS REQUIRED IN NEC 211 AND SHALL BE rlBTALLED IN A READILY ACCES511BLE LOCATION. T INTO ALL SMOKE DETEIC ORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP PROVIDE AND INSTALL LOCALLY CMIFIED SMOKE ]DETECTORS. GROUND FAULT CIRCUIT INTERRUPTER SHALL BE PROVIDED AS REQUIRED 114 NEC 211 AND INSTALLED IN A READILY ACCESSIBLE LOCATION. li IT 5 714E RESPONSIBILITY OF THE LICENSED ELECTRICIAN 70 1 TWAT ALL ELECTRICAL WOW 15 IN FULL COMPLIANCE WIT14 Ni 10A - NEC AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND MINANCES. PROVIDE INTERSYSTEM BONDING TREIINATIC14 AT SERVICE LOCATION PER I M54 LUMINIARES IN CLOTHES CLOSETS SWALL BE INSTALLED PER THE PROVISIONS OF NEC 411 4 (5) RECESSED LIGHTINC, TO BE AIR TIGHT AID IC RATED M OF THE LAMPS N PERMANENTLY INSTALLED FIXTURES SHALL BE HGH-EFFICtENCY I REFER TO ENERGY CALCULATIONS FOR ADDITIONAL INFORMATIOR PROVIDE THE REQUIRED CLEARANCES AROLIND PANELS AND DISCONNECTS IN COMPLIANCE WITH NEC III ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC 40&.12. THE BRANCH CIRCUIT SUPPLYING THE REOEFTACI IN A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE GARAGE AND NOT LE86 THAN ONE RECEPTACLE OLITLET SHALL BE INSTALLED FOR EACH MOTOR VE141CLE SPACE. AFCI PROTECTION - 211 (5) DWELLING UNITS. ALL 120 VOLT, SINGLE PHASE, 5 AND 20 AMP BRANCH CIRCUITS SUPPLY IW. OUTLETS INSTALLED IN DUELLING UNITS, FAMILY I DINING ROOMI LI VING ROOMI PARI LIBRARIES, DENS, BEDROOI SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED AFCI, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF BRANCH CIRCUIT. ------------------- x V Typ qp AX DWONNECT -10i /\Y\ V\� I LT(LATTICj db — — — — — — — — — — — — — SECOND FLOOR ELECTRICAL PLAN PART. SECOND FLOOR ELECTRICAL PLAN ORD21 Ai DEVELOFMENT Oo NOT SCALE DRALi VEXFY BULDING ORIENTATION WIN CCNTRACTOr AND SITE PLANS BEFORE CONSTISICT THESE DRAWNGS DO NOT C40NTAN SPECFIC WORMATION FOR ANY Sllfti ELS-eas (TO BE PROVIDED by ENSNEER O� RECORD) ANY DISCREPANCY fIDITENSIONS, ORIENTATION, ETC.) BETWEEN THESE DRAWi AID THE ASSOCATED DRi ftd� SITE DRAW" 5WAL BE REPORTED TO CONTRACTOR AT ONCE 40 NO CONSTAIr ION ISWALL PROCEED LWIL CORRECTED. THE CONTRACTOR AS&UMES THE li Try TO MET ALL Mai OF LOCAL BU LOW. 1101FICIA-1 I TO Y STATE EW'I -4-) f o > w 7 NUMMM I 40M m] C) z 0-4 V) co (!) Cii C 5 in' Ql co C) cr VERSION: 5.0 ELECTRICAL PLAN SE COND FLOOR ai E-2.01 HOUSEWRAP BARRIER 0, JOINTS) OVER WENIOR SHEATHING PER SPEC­SH TO OVERLAP RUIRIERIZE1 FLASHING RUBBERIZED 7HRU-WAU. HASHING, VITEND UP ir VERTICALLY (4- MIN VERTICAL PROJECTION ABOVE SUBROOR), TRIA TO OUTSIDE FACE OF BRICK THRU-WALL FLASHING_ NOT TO SCALE HOUSEWRAP BARRIER (TAPE ALL JOINTS) OVER MERIOR SHEATHING PER SPEC -SHEATHING TO OVERLAP RU BLDG FELT BETWEEN HASHING JSEWRAP BARRIER AND 'K VENEER-TYPIC AL UP RUBBERIZE13 THRU-WALL HASHING, EXFEND UP 11' VERTICALLY 1,C MIN VERTICAL PROJECTION ABOVE SUBROORI, E F TRIM TO OUISID ACE EP HOLES AT COURSE OF BRICK )VE HASHING - 24"O.C. RIZONTALLY SOLID GROUT BEHIND HOUSEWRAP BARRIER - REFR TO DETAIL FOR CUTTING COORDINATE 15# BUILDING FELT BARRIER AT WINDOW OPEN APPLICATION WHERE BRICK VENEER IS SPECIFIED -FOLD HOUSEWRAP DOWN OVER HEAD HASHING AND APPLY CORNER PATCH EXTENDING I" MIN. BEYOND WRIER CUT -INSTALL HEAD HASHING OVERLAPPING WINDOW FLANGES A MIN. OF 7 - INSTALL UNDER HOUSEWRAP -APPLY JAMS HASHING OVER SIDE WINDOW RANGES - MIN. I'ABOVE HEAD AND T OVERLAP AT SILL INSTALL WINDOW OVER SEALED AND HASHED PREMANUFACIURED SILL PAN BEFORE TAPING - FILL ENTIRE INTER OR PERIMETER GAP W IC NON -EXPANDING FOAM OR SEALANT TAPE SEAM OF OVERLAPPING PLASTIC SILL BOOT PREMANUFACtURED PLASTIC SILL MOT WINDOW OPENING FLASHING NOT TO SCALE — — — — GABLE END WERE OCCURS REFER IELEVATIONS AND DETAILS TYPICAL ROOF COVERING PER SPEC ':��12 SEE ROOF --"'PL*AN PLAN TYPICAL ROOF TRUSSES PER SPEC TYPICAL ROOF INSIAATION MR M ROOF ROOF DRIP EDGE PER CODE & COMNIL SPEC ?SrRUCPJRAL TOP Of mu. Typ. INT. CLG. REFER TO ELEVATIONS MATERIAL - PER SPEC Z FASCIA PER CODE & COMM. SPEC, REFER 701 TYPICAL SOFFIT FINISH PER SPEC FOR TRUSS TO WALL � ALL TE BEAM - REFER SrRUCTUR4 CONNECTION TRIM PER ELEVATION PER SM V CMU BLOCK REFER SIRUCrURAL TYPICAL STUCCO FINISH ON BLOOK PER SPEC TYPICAL INTERIOR WALL FINISH AND INSULATION OVER BLOCK PER SPEC J_� WAINSCOT PER ELEV. PER SPEC VERIFY FOUNDATION PROFILE VARIES BY TYPICAL BASE LOCATION / CONDITIONS PER SPIEC REFER STRUCTURAL VERIFY DUAL MR TEINNATION WALL IE FINISH AT FOUNDATION PER ELEVATION A MATERL'L REFER TO PLOT PLAN FOR SLOPE CONFIGURATION TYPICAL 1 -STORY WALL SECTION NOT TO SCALE 15# BLDG FELT BETWEEN HOUSEWPAP BARRIER AND &RICK VENEER -TYPICAL CONTINUOUS MORTAR NET WEEP HOLES AT COURSE ABOVE HASHING - 24'O.C.. HORZONTALLY FOUNDATION BRCK LEDGE THRUMALL FLASHING @ BRICK LEDGE NOT TO SCALE — — — — — GABLE END WHERE OCCURS 12 REFER EUNATIONS AND DETAILS TYPICALROOFOOVERINGPERSPEC TYPICAL ROOF TRUSSIES PER SPEC 4 TYPICAL ROOF NSLILATION PER SPEC REFER TO STRUCTURAL FOR ME TO WALL CONNECTION TYPICAL INFIERIOR WALL RNISH AND BASE PER SM DRIP EDGE PER CODE & COMAk SPIEC ­ATIONS FASCIA PER CODE & COMM. SM. TYPICAL SM FINISH PER SPEC TYPCAL WALL FINISH ON FRAME W/ SHEATHING, PER ELEVATION, PER SPEC TYPr­Al 2C FRAME WALL AND SHEATHING - REFER STRUCTURAL jIaff. _ To ENATIONS - WATERPROOF WALL FINISH TRANSITION VARIES BY SEVATION. RES DETAILS AND SPECS I TOW -ATIONS T YP. INT. CLG. MATERIAL - PER SPEC DRIP EDGE CRACK CONTROL AND WEEPS REFER DETAILS AND SPECS REFER TO SFRUICrURAL7H FOR TRUSS TO WALL CONNECTION TIE IIIAM REFER STRUCFURAL It CMU BLOCK REFIR STRUCTURAL TYPICAL STUCCO FINISH ON BLOCK PER SPIEC TYPICAL INSERIOR WALL FINISH AND 94ULATION OVER BLOCK PER SPIEC WANCOTT PER ELEV. PER SPEC VERIFY FOUNDATION PROFILE ' VARIES BY TYPICAL BASE LOCATION / CONDITIONS PER SM REFER STRUCTURAL VERIFY DETAL FOR TENNATION WALL FINISH AT FOUNDATION PER MATION AND MATERIAL "IRT, REFER TO PLOT PLAN FOR SLOPE CONFIGURATION TYPICAL 2-STORY WALL SECTION NOT TO SCALE Ea /� BRICK ROWLOCK - tREFER TO ELEV. BRICK SOLDIER (OR) 3 BRICK COURSES -REFER SO ELEV. THRIJ-WALL MEMBRANE HASHING WAINSCOT DETAIL NOT TO SCALE HOUSE WRAP OVER WALL SHEATH14G - PROVIDE ENOUGH OVERLAP TO COVER METAL HASHING AND THROUGH -WALL FLASHING TAPE OVERLAPP14GSEAM SUING PER SPEC ITBeNTMEFALRAHNG- EXTEND $'VERTICALLY EXTERIOR SEALANT I CAST STONE SILL OR BRICK ROWUDCK- TO ELEVATION BRICK TIE WEEP HOLE THRU-WALL MEMBRANE HASHING TO FACE Of BRICK W1 MIN. 24' VERTICAL LEG. LAP UNDER BUILDING WRAP. 7ff STUCCO OVER FRAME (SHEATHING. 2 LAYER W.R.B. LATH AND STUCCO) - PER SPEC PEEL & STICK BRIDGE FLASHING, SHINGLE LAPPED OVER STUCCO ACCESSORY VINYL PLASTER DRIP SCRM - PER SPEC INSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS CAP SHINGLE - DO NOT STAPLE OR NAIL ROOF CEMENT SHINGLE ROOFING ON ROOFING UNDERLAYMENT- PER SPEC PEEL & STICK BRIDGE HASHING. OVERLAP ON TO ROOFING UNDERLAYMENT 6W CORROSION RESISTANT BASE R"ING - PER SPEC PREENGINEEIRED WOOD TRUSSES SEE STRUCTURAL AND TRUSS DRAWINGS FOR SPACING AND CONNECTION DETAILS NOTE' ALL ROOFING MATERIAL (PER 13"ATION) SKALL BE INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTION. VERIFY ROOF SHEATHING WITH STRUCTURAL DRAWINGS ROOF TO WALL AT RAKE r stucco OVER FRAME (SHEATHING, 2 LAYER RJL. LATH AND STUCCO) - PER SPEC EL & STICK BRIDGE RASHING� SHENI LAPPED fiRsnjccOACCESSM NYL PLASTER DRIP SCREED - PER SPEC STALL PER MANUFACTUREIM INSTALLATION STRUCTIONS HASHING kP SHINGLE - DO Nor STAPLE OR NAA )OF CEMENT KC CORROSION RESISTANT BASE ASKING (M) RE -ENGINEERED WOOD TRUSSES SEE TRUCIURAL AND TRUSS DRAWINGS FOR PACING AND CONNECTION DIETARS YPICAL EXTERIOR WALL ASSEMBLY - SEE UCrURAL DRAWINGS NOTE ALL ROOFING MATERIAL (PER ELEVATION) MALL BE INSTALLED PER MANUFACrUREn MALLA71ON INSTRUCTION. VERIFY ROOF SHEATHING WITH STRUCTURAL DRAWINGS (ROOF TO HEAD OF WALL - SHINGLE_ � �nl?lll' CMI AM DEVELOPMENT Do NOT SCALE TWER DRA11W.S. YER� BULDWS ORIENIATION UMTW CONTRACTOR AND SITE PLANS BEPOW CIMTRXT OR T�IESE DRAWA DO NOT CONTAIN SKCFIC KFOFaIA71CN FOR ANY STRXI.RAL ELE�IENTS (TO BE FR7VM BY ES614EER OF RECORD) ANY D6CREPANCY (DRIENSIONS. OMENTATION, ETC.) BETUEEN T�ESE DRAWN6.5 AND TA ASSOCIATED DPAANSS SWIM Sn DRAMA $WALL 5E REPORTED TO CZNTRACTOR AT ONCE AND NO CON5lRr ION WALL PROCEED LNTIL CORRECTED. TIE CrQNTR4CTOR ASSLMS TIE RE5PON5811. rrY TO M7 ALL REQU 5 OF LOCAL BUILDW, OPFIVALS 4 TO CO�KY UM STATE BUILDW, CODES Q) 0 LL, > V W Q) U �i RERM C) cc U C-;l :1 ae CO 0 r in N IMMI Wt. I BE j VERSION: 5.01 m MA-3. HANDRAILS SHALL NOT BE LEBSTHAN 34' OR MORE THAN 31' IN HWHT ADM THE STAIR NOW& K4MMMMBEOMflNOAFIRROffOFSTAF& HANDRAILS SHALLBEI lrtCLEAROFALLADJACENTRMMRTERMANDBO SHALLRETURNTOWALLORTERMINIITEI ORAPPRDMEQUIMAUENT,N POSTSORSAFE K91DPAU WAL BE AND BE SWIN NTH NO ON EDOESIDORNERS STAR AND RIULING SUPPLIER INSTALLER SHALL. SATISFY ALL SUMUMNS FOR T' 'E OBVIRIMENT APPROVAL REQUIREMENT11 FOR THE PROOUCTII THEY PROM OR INSTALL 'm GUARMUS SHALL NOT BE LESS 2DO In -- A. THAN W IN HEIGHT ANY DIRILMON ANY ASUE M _ A THE HANDRAIL COMMUCI)ON SHALL BE ABLE M RESIST A ON A ANY _ LOAD OF20O UBBAPPLIED INANY DIREC7ION ATANYPOINT AL.ONGTKTOPRM. ON= OPEN RMUIISKALL MVE WISIMIMTE PAU ORAN v MAY ORINNIENTALPI SLENTHINTArDIAMETER SPHERE NO CANNOTPASSTHROUGH. THROUGH rSPHEIIEMAY THEQUIVIORALCONITRUCRONSHALLEI)EABLE IKITPASS TO RENT ACONCENTRATED LOAD OF 20D LBIS IN THFO" ANYDIRECTION THIS DIMIRAM LLUSINATES THE THE Tisma" OPENINGS AT F EIQ I IS 1113 e 4 T 8 0 F 7 H E STAIRTREAD1,11SER.&WITOM �F ODEANDISONIYANAID MUM C SHAUL BE SUCH THAT A S' DIAMETER FORBUILDINGDESIGNAND FOR SPHERECANNOTPASSTHROUGH. CONsYRrnON HANDRAIL/GUARDRAIL CODE DATA SCALE! 1112"m V-0" FINISHEDSURFACE EQ.TREADS SEE PLAN 3WPLYWOODTFF" Z w Ci w wo 2X121IMMEDSTRINGER(II SITINM MIN AT EACH ffrm w" h4plIA.SION Xp) GAP ON PLYWOOD FIBERS (ryp.) SECURE NOTCHED STRONGER TO BILL PLATE L (I)M02STRINGERSTYP. WITH FRAMM ANCHORS. SEDURE PLATE TO SIA WITH SLOT PINS. ALL WOOD 14 DFW CONTACT WITH CONCREFE TO BE PRESSURE TREATED OR PRKNIDE NPERVIOUS MEMBIRANE SEPARATION AS ALLOWED BY CODE. FLOOR/STRINGER DETAIL SCALE� 11/2"= I'-C' & FRAMING - Dr. W. — 1XICSIORTBOARD, 262 STRINGER &4 SPACER W TYPX W. BO. AT ALL WAUSANDOMMOF ENOLMLSABLESPACE UNDERSTAIR SKIRTMALL DETAIL SCALE: 11/2"- F-C" FINISHED SURFACE —EQ.TREADS MATCH HMHT OF SEE PLAN BASEBOARD WPLYWOODTREADS . 41 1 114'MIN. Z'MAX. 11/4'MIN.-2"MAX. 11/2�CLR 3/4' HMIDNOOOTOPRAL Typ WALLBRACIIETAT a 94r MC. MAX We W PLYWOOD FISERS 4FXP�ANSION BAUJSTERSSPACEDAT4 SW=MA)L Typ. 2X12 NOTCHED STRIVER Ap be= (Typ.) EXPANSION CAP TYP. P)MC129TRINGERSTYP. 2kl2 NOTCHED STRINGER INSTALL.MFIRESTOPATIOD SPIN OF $TIMM (3)2d2MFMMTYP. CBM OF ENCLOSED USAIRE SPACE I UNDER STAIR W TYP T GYP. SO. AT ALL WALLS AND --L-�V- STAIRKID WALLMID CEINGOFENCLOSED USAIIIESPACE UNDERSTAIR - LANDING/STRINGER DETAIL HANDRAIL STRING E R/LANDING DETAIL SCALE! 11/2"- 1'.0" SCALE: 11/2"- V-0" SCALE: 11/2"- F-0" 0021 " DE�ELOFMKI Do NOT SCALE TASE DRAVW.5 "SPJFY BULDW. OREWATION UTA CONTWTOR AND SITE FLAW, BEFOW CONSTILICT TIESE DRAWWA DO NOT C AN SKCFIC ff,001ATION FOR Y 8TRICTRAL ELV�s (TO Im PROV= By EW.NEER OF IFECOM ANY VISOWEPANCY CDR*NMM ORIEWATIOK ETCJ BEMB TWSE DRAl*W AIV ASSOCIATED DRALM5 ZZ ' TE )RAMW36 SWALL BE WPORTED TO CONTRACTOR T 04CE 410 NO COWSTRX ION $14ALL PIISOMD LNTL COIMCTED. TA COWTRACIOR ASStMS T�E PESPOWBILITY TO MEET ALL PEOU"REMWTS OF LOCAL BU LOW OFFICIALS 4 TO COMLY UTA STATE L 51JILDW� CODES o LZL, --4 > Lu > LL 7 EMMM I 40M E FEAM ft C) CD z �--q cc ce) CD C*-) , 0 — =:) �;A co (D C) 04 C:) ZS min 7 wwmw. I FM j VERSION: 5.0] awmm MISC. DETAILS JHEErt A-3.31 EXTERIOR FIBER CEMENT SIDING OVER 7YVW OR EQUAL HOUSEWRAP OVER ExIERIOR SHEATHING AND FRAMING PER STRUCTURAL DWG& S* WIDE SELF ADHERING, SELF HEALING WATERPROOF MEMBRANE UNDER 2 LAYERS OF BUILDING PAPER - TAPE4EALCORNERS CORROSION RESISTANT METAL HEAD RASHING WITH WRAPPED ENDS OVER BACKER MATERIAL INTERIOR rWIm3EUF ADHERING, SELF HEAUNGWATGRPROOF MEMBRANE SHIMSPACIEPER MANUFACTUIIES RECOMMENDATIONS CAULKING-TRICAL WINDOW ASSEMBLY INSEALLED WITH CONTINUOUS SEALANT BEAD AT RANGE PRIOR TO INSTALLATION NOTE: WINDOW ASSEMBLY TO BE FASIENED TO STRUCTURE PER WINDOW MANUFACTUIM INSTALLATION REQUIREMENTS AND RECOMMENDATIONS HEAD AT FRAME WALL 'CALE: 3". '-0" HORIZ LAP SCING INSTALLED PW MFRS INSTRUCTIONS 0/ BUILDING PAPER O/SHEATHING AS OCCURS TPER STRUCTURAL DETAILS) STUCCO FINISH COAT 0/ FOAM TRIM SEE ELEVA71ON — Ix WD. TRIM SEAl" — bRES DR, JAMB JAMB STRIP — GARAGE DOOR OVERHEAD GARAGE DOOR JAMB SCALE: 11/2"- F-O' FOR FRIAG. PER STRUCTURAL DETAILS GYP. ED. —2.6 EXTERIOR SELF AWERING, SELF HEALING WATERPROOF MEMBRANE SILL DAM400NFKAE 4r MIN. UP JAMES EXTERIOR GRADE SEALANT OVER FIBER MY24 SIDING OVER TVVEr OR EQUAL HOUSEWRAP OVER eaERIOR SHEATHING AND FRAMING PER HORIZ LAP SDING INSTALLED PER MFIVS INSTRucncHs 01 BUILDING PAPER 0/ SHEAIHING AS OCCURS (PER STRUCTURAL DETAILS) LAP BUILDING PAPER MIN T 0/ GSM DRIP EDGE HASHING 24 GA GSM DRIP EDGE FLASHING — ICE & WATER SHIELD AT CORNEERS. ExIEND or UP WALL WOOD TRIM SEE EUW FOR SIZE -- INTERIOR VAN" ASSDABLY INSIALLED WITH CONTINUOUS SEALANT MAD AT RANGE PRIOR TO INSTALLATION CAULDr—TYPICAL DO WOOD DAM INSTALL PLYWOOD, PAINTED RACK BEHIND WINDOWS AT DORMERS, TYP. V NOTE: WINDOWASSEMBLYTO BE FASrENEDTO STRUCTURE PER WINDOW MANUFACTURERS INSTALLATION REQUIREMENTS AND RECOMMENDATIONS SILL AT FRAME WALL SCALE: 3"- V-0" VFOR FRIAG. PER STRUCTURAL DErAJLS ,GYP7.BD. 2x RES DR. HEAD GARAGE DOOR GARAGE DOOR TRACK OVERHEAD GARAGE DOOR HEAD SCALE: 11/2"- Y-V EXTERIOR FIR CEMENT SIDING OVER 7YVEC OR EQUAL HOUSEWRAP OVER EXTERIOR SHEATHING AND FRAMING PER STRUCTURAL DWGS. CWIDE SELF ADH9WG, SELF HEALING WATERPROOF MEVARANE OVER BOTH LAYERS OF BUILDING PAPER EXTERIOR GRADE SEALANT OVER BACKER MATERIAL 6"WIDESELFADHEItING, SELF HEALING WATERPROOF MEMBRANE INTERIOR WIM SPACE PER AANUFACFURES' MtOMMENDATIONS :AULKING-TYPICAL NINDOW ASSEMBLY WALLED WITH DONTINUOUS SEALANT SEAD AT RANGE PRIOR To — NOTE: WINDOW ASSEMBLY TO BE FASTENEI) TO STRUCTURE PER W14DOW MANUFACTURERS INSTALLATION REQUIREMENTS AND RECOMMENDATIONS JAMB AT FRAME WALL SCALE: 3"- V-V MANUR 0/ GRADE ICT. SHEATHING SIZE I MOGTOP W FINISH SLIDING GLASS DOOR HEAD SCALE: 3"- '-V GW21 AM DEI-ELORW DO NOT SCALE TOESE DR4*W �ERFY ULM ORI ATION VTW CONTRACTOR AND WE PLANS BEPORE OINSTRUCT THESE DRAWWA DO NOT CONIAN SPECFIC NOWATTON FOR SIRXTLRAL ELEMNIS (TO BE PROVIDED BY ENWEER OF REECORDI ANY DLCREPANCY (DM'00*. OROITATION. ETC.) BETiEEN T�UE CRAMM AND TNE ASSOCIATED DRAWWA �/a SITE DRAJOW &4AL BE REPORTM TO CONTRACTOR 7 ONCE AND NO CONSTRC JON SNALL PIWCEEO tNTL CORRECTED. TNE CONTRACTOR ASSV'ES T�E RESPOOBILITY TO MEET ALL REaj 5 OF LOCAL BUILDW OWGIALS 4 TO CC�IPLY VTW STATE BUILDIM CODEb 4-J 0 LLI V > Flo LL, 0 0 �q CL RLMME FEMONS: C) c) 0 5 d, 0 F —1 L I VERSION: 5.01 m DETAILS am# A-3.41 GENERAL STRUCTURAL NOTES: 1. ALL WORK SHALL CONFORM TO THE 2023 8th EDITION OF THE FLORIDA (INTERNATIONAL) RESIDENTIAL CODE AND APPLICABLE COUNTY CODE AMENDMENTS. STANDARDS LISTED IN STRUCTURAL NOTE SECTIONS REFER TO THE VERSION AND EFFECTIVE DATE IDENTIFIED IN THE REFERENCED STANDARDS CHAPTER IN THE GOVERNING BUILDING CODE NOTED ABOVE. 2. THE STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS. SHOULD CONFLICTS EXIST BETWEEN THE DRAWINGS AND THE STRUCTURAL NOTES, THE STRICTEST PROVISION SHALL GOVERN. 3. THE STRUCTURAL DRAWINGS FORM AN INTEGRAL PART OF CONTRACT DOCUMENTS, WHICH INCLUDE ARCHITECTURAL. STRUCTURAL, MECHANICAL, ELECTRICAL, AND CIVIL/SITE DRAWINGS. COORDINATE THE STRUCTURAL DRAWINGS WITH THE REQUIREMENTS SHOWN IN THE OTHER COMPONENTS OF THE CONTRACT DOCUMENTS. 4. TYPICAL DETAILS AND OTHER SECTIONSIDETAILS APPLY TO CONDITIONS THAT ARE SIMILAR TO THE CONDITIONS DESCRIBED IN THE SECTIONS/DETAILS, EVEN IF THEY ARE NOT SPECIFICALLY REFERENCED ON THE PLANS. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS SEQUENCES AND PROCEDURES OF CONSTRUCTION, INCLUDING BU`T NOT LIMITED TO TEMPORARY SHORING AND BRACING. 6. DO NOT SCALE STRUCTURAL DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR, CONTACT THE ENGINEER. 7. CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF OSHA AND THE LOCAL GOVERNING CODES, CURRENT EDITION, AND ALL REQUIREMENTS SPECIFIED IN THE CODES SHALL BE ADHERED TO AS IF THEY WERE CALLED FOR OR SHOWN ON THE DRAWINGS. THIS SHALL NOT BE CONSTRUED TO MEAN THAT REQUIREMENTS SET FORTH ON THE DRAWING MAY BE MODIFIED BECAUSE THEY ARE MORE STRINGENT THAN THE CODE REQUIREMENTS OR BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED BY CODE. 8. THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS. ANY DEVIATIONS OR DISCREPANCIES ON THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER OF RECORD. BACK CHARGES WILL NOT BE ACCEPTED, REGARDLESS OF FAULT, WITHOUT PRIOR NOTIFICATION BY BUILDER WITHIN 48-HOURS AND INVESTIGATION BY FIELDSTONE. 9. THE TERMS'CONCRETE SCREW ANDWASONRY SCREW SHALL BE USED INTERCHANGEABLY WITHIN THESE DRAWINGS. CONCRETE/MASONRY SCREWS AS GENERICALLY SPECIFIED WITHIN THESE DRAWINGS SHALL REFER TO ONE OF THE FOLLOV41NG ACCEPTED MANUFACTURER PRODUCTS: SIMPSON STRONG TIE TITEN TURBO, GENUINE TAPCON, OR HILTI KWIK-CON 11. 10. CONTENT LINKED WITHIN OR CODES THAT MAY BE SHOWN WITH THE DRAWING SET ARE FOR INFORMATIONAL PURPOSES ONLY AND THE PROFESSIONAL SEAL ON THIS DRAWING DOES NOT APPLY TO CONTENT CONTAINED WITHIN ANY OR CODES. 11. POST INSTALLED EPDXY ANCHORAGE GENERICALLY NOTED WITHIN THESE DRAWINGS SHALL BE EITHER SIMPSON STRONG TIE SET-3G, OR HILTI Hrr-HY-150 DESIGN CRITERIA: 1. BUILDING RISK CATEGORY 2. VERTICAL LOADING: ROOF TOP CHORD LIVE LOAD �20 PSF (REDUCIBLE) ROOF TOP CHORD DEAD LOAD =7 PSF ROOF TOP CHORD DEAD LOAD CTILE) =15 PSF ROOF BOTTOM CHORD LIVE LOAD (w/ STORAGE) =20 PSF ROOF BOTTOM CHORD LIVE LOAD (w/o STORAGE) � 10 PSF ROOF BOTTOM CHORD DEAD LOAD =10 PSF FLOOR LIVE LOAD -40 PSF FLOOR LIVE LOAD (SLEEPING ROOMS) =30 PSF FLOOR DEAD LOAD -_15 PSF DECK/BALCONY LIVE LOAD =40 PSF NOTE TO TRUSS & I -JOIST MANUFACTURERS - ROOF & FLOOR SYSTEM DELEGATED DESIGN SHALL CONFORM TO THE FOLLOWING DESIGN STANDARDS: LOCATION I TOTAL LOAD LIVE LOAD I MAX TOTAL DEFLECTION I ROOF TRUSSES 1_1240 L/240 I FLOOR JOISTSITRUSS L/360 i L/480 NOTES: 1. MAXIMUM TOTAL LOAD DIFFERENTIAL DEFLECTION BETWEEN ADJACENT PARALLEL MEMBERS SHALL BE 5/8" 2. ANY MEMBER SUPPORTING BRICKIMASONRY SHALL BE LIMITED TO A TOTAL LOAD DEFLECTION OF L/600 3. FIELDSTONE AE CANNOT BE HELD RESPONSIBLE FOR ANY STRUCTURAL ISSUES RELATED TO ANY BUILDING COMPONENT IF COMPONENT SHOP DRAWINGS ARE NOT SUBMITTED TO FAE FOR REVIEW PRIOR TO FABRICATION, DELIVERY. OR INSTALLATION 3. LATERAL LOADING WIND CRITERIA: TORNADO WIND SPEED BASIC WIND SPEED =140 MPH EXPOSURE CATEGORY INTERNAL PRESSURE COEFFICIENT 0.18 (ENCLOSED) SEISMIC CRITERIA SITE CLASS SEISMIC DESIGN CATEGORY 4. EARTH PRESSURE LOADING: ALLOWABLE SOIL BEARING CAPACITY TOTAL LOADS (INCLUDING WIND & SEISMIC) =2000 PSF LATERAL EARTH EQUIVALENT FLUID PRESSURE WALLS UNBRACED AT TOP -=40 PCF WALL BRACED AT TOP -55 PCF 6. GUARDRAILA-IANDRAIL LOADING: ALL GUARDRAILMANDRAILS SHALL MEET 200 UBS (MINIMUM) CONCENTRATED FORCE APPLIED IN ANY DIRECTION. IN -FILL COMPONENTS OF GUARDRAIL SHALL MEET 50 PSF. THESE LOADS ARE TO BE EVALUATED INDEPENDENTLY AND ARE NOT TO ACT CONCURRENTLY WITH ANY OTHER LIVE LOAD. DEFLECTION OF GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICES (ICC-ES) AC 273 - 'ACCEPTANCE CRITERIA FOR HANDRAILS AND GUARDS." CONCRETE NOTES' 1 . STRUCTURAL CONCRETE HAS BEEN DESIGNED IN ACCORDANCE PER ACI 332 "RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". 2. CONCRETE PRODUCTION AND PLACEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI 332 "RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" EXCEPT AS MODIFIED BY STRUCTURAL REQUIREMENTS NOTED ON THE DRAWINGS. 3. CEMENT SHALL CONFORM TO ASTM C1 50 "SPECIFICATION FOR PORTLAND CEMENT."CONCRETE SHALL BE NORMAL WEIGHT, UNLESS INDICATED OTHERWISE- 4, CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33 "SPECIFICATION FOR CONCRETE AGGREGATES." 6. REINFORCING SHALL CONFORM TO ASTM A-615 GRADE 60. 6. REINFORCEMENT SHALL BE FABRICATED AND ERECTED ACCORDING TO THE ACI STANDARDS: "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT", ACI 315 - AND 'MANUAL OF ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES', ACI 315R. 7. REINFORCING STEEL AND WELDED WIRE FABRIC SHALL BE PLACED WITH MINIMUM CONCRETE COVER AND TOLERANCES AS FOLLOWS: SLAB4014-GRADE: WITHIN UPPER 2/3 OF SLAB AND 3/4" MINIMUM COVER AT INTERIOR CONDITIONS; 1-1 /2" MINIMUM COVER AT EXTERIOR CONDITIONS CONCRETE (FOLINDATION) AMNST EARTH: 3" FORMED CONCRETE: 1-1/2- (#5 REBAR OR SMALLER) 2- (#6 REBAR OR LARGER) TOLERANCE: +/- 3/8" 8. REINFORCING STEEL SHALL NOT BE CUT, BENT OR STRAIGHTENED IN THE FIELD UNLESS APPROVED BY THE STRUCTURAL ENGINEER OR AS INDICATED ON THE DRAWINGS. 9. WELDING OF REINFORCING STEEL IS PROHIBITED UNLESS SPECIFICALLY DETAILED. WELDING WHERE DETAILED SHALL CONFORM TO AWS D1.4 SPECIFICATION. CONCRETE NOTES (CONTINUED): 10. CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH AS FOLLOWS: FOUNDATIONS & FOUNDATION WALLS: 2500 PSI SLAB -ON -GRADE & CONCRETE BEAMS: 2500 PSI 11. CONTRACTOR SHALL TIE REINFORCING STEEL SECURELY IN PLACE PRIOR TO PLACING CONCRETE AND PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THEIR POSITION WITHIN SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. INSERTING DOWELS INTO WET CONCRETE IS NOT PERMITTED. ANCHOR RODS AND STEEL INSERTS SHALL BE SET BY TEMPLATE TO WITHIN A 10TOLERANCE IN ANY DIRECTION NTH MINIMUM EMBEDMENT AND EXACT PROJECTION INDICATED ON THE DRAWINGS, PRIOR TO PLACING CONCRETE. 12. HOOKED BARS SHALL BE STANDARD 90 DEGREE HOOKS PER ACI UNLESS NOTED OTHERWISE ON THE DRAWINGS. MINIMUM LAP SPLICE SHALL BE CLASS B PER ACI 31 S. LOCATION OF LAP SPLICES SHALL BE AS INDICATED ON CONSTRUCTION DOCUMENTS. 13. DOWELS INTO FOUNDATION SHALL MATCH SIZE AND SPACING OF VERTICAL REINFORCEMENT AT ALL COLUMNS, PIERS AND WALLS, UNLESS OTHERWISE NOTED. 14. CONTRACTOR SHALL OBTAIN APPROVAL PRIOR TO PLACING OPENINGS OR SLEEVES NOT SHOWN ON THE DRAWINGS, THROUGH ANY STRUCTURAL MEMBER. 15. ONE OF THE FOLLOWING CONCRETE SLAB ON GRADE CRACK CONTROL METHODS SHALL BE USED (CONTRACTOR PREFERENCE): CONTROL JOINTS: SHALL BE FORMED, SAWED, OR TOOLED TO A I" MINIMUM DEPTH WITHIN 24 HOURS OF CONCRETE PLACEMENT. MAXIMUM JOINT SPACING FOR UNREINFORCED SLAB IS AS FOLLOWS: 3-1/2"SLAB: 8 FEET D.C. EACH DIRECTION 4" SLAB: 10 FEET D.C. EACH DIRECTION WELDED WIRE FABRIC (W.W.F.) 6X6-W1.4XW1A WELDED WIRE FABRIC SHALL BE FURNISHED IN FLAT SHEETS (ROLLS NOT PERMITTED) AND SHALL CONFORM TO ASTM A-ID64 AND HAVE A MINIMUM SIDE AND END LAP OF 8 INCHES. MICRO- OR MACRO- SYNTHETIC FIBER REINFORCEMENT FIBER LENGTHS SHALL BE 1/2'TO 2-114" IN LENGTH. DOSAGE AMOUNT SHALL BE FROM 3/4 TO 3.0 POUNDS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1 116. THE MANUFACTURER/SUPPLIER SHALL PROVIDE CERTIFICATION OF COMPLIANCE NTH ASTM C1 116 WHEN REQUESTED BY THE BUILDING OFFICIAL. 16. CONTROL JOINTS SHALL BE FURNISHED WITH A FULL-LENGTH KEYWAY CENTERED ON MEMBERS. WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY SHALL BE 25% OF THE CROSS-SECTION DIMENSION OF THE MEMBER AND MINIMUM 1-1/2 INCHES INTO THE FIRST POUR OF CONCRETE. 17. PROVIDE POCKETS OR RECESSES IN CONCRETE WORK FOR COLUMNS AND BEAMS AS REQUIRED EVEN IF NOT SHOWN ON THE DRAWINGS. PROVIDE CONCRETE FILL AFTER BEAM ERECTION. 18. CURING OF CONCRETE SURFACES SHALL CONFORM TO ACI 308.1 "STANDARD SPECIFICATION FOR CONCRETE CURING" AND ACI 308R 'GUIDE TO CURING CONCRETE". FOUNDATION NOTES: 1 . CONTRACTOR SHALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES AND FIELD MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE. 2. TOP OF SPREAD FOOTING ELEVATIONS NOTED ON PLAN ARE MINIMUM ELEVATIONS. IN ALL CASES FOOTINGS ARE TO BEAR ON UNDISTURBED NATURAL SOILS 08 ENGINEERED FILL HAVING A MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2000 PSF. 3. SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING, FOUNDATIONS POURED AGAINST THE EARTH REQUIRED THE FOLLOWING PRECAUTIONS: SLOPE SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING BEFORE AND DURING CONCRETE PLACEMENT. PROVIDE POLYETHYLENE VAPOR RETARDER COMPLYING WITH GOVERNING BUILDING CODE LISTED ON THIS SHEET AGAINST SOILS WHERE CONCRETE IS TO BE PLACED: LAP ALL EDGES 6 INCH (MINIMUM) AND SEAL WITH ADHESIVE. 4. WHERE FOOTING STEPS ARE NECESSARY, THEY SHALL BE NO STEEPER THAN ONE VERTICAL TO TWO HORIZONTAL U.N.0- 5. FOOTINGS SHALL BE CENTERED UNDER COLUMNS AND WALLS UNLESS SPECIFICALLY DETAILED OTHERWISE ON THE DRAWINGS. 6. NO FOOTINGS OR SLABS SHALL BE PLACED ON OR AGAINST SUB -GRADE CONTAINING FREE WATER, FROST OR ICE. SHOULD WATER OR FROST, HOWEVER SLIGHT, ENTER A FOOTING EXCAVATION AFTER SUB -GRADE APPROVAL, THE SUB -GRADE SHALL BE RE -INSPECTED BY THE GEOTECHNICAL ENGINEER/ TESTING LABORATORY AFTER REMOVAL OF WATER OR FROST. 7. CONTRACTOR SHALL FURNISH ALL REQUIRED DE -WATERING EQUIPMENT TO MAINTAIN A DRY EXCAVATION UNTIL BACKFILL IS COMPLETE. 8. A GEOTECHNICAL ENGINEER REGISTERED IN THE STATE OF WORK PERFORMED SHALL INSPECT THE CONDITION AND ASSURE THE ADEQUACY OF ALL SITE PREPARATION, SUBGRADES, FILLS, BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS AND WALLS. HE SHALL SUBMIT REPORT TO THE ARCHITECT/ENGINEER DESCRIBING HIS INVESTIGATIONS OF ANY NON -CONFORMING WORK BACKFILLING: 1 . DO NOT PLACE BACKFILL AGAINST FOUNDATION WALLS - DESIGNED AS SUPPORTED AT TOP AND BOTTOM - UNTIL BASEMENT LEVEL AND FIRST FLOOR SYSTEM ARE IN PLACE. SHORE AND/OR BRACE WALLS AS REQUIRED IF BACKFILLING OPERATIONS ARE TO BE CARRIED OLT PRIOR TO PLACEMENT OF FLOOR SYSTEM. 2. WHERE BACKFILL IS TO BE PLACED ON BOTH SIDES OF FOUNDATION WALLS, PROVIDE A BALANCED BACKFILL AGAINST FOUNDATION WALLS TO ELIMINATE LATERAL LOAD EFFECTS, OR PROVIDE NECESSARY TEMPORARY LATERAL SUPPORT TO THE TOP OF THE WALL UNTIL PERMANENT SUPPORT IS INSTALLED. 3. BACKFILL MATERIAL SHALL CONSIST OF CLEAN, WELL GRADE GRANULAR SOILS, FREE OF ORGANIC MATERIAL AND BE COMPACTED TO 95% OF MAXIMUM DENSITY, AS DETERMINED BY THE MODIFIED PROCTOR METHOD (ASTM D1557), IN UFTS NOT EXCEEDING 8 INCHES. MASONRY NOTES: 1. CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530, "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 530.1, -SPECIFICATIONS FOR MASONRY STRUCTURES.- 2. CONCRETE MASONRY SHALL CONFORM TO ASTM C90 AND HAVE A MINIMUM COMPRESSIVE STRENGTH Prn = 1.500 PSI U-0-N. MASONRY SHALL HAVE A TEXTURE SUITABLE FOR STUCCO APPLICATIONS WHERE ARCHITECTURAL DRAWINGS INDICATE STUCCO APPLICATION, 3. CONCRETE MASONRY UNITS SHALL BE LAID IN RUNNING BOND. 4. MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270 WITH MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. MORTAR BELOW GRADE SHALL BE TYPE M. ELSEWHERE MORTAR MAY BE EITHER TYPE M OR S UNLESS SPECIFICALLY INDICATED OTHERWISE. USE EITHER PORTLAND CEMENT/LIME OR MASONRY CEMENT FOR MORTAR. 5. GROUT SHALL CONFORM TO ASTM C476 WITH MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2,500 PSI. 6, STEEL BAR REINFORCEMENT SHALL CONFORM TO ASTM A61 5, GRADE 60. T VERTICAL CELLS CONTAINING REINFORCING AND GROUT SHALL FORM A CON nNUOUS CAVITY, FREE OF MORTAR DROPPINGS. 8. VERTICAL CMU WALL REINFORCING SHALL BE AS NOTED ON THE DRAWINGS. DOWELS TO CONCRETE FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL REINFORCING UNLESS NOTED OTHERWISE. REINFORCE CMU CORE AT CORNERS, EACH SIDE OF CONTROL JOINTS AND EACH SIDE OF WALL OPENINGS WITH (1)-#5 CONTINUOUS VERTICAL REINFORCING BARS.. 9. HORIZONTAL BOND BEAM AND VERTICAL REINFORCING SHALL BE CONTINUOUS U.O.N. LAP SPLICE REINFORCING PER THE SCHEDULE OR USE MECHANICAL SPLICES ADEQUATE FOR 125% OF SPECIFIED YIELD STRENGTH OF THE BAR. LAP VERTICAL REINFORCEMENT WITH MINIMUM DOWELS OF SAME SIZE AND SPACING THAT HAVE BEEN PREVIOUSLY INSTALLED IN THE FOUNDATIONS. DOWEL EMBEDMENT IN CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE CONCRETE NOTES. BAR SIZE LAP SPLICE LENGTH BEND DIAMETER ACI HOOK #4 29' 3- 191 #5 25" 3-3/4" 10.1 #6 1., 4-1/2" 11. MASONRY NOTES (CONTINUED): 10. REINFORCING BARS SHALL BE HELD IN POSITION BY WIRE TIES OR OTHER APPROVED MEANS TO ENSURE DESIGN LOCATION AND LAP. PLACE BARS AND LAP PRIOR TO GROUTING. 11. GROUTING OF MASONRY WALLS SHALL CONFORM TO RECOMMENDED PROCEDURE FOR "LOW LIFT GROUTING" OR"HIGH LIFT GROUTING"AS OUTLINED IN THE NCMA-TEK 3-2A - GROUTING FOR CONCRETE MASONRY WALLS AND ACI 530/ASCE 5 SPECIFICATION FOR MASONRY STRUCTURES- GROUT LIFTS SHALL NOT EXCEED 5 FEET WITHOUT MECHANICALLY CONSOLIDATED (VIBRATED) GROUT POURS. 12. LIFTS OF GROUT SHALL BE KEYED 4 INCHES INTO THE PREVIOUS COURSE OF MASONRY BELOW. 13. MASONRY BELOW GRADE SHALL BE GROUTED SOLID. 14. CONTRACTOR SHALL BRACE MASONRY WALLS TO RESIST WIND LOADS UNTIL FLOOR$ AND ROOFS ARE IN PLACE, AND THE MASONRY HAS REACHED 75% OF THE REQUIRED STRENGTH FM. BRACING SHALL BE PROVIDED IN ACCORDANCE WITH OSHA - CONSTRUCTION SAFETY STANDARDS FOR MASONRY WALL BRACING AND NCMA TEK 3-4B -BRACING CONCRETE MASONRY WALLS DURING CONSTRUCTION." WOOD FRAMING NOTES: 1 � STRUCTURAL SAWN LUMBER, STRUCTURAL COMPOSITE LUMBER, AND CONNECTIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION." INDS) 2. PLYWOOD HAS BEEN DESIGNED IN ACCORDANCE WITH "PANEL DESIGN SPECIFICATION."AND SHALL CONFORM TO"VOLUNTARY PRODUCT STANDARD PS1 CONSTRUCTION AND INDUSTRIAL PLYWOOD." 3. ORIENTED STRAND BOARD (OSB) SHALL CONFORM TO -VOLUNTARY PRODUCT STANDARD PS2 PERFORMANCE STANDARD FOR WOOD -BASED STRUCTURAL -USE PANELS". 4. ALL BEAMS AND HEADERS SHALL BE (2)-PLY U.N.O. 5. WOOD SILL PLATES AND WOOD WALLS SUPPORTED ON CONTINUOUS CONCRETE OR MASONRY SHALL BE ANCHORED WITH 1/2" DIAMETER CAST -IN -PLACE ANCHOR BOLTS WITH 7" EMBEDMENT, 4- (MINIMUM) AND 12- (MAXIMUM) FROM END OF SILL PLATE(S), LOCATED WITHIN THE MIDDLE THIRD OF THE SILL PLATE, NTH NU`r AND 3-x3-XO.229- WASHERS AT THE ANCHOR SPACING BELOW: MAXIMUM ANCHOR BOLT SPACING= Z-O"O-C. REFER TO "PRE -APPROVED FIELD REPAIR NOTES' SECTION FOR ALTERNATE ANCHORAGE APPROVALS. FOR OTHER ANCHORS NOT LISTED, SUBMIT TO ENGINEER OR RECORD FOR REVIEW. 6. ALL LUMBER IN CONTACT WITH EARTH, CONCRETE, OR MASONRY - AND WOOD BEAMS POCKETING INTO CONCRETE OR MASONRY WALLS HAVING CLEARANCES LESS THAN I/Z'ON TOP, SIDES. AND END(S) SHALL BE PRESSURE TREATED OR SEPARATED WITH AN IMPERVIOUS MOISTURE BARRIER. 7. STRUCTURAL SAWN LUMBER SHALL BE SPRUCE -PINE -FIR NOA /NO.2 OR BETTER U.N.O. WITH BASE DESIGN VALUES: F,= 875 PSI F� = 425 PSI FT = 450 PSI F�= 1150 PSI F,� 135 PSI E= 1400 KSI WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. 8. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED V41TH DOUBLE (2X) TOP PLATES INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS. END JOINTS IN DOUBLE (2X) TOP PLATES SHALL BE OFFSET AT LEAST 24 INCHES AND SHALL BE NAILED WITH NOT LESS THAN (8)-O.162"x2-1/2" FACE NAILS ON EACH SIDE THE JOINT. DOUBLE (2X) TOP PLATES OF EXTERIOR WALLS AND INTERIOR LOAD BEARING WALLS SHOWN ON DRAWINGS SHALL BE SOUTHERN YELLOW PINE NO.2 OR BETTER WITH BASE DESIGN VALUES: FB= 1100 PSI F�= 565 PSI FT= 675 PSI F�= 1450 PSI Fv= 175 PSI E= 1400 KSI WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. 9. STRUCTURAL COMPOSITE LUMBER SHALL CONFORM TO ASTM D 5456 WITH THE FOLLOWING ALLOWABLE DESIGN STRESSES MICRIDULANI LVL PARALLAM PSL r) TIPABERSTRAND LSL E = 2000 KSI E 1800 KSI E = 1300 KSI F, = 2600 PSI F, 2400 PSI F, = 1700 PSI I') - 'BOOZER BEAM 2.1 E' ARE AN ACCEPTED ALTERNATE TO PSL COLUMNS SPECIFIED ON PLANS PROVIDED THE'BOOZER BEAM 2.1 EAS OF EQUAL OR GREATER SECTION DIMENSION TO THE PSL COLUMN AND OF EQUAL OR LESSER HEIGHT 1O.FLOOR SHEATHING SHALL BE 23/32 INCH, APA RATED SHEATHING. 48/24 MIN., EXPOSURE 1. INSTALL WITH THE LONG DIMENSION OR STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. PANEL EDGES SHALL BE TONGUE -AND -GROOVE. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO SUPPORTING MEMBERS. ADHESIVE SHALL MEET APA SPECIFICATION AFG.01, APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. PROVIDE 0.1 31"x2-1/2" COMMON NAJLS AT 6 INCH O.0 ALONG SUPPORTED PANEL EDGES AND 12 INCH O.0 AT INTERMEDIATE SUPPORTS. 11. FOR INTERIOR WALL HEADERS PROVIDE (l)-2X JACK STUD AND (l)-2X KING STUD U.N.O. ON DRAWINGS. 12. FOR EXTERIOR WALL HEADERS PROVIDE (l)-2x JACK STUD AND (l)-2x KING STUD, MINIMUM, REFER TO CHART BELOW U.N.0 ON DRAWINGS: WINDSPEED OF 140 EXP_ C FWALL HEIGHT 8FT 9FT 1OFT STUD SIZE HEADER SPAN (FT) 4 1J/1K 1J/IK 1J/1K 6 1J/IK 1J/1K 1J/2K 8 1J/IK 1 J/2K 1 J/3K 10 1 J/2K 1 J/2K I J/4K 2X4 12 1 J12K 1 J/3K I J/4K 14 U/2K I J/4K ENG 16 tJ/3K 1 J/4K ENG 18 1 J/3K ENG ENG WINDSPEED OF < = 140 EXP. C WALL HEIGHT 8FT 91 1 OFT STUD SIZE HEADER SPAN (Fr) 4 1J/IK IJ/1K 1J1IK 6 1J/1K 1J/1K 1J/1K 8 IJ/1K 1J/1K IJ/1K 10 1J/1K 1J/1K 1J/1K 2X6 12 1J/1K 1J/1K 1JAK 14 1J/FK 1J/1K IJJIK 16 1J/1K 1J/1K 1J/1K 18 1,111K 1J1IK 1,111K 13. WALLS SHOWN ON THE FRAMING PLANS AR E LOAD BEARI NG WALLS: WALLS NOT SHOWN ON STRUCTURAL FRAMING PLANS ARE INTERIOR NON -LOADING BEARING PARTITION WALLS. 14. LOAD BEARING WALLS SHALL BE CONSTRUCTED WITH 2X STUDS AT 16" D.C. MAXIMUM U.N.O. NON -LOAD BEARING PARTITION WALLS SHALL BE CONSTRUCTED WITH 2X OR METAL STUDS (18 GA. MIN.) @ 24- D.C. MAXIMUM. 15. STUD COLUMNS UNDER LOAD BEARING POINTS OF GIRDERSIBEAMS SHALL MATCH THE GIRDERIBEAM PLY COUNT WITHIN I/Z'TOLERANCE (2-PLY STUD COLUMN MINIMUM). SOLID BLOCK ALL GIRDERIBEAMS THRU FLOOR SYSTEMS AND TO THE FOUNDATION. 16. WHEN NOT SHOWN ON DRAWINGS OR DETAILS, THE NAILING SCHEDULE FOR WOOD FRAMING ELEMENTS SHALL COMPLY WITH THE IFIC TABLE R602.3(i). 17.FLOOR SYSTEMS ARE DESIGNED BY THE TRUSS AND/OR WOOD I- JOIST MANUFACTURER'S DELEGATED ENGINEER AND BE IN CONFORMANCE WITH THE LOADS & DEFLECTIONS IDENTIFIED IN THE DESIGN CRITERIA NOTES SECTION. INSTALL PER MANUFACTURER's RECOMMENDATIONS, NOTES, AND DETAILS. FLOOR FRAMING CONCEPT LAYOUTS SHOWN WITHIN THE DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY TO DEPICT FLOOR SYSTEM -TO -WALL CONNECTIONS. CHANGES TO THE CONCEPTUAL FLOOR LAYOUT SHOWN IS NOT PERMITTED WITHOUT A LE17ER AND REVIEW FROM THE ENGINEER OF RECORD. PREFABRICATED WOOD kJOIST SHALL CONFORM TO ASTM D 5055. JURISDICTION SPECIFIC NOTES: I . FOR PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO LANAIS, PORCHES, AND BALCONIES A 1/2' (MINIMUM) EXTERIOR GRADE SOFFIT BOARD WITH A CEMENTITIOUS KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE REQUIREMENTS OF ASTM C932 TO GIVE THE CEILING WATER RESISTANCE. THE SOFFIT BOARD PRODUCT SHALL BE ATTACHED PER MANUFACTURER SPECIFICATIONS TO BE IN COMPLIANCE WITH R703.1. 2. THE SOFFIT DESIGN PRESSURE IS AS NOTED IN THESE DOCUMENTS. NTH KAYCAN VINYL SOFFIT INSTALLED IN ACCORDANCE WITH MANUFACTURER'S REQUIRMENTS AND ICC-ES EVALUATION REPORT ESR-1495 THE SOFFIT WILL COMPLY NTH R7031. PRE-ENGINEERED ROOF TRUSS NOTES: 1 . ROOF TRUSS SHOWN ON STRUCTURAL DRAWINGS IN CONCEPTUAL ONLY TO ILLUSTRATE TRUSS -TO WALL CONNECTIONS AND DOES NOT SERVE AS A ROOF TRUSS DESIGN, ROOF TRUSSES SHALL BE DESIGNED AND MANUFACTURED IN CONFORMANCE FOR THE INDICATED LOADS WITH ANSVTPI 1 "NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION." FINAL PRE-ENGINEERED ROOF TRUSS FRAMING LAYOUT AND DESIGNS TO BE BY ROOF MANUFACTURER'S DELEGATED ENGINEER. 2. ROOF TRUSSES SHALL BE DESIGNED FOR THE SUPERIMPOSED LOADS IDENTIFIED IN THE DESIGN CRITERIA NOTES SECTION. 3. THIS PLAN IS DEVELOPED FROM THE REVIEW OF MASTER TRUSS FILES. ANY LOT THAT DEVIATES FROM THE MASTER TRUSS FILE ON RECORD,OR FOR PLANS FIELDSTONE AE IS NOT CONTRACTED TO PERFORM TRUSS REVIEW ON. THE CONTRACTOR IS RESPONSIBLE TO ASSURE THE DIRECT COMPLIANCE OF TRUSS MANUFACTURER LAYOUT TO THESE DRAWINGS & VERIFY ALL TRUSS CONNECTORS ARE SUFFICIENT TO WITHSTAND THE UPLIFTILATERAL LOADS IMPOSED 4. TRUSS MANUFACTURER SHALL PROVIDE HANGERS AND CONNECTIONS ADEQUATE FOR LOADS AT ALL TRUSS -TO -TRUSS, TRUSS -TO -BEAM, AND BEAM -TO -TRUSS CONNECTIONS. 5. REFER TO ARCHITECTURAL DRAWINGS FOR TRUSS SHAPE, OVERHANG, DIMENSIONS, SLOPES, SPANS, DRAINAGE, BEARING WALL HEIGHTS, ETC. 6. THE POSITIONS, WEIGHTS, AND METHODS OF ATTACHMENTS OF ALL MECHANICAL UNITS, ELECTRICAL FIXTURES, PLUMBING, FIRE SPRINKLERS, ETC SHALL BE INCLUDED IN THE DESIGN OF THE TRUSSES BY THE TRUSS MANUFACTURER. SEE ARCHITECTURAL DRAWINGS FOR ATTIC ACCESS SIZE AND LOCATIONS. 7. SUPERIMPOSED LOADS FROM SECONDARY FRAMING (I.E. SOFFITS, PARAPETS, VALLEY FRAMING, UPPER TRUSSES, ETC) SHALL BE INCLUDED IN THE DESIGN OF SUPPORTING TRUSSES. 8. CONTRACTOR TO PROVIDE TRUSS BRACING PER BCSI-133 IN ADDITION TO PERMANENT BRACING SHOWN ON THE TRUSS DESIGN PROVIDED BY THE DELEGATED TRUSS ENGINEER. PRE -APPROVED FIELD REPAIR NOTES: 1. MISPLACED DOWEL REPAIR: THIS NOTE DESCRIBES ALTERNATES TO MITIGATE THE CASTING OF REBAR VERTICAL REINFORCEMENT AT AN INCORRECT LOCATION. IF THE WALL HAS NOT BEEN BUILT: DRILL AND EPDXY #5 REBAR (36" LG.) INTO THE THICKENED EDGE OF SLAB AT THE CORRECT LOCATION. AS WALL IN CONSTRUCTED, LAP REBAR IN ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12- LAP AT THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAMIBOND BEAM. COMPLETE GROUTING OF WALL. IF THE WALL HAS ALREADY BEEN BUILT: PRIOR TO GROUT PLACEMENT, OPEN THE WALL AT THE CORRECT LOCATION APPROXIMATELY 16" (H) x 4" (M AT FLOOR LEVEL. DRILL AND EPDXY #5 REBAR (32" LG.) INTO THE THICKENED EDGE OF SLAB. LAP VERTICAL REINFORCEMENT IN ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR NTH 12" LAP AT THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAM/BOND BEAM. COMPLETE GROUTING OF WALL. 2. MISSING/MISPLACED ANCHOR BOLT: ALTERNATE SILL PLATE ANCHORAGE SOLUTIONS INTO OONCRETE: A 1/2*x6" TITEN HD WITH 1-3/4" MINIMUM EDGE DISTANCE AND 6" MINIMUM END DISTANCE IS A DIRECT 1:1 REPLACEMENT FOR A 112" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT INTO CONCRETE. A 112"THREADED ROD SET-3G EPDXY 7" EMBEDMENT WITH 1-3/4" MINIMUM EDGE DISTANCE AND 7-1/2" MINIMUM END DISTANCE IS A DIRECT 1:1 REPLACEMENT FOR A 112" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT INTO CONCRETE. A 112"x6"TITEN HD WITH 1-3/4" MINIMUM EDGE DISTANCE AND 8" MINIMUM END DISTANCE AT 4'-8" D.C. REPLACES A 1/2" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT AT 6-0" D.C.; LIKEWISE A 1/2"XIS"TITEN HD WITH 1-3/4" MINIMUM EDGE DISTANCE AND 8" MINIMUM END DISTANCE AT 2-8 D.C. REPLACES A 112" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT AT 4'-0" D.C.. 3. SIMPSON MASA SILL ANCHORS MAY BE USED AS AN ALTERNATE TO THE ANCHOR BOLTS AND SPACING NOTED HERE -IN ACCORDING TO THE FOLLOWING TABLE: BASIC WIND SPEED (MPH) MAXIMUM SPACING � 140 6�0.. 140 11-6" 150 V-3. NOTES: 1. MASA SPACING BASED ON NO MORE THAN ONE IN THREE INSTALLED WITH ONE LEG INSTALLED VERTICALLY ATTACHED TO STUD 4, MISSING/MISPLACED TRUSS STRAP ANCHOR: REFER TO"MISSED TRUSS STRAP REPAIR" DETAIL WITHIN DRAWINGS. FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/8" BUT LESS THAN 1-1/2" FROM THE FACE OF THE TRUSS, A SHIM SHALL BE PROVIDED AND NAIL LENGTH INCREASED TO PENETRATE THROUGH BOTH PLYS OF MATERIAL (I.E. 3" LG. NAILS). WHEN GAP IS GREATER THAN 1-1/2". INSTALL NEW ANCHORS. 5. MASONRY WALL OVERHANGING SLAB BLOCK OVERHANG REPAIR , 5/8" NO REPAIR REOD 5/8" . OVERHANG < 1-112" GROUT SOLID BOTTOM 3 COURSE$ OF AFFECTED WALL LENGTH �1_1/2" CONTACT ENGINEER OF RECORD FOR REPAIR 6. NOTCHED TOP PLATES & STUDS REQUIRING REPAIR AT STLIDS: STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH GREATER THAN 25% OF THE WIDTH IN BEARING WALLS, OR 40% IN NON -LOAD BEARING WALLS: OR WHEN A HOLE IS DRILUED/BORED TO A DIAMETER EXCEEDING 4D% OF THE STUD WIDTH IN BEARING WALLS, OR 60% OF THE STUD WIDTH IN NON -BEARING WALLS. IF THE MAXIMUM HOLEINOTCH SPECIFICATIONS ARE EXCEEDED THEN A STUD SHOE MUST BE INSTALLED. STUD SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE HSS2-SDS1.5 WITH (1 2)-1/4"Xi -1 /2" SDS SCREWS. FOR MULTI -PLY 2X STUDS USE HSS2-"#"-SDS3 WITH (12)-1/4'13" SOS SCREWS, WHERE "#" CORRESPONDS TO TH E N UMBER OF STUDS IN THE MULTI -PLY. AT TOP PLATES: A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 50% OF THE PLATE WIDTH IS REMOVED FOR PIPING (EXCEPT WHEN THE SIDE OF THE WALL WITH THE NOTCH OR CUT IS COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT THROUGH. THE REQUIRED REPAIR IS A GALVANIZED 16-GAUGE METAL TIE THAT IS AT LEAST 1-1 /21* WIDE AND MUST BE FASTENED WITH (8)-16D NAILS ON EACH SIDE OF THE OPENING. . 000 Fi tone C.E C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERING: N 29349 13 IBRAHEM ELAYEB, PE P.E.# 91476 N BENJAMIN NIESE, PE IF P.E.# 86025 05/30/2024 DATE v fa E E 2 E z F Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FIL 33637 +1 813.466.3310 wKwfieldstoneae.com :4 z 0 z > 0-4 v) Lu Ld Iz 01 V) C) - U cc m 0 04 �ATINA III J �ORAVVN BY: I FA� ERSION: 5.Oj SHEET NAME COVER SHEET SHEET # SO.1-140_ 144 FFIOMIWCFSA maw 2STORY EnRIOR WONRY WAI FTG 11101/2023 F��10 C111110001111 GAIMILM --, PIM Fus CWMLPER FLM VISF.11I W11T.F13F.P91 FWM VDIT. W. ps K0111 AM Full 7— OMMFWW 031MR)DOG - -��: ; FOM PERRIM PIAPLAN FBPLM PER PLAN PER PLAN PER PLAN F03C WONRY CMER CDWMN 2/28/2022 F�Z3 V01114MMEPERFLAII WED00001101luaw rQ11119WOMAIE z- Rw ffia FMCIAGOROW)IOX Room L v-o- L 001MR111*90407.0111 L 1--o- L '17-4 �@ am -j�4 —(?P ow 2STORY 2STORY &UHNIR MWNRY WAU @ GOGE 11/01/2023 FIX 040 If RM 10112, FWBMEORCNRM MMMORCMURO UK MMwMRnwj4#4C0Prr0N L —1-or L GM 1--�4@ am FEM,(LIA 2STORY FMWFRM 2STORY E DWR FECESSED SILL 11101/2023 FZ 060 wMaym 4- z z DDIRPROPM 110FERM PRIINPERSPIMCM DDIA11,11511O 00011WENU 3. 111111110 FNIMPSM RUM wim ff$CK -11 IWI 1 5 ERM60M 4� -1 0" 1 "4& IMMAND0011 T. RUSHMIN13M 2STORY 2 STORY 2STORY IQW 2/28/2022 FIZ�70 81OWNSWRIFER lawwams AISMMMOSPLIX � 11111111FIG AIRE WXF. WAIDEOTNEWFINS ONOBARWLAPRUE4LMESW MMICLISORM"SEGINK WINAWALL01111.1.11a WITATOW"TOMMY0 SMAS0011r.Rem WKWIA PERM "Off.ON ow FMM UNWOMMINAMIX CK"FORM 7 FW am Wma NW110FOMBONVISIOU k MMPAMFLI OFOW.5110 WiL- wMemX0111101! T- SIAPER FLM �OFWNIIFM 01111111" 111=81AIMM881IO11111113MILY y9mumfil LAP SPLICE FLIN "NALMLON -%AiMON 110111-4 PER PLAN &--\THICKENED SW @ [ff. WAU @EMING) 11/0112023 MENGE @ SMEENED IN ENCLOSURES 11101/2023 RELINFNEMENT @ FM. CORNM 11/0112. L ---T F��100 Fl��720 It VAL& amnW03"Momillf RG 21111INEWALLWTVILPLATI� 0A FERPLAII ("0011T. 30PERPLA4 0110MURV. am WENAPERM -ARLOWPON 8 F08 THICKENED SLM @ WAGE NON BEMIN9 11/01/2023 NO;TO SCALE FZ--GW I! T rVAYIN.W.PBFUN OWSAPSIPUN MWRNII P)#4N3FDRMWWCCW.TYP. SEE FOUNDATION PLAN SEE FOUNDATION PLAN 9'/4' WROM F111111.11111111210-1200 WGINE PBEMMFFE LOVE ASOMM 1111MLOW011 -- --------------- ------------ � AWMPFE' I'VOSEW MNE&- 1,111611M WEVIN 111111111WRaPERM ROT 1011WWRIOLPER RM -MY1MM1IFW 13 — NO PENETPATION - CMU 11/12/2021 RECESS IN SW @ SHOW 2/28/2022 �Z'260 FMM-130 KL�/..�TOSCAUE WILLIRD 2~1111111101`18LLPLAT14 MMOOL130RVMSEMM FMFLM WMPLM JIM _j vm I i "Wolff. wcw. owAI Emw 2STORY -%ALMON F .q� THICKENED RM @ GARAGE @EARING) 11/01/2023 NO� TO SCALE FM­GZ0;;90 Fieldstone C.O.A.# ARCHITECURE-- AA26002802 <-- C.O.E.# ENGINEERING: 29349 13 IBRAHEM ELAYEil�,— P.E.# 91476 0 BENJAMIN NIESE, PE P.E.# 86025 05/30/2024 DATE W , 'i E w- Michigan 3400 Auburn Rd Suite 200 Auburn Hills, Ml 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FIL 33637 +1 813.466.3310 www.fieldstoneae.com z 0 > LU 0 C-1 Ell) U C, LU V� C<C < 0 -N L WN BY: FAE No. 860 VERSION: 5.0 SHEET # S1.0 AL 111110 7 25 SH wt LINTEL RECESS 2868 DOOR POUR SOUD I I I LINTEL RECESS OPT. 3068 DOOR I DIOTRA SAB 18F�16-OB]NlT WAUNTELRECESS 6-0811T� FLINE OF FLOOR ABOVE CONTINUOUS LINTEL OVER MASONRY COLUMN. DRILL 3' HOLE IN BOTTOM OF LINTEL AND EXTEND VERTICAL REBAR THROUGH LINTEL. 25 SH 25 SH LINE OF FLOO LINE OF FLOOR ABOVE ------- -11;� --------- POUR SOLID POUR 16070 OHGD FIRST FLOOR WALLMEADER PLAN - ELEV. "J" SCALE: 1/4'=1'4r NOTES: 1. REFER TO DWG SO. 1 FOR GENERAL STRUCTURAL NOTES 4000 Fi 0 C.O.A.# ARCHITECURE: AA26002802 ---- C.O.E.# ENGfiiiiiT�—� 29349 13 IBRAHEM ELAYE P.E.# 91476 E BENJAMIN NIESE, PE P.E.# 86025 05/30/2024 DATE UNTEL AND BOND BEAM LEGEND WM. LKrH3V1rNAQFM8PMWWTPMI?,f%U8E PFEMEM SMIX)ML111111ILMNITWMEAMB11111112OWCOALL I.WWWORGIBIS TMORNWO F-fLWW1llQlI1ff1U-tWW QN1110FAIIIIIIIIIIINW111(11110F F B/ T L QJLV00Ff5WMaMP -110MEW NWKWW 15 �ATIGPWI 1-1/2"CLEAR Ow am 7-5/W A UAL C'NOMINAL HEIGHT o.8602 At; 0 I If 0 AL. 2 E & 2 g Michigan 3400 Auburn Rd Sufte 200 Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FIL 33637 +1 813.466.3310 www.fieldstoneae.com It 0 Z Z z > LU d C) Z ct) U ct) < a 0 N 0 F- L RAWN BY: I FAE �VERSION:55:0:] SHEET 1A11E FIRST FLOOR I I IHDR PLN SHEET# S2.1 J_ =4= OR GIRDER PER MANUF. META16 8 Iza 4 s a C) C1 THA422 OR HANGER THA42� OR HANGER PER MANUF. PER MANUF . CANTILEVER — (2) 2X4 BUILT UP COLUMN On GIRDER PER MANUF. OR GIRDER PER MANUF. 11 11 1] @ FLOOR TRUSS: Z, VERTICAL REQ. AT THIS LOCATION FOR 2nd FLOOR STRAPPING. DESIGN FOR A CONCENTRATED REVERSIBLE WIND LOAD OF 2.ODO LB FLOOR/LOW ROOF FRAMING PLAN ELEV. IIJII SCALE: 1/4'-1'4r NOTES: 1 REFE TO DWG SO.1 FOR GENERAL STRUCTURAL NOTES L REFER TO DETAILS ON DWG 94.1 FOR ROOF SHEATHING REQUIREMENTS (2) META16 -i (-N� —7��7 (2) MTS16 TO (2) 2X4 BUILT UP COLUM. DTT2Z @ BASE 01 COLUMN w (8) 1/4_xl_l /2"SDS & 1/2" ATA SET_XP EPDXIED TO TOP OF CMU WALL BELOW, MIN Ir EMBED (2) MTS16 FROM TRUSS TO (2) 2�4 BUILT UP COLUMN. DTT2Z Ca BASE OF COLUMN 1 (8) 114"xl-1/2'SDS SCREWS & 12 ATR ACROSS 1 -) FLOOR AND EPDXIED TO TOP OF CIVIL WALL .18'EMBEDMENT. (R� If 11 iz )z f!:� RN ki In ski ROOF FRAMING PLAN ELEV. "J" SCALE: 1/,r=l'-O' NOTES: 1. REFER TO DWG SOA FOR GENERAL STRUCTURAL NOTES 2. REFER TO DETAILS ON DWG $4.1 FOR ROOF SHEATHING REQUIREMENTS (2) MTS1 6 TO (2) 2X4 BUILT UP COLUM . DTT2Z (91 BASE OF COLUMN wt (8) 1/4*xl_l /2SDS & 1/2" ATR SET-XP EPDXIED TO TOP OF CIVIL WALL BELOW. MIN. W EMBED Fi tone C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERING!---- 29349 13 IBRAHEM ELAYEB, Pf— P.E.# 91476 BENJAMIN NIESE, PE P.E.# 86025 TRM NOMS UNLESS OTHERWISE NOTED ON PLANS: 1. ALL TRUSS STRAPS TO MASONRY ARE TO BEMETA16. 2. ALL TRUSS STRAPS TO WOOD TO BE SIMPSON H1 OA. WHEN INSTALLED ON EXTERIOR WALLS SHALL BE CONNECTED THROUGH EXTERIOR SHEATHING. (2) H2.SA TO BE USED TO MULTI -PLY TRUSS. (1) EACH SIDE .18d NAJLS MIN. SIMPSON H2.5A MAY BE USED ON JACK TRUSSES ON THE EXTERIOR OF THE WALL W/8d MIN. 3. ILO TYP METAL TRUSS CONNECTORS, FRAME SCREWS MAY BE USED AT CONTRACTOR OPTION PER THE FOLLOWING: A) TRUSS TO TOP PLATE TO BE (2) SIMPSON SDWC15600 B) MULTI -PLY TRUSS REQUIRE (2) SDWC15MATEA * PLY C) (1) SDWC156DO SCREW FROM TOP PLATES To JACK TRUSSES 4. FOR DBIL TV41ST STRAP TRUSS CONNECTIONS (LTS/MTSfHTS) REFER TO DETAIL R60 FOR INSTALLATION CONFIGURATIONS. DISUMER FOR PLANS FIELDSTONE AE IS NOT CONTRACTED TO PERFORM TRUSS REVIEW ON , THE CONTRACTOR IS RESPONSIBLE TO ASSURE THE DIRECT COMPLIANCE OF TRUSS MANUFACTURER LAYOUT TO THESE DRAWINGS & VERIFY ALL TRUSS CONNECTORS ARE SUFFICIENT TO WITHSTAND THE UPLIFULATERAL LOADS IMPOSED. IF ANY TRUSS CONNECTOR SHOWN IN THESE DRAWINGS CAPACITY HAS BEEN EXCEEDED, THE TRUSS THE ENGINEER OF RECORD IMMEDIATELY E 2 2 6 15-5 x—f ..E2 z Z c Michigan 3400 Auburn Rd Suite 2GO Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae.com 't W) Z > w C) 04 2 cc U I Cn =i < R Cn 0 F_ _1 L _j DRAWN BY: I FAE No. 8 VERSION: 570 SHEETNAME 40 FLOOR/LOW W ROOF FRM PLN SHEET # 05/30/2024 DATE STRUCTURAL SHEATHING SEE PLAN AND DETAILS FOR Aii7A�HMENT PRE-ENGINEEREO 11/7 WOOD TRUSSES 1Z AT 24"O.C. MAX. HM ' EW -OR 2x RI 2x BLOCKING AT ATTAC BBON BOARD S SHEATHING EDGES �j (3)HED TO TRUSS ./M 1 Dd NAILS, 24' 8d NAILS INTO TRUSS D.C. CENTER MAX. S CONTINUOUS SPACING RAL STRUCTURAL SHEATHING CONTINUOUS STRUCTURAL AL NAIL PER TYPICAL SHEATHING NAIL PER S HEATHING DETAIL TYPICAL SHEATHING DETAIL TYPICALTRUSS ANCHOR PER PLAN TYPICAL TRUSS I DETAIL AT TRUSS HEEL - =9114. ANCHOR PER PLAN Nam REFFR TO ARCHITECTURAL DRAWINGS AND/OR TRUSS MANUFACTURER DRAWINGS FO SPECIFIC TRUSS PROFILE INFORMATION. (i.e. HEEL HEIGHTS, SLOPE, OVERHANGS) STRUCTURAL SHEATHING, SEE PLAN AND DETAILS FOR ATTACHMENT PRE-ENGINEERED WOOD TRUSSES AT 24"O.C. MAX. TRUSS ANCHOR PER PLAN FASCIA, (SEE ARCH DWGS) BONDBEAM PER PLAN DETAIL AT TYPICAL TRUSS w/ HEEL � 9 11,V NFE F)NR" TRUSS ON MASONfff 11/01/2023 O'� TO SCALE RZZIO IrmsEtTualgwat 1010SET OLO'LONOMORRAT RM@W= oww"* NOT"FERPLIVI 00111111OPEARM no BKMLM IMT08071128 :: wa w1oarTuirrowix ffAWPIRPIM ------------- V P AMM@EkVALOR%KMOMM assliplaiumas WMGMOFUMMMIMM R"4019AIM1.1118,0A ��) TRUSS VALLEY SET OVER FRAME 1110112023 RI NOT TO SCALE RWG-060 MIUMI&HR M10AIRnam mmim SMUCMSBMMERMMD �FMVMTMFM "WRIM-7 OMFOR 11011 Emu WOOD TROM.ATOf WX -OR- Or glum=igawfAmiNn villed h�MATUDBM1=li M.N.FOIW (JINK&Ifoitaruffirra OEM ­K FERIYPEALKAMMUL OMMINOKIMEATMHNOPWKL FRIOUPERPUN PER PLM FamKKOKEOERMNO DEVUR)RAT11011111" FRE womiumomm wK 1011118111111011ORRERPLIN RIMPERFUIN R1111APEEAKNONEIR MMW=ffjrWOUOmML RE117YPEALIPIENTMOE[AL I OEXAT1TFM1FIA6WM<$W I TRUSS ON FRAMING PIEBMMMBAT2fQt 101OMPERFUIRIVID SOHMMMUE VIEVINIOURM O'COUVOILLSEERMFOORMEMN. VIETANATI1.001110 ISR07 WALL BRACING @ NON-BRG. EXT. WALL (NON -SHEAR) 11/01/2023 NO_� TO SCALE RX�70 T-U%H= YM 2 T-11111011K I= 1 3 WE — T own 4 BMW 01— R13 NOT ww I Off. w, Gw HP —a- ROOF NO" Mill WHIS1131110200 Orman 1 1 2 3 mom 711CIPIVINUEONEM" Rmumoamm M Not ror. ror, ON &IIrxw iLewpmwommm ON FIVELFED COZZ III= f Of. IIIEK WMPATEDMM 4'14'�jt�4'-14' 3' 3/4' 43/4' +/-1/411 R + +/- 1/4' 1/4' 20� 0'-25* ALLlNMMNE10KMMIDlHEIKrULEMMMOFURM 221 221/2* 1101111 MFLtLwu=KMFMiiiFMMPMk OPTIMAL OPTIMAL & MMTW&IWMWM�E(r.�MOMIOPUM 221/2' TRUSS OR It MMTM11UCMMFU7=MlDFPLREONMWTHEVAL TRUS R A—W OP'n RAFTER TRUSS OR RAFTER TRUSS OR RAFTER WC' — SRO Tl E.HANG PE AMMONWOOMILL1010FRArETOMOMMORMEN 30* M RA MMSMKUANIDULW�=MWMAtRF (2) SDWC 1556000 (2) SDWC15600 (2) SDWC156MOO IMTMRMWMFnIM701CFRATEWMMB SO C �ANG OV LAN 0"JOLOANDWILL7111110=11191811OP&MIR WC15W� PLAN OVERHANG OVERHANG OVERHANG OVERHANG OVERHANG PER PLANLf -PER PLAN PER PLAN PER PLAN PER PLAN I 1/2._1 3, 4. _I /2"A 3/4" 3/4r- I 1/t4'314'- 1 1 W4)"' 1/2�1' 1/2`11 1/2'-1/8"' 111-7/.' mmsmcmFBRMA DUL=tCMFDAMA DOUILEMOINIRRINITION11 omomomrommo MMMOETFUNIO) parumEwfflnq pswompm mommaswomoiapRa 141TALL1111INJUITOPPLATEMINNIVIVIRM 111111111111010713PIRME11M INMIROMTOPPLATE MOTRUTA9M IMAMWO TO DOUBLE TOP PLATE SCREW CONNECTIONS RWW-020 (2) 10d NXILS CONTINUOUS CONT 2X4 (MIN) UCT STRUCTURAL '�HEATX. PER PLAN SHEATHING, SEE PLAN FOR tH 1 2X4 OUTRIGGER AT 24' D.C. REDD AT ATTACHMENT I OVERHANGS GREATER THAN 15% 10d TOENAILST% (2) A35 Ca EA_ ATTACH To GABLE DROPPED TOP CHORD OUTRIGGER TO 8 O.0 S HORIZONTAL BRACE. .1 TYP TRUSS CONNECTOR PER PLAN TRUSS ./ (3) 1 Od TOP PLATE ONE EA_ SIDE ILS WALL FRAMING i J STRUCTURAL PER PLAN ALONG TOP PLATE SHEATHING PER PLAN DROPPED TOP GABLE w/ OLMRIGGERS WOOD 2X4 BLOCKING C& CONT. 2X4 (MIN.) / REDD AT 170 MPH OR GREATER EDGE NAIUNG SHEATHING EDGE (2) 10d NAILS rDR wl (2) 10d 0 EA. AN IN LIEU OF BLOCKING AND ENDTO ADJACENT 2X4 LADDER FRAMING AT EDGE NAILING SHOWN TRUSSWEB 24" D.C. REDD AT BLOCKING AS REQUIRED WITHIN THE GABLE, IT IS (OR BOTTOM OVERHANGS UP TO 15". FOR BRACING BY TRUSS ACCEPTABLE TO USE CHORDNAIUNG ATTACH TO TRUSS TOP MANUFACTURER. .EDGE NAIL SPACING TO PERMANENTTRUSS BOTTOM CHORD OF TRUSS ASSHOWN) CHORD / (2) flid NAILS TO TRANSFER LOAD. AT16'O_C. BRACING PER TRUSS 2)(4 BLOCKING C& GABLE TRUSS / t- . SEE REQUIRED MANUFACTURER 0 104. TOE -NAIL SHEATHING EDGE wl VERTICAL WEBS AS BRACING PER TRUSS MAX. SPACING. M UFACTURER (1) ADDITIONAL FLAT 2X4 EDGE NAILING -EA-END NOTED IN THE (i.e. BSCI REO`MTS) (T20)1A0DJ@ACENT STU E , WITH BLOCKING SHEATHING D FRAMING SHEET A -A E)(TENDING A MIN. OF (3) SPILICED SHEATHING TRUSS NOTES TRUSS BAYS PLACED 1 i i M i:F4ZI H-I+t BETWEEN PERMANENT (3) 1 Od NAILS C& (3) 10d NAI (P TRUSSBRACING EA. TRUS p"MnprpiAlEWICM%Xig.MMgMg@*r'DA (RESULTING IN 5-'O� MAX. `�R� - TRUSS C LS R77 NAIL BOTTOM CHORD _/ I OVERALL SPACING) OF GABLE TRUSS w, =103WPLWOM 12ftAT4'O.C. HORIZONTAL 2x 5 _S 7:J7� MASONRY BLOCKING BETWEEN FIRST 3 BAYS OF SEE=FOR FMWM M SEEPUINM 01111. FRAMING To E ATT T OF ALL PERMANENT BRACING IN. w/ 10d @ 4' D.C. GABLE END TRUSS BRACING DETAIL 111 23 ROU — NOT TO SCALE RWM-M STRUCTURAL "Imomm= SHEATHING PER PLAN FERRM CONT. 2X4 / (2) 12d NAILS SEE REOUIRED BRACING PER TRUSS MANUFACTURER *twumm" OUTER Off.21111*012dftll HIM (MAKKOW VALAMERRIA111169NOZIREM)IT W AT VARWMgMASONUOIU.ATEOATEkENDT401MI�MLSOMM I* I MWO OWA71RTW It, ATLWV M M'aar =0111911FOAViN11KNK&MMIANIOURIOMMIXIM mom 1. nOTCUMTOMtSEONEVALMM Wf�A! Or NEMMPLM LATVBMMMM"Ior4LIE14VAL'MOBLEOPWMfBCME3MM &NVBMCALSOVER"MW#UEONEVAt'NOMI)MAMMONALMWKWOB MWkffk&HMnMIlEROOMMOTHEWSEMMvifltMATEk OCNAMMONMMMMMWWARDUOBALSOFM=fflHN MMANDWOEMOMMEkL'BCWffHMtghAMOIEMMHSOROPE USPIMCDOEM FOIE-FORMM— WE IOL ALL'VRMMDUDWMV$13hiifOr WIDIUMMATTIOPM am I.LGMMEOFNBTHMMEPEA3=MMWAMORRWMnML TWAMM r F*BWEBBY=lR=924 LED(EVMALSOA-FMOMMUENOWUSORMa FERRM 0AwjL &RSWAM02n3AFEMRMIO%OFTDIXHMWDTKMBMTWVFF4MWEDOE =1111051puil Ife"SPUIN 1118INCEIR ROOFISHEAMTHING ATTACHMENT DIAGRAM SPIM 8WF WMMOFIMWHEFC; 11/01f2023 Rn11FffiFIM RWG-110 FFiWKUWMM --'\ DUTCH HIP TRUSS BRACING DETAIL @OSTON HIP) FIT 0 — - 11/01/2023 NOT TO SCALE RX-1 00 11/01/2023 RVW-;30 CONT. 2X4 W (2) 12d NAIL TYPMXOMIIMPERPLM STRUCTURTAL SHEATHING PER PLAN SEE REQUIRED BRACING PER TRUSS "7 a" MANUFACTURER U a'L'0wff.MZ(4M*0fftVwFA'U"' VAOMMONONSATMWK&MOATEkMvi 911=111111,91971"FRI'LM �ORIMWEL �FORFMOSUMMLN LBKRHMNBTBtTOWUSEMUAI!B= KTWIviudolrotpmmolwvi DEGOPBPLM plumm SEERMFIONJOBOINIENTM& ERCMDEqHK virweTnewwwwff 101111110 ( RO C STRUICTURAL GABLE END TRUSS DETAIL 11/01/2023 ��NO4-;..cOHEATHEDSTRUCTURALGABUE) RWG-093 CIRO Fieldstone 0 C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERINer' 29349 13 IBRAHEM ELAYEB, PE, P.E.# 91476 0 BENJAMIN NIESE, PE P.E.# 86025 05/3.0/2024 DATE p� E 0 E . 45 E Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FIL 33637 +1 813.466.3310 www.fieldstoneae.com 0 z Z M Z LU 00 U UJI co cc N 0 F_ -1 L _j DRAWN BY: I FAE No. 86 5.0] VERSION: SHEET NAME DETAILS - ROOF OF Z ol 0 111�. .. '+ SHEET # RIO S -77 At. 111111111 81WYMPER KM 1011.11191,131 RM EXTERIOR WALL SHEATHING mmwmwl fflasswin MD I rm WM mm W101110M Id I lot I IM NLSM "WEISMAN NM "MR001114611 NEIMM 8 — 19$ *-47 �--- MARIMING =01191UTMASWIMLOUTINI WWWALLSHEATHING *BMW= PMENWAM I I MWIM I SIM sm 7/111FININI rx 1ror, me= 19 8 111RIMPALSEMM 'V;7FILDWAKYVP. =WLBK PAIRSIMMIANG PLMOWKM q4.WjffiMW&SMwFWMWw w3rkpLyj w0law M wwaft sm 81W am <110111ill 4Fr no 5iawii IF W= 5FT ISQ1011IFEARM MIME ULTSWIN11) Wwxcut HDOW go IN 510im 41r UrMV#wIwA-Iff&IAWTffi IV CNWH In IfluvipliawkHIrlow1walm IV -- �MWN 5F — DTRZTI*~&MWTM Ir hMWMF8RN8= 117ALFEW111 POUIMOMFORLM pi! pial!i!ioil MUM S1D HEADER CONRGURATION WMFUMM aovmupjBMMUMlMHDSWLIEUMBFURAIROFSWMWBMLADWrMBM imrem MFDJGMML wwww4v 1WRIISMPFUMCOMEM WFLM FIXIMMUMMINOM MI MWIB6WW=WMF9tRAK WATRIMUMV. ATMMUMIRROUMPF wa 3TWMWwW3UPLY4 tummm Imm HININCLI11 am ow MW 5140im 4ff 1.1110 �14IWH OR mom 5< 110 IWWH Ur Illwa W&SUDWS Mwax rm IDEW 140WH 4Fr OwN w Lma on NMWL&* <OWN Sff WWLA 'APPLYMEWRIJUSUWHORMWAMMM was= ALT. HEADER CONFIGURATION awmanilwor.0awm 10FI11117=11MOMMMMPSWOUM. END SHEATHING DUAIL 11101/2023 BEARING Wa FAM �TMCAL SHEATHING MAIL 11/0112023 W02 TVIC& ORNING @ 1110112023 NO�TO SCALE 10 (��)NOT TO SCALE warom ZZ050 DMILEWUPRAIE N W51MUM16MME1013MAI 29FUIPMPIR MHMWOW. MMIMAPaRm 91 IN 2[WMRM MWWL Vw 9116, ?AW e�= �BEMNWI WALL W/o UPLIFT 11/01/2023 W�z 11 ROMPSIBIWAMMM XMILFORM WAOMMUM9WOM 01TRWITKI1111RAIE EMBIMMMMUM EDOEWIMIFffifMALMALL RATB offAMNMODWERMISSW RQF9tW,EDGEWLWPfflRM W M -us UNUMSEAMPERM 111TWE OKWUNIMMLOM. 0 LM RM WA_U�S�ECTIII AT STAIR OPENING 11/01/2023 W�Z 21 W.WUFOKM Bff.WLLMFLM Ptww"8V=TC RM x4aw"llwotwLWIEND INT. WALL CONNEMON M EXT. WALL WRINK WUMATTAOW UWFUIP.T.1111010WOM ban MUCHRKWWWWTKA11PROMOM UPTKU nirar,13VIIIIIIEFLATUDITWOURIKU ATBOUMFORM FAMNTIM 9MMIMMPOIRIMMONRM AL190 opkig NcKmmkm �T-WNMM<�W-IM FU li MAND7WffiW1IWVflIw EIIIIIEW P. B&M WNDMATTACHMEW DETAIL W14 (�)4 1110112023 NOT TO SCALE W=140 WOMROATUDIIII917 ITSM IIII(EWMIKUR)WOM UW0M hP.T.w RIOMMAIDIrUMMMI(lWaNWIT ATEODDORPOIRM FROUTAPPIDA a: AUMM UMMMFFRMM kKT0IRMWKMUWTK8@4'FR0MI3W HE ntratMERWOMMINUIM M" WWPfflRIWWWHffM F.FM awn DWR ATTACHMEW DUAIL STRICAL W15 11/0112023 I NO;70 SCALE WGM-150 KWUMBEROWN )FACEIMTOADAMUM MoRalwWAL slaomr.T.VMN i�l MWOMMAIII)MMUI(WIlf TIOLISOR 08111PUMMIT IMORARMOMI'MGM SUMSTWOMMInt wow ww"NIMUR awmDOORK17PACK MMOP91110114FAMM 110101111K 1108MEWWORWAMKI W..i WIN 11/01/2023 TYPICAL GARAGE DOOR ATTACHMENT W16 NO;;O SCALE W�;--160 MMFMRM #611IM11010WIR 05111111iltvOMMUD rivarigourgIURM 5ER1Xffi=FWnwM Z128/2022 TVICAL REINKIRCED RWED CELL DETAIL 11101/2023 - WGW-181 KLYINU� TO SCALE W�Zw SBMFBRM ammewout &MMKLELTOOMMIN WAL BDMWMRAYMV# 1111216WWAS91rot NSUMRATSTWTI 11"wKsetru a(mewot W18 1ACMER 7/1612021 NOT TO SCALE wa;180 CIM1111ft(lypjklaw OEMMMTEE FERARPEFIRM MINclk TYPICAL CMU IWERSECTION DErA1L 11101/2D23 \,,/NOT TO SCALE W��--182 TI)POMMATI117171110FTOP IRSTWOM SM ONMI dRMPLATE HEIGHT PER PLAN bav"Sw ...... "WRATKATELIE" RaffaLIMUMOM AUNMWAO EMDLWM &RUNDITISIGSWOPEKOW PERRM FRIDEM 1� //1P..E1.HTPERP1. WAMPERPLM ftKI84W0&,0RRAT2KKIG* DILORII'VADENTUM "Milm-KNOPM RMWDTB sulown 1101"Wa 011RU t: M&DINUORRATh Kma!r- 02KOILMM MUMwWwol —&KLRA1EV#V.LM*= ORM wwwMPfflRM ow #CFNU@Ek w SHEAR WALL 11/01/2023 12 W;Z-1 20 E .6'. a bgs H .6 12 I Michigan 3400 Aubum Rd Suite 200 Auburn Hills, Ml 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, Fl- 33637 +1 813.466.3310 www.fieldstoneae.com 0 Z 0 Z z > 0-4 w w 0 F- En 04 tr >' U < r C) ORO Fi eldstone C.O.A.# ARCHITECURE: 1. DRAWN BY 4 AA26002802 C.O.E.# ENGINEERING: No. 8 VERSION: 5.0 29349 = * : 13 IBRAHEM ELAYEB, PE SHEET NAME DETAILS P.E.# 91476 WALL N BENJAMIN NIESE, PE 3 IF SHEET # P.E.# 86025 05/30/2024 010 /// I i NAL S4.2 DATE 111111% bMEVALONFIE RWURAVOINP 811LUKIBTMIATUawpa KI(MMUK04 W RANWITMORMUM . =WW=WK018ff101&A!VUQMVi ftMEKLP0K^00wr.&Ka M M00=01M nNUMIRM FNRED(EMLE ROMMMIATMOWPERGEk 4 wo MaEDGEWN 4P 1118901FIRKM biWA=lf1.f#l1MfflwQ%dK88lD rclNuum"AWIT.W. QW&&PR=VMffAC1ffiV= SPIM MPOW wxwoit , OOR TRUSS TO MASONRY WALL TO —M—M 11101/202;3 aimeaRmwapowwP" sntL%w9Evlw1ATP0WFffi K310UwLLPjDPKw";i R^wU.1w=R0M*MMw- �9z/- UwKf8w&ATV0Ew ftFVAM1PERRAK0N.21KA7E*Q*MwwU3 F91PLM RMWAMIRK w4ammmm RMWPMKM ft"wTwPffiw" NST" mmaml— RXIMMOM M&BOWId"Otroz a�wafflKAW-hpmw"wu 01111cw�19=18116 NRMKM URWT#Xp Amm 1dw"rQtUL*wN MrAMONLIS Namwwm RNFIRRM MM16MMOU rONKLMIRIVEM18F. PERRM soms as RM L02 TRUSS TO MASONRY W&L 11/01/2023 NOT TO SCALE L;Zo ftPAE1KLFE1R^0ff.ft RAIENIffMIKSOVOt, M1fr,b1KWWKMVtW0d#ERMW FIRCMI&M&UPOWFER ITOEWLEDMrATRIS RAKOWMUDIROM00 fflw=K*DM&ATww 090031PERPIA PERPLM ROORSEUMIATMOW PIE am 9EMN PFE WTRUPEWMWIPMOR WMERPIRWW.UX DEKMPERPLM \� -NM RTR JOIST @ LOW ROOF 12/17/2021 &lf?RY CONNECTION AT BW L15 "\2-STOW NNE 8/18/2022 \__/NOT TO SCALE LGG-150 N SCf 61 hFW*VKLPl1K^0ff.&KM.(ffMMLS@V0t 0KCwffwM&flww 0EA1047MKIMMMME pmqm�w %S7ft70Ek7W UMUXA "M==M 10�111wu EaKew" MLOW"Nommuror, WREW.MPIM FLOOR TRUSS w/ CANTILEVER MERTM MOD (04111/2023) ��NO�TO SCALE LTw-0Z'(--010) ('� BEARING STUDS TO BOND M I MAKLPIRPIM WWA0000FIRRMIMMMUSOR ?wNMwwaMwww1M18NENw UM VMRMMFIM MWORMWORMAS M 6800814MMM M 0wftLwffM1wff.w.Pffi LM TAIL 2128/2022 Ll;�--260 mommmiraw PMPLM 21NAIGURRACOMOt RXIEWMadlKSOEATFUM 8=10101'DIRMFORLIKIR wa PERRAN RMSEAMUTDOW RR M WM1fPM=WrA90 lim2frATIMMYALM ORWAP10=11AIE 0wT.h4K0wAUMV1P)10dQrA8rw17Mwj8 TCEATKM MKI1118010 8RMwwM1ffww FMKM FIEBERM SE"wPaPA IMUMMOIRMNOUTDOWPOt lVAOITMOROMWO &PMKLP91P1^0ff-&Kw1f"K$ twor, R001190MIATMOMP11101KICS 1RAPSIPLM kPIMMUMPEN79MPER RM rCWWMrA1VW.0F. PRRM .Nn. MULL01 I NOMMA00MM10 MUL off.agum""OpedilrA =V0Ew=TDUTRZ 9MMKINUTM&ATUOM PIRPLM 70POMEMPFE was PERME'STWP81pun jQ2dL�WWx9&63MM 1ATwV9=AMBw= kqomororl BEARING WALL @ RDORIROOF TRUSS 2/2812022 - FLOOR TO MASONRY Wa @ LOW M 2/28/2022 &1�2�N �,�140� TO SCALE LGG-M 0; TO SCALE �;M-120 COO Fi 0 C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERING: 29349 13 IBRAHEM ELAYEB, PE P.E.# 91476 0 BENJAMIN NIESE, PE P.E.# 86025 05/30/2024 DATE lid 41t* E 0. 025 OF oe ....... A xxx 111111% O's 8 '62 r p, E 22 Michigan 3400 Auburn Rd Suite 200 Auburn Hills, Ml 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae.com C �z z < > -:l < w C� Lu Ld 0 C/) 0 < U C6 LU V) < 11 DRAWN BY: I FAE I I �VERSIOM �5.O 1 SHEET NAME DETAILS FLOOR SHEET # S4-3- Ic �t MNPMLE 1 2'1 K It IMFORWINIMBRA -IL- - 101891 1 I/Z WL KIKKFACIUMME WILEPUMPERMA www1m W15IWWAVCE�LVWTWffiW WKIII08111 33 ow.NEM930mn mwwmmm�vmwmn IMAIMMOTHK 3/4'- 1 1/4' Italia E6108MVIlKsm 11138109MIMMKIM &,TOPQFWALL ' 'ORB f�— FIRKMOMMM FORMLISIOMIM , '--M"MEzj RM wommPoirm '-p HRM 1111011KII011113EM PIEDWEEFBWRM F*eoEmWTNM IMMTMMFOILON smamsKUPERrm �O�TYPICAL STAIR DETAILS 11/1212021 I'm APKTWNW S, ANKTWSM N(�T TO SCALE ZG-101 PIURRM4 (ORMFERWA WAWIM TMNWFB I"llwPat 8=11EM IMMEW 1111 I/V V 1111 it jULK).U11(1 1)1w)1wwNTW- At�fflampw KKMFBWogrioopa u� 1-1W am. -���F FLOOR ROMM FAMPERCIANIMPM 0311IMPM am& Farm MBEENIFOIRM Maim immTRX11111MINEUM 1,111IFFIIIIIINIF. FERFLN 11110911100111M. 1.108FINPOEAffm POW1.1011 MWROWINFIXEIAL MID FERRM 01TIMMIlow. mm woolworAmmm MMI#PWM MW SLLPERPLM PRIUDERJ &OFAM 06W.0 TYPICAL STAIR DEWLS 2J28/2022 ALLWAR S10 103 \_,J�T �PF 11U UMFUOR UIERIOR ING INTERIOR NUFAMPLM INTERIOR Q- SE111M.0w AnKA NMRA .107M MINNOW WFWMMMOWOrMMIFUM d-,WFKFL MFKFL 1111160 ALUI9 Ea EV ma Maim 811111111F1 UC$rW#rA$MWM KIIIJIMMINUISFINI WiKTDI.WWXOWwwmffwnmmw 1101CMIKINSFIXI WKWN&W.Rat 10M DMOR lfwadermwWwwwr MWWAIN WKNK&MWFK M28mg� W29MOMM 7TPII�Ckk 1 STORY WALL SECTION 711612021 TYPICAL I STORY WAU SECTION 7116/2021 E��AL STAIR DETAILS 11/12/2021 ws�zlo wz�-020 wzr,05 NEOZ.FMALOOFFM SEMMMAISFOR VWTW f,0'-0'FIN.FL. FORINIKUMINIFFM TYPICAL 2 STORY WALL SECTIN 11/01/2023 ��O� TO SCALE VWG-Mi Fiel&tone C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERI�� 29349 13 IBRAHEM ELAYEB, PE P.E.# 91476 0 BENJAMIN NIESE, PE P.E.# 86025 05/30/2024 DATE 10 r. 5 Z V . ��E - ' E 5 E —0. Michigan 3400 Auburn Rd Suite 200 Auburn Hills, M1 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, Fl- 33637 +1813.466.3310 www.fieldstoneae.com It 4 z Z z < > J N�-o w L'U C) UIr LU V) Cn 0 < C 04 E-1 F -I L -i PrDRAWN BY: I FAE Z�- Nlioi.- 8602 VERSION: 5.0 SHEET NAME DETAILS - FLOOR STATE SHEET # .. ........ NA1. S4-3-1 PRECAST LINTEL GRAVITY LOAD TABLE v4.22 LOADS LISTED RAVE SEEN CALCULATED OR CID WILED FROM APPROVED MANUFACTURERS CAST-CRETE, LOTTS CONCRETE, QUALITY PRECAST CO. MAXIMUM LOAD (PLF) APPROX. LINTELLENGTH MAX.CUEAR OPENING TYPEA S'UNTtL 8' TYPE B rTYPEC 12' TYPE 6 22'11YPEC 14' TYPE 8- l4wTYPEC- 16' TYPE B 16-TYPEC 20' TYPE 3 W-TYPEC 24' TYPE B 24-TYPEC 28' TYPE B 2rTYPEC BY TYPE 9 32-TV"C z 10, r 61 223'. 3069 3729 328C 5163 66C7 8C54 95C2 3059 4605 5206 6113 7547 8974 loom IOODD 3' 1' Z 2' 223. 3069 37.9 318C 5163 65C7 BC54 95cz i DOCC 30159 4605 5206 6113 7547 8974 IDOOD 100DO Al' 01 28, 1783 2561 2751 32W 382C 489, , 596- 7034 0�07 2561 4505 520' 5205 6113_ 7547 8974 10" 10000 4-6" 12' 1343 2'1C 2992 291 3756 4576 54C., 6224 1969 4375 OS 5206 6113 7019 0672 10000 !DODO TV '438 1716 LU6 -.999 256C 3-32 3166 4249 1349 31"D R4567 5355 4766 5817 7074 8203 1-4- 4! 0" rM7 '349 1439 1999 256C 3-32 3686 4649 1349 3090 4567 5365 4766 5817 7074 8203 via, CIS" we -IC5 '1-73 E. ! 60C 1631 2C9C 2549 3-C9 347C IlDS 2622 4242 4360 3942 1 4989 5817 6662 1. li� 51 2" 710 '232 2� 077 3738 348C 3C3. 37C7 4383 5C6. i232 .77 27. 3. 13111 .60 8625 7590 r6" 6 2" 570 _ 99 1 1729 2108 263' 2,2C5 2698 3-91 36M 991 1729 2 10B _ 263�__ 31198 5661 4742 55M V4" 7101 488 699 1-6C '.5.6 -626 2564 3486 2818 33C2 699 1245 1516 1193 2564 3486 2964 3397 V 4� V 011 416 699 -6c N,A 2564 346 28.8 33C2 699 1245 N/A 1943 2564 3486 2964 3397 20, S' BY 2' 354 535 89, 1 WA -2.7 1 DOS 3 2777 2.63 2536 535 1054 N/A 1533 2D93 2781 2259 2615 315 567 891; N/A -366 184f 2423 3-27 41C* 567 945 NIA 1366 111 2423 3127 40M IVY' ICY all 292 525 673 N/A 1254 1684 2.93 28C5 3552 525 $73 N/A 1254 1584 2193 2805 3552 12'T 1112, Z77 471 55 AMI/A LIG75 1428 L838 2�, 28W 472 755 N/A 1075 1428 1838 2316 28821 13',r: Iz 01 255 471 755 N/A 1 1075 '.428 1 .838 23-6 2535 1 471 755 N A 1075 2428 1838 2316 29M 14'(r Iz a" 239 424 206 N,'A 1002 326 .697 2.27 2278 424 706 N/A 1002 1328 1697 2127 2630 1418, 131 NIA N/A N,'A 1 WA N,,A N/A NI N �'A N/A -N/A 783* IN A 1231 1421v 1779* 21W 2662' 15, Ir 14! G' N/A N,A NiA N/A_ N/A N� �A N/A N/A NiA N/A 710' N/A 111510- 1331- 16450. 2D32a 2459- 17"r 16 0' N/A WA N,A N, A N/ N,A N/A N,A NIA N/A 5'* N/A 952* 1117' 1379' 1671- 1997' 191 Isro' - NUA WA N/A N/A N;A N/A N/A N/A N/A N/A 75D* qw. 1177- 1415' 1675- 2D'O' it fr' NIA N"A WA N;'A N/A N/A N, A WA NIA N.-A 340' N/A 598' 845* 1114' 1345' 1469' 24'T 2Z 111' N/A N'� N, A N N'A N,';, N"A N, A WA NIA M' 650* .8w 1090- 1220- I-PRESTRESSED Ir W/2" RECESS U-UNTE�5 Type A= Unfilled no Reber; Type 8= Continuous Gou:, Steel perPlan in Bond Beam Only; Type C = Conunous Gmu-,Szeel per plan In Bond Beam L Lintel LEGEND * 8x8 FILLED CELL W1 (1) #5 REBAR BEAMS 8X8 FILLED CELL W/ (1) #7 REBAR HEADER - WIDTH TO MATCH WALL GIRDERS 8X8 FILLED CELL W/ NO REBAR REOD - - - ------ PLUMBING WALLS (FOR REFERENCE) ----------- BEARING/SHEAR WALLS (FOR REFERENCE) 45' CMU - FILL CELLS W/ #5 REBAR ROOF BLOCKING 2X12 FILLED CELL W/ #4 REBAR (11N WALL) BALLOON FRAMED 2X12 FILLED CELL W/ #4 REBAR WALLSIHIGHER BEARING WALLS (11N COLUMN) CONCRETE TIE BEAMS lv� ELEVATION INDICATOR PLUMBING PENETRATION FOR DETAIL INDICATOR FRAMING LAYOUT LINTEL OR WOOD HDR DESIGNATION OPEN SIZE (ALL WOOD HDR'S TO BE (2) PLY U.N.O.) 0- BRACED WALL UNE FASTENERS ALLOWABLE LOADS CONNECTOR CITY I TYPE JUPLIFF 110 1.0 Obs) 0 16 (LATER R.) @ 1.6 META16 a 0.14rxl-1/2- 11:140 F2 : 770 HETAIS 9 0.14111"11 11110 Fl: 360 f2 770 f2) METAIG * I -ON 10 0.14ra-1/2" 1875 Fl. 680 F2 770 (2) META16 62-3-.1. 14 0.162*.3-1/2' 1795 FI 1285 r F2: 1. (2) HETAIG @ 1-PIM 10 I 0.148-xl-1/2' 1920 FI 690 F2 770 (2) HETA16 0 2- or 31 12 0.162'K3-1/2" 2365 FI: 1350 F2 � 1430 H 116 S'rN_ 8 0.148'.1-1/2' 1110 FI: 120 F2: 90 4 114"Al-314- CONC SCREW LGLINVII-2 6 3/8' '�L E-4 TEN '- .250 2-5 6 4-. 2 1/� .7��CL REW MSTC28 36 0. 148P x 3 1/4" 3460 MTS12 14 0.148"xl-1/2' 990 - (21 MTS12 28 0.1411'xI-Inp im - MTS16 1 14 1 0.148-al-in. 990 HU210.2 2 /4" x 2 t� SCREW 3SOO law 10 3 WS16 32 0.148'.1-212" - 2.890 (ZINTS16 16 0.1411"ll-W" - 1310 FITS20 24 0.1""XI-In' 1310 LSTA12_ 10 0.1411".2-ln" 925 LSTA18 14 0.148-M2-1/2' 1235 LSTA30 22 0.148'x2-1/2" 164D MSTA24 is 0. 148' X 2 1/2" 1,640 (2) MSTA24 36 0. 148- X 2 112' 3.2110 MSTA,36 26 0. 148' X 2 1/2' 2ASO (21MSTA36 1 52 0, 148' X 2 112- 41DO MSTA30 22 0.148".2-In" 2060 MSTC20 36 0.148'. 3 1/4' 3,400 IVII 62 0.148"K3-1/4" 4735 MSTAM24 9 0 148" X 3" 1.425 5 i7�- X 2 1/4- MSTAM36 13 0.148"X 3" 1.870 11 IJ4' X 2 1/4' (2) MSTAM36 26 16 0.148 " 3" w xi!�74- 3740 MSTCMNMo 10 1/4"x2-1/4"CONC SCREW 2. 14 0.148"x3-114" MGT 22 0.148".3' 3965 Fl 775 F2: 52S I 5t8'ATR HGT-3 16 C.lT8-.3' 10.790 2 314'ATR V6TR or L 5/8'ATR 2225 FI: 6�0 F2 630 16 1/4"x3- SOS VGTRjL 2 9362 S/2'ATR 55,45 FI: 650 F2 630 32 1/4-x3- SDS VGT SA!"ATIR 4940 Fl � 1105 F2: SW 16 1/4-xEl� SDS (2) VGr 2 5/8"ATR 17185-2pty @ago- 3.1,M F1 1185 F2 590 1/4.3" SDS DTT2Z 1 8 1/2' ATR 114"WSIDS 1825-20 ml. 21454212*4min - HTT4 I 5/8-ATR 3610 is 0. 14M'x3- In' HTTS I 4670 26 MiAT 7;_ BI HTT5ICr 1 5"S -M n��12- ABU44Z 1 5/11- ATIR 7570 1900 12 0.162-a3-1/2- ABU66Z 1 5/8- ATIR 18205 247S 12 0.162"x3-1/2" H2.SA 10 0.131".2-W" - 565 FI 110 F2: 110 H 10A is 0.148"xl-1/2' - 1340 Fl . 565 F2 285 HIOA-2 It 0.1411"xl-112" 1000 F1 6210 F2 260 HUC48 14 1/4"M2-3/4" CON� SCREW 3500 1135 6 0.1411'x3 HUC414 24 114".2-SCREW - -1-1 12 M?Ii� LUS26 4 0,148"X3' 865 1265 SF414 12 0.1481 side 640 Cefflv: 1290 OTC clip, 4 31 CONC SCREW. -- - Fl: IS F2: 135 2 0.131".2-1/2' A35 12 - FI 650 F2 6 704 SDWC15600 I SDWC1560D 615 F1 130 F2 225 SDAVC15450 I SDWC15450 295 F2: ISO HTU26 20 0.162".3-1/2" 3200 1250 14 0.148'.3" LGU3.63-SDS 1� � � 6,720 53SS 12 �4' 4- X 2 4DU8-SDS2.S 7,870 TIO �A '27105 HDUIll-SDS2.S 1 1' ATR - 11.17S 30 1/4 - X 2 112- SDS THD26 20 0.162'. 3" 2- 3240 20 0. 148' x 11/2" FT-7- 2 28 ' 4310 4060 1 16 _0.162"!3 0.148' x 3. ABBREVIATIONS: AB ANCHOR BOLT EA EACH INT INTERIOR AFF ABOVE FINISHED FLOOR ELEV ELEVATION JST JOIST ALT ALTERNATE EMBED EMBEDMENT MAX MAXIMUM APPROX APPROXIMATE EN EDGE NAILING MFR MANUFACTURER ARCH ARCHITECT/ARCHITECTURAL ED EQUAL MIN MINIMUM ATR ALL THREADED ROD ES EACH SIDE MISC MISCELLANEOUS BLK BLOCK EW EACH WAY MO MASONRY OPENING BUKG BLOCKING EXP EXPANSION NOM NOMINAL BOF BOTTOM OF FOOTING EXT EXTERIOR NTS NOT TO SCALE BOT BOTTOM FD FLOOR DRAIN CDC ON CENTER BRIG BEARING FDN FOUNDATION OPNG OPENING B1WN BETWEEN FIN FINISH OPP OPPOSITE CANT CANTILEVER FLR FLOOR PEN PLYWOOD EDGE NAILING CL CENTERLINE FINI FIELD NAILING PLYWD PLYWOOD CIP CAST IN PLACE FT FOOT / FEET REINF REINFORCINGIREINFORCEMENT Ci CONTROLJOINT GAL-V GALVANIZED REOD REQUIRED CLR CLEAR GDR GIRDER RO ROUGH OPENING CMU CONCRETE MASONRY UNIT GIRD GRADE SC STUD COLUMN COL COLUMN GWB GYPSUM WALL BOARD SHTG SHEATHING CONIC CONCRETE GYP GYPSUM Sim SIMILAR CONT CONTINUOUS HD HOLD DOWN SP SOUTHERN PINE #2 OR BETTER DBIL DOUBLE HDR HEADER SPIF SPRUCE PIR FIR #142 OR BETTER DIA DIAMETER ILO IN LIEU OF TYP TYPICAL I DWG DRAWING IIN INCH IUNO UNLESS NOTED OTHERWISE 140 WINDSPEED CHARTS 140 MPH 2023 FIL - C & C Pressures (ASCII Efted[w Wind A- Gable Roof Components I HIPIU,.1' mp-, W.11C.Impnent, zone I 2_ Z27 3_49 Z- 1 1 Zone 2 Zone 4 A� 100 SQFT(Grde,$) 1 3 je 17.1 42.7 1 17.1 0 14.8 -30.3 1 14S -36.5 14 8-13 36,5 31.1 1 -34.1 A. 50 SOFT IMAM n do- 1 .4 1 19.2 1 -54.9 1 &7 -36.0 1 18U7 -32.7 1 18.7 419 - - 327 7 -359 1 32 -7 1 -413 A� ]LOSCIFr(Fas-en- 4.2 1 -83LI 1 24�2 1 -96.6 2T� -49.0 1 11 1 11 1 1 11 3 11 5 - 1 -19.7 1 365 1 -49.0 Componentsarld Cladding Preswires(ASID) - 2023 FL Positive Neeadve Width Height Effect- Pressure PresIaire D2Kd2dM Z= 1111 iftj Area Ift2l Lofl LRS91 16070 OHM --- 16 7 112 30.8 1 -34,4 3069 w/3010 TR ENDS 3 a 24,0 34.6 -45,1 3D68 w/3010 TR 4 3 a 29LO 34.6 -37.7 309D DOOR ENDS 3 a 24,0 34.6 -453 25SH 4 3 5.25 15.8 35.6 -311.7 SON SM 4 6 6.67 40.0 1 314 -36.6 28M DOOR 4 Z67 6.67 27.8 35.3 -31111.3 305M 4 3 5 15.0 35.7 -38.8 305DSH INDS 35.7 -47 3 204M ENDS 2 4 1LO 3&S -4 0 6011110 SGD 4 6 8 48LO 32.8 -3ro DESIGN PRESSURES SHOW ARE MINIMUM ALLOWABLE VALUE& VALUES ARE TO BE INCREASED AS REQUIRED BY MORE STRNGENT LOCAL REQUIREMENTS ORD Fieldstone 0 C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERING: 29349 0 IBRAHEM ELAYEB, PE P.E.# 91476 N BENJAMIN NIESE, PE P.E.# 86025 05/30/2024 DATE 10 No. 86025--,/,.,-/" -P, STATE oil E 2 E 1,1 a r Michigan 3400 Auburn Rd Suite 2DO Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae.com 't C z LD zM Z § ci w 'W c Cn 04 LD cuci >� Cn 0 C<C D4 < o 96 W 0 F- -1 ,ERAWNBY-F FAE VERSIO SHEET NAME REFERENCE CHARTS SHEET # S5011