Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Daerr Ridge St (3)
mm W1 IV MiTek' RE: TTH126-132 MiTek USA, Inc. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Site Information: Customer: Starligght Homes Project Name: TTH126-132 Lot/Block: 126-T32 Model: 7 Plex Address: . Subdivision: Tyson City: Zephyrhills State: Florida General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.6 Wind Code: ASCE 7-16 Wind Speed: 150 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 32 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date No. Seal# Truss Name Date 1 T30641470 C 1 A 5/25/2023 21 T30641490 T11 5/25/2023 2 T30641471 C3A 5/25/2023 22 T30641491 Vol 5/25/2023 3 T30641472 CJ 1 5/25/2023 23 T30641492 V02 5/25/2023 4 T30641473 CJ3 5/25/2023 24 T30641493 V03 5/25/2023 5 T30641474 EJ5 5/25/2023 25 T30641494 VO4 5/25/2023 6 T30641475 HJ5 5/25/2023 26 T30641495 V05 5/25/2023 7 T30641476 T01 5/25/2023 27 T30641496 V06 5/25/2023 8 T30641477 T02 5/25/2023 28 T30641497 V07 5/25/2023 9 T30641478 T03 5/25/2023 29 T30641498 V08 5/25/2023 10 T30641479 T04 5/25/2023 30 T30641499 V09 5/25/2023 11 T30641480 T04A 5/25/2023 31 T30641500 V10 5/25/2023 12 T30641481 T05 5/25/2023 32 T30641501 V11 5/25/2023 13 T30641482 T05A 5/25/2023 14 T30641483 T06 5/25/2023 15 T30641484 T06A 5/25/2023 16 T30641485 T07 5/25/2023 17 T30641486 T07A 5/25/2023 18 T30641487 T09 5/25/2023 19 T30641488 T10 5/25/2023 20 T30641489 T10A 5/25/2023 This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision %%01 11 t r lli l l,,��� based on the parameters provided by Builders FirstSource - Plant City. % op�CLOIN VF�� Truss Design Engineer's Name: Velez, Joaquin�..���C E N My license renewal date for the state of Florida is February 28, 2025. Florida COA: 6634 No 68182 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. �-33 ' STATE OF .' 41/ . .0R� Cam. 1111111100 Joaquin Velez PE No.68182 3lrrek Inc. DHA MiTek USA FL Cert 6634 16023 Swingle, Ridge Rd. Chesterfield, NIO 63017Dow May 25, 2023 1 of 1 Velez, Joaquin Job Truss Truss Type Qty Ply T30641470 TTH126-132 C1A Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:21:58 2023 Page 1 I D: tP uYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?P sB7OHg3N Sg Pqn L8w3u ITXbGK WrCDoi7J 4zJC?f -1-0-0 1-7-10 Scale = 1:9.0 2x4 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020rrP12014 CSI. TC 0.12 BC 0.03 WB 0.00 Matrix-P DEFL. in (loc) I/deft L/d Vert(LL) -0.00 2 >999 240 Vert(CT) -0.00 2 >999 180 Horz(CT) -0.00 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 7 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-7-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=82(LC 12) Max Uplift 3=-26(LC 9), 2=-122(LC 12) Max Grav 3=31(LC 17), 2=132(LC 1), 4=32(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=oft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 26 lb uplift at joint 3 and 122 lb uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code" This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagrde Velez PE \0.68182 NETek 1u, DBA 1JITek USA FL Ce (6634 16023 SRiag ty Ridge Rd. C'h-(.11reld, MO 63017 Date: May 25,2023 WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSVTP/i Quality Criteria, DSB-89 and BCSi Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway. Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641471 TTH126-132 C3A Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:21:59 2023 Page 1 ID: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PSB7OH g3NSgPgnL8w3u ITXbGKWrC Doi7J4zJC?f Q93-3-10 ' 3-3-10 1 2x4 = 3-3-10 M ro Scale = 1:13.2 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) -0.01 2-4 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.11 Vert(CT) -0.01 2-4 >999 180 BOLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BO,DL 10.0 Code FBC2020rrPI2014 Matrix-P Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-3-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=126(LC 12) Max Uplift 3=-80(LC 12), 2=138(LC 12) Max Grav 3=81(LC 17), 2=188(LC 1), 4=62(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown NOTES- (7) 1) Wind: ASCE 7-16; Vuit=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-2-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rein loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3 and 138 lb uplift at joint 2. 7) ,'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jongnln Velez PE No.68182 .LDTek lac. DBA YBTek CSA FL C'ert 4634 16023 SMoglec Ridge Rd. Ckeslerrteld. MO 63017 Due: May 25,2023 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYMI Quality Crkerls, DSB-89 and BCS/ Building Component 16023 Swingley Ridge Rd Saferylnformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply T30641472 TTH126-132 CJ1 Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 2x4 = 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:21:59 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 1-4-14 1-4-14 Scale = 1:7.4 1-4-14 1-4-14 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.12 Vert(LL) -0.00 2 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 2 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 6 lb FT = 20% LUMBER- BRACING - TOW CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-4-14 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=65(LC 12) Max Uplift 3=-17(LC 9), 2=129(LC 12) Max Grav 3=19(LC 17), 2=127(LC 1), 4=27(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 17 lb uplift at joint 3 and 129 lb uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Iongaiu Velez PE N-68182 \Blek luc. DBA I�BTek USA FL Cert 6634 1602.1 Swingles Ridge Rd. Chesterfield. N10 63017 Date: May 25,2023 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is far an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTekn is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUM1 Quality Cdterla, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Sa"Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641473 TTH126-132 CJ3 Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:00 2023 Page 1 1 D: tPuYCeVfQTfYt30C?ZvfnpzlG U H-RfC?P sB7OH q3 N Sg P qn L8w3u lTXbG KWrC Doi7J4zJ C?f -1-0-0 3-9-11 1-0-0 3-9-11 2x4 = Scale = 1:12.4 3-9-11 3-9-11 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.35 Vert(LL) -0.01 2-4 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.15 Vert(CT) -0.02 2-4 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-P Weight: 14 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-11 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=119(LC 12) Max Uplift 3=-87(LC 12), 2=153(LC 12) Max Grav 3=87(LC 1), 2=205(LC 1), 4=72(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-8-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 87 lb uplift at joint 3 and 153 lb uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joognin Velez PE No.68182 WTek luc. DBA JBTek USA FL Cert 6634 16023 SwIngley Ridge Rd. Chesterfield. N10 63017 Date: May 25,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building tlesign. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYMI Quality Criteria, DSB-89 and BCS/ Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641474 TTH126-132 EJ5 Jack -Open 34 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 2411:22:01 2023 Page 1 I D: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3NSgP gnL8w3u ITXbGKWrC Doi7J4zJ C?f -1-0-0 5-0-0 1-0-0 5-0-0 3x4 = 5-0-0 ro ui N Scale = 1:17.4 Plate Offsets (X Y)-- [2:0-4-0,0-0-31 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) -0.03 2-4 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.28 Vert(CT) -0.06 2-4 >909 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 18 lb FT = 20% LU BER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=173(LC 12) Max Uplift 3=-137(LC 12), 2=155(LC 12) Max Grav 3=134(LC 17), 2=247(LC 1), 4=96(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vu@=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces 8r MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) rovide mechanical connection (by others) of truss to bearing plate capable of withstanding 137 lb uplift at joint 3 and 155 lb uplift at roint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any This item has been particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagrda Yelez PE \o.691a2 AtTek Iae. DBA 4BTek USA FL Cen 6624 t6023 Sniaglec Ridge Rd. Chesterfield, 170 63017 Date: May 25,2023 A WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSkTIPI1 quality Cdteds, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641475 TTH126-132 HJ5 Diagonal Hip Girder 4 1 Jab Reference (optional) nuuaers rITSI00urCe 1 I amps, ruj, I amps, rC - 33004, 3x4 = 8.1530 S NOV 19 2022 MI I eK Industries, Inc. Wed May 24 11:22:01 2023 Page 1 I D: tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?P sB70Hg3N Sg PgnL8w3u ITXbGK WrC Doi7J4zJC?f 7-8-13 Scale = 1:17.2 7-8-13 7-8-6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) 0.15 2-4 >603 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.33 2-4 >276 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20201TPI2014 Matrix-SH Weight: 26 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-4-9, 4=Mechanical Max Horz 2=172(LC 8) Max Uplift 3=-180(LC 8), 2=-283(LC 8) Max Grav 3=183(LC 1), 2=388(LC 1), 4=148(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9) 1) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=3011; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 180 lb uplift at joint 3 and 283 lb uplift at joint 2. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 104 lb down and 23 lb up at 1-6-10, 85 Ib down and 34 lb up at 2-6-11, and 47 lb down and 106 lb up at 4-8-1, and 108 Ib down and 95 lb up at 5-1-14 on top chord, and 5 lb down at 1-6-10, 8 lb down at 2-6-11, and 27 lb down at 4-8-1, and 23 lb down at 5-1-14 on bottom chord. The This item has been design/selection of such connection device(s) is the responsibility of others. electronically signed and 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 'This Sealed by Velez, Joaquin, PE 9) manufactured product is designed as an individual building component. The suitability and use of this component for any building building using a Digital Signature. particular is the responsibility of the designer per ANSI TPI 1 as referenced by the building code." Printed copies of this LOAD CASE(S) Standard document are not considered 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 signed and sealed and the Uniform Loads =- Vert: 1-3=-54, 2-4=20 signature must be verified Concentrated Loads (lb) on any electronic copies. Vert: 7=-3(F) 8=-2(B) 11=-5(F) 12=5(B) J..gNa V.I.. PE Na.68182 Ntiek Luc. DBA hDTek USA FL Cert6634 16023 Swingley Ridge Rd. Chearecl710d, 3i0 63017 Dare: May 25,2023 WARNING - Vedy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641476 TTH126-132 T01 Hip Girder 2 Job Reference (optional) 6unaers rimiooUrce t I ampa, r-L), I ampa, rL - SSbb4, d.oSU s IN v 1 `J zuzz MI I eK meUSrrles, Inc. vvea May Z4 11:zz:Ub zuz3 rage 1 ID: tPuYCeVfQTfYt30C?ZvfnpzlG U H-RfC?PsB7OHg3NSgP gnL8w3u ITXbGK WrC Doi7J4zJ C?f -O-Q 6-2E 11 4-12 16-5 6 21-6-0 26-6-10 31-7-4 36-9-10 43-0-0 Q4-0-0 i-0-d 1--216 5-2 6 5 0 10 510-10 5-0-10 5-0-10 5-N 6-2-6 -0 5.00 12 6x8 = 2x4 II 3 21 22 4 23 4x8 = 7x8 = 4x8 = 24 5 2526 27 6 28 2930 7 31 2x4 11 6x8 = 32 8 33 34 9 Scale = 1:73.6 5x8 = 20 35 36 19 37 38 1817 39 40 16 41 42 1514 43 44 13 45 46 12 5x8 = 2x4 11 5x8 = 7x8 WB = 4x8 = 2x4 11 5x8 = 2x4 11 2x4 I 7x8 WB = ii 36-9-10 43-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2020ITP12014 CSI. TC 0.57 BC 0.35 WB 0.72 Matrix-SH DEFL. in Vert(LL) 0.82 Vert(CT) -0.96 Horz(CT) 0.13 (loc) I/deft Ud 16 >625 240 16 >534 180 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 531 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 `Except` TOP CHORD Structural wood sheathing directly applied or 4-4-13 oc purlins. 3-6,6-9: 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 8-1-10 oc bracing. BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-94(LC 6) Max Uplift 2=1645(LC 8). 10=1722(LC 8) Max Grav 2=2532(LC 1),10=2602(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5972/3778, 3-4=-8812/5811, 4-5=-8810/5809, 5-6=-11509/7662, 6-7=-11509/7662, 7-8=-8924/5934, 8-9=8926/5936, 9-10=-6152/3976 BOTCHORD 2-20=-3371/5458, 19-20=-3370/5475, 17-19=-7061/10896, 16-17=7061/10896, 15-16=-7123/10952, 13-15=-7123/10952, 12-13=3553/5641, 10-12=3554/5625 WEBS 3-20=0/450, 3-19=2515/3773, 4-19=495/505, 5-19=2340/1584, 5-17=0/383, 5-16=-539/717, 6-16=-447/498, 7-16=-454/644, 7-15=0/383, 7-13=-2267/1515, 8-13=-495/505, 9-13=-2451/3705, 9-12=0/449 NOTES- (11) 1) 2-ply truss to be connected together with 1 Od (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. This Item has been Webs connected as follows: 2x4 - 1 row at 0-M oc. electronically signed and 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to sealed by Velez, Joaquin, PE ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. using a Digital Signature. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vuk=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. Printed copies of this 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber document are not considered DOL=1.60 plate grip DOL=1.60 signed and sealed and the 5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific signature must be verified to the use of this truss component. 6) Provide adequate drainage to prevent water ponding. On any electronic copies. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. lo,grda vel- PE 1e.69182 8) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Wiek Inc. DBA 3B2ek USA FL C'en 6634 will fit between the bottom chord and any other members. 16021 Swingley Ridge Rd. ckearer6ew, afo u3o17 9 Provide mechanical connection b others of truss to bearing late capable of withstanding 1645 lb uplift at joint 2 and 1722 lb uplift (Y ) 9 P P 9 P 1 P Dare: at joint 10. May 25,2023 A WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. . Design valid for use only with Mirek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYMI Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Intonation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641476 TTH126-132 T01 Hip Girder 2 Job Reference (optional) twilaers t- rstSource (I ampa, FL), I ampa, FL - 33b64, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:06 2023 Page 2 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB70Hg3NSgPgnL8w3ulTXbGKVVrCDoi7J4zJC?f NOTES- (11) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 158 lb up at 6-2-6, 125 lb down and 153 lb up at 8-3-2, 125 lb down and 153 lb up at 10-3-2, 124 lb down and 153 lb up at 12-3-2, 124 lb down and 153 lb up at 14-3-2, 124 lb down and 153 lb up at 16-3-2, 124 lb down and 153 lb up at 18-3-2, 124 lb down and 153 lb up at 20-3-2, 124 lb down and 153 lb up at 21-6-0, 124 lb down and 153 lb up at 22-8-14, 124 lb down and 153 lb up at 24-8-14, 124 lb down and 153 lb up at 26-8-14, 124 lb down and 153 lb up at 28-8-14, 124 lb down and 153 lb up at 30-8-14, 125 Ib down and 153 lb up at 32-8-14, and 125 lb down and 153 lb up at 34-8-14, and 225 lb down and 372 lb up at 36-9-10 on top chord, and 141 lb down at 6-2-6, 56 lb down at 8-3-2. 56 lb down at 10-3-2, 56 lb down at 12-3-2, 56 lb down at 14-3-2, 56 lb down at 16-3-2, 56 lb down at 18-3-2, 56 lb down at 20-3-2, 56 lb down at 21-6-0, 56 lb down at 22-8-14, 56 lb down at 24-8-14, 56 lb down at 26-8-14, 56 lb down at 28-8-14, 56 lb down at 30-8-14, 56 lb down at 32-8-14, and 56 lb down at 34-8-14, and 141 lb down at 36-8-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code" LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=54, 3-9=54, 9-11=54, 2-10=20 Concentrated Loads (lb) Vert: 3=-68(B) 9=-167(B) 20=-88(B) 5=68(B) 17=-28(B) 16=-28(B) 6=-68(B) 15=-28(B) 7=-68(B) 12=-88(B) 21=-68(B) 22=-68(B) 23=68(B) 24=-68(8) 25=-68(B) 27=-68(B) 28=-68(B) 30=68(B) 31=-68(B) 32=-68(B) 33=-68(B) 34=68(B) 35=-28(B) 36=-28(B) 37=-28(B) 38=28(B) 39=28(B) 40=-28(B) 41=-28(B) 42=-28(B) 43=28(B) 44=28(B) 45=28(B) 46=28(B) A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not . a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent budding of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTR1 Qua/Hy C~a, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Type Qty Ply F T30641477 TTH126-132 T02 2 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MTek Industries, Inc. Wed May 2411:22:07 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -�1-0-Q 5-1-7 8-7-3 15-1-10 21-6-0 27-10-6 34-4-13 37-10-9 43-0-0 4,4-0-p i-0-d 5-1-7 3 5 12 6-6-7 1-41 64-6 61i 7 3-5-12 + 5-1-7 -0 Scale = 1:73.6 3x4 = Sx6 = 5.00 12 3x4 = 4x6 — 3x4 = 5x6 = 4 21 522 23 6 7 24 825 26 9 A 2 Io 5x8 = 18 17 16 15 14 13 5x8 = 4x8 = 6x8 = 4x4 = 4x4 = 6x8 = 4x8 = 8-7-3 17-7-10 254-6 34-4-13 43-0-0 8-7-3 9-0-7 7-8-12 9-0-7 8-7-3 Plate Offsets (X,Y)— [2:0-4-0,Edgel, [4:0-3-0,0-2-41, [7:0-3-0,Edgel, [9:0-3-0,0-2-41, [11:0-4-0,Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) 0.63 15-16 >811 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.87 15-16 >591 180 BCLL 0.0 Rep Stress Incr YES WB 0.47 Horz(CT) 0.18 11 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 239 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-6-14 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 5-18, 8-13 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=-127(LC 10) Max Uplift 2=-943(LC 12). 11=-943(LC 12) Max Grav 2=1642(LC 1), 11=1642(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3606/2164, 3-4=-3350/1984, 4-5=-3101/1890, 5-6=-4582/2725, 6-8=-4582/2725, 8-9=-3101/1890, 9-10=-3350/1984, 10-11=-3606/2164 BOT CHORD 2-18=-1889/3276, 16-18=-2429/4354, 15-16=-2620/4761, 13-15=2412/4354, 11-13=-1906/3276 WEBS 3-18=-266/323, 4-18=-519/1010, 5-18=-1504/893, 5-16=-140/447, 6-16=-291/242, 6-15=-291/242, 8-15=-140/447, 8-113=1504/893, 9-13=-519/1010, 10-13=266/323 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 8-7-3, Exterior(2R) 8-7-3 to 14-8-3, Interior(1) 14-8-3 to 34-4-13, Exterior(2R) 34-4-13 to 40-5-12, Interior(1) 40-5-12 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck electronically signed and to the use of this truss component. sealed by Velez, Joaquin, PE 4) Provide adequate drainage to prevent water ponding. 5) This has for bottom using a Digital Signature. truss been designed a 10.0 psf chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Printed copies of this will fit between the bottom chord and any other members. document are not Considered 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at signed and sealed and the joint 11. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any signature must be verified particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." on any electronic copies. Joagnta Velez PE N..69182 \IiTek rue. DH 14DTek USA f1 Cen 6634 16023 Sviugley Ridge ad. Chesterfield, MO 63017 Date: May 25,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M17EK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M [Tek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP/1 Quality Criteria, DSB-88 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641478 TTH126-132 T03 Hip 2 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:08 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3uITXbGKWrCDoi7J4zJC?f 71-0-Q 6-0.5 11-0A 18-0-9 24-11-7 32-0-0 36-5-11 43-0-0 q4-0-p -0- 6.6-5 4-5-11 7-0-9 6-10-13 7-0-9 4-5-11 6-6-5 -0- 5x8 = 2x4 11 5.00 12 421 22 5 23 5x8 = 24 6 25 5x6 = 726 Scale = 1:73.7 4 0 Ie 0 3x6 � 18 17 16 15 14 13 12 11 3x6 2x4 11 3x4 = US = 3x10 = 2x4 11 5x6 = 3x8 = 2x4 11 6 6-5 11-0-0 18-0-9 24 -1 % 32-0-0 36 5-11 43-0-0 6-6 5 4-5-11 7 0 9 6-10-13 7-0-9 4-5-11 68.5 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020lrP12014 CSI. DEFL. in (loc) I/deft L/d TC 0.87 Vert(LL) 0.52 14-15 >988 240 BC 0.94 Vert(CT) -0.73 14-15 >699 180 WB 0.75 Horz(CT) 0.23 9 n/a n/a Matrix-SH PLATES GRIP MT20 244/190 Weight: 218 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except` TOP CHORD Structural wood sheathing directly applied. 4-6: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 6-15, 6-12 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 9=0-3-8 Max Horz 2=159(LC 11) Max Uplift 2=-943(LC 12), 9=-943(LC 12) Max Grav 2=1642(LC 1), 9=1642(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3513/2077, 3-4=-3065/1877, 4-5=3608/2259, 5-6=-3608/2259, 6-7=-2810/1792, 7-8=-3066/1877, 8-9=-3512/2077 BOT CHORD 2-18=-1794/3166, 17-18=-1794/3166, 15-17=-1479/2792, 14-15=-1949/3605, 12-14=-1949/3603, 11-12=-1806/3165, 9-11=-1806/3165 WEBS 3.17=-476/379, 4-17=-161/394, 4-15=577/1078, 5-15=398/374, 6-14=0/281, 6-12=-1058/570, 7-12=-462/882, 8-12=-475/379 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 11-0-0, Exterior(2R) 11-0-0 to 17-1-0, Interior(1) 17-1-0 to 32-0-0, Exterior(2R) 32-0-0 to 38-1-0, Interior(1) 38-1-0 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate This item has been grip DOL=1.60 electronically signed and 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck sealed by Velez, Joaquin, PE to the use of this truss component. using a Digital Signature. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Printed copies of this 6) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide document are not considered will fit between the bottom chord and any other members. signed and sealed and the 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at signature must be verified joint 9. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any on any electronic copies. particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." JoagWn Velez PE \u.69182 MiTek Inc. DBA \llTek USA FL Cert 6634 16023 Swiagley Ridge Rd. Ch-terecm.310 63017 Date: May 25,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI7 quality Cmerla, DSB-89 and BCS/ Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job T uss Truss Type Qty Ply T30641479 TTH126-132 T04 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:10 2023 Page 1 ID: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC? P sB7OH q3N Sg PgnL8w3u ITXbGKWrCDoi7J4zJ C?f -�1-0-p 7-0-5 13-4-13 18-9-10 24-2-6 2:941 35-11-11 43-0-0 q4-0-p -0- 7-0-5 6-0-8 5-4-13 5-4-13 5-4-13 6-4-8 7-0-5 -0- 5x6 = cnnF;-�— 3x4 = 5 20 3x4 = 3x6 = 6 7 5x6 = 8 Scale = 1,73.9 3x8 = 18 17 1O ZZ 4. 1. 4w c. iv 13 12 3x8 = 2x4 II 3x8 = 4x6 3x4 = 4x6 = 3x8 = 2x4 11 7-0-5 13-4-13 21.6-0 29-7-3 35-11-11 43-0-0 7-0-5 6-4.8 8-1-3 8-1-3 6-4-8 7-0-5 Plate Offsets (X,Y)—[2:0-4-2,0-1-8),[4:0-3-0,0-2-41,[8:0-3-0,0-2-4),[10:0-4-2,0-1-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.82 Vert(LL) -0.41 15-17 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.80 Vert(CT) -0.71 15-17 >724 180 BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(CT) 0.21 10 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 219 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-6-12 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-191(LC 10) Max Uplift 2=-943(LC 12), 10=-943(LC 12) Max Grav 2=1861(LC 17), 10=1861(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3963/2094, 3-4=-3216/1782, 4-5=2947/1724, 5-7=3388/1933, 7-8=2947/1720, 8-9=-3216/1778,9-10=-3964/2090 BOT CHORD 2-18=-1811/3722, 17-18=-1811/3722, 15-17=-1592/3365, 13-15=-1587/3312, 12-13=-1819/3579, 10-12=1819/3579 WEBS 3-18=0/276, 3-17=784/507, 4-17=-405/963, 5-17=-654/357, 5-15=0/254, 7-15=0/254, 7-13=-654/360, 8-13=-406/963, 9-13=-785/507, 9-12=0/276 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 13-4-13, Exterior(2R) 13-4-13 to 19-5-12, Interior(1) 19-5-12 to 29-7-3, Exterior(2R) 29-7-3 to 35-11-11, Interior(1) 35-11-11 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 10. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagale Velez PE 110.69132 MiTek Inc. DBA VBTek t SA FL Ceti 66.14 1602..1 Swisgley Ridge Rd. Che,l-field, MO 63017 Date: May 25,2023 a WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek- is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVM1 Quality Criteria, DS849 and BCS/ Building Component 16023 Swingley Ridge Rd Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641480 TTH126-132 T04A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:11 2023 Page 1 I D: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC? P sB7OH g3NSgPgn L8w3u ITXbGKWrC Doi7J4zJC?f -,1-0-Q 7-0-5 13- 13 18-9-10 24-2-6 29-7-3 35-11-11 43-0-0 7-0-5 6-4-8 5-4-13 5-0-13 5-0-13 6-4-8 7-11 5x6 = s nn171-7 3x4 = 19 5 20 3x4 = 3x6 = 5x6 = 6 7 8 Scale = 1:73.8 3x8 = 17 16 10 ZZ 143 14 144 ZD 13 12 11 3x8 = 2x4 II 7-0-5 13-4-13 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 10=0-3-8, 2=0-3-8 Max Horz 2=190(LC 11) Max Uplift 10=-857(LC 12), 2=-944(LC 12) Max Grav 10=1807(LC 18). 2=1861(LC 17) 3x8 = 4x6 21-6-0 3x4 = 4x6 = 3x8 = 2x4 II 29-7-3 35-11-11 , CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TIC 0.85 Vert(LL) -0.41 12-14 >999 240 MT20 244/190 BC 0.80 Vert(CT) -0.71 12-14 >723 180 WB 0.77 Horz(CT) 0.21 10 n/a n/a Matrix-SH Weight: 217 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-4-7 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3964/2102, 3-4=-3217/1790, 4-5=2948/1731, 5-7=-3390/1945, 7-8=2951/1723, 8-9=-3220/1794, 9-10=3964/2100 BOT CHORD 2-17=-1855/3714, 16-17=-1855/3714, 14-16=-1622/3358, 12-14=1637/3305, 11-12=-1846/3592, '10-11=1846/3592 WEBS 3-17=0/276, 3-16=-784/507, 4-16=-405/964, 5-16=-655/358, 5-14=0/255, 7-14=0/253, 7-12=-654/357, 8-12=-416/965, 9-12=793/515, 9-11=0/277 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 13-4-13, Exterior(2R) 13-4-13 to 19-5-12, Interior(1) 19-5-12 to 29-7-3, Exterior(2R) 29-7-3 to 35-11-11, Interior(1) 35-11-11 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-D-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 857 lb uplift at joint 10 and 944 lb uplift at joint 2. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." I6 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jaagala Velez PE No.68182 1711e1k Ise. DBA NUTek USA FL Cer i 6634 1602.1 Swlagley Ridge Rd. Ckesierffeld. MO 63017 Date: May 25,2023 0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev, 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not . a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall _ building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and pemranent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSUMI Quality Comria, DSB-89 and BCS/ Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641481 TTH126-132 T05 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:12 2023 Page 1 1 D:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?P sB7OH q3N Sg PgnL8w3u ITXbGKWrC Doi7J4zJC?f -1-0-Q 15-9-10 21-6-0 27-2-6 34-7-12 43-0-0 -0-(1 8 4 4 7-5-5 5 8E 5-8-6 7-5 5 4p 8-44 d 5.00 F12 5x8 = 2x4 II 5x8 = 5 18 6 1920 21 7 Scale = 1:75.2 3x8 = 16 15 Cd 14 w 13 12 3x8 = 2x4 II 5x6 = 3x8 = 5x6 = 34-7-12 2x4 II LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TP12014 CSI. TC 0.97 BC 0.88 WB 0.36 Matrix-SH DEFL. in (loc) Udell Ud Vert(LL) 0.36 14 >999 240 Vert(CT) -0.56 14-15 >920 180 Horz(CT) 0.20 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 222 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 "Except' TOP CHORD Structural wood sheathing directly applied. 1-4,8-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-6-5 oc bracing. BOT CHORD 2x4 SP No.1 'Except' WEBS 1 Row at midpt 3-15, 9-13 13-15: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-223(LC 10) Max Uplift 2=-943(LC 12), 10=943(LC 12) Max Grav 2=1861(LC 17), 10=1861(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3888/2047, 3-5=-2973/1686, 5-6=2882/1743, 6-7=2882/1743, 7-9=2973/1686, 9-10=-3889/2047 BOT CHORD 2-16=-1752/3670, 15-16=-1752/3670, 14-15=-1217/2786, 13-14=-1230/2675, 12-13=-1766/3503, 10-12=1766/3503 WEBS 3-16=0/345, 3-15=980/593, 5-15=210/669, 5-14=-198/447, 6-14=-337/305, 7-14=-198/447, 7-13=-210/670, 9-13=981/593, 9-12=0/345 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) 15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 44-0-0 zone; cantilever left and This item has been right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 electronically signed and plate grip DOL=1.60 sealed by Velez, Joaquin, PE 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck using a Digital Signature. to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. Printed copies Of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. document are not Considered 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-&0 tall by 2-0-0 wide signed and sealed and the will fit between the bottom chord and any other members, with BCDL = 10.Opsf. signature must be verified 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 10. on any electronic copies. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any Joagrdn VA- PE N..69132 particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." NBTek I— DBA 3BTek USA FIL Ccri 6634 16023 Swiaglep Ridge Rd. Ck-1-fiield. \f0 63017 Date: May 25,2023 WARNING - Venty design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUMI Quality C~&, DSB-89 and BCS/ Building Component 16023 Swingley Ridge Rd Satety/Mormallon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641482 TTH126-132 T05A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:13 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -�1-0-Q 8-4-4 15-9-10 21-6-0 27-2-6 34-7-12 43-0-0 8.4.4 7-5-5 5-&S 548-6 7-5-5 8-4-4 Scale = 1,75.1 5.00 F12 5x8 = 2x4 11 5x8 = 5 17 6 18 19 20 7 3x8 = 15 14 — 13 — 12 11 3x8 = 2x4 II 5x6 = 3x8 = 5x6 = 2x4 11 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TP12014 CSI. TC 1.00 BC 0.90 WB 0.36 Matrix-SH DEFL. in (loc) I/deft Ud Vert(LL) 0.36 13 >999 240 Vert(CT) -0.56 12-13 >918 180 Horz(CT) 0.20 10 n/a file PLATES GRIP MT20 2441190 Weight: 220 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. 1-4,8-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-4-12 oc bracing. BOT CHORD 2x4 SP No.1 'Except* WEBS 1 Row at midpt 3-14, 9-12 12-14: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=221(LC 11) Max Uplift 2=-944(LC 12), 10=-857(LC 12) Max Grav 2=1861(LC 17), 10=1807(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3889/2054, 3-5=-2974/1694, 5-6=2884/1753, 6-7=-2884/1753, 7-9=2975/1694, 9-10=-3884/2055 BOT CHORD 2-15=-1797/3663, 14-15=1797/3663. 13-14=-1261/2779, 12-13=1249/2675, 11-12=-1791/3514, 10-11=-1791/3514 WEBS 3-15=0/345, 3-14=980/593, 5-14=209/669, 5-13=-1991448, 6-13=-337/306, 7-13=-196/447, 7-12=-212/672, 9-12=989/600, 9-11=0/346 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vu1t=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) 15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Extedor(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 42-10-4 zone; cantilever left and This item has been right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 electronically signed and plate grip DOL=1.60 sealed by Velez, Joaquin, PE 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific using a Digital Signature. to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. Printed copies Of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. document are not Considered 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide signed and sealed and the will fit between the bottom chord and any other members, with BCDL = IO.Opsf. signature nature must be verified 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at joint 10. on any electronic copies. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any JoagNe Velez PE N..68182 particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Mlrek l— DBA NDrek USA FL Cen 6634 16023 Swngley Ridge Rd. Chesterfreid. MO 63017 Date: May 25,2023 0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev 5/192020 BEFORE USE. Design valid for use only with MfrekO connectors. This design is based only upon parameters shown, and is for an individual building component, not , a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PIi Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Sarety IMormadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oily Ply T30641483 TTH126-132 T06 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:14 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 18-2-6 24-9-10 30-7-13 36-6-0 43-0-0 4p-0-0 1-0 0 6 6 0 5-10-3 5-10-3 6-7-3 5-10-3 5-10-3 616 5.00 12 5x6 = 6 20 5x8 = 721 Scale = 1:75.2 3x8 = „' "' 11 .r 16 11 15 - `o 41 10 3x8 = 3x4 = 4x6 = 3x8 = 3x4 = 4x6 3x4 = Plate Offsets (X,Y)—[2:0-4-2,0-1-81,[6:0-3-0,0-2-41,[7:0-5-12,0-2-81,[11:0-4-2,0-1-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.84 Vert(LL) -0.40 13-15 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.70 13-15 >733 180 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(CT) 0.20 11 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 223 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.1 'Except' BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except: 14-17: 2x4 SP No.2 5-8-0 oc bracing: 15-16. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-16 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=254(1-C 10) Max Uplift 2=-943(LC 12), 11=943(LC 12) Max Grav 2=1872(LC 17), 11=1876(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3934/2082, 3-5=-3693/1963, 5-6=2723/1603, 6-7=2481/1552, 7-8=2733/1603, 8-1 0=-3702/1963, 10-11 =-3943/2082 BOT CHORD 2-18=-1800/3760, 16-18=-1470/3172, 15-16=-1093/2484, 13-15=1483/3010, 11-13=1813/3578 WEBS 3-18=-333/332, 5-18=-192/687, 5-16=820/522, 6-16=-296/753, 7-15=-297/836, 8-15=-820/522, 8-13=-192/687, 10-13=333/332 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuk=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 18-2-6, Exterior(2R) 18-2-6 to 24-3-6, Interior(1) 24-3-6 to 24-9-10, Exterior(2R) 24-9-10 to 30-7-13, Interior(1) 30-7-13 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 This item has been plate grip DOL=1.60 electronically signed and 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck sealed by Velez, Joaquin, PE to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. using a Digital Signature. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Printed Copies of this 6)" This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide document are not considered will fit between the bottom chord and any other members, with BCDL = 10.Opsf. signed and sealed and the 7) id' mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at signature must be verified joint 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any on any electronic copies. particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." J..gala bete. PE 1ce.69182 .101e1k roc. DBA VD7ek USA FL Cem 6634 160LI Swiegley Ridge Rd. Cae.terfield, MO 63017 D.re: May 25,2023 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing T ek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Mi I fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVM1 Quality Cdferra, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Sarety IMonnadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641484 TTH126-132 T06A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:15 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB70Hg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -�1-0-p 6-6-0 12-4-3 18-2-6 24-9-10 30-7-13 36-6-0 43-0-0 -0-5-10-3 5-10-3 6-7-3 5-10-3 5-10-3 60 Sx6 = 5.00 12 6 19 5x8 = 720 Scale = 1,75.1 3x8 = .r — co 1O 15 w 14 'o co 1. is 3x8 3x4 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCOL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 'Except" 13-16: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=253(LC 11) Max Uplift 2=-944(LC 12), 11=-857(LC 12) Max Grav 2=1873(LC 17), 11=1822(LC 18) 4x6 = 3x8 = 3x4 = 4x6 = 3x4 = CSI. DEFL. in floc) I/deft Ud PLATES GRIP TC 0.87 Vert(LL) -0.4012-14 >999 240 MT20 244/190 BC 0.98 Vert(CT) -0.70 12-14 >734 180 WB 0.99 Horz(CT) 0.20 11 n/a n/a Matrix-SH Weight: 221 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except: 5-7-5 oc bracing: 14-15. WEBS 1 Row at midpt 7-15 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3935/2089, 3-5=-3693/1971, 5-6=2725/1611, 6-7=2483/1560, 7-8=-2734/1605, 8-10=-3710/1974, 10-11=-3954/2108 BOT CHORD 2-17=-1844/3753, 15-17=-1514/3165, 14-15=-1112/2483, 12-14=1504/3011, 11-12=-1842/3589 WEBS 3-17=-333/332, 5-17=-192/687, 5-15=820/522, 6-15=-297/754, 7-14=-298/837, 8-14=-823/525, 8-12=-217/693, 10-12=338/353 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 18-2-6, Exterior(2R) 18-2-6 to 24-3-6, Interior(1) 24-3-6 to 24-9-10, Exterior(2R) 24-9-10 to 30-7-13, Interior(1) 30-7-13 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at joint 11. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code" This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagnlo Velez PE la.69182 NlaTek lac. DRA NIITek USA FL Cert 6634 16023 Svviagley Ridge Rd. Chesterfield, N10 63017 Dete: May 25,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rP/f Quelky Criteria, DSBAg and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Qty PlyT30641485 TTriussType TTH126-132 T07 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:16 2023 Page 1 I D: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3NSgP gnL8w3u ITXbGK WrC Doi7J4zJC?f 1 0 Q 7-0 1 13-0-0 19 1 8 21101 30-0-0 3111-15 43-0-0 44-0-0 1-0 0 7-0-1 5-11-1� 6-1-8 4-9-0 6-1-8 5-11-15 7-01 0. 5x6 = 5.00 12 5x8 = Scale = 1:75.2 3x8 = io I. « it 16 1. 15 iv cr ca io 3x8 = 3x4 = 5x6 WB = 3x8 = 3x4 = 5x6 WB 3x4 = A c6 [o LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 * BCDL 10.0 SPACING- 2-0.0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TP12014 CSI. TC 0.73 BC 0.96 WB 0.41 Matrix-SH DEFL. in (loc) Vdefl Ud Vert(LL) -0.40 13-15 >999 240 Vert(CT) -0.70 13-15 >728 180 Horz(CT) 0.17 11 n/a n/a PLATES GRIP MT20 244/190 Weight: 228 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-3-0 oc purlins. 1-4,9-12: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP 2850F 2.0E or 2x4 SP M 31 *Except* WEBS 1 Row at midpt 5-16, 7-16, 8-15 14-17: 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=267(LC 11) Max Uplift 2=-943(LC 12), 11=943(LC 12) Max Grav 2=1871(LC 17), 11=1873(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3899/2048, 3-5=3656/1936, 5-6=2628/1546, 6-7=2388/1500, 7-8=2631/1546, 8-10=-3661/1936, 10-11=-3905/2048 BOT CHORD 2-18=-1764/3735, 16-18=-1422/3112, 15-16=-1019/2395, 13-15=1434/2951, 11-13=-1776/3539 WEBS 3-18=-351/346, 5-18=-214/750, 5-16=877/557, 6-16=-330/762, 7-15=-326/836, 8-15=-879/558, 8-13=-214/751, 10-13=351/346 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuk=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 19-1-8, Exterior(2E) This item has been 19-1-8 to 23-10-8, Exterior(2R) 23-10-8 to 30-0-0, Interior(1) 30-0-0 to 44-0-0 zone; cantilever left and right exposed ; end vertical left electronically signed and and right exposed;C-C for members and forces s MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 sealed by Velez, Joaquin, PE 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific using a Digital Signature. to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. Printed copies Of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. document are not Considered 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide signed and sealed and the will fit between the bottom chord and any other members, with BCDL = IO.Opsf. signature nature must be verified 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 11. on any electronic Copies. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any JoagaW VA.. PE N..68182 particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Mirek Iuc. DRA yvrek USA k7. Cert6636 16023 Sninid y Ridge Rd. Chesterneld, N10 63017 Date: May 25,2023 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -- Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSi/rPH quality Criteria, DSB49 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Sufte 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641486 TTH126-132 T07A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:17 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB70Hg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJCW 1 0 Q 7 0 1 13-0-0 19-1 8 23-10-8 30-0-0 35 11-15 43-0-0 7-0-1 5-11-15 6-1-8 4-9-0 6-1-8 5-11-15 7-0-1 5x6 = 5.00 F12 5x8 = Scale = 1,75.1 3x8 = it cu n ro 15 cc 14 - — — 11 3x8 = 3x4 = 5x6 WB = 3x8 = 3x4 = 5x6 WB = 33-1-1 3x4 = 43-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC20201TP12014 CS]. TC 0.75 BC 0.96 WB 0.41 Matrix-SH DEFL. in (loc) I/deft Ud Vert(LL) -0.40 12-14 >999 240 Vert(CT) -0.70 12-14 >729 180 Horz(CT) 0.17 11 n/a n/a PLATES GRIP MT20 2441190 Weight: 227 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. 1-4,9-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP 285OF 2.0E or 2x4 SP M 31 'Except' WEBS 1 Row at midpt 5-15, 7-15. 8-14 13-16: 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=265(LC 11) Max Uplift 2=-944(LC 12), 11=-857(LC 12) Max Grav 2=1871(LC 17), 11=1819(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3900/2055, 3-5=-3656/1944, 5-6=-2629/1554, 6-7=2389/1507, 7-8=2633/1549, 8-10=-3669/1950, 10-11=-3914/2074 BOT CHORD 2-17=-1808/3727, 15-17=-1466/3104, 14-15=-1038/2387, 12-14=1455/2952, 11-12=-1805/3550 WEBS 3-17=-351/346, 5-17=-214/750, 5-15=877/557, 6-15=331/763, 7-14=-327/837, 8-14=-881/560, 8-12=-238/757, 10-12=354/365 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 19-1-8, Exterior(2E) This item has been 19-1-8 to 23-IG-8, Exterior(2R) 23-10-8 to 30-0-0, Interior(1) 30-0-0 to 42-10-4 zone; cantilever left and right exposed ; end vertical electronically signed and left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 sealed by Velez, Joaquin, PE 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific a Digital Signature. to the use of this truss component. using 4) Provide adequate drainage to prevent water ponding. Printed copies of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. document are not Considered 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide signed and sealed and the will fit between the bottom chord and any other members, with BCDL = IO.Opsf. signature nature must be verified 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at joint 11. on any electronic copies. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any Jaagala Velez PE \o.69132 particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." .LBrek Inc. DBA NHTek USA FL can 66_;4 16023 Sningley Ridge Rd. CkeelerGetd. MO 63017 Date: May 25,2023 WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19l2020 BEFORE USE. Design valid for use only with MRek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek^ is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUMI Quality Criteria, DSB-99 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T306417 48 TTH126-132 T09 Common Supported Gable 12 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:19 2023 Page 1 I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3N SgPgn L8w3u ITXbGKWrC Doi7J4zJC?f 1-0 q 21.6-0 43-M -0- 21-6-0 21-6-0 i1 5.00 12 5x6 = 13 14 Scale = 1:73.0 3x6 = 3x6 = 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 3x6 = 3x6 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BC(-L 0.0 Rep Stress Incr YES BC 10.0 Code FBC2020ITP12014 CSI. DEFL. in (loc) I/deft L/d TC 0.17 Vert(LL) -0.00 1 n/r 120 BC 0.18 Vert(CT) 0.00 1 n/r 120 WB 0.11 Horz(CT) 0.01 24 n/a n/a Matrix-SH PLATES GRIP MT20 244/190 Weight: 271 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 WEBS 1 Row at midpt 13-35, 12-36, 14-34 REACTIONS. All bearings 43-0-0. (lb) - Max Horz 2=297(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 36, 39, 40, 41, 42, 44, 34, 31, 30, 29, 28, 26, 24 except 37=-104(LC 12), 43=-104(LC 12), 45=153(1-C 12), 33=-104(LC 12), 27=-107(LC 12), 25=179(LC 12) Max Grav All reactions 250 lb or less at joint(s) 2, 35, 36, 37, 39, 40, 41, 42, 43, 44, 34, 33, 31, 30, 29, 1 28, 27, 26, 24 except 45=258(LC 17), 25=271(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 9-10=-113/307, 10-11=-128/376, 11-12=-152/448, 12-13=176/512, 13-14=176/512, 14-15=-152/448, 15-16=-128/376, 16-17=-104/307 WEBS 3-45=-180/332, 23-25=-186/377 NOTES- (12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=2ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3E) -1-0-0 to 3-6-0, Exterior(2N) 3-6-0 to 21-6-0, Comer(3R) 21-6-0 to 25-9-10, Exterior(2N) 25-9-10 to 43-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 36, 39. 40, 41 42, 44, 34, 31, 30, 29, 28, 26, 24 except 0=1b) 37=104, 43=104, 45=153, 33=104, 27=107, 25=179. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 24. 12) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." I$ This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaq,& Velez PE No.68182 \BTek inc. DBA iBTek l'SA F1. Cen 604 16023 Swioglep Ridge Rd. Chesterfield, CIO 63017 Date: May 25,2023 WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall _ building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing M iTe k is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS&TPI1 Quality CrUerfa, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641488 TTH126-132 T10 Common 27 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 2411:22:20 2023 Page 1 I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?P sB7OH g3NSgPgnL8w3uITXbGKWrCDoi7J4zJC?f �1-0-Q 7-7-3 14-6-10 21.6-0 28-5-6 35-4-13 43-0-0 Q4-0-Q -0- 7-7-3 6-11-6 6-11-6 6-11-6 6-11-6 7-7-3 5x6 = 5.00 12 Scale = 1:72.2 3x8 = it L2 to TO z4 zo l4 is to a iZ 3x8 = 3x4 = 4x6 = 3x4 = 3x4 = 4x6 = 3x4 = 1 I4 6 9 Ob 17-3-15 25-8-1 33-11-10 43-0-0 9-0E 8-3-10 8-4-1 5-3-10 9-0-6 Plate Offsets (X,Y)— [2:0-4-2,0-1-8], [4:0-3-0,Edge], [8:0-3-0,Edge], [10:0-4-2,0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.91 Vert(LL) -0.40 14-15 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(CT) -0.68 14-15 >751 180 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(CT) 0.18 10 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 218 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 "Except" TOP CHORD Structural wood sheathing directly applied. 1-4,8-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-298(LC 10) Max Uplift 2=-943(LC 12), 10=943(1-13 12) Max Grav 2=1885(LC 17), 10=1885(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3931/2002, 3.5=-3802/2010, 5-6=2890/1661, 6-7=2890/1661, 7-9=3802/2010, 9-10=-3932/2002 BOT CHORD 2-17=-170813783, 15-17=1306/3020, 14-15=-850/2218, 12-14=-130712872, 10-12=-1708/3560 WEBS 6-14=520/1153, 7-14=-763/574, 7-12=392/909, 9-12=362/365, 6-15=520/1153, 5-15=-763/574, 5-17=-392/908, 3-17=-362/365 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) 21-6-0 to 25-9-10, Interior(1) 25-9-10 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific electronically signed and to the use of this truss component. sealed by Velez, Joaquin, PE 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' using a Digital Signature. 5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL=10.opsf. Printed copies of this 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb) document are not considered 2=943, 10=943. signed and sealed and the 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any I Snature must be verified g particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." on any electronic copies. Jo.garo Velez PE Ne.68182 \siiek rat. DBA.NUTek USA FL Cert66.34 16023 Swfngley Ridge Rd. Ch.(-field, 1,10 63017 Dete: May 25,2023 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek" is ahvays required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641489 TTH126-132 T10A COMMON 16 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:22 2023 Page 1 ID:tPuYCeVfQTfYt30C?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3uITXbGKWrCDoi7J4zJC?f -,1-0-0 7-7-3 14-6-10 21-6-0 28-5-6 35-4-13 43-0-0 -0- 7-7.3 6-11-6 6-11 6 6-11-6 6-11 6 7-7-3 1 5x6 = 5.00 12 Scale = 1:72.2 3x8 = ,,. 11 - - 11 1.. , , 3x8 = 3x4 = 9-0-6 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020lrP12014 LUMBER - TOP CHORD 2x4 SP No.2 *Except* 1-4,8-10: 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=297(LC 11) Max Uplift 2=-944(LC 12), 10=-857(LC 12) Max Grav 2=1886(LC 17), 10=1831(LC 18) 4x6 = 3x4 = 3x4 = 4x6 = 3x4 = CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TC 0.94 Vert(LL)-0.4013-14 >999 240 MT20 244/190 BC 0.93 Vert(CT) -0.68 13-14 >750 180 WB 0.99 Horz(CT) 0.18 10 n/a n/a Matrix-SH Weight: 216 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3932/2003, 3-5=-3803/2012, 5-6=2892/1662, 6-7=2892/1671, 7-9=-3811/2048, 9-10=-3941/2041 BOT CHORD 2-16=-1752/3776, 14-16=-1350/3012, 13-14=-893/2210, 11-13=-132712872, 10-11=-1768/3571 WEBS 6-13=-521/1155, 7-13=-766/577, 7-11=422/916, 9-11=365/381, 6-14=520/1153, 5-14=-763/574, 5-16=-391/908, 3-16=-362/365 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) 21-&0 to 25-9-10, Interior(1) 25-9-10 to 42-10.4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=944. 10=857. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." jo This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE \o.691a2 -NETek rue. DBA 4BTe6 USA FI. Cert 6634 16W SwWgley Ridge Rd. CbesterrieW, NIO 63017 Date: May 25,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not, a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing T' ekn is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the M i l fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/f Quality Criteria, DS849 and SCSI Building Component 16023 Swingley Ridge Rd Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641490 TTH126-132 T11 Common 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:23 2023 Page 1 I D: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PSB7OH g3NSgPgn L8w3u ITXbG KWrC Do i7J 4zJC?f -,1-0-p 7-7-3 14-6-10 21-6-0 28-5-6 35-4-13 43-0-0 45-0-0 7-7-3 6-11 6 6-11 6 6-11-6 6-11E 7-7-3 211 5.o0 12 3x4 = 4x6 = 3x4 = 17-3-15 5x6 = 25-8-1 3x4 = 4x6 = 33-11-10 3x4 = 43-0-0 Scale = 1:73.7 LOADING (psf) TC4L 20.0 TCbL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TP12014 CSI, TC 0.91 BC 0.92 WB 0.99 Matrix-SH DEFL. in floc) I/deft L/d Vert(LL) -0.40 14-15 >999 240 Vert(CT) -0.68 14-15 >755 180 Horz(CT) 0.18 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 220 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 "Except' TOP CHORD Structural wood sheathing directly applied. 1-4,8-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-31O(LC 10) Max Uplift 2=939(LC 12), 10=1020(LC 12) Max Grav 2=1885(LC 17), 10=1934(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3930/1998, 3-5=-3800/2006, 5-6=2887/1656, 6-7=2886/1647, 7-9=3779/1968, 9-10=3921/1959 BOT CHORD 2-17=-1668/3791, 15-17=-1252/3027, 14-15=-827/2225, 12-14=-1281/2868, 10-12=-1668/3535 WEBS 6-14=-516/1150, 7-14=-758/569, 7-12=359/890, 9-12=-354/345, 6-15=-519/1153, 5-15=-763/575, 5-17=-392/908, 3-17=362/365 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vufl=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) 21-6-0 to 25-9-10, Interior(1) 25-9-10 to 45-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific electronically signed and to the use of this truss component. sealed by Velez, Joaquin, PE 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' using a Digital Signature. 5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. Printed copies of this 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) document are not considered 2=939,10=1020. 'This signed and sealed and the 7) manufactured product is designed as an individual building component. The suitability and use of this component for any signature must be verified particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." on any electronic copies. Joagnin Velez PE No.68182 :NITek 1uc. DDA hDTek USA FL Cert 6634 16023 Sningley Ridge Rd. Ckeslerfield, MO 63017 Date: May 25,2023 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek- is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641491 TTH126-132 Vol GABLE 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 5-6-8 2x4 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:24 2023 Page 1 ID: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3NSgPgnL8w3u ITXbG K WrC Doi7J4zJ C?f 11-1-0 TRUSS DESIGNED FOR WIND LOADS IN THE PLANE Scale = 1:17.8 04 —_ OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT 3 QUALIFIED BUILDING DESIGNER AS PER ANSIfTPI 1. 2x4 11 2x4 11 2x4 11 2x4 -- 11-1-0 11-1-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.17 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.13 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(CT) 0.00 5 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 38 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 11-1-0. (lb) - Max Horz 1=55(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 8=-184(LC 12), 6=184(LC 12) Max Grav All reactions 250 lb or less atjoint(s) 1, 5, 7 except 8=279(LC 1), 6=279(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-8=-187/368, 4-6=187/368 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vu@=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=3Dft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 5-6-8, Exterior(21R) 5-6-8 to 8-6-8, Interior(1) 8-6-8 to 10-3-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except This item has been (it=lb) 8=184, 6=184. electronically signed and 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jaagala Velez PE No.69132 NOTek Inc. DBA MITert USA FL Cert 66.44 16OLI SwisiI Ridge Rd. Ckester8eld.N1O 63017 Dnte: May 25,2023 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ` Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Crfterra, DSB-99 and BCS/ Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641492 TTH126-132 V02 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, d d 3x4 i 2x4 II 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:24 2023 Page 1 ID: tP uYCeVfQTft30C?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3u lTXbGK WrCDoi7J4zJC?f 8-0-0 4-0-0 4x4 = 3x4 Scale = 1:14.6 :d d 7-11-6 8-0,-0 7-11-6 0 10 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) n/a n/a 999 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.27 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 24 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=7-10-13, 3=7-10.13, 4=7-10-13 Max Horz 1=37(LC 11) Max Uplift 1=-64(LC 12), 3=64(LC 12), 4=-133(LC 12) Max Grav 1=107(LC 21), 3=107(LC 22), 4=273(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-169/308 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. III; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=lb) 4=133. This item has been 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any electronically signed and particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. I—gmia Velez PE No.68182 MiTek Inc. DDA NUTek USA FL Cer16634 16023 Saiogley Ridge Rd. Chesterfield. -MO 63017 Dare: May 25,2023 A WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev, 5/19/2020 BEFORE USE, Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Et building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUMI Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641493 TTH126-132 V03 Valley 2 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:25 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 2-0-0 4-0-0 2-0-0 2-0-0 cY d 2x4 i 5.00 12 3x6 = 2x4 Scale = 1:7.6 4-0-0 Plate Offsets (X,Y)-- [2:0-3-0 Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.12 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 10 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SIP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2x4 SIP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-0-0, 3=4-0-0 Max Horz 1=-14(LC 10) Max Uplift 1=-50(LC 12), 3=-50(LC 12) Max Grav 1=92(LC 1), 3=92(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16: Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=451t; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. J—pri. Velez PE No.68182 WTek Luc. DBA NUTek USA YT. Cen 66.14 16023 Sningley Ridge Rd. ClicAcrfietd. MO 63017 Dare: May 25,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mirek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVM1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Tmss Plate Instilute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 6307 Job Truss Truss Type Qty Ply T30641494 TTH126-132 VO4 GABLE 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:26 2023 Page 1 ID: tP uYCeVfQTfYt30C?ZvfnpzlG U H-RfC?P sB7OH g3NSg PgnL8w3u ITXbGK WrC Doi7J4zJC?f 2-1-8 4-3-0 2x4 - 2x4 4-3-0 Plate Offsets (X,Y)— [2:0-3-0,Edgej LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Ina YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020rrP12014 Matrix-P Weight: 11 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-3-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-3-0, 3=4-3-0 Max Horz 1=-16(LC 10) Max Uplift 1=-55(LC 12). 3=55(1-C 12) Max Grav 1=101(LC 1), 3=101(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint($) 1, 3. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jongrde Velez PE N..68182 MiTek lue. DBA YHTek GSA FL Cent 4634 1602-1 Swiugley Ridge Rd. C►-lerfiekl. N14D 0017 Drre: May 25,2023 WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -- Design valid for use only with MiTak® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPIS Quality Cr iteNa, DSB89 and BCSI Building Component 16023 Swingley Ridge Rd Sa/etyln►ormatlon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641495 TTH126-132 V05 GABLE 1 1 Jab Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:27 2023 Page 1 I D: tPuYCeVfQTtYt3OC?ZvfnpzlGU H-RfC?P sB7OH q3N Sg PgnL8w3u ITXbGK WrC Doi7J4zJC.7f 4-0-8 9-1-0 ' 4-" 4-6-8 Scale = 1:16.7 TRUSS DESIGNED FOR WIND LOADS IN THE PLANE 4x4 — OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT QUALIFIED BUILDING DESIGNER AS PER ANSI/TPI 1. -A d 8 7 6 2x4 i:�; 2x4 11 2x4 11 2x4 11 2x4 9-1-0 9-1-0 —1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.10 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.08 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 5 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 30 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 9-1-0. (lb) - Max Horz 1=-43(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-127(LC 12), 6=-127(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7, 8, 6 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-8=-142/301, 4-6=-142/301 NOTES- (8) 1) unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuk=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFIRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-6-8, Exterior(21R) 4-6-8 to 7-6-8, Interior(1) 7-6-8 to 8-3-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will Ft between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) This item has been 6=127, 6=127. electronically signed and 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagata Felez PE No.69132 NBTek lae. DBA NliTek USA FL Ceri 6634 1602.1 Swingley Rids. Rd. Chesterfield. N10 63017 D.w May 25,2023 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -- Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek^ is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUMI Quality Criteria, DS849 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641496 TTH126-132 V06 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:27 2023 Page 1 I D: tPuYC eVfQTfYt3OC?ZvfnpzlG U H-RtC?PsB7OHg3N SgPgn L8w3u ITXbG KWrC Doi7J4zJC?f 2-6-8 5-1-0 2-6-8 2-6-8 5.00 F12 2x4 3x6 = 2x4 Scale = 1:9.8 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TP12014 CSI. TC 0.15 BC 0.26 WB 0.00 Matrix-P DEFL. in (loc) I/defl Ud Vert(LL) n/a n/a 999 Vert(CT) n/a n/a 999 Horz(CT) -0.00 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 13 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1-0 oc purlins. BOT CHORD 2x4 SIP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-11-13, 3=4-11-13 Max Horz 1=-21(LC 10) Max Uplift 1=-72(LC 12), 3=-72(LC 12) Max Grav 1=132(LC 1),3=132(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-148/287, 2-3=148/299 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vutt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any This item has been particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joegrda Vere. PE N..69152 \LTek lac DBA ilDTek USA FL Cen riO4 1602.3 Stttagtey Ridge Rd. Chesterfield. 1,%10 63017 Date: May 25,2023 AL WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/192020 BEFORE USE. " Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M�Tek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUM1 Quality Criteria, DSB-89 and BCS/ Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply T30641497 TTH126-132 V07 GABLE 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, e 0 0 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:28 2023 Page 1 ID: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PSB70H g3NSgPgn L8w3u ITXbG K WrC Doi7J4zJC?f 4x4 = TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND 5 (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICARLF OR CONSIILT 3x4 - 16 15 14 13 12 11 10 3x4 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 14-7-8 14-7-8 CSI. DEFL. in floc) I/deft Ud TC 0.09 Vert(LL) n/a n/a 999 BC 0.08 Vert(CT) n/a n/a 999 WB 0.07 Horz(CT) 0.00 9 n/a n/a Matrix-SH Scale = 1,23.7 PLATES GRIP MT20 2441190 Weight: 64 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 14-7-8. (lb) - Max Horz 1=112(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 14, 15, 12, 11 except 16=146(1-C 12), 10=146(1-C 12) Max Grav All reactions 250 lbor less at joint(s) 1, 9, 13, 14, 15, 16, 12, 11, 10 .g d FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vutt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 7-3-12, Exterior(2R) 7-3-12 to 10-3-12, Intedor(1) 10-3-12 to 13-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 14, 15, 12, This item has been 11 except (jt=lb) 16=146, 10=146. electronically signed and 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joxgrda Velez PE \0.68182 Nglek fnr. DBA \iiT.k USA FL Cem 66.14 16023 Swingley Ridge Rd. Ckesterfreld, MG 63017 D.tec May 25,2023 A WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTekn is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117P/1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Saingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641498 TTH126-132 V08 Valley t 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:29 2023 Page 1 ID: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3N SgPgnL8w3uITXbGKWrC Doi7J4zJC?f 5-7-12 11-3-8 5-7-12 5-7-12 4x4 i 2x4 11 4x6 = 4x4 -- Scale = 1:19.6 .g d 11-3-0 11 -8 11-3-0 0- -8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 37 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 1=11-2-8, 3=11-2-8, 4=11-2-8 Max Horz 1=-84(LC 10) Max Uplift 1=104(LC 12), 3=104(LC 12), 4=-196(LC 12) Max Grav 1=169(LC 21), 3=169(LC 22), 4=411(LC 1) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 1D-0-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. WEBS 24=-251/355 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 5-7-12, Exterior(2R) 5-7-12 to 8-7-12, Interior(1) 8-7-12 to 10-7-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) This item has been 1=104, 3=104, 4=196. electronically signed and 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code" using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joegaie Velez PE No.68182 N11Tek Iuc. DBA N11Tek USA FL Cen 6634 16023 Svringley Ridge Rd. Cbesterrield. NIO 63017 Date: May 25,2023 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -- Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not �4 a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall T building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M le k is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUFF11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641499 TTH126-132 V09 Valley 1 1 Job Reference (optional) Builders Firssource (Tampa, FL), Tampa, FL - 33564, a d 3x4 i 2x4 II 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 2411:22:30 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC? P sB7OH q3 N Sg PgnL8w3ulTXbGKWrC Doi7J4zJ C?f 7-11-8 3-11-12 4x4 = 3x4 Scale = 1:14.7 .a d 7-11-0 0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.32 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 25 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or B-0-0 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=7-10-8, 3=7-10-8, 4=7-10-8 Max Horz 1=56(LC 11) Max Uplift 1=-69(LC 12), 3=69(LC 12). 4=-131(LC 12) Max Gram 1=113(LC 21), 3=113(LC 22), 4=275(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-167/293 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vint=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 3-11-12, Exterior(21R) 3-11-12 to 6-11-12, Interior(1) 6-11-12 to 7-3-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=lb) This item has been 4=131. electronically signed and 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code" using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagnle Velez PE Po.68182 XgTek Luc. DBA 3111ek USA FL Cert 6634 16023 Satngley Ridge Rd. Cheaterrield. MO 63017 Me: May 25,2023 a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek^ is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley, Ridge Rd Safely Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply T30641500 TTH126-132 V10 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, e 0 2x4 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:30 2023 Pagel ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 4-7-8 3x6 = 2 2x4 Scale = 1:8.6 t9 d 0- 4-7-0 Plate Offsets (X,Y) - [2:0-3-0,Edgel LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) 1/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) n/a rile 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.23 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-6-8, 3=4-6-8 Max Horz 1=-28(LC 10) Max Uplift 1=-68(LC 12), 3=68(1-C 12) Max Grav 1=125(LC 1), 3=125(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30f; eave=4ff; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Juagate Velez PE \0.68182 WTek 1— DBA NUT& USA FL C.m 66.14 16023 Svninglec Ridge Rd. Ch.f-&Id, A10 63017 Date: May 25,2023 A WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPN Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Sarety/Mormation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City T30641501 TTH126-132 V11 Valley 1 jli�Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:31 2023 Page 1 I D:tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?P sB70Hg3N SgPgn L8w3u ITXbGKWrC Doi7J4zJC?f 3-10-0 7-8-0 3-10-0 3-10-0 b d 3x4 2x4 II 4x4 = 3x4 Scale = 1:14.2 7-8-0 7-8-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.15 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 23 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=7-8-0, 3=7-8-0, 4=7-8-0 Max Horz 1=-35(LC 10) Max Uplift 1=-60(LC 12), 3�60(LC 12), 4=-127(LC 12) Max Grav 1=102(LC 21), 3=102(LC 22), 4=258(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-159/296 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16: Vint=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except Gt=lb) 4=127. This item has been 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any electronically signed and particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. doagnia Velez PE Fa.69132 3dITek1ae.DBAb11Tek USA FI.Cer16634 16023 Sniagley Ridge Rd. Ckeererfreld, MO 63017 Dare: May 25,2023 O WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev, 5/19/2020 BEFORE USE. Design valid for use only with MrrekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPlf Quality Crltede, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Symbols Numbering System ; `', General Safety Notes PLATE LOCATION AND ORIENTATION " Center plate on joint unless x, y 4 offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) Failure to Follow Could Cause Property Damage or Personal Injury Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system, e.g. Apply plates to both sides of truss 1 2 3 diagonal or X-bracing, is always required. See BCSI. and fully embed teeth. TOP CHORDS 2. Truss bracing must be designed by an engineer. For c1-2 c2-3 wide truss spacing, individual lateral braces themselves bracing, Tor I WEBS Q 4 p� may require or alternative bracing should be considered. 3. Never exceed the design loading shown and never U" a� N O stack materials on inadequately braced trusses. U 4. Provide this truss design to the building copies of designer, erection supervisor, property owner and For 4 x 2 orientation, locate c7-e ce-i ce-6 BOTTOM CHORDS all other interested parties. plates 0- 111 ' from outside 5. Cut members to bear tightly against each other. edge of truss. 8 7 6 5 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE locations are regulated by ANSI/TPI 1. required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 7. Design assumes trusses will be suitably protected from connector plates. THE LEFT. the environment in accord with ANSI/TPI 1. Plate location details available in MiTek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 8. Unless otherwise noted, moisture content of lumber software or upon request. NUMBERS/LETTERS. shall not exceed 19 % at time of fabrication. 9. Unless expressly noted, this design is not applicable for PLATE SIZE PRODUCT CODE APPROVALS use with fire retardant, preservative treated, or green lumber. ICC-ES Reports: 10. Camber is a non-structural consideration and is the The first dimension is the plate responsibility of truss fabricator. General practice is to 4 x 4 width measured perpendicular ESR-1311, ESR-1352, ESR1988 camber for dead load deflection. to slots. Second dimension is ER-3907, ESR-2362, ESR-1397, ESR-3282 11. Plate type, size, orientation and location dimensions the length parallel to slots. indicated are minimum plating requirements. LATERAL BRACING LOCATION 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. Indicated by symbol shown and/or by text in the bracing section of the Trusses are designed for wind loads in the plane of the truss unless otherwise Shown. 13. Top chords must be sheathed or pudins provided at spacing indicated on design. output. Use T or I bracing if indicated. Lumber design values are in accordance with ANSI/TPI 1 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. section 6.3 These truss designs rely on lumber values BEARING established by others. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior Indicates location where bearings approval of an engineer. (supports) occur. Icons vary but reaction section indicates joint © 2012 MiTek® All Rights Reserved 17. Install and load vertically unless indicated otherwise. number where bearings occur. Min size shown is for crushing only. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. Industry Standards: W1 19. Review all portions of this design (front, back, words ANSI/TPI1: National Design Specification for Metal and pictures) before use. Reviewing pictures alone is not sufficient. Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. 20. Design assumes manufacture in accordance with BCSI: Building Component Safety Information, MiTek ANSI/TPI 1 Quality Criteria. Guide to Good Practice for Handling, Installing & Bracing of Metal Plate 21.The design does not take into account any dynamic Connected Wood Trusses. MiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020 or other loads other than those expressly stated. BEARING HEIGHT 56HEDULE 139-06-00 5-00-00 14-08-00 19-90-00 19-00-go 19-00-00 19-00-00 19-08-00 14-00-00 5-00-06 Hanger List — H1 HTU26 2-(0-10E2- H2 IUS3.56/16 cI iil0($1 -ram—. T,�01 1 T�111$1 r�l CIA H3 IUS2.37/16 C38 C319, . J NOTES: 1.) REFER TO HID Q1 (RECOMMENDATION5 FOR HANDLING INSTALLATION AND TEMPORARY BRACING.) REFER TO ENGINEERED DRAWING5 FOR PERMANENT - - - _ - BRACING REQUIRED. 2.) ALL TRU55E5 (INCLUDING TRU55E5 UNDER VALLEY FRAMING) ML15T BE COMPLETELY l ( DECKED OR REFER TO DETAIL Y105 FOR $ I ALTERNATE BRACING REQUIREMENTS. I _., 3.) ALL VALLEYS ARE TO BE CONVENTIONALLY FRAMED BY BUILDER. 4.) ALL TRU55E5 ARE DESIGNED FOR 2' o.c. MAXIMUM 5PACIN6, UNLE55 OTHERWISE NOTED. 5.) ALL WALLS 5HOWN ON PLACEMENT PLAN ARE CON51DERED TO BE LOAD BEARING, UNLE55 OTHERWISE NOTED. 6.) 5Y42 TRU55E5 MUST BE IN5TALLED WITH THE TOP BEING UP. IIII 7.) ALL ROOF TRU55 HANGERS TO BE 51MP50N _ ,Z?`' - �e" V l �s HTU26 UNLE55 OTHERWISE NOTED. ALL FLOOR TRU55 HANGERS TO BE 51MP50N c3R ' = 1-6 L THA422 UNLE55 OTHERWISE NOTED. Vg - ct =- _ -- -- ,, - ,a. 1 - CIA 8.) DEAM/HEADER/LINTEL (HOR) TO BE FURN15HED BY IDUILDER. U5-00-00 1- 0-00 SHOP DRAWING APPROVAL 14-08-00 19-08-00 3-09- 4-00- 4-02-00 4-00-e0 3-09- 19-00-00 19-06-00 19-ee-ee I.. s-ee-ee THI5 LAYOUT 15 THE 50LE 50LRCE FOR FABRICATION OF 139-06-00 TRU55E5 AND VOIDS ALL PREVIOU5 ARCHITECTURAL OR OTHER TRU55 LAYOUTS. REVIEW AND APPROVAL OF THI5 LAYOUT MAT BE RECEIVED BEFORE ANY TRU55E5 WILL BE DMLT. VERIFY ALL DITIONS CONTO INSURE AGAIN5T CHANGES THAT WILL RE5ULT IN EXTRA CHAR6E5 TO YOU. tgra[<d Deircrr Dau Armored It: Wtc Builders .Fir o stS urc e Products Orlando PHONE: 407-851-2100 FAX: 407-851-7111 PIotID Length Product Plies Net Oty Fab TLJPE Plant City FJ I 20-00-00 16" BCI 4500s-1 8 2 14 MFD PHONE: 613-759-51151 FAX: 613-752-1532 FJ2 5-00-00 16' BCI 4500s-1.8 2 14 MFD FJ3 20-00-00 16" BCI 6000s-1.8 1 77 MFD FJ4 20-00-00 16 BCI 6000s-1.8 1 14 MFD FJ5 16-00-00 16" BCI 6000s-I.8 1 49 MFD FJ6 4-00-00 16" BCI 6000s-1.8 1 7 MFD BUILDER: Rm 1 12-00-00 1-1/8" x 16" BC RIM BOARD OSB 71 FF Starlight Homes Bk 1 2-00-00 16" BCI 6000s-1.8 1 70 FF Tys�DE1i TH 7Unit A Connector Summary LHALAPon ccristae: Oty Manuf Product Flange Supported Mbr Fastener�op Nails Supporting Mbr FastenerBacker Blocks Web Stiff Skew Slope Supporting Mil Supported Mtl Lot 126-132 50uE: NT5 14 Simpson IUS2.37/ 16 None - - - No No - - SCL 16" BCI 6000s-1.8 DATE: DEAN OY: d00 A: 7 Simpson IUS3.56/ 16 None - - - No No - - SCL 2- 16" BCI 4500s 1.8 5-23-23 Rick BEARING HEIGHT 5GHEDULE 139-08-00 19-08-00 19-08-00 19-08-00 19-08-00 19-08-00 19-08-00 19-08-00 Products PIotID Length Product Plies Net, Otg Fab Typ FJ1 20-00-00 16" BCI 4500s-1.8 2 14 MFD FJ2 5-00-00 16" BCI 4500s-1.8 2 14 MFD FJ3 20-00-00 16" BCI 60005-1.8 1 77 MFD FJ4 20-00-00 16' BCI 6000s-1.8 1 14 MFD FJ5 16-00-00 16' BCI 6000s-1.8 1 49 MFD FJ6 4-00-00 16' BCI 6000s-1.8 1 7 MFD Rrn l 12-00-00 1-1 /8" x 16" BC RIM BOARD OSB 71 FF Bkl 2-00-00 16" BCI 6000s-I.8 1 70 FF Connector Summary Oty Manuf Product Flange Supported Mbr Fastener$op Na11s Supporting Mbr Fastener -Backer Blocks Web Stiff Skew S 14 Simpson IUS2.37/16 None - - No No - - 7 Simpson IUS3.56/16 None - - No No - - Supporting Mtl Supported MU SCL 16' BCI 6000s-1.8 SCL 2- 16" BCI 45005 1.8 Hanger List H1 HTU26 H2 IUS3.56/16 H3 IUS2.37/16 NOTES: 1.) REFER TO HID 91 (RECOMMENDATION5 FOR HANDLING INSTALLATION AND TEMPORARY BRACING.) REFER TO ENGNEERED DRAWINGS FOR PERMANENT BRACING REQUIRED. 2.) ALL TRUSSES (INCLUDING TRU55E5 UNDER VALLEY FRAMIN6) ML15T BE COMPLETELY DECKED OR REFER TO DETAIL V105 FOR ALTERNATE BRACING REQUIREMENTS. 3.) ALL VALLEYS ARE TO BE CONVENTIONALLY FRAMED BY BUILDER. 4.) ALL TRUSSES ARE DESIGNED FOR 2' o.c. MAXIMUM 5PACIN6, UNLE55 OTHERWISE NOTED. 5.) ALL WALL5 SHOWN ON PLACEMENT PLAN ARE CONSIDERED TO BE LOAD BEARING, UNLESS OIHERW15E NOTED. 6,) SY42 TRUSSES MUST BE INSTALLED WITH THE TOP BEING UP. 7.) ALL ROOF TRUSS HAN6ER5 TO BE SIMPSON HTU26 UN.E55 OTHERWISE NOTED, ALL FLOOR TRU55 HANGERS TO DE 51MP50N THA422 UNLE55 OTHERWISE NOTED. 8.) BEAM/HEADER/LINTEL (KOR) TO BE FURNISHED BY BUILDER, SHOP DRAWING APPROVAL THIS LAYOUT 15 THE 50LE SOURCE FOR FABRICATION OF TRU55E5 AND VOID5 ALL PREVIOU4 ARCHITECTURAL OR OTHER TRU55 LAYOUTS. REVIEW AND APPROVAL OF THIS LAYOUT MKT DE RECEIVED BEFORE ANY TRU55E5 WILL DE BUILT, VERIFY ALL CONDITION5 TO INSURE AGAINST CHANGE5 THAT WILL RESULT IN EXTRA CHARGES TO YOU, GQZZEKS11'I1M I Arrl-d by, Dnr I 61BUilderS s Fir tSource Orlando PHONE: 407-851-2100 FAX 407-851-7111 Plant City PHONE: 813-754-5Q51 FAX: 813-752-1532 Starlight Homes TH 7LInit A Lot 126-132 5-23-23 I Rick DESCRIPTION: LOT(S)126-132 TYSON TOWNHOMES, ACCORDING SEC. 2, TWP. 26 S, RNG 21 E. TO THE PLAT THEREOF, RECORDED IN PLAT BOOK PAGE(S)_, OF SITE PLAN PASCO COUNTY, FLORIDA THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. (NOT A SURVEY) (TYSON TOWNHOMES) This SITE PLAN Prepared for and Certified To: LEGEND: Starlight Homes PROPOSED DRAINAGE FLOW + 00.00 = PROPOSED GRADE I 1. • . I I I t I I I I I I I I ' = 10.00' UTILITY EASEMENT I I I I — •' I 125 i 124 i 123 i 126 Scale: 1 20 I NOTES:44 LOT GRADING TYPE =N/A i N 89°47'39' E (P) 77.69' (P)------ PROPOSED PAD ELEVATION = 100.30' I w NOTE FROM SET BACK = 20' * I w ° 18 9' NO LOT GRADES PER PLAN SIDE SET BACK = 10' REAR SETBACK = 15' t 0 0• yk..o , 2 .0' 43.0 � O • RESIDENCE -.1 C vj .p N PROPO ag PUl Sr+R 126 I 1.a p iP 13 EIfV DEFT .,. ••. .. j.7' ENTRY GPRPC'E 10.0' . 45.0� P 4o .0'-o 0 0 O? i •.A 9450 • o OSED RESIDENCE 127 �- A/C pROP138T p1EBU ELEG -EFT Z O ! - i : :.. • 3.7 ENTRY GAR/` 0, — v y ,. m • .. i• :. .,� • � 45 ,d o N o Z � O - 6 o 9. P 45 0 00, 0 N In PROPOSED U\_SIPA 128 N 2:� -1 O �r; � � ..' • 'O N 13 EEEv VIREFTWp- ENTRY C,ARPGE �, �' N � �3 c P . o *3.7' NC D . o 45 �, • : •-6 32.8' — � ESIDENCE � -p S 88°58'59- E (P) I , 1 � PROPOSE NEgU� 129 �1 0 19.00' (P) -A. '° ENTRY 138E`GE GNt p.0' o COMM 20' (P) 3.7' GAM ' N 45.0.. � •. - c PCP (P) :'.. �' o In 4 o'. O : O A. 45.0 E .o 0' .''. w. POSED ESIDENC -.1.. .4 . .. PROPOS PUI-sPR 130 PCP (P)13 EIEV T N S 64°51'53" W (P) . �• 3.7 ENTRY GGELEF a' SED RESIDENCE p o J 11.1 0 O O Q o 0 N N w 0 Z Qw w 0° m m � o 0 O � `N^ Z w J O C O P n V d M F- 0 w J W O � Q u; m LOT = 15450 SO. FT. S -Try'' m PROP�87 NEgU 131 LIVING AREA = 3637 SO. FT. 2 ENTRY AGE -RIGHT D0. V) ENTRY = 187 SO. FT. \ 33' GP 2 o 0 N NC []OO GARAGE = 1331 SO. FT. o�' . • .. ' o . o COVERED LANAI = XXX SO. FT. 45 p' m PATIO = 240 SO. FT. yo ��� .:_A POOL AREA = NA SO. FT. s RESIDENCE y Y c '��' W OPOSED SW .I p CONC. DRIVE = 1551 SO. FT. PR 1386P V N 132 �$ b' m ul A/C & CONC PAD = 56 SO. FT. ��, Cc<` ENTR GOtJGNT .0 U U U SIDEWALK = 993 SO. FT. � • • • d. N GP J SIDE YARD SWALE = XXX SO. FT. �� S �� ' o ' v 43'0 CONSERVATION AREA = XXX SO. FT. •. .. ' • ; �� LOT OCCUPIED = 51 % o A \'•' • 2 AREA TO IRRIGATE = 49 % ' • �' �' 10' UTILITY & SIDEWALK PROPOSED: 3 \e� EASEMENT MINIMUM FLOOR ELEVATIONS: \. sb���5 =WATER LIVING AREA:100.97' GARAGE AREA: NOTE 133 METERS ELEVATIONS REFERENCED TO A \ NO LOT GRADES PER PLAN NORTH AMERICAN VERTICAL < . DATUM OF 1988 �. \ APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY NO. 120235 SURVEY ABBREVATIONS �\ (MAP NUMBER 12 10 1 C-0456-F) EFFECTIVE DATE: 09/26/2014 AI = ARC LENGTH IDi = DEED INV = INVERT PC = POINT OF CURVE iRi = RECORD LEGEND A/C =AIR CONDITIONER D.E= DRAINAGE EASEMENT LB -LICENSED BUISNESS PCC - POINT OF COMPOUND CURVE RNG = RANGE r,' r,:; •. VINYL FENCE AF =ALUMINUM FENCE ��' j• CONC EL OR ELEV =ELEVATION L.E LANDSCAPE EASEMENT PCP =PERMANENT CONTROL POINT RRS = RAIL ROAD SPIKE =:r f..•'•� BFE = BASE FLOOD ELEVATION EOP - EDGE OF PAVEMENT LFE = LOWEST FLOOR ELEVATION P/E = POOL EQUIPMENT R/W = RIGHT OF WAY BM = BENCH MARK WOOD FENCE ESM'T =EASEMENT LS =LICENSED SURVEYOR PG =PAGE SEC =SECTION _ C =CURVE r = ASPHALT ICI =CALCULATED F/C =FENCE CORNER IMI =MEASURED PI = POINT OF INTERSECTION SN&D =SET NAIL AND DISK FCM = FOUND CONCRETE MES = MITERED END SECTION PK =PARKER KALON LB#8I83 r. = CENTERLINE CHAIN LINK FENCE CLF = CHAIN LINK FENCE MONUMENT NCF = NO CORNER FOUND R = PROPERTY LINE SIR - SET 1/2• IRON ROD LB# 8183 FIP = FOUND IRON PIPE O/A = OVERALL POB = POINT OF BEGINNING TBM = TEMPORARY BENCH MARK = BRICK X X CMP = CORRUGATED METAL PIP FIR = FOUND IRON ROD OHW = OVERHEAD WIRES POC = POINT OF COMMENCTMENT COL=COLUMN II TOB=TOP OF BANK CONC = CONCRETE FN&D = FOUND NAIL & DISK O.R. = OFFICIAL RECORDS POL = POINT ON LINE TWP = TOWNSHIP ALUMINUM FENCE C/S = CONCRETE SLAB FOP = FOUND OPEN PIPE IPI = PLAT PRC = POINT OF REVERSE CURVE U.E = UTILITY EASEMENT ®= COVERED \� CST = CLEAR SIGHT TRIANGLE FPP = FOUND PINCHED PIPE PB = PLAT BOOK PRM = PERMANENT REFERENCE MONUMENT VF - VINYL FENCE JOB # SURVEYOR'S NOTES: SURVEYOR'S CERTIFICATE 1708 Water Oak Drive SSEE 1.) Current title information on the subject property had not been This certifies that sketch of the hereon described Tarpon Springs, Florida vse " a, Date of Plan:5-17-23 furnished to Initial Point Land Surveying, LLC. at the time of this property was m4�01 i`kyNllfy�upervision and Phone: (727)-831-1990 TWP. I.N TWP. I.N. F SITE PLAN RG.I.W RG.I.E. DWG:L126-132 TSYON TH-SIT meets the w im 6rfi ractice for FloridaPLS7123@gmail.com E y TWP.1.5. TWP.I.S 2.) This sketch was prepared without the benefit of a title search. Jj_rve. y ; by)r,of L�3t�d LB# 8183 :o RG I W RG i E. No instruments of record reflecting ownership, easements or 1n tJJJ eCl oG,DE 5 File: rights -of -way were furnished to the undersigned, unless otherwise FI i df. ; 2rtley Drawn by: DJB shown hereon. pursuant to ection " 72 7 Flo i a S aa� 3.) Roads, walks, and other similar items shown hereon were taken Fi I ate: r1 ?L15.24 Checked by:JH from engineering plans and are subject to survey. �yE a�,4. This SITE PLAN does not reflect nor determine ownershi 13:08:3 8, 00, REVISIONS 5.) This SITE PLAN is subject to matters shown on the Plat of OF QQ 'TYSON TOWNHOMES" Jeff M. It 6.) Dimensions shown hereon are in feet and decimal portions FLORIDA ND Q thereof Contractor and owner are to verify all setbacks, building MAPPER NO' �L�k �i►� dimensions, and layout shown hereon prior to any construction, NOT VALID WITHOUT THE ORIGINAL and immediately advise Initial Point Land Surveying, LLC. of any SIGNATURE AND SEAL OF A FLORIDA v11 deviation from information shown hereon. Failure to do so will be LICENSED SURVEYOR AND MAPPER Initial Point Land Surveying, LLC. at user's sole risk.