Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6144-6174 Calle Ochoa St (2)
MiTM kLqmber design values are in accordance with ANSI/TPI 1 section 6.3 hese truss designs rely on lumber values established by others. iel/- RE: TTH56-63 - MiTek, Inc. Site Information: 16023 Swingley Ridge Rd. Id Customer Info: Starlight Homes Project Name: Bldg 9 Lots 56-63 Model: Bldg 9 L P4?�3 1260 O 63017 Lot/Block: 56-63 Subdivision: Tyson Address: ., City: Zephyrhills State: Florida Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.5 Wind Code: ASCE 7-16 Wind Speed: 150 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 32 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date No. Seal# Truss Name Date 1 T31961906 C1A 10/27/23 15 T31961920 T06A 10/27/23 2 T31961907 MA 10/27/23 16 T31961921 T07 10/27/23 3 T31961908 CJ 1 10/27/23 17 T31961922 T07A 10/27/23 4 T31961909 CJ3 10/27/23 18 T31961923 T09 10/27/23 5 T31961910 EJ5 10/27/23 19 T31961924 T10 10/27/23 6 T31961911 HJ5 10/27/23 20 T31961925 T10A 10/27/23 7 T31961912 T01 10/27/23 21 T31961926 T11 10/27/23 8 T31961913 T02 10/27/23 22 T31961927 V01 10/27/23 9 T31961914 T03 10/27/23 23 T31961928 V02 10/27/23 10 T31961915 T04 10/27/23 24 T31961929 V03 10/27/23 11 T31961916 T04A 10/27/23 25 T31961930 VO4 10/27/23 12 T31961917 T05 10/27/23 26 T31961931 V05 10/27/23 13 T31961918 T05A 10/27/23 27 T31961932 V06 10/27/23 14 T31961919 T06 10/27/23 28 T31961933 V07 10/27/23 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource - Plant City. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2025. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 0 PQU I N • VF�''ii i S No 68182 �-33 ' STATE OF .' 4/ XN "'11111111101 J..qW. % c1 z PE So.68182 NUTA 1— DBA Nlffek LSA FL Col 6634 16023 Seingley Ridge Rd. Che,tc rkld. N10 63017 Dale: October 27,2023 Velez, Joaquin 1 of 2 MlmTeko MiTek, Inc. RE: TTH56-63 - 16023 Swingley Ridge Rd. Chesterfield, MO 63017 314.434.1200 Site Information: Customer Info: Starlight Homes Project Name: Bldg 9 Lots 56-63 Model: Bldg 9 Lots 56-63 Lot/Block: 56-63 Subdivision: Tyson Address: ., City: Zephyrhills State: Florida No. Seal# Truss Name Date 29 T31961934 V08 10/27/23 30 T31961935 V09 10/27/23 31 T31961936 V10 10/27/23 32 T31961937 V11 10/27/23 2 of 2 Job Truss Truss Type Qty Ply T31961906 TTH56-63 C1A Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 2617:06:11 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-RfC?PsB7OHg3NSgPgnL8w3u ITXbGKWrCDoi7J4zJC-4 -1-0.0 1-7-10 1 0 0 1-7-10 Scale = 1:9.0 2x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.12 Vert(LL) -0.00 2 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.03 Vert(CT) -0.00 2 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight: 7 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-7-10 oc puffins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=D-3-8, 4=Mechanical Max Horz 2=82(LC 12) Max Uplift 3=-26(LC 9), 2=-122(LC 12) Max Grav 3=31(LC 17), 2=132(LC 1), 4=32(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 26 lb uplift at joint 3 and 122 lb uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joegnbt Velez PE No.68182 N71Tek Inc. DBA JBTek USA FL Cert ti6M 16023 Svingley Ridge Rd. Chesterfield. MO 6301' Datr: October 27,2023 WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropertyy damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIlTPIt Quality Criteria and DSB-22 available from Truss Plate Institute (www.lpinsl.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961907 TTH56-63 C3A Jack -Open 4 1 Job Reference (optional) Builders Firssource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:12 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -1-0-0 3-3-10 1-0-0 3-3-10 Scale = 1:13.2 2x4 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.26 BC 0.11 WB 0.00 Matrix-P DEFL. in floc) I/deft L/d Vert(LL) -0.01 2-4 >999 240 Vert(CT) -0.01 24 >999 180 Horz(CT) -0.00 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-3-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=126(LC 12) Max Uplift 3=-80(LC 12), 2=138(LC 12) Max Grav 3=81(LC 17), 2=188(LC 1), 4=62(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; VuH=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-2-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3 and 138 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code" This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joegnie Velez PE No.68182 ktlTek 1— DBA.MiTek USA FL Cm 6614 16023 Ssiugley Ridge Rd. CheA. field. \10 63017 Dale: October 27,2023 a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must vent' the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and pproperrtyry damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T31961908 TTH56-63 CA Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:13 2023 Page 1 ID:tPuYCeVfQTtYt3OC?ZvfnpzlGU H-RfC?PsB70Hg3NSgPgnL6w3ulTXbGKWrCDoi7J4zJC?f 1-0-0 1-4-14 Scale = 1:7.4 2x4 = 1-4-14 1-4-14 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.12 Vert(LL) -0.00 2 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 2 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight: 6 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-4-14 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=65(LC 12) Max Uplift 3=-17(LC 9), 2=-129(LC 12) Max Grav 3=19(LC 17), 2=127(LC 1), 4=27(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 17 lb uplift at joint 3 and 129 lb uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE N..68182 Atiiek Iaa. DBA JRTek USA FL Cert 6634 16023 Sssiogley Ridge Rd. Chesterfield. 3f0 63017 Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 11212023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. � fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T31961909 TTH56-63 CJ3 Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 2x4 = 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 2617:06:13 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 3-9-11 3-9-11 Scale = 1:12.4 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.35 BC 0.15 WB 0.00 Matrix-P DEFL. in (loc) Udell L/d Vert(LL) -0.01 2-4 >999 240 Vert(CT) -0.02 2-4 >999 180 Horz(CT) -0.00 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 14 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-11 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=119(LC 12) Max Uplift 3=-87(LC 12), 2=153(LC 12) Max Grav 3=87(LC 1). 2=205(LC 1), 4=72(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vuk=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-8-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 87 lb uplift at joint 3 and 153 lb uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. .loagnin Velez PE No.68182 )BTek Luc. DBA ID11Tek USA FL Cerr 6634 16023 Ssinglet Ridge Rd. C6esred'ield, NO 63017 DAte: October 27,2023 A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek ( a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T31961910 TTH56-63 EJ5 Jack -Open 34 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:14 2023 Page 1 I D:IPuYCeVfQTfYt30 C?ZvfnpzlG U H-RfC?P s B7OHg3N Sg Pqn L8w3u ITXbGK WrC Doi7J 4zJ C?f -1-0-0 5-M 1-0-0 5-0-0 3x4 = 5-0-0 Scale = 1,17.4 Plate Offsets (X,Y)-- [2:0-4-0,0-0-31 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) -0.03 2-4 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.28 Vert(CT) -0.06 2-4 >909 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-P Weight: 18 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=173(LC 12) Max Uplift 3=-137(LC 12), 2=155(LC 12) Max Grav 3=134(LC 17), 2=247(LC 1), 4=96(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-114 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 137 lb uplift at joint 3 and 155 lb uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any This item has been particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joegtdn Velez PE \e.68182 \BTek fur. DBA \BTek USA FL C ert 6634 16023 Sndugley Ridge Rd. Che terfield. \10 63017 Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTPl1 Quality Criteria and SIB-22 available from Truss Plate Institute (wwwLpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961911 TTH56-63 HJ5 Diagonal Hip Girder 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:15 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -1-6-12 7-8-13 1-6-12 7-8-13 3x4 = 7-8-13 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) 0.15 2-4 >603 240 TCDL 7.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.33 2-4 >276 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-SH LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-4-9, 4=Mechanical Max Horz 2=172(LC 8) Max Uplift 3=-180(LC 8), 2=283(LC 8) Max Grav 3=183(LC 1), 2=388(LC 1), 4=148(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:17.2 PLATES GRIP MT20 244/190 Weight: 26 lb FT = 20% Structural wood sheathing directly applied or 6-D-0 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- (9) 1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 180 lb uplift at joint 3 and 283 lb uplift at joint 2. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 104 lb down and 23 lb up at 1-6-10, 85 lb down and 34 lb up at 2-6-11, and 47 lb down and 106 lb up at 4-8-1, and 108 lb down and 95 lb up at 5-1-14 on top chord, and 5 lb down at 1-6-10, 8 lb down at 2-6-11, and 27 lb down at 4-8-1, and 23 lb down at 5-1-14 on bottom chard. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 2-4=-20 Concentrated Loads (lb) Vert: 7=-3(F) 8=-2(B) 11=-5(F) 12=-5(B) This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PF tiu.68182 \BTek 1ec. DBA .1BTek USA FL Cert 6634 16023 Shingle Ridge Rd. Cdeslerflkld, MO 63017 Dare: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not Mffek� a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIRPI1 Quality Criteria and DSB•22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcsoomponenls.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T31961912 TTH56 63 Tot Hip Girder 2 Job Reference (optional) t1Ulldefs rlrstsource ( I ampa, t-L), I ampa, h L - 335154, 6.b3U s Aug sU 2U23 MI I eK industries, Inc. I nu UCt Z6 1 t:Ub:Z1 ZUZ3 vage 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3u ITXbGKWrCDoi7J4zJC?f -�1-0-Q 6-2-0 11-4-12 16-5-6 21-0-0 26-6-10 31-7-4 36-9-10 43-0-0 Q4-0-p i-0 d 6-2 6 5-2 6 5 0 10 5-0.10 5-0-10 5-0-10 5-2-6 1 6-2-6 -0- 5.00 12 7x8 = 3 2x4 11 48 = 7x8 = 48 = 2x4 11 7x8 — 21 22 4 23 24 5 2526 27 6 28 2930 7 31 32 8 33 34 9 Scale = 1:73.6 5x8 = 20 35 36 19 37 38 1817 39 40 16 41 42 1514 43 44 13 45 46 12 5x8 = 2x4 11 5x8 = 7x8 WB = 4x8 = 2x4 11 5x8 = 2x4 11 2x4 I 7x8 WB = 6-2-6 11-4-1 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2020/TP12014 CSI. TC 0.57 BC 0.35 WB 0.72 Matrix-SH DEFL. in Vert(LL) 0.82 Vert(CT) -0.96 Horz(CT) 0.13 (loc) I/defl L/d 16 >625 240 16 >534 180 10 nla n/a PLATES GRIP MT20 244/190 Weight: 531 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 4-4-13 oc purlins. 3-6,6-9: 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 8-1-10 oc bracing. BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=94(LC 7) Max Uplift 2=-1645(LC 8), 10=-1722(LC 8) Max Grav 2=2532(LC 1), 10=2602(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5972/3778, 3-4=-8812/5811, 4-5=-8810/5809, 5-6=-11509/7662, 6-7=-11509/7662, 7-8=-8924/5934, 8-9=8926/5936, 9-10=-6152/3976 BOT CHORD 2-20=-3371/5458, 19-20=-3370/5475, 17-19=-7061/10896, 16-17=-7061/10896, 15-16=-7123/10952, 13-15=7123/10952, 12-13=3553/5641, 10-12=3554/5625 WEBS 3-20=0/450, 3-19=2515/3773, 4-19=-495/505, 5-19=-2340/1584, 5-17=0/383, 5-16=-539/717, 6-16=-447/498, 7-16=454/644, 7-15=0/383, 7-13=-2267/1515, 8-13=-495/505, 9-13=-2451/3705, 9-12=0/449 NOTES- (11) 1) 2-ply truss to be connected together with IOd (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. This Item has been Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. electronically signed and 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to sealed by Velez, Joaquin, PE ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced using a Digital Signature. roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft; L=43ft; eave=5ft; Cat. Printed copies of this 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber document are not considered DOL=1.60 plate grip DOL=1.60 signed and sealed and the 5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific Signature must be Verified to the use of this truss component. 6) Provide adequate drainage to prevent water ponding. On any electronic copies. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Joaquin Velez PE No.69132 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide )BIek 1— DBA NBTek I $A FL C'-t 6634 will fit between the bottom chord and any other members. 16023 Swhigky Ridge Rd. 9 Provide mechanical connection b others of truss to bearing late capable of withstanding 1645 lb uplift at joint 2 and 1722 lb uplift (Y ) 9 P p 9 P 1 P ebe9tereeld. �Jo 63ov Dare: at joint 10. October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. i �� �� Design valid for use only with MiTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961912 TTH56-63 T01 Hip Girder 2 Job Reference (optional) Cunaers Firstbource (I ampa, FL), I ampa, FL - 33064, S.b3U S AUg 3U ZUZ3 mi I eK Industries, Inc. I hu Uct 26 11:06:21 2023 Page 2 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB70Hg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f NOTES- (11) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 158 lb up at 6-2-6, 125 lb down and 153 lb up at 8-3-2, 125 Ib down and 153 lb up at 10-3-2, 124 lb down and 153 lb up at 12-3-2, 124 lb down and 153 lb up at 14-3-2, 124 lb down and 153 lb up at 16-3-2, 124 lb down and 153 Ib up at 18-3-2, 124 lb down and 153 Ib up at 20-3-2, 124 lb down and 153 lb up at 21-6-0, 124 lb down and 153 lb up at 22-8-14, 124 lb down and 153 lb up at 24-8-14, 124 lb down and 153 lb up at 26-8-14, 124 lb down and 153 lb up at 28-8-14, 124 lb down and 153 lb up at 30-8-14, 125 lb down and 153 lb up at 32-8-14, and 125 lb down and 153 lb up at 34-8-14, and 225 lb down and 372 lb up at 36-9-10 on top chord, and 141 lb down at 6-2-6, 56 lb down at 8-3-2, 56 lb down at 10-3-2, 56 lb down at 12-3-2, 56 lb down at 14-3-2, 56 lb down at 16-3-2, 56 lb down at 18-3-2, 56 lb down at 20-3-2, 56 lb down at 21-6-0, 56 Ib down at 22-8-14, 56 Ib down at 24-8-14, 56 lb down at 26-8-14, 56 lb down at 28-8-14, 56 lb down at 30-8-14, 56 lb down at 32-8-14, and 56 Ib down at 34-8-14, and 141 lb down at 36-8-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (ptf) Vert: 1-3=54, 3-9=-54, 9-11=54, 2-10=-20 Concentrated Loads (lb) Vert: 3=-68(B) 9=-167(B) 20=-88(B) 5=-68(B) 17=-28(B) 16=-28(B) 6=-68(B) 15=-28(B) 7=68(B) 12=-88(B) 21=-68(B) 22=68(B) 23=68(B) 24=-68(B) 25=-68(B) 27=-68(B) 28=-68(8) 30=68(131) 31=68(B) 32=-68(B) 33=-68(B) 34=-68(B) 35=28(B) 36=-28(B) 37=-28(B) 38=28(B) 39=28(B) 40=-28(B) 41=-28(B) 42=-28(8) 43=-28(B) 44=-28(B) 45=28(B) 46=-28(B) A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2r2023 BEFORE USE. Design valid for use only with Mi7ek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a thus system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MTek-US.com Job Truss Truss Type Qty Ply T31961913 TTH56-63 T02 Hip 2 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:23 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -i1-0-Q 5-1-7 8-7-3 15-1-10 21F-0 27-10-0 34-4-13 37-10-9 43-0-0 44-0-p 1-049 5-1-7 3-5-12 6-6-7 6 4 G 64-6 6-6-7 3-5 12 5-1-7 -0 3x4 = Sx6 = 5.00 12 3x4 = 4x6 = 3x4 = 5x6 = 4 21 522 23 6 7 24 825 26 9 d Scale = 1:73.6 5x8 = 18 17 16 15 14 13 5x8 = 4x8 = 17-7-10 6x8 = 04 = 4x4 = 6x8 = 08 = 34-4-13 2 Ie 6 Plate Offsets (X,Y)-- [2:0-4-0,Edge], [4:0-3-0,0-2-4] [7:0-3-0,Edge] [9:0-3-0 0-2-4] [11:0-4-0 Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) 0.63 15-16 >811 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.87 15-16 >591 180 BCLL 0.0 Rep Stress Incr YES WB 0.47 Horz(CT) 0.18 11 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 239 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-6-14 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 5-18, 8-13 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=-127(LC 10) Max Uplift 2=-943(LC 12), 11=-943(LC 12) Max Grav 2=1642(LC 1), 11=1642(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3606/2164, 3-4=-3350/1984, 4-5=-3101/1890, 5-6=-4582/2725, 6-8=-4582/2725, 8-9=-3101/1890, 9-10=-3350/1984, 10-11=-3606/2164 BOT CHORD 2-18=-1889/3276, 16-18=-2429/4354, 15-16=-2620/4761, 13-15=2412/4354, 11-13=-1906/3276 WEBS 3-18=-266/323, 4-18=-519/1010, 5-18=1504/893, 5-16=-140/447, 6-16=-291/242, 6-15=-291/242, 8-15=-140/447, 8-13=1504/893, 9-13=-519/1010, 10-13=-266/323 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuK=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 8-7-3, Exterior(2R) 8-7-3 to 14-8-3, Interior(1) 14-8-3 to 34-4-13, Exterior(2R) 34-4-13 to 40-5-12, Interior(1) 40-5-12 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer I Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 11. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagekr \Velez PE Ro.68182 31ITek fur. DBA 3BTek (SA K Cert 6634 16023 Sniugley Ridge Rd. Ckes1erGeld.J10 6301- Dare: October 27,2023 ♦ WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII4473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTeV a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropeMM damage. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrlcation, storage, delivery, erection and bracing of trusses and truss systems, see ANMITI, I Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbesoomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961914 TTH56-63 T03 Hip 2 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06,24 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f I 1-0-' 8-0-9 24-11-7 32-0-0 43-0-0 1-JO 6-10-13 7-0-9 -510oy 6614509 4 6-6-5 0- 5.00 12 5x8 = 421 2x4 11 22 5 23 5x8 = 24 6 25 5x6 = 726 Scale = 1:73.7 3x6 i:�:- 18 17 16 15 14 13 12 11 3x6 2x4 11 3x4 = 4x6 = 3x10 = 2x4 11 5x6 = US = 2x4 II I 6-6-5 11-0-0 18-0-9 24-11-7 32-M 36-5-11 43-0-0 685 4-5 11 7-0 9 6-10-13 7-0-9 + 4-5 11 6-6-5 Plate Offsets (X,Y)—[2:0-3-0,0-1-8],[4:0-5-12,0-2-8],[6:0-3-12,0-3-0],[7:0-3-0,0-2-4],[9:0-3-0,0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.87 Vert(ILL) 0.52 14-15 >988 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.73 14-15 >699 180 BCLL 0.0 Rep Stress Incr YES WB 0.75 Horz(CT) 0.23 9 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 218 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 "Except` TOP CHORD Structural wood sheathing directly applied. 4-6: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 6-15, 6-12 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 9=0-3-8 Max Horz 2=159(LC 11) Max Uplift 2=-943(LC 12), 9=943(LC 12) Max Grav 2=1642(LC 1), 9=1642(LC 1) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3513/2077, 3-4=-3065/1877, 4-5=3608/2259, 5-6=3608/2259, 6-7=-2810/1792, 7-8=-3066/1877, 8-9=-3512/2077 BOT CHORD 2-18=-1794/3166, 17-18=-1794/3166, 15-17=-1479/2792, 14-15=-1949/3605, 12-14=-1949/3603, 11-12=1806/3165, 9-11=-1806/3165 WEBS 3-17=-476/379, 4-17=-161/394, 4-15=577/1078, 5-15=398/374, 6-14=0/281, 6-12=-1058/570, 7-12=-462/882, 8-12=475/379 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vutt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25f ; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 11-0-0, Exterior(2R) 11-0-0 to 17-1-0, Interior(1) 17-1-0 to 32-0-0, Exterior(21R) 32-0-0 to 38-1-0, Interior(1) 38-1-0 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 9. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 )fiiek [oc. DBA 311Tek 1:SA FL Cen 6634 16023 Swiugiec Ridge Rd. C to,,terfi0d, MO 6301- Darr; October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 101II-7473 rev. 1/2/2023 BEFORE USE. ■ Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek' a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TP 1 Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 1 MiTek-US.com Job Truss Truss Type Qty Ply T31961915 TTH56-63 T04 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:26 2023 Page 1 ID: tPuYCeVfQTfYt3OC?ZvfnpzlGUH-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrC Doi7J4zJC?f -1-0-0 7-0-5 13-4-13 18-9-10 24-2-6 29-7-3 35-11-11 43-0-0 44-0-p 7-0-5 64-8 54-13 + 54-13 5-4-13 + 64-8 7-0-5 -0- 5x6 = s nnF15- 3x4 = 5 20 3x4 = 3x6 = 5x6 = 6 7 8 Scale = 1:73.9 3x8 = 18 17 lb 22 2J 10 L4 Zo 14 13 12 3x8 = 2x4 11 7-0-5 134-13 3x8 = 4x6 = 21-0-0 3x4 = 4x6 = 3x8 = 2x4 II 29-7-3 35-11-11 43-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.82 BC 0.80 WB 0.76 Matrix-SH DEFL. in (loc) I/deft Ud Vert(LL) -0.41 15-17 >999 240 Vert(CT) -0.71 15-17 >724 180 Horz(CT) 0.21 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 219 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-6-12 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-191(LC 10) Max Uplift 2=-943(LC 12), 10=943(LC 12) Max Grav 2=1861(LC 17), 10=1861(LC 18) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3963/2094, 3-4=-3216/1782, 4-5=2947/1724, 5-7=-3388/1933, 7-8=2947/1720, 8-9=-3216/1778, 9-10=-3964/2090 BOT CHORD 2-18=-1811/3722, 17-18=-1811/3722, 15-17=-1592/3365, 13-15=-1587/3312, 12-13=-1819/3579, 10-12=1819/3579 WEBS 3-18=0/276, 3-17=7841507, 4-17=-405/963, 5-17=-654/357, 5-15=0/254, 7-15=0/254, 7-13=-654/360, 8-13=-406/963, 9-13=-785/507, 9-12=0/276 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 13-4-13, Exterior(2R) 13-4-13 to 19-5-12, Interior(1) 19-5-12 to 29-7-3, Exterior(2R) 29-7-3 to 35-11-11, Interior(1) 35-11-11 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific electronically signed and to the use of this truss component. sealed by Velez, Joaquin, PE 4) Provide adequate drainage to prevent water ponding. using a Digital Signature. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Printed copies of this will fit between the bottom chord and any other members, with BCDL = 10.Opsf. document are not Considered 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 Ito uplift at joint 2 and 943 lb uplift at signed and sealed and the joint 10. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any signature must be verified particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." on any electronic copies. Joagnln Velez PE Ne.68182 3B7ek Inc. DBA SB7ek USA FL Cerr 6634 16023 Sningl- Ridge Rd. Chesterfield. 110 63017 Dare: October 27,2023 A WARNING-Veriify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1I2r2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not Mffek� a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stabitily and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961916 TTH56-63 T04A Hip 1 1 Job Reference (optional) Builders Firssource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:27 2023 Page 1 I D: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?P s B7OHg3N SgPgn L8w3u ITXbG K WrC Doi7J 4zJC?f 13-4-13 18-9-10 24-2-6 29-7-3 i 35-11-11 43-0-0 7-0-5 6-4-8 5' 5-4-13 5-4-13 6-4-8 7-0-5 5x6 = s nn ls� 3x4 = 19 5 20 3x4 = 3x6 = 6 7 5x6 = 8 Scale = 1:73.8 3x8 = 17 16 " c< — it — co - 12 11 3x8 = 2x4 11 3x8 = 4x6 3x4 = 4x6 = 3x8 = 2x4 11 7-0-5 13-4-13 21-6-0 29-7-3 3rr11-11 43-0-0 7-0-5 6-4-8 8-1-3 8-1-3 6-4-8 7-0-5 Plate Offsets (X,Y)--[2:0-4-2,0-1-81,[4:0-3-0,0-2-41,[8:0-3-0,0-2-4L 10:0-4-2,0-1-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) -0.41 12-14 >999 240 MT20 244/190 TCDL 7.0 Lumber COL 1.25 BC 0.80 Vert(CT) -0.71 12-14 >723 180 BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(CT) 0.21 10 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 217 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-4-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 10=0-3-8, 2=0-3-8 Max Horz 2=190(LC 11) Max Uplift 10=-857(LC 12), 2=944(LC 12) Max Grav 10=1807(LC 18), 2=1861(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3964/2102, 3-4=-3217/1790, 4-5=-2948/1731, 5-7=3390/1945, 7-8=-2951/1723, 8-9=-3220/1794, 9-1 0=-3964/21 00 BOT CHORD 2-17=-1855/3714,16-17=-1855/3714,14-16=-1622/3358,12-14=-1637/3305, 11-12=-1846/3592, 10-11 = 1846/3592 WEBS 3-17=0/276, 3-16=-784/507, 4-16=-405/964, 5-16=-655/358, 5-14=0/255, 7-14=0/253, 7-12=-654/357, 8-12=-416/965, 9-12=793/515, 9-11=0/277 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 13-4-13, Exterior(2R) 13-4-13 to 19-5-12, Interior(1) 19-5-12 to 29-7-3, Exterior(2R) 29-7-3 to 35-11-11, Interior(1) 35-11-11 to 42-10-4 zone; Cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 857 lb uplift at joint 10 and 944 lb uplift at joint 2. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE So.68182 d11Tek 1uc. DBA ABI'ek tSA 1T. Cert.6634 16023 Sniugkv Ridge Rd. Ckesteifieid. \10 63017 Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 112/2023 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see A SVTP 1 Quality Criteria and DSS-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961917 TTH56-63 T05 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:29 2023 Page 1 I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?P s B7OHg3N SgPgn L8w3u ITXbGK WrC Doi7J 4zJC?f -�1-0-q 8-4-4 15-9-10 21-0-0 27-2-6 34-7-12 43-0-0 -0 8-0-0 7-5-5 5-8-6 5-8-6 7-5-5 8-4-4 -0 5.00 12 5x8 = 2x4 11 5x8 = 5 18 6 1920 21 7 Scale = 1:75.2 3x8 = 16 15 G3 14 G4 13 12 3x8 = 2x4 II 5x6 = 3x8 = 5x6 = 2x4 11 15-9-10 21-6-0 27-2-6 34-7-12 43-0-0 M8-0-4 7-5-5 5-8-0 5-8-6 7-5-5 844 n Plate Offsets (X,Y)—[2:0-4-2,0-1-8],[5:0-5-12,0-2-8],[7:0.5-12,0-2-8],[10:0-4-2,0-1-8],[13:0-3-0,0-3-0],[15:0-3-0,0-3-0] LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.97 Vert(LL) 0.36 14 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -0.56 14-15 >920 180 BCLL 0.0 Rep Stress Incr YES WB 0.36 Horz(CT) 0.20 10 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 222 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 `Except' TOP CHORD Structural wood sheathing directly applied. 1-4,8-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-6-5 oc bracing. BOT CHORD 2x4 SP No.1 `Except` WEBS 1 Row at midpt 3-15, 9-13 13-15: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-223(LC 10) Max Uplift 2=-943(LC 12), 10=943(LC 12) Max Grav 2=1861(LC 17), 10=1861(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3888/2047, 3-5=-2973/1686, 5-6=-2882/1743, 6-7=2882/1743, 7-9=2973/1686, 9-10=-3889/2047 BOT CHORD 2-16=-1752/3670, 15-16=-1752/3670, 14-15=-1217/2786, 13-14=-1230/2675, 12-13=-1766/3503, 10-12=1766/3503 WEBS 3-16=0/345, 3-15=-980/593, 5-15=-210/669, 5-14=-198/447, 6-14=-337/305, 7-14=-198/447, 7-13=-210/670, 9-13=-981/593, 9-12=0/345 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) 15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 44-0-0 zone; cantilever left and This item has been right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 electronically signed and plate grip DOL=1.60 sealed by Velez, Joaquin, PE 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific using a Digital Signature. to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. Printed Copies of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. document are not considered 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide signed and sealed and the will fit between the bottom chord and any other members, with BCDL = 10.Opsf. SI g nature must be verified 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 Ito uplift at joint 10. on any electronic copies. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any Jongnin Velez PE \o.68132 particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." SBTek me. DBA SBTek tsA FL Cert 6634 16023 Sniagle} Ridge Rd. Chesterfield. Sip 6301- Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. ■ Design valid for use only with MTek40 connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek"' a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPI1 Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcsmmponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T31961918 TTH56-03 T05A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:31 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3u1TXbGKWrCDoi7J4zJC?f 15-9-10 21-6-0 27-2-6 34-7-12 43-0-0 8-4-4 7-5-5 5-8-6 548-6 7-5-5 844 Scale = 1:75.1 5.00 F12 5x8 = 2x4 11 5x8 = 5 17 6 18 19 20 7 3x8 = 15 14 " 13 LO 12 11 3x8 = 2x4 11 5x6 = 3x8 = 5x6 = 2x4 11 8-4-4 15-9-10 21-6-0 27-2-6 34-7-t2 43-0-0 8-4-4 i 7-5-5 5-8-6 5-8-6 7-5.5 8-0-0 Plate Offsets (X,Y)-- [2:0-4-2,0-1-8], [5:0-5-12,0-2-8], [7:0-5-12,0-2-8], [8:0-0-0,0-0-0], [10:0-4-2,0-1-8], [12:0-3-0,0-3-0], [14:0-3-0,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 1.00 Vert(LL) 0.36 13 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -0.56 12-13 >918 180 BCLL 0.0 * Rep Stress Incr YES WB 0.36 Horz(CT) 0.20 10 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 220 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. 1-4,8-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-4-12 oc bracing. BOT CHORD 2x4 SP No.1 *Except* WEBS 1 Row at midpt 3-14, 9-12 12-14: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=221(LC 11) Max Uplift 2=-944(LC 12), 10=857(LC 12) Max Grav 2=1861(LC 17), 10=1807(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3889/2054, 3-5=-2974/1694, 5-6=-2884/1753, 6-7=-2884/1753, 7-9=-2975/1694, 9-10=-3884/2055 BOT CHORD 2-15=-1797/3663, 14-15=-1797/3663, 13-14=-1261/2779, 12-13=-1249/2675, 11-12=-1791/3514, 10-11=1791/3514 WEBS 3-15=0/345, 3-14=-980/593, 5-14=-209/669, 5-13=-199/448, 6-13=-337/306, 7-13=-196/447, 7-12=-212/672, 9-12=-989/600, 9-11=01346 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuK=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) 15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 42-1D-4 zone; cantilever left and This item has been right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 electronically signed and plate grip DOL=1.60 sealed by Velez, Joaquin, PE 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific using a Digital Signature. to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. Printed copies of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. document are not considered 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide signed and sealed and the will fit between the bottom chord and any other members, with BCDL = 10.Opsf. I Snature must be verified g 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at joint 10. on any electronic copies. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any ..grin V.1- PE 7-68112 particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." %IiT.k le, DBA NDTek USA M C-t 6e34 16023 Sningiey Ridge Rd. C6esfer0eW. -NIO 6301, D.te: October 27,2023 O WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and pproppeMrty damage. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANStol Quality Criteria and DSB-22 available from Truss Plate Institute (www.lpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961919 TTH56-03 T06 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8,630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:32 2023 Page 1 I D:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -1-0-0 6-6-0 12-4-3 18-2-6 24-9-10 30.7-13 36-6-0 43-0-0 -0- 6-6-0 5-10-3 5-10-3 6-7-3 5-10-3 5-10-3 6E-0 - 5.00 12 5x6 = 6 20 5x8 = 721 Scale = 1,75.2 3x8 = io — — it 16 " 15 - co a io 3x8 = 3x4 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 *Except* 14-17: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=-254(LC 10) Max Uplift 2=-943(LC 12), 11=943(LC 12) Max Grav 2=1872(LC 17), 11=1876(LC 18) 4x6 = 3x8 = 3x4 = 4x6 = 3x4 = CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TC 0.84 Vert(LL) -0.4013-15 >999 240 MT20 244/190 BC 0.98 Vert(CT) -0.70 13-15 >733 180 WB 0.99 Horz(CT) 0.20 11 n/a n/a Matrix-SH Weight: 223 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except: 5-8-0 oc bracing: 15-16. WEBS 1 Row at midpt 7-16 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3934/2082, 3-5=-3693/1963, 5-6=-2723/1603, 6-7=-2481/1552, 7-8=-2733/1603, 8-10=-3702/1963, 10-11=-3943/2082 BOT CHORD 2-18=-1800/3760, 16-18=-1470/3172, 15-16=-1093/2484, 13-15=-1483/3010, 11-13=-1813/3578 WEBS 3-18=-333/332, 5-18=-192/687, 5-16=-820/522, 6-16=-296/753, 7-15=-297/836, 8-15=-820/522, 8-13=-192/687, 10-13=-333/332 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 18-2-6, Exterior(2R) 18-2-6 to 24-3-6, Interior(1) 24-3-6 to 24-9-10, Exterior(2R) 24-9-10 to 30-7-13, Interior(1) 30-7-13 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 11. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE \e.68182 )Diek lnc. DBA tBTek USA FL Cert 6634 16023 Sv ingley Ridge Rd. Chesterfield. MO 6301- Date: October 27,2023 ♦ WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek"' a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPl1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T31961920 TTH56-63 T06A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:33 2023 Page 1 I D:tPUYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -1-0-Q 6V 12-4-3 18-2-6 24-9-10 30-7-13 36-6-0 43-0-0 -0- 6�-0 5-10-3 5-10-3 6-7-3 5-10-3 5-10-3 6-6-0 Scale = 1:75.1 Sx6 = 5.00 12 6 19 5x8 = 720 3x8 = it « eo io 15 — 14 w co m is 3x8 = 3x4 = 9-5-2 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 *Except* 13-16: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=253(LC 11) Max Uplift 2=-944(LC 12), 11=-857(LC 12) Max Grav 2=1873(LC 17). 11=1822(LC 18) 4x6 = 3x8 = 3x4 = 4x6 = 3x4 = CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.87 Vert(LL) -0.40 12-14 >999 240 MT20 244/190 BC 0.98 Vert(CT) -0.70 12-14 >734 180 WB 0.99 Horz(CT) 0.20 11 n/a n/a Matrix-SH Weight: 221 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-13 oc purling. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except: 5-7-5 oc bracing: 14-15. WEBS 1 Row at midpt 7-15 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3935/2089, 3-5=-3693/1971, 5-6=2725/1611, 6-7=2483/1560, 7-8=2734/1605, 8-10=-3710/1974, 10-11=-3954/2108 BOT CHORD 2-17=-1844/3753, 15-17=-1514/3165, 14-15=-1112/2483, 12-14=1504/3011, 11-12=-1842/3589 WEBS 3-17=-333/332, 5-17=-192/687, 5-15=820/522, 6-15=-297/754, 7-14=-298/837, 8-14=-823/525, 8-12=-217/693, 10-12=-338/353 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 18-2-6, Exterior(2R) 18-2-6 to 24-3-6, Interior(1) 24-3-6 to 24-9-10, Exterior(2R) 24-9-10 to 30-7-13, Interior(1) 30-7-13 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at joint 11. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jo.gnfu Velez PE N..68182 Nfilek lac. DBA }BTelc CSA Fl. Cerr 6634 16023 SMngloy Rldge Rd. Chesterfield. 1,70 63017 Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery. erection and bracing of trusses and truss systems, see ANSVTPIII Quality Criteria and DSIB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961921 TTH56-63 T07 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:35 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -1-0-Q 7-0-1 13-0-0 19-1-8 23-10-8 30-0-0 35-11-15 43-0-0 4,4-0-p - 7-0-1 5-11-15 6-1-8 4-9-0 6-1-8 5-11-15 7-0-1 -0- dI 0 5x6 = 5.00 F12 5x8 = Scale = 1:75.2 3x8 = io ci — it 16 LJ 15 it — ca io 3x8 — 3x4 = 5x6 WB = 3x8 = 3x4 = 5x6 WB = 3x4 = Ia 0 9-10-15 19-2-9 14-9-0 9-2-9 9-10-15 Plate Offsets (X,Y)--[2:0-4-2,0-1-8],[6:0-3-0,0-2-4],[7:0-5-12,0-2-8],[11:0-4-2,0-1-8] LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in floc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) -0.40 13-15 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -0.70 13-15 >728 180 BCLL 0.0 Rep Stress Incr YES WB 0.41 Horz(CT) 0.17 11 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 228 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 `Except" TOP CHORD Structural wood sheathing directly applied or 2-3-0 oc purlins. 1-4,9-12: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP 2850F 2.0E or 2x4 SP M 31 'Except' WEBS 1 Row at midpt 5-16, 7-16, 8-15 14-17: 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=267(LC 11) Max Uplift 2=-943(LC 12), 11=-943(LC 12) Max Grav 2=1871(LC 17), 11=1873(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3899/2048, 3-5=-3656/1936, 5-6=-2628/1546, 6-7=2388/1500, 7-8=-2631/1546, 8-10=-3661/1936, 10-11=-3905/2048 BOTCHORD 2-18=-1764/3735, 16-18=-1422/3112, 15-16=-1019/2395, 13-15=1434/2951, 11-13=-1776/3539 WEBS 3-18=-351/346, 5-18=-214/750, 5-16=8771557, 6-16=-330/762, 7-15=-326/836, 8-15=-879/558, 8-13=-214/751, 10-13=-351/346 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 19-1-8, Exterior(2E) This item has been 19-1-8 to 23-10-8, Exterior(2R) 23-10-8 to 30-0-0, Interior(1) 30-0-0 to 44-0-0 zone; cantilever left and right exposed ; end vertical left electronically signed and and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 sealed by Velez, Joaquin, PE 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific Digital Signature. to the use of this truss component. using a 4) Provide adequate drainage to prevent water ponding. Printed copies Of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. document are not considered 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide signed and sealed and the will fit between the bottom chord and any other members, with BCDL = 10.Opsf. signature must be verified 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 11. on any electronic copies. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any 3oagnkr l'elez PE \u.68182 particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." MiTek Luc. DBA MiTek USA FL Cert 6634 16023 Svriagley Ridge Rd. C4e+lerfield, MO 63011 Datr. October 27,2023 a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/7/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTeV a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropertrtyy damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS61 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T31961922 TTH56-03 T07A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:36 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 0-p 7 0 1 13-0-0 19-1-8 23-10-8 30-0-0 35-11-15 43-0-0 -0- 7-0-t 5-11-15 6-1-8 4-9-0 6-1-8 5-11-15 7-0-1 5x6 = 5.00 F12 5x8 = Scale = 1:75.1 3x8 = I 1. — 15 " 14 w co 41 — 3x8 = 3x4 = 5x6 WB = 3x8 = 3x4 = 5x6 WB = 3x4 = 9-10-15 9-2-9 4-9-0 9-2-9 9-10-15 Plate Offsets (X,Y)--[2:0-4-2,0-1-8],[6:0-3-0,0-2-4],[7:0-5-12,0-2-8],[11:0-4-2,0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) -0.40 12-14 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vertil -0.70 12-14 >729 180 BCLL 0.0 Rep Stress Incr YES W I 0.41 Horz(CT) 0.17 11 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 227 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 `Except` TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. 1-4,9-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP 2850F 2.0E or 2x4 SP M 31 'Except" WEBS 1 Row at midpt 5-15, 7-15, 8-14 13-16: 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=265(LC 11) Max Uplift 2=-944(LC 12), 11=-857(LC 12) Max Grav 2=1871(LC 17), 11=1819(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3900/2055, 3-5=-3656/1944, 5-6=-2629/1554, 6-7=2389/1507, 7-8=-2633/1549, 8-10=-3669/1950,10-11=-3914/2074 BOT CHORD 2-17=-1808/3727, 15-17=-1466/3104, 14-15=-1038/2387, 12-14=-1455/2952, 11-12=-1805/3550 WEBS 3-17=-351/346, 5-17=-214/750, 5-15=-877/557, 6-15=-331/763, 7-14=-327/837, 8-14=-881/560, 8-12=-238/757, 10-12=354/365 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 19-1-8, Exterior(2E) This item has been 19-1-8 to 23-10-8, Exterior(21R) 23-10-8 to 30-0-0, Interior(1) 30-0-0 to 42-10-4 zone; cantilever left and right exposed ; end vertical electronically signed and left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 sealed by Velez, Joaquin, PE 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific using a Digital Signature. to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. Printed copies of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. document are not considered 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide signed and sealed and the will fit between the bottom chord and any other members, with BCDL = 10.Opsf. signature must be verified 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at joint 11. on any electronic copies. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any .reegam V.1- PE No,68182 particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." 31irek 1mr. DDA.WTek f SA Ft. C-( 6634 16023 Swimgiey Ridge Rd. Ch-t-field, T'IQ 6M17 Date; October 27,2023 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTeV a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and pproperty damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponenls.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961923 TTH56-63 T09 Common Supported Gable 14 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:38 2023 Page 1 I D:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-RfC?PsB70Hg3NSgPgnL8w3uITXbGKWrCDci7J4zJC?f -�1-0-Q 21-6-0 43-0-0 -0- 21-6-0 21-6-0 Scale = 1:73.0 5x6 = 5.00 12 13 14 I� 3x6 = 3x6 = 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 3x6 = 3x6 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.17 Vert(LL) -0.00 1 n/r 120 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.18 Vert(CT) 0.00 1 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(CT) 0.01 24 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 271 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 WEBS 1 Row at midpt 13-35, 12-36, 14-34 REACTIONS. All bearings 43-0-0. (lb) - Max Horz 2=297(LC 11) Max Uplift All uplift 100 Ib or less at joint(s) 2, 36, 39, 40, 41, 42, 44, 34, 31, 30, 29, 28, 26, 24 except 37=-104(LC 12), 43=-104(LC 12), 45=153(LC 12), 33=-104(LC 12), 27=-107(LC 12), 25-179(LC 12) Max Grav All reactions 250 lb or less at joint(s) 2, 35, 36, 37, 39, 40, 41, 42, 43, 44, 34, 33, 31, 30, 29, 28, 27, 26, 24 except 45=258(LC 17), 25=271(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All farces 250 (lb) or less except when shown. TOP CHORD 9-10=-113/307, 10-11=-128/376, 11-12=-152/448, 12-13=176/512, 13-14=176/512, 14-15=-152/448, 15-16=-128/376, 16-17=104/307 WEBS 3-45=-180/332, 23-25=-186/377 NOTES- (12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=2ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3E) -1-0-0 to 3-6-0, Exterior(2N) 3-6-0 to 21-6-0, Comer(3R) 21-6-0 to 25-9-10, Exterior(2N) 25-9-10 to 43-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind (cads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANS11TPI 1. 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific This item has been to the use of this truss component. electronically signed and 5) All plates are 2x4 MT20 unless otherwise indicated. sealed by Velez, Joaquin, PE 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. using a Digital Signature. 8) This truss has been designed for a 10.0 psf bottom chord live Iliad nonconcurrent with any other live loads. Printed Copies of this 9) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide document are not considered will fit between the bottom chord and any other members. Signed and Sea led and the 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at 2, 36, 39, 40, 41, l signature nature must e verified 42, 44, 34, 31, 30, 29, 28, 26, 24 except (jt=lb) 37=104, 43=104, 45=153, 33=104, 27=107, 25=179. 11) Beveled plate or shim required to provide full bearing surface with truss chord atjoint(s) 24. on any electronic copies. 12) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any Jo.quin Velez PE No.68182 particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." ?Biek luc. DBA MMIlk CSA FL Cett 6634 16023 Ssvtngle) Ridge Rd. Chesterfield. ]10 63017 Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 rev. 1/212023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based onty upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicabifity of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and pproperrtyly damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrP I Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314,434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961924 TTH56-63 T10 Common 32 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:39 2023 Page 1 I D: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?P s B7OH q3N Sg Pqn L8w3u ITXbGK WrC Doi7 J4zJ C?f -1-0-Q 7-7-3 14-6-10 21-6-0 28-5-6 35-4-13 43-0-0 44-0-Q 7-7-3 6-11-6 6-11-6 6-11-6 6-11-6 7-7-3 -0- �t d 5x6 = 5.00 F12 Scale = 1:72.2 3x8 = „ ,. -- <+ 11 — - 4o <r .1 3x8 = 3x4 = 4x6 = 3x4 = 3x4 = 4x6 = 3x4 = 9-0-6 17-3-15 25-8-1 33-11-10 43-0-0 9.0-6 ' 8-3-10 8-0-1 8-3-10 9-0-6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) -0.40 14-15 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(CT) -0.68 14-15 >751 180 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(CT) 0.18 10 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 'Except' 1-4,8-11: 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=298(LC 11) Max Uplift 2=-943(LC 12), 10=943(LC 12) Max Grav 2=1885(LC 17), 10=1885(LC 18) PLATES GRIP MT20 244/190 Weight: 218 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3931/2002, 3-5=-3802/2010, 5-6=-2890/1661, 6-7=2890/1661, 7-9=-3802/2010, 9-10=-3932/2002 BOT CHORD 2-17=-1708/3783, 15-17=-1306/3020, 14-15=-850/2218, 12-14=-1307/2872, 10-12=-1708/3560 WEBS 6-14=-520/1153, 7-14=-763/574, 7-12=392/909, 9-112=362/365, 6-15=-520/1153, 5-15=-763/574, 5-17=-392/908, 3-17=-362/365 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) 21-6-0 to 25-9-10, Interior(1) 25-9-10 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb) 2=943, 10=943. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Josgahr Velez PE \o.69182 12ITek 1uc. DBA AhTek USA FL Ccrt 6634 16023 Swiux ec Ridge Rd. Chesterfield. \20 63017 Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2r2023 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek"' a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTr i Quality Criteria and SIB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 .and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T31961925 TTH56-63 T10A COMMON 16 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:41 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB70Hg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC.7f 7-7-3 14-6-10 216-0 28-5-6i 354-13 43-M 7-7-3 6-11-6 6-11� 6-11-6 6-11-6 7-7-3 0 0 5x6 = 5.00 12 Scale = 1:72.2 3x8 = — -,-. 1. 11 � � 11 11 I I 3x8 = 3x4 = 4x6 = 3x4 = 3x4 = 4x6 = 3x4 = Ia 0 Plate Offsets (X,Y)— [2:0-4-2,0-1-8], [4:0-3-0,Edge], [8:0-3-0,Edge], [10:0-4-2,0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) -0.40 13-14 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -0.68 13-14 >750 180 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(CT) 0.18 10 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 216 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 'Except' TOP CHORD Structural wood sheathing directly applied. 1-4,8-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=297(LC 11) Max Uplift 2=-944(LC 12), 10=-857(LC 12) Max Grav 2=1886(LC 17), 10=1831(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3932/2003, 3-5=-3803/2012, 5-6=-2892/1662, 6-7=-2892/1671, 7-9=-3811/2048, 9-10=3941/2041 BOT CHORD 2-16=-1752/3776, 14-16=-1350/3012, 13-14=-893/2210, 11-13=-132712872, 10-11=-1768/3571 WEBS 6-13=-521/1155, 7-13=-766/577, 7-11=422/916, 9-11=-365/381, 6-14=-520/1153, 5-14=-763/574, 5-16=-391/908, 3-16=362/365 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuK=150mph (3-second gust) Vasd=116mph, TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) 21-6-0 to 25-9-10, Interior(1) 25-9-10 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific electronically signed and to the use of this truss component. sealed by Velez, Joaquin, PE 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for using a Digital Signature. a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. Printed copies of this 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) document are not considered 2=944,10=857. "This signed and sealed and the 7) manufactured product is designed as an individual building component. The suitability and use of this component for any signature must be verified particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." on any electronic copies. Joaquin Celez FE N..68182 J11Tek Luc. DBA kHTek USA FL Cer 6634 16023 Swingley Ridge Rd. Chesterfield, VIO 63017 Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1l2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek' a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and proppetrtrtyy damage. For general gguidance regarding the 16023 Swingley Ridge Rd. '.. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T31961926 TTH56-63 T11 Common 8 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:42 2023 Page 1 I D:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -�1-0-Q 7-7-3 14�-10 21-6-0 28-5-6 35-4-13 43-0-0 45-0-0 -0- 7-7-3 6-11-6 6-11-6 6-11-6 6-11-6 7-7-3 2-0-0 5.00 12 5x6 = Scale = 1:73.7 114 3x4 = 4x6 = 94)-6 3x4 = 3x4 = 4x6 = 33-11-10 3x4 = 43-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.91 BC 0.92 WB 0.99 Matrix-SH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl Ud -0.40 14-15 >999 240 -0.68 14-15 >755 180 0.18 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 220 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 'Except` TOP CHORD Structural wood sheathing directly applied. 1-4,8-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-310(LC 10) Max Uplift 2=-939(LC 12), 10=-1020(LC 12) Max Grav 2=1885(LC 17), 10=1934(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3930/1998, 3-5=-3800/2006, 5-6=2887/1656, 6-7=2886/1647, 7-9=3779/1968, 9-10=-3921/1959 BOTCHORD 2-17=-1668/3790, 15-17=-1252/3027, 14-15=-827/2225, 12-14=-1281/2868, 10-12=-1668/3535 WEBS 6-14=-516/1150, 7-14=-758/569, 7-12=359/890, 9-12=354/345, 6-15=-519/1153, 5-15=-763/575, 5-17=-392/908, 3-17=362/365 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) 21-6-0 to 25-9-10, Interior(1) 25-9-10 to 45-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific electronically signed and to the use of this truss component. sealed by Velez, Joaquin, PE 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' using a Digital Signature. 5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. Printed copies of this 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) document are not considered 2=939,10=1020. "This signed and sealed and the 7) manufactured product is designed as an individual building component. The suitability and use of this component for any signature nature must be verified particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." on any electronic copies. .foagain Velez PE \0.68182 \BTek Luc. DBA Yfflek USA PT. Cen 4634 16023 Siciugley Ridge Rd. Chesterfield. MO 63017 Dale: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not Mffek� a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see A SVTPIII Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961927 TTH56-63 Vol GABLE 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 5-6-8 2x4 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:43 2023 Page 1 I D:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-RfC?PsB7OHg3N SgPgnL8w3ulTXbGKMCDoi7J4zJC?f 11-1-0 4x4 = 2x4 11 2x4 11 2x4 11 2x4 Scale = 1:17.8 •d 0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TP12014 CSI. TC 0.17 BC 0.13 WB 0.11 Matrix-SH DEFL. in floc) I/deft Ud Vert(LL) n/a n/a 999 Vert(CT) n/a n/a 999 Horz(CT) 0.00 5 n/a n/a PLATES GRIP MT20 244/190 Weight: 38 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 11-1-0. (lb) - Max Horz 1=55(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 8=-184(LC 12), 6=184(1_C 12) Max Grav All reactions 250 Ito or less at joint(s) 1, 5, 7 except 8=279(LC 1), 6=279(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-187/368, 4-6=187/368 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuK=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=301t; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 5-6-8, Exterior(2R) 5-6-8 to 8-6-8, Interior(1) 8-6-8 to 10-3-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except This item has been (jt=lb) 8=184, 6=184. electronically signed and 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 1-riahr Velez PE N0.68181 \BTek lea. DBA S1lTek ('SA FL CCen 6634 16023 Soiuglec Ridge Rd. ChrslrrGeld. N10 63017 Darr: October 27,2023 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 11212023 BEFORE USE. ■ Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropertrtyy damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIlTrl1 Qual Criteria and guidance available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961928 TTH56-63 V02 valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 4-0-0 3x4 i 2x4 II 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:44 2023 Page 1 I D: tP uYCeVfQTfYt30 C?ZvfnpzlG U H-RfC?PsB70 H q3N Sg Pqn L8w3u ITXbG KWrC Doi? J 4zJC?f 8-0-0 4x4 = 3x4 Scale = 1:14.6 .o d 7-11-6 8-pro 7-11-6 0- -10 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.27 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 24 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=7-10-13, 3=7-10-13, 4=7-10-13 Max Horz 1=37(LC11) Max Uplift 1=-64(LC 12), 3=64(LC 12), 4=-133(LC 12) Max Grav 1=107(LC 21), 3=107(LC 22), 4=273(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-169/308 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=lb) 4=133. This item has been 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any electronically signed and particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagaia Velez PE Na.68182 3BTek lac. DBA NUTek t:SA FL Cen 6634 16023 Swiaglep Ridge Rd. Chesterfield. \40 63017 Date: October 27,2023 ,& WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1l2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not Mffek�r a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP 1 Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961929 TTH56-63 V03 Valley 2 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:45 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 3x6 = Scale = 1:7.6 5.00 F12 2 3 1 2x4 :::� 2x4 ' 4-M Plate Offsets (X,Y)— [2:0-3-0,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.12 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020frPI2014 Matrix-P Weight: 10 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-0-0, 3=4-0-0 Max Horz 1=-14(LC 10) Max Uplift 1=-50(LC 12), 3=-50(LC 12) Max Grav 1=92(LC 1), 3=92(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE N..68182 MiTek Inc DBA .All USA FL Cen 6634 16023 Sssiugi.y Ridge Rd. Chesterfield, MO 63011 Date: October 27,2023 A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek' a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrr 1 Oual ty Criteria and 4 B-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T31961930 TTH56Fi3 VO4 GABLE 1 1 �JcibRf.rence (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:46 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB70Hg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 2-1-8 4-3-0 2x4 - 2x4 Plate Offsets (X,Y)— [2:0-3-0,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 11 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-3-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-3-0, 3=4-3-0 Max Horz 1=-16(LC 10) Max Uplift 1=-55(LC 12), 3=-55(LC 12) Max Grav 1=101(LC 1), 3=101(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) 1, 3. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Yelez PE To.68182 \BTek Luc. DBA 3BTek USA FL Cen 6634 16023 S�iugj.y Ridge Rd. Cb-ferGetdJ10 63017 Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. w Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek' a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see A SUTPI1 Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961931 TTH56-03 V05 GABLE 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 4-6-8 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:47 2023 Page 1 I D:tPUYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 9-1-0 Scale = 1:16.7 4x4 = 8 7 6 2x4 2x4 11 2x4 11 2x4 11 2x4 9-1-0 9-1-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.10 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.08 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 5 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-SH Weight: 30 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 9-1-0. (lb) - Max Horz 1=-43(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=127(1-C 12), 6=-127(LC 12) Max Grav All reactions 250 lb or less atjoint(s) 1, 5, 7, 8, 6 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. WEBS 2-8=-142/301, 4-6=142/301 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuK=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-6-8, Exterior(2R) 4-6-8 to 7-6-8, Interior(1) 7-6-8 to 8-3-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) a This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except Ot=lb) This item has been 8=127, 6=127. electronically signed and 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jooquin Vel- PE \e.68182 )t17ek 1— DBA }DTek USA FL Cen 6634 16023 Soiuglec Ridge Rd. Cdeeler6eld. 3JO 6301-, Date: October 27,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek* a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPI1 Quality Criteria and USB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbescomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T31961932 TTH56-63 V06 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, v a 0 2x4 2-6-8 5.00 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:48 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-RfC?PsB70Hg3NSgPgnL8w3u ITXbGKWrCDoi7J4zJC?f 5-1-0 3x6 = 2x4 Scale = 1:9.8 0-Q-10 5-1-0 0- - 0 5-0-6 Plate Offsets (X Y)-- [2:0-3-0,Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.15 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.26 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight: 13 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-11-13, 3=4-11-13 Max Horz 1=-21(LC 10) Max Uplift 1=-72(LC 12), 3=-72(LC 12) Max Grav 1=132(LC 1), 3=132(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-148/287, 2-3=148/299 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ff; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any This item has been particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE \e.68132 NBTek l— DBA VBTek CSA Fl.Cen 6634 16023 Swingiey Ridge Rd. Cheaterlleld. MO 63017 Date: October 27,2023 O WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 11212023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" 7Rd. a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swinglfabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPl1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpmst.org) Chesterfieldand BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200/ Job Truss Truss Type Qty Ply T31961933 TTH56-63 V07 GABLE 1 1 Job Reference (optional) Builders FirstSouroe (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 2617:06:49 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f 04 = Scale = 1:24.4 1 6 6 3x4 16 15 14 13 12 11 10 3x4 14-7-8 14-7-8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(ILL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.08 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.00 9 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 64 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 14-7-8. (lb)- Max Horz 1=112(LC11) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 14, 15, 12, 11 except 16=146(LC 12), 10=146(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 9, 13, 14, 15, 16, 12, 11, 10 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 7-3-12, Exterior(2R) 7-3-12 to 10-3-12, Interior(1) 10-3-12 to 13-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 14, 15, 12, This item has been 11 except (jt=lb) 16=1 46, 1 0=1 46. electronically signed and 9) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 3--hilt Velez PE "..68182 lhiek for, DBA DTek USA FL Celt 4634 16023 Saingley Ridge Rd. Chesterfield. M0 63017 Date: October 27.2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek* a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damagge. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSM11 Quakty Criteria and OSB-22 available from Truss Plate Institute (www.tpinsLorg) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314,434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T31961934 TTH56-63 V08 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, a 0 d 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:50 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrC Doi7J4zJC?f 11-3-8 5-7-12 Scale = 1:20.1 4x6 = 4 4x4 - 2x4 11 4x4 11-3-0 0-6-8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-SH Weight: 37 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=11-2-8, 3=11-2-8, 4=11-2-8 Max Horz 1=-84(LC 10) Max Uplift 1=-104(LC 12), 3=104(LC 12), 4=-196(LC 12) Max Grav 1=169(LC 21), 3=169(LC 22), 4=411(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-251/355 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 5-7-12, Exterior(2R) 5-7-12 to 8-7-12, Interior(1) 8-7-12 to 10-7-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) This item has been 1=104, 3=104, 4=196. electronically signed and 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE \u.68182 \Biek 1ua. DBA Vll7ek USA FL C ert 6634 1602.1 S�iagiey Ridge Rd. Chesterfnetd, MO 63017 Date: October 27,2023 A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. ■ Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek"' a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and pproppeeMrty damage. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSl7TA Quality Criteria and DS8.22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T31961935 TTH56-03 V09 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 3-11-12 3x4 2x4 II 8.630 s Aug 3020Z3.MiTek Industries, Inc. Thu Oct 26 17:06:51 2023 Page 1 I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?P sB70H q3N Sg PgnL8w3u ITXbG KWrC Doi7J4zJ C?f 7-11-8 4x4 = 3x4 Scale = 1,14.6 .9 d 7-11-0 0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.32 Vert(CT) n/a n/a 999 BCLL 0.0 * Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 25 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=7-10-8, 3=7-10-8, 4=7-10-8 Max Horz 1=56(LC 11) Max Uplift 1=-69(LC 12), 3=69(LC 12), 4=-131(LC 12) Max Grav 1=113(LC 21), 3=113(LC 22), 4=275(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-167/293 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 3-11-12, Exterior(2R) 3-11-12 to 6-11-12, Interior(1) 6-11-12 to 7-3-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except Qt=lb) This item has been 4=131. electronically signed and 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. .r-qukr VA.. PE Fe.68182 31iTek tat. DBA 1ItTek l-SA FL Cen 6634 16023 Snhii } Ridge Rd. Chesterfield. S30 63017 Date: October 27,2023 ♦ WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 14II-7473 rev. 1/7/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T31961936 TTH56-63 V10 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 2-3-12 2x4 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 2617:06:52 2023 Page 1 I D: tP uYC eVfQTfYt3OC?ZvfnpzlGU H-RfC?P sB7OH q3N Sg Pqn L8w3u ITXbG K WrC Doi7J4zJ C?f 3x6 = 2 2x4 Scale = 1:8.6 a ro 0 0- -8 4-7-0 Plate Offsets (X Y)-- [2:0-3-0 Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.23 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight: 12 Ito FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-6-8, 3=4-6-8 Max Horz 1=-28(LC 10) Max Uplift 1=-68(LC 12), 3=68(1_C 12) Max Grav 1=125(LC 1), 3=125(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ;end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jeaqufu Velez PE No.68182 )iTek Luc. DBA NUT& (:SA FL C'ert 6634 16023 Sviugley Ridge Rd. Che #t ,&Id. MO 63017 Dal,: October 27,2023 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the appticability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property dame9ge. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Quality For and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbescomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply ]Job T31961937 TTH56-63 V11 Valley 1 1 Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:53 2023 Page 1 I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3NSgPgn L8w3u ITXbGKWrC Doi7J 4zJC?f 7-8-0 Scale = 1:14.2 4x4 = 3x4 � 2x4 II 3x4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.15 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 23 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=7-8-0, 3=7-8-0, 4=7-8-0 Max Horz 1=-35(LC 10) Max Uplift 1=-60(LC 12), 3=60(LC 12), 4=-127(LC 12) Max Grav 1=102(LC 21), 3=102(LC 22), 4=258(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-4=-159/296 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift atjoint(s) 1, 3 except Qt=lb) 4=127. This item has been 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any electronically signed and particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 1—I.in Velez PE No.68182 Alfektut. DBA lffek USA F7.Cer16634 16023 Swngley Ridge Rd. Ciexierfieid, Mo 63017 Date: October 27.2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. ■ Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Stmetural Building Component Association (www.sbcsmmponents.com) 314.434.1200 / MTek-US.com Symbols Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION 1/2 L Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. _f�Apply plates to both sides of truss and fully embed teeth. 0-11fi r - -I- For 4 x 2 orientation, locate plates 0- ''+6' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. " Plate location details available in MiTek software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number/letter where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-22: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 3 Joint ID by TOP CHORDS C1-2 C2-3 WEBS Ac,4O a2 U Oc7-6 c6-7 ce-6 BOTTOM CHORDS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. Product Code Approvals ]CC -ES Reports: ESR-1988, ESR-2362, ESR-2685, ESR-3282 ESR-4722, ESL-1388 Design General Notes Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2023 MiTek® All Rights Reserved MiTekW MiTek Engineering Reference Sheet: MII-7473 rev. 1/2/2023 Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19 % at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21. The design does not take into account any dynamic or other loads other than those expressly stated. t 5 �BoWecaseaW [tkCIN [ FDW 6VkU U s Double 16" BCI® 4500s-1.8 PASSED ��// 1st Floor\Floor Joists\FJ1(i1553) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ 1(i1553) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: B1 19-05-12 Total Horizontal Product Length = 19-05-12 B2 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B 1, 2-3/8" 854 / 0 213 / 0 B2, 2-3/8" 1122 / 0 280 / 0 Load Summary Live Dead Snow Wind Roof OCS Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-00-00 19-05-12 Top 41 10 n\a View Fill) 2 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-00-00 15-10-10 Top 39 10 n\a View Fill) 3 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 16-00-06 19-05-12 Top 41 10 n\a View Fill) 4 FJ2(i1526) Conc. Pt. (Ibs) L 15-10-10 15-10-10 Top 417 104 n\a Hole Summary Description Center Elevation Ref. Height Width Shape Orientation H01 08-00-00 8" L 12" Circular Horizontal H02 12-00-00 8" L 12" Circular Horizontal Controls Summary Value %Allowable Duration Case Location Pos. Moment 5551 ft-Ibs 67.9% 100% 1 10-07-14 End Reaction 1402 Ibs 59.4% 100% 1 19-05-12 End Shear 1382 Ibs 35.0% 100% 1 19-03-06 Hole #1 Shear 396 Ibs 36.1 % 100% 3 08-00-00 Hole #2 Shear 320 Ibs 29.1 % 100% 4 12-00-00 Total Load Deflection L/694 (0.332") 34.6% n\a 1 10-00-00 Live Load Deflection L/868 (0.266") 55.3% n\a 6 10-00-00 Max Defl. 0.332" 33.2% n\a 1 10-00-00 Span / Depth 14.4 Hole Location Valid % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 2-3/8" x 3-1/2" 1067 Ibs 14.7% 45.2% Unspecified B2 Wall/Plate 2-3/8" x 3-1/2" 1402 Ibs 19.3% 59.4% Unspecified Cautions Distributed side -load and/or concentrated side loads exceeds allowable magnitude for connection design. Please consult a technical representative or Professional Engineer for the design of the connection. All multiple member 16" BCI® 4500s-1.8 applications with side load or unevenly distributed top load require filler blocks and fasteners. See Boise Cascade Technical Note IJ-13 for further information. Page 1 of 9 Boise cascade Double 16" BCI® 4500s-1.8 PASSED F'I�:Ir1FLRED'.vGLb PR9GU���S BC Design Engine Member Report Build 8548 Job name: Address: City, State, Zip: Customer: Code reports: ESR-1336 Notes 1st Floor\Floor JoistslFJ1(il553) (Floor Joist) Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 File name: TTH1-9.mmdl Description: 1st Floor\Floor Joists\FJ1(i1553) Specifier: Designer: Company: Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJST"1, ALLJOIST®, BC RIM BOARDTm, BCI® , BOISE GLULAMTM, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, Page 2 of 9 Emse cascacw— Double 16" BCI® 4500s-1.8 PASSED enc +�r +eu wxo aar:oucr; 1 st Floor\Floor JoistsT.12(i1526) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ2(i1526) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: W B 04-04-0s B1 Total Horizontal Product Length = 04-04-08 B2 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1, 2" 422/0 106/0 B2, 4" 871 / 0 218 / 0 Load Summary Live Dead Snow Wind Roof OCS Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FJ5(i1545) Conc. Pt. (Ibs) L 01-09-10 01-09-10 Top 635 159 n\a 2 FJ5(i1533) Conc. Pt. (Ibs) L 03-09-10 03-09-10 Top 648 162 n\a Controls Summary Value %Allowable Duration Case Location Pos. Moment 885 ft-Ibs 10.8% 100% 1 01-09-10 End Reaction 1089 Ibs 36.9% 100% 1 04-04-08 End Shear 1089 Ibs 27.6% 100% 1 04-00-08 Total Load Deflection L/999 (0.006") n\a n\a 1 01-09-10 Live Load Deflection L/999 (0.005") n\a n\a 2 01-09-10 Max Defl. 0.006" n\a n\a 1 01-09-10 Span / Depth 3.0 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Hanger 2" x 3-1/2" 528 Ibs 31.7% 18.3% IUS3.56/16 B2 Wall/Plate 4" x 3-1/2" 1089 Ibs 8.9% 36.9% Unspecified Cautions Hanger IUS3.56/16 requires (14) 10d face nails, (2) 10dx1.5 joist nails. Distributed side -load and/or concentrated side loads exceeds allowable magnitude for connection design. Please consult a technical representative or Professional Engineer for the design of the connection. All multiple member 16" BCI® 4500s-1.8 applications with side load or unevenly distributed top load require filler blocks and fasteners. See Boise Cascade Technical Note IJ-13 for further information. Web stiffeners (WSb) are required depending upon actual reaction, hanger type, or other web stiffener requirement at bearing(s) B1. Header for the hanger IUS3.56/16 is a Double 16" 1-joist. Page 3 of 9 Boise cascacw � 11INE[�tQp Double 16" BCI® 4500s-1.8 PASSED c WX?0 06UG15 1st FloorlFloor JoistslFJ2(i1526) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1 st Floor\Floor Joists\FJ2(i1526) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Hanger Manufacturer: Simpson Strong -Tie, Inc. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTM', ALLJOIST®, BC RIM BOARD-, BCI® , BOISE GLULAMM, BC FloorValueO , VERSA -LAM®, VERSA -RIM PLUS®, Page 4 of 9 Boise cascade' = Single 16" BCI® 6000s-1.8 PASSED 1 st Floor\Floor Joists\FJ3(i1548) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ3(i1548) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: B1 19-05-12 Total Horizontal Product Length = 19-05-12 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1, 2-3/8" 779 / 0 195 / 0 B2, 2-3/8" 779 / 0 195 / 0 B2 Load Summary Live Dead Snow Wind Roof OCS Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FC3 Floor Decking (Plan Unf. Lin. (Ib/ft) L 00-00-00 19-05-12 Top 80 20 n\a View Fill) Hole Summary Description Center Elevation Ref. Height Width Shape Orientation H01 08-00-00 8" L 12" Circular Horizontal H02 12-00-00 8" L 12" Circular Horizontal Controls Summary Value %Allowable Duration Case Location Pos. Moment 4612 ft-Ibs 83.9% 100% 1 09-08-10 End Reaction 974 Ibs 72.7% 100% 1 00-00-00 End Shear 954 Ibs 43.9% 100% 1 00-02-06 Hole #1 Shear 303 Ibs 50.1 % 100% 3 08-00-00 Hole #2 Shear 338 Ibs 56.0% 100% 4 12-00-00 Total Load Deflection U587 (0.393") 40.9% n\a 1 09-08-10 Live Load Deflection L/734 (0.314") 65.4% n\a 6 09-08-10 Max Defl. 0.393" 39.3% n\a 1 09-08-10 Span / Depth 14.4 Hole Location Valid % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 2-3/8" x 2-5/16" 974 Ibs 20.3% 72.7% Unspecified B2 Wall/Plate 2-3/8" x 2-5/16" 974 Ibs 20.3% 72.7% Unspecified Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALCO analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCO, BC FRAMER@ , AJSTm, ALLJOISTO , BC RIM BOARDTM, BCI@ , BOISE GLULAMM, BC FloorValue@ , VERSA -LAM@, VERSA -RIM PLUSO , Page 5 of 9 Boisecascade = Single 16" BCI® 6000s-1.8 PASSED _IGikECrlEfJ 4HQ Jl� GPf,{J��i$ 1 st Floor\Floor JoistslFJ4(11527) (Floor Joist) BC Design Engine Member Report Dry 12 spans I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1 st Floor\Floor Joists\FJ4(i1527) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: 11-04-02 08.01-10 B1 B2 B3 Total Horizontal Product Length = 19-05-12 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1, 2-3/8" 403 / 20 96 / 0 B2, 3-1/2" 951 / 0 238 / 0 B3, 2-3/8" 302 / 78 56 / 0 Load Summary Live Dead Snow Wind Roof OCS Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-00-00 19-05-12 Top 80 20 n\a View Fill) Hole Summary Description Center Elevation Ref. Height Width Shape Orientation H01 08-00-00 8" L 12" Circular Horizontal H02 14-00-00 8" L 12" Circular Horizontal Controls Summary Value %Allowable Duration Case Location Pos. Moment 1179 ft-Ibs 21.5% 100% 2 04-11-13 Neg. Moment -1066 ft-Ibs 19.4% 100% 1 11-04-02 End Reaction 499 Ibs 37.3% 100% 2 00-00-00 Int. Reaction 1189 Ibs 44.9% 100% 1 11-04-02 End Shear 479 Ibs 22.0% 100% 2 00-02-06 Cont. Shear 641 Ibs 29.5% 100% 1 11-02-06 Hole #1 Shear 326 Ibs 54.0% 100% 4 08-00-00 Hole #2 Shear 268 Ibs 44.3% 100% 1 14-00-00 Total Load Deflection L/999 (0.043") n\a n\a 2 05-06-08 Live Load Deflection L/999 (0.035") n\a n\a 9 05-06-08 Total Neg. Defl. L/999 (-0.003") n\a n\a 2 14-01-08 Max Defl. 0.043" n\a n\a 2 05-06-08 Span / Depth 8.4 Hole Location Valid % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 2-3/8" x 2-5/16" 499 Ibs 10.4% 37.3% Unspecified B2 Wall/Plate 3-1/2" x 2-5/16" 1189 Ibs 16.8% 44.9% Unspecified B3 Wall/Plate 2-3/8" x 2-5/16" 358 Ibs 7.5% 26.8% Unspecified Page 6 of 9 BoisecascacW Single 16" BCI® 6000s-1.8 PASSED enneero wcu>o:,aonuc.rs 1 st Floor\Floor Joists\FJ4(il527) (Floor Joist) BC Design Engine Member Report Dry 12 spans I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ4(i1527) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75) Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALCO analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTm, ALLJOIST®, BC RIM BOARD TM, BCI® , BOISE GLULAMTm, BC FloorValue® , VERSA -LAW, VERSA -RIM PLUS®, Page 7 of 9 Ak Boise CascacW Single 16" BCI® 6000s-1.8 PASSELI 1st Floor\Floor Joists\FJ5(11539) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ5(i1539) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: B1 15-11-04 Total Horizontal Product Length = 15-11-04 Reaction Summary (Down / Uplift) (Ibs) _Bearing Live Dead Snow Wind Roof Live 61, 2-3/8" 637 / 0 159 / 0 B2, 2-3/8" 637 / 0 159 / 0 B2 Load Summary Live Dead Snow Wind Roof OCS Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-00-00 15-11-04 Top 80 20 n\a View Fill) Hole Summary Description Center Elevation Ref. Height Width Shape Orientation H01 08-00-00 8" L 12" Circular Horizontal H02 12-00-00 8" L 12" Circular Horizontal Controls Summary Value %Allowable Duration Case Location Pos. Moment 3068 ft-Ibs 55.8% 100% 1 07-11-04 End Reaction 797 Ibs 59.5% 100% 1 00-00-00 End Shear 777 Ibs 35.7% 100% 1 00-02-06 Hole #1 Shear 159 Ibs 26.2% 100% 2 08-00-00 Hole #2 Shear 440 Ibs 72.8% 100% 4 12-00-00 Total Load Deflection L/1021 (0.184") 23.5% n\a 1 07-11-04 Live Load Deflection U1277 (0.147") 37.6% n\a 6 07-11-04 Max Defl. 0.184" 18.4% n\a 1 07-11-04 Span / Depth 11.7 Hole Location Valid % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material 131 Wall/Plate 2-3/8" x 2-5/16" 797 Ibs 16.6% 59.5% Unspecified B2 Wall/Plate 2-3/8" x 2-5/16" 797 Ibs 16.6% 59.5% Unspecified Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJS-, ALLJOIST®, BC RIM BOARDTM, BCI® , BOISE GLULAMTM, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, Page 8 of 9 Boise cascacw = Single 16" BCI® 6000s-1.8 PASSED '.IC iYr[9zv xNlpO +NJUu:YS 1 st Flooffloor JoistslFJ6(11555) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ6(i1555) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: B1 03-08-14 Total Horizontal Product Length = 03-08-14 B2 i Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1, 3-1/2" 52 / 0 13 / 0 B2, 2-3/8" 58 / 0 15 / 0 Load Summary Live Dead Snow Wind Roof ocs Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-03-08 03-08-14 Top 32 8 n\a View Fill) Controls Summary Value %Allowable Duration Case Location Pos. Moment 57 ft-Ibs 1.0% 100% 1 01-11-00 End Reaction 73 Ibs 5.4% 100% 1 03-08-14 End Shear 65 Ibs 3.0% 100% 1 00-03-08 Total Load Deflection L/999 (0.001") n\a n\a 1 01-11-00 Live Load Deflection L/999 (0.001") n\a n\a 2 01-11-00 Max Defl. 0.001" n\a n\a 1 01-11-00 Span / Depth 2.5 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 3-1/2" x 2-5/16" 65 Ibs 0.9% 4.2% Unspecified B2 Wall/Plate 2-3/8" x 2-5/16" 73 Ibs 1.5% 5.4% Unspecified Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member Design based on Dry Service Condition. BC CALCO analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCO, BC FRAMER@ , AJSTM' ALLJOIST@ , BC RIM BOARDTm, BCI@ , BOISE GLULAMTM, BC FloorValueO , VERSA-LAMO, VERSA -RIM PLUS@ , Page 9 of 9 DESCRIPTION: LOT(S)56-63 TYSON TOWNHOMES, ACCORDING TO SEC. 2, TWP. 26 S, RNG 21 E. THE PLAT THEREOF, RECORDED IN PLAT BOOK 91, PAGE(S)130-135, SITE PLAN PASCO COUNTY, FLORIDA OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. (NOT A SURVEY) (TYSON TOWNHOMES) LOT = 14345 SO. FT. LIVING AREA = 4858 SO. FT. ENTRY = 249 SO. FT. GARAGE = 1771 SO. FT. COVERED LANAI = XXX SO. FT. PATIO = 320 SO. FT. POOL AREA = XXX SO. FT. CONC. DRIVE = 1344 SO. FT. A/C & CONIC PAD = 72 SO. FT. SIDEWALK = 278 SO. FT. SIDE YARD SWALE = XXX SO. FT. CONSERVATION AREA = XXX SO. FT. LOT OCCUPIED = 62 % AREA TO IRRIGATE = 38 % W This SITE PLAN Prepared for and Certified To: Starlight Homes i 55 i 72 92.70' •4• fV fV 0 i.o 0 z 17.0' _ o. . 0 43.0' _ O r o . �. •• •0z 56 - PROPOSED RESIDENCE d• -0 •� PUN 1386 7 'D C, 71 ELEV OR GARAGE -LEFT 4.0. A/C 0 15.0 ' S 89-43.08" E IPI 80.00' (P)tH " _______--- :0 . .0 .Mrs n ••1 -0- •'CT • I "�• ' - PROPOSED RESIDENCE 'Q = d PLAN 1387 4.0' S7 o 8 ELEV KR D. CO' O N, ., I �> GARAGE -LEFT ^ w ry A/C 70 1 y. a^ I ---- ------ ---------- N 89.43'08' W 1P) 80.00' (P) A/c P• PROPOSED RESIDENCE ' PLAN 1386 _ O : 4.0• 58 ELEVM - o 'r GARAGE -RIGHT P _ Q ... i 3 69 M ^t w , • S 89'43'08' E (P) 80.00' (P) M O ,. '�I. �' ••0 • .P PROPOSED RESIDENCE F- p Q p •I y _ PLAN 1387 ELEVAR Il - _ or ; y _ 4.0 59 GARAGE -LEFT p. p^ 4,D• G ' ry c0 L. NC 68 39.0' zz !" N----- G ------ © --------- N '- PROPOSED RESIDENCE 4.0• d C .0' 60 PLAN 1386 - C .. 4 :' ,.O ELEVK P GARAGE -RIGHT "- O' C F- D .+ T a. 67 P PROPOSED RESIDENCE PLAN 1386 Q. y r • . 4.0' 6 ELEV LR y O o GARAGE -LEFT P > 4.0• o N • D 4 0_wc 66 20.0' w 39.0' © A/C w PROPOSED RESIDENCE PLAN 1387 ,0' O •.O 4.0' 62 ELEV B 0; G D• M GARAGE -RIGHT - •O O _65 w a •. N 89'43' 8' W P 8 00' P ' a - - - - - - - 39.0' bp F EJ A/C - - - - - - - - - - Z PROPOSED RESIDENCE PLAN 1386 p 4.0' a p a. _. _•• a p 63 ELEvry P `D GA RAGE_Q G 64 - - - +' r2 10' UTILITY O' &SIDEWALK t EM1RT5' WALK �.'.: •.. ',. bo o• .. r .. 2 GUTTER _ PCP(P) ST. JOVITA STREET TRAqEAE -(HOA) RIGHT-OF-WAY [a =WATER METERS * = 10' UTILITY& SIDEWALK EASEMENT LEGEND: I CURVE 1 RADIUS 1 ARC LENGTH I CHORD LENGTH I CHORD BEARING 1 DELTA ANGLE C20 I 16.00 25.13 1 22.63 1 N 44.43'08" W 1 90.00'00" f' �= PROPOSED DRAINAGE FLOW + 00.00 = PROPOSED GRADE NOTES: PROPOSED: LOT GRADING TYPE =N/A MINIMUM FLOOR ELEVATIONS: PROPOSED PAD ELEVATION = 92.90' LIVING AREA: 93.57' FRONT SET BACK = 20' Scale: 1 " = 30' GARAGE AREA: SIDE SET BACK = 10' PROPOSED ELEVATIONS AND GRADING ELEVATIONS REFERENCED TO REAR SETBACK = 15' SHOWN HEREON ARE TAKEN FORM THE NORTH AMERICAN VERTICAL ENGINEERING PLANS OF DATUM OF 1988 "CLINTON CORNER SUBDIVISION", PREPARED APPARENT FLOOD HAZARD ZONE: X' COMMUNITY NO. 120235 BY BEACON CIVIL ENGINEERING PROVIDED SURVEY ABBREVATIONS (MAP NUMBER 12 10 1 C-0456-F) EFFECTIVE DATE: 09/26/2014 BY CLIENT A) =ARC LENGTH (D) = DEED INV = INVERT PC = POINT OF CURVE (R) = RECORD LEGEND VINYL FENCE A/C =AIR CONDITIONER DIE= DRAINAGE EASEMENT LB =LICENSED BUISNESS PCC = POINT OF COMPOUND CURVE RNG =RANGE � ,,� "'"�.L•.`I" AF -ALUMINUM FENCE EL OR ELEV = ELEVATION L.E = LANDSCAPE EASEMENT PCP PERMANENT CONTROL POINT RRS = RAIL ROAD SPIKE = CONC •>`�3'''f:"``� BFE = BASE FLOOD ELEVATION EDP = EDGE OF PAVEMENT LFE = LOWEST FLOOR ELEVATION P/E = POOL EQUIPMENT R/W = RIGHT OF WAY BM = BENCH MARK C = CURVE ESM'T = EASEMENT LS = LICENSED SURVEYOR PG = PAGE SEC = SECTION WOOD FENCE ASPHALT (C) =CALCULATED F/C =FENCE CORNER (M) =MEASURED PI = POINT OF INTERSECTION SN&D =SET NAIL AND DISK 4 = CENMRUNE FCM = FOUND CONCRETE MES - MITERED END SECTION PK =PARKER KALON LB#8183 CHAIN LINK FENCE CLF =CHAIN LINK FENCE MONUMENT NCF = NO CORNER FOUND 4 =PROPERTY LINE SIR =SET I/2' IRON ROD LB# 8183 = BRICK X X CMP = CORRUGATED METAL PIPE FIP = FOUND IRON PIPE O/A = OVERALL POB = POINT OF BEGINNING TBM = TEMPORARY BENCH MARK COL = COLUMN FIR = FOUND IRON ROD OHW = OVERHEAD WIRE(S) POC = POINT OF COMMENCTMENT TOB = TOP OF BANK C =CONCRETE FN&D = FOUND NAIL & DISK O.R. = OFFICIAL RECORDS POL = POINT ON LINE TWP = TOWNSHIP ALUMINUM FENCE S = CCONCRETE SLAB FOP = FOUND OPEN PIPE (P) - PLAT PRC = POINT OF REVERSE CURVE U.E = UTILITY EASEMENT COVERED \\ CST= T =CLEAR SIGHT TRIANGLE FPP = FOUND PINCHED PIPE PB - PLAT BOOK PRM = PERMANENT REFERENCE MONUMENT VF = VINYL FENCE JOB # SURVEYOR'S NOTES: SURVEYOR'S CERTIFICATE 1708 Water Oak Drive SSEE Plan:7-20-23 1.) Current title information on the subject property had not been This certifies tha fAJ% he hereon described k Afi� Tarpon Springs, Florida B9 Date of furnished to Initial Point Land Surveying, LLC. at the time of this SITE PLAN ,w u r pervision and property i�i meets t C f i ractice for Phone: (727)-831-1990 FloridaPLS7123@gmail.com RG IIN M RG. I.N.m RG.I.W RG.I.E. Z , Wp.,.S nVp 1 SE rH SITE CWC 2.) This sketch was prepared without the benefit of a title search. s surveyrd of Land �9 LB# 8183 Zo RG 1 W RG.1.E. Q No instruments of record reflecting ownership, easements or Surve47rs i tI 1 thro h •da °` D E S File: rights -of -way were furnished to the undersigned, unless otherwise shown hereon. J o A�1 hp ned 4" 2 02 Fl Drawn by: DJB 3.) Roads, walks, and other similar items shown hereon were taken r it trition e 1 Je 4 rtley StatCjeso , Checked by:JH from engineering plans and are subject to survey. 4.) This SITE PLAN does not reflect nor determine ownership. i p QBte: 4�08.24 P /ATE vF REVISIONS 5.) This SITE PLAN is subject to matters shown on the Plat of�� .p `"LORIC:2 f�114 00 �, 'TYSON TOWNHOMES" Jeff M. d'� Ze 6.) Dimensions shown hereon are in feet and decimal portions FLORIDA 1E ��1 OR AND Q thereof. MAPPER NO.�SIi��y � 3 7.) Contractor and owner are to verify all setbacks, building dimensions, and layout shown hereon prior to any construction, NOT VALID WITHOUT THE ORIGINAL and immediately advise Initial Point Land Surveying, LLC. of any SIGNATURE AND SEAL OF A FLORIDA P� deviation from information shown hereon. Failure to do so will be LICENSED SURVEYOR AND MAPPER Initial Point Land Surveying, LLC. at user's sole risk. Products DEAKIN6 HEI6HT SCHEDULE PlotID Length Product Plies Net Dtg Fab Type FJ1 20-00-00 16" BCI 4500s-1.8 2 16 MFD FJ2 5-00-00 16" BCI 4500s-16 2 16 MFD FJ3 20-00-00 16" BCI 6000s-1.8 1 88 MFD FJ4 20-00-00 16" BCI 6000s-1.8 1 16 MFD FJ5 16-00-00 16" BCI 6000s-1.8 1 56 MFD FJ6 4-00-00 16" BCI 6000s-1.8 1 8 MFD Rml 12-00-00 1-1/8" x 16" BC RIM BOARD DSB 1 Bkl 2-00-00 16" BCI 6000s-1.8 1 81 FF 80 FF Hanger List H1 HTU26 H2 IUS3.56/16 H3 IUS2.37/16 NBTE5: 1.) REFER TO HID 91 (REGOMMENDATION5 FOR HANDLING INSTALLATION AND TEMPORARY DRACING.) REFER TO ENGNEERED DRAWING5 FOR PERMANENT DRACING REQUIRED. 2.) ALL TRU55E5 (INCLUDING TRU55E5 UNDER VALLEY FRAMING) MUST DE COMPLETELY DECKED OR REFER TO DETAIL V105 FOR ALTERNATE DRACING REQUIREMENT5. 3.) ALL VALLEYS ARE TO DE CONVENTIONALLY FRAMED DY DUILDER. 4.) ALL TRU55E5 ARE DBIGNED FOR 2' o.c. MAXIMUM 5PACIN6. UNLE55 OTHERWISE NOTED. 5.) ALL WALLS 5HOWN ON PLACEMENT PLAN ARE CON51PERED TO DE LOAD DEARING. UNLE55 OTHERWI5E NOTED, 6.) 5Y42 TRU55E5 MUST DE I1,15TALLED WITH THE TOP BEING UP. 7.) ALL ROOF TRU55 HAN6ER5 TO DE 51MP5ON m HTU26 UNLE55 OTHERWI5E NOTED. ALL FLOOR TRU55 HANGER5 TO DE 51MP5ON THA422 UNLE55 OTHERWISE NOTED. 8.) DEAMIHEADER/LINTEL (HDR) TO DE FURN15HED DY BUILDER. E r 5HOP DRAWING APPROVAL THIS LAYOUT 15 THE SOLE 50U96E FOR FADRICATION OF TRU55E5 AND VOID5 ALL PREVIOUS ARCHITECTURAL OR OTHER TRU55 LAYOUT5. REVIEW AND APPROVAL OF THIS LAYOUT M15T DE RECEIVED BEFORE ANY TRU55E5 WILL DE DUILT. VERIFY ALL CONDITION5 TO IN5URE AGAIN5T CHANCES THAT WILL RE5ULT IN EXTRA CHARGES TO YOU. reganed Dc4rcry Da, Appromd by: Dac 6jBuilders .FirstSource Orlando PHONE: 407-851-2100 FAX 407-051-7111 Plant Gity PHONE: 813-759-5cl51 FAX: 613-752-1532 Starlight Homes DEL: Tyson TH 81.1nit A CAL ADDRE55: Lot 56-63 Bldg 9 YE: DPAN DY: 10-26-23 Rick PlotID Length Product Plies Net Otg Fab Type FJ1 20-00-00 16" BCI 4500s-I.B 2 16 MFD FJ2 5-00-00 16" BCI 4500s-I.8 2 16 MFD FJ3 20-00-00 16" BCI 6000s-I.8 1 68 MFD FJ4 20-00-00 16" BCI 6000s-1.8 1 16 MFO FJ5 16-00-00 16' BCI 6000s-1.8 1 56 MFD FJ6 4-00-00 16" BCI 60005-1.8 1 8 MFD Rml 12-00-00 1-1/8" x 16" BC RIM BOARD OSB 1 81 FF Bkl 2-00-00 16" BCI 6000s-1.8 1 80 FF REARING HEIGHT 5GHEDULE Hanger List H1 HTU26 H2 IUS3.56/16 H3 IUS2.37/16 NOTES: 1.) REFER TO HID 91 (REGOMMENDATIONS FOR HANDLING 1N5TALLATION AND TEMPORARY BRACING.) REFER TO ENGNEERED DRAWINGS FOR PERMANENT BRACING REQUIRED, 2.) ALL TRU55E5 (INCLUDING TRU55E5 UNDER VALLEY FRAMING) 1JU5T BE COMPLETELY DECKED OR REFER TO DETAIL V105 FOR ALTERNATE BRACING REQUIREMENT5. 3) ALL VALLEYS ARE TO DE CONVENTIONALLY FRAMED BY BUILDER. 4.) ALL TRU55E5 ARE DESIGNED FOR 2' o.G. MAXIMIM 5PACIN65, UNLE55 OTHERWI5E NOTED. 5.) ALL WALLS SHOWN ON PLACEMENT PLAN ARE CON0ERED TO BE LOAD DEARING, UNLE55 OTHERW15E NOTED. 6.) 5Y42 TRU55E5 M15T BE I1,15TALLED WITH THE TOP BEING UP. 7.) ALL ROOF TRU55 HANGERS TO BE 5IMP50N HTU26 UNLE55 OTHERW15E NOTED. ALL FLOOR TRU55 HAN6ER5 TO BE 5IMP5ON THA422 UNLE55 OTHERW15E NOTED, 8.) BEAM/HEADER/LINTEL (HOP) TO BE FURN15HED BY BUILDER. SHOP DRAWING APPROVAL TH15 LAYOUT 15 THE SOLE 5OURCE FOR FADRICATION OF TRU55E5 AND VOID5 ALL PREVIOU5 ARCHITECTURAL OR OTHER TRU55 LAYOUT5. REVIEW AND APPROVAL OF THI5 LAYOUT M)5T BE RECEIVED BEFORE ANY TRU55E5 WILL BE DUILT. VERIFY ALL CONDITION5 TO INSURE AGAIN5T 0HAN6E5 THAT WILL RESULT IN EXTRA CHAR6E5 TO YOU, RaAoastad Ddirarp Data pprorad by Data: Builders .First r Sou ce Orlando PHONE: 407-851-2100 FAX 407-851-7111 Plant City PHONE, 815-759-5Q51 FAX: 813-752-1532 Starlight Homes )EL Tyson TH 81Unit A 6AL ADDRESS: Lot 56-63 Bldg 9 EE DtAIIII PT: 10-26-23 1 Rick