Loading...
HomeMy WebLinkAbout6148-6178 Daerr Ridge St (2)®EM�GaE"EPED L1S Double 16" BCI® 4500s-1.8 PASSED 1st FloorTloor Joists\FJ1(i1553) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ1(i1553) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: 61 19-05-12 Total Horizontal Product Length = 19-05-12 62 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1, 2-3/8" 854 / 0 213 / 0 B2, 2-3/8" 1122 / 0 280 / 0 Load Summary Live Dead Snow Wind Roof OCS Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-00-00 19-05-12 Top 41 10 n\a View Fill) 2 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-00-00 15-10-10 Top 39 10 n\a View Fill) 3 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 16-00-06 19-05-12 Top 41 10 n\a View Fill) 4 FJ2(i1526) Conc. Pt. (Ibs) L 15-10-10 15-10-10 Top 417 104 n\a Hole Summary Description Center Elevation Ref. Height Width Shape Orientation H01 08-00-00 8" L 12" Circular Horizontal H02 12-00-00 8" L 12" Circular Horizontal Controls Summary Value %Allowable Duration Case Location Pos. Moment 5551 ft-Ibs 67.9% 100% 1 10-0774 End Reaction 1402 Ibs 59.4% 100% 1 19-05-12 End Shear 1382 Ibs 35.0% 100% 1 19-03-06 Hole #1 Shear 396 Ibs 36.1 % 100% 3 08-00-00 Hole #2 Shear 320 Ibs 29.1 % 100% 4 12-00-00 Total Load Deflection L/694 (0.332") 34.6% n\a 1 10-00-00 Live Load Deflection L/868 (0.266") 55.3% n\a 6 10-00-00 Max Defl. 0.332" 33.2% n\a 1 10-00-00 Span / Depth 14.4 Hole Location Valid % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 2-3/8" x 3-1/2" 1067 Ibs 14.7% 45.2% Unspecified B2 Wall/Plate 2-3/8" x 3-1/2" 1402 Ibs 19.3% 59.4% Unspecified Cautions Distributed side -load and/or concentrated side loads exceeds allowable magnitude for connection design. Please consult a technical representative or Professional Engineer for the design of the connection. All multiple member 16" BCIO 4500s-1.8 applications with side load or unevenly distributed top load require filler blocks and fasteners. See Boise Cascade Technical Note IJ-13 for further information. Page 1 of 9 MB0kQC88WX Double 16" BCI® 4500s-1.8 PASSED ENOMIEEMV W g10WCT5 1st Floor\Floor Joists\FJ1(i1553) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ1(i1553) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTM ALLJOIST®, BC RIM BOARDTm, BCI® , BOISE GLULAMTA1, BC FloorValue® , VERSA -LAW, VERSA -RIM PLUS®, Page 2 of 9 ®edwCasc" = Double 16" BCI® 4500s-1.8 PASSED E"DNEEIHD W000 MOWC3 1st Floor\Floor JoistslFJ2(i1526) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: list Floor\Floor Joists\FJ2(i1526) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: 1311 u 04-04-08 Total Horizontal Product Length = 04-04-08 B2 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1,2" 422/0 106/0 B2,4" 871/0 218/0 Load Summary Live Dead Snow Wind Roof ocS Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FJ5(i1545) Conc. Pt. (Ibs) L 01-09-10 01-09-10 Top 635 159 n\a 2 FJ5(i1533) Conc. Pt. (Ibs) L 03-09-10 03-09-10 Top 648 162 n\a Controls Summary Value % Allowable Duration Case Location Pos. Moment 885 ft-Ibs 10.8% 100% 1 01-09-10 End Reaction 1089 Ibs 36.9% 100% 1 04-04-08 End Shear 1089 Ibs 27.6% 100% 1 04-00-08 Total Load Deflection L/999 (0.006") n\a n\a 1 01-09-10 Live Load Deflection U999 (0.005") n\a n\a 2 01-09-10 Max Defl. 0.006" n\a n\a 1 01-09-10 Span / Depth 3.0 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Hanger 2" x 3-1/2" 528 Ibs 31.7% 18.3% IUS3.56/16 B2 Wall/Plate 4" x 3-1/2" 1089 Ibs 8.9% 36.9% Unspecified Cautions Hanger IUS3.56/16 requires (14) 10d face nails, (2) 10dx1.5 joist nails. Distributed side -load and/or concentrated side loads exceeds allowable magnitude for connection design. Please consult a technical representative or Professional Engineer for the design of the connection. All multiple member 16" BCI® 4500s-1.8 applications with side load or unevenly distributed top load require filler blocks and fasteners. See Boise Cascade Technical Note IJ-13 for further information. Web stiffeners (WSb) are required depending upon actual reaction, hanger type, or other web stiffener requirement at bearing(s) B1. Header for the hanger IUS3.56/16 is a Double 16" I -joist. Page 3 of 9 ®e�caw" = Double 16" BCI® 4500s-1.8 PASSED ENCMEEPEO WOW R CTS 1st Floor\Floor Joists\FJ2(11526) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ2(i1526) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Hanger Manufacturer: Simpson Strong -Tie, Inc. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTm, ALLJOIST®, BC RIM BOARD TM , BCI® , BOISE GLULAMTM, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, Page 4 of 9 I�Boisecnew Single 16" BCI® 6000s-1.8 PASSED ���TTT/// EMsINFEPEDWODDWIWULTS 1st FloorTloor JoistslFJ3(il548) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ3(i1548) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: B1 0 19-05-12 Total Horizontal Product Length = 19-05-12 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1. 2-3/8" 779 / 0 195 / 0 B2, 2-3/8" 779 / 0 195 / 0 B2 Load Summary Live Dead Snow Wind Roof OCS Live Tag Description Load Type Ref. Start End Loc. 100%D 90%D 115%D 160%D 125%D 1 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-00-00 19-05-12 Top 80 20 n\a View Fill) Hole Summary Description Center Elevation Ref. Height Width Shape Orientation H01 08-00-00 8" L 12" Circular Horizontal H02 12-00-00 8" L 12" Circular Horizontal Controls Summary Value %D Allowable Duration Case Location Pos. Moment 4612 ft-Ibs 83.9% 100% 1 09-08-10 End Reaction 974 Ibs 72.7% 100% 1 00-00-00 End Shear 954 Ibs 43.9% 100% 1 00-02-06 Hole #1 Shear 303 Ibs 50.1 % 100% 3 08-00-00 Hole #2 Shear 338 Ibs 56.0% 100% 4 12-00-00 Total Load Deflection L/587 (0.393") 40.9% n\a 1 09-08-10 Live Load Deflection L/734 (0.314") 65.4% n\a 6 09-08-10 Max Defl. 0.393" 39.3% n\a 1 09-08-10 Span / Depth 14.4 Hole Location Valid %D Allow %D Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 2-3/8" x 2-5/16" 974 Ibs 20.3% 72.7% Unspecified B2 Wall/Plate 2-3/8" x 2-5/16" 974 Ibs 20.3% 72.7% Unspecified Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTM, ALLJOIST®, BC RIM BOARDTm, BCI® , BOISE GLULAMTm, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS® , Page 5 of 9 M901"casoada' Single 16" BCI® 6000s-1.8 PASSED ewore[ Vwaoowro M 1 st Floor\Floor Joists\FJ4(i1527) (Floor Joist) BC Design Engine Member Report Dry 12 spans I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ4(i1527) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: 11-04-02 B1 Q B2 Total Horizontal Product Length = 19-05-12 08-01-10 B3 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B 1, 2-3/8" 403 / 20 96 / 0 B2, 3-1/2" 951 / 0 238 / 0 B3, 2-3/8" 302 / 78 56 / 0 Load Summary Live Dead Snow Wind Roof OCS Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-00-00 19-05-12 Top 80 20 n\a View Fill) Hole Summary Description Center Elevation Ref. Height Width Shape Orientation H01 08-00-00 8" L 12" Circular Horizontal H02 14-00-00 8" L 12" Circular Horizontal Controls Summary Value % Allowable Duration Case Location Pos. Moment 1179 ft-Ibs 21.5% 100% 2 04-11-13 Neg. Moment -1066 ft-Ibs 19.4% 100% 1 11-04-02 End Reaction 499 Ibs 37.3% 100% 2 00-00-00 Int. Reaction 1189 Ibs 44.9% 100% 1 11-04-02 End Shear 479 Ibs 22.0% 100% 2 00-02-06 Cont. Shear 641 Ibs 29.5% 100% 1 11-02-06 Hole #1 Shear 326 Ibs 54.0% 100% 4 08-00-00 Hole #2 Shear 268 Ibs 44.3% 100% 1 14-00-00 Total Load Deflection L/999 (0.043") n\a n\a 2 05-06-08 Live Load Deflection L/999 (0.035") n\a n\a 9 05-06-08 Total Neg. Defl. L/999 (-0.003") n\a n\a 2 14-01-08 Max Defl. 0.043" n\a n\a 2 05-06-08 Span / Depth 8.4 Hole Location Valid % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 2-3/8" x 2-5/16" 499 Ibs 10.4% 37.3% Unspecified B2 Wall/Plate 3-1/2" x 2-5/16" 1189 Ibs 16.8% 44.9% Unspecified B3 Wall/Plate 2-3/8" x 2-5/16" 358 Ibs 7.5% 26.8% Unspecified Page 6 of 9 sageC&9=W = Single 16" BCI® 6000s-1.8 PASSED E"W"EE"ED W E"0 TS 1 st Floor\Floor Joists\FJ4(11527) (Floor Joist) BC Design Engine Member Report Dry 12 spans I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ4(i1527) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTm, ALLJOIST®, BC RIM BOARD-, BCI® , BOISE GLULAMTm, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, Page 7 of 9 ®Bd"cascacw Single 16" BCI® 6000s-1.8 PASSED .EKDWOCOMI 's 1 st Floor\Floor Joists\FJ5(i1539) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ5(i1539) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: B1 0 15-11-04 Total Horizontal Product Length = 15-11-04 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B 1, 2-3/8" 637 / 0 159 / 0 B2, 2-3/8" 637 / 0 159 / 0 B2 Load Summary Live Dead Snow Wind Roof OCS Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-00-00 15-11-04 Top 80 20 n\a View Fill) Hole Summary Description Center Elevation Ref. Height Width Shape Orientation H01 08-00-00 8" L 12" Circular Horizontal H02 12-00-00 8" L 12" Controls Summary Value %Allowable Duration Case Location Pos. Moment 3068 ft-Ibs 55.8% 100% 1 07-11-04 End Reaction 797 Ibs 59.5% 100% 1 00-00-00 End Shear 777 Ibs 35.7% 100% 1 00-02-06 Hole #1 Shear 159 Ibs 26.2% 100% 2 08-00-00 Hole #2 Shear 440 Ibs 72.8% 100% 4 12-00-00 Total Load Deflection L/1021 (0.184") 23.5% n\a 1 07-11-04 Live Load Deflection L/1277 (0.147") 37.6% n\a 6 07-11-04 Max Defl. 0.184" 18.4% n\a 1 07-11-04 Span / Depth 11.7 Hole Location Valid % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 2-3/8" x 2-5/16" 797 Ibs 16.6% 59.5% Unspecified B2 Wall/Plate 2-3/8" x 2-5/16" 797 Ibs 16.6% 59.5% Unspecified Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2015. Calculations assume member is fully braced. Circular Horizontal Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTm, ALLJOIST®, BC RIM BOARDTm, BCI® , BOISE GLULAMT"', BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, Page 8 of 9 ®eaeacaeador = Single 16" BCI® 6000s-1.8 PASSED _v wro 's 1st FloorTloor JoistslFJ6(i1555) (Floor Joist) BC Design Engine Member Report Dry 11 span I No cant. 1 24" OCS I Repetitive I Glued & nailed March 15, 2023 11:07:13 Build 8548 Job name: File name: TTH1-9.mmdl Address: Description: 1st Floor\Floor Joists\FJ6(i1555) City, State, Zip: Specifier: Customer: Designer: Code reports: ESR-1336 Company: 1 L L 03-08-14 B1 132 Total Horizontal Product Length = 03-08-14 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1, 3-1 /2" 52 / 0 13 / 0 B2, 2-3/8" 58 / 0 15 / 0 Load Summary Live Dead Snow Wind Roof ocs Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 FC3 Floor Decking (Plan Unf. Lin. (lb/ft) L 00-03-08 03-08-14 Top 32 8 n\a View Fill) Controls Summary Value %Allowable Duration Case Location Pos. Moment 57 ft-Ibs 1.0% 100% 1 01-11-00 End Reaction 73 Ibs 5.4% 100% 1 03-08-14 End Shear 65 Ibs 3.0% 100% 1 00-03-08 Total Load Deflection L/999 (0.001") n\a n\a 1 01-11-00 Live Load Deflection L/999 (0.001") n\a n\a 2 01-11-00 Max Defl. 0.001" n\a n\a 1 01-11-00 Span / Depth 2.5 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 3-1/2" x 2-5/16" 65 Ibs 0.9% 4.2% Unspecified B2 Wall/Plate 2-3/8" x 2-5/16" 73 Ibs 1.5% 5.4% Unspecified Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (0.75") Maximum live load deflection criteria. Composite El value based on 7/8" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2015. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTM, ALLJOIST®, BC RIM BOARDTM, BCI® , BOISE GLULAMTm, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, Page 9 of 9 MNT LWnber design values are in accordance with ANSI/TPI 1 section 6.3 Ie hese truss designs rely on lumber values established by others. RE: TTH133-140 - MiTek, Inc. Site Information: 16023 Swingley Ridge Rd. ht Homes Customer Info: Starlight Project Name: TTH133-140 Model: Type 8A Chesterfield, MO 63017 1 YP 314.434.1200 Lot/Block: 133-140 Subdivision: Tyson Townhomes Address: ., City: Zephyrhills State: Florida Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.7 Wind Code: ASCE 7-16 Wind Speed: 150 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 32 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date No. Seal# Truss Name Date 1 T32315693 C1A 12/11/23 15 T32315707 T06A 12/11/23 2 T32315694 C3A 12/11/23 16 T32315708 T07 12/11/23 3 T32315695 CJ1 12/11/23 17 T32315709 T07A 12/11/23 4 T32315696 CJ3 12/11/23 18 T32315710 T09 12/11/23 5 T32315697 EJ5 12/11/23 19 T32315711 T10 12/11/23 6 T32315698 HJ5 12/11/23 20 T32315712 T10A 12/11/23 7 T32315699 T01 12/11/23 21 T32315713 T11 12/11/23 8 T32315700 T02 12/11/23 22 T32315714 V01 12/11/23 9 T32315701 T03 12/11/23 23 T32315715 V02 12/11/23 10 T32315702 T04 12/11/23 24 T32315716 V03 12/11/23 11 T32315703 T04A 12/11/23 25 T32315717 VO4 12/11/23 12 T32315704 T05 12/11/23 26 T32315718 V05 12/11/23 13 T32315705 T05A 12/11/23 27 T32315719 V06 12/11/23 14 T32315706 T06 12/11/23 28 T32315720 V07 12/11/23 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource - Plant City. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2025. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. `i111111111/#�� *% PQUIN VFW��ii G�E•N No 68182 iz 3 STATE OF :' J .;off O R 1 O P .. \�`�. ,`rS' �0 N A� 111 Ju q.in Velec PH 1a.68182 MiTek Inc. DBA MiTek USA FL Cerl 6636 16023 Swin8ley Ridge Rd. Ch-1—fleki. MO 63017 Dole: December 11,2023 Velez, Joaquin 1 of 2 Mi Tie ka RE: TTH133-140 - Site Information: Customer Info: Starlight Homes Lot/Block: 133-140 Address: ., City: Zephyrhills No. Seal# Truss Name 29 T32315721 V08 30 T32315722 V09 31 T32315723 V10 32 T32315724 V11 Project Name: TTH133-140 Model: Type 8A Subdivision: Tyson Townhomes Date 12/11 /23 12/11 /23 12/11 /23 12/11 /23 State: Florida 2 of 2 MiTek, Inc. 16023 Swingley Ridge Rd. Chesterfield, MO 63017 314.434.1200 Job Truss Truss Type Qty Ply T32315693 TTH133-140 CIA Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:47:48 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-zzzaKlGxyTtoda1 QMGCFXVR6rFdjkhzOmz7x46yB?yP 1-0-0 1-7-10 Scale = 1:9.0 2x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.12 Vert(LL) -0,00 2 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.03 Vert(CT) -0.00 2 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight: 7 Ill FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-7-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=82(LC 12) Max Uplift 3=-26(LC 9), 2=-122(LC 12) Max Grav 3=31(LC 17), 2=132(LC 1), 4=32(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown NOTES- (7) 1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; Cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 26 lb uplift at joint 3 and 122 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. JoagaN Velez PE Ns.62122 3LIek lac. DHA NDTek GSA 11. Cert 6634 16023 Swladey Ridge Rd. C kesterfteW. MO 63017 Date: December 11,2023 a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 1l2/2023 BEFORE USE. i �� �w Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damagge. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see A SI7TP 1 Ouallty Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T32315694 TTH133-140 C3A Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, -1-0-0 2x4 = 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:47:49 2023 Page 1 I D: tP uYC eVfQTfYt3OC?ZvfnpzlG U H-R9XyXeHZjn?fF kccw_jU4i_F SfyeT8DY?ds UdYyB?yO 3-3-10 M Scale = 1:13.2 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC20201TPI2014 CSI. TC 0.26 BC 0.11 WB 0.00 Matrix-P DEFL. in (loc) I/defl L/d Vert(LL) -0.01 2-4 >999 240 Vert(CT) -0.01 2-4 >999 180 Horz(CT) -0.00 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-3-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=126(LC 12) Max Uplift 3=-80(LC 12), 2=-138(LC 12) Max Grav 3=81(LC 17), 2=188(LC 1), 4=62(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-2-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 Ile uplift at joint 3 and 138 Ile uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin V.1- PE N..69122 W [ek lac. USA vRTek GSA k'L C en 6634 16023 Swlagley Ridge Rd. CYestrcneld. NO 63017 Da1r: December 11,2023 WARNING - Verify design parameters and READ NOTES ON TNIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTeV a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury antl ppropeertAyy damagge. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSURII Ouallty Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 1 MTek-US.com Job Truss Truss Type Oty Ply T32315695 TTH133-140 CA Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:47:50 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-vM5Lk_HBU47 WtuBpThEjcwWSL3JJCbThEHc19?yB?yN -1 0 14-14 1-0-0 14-14 Scale = 1:7.4 2x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.12 Vert(LL) -0.00 2 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 2 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 nla n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-P Weight: 6 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-4-14 oc puffins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=65(LC 12) Max Uplift 3=-17(LC 9). 2=-129(LC 12) Max Grav 3=19(LC 17), 2=127(LC 1), 4=27(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 17 lb uplift at joint 3 and 129 lb uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. JogeW Yelna PE N..69182 3D1.k lac. DNA WYe4 USA FL Cerr 66J4 1602J Swlyley RI6{e Rd. C'ae.I-R.W. MO 630] 7 D.tn: December 11,2023 WARNING - Verify design paramet— and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 112/2023 BEFORE USE. i �� �a Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and gpmrpejrry damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcswmponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Oty Ply T32315696 TTH133-140 CJ3 Jack -Open 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:47:51 2023 Page 1 ID:tPuYCeVfOTfYt3OC?ZvfnpzlGUH-NYf)yKIpFOFNVI m?l Pmy973ZXTdSx2jrSxLbhRyB?yM -1-0-0 3-9-11 1-0-0 3-9-11 2x4 = Scale = 1:12.4 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.35 BC 0.15 WB 0.00 Matrix-P DEFL. in (loc) I/defl L/d Vert(LL) -0.01 2-4 >999 240 Vert(CT) -0.02 2-4 >999 180 Horz(CT) -0.00 3 nla n/a PLATES GRIP MT20 244/190 Weight: 14 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SIP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-11 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=119(LC 12) Max Uplift 3=-87(LC 12), 2=-153(LC 12) Max Grav 3=87(LC 1), 2=205(LC 1), 4=72(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-8-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 87 lb uplift at joint 3 and 153 lb uplift at joint 2. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jognlo Velez PE No.63122 MiTek rac. URA .NnTek 1. SA FL (: ert 4434 16023 Swisgtey Rife Rd. C'It,m-frdd. MO 63017 Dato: December 11,2023 A WARNING - Verify design parameters and READ NOTES ON TMS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 11212023 BEFORE USE. ■ Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek' a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSWrPI1 Quality Criteria and OSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.mm) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T32315697 TTH133-140 EJ5 Jack -Open 34 1 Job Reference (optional) Builders Firssource (Tampa, FL), Tampa, FL - 33564, 1-0-0 1-0-0 3x4 = 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13AT52 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-rkD59gJROiN E6BLBb6HBhLcem swegVz_hb58DtyB?yL 5-0-0 5-0-0 5-0-0 Scale = 1:17.4 Plate Offsets (X,Y)-- [2:0-4-0,0-0-31 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) -0.03 2-4 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.28 Vert(CT) -0.06 2-4 >909 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020frPI2014 Matrix-P Weight: 18 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=173(LC 12) Max Uplift 3=-137(LC 12), 2=-155(LC 12) Max Grav 3=134(LC 17), 2=247(LC 1), 4=96(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=oft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fd between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 137 lb uplift at joint 3 and 155 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any This item has been particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin VMez PE Ico.64122 11i Inc. DBA NITe4 USA FL Cert 4634 16023 SMadey Ridge Rd. C lk-1.4.161, MO 63017 Dale: December 11,2023 WARNING -verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek* a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7rPl1 Quality Criteria and DSB-22 available from Truss Plate Institute (www1pinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T32315698 TTH133-140 HJ5 Diagonal Hip Girder 4 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, -1-6-12 3x4 = 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:47:53 2023 Page 1 ID: tPuYCeVfQTfYt3OC?ZvfnpzlGUH-JxnTN?K3n?V 5kLwO9goQEY81CG9SPyC7wFgim KyB?yK 7-8-13 Scale = 1:17.2 7-8-13 7-8-6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) 0.15 2-4 >603 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.33 2-4 >276 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20201TPI2014 Matrix-SH Weight: 26 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-4-9, 4=Mechanical Max Horz 2=172(LC 8) Max Uplift 3=-180(LC 8), 2=283(LC 8) Max Grav 3=183(LC 1), 2=388(LC 1), 4=148(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9) 1) Wind: ASCE 7-16; VuK=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 180 lb uplift at joint 3 and 283 lb uplift at joint 2. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 104 lb down and 23 lb up at 1-6-10, 85 lb down and 34 lb up at 2-6-11, and 47 lb down and 106lb up at 4-8-1, and 108 lb down and 95 lb up at 5-1-14 on top chord, and 5 lb down at 1-6-10, 8 lb down at 2-6-11, and 27 lb down at 4-8-1, and 23 lb down at 5-1-14 on bottom chord. The This item has been design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). electronically signed and 9) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any sealed by Velez, Joaquin, PE particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." using a Digital Signature. LOAD CASE(S) Standard Printed copies of this 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 document are not considered Uniform Loads (plf) signed and sealed and the Vert: 1-3=-54, 2-4=-20 signature must be verified Concentrated Loads (lb) on any electronic copies. Vert: 7=-3(F) 8=-2(B) 11=-5(F) 12=-5(B) Joaada Velez PE No.69192 Mielc Ine. DDA Vlflea GSA FL ('eel 66.14 1611 SwAQey Rldite Rd. Cb.f- W, NO 63017 Dale: December 11.2023 a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. i �� �k Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria and DSB-22 avaiable from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com Job T uss Truss Type Qty Ply T32315699 TTH133-140 T01 Hip Girder 2 Job Reference (optional) ouuaCrS nrJIAUUIGtl t 1 elope, r'L), —,p., — - 3JJ04, 0.1aU 5 NQV lJ LVLJ MI I eK inaus[nes, inc. rrl uec t113:4/:Dv Zuzs rage 1 I D: tP uYC e VfQTfYt3OC?Zvfn pzlG U H-858kd3Oq NrF F S G N XV4vq U pOtyhl B pVT01 B H OzzyB?yE 71-0-9 6-2-6 11--12 1%5-6 21-6-0 r 26-6-10 31-7-0 36-9-10 43-0-0 6-2E 5-2Fi 5-0-10 5-0-10 5-0-10 5 0 10 5-21 6-2-0 -0 5.00 F12 7x8 = 2x4 II 4x8 = 7x8 = 4x8 = 3 21 22 4 23 24 5 2526 27 6 28 2930 7 31 2x4 11 7x8 = 32 8 33 34 9 Scale = 1:73.6 5x8 = 20 35 36 19 37 38 1817 39 40 16 41 42 1514 43 44 13 45 46 12 5x8 = 2x4 11 5x8 = 7x8 WB = 4x8 = 2x4 11 5x8 = 2x4 11 2x4 7x8 WB = 43-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2020/TPI2014 CS1. TC 0.57 BC 0.35 WB 0.72 Matrix-SH DEFL. in Vert(LL) 0.82 Vert(CT) -0.96 Horz(CT) 0.13 (loc) I/defl L/d 16 >625 240 16 >534 180 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 531 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 'Except' TOP CHORD Structural wood sheathing directly applied or 4-4-13 oc purlins. 3-6,6-9: 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 8-1-10 oc bracing. BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=94(LC 7) Max Uplift 2=-1645(LC 8), 10=-1722(LC 8) Max Grav 2=2532(LC 1), 10=2602(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-5972/3778, 3-4=-8812/5811, 4-5=-8810/5809, 5-6=-11509/7662, 6-7=-11509/7662, 7-8=-8924/5934, 8-9=-8926/5936, 9-10=-6152/3976 BOT CHORD 2-20=-3371/5458, 19-20=-3370/5475, 17-19=-7061/10896, 16-17=-7061/10896, 15-16=-7123/10952, 13-15=-7123/10952, 12-13=-3553/5641, 10-12=-3554/5625 WEBS 3-20=0/450, 3-19=-2515/3773, 4-19=-495/505, 5-19=-2340/1584, 5-17=0/383, 5-16=-539/717, 6-16=-447/498, 7-16=-454/644, 7-15=0/383, 7-13=-2267/1515, 8-13=495/505, 9-13=-2451/3705, 9-12=0/449 NOTES- (11) 1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. This Item has been Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to electronically signed and ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. sealed by Velez, Joaquin, PE 3) Unbalanced roof live loads have been considered for this design. using a Digital Signature. 4) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. Printed copies of this p 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 document are not considered 5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific signed and sealed and the to the use of this truss component. signature must be verified 6) Provide adequate drainage to prevent water ponding. On any electronic copies. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Jos9ale %'Aei PE H0.64192 will fit between the bottom chord and any other members. wrek Loc. DBA Alfrek can FL Cert6634 16OL7 S.1ali Rldilie Rd. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1645 lb uplift at joint 2 and 1722 lb uplift Ch.1-field. n10 63017 at joint 10. Dere: December 11,2023 A WARNING - Verify design parameters and READ NOTES ON TW S AND INCLUDED MITEK REFERENCE PAGE MII-7471 rev. 1/2/2021 BEFORE USE. i �� �s Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and pennanem bracing is always required for stability and to prevent collapse with possible personal injury and DDropperrryry damag9ee. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUT►11 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcsoomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T32315699 TTH133-140 T01 Hip Girder 2 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:47:59 2023 Page 2 I D: tP uYC eVfQTfYt3OC?ZvfnpzlGU H-858kd3Oq NrF F S G NXV4vgUpOtyhl BpV TO18 HOzzyB?yE NOTES- (11) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 158 lb up at 6-2-6, 125 lb down and 153 lb up at 8-3-2, 125 lb down and 153 lb up at 10-3-2, 124 lb down and 153 lb up at 12-3-2, 124 lb down and 153 lb up at 14-3-2, 124 lb down and 153 lb up at 16-3-2, 124 lb down and 153 lb up at 18-3-2, 124 lb down and 153 lb up at 20-3-2, 124 lb down and 153 lb up at 21-6-0, 124 lb down and 153 lb up at 22-8-14, 124 lb down and 153 lb up at 24-8-14, 124 lb down and 153 lb up at 26-8-14, 124 lb down and 153 lb up at 28-8-14, 124 lb down and 153 lb up at 30-8-14, 125 lb down and 153 lb up at 32-8-14, and 125 lb down and 153 lb up at 34-8-14, and 225 lb down and 372 lb up at 36-9-10 on top chord, and 141 lb down at 6-2-6, 56 lb down at 8-3-2, 56 lb down at 10-3-2, 56 lb down at 12-3-2, 56 lb down at 14-3-2, 56 lb down at 16-3-2, 56 lb down at 18-3-2, 56 lb down at 20-3-2, 56 lb down at 21-6-0, 56 lb down at 22-8-14, 56 lb down at 24-8-14, 56 lb down at 26-8-14, 56 lb down at 28-8-14, 56 lb down at 30-8-14, 56 lb down at 32-8-14, and 56 lb down at 34-8-14, and 141 lb down at 36-8-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=54, 3-9=54, 9-11=-54, 2-10=-20 Concentrated Loads (lb) Vert: 3=-68(B) 9=-167(8) 20=-88(B) 5=-68(B) 17=-28(B) 16=-28(B) 6=-68(B) 15=-28(B) 7=-68(B) 12=-88(B) 21=-68(B) 22=-68(B) 23=68(13) 24=-68(B) 25=-68(B) 27=-68(B) 28=-68(B) 30=68(B) 31=-68(B) 32=-68(B) 33=-68(B) 34=-68(B) 35=-28(B) 36=-28(B) 37=-28(B) 38=-28(B) 39=-28(B) 40=-28(B) 41=-28(B) 42=-28(B) 43=-28(B) 44=-28(B) 45=-28(B) 46=28(13) WARNING - Verify design parameters and READ NOTES ON TFMS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. MiTeV Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and pproperlyy damage. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 oualay For and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314,434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T32315700 T-FH133-140 T02 Hip 2 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:01 2023 Page 1 ID:tPuYCeVfQTfYt30C?ZvfnpzlGU H-4TFV2kQ5uTWyhaXwdVxIZEUARUIPH SgJmVm72sy8?yC -1-7 8-7-3 15-1-10 21-6-0 27-10-6 34-4-13 37-10-9 43-0-0 -0- 5-1-7 3-5-12 6-6-7 64-6 6-4-6 6-6-7 3-5-12 5-1-7 -0- 3x4 = Sx6 = _ 5.00 12 3x4 = 4x6 — 3x4 = 5x6 = 4 21 522 23 6 7 24 825 26 9 0 Scale = 1:73.6 5x8 = 18 17 16 15 14 13 5x8 = 4x8 = 6x8 = 04 = 04 = 6x8 = 08 8-7-3 17-7-10 21-4-6 34-4-13 43-M 8-7-3 ~ 9-0-7 7-8-12 9-0-7 8-7-3 Plate Offsets (X,Y)-- [2:0-4-0,Edge], [4:0-3-0,0-2-4], [7:0-3-0,Edge], [9:0-3-0,0-24], [11:0-4-0,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) 0.63 15-16 >811 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.87 15-16 >591 180 BCLL 0.0 Rep Stress Incr YES WB 0.47 Horz(CT) 0.18 11 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 239 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-6-14 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 5-18, 8-13 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=-127(LC 10) Max Uplift 2=-943(LC 12), 11-943(LC 12) Max Grav 2=1642(LC 1), 11=1642(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3606/2164, 3-4=-3350/1984, 4-5=3101/1890, 5-6=4582/2725, 6-8=-4582/2725, 8-9=-3101/1890, 9-10=-3350/1984, 10-11=-3606/2164 BOT CHORD 2-18=-1889/3276, 16-18=-2429/4354, 15-16=-2620/4761, 13-15=-2412/4354, 11-13=-1906/3276 WEBS 3-18=-266/323, 4-18=-519/1010, 5-18=1504/893, 5-16=140/447, 6-16=-291/242, 6-15=-291/242, 8-15=-140/447, 8-13=-1504/893, 9-13=519/1010, 10-13=-266/323 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vud=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 8-7-3, Exterior(2R) 8-7-3 to 14-8-3, Interior(1) 14-8-3 to 34-4-13, Exterior(2R) 34-4-13 to 40-5-12, Interior(1) 40-5-12 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck to the use of this truss component. electronically signed and 4) Provide adequate drainage to prevent water ponding. Sealed by Velez, Joaquin, PE 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. using a Digital Signature. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Printed copies of this will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at document are not considered joint 11. signed and sealed and the 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any signature must be verified particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." on any electronic copies. Jeegele Vale. PE No.60132 NITek lee. Dl1A MiTek USA kL Cen 66d4 16023 Swiadey Rifte RA CkeelerfieN. NO 63017 Dale: December 11,2023 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek* a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damagge. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPl1 Quality For and SS-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T32315701 TTH133-140 T03 Hip 2 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:02 2023 Page 1 ID: tPuYCeVfQTfYt3OC?ZvfnpzlGU H-ZgptG4RjfinepJk66ADSX5SOJ WuB IOrnS_9 WgalyB?yB -i1-0-Q 6-6-5 11-0-0 18-0-9 24-11-7 32-0-0 36-5-11 43-0-0 -0-0 -0- 6-&5 4-5-11 7-0.9 6-10-13 7-0-9 T11 61i-5 .0-0 5x8 = 2x4 II 5.00 12 4 21 22 5 23 5x8 = 24 6 25 5x6 = 726 Scale = 1:73.7 3x6 18 17 16 15 14 13 12 11 3x6 2x4 II 3x4 = 4x6 — 3x10 = 2x4 II 5x6 = 3x8 = 2x4 II 6-6-5 11-0-0 18-0-9 24-11-7 32-0-0 36-5-11 4-" 6 6 5 4-5-11 7-0-9 6-10-13 7-0-9 44-11� 6Fi 5 Plate Offsets (X,Y)—[2:0-3-0,0-1-8],[4:0-5-12,0-2-8],[6:0-3-12,0-3-0],[7:0-3-0,0-2-4],[9:0-3-0,0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.87 Vert(LL) 0.52 14-15 >988 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.73 14-15 >699 180 BCLL 0.0 Rep Stress Incr YES WB 0.75 Horz(CT) 0.23 9 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 218 Ito FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 'Except' TOP CHORD Structural wood sheathing directly applied. 4-6: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 6-15, 6-12 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 9=0-3-8 Max Horz 2=159(LC 11) Max Uplift 2=-943(LC 12), 9=-943(LC 12) Max Gram 2=1642(LC 1), 9=1642(LC 1) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3513/2077, 3-4=-3065/1877, 4-5=-3608/2259, 5-6=-3608/2259,6-7=-2810/1792, 7-8=-3066/1877, 8-9=-3512/2077 BOT CHORD 2-18=-1794/3166, 17-18=-1794/3166, 15-17=-1479/2792, 14-15=-1949/3605, 12-14=-1949/3603, 11-12=-1806/3165, 9-11=-1806/3165 WEBS 3-17=-476/379, 4-17=-161/394, 4-15=-577/1078, 5-15=-398/374, 6-14=0/281, 6-12=-1058/570, 7-12=-462/882, 8-12=-475/379 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 11-0-0, Exterior(2R) 11-0-0 to 17-1-0, Interior(1) 17-1-0 to 32-0-0, Exterior(2R) 32-0-0 to 38-1-0, Interior(1) 38-1-0 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 9. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joequls \'aka PE N.Al lag 311iek Ina DBA 371Tek USA hL Cen "34 1602.1 SwWSlev Rklife Rd. Ckesrrrfleld, MO 63017 Data: December 11,2023 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 112/2023 BEFORE USE. i �� �a Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and propertydamage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434,1200 / MTek-US.com Job Truss Truss Type Oty Ply T32315702 TTH133-140 T04 Hip 15 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:04 2023 Page 1 ID:tPuYCeVfOTfYt3OC?ZvfnpzlGUH-V2xdhmSzBOuXY1 FVIdU?At6gvivRU171SS?nfByB?y9 -1-0.Q 7-0-5 13-4-13 18-9-10 24-2-6 29-7-3 35-11-11 43-0-0 q4-0-p 0 7-0-5 6�-8 5�-13 5-4-13 5-4-13 6�-8 7-0-5 5x6 = c nnF,—,- 3x4 = 5 20 3x4 = U6 = 6 7 5x6 = 8 Scale = 1.73.9 3x8 = 18 17 io cc — ID to Zo 14 13 12 3x8 = 2x4 II 3x8 = 4x6 3x4 = 4x6 = 3x8 = 2x4 II 7-0-5 133 4-13 21-6-0 29-7-3 35-11-11 43-0-0 7-0.5 6-4-8 8-1-3 8-1-3 6-0-8 7-0-5 Plate Offsets (X,Y)--[2:0-4-2,0-1-8],[4:0-3-0,0-2-4],[8:0-3-0,0-2-4],[10:0-4-2,0.1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.82 Vert(LL) -0.41 15-17 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.80 Vert(CT) -0.71 15-17 >724 180 BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(CT) 0.21 10 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 219 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.1 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-191(LC 10) Max Uplift 2=-943(LC 12), 10-943(1-C 12) Max Grav 2=1861(LC 17), 10=1861(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3963/2094, 3-4=-3216/1782, 4-5=-2947/1724, 5-7=-3388/1933, 7-8=-2947/1720, 8-9=-3216/1778, 9-1 0=-3964/2090 BOT CHORD 2-18=-1811/3722,17-18=-1811/3722,15-17=-1592/3365,13-15=-1587/3312, 12-13=-1819/3579, 10-12=-1819/3579 WEBS 3-18=0/276, 3-17=784/507, 4-17=-405/963, 5-17=-654/357, 5-15=0/254, 7-15=0/254, 7-13=-654/360, 8-13=-406/963, 9-13=-785/507, 9-12=0/276 Structural wood sheathing directly applied or 2-2-0 oc purlins. Rigid ceiling directly applied or 4-6-12 oc bracing. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. Il; Exp C, Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 13-4-13, Exterior(2R) 13-4-13 to 19-5-12, Interior(1) 19-5-12 to 29-7-3, Exterior(2R) 29-7-3 to 35-11-11, Interior(1) 35-11-11 to 44-0-0 zone; cantilever left and right exposed , end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. electronically Signed and 4) Provide adequate drainage to prevent water ponding. Sealed by Velez, Joaquin, PE 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. using a Digital Signature. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Printed copies of this will fit between the bottom chord and any other members, with BCDL = 10.Opsf. document 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at are not considered joint 10. signed and sealed and the 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any signature must be verified particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." on any electronic copies. Joegat. Velez PF. N..68182 MI Iek iae. DRA N1rek USA FL C'eri 6d34 16OL1 Cwieitky Ridge Rd. Ch.1-11.1d. NO 63017 Dare: December 11,2023 a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 1/2/2023 BEFORE USE. i �� �A Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damagge. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see A SVrr i Ouallty Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T32315703 TTH133-140 T04A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:05 2023 Page 1 I D: tP uYC eVfQTfYt3OC?Zvfn pz I G U H-zEV?u6TbyhOOAB qh s LOEj4egA6EZDC E uh6kKB dyB?y8 -1-0- 7-0-5 13-4-13 18-9-10 24-2-6 29-7-3 35-11-11 43-0-0 7-0-5 6-4-8 5-0-13 54-13 5-4-13 6-4-8 7-0-5 5x6 = 17rvgL 1 3x4 = 19 5 20 3x4 = 3x6 = 5x6 = 6 7 8 Scale = 1:73.8 3x8 = 17 16 is « Zs 14 L4 Zo 1J 12 11 3x8 = 2x4 11 3x8 = 4x6 3x4 = 06 = 3x8 = 2x4 11 29-7-3 35-11-11 43-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.85 BC 0.80 WB 0.77 Matrix-SH DEFL. in (loc) I/defl L/d Vert(LL) -0.41 12-14 >999 240 Vert(CT) -0.71 12-14 >723 180 Horz(CT) 0.21 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 217 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SIP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-4-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 10=0-3-8, 2=0-3-8 Max Horz 2=190(LC 11) Max Uplift 10=-857(LC 12), 2=-944(LC 12) Max Grav 10=1807(LC 18), 2=1861(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3964/2102, 3-4=-3217/1790, 4-5=-2948/1731, 5-7=-3390/1945, 7-8=-2951/1723, 8-9=-3220/1794, 9-1 0=-3964/21 00 BOT CHORD 2-17=-1855/3714, 16-17=-1855/3714, 14-16=-1622/3358, 12-14=-1637/3305, 11-12=-1846/3592,10-11=-1846/3592 WEBS 3-17=0/276, 3-16=784/507, 4-16=-405/964, 5-16=-655/358, 5-14=0/255, 7-14=0/253, 7-12=-654/357, 8-12=-416/965, 9-12=-793/515, 9-11=0/277 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vutt=150mph (3-second gust) Vasil=116mph; TCDL=4.2psf; BCDL=3.Opsf, h=25ft, B=45ft; L=43ft; eave=5ft; Cat. 11. Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 13-4-13, Exterior(2R) 13-4-13 to 19-5-12, Interior(1) 19-5-12 to 29-7-3, Exterior(2R) 29-7-3 to 35-11-11, Interior(1) 35-11-11 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck to the this truss electronically Signed and use of component. 4) Provide adequate drainage to prevent water ponding. Sealed by Velez, Joaquin, PE 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. using a Digital Signature. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Printed copies Of this will fit between the bottom chord and any other members, with BCDL = 10.Opsf. document 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 857 lb uplift at joint 10 and 944 lb uplift are not considered at joint 2. signed and sealed and the 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any signature must be verified particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." on any electronic copies. J-grda Velez PF N.A11132 W Iek be. DRA 31rlek USA tL Lem 6634 16023 Swiadey Ride Rd. Ck.wrneld, MO 63017 Date: December 11,2023 a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. i �� �x Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and pproperlAyy damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314,434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T32315704 TTH133-140 T05 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8,730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:07 2023 Page 1 I D:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-vddmJoVsUJG6PV_4zm2iOVk8kvvnhC6B8QDRF WYB?y6 -1-0-p 8�-0 15-9-10 21-6-0 27-2b 34-7-12 43-0-0 4,4-0� 8-4-0 7-5-5 5-8-6 5-8-6 7-5-5 8-4-4 -0- 5.00 12 5x8 = 2x4 II 5x8 = 5 18 6 1920 21 7 Scale = 1:75.2 3x8 = 16 15 — 14 11 13 12 3x8 = 2x4 11 5x6 = 3x8 = 5x6 = 2x4 11 8-4-4 15-9-10 21-6-0 27-2-6 34-7-12 43-0-0 8-4-0 7-5-5 5-8-6 5-8-6 7-5-5 8-4-4 Plate Offsets (X,Y)-- [2:0-4-2,0-1-81, [5:0.5-12,0-2-81, [7:0-5-12,0-2-81, [10:0-4-2,0-1-8], [13:0-3-0,0-3-0], [15:0-3-0,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.97 Vert(LL) 0.36 14 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.88 VeR(CT) -0.56 14-15 >920 180 BCLL 0.0 Rep Stress Incr YES WB 0.36 Horz(CT) 0.20 10 n/a n/a BCDL 10.0 Code FBC2020(TPI2014 Matrix-SH Weight: 222 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. 1-4,8-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-6-5 oc bracing. BOT CHORD 2x4 SP No.1 'Except' WEBS 1 Row at midpt 3-15, 9-13 13-15: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-223(LC 10) Max Uplift 2=-943(LC 12), 10=-943(LC 12) Max Grav 2=1861(LC 17), 10=1861(LC 18) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3888/2047, 3-5=-2973/1686, 5-6=2882/1743, 6-7=-2882/1743, 7-9=-2973/1686, 9-10=-3889/2047 BOT CHORD 2-16=-1752/3670, 15-16=-1752/3670, 14-15=-121712786, 13-14=-1230/2675, 12-13=-1766/3503, 10-12=-1766/3503 WEBS 3-16=0/345, 3-15=980/593, 5-15=-210/669, 5-14=-198/447, 6-14=-337/305, 7-14=-198/447, 7-13=-210/670, 9-13=-981/593, 9-12=0/345 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vutt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) 15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 10. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin VA.. PE No.69122 N11Tek lac. DBA 31n ek USA FL Cen 66d4 1602.1 SwlaSley Ridge Rd. CaestergeM. \10 6301' Date: December 11,2023 WARNING - Verify design parameters and READ NOTES ON TKS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek* a truss system. Before use, the building designer must vent' the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434A200 / MITek-US.com Job Truss Truss Type Qty Ply T32315705 TTH133-140 T05A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 813:48:09 2023 Page 1 ID: tPuYCeVfQTfYt3OC?ZvfnpzlGUH-sOkWkU W6OwWgfo8S5B4AtwpToja?96ZUbkiYKOyB?y4 - 8�-0 15-9-10 21Fi-0 27-2-6 34-7-12 43-0-0 -0- 8-0-4 7-5-5 I 5-8-6 5-8-0 7-5-5 8-4-4 Scale = 1:75.1 5.00 FIT 5x8 = 2x4 11 5x8 = 5 17 6 18 19 20 7 3x8 = 15 14 " 13 " 12 11 3x8 = 2x4 11 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 *Except* 1-4,8-10: 2x4 SP No.1 BOT CHORD 2x4 SP No.1 'Except` 12-14: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=221(LC 11) Max Uplift 2=-944(LC 12), 10=-857(LC 12) Max Grav 2=1861(LC 17), 10=1807(LC 18) 5x6 = 3x8 = 5x6 = 2x4 II 43-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TC 1.00 Vert(ILL) 0.36 13 >999 240 MT20 244/190 BC 0.90 Vert(CT) -0.56 12-13 >918 180 WB 0.36 Horz(CT) 0.20 10 n/a n/a Matrix-SH Weight: 220 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-4-12 oc bracing. WEBS 1 Row at midpt 3-14, 9-12 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3889/2054, 3-5=-2974/1694, 5-6=-2884/1753, 6-7=-2884/1753, 7-9=-2975/1694, 9-10=-3884/2055 BOT CHORD 2-15=-1797/3663, 14-15=-1797/3663, 13-14=-1261/2779, 12-13=-1249/2675, 11-12=-1791/3514,10-11=-1791/3514 WEBS 3-15=0/345, 3-14=-980/593, 5-14=-209/669, 5-13=-199/448, 6-13=-337/306, 7-13=-196/447, 7-12=-212/672, 9-12=-989/600, 9-11=0/346 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) 15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 Ito uplift at joint 10. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." I� This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jo.gma V loa PE N.A911112 Nliek lac. DBA N Tek USA hL Cert 6634 1602.3 Swiapey Rld{e Rd. Cke.terrrel6. NO 63017 D.re: December 11.2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1101II-7473 rev. 1/2/2023 BEFORE USE. i �� �rp Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and ppropertyy damagye. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Ouallry Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Oty Ply T32315706 TTH133-140 T06 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:11 2023 Page 1 I D:tPuYCeVfQTfYt3OC?ZvfnpzlGU HoOsH99YMYXmYu6lrCc7ezLurj WFBdsHn32BfOHyB?y2 -1-0- 6�-0 12-4-3 18-2-6 24-9-10 30-7-13 36-6-0 43-0-0 -0 -0- 6-6-0 5-10-3 5-10-3 6-7-3 5-10-3 5-10-3 6-6-0 -0- 5.00 12 5x6 = 6 20 5x8 = 721 Scale = 1:75.2 3x8 = -io [e Za 11 16 Zo 15 iv Zo a io 3x8 = 3x4 = 4x6 = 3x8 = 3x4 = 4x6 3x4 = 9-5-2 18-2-6 24-9-10 33-6-14 43-0-0 9-5-2 8-9-5 6-7-3 8-9-5 9-5-2 Plate Offsets (X,Y)--[2:0-4-2,0-1-8],[6:0-3-0,0-2-4],[7:0-5-12,0-2-8],[11:0-4-2,0-1-8] LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Ina YES BCDL 10.0 Code FBC2020frP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 `Except` 14-17: 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=-254(LC 10) Max Uplift 2=-943(LC 12), 11=943(LC 12) Max Grav 2=1872(LC 17), 11=1876(LC 18) CSI. DEFL. in (loc) I/defl L/d TC 0.84 Vert(LL) -0.40 13-15 >999 240 BC 0.98 Vert(CT) -0.70 13-15 >733 180 WB 0.99 Horz(CT) 0.20 11 n/a n/a Matrix-SH PLATES GRIP MT20 244/190 Weight: 223 Ib FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except: 5-8-0 oc bracing: 15-16. WEBS 1 Row at midpt 7-16 FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3934/2082, 3-5=-3693/1963, 5-6=2723/1603, 6-7=-2481/1552, 7-8=-2733/1603, 8-10=-3702/1963, 10-11=-3943/2082 BOT CHORD 2-18=-1800/3760, 16-18=-1470/3172, 15-16=-1093/2484, 13-15=-1483/3010, 11-13=-1813/3578 WEBS 3-18=-333/332, 5-18=-192/687,5-16=-820/522,6-16=-296/753, 7-15=-297/836, 8-15=-820/522, 8-13=-192/687, 10-13=-333/332 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft, B=4511; L=43ft, eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 18-2-6, Exterior(2R) 18-2-6 to 24-3-6, Interior(1) 24-3-6 to 24-9-10, Exterior(2R) 24-9-10 to 30-7-13, Interior(1) 30-7-13 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at joint 11. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Io This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. J-qula Velez PF Ns.68182 %0Tek tac. DaA .N1IFek C8A FL ten 66J4 1602J Swiedey Ridife Rd. C'lliesler6eld. VO 63017 13.1e: December 11,2023 O WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T32315707 TTH133-140 T06A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:12 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-GbQfMW_JruO WGtt mJetVZRO_waSMJSwlixCxjyB?y 1 12-4-3 18-2E 24-9-10 30-7-13 36-6-0 43-0-0 6�-0 5-10-3 5-10-3 6-7-3 5-10-3 5-10-3 6-" Scale = 1:75.1 Sx6 = 5.00 12 6 19 5x8 = 720 3x8 = " "' 15 41 14 1O co co 11 3x8 = 3x4 = 4x6 = 3x8 = 3x4 = 4x6 3x4 = Io 9-5-2 18-2-6 24-9-10 33-6-14 43-0-0 94-2 8-9-5 6-7-3 8-9-5 9-5-2 Plate Offsets (X,Y)--[2:0-4-2,0-1-8],[6:0-3-0,0-2-4],[7:0-5-12,0-2-8] [11:0-4-2 0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.87 Vert(LL) -0.40 12-14 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.70 12-14 >734 180 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(CT) 0.20 11 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 221 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-13 oc purlins. BOT CHORD 2x4 SP No.1 'Except' BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except: 13-16: 2x4 SP No.2 5-7-5 oc bracing: 14-15. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-15 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=253(LC 11) Max Uplift 2=-944(LC 12), 11=-857(LC 12) Max Grav 2=1873(LC 17), 11=1822(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3935/2089, 3-5=-3693/1971, 5-6=-2725/1611, 6-7=-2483/1560, 7-8=-2734/1605, 8-10=-3710/1974, 10-11=-3954/2108 BOT CHORD 2-17=-1844/3753, 15-17=-1514/3165, 14-15=-1112/2483, 12-14=-1504/3011, 11-12=-1842/3589 WEBS 3-17=-333/332, 5-17=-192/687, 5-15=-820/522, 6-15=-297/754, 7-14=-298/837, 8-14=-823/525, 8-12=-217/693, 10-12=-338/353 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vutt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 18-2-6, Exterior(2R) 18-2-6 to 24-3-6, Interior(1) 24-3-6 to 24-9-10, Exterior(2R) 24-9-10 to 30-7-13, Interior(1) 30-7-13 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at joint 11. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jwgnln Velez PE Te.69132 %Hrek 1aa. DBA VBTek USA FL Ceri 604 16023 Saringley Ridge Rd. CYealerrreld. NO 6M17 Dare: December 11,2023 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTeks a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T32315708 TTH133-140 T07 Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8,730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:14 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-CzYPnBaFgSB6laOQtkgLa_WOmkHEgM1 DIOQJ?cyB?y? 13-0 0 19-1-8 23-10-8 30A-0 35-11-15 43-0-0 4q-0-0 7-0-1 5-11-15 6-1-8 4-9-0 6-1-8 5-11-15 7-0-1 -0. 5x6 = 5.00 12 5x8 = Scale = 1:75.2 3x8 = io n cc 11 16 Zit 15 'q L4 Zo io 3x8 = 3x4 = 5x6 WB = 3x8 = 3x4 = 5x6 WB = 3x4 = I� 9-10-15 19-1-8 23-10-8 33-1-1 43-0-0 9-10-15 9-2-9 4-9-0 9-2-9 9-10-15 Plate Offsets (X,Y)-- [2:0-4-2,0-1-8], [6:0-3-0,0-2-4], [7:0-5-12,0-2-8], [11:0-4-2 0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) -0.40 13-15 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -0.70 13-15 >728 180 BCLL 0.0 Rep Stress Incr YES WB 0.41 Horz(CT) 0.17 11 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 228 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-3-0 oc purlins. 1-4,9-12: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP 285OF 2.0E or 2x4 SP M 31 'Except* WEBS 1 Row at midpt 5-16, 7-16. 8-15 14-17: 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=267(LC 11) Max Uplift 2=-943(LC 12), 11=-943(LC 12) Max Grav 2=1871(LC 17). 11=1873(LC 18) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-3899/2048, 3-5=-3656/1936, 5-6=-2628/1546, 6-7=-2388/1500, 7-8=-2631/1546, 8-10=-3661/1936, 10-11=-3905/2048 BOT CHORD 2-18=-1764/3735, 16-18=-1422/3112, 15-16=-1019/2395, 13-15=-1434/2951, 11-13=-1776/3539 WEBS 3-18=-351/346, 5-18=-214/750, 5-16=-877/557, 6-16=-330/762, 7-15=-326/836, 8-15=-879/558, 8-13=-214/751, 10-13=-351/346 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 19-1-8, Exterior(2E) This item has been 19-1-8 to 23-10-8, Exterior(2R) 23-10-8 to 30-0-0, Interior(1) 30-0-0 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific sealed by Velez, Joaquin, PE to the use of this truss component. using a Digital Signature. 4) Provide adequate drainage to prevent water ponding. Printed COpI@S Of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide document are not considered will fit between the bottom chord and any other members, with BCDL=10.0psf. signed and sealed and the 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at signature must be verified joint 11. on any electronic copies. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Joaquin Velez PE Ne.68132 .NBT.k lac. DRA 3JIT'ek USA FL C'-i 6634 16023 Swtadev Ridge Rd. Chesterfield, MO 0017 Dale: December 11,2023 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. I �� �x Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropertrtyy damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage. delivery, erection and bracing of trusses and truss systems, see ANSlrrrll Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T32315709 TTH133-140 T07A Hip 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:15 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-gA6n_XbtbmGzNjbcRRBa7B3ZA8dVZpH N_g9sX2yB?y_ -�-0-p 7-0-1 13-0-0 19-1-8 23-10-8 30-0-0 35-11-15 43-0-0 7-:11 5-11-15 6-1-8 4-9-0 6-1-11 5-11-15 7-0-1 Scale = 1:75.1 5x6 = 5.00 12 5x8 = 3x8 = II zu n 10 15 zz 14 111 e3 za Ile 3x8 — 3x4 = 5x6 WB = 3x8 = 3x4 = 5x6 WB = 3x4 = 9-10-15 19-1-8 23-10-8 33-1-1 43-0-0 9-10-15 ' 9-2-9 4� 9-2-9 9-10-15 Plate Offsets (X,Y)--[2:0-4-2,0-1-81,[6:0-3-0,0-2-41,[7:0-5-12,0-2-81,[11:0-4-2,0-1-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) -0.40 12-14 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -0.70 12-14 >729 180 BCLL 0.0 Rep Stress Incr YES WB 0.41 Horz(CT) 0.17 11 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 227 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. 1-4,9-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP 2850F 2.0E or 2x4 SP M 31 'Except* WEBS 1 Row at midpt 5-15, 7-15, 8-14 13-16: 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 11=0-3-8 Max Horz 2=265(LC 11) Max Uplift 2=-944(LC 12), 11=857(LC 12) Max Grav 2=1871(LC 17), 11=1819(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3900/2055, 3-5=-3656/1944, 5-6=2629/1554, 6-7=2389/1507, 7-8=2633/1549, 8-1 0=-3669/1950, 10-11 =-3914/2074 BOT CHORD 2-17=-1808/3727, 15-17=-1466/3104, 14-15=-1038/2387, 12-14=-1455/2952, 11-12=-1805/3550 WEBS 3-17=-351/346, 5-17=-214/750, 5-15=-877/557, 6-15=-331/763, 7-14=-327/837, 8-14=-881/560, 8-12=-238/757, 10-12=-354/365 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuh=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCOL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 19-1-8, Exterior(2E) This item has been 19-1-8 to 23-10-8, Exterior(2R) 23-10-8 to 30-0-0, Interior(1) 30-0-0 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific sealed by Velez, Joaquin, PE to the use of this truss component. using a Digital Signature. 4) Provide adequate drainage to prevent water ponding. Printed COp12S Of this 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide document are not considered will fit between the bottom chord and any other members, with BCDL = 10.Opsf. signed and sealed and the 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at signature must be verified joint 11. on any electronic copies. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." JI-intn Vole. PE Nn.62122 NITek lnr. DBA 2WFek C SA 4L Cert 6634 16071 Swisti RMOe Rd. C16.1-rwM. MO 63017 Dale: December 11,2023 WARNING - verity design parameters and READ NOTES ON TMS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTeka a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and propeM damaggee. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 QualRy Criteria and SS-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Informatlon available from the Structural Building Component Association (www.sbcscomponents.com) 314,434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T32315710 TTH133-140 T09 Common Supported Gable 14 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:17 2023 Page 1 I D:tPUYCBVfQTfYt3OC?ZvfnpzlGU H-dYDYPDc77NXhcl I?ZsD2Cc82mxV21 oNgR_ezbxyB?xy -1- 21-6-0 43-0-0 21-6-0 21-6-0 Scale = 1:73.0 5x6 = 5.00 F12 13 14 Iy 0 3x6 = 3x6 = 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 3x6 = 3x6 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.17 Vert(LL) -0.00 1 n/r 120 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 Bc 0.18 Vert(CT) 0.00 1 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(CT) 0,01 24 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 271 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 WEBS 1 Row at midpt 13-35, 12-36, 14-34 REACTIONS. All bearings 43-0-0. (lb) - Max Horz 2=297(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 36, 39, 40, 41, 42, 44, 34, 31, 30, 29, 28, 26, 24 except 37=-104(LC 12), 43=-104(LC 12), 45=-153(LC 12), 33=-104(LC 12), 27=-107(LC 12), 25=-179(LC 12) Max Grav All reactions 250 lb or less at joint(s) 2, 35, 36, 37, 39, 40, 41, 42, 43, 44, 34, 33, 31, 30, 29, 28, 27, 26, 24 except 45=258(LC 17). 25=271(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 9-10=-113/307, 10-11=-128/376, 11-12=-152/448, 12-13=-176/512, 13-14=-176/512, 14-15=-1521448, 15-16=-128/376, 16-17=-104/307 WEBS 3-45=-180/332, 23-25=-186/377 NOTES- (12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft, L=43ft; eave=2ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 3-6-0, Exterior(2N) 3-6-0 to 21-6-0, Comer(3R) 21-6-0 to 25-9-10, Exterior(2N) 25-9-10 to 43-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 36, 39, 40, 41, 42, 44, 34, 31, 30, 29, 28, 26, 24 except (jt=lb) 37=104, 43=104, 45=153, 33=104, 27=107, 25=179. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 24. 12) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagala Velez PC No.63132 Ntiek Lac. DBA MJTe4 GSA FL C.m 6634 16OLi Swlatjley Bld{e PA Caealeraeld. MU f3017 Dare: December 11,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and pproppertyy damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see AN5ITPII Quality Criteria and guidance available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Dty Ply T32315711 TTH133-140 T10 Common 32 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 813:48:19 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-ZxLlqueNf_nPsLvNgHGWH1 DCbI_3VTAyvl74gpyB?xw -1-0-Q 7-7-3 14±-10 21-6-0 28-5-6 35-4-13 43-0-0 4,4-0-Q -0- 7-7-3 6-11� 6-11-6 6-11-6 6-11-6 7-7-3 -0- 5x6 = 5.00 F12 Scale = 1:72.2 3x8 = it cc io -ram cv co w - co ci ,a 3x8 = 3x4 = 4x6 = 3x4 = 3x4 = 4x6 = 17-3-15 25-8-1 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 LUMBER. TOP CHORD 2x4 SP No.2 *Except* 1-4,8-11: 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=298(LC 11) Max Uplift 2=-943(LC 12), 10=-943(LC 12) Max Grav 2=1885(LC 17), 10=1885(LC 18) 3x4 = CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.91 Vert(LL) -0.40 14-15 >999 240 MT20 244/190 BC 0.92 Veri(CT) -0.68 14-15 >751 180 WB 0.99 Horz(CT) 0.18 10 n/a n/a Matrix-SH Weight: 218 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-3931/2002, 3-5=-3802/2010, 5-6=-2890/1661, 6-7=-2890/1661, 7-9=-3802/2010, 9-10=-3932/2002 BOT CHORD 2-17=-1708/3783, 15-17=-1306/3020, 14-15=-850/2218, 12-14=-1307/2872, 10-12=-1708/3560 WEBS 6-14=-520/1153, 7-14=-763/574, 7-12=-392/909, 9-12=-362/365, 6-15=-520/1153, 5-15=-763/574, 5-17=-392/908, 3-17=362/365 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) 21-6-0 to 25-9-10, Interior(1) 25-9-10 to 44-0-0 zone; cantilever left and right exposed , end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=943,10=943. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 3oegw. Yelez PE Ne.69122 NIIek tar- DBA YDIek USA tL Cer1 6634 16071 %wtal ley Ridge Rd. CYrrterrield. S70 63017 Da1r: December 11,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. I �� o Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropeerrtyry damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1 PII Quality Criteria and Ks-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponenls.com) 314.434.1200 / MiTek-US.com Job Truss T as Type City Ply T32315712 TTH133-140 T10A COMMON 16 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 813:48:21 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-VJT3FafeBcl75e3moi I_NSJYhYgLzNeFMccAkiyB?xu -1-0-0 7-7-3 14-6-10 21-6-0 28-5-6 M4-13 43-0-0 -0- 7-7-3 6-11-6 6-11-6 6-11-6 6-11-6 7-7-3 5x6 = 5.00 F12 Scale = 1:72.2 3x8 = io n io -1 co w io is LJ 1. 11 3x8 3x4 = 4x6 = 3x4 = 3x4 = 4x6 = 3x4 = 17-3-15 25-8-1 31-11-10 43-M 9-0-6 M 8-3-10 B-4-1 B-3-10 9-0-6 LOADING (psf) SPACING- 2-0.0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 *Except* 1-4,8-10: 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=297(LC 11) Max Uplift 2=-944(LC 12), 10=857(LC 12) Max Grav 2=1886(LC 17), 10=1831(LC 18) CSI. DEFL. in (loc) I/defl L/d TC 0.94 Vert(LL) -0.40 13-14 >999 240 BC 0.93 Vert(CT) -0.68 13-14 >750 180 WB 0.99 Horz(CT) 0.18 10 n/a n/a Matrix-SH PLATES GRIP MT20 244/190 Weight: 216 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-3932/2003, 3-5=-3803/2012, 5-6=-2892/1662, 6-7=-2892/1671, 7-9=-3811/2048, 9-1 0=-3941/2041 BOT CHORD 2-16=-1752/3776, 14-16=-1350/3012, 13-14=-893/2210, 11-13=-1327/2872, 10-11=-1768/3571 WEBS 6-13=-521/1155, 7-13=-766/577, 7-11=-422/916, 9-11=-365/381, 6-14=-520/1153, 5-14=-763/574, 5-16=-391/908, 3-16=-362/365 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuH=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) 21-6-0 to 25-9-10, Interior(1) 25-9-10 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=944, 10=857. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." I� This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaqulu Velez PF No.611132 3LTek Luc. DDA �D'Iek USA 67. C'er1 6634 1602.1 Swiattlec Ridge Rd. CbcuerfiieW. NO 63017 Dare: December 11,2023 a WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. ■ Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek'a a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property dama?e. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see A SIrrP 1 Oual ly Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T32315713 TTH133-140 T11 Common 8 1 Job Reference (optional) Builders FirslSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:22 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-zW1 RSwgGyv9JodyLPpDvgrjsy0nigyPbGMkGByB?xt -r1-0-Q 7-7-3 14-0-10 21- 0 28-5-6 35-4-13 43-0-0 45-0-0 -10 7-7-3 6-11-6 6-11-6 6-11-6 6-11-6 7-7-3 Scale = 1:73.7 5x6 = 5.00 12 11i 3x4 = 4x6 = 3x4 = 3x4 = 3x4 = 4x6 = 9-0-0 17-3-15 25-8-1 33-11-10 43-0-0 9-021 8-3-10 8-4-1 + 8-3-10 9-0-6 Plate Offsets (X,Y)— [2:0-4-2,0.1-8], [4:0-3-0,Edge], [8:0-3-0,Edge], [10:0-4-2,0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(L-) -0.40 14-15 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(CT) -0.68 14-15 >755 180 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(CT) 0.18 10 nla n/a BCDL 10.0 Code FBC20201TPI2014 Matrix-SH Weight: 220 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. 1-4,8-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-310(LC 10) Max Uplift 2=-939(LC 12), 10=-1020(LC 12) Max Grav 2=1885(LC 17), 10=1934(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3930/1998, 3-5=-3800/2006, 5-6=2887/1656, 6-7=-2886/1647, 7-9=-3779/1968, 9-10=-3921/1959 BOT CHORD 2-17=-1668/3790, 15-17=-1252/3027, 14-15=-827/2225, 12-14=-1281/2868, 10-12=-1668/3535 WEBS 6-14=-516/1150, 7-14=-758/569, 7-12=-359/890, 9-12=-354/345, 6-15=-519/1153, 5-15=-763/575, 5-17=-392/908, 3-17=-362/365 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp C; Encl., 13Cpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) 21-6-0 to 25-9-10, Interior(1) 25-9-10 to 45-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. electronically signed and 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. sealed by Velez, Joaquin, PE 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using a Digital Signature. will fit between the bottom chord and any other members, with BCDL = 10.Opsf. Printed COpleS Of this 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) document 2=939, 10=1020. are not considered 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any signed and sealed and the particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." signature must be verified on any electronic copies. Jmagmla Velez PF N..69122 MITek tar. DBA MITek CSA F'L Carr 66d4 16023 tiwiylov "e Rd. Ch.1-11e1d. MO 63017 Date: December 11.2023 a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. ■ Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTeV a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general g Adance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSI7rrI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T32315714 TTH133-140 Vol GABLE 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8 d 2x4 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:24 2023 Page 1 I D:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-vu8Blci WUXPiy6nLTgrh_4xF?mtVAyBh2arrL1 yB?xr 11-1-0 4x4 = 2x4 11 2x4 11 2x4 11 2x4 Scale = 1:17,8 .a O LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.17 BC 0.13 WB 0.11 Matrix-SH DEFL. in (loc) I/deft L/d Vert(LL) n/a n/a 999 Vert(CT) n/a n/a 999 Horz(CT) 0.00 5 n/a n/a PLATES GRIP MT20 244/190 Weight: 38 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 11-1-0. (lb)- Max Horz 1=55(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 8=-184(LC 12), 6=-184(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=279(LC 1), 6=279(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-187/368, 4-6=187/368 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30111; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 5-6-8, Exterior(2R) 5-6-8 to 8-6-8, Interior(1) 8-6-8 to 10-3-15 zone; cantilever left and right exposed , end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except This item has been Qt=lb) 8=184, 6=184. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any electronically signed and particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagala Velez PE Neb8122 .%Biek tot. DBA NRbk USA 4L cm 6634 1602.t Swtadey RW@t Rd. C116-04eW. MO 63017 Date: December 11,2023 a WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not i �� �A a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and proper damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP 1 Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www,sbcscomponents.com) 314.434.1200 / MTek-US.com Job Truss Truss Type Qty Ply T32315715 TTH133-140 V02 Valley 1 1 Job Reference (optional) Builders FirstSouroe (Tampa, FL), Tampa, FL - 33564, 4-0-0 3x4 2x4 II 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:25 2023 Page 1 ID: tPuYCeVfQTfYt3OC?ZvfnpzlGU H-05iZ5yi8FgXYaGMX1 YNwXITOHAB WVPirHEaOtTyB?xq 8-0-0 4-0-0 4x4 = 3x4 Scale = 1:14.6 .9 d 7-11-6 8-pr0 7-11-6 0- -10 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.27 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-SH Weight: 24 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=7-10-13, 3=7-10-13, 4=7-10-13 Max Horz 1=37(LC 11) Max Uplift 1=-64(LC 12), 3=-64(LC 12), 4=-133(LC 12) Max Grav 1=107(LC 23), 3=107(LC 24), 4=273(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-169/308 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuK=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed , end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=1b) 4=133. This item has been 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagnln Velez PE Nb.69192 NI7ek Lac. UBA.Mffek USA kL Cerr 6634 16OLt Swintil Mile Rd. Clesterneld. MO 6M17 Date: December 11,2023 WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual Wilding component, not MiTek* a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropertyy damagge. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI,1 Qualily Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.mm) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T32315716 TTH133-140 V03 Valley 2 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:26 2023 Page 1 ID: tPuYCeVfQTfYt3OC?ZvfnpzlGU H-sHGyl IjmOBfPBQxjaFu94VObrZa5etN_WuKxPvyB?xp 2-M 4-M 2x4 � 2x4 Plate Offsets (X,Y)-- [2:0-3-0,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.12 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020frP12014 Matrix-P Weight: 10 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SIP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-0-0, 3=4-0-0 Max Horz 1=-14(LC 10) Max Uplift 1=-50(LC 12). 3=-50(LC 12) Max Grav 1=92(LC 1), 3=92(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuK=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft, Cat. Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. JwgaM Vole& PE N..69132 MTea Iu- DBA WTea USA FL C ert 6634 160V Swlyley RWae Rd. Clu,.I-lteW, NO 63017 Date: December 11,2023 A& WARNING - verify design parameters and READ NOTES ON T10S AND INCLUDED MITEK REFERENCE PAGE 114II-7473 rev. 1/2/2023 BEFORE USE. ■ Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropertyy. damagge. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIRPII Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434,1200 / MiTek-US.com Job Truss Truss Type Qty Ply T32315717 TTH133-140 VO4 GABLE 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 813:48:27 2023 Page 1 ID: tPuYCeVfQTfYt3OC?ZvfnpzlGU H-KTgKVdkOnSnGpZWw8zPOcjZm NzwsN Kd8kX3VyLyB?xo 2-1-8 4-3-0 , 3x6 = Scale: 1.5"=1' 5.00 12 rd d 2x4 -:-- 2x4 4-3-0 4-3-0 Plate Offsets (X,Y)-- [2:0-3-0,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020rrPI2014 Matrix-P Weight: 11 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-3-0 oc purlins. BOT CHORD 2x4 SIP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-3-0, 3=4-3-0 Max Horz 1=-16(LC 10) Max Uplift 1=-55(LC 12), 3=-55(LC 12) Max Grav 1=101(LC 1), 3=101(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagalo Velez PF Ne.68182 WTek lac UBA .Wfek USA FL Ccrr 6634 16023 Swieglev RWae Rd. CYesi ield, MO 63017 Date: December 11,2023 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. ■ Design valid for use only with MTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek* a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropelrty damege. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrP I Quallly Criteria and DSB-22 available from Truss Plate Institute (www.lpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314,434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T32315718 TTH133-140 V05 GABLE 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:28 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-ogOijzl1 XIv7Rj56igwd9w5x_NGI6mUHz6p2UoyB?xn 4-6-8 9-1-0 4-6-8 4-6-8 Scale = 1:16.7 4x4 = 8 7 6 2x4 2x4 II 2x4 II 2x4 II 2x4 9-1-0 9-1-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.10 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.08 Vert(CT) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 5 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 30 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 9-1-0. (lb) - Max Horz 1=-43(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-127(LC 12), 6=-127(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7, 8, 6 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-142/301, 4-6=142/301 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft, B=45111; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-6-8, Exterior(2R) 4-6-8 to 7-6-8, Interior(1) 7-6-8 to 8-3-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces S MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) This item has been 8=127, 6=127. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any electronically signed and particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagnlu Velez PE No.68182 Meek loc. DBA N1Tek USA FL Cert 6634 16023 Srrlagley 1114o R& CYerlerrteld, NO 63017 Da1e: December 11.2023 WARNING - Verity design parameters and READ NOTES ON TMS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. ■ Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek* a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and proper damage. For general guidance regarding me 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrl" 1 Quality Criteria and SB-22 available from Truss Plate Institute (www.tpmst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314A34.1200 / MiTek-US.com Job Truss Truss Type City Ply T32315719 TTH133-140 V06 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, C d 2x4 2-6-8 5.Do �2 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 813:48:29 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-Gsy4wJmfl3l_2tglGORsh8e5_nZbrE7RCrYcOEyB?xm 5-1-0 2-6-8 3x6 = 2x4 Scale = 1:9.8 ro O 0-Q-10 5-1-0 0 0 5-M Plate Offsets (X,Y)-- [2:0-3-0,Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.15 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.26 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 13 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-11-13, 3=4-11-13 Max Horz 1=-21(LC 10) Max Uplift 1=-72(LC 12), 3=-72(LC 12) Max Grav 1=132(LC 1), 3=132(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-148/287, 2-3=-148/299 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuH=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft, L=3011t; eave=4ft; Cat. ll; Exp C; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any This item has been particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. JoagaW Velez PF. lve.69132 N17e1t lair. DRA INUTeh USA tL Cerr 6634 1602.1 Swlagley Ridge Rd. Chestrrfl.W. MO 63017 Date: December 11,2023 WARNING -Verily design parameters and READ NOTES ON TW S AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. i �� �a Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and ppropertrtyy dams gg . For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrP(1 Quality Criteria and guidance available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434,1200 / MiTek-US.com Job Truss Truss Type Qly Ply T32315720 TTH133-140 V07 GABLE 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, I d 7-3-12 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:30 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-k2WS8fmH3N9rg1 FVp5y5ELBHjBygagJaQV19YgyB?xl 4x4 = 3x4 - 16 15 14 13 12 11 10 3x4 Scale = 1:24.4 .g 0 14-7-8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.08 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.00 9 n/a n/a BCDL 10.0 Code FBC2020fTPI2014 Matrix-SH Weight: 64 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 14-7-8. (lb) - Max Horz 1=112(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 14, 15, 12, 11 except 16=146(LC 12), 10=-146(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 9, 13, 14, 15, 16, 12, 11, 10 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 7-3-12, Exterior(2R) 7-3-12 to 10-3-12, Interior(1) 10-3-12 to 13-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live Iliad shown covers rain loading requirements specific to the use of this truss component. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) 1, 9, 14, 15, 12, This item has been 11 except Qt=lb) 16=146, 10=146. 9) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any electronically signed and particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joryala Yenta PE N..68182 MTek lac DBA VDTek USA FL Cart 6634 1602,1 Swiedey Rifle Rd. CBesler6eld. MO 63017 Dale: December 11,2023 a WARNING -Verify design parameters and READ NOTES ON TNIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 1/2/2023 BEFORE USE. MiTek* Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTPl1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T32315721 TTH133-140 V08 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, d d 5-7-12 4x6 = 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:31 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-CF4rL?nvggHilBphNoTKn4NKaAFJ7zjf91 i57yB?xk 4 4x4 i 2x4 II 4x4 Scale = 1:20.1 .9 6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(CT) ri n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC20201TPI2014 Matrix-SH Weight: 37 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=11-2-8, 3=11-2-8, 4=11-2-8 Max Horz 1=-84(LC 10) Max Uplift 1=-104(LC 12), 3=104(LC 12), 4=-196(LC 12) Max Grav 1=169(LC 23), 3=169(LC 24), 4=411(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-251/355 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 5-7-12, Exterior(2R) 5-7-12 to 8-7-12, Interior(1) 8-7-12 to 10-7-15 zone, cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) This item has been 1=104, 3=104, 4=196. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any electronically signed and particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Josgaro Velea PE Ne.69132 .%BTek tac. DBA MTek USA FL L-1 6634 16O2J Swlyley RIdgt PA C6esteraeld. MO &M17 Darr: December 11,2023 O WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7471 rev. 1/2/2021 BEFORE USE. i �� �A Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damagge. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see A SVTP 1 Qualgy Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12DO l MTek-US.com Job Truss Truss Type city Ply T32315722 TTH133-140 V09 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:32 2023 Page 1 ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-gRdDZLoXb_PZvLOtxW?ZJm Gb0_aS2aVtupnGdZyB?xj 3-11-12 7-11-8 3-11-12 3-11-12 3x4 2x4 II 4x4 = 3x4 -- Scale = 1:14.6 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC20201TPI2014 CSI. TC 0.23 BC 0.32 WB 0.09 Matrix-SH DEFL. in (loc) I/deft Ud Vert(LL) n/a n/a 999 Vert(CT) n/a - n/a 999 Horz(CT) 0.00 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 25 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=7-10-8, 3=7-10-8, 4=7-10-8 Max Horz 1=56(LC 11) Max Uplift 1=-69(LC 12), 3=-69(LC 12), 4=-131(LC 12) Max Grav 1=113(LC 23), 3=113(LC 24), 4=275(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-4=-167/293 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vu1t=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 3-11-12, Exterior(2R) 3-11-12 to 6-11-12, Interior(1) 6-11-12 to 7-3-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=1b) This item has been 4=131. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any electronically signed and particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joyale %'elez PE Nr.681a2 MI[ek tec. DBAMiTek USA F1Cen6634 1602.1 Swings y RMBe Rd. C6n4r11e1d. Mo 63017 Dare; December 11,2023 a WARNING -Verity design parameters and READ NOTES ON TMS AND INCLUDED MITEK REFERENCE PAGE 10111-7473 rev. 1l2/2023 BEFORE USE. i �� �A Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP f Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponems.com) 314.434.12001 MiTek-US.com Job Truss Truss Type Qty Ply T32315723 TTH133-140 V10 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:33 2023 Page 1 ID tPuYCeVfQTfYt30C?ZvfnpzlGUH-9dBbmhp9MIYQXUz4VDWos_onCOx2n2607TWp9?yB?xi 2-3-12 4-7-8 2-3-12 r 2-3-12 3x6 = 2 2x4 i 2x4 Scale = 1:8.6 xd d o4s 4-7-0 Plate Offsets (X,Y)-- [2:0-3-0,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.23 Vert(CT) n/a n/a 999 8CLL 0.0 Rep Stress Incr YES WE 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SIP No.2 TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-6-8, 3=4-6-8 Max Horz 1=-28(LC 10) Max Uplift 1=-68(LC 12), 3=-68(LC 12) Max Grav 1=125(LC 1), 3=125(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=oft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joagele Velez PE N.Aa132 \Dick Lee. DBA 311Tek USA FL Cert 66J4 16OL1 Swladey Ridge Rd. Canlerfiel6, MO 63017 Date: December 11.2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. i �� �rn Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and pproperrtyry damage. For general guidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP 1 quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314,434.1200 / MiTek-US.com Job Truss Truss Type Qty Ply T32315724 TTH133-140 V11 Valley 1 1 Job Reference (optional) Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:34 2023 Page 1 ID:tPuYCeVfQTfYt30C?ZvfnpzlGUH-dglz_1 pn7bgH9eYG2x110BLylolXWU _AL7GMhRyB?xh 3-10-0 7-8-0 3-10-0 3-10-0 b d 3x4 2x4 11 4x4 = 3x4 Scale = 1:14.2 •d d 7-8-0 r 7-8-0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.15 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 23 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (size) 1=7-8-0, 3=7-8-0, 4=7-8-0 Max Horz 1=-35(LC 10) Max Uplift 1=-60(LC 12), 3=-60(LC 12), 4=-127(LC 12) Max Grav 1=102(LC 23), 3=102(LC 24), 4=258(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-4=-159/296 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=3011; eave=4ft; Cat. 11; Exp C; Encl., GCpi=O.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=lb) 4=127. This item has been 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code" electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaq,& Velez PF No.69192 MiTek tat. DBA MiTek USA FL Cer166d4 1607-t SwMgl#y Rtd;e Rd. Che ter6eld,.MO 63017 Date: December 11,2023 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. ■ Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTeke a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general gguidance regarding the 16023 Swingley Ridge Rd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314,434.1200 / MTek-US.com Symbols Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION 1/2 L Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-;1s' For 4 x 2 orientation, locate plates 0- ''16' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number/letter where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPl1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-22: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 3 Joint ID TOP CHORDS typ C1-2 C2-3 of WEBS c�4 4 0 m O M 0 ~ C7-8 C6-7 C5-6 0 BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. Product Code Approvals ICC-ES Reports: ESR-1988, ESR-2362, ESR-2685, ESR-3282 ESR-4722, ESL-1388 Design General Notes Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. 0 2023 MiTek® All Rights Reserved MOITeka MiTek Engineering Reference Sheet: MII-7473 rev. 1/2/2023 Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSUTPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/rPl 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19 % at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or pudins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/rPI 1 Quality Criteria. 21. The design does not take into account any dynamic or other loads other than those expressly stated.