FM by Honeywell Description REVIEW I)ATT: CITY OF ZE f' "t ! o' R I BUILDING OFFICI The Gamewell-FCI, S3 Series Intelligent Fire Alarm Control Panel provides the latest innovative high -end processing power. It offers a simple, intuitive solution for the small to mid -sized fire alarm applications. In standalone or network configurations, the S3 Series complies with most fire alarm application requirements. It supports either of the following types of networks. • Up to 64 nodes using the 7100 Series panel. • Up to 122 nodes using the S3 Series or E3 Series® panels. Use either twisted -pair wire or fiber-optic to network panels at a high-speed 625K baud ARCNET network bus. With flexible Boolean logic, intelligent detection, and Ether- net connectivity, this system provides power and versatility that surpasses comparable, small addressable fire alarm systems. The basic S3 Series consists of an SLP (Smart Loop Panel) main board, LCD-SLP touchscreen display, SLC loop personality modules, and 7 amp power supply. The SLP provides either one or two SLC loops in Class A or B configuration that supports either of the following protocols: • Up to 318 devices per loop using the System Sensor® protocol. If you add a second loop module, it increases the maximum device count to 636 devices. • Up to 126 devices per loop using the Apollo protocol. If you add a second loop module, it increases the maxi- mum device count to 252 devices. Four Class B or two Class A NACs can be wired and syn- chronized using the System Sensor, Cooper -Wheelock, or Gentex strobes. To retrofit the SLP on the existing audible/ visual appliances, the on -board Electronic EOL (EEOL) automatically adjusts to the EOL resistor in the field. A 4.3" (10.92 cm) color touchscreen display screen shows the following: • Events on the system • Status of analog addressable devices • Complete diagnostic fault codes/messages • Five programmable function buttons with LED status for accessibility to the following functions: - Disable/Enable - Trouble Acknowledge - Bypass Output - Alarm Acknowledge - Lamp Test - Custom -defined B Series® System Sensor® and FocalPoint®are registered trademarks of Honeywell Intptational Inc. UL is a registered trademark of Underwriters Laboratories Inc. - r ss 8-a"r1k' 01900rel Panel Small Analog Addressable Fire Alarm S3 Series Features Control Panel • Listed per ANSI/UL® Standard 864 9th Edition. • IBC Seismic Certified. • Allows one SLC loop (expandable to two loops) that supports either System Sensor or Apollo devices in Class A or Class B (Style 4, 6 or 7). • System Sensor supports up to 318 intelligent devices and each SLC loop supports the following. - up to 159 detectors. - up to 159 modules (expandable to 636 maximum per panel). • Apollo supports up to 126 intelligent detectors and modules per SLC. (Expandable to 252 maximum per panel). • Includes a high resolution (4.3") (10.92 cm) color touch - screen display. • Supports a network�system of up to 122 nodes (includes E3 Series panels) or up to 64 nodes (includes 7100 Series). • Provides 7.0 amp power supply (120VAC or 240VAC). • Includes four Class B or two Class A built-in Notification Appliance Circuits (NAC). Provides selectable System Sensor, Cooper -Wheelock, or Gentex strobe synchroni- zation. • Supports up to 32 serial annunciators (LCD, LED -only,' LED Switch). SIGNALING V� City or FM MEA Chicago LISTED FDNY: Approved ��•Mc S1869 APPROVED COA46162 7165-1703:0176 Class 1 Reference Certificate of Compliance VMA-45894-02C GAMEWELL-FCI 4a111111W. 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ,�2014 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60730 Rev. F page 1 of 4 / Application The S3 Series Fire Alarm and Life Safety System is an easy -to -use intelligent fire alarm solution designed for the small to mid -sized buildings. Analog technology delivers the benefits of a simple system installation, while a user- friendly interface makes panel operation and system main- tenance quick and intuitive. Smart Panel Programming Using Boolean logic programming, the installer may cus- tomize the system to precisely suit the needs of the build- ing owner. Auto -programming allows the installer to instantly locate all the devices on the SLC loop. Simple, Intuitive Display The front panel display provides a user-friendly interface for the operator's control. A 4.3" (10.922 cm) color touch - screen displays system status, event details and service modes. On the front of the panel, six LEDs show the follow- ing conditions. • Fire Silenced • Hazard (Gas or CO) AC Power • Supervisory Trouble Five custom programmable switches allow the user quick access to common functions specific to the building like device disable, output bypass and device status. Perfect for Retrofits The S3 Series is well -suited for retrofit applications. The SLP provides a simple way to upgrade your fire protection system. It is designed to be an upgrade solution for the leg- acy FCI 7100 and Gamewell 602 Series panels. An added feature is the SLP's EEOL. Using EEOL, the installers can automatically identify the EOL for existing audible/visual appliances. Flexibility for Future Growth The S3 Series can be expanded to add a second SLC loop without replacing the entire system. Using the RPT-E3- UTP Network Repeater, you can network up to 64 nodes (122 nodes with the ANX node expander) using either twisted -pair or fiber-optic. The built-in Ethernet port allows the connection to the Gamewell-FCI's FocalPoint Graphical Workstation. Features (Continued) • Offers an Ethernet port for programming, a variety of system reports, and a FocalPoint Graphic Workstation connectivity. • Provides two fully -programmable Form-C contacts for Fire, Trouble, and Supervisory. • TimeCap - Saves time and date up to 48 hours without any power or battery. • Automatically adjusts to any NAC End -of -Line Resistor (EOL) value (1k-55k ohm) for legacy audible/visual appliances. • Removable display can be used as a remote annunciator. • Suitable for pre -action deluge applications. Optional Accessories DACT-E3 - Dialer The Digital Alarm Communication Transmitter sends digital signals over telephone lines to the central station. It con- nects to the SLP through an RS-485 bus. Using the Con- tact ID format, the DACT-E3 provides a four -digit account code followed by the code/numbers listed below: • Three -digit Event Code • Two -digit Group Number • Three -digit Contact Number All codes are used to provide specific point identification. The DACT-E3 is compatible with digital alarm communica- tor receivers (DACRs) that receive the following signaling formats: • Contact ID SIA • 3+1 4+2 For more information, refer to the following data sheets: DACT-E3 Data Sheet, P/N: 9020-0610 FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 RPT-E3-UTP - Network Repeater Card The Network Repeater allows the SLP fire control panels to connect to the broadband network from remote locations. It connects to other networked units using unshielded, twisted -pair wiring. The RPT-E3-UTP is available with two add -on fiber modules: • FML-E3 connects to the network using either 62.5/125 micron multi -mode fiber. • FSL-E3 connects to the network using 9/125 micron single -mode fiber. Refer to the RPT-E3-UTP Data Sheet, P/N: 9020-0609. LCD-7100 - Remote Annunciator The Remote serial display features an 80-character dis- play. The LCD-7100 can be surface or flush -mounted on a standard 4-gang electrical box. You can use up to five LCD-7100 remote annunciators per SLP panel. For more information, refer to the LCD-7100 Data Sheet, P/N: 9020-0486. ASM-16 - Addressable Switch/LED Module There are 16 programmable switches available to perform any function the application requires. Each ASM-16 switch has 3 LEDs fully programmable in red, yellow, and green. These LEDs can be programmed to operate with a certain button press or operate independently as a status signal (e.g. ON, OFF, Activated, etc). Up to 16 ASM-16 modules can be connected to the SLP panel. For more information, refer to the ASM-16 Data Sheet, P/N: 9020-0554. ANU-48 - 48 LED Driver Unit The ANU-48 provides output for eight remote panel switches and 48 remote LEDs for use in a remotely located UL® Listed annunciator enclosure. Up to 16 ANU-48 mod- ules can be connected to the SLP panel. For more infor- mation, refer to the ANU-48 Data Sheet, P/N: 9020-0596. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60730 Rev. F page 2 of 4 www.gamewell-fci.com Figure 2 illustrates the SLP-BB Cabinet Enclosure. Specifications SL OL Figure 2 SLP Enclosure Supports up to 636 Velociti devices or 252 XP95 devices DNR g [eDoc! MCS-COF D Detector Firg/Ca rDon MonoxId, Delector ASD-PL2F ASD-LS Relay Module LCD-7100 LCD-SLP Rem—Annunicato! Color ToucM1zcreer ASM-16 ANU-48 LED Switch Control LED Display Driver 1/8"H D Device Loops Up to two Class A or B, System Sensor units, each loop supporting up to 318 device addresses. Or - Apollo units, each loop supporting up to 126 device addresses per loop. NAC circuits 4 Class B or 2 Class A (2.0 A each circuit), 6.0 A total NAC Operating Voltage 24 VDC NAC Minimum Voltage 19.5 VDC @ 20.4 V battery voltage SLC Loop Circuit Operating Voltage 24 V peak -to -peak Input Voltage 120 VAC, 60 Hz 240 VAC 50-60 Hz Input Current 120 VAC, 2.75 amps max. 240 VAC, 1.4 amps max. Aux Power 1 (Continuous) 24 VDC nominal at 1.OA Aux Power 2 (Resettable) 24 VDC nominal at 1.OA Base Panel Current draw Standby: 0.111 amps Alarm: 0.243 amps Operating Temperature 32°-120° F (0°-49° C) Relative Humidity 93% (non -condensing) Battery Charger Voltage +24 VDC Battery Charger 55 A/H batteries (cabinet Capacity accommodates 12 A/H batteries) Alarm, Trouble & Supervisory Relay Contacts Form-C, 2 amps @ 24VDC (resistive) Cabinet Dimensions: SLP-BB Dimensions 14 112" W x 20 1/8" H x 4 1/2" D (36.83 W x 51.18 H x 11.43 D cm) S3BB-RB Dimensions 19 3/8" W x 19 3/8" H x 4.5" D (49.22 W x 49.22 H x 11.43 D) S3 Series Fire Alarm Control Panel Networkable up to 122 panels using twisted pair wire or fiber optics. I xr. Laptop Programming Figure 3 SLP Panel Configuration GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA e Tel: (203) 484-7161 e Fax: (203) 484-7118 www.gamewell-fci.com 9021-60730 Rev. F page 3 of 4 J 7 Ordering Information Part Number Description SLP-BLK SLP addressable FACP in black SLP-BB enclosure. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLP-RED SLP addressable FACP with red door and black SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLP-RED-G SLP addressable FACP 240VAC power supply with red door and black SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLC-PM System Sensor Loop Card -1 loop used for 159 sensors and 159 modules. For use with the SLP-E3 panels only. SLC95-PM Apollo Loop Card-1 loop used for 126 sensors and modules. For use with the SLP-E3 panels only. Ordering Information (Continued) Part Number Description Accessories DACT-E3 Digital Dialer Communicator Transmitter for the S3 or E3 Series. LCD-SLP LCD Color Touchscreen display with five programmable switches. For use with the S3 Series panels. Remote annunciation requires the E3 Series A2 cabinet. (E366-BA2, E3BB-RA2) RPT-E3-UTP Network repeater card with twisted - pair fiber connections require either an FML-E3 or an FSL-E3 card. FML-E3 Multi -mode fiber-optic card for one channel on the RPT-E3-UTP. FSL-E3 Single -mode fiber-optic card for one channel on the RPT-E3-UTP. SLP-RB SLP motherboard For use with the replacement or the retrofit solutions. FLPS-7-RB SLP 120VAC 7A power supply. For use with the replacement or the retrofit solutions. SLP-RETROFIT SLP Retrofit Kit for the 7100 B-Slim and IF602 panels. Includes the new door and the mount- ing plate. Requires the following: • SLP-RB • LCD-SLP • SLC-PM/ • FLPS-7-RB SLC95-PM S3613-1113 SLP red cabinet with an inner door for the mounting display behind the plexiglass. Requires the following: • SLP-RB • LCD-SLP • SLC-PM/ • FLPS-7-RB SLC95-PM LCD-7100 Remote Serial LCD Annunciator ASM-16 Remote Programmable Addressable Switch/LED Module ANU-48 Remote LED Driver Module GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 \9021-60730 Rev. F page 4 of 4 www.gamewell-fci.com II FIRE CONTROL INSTRUMENTS by Honeywell Description The Digital Alarm Communicator Transmitter (DACT-E3) is an optional component of the E3 Series® Expandable Emergency Evacuation System. The DACT-E3 sends digi- tal signals over the telephone network to a central station. This module can be located in the main cabinet or remotely located via a local RS-485 serial interface. The DACT-E3 is compatible with digital alarm communica- tor receivers (DACRs) that receive the following signaling formats: • SIA DC8 3+1 2300 Hz • SIA DCS20 4+2 1400 Hz • Ademco Contact ID 4+2 2300 Hz • 3+1 1400 Hz In addition to the DACT-E3 being compatible with digital signaling formats, the DACT-E3 features numerous for- mats for communication to a central station. As a digital communicator, the DACT-E3 complies with FCC Part 8, Telecommunication Standards for DC and AC Ringer Equivalence. Installation Instructions The DACT-E3 is adaptable for installation in standard E3 Series° System cabinets. Typically, the DACT-E3 module mounts on standoffs on top of the left side of the ILI-MB- E3/ILI95-MB-E3 module. Either unit can be easily con- nected to the backbox or sub -assembly plate depending on the cabinet module. Note: For instructions on installing the DACT-E3, refer to the E3 Series® Expandable Emergency Evacuation Instal- lation/Operation Manual, Part Number: 9020-0574 or the DACT-E3 Installation Instructions Part Number:9000-0581. Specifications Operating Voltage: 24 VDC (from the PM-9/PM-9G power supply) Operating Current: 0.018 amp Alarm Current: 0.018 amp Operating Temperature: 32' to 120' F (0 to 490 C) Relative Humidity: 0 to 93%O, non -condensing at 90° F (32° C) E3 Serieso and NetSOLO" are registered trademarks of Honeywell International Inc. UL@ is a registered trademark of Underwriters Laboratories Inc. BACTmE3 Digital Alarm Communicator Transmitter DACT-E3 Features • Listed under UL® Standard 864, 9th Edition • Communicates with the E3, ILI-MB-E3/ILI95-MB-E3 sub -assembly via RS-485 • Communicates in a variety of formats (including full Contact ID) • Transmits and verifies data to the central station • Offers pre-programmed dialing to the central station phone number • Performs on and off -hook status to the phone lines • Traces proper central station "ACK" and "Kiss -off' tone • Activates hang-up and release phone lines • Compatible with the IPDACT Internet Communicator Ordering Information Part Number Description DACT-E3 Digital alarm communicator transmitter An ISO 9001-2000 Company SIGNALING U� FM 3, P ciry"r MEA cn city m LISTED arvR . Approved Approved Denver s1869 3025415 FDNY: 7165-1703:0125 0, 1 Approved COA N6077 CI-2 High R, GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice, No responsibility is assumed by Gamewell-FCI for their use. ©2011 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0610 Rev. I page 1 of 1 Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI, Remote Alphanumeric Annunciator (RAN-7100) display is a remote annunciator. This adapt- able remote display can be used for installations in the fol- lowing modular systems. • E3 Series® Expandable Emergency Evacuation System • S3 Series Small Addressable Fire Alarm Control Panel • 7100 Series System It features an 80-character display which duplicates all the information on the main display with the exception of the menus. The 7100, E3 Series, and S3 Series control panels can accommodate up to five remote RAN-7100 annuncia- tors. In addition, the RAN-7100 can be surface or flush - mounted in the RAN-7100 backbox and installed 3,000 feet (914.4 m) away from the main control panel. The RAN- 7100 is also a retrofit solution for the Gamewell Legacy RAN-7100 annunciators. This feature offers you the option to use the RAN-7100 to upgrade to a 7100, an E3 Series or an S3 Series System. The RAN-7100 contains the following function keys • Alarm Acknowledge System Reset/Lamp Test • Trouble Acknowledge System Drill Test • Signal Silence A keylock must be placed in the "ON" position to enable the function keys with the exception of the "Trouble Acknowledge" key which is used to silence the trouble sounder on the RAN-7100. The LEDs on the RAN-7100 are listed as follows: • Alarm System Silenced • Supervisory NAC #1 Silenced • System Trouble NAC #2 Silenced • Power Fault Installation The RAN-7100 can be surface or flush -mounted on a stan- dard four -gang electrical box and installed up to 3,000 feet (914.4 m) away from the main control panel. Specifications Operating Voltage: 24 VDC (nominal) Supervisory Current: .012 amp Alarm Current: .023 amp Absolute Maximum Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 0 to 93% max., non -con- densing at 90° F (32° C) Dimensions: 10" W x 5 1/4" H x 2 7/16" D (25.4 W x 13.3 H x 6.9 D cm) E3 Series® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. Remote Alphanumeric Annunciator Features • Listed under UL® Standard 864, 9th Edition. • Includes an 80-character alphanumeric LCD display. • Provides a full complement of function keys and LEDs. • Installs in a remote location up to 3,000 feet (914.4 m) away from the main control panel. • Up to five annunciators can be used with the 7100, E3 Series and S3 Series panels. • Connects as a surface or flush -mount in the RAN2-BB backbox. • Designed for retrofitting Gamewell RAN annunciators to be installed in the 7100 Series, E3 Series or S3 Series Systems. • Offers a compact, attractive design. Ordering Information Part Number Description RAN-7100 Remote Serial LCD Display GWRAN2-BB Surface or flush backbox for RAN-7100 SIGNALING LISTED I S1689 7165-1703:0125 DSO 9001 ������� .�.*E■�� GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell international Inc. All rights reserved. www.gamewell-fci.com 9021-60693 Rev. D page 1 of 1 Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- cuit (NAC) expansion panel designed to extend the power capabilities of existing NACs and provide power for the auxiliary devices. The HPFF8 connects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. The HPFF8 is available in 8.0 amps. It provides regulated and filtered 24VDC power to each of the four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each (the total output cannot exceed 8.0 amps). The auxil- iary output is rated at 2.0 amps. This output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calcula- tions. The NAC outputs may be configured as any of the follow- ing: • Four Class B (Style Y) • Two Class A (Style Z) • Two Class B and one Class A • Four Class A with the optional HPP31076 Class A adapter installed These power supplies contain an internal Battery charger capable of charging up to 26.0 amp -hour (AH) batteries. The HPFF8 is mounted in lockable wall cabinet units that can accommodate up to two (2), 18AH batteries. A multi - pack option allows for up to four chassis mount units installed in a single lockable SBB-D4 enclosure. These chassis mount units have a "CM" suffix, HPFF8CM and can accommodate two 12AH batteries. Power supplies are available in either 120VAC/60 Hz or 240VAC/50 Hz. One of the most challenging aspects of a retrofit applica- tion is locating the existing End -of -Line (EOL) resistor. In these applications that have EOL values, other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds the installation and the system checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. NPFF8 NAC Expander/Power Supply HPFF8 Features • Four (4) supervised notification application circuits (NACs) capable of supplying +24VDC at 3.0 amp maximum each • NAC output circuits may be configured as any of the following: - Four Class B (Style Y) - Two Class B & one Class A - Two Class A (Style Z) - Four Class A with the optional HPP31076 Class A adapter installed • Four field -programmable operational modes • 2.0 amp auxiliary continuously supplied output • Two (2) fully supervised input/output control circuits • Temporal coding and sync protocols compatible with the following notification appliance brands: - System Sensor - Faraday - Gamewell - Amseco - Cooper -Wheelock - Gentex • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults • Trouble indication for supervision of the following: - NAC circuits - Auxiliary output - AC input - Charger - Battery voltage - Open contacts in the initiat- - Earth ground faults by ing device signal inputs (for individual status LED's FACP trouble notification) • Separate Trouble and AC Fail Form-C relay Contacts An ISO 9001-2000 Company SIGNALJNG LISTED FM Y$1 S24562 naaROvEo 7315-1637:0102 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60521 Rev. B page 1 of 2 Features (Continued) • The Trouble Form-C relay contacts selectable for imme- diate or a 2 hour delay with AC failure • 26 AH battery charger capability; the wall cabinet supports two 12V 18AH batteries, while the multi -pack equipment cabinets supports two 12V 12AH batteries. • NAC Overload protection and indication • Up to four chassis mount units (HPFF8CM) can be installed in the SBB-134 backbox • Wall mount units can be configured to internally house the following: - one AOM-2SF single control module - one AOM-2R single relay module Specifications Primary Input Power: 120VAC/6OHz, 3.6A or 220VAC/5OHz, 1.5A Secondary Power: 24 volt operation: two (2), 7-24 AH batteries Battery Charging Capacity: Up to 26 AH batteries mounted Battery Space: HPFF8 Cabinet: SBB-D4 Cabinet: Total Output Power: Standby Current: Auxiliary Power Output: Up to two 18AH batteries Up to two 12AH batteries per supply 8.OA max 0.030 A 0.15A under all conditions 2.OA if load is removed dur- ing operation (external relay or AC Fail Relay is required) Specifications (Continued) NAC Output Ratings: 24VDC fully regulated, 3.OA max per circuit (8.OA total) End -of -Line Resistor 2K to 25k ohm,'/ watt Range: Common Trouble Relay/AC Fall Relay: 2.OA at 28VDC or 120VAC Input Control Circuit: 16-30VDC @ 5mA min. Temperature Rating: 32°F to 120°F (0°C to 49°C Relative Humidity: 10% to 93% non -condensing Cabinet Dimensions: HPFF8 Cabinet: 16.65" W x 19.0" H x 5.2° D (42.29 W x 48.26 H 13.23 D cm) SBB-D4 Cabinet: 24" W x 45.9" H x 5.15" D (60.96 W x 116.52 H x 13.1 D cm) Ordering Information Part Number Description HPFF8 8A fire rated power supply operating at 120VAC/60 Hz. Unit includes red enclosure with HPP lock and key HPFF8CM 8A fire rated power supply - chassis mounted operating at 120VAC/60 Hz. Unit includes mounting hardware for installation in the S1313-134 enclosure HPFF8E 8A fire rated power supply operating at 240VAC/50 Hz HPFF8CME 8A fire rated power supply chassis mounted operating at 240VAC/50 Hz HPP31076 Class A (Style Z) NAC module FCI-VDR-D4 Vented door, PK-625 lock and key for SBB-D4 backbox, black SBB-D4 Backbox, accepts up to 4 chassis, black GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60521 Rev. B page 2 of 2 www.gamewell-fci.com MS-1 Series FIRE CONTROL INSTRUMENTS by Honeywell Description Non -Coded, Manual The Gamewell-FCI, MS-7 Series manual fire alarm sta- tions are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All stations have a key lock/reset which is keyed alike with Gamewell-FCI fire alarm control panels and other manual fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a dou- ble action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.` The sta- tion features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a single action station designed for installation in the signal- ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.' The sta- tion features screw terminals. The Velociti® Series stations use a communication proto- col that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Fire Alarm Stations MS-7 Features • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any LILO Listed control panel • Both single and double action stations available • Tumbler lock for test and reset keyed alike with Gamewell-FCI controls • Surface or semi -flush mounting • Shock and vibration resistant • Stations (MS-7LOB) Listed for outdoor applications • Complies with ADA pull force requirements "Only the red LED is operative in panels that do not oper- ate in Velociti mode. SIGNALING -�---� �L FM EA LISTED APPROVED Approved 4Y S2465 3023594 67.02-E VOI.Vill 7150-1703:0119 7150-1703:0170 7150-1703:0109 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0616 Rev. E page 1 of 2 MS-7S Single Action Station The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action station similar to the MS-7 station, with the additional feature of both English and Spanish instructions molded into the unit. MS-7LR Dual -action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals for connection to an ini- tiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabil- ities are required. It consists of an MS-7LR mounted on a plate with an abort switch and LED indicators for system normal, and system activated status. MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-1/0 backbox. In retrofit applications, the station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior stations may be surface mounted or semi -flush mounted on a standard double -gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi -flush mounting. NYC -Plate The NYC -Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC -Plate Specifications Material: Lexan® Contact Ratings: 0.25 amps. @ 30 VACNDC (resistive) Dimensions: 5 5/8" H x 4 1/4" W x 1 1/4" D (14x10.1x3.2cm) Operating Temperature (MS-7AF, MS-7ASF): 32° to 120° F (0° to 49° C) (MS-7LOB): -30° to 150° F (-35° to 66' C) Relative Humidity (MS-7AF, MS-7ASF): 10 to 93% (non -condensing) (MS-7LOB): 85% ± 5% @ 86' ± 3.6° (30' ± 2° C) Alarm Current: .0030 amp. 0.007 for LED Supervisory Current (MS-7AF, MS-7ASF): .00030 amps. Ordering Information Part Number Description MS-7 Double action station MS-7AF— Velociti addressable double action station MS-7ASF** Velociti addressable single action station MS-7S Single action station, wire leads MS-7SP Double action station, English and Spanish instructions MS-7LR Agent release station, dual -action MS-7LRA Agent release station with abort switch, LED indicators, dual- action MS-7LOB Double action station, outdoor use (Includes SB-1/0 - Indoor/outdoor use backbox) SB-1/0 Indoor/outdoor use backbackbox SBA Surface backbox BG12TR Trim ring for semi -flush mount, plastic NY -PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0616 Rev. E page 2 of 2 www.gamewell-fci.com by Honeywell Description The Gamewell-FCI Velociti• Series, addressable monitor module AMM-21F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end -of -line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell- FCI addressable series fire alarm control panel. Any initiating device with normally open (N.O.) dry con- tacts may be made addressable when connected to the AMM-21F module. The Velociti• Series use a communication protocol that substantially increases the speed of communi- cation between the sensors and certain Gamewell- FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-21F module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, ple- num detector, waterflow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possi- ble to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-21F can sup- port a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Veloce is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. vememOseries MNIIIIIIII12F Addressable Monitor Module AMM-2F Features Compact size allows easy installation • Class B, Style B, initiating circuit • 40 Ohm line resistance for each initiating device circuit • Connects to any normally open dry contact device Specifications Supervisory Current: .000375 amps Alarm Current: .00060 amps Operating Temperature: 320 to 1200 F (00 to 490 C) Relative Humidity: 10 to 93% (non -condensing) End -of -Line Resistance: 47K ohms Dimensions: 1.3" L x 2.5" W x 0.5" D (3.3 x 6.4 x 1.3 cm) Ordering Information Part Number Description AMM-2F Addressable monitor module, single circuit, Style B, Class B SIGNALING @ MEA LISTED O APPr-ved SLIM 3023M4 W-MVOLN 73MIM:0102 s;'CRrPf20 :: GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA - Tel: (203) 484-7161 - Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 02013 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0626 Rev. E page 1 of 1 Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series addressable output supervised control module (AOM-2SF) allows a Gamewell-FCI analog addressable fire alarm control panel to switch an external power supply, such as a DC supply or audio amplifier (up to 80 VRMs) to notification appliances. The AOM-2SF notification appliance circuit can be wired either Class A (Style Z) or Class B (Style Y). It also super- vises the wiring to the connected loads and reports their status to the panel as NORMAL, OPEN or SHORT CIRCUIT. The module contains a panel controlled LED. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI ana- log addressable fire alarm control panels. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net result is a superior response speed up to five times greater than the earlier designs. The AOM-2SF module is designed for installation in the signaling line circuit of any Gamewell-FCI analog address- able fire alarm control panel. The signaling line circuits of Gamewell-FCI analog addressable fire alarm control pan- els are designed to accommodate up to 159 modules per circuit. The AOM-2SF is designed to mount in a 4" (10.16 cm) square junction box 2 1/8" (5.5 cm) deep. Table 1 lists the relay contact ratings. Current Rating Maximum Voltage Load Description Application 3A 30 VDC Resistive Non -Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non -Coded 0.5A 125 VAC Resistive Non -Coded 0.5A 30 VDC Inductive (UR=5ms) Coded 1A 30 VDC Inductive (L/R=2ms) Coded 0.5A 125 VAC Inductive (PF=.35) Non -Coded 0.7A 75 VAC Inductive Non -Coded Table 1: Relay Contact Ratings Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. VelocitiO Series A8111=2SF Addressable Output Relay Supervised Control Module AOM-2SF Features • Listed under ULO Standard 864 and UL2572 for Mass Notification. • Designed as a compact size to allow easy installation. • Includes Class A, Style Z, or Class B, Style Y notification appliance circuit. • Accommodates audio amplifiers up to 80 VRMs. • FM Listed as suitable for a releasing device service. • Includes a bicolor LED that flashes green whenever the module is addressed, and lights steady red upon activation. *Note: Only the red LED is operative in panels that do not operate in Velociti® mode. Specifications Supervisory Current: Alarm Current: Operating Temperature Relative Humidity: Dimensions .000375 amps .0065 amps 32' to 120' F (0' to 49' C) 10 to 93% relative humidity (non -condensing) 4 1/2" H x 4" W x 1 1/4" D (11A H x 10.2 W x 3.2 D cm) Ordering Information Part Number Description AOM-2SF Addressable output supervised control module SIGNALING &L FM MEA LISTED moo. APProv, S1949 3023594 227-03•EVoI.IV 7300-1703:0102 I IS090011 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA - Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2014Honeywelllntemationallnc. Allrghtsreserved. www.gamewell-fci.com 9020-0627 Rev. G page 1 of 1 Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- tion provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor's address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed -tem- perature thermal sensing on the ASD-PTL2F model. The Velociti® Series use a communication protocol that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concen- trates on the single device. The net effect is a response speed up to five times greater than earlier designs. Ordering Information Part Number Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when the remote test is required. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. V910cmeseries ASIMPL2FP ASB=P'FL2F and AS1=PL2F1 Analog, Addressable Photoelectronic ASD-PL2F/ASD-PTL2F Features Smoke Sensor ASD-PL2FR • Sleek, low -profile design. • Visual rotary, decimal switch addressing (01-159). • Built-in functional test switch activated by an external magnet. • Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm." • Optional relay, isolator, or sounder bases. • Low standby current. • Analog addressable communication. • Stable communication technique with noise immunity. • Optional remote, single -gang LED Indicator (RA100Z). • Compatible with Gamewell-FCI analog addressable panels. Note: `Only the red LED is operative in panels that do not operate in Velociti mode. SIGNALING L FM MEA , Approved LISTED APPROVED FDNY $_4 S1913 3023594 COA #:219-02-E 7272-1703:0121 VoI.VI GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0617 Rev. J page 1 of 2 Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: • 4.0" (10.2 cm) square box. • 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. • Single -gang box (except relay or isolator bases). • With B200S or B200SR base, mounted on a 4.0" (10.2 cm) octagonal or square box. • With B224RB or 1322461 base, mounted on a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end -of -line resistors are not required. Wiring "T taps" or branches are permitted for Style 4 (Class "B") wiring. Sensor Spacing Gamewell-FCI recommends that the spacing sensors be used in compliance with NFPA 72. Specifications ASD-PL2F, ASD-PTL2F, ASD-PL2FR: Dimensions: 2.1" (5.1 cm) height Diameter: 4.1" (10.4 cm) installed in the B501 base 6.1" (15.5 cm) installed in the B21OLP base Shipping Weight: 5.2 oz. (147 g) Operating ASD-PL2F: Temperature: 32° F to 120` F (0` C to 49° C) ASD-PTL2F: 32° F to 100• F (0° C to 38° C) UL®-Listed 0-4000 ft./min. (1,219.2 m/min.), Velocity Range: suitable for installation in ducts. Relative Humidity: 10-93% (non -condensing) Thermal Ratings: Fixed -temperature setpoint 135° F (57° C) Electrical Specifications Voltage Range: 15 - 32 volts DC peak Standby Current: (max. avg.)-. .0003 A @ 24 VDC (One communication every 5 seconds with LED blink enabled). Maximum Alarm - Current: .0065 A @ 24 VDC (LED) lit). Bases and Options B501 Plug-in sensor base without flange Dimensions: 4.1" (10.4 cm) diameter B21OLP Flanged mounting base Dimensions: 6.1" (15.5 cm) diameter B21OLPBP Flanged mounting base bulk pack Dimensions: 6.1" (15.5 cm) diameter B224RB Plug-in sensor base with auxiliary Relay Base relay, SPDT, rated 2 amps @ 30 VDC (resistive). Screw terminals: Up to 14 AWG (2.0 mmz) 2 coil latching relay 1 Form C contact UUCSA Rating: 0.9 A @ 125 VAC, inductive 0.9 A @ 110 VDC, inductive 3 A @ 30 VDC, resistive Dimensions: 6.1" (15.5 cm) diameter Maximum: 25 devices between isolator bases. B200S Intelligent sensor sounder base Dimensions: 6.875" (17.5 cm) diameter B200SR Standard sounder base, UL 8649th Edition compliant, ULC Listed Dimensions: 6.875" (17.5 cm) diameter RA10OZ Remote LED Annunciator BCK-200 Black detector covers (box of 10) DNR Duct smoke housing GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0617 Rev. J page 2 of 2 www.gamewell-fci.com 2� Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series, addressable plug-in thermal sensors with integral communication provide fea- tures that surpass conventional sensors. Point ID capabil- ity allows each sensor's address to be set, providing exact locations for pinpointing alarm locations and for selective maintenance. ATD thermal sensors use an innovative thermistor sensing circuit to produce 135°F/57°C fixed - temperature (ATD-L2F). The ATD-RL2F provides a combi- nation 15'/minute rate -of -rise with 135' fixed thermal detection that is included in a low -profile package. The ATD-HL2F provides fixed high -temperature detection at 190°F/88°C. These thermal sensors provide cost-effective, addressable property protection in a variety of applica- tions. The Velociti® Series uses a communication protocol that substantially increases the speed of communication between the sensors and Gamewell-FCI analog address- able fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and identifies the single device with the status change. The net effect is response speed up to five times greater than earlier designs. Installation ATD plug-in sensors use a separate base to simplify instal- lation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: • 4.0" (10.2 cm) square box. • 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. • Single -gang box (except relay or isolator base). • With B200S or B200SR base, mounted on a 4.0" (10.2 cm) octagonal or square box. With B224RB or B224BI base, mounted on a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end -of -line resistors are not required. Wiring "- taps" or branches are permitted for Style 4 (Class "B") wiring. Velociti® and E3 Seriese are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. ULC® is a registered trademark of Underwriters Laboratories Canada Inc. velocitio Series ffl=Lff, AT1=1L2F Addressable Thermal Sensor ATD-L2F Features • Sleek, low -profile design • Visual rotary switch addressing • Built-in functional test switch activated by an external magnet • Bicolor LEDs flash green whenever the sensor is addressed, and light steadily red on alarm* • Optional relay, isolator, or sounder bases • Low standby current • Addressable communication • Stable communication technique with noise immunity • Optional remote, single -gang LED accessory (RA-100Z) • Suitable for installation in ducts Note: *Only the red LED is operative in panels that do not operate in Velociti° mode. An ISO 9001-2000 Company SIGNALING U FM M EA �O O A& v r LISTED APPROVED Approved S2332 3023594 219.02-E Vol.VI 7270.1703:0115 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2011 by Honeywell Intemabonal Inc. All rights reserved. www.gamewell-fci.com 9020-0620 Rev. E page 1 of 2 Specifications ATD-L2F/ATD-RL2F Dimensions: Shipping Weight: Operating Temperature: ATD-L2F or ATD-RL2F ATD-HL2 Sensor Spacing: Relative Humidity ATD-L2F ATD-RL2F ATD-HL2F 2.1" (5.3 cm) Height 4.1" (10.4 cm) diameter installed in the B501 base 6.1" (15.5 cm) diameter installed in the B21 OLP base 4.8 oz. (137 g) -4° F to 100- F (-20° C to 38-C) -4° F to 150°F (-20 C to 66°C) ULe approved for 50 ft. (15.2 m) center to center FM approved for 25 x 25 ft. (7.6 x 7.6 m) spacing 10 - 93% (non -condensing) Fixed -temperature setpoint 135-F (57°C) Combination 135° F fixed temperature and 15° F(8.3°c)/per minute rate -of -rise* Fixed -temperature setpoint 190-F(88°C) Electrical Specifications Voltage Range: 15 - 32 Volts DC peak Standby Current: 200 mA @ 24 VDC (without communication) (max. avg.) .0003 A @ 24 VDC (one communication every 5 seconds with LED blink enabled) LED Current (max.) .0065 A @ 24 VDC (LED lit) Specifications Bases and Options B501 Plug-in sensor base without flange Dimensions: 4.1" (10.4 cm) diameter B21OLP Flanged mounting base Dimensions: 6.1" (15.5 cm) diameter B21OLPBP Flanged mounting base bulk pack Dimensions: 6.1" (15.5 cm) diameter B224RB Plug-in sensor base with auxiliary relay, SPDT 2 coil latching relay 1 Form C contact UL/ CSA Rating: 0.9 A @ 125 VAC (inductive) 0.9 @ 110 VDC (inductive) 3.A @ 30 VDC (resistive) Dimensions: 6.1" (15.5 cm) diameter B224BI Plug-in sensor isolator base for Style 7 operation Dimensions: 6.1" (15.5 cm) diameter Maximum 25 devices between isolator bases B200S Intelligent sensor sounder base Dimensions: 6.875" (17.5 cm) diameter B200SR Standard sounder base, UL 864 9th Edition compliant, ULC Listed Dimensions: 6.875" (17.5 cm) diameter RA-100Z Remote LED Annunciator BCK-200 Black detector covers (box of 10) Ordering Information Part Number Description ATD-L2F Addressable thermal sensor, fixed, 135° F ATD-RL2F Addressable thermal sensor, combination fixed,135° F and 15°/minute rate -of -rise. ATD-HL2F Addressable thermal sensor, fixed, 190' F GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 �9020-0620 Rev. E page 2 of 2 www.gamewell-fci.com 'I'Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series, addressable output relay control module (AOM-2RF) allows a Gamewell-FCI analog addressable fire alarm control panel to switch dis- crete relay contacts by code command. The relay provides two isolated sets of Form-C contacts which transfer simul- taneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI ana- log addressable fire alarm control panels. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net result produces a superior response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any Gamewell-FCI analog address- able fire alarm control panel. The module contains a panel controlled LED. The AOM-2RF is designed to mount in a 4" (10.16 cm) square junction box 2 1/8" (5.53 cm) deep. Table 1 lists the relay contact ratings. Current Rating Maximum Voltage Load Description Application esls Ive on Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non -Coded 0.5A 125 VAC Resistive Non -Coded 0.5A 30 VDC Inductive (L/R=5ms) Coded 1A 30 VDC Inductive (L/R=2ms) Coded 0.5A 125 VAC Inductive (PF=.35) Non -Coded 0.7A 75 VAC Inductive Non -Coded Table 1: Relay Contact Ratings UL® is a registered trademark of Underwriter's Laboratories Inc. Velociti® Series is a registered trademark of Honeywell International Inc. voinitiO Series A0111=21F Addressable Output Relay Control Module AOM-2RF Features • Listed under ULO Standard 864. • Offers two sets of Form "C" contacts. • Provides visual rotary, decimal switch addressing (01-159). • Includes a bicolor LED that flashes green whenever the module is addressed, and lights steady red upon activation." • Designed as a compact size to allow easy installation. Note: Only the red LED is operative in panels that do not operate in Velociti mode. Specifications Supervisory current: Alarm current: Operating temperature Relative humidity: Dimensions: .000375 amps. .0065 amps. 32° to 120° F (0° to 49° C) 10 to 93% relative humidity (non -condensing) 4 1 /2" H x 4" W x 1 1 /4" (11.4 x 10.2 x 3.2 cm) Ordering Information Part Number Description AOM-2RF Addressable output relay control module SIGNALING & <FM> MC w l LISTED _.wD Appmved S1913 3023594 219-02-E Vol. VI 7300-1703:0102 IS0900111 GAMEWELL-FCI 1 „�T; „" �1,� 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 1 ©2014 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0625 Rev. F page 1 of 1 CABLE SPECIFICATIONS All specifications referenced are nominal measurements unless otherwise noted. SMARTWIRE ; 7 O G Y� SMARTWIRE-" .:.... Avg% IF 6789 All specifications referenced are nominal measurements unless otherwise noted. DTK-HW Series AT Equipment Pane//Dedicated Circuit Surge Protective Device Genera/ Product Specifications DITEK's HW series of surge protectors are designed and manufactured to meet the exacting standards of the life safety industry. These compact parallel mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit loads. DTK-120HW DTK-120/240HW Product Features • Available for Popular 120V and 120/240V systems • DTK-120HW approved for 20A circuit breakers • Diagnostic LED indicates ground presence, system power and SPD function • Weatherproof enclosure • Small footprint enables installation in a variety of locations • Available for popular 120V, and 120/240V systems • Complies with ANSI/IEEE C62.41 and C62.45 Category B standards • Ten Year Limited Warranty X Specifications Agency Approvals: UL 1449, 3rd Edition, cUL IEEE Location Category: Category B Protector Type: SPD Type 2 Protection Modes: L-G, L-N, N-G Response Time: <1 ns Temperature Range: -40OF — 1850F (-40°C — 85°C) Maximum Humidity: 95% non -condensing Operating Frequency: OHz — 40OHz Dimensions: 2.93" x 2.83" x 1.68" (74.4mm x 71.9mm x 42.7mm) Connection: V diameter threaded fitting Weight:.51b. (227g) Housing: ABS Model Peak UL 1449, 3rd Short Circuit UL1449, Selection: Service Wiring Surge MCOV Ed. V.P.R. Current V Ed. I„ DTK- Current Rating Rating Single 0 700V L-N, L-G; 120HW 19,500A 130V 10,000A 3,000A (2W + G), 120VAC 600V N-G 13,000A/ 700V L-N, L-G; Split (P Phase 120/240HW 130/260V 600V N-G; 10,000A 3,000A (3W + G), 120/240VAC 6,500A/ Mode 1200V L-L One DITEK Center 1-800-753-2345 1720 Starkey Road Technical Support: 1-888-472-6100 Largo, FL 33771 www.ditekcorp.com CI&US Document: SPS-100057-001 Rev 10 9/13 ©2013 DITEK Corp. Specification Subject to Change SYSTEM SENSOR" Selectable -Output Low Frequency Sounder and Low Frequency Sounder Strobes for Wall Applications SpectrAlert° Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features • 520 Hz t 10% square wave tone • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Field -selectable candela settings on wall units: 135, 150, 177, and 185 • Rotary switch for low frequency sounder tone • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert devices • Compatible with MDL3 sync module • Listed for ceiling or wall mounting s. f r o m S s k a m S e n s o r The SpectrAlert Advance series offers the most versatile and easy -to -use line of low frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, dual listed for wall and ceiling mounting, SpectrAlert Advance can meet virtually any application requirement. The wall -mount low frequency sounder, and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that operates within frequency range of 520 Hz t 10% and is of a square wave tone. Like the entire SpectrAlert Advance product line they include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, Agency Listings automatic selection of 12- or 24-volt operation, and a rotary switch for 520 Hz low frequency sounder tones. sicMAuxs @ <jM�>MEA I.h7TEO APPROVED approved S4011(sounder) 3047563 MEA452-05-E 7135-1653:0223 S5512 (strobes) 7125-1653:0224 SpectrAlert Advance Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 1'h-inch back box, 4-inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitTl Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full - wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field -selectable candela settings including 135, 150, 177, and 185. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads "low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync•CircuitM MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts (includes fire alarm panels with built in sync). When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three pattern, non -temporal (continuous) pattern and coded supply within the frequency range of 520Hz t 10% square wave tone. The low frequency sounder shall operate on a coded or non -coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non -coded power supply. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Frequency Range 520 Hz t 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142 mm L x 119 mm W x 33 mm D) Low Frequency Sounder/Stroh with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions (SBBR, SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR, SBBW) (145 mm L x 120 mm W x 76 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Low Frequency Current •. 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal. .. 0: Coded. UL Max. Current Draw (mA RMS), 2-Wire Low Frequency Sounder Strobe, High Candela Range (135-185 cd)16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 277 292 325 344 Temporal 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data Frequency Sounder and Low Frequency StrobeLow Sounder .: 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC Alert Advance Dimensions 4.7 in. 6.4 in. Wall -mount low frequency sounder strobes SpectrAlert Advance Ordering Information Wall -mount low frequency sounder Model.. Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe, High cd, Red P2WH-LF 2-Wire Low Frequency Sounder Strobe, High cd, White Low Frequency Sounders HR-LF Low Frequency Sounder, Red HW-LF Low Frequency Sounder, White Accessories SBBR Surface Mount Back Box, Wall, Red SBBW Surface Mount Back Box, Wall, White TR-HS Trim Ring, Wall, Red Notes: "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 02014 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensor.com Z... SENSOR for current product information, including the latest—sron of this data sheet. www.systemsensor.com AVDS16403. 5/14 SYSTEM SENSOR" Mini -Horns The SpectrAlerto Advance series of mini -horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non -temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA40O series Mini-AlertTM sounders • Listing for ceiling or wall mounting Agency Listings U` LISTED FM APPROVED U C _O� Vt 54011 3028007 CS1099 7135-1653.196 SPECTRAilert _. 9 o m.. e n s o r The MHR and MHW mini -horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini -horns offer high and low volume settings, and temporal or non -temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini -horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. SpectrAleW Advance Mini -Horn Specifications Mini -horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini -horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems. Mini -horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. When used with the Sync•Circuit'" Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Dimensions 4.61- x 2.9W x .451D Weight 2.67 oz. Operating Temperature Range 32°F to 120T (0°C to 49°C) Mounting Surface: deep single -gang back box (23/ ""deep) Flush: Standard 4-x 4-back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Ellectrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 16-33 VDC VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High temporal 72 71 75 74 80 79 4 Non- Low temporal Sounderr 70 69 73 72 78 77 Switch Position Sound Pattern 8-17.5 Volts Volume DC FWR 16-33 Volts DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non -temporal High 22 17 29 25 4 Non -temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini -Horn, Red MHW Mini -Horn, White 1 ,SYSTEM ©2o12 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit syslemsensoccom SENSOff Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,Ding the latest version of this data sheet. AV�S01So15oo • 3112 Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert@ Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field -selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert devices • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Aaencv Listinas SIGNALING! @ F M MEA i LISTED APPROVED PP a roved 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, 54011 (chimes, horn strobes, horns) 3023572 MEA452-05-E chime strobes) S5512 (strobes) 7135-1653:189 (horns, chimes) WA f r o m S s t' e m S -,. n s o -r, The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full - wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7-L x 4.8-W x 0.35-D (145 mm L x 122 mm W x 9 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non -temporal High 57 56 69 75 Non -temporal Medium 42 50 60 69 Non -temporal Low 41 44 50 50 Coded High 57 55 69 75 High 135 Candela 150 Range 177 185 NA NA NA NA NA NA NA NA 228 207 246 220 281 251 286 258 Coded Coded Medium Low 44 40 51 56 46 52 69 50 U-L Max, Current Draw (mA DC Input RMS), 2-Wire Horn 8-17.5 Volts 15 15f75 Strobe, Standard 16-33 Volts 15 Candela Range 15175 (15-115 30 cd) 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 k Hmt)), z-vvire morn birooe, coign ;,anoeia range t is�-iu� cal 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-1Z5 16-33 Volts Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non -Temporal High 82 82 88 88 93 92 100 100 5 Non -Temporal Medium 78 78 85 85 90 90 98 98 6 Non -Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions 31 Wail-mount horn strobes SpectrAlert Advance Ordering Information 'T••- !- inociet sescription Wail Horn Strobes Wall Strobes (cont.) P2R 2-Wire Horn Strobe, Standard cd, Red SRH Strobe, High cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain SRH-P Strobe, High cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" SRH-SP Strobe, High cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red SW Strobe, Standard cd, White P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain SW-P Strobe, Standard cd, White, Plain P2W 2-Wire Horn Strobe, Standard cd, White SWH Strobe, High cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain SWH-P Strobe, High cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White Horns P2WH-P 2-Wire Horn Strobe, High cd, White, Plain FIR Horn, Red P4R 4-Wire Horn Strobe, Standard cd, Red HW Horn, White P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain Accessories P4RH 4-Wire Horn Strobe, High cd, Red TR-HS Trim Ring, Wall, Red P4W 4-Wire Horn Strobe, Standard cd, White SBBR Indoor Surface Mount Back Box, Red Wall Strobes SBBW Indoor Surface Mount Back Box, White SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30. 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM3825 Ohio Avenue • St. Charles, IL 60174 02014 System Sensor. Phone: 800-SENSOR2 •Fax: 630-377-6495 Product specifications subject to change wihout notice. Visit systemsensoccom `.r�wj sK•� s current product information, including the latest version of this data sheet. SrEa www.s www.systemsensor.com .50 � stemsensor .com AVDS10201.1/14 SYSTEM �4 SENSOR'" Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Aaencv Listinas SIGNALING FM MEA 7300-1653 187 (outdoor strobes) TED approved 7125-1653..188 (horn strobes, S4011 (chimes, horn strobes, horns) AVFNWEU pp chime strobes) S3593 (outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653169 (horns, chimes) ...! JWV 4. 117 wom= SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40OF to 151 `F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an O-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the SynceCircuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SynceCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40°F to 151 °F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wail -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data 1 i. ..• 1 'T:IL Max.Morn Current I'r 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts " Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 Candela 150 Range 177 185 NA NA NA NA NA NA NA NA 228 246 281 286 207 220 251 258 Coded Coded Medium Low 44 40 51 56 46 52 69 50 UL Max. Current Draw (mA DC Input RMS), 2-Wire Horn 8-17.5 Volts 15 15(15 Strobe, Standard 16-33 Volts 15 Candela Range 15/75 (15-115 30 cd) 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe • Hom Tones and Sound Output Data Horn and Horn Strobe • .: 8-175 16-33 Switch Sound Volts Volts Position Pattern dB DC FWR DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR Listed Candela Candela rating at -40'F 15 Do not use below 321F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 1 2 3 Temporal Temporal Temporal High Medium Low 78 74 71 78 74 73 84 80 76 84 80 76 88 86 83 88 86 80 99 96 94 98 96 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams Wail -Mount Horn Strobes arproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wail Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15175, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 02012 System Sensor. SYSTEM ✓TEM 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoccom SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information,OS2the latest version of this data sheet. nvos01otz01ot • anz SYSTEM SENSOR' Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field -selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert devices • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Aaencv Listinas SIGNALING @L <F M> MEA .o LISTED S4011 (chimes, horn strobes, APPROVED horns) 3023572 approved MEA452-05-E 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, chime strobes) S5512 (strobes) 7135-1653:189 (horns, chimes) L07 mw.*"�w W.'.. m S e" s o`i The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 1 Y2-inch back box, 4-inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync -Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SynceCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full - wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor SynceCircuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120OF (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D (142 mm L x 119 mm W x 33 mm D) Wail -Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7"L x 4.8"W x 0.35"D (145 mm L x 122 mm W x 9 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8-175 Volts DC FWR 16-33 Volts DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non -temporal High 57 56 69 75 Non -temporal Medium 42 50 60 69 Non -temporal Low 41 44 50 50 Coded High 57 55 69 75 High 135 Candela 150 Range 177 185 NA NA NA NA NA NA NA NA 228 207 246 220 281 251 286 258 Coded Coded Medium Low 44 40 51 56 46 52 69 50 UL Max. Current rStrobe, DC Input 8-175 V0lts 15 15/75 Standard 16-33 Volts 15 Candela Range 15f75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 1 MPADI, L-YVire nut II MUUU, n ulI %,dffuer2t r14iKge %IJ3-IOZ) UUj 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-175 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non -Temporal High 82 82 88 88 93 92 100 100 5 Non -Temporal Medium 78 78 85 85 90 90 98 98 6 Non -Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions 3" Wail -mount horn strobes SpectrAlert Advance Ordering Information Wail Horn Strobes P2R 2-Wire Horn Strobe, Standard cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain P2W 2-Wire Horn Strobe, Standard cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White P2WH-P 2-Wire Horn Strobe, High cd, White, Plain P413 4-Wire Horn Strobe, Standard cd, Red P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" Wall Strobes (cont.) SRH Strobe, High cd, Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, "FUEGO" SW Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White, Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15l15, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM3825 Ohio Avenue • St. Charles, IL 60174 02014 System Sensor. ✓SENSOR l J _ Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensor.com SEA SOR y far current product information, S102 1 the fetes[ version of iFns data sheet. \J�yy /y www.systemsensor.com AVDS70201 • 1/14 Secondary•Requirements NWer SUOply Protected Premises: SUMMERSET APTS. P.S. #1 Date: 5/24/2016 Address: City: State: Zip: Prepared By: Phone: Address: Email: City: State: Zip: Secondary Load Requirements F 4.00 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.115 A x Required Standby Time 24 hours 2.76 Secondary Alarm Load 6.792 A x Required Alarm Time hours 0.084 hours 0.57 Total Secondary Load 3.33 Derating factor x 1.2 Secondary Load Requirements 4.00 AH Battery Selection Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt i Two • Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 10% Page 1 of 2 ■Spare Battery Capacity ■ Secondary Standby Load E Secondary Alarm Load Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). ISpare Battery Capacity 1 3.00[Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 1 3.31 1 Secondary Standby Load AH ` Derating Factor ISecondary Alarm Load 1 0.68 ISecondary Alarm Load AH " Derating Factor Page 2 of 2 Honeywell System Current Draw - HPFF8 Standb 0.115 A �. Alarm 6.792A 1. System Modules HPFF8 Main Circuit Board 1 x 0.07500 0.07500 1 x 0.20600 0.20600 2. NAC #1 P2W75 or P2R75 3 x 0,00000 0,00000 3 x 0.17600 0.52800 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 6 x 0.00000 0.00000 6 x 0. 13800 0.82800 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0,31600 P2WH-LF or P2RH-LF 3 x 0.00000 0.00000 3 x 0.29600 0.88800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAG #1 Totals (Max 3 Amps) 0.00000 2.61100 3. NAC #2 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0,00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 4 x 0,00000 0.00000 4 x 0.15800 0.63200 P2WH-LF or P2RH-LF 5 x 0.00000 0.00000 5 x 0.29600 1.48000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC 42 Totals (Max 3 Amps') 0.00000 2.46400 4. NAC #3 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 P2WK75 or P2RW75 0 x 0,00000 0 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 4 x 0.00000 0.00000 4 x 0.13800 0.55200 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 2 x 0.00000 0.00000 2 x 0.29600 0.59200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC 43 Totals (Max Amps)_ 0.00000 1.51100 5. NAC #4 FMM998 2 x 0.02000 0.04000 2 x 0.00000 0.00000 P2W75 or P2R75 0 x 0,00000 0 x 0.17600 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0,29600 0 x 0.00000 0 x 0.00000 NAG #4 Totals (Max 3 Amps): 0.04000 0.00000 6. Auxiliary Power Auxiliary Device 0 x 0,00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals (Max 1 Amps) 0.00000 0.00000 7. Compatible Devices not llsted Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0,00000 Total Non -Alarm Load: 0.115 Total Alarm Load: 6.792 j Protected Premises: SUMMERSET APTS. P.S. #2 Address: City: Prepared By: Address: City: State: State: Date: 5/24/2016 Zip: Phone: Email: Zip: Secondary Load Requirements 2.96 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.075 A x Required Standby Time 24 hours 1.80 Secondary Alarm Load 7.957 A x Re uired Alarm Time hours 0.084 hours 0.67 Total Secondary Load 2.47 Derating factor x 1.2 Secondary Load Requirements 2.96 Battery Selection 0 Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt • Two i Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 11% Page 1 of 2 ■Spare Battery Capacity ■ Secondary Standby Load ■Secondary Alarm Load AH Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). ISpare Battery Capacity 1 4.04 1 Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 1 2.16 ISecondary Standby Load AH * Derating Factor Seconda Alarm Load 1 0.80 1 Secondary Alarm Load AH * Derating Factor Page 2 of 2 �> _ lHoneywea Standb 0.075 A Alarm 7.957 A Secondary Non -Alarm Current Device Qty Draw Non- arm 1. System Modules HPFF8 Main Circuit Board 1 x 0.07500 0.07500 1 x 0.20600 0.20600 2. NAC #1 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 2 x 0.00000 0.00000 2 x 0.13800 0.27600 SW75 or SR75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 P2WH-LF or P2RH-LF 4 x 0.00000 0.00000 4 x 0.29600 1.18400 0 x 0.00000 0 x a00000 0 x 0.00000 0 x 0.00000 NAC #1 Totals (Max 3 A o%O O00000 2.44400 3. NAC #2 P2W75 or P2R75 2 x 0.00000 0,00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0,13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0.47400 P2WH-LF or P2RH-LF 4 x 0.00000 0.00000 4 x 0.29600 1.18400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC 42 Totals (Max 3 Amps) 0.00000 2.01000 4. NAC #3 P2W75orP2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 6 x 0.00000 0.00000 6 x 0.13800 0,82800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0.29600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals (Max 3 Amps) 0.00000 1.23100 5. NAC #4 FMM998 0 x 0.02000 0 x 0.00000 P2W75 or P2R75 4 x 0.00000 0.00000 4 x 0.17600 0.70400 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0.47400 P2WH-LF or P2RH-LF 3 x 0.00000 0.00000 3 x 0.29600 0,88800 0 x 0.00000 0 x 0.00000 NAC #4 Totals (Max 3 Amps): 0.00000 2.06600 6. Auxiliary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0,00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals tMax 2 Amps;. 0,00000 0.00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x 0,00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 7.957 Honeywell rM Requirements ,. a Protected Premises: SUMMERSET APTS. P.S. #3 Date: 5/24/2016 Address: City: State: Zip: Prepared By: Phone: Address: Email: City: State: Zip: Secondary Load Requirements 2.95 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.075 A x Re uired Standb Time 24 hours 1.80 Secondary Alarm Load 7.801 A x Required Alarm Time hours 0.084 hours 0.66 Total Secondary Load 2.46 Derating factor x 1.2 Secondary Load Requirements 2.95 Battery Selection Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt i Two • Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections Secondary Alarm Load 11% Page 1 of 2 Spare Battery Capacity Secondary Standby Load RSecondary Alarm Load AH Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). [Spare Battery Capacity 4.05 Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 2.16 Secondary Standby Load AH * Derating Factor ISecondary Alarm Load 1 0.79 Secondary Alarm Load AH * Derating Factor Page 2 of 2 Honeywell System Current Draw - I P Standby 0.075 A Alarm 7.801 A "�` T, Secondary Non -Alarm Current SecondmAlarm Curr2nt Device Qty .: 1. System Modules HPFFB Main Circuit Board 1 x 0.07500 1 0.07500 1 x 0.20600 0.20600 2. NAC #1 P2W75 or P2R75 4 x 0.00000 0.00000 4 x 0,17600 0,70400 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 P2WH-LF or P2RH-LF 4 x 0.00000 0.00000 4 x 0.29600 1.18400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #1 Totals (Max 3 Amps) 0.00000 2.52000 3. NAC #2 P2W75 or P2R75 3 x 0.00000 0.00000 3 x 0.17600 0.52800 P2WK75 or P21RW75 0 x 0.00000 0 x 0,17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 6 x 0.00000 0.00000 6 x 0.13800 0.82800 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 3 x 0.00000 0.00000 3 x 0,29600 0.88800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 1 x 0.00000 NAC 42 Tota3s (Max 3 Amps) 0.00000 2.61100 4. NAC #3 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 P2WH-LF or P2RH-LF 5 x 0.00000 0.00000 5 x 0.29600 1.48000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC; i#3 Totals (Max 3 Amps) 0.00000 2.46400 5. NAC #4 FMM998 0 x 0.02000 0 x 0.00000 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0.29600 0 x 0.00000 0 x 0.00000 NAC rr4 Totals (Max 3 Amps) 0.00000 0.00000 6. Auxiliary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals (Max 2 Amps), 0.00000 0.00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 7.801 Honeywell Requirements Protected Premises: SUMMERSET APTS. P.S. #4 Address: City: Prepared By: Address: City: State: State: Date: 5/24/2016 Zip: Phone: Email: Zip: Secondary Load Requirements 2.73 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.075 A x Required Standby Time 24 hours 1.80 Secondary Alarm Load 5.609 A x Required Alarm Time hours 0.084 hours 0.47 Total Secondary Load 2.27 Derating factor x 1.2 Secondary Load Requirements 2.73 Battery Selection Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt # Two • Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 8% Page 1 of 2 ■ Spare Battery Capacity • Secondary Standby Load Secondary Alarm Load AH Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). ISPare Battery Ca acit 4.27 Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 1 2.16 Secondary Standby Load AH * Derating Factor ISecondary Alarm Load 1 0.57 1 Secondary Alarm Load AH * Derating Factor Page 2 of 2 lHoneywell System Current nt Draw I.e.PFF Total. Iwa-indby 10.075A fn Alarm 5.609 A Secondary Non -Alarm Current Secondary Alarm Current Device QtY .. Qty Draw Alarm 1. stem Modules HPFF8 Main Circuit Board 1 x 0.07500 0.07500 1 x 0,20600 0.20600 2. NAC #1 P2W75 or P21R75 1 x 0.00000 0.00000 1 x 0.17600 0.17600 P2WK75 or P21RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 4 x 0.00000 0.00000 4 x 0.13800 0.55200 SW75 or SR75 0 x 0.00000 0 x 0,15800 P2WH-LF or P2RH-LF 2 x 0.00000 0.00000 2 x 0.29600 0.59200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC it! Totals (Max 3 Amps;- 0.00000 1.37100 3. NAC #2 P2W75 or P21R75 0 x 0.00000 0 x 0.17600 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 2 x 0.00000 0.00000 2 x 0.01700 0.03400 HW-LF 4 x 0.00000 0.00000 4 x 0.13800 0.55200 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0,29600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC 42 Totals (Max 3 Amps) 0.00000 0.58600 4. NAC #3 P2W75 or P2R75 3 x 0.00000 0.00000 3 x 0.17600 0.52800 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0,01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0.47400 P2WH-LF or P2RH-LF 3 x 0.00000 0.00000 3 x 0.29600 0.88800 0 x 0.00000 o x 0.00000 0 x 0.00000 0 x 0,00000 NAC 93 Totals (MaxAmps)_ 0.00000 1.89000 -3 5. NAC #4 FMM998 0 x 0.02000 0 x 0.00000 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0 35200 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0,00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 3 x 0.00000 0.00000 3 x 0.29600 0.88800 0 x 0.00000 0 x 0.00000 NAC 04 Totals (Max 3 Amps) 0.00000 1.55600 6. Auxiliary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals (Max 2 Amhsj- 0.00000 0.00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 1 0 1 x 10.00000 Other compatible devices 0 x 0.00000 1 0 1 x 1 0.00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 5.609 =�Well Secondary Power Requirements Protected Premises: SUMMERSET APTS. P.S. #5 Date: 5/24/2016 Address: City: State: Zip: Prepared By: Phone: Address: Email: City: State: Zip: Secondary Load Requirements 3.92 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.115 A x Required Standby Time 24 hours 2.76 Secondary Alarm Load 6.037 A x Required Alarm Time hours 0.084 hours 0.51 Total Secondary Load 3.27 Derating factor x 1.2 Secondary Load Requirements 3.92 Battery Selection �7 Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt # Two • Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 9% Page 1 of 2 ■ Spare Battery Capacity ■ Secondary Standby Load Secondary Alarm Load AH Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). ISpare Battery Capacity 1 3.08 Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 1 3.31 Secondary Standby Load AH * Derefing Factor ISecondary Alarm Load 1 0.61 ISecondary Alarm Load AH * Derafing Factor Page 2 of 2 Honeywell System Current Draw - HPFF8 Standb 0.115 A Alarm 6 037 A Secondary Non -Alarm Current Secondary Alarm Current .• • - Oty Draw Alarm 1. System Modules HPFF8 Main Circuit Board 1 1 x 1 0.07500 0.07500 1 x 0.20600 0.20600 2. NAC #1 P2W75 or P2R75 1 x 0.00000 0.00000 1 x 0,17600 0.17600 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 3 x 0.00000 0.00000 3 x 0.29600 0.88800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC tti Totals (Max 3 Amps) 0.00000 1.38000 3. NAC #2 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0.47400 P2WH-LF or P2RH-LF 3 x 0.00000 0.00000 3 x 0.29600 0.88800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC 442 Totals 'Max 3 Amps) 0.00000 1.71400 4. NAC #3 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 1 x 0,00000 0.00000 1 x 0.01700 0.01700 HW-LF 2 x 0.00000 0.00000 2 x 0.13800 0.27600 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 6 x 0,00000 0.00000 6 x 0.29600 1.77600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC 43 Totals (Max 3 Amps) 0.00000 2.73700 5. NAC #4 FMM998 2 x 0.02000 0.04000 2 x 0.00000 0.00000 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0.29600 0 x 0.00000 0 x 0.00000 NAC 44 Totals (Max 3 Amps) 0.04000 0,00000 6. Auxiliary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals (Max 2 Amps): 0.00000 0.00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 1 x 0.00000 Total Non -Alarm Load: 0.115 Total Alarm Load: 6.037 I Honeywell Secondary over Requirements Protected Premises: SUMMERSET APTS. P.S. #6 Date: 5/24/2016 Address: City: State: Zip: Prepared By: Phone: Address: Email: City: State: Zip: Secondary Load Requirements 2.95 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.075 A x Required Standby Time 24 hours 1.80 Secondary Alarm Load 7.801 A x Required Alarm Time hours 0.084 hours 0.66 Total Secondary Load 2.46 Derating factor x 1.2 Secondary Load Requirements 2.95 Battery Selection 0 Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt • Two • Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 11% Page 1 of 2 ■ Spare Battery Capacity ■ Secondary Standby Load Secondary Alarm Load Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). JSpare Battery Capacity 4.05[Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 2.16 1 Secondary Standby Load AH * Derating Factor ISecondaryAlarrn Load 1 0.79 1 Secondary Alarm Load AH * Derating Factor Page 2 of 2 HoneywellSystem,: Current Draw ® H FF Standb 0.075A Alarm 7.801 A ry, iu` rPh R-nn, Seconde Non -Alarm Current Alarm Current 1, System Modules HPFF8 Main Circuit Board 1 x 1 0.07500 0.07500 1 x 0.20600 0,20600 2. NAC #1 P2W75 or P2R75 4 x 0.00000 0.00000 4 x 0,17600 0.70400 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0,01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 P2WH-LF or P2RH-LF 4 x 0.00000 0.00000 4 x 0.29600 1.18400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAG #1 Totals (Max 3 Anps) 0.00000 2.52000 3. NAC #2 P2W75 or P2R75 3 x 0.00000 0.00000 3 x 0.17600 0.52800 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 6 x 0.00000 0.00000 6 x 0.13800 0.82800 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 3 x 0.00000 0.00000 3 x 0.29600 0.88800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC 42 Totals iPAeX 3 Amps) 0.00000 2.61100 4. NAC #3 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 P2WH-LF or P2RH-LF 5 x 0.00000 0.00000 5 x 0.29600 1.48000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals (Max mps)_ a00000 2.46400 5. NAC #4 FMM998 0 x 0.02000 0 x 0.00000 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 1 0 x 0.00000 0 x 0.29600 0 1 x 1 0.00000 0 x 0.00000 NAC #4 Totals (Max 3 Amps). 0.00000 0.00000 6. AuxIllary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 1 0.00000 0 x 0.00000 TB4 Totals (Max 2 Am4,,): 0.00000 0.00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x a00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x a00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 7.801 HoneywellSecondary Power Requirements HPFFS Power Supply Protected Premises: SUMMERSET APTS. P.S. #7 Date: 5/24/2016 Address: City: State: Zip: Prepared By: Phone: Address: Email: City: State: Zip: Secondary Load Requirements 2.93 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.075 A x Required Standby Time 24 hours 1.80 Secondary Alarm Load 7.596 A x Required Alarm Time hours 0.084 hours 0.64 Total Secondary Load 2.44 Derating factor x 1.2 Secondary Load Requirements 2.93 Battery Selection �7 Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt * Two i Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 11% Page 1 of 2 ■ Spare Battery Capacity ■ Secondary Standby Load ■Secondary Alarm Load AH Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). ISPare Battery Capacity 4.07 1 Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 2.16 1 Secondary Standby Load AH * Derating Factor Seconds Alarm Load 1 0.77 ISecondary Alarm Load AH * Derating Factor Page 2 of 2 Honeywell System Current Craw - H FF .... �� ..' Standb 0.075A t ��hl. ",�4. n��a�, �� W�1146 Alarm 7.596 A DeviceQty Draw • 1. System Modules HPFF8 Main Circuit Board 1 x 0.07500 0.07500 1 x 0.20600 0.20600 2. NAC #1 P2W75 or P2R75 1 x 0.00000 0.00000 1 x 0.17600 0.17600 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 6 x 0.00000 0.00000 6 x 0.13800 0.82800 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 2 x 0.00000 0.00000 2 x 0.29600 0.59200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC ttt 7blals (Max 3 Amps; 0.00000 1.96300 3. NAC #2 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 6 x 0.00000 0.00000 6 x 0,13800 0.82800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0.29600 0 x 0.00000 0 x 0.00000 0 1 x 1 0.00000 0 x 0.00000 NAG 42 Totals (Max 3 Amps) 0.00000 1.23100 4. NAC #3 P2W75 or P2R75 3 x 0.00000 0.00000 3 1 x 0.17600 0.52800 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0,47400 P2WH-LF or P2RH-LF 4 x 0.00000 0.00000 4 x 0.29600 1.18400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0,00000 NAC 43 Totals (Max 3 Amps)- 0.00000 2.18600 5. NAC #4 FMM998 0 x 0.02000 0 x 0.00000 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0,00000 0 x 0,01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0.47400 P2WH-LF or P2RH-LF 4 x 1 0.00000 0.00000 4 x 0.29600 1.18400 0 x 0.00000 0 x 0.00000 NAG 44 Totals (M<ax 3 Amps;: 0.00000 2.01000 6. Auxiliary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals fMax 2 An)ps).1 0.00000 0.00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Total Non -Harm Load: 0.075 Total Alarm Load: 7.596 Honeywell: ower Requirements i Protected Premises: SUMMERSET APTS. P.S. #8 Date: 5/24/2016 Address: City: State: Zip: Prepared By: Phone: Address: Email: City: State: Zip: Secondary Load Requirements 3. 55 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.115 A x Required Standby Time 24 hours 2.76 Secondary Alarm Load 5.307 A x Required Alarm Time hours 0.084 hours 0.45 Total Secondary Load 3.21 Derating factor x 1.2 Secondary Load Requirements 3.85 Battery Selection �7 Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt 0 Two • Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 8% Page 1 of 2 •Spare Battery Capacity ■Secondary Standby Load Secondary Alarm Load AH Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). ISPare Battery Capacity 3.15[Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 1 3.31 1 Secondary Standby Load AH * Derating Factor ISecondary Alarm Load 1 0.53 ISecondary Alarm Load AH * Derafing Factor Page 2 of 2 Honeywell System Current Craw - HPFF8 .: stand 15 AAlarm F53 F 07 A Secondary Non -Alarm Current SecondmAlarm CurLen Device . . 1. System Modules HPFF8 Main Circuit Board 1 x 0.07500 0.07500 1 x 0.20600 1 0.20600 2. NAC #1 P2W75 or P2R75 1 x 0.00000 0.00000 1 x 0.17600 0.17600 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0.47400 P2WH-LF or P2RH-LF 3 x 0.00000 0.00000 3 x 0.29600 0.88800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAG ttl Totals (Max 3 Amps') 0.00000 1.53800 3. NAC #2 P2W75 or P2R75 2 x 1 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0.47400 P2WH-LF or P2RH-LF 4 x 0.00000 0.00000 4 x 0.29600 1.18400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x a00000 NAC 42 Totals (Max 3 Amps` 0.00000 2.01000 4. NAC #3 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 1 x 0.00000 0.00000 1 x 0.01700 0.01700 HW-LF 2 x 0.00000 a00000 2 x 0,13800 0.27600 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0,31600 P2WH-LF or P2RH-LF 2 x 0.00000 0.00000 2 x 0.29600 0.59200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals (Max 3 Amos) 0.00000 1,55300 5. NAC #4 FMM998 2 x 0.02000 0.04000 2 x 0.00000 0.00000 P2W75 or P2R75 0 x 0,00000 0 x 0.17600 P2W75 or P2R75 0 x 0.00000 0 x 0,17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0.29600 0 x 0.00000 0 x 0.00000 NAC 94 Totals (Max 3 Amps)- 0.04000 0.00000 6. Auxiliary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 AuxiliaryDevice 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals (Max 2 Amps). 0.00000 0.00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Total Non -Alarm Load: 0.115 Total Alarm Load: 5.307 Honeywell ,,ower !I equiremetrIts Protected Premises: SUMMERSET APTS. P.S.#9 Date: 5/24/2016 Address: City: State: Zip: Prepared By: Phone: Address: Email: City: State: Zip: Secondary Load Requirements 2.95 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.075 A x Required Standby Time 24 hours 1.80 Secondary Alarm Load 7.801 A x Required Alarm Time hours 0.084 hours 0.66 Total Secondary Load 2.46 Derating factor x 1.2 Secondary Load Requirements 2.95 Battery Selection 0 Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt • Two ! Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 11% Page 1 of 2 • ■ Spare Battery Capacity Secondary Standby Load Secondary Alarm Load 02 Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). ISPare Battery Capacity 4.05 1 Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 2.16 ISecondary Standby Load AH * Derating Factor ISecondary Alarm Load 1 0.79 1 Secondary Alarm Load AH * Derating Factor Page 2 of 2 :..,r . Honeywell System Correct draw - HP Standb 0.075 - Alarm 7.801 A " HPFF8 Main Circuit Board 1 1 x 1 0.07500 1 0.07500 1 1 1 x 1 0.20600 1 0.20600 2. NAC #1 P2W75 or P2R75 4 x 0.00000 0.00000 4 x 0.17600 0.70400 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 P2WH-LF or P2RH-LF 4 x 0.00000 0.00000 4 x 0.29600 1.18400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC; III Totals (Max 3 Amps) 0.00000 252000 3. NAC #2 P2W75 or P2R75 3 x 0.00000 0.00000 3 x 0.17600 0,52800 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0,01700 0,05100 HW-LF 6 x 0.00000 0.00000 6 x 0.13800 0.82800 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 3 x 0.00000 0,00000 3 x 0.29600 0.88800 o x 0.00000 0 x o.00000 o 1 x 1 0.00000 0 x 0.00000 NAG 42 Tolals (Max 3 Amps), 0.00000 2.61100 4. NAC #3 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 P2WH-LF or P2RH-LF 5 x 0.00000 0.00000 5 x 0.29600 1.48000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals (Max 3 Amos) 0.00000 2.46400 5. NAC #4 FMM998 0 x 0.02000 0 x 0.00000 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 1 0 x 0.29600 0 x 0.00000 0 x 0.00000 NAC IN Totals (Max 3 Amps) 0.00000 0.00000 6. Auxiliary Power Auxiliary Device 0 x 1 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0,00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals (Max 2 A;nps) j 0.00000 0.00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x 0,00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Total NonAlarm Load: 0.075 Total Alarm Load: 7.801 Honeywell Protected Premises: SUMMERSET APTS. P.S.#10 Address: City: Prepared By: Address: City: State: State: Date: 5/24/2016 Zip: Phone: Email: Zip: Secondary Load Requirements 2. 0 1 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.075 A x Required Standby Time 24 hours 1.80 Secondary Alarm Load 7.320 A x Required Alarm Time hours 0.084 hours 0.61 Total Secondary Load 2.41 Derating factor x 1.2 Secondary Load Requirements 2.90 Battery Selection �7 Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt • Two • Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 10% Page 1 of 2 in Spare Battery Capacity ■Secondary Standby Load Secondary Alarm Load AH Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). ISPare Battery Capacity 4.10 1 Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 2.16 1 Secondary Standby Load AH " Derating Factor ISecondary Alarm Load 1 0.74 ISecondary Alarm Load AH ' Deratinp Factor Page 2 of 2 Honeywell System Current Draw - HPFF8 ,FIFIr_ 'Standby 10.075A� ='Alarm 7.320 A HPFFB Main Circuit Board 1 1 x 1 0.07500 1 0.07500 1 1 1 x 0.20600 1 0.20600 2. NAC #1 P2W75 or P2R75 1 x 0.00000 0.00000 1 x 0.17600 0.17600 P2WK75 or P2RW75 0 x 1 0.00000 0 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 4 x 0.00000 0.00000 4 x 0.13800 0.55200 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 2 x 0.00000 0.00000 2 x 0.29600 0.59200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC N1 Totals (Max 3 Ai7tps} 0.00000 1.68700 3. NAC #2 P2W75 or P2R75 2 x 0.00000 0.00000 2 1 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 1 x 0.17600 MHW or MHR 3 x 0.00000 0.00000 3 x 0.01700 0.05100 HW-LF 6 x 0,00000 0.00000 6 x 0.13800 0.82800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0.29600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC 42 Totals (Max 3 Amps) 0.00000 1.23100 4. NAC #3 P2W75 or P2R75 3 x 1 0.00000 0.00000 3 x 0.17600 0.52800 P2WK75 or P2RW75 0 x 1 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0.47400 P2WH-LF or P2RH-LF 4 x 0.00000 0.00000 4 x 0.29600 1.18400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x o.00000 NAC #3 Totals (Max 3 Amps): 0.00000 2,18600 5. NAC #4 FMM998 0 x 0.02000 0 x 0.00000 P2W75 or P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 3 x 0.00000 0.00000 3 x 0.15800 0.47400 P2WH-LF or P2RH-LF 4 x 0.00000 0.00000 1 4 x 0.29600 1.18400 0 x 0.00000 0 x 0.00000 NAC rt4 Totals (Max 3 Amps), 0.00000 2.01000 6. Auxlllary Power Auxiliary Device 0 x 0,00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals (Max 2 Amps): 0.00000 0.00000 Other compatible devices 0 x 0.00000 0 x 1 0.00000 Other compatible devices 0 x 0.00000 0 x 1 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 7.320 Protected Premises: SUMMERSET APTS. P.S. #1' Address: City: Prepared By: Address: City: State: State: Secondary Load Requirements 3.74 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.115 A x Required Standby Time 24 hours 2.76 Secondary Alarm Load 4.220 A x Required Alarm Time hours 0.084 hours 0.35 Total Secondary Load 3.11 Derating factor x 1.2 Secondary Load Requirements 3.74 Battery Selection Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt i Two 0 Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 6% Page 1 of 2 ■Spare Battery Capacity ■Secondary Standby Load Secondary Alarm Load AH Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). ISpare Battery Capacity 13.26 1 Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 1 3.31 ISecondary Standby Load AH * Derating Factor ISecondary Alarm Load 1 0.43 ISecondary Alarm Load AH ' Derating Factor Page 2 of 2 Honeywell System Current Drava m HPFF8 iv t' Tarmarm b b0115A 14.220 A a..... ., c,o.an?i-r-�I�1.; :,tu mom,, �e ..,z' n'icr�.'...�, 2. NAC #1 P2W75 or P2R75 P2WK75 or P2RV MHW or MHR HW-LF SW75 or SR75 P2W75 or P2R75 P2WK75 or P2RV MHW or MHR HW-LF SW75 or SR75 P2WK75 or P2RW75 or P2RH-LF FMM998 P2W75 or P2R75 P2W75 or P2R75 MHW or MHR HW-LF SW75 or SR75 6. Auxiliary Power Auxiliary Device Auxiliary Device Auxiliary Device Auxiliary Device Auxiliary Device 7. Compatible Devices r Other compatible devices Other compatible devices Other compatible devices 0.07500 1 0.07500 0 1 x 1 0.00000 1 x 0.00000 0.00000 2 x 0.00000 0.00000 4 x 0.00000 0.00000 4 x 0.00000 0.00000 0 x 0.00000 0 x 0.00000 NA tt1 Totals (Max 3 iunus). 0.00000 o 1 x 1 0.00000 1 x 0.00000 0.00000 2 x 0.00000 0.00000 2 x 1 0.00000 0.00000 2 x 0.00000 0.00000 0 x 0.00000 0 x 0.00000 NAC 1 `L Totals Ilvlax 3 Amps) 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAB l3 Totals (Max 3 Amps) 0.00000 2 x 0.02000 0.04000 0 x 0.00000 0 x 0.00000 0 x 0,00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 Totals (Max 3 At nos), 0.04000 0 x 1 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 TB4 Totals (Max 2 Amps), 0.0000 0 x 0.00000 0 x 0:00000 0 x 0.00000 Total Non -Alarm Load: 0.115 2 x 1 0.17600 0.35200 0 x 0.17600 1 x 0.01700 0,01700 2 x 0.13800 0.27600 4 0.15800 0.63200 4 1.18400 o JX�0.29600 .000000 .00000 2.46100 2 x 0.17600 0.35200 0 x 0,17600 1 x 0.01700 0.01700 2 x 0.13800 0.27600 2 x 0.15800 0.31600 2 x 0,29600 0,59200 0 x 0.00000 0 x 0.00000 1.55300 0 x 0.17600 0 x 0.17600 0 x 0.01700 0 x 0.13800 0 x 0.15800 0 x 0.29600 0 x 0.00000 0.00000 I 0 x 1 0.17600 0 x 0.17600 0 x 0.01700 0 0.13800 0 0.15800 0 IX 0.296000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 Total Alarm Load: 4220 Honeywell Secondary Power Requirements Protected Premises: SUMMERSET APTS. P.S. #12 Date: 5/24/2016 Address: City: State: Zip: Prepared By: Phone: Address: Email: City: State: Zip: Secondary Load Requirements 2.34 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Load 0.075 A x Required Standby Time 24 hours 1.80 Secondary Alarm Load 1.759 A x Required Alarm Time hours 0.084 hours 0.15 Total Secondary Load 1.95 Derating factor x 1.2 Secondary Load Requirements 2.34 Battery Selection 0 Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery 12 volt ! Two i Four (two 12VDC sets in parallel) Battery Distribution Chart Shows amp -hour distribution of your selections Secondary Alarm Load 2% Page 1 of 2 ■Spare Battery Capacity ■ Secondary Standby Load Secondary Alarm Load AH Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-26AH). [Spare Battery Capacity 1 4.66 1 Battery Selection AH - Secondary Load Requirements AH ISecondary Standby Load 1 2.16 ISecondary Standby Load AH ' Derating Factor ISecondary Alarm Load 1 0.18 1 Secondary Alarm Load AH ' Derating Factor Page 2 of 2 Honeywell System Current Dr - HPFF8 Standb 0.075 A Alarm 1.759A HPFF8 Main Circuit Board 1 1 x 1 0.07500 1 0.07500 1 1 1 x 1 0.20500 1 0.20600 2. NAC #1 P2W75 or P2R75 2 x 1 0.00000 0.00000 2 x 0.17600 0.35200 P2WK75 or P2RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 1 x 0.00000 0.00000 1 x 0.01700 0.01700 HW-LF 2 x 0.00000 0.00000 2 x 0.13800 0.27600 SW75 or SR75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 P2WH-LF or P2RH-LF 2 x 0.00000 0.00000 2 x 0.29600 0.59200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 1 x 0.00000 NAC it i 'Totals {Max 3 Amps, 0.00000 1.55300 3. NAC #2 P2W75 or P21R75 0 x 0.00000 0 x 0.17600 P2WK75 or P2RW75 0 x 0,00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0.29600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC 42 Totals (Max 3 Amps) 0.00000 0.00000 4. NAC #3 P2W75 or P2R75 0 x 0.00000 0 x 0.17600 P2WK75 or P21RW75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 x 0.00000 0 x 0.29600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC t3 Totals (Max 3 Amps) 0.00000 0 00000 5. NAC #4 FMM998 0 x 0.02000 0 x 0.00000 P2W75 or P21R75 0 x 0.00000 0 x 0.17600 P2W75 or P21R75 0 x 0.00000 0 x 0.17600 MHW or MHR 0 x 0.00000 0 x 0.01700 HW-LF 0 x 0.00000 0 x 0.13800 SW75 or SR75 0 x 0.00000 0 x 0.15800 P2WH-LF or P2RH-LF 0 1 x 0.00000 0 x 0.29600 0 x 0.00000 0 x 0.00000 NAC rr4 Totals (Max 3 Amps}. 0.00000 0.00000 6. Auxiliary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 AuxiliaryDevice 0 x 0.00000 0 x 0.00000 AuxiliaryDevice 0 x 0.00000 0 x 0.00000 AuxiliaryDevice 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals tMax 2 Amps; 0.00000 0-00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 1.759 Fo�� � o��r projects, contact us. System includes Phone & Distribution Module `12Zone 25OV42RC ^58Zone 25OO-56RC °1GZone 25O0'1GRC ^7OZone 25UO-76RC ,2OZone 250O-28RC ^92Zone 25U0'82RC ^30Zone 250O-38gC Dimensions: ^25O&12RC/46RC:12"Wx15.12^Mx0.125^D ~25OU'28RC/-30R[X-5dRO/-76RC/'92RC: 20.3'lNx21.07~Hx5.125~D System includes Phone & Distribution Module ~16Zone 250U-16RCF ^TOZone 25OU-70RCF ^28Zone 250U-28RCF 92Zone 25OO-92RCF ^38Zone 25VO'36RCF Dimensions: 2500-12RCF/'16ROF: ^Front Frame: 14"Wx1811*Hx3"O ^Back Box: 12"VYx15.625"Hx3.0OI) 2500-20RCF -30RCF-56RCF/'76RKCF-92RCF: `Front Frame: 25°Wx2111lHx3I) Command Center: Surface and flush cabinet or desk mount 'Powder coated steel enclosure with twist lock closure ^Base and Sub -Master stations mDistribution Module: 12'18Zone (single pair) 28-5GZone (2pair) and 7O-82Zone (Jpair) ^Machine room phone (23OO-83ORC)(single pair) ^SmurtPhunou*oDistribution Module (single pair) `Can Ueconfigured with the main Base Station, multiple Sub -Master Stations (available indesk, surface orflush mount) and Machine Room Phones (23V0'83URC) `Base Station includes handset for communication 0oelevators `Works with our model 21OOseries 8mortPhoneo ^Base Station, Sub -Master Stations and Machine Room Phones are powered from the Distribution Module (except 8martPhoneo) ^Audible alert sounds when phone(y)place acall until Base Station urSub-Master Station joins conversation ^LED'eindicate which phune(m)have initiated ocall ^ Calls wait inqueue until previous call |sdisconnected and receive omessage stating that onemergency call io/nprogress. When the prior call clears, the next phone inqueue iaconnected. Rescue personnel ran communicate with individual phone(m)and outside party ~AD8.A8K4EA17.and B44code compliant 'yyear warranty System includes Phone & Distribution Module Model Number: Distribution Module ^ Surface Mount • Included with Base Ste ,12Zone 25OO- 2NC ~1GZone 25UQ-1SNO ^28Zone 25QO-28NC ^3GZone 258O-38NC ^58Zone 2500'58NC ^78Zone 25U0-7GNC ^A2Zone 25U0'92NC Module: 41 ~ Install onawall ortable top ^ Requires 12Uvuopower with battery back-up ' orRath power supply with battery back-up ^ Single dedicated phone line orauanIntercom System N55W24720 N.Corporate Circle ° Sussex, Wl 53089 amn-AS*-+uAm ° �A'5-nA6Z-um0m/+=vl " ui"°"�~r%,= Made in 12!15 Model Number: 240U05SP Model Number: 2400-805RP Model Number: 2400-805LP Size: 4-3/4" W x 7-1/4" H x 1-7/8" D Size: 4-3/4" W x 7-1/4" H x 1-7/8" D Size: 6" W x 9-1/2" H x 2-7/8" D Standard: Stainless Steel Standard: Red, Powder Coated Standard: Red, NEMA 4, Fiberglass Surface Mount Surface Mount Surface Mount Option: Mushroom Button Option: Mushroom Button Option: Mushroom Button Model Number: 2400-805LPC1 Model Number: 2400-805SSPC2 Size: 6" W x 9-1/2" H x 2-7/8" D Face Plate: 6-17/25" W x 10" H Standard: Red, NEMA 4, Fiberglass Back Box: 6-1/2" W x 9-718" H x 2-3/10" D Surface Mount Cover: 6-1/8" W x 9-8/9" H x 1-3/4" D Standard: Stainless Steel, Surface Mount Model Number: 2400-808NSP Size: 7-1/2" W x 9-1/2" H Back Box: 6" W x 8" H x 3" D Standard: Brushed Stainless Steel Flush Mount Option: Mushroom Button Features: Model Number: 2400-808SSPC2 Face Plate: 8" W x 11-3/8" H Back Box: 6-1/2" W x 9-7/8" H x 3" D Cover: 6-118" W x 9-8/9" H x 1-3/4" D Standard: Brushed Stainless Steel Flush Mount • Designed to be powered from the Distribution Module and requires a single pair from the Distribution Module • Programmable with up to two emergency phone numbers • Recordable location message (25 seconds) • On -site programming • Numeric programming keypad • Automatic dialer (32 digit programmable memory) • Automatic answer feature with audible ring • IBC, NI PA, and ADAAG Code Compliant • Braille label N56 W24720 N. Corporate Circle • Sussex, WI 53089 800451-1460 • 262-246-4828 (fax) • www.area-of-refuge.com NEE Made to the USA 3 Yea, Wa"m Model Numbers RP7700104 (12-36 zone) RP7700105 (56-92 zone) RP7700104 (10-128 zone IP) Dimensions RP7700104: 9.8" H x 3.9" W x 15.1 " D RP7700105: 17" H x 7.7" W x 21.42" D Weight RP7700104: 23.5 lbs. RP7700105: 112 lbs. Output Power Capacity RP7700104: 1 OOOVA / 60OW RP7700105: 1920VA / 1920W Note: Command Center with a single Elevator Phone draws 7.21 W Each additional Phone adds 4.46W • Power Supply with Battery Backup • 120vac • Sealed, lead acid, maintenance free battery • Underwriters Laboratory Recognized (UL 1778) • RoHS compliant • Visual and audible alarms • LCD Screen gives utility and battery back-up status • Battery back-up and surge protected outlets keep the Command Center running when the power goes out during an emergency NE—=— N56 W24720 N. Corporate Circle • Sussex, Wl 53089 Madem Me U1 800-451-1460 * 262-246-4828 (fax) * www.rathmicrotech.com 3 Year Waaan Photo Luminescent Wall Sign Model Number: 7041 Size: 8" x 8" AREA OF EFPG�. Braille Photo Luminescent Wall Sign Model Number: 7046 Size: 8" x 8" 120/277vac Lighted Wall Sign Model Numbers: 7050 (Single Sided) or 7050D (Double Sided) Size: 10.5" H x 14" W x 3" D 91 Raised Letter/Braille Entry Way Sign Model Numbers: 7043 - Black/White Size: 6" x 9" 7044 - Blue/White Size: 6" x 9" Directional Sign Model Numbers: 7047L (Left Arrow) 7047R (Right Arrow) Size: 15" x 5" Features: • Power: 120/277vac (4w, 350mA) • 90 Minutes of Battery Back-up • LED Lights • Constant Uniform Illumination • UL Listed to meet UL 924, NEC, OSHA, NFPA 8t Life Safety Code Illumination requirements • White Aluminum Housing With Acrylic Surface • Voltage Surge and Short Circuit Protection • Directional Arrows Available Upon Request PUSH FOR HELP COCAitO" FLOOR Persons able to use the exit rtarrway do so as soon as possibto, uniess they are assistt"s others. After s.tHst3'p the two-way omorgoncy eommunietNten system, waft I Pero for assistarrCe. i "Directions for Call Boxes" Wall Sign (With Braille) Model Number: 7049 Size: 6" x 8" Exterior Rescue Assistance Wall Sign Model Number: 7086 Size: 8" x 8" Skid Resistant Floor Decal Model Number: 7045 Size: 17" D N56 W24720 N. Corporate Circle a Sussex, WI 53089 800-451-1460 • 262-246.4828 (fax) • www.area-cif-refuge.com Made in the USA 3 Year Warm my