Loading...
HomeMy WebLinkAbout37849 Dusty Saddle Ln660 - FILLMORE Garage Left - Elevation I SHEET INDEX NUMBER: SHEET NAME: \ BER: SHEET NAME: CS COVER SHEET E-1.0 ELECTRICAL PLANS - FIRST FLOOR CS-3 SQUARE FOOTAGE CALCULATIONS A-3.2 MISC DETAILS F-1.0 FOUNDATION - SLAB PLAN A-3.4 MISC DETAILS A-1.0 FRST FLOOR PLAN A-3.10 =RONT/REAR ELEVATIONS I/ROOF PLAN A-3,11 5 D=-__vAT'O\S BUILDING SECTIONS GENERAL tiCTE5 THE STANDARD GENERA_ SPECIFICATIONS FOR AMERICAN HOMES 4 RENT t AMH MODIFIED tSUPPLEMENTEDY TH DEVELOPMENT 51-.AL_ GOVERN EXCEPT AS MOD ED B ESE PLANS. THESE PLANS HAVE BEEN DESIGNED TO MEET THE REQUIREMENTS OF. 2023 FLORIDA BUI DING CODE, RESIDENTIAL, 37H EDITION OCCUPANCY: SINGLE FAMILY RESIDENTIAL GE \� CONS RUCTION: , 4R46E SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA 5- \ I E65 HAN 1/2 INCH (I27 mm) GYPSUM BOARD API —LIED TO THE GARAGE SIDE-ARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL F Y THAN / INCH (159 i T"a= 'X GYPSUM LAB 'B_E ROOMS ABOV_ B NOT LESS AN 5 8 NC G BG OR EQLI VA- - ENT. WHERE THE SEPARATION 15 A FLOOR CEILIN ASSEMBLY T z„CTUR_ SUPPORTING THE SEPARATION SHALL ALSO BE PR0 ECTED BY NOT LESS '-AN I/2 INCH !12l mm) GYPSUM BOARD OR EQUIVALENT. EXTERIOR FINISHES: THICKNESS OF TEXTURED FINISH OVER FRAME APPLICATION SHALL BE PER THE CURRENT APPROVED BUILDING CODE AND ASTM C926. INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER THE CURRENT APPROVED BUILDING CODE AND ASTM C 1063_ EGRESS. I EACH EE�-FOO- ., _;NE ,-, \ ^^m _ CRESS CODES., IF THERE 5 NC<- C x R.OR - - �R_'- SS WINDOWS SHALL PROVID --AR OPENING OF NOT LFe.- 24 'N HEIGHT AND 5. SQ.= . IN AREA (50 SQFT_ AT GRACE 0= T-E CLEAR OPENING- S-4L- NOT BE MORE THAN 44" AEGVE T,-- =LOORJ 2. IN DWI NG UNITS WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN -.2 INCHES ABOVE THE FINISHEDGRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR. OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT O­ N'NG--S TH A- ALLOW PASSAGE OF A 4" SPHERE WHERE SUCH OPENINGS ARE _ '-. N 24 INCHES OF THE FINISHED FLOOR PER THE CURRENT APPROVE D BALD' NG- CODE. FLASHING: I. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES 'N ROOF SLOPE OR DIRECTION,: AND AROUND ROOF OPENINGS. 2. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED' SHINGLE FASHION IN SUCH A MANNER 45 TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION -RESISTANT FLASHING SHALL BE INSTALLED AT ALL REQUIRED LOCATIONS PER THE CURRENT APPROVED BUILDING CODE, WINDOW NSIALLATION. 1. WINDOWS SHALL BE INSTALLED AND F LA HED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW FLOOD ZONE REQUIREMENT5: I. PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION BATH AREAS: L INSTALL 2x4 BLOCKING AT TOILET PAPER AND TOWEL BAR LOCATIONS, SEE DETAILS. KITCHENS: I. INSTALL 2X6 BLOCKING AT 89" AFF, ON CENTER FOR UPPER CABINET INSTALLATION_ TUB AND SHOWER AREAS: I. CEMENT, FIBER -CEMENT, OR GLASS MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH ASTM 0288, CI325, OR ClnO AND INSTALLED WITH -ax 1-1/I4' DAGGERZ PILILIPS WAFER HEAD CEMENT BOARD SELF DRILL SCREWS W/ COATING SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, AND WALL PANELS IN SHOWER AREAS. TERMITE 'REATMENT- TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDE5, INCLUDING SOIL APPLIED PESTICIDES, BA TING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED. PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." MECHANICAL AND HVAC: L ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE MECHANICAL ENGINEER AS AN. ATTACHMENT TO THIS PLAN SET AT THE TIME OF APPLICATION FOR PERMIT. 2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES (162 mm) DEEP AND 30 INCHES (762 mm) WIDE SHALL BE ENERGY REQUIREMENT SCHEDULE EXTERIOR WALLS (FRAME) R-13 EXTERIOR WALL5 (BLOCK) 4.1 FOIL ATTIC CEILING R-30 PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. 3 DUCTS IN THE GARAISE TING THE WALLS OR CEILINGS RAGE AND DUCTS PENETRATING RA SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN 26 GAUGE (0.40 ,m) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE INSTALLED ABOVE THE BASE FLOOD ELEVATION AND SHALL ALSO CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHA'_'- BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONS M14113. EXHAUST FANS AND VENTING, I. OUTDOOR DISCHARGE. THE AIR REMOVED BT- EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS, AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. 2- EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC,: CRAWL SPACE, OR OTHER AREAS INSIDE THE BUILDING. 3. DUCT LENGTH. THE MAXIMUM ALLOWABLE EXHAUST DUCT LENGTH SHALL BE DETERMINED BY ONE OF THE METHODS SPECIFIED IN SECTIONS IMI5024.5 i THROUGH M1502453. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET FROM. THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 25 FEET(T62 mm.) FOR EACH 45 DEGREE (0l9 RAID) BEND AND S FEET (1524 mm) FOR EACH SO DEGREE (16 RAID) BEND- THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. EXCEPTION - WHERE A CLOTHES DRYER BOOSTER FAN IS INSTALLED AND LISTED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH, OF THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE PERMITTED -O B E IN ACCORDANCE WITH THE BOOSTER FAN MANUFACTURERS INSTALLATION \STRJC- DNS_ WHERE A CLOTHES DRYER BOOSTER FAN IS INSTALLED AND NOT READI-Y ,'> ESSIBLE FROM THE ROOM IN WHICH THE DRYER 15 LOCATED, A PERMANEN- :DEN-IFYNG LABEL SHALL BE PLACED ADJACENT TO WHERE THE EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALL BEAR THE WORDS "THIS DRYER EXHAUST SYSTEM IS EQUIPPED WITH A REMOTELY LOCATED BOOSTER FAN." 4. PROVIDE BACK DRAFT DAMPERS AT INTAKE AND EXHAUST LOCATIONS AS REQUIRED BY THE CURRENT APPROVED BUILDING CODE. CODES FLORIDA, 810L,IDING CODE. NATIONAL ELPCTTR'--` '-:ODE, AND THE CITY OF-152PHYRHILLS OINANCES ISSUED: 02/12/2024 VERSION: 5.0 SQUARE FOOTAGE AW ASSET MANAGEMENT $0. FT. HEATED AREA Sq. Ft. MAN LEVEL TCO 5EGOND LEVEL 0 TOTAL AH4R SQ. FT. (SIaNCrawl) 1700 METHODOLOGY: ANSIZ76S2003 The total area calculated from the outside -to -outside of framing, including optional "I"ed basement options as shown. This area excludes stairwell at highest level above grade, garage, covered patio/porches. Ult -37 6p?oq � .� -I - M 5 02MI ANH DEVELOR'ENT DO NOT SCALE TVffH DRAIWNSS. VERIFY SUIT ORIENTATION WITH C 71ZACTOR AND SITE PLANS BEFG1g CLtJ5TR1LTI0N. THESE DRAUI,IS5 DO NOT CCNTAN SPECIFO mEOrmATION FOR ANY STSCTURAL ELEYIENTS (70 SE PROVIDED BY ENSIKEER Cf f¢CDRGJ ANY DI'..OI IOY (DIMENSIONS, ORIENTATION, ETCJ BETIFN RIESE DRAWINGS AND THE A.. IATEO DRAWING5 snd 51TE DRN ,I $HALL Be REFGRTED TO LLTIIRACTOR AT ONCE MD tV COTSTR 014 SHALL FRCGE`� 181TIL �CTED. THE CONTRACTOR AS'NEs RES? SISILITY TO YEE-A__ REWIREMEMS OF LOCAL B 1011 OFFICIALS I TO COMFLY WITH STATE &ILDIK'. CODES. 0 Ul o� O � n J � U � Q x a� N a>E wmmm FEVBDIS: CD O J � m � T �✓ I— � O J CIO Z `^ V, ` , N V L O/� CC w CO _ Z 00 J Q U Cc (n 0,02 cc E < Ul cli w u) I— LL. (n = C o ' } O 00 00 (D co N 7 L— WMI flE VERSION: 5.0 aNi 7 COVER SHEET all r/ CS11 aw -t OEVELCR ' SQUARE FOOTAGE CHART �Nm1LEONOEDR� 66 vEGON &ALONG ORIENTATIONIEAWITH CONTRACTOR A`rD SITE PLANS aEE°RE caasrRlcnoN TUESE DCIRC i DC NOT pOR A S TE TU II,POELEMENTMATION TOR ANY STROvi) 0 ELEMENTS EN5iI SER BE RECORDED BY ENSINEEE RECORDI. ANY DISCREPANCY (TUIE1451q15, GRIEMATION. EtG) BIA T O D DRAll11NG5 AND THE A.r'uCrIAiED DRAWINGSP-RTE SITE ELEVATION T ELEVATION T ELEVATION 'K' PLAN OPTIONS Ol 7 - AND r° carRACTDR AT one auo ND CQSTTd1C T 1°ti SHALL FRCCEED unill CTOR 661 T:a= CQ.RRA BUT AS0ATEE THE RESENEINT OF TC MEET ALL REWIALS INTO OF 19-T TWBiJLDIM STATE OFFICIALS tTD GLYPLY WITH STATE BUILDING CODE5. W 0 U � JN 6T O �o@ A(L C) ' LL n3 Q > W � u � MEW M%M wow a x REV6DM jo in R6fRdNMN9FN1pIT SQUARE FOOTAGE SQUARE FOOTAGE SQUARE FOOTAGE SQUARE FOOTAGE CONSTRUCTION AREA CALCULATION HEATED / CONSTRUCTION AREA Sq. Ft. MAIN LEVEL 1131 TOTAL HEATED/CONSTRUCTION AREA (Slab/Cfawq 1737 METHODOLOGY: ANSI Z7W2003 The total area calculated from the outside -to -outside of framing. including optional finished basement options as . shown. This area excludes stairwell at highest level above grade, garage, covered patio/porches. BUILDING ENVELOPE AREA (ALL AREAS UNDER ROOF) Sq. Ft. GAIRAGE 423 COVERED PATIO qb FRONT COVERED PORCH 30 TOTAL BUILDING ENVELOPE (SIeb/CMA 2286 METHODOLOGY Building Envelope Area: The total area calculated, including Heated/Construction area as calculated, and also including garage, covered patio/porches. MAXIMUM DEPTH = b1'-0" MAXIMUM WIDTH = 40'-0" "MAXIMUM BUILDING HEIGHT A.F.F. I 0 0 J m J Ln � H C O J L 1 Ccc V 0 z =3 V) N v O M LL w M Z CO J 0 U w— L 0 p M LL C�C C 0 - (L = } U) J j- J Ii = O p} cc v= r-w F to m N L_ mxwer. rrtE VERSION: 5.0 "W"", SOUAREFOOTAGE CALCUATIONS 81fff1 CS-3 BB A/C SECURED `JI.: ��/V ".s A�'✓ -.0 3 X3' PAD M0' 40 -0 CV_ �L XR( SEAL BE N STIR CT CCCM�i'LAN TH 5.;ILD,V- rnDE_ RE5 D N-IAL, AND CCON-Y 5L LDIIL D PARYEk._ 28 -0_ 12 -O" - ' -- - Fr- TOPSOIL, iRE_5, 57"lS, R'JO-S, ETC. FRO" ALA AR_AF WHERE _ON..TRUC71CN WILL OCCUR UNO. -- I =ILL SHAL_ BE FIRnL- COMPACTED. CLEAR SAND/C-AY MATERIAL. FREE OF ROOTS, ORGANIC MATTER OR OTHER INTEROR BEARING LOCATIONS 51-0ULD BE COORDNATED Im'-8"-4 WIT,-1 TRJ55 MANUFACTURER T STRUCTURAL ENGINEER I I PROVIDE SOIL TREATMENT AND vAPOR BARRIERS AT ALL SLABS (INTERIOR). II v f A70 5L,45 rO,NCRETE SLAB "IN, OVER 6 MIL VAPOR - 3ARRI- R. SLAB SHALL BE I f \ I vFR _EAN OC, ACTED 0 p �ILL W/ FIB RT"_5H w w I A C.1'.G SLAB W/ FIBER nESH Iq' e rv2 rcT 9I HVAC CHASE M - - - - - BASED ON ,,.. CONCRETE SLAB s pp I 4" CONCRETE SLAB MIN. OVER 6 MIL VAPOR BARRIER SLAB 514LL BE CLEAN f COMPACTED FILL W/ FIBEII _— �� �Il, �✓ X'y �I _L I I T,_II'/2� VI II 20,_3'� ELECTRICAL m m __ _ _ r7 AA8zD li 9' �I o'I _ w W II I I o c01 19'_2" I 13 -4/4' 2'-6Y" 4'-Im% - B C- - - 13 c / III 1 •FU \ ` -_-_.,.yamTj d �I CD CRE SL B 4" C CRETE SLAB MIN_ OVER MIL - \ VAP BARRIER SL�48 SHALL BE VER AN COMPACTED, FILL W/ FIBER', m \ 120.-0�� z � m SLAB � I w g 'P.JN'GN'F �'. U- 4 ^NGcETE SLAB IN_O�R 6 IL W/ Fib F Ni VA OR BARRI R SLAB L B� V R _AN C T'MPACTE I' L W/ - - FIBEg'ESH 2'-0" 16'-0" OPENINC, IS'-4'' I 8'_4" _ 12' 4„ 40'-O" OVERALL 1:�, SLAB PLAN - ELEVATION',' r-MkTsme ff 1- (Tuen QBP — D_- =LOR1EN7 DO NO- `..GALE THESE DRAWNGS Y=F RAC7 !HL- ID 51 ATON - CJ:'RKTCR AID SL- P_cN5 RE" -ORE C',y.5-2L".P:. 7✓ 5E DRW E^ DO OT CC47AN �GIF.0 �azGTia.'LR A r RECORD) 3' GIM1EEE 6 „'„Fr'. AN` -17,7 PANCT mrE` -- oa_ W 5 u �A DDRAWI-5 rAa5Tc �RNL M1L }IAL H REPOR?cD TO C.. TRACTg A? ONCE MID NO CON, 57—T10N 5HAL_ P -EED IN;TIL CCR CTED, THE G' TRACTOR AS`A➢'1E5 THE RESPONSIBILITY TO I'EET ALL REQU1 REMENi5 CT LOCAL WILDING OffK ALE / TO COLY WITH 5TATE WILDING CODE5. U � ^ JN 6T 0 0 Z m N Q) >�� r1 w :T Q x =a Q� FEV6UN3: 0 0 N m L T CID W F O � I ' Z � V) V `/ N 0 _ WM Z co J U Q CD -' O 0 -, cc E S L W — }� H 0 } C va CIS w r- �- m N F- L— J — VERSIOW 5.0 '� FOUNDATION - SLAB PLAN Wt F-1.0 L-00 PLAN NO ES TJOOEfl TOFAu cL PROVIDE 1/2 (MIN MUM) GI - SUM BOARD SEPARATION AT WALL5 AND 5G" TYPE X CEILING5 N THE GARAGE ADJACENT TO THE MAIN HOU8E AND ATTIC AREAS_ 145-, iNG MACHINE 15 ALWAYS LOCATED LEFT OF THE DRYER UNLESS NOTED OTHERW15E. CLO$ETWAII ALL EX.ER:OR W4LL5 ARE DRAGN AT 8" CMU UNLE55 NOTED OTHERWISE. SPIN ALL INTERIOR AND COMMON WALLS ARE DRAWN AT 3 1/2" UNLE56 NOTED O LERW15E. PL,GIVI �� YWOOD Ft W HEADER FOR'1R5- FLOOR 15 AT 8' O" w/ 9 -CLG, + SECOND FLOOR 15 AT 1'-0' L/ 8CLG ANDR IL' EIGHT SHAL1 _ BE 36" MEASURED VERTICAL"FROM THE NOSING OF THE TREAD. ) DENOTES GRE55 WINDOW II I OTO�OYf-0' IL it J W3lf •""'_" I ElEVA1ON oI a'sax vunEs=e P<ax B HVAC RAISED PLATFORM FR' MARY 5AgH E -4" CLG VINYL PLANK 40'-0" OVERALL 28'-0' 3'-10" 9'-10/" 3.10, 25 5H (•1 a, 25 54 f•) 25 SH 1A„I 75 5H �R'IMf�R F&MIL Y SUITE ROOM 9' 4" CLG, 9'-4" CLG VINYL PLANK VINYL PLANK m I m 34"x60' SHOWER H/ OPT. TEMP GLA55 r--ENCLO5URE I a A/C SECURED SO SXT PAD SET SOFFIT J 10'-8'. AT 8' 0" LT. 4'( -I OOVERED FAT�O 9'-4" CLG AFF. CONCRETE E c° a II 9 7'-3y2' a'-9„ q l 25 SH ALL I I �ININ� ROOM %�-� VINYL PLANK F� l LJ 1. $INK W/DSP = v In KIfi�N�N c ' timl `L_ -emu m 9'4"CLG 8'011HVINYL PLANK . S -- 2468 r ED 4`LI '- Y� '� 3�I' q'-5-y1 9r HEADE' 12 3RANGE W/MIGRO J4NTRY •C/ 1 57 5H R YER - I� LOCATION 1 D m LhgjVp �Pil)N- z 9'-4" CLG YV. .I�. G o a ? _ VINYL PLANK rc J � � o I - 9'-4" GL_ � - 9' qCI G .Aw m VINYL PLANK "T IIVMYL PLAMK inl' Q vm 0 I W..2. O, 1 s I N I g' a" S"IDy' 4 3 OPi_ GARAGE ILALLS COMMON WITH LIVING-- T-10" �OLLARD, AREA MUST HAVE I/2" DRYWALL 2� I1R+5 2'-4" fTYPJ SEPARATION (MIN 2'd MIN FIRE - = 54'x27"FULL'' HVAC ON RA15EF HVAC 15) SH. �--0OlUN STAIR'S PLATFORM _ CL05ET PER DETAIL S fiHU _ - - lz 3'-Ty" 5'-4y2'' UT rn B o B 0 Tl>3 9'-4„CLG OARAOE 0 I VINYL PLA B , 9'-4" G_G AFF_ FO - CONCRETE 9'-4" CLG 30X60 .LJI INYL 'LANK z�a TI.6/SHOWER e �i ELECTRICAL g �' RN5 --------- ' — — — — — — — — PANEL WALLi ---/ bb _ 19'-2" t� 3'_44 l'_8ye" °�m`e�ROOM 2 1 4 H3 VINYL PLANK Q 16'-0" x T' 0" ON_ GARAGE DOOR GfPs%� FIRST FLOOR PLAN - ELEVATION II' WAiE,A'"o(1W7) SCAM„~ -I n FF. 0 I L-SET SOFF Ai IT �� 8'-O" HT � >3 40'-0" OVERALL h 25SH0) 4 25 5H (0 Q03'Phu DEVELORIENT CO NOT .,GIBE THESE TATO NGS. vERI. KACT PG ORIENTS T`L WN5 CONTRACTOR AND E THENE 5DRAW CGN.,T NO ION. THE E DRAWII' DONOT FO A 4'£GF.G1A,E FlENI ORa F r STfd1 VIDEO ELEMEN'ETO F PROVIDED BY )ISCREER C REENSiONANY ESCREPANcC - (DIMEN61ON5 ORIENTA'ION, ETT ASSOCIIA THESE 4WING5 .,AND THE ASSOCIN ED DRAWIK.5 and/or SITE DRAWINGS SHALL E REPORTED TO ' CCNTRACTORA ONCEAND NO LON5717ION S AL� FRCOEEC WT L CORRECTED. THE CONTRACTOR A55UNE5 THE RESPGN5181. Y TO MFF- A:_L ,cEMIRE = NTv OE LOC L BUILDING CF CIA & t TO COt1PLY WIITH 57A7E „ BUILDING OODE5. ff d Q� U � J 0 o@ > m j {--1 W � U Q x a� REVSM: O Q (D J ,W YJ W I— O L Ca rJj V �z V) N V WLo O Z co _ co Q U oEC U) 000 rtr LU E Q l co Y I— LL 0 2 LL 2 O V EL W F- Co r N F L- J AF VERSION: 5A FIRST FLOOR PLAN FAT. -1.0 - jlo I I� J WAMSGML-It,c.,a(1,x,T/ ATTIC VENTILATION: (300 5Q = A-TC, SFACE " 50 FT VENTLATIONI C41CULA71ON5 REFLECT 50% R'.DG-E AND 50% 5011 YM1'S 228l 5Q FT UNDER ROOF A'TIC / 300 SO FT , 50 FT - TO SQ FT VENTILATION CIF -RIDGE VENT = ICA 50 'N EACH (4' VENT) SGF-F!T VENT ; 9 SQ IN EACH III SQ FT x SQ% = 3BI SO FT HIGH, 36 SO FT LOW HIGH VENTING 3BI 5Q FT x 144 5Q IN •54864 5Q IN REQUIRED (6) OFF -RIDGE YEN' x 104 SO IN 2624 80 IN LOW VENTING 331 5Q :. x l4d 5Q IN -54861 SO IN REQUIRED 54864 / 9 - 61 SOFFIT VEN'S !CONTINUOUS VENTED SOFFIT; 61,� 6 2 H aR` IM,.�I_E RQ 6' FREZE 612 -ITCH Ex RIOR ARC:1 5HINGL= S PLASTER ON ROOF (TTP) I w� FRAME I � — O FLR CEILING �!. ,. JN.EE- WINDOW LINE�L -I Iu� Q ( L W- 6R1RAiSED 3T0000 - �� 6" HEADER TRIM COACH _:G14T PER Ali . coSPECS 4 RAISE STUCCO RIM N MN 'Iq;S C.A ` �n O SIDE .ER ca-+-LM�n TRI r-.ai ELEVATION FRONT N I 0 0 wAui A'.,Pn,x,n me,µ l'CP q s;_I_R G= �6 — - _ U;:.NDOYU _iNE� v Oi m m FIN FLR ELEV 02031 AMP' DE VELOFn_ 7 DO NO5CALE'HE5E RAAI-. r_z',F, BALDI. ORENTAT':LN w.rH COV'RAC=OR A 5,7E PANS ORA5 -DO NO7(, 7. FO14- ON SZC-'uRA_ '1+T5 (TO 3E �Cv'DED 'T ENCMFER x R<GOfLi i. 4N' DIx'.(`?ANCr A--_ry THESE 4,A LS 6VD ATE A-- _A iE'.. DRAH REa ,E 51TO DRAWIT 5V.',:L:_ 3E RvF AND N TO C NBN C?OR AT CMCE AND NO CCNJNTI ON SHALL ?THE '.MTI'_ COS�C ,D. THE C5FON51 TOR A55UMEE THE RESPCN51,5 OF TC MEET ALL REOIIIRE,SNtS Cf LOCAL EUILDIIYa OFFICIALS / TO CCMF^_Y WITH STATE &iILDINi CODE5. u r -A _A � zap O` � Q W Q LH N wLL F—I w � u � Q 5x Q� N IfiSl9E�0E 1 REV6DN5: O O J N m J LID H C 0 J 2 C6 I 0 Z N v v O W; Q U W— L O a0 LLJ } W J F— M _ 0 �' 00 2 GD 00 w r N F_ L J OMtlYIICI: fIE VERSION- 5.0 flummE FRONT/REAR ELEVATIONS & ROOF PLAN 9ffT� -3.10 61� 12 A' VEN? 4' VENT 6/12 PITCH ARG� 5HINGLE ROOF 7--) 6 2 �6 12 12 12 6� 6/12 PIi01: ARCH SHINGLE 17 �6 6/12 PITCH ARCH 5HINGLE ROOF (TYP) � Ist FLR CEILI16 WINDOu L1NE_ 0 mI CEMENTITIOU55T000C" PER COMM. 5Pc05. FINFRELEV � LEFT SIDE ELEVATION T >xxr=+Ps+�alnen scuF:+N++n@aeq 4011 — DEVEL—EN DO NOT ' -..GALE THESE DRAWINGS. v RIFT SIIILD� ORIENTATION WITH C ,RAGTCR AND 5TE PLANS RE -ORE OON5TR V 71G THESE DRAW 5 W NOT CON7AN SPEGFIG INFORIATION FOR AN, 5TR TLL FLFMENT5 (TO 5F :SRJVlOED 5r ENGNEER Cf I?:C'; ANY DISGREFANCI- (D1rEN5ION5, OREKAT',ON, EC BETWEEN THE`.F. DRAWIIfS AND THE A55CCIAlED DRAWIN 5 ar�d/or 517E DRAWINGS SHALL BE REPORTED TO ,_,"CTCR AT ONG AND NO CON5'CTICN 5HALL PR :D '1T CORRECTED. THE AC CONTRTOR A55.A1E5 THE RE5PON5rEYLI71 TO MEET ALL RECdIIRE W5 CF LOCAL WLDING L 'CIALS t TO COI'PLT WITH STATE _WILDING CODE5 -j W J J� 6T o IV w � wLL� w c fF--11 W � U � Q 5� Q IL F � V ACHE .119�1 FEYSM: C) Q J � J L W LT I— O J L Cc I z/ V� /J V U N Lo O W Cl)_ Z Cl) VJ O Q � oL E � i Cn co _ O 0M 0 00 2 CO n w m N F L J dW1 - FAE VERSION: 5. *mr-- SIDE ELEVATIONS *Mt -3.11 Sj L J \!' JAI' w -SAP—' S-RICTLT 4RC,TES-' RA - R=FER -C n =0R RE YF^.R'IAT''.ON. -'CNS 51` A. -_. _'V470NS 4.,r uEN US K. :XT R'.OR W _S nCOLUMN DETAIL �,µti,alnx,T� Bcue,rr.,-0'RaoA �I6 N'.AILA''iON PER=BC 111 ENERGY AO- .-IT— WITH FERT"T PPLICATION FOGKET W.I.G. �� LAUND. OFFIGE : PAC-ED TER'I' -RE4TED SOIL wN4POR BARRIER BUILDING SECTION mW FAMILY ROOM BUILDING SECTION SW sale 1,!'.1 d'I„A,%) BtvAl[NI TSNowN •AUElEVA7DNs 9MAR sale,lr�,uRaaq saveLn,N`OUM atvAMN TSNOWN-AUBP/ATDWSMM swe =-rpm6 12 6� PRE -MANUFACTURED TRJ55E5 KITCHEN COMPACTED, TER'IITE TREATED 50i- w/VAPOR BARRIER BEDROOM 3 ---- Ist FLR CEILING WINDOW LINE III I �I ------N R.L`— — l FOUNDATION l5EE STRICAR.' L -_AN) INSULATIGN FER'� AND ENE-iT 6/'2 PITON =0 E EE IT-E7 JI`L PE IT ARC'.I. Slil:✓_LE n _IOl-'ON ROP (TTP) - — — — _ __R WINDOW _INE FOYER FORGH C, i — — — — F FLOOR —J — FOUNDATION BEE 5 T RXTURAL PLAN) 4RMI A vEv L­ DG`O ILC E TORB DiAlL ,T. 'Ea;ILCMG GEE4TA'.. LATH ;ANi'eACTGR 4\TL S��_ PLANS JRNiI� CC \G- CGN-A�\ ate- CV-f.12'A 'JY "-^..R AVT E �C.'XCJ1 A4T 015GRB?A^LT 'C�'eti5THE CRINTtiImo;._i."T ,55c,:N i1-E4 DRAI.!K5 AID THE AEa ,"S _ DRAWINGS TE SITE CR4WI,�.S STALL 7E N-PAID N TC COJtRAGTCR Ai AONCLL AND NO CGNSTR1L C SHALL , THEEED IMTIL CGRRE55ZE HE CGNTRACTGR A5511MEE THE eE".-P1F,151oILITY -G MEET ALA R ICA REMENT5 GF LXAL SULDINT OPICIALS 4 TO C FLY WITH STATE EWLOM- _FS. ^- W U � w � m 0 LLII � w � �a ^ LU c u w U Q x Q� MEWDAM WOW O O J � m J H O J L CQ 0 z VJ U V O Wi z cM7 U l QQ (L�C_- On /) LL E(n ' W = �' U7 = Lu co N 7 L- _ 1 VERSION: 5.0 81Hf NYE BUILDING SECTIONS NEU -4.0 r i 6 __EGTRiGAL LEGEND GAS G-AS LINE RECESSED CAN LIGHT � Cy COLD WATER [} FLU5P MOUNT LED C� ELECTRICAL PANEL Q WALL MOUNTED LIGHT ELECTRICAL METER n°r WALL SCQNCE DISCONNECT 5WITCH FLUORESCENT LIGHT BULB SWITCH FLUORESCENT LIGHT w/ 2 BULBS 3-WAr SWITCH r�p VAPOR PROTECTED LIGHT 4-WAY 5WITCH EXHAUST FAN DIMMER SWITCH EXHAUST FAN./ LIGHT J BUTTON EXHAUST FAN w/ HEAT a ,IGAT DUPLEX OUTLET 5D SMOKE DETECTOR QUADPLEX OUTLET ® CARBON MONOXIDE DETECTOR tl SWITCHED DUPLEX (� `T' THERMOSTAT OUTLET t I.®'e FLOOR OUT DIRECT WIRE GFI OUTLET T PHONE JACK V. p-'I WATER PROOF GFI V" OUTLET T MEDIA JACK - � CEILING MOUNTED T(J� CABLE TV OUTLET OUTLET Y J � 220V OUTLET DOOR CHIMES CEILING- MOUNTED ® SECURITY PANEL LIGHT HANGING CEILING FLOOD LIGHT MOUNTED LIGHT n I I C= =-D CEILING FAN CEILNG FAN m/ LI HT L ELECTRICAL GENERAL NOTES SW'. CHEF 5 TO BE 45 AFF. RE EP"5. "O BE 12" AFIF - 42' IF OVER A COUNTER ALL WIRING TO BE IN ACCORDANCE Wj7H NEC; ARC FAULT CIRCUIT INTERRUPTER PROTECTION SHALL BE PROVIDED 45 REQUIRED IN NEC 210.12(A) AND SHALL BEINSTALLEDALL BE IN A READILY ACCE55BLE LOCATION. ALL SMOKE DETECTORS 5HALL BE HARDWIRED INTO AN ELECTRICAL POWER 5OURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DE EC -ORS - GROUND FAULT CIRCUIT INTERRUPTER SHALL BE PROVIDED 45 REQUIRED IN NEC 2108(A)AND INSTALLED IN A READILY ACCESSIBLE LOCATIONL IT 15 THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK 15 :N FULL COMPLIANCE WITH NF.P.A. TOA - NEC AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES - PROVIDE INTERSY_ EM BOND:NG'REMINATION AT SERVICE LxATION PER NEC 250S4 LUMINI4IRE5 IN CLOTHES CLOSETS SHALL BE INSTALLED PER THE PROVISIONS Or NEC 410.16(A) 1 (5) RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED 100% OF THE LAMPS '.N PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS REFER TO ENERGY CALCULATIONS FOR ADDITIONAL INFORMATION. PROVIDE THE REQUIRED CLEARANCES AROUND PANELS AND DISCONNECTS IN COMPLIANCE WITH NEC 11026. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC 40612, THE BRANCH CIRCUIT SUPPLY'NG THE RECEF ACLE(S) IN A GARAGE SHALL NOT SUPPL Y OUTLETS OUTSIDE OF THE GARAGE AND NOT LE55 THAN ONE RECEPTACLE OU-LE' 5HALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE. AFCI PROTECTION - 21012 (B) DWELLING UNITS. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNITS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DEN5, BEDROOMS 5UNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOM5 OR AREAS SHALL BE PROTECTED BY A L'STED AFCI, COMBINATION TYPE. INSTALLED TO PROVIDE PROTECTION OF BRANCH CIRCUIT. EXTERIOR GARAGE 200 AMP METER MAIN COMBO MCI \ J 200 AMP MAIN LS INTERIOR PANEL 4/0 AL SER CABLE GROIJNDI,NG ELECTRODE SHALL COMPLY WITH 5EG 25052 ELECTRICAL RISER D'AGRAM N.T.5 STRUCTURED — MEDIA CABINET TO INCLUDE CAT5/6 COAX, U58, UP ROUTER SPACE AND POWER VERIFY EXACT REQWREMENT LOCATION AND MOUNTING HEIGHT PRIOR TO INSTALLATION `KEVL ,6PT. DEDICATED 50 AMPS (14 -50 NEMA 240v) !F REQUIRED BY CODE GrCrl A/C D15C. -FLOOD LIGHT R.I- B m c� \ I &220G I _ I ALL u J® �� \ v T \ )v FIRST FLOOR ELECTRICAL PLAN - ELEVATION'I' 420 1 AMP DEVELOPMENT DG NOT SCALE THESE DR UIN6S. VERIFY FU1LDIIL'- ORIFMATICN WITH CONTRACTGR AND SITE PLANS BEFORE CON5TF I IOK THESE DRAWI S D0 NOT CONTAIN STEGFIC AL ELE W FGR ANT sTRolio C ELEMENTS (TO FBF PROVIDED BY ENGINEER CP REAC5CEN51ON ANY ENTAT N, CY ETC (DIMENSIONS, DRAUATGN, ETC,) A5T58IN THE DRAWIN:a, AND THE R,UIN,7ED DRAlE RE and/or 517E DRAWIM_'-,5 SHALL BE REPORTED iG CONTRACTOR AT QJCE AND THENO CONST L CxRECTEDJ SHALL PED UNTHE COR. GGN7TRACTGR ASSUMES THE i FBTENT5 O T TG MEET ALL REIX.IA-5 1 75 GF LOCAL &IILDING OFFICIALS U TO C/JMPLY LATH STATE SJILDING CODES. C) J � m J LCD H CF O Cc 1j ` ' z U w " 0 _ wP Z M J Q U � N w� O o, MC/) LL E c IW­ I— LL cn _ OfoD � } CID 0= O co N HOUSEWRAP BARRIER R, JOINTS) OVER EXTERIOR SHEATHING PER SPEC -SF TO OVERLAP RUBBERIZE FLASHING RUBBERIZED THRU-WALL FLASHING, EXTEND UP 8' VERTICALLY (C' MN VERTICAL PROJECTION ABOVE SUBFLOOR), TRN TO OUTSIDE FACE OF BRICK HOUSEWRAP BARRIER RAPE ALL JOINTS) OVER EXTERIOR SHEATHING PER SPECSHEATHNG TO OVERLAP RUBBER _ BLDG FELT BETWEEN FLASHING _ USEWRAP BARRIER AND - :K VENEERAYPICAL UP RUBBERIZED THRU-WALL FLASHING, EXTEND UP Ir 15# BLDG FELT BETWEEN VERTICALLY (4- MIN _ HOUSEWRAP BARRIER AND VERTICAL PROJECTION - = BRICK VENEER -TYPICAL ABOVESUBFLOOR), " TRIM TO OUTSIDE FACE CONTINUOUS MORTAR NET EP HOLES AT COURSE OF BRICK )VE FLASHING - 24' O.C. RIZONTALLY o WEEP HOLES AT COURSE THRU-WALL FLASHING HOUSEWRAP BARRIER - REFR TO DETAIL FOR CUTTING COORDINATE 15N BUILDING FELT BARRIER AT WINDOW OPENING. APPLICATION WHERE BRICK VENEER IS SPECIFIED - FOLD HOUSEWRAP DOWN OVER HEAD FLASHING AND APPLY CORNER PATCH EXTENDING I"MIN. BEYOND BARRIER CUT --INSTALLHEAD FLASHING OVERLAPPING WINDOW FLANGES A MN. OF 7-INSTALL UNDER HOUSEWRAP APPLY JAMB FLASHING OVER SIDE WINDOW FLANGES -MN. I" ABOVE MEAD AND 3"OVERLAP ATSLL *HEAD WINDOW OVER SEALED AND HASHED PREMANUFACTURED SILL PAN BEFORE TAPING - FILL _ ENTIRE INTERIOR PERIMETER GAP W / NON -EXPANDING FOAM OR SEALANT TAPE SEAM OF OVERLAPPING PLASTIC SILL BOOT - PREMANUFACTURED PLASTIC SILL BOOT unur��ur oft�r.nui+ r-B A r%l BILT►ILn NOT TO SCALE -- -_ GABLE END WHERE OCCURS REFER ELEVATIONS AND DEALS 12 TYPICAL ROOF COVERING PER SPEC SEE ROOF/ PLAN / TYPICAL ROOF TRUSSES PER SPEC S \ TYPICAL ROOF INSULATION PER SPEC TER ROOF N DRIP EDGE PER CODE & COMM. SPEC -.- ..:...__i RPOM IYP. M. CLG. TFFU._ KNS J MATERIAL -PER SPEC / FASCIA PER CODE 6 COMM. SPEC. REFER TO STRUCTURAL -1 TYPICAL SOFFIT FD EH PER SPEC FOR TRUSS TO WALL TIE BEAM - REFER STRUCTURAL CONNECTION TRM PER ELEVATION PER SPEC B' CMU BLOCK REFER STRUCTURAL TYPCALSTUCCO FINISH ON BLOCK PER SPEC TYPICAL NIEFKM WALL FINISH AND INSULATION OVER BLOCK PER SPEC WAINSCOT PER ELEV. PER SPEC VERIFY FOUNDATION PROFILE VARIES BY TYPICAL BASE LOCATION / CONDFDNS PER SPEC REFER STRUCTURAL VERIFY DEAL FOR TERMINATION WALL FINISH AT FOUNDATION PER ELEVATION A MATERIAL � �L REFER TO PLOT PUN FOR SLOPE r, CONFISURATDN TYPICAL 1-STORY WALL SECTION NOT TO SCALS ABOVE FLASHING - 24' O.C. SOLD GROUT BEHIND HORIZONTALLY FRNW COURSETY FOUNDATION POURED FOUNDATION WALL BRICK LEDGE THRU-WALL FLASHING @ BRICK LEDGE NOT-C SCALE FRAMING SYSTEM BRICK ROWLOCK - REFER TO ELEV. BRICK SOLDER (OR) 3 BRICK COURSES -REFER TO ELEV. THRU-WALL MEMBRANE HASHING WAINSCOT DETAIL NO- TO SCALE HOUSE WRAP OVER WALL SHEATHING - PROVIDEENOUGH OVERLAP TO COVER METAL RASHING AND THROUGH -WALL FLASHING TAPE OVERLAPPING SEAM SIDING PER SPEC 17 BEM METAL RASHNG- EXTEND 8" VERTICALLY EXTERIOR SEALANT I CAST STONE SILL OR BRICK ROWLOCK- RffHt TO ELEVATION BRICK TIE WEEP HOLE THRU-WALL MEMBRANE FLASHING TO FACE OF BRICK W/ MN. 24" VERTICAL LEG. LAP UNDER BUILDING WRAP. 7/8" STUCCO OVER FRAME (SHEATHING, 2 LAYER W.R.B., LATH AND STUCCO) - PER SPEC - PEEL B STICK BRIDGE FLASHING, SHINGLE LAPPED OVER STUCCO ACCESSORY VINYL PLASTER DRIP SCR® - PER SPEC INSTALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS CAP SHINGLE - DO NOT STAPLE OR NAL E� ROOFCEMENT SHINGLE ROOFING ON ROOFING UNDERLAYMEM- PER SPEC PEEL 3 STICK BRIDGE FLASHING. OVERLAP ON TO ROOFING UNDERLAYMENT 67c6" CORROSION RESISTANT BASE FLASHING - PER SPEC PRE-ENGINEERED WOOD TRUSSES SEE STRUCTURAL AND TRUSS DRAWINGS FOR SPACING AND CONNECTION DETAILS NOTE ALL ROOFING MATERIAL (PER ELEVATION) SHALL BE INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTION. VERIFY ROOF SHEATHING WITH STRUCTURAL DRAWINGS ROOF TO WALL AT RAKE 2 STALE: 3"- 1 -0 7/8" STUCCO OVER FRAME (SHEATHING, 2 LAYER W.R.B. LATH AND STUCCO) -PER SPEC PEEL 3 STICK BRIDGE HASHING, SHINGLE LAPPED OVER STUCCO ACCESSORY VINYL POSTER DRIP SCREED - PER SPEC INSTALL PER MANUFACTURERS INSTALLATION NSTRUCTIOW "L" FLASHING CAP SHINGLE - DO NOT STAPLE OR NAIL ROOF CEMENT 6'W CORROSION RESISTANT BASE FLASHING RYP) PRE4NGNEERED WOOD TRUSSES SEE STRUCTURAL AND TRIGS DRAWINGS FOR SPACING AND CONNECTION DETAILS TYPICAL EXTERIOR WALL ASSEMBLY - SEE STRUCTURAL DRAW - NOTE. ALL ROOFING MATERIAL (PER ELEVATION) SHALL BE INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTION. VERIFY ROOF SHEATHING WITH STRUCTURAL DRAWINGS ROOF TO HEAD OF WALL - SHINGLE 62r. A— DEV'E_OP'-ENT DC rs SCALE _`FsEE nRG s. VERPYE ILDRY: C,E!EN'Ai2X jni- cartRncT AND E TE_ aEE col6iE.L-10d. •vPsr ANT sRcr:RA: E:� a-5 rra E=c D�ANY as Ew.c rD:"+=NSIONS, C"i2r'AiIpJ, ETGi F�"LET ".Ex DRAL'RGS AWD i=E DR. ' I IATED L_ El FEECR-t SITE DRFWIC:S'TI ATT �- MD 1 r0 Cq�'iRACT IO AT AU STUD NO CONSTRJCTILN SHALL PRGCEED aTIL CORRECTED. T CONTRACTOR AETHE RESPON5181LITY 70 i0 "tTlEE5 T ALL FlM f1r�ENTs of LOCAL ewLD!Nc- CFFICIALS �'O COMPLY WITH STATE BUILDING CODES C) C) J m Lo T V/ cu O J " N 0 G ' z v co /�� C `/ N O W � �_ Z 01) J Q U IQ) III LC L _j JO w u) O � rN (� ) 7 J DRIMIY: FM VERSION: 5.0 >pfffL11E MISC. DETAILS 9iffTIL -3.2 EXTERIOR INTERIOR FIBER CEMENTSDNG OVER TYVEK' OR EQUAL I HOUSEWRAP OVER EXTERIOR 6" WIDE, SELF SHEATHING AND FRAMING I ADIi&NG, SELF PER STRUCTURAL DWGS. —', ,{ HEALING WATERPROOF ly- MEMBRANE 6' WDE SELF ADHERING. .: SELF HEALING WATERPROOF ,1 SHIM SPACE PER MEMBRANE UNDER 2 LAYERS -I MANUFACTURE' OF BUILDING PAPER. RECOMMENDATIONS TAPE/SEAL CORNERS r II�� .� .. CORROSION RESISTANT CAULKING -TYPICAL \ METAL HEAD FLASHING WITH WRAPPED ENDS--'- WINDOW ASSEMBLY EITERIOR GRADE SEA" INSTALLEDWITH OVER BACKER MATERIAL SEALANT SE - - BEADCONAT FLANGE PRIOR TO BEAD AT FUS V INSTALLATION NOTE WINDOW ASSEMBLY TO BE FASTENED TO STRUCTURE PER WINDOW MANUFACTURERS NSTAL ATDN REQUIREMENTS AND RECOMMENDATIONS HEAD AT FRAME WALL SCALE. 3"= 1'-0' HORF UP SIDING NSULLt3) fNR III 11�, FOR HMG. PER MFR'S INSTRUCTIONS o/ BUILDING l STRUCTURAL DETAILS PAPER o/ SHEATHING AS Y GYP. BD, OCCURS )PER STRUCTURAL DETAILS J ) I1?III STUCCO FLASH COAT o/ FOAM TRIM SEE ELEVATION 2x6 V 1zWD. TRMr—� ti F `TRACK ASSEMBLY SEALANT 2z RB DR. JAMB JAMB STRIP GARAGE DOOR 1 1. OVERHEAD GARAGE DOOR JAMB SCALE'. 1 V2"= I' 0" EXTERIOR INTERIOR SELF ADHERING, SELF HEALING WATERPROOF MFMBRANESLL WINDOW ASSEMBLY 16TALLED WITH NTINUOUSRANGED SEALANT DAM -CON MN. AT r� BEAD AT FLANGE PRIOR TO UP JAMBS � 1 INSTALLATION S ERIORGRADOol — CAULKING -TYPICAL SEALANT BACKER MATERIAL �. 1X2 WOOD DAM FIBER CEdENTSDNC OVER TAW OR EQUAL INSTALL PLYWOOD HOUSEWRAP OVER ,-� PANTED BUCK BEHIND EXIERIORHEAIHNG �� AND FRAMING PER WNDOWSAT DORMERS. IYP. STRUCTURAL DWGS. NOTE: WINDOW ASSEMBLY TO BE FASTENED TO STRUCTURE PER WINDOW MANUFACTURERS NSTAUATION REQUIREMENTS AND RECOMMENDATIONS SILL AT FRAME WALL SCALE: 3"- I' 0" HORR LAP SIDING INSTALLED PER MFR'$ NSTRUCIDNS o/ BUILDING PAPER o/ SHEATHING AS OCCURS (PER STRUCTURAL DETAILS) __.... LAP BUILDING PAPER MN r o/ GSM DRIP EDGE RASHING ICE R WATER SHIED AT CORNERS . EXTEND 6" UP WALL — WOOD TRIMSEE ELEV FOR SIRE ---- 2x RES DR. HEAD / GARAGE DOOR GARAGE DOOR TRACK FOR FRMG. PER STRUCTURAL DETAILS GYP. BD. HF�xb Fv OVERHEAD GARAGE DOOR HEAD SCALE. � 11/2 I'-0" EXTERIOR FIBER CEMENT SIDING OVER TFVEK' OR EQUAL HOUSEWRAP OVER EXTERIOR SHEATHING AND FRAMING PER STRUCTURAL DWGS. 6' WDE SELF ADHERNG, SELF HEALING WATERPROOF MEMBRANE OVER BOTH LAYERS OF BUILDING PAPER EXTERIOR GRADE SEALANT EKTERDR GRADE SEALANT OVER BACKER MATERIAL 6" WDE SELF ADHERING, SELF HEALING WATERPROOF MEMBRANE INTERIOR SHIM SPACE PER UANUFACTURB' 'HCOMMENDATIONS .AULKNGTYPCAL WINDOW ASSEMBLY NSUILED WITH „ONEALOUS SEALANT 3EAD AT FLANGE PRIOR v TO INSTALLATION NOTE WINDOW ASSEMBLY TO BE FASTENED TO STRUCTURE PER WINDOW MANUFACTURERS INSTALLATION REQUIREMENTS AND RECOMMENDATIONS JAMB AT FRAME WALL SCALE'. 3"= " 0' LAPS SONG MALL PER MANI o/ GRADE 'D' BLDG. PAPER o/ SIRUCT. SHEATHING SEALANT i WD TRIM SEE BEV. FOR SEE TYPE YY BLD'G PAPER o/ MOETOP (,C MN. LAP) o/ WINDOW FLASH SEALANT_ SLIDING CUSS DOOR FRAME SLIDING GLASS DOOR HEAD SCALE:3 1'-0" 02021 AHH OEVELORIENT 00 NO KALE THESE DRAWINGS. ""Y & ILDING LRIENTATICN WITH —TIEA.CTOR AND SITE PLMIS 3EFCRE CCN57R11CiM THESE DRA [,S5 DO NOT G - IN 5PEC'.FIC Y02-!AT',ON =0R AI:'" P , IIOED 5' E 1:=ER OF RECORDI. ANT Df5CFEPNJCY `-NSIOeS,—ENTATON, ETa BETIIEEN T E5E DRA INGS AND THE A'„WCCIATED DRAWINGS andior SITE DRAWINGS SHALL SE REPORTED TO 1 _TIC AT ONCE AND NC CON5�C T 10, S!AL'_ FRCCEED :TUT L �CTSO T1 C TRAC?CR A5S,1'.E5 '-E 115PCNS5 LI' TO'IEET ALL ,1�75 OE LOCI �ILE- OFICIALs . TO C-PLY WITH 5TITE EUILDING CODES. Q� @ U � ^ -1 'D 0 Z @ J w m ^ � c u w Q W m Q @ INEwmm ourAm 0 0 � MJ W J Ln (Q O I `Cc IL z VJ N co O LLJ Z co co Q U CD LEI L 0 EC 0 � � w ELL — UJ _ O IL o} O "td Eli00 �- (D M N F L WMW W- FAE VERSION: 5.0] MISC. DETAILS Wf -3.4 GENERAL STRUCTURAL NOTES: 1. ALL WORK SHALL CONFORM TO THE 2023 81h EDITION OF THE FLORIDA (INTERNATIONAL) RESIDENTIAL CODE AND APPLICABLE COUNTY CODE AMENDMENTS. STANDARDS LISTED IN STRUCTURAL NOTE SECTIONS REFER TO THE VERSION AND EFFECTIVE DATE IDENTIFIED IN THE REFERENCED STANDARDS CHAPTER IN THE GOVERNING BUILDING CODE NOTED ABOVE. 2, THE STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS. SHOULD CONFLICTS EXIST BETWEEN THE DRAWINGS AND THE STRUCTURAL NOTES, THE STRICTEST PROVISION SHALL GOVERN. 3. THE STRUCTURAL DRAWINGS FORM AN INTEGRAL PART OF CONTRACT DOCUMENTS. WHICH INCLUDE ARCHITECTURAL. STRUCTURAL. MECHANICAL, ELECTRICAL, AND CIVILiSITE DRAWINGS. COORDINATE THE STRUCTURAL DRAWINGS WITH THE REQUIREMENTS SHOWN IN THE OTHER COMPONENTS OF THE CONTRACT DOCUMENTS. 4. TYPICAL DETAILS AND OTHER SECTIONS/DETAILS APPLY TO CONDITIONS THAT ARE SIMILAR TO THE CONDITIONS DESCRIBED IN THE SECTIONS/DETAILS, EVEN IF THEY ARE NOT SPECIFICALLY REFERENCED ON THE PLANS. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS SEQUENCES AND PROCEDURES OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO TEMPORARY SHORING AND BRACING, 6. DO NOT SCALE STRUCTURAL DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR, CONTACT THE ENGINEER. 7. CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF OSHA AND THE LOCAL GOVERNING CODES, CURRENT EDITION, AND ALL REQUIREMENTS SPECIFIED IN THE CODES SHALL BE ADHERED TO AS IF THEY WERE CALLED FOR OR SHOWN ON THE DRAWINGS. THIS SHALL NOT BE CONSTRUED TO MEAN THAT REQUIREMENTS SET FORTH ON THE DRAWING MAY BE MODIFIED BECAUSE THEY ARE MORE STRINGENT THAN THE CODE REQUIREMENTS OR BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED BY CODE. 8, THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS. ANY DEVIATIONS OR DISCREPANCIES ON THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER OF RECORD. BACK CHARGES WILL NOT BE ACCEPTED, REGARDLESS OF FAULT. WITHOUT PRIOR NOTIFICATION BY BUILDER WITHIN 48-HOURS AND INVESTIGATION BY FIELDSTONE. 9, THE TERMS'CONCRETE SCREW' AND'MASONRY SCREWSHALL BE USED INTERCHANGEABLY WITHIN THESE DRAWINGS. CONCRETE/MASONRY SCREWS AS GENERICALLY SPECIFIED WITHIN THESE DRAWINGS SHALL REFER TO ONE OF THE FOLLOWING ACCEPTED MANUFACTURER PRODUCTS: SIMPSON STRONG TIE TITEN TURBO, GENUINE TAPCON, OR HILTI KWIK-CON II. 10. CONTENT LINKED WITHIN OR CODES THAT MAY BE SHOWN WITH THE DRAWING SET ARE FOR INFORMATIONAL PURPOSES ONLY AND THE PROFESSIONAL SEAL ON THIS DRAWING DOES NOT APPLY TO CONTENT CONTAINED WITHIN ANY OR CODES. 11.POST INSTALLED EPDXY ANCHORAGE GENERICALLY NOTED WITHIN THESE DRAWINGS SHALL BE EITHER SIMPSON STRONG TIE SET-3G, OR HILTI HIT-HY-150 DESIGN CRITERIA: 1. BUILDING RISK CATEGORY =11 2. VERTICAL LOADING: ROOF TOP CHORD LIVE LOAD _=20 PSF (REDUCIBLE) ROOF TOP CHORD DEAD LOAD =7 PSF ROOF TOP CHORD DEAD LOAD (TILE) =15 PSF ROOF BOTTOM CHORD LIVE LOAD (w' STORAGE) -20 PSF ROOF BOTTOM CHORD LIVE LOAD (w/o STORAGE) =10 PSF ROOF BOTTOM CHORD DEAD LOAD--10 PSF FLOOR LIVE LOAD -40 PSF FLOOR LIVE LOAD (SLEEPING ROOMS) =30 PSF FLOOR DEAD LOAD =15 PSF DECK/BALCONY LIVE LOAD _-40 PSF NOTE TO TRUSS & I -JOIST MANUFACTURERS - ROOF & FLOOR SYSTEM DELEGATED DESIGN SHALL CONFORM TO THE FOLLOWING DESIGN STANDARDS: LOCATION TOTAL LOAD LIVE LOAD MAX TOTAL DEFLECTION ROOF TRUSSES L1240 L1240 1" FLOOR JOISTS/TRUSS L/360 L/480 1l2" NOTES: 1. MAXIMUM TOTAL LOAD DIFFERENTIAL DEFLECTION BETWEEN ADJACENT PARALLEL MEMBERS SHALL BE 5i8" 2. ANY MEMBER SUPPORTING BRICK/MASONRY SHALL BE LIMITED TO A TOTAL LOAD DEFLECTION OF L/600 3. FIELDSTONE AE CANNOT BE HELD RESPONSIBLE FOR ANY STRUCTURAL ISSUES RELATED TO ANY BUILDING COMPONENT IF COMPONENT SHOP DRAWINGS ARE NOT SUBMITTED TO PAC FOR REVIEW PRIOR TO FABRICATION. DELIVERY, OR INSTALLATION 3. LATERAL LOADING WIND CRITERIA: TORNADO WIND SPEED =N:A BASIC WIND SPEED__ =140 MPH EXPOSURE CATEGORY =C INTERNAL PRESSURE COEFFICIENT = +/- 0.18 (ENCLOSED) SEISMIC CRITERIA SITE CLASS =D SEISMIC DESIGN CATEGORY _ =A 4. EARTH PRESSURE LOADING: ALLOWABLE SOIL BEARING CAPACITY TOTAL LOADS (INCLUDING WIND & SEISMIC) -2000 PSF LATERAL EARTH EQUIVALENT FLUID PRESSURE WALLS UNBRACED AT TOP _=40 PCF WALL BRACED AT TOP =55 PCF 5. GUARDRAIL/HANDRAIL LOADING: ALL GUARDRAIL./HANDRAILS SHALL MEET 200 LBS (MINIMUM) CONCENTRATED FORCE APPLIED IN ANY DIRECTION. IN -FILL COMPONENTS OF GUARDRAIL SHALL MEET 50 PSF. THESE LOADS ARE TO BE EVALUATED INDEPENDENTLY AND ARE NOT TO ACT CONCURRENTLY WITH ANY OTHER LIVE LOAD. DEFLECTION OF GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICES (ICC-ES) AC 273 - "ACCEPTANCE CRITERIA FOR HANDRAILS AND GUARDS." CONCRETE NOTES: 1. STRUCTURAL CONCRETE HAS BEEN DESIGNED IN ACCORDANCE PER ACI 332 "RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". 2. CONCRETE PRODUCTION AND PLACEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI 332 "RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" EXCEPT AS MODIFIED BY STRUCTURAL REQUIREMENTS NOTED ON THE DRAWINGS. FOR P 3. CEMENT SHALL CONFORM TO ASTM C150 SPECIFICATION O ORTLAND CEMENT." CONCRETE SHALL BE NORMAL WEIGHT UNLESSINDICATED OTHERWISE. 4. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33 "SPECIFICATION FOR CONCRETE AGGREGATES." T 0. 5 REINFORCING SHALL CONFORMO ASTM A-615 GRADE 6 6. REINFORCEMENT SHALL BE FABRICATED AND ERECTED ACCORDING TO THE ACI STANDARDS: "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT", ACI 315 - AND "MANUAL OF ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES", ACI 315R. 7. REINFORCING STEEL AND WELDED WIRE FABRIC SHALL BE PLACED WITH MINIMUM CONCRETE COVER AND TOLERANCES AS FOLLOWS: SLAB -ON -GRADE: WITHIN UPPER 2/3 OF SLAB AND 3/4" MINIMUM COVER AT INTERIOR CONDITIONS; 1-1/2" MINIMUM COVER AT EXTERIOR CONDITIONS CONCRETE (FOUNDATION)AGAINST EARTH: 3" FORMED CONCRETE: 1-1/2" (#5 REBAR OR SMALLER) 2" (#6 REBAR OR LARGER) TOLERANCE: +/- 3/8" 8. REINFORCING STEEL SHALL NOT BE CUT. BENT OR STRAIGHTENED IN THE FIELD UNLESS APPROVED BY THE STRUCTURAL ENGINEER OR AS INDICATED ON THE DRAWINGS. 9. WELDING OF REINFORCING STEEL IS PROHIBITED UNLESS SPECIFICALLY DETAILED. WELDING WHERE DETAILED SHALL CONFORM TO AWS D1.4 SPECIFICATION. CONCRETE NOTES (CONTINUED): 10. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH AS FOLLOWS: FOUNDATIONS & FOUNDATION WALLS: 2500 PSI SLAB -ON -GRADE & CONCRETE BEAMS: 2500 PSI 11 CONTRACTOR SHALL TIE REINFORCING STEEL SECURELY IN PLACE PRIOR TO PLACING CONCRETE AND PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THEIR POSITION WITHIN SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. INSERTING DOWELS INTO WET CONCRETE IS NOT PERMITTED. ANCHOR RODS AND STEEL INSERTS SHALL BE SET BY TEMPLATE TO WITHIN A 1/8" TOLERANCE IN ANY DIRECTION WITH MINIMUM EMBEDMENT AND EXACT PROJECTION INDICATED ON THE DRAWINGS, PRIOR TO PLACING CONCRETE. 12. HOOKED BARS SHALL BE STANDARD 90 DEGREE HOOKS PER AGI UNLESS NOTED OTHERWISE ON THE DRAWINGS. MINIMUM LAP SPLICE SHALL BE CLASS B PER ACI 318. LOCATION OF LAP SPLICES SHALL BE AS INDICATED ON CONSTRUCTION DOCUMENTS. 13. DOWELS INTO FOUNDATION SHALL MATCH SIZE AND SPACING OF VERTICAL REINFORCEMENT AT ALL COLUMNS, PIERS AND WALLS, UNLESS OTHERWISE NOTED. 14. CONTRACTOR SHALL OBTAIN APPROVAL PRIOR TO PLACING OPENINGS OR SLEEVES NOT SHOWN ON THE DRAWINGS. THROUGH ANY STRUCTURAL MEMBER. 15. ONE OF THE FOLLOWING CONCRETE SLAB ON GRADE CRACK CONTROL METHODS SHALL BE USED (CONTRACTOR PREFERENCE): • CONTROL JOINTS: SHALL BE FORMED, SAWED, OR TOOLED TO A 1" MINIMUM DEPTH WITHIN 24 HOURS OF CONCRETE PLACEMENT. MAXIMUM JOINT SPACING FOR UNREINFORCED SLAB IS AS FOLLOWS: 3-1/2' SLAB: 8 FEET O.C. EACH DIRECTION 4" SLAB: 10 FEET O.C. EACH DIRECTION • WELDED WIRE FABRIC (W.W.F.) 6X6-W1 4XW1 4. WELDED WIRE FABRIC SHALL BE FURNISHED IN FLAT SHEETS (ROLLS NOT PERMITTED) AND SHALL CONFORM TO ASTM A-1064 AND HAVE A MINIMUM SIDE AND END LAP OF 8 INCHES. • MICRO- OR MACRO- SYNTHETIC FIBER REINFORCEMENT FIBER LENGTHS SHALL BE 1,12' TO 2-1/4' IN LENGTH. DOSAGE AMOUNT SHALL BE FROM 3/4 TO 3.0 POUNDS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER/SUPPLIER SHALL PROVIDE CERTIFICATION OF COMPLIANCE WITH ASTM C1116 WHEN REQUESTED BY THE BUILDING OFFICIAL. 16. CONTROL JOINTS SHALL BE FURNISHED WITH A FULL-LENGTH KEYWAY CENTERED ON MEMBERS. WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY SHALL BE 25 % OF THE CROSS-SECTION DIMENSION OF THE MEMBER AND MINIMUM 1-112 INCHES INTO THE FIRST POUR OF CONCRETE_ 17. PROVIDE POCKETS OR RECESSES IN CONCRETE WORK FOR COLUMNS AND BEAMS AS REQUIRED EVEN IF NOT SHOWN ON THE DRAWINGS. PROVIDE CONCRETE FILL AFTER BEAM ERECTION. 18. CURING OF CONCRETE SURFACES SHALL CONFORM TO ACI 308.1 "STANDARD SPECIFICATION FOR CONCRETE CURING" AND ACI 308R "GUIDE TO CURING CONCRETE FOUNDATION NOTES: 1. CONTRACTOR SHALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES AND FIELD MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE. 2. TOP OF SPREAD FOOTING ELEVATIONS NOTED ON PLAN ARE MINIMUM ELEVATIONS. IN ALL CASES FOOTINGS ARE TO BEAR ON UNDISTURBED NATURAL SOILS OR ENGINEERED FILL HAVING A MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2000 PSF. 3. SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING. FOUNDATIONS POURED AGAINST THE EARTH REQUIRED THE FOLLOWING PRECAUTIONS: SLOPE SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING BEFORE AND DURING CONCRETE PLACEMENT. PROVIDE POLYETHYLENE VAPOR RETARDER COMPLYING WITH GOVERNING BUILDING CODE LISTED ON THIS SHEET AGAINST SOILS WHERE CONCRETE IS TO BE PLACED: LAP ALL EDGES 6 INCH (MINIMUM) AND SEAL WITH ADHESIVE. 4. WHERE FOOTING STEPS ARE NECESSARY, THEY SHALL BE NO STEEPER THAN ONE VERTICAL TO TWO HORIZONTAL U.N.O. S. FOOTINGS SHALL BE CENTERED UNDER COLUMNS AND WALLS UNLESS SPECIFICALLY DETAILED OTHERWISE ON THE DRAWINGS. 6. NO FOOTINGS OR SLABS SHALL BE PLACED ON OR AGAINST SUB -GRADE CONTAINING FREE WATER, FROST OR ICE. SHOULD WATER OR FROST, HOWEVER SLIGHT, ENTER A FOOTING EXCAVATION AFTER SUB -GRADE APPROVAL, THE SUB -GRADE SHALL BE REINSPECTED BY THE GEOTECHNICAL ENGINEER/ TESTING LABORATORY AFTER REMOVAL OF WATER OR FROST. 7. CONTRACTOR SHALL FURNISH ALL REQUIRED DE -WATERING EQUIPMENT TO MAINTAIN A DRY EXCAVATION UNTIL BACKFILL IS COMPLETE. 8. A GEOTECHNICAL ENGINEER REGISTERED IN THE STATE OF WORK PERFORMED SHALL INSPECT THE CONDITION AND ASSURE THE ADEQUACY OF ALL SITE PREPARATION, SUBGRADES, FILLS, BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS AND WALLS. HE SHALL SUBMIT REPORT TO THE ARCHITECT/ENGINEER DESCRIBING HIS INVESTIGATIONS OF ANY NON -CONFORMING WORK. BACKFILLING: 1. DO NOT PLACE BACKFILL AGAINST FOUNDATION WALLS - DESIGNED AS SUPPORTED AT TOP AND BOTTOM - UNTIL BASEMENT LEVEL AND FIRST FLOOR SYSTEM ARE IN PLACE. SHORE AND/OR BRACE WALLS AS REQUIRED IF BACKFILLING OPERATIONS ARE TO BE CARRIED OUT PRIOR TO PLACEMENT OF FLOOR SYSTEM. 2. WHERE BACKFILL IS TO BE PLACED ON BOTH SIDES OF FOUNDATION WALLS, PROVIDE A BALANCED BACKFILL AGAINST FOUNDATION WALLS TO ELIMINATE LATERAL LOAD EFFECTS, OR PROVIDE NECESSARY TEMPORARY LATERAL SUPPORT TO THE TOP OF THE WALL UNTIL PERMANENT SUPPORT IS INSTALLED. 3. BACKFILL MATERIAL SHALL CONSIST OF CLEAN, WELL GRADE GRANULAR SOILS, FREE OF ORGANIC MATERIAL AND BE COMPACTED TO 95 % OF MAXIMUM DENSITY, AS DETERMINED BY THE MODIFIED PROCTOR METHOD (ASTM D1557), IN LIFTS NOT EXCEEDING 8INCHES. MASONRY NOTES: 1 _ CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530, "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 530.1, 'SPECIFICATIONS FOR MASONRY STRUCTURES." 2. CONCRETE MASONRY SHALL CONFORM TO ASTM C90 AND HAVE A MINIMUM COMPRESSIVE STRENGTH Pm = 1,500 PSI U.O.N. MASONRY SHALL HAVE A TEXTURE SUITABLE FOR STUCCO APPLICATIONS WHERE ARCHITECTURAL DRAWINGS INDICATE STUCCO APPLICATION. 3. CONCRETE MASONRY UNITS SHALL BE LAID IN RUNNING BOND. 4. MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270 WITH MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. MORTAR BELOW GRADE SHALL BE TYPE M. ELSEWHERE MORTAR MAY BE EITHER TYPE M OR S UNLESS SPECIFICALLY INDICATED OTHERWISE. USE EITHER PORTLAND CEMENT/LIME OR MASONRY CEMENT FOR MORTAR. S. GROUT SHALL CONFORM TO ASTM C476 WITH MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2,500 PSI. 6. STEEL BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60. 7_ VERTICAL CELLS CONTAINING REINFORCING AND GROUT SHALL FORM A CONTINUOUS CAVITY, FREE OF MORTAR DROPPINGS. 8. VERTICAL CMU WALL REINFORCING SHALL BE AS NOTED ON THE DRAWINGS. DOWELS TO CONCRETE FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL REINFORCING UNLESS NOTED OTHERWISE. REINFORCE CMU CORE AT CORNERS, EACH SIDE OF CONTROL JOINTS AND EACH SIDE OF WALL OPENINGS WITH (U-#5 CONTINUOUS VERTICAL REINFORCING BARS.. 9. HORIZONTAL BOND BEAM AND VERTICAL REINFORCING SHALL BE CONTINUOUS U.O.N. LAP SPLICE REINFORCING PER THE SCHEDULE OR USE MECHANICAL SPLICES ADEQUATE FOR 125% OF SPECIFIED YIELD STRENGTH OF THE BAR. LAP VERTICAL REINFORCEMENT WITH MINIMUM DOWELS OF SAME SIZE AND SPACING THAT HAVE BEEN PREVIOUSLY INSTALLED IN THE FOUNDATIONS. DOWEL EMBEDMENT IN CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE CONCRETE NOTES. BAR SIZE LAP SPLICE LENGTH BEND DIAMETER ACI HOOK #4 20' 3" 1 10" #5 25' 3-3/4" 10" 116 34' 4-1/2" 11" MASONRY NOTES (CONTINUED): 10. REINFORCING BARS SHALL BE HELD IN POSITION BY WIRE TIES OR OTHER APPROVED MEANS TO ENSURE DESIGN LOCATION AND LAP. PLACE BARS AND LAP PRIOR TO GROUTING. 11. GROUTING OF MASONRY WALLS SHALL CONFORM TO RECOMMENDED PROCEDURE FOR "LOW LIFT GROUTING" OR "HIGH LIFT GROUTINGAS OUTLINED IN THE NCMA-TEK 3-2A -GROUTING FOR CONCRETE MASONRY WALLS AND ACI 530/ASCE 5 SPECIFICATION FOR MASONRY STRUCTURES. GROUT LIFTS SHALL NOT EXCEED 5 FEET WITHOUT MECHANICALLY CONSOLIDATED (VIBRATED) GROUT POURS. 12. LIFTS OF GROUT SHALL BE KEYED 41NCHES INTO THE PREVIOUS COURSE OF MASONRY BELOW. 13. MASONRY BELOW GRADE SHALL BE GROUTED SOLID. 14. CONTRACTOR SHALL BRACE MASONRY WALLS TO RESIST WIND LOADS UNTIL FLOORS AND ROOFS ARE IN PLACE, AND THE MASONRY HAS REACHED 75% OF THE REQUIRED STRENGTH FM. BRACING SHALL BE PROVIDED IN ACCORDANCE WITH OSHA - CONSTRUCTION SAFETY STANDARDS FOR MASONRY WALL BRACING AND NCMA TEK 3-46 - "BRACING CONCRETE MASONRY WALLS DURING CONSTRUCTION." WOOD FRAMING NOTES: 1. STRUCTURAL SAWN LUMBER, STRUCTURAL COMPOSITE LUMBER, AND CONNECTIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE 'NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION." INDS) 2. PLYWOOD HAS BEEN DESIGNED IN ACCORDANCE WITH "PANEL DESIGN SPECIFICATION." AND SHALL CONFORM TO "VOLUNTARY PRODUCT STANDARD PSI CONSTRUCTION AND INDUSTRIAL PLYWOOD." 3. ORIENTED STRAND BOARD (OSB) SHALL CONFORM TO "VOLUNTARY PRODUCT STANDARD PS2 PERFORMANCE STANDARD FOR WOOD -BASED STRUCTURAL -USE PANELS'. 4. ALL BEAMS AND HEADERS SHALL BE (2)-PLY U.N.O. 5, WOOD SILL PLATES AND WOOD WALLS SUPPORTED ON CONTINUOUS CONCRETE OR MASONRY SHALL BE ANCHORED WITH 1/2' DIAMETER CAST -IN -PLACE ANCHOR BOLTS WITH 7" EMBEDMENT, 4' (MINIMUM) AND 12" (MAXIMUM) FROM END OF SILL PLATE(S), LOCATED WITHIN THE MIDDLE THIRD OF THE SILL PLATE. WITH NUT AND 3`x3'x0.229" WASHERS AT THE ANCHOR SPACING BELOW MAXIMUM ANCHOR BOLT SPACING = 2'-0" O.C. REFER TO "PRE -APPROVED FIELD REPAIR NOTES" SECTION FOR ALTERNATE ANCHORAGE APPROVALS. FOR OTHER ANCHORS NOT LISTED, SUBMIT TO ENGINEER OR RECORD FOR REVIEW. 6. ALL LUMBER IN CONTACT WITH EARTH, CONCRETE, OR MASONRY - AND WOOD BEAMS POCKETING INTO CONCRETE OR MASONRY WALLS HAVING CLEARANCES LESS THAN 112' ON TOP, SIDES, AND END(S) SHALL BE PRESSURE TREATED OR SEPARATED WITH AN IMPERVIOUS MOISTURE BARRIER. 7. STRUCTURAL SAWN LUMBER SHALL BE SPRUCE -PINE -FIR NO.1 /NO.2 OR BETTER U.N.O. WITH BASE DESIGN VALUES: Fa= 875 PSI F� = 425 PSI FT = 450 PSI F,= 1150 PSI Fv= 135 PSI E= 1400 KSI WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. 8. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED WITH DOUBLE (2X) TOP PLATES INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS. END JOINTS IN DOUBLE (2X) TOP PLATES SHALL BE OFFSET AT LEAST 24 INCHES AND SHALL BE NAILED WITH NOT LESS THAN (8)-0.162"x2-1/2" FACE NAILS ON EACH SIDE THE JOINT_ DOUBLE (2X) TOP PLATES OF EXTERIOR WALLS AND INTERIOR LOAD BEARING WALLS SHOWN ON DRAWINGS SHALL BE SOUTHERN YELLOW PINE NO OR BETTER WITH BASE DESIGN VALUES: Fg- 1100 PSI F� = 565 PSI F, 675 PSI F,= 1450 PSI F,= 175 PSI E= 1400 KSI WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. 9. STRUCTURAL COMPOSITE LUMBER SHALL CONFORM TO ASTM D 5456 WITH THE FOLLOWING ALLOWABLE DESIGN STRESSES MICROLLAM LVL PARALLAM PSL TIMBERSTRAND LSL E = 2000 KSI E = 1800 KSI E = 1300 KSI Fa = 2600 PSI Fe = 2400 PSI F, = 1700 PSI (*) -'BOOZER BEAM 2.1 E' ARE AN ACCEPTED ALTERNATE TO PSL COLUMNS SPECIFIED ON PLANS PROVIDED THE'BOOZER BEAM 2.1 F IS OF EQUAL OR GREATER SECTION DIMENSION TO THE PSL COLUMN AND OF EQUAL OR LESSER HEIGHT 10.FLOOR SHEATHING SHALL BE 23/32 INCH, APA RATED SHEATHING, 48/24 MIN., EXPOSURE 1. INSTALL WITH THE LONG DIMENSION OR STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. PANEL EDGES SHALL BE TONGUE -AND -GROOVE. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO SUPPORTING MEMBERS. ADHESIVE SHALL MEET APA SPECIFICATION AFG.01, APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. PROVIDE 0.131 "x2-1/2" COMMON NAILS AT6 INCH O.0 ALONG SUPPORTED PANEL EDGES AND 12 INCH O.G AT INTERMEDIATE SUPPORTS. 11. FOR INTERIOR WALL HEADERS PROVIDE (1)-2X JACK STUD AND (1)-2X KING STUD U.N.O. ON DRAWINGS. 12.FOR EXTERIOR WALL HEADERS PROVIDE (1)-2x JACK STUD AND (1)-2x KING STUD, MINIMUM, REFER TO CHART BELOW U.N.O ON DRAWINGS: WINDSPEED OF <= 140 EXP. C WALL HEIGHT SET 9FT 10FT STUD SIZE HEADER SPAN (FF) 4 1J/1K 1J/1K 1JI1K 6 1J/1K 1J/1K 1J/2K 8 1J/1K 1J/2K 1J/3K 10 1J/2K 1J/2K 1J/4K 2x4 12 1J/2K 1J/3K 1J/4K 14 1J/2K 1J14K ENG 16 1J13K 1J/4K END 18 1J/3K ENG ENG WINDSPEED OF = 140 EXP. C WALL HEIGHT 8FT 9FT 10FT STUD SIZE HEADER SPAN (FT) 4 1Ji1K 1J/1K 1J/1K 6 1J/1K 1J/1K 1J/1K 8 1J/1K 1J/1K 1J/1K 10 1J/1K 1J/1K 1J/1K 2x6 12 1J/1K 1J/1K 1J/1K 14 1J/1K 1J/1K 1J/1K 16 1J/1K 1J/1K 1J/1K 18 1J/iK 1J/1K 1J/1K 13. WALLS SHOWN ON THE FRAMING PLANS ARE LOAD BEARING WALLS; WALLS NOT SHOWN ON STRUCTURAL FRAMING PLANS ARE INTERIOR NON -LOADING BEARING PARTITION WALLS. 14. LOAD BEARING WALLS SHALL BE CONSTRUCTED WITH 2X STUDS AT 16" O.C. MAXIMUM U.N.O. NON -LOAD BEARING PARTITION WALLS SHALL BE CONSTRUCTED WITH 2X OR METAL STUDS (18 GA. MIN.) @ 24" O.C. MAXIMUM. 15. STUD COLUMNS UNDER LOAD BEARING POINTS OF GIRDERS/BEAMS SHALL MATCH THE GIRDER/BEAM PLY COUNT WITHIN 1/2` TOLERANCE (2-PLY STUD COLUMN MINIMUM). SOLID BLOCK ALL GIRDER/BEAMS THIRD FLOOR SYSTEMS AND TO THE FOUNDATION. 16. WHEN NOT SHOWN ON DRAWINGS OR DETAILS. THE NAILING SCHEDULE FOR WOOD FRAMING ELEMENTS SHALL COMPLY WITH THE IRO TABLE R602.3(1). 17. FLOOR SYSTEMS ARE DESIGNED BY THE TRUSS AND/OR WOOD I- JOIST MANUFACTURER'S DELEGATED ENGINEER AND BE IN CONFORMANCE WITH THE LOADS & DEFLECTIONS IDENTIFIED IN THE DESIGN CRITERIA NOTES SECTION. INSTALL PER MANUFACTURER'S RECOMMENDATIONS, NOTES, AND DETAILS. FLOOR FRAMING CONCEPT LAYOUTS SHOWN WITHIN THE DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY TO DEPICT FLOOR SYSTEM -TO -WALL CONNECTIONS. CHANGES TO THE CONCEPTUAL FLOOR LAYOUT SHOWN IS NOT PERMITTED WITHOUT A LETTER AND REVIEW FROM THE ENGINEER OF RECORD. PREFABRICATED WOOD I -JOIST SHALL CONFORM TO ASTM D 5055. JURISDICTION SPECIFIC NOTES: 1. FOR PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO LANAIS, PORCHES, AND BALCONIES A 1/2" (MINIMUM) EXTERIOR GRADE SOFFIT BOARD WITH A CEMENTITIOUS KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE REQUIREMENTS OF ASTM C932 TO GIVE THE CEILING WATER RESISTANCE. THE SOFFIT BOARD PRODUCT SHALL BE ATTACHED PER MANUFACTURER SPECIFICATIONS TO BE IN COMPLIANCE WITH R703.1. 2_ THE SOFFIT DESIGN PRESSURE IS AS NOTED IN THESE DOCUMENTS. WITH KAYCAN VINYL SOFFIT INSTALLED IN ACCORDANCE WITH MANUFACTURER'S REQUIRMENTS AND ICC-ES EVALUATION REPORT ESR-1495 THE SOFFIT WILL COMPLY WITH R703.1. PRE-ENGINEERED ROOF TRUSS NOTES: 1. ROOF TRUSS SHOWN ON STRUCTURAL DRAWINGS IN CONCEPTUAL ONLY TO ILLUSTRATE TRUSS -TO WALL CONNECTIONS AND DOES NOT SERVE AS A ROOF TRUSS DESIGN. ROOF TRUSSES SHALL BE DESIGNED AND MANUFACTURED IN CONFORMANCE FOR THE INDICATED LOADS WITH ANSI/TPI 1 'NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION." FINAL PRE-ENGINEERED ROOF TRUSS FRAMING LAYOUT AND DESIGNS TO BE BY ROOF MANUFACTURER'S DELEGATED ENGINEER. 2. ROOF TRUSSES SHALL BE DESIGNED FOR THE SUPERIMPOSED LOADS IDENTIFIED IN THE DESIGN CRITERIA NOTES SECTION. 3. THIS PLAN IS DEVELOPED FROM THE REVIEW OF MASTER TRUSS FILES. ANY LOT THAT DEVIATES FROM THE MASTER TRUSS FILE ON REOORD,OR FOR PLANS FIELDSTONE AE IS NOT CONTRACTED TO PERFORM TRUSS REVIEW ON, THE CONTRACTOR IS RESPONSIBLE TO ASSURE THE DIRECT COMPLIANCE OF TRUSS MANUFACTURER LAYOUT TO THESE DRAWINGS & VERIFY ALL TRUSS CONNECTORS ARE SUFFICIENT TO WITHSTAND THE UPLIFT/LATERAL LOADS IMPOSED 4. TRUSS MANUFACTURER SHALL PROVIDE HANGERS AND CONNECTIONS ADEQUATE FOR LOADS AT ALL TRUSS -TO -TRUSS, TRUSS -TO -BEAM, AND BEAM -TO -TRUSS CONNECTIONS. 5. REFER TO ARCHITECTURAL DRAWINGS FOR TRUSS SHAPE, OVERHANG, DIMENSIONS, SLOPES, SPANS, DRAINAGE, BEARING WALL HEIGHTS, ETC. 6. THE POSITIONS, WEIGHTS, AND METHODS OF ATTACHMENTS OF ALL MECHANICAL UNITS, ELECTRICAL FIXTURES, PLUMBING, FIRE SPRINKLERS, ETC SHALL BE INCLUDED IN THE DESIGN OF THE TRUSSES BY THE TRUSS MANUFACTURER. SEE ARCHITECTURAL DRAWINGS FOR ATTIC ACCESS SIZE AND LOCATIONS. 7. SUPERIMPOSED LOADS FROM SECONDARY FRAMING (I.E. SOFFITS. PARAPETS, VALLEY FRAMING, UPPER TRUSSES, ETC) SHALL BE INCLUDED IN THE DESIGN OF SUPPORTING TRUSSES. 8. CONTRACTOR TO PROVIDE TRUSS BRACING PER BCSI-B3 IN ADDITION TO PERMANENT BRACING SHOWN ON THE TRUSS DESIGN PROVIDED BY THE DELEGATED TRUSS ENGINEER. PRE -APPROVED FIELD REPAIR NOTES: 1. MISPLACED DOWEL REPAIR: THIS NOTE DESCRIBES ALTERNATES TO MITIGATE THE CASTING OF REBAR VERTICAL REINFORCEMENT AT AN INCORRECT LOCATION. IF THE WALL HAS NOT BEEN BUILT: DRILL AND EPDXY #5 REBAR (36" LG.) INTO THE THICKENED EDGE OF SLAB AT THE CORRECT LOCATION. AS WALL IN CONSTRUCTED, LAP REBAR IN ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12' LAP AT THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAM/BOND BEAM. COMPLETE GROUTING OF WALL. IF THE WALL HAS ALREADY BEEN BUILT: PRIOR TO GROUT PLACEMENT, OPEN THE WALL AT THE CORRECT LOCATION APPROXIMATELY 16' (H) x 4" (W) AT FLOOR LEVEL. DRILL AND EPDXY #5 REBAR (32' LG.) INTO THE THICKENED EDGE OF SLAB. LAP VERTICAL REINFORCEMENT IN ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12" LAP AT THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAM/BOND BEAM. COMPLETE GROUTING OF WALL. 2. MISSINGWISPLACED ANCHOR BOLT: ALTERNATE SILL PLATE ANCHORAGE SOLUTIONS INTO CONCRETE: A 1/2"x6" TITEN HD WITH 1-3/4- MINIMUM EDGE DISTANCE AND 6" MINIMUM END DISTANCE IS A DIRECT 1 1 REPLACEMENT FOR A 1/2" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT INTO CONCRETE. A 1/2" THREADED ROD SET-3G EPDXY 7" EMBEDMENT WITH 1-3/4 MINIMUM EDGE DISTANCE AND 7-1/2" MINIMUM END DISTANCE IS A DIRECT 1:1 REPLACEMENT FOR A 1/2" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT INTO CONCRETE. INTO GROUT FILLED MASONRY (GFCMU): A 1/2"x6" TITEN HD WITH 1-3/4" MINIMUM EDGE DISTANCE AND 8' MINIMUM END DISTANCE AT 4'-8" O.C. REPLACES A 1/2" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT AT 6-0" O.C.; LIKEWISE A 1/2"x6" TITEN HD WITH 1-3/4" MINIMUM EDGE DISTANCE AND 8" MINIMUM END DISTANCE AT 2'-8" O.C. REPLACES A 1/2" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT AT 4'-0' O.C.. 3. SIMPSON MASA SILL ANCHORS MAYBE USED AS AN ALTERNATE TO THE ANCHOR BOLTS AND SPACING NOTED HERE -IN ACCORDING TO THE FOLLOWING TABLE: BASIC WIND SPEED (MPH) MAXIMUM SPACING <140 6-0" 140 V-6" 150 V-3" NOTES: 1. MASA SPACING BASED ON NO MORE THAN ONE IN THREE INSTALLED WITH ONE LEG INSTALLED VERTICALLY ATTACHED TO STUD 4. MISSING/MISPLACED TRUSS STRAP ANCHOR: REFER TO 'MISSED TRUSS STRAP REPAIR" DETAIL WITHIN DRAWINGS. FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/8' BUT LESS THAN 1-1/2" FROM THE FACE OF THE TRUSS, A SHIM SHALL BE PROVIDED AND NAIL LENGTH INCREASED TO PENETRATE THROUGH BOTH PLYS OF MATERIAL (LE. 3" LG. NAILS). WHEN GAP IS GREATER THAN 1-1/2', INSTALL NEW ANCHORS. 5. MASONRY WALL OVERHANGING SLAB BLOCK OVERHANG REPAIR < 5/8' NO REPAIR REQ'D 5/8` < OVERHANG < 1-1/2" GROUT SOLID BOTTOM 3 COURSES OF AFFECTED WALL LENGTH > 1-112' CONTACT ENGINEER OF RECORD FOR REPAIR 6. NOTCHED TOP PLATES & STUDS REQUIRING REPAIR AT STUDS: STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH GREATER THAN 25%OF THE WIDTH IN BEARING WALLS, OR 40% IN NON -LOAD BEARING WALLS; OR WHEN A HOLE IS DRILLED/BORED TO A DIAMETER EXCEEDING 40% OF THE STUD WIDTH IN BEARING WALLS, OR 60% OF THE STUD WIDTH IN NON -BEARING WALLS. IF THE MAXIMUM HOLE/NOTCH SPECIFICATIONS ARE EXCEEDED THEN A STUD SHOE MUST BE INSTALLED. STUD SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE HSS2-SDS1.5 WITH (12)T/4"X1-1/2" SDS SCREWS. FOR MULTI -PLY 2X STUDS USE HSS2-"#"-SDS3 WITH IT 2)-1/4"X3" SDS SCREWS, WHERE `#" CORRESPONDS TO THE NUMBER OF STUDS IN THE MULTI -PLY. AT TOP PLATES: A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 50%OF THE PLATE WIDTH IS REMOVED FOR PIPING (EXCEPT WHEN THE SIDE OF THE WALL WITH THE NOTCH OR CUT IS COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT THROUGH. THE REQUIRED REPAIR IS A GALVANIZED 16-GAUGE METAL TIE THAT IS AT LEAST 1-1 /2` WIDE AND MUST BE FASTENED WITH (8)-16D NAILS ON EACH SIDE OF THE OPENING. 02O \`\xXA11111111,'/// 0 Fieldstone 30,N! ry CO .A.# ARCHITECURE: \ AA26002802� C.O.E.# ENGINEERING: � � No. _ 29349 O IBRAHEM ELAYEB, PE P.E.# 91476 ■ BENJAMIN NIESE, PE : O STATE OF lV� P.E.# 86025 ;� ' !C4ORID� •?� 10/25/2024 /sS'ONA` DATE ,�1111111110 Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 + 1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae.com O O Y J m L0 _ Z N f- O J O Q > W Ln Z o J Q � W S z U) W F LU J 0 o� Q LL J CC U W Q a } _ o� w 0 2 Vcc oo LLI co N F- DRAWN BY: FAE VERSION: 5.0 SHEET NAME COVER SHEET SHEET # .1-14 SO0 CMU COL CMU COL 8' CMU, VERT -�\ PER PLANL� PER PLAN REINS RE' 9" STARTER VERT. REINF. _ VERT. REINF COURSE Q, ♦ PER PLAN PAVERS PER PLAN 0-0" ALT. CMU SEAT Y� SLOPE 0-0" `, SLOPE AJ -- @ 1 1/2" FROM TOP OF SLAB z z w mI o z CONCRETE CONCRETE of wo < -� o wo FINISH GRADE FOOTING - m FOOTING w G PER PLANy '-I c7 PER PLAN - m �MONOLITHIC END PER PLAN - I, PER PLAN- 1,4 @ . w/ ^ 2 STORY (2)-#4 CONT. ON CHAIRS CONCRETE PAVERS -; EXTERIOR AOWALLG „/0,/2023 eMik RY CORNER COLUMN FO FMM-010 8'CMU. VERT.- - 8"CMU. VERT. REINF. PER PLAN REINF PER PLAN PA POURED CURB OR CMU BLOCK, 9" CMU STARTER COURSE it ��� L -� \+� FINISH GRADE ,� 0 r� POURED CURB OR CMU BLOCK 1 FINISH GRADE roz oz 1 JI.- MONOLITHIC FND. w/ (2) MONOLITHIC FND- w/ (2) '' 1',4 #4 CONT ON CHAIRS CONT. ON CHAIRS 2 STORY 2 STORY Foa IYERIORMASONRYWALL @GARAGE 11/01/2023 FMM-040 DOOR PER SPEC. zl a DOOR THRESHOLD NJ / I _ SL.PE FIT .a: 141E BM _@ CONCRETE 2 STORY EXTERIOR DOOR SILLS 3/4" RED Q�F CMU COL. PER PLAN VER FINISH GRADE - PER PLANNE CONCRETE z FOOTING �. oo 0 PER PLAN f m 'T PER PLAN_-_ 2/28/2022 FGM-033 8" CMU, VERT. REINF. PER PLAN POURED CURB OR CMU BLOCK MONOLITHIC FIND. w/ (2) #4 PONT. ON CHAIRS SCREENEDIN SCREENED IN SYSTEM PER MANUF. SYSTEM PER MANUF (1) #4 CONT. ON CHAIRS** SLOPE'' PAVERS PER SPEC. FINISH GRADE FINISH / SLOPE GRADE FILL CONG. SLAB -fie- PER PLAN COMPACTED CONT PAVERS (I GRADE BEAM @ SCREENED ENCLOSURES ONLY THICIQ:NED SLAB._ GREENED ENCLOSURES ONLY "#6 ALLOWED ILO#4 SLAB EDGE @ SCREENED IN ENCLOSURES 11012023 SF11 B' CMU. VERT. FMG-113 REINF. PER PLAT• 1 10 1/2' 4 POURED CURB OR 0'-0' SLOPS CMU BLOCK SLOPE 3/4" RECESS IN SLAB J ice" '� MONOLITHIC FND. w/ (2) @ #4 CONT. ON CHAIRS RECESS w/SLAB 2STORY RECESS w/PAVERS2STORY SGARAGE DOOR RECESSED SILL 11/01/2023 FMM-0 5 DOOR PER SPEC. - DOOR THRESHOLD 3 w w aj -}� a r PAVERS PER SPEC 0-0 SLOPE (THICKNESS VARIES) ALT. BRICK THRESHOLD �II�I z 10• } PAVERS� 2 STORY ALT. FLUSH BRICK THRESHOLD SGD PER SPEC. PAVERS PER SPEC. GROUT BED (THICKNESS VARIES) 0-0, .� // SLOPE III—IIr I IT . 1 SLIDING GLASS DOOR 2 STORY 2/28/2022 FMG-070 WALL & FTG 2x FRAME WALL w/ P.T. - ANCHOR BOLTS OR STRAPS. SILL PLATE, PER PLAN / SEE GENERAL NOTES, U.N.O. STEP PER PLAN SLOPE J,H 1 1 1 4 (2)-#4 CONT. ON CHAIRS (3L#4 AT 2 STORY** 2 STORY **#5 ALLOWED ILO #4 r1THICKENED SLAB @ GARAGE (BEARING) 0,/2023 0J FMG-090 PER PLAN. WALL 8 FTG EXPANSION POST BASE CONNECTOR SCHEDULE ALTERNATE TO Pk CORNER BAR w/ LAP ANCHOR 4' MIN BASIC WIND SPEED CORNER SPLICE: " POST PER PLAN SPLICE EA. SIDE. SAME ANCHOR BOLTS OR STRAPS, - 2x FRAME WALL w/ P.T. EPDXY ANCHOR: PER GEN NOTES � PROVIDE CONT STEEL '. � /' SEE GENERAL NOTES, U.N.O. SILL PLATE, PER PLAN 1 3/q" MIN POST BASE, S1ZE PER POST SIZE AS CONT. FrG. STEEL REINF. BARS BENT AT ,{ CONC SLAB PER PLAN CHART U.N.O. PER PLAN SIZE=140 MPH > 140 MPH CORNERS TO COMPLY , It FINISH GRADE - - SLOPE - 4x4 ABW447 ABU44Z JI w/THE INTENT OF THE -- GONG. SLAB ,4 PER PLAN 6x6 ABW66Z ABU66Z BUILDING CODE J �� NUMBER OF CORNER REFER TO DETAIL FOR MINIMUM EDGE DISTANCES IN BARS EQUALS NUMBER �I 1L '• J1 �w z ANCHOR TYPE SELECTION �'°•-� OF CONT BARS 'l oU wo STD. SLAB BEYOND TYPE'ABWPOST BASES USE, 2 X3 3/4" EXPANSION �- (2) #4 CONT a Z FTG &REINF ANCHOR OR 1/2" ATR DRILL & EPDXY W/ 3" MIN EMBED NUMBER OF ON CHAIRS" LL PER PLAN TYPE 'ABU' POST BASES USE 1/2 XS 1/2" EXPANSION VERTICAL a LAP SPLICE REBAR PER PLAN POSTIFTG LOCATION DOWEL AS **#5 ALLOWED ILO #4 ANCHOR OR Sl8" ATR DRILL &EPDXY Wi 8" MIN EMBED REO'D IN PLAN PER PLAN **#5 ALLOWED ILO #4 Fi _,)THICKENED SLAB @ INT. WALL (BEARING) 6, /2023 efiOSTFG @ PORCFV" „,.1,2023 SRE�IIIIFORCEMW @ FTG. CORNERS 11/01/2023 FMG 100 FMG110 FGG120 8" CMU. VERT. REINF. PER PLAN CONSB EXTERIOR FINISH (PER ELEV.(1) #4 ) SEE FOUNDATION PLAN 9 1/4' BAR CORCMENT BAR CONT.. TVP. i SEE FOUNDATION PLAN FORM SLAB PERC PLAN zN PENETRATING FINISH FLOOR g RECESS w/ 2.10 @ FINISH GRADE PIPE \ PENETRATING PIPE*+ .� _ _ _ _ _ _ _ - - LOOP TIE AS SHOWER LOCATION .� REQUIRED. 00" - w TO 0_ h 0,_0„ V +• g PVC SLEEVE" ;i PVC LONGITUDINAL 4 TRANSVERSE.: MONOLITHIC SLEEVE - SIDE aI FRONT VB1A/ MONOLITHIC DE VIEW ONT -. END. PER PLAN "VERIFY LOCATION IN FIELD FND. PER PLAN 8"BEMINWI PENETRATION- CMU 11/12/2021 SRRE�CESS IN SLAB @ SHOWER2/28/2022 -Y FMM�260 8" CMU, VERT. REINF. PER PLAN 8" CMU, VERT- REINF. _ 8" CMU, VERT. FINISH GRADE PER PLAN 0'- " SLOPE REINF. PER PLAN 0 SLOPE -FINISH GRADE �r FINISH I� oi0 w PAVERS OR SLAB GRADE o �.,,� om p PER SPEC Z- ,�. CJ CONCRETE CONCRETE S m CONCRETE FOOTING FOOTING FOOTING PER PLAN PER�LANj, PER PLAN PER PLAN PER PLAN �, PER PLAN Fo36 MASONRY COL ON SPREAD FTG. — 2,28/2022 NOT TO SCALE FGM­032 WALL 3/16"x 3-3/4" CONCRETE & FTG 2x FRAME WALL w/ P.T. SCREWS @ 16" O.C. r SILL PLATE. PER PLAN - (1)-#4CONT - STEP PER PLAN \ ON CHAIRS U.N.O.- IT oI, 7 '�- CONC SLAB PER PLAN **#5 ALLOWED ILO #4 THIIENED SLAB @ GAGE (NON BEANG) 11/01/2023 Fos NOTOSLCAE FMG-080 ORO Fieldstone \\`` \ .pMIN / //i/ C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERING: No. 29349 O IBRAHEM ELAYEB, PE .� P.E.# 91476 lV� ■ BENJAMIN NIESE, PE %�O STATE OF �� P.E.# 86025 i�� !�LORIDp'. ��� 10/25/2024 01YA` DATE IIIII Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 + 1 248.622.4035 Florida 12906 Tampa Oaks Blvd - Suite 150 Tampa, FL 33637 + 1 813.466,3310 www. fief dstonea e- com 0 Y J m L0 _ Z V O J O < j LU M, zM Q Q LU J ED R Z U) UI W _ ~ LILT J J cc: Q Q L J O m U W a ¢ } �_ C()_ oBE :� cc W rn S V 0 co N H O F_ L_ DRAWN BY: I FAE VERSION: 5.0 SHEET NAME FOUNDATION DETAILS SHEET # S 1.0 r 2'-83/4' 3'-1P 3'-10, 6-014 3'-10' 3--10" 3'-11' 11-0" 0' VERIFY MO I VERIFY MO I VERIFY MO VERIFY MO i lei lei loll O 24X24'Y12' CONC.- M _ FTC. W/ #4 BARS \ _ > @ 12" O.C. EA. WAY I N • 81D > S,L — - I • z• - 1 J 1 i a fl, _ @OPT, - r SCREEN — • 2_4, 3._8:3'-102 2 4% ERIMIDFY leiVERIFY MO L I- II � I i I I� I I • I II I II I I • ��� 1 ml i s,D • .I a z 19'_2• •I I I I I II I I I•� - a VARIE II N II I II �Ii- I i II I II 2P -0' „$.. �I I _ ■IIP FIX 8,D S,OJ L I ' 4 _ • • �VERIFV - 81D c� MO L VERIFY MO 't • ��' - 24'x24'xi 2' CONC FTG w/ #4 REBAR C.12" O.C. EA WAY vlFS- R VERIFY MO VERIFY MO I 9I� - 16-8, a' 0' -- '7'-4 3-10" 1P' z_'_ a� ,9-46-4124. OHO Fieldstone \�V3,ApA11 I I �i� 4C.O.A.#ARCHITECURE: N FOUNDATION PLAN - ELEV. "I" / SCALE: 114'-1'-0' AA26002802 NOTES: C.O.E.# ENGINEERING: _\ No. 8 1. 3 1/2' CONCRETE SLAB ON GRADE OVER VAPOR BARRIER 2. REFERENCE FINISHED FLOOR ELEVATION = 0'-0" 29349 3. REFER TO DWG So.1FOR GENERAL STRUCTURAL NOTES O IBRAHEM ELAYEB, PE P.E.# 91476 1, ■ BENJAMIN NIESE, PE 0 STATE OF 14 P.E.# 86025 �i�� �40RID�'. 10/25/2024 /s/10NA1. DATE Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 +1 248,622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae.com 0 0 Y J m rN p J O ~ > wLu LU LO zM J CO Q 0 cD z U) I.- J Cr o° Q LL J Cc U W Q CC Q % $ o� Eli Cc 7 = r-LU N CC L urtrwvry oi. rn� VERSION: 5.0 F T NAME FOUNDATION N - SLAB SHEET # S1.1 I FIRST FLOOR WALL/HEADER PLAN - ELEV. "I" SCALE: 1/4'-1'C' NOTES: 1. REFER TO DWG 80.1 FOR GENERAL STRUCTURAL NOTES ODO Fieldstone C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERING: No. 8 29349 ❑ IBRAHEM ELAYEB, PE .0 - 4,` P.E.# 91476 ■ BENJAMIN NIESE, PE i�O STATE OF �� P.E.# 86025 �i�� !C4ORID�' 10/25/2024//SS�ONA` DATE Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae.com I L _ DRAWN BY: I FAE VERSION: 5.0 SHEET NAME WALL/HEADER PLAN SHEET # S2.1 1 I (2)HETA16 W/ (12)16D. @ SINGLE PLY: SCAB PER R14/S4.1. MGT W/ (22)0.148"X1-1/2" & 5/8" ATR DRILLED & EPDXIED TO CMU WALL W/ MIN. 12" EMBED ROOF FRAMING PLAN ELEV. "I" SCALE: 1/4-1'-0' VOTES. 1. REFER TO DWG S0.1 FOR GENERAL STRUCTURAL NOTES 2. REFER TO DETAILS ON DWG S4.1 FOR ROOF SHEATHING REQUIREMENTS 6 W/ (12) 16D. PLY: SCAB i4A.1 IRO Fieldstone I I' C.O.A.# ARCHITECURE: F AA26002802 C.O.E.# ENGINEERING: No. 29349 O IBRAHEM ELAYEB, PE P.E.# 91476 ■ BENJAMIN NIESE, PE i�0 STATE OF P.E.# 86025 10024 //Sjs�O�iA�. DATE \'? Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae.com z O Lu 1r) O z� J j Q C J LU W J O) z_ p U) w J) U) O LU Q _ U a o} cf) _ Cc W 0 m LU L f DRAWN BY: I FAE VERSION: 5.0 SHEET NAME ROOF FRAMING PLAN SHEET # S3.1 I - STRUCTURAL SHEATHING. SEE PLAN AND �( DETAILS FOR ATTACHMENT / PPE -ENGINEERED 11i2" WOOD TRUSSES — AT 24" O.C. MAX. -OR- 2x RIBBON BOARD 2x BLOCKING AT ATTACHED TO TRUSS SHEATHING EDGES w/ (3) If 8d NAILS INTO TRUSS w/ (3) 10d NAILS, 24" CONTINUOUS G.C. CENTER MAX. STRUCTURAL SHEATHING SPACING NAIL PER TYPICAL CONTINUOUS STRUCTURAL SHEATHING DETAIL SHEATHING NAIL PER TYPICAL SHEATHING DETAIL TYPICALTRUSS J ANCHOR PER PLAN TYPICALTRUSS i DETAIL AT TRUSS HEEL 1 9 4" ANCHOR PER. PLAN NOTE: REFER TO ARCHITECTURAL DRAWINGS AND/OR TRUSS MANUFACTURER DRAWINGS FOR SPECIFIC TRUSS PROFILE INFORMATION. (i.e. HEEL HEIGHTS, SLOPE, OVERHANGS) STRUCTURAL SHEATHING, SEE PLAN AND DETAILS FOR ATTACHMENT PRE-ENGINEERED WOOD 1 TRUSSES AT 24" O.G. MAX. TRUSS ANCHOR PER PLAN FASCIA. (SEE ARCH OWES) BONDBEAM PER PLAN DETAIL AT TYPICAL w/ HEEL < 91/4" E ROOF TRUSS ON MASONRY 11/01/2023 NOT TO SCALE RWM-010 STRUCTURAL SHEATHING, 2X4 BLOCKING AT 2' 0" (SEE PLAN FOR O.C. wl (2) 12d TOENAILS EA. END TO TRUSS 5 ATTACHMENT) PRE-ENGINEERED TRUSSES AT 24" O.G. BOND BEAM PER PLAN AND SCHEDULE SHEATHING PER PLAN 8" CMU WALL, SEE . PLAN FOR VERTREINF META16 AT BLOCKING Rol WALL BRACING @ NOOK EXT. WALL (NWHEM) 11/01/2023 RW11 M-070 STRUCTURAL SHEATHING PER PLAN PRE-ENGINEERED TRUSSES AT 24' O.C. TRUSS STRAP PER PLAN I l'1 11 EXTERIOR IERIOR 8" CMU WALL, - NTSHEATHING PER PLAN SEE PLAN FOR In VERT. REINF. BRACING @ PERPENDICULAR BRG. WALL (NON•SHEM) „/Oia023 RWM-080 NOTE. STRUCTURAL SHEATHING TRUSS ATTACHMENT, VALLEY SET REFER TO ARCHITECTURAL DRAWINGS l ALL TRUSS ENDS ARE TO BE SECURED TO THE EXT. WALL TRUSSES @ 24" O.C. VALLEY SET AND,/Oft TRUSS MANUFACTURER SEE PLAN AND DETAILS BELOW USING ONE OFTHE BELOW METHODS. ONE FULL DRAWINGS FOR SPECIFIC TRUSS FOR ATTACHMENT I OPTION MUST BE USED FOR CONTINUOUS LOAD PATH' 22 1/2' MIN. 9" LONG 20 TRUSSES @ PROFILE INFORMATION. (i., HEEL / a. INSTALL TYPICALTRUSS CONNECTOR THROUGH EXT. RQ' OPTIM L `GA. FLAT STRAP 24' O.C. HEIGHTS. SLOPE OVERHANGS) I PRE-ENGINEERED SHEATHING INTO DOUBLE TOP PLATES. EXT. 30 MAX. TRUSS OR {Q WOOD TRUSSES SHEATHING IS CONTINUOUS AND WILL TRANSFER RAFTER \ ' w/ (8)16d SHEATHING AT 24' O.C. MAX. COMBINED SHEAR & UPLIFT. SDWC156C SHEATHING PER PLAN IS INSTALL TYPICAL TRUSS CONNECTOR FROM TRUSS TO PER PLAN -OR - ? TOP PLATE ON INSIDE OF THE WALL. ADDITIONALLY ,(1j INSTALL LTS12 TOP PLATE -TO -STUD CONNECTORS @ EA _ 2x BLOCKING AT 2x RIBBON BOARD STUD. EXT. SHEATHING IS CONTINUOUS AND WILL I OVERHANG ! OVERHANG SHEATHING EDGES W/ (3) 8d ATTACHED TO TRUSS w/ TRANSFER COMBINED SHEAR 8 UPLIFT. PER PLAN PER PLAN F 2X4 BLOCKING NAILS INTO TRUSS (3) 10d NAILS. 24" O.C. a INSTALL TYPICAL TRUSS SCREWS FROM TRUSS TO TOP 1/2"-i 3/4" UNDER TRUSS CONTINUOUS STRUCTURAL CENTER MAX. SPACING PLATE. EXT SHEATHING IS CONTINUOUS AND WILL ENDS, NAIL TO TRANSFER COMBINED SHEAR & UPLIFT. SINGLE SDI CONFIGURATION A SINGLE SDI CONFIGURATION B SHEATHING NAIL PER CONTINUOUS STRUCTURAL _ TRUSS CHORDS (1) SDWC15600 ,,I (TRUSS OFFSET FROM STUD) (TRUSS ALIGNED WITH STUD) TYPICAL SHEATHING DETAIL ✓ ` SHEATHING NAIL PER w! (3) 11 EA. TRUSS SCREW TYPICAL SHEATHING DETAIL INSTALL THROUGH TOP PLATE INSTALL THROUGH TOP PLATE END. TO EVERY FRAMING PER PLAN �. FRAMING 4'-14'-�-'4`-14` INTO TRUSS/RAFTER INTO TRUSS/RAFTER TRUSS BELOW DETAIL AT TRUSS HEEL > 9 1/4" PER PLAN i STRUCTURAL SHEATHING, TRUSS OR SEE PLAN AND DETAILS FOR _ RAFTER TRUSS OR RAFTER TRUSS OR RAFTER ATTACHMENT 3/4" PRE-ENGINEERED WOOD +/_ /4�, (2) SDWC15600 (2) SDWO15600 (2) SDWC15600 VALLEY SET TRUSSES AT 24" O.C. MAX. TRUSSES @ 24" O.C. m m 4 m I m c<L` ® ` SHEATHING FASCIA, (SEE ARCH DWGS4�!MING SHEATHING NAIL PER +/_, PEA PLANOVERH 3N4 1 1 4" 3 1 1 4 OVERHFLA ANG(% OVERHANG PER PLAN TRUSS ANCHOR PER PLAN rd H S STRUCTURAL 'a '� \ PER PLAN CONFIGURATION A PDOUBLE S2DWCSECONRIGURApN B PEDOUBLE SLANCECON THROUGH FIGl1FtATNN1 D �— -� - - - - 2X4 PURL 3 DOUBLE Sol OM CONTINUO RLIIN @ EA. VALLEY TYPICAL S E AIL PER DETAIL '�- TRUSS, NAIL TO COMMON 3/4" TRUSS w/ (3) 16d GUN NAILS DETAIL AT TYPICAL TRUSS w/HEEL < 91/4"Vi1 20-2�0°-25 (TEN S STUD) (TRUSS ALIGNED WITH STUD) INSTALL THROUGH TOP PLATE INTO TRUSS/RAFTER INTO TOP PLATE BOTTOM CHORD OF VALLEY 22 1/2 22 1/2 INSTALL THROUGH TOP TRUSS/RAFTER TRUSS NAILED TO PURLIN w/ OPTIMAL OPTIMAL PLATE INTO TRUSS/RAFTER - 11 GUN NAIL @ 8" O.C. �� ROOF TRUSS ON FRAMING 11/01/2023 TRUSSIRAFf ER TO DOUBLE TOP PLATE SCREW CONNECTIONS 11/01/2023 �1TRUSS VALLEY SEi OVER FRAME �J ��"~ RWW-020 nva RWW-030 �JNOT"TO SCALE RWG-060 CONTINUOUS CONT 2X4(MIN.)w/ STRUCTURAL STRUCTURAL (2) 10d NAILS SHEATHING PER PLAN SHEATHING, SEE PLAN FOR 2X4 OUTRIGGER AT 24" O.C. REO'D AT ATTACHMENT OVERHANGS GREATER THAN I5". 10d TOENAILS @ ATTACH TO GABLE DROPPED TOP CHORD OUTRIGGER TO rH 35 @ EA. TRUSSw/(3)10d 8" O.C. TRUSS TO w/ TVP TRUSS CONNECTOR PER PLAN ' ' TOP PLATEZONTAL BRACE, TOENAILS EA. SIDE STRUCTUWALL FRAMINGNG TOP PLATE DROPPED TOP GABLE w/ OUTRIGGERS PER PLAN SHEATHING PER PLAN WOOD 2X4 BLOCKING @ CONT 2X4 (MIN) w/ - REQ'D AT 17D MPH OR GREATER EDGE NAILING SHEATHING EDGE (2) IGJ NAILS IN LIEU OF BLOCKING AND w/ (2) 10d @ EA. j END TO ADJACENT 2X4 LADDER FRAMING AT EDGE NAILING SHOWN III TRUSS WEB 24" O.C. READ AT BLOCKING AS REQUIRED WITHIN THE GABLE, IT IS (OR BOTTOM OVERHANGS UP TO 15". FOR BRACING BY TRUSS ACCEPTABLE TO USE CHORD NAILING ATTACH TO TRUSS TOP 1 : MANUFACTURER. "EDGE NAIL SPACING TO AS SHOWN) CHORD w/ (2) 16d NAILS - PERMANENTTRUSS BOTTOM CHORD OF TRUSS / (�/ / BRACING PER TRUSS AT 16" O.C. /II TO TRANSFER LOAD. 2X4 BLOCKING @ _J SEE REQUIRED MANUFACTURER C 10'-0" GABLE TRUSS w/ TOE -NAIL SHEATHING EDGE w/ I./ BRACING PER TRUSS MAX. SPACING, VERTICAL WEBS AS i ADDITIONAL FLAT 2X4 EDGE NAILING / (2) 10d @ EA. END NOTED IN THE MANUFACTURER ( ) SHEATHING - ✓ TO ADJACENT STUD FRAMING SHEET AA A -A (i.e. ISCI BE. HITS) % WITH BLOCKING SPLJCED SHEATHING TRUSS NOTES I'I EXTENDING A MIN. OF (3) TRUSS BAYS PLACED BETWEEN PERMANENT (3) 11 NAILS @ 7 G) 10d NAILS @ TRUSS BRACING CHORD EA. TRUSS CHORD (RESULTING IN 5'-0' MAX. EA. TRUSS PROVIDE 2X8 PT PLATE w/ 112" DIA, x 10" NAIL BOTTOM CHORD OVERALL BRACING) ' OF GABLE TRUSS wl ANCHOR BOLTS @ 4'-0" O.C. MAX wl3"x3" 5 12d's AT 4" O.C. PL WASHERS AND T EMBED. NOTCH HORIZONTAL 2x �• MASONRY HORIZONTAL 2x BLOCKING OVER PLATE, BLOCKING BETWEEN A35 - A35 FIRST 3 BAYS OF PLAN FOR SEE MASONRY WALL, BOND BEAM, LINTEL BEAM. 7J ` OR RAKED BEAM PER PLAN. FOR RAKED FRAMING TO A•A (WOOD) A.A (IAA.40NF11) ATTACHMENT OF ALL ''. BEAM @VAULTED CONDITION. SEE PLAN PERMANENT BRACING STRUCTURAL SHEATHING.; AND DETAIL. W IDd @ 4" O.C. ��GAI3LE END TRUSS BRACING DETAIL 11/01/2023 RWM-090 STRUCTURAL TYp TRUSS SHEATHING PER PLAN - 2X4 LADDER FRAMING AT 24" 2X4 BLOCKING AT DIAGONALS ONLY. ATTACH AT EA. END w/ CONNECTOR O.C. REGO AT OVERHANGS (2) 12d TOENAILS. NAIL SHEATHING TO BLOCKING AT 6" O.C. CONT. 2X4 w/ (2) - PER PLAN GREATER THAN 12", ATTACH TO w/ MIN. 8d NAILS. BLOCK4 BAYS BACK FROM GABLE TRUSS. 12d NAILS I TRUSS TOP CHORD w/ (2) 16d WHEN SECOND BRACE IS REQUIRED, J i NAILS AT 24" D.C. NAIL TO OPPOSITE SIDE OF BLOCKING. SEE REQUIRED i- BRACING PER TRUSS �� STRUCTURAL I 1. AT VERTICALS 3'-6" TO 6'-6" USE ONE 2X4 "L" BACK. MANUFACTURER SHEATHING I PER PLAN 2. AT VERTICALS OVER 6'-6" TO 8'-4" USE (2) 2X4 "L" BACKS H EA. SIDE) (OR FRAME PER CASE 3 BELOW). 3. AT VERTICALS OVER 8'-4" TO 1S-0" USE ONE 2X4 "L" BACK ALT. OUTLOOKER FRAMING AND AN ADDITIONAL DIAGONAL BRACE IS REQUIRED AT THE (REGO AT 170MPH OR GREATER) /'// PEAK AND AT EVERY OTHER VERTICAL MEMBER IN THIS 3 RANGE. ATTACH THE DIAGONAL AT MID. HEIGHT AND TO THE CONT. 2X4 w/ (2) 12d NAILS BLOCKING BELOW THE ROOF SHEATHING w/ (5) 12d's AT EA. END. IN ADDITION TO THE SECOND DIAGONAL, A STRUCTURAL SHEATHING SEE PLAN FOR STRONGBACK IS ALSO REQUIRED AT THESE VERTICALS AND PRE-ENGINEERED WOOD ATTACHMENT OF MUST BE ATTACHED TO EA. "L" BACK WITH (2) 121 AND ONE TRUSSES AT 2'-0" O.C. MAX. t ALL STRUCTURAL SIMPSON HIS OR ONE USP RTS CONNECTOR. (SHEATHING. FASCIA SIDE NAIL ALL "L" BACKS AND STRONGBACKS w/ 12d'e AT 6" (SEE ARCH. DWG.) 2x SIFTS. 0-C. NOTCH "L" BACKS AT TOP AND BOTTOM. BLOCKING PRE-ENGINEERED WOOD -I - RUNCHOR TRUSSES AT 2-0" O.C. f� fT° MAX. LL PER PLAN I FASCIA (SEE ARCH. DRAWINGS) J I SHEATHING PER PLAN TRUSS ANCHOR PER PLAN FRAMING PER PLAN PARTIAL WOOD BEARING DUTCH HIP TRUSS BRACING DETAIL @WON HIP) 11101//22023 Rio RWM-100 2 3 9 l (8) 10d NAILS ,� '1 O EA. STRAP /� ENGINEERED WOOD ROOF G V 2 2 9 2 2STRAPS / 2 O / TRUSS AT 24, O.C. MAX. WHEN QUANTITY OF MISSED TRUSS MISSED EXCEEDS (5) Q J 2 3 � 2 I"I _ CONSECUTIVE LOCATIONS. INSTALL HGAMI0KTA w (4)-1 /4"x2 3/4" MASONRY NDBi GAME1 2 O 2 R O \ I SCREWS TO TOP OF WALL & (4J-1/4"x1-1/2" SDS SCREWS TO TRUSS END 1 ill TO AFFECTED MISSED TRUSSES 3 GAM IW K0212706:14 GAM P" PRCHT:12T012'12) HIP a J �( TYPICAL CMU WALL III SHEATHM NIBS I 11"FA15IBR MISS 1, WE"PlIHIFE£TNAtLGSES 1 2 3 FfGSHAN(NAOS: PANEL EDGE B'OG. B'O.C. 3'O.C. 19192'SH6LYWOOD OR0SPAN � w31'r&1fr II PANEL FED WMR I 3.O.0 3'D.C. 3'O.C. RATED PLYWOOD OROSB) I 4211 HEADOW FOR Ii W MWS W 170 PH OR GMTM EN& FNMUBECOL ALL MINES Va. 1. WOOD SDEICRANLPANETS USEDAS ROOF SHEATHNDMBE NSTALIEDWRH JONIS ROOF FRAYINGMEN M 87ROOF SHEATHING ATTACHMENT DIAGRAM 11101= SCALE RWG-112 (1) SIMPSON HTSM16 (OR APPROVED EQUAL)AT EA. MISSED LOCATION (4) 1 /4.0 x 21 /4' MASONRYSCREWS AT EA. STRAP CONDI OF USE: 1. UPLIFT VALUE FOR TRUSS LOCATION DOES NOT EXCEED 1, 110 ft. UPLIFT. 2. NOT ACCEPTABLE ON MULTI -PLY TRUSS APPLICATIONS. IF FIELD CONDITIONS EXCEED CONDITIONS OF USE, CONTACT ENGINEER OR ARCHITECT OF RECORD FOR APPROPRIATE SOLUTION. R13 MISSED TRUSS STRAP REPAIR 11/01/2023 NOl SCALE RWM 130 111111111 020 Fieldstone 3, C.O.A.# ARCHITECURE: `� F AA26002802 C.O.E.# ENGINEERING: No. 29349 ❑ IBRAHEM ELAYEB, PE P.E.# 91476 ■ BENJAMIN NIESE PE �0 STATE OF P.E.#86025 i�� '•p�ORID� 1024 DATE/,sS��NA�. _ �Ec "FE O Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae.com O O Y J m Z O Lu n O J > z CO co � Q LU LU z Fn Cl U W ~ L'u J W Q a LU Q Cc o0 GO L GO } J U _ o� in Cc LLJ (D S d M N O IY F_ L- DRAWN BY: I FAE VERSION: UO SHEET NAME DETAILS - ROOF SHEET # S4.1 2X6 SP #2 SCABS (SIDE -BY -SIDE) ATTACHED TO TRUSS WITH (3) 10D'S @ TOP AND BOTTOM. SCABS REQUIRED FOR FULL CONNECTION NAILING. FASCIA (SEE , ARCH. DWG.) IIM � BOND BEAM OR LINTEL PER PLAN TRUSS GIRDER CONNECTION WI SCAB PRE-ENG. TRUSS PER \ PRE-ESTRAP G.TRUSN MANUF. MANUF. STRAP PER PLAN, ONE EA SIDE OF TOP PLATES, PRE-ENG. TRUSS PER MANUF —j WRAP AROUND TOP STRAP PER PLAN PLATES. (2) 2x-TOP PLATE (2) 2X -TOP PLATE STRAP PER PLAN SIMPSON SPIT STUD PLATE FULL HEIGHT STUD (2) 2x-TOP PLATE TIE w/ (12) 0.14"1-1/2" COL. PER PLAN, NAILS, SIZE TO MATCH STUD EXCEPT MIN. COL. FULL HEIGHT STUDS PER PLAN- ~ SIZE. ONE EA PLY OF J' PLY COUNT TO COLUMN PER PLAN. MATCH TRUSS PLY I.L.O. FULL HEIGHT STUD: ALIT 48" LONG I COUNT +1 2xVERTICAL SCAB MATCHING COL. NOTE : ENSURE NAILING IS NOT FULL HEIGHT STUDS PER ONE STRAP EA SIDE OF DEPTH w/(2) ROWS OF 16d NAILS @ 6" INSTALLED IN AREAS WHERE PLAN WALLDIREOrTO STUD O.C. STAGGER ROWS 3" STRAPPING IS OVERLAPPING BOTH STRAPS ON ONE STRAP EA SIDE OF WALL HTERIOR SIDE OF WALL WRAPPED TO PLATE NOTE : REFERENCE TO FULL HEIGHT STUD COLUMNS IN THIS DETAIL MAYBE SUBSTITUTED BY PSL COLUMN PER PLAN AS RED'D WHILE MAINTAINING STRAP INSTALLATION CONFIGURATIONS, ADDITIONAL STUD OR SCAB MAY BE REQ'D FOR PROPER STRAP ATTACHMENT PER DETAIL INTENT. TYPICAL GIRDER TRUSS TWIST STRAP INSTALLATION CONT- 2X4 w/ (2) TYP TRUSS 12d NAILS CONNECTOR PER PLAN STRUCTURAL SHEATHING PER PLAN ALT. OUTLOOKER FRAMING SEE REQUIRED (REG'D AT 170MPH OR GREATER) BRACING PER TRUSS MANUFACTURER STRUCTURAL GOUT. 2x FASCIA PER SHEATHING PER PLAN TLED ARCHS w/ (2) 12d NAILS 2X BLOCKING BAYS BACK THREE TRUSS BAYS BACK PRE-ENGINEERED FROM GABLE END 2X4 PURLIN @ WOOD TRUSSES AT 1 EA VALLEY STRUCTURAL SHEATHING 2'-0" O.C. MAX. PER PLAN I TRUSS. NAIL TO 2x BLOCKING TOENAILED. BOTTOM CORD OF VALLET COMMON 3 TRUSS BAYS BACK TRUSS NAILED TRUSS WI (3) FROM GABLE END I TO PURLIN w/ 10d GUN NAIL 16d NAILS STRUCTURAL 2X4 BRACE CONT. 2x FASCIA PER 8" O.C. SHEATHING PER PLAN ARCH w/ H25A @ EA. OVER _ (2) 12d NAILS pp FRAMED TRUSS H2.5A @ 6'-0" O.C. MAX y 2X4 BLOCKING SHEATHING PER PLAN PRE-ENGINEERED WOOD $$ TRUSSES AT 2'-0"O.C. MAX �i 4 BETWEEN TRUSSES TRUSS ANCHOR SONOTW EN,7�tIR&ES MASONRY CONTINUOUS EA. END 8" CMU WALL OR LINTEL, SEE SHEATHING _PLAN FOR REINFORCEMENT R B EDGE NAILING BRACE H2.5A @ EA. TRUSS TIE PER PLAN PER PLAN OVERFAMED TRUSS H1OA @ EA END Emm(2) SDWC15600 HANGER OF VALLEY 110 SCREWS T FROM PER `` TRUSS & 10' - 0" EDGE NAILING j / TOP PLATES O WOOD MANUF. O.0. MAX PER PLAN �/ TRUSS @ 16'TM 2X4 FRAMING PER PLAN O.C., (1) EA PLY. FRAMING SHEATHING SHEATHING, SEE PLAN WOOD PER PER PLAN FOR ATTACHMENT PLAN ��OVEWRAMED GABLE END DETAIL MOD (11/30/2023) eTYP."GABLE END DETAIL (MOD) 11/30/2023 RWG-202(RB-449) RWG-203"(RB-449) 03/27/2023 R W W-601 COO Fieldstone C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERING: - 29349 O IBRAHEM ELAYEB, PE P.E.# 91476 ■ BENJAMIN NIESE, PE P.E.# 86025 10/25/2024 DATE ````IIIIIIII//// No.8 r 0 �p �4: _ STATE OF Q/ �4ORIDP'. iS1�NAL IE? Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae.com (D O Y J fYl Z 1-- O_ Lu O J j zC0 Q Q Z C/) O U W — ~ W W a J Q CC Q 0 Q LL i J U) _ o¢ 11J 00 0 coN O DRAWN BY: FAE VERSION: 5.0 SHEET NAME DETAILS - ROOF SHEET # S4.1.1 01 � r --------------- -- -- - -- , INT FINISH WOOD BUCK ATTACHMENT: ALTERNATE: EXTERIOR WALL SHEATHING EXTERIOR WALL SHEATHING 1x CUSTOM P.T. BUCK To 2x OR GREATER BLOCK TO EXTERIOR CMU WALL SHEATHING NAIL PANEL EDGE FIELD . BLOCKING FIELD BLOCKING ( _ ., / 1x P.T. BUCK MATCH FRAME WIDTH. THICKNESS 12�-- -- ix WOOD MASONRY BUILT REQUIRED MIN. SIZE 3AIO.0 SPACING: () PANAILNG E SPACING REQUIRED, L FROM ENDS AND ,2"O.C. SCREWS x4'MASONRY- a. 4" 1/4' = 1 I MASONRY ATTACH w1 T' NAILS' l4 T REQUIRED SHEATHING 'NAIL - _ 8d ALL EDGES REQUIRED MIN SIZE ATTACH @ 4' FROM ENDS j GARAGE DOOR AND - SHEA HING Yi16" WINDOW PER REMAINDER. ATTACH AND 12' O.C. REMAINDER. TRACK, INSTALLED PER _ Stl 3" O.C. 12' O.C. ALL EDGES - SHEATHING - _ FLORIDA WINDOW THRU BUCK INTO w/ 1 1/4' EMBEDMENT MANUFACTURERS 1 PRODUCT MASONRY PER FLORIDA SPECIFICATIONS.( j PANEL EDGE NAILING - S SPJGiZML PRODUCTAPPROVAL NOTE: PROVIDE BLOCKING - GEALANT AT ALL SHEATHING EDGES S - FINISH PER ELEVATION Ij.j � 1,, -•- -- ' 2X6 WOOD BUCK ANCHORED j I,'j TO CM U w/ 1/2' x 6'' L' BOLTS OR 5/8" x 6' SIMPSON TITEN �. STRUCTURAL MI '38 STRUCTURALFIELD NAILING. li 3/8" W14 TYPICAL WINDOW ATTACHMENT DETAIL 1 O C &WITH NSHEATHING HD'S�f S6' OF TOP AND FIELD NAILING 12/17/2021 FRAME TO BUCK __ „„,,,, BOTTOM, OR (2) ROWS OF 1/4" SHEATHING TVP. N.T.S. WGM-140 TO MASONRY x 3" MASONRY SCREWS @ 12" SINGLE NAIL O.C. STAGGER ROWS 6" \ SI G NAIL EDGE SPACING 1 EDGE SPACING EXTERIOR CMU WALL 1, 1/2 S INT. FINISH t WOOD BUCK ATTACHMENT'. j 2X OR (TREATER BLOCK TO MASONRY 1/4" DRIVE-IN ANCHOR 1. WOOD BUILT-UP THICKNESS a 21/4' = 1/4'k4" GARAGE DOOR AND ._ .-._. --1 j 2x P.T. RUCKMASONRY SCREWS C E FROM ENDS TRACK, INSTALLED PER 1 • �4. - 1 REMAINDERw 7 1/4' - AND 2 O.C. / -, ' MANUFACTURERS ) I M FOMENT _ E 8 T -_ ATTACH DOOR PER SPECIFICATIONS DOUBLE NAIL EDGE SPACING FLORIDA PRODUCT _ -- 'ALTERNATE: , APPROVAL O 1 1 1'2 x 21/4 HILT( SLEEVE 2X4 BLOCKING 1x PT Bl1C1CTO MASONRY > CUSTOM STUDS PANEL EDGE AL MIN. 1 1 2' w T � '�- - ANCHOR OR EQUAL i NAILING / MATCH FRAME WIDTH. ATTACH / G r PER PLAN M I MASONRY 7 PER SHEATHING SPLICE SAME / EMBED INTO BRIn N 1 NAILS a 4 FROM ENDS A D 2 0 C3 12'BOTTOM �.THICKNESS AND STRENGTH AXIS / �BRACKET NAILING MOREMAINDER. ATTACH DOOR THRU j, PER PLAN ORIENTATION AS WALL SHEATHING CHORD BUCK INTO MASONRY PER FLORIDA FRAME TO ', FINISH PER -I MASONRY : ELEVATION (PRODUCT APPROVAL L� TYPICAL SHEATHING DETAIL 11/01/2023 GABLE END SHEATHING DETAIL 11/01/2023 TYPICAL DOOR ATTACHMENT DETAIL 11 /01 /2023 TYPICAL GARAGE DOOR ATIACHMENi „/01 /2023 W01 W02 W15 .4Nm. W16 ,.,,. NOT TO SCALE WGW-010 NOTTO SCALE WGG-020 WGM-150 NOT TO SCALE WGM-, 60 T.O. BOND BEAM COMMON WALL, PER PLAN (TVP.) 8 x B x i6 CMU WEAVE BLOCK COURSES EVERY OTHER BLOCK (TYR.) @ EVERY HHB #S REBAR. CONT. BLOCK TEE INTERSECTION REBAR PER IN BOND BEAM REBA BOND BEAM PER PLAN #5 REBAR HOOKED DOWEL 1 � ' IETYPICAL"IINTERSECTIONDETAIL IIM1/2023 #5 REBAR VERTICAL 18B """ "'"'"' -- - IN SOLID FILLED WGM-182 CELLS, (SEE PLAN) #5 REBAR HOOKED DOWEL 3" x 5" CLEAN OUT AT ALL FILLED CELLS SEE FOUNDATION PLAN AND DETAILS FOR FOOTING REINFORCING. ROUGH OPENING d BELOW PRECAST LINTELS FILLED WITH GROUT LINTELS BY fMITER FIELD CUTTING -- #5 REBAR IN VERTICAL GROUT FILLED CELL #5 CORNER DOWELS INSIDE Of AND OUTSIDE OF VERTICAL #5 BAR AS SHOWN 2: IZ 01l 0 3 O 0 m CW, 9 TYPICAL REINFORCED FlLLED CELL DETAIL 11/01/2023 W25 0 DEG. CRNR DETAIL wl COLUMN BEL 2/28/2022 NOT TO SCALE WGM-190 WGM-250 INTERIOR STRUCTURAL SHEATHING. REFER TO R11/S4.1 FOR NAILING & OTHER REQUIREMENTS INSULATION AS PER SPEC. PRE-ENGINEERED ROOF TRUSSES. REFER TO TRUSS MANUF. DWGS ASPHALT ROOF SHINGLE (OR TILE PER SPEC.) TRUSS STRAP PER ROOF FRAMING PLANS ON S3.1 & DETAILS ON S4.1 SHEETS FASCIA PER COMMUNITY SPEC SOFFIT & OVERHANG PER SPEC. BOND BEAM PER FIRST FLOOR LINTEL PLANS ON S2.1 & DETAILS ON S4.2 SHEETS SOFFIT PANELS < 2'-0" MIN. 2X2 VERTICAL BRACE C. 24" O.C. MAX SPACING. ATTACH TO EA ROOF TRUSS W/ (2) BD NAILS. MIN. 2X2 HORZ BATTEN, IF REO'D PERM NUF ATTACH TO EA VERT. BRACE W/ (1) 10D NAIL (24" O.G. MAX SPACING) PANEL ATTACHMENTS PER MANUF. MIN. 2x2 VERTICAL BRACE @ 24' O.C. MAX SPACING. ATTACH TO EA ROOF TRUSS w/ (2) 10d NAILS. MIN. 2x4 HORZ BATTEN, IF I REO'D PER MANUF. ATTACH TO EA VERT. ( BRACE w/ (2) 10d NAIL (24" O.G. MAX SPACING) PANEL ATTACHMENTS PER MANUF. - WALL CONSTRUCTION PER FIRST FLOOR LINTEL PLANS ON S2.1 AND DETAILS ON S4.2 SHEETS 2'-0" < SOFFIT PANELS a 3'-0" INSTALL MID -SPAN BLOCKING (BATTEN) EXTERIOR WHEN REQUIRED BY MANUFACTURER - WALLCONNECTION PER FOUNDATION PLANS ON S1.1 AND DETAILS ON S1 0 SHEETS 0'-0" FIN. FL. - FINISHED GRADE - MONOLITHIC END. PER FOUNDATION PLANS ON S1.1 AND DETAILS ON S1 0 SHEETS sot TYPICAL( STOAYWALLSECTION 09/12w2024 NOT TO SCALE WSM012 STRUCTURAL SHEATHING, REFER TO R11/S4.1 FOR NAILING & OTHER REQUIREMENTS INSULATION AS PER SPEC. PRE-ENGINEERED ROOF TRUSSES. REFER TO TRUSS MANUF. DWG 12 PER ASPHALT ROOF SHINGLE ELEV. (OR TILE PER SPEC,) TRUSS STRAP PER ROOF FRAMING PLANS ON S3.1 & DETAILS ON S4.1 SHEETS FASCIA PER COMMUNITY SPEC. SOFFIT & OVERHANG PER SPEC FOND BEAM PER FIRST FLOOR LINTEL PLANS ON 52.1 & DETAILS ON S4.2 SHEET PRECAST LINTEL PER FIRST FLOOR LINTEL PLANS ON S2.1 & DETAILS ON S4.2 SHEETS OPENING w/PRECAST SILL PER PLAN WALL CONSTRUCTION PER FIRST FLOOR LINTEL PLANS ON S2.1 AND DETAILS ON S4.2 SHEETS INTERIOR EXTERIOR WALL CONNECTION PER FO ON S1.1 ANND DETAILS ON SSO SHEETS 0'-0' FIN. FL FINISHED GRADE MONOLITHIC FAD.. PER FOUNDATION PLANS ON S1.1 AND DETAILS ON S1.0 SHEETS YPCORYWSO 30 o9n 2/2024 WSM-021 OHO Fieldstone O��� �.• C.O.A.# ARCHITECURE: AA26002802 N''F _ ! C.O.E.# ENGINEERING: _ No. 8_ 29349- O IBRAHEM ELAYEB, PE 1 P.E.# 91476 ■ BENJAMIN NIESE, PE -,0 STATE OF �(/\ �i�� F4011110Q' P.E.# 86025 • ���� 10DATE 24 S'O:�iA1. Michigan 3400 Auburn Rd Suite 200 Auburn Hills MI 48326 +1 248 622 4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa; FL 33637 +1 813.466.3310 www. iieldstoneae. com Z � I— 2 Lu O a z� -� > _3 Q W _U CC z p LL Q LL J } W U) Ir Q C/) _ L) G p Cn C7 2 V w ^ LLI N F- O CC L _ DRAWN BY: FAE VERSION:5.0 SHEET NAME DETAILS - WALL SHEET # S4.2 LEGEND �I 8x8 FILLED CELL W' (1) - #5 REBAR - - - - BEAMS 8.8 FILLED CELL W1 (1) - #7 REBAR ' HEADER - WIDTH TO MATCH WALL -- ------- GIRDERS 8.8 FILLED CELL W1 NO REBAR REOD -- ------ PLUMBING WALLS (FOR REFERENCE) BEARING/SHEAR WALLS (FOR REFERENCE) 45' CMU - FILL CELLS WI #5 REBAR ROOF BLOCKING CELL W/ #4 REBAR CI ggLLOON FRAMED BALLOON (IN WALL) FILLEDCELL W/ #4 REBAR WALLS/HIGHER BEARING WALLS (IN CONCRETE TIE BEAMS Ailli�5LEV ELEVATION INDICATOR ® PLUMBING PENETRATION FOR FRAMING LAYOUT DETAIL INDICATOR HDR SIZE LINTEL OR WOOD HDR DESIGNATION OPEN SIZE (ALL WOOD HDR'S TO BE (2) PLY U.N.O.) (P)- BRACED WALL LINE ABBREVIATIONS: AB ANCHOR BOLT EA EACH INT INTERIOR AFF ABOVE FINISHED FLOOR ELEV ELEVATION JST JOIST ALT ALTERNATE EMBED EMBEDMENT MAX MAXIMUM APP FOX APPROXIMATE EN EDGE NAILING MFR MANUFACTURER ARCH ARCHITECT/ARCHITECTURAL EQ EQUAL MIN MINIMUM ATR ALL THREADED ROD ES EACH SIDE MSC MISCELLANEOUS BILK BLOCK EW EACH WAY MO MASONRY OPENING BLKG BLOCKING EXP EXPANSION NOM NOMINAL BOF BOTTOM OF FOOTING EXT EXTERIOR NITS NOT TO SCALE ROT BOTTOM FD FLOOR DRAIN OC ON CENTER BRG BEARING FDN FOUNDATION OPNG OPENING BTWN BETWEEN FIN FINISH OPP OPPOSITE CANT CANTILEVER FILE FLOOR PEN PLYWOOD EDGE NAILING CL CENTERLINE FN FIELD NAILING PLYWD PLYWOOD CIP CAST IN PLACE FT FOOT / FEET REINF REINFORCING/REINFORCEMENT CJ CONTROLJOINT GALV GALVANIZED READ REQUIRED CLR CLEAR GDR GIRDER RO ROUGH OPENING CMU CONCRETE MASONRY UNIT GRD GRADE SC STUD COLUMN COL COLUMN GWB GYPSUM WALL BOARD SHTG SHEATHING CONC CONCRETE GYP GYPSUM SIM SIMILAR CONT CONTINUOUS HD HOLD DOWN SP SOUTHERN PINE #2 OR BETTER DBL DOUBLE HIDE HEADER SPF SPRUCE Pill FIR #11#2 OR BETTER DIA DIAMETER ILO IN LIEU OF TYP TYPICAL DWG DRAWING IN INCH UNO UNLESS NOTED OTHERWISE 140 WINDSPEED CHARTS 2020 FL - C & C Pressures (ASD) 9ASED UPON 10 SOFT AREA Roof Pressures Wall Pressures Gable Roof Pressures Hip Roof Pressures Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 19.1 -36.4 N/A I N/A 19.1 1 -47.3 19A -34.2 N/A I N/A 19.1 -473 25.7 1 -27.7 1 25.7 -34.2 Zone 2e Zone 3e Zone Ze Zone 3e 38.2 1 -83.7 19.1 -58.1 19.1 Zone 2n Zone 3r Zone Zn Zone 3r 19.1 1 -58.1 19.1 -69.0 N/A N/A N/A N/A Zone 2r Zone 2r 38.2 1 -105.4 19.1 -47.3 Components and Cladding Pressures (ASD) - 2020 FL Positive Ne ative Width Height Effective Pressure Pressure 3080 PRECAST LINTEL GRAVITY LOAD TABLE v4.21 CONNECTOR FASTENERS ALLOWABLE LOADS CITY TYPE GRAVITYTERAL llbs) 1.0 UPLIFT (Ias7 1.6 ILAibs) @ 1-6 LOADS LISTED PAVE BEEN CALCULATE D O R C OMP iLED F ROM APPROVED MANUFACTURERS: CAST-CRETE,LOTT'S CONCRETE, QUALITY PRFCASTCO. META16 8 0.148"xl-1/2" 14SO f2.770 -) HETA16 9 0.148'z1-1/2' 1810 FL 340 _CLEAR] ENING TYPEA 8'LNTEL 8'TYPfB .�_. :1.9*Ti'P C: d7TWE814"TWEE "12°TYPEC 14',7YPEC 16"TYPES „1B': PErC, 20'TYPEB ;7�5'P.EC 24TYPEB .. .TyPE'C 28, TYPE 281TVKC 3Y'TYPEB 32°TYPE C. (2)META16 10 1875 F1:690 F2:770 t'6' 2231 3069 3719 3280 5163 fi607 W54 9502 10000 (2)META16 - ,3- SA .x3-1/2" 0162" 1796 F1. 1285 F2: ; 4fi66 -SYD6 �113 � 8974 ]DOOD ' 1DODO )'2" 2231 ,3D69 3069 3719 3280 5163 5647 8054 9502 10"20 "1 NETA15 DO 0.148"x2-1/2" -- 7920 F1 . 680 i 4l'i1Yi � $206. " 374= " 30DPiD I00DD . " E (2) HETA36 2-or 3- 12 0.162"z3-1/2" -- 2365 FI: 1350 12: 1430 ?'8" 1783 2561 2751 3280 3220 4890 5961 7034 8107 .k ,y„ HSTMS6 9 0.148'xl- 2' 1110 F1 : 120 F2: 90 1969 2110 2992 3931 3756 4576 5400 6224 4 £J4k1-374"GONG SCREW 3' 2" 1343 &W8w LGUM28-2 6 378' x4' P,TEN HD 8250 2439 3'4" 1217 � 1349 1438 1716 1934 2560 3732 3686 4249 6 114 x 2 1/2" SDSSCREW " 1349.z ',-3D9D 4567 ,,. ,' 3fiv'.., ,...:r5'5$i `', ;.,-jD74 : '. 8203 :w NISTC28 36 4 D.?48'x31" 3460 MTS12 14 0.148"z1-1 2" - 990 - 10" 1006 1349 1438 1716 1999 2560 3132 3686 4649 (2)MT512 28 0.148"zl-1/2 - 2980 - '..33442" 309D ';4567 ;'S"3Ci ..�-#b5. ., ,z"5817;:,.:' 7074 ffi06 MTS16 14 0.148"zl i 2" -- 990 t'6" "a ll05 1173 1600 1631 2090 2549 3D09 3470 HU 2162 18 ' 114'z23/4"CONC SCREW 3504 £800 - .,.17,05 '.;'2622 ,.4242 "< L'-4884 6817 666Y 16 i D'48'z3" >'2" � 710 1232 2177 3738 3490 3031 3707 4383 5061 HTS16 32 � 0.148"x1-1/2" - 2,890 - ,232' 2177 .:273$ `3484 .. ti1 .`_`. -836D`' 862i. i59D (2t HTS16 Ib 0-148"xi-i/2" - d310 s'2" 570 991 1729 2108 2632 2205 2698 3191 3 885 HTS20 24 0.148"zl-1 2' -- 1316 -- " •94i : 1729 ":::2168 " -:;S56i; 4742. : - 5501 ... LSTA12 SO 0.148x2-1/2 -- 92S - rD" 488 699 1160 1516 1626 2564 3486 2818 3302 LSTA18 m j 0.148"x2-1 2" -- 1235 - :649. ;. %: 11A5 =1516 ..`."24: ' ,.3483�• .2964 3387 ,- tSTA30 22 0.148"z2-1/2" - Sb40 MSTA24 18 0.148"X212" -- -- YO" ( 416 699 SdFA N/A 1625 2564 3486 7818 3302 2 MSfA24 36 0.346"X21/2" - - ;NIA S>5443. "087, G MSTA36 26 0.148" X 21/)" -- M4,100 - 1 2" 354 535 890 N/A 1247 2C7}3 2777 2163 2536 2 MSTA36 52 0.148" X 2 1/2" - - a.,'L535., .�2259 .'s, ,. `d615 "%; NISTA30 22 Cr148"z2-112" 20SO 567 890 N/A 1366 1846 2423 3127 4006 MSTC29 36 0-148" z 3 4" - 3,460 -- 0101 315 3, .1 MSTC52 62 0.148"x3-1/4" 4736 018' 292 525 873 N/A 1254 1684 2193 2805 3552 MSTAM24 9 0.148"X 3" -- 1A25 S 1 4" X 2 k 4' MSTAM36 13 0.148"X 3" 1870 1'2" 277 471 755 N/A 1075 1428 838 2316 2M 8 Sa"X24 1" - - 2883 3: (2)MSTAM36 26 0.148"%3" -- 3740 _. T 0" 255 471 755 N/A 1075 1428 1938 2316 2535 16 1 4" X 2 14" " ....: e}., ":.; MSTCM40 10 1/4N2-1/4" CONIC SCREW - 2 -- 239 424 706 N/A 1002 1326 1697 2127 2278 7A 0.148"z}3/4" " wk 7 `1Ef62T" : `a;,„ '..2Ai7'7` 2127:.., '2636 m MGT 22 0.148"z3' -- 3965 F1 F: 775 2. 525 N/A N/A N/A N/A N/A N/A N/A N/A 1 5/8'ATR 3'4" NIA a 'Nlt+ ' 783� 'NjA ' „7234` -.". �. ,.1379' 2198;' 2862' v HGT-3 16 0. £43"s3" -- 10,790 -- 4'0" NIA N/A N/A N/A N/A I N/A NIA N/A N/A 2 3/4'ATR VGTR or L 1 5/8"ATR _ 2225 f2: 650 F2: 63D 1,_-lfJ,rf 710' : ,q ,. tGO �, , 3.331.,,. `i664` ` "373b`.:' 2A59' 1 6'0` N/A N/A N/A N/A N/A NIA N/A N/A N/A VGTR/L 2 2 /8-ASOS S/8"ATR - 5S45 F1.650 F2: 630 A :'548` '-:N z852!` Tom" ,-1-S3JtJ#: 3671' �3997' : 32 14"x3'SDS 8'0" NIA N/A N/A N/A N/A N/A N/A N/A N/A Vol £ S/8"ATR 4940 F1. 1185 F2: 590 i ."^ ii ; »�, 426°' '. ; ' 2N/ .. ^'' 1^ .?t•:: �� �..+, . #,Y? �•:, x 141A I, ,1`6764",.' 16 1 4"x3" SOS 8'8" N/A N A N/A N/A N/A N/A N/A N/A N/A t2)YGT 2 5/8"ATR - 7185-2PIV 8890- 30Y F1: 1185 FZ 590 1' rc u.18/15.`r„2 .=1468*. ,rc 32 1/4"0" SOS NjA N/A NIA N/A NJA N/A N/A N/A DTT2Z F 8 1/2"ATR 314"x3"SOS 1825-2x4mkn 214542 )2X4 min 2'8' NIA _.. 3"W/rRECESS U-LINTBS Behar; Type B =Continuous Grout, Steel per Plan In Bond Beam Only; Type C=Continous Grout,Steel per plan in Bond HT74 1 5 "ATR _ 3610 l8 I O. 148"z3-1/2" HITS 1 S/8"ATR - 4670 -- 26 0. 148"x3" HTT5KT I S/8"ATR -- 5A.85 26 SD 410x2-1 2" ABU44Z T ATR 7570 1900 62" ASU66Z 1 6!8" ATR 1820S 247S - Z2 0.162"x3-1 r'. H2.54 10 0-131"z2-1/2" __ 565 FS.110 Fz. uD H10A 18 0-148"x1-1/2" __ 2340 Fl: S65 F2 : 285 H14A-2 18 0.148"xl-1/2" - 2080 FI:680 F2: 260 HUC48 14 1(4'k2-3/4" CONC SCREW 35� 1135 -- O@O Fieldstone �p C.O.A.# ARCHITECURE: AA26002802 C.O.E.# ENGINEERIN No. 29349 ❑ IBRAHEM ELAYEB, PE / C P.E.# 91476 ■ BENJAMIN NIESE PE ��O STATE OF ��� P.E.# 86025 �i�� ' !C4ORII���� 10/25/2024/ss/DNA` F.? DATE O@O Fieldstone Michigan 3400 Auburn Rd Suite 200 Auburn Hills, MI 48326 +1 248.622.4035 Florida 12906 Tampa Oaks Blvd. Suite 150 Tampa, FL 33637 +1 813.466.3310 www.fieldstoneae. corn DRAWN BY: I FAE VERSION: 5.0 SHEET NAME - REFERENCE ` CHARTS SHEET # S5.1