Loading...
HomeMy WebLinkAbout3039 Lytton Hall Dr (2)I . � I 19 � I a k a s 7.36kW SOLAR ARRAY PLANS FOR COURTNEY CAMPBELL 3039 LYTTON HALL DR ZEPHYRHILLS, FLORIDA 33540 PROJECT DESCRP.ION: 23 MODULES MISSION SOLAR: MSE320SR8T . 23 INVERTERS HASE: IQ7-60-2-US ENP GOVERNING CODES: 2020 FLORIDA PLUMBING CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE, 7TH EDITION 2020 FLORIDA MECHANICAL CODE, 7TH EDITION NEC 2017 NFPA 1 2018 GENERAL NOTES: 1. THIS IS TO CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS CONFORM WITH FLORIDA BUILDING CODE 2020 WITH ALL SUPPLEMENTS AND ADDITIONS. 2. ALL PRODUCTS TO BE INSTALLED PER MANUFACTURER'S WRITTEN SPECIFICATIONS, 1, ANDREW D. HALL PE# 87479 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FRC, FBC 107> Wind Design Data Wind Speed 140 mph Risk Category H Exposure C Gust Factor ±O. 18 "A" Dimension 5.1 ft Roof Pressure for Components and Cladding Zone 1 16,47 psf -25.65 psf Zone 2 16.47 psf -44.55 psf Zone 3 16.47 psf -66.15 psf DRAWING INDEX: No 479 • TA E 0 F 0 - C S-1 COVER S-2 ARRAY LAYOUT & DETAILS S-3 ELECTRICAL S-4 NOTES S-5 SPECIFICATIONS S-6 SPECIFICATIONS S-7 SPECIFICATIONS S-8 SPECIFICATIONS V) r2 z M C) Z H oq =1' oe - w (5 LU = Z z U-) 'ate.r� LU V) Uj CD CY z Z) W. NO. S_ 7 C) PV MODULE 3/8"-16 X 3/4" HEX HEAD BOLT 3/8" - 16 FLANGE NUT SUNMODO NANO RAFTER MOUNT (-�p) QMR-UMC CLIP QMR CROSSRAIL LIGHT ---EXISTING UNDERLAYMENT EXISTING ROOF TRUSS 1,0K �1/2' PLYWOOD 5/16" DIA SS LAG SCREW/ 2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT NTS SUNMODO NANO RAFTER MOUNT (TYP) MAX. O.C. SUNMODO NAN RAFTER MOUI\. (TYP) QMR-UMC CLIP (TYP) TOP VIEW NTS QMR CROSSRAIL LIGHT (TYP) - cn QMR-UEC MISSION SOLAR: MISSION SOLAR: cif :2! (TYP) MSE320SR8T QMR-UMC CLIP MSE320SRBT (Typ) (TYP) (TYP) SUNMODO NANO RAFTER MOUNT (TYP) QMR-UMC CLIP (TYP) TYPICAL LAYOUT NTS QMR-RL14 (TYP) QMR-UEC CLIP (TYP) QMR-UEC CLIP (TYP) -iiiiir- 0 * , — — — -I /Vo S "4j 9 4� I. - a WK&L m 04 CL dc m IEo C=) u CL S - 2 #10 THWN-2 (3 CONDUCTOR) 3/4" EMT, FMC, FOR EXTERIOR APPLICATION USE PVC OR LFMC/LFNMC CONDUIT #10 THWN-2 (3 CONDUCTOR) 3/4" EMT, FMC, FOR EXTERIOR LOCKABLE FUSED APPI-CATION USE PVC OR PV AC DISCONNECT LFMC/LFNMC CONDUIT 240V 2-POLE #10 THWN-2 (3 CONDUCTOR) -4�30A 30A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR APPLCATION USE PVC I OR LFMC CONDUIT 1-21 11-1 METER 0 #6 THWN-2 30 AC PANEL 150 AMP/240V Fa SPACE SPACE GROUND NOTE: ALL INVERTERS ARE EQUIPPED W/ INTERNAL RAPID SHUTDOWN SYSTEM PER NEC 690.12 ENPHASE Q CABLE Q-12-10-240 (TYP) ENPHASE IQ COMBINER PLUS W/ (2) 20 AMP BREAKER SOtADECK COMBINER BOX 60OV/ NON —FUSED OR SOLTECTION RESIDENTIAL TRANSITION BOX GEC BOND AT RACKING SYSTEM — (SEE NOTE #2) ENPHASE Q CABLE 0-12-10-240 (TYP) mi [ 7 - AC LDC NO, 1 kilo m NO, 1 NO. 12 AC AC I DCDC MISSION SOLAR: MSE320SR8T W1 ENPHASE IQ7-60-2-US INVERTER RL14 (TYP) NOTE: ALL STRINGS TO HAVE TERMINATORS & SEALING CAPS INSTALLED PER MANUFACTURER'S SPECIFICATIONS ENPHASE Q CABLE MISSION SOLAR: MSE320SR8T Q-12-10-2401 W/ ENPHASE IQ7-60-2-US (TYP) INVERTER ZZ 7 m m C-4 m S-3 MODULE SPECIFICATION MODULE MAKE MISSION SOLAR MODULE MODEL MSE320SR8T FSEC CERTIFICATION PMAX (STC) 320 W VOC (STC) 40.80 V VMPP (STC) 34.22 V ISC (STC) 10.03 A IMPP (STC) 9.35 A NOCT 46 C TC [Sc 0:039 %/C TC VOC -0.280 %/C` TC PMPP -0.377 %/C OPERATING TEMP. -40-+85 C SAFETY LABELS AND MARKINGS GENERAL NOTES: 1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE PRE -APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH EQUIPMENT FOR INFORMATIONAL PURPOSES. 2, LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. 3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV RESISTANT OUTDOOR -RATED LAMINATED VINYL IN ACCORDANCE WITH ANSI Z535.4-2011. SAFETY LABELS AND MARKINGS LEGEND A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT POCC. MAIN SERVICE DISCONNECT MARKING A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT CURRENT (DC) PHOTOVOLTAIC SYSTEMS, THE LABEL SHALL BE RED WITH WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. CIRCUIT DISCONNECTING MEANS MARKING A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: "PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. INVERTER SPECIFICATION INVERTER MAKE ENPHASE INVERTER MODEL IQ7-60-2-0 MAX AC POWER OUTPUT 250 VA MAX. INPUT VOLTAGE 48 V NOM. DC VOLTAGE @240V 240 V NOM. AC VOLTAGE 16-48 V MAX. CONTINUOUS OUTPUT CURRENT 1.00 A MAX. DC CURRENT t5,0 A. MAX. DC POWER (STC) 350 W CEC EFFICIENCY 97 % N AN EMERGENCY CONTACT US SOLAR 1 813-434-0284 SOLAR PHOTOVOLTAIC SYSTEM Ai -WARNING- AUTHORIZED PERSONNEL ONLY RATED AC CURRENT: 28.8A NOMINAL AC VOLTAGE: 240V LOCATION: MAIN PV PANEL PHOTOVOLTAIC DISCONNECT -WARNING- ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION, LOCATION: AC DISCONNECT(S) NOTES: 1. ALI ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION, 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690,4(D). 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE ITEMS IDENTIFIED IN NOTE 1. 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING -ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION OR EQUIVALENT. 6. PER NEC 705,10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY; WHICH EVER IS LESS. NEC 310.15 (B)(2) 10,ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. 12, PV ARRAY INTERCONNECTION TO BE MADE WITH BACK -FEED BREAKER, 13. GFI BUILT IN TO ALL INVERTERS. SAFETY LABELS Ai -WARNING- ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED AUTHORIZED PERSONNEL ONLY LOCATION: DISCONNECTS, INVERTERS, JUNCTION BOXES, OTHER ENCLOSES HOLDING DC CONDUCTORS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO � THE 'OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY env.° ygv`s. * ®. No$479 �?A C-> V U) N2 Z rn O C o JAM t3 o�¢ H C, wow 1 w U = H N Z Z"' w w z � o CH'1 CL Z =51 w 0 z PERC 60 Electrical Parameters at Standard Test Ccinditions (STC) Power Output Pmax WP 315 320 325 Tolerance 0-+3% 0-+3% G-+3%. Open Circuit Voltage Voc v 40.44 40.80 41-14 Rated Voltage VmP V 34.04 34.22 34.62 mv ? WIN" it ay..,', '114 WON R" lR40 't'wl 1. 0, V P � Temperature Coefficient of Pmax -0.377% / 'C Temperature Coefficient of Isc 0.039% /'C Operating Temperature Range -40°C (-40'F) to +85'C (I 85'F) ci 1 "14.11 g 'o N c % Fire Safety Classification Type 1, Class C Hall Safety Impact Velocity 25mm at 23 m1s OF; 1 11 w` "BI Cell Orientation 60 cells (6x10), 5 busbar Weight 20 k9 (441b) M 10 ;? 8 4 2 GLAS'F� LEADING 315,-3'2SjW 61215 - 61730 - 61701 - Salt mist UL 1703 listed -&-, CEC 40 ulmin WSE32GSRU320WP, 60 CELL OAR MODULE CURRENT - VOLTAGE CURVE .................. ........ . ....................... . Voltage M Current -voltage characteristics with dependence on irradiance and module temperature BASIC DES(GN (UNITS- imm) IMMIT =-� INPUT DATA (DC) 107-60-2-US 107PLUS-72-2-US . . . . . . . . . . Module compatibility 60-cell PV modules only 60-cell and 72-cell PVmodules ft Peak power tracking voltage 27V-37V 27V-45V Maximum continuous output current 1.0 A 1,15 A 1.21 A 1-39 A Extended frequency range 47 - 68 Hz 47 - 68 Hz Maximum units per 20 A (L-L) branch circuit, 16 (240 VAC) 13 (2.40 VAC) 13 (208 VAC) 11 (208 VAG) AC port backfeed current 0 A 0 A Frame Anodized aluminum alloy Environmental category/ UV exposure rating NEMA Type 6 I J TA I J-Box Protection class IP67 with 3 bypass -diodes tesNO Connector MC4 Compatible Mission Solar Energy reserves the right to make specification changes without notice D`Xks A, 1., 11`2 P-El"IS Oil ftW 4;M,020 Front View Back View MISSION SOLAR ENERGY Mission Solar Energy 18303 S. New 8—lm.ls Ave., San Antonio, Ts— 78235 lnfo@missionsolir.com I wvw.missionsolar.com Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy - CA Rule 21 (UL 1741 -SA) UL 62109-1, UL1741/]EEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107A-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No, enforced DC/AC ratio. See the compatibility calculator at 2. Nomirlai voltage range can be extended beyond nominal if required by the utility. 1 Limits may vary. Refer to local requirements to define the number of microinverters per branch in you, area. To learn more about Enphase offerings, visit enphase.corn ENPHASE. Mi ' Fl.nner,y All rights rese-ved AH ane the propoi t., of p 20 C E • NO 8 79 AL 0% X, A A44L LLj �'c Z DWG. NO. S-5 Enphase Q Cable Accessories Q Commercial Aggregator Q-BA-3-3P-95 (threejlhaisej,. Combines up to three; single-phase microinverter branches into a three- phase home rum Prolectwith.roaximium 40 A, I -pole OCPD.. WR Homeru n conductor size range #12 to 04 AWG M EV 00WR "t4*00NNOW Nq-MM§WXWL:'JW'42 k,` TnWf, Ternperature range 40'C to +55'C ( 40'F to +122'F) CONDUCTOR SPECIFICATIONS Flame test rating FT4 ilaotq, " R . ... 01WO fift, Stets wr, HIM "11,�IMWI IF -n,41,0 Conductortype THHN/THWN-2dry/wet 01 R IIn Mo ad 11 W A Lamm 0 CABLE TYPES f ORDERING OPTIONS _ig.Wi6mber Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box 0,12-17-240 277 VAC 2.0 m (6,5 ft) Landscape (60-cell) 240 tNPHASE Q CABLE ACCESSORIES Name Model Number Description rield-wileable connector (male'} O-CONN-10M Make connections from any Q Aggregator open connector Mbka If N Cable Crip Q-CLIP-100 Used to fasten cabling to the tacking or to secure looped cabling OAggregator sealing caps {male) O-BA-CAP-10 Sealing cap for unused aggregator connections sm 01 tom ;ie 4y ti o Terminator 0 TERM-10 Terminator cap for unused cable ends OWN gr Replacement DC Adaptor (UTX) Q-DCG-5 DC adaptor to UTX (max voltage 100 VDC) TERMINATOR µ u SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends, sold in packs often i and cable connections (Q-TERM-10) (Q BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL CABLE CLIP Plan to use at least one per Used to fasten cabling tothe tacking installation, sold in packs often or to secure looped cabling, sold in (Q-DISC-10) packs often (Q-CLIP-100) To learn more about Enphase offerings, visit enphase.com 0 2018 Enphase Enerily. Ali righ. in, m­er�,ed. Ai I terierna rk.,3 C., 1. !.zi rr.per tj F..r on ise. F. ntargy, inc. --ENPHASE. Enphase IQ Combiner 3 PiELNUMBER Circuit Breakers Supports Eaton OR210, BR215, BR22% 811230, BR240, BR250, and BR260eirctilt breakers, BRK-10A-2-2240 Circuit breaker, 2 pole, 10A, Eaton BR210 RRK-1 ' 5A-2-240 Circuit breaker, 2 pole, 15A, Eaton 811215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 ,E, L 10' WE1111 i XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in 10 Combiner 3 (required for EPLC-01) 1 ,12 2"� 2�2 ""'"22r. ELECTRICAL SPECIFICATIONS System voltage 1201240 VAC, 60 Hz r Etrtoh,m A c. JJ Max, continuous current rating (output to grid) 65A max "W" e T Branch circuits (solar end/or storage) 11/11., jj Up to four 2-pole Eaton BR serifs Distributed Generation (tit;) breakers only (not included) comet:, t'A '#hpuf` in g xP r Z - br.,:WWcurt breaker rating (input) 80A of distributedgeraration 90A with IQ Envoy breaker included L±= Aotqnn�,CT LL 2 MECHANICAL DATA -------- Weight TS kg (16,51bs) ... . . . .......... P,'Cl C 'Ah Whl'Tom# Coding Natureconvection, plus heat shield .... ..... .. UE closure,erivr6hin y a eirtio ,r '-------_____---.............. Wis!"e 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (im Included) COMPLIANCE To learn more about Enphase offerings, visit Mha4exmi 2;) ;. kA:rgserved.od enark sorscryce ri@ms are lle EN PHASE, W1,11 The NanoMount Advantage ,4 The fastest roof attachment in solar Versatile mounting options including direct -to -decking Eliminates the need to lift shingles and prevents damage to shingle High -Velocity Hurricane Zone Approved ® Passed TA S 100 (a) Wind -Driven Rain Test All materials are compatible with roof shingles Alignme enable easy I Structural U'UIck Mount PV" ENGINUITY RESPECT THE ROOF Ingenuity in Engineering Rail Spans for Quick Mount PV QRail Light System Mean Roof Height: 0<h:515ft Panel Orientation: Portrait Table 3 Roof Angle: 7 < 0 :5 27 degrees Exposure Category: C Roof Ground Wind Speed (mph) Wind Zone Snow Load 100 110 115 120 130 140 150 160 170 175 180 190 Zone 0 10 20 . . . . . . . . . . A 45 45 45 US 45 45 76, j1,1 45 45 45 45 45 45 48 44 30 40 1 50 41 41 41 41 41 41 41 41 41 41 41 41 60 38 38 38 38 38 38 38 38 38 38 1 38 38 70 35 35 35 35 35 35 35 35 35 35 35 35 80 33 33 33 33 33 33 33 33 33 33 33 33 90 31 31 31 31 31 31 31 31 31 31 31 31 0 48 45 43 42 40 10 g O 48 45 43 42 40 Zone 20 N 45 45 45 45 5 45 45 48 45 43 42 1 40 30 48 45 45 45 43 43 42 42 40 40 40 2 50 41 41 41 41 41 41 41 41 41 41 41 40 60 38 38 38 38 38 38 38 38 38 38 38 38 70 35 35 35 35 35 35 35 35 35 35 35 35 80 33 33 33 33 33 33 33 33 33 33 33 1 33 90 31 31 31 31 31 31 31 31 31 31 31 31 0 VMS,, IM 2111/ 48 44 41 38 36 35 34 32 10 WON 48 44 41 38 36 35 34 32 20 48 44 41 38 36 35 34 32 30 Lim! 48 44 41 38 36 35 1 34 32 Zone 40 45 45 45 45 45 44 41 38 36 35 34 32 3 50 41 41 41 41 41 41 41 38 36 35 34 32 60 38 38 38 38 38 38 38 38 36 35 34 32 70 35 35 35 35 35 35 35 35 35 35 34 32_ 80 33 33 33 33 33 33 33 33 33L+ 33 33 32 90 31 31 31 31 31 31 31 31 31 31 Notes: 1. Tables are based on critical rail span for load combinations as specified in chapter 2 of the ASCE 7-10 and allowable design loads per the 2015 Aluminum Design Manual. 2. Panels are assumed to be in portrait orientation with a maximum length of 67.5" 959 Larchmont Court, Aurora, IL 60504 3/4/2019 630-219-1997 (P) www.structuralenginuityinc.com C3 - -T- - I I - - - ---