Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
38103 Market Square Dr
PARTITION LEGEND r__=___=7I EXI5TIN67 PARTITION TO BE DEMOLISHED EXI5TIN6 PARTITION TO REMAIN DEMOLITION GENERAL NOTES I. ALL WORK SHALL BE DONE IN COMPLIANCE WITH ALL APPLICABLE BUILDING COVE-5 AND IN COMPLIANCE WITH THE AMERICANS WITH DISABILIT IES ACT AD AGGE551BILITY GUIDE I 5 FOR ( A) L NE BUILDINGS AND FACILITIES. CAUTION 5 HEREBY 61 N THAT LI I VE WORK SHALL BE PERFORMED 50 AS TO CAUSE THE LEAST P0551BLE INCONVENIENCE OR DISTURBANCE TO BUILDIN6 OCCUPANTS. 2. ALL WORK SHALL BE DONE IN COMPLIANCE WITH THE PLANS AND SPECIFICATIONS OF THE BASE BUILDING. 3. CONTRACTOR SHALL INFILL ALL VOIDS IN FLOOR LEFT BY ABANDONED ELECTRICAL/DATA BOXES.. 4. PLANS WERE DEVELOPED FROM INFORMATION SUPPLIEDBY OW NER AND FROM EXISTING CONDITIONS OBSERVED. CONTRACTOR SHALL VERIF Y AND 8E RESPONSIBLE FOR ALL FIE LD DIMEN51ONS AND CONDITIONS SHOWN TO BE 15 IN6 AND 5 10 WN X T A HALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE SUBMITTALF B A E O ID AND PROGE DING WITH THE WORK. COMMENCEMENT OF CONSTRUCTION IMPLIES THAT ALL CONDITIONS, UNLESS PREVIOUSLY DETERMINED AND DOCUMENTED OTHERWISE, ARE IN FACT AS DE50ROED ON THESE PLANS AND SPECIFICATIONS AND ACCEPTED AS SUCH BY CONTRACTOR. 5. CONTRACTOR TO BE RESPONSIBLE FOR PAYING REQUIRED FEE5, 5EGURIN6 REQUIRED PERMITS AND DEMOLISHING AND COMPLETELY REMOVING FROM THE SITE ALL UNNECESSARY EXISTING CONSTRUCTION DEBRIS AND OTHER MATERIALS SHOWN ON THE DRAWINGS TO BE REMOVED. 6. IF ANY ADDITIONAL WORK OR CHANCES WILL ADVERSELY AFFECT THE COMPLETION SCHEDULE, THE CONTRACTOR SHALL ADVISE THE OWNER AND ARCHITECT IN WRITING IMMEDIATELY. 'T. THE OWNERS WRITTEN AUTHORIZATION MUST BE OBTAINED PRIOR TO THE ORDERING OF ANY MATERIAL, AWARDING OF ANY CONTRACTS, OR THE EXECUTION OF ANY WORK INVOLVING EXTRA COST ABOVE THE CONTRACT SUM. 6. WHEN INSTALLATION OF NEW WORK REQUIRES THE SHUTDOWN OF EXI5TIN6 OPERATING SYSTEMS, THE CONNECTION OF THE NEW WORK SHALL BE PERFORMED ONLY AFTER GIVING REASONABLE NOTICE AND OBTAININ6 APPROVAL FROM THE OWNER. Q. GENERAL CONTRACTOR SHALL MAINTAIN BUILDIN6 SECURITY, FIRE ALARM, AND FIRE PROTECTION AT ALL TIMES DURING PERFORMANCE OF WORK. 10. CONTRACTOR TO INSPECT ALL FIRE RATED PARTITIONS AND SEAL PENETRATIONS AS NEEDED TO A55URE FIRE RATING. II. DRAWIN65 ARE NOT TO BE SCALED FOR INFORMATION. 12. WHEN PERFORMING CONSTRUCTION IN OCCUPIED TENANT SPACES AS PART OF AN EXPANSION PROJECT, EACH OCCUPIED SPACE AFFECTED BY THE CONSTRUCTION SHALL BE THOROUGHLY GLEANED IMMEDIATELY FOLLOWING CONSTRUCTION COMPLETION, RE6ARDLESS OF PROGRE55 OR SCHEDULE OF OVERALL PROJECT. 15. PATCH AND REPAIR ALL GYPSUM BOARD WALL SURFACES SHOWN TO REMAIN AND AFFECTED BY NEW CONSTRUCTION WITH MATERIALS AND METHODS TO MATCH EXISTING CONDITIONS AND PROVIDE A UNIFORM APPEARANCE. PREPARE GYPSUM BOARD TO RECEIVE NEW WALL FINISHES (TO GEILIN6 HEIGHT) AS SPECIFIED, 14. FIN15H EXI5TIN6 COLUMNS AND ANY OTHER BASE BUILDING SURFACES AS REQUIRED TO MATCH ADJACENT OR ABUTTING SURFACES UNLESS OTHERWISE NOTED. 15. REMOVE EXI5TIN6 FLOOR FIN15H MATERIALS ONLY AS NOTED ON DEMOLITION PLAN. CONTRACTOR TO INSPECT EXISTING FLOOR SURFACE. PATCH, REPAIR AND FLOAT ALL CONCRETE FLOOR SURFACES AS REQUIRED (TO MEET TOLERANCE REQUIREMENTS OF A.G.I. STANDARDS FOR CLASS "A" OFFICE BUILDINGS - 1/4" IN 10 FEET) TO ACHIEVE A LEVEL SURFACE FOR INSTALLATION OF NEW FLOOR FINISH MATERIALS. FLOOR AREAS NOT LEVEL SHOULD BE BROUGHT TO THE ATTENTION OF THE BUILDING MANAGEMENT/ARCHITECT PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 16. GENERAL CONTRACTOR SHALL COORDINATE FLOOR PENETRATIONS WITH STRUCTURAL. SYSTEM TO AVOID DAMAGE TO SUCH ITEMS A5, BUT NOT LIMITED TO I POST -TENSIONED GABLES, ANCHORS, AND STEEL REINFORCEMENTS. BUILDING DESCRIPTION: STORIES: I SPRINKLED: YES YEAR BUILT: I gi4 PARCEL ID: 02-26-21-0010-039400-0030 PROJECT SCOPE: INTERIOR RENOVATION OF AN EXISTING MEDICAL OFFICE SUITE, LOCATED AT EXISTING MEDICAL OFFICE FAG I LI TY. FIRE PROTECTION SYSTEM PLANS TO BE DESIGNED BY A LICENSED FIRE PROTECTION CONTRACTOR AND SUBMITTED UNDER SEPARATE PERMIT. OCCUPANCY CLA551E1C.ATION: EXI5TINO FBC - BUILDING, CHAPTER 5 SECTION 501: BU51 NE55/MED I GAL OFFICE USE - GROUP 15, (SPRINKLED) CONSTRUCTION TYPE: 11-5 (SPRINKLED) CLASVrIGATION Of= WORK: EX15TINO F-ACIL17Y ALTERATION LEVEL 2 AS DESCRIBED IN THE FLORIDA BUILDING CODE, EXISTING BUILDINGS, SECTION 605 500' MAX. TRAVEL DISTANCE ALLOWED FOR SPRINKLED BUILDINGS. 50' MAX. DEAD END CORRIDORS, 100' MAX. TRAVEL DISTANCE ALLOWED FOR SINGLE EXIT 5PRINKLED SPACES AND WITH TOTAL OCCUPANCY LESS THAN 441. SINGLE EXIT ALLOWED PER FBG TABLE 1006.2.1 OCCUPANCY LOAD: SUITE 38135 Room Number Classification Square Footage Occupancy Reception Waiting Area 101 Business Assembly 281 19 Balance of Space Business 2951 20 TOTAL ALL 1 1 3232 39 Business Assembly spaces calculated at 15 sf per person Business spaces calculated at 150 sf per person LIFE SAI=ETV LEGEND FEC a WALL MOUNTED 2A-IOBC FIRE EXTINGU15HER BUILDING STANDARD GEILIN6 MOUNTED COMMON AREA D EXIT 1 T CONNECTED TO OR e G LE E L 6H G E LOCAL EMERGENCY CIRCUIT, SEE ENGINEERING DRAWINGS FOR SPECIFICATION opt BUILDING STANDARD DIRECTIONAL CEILING MOUNTED COMMON AREA LED EXIT LIGHT CONNECTED TO EMERGENCY CIRCUIT, SEE ENGINEERING DRAWIN65 FOR SPECIFICATION BUILDING STANDARD WALL MOUNTED COMBO EXIT 516N WITH DUAL LAMP EMERGENCY L 16HT FIXTURE WITH BATTERY BACK-UP BUILDING STANDARD GEILIN6 MOUNTED COMBO EXIT SIGN WITH DUAL LAMP EMERGE CY L16HT FIXTURE WITH BATTERY BACK-UP P CLG CEILING MOUNTED ADA APPROVED FIRE ALARM AUDIB STROBE NGINEERIN6 LE/ SEE E DRAWINGS DETAILS — — EXIT ACCESS TRAVEL DISTANCE OVERALL DIAGONAL DISTANCE GORES 4 ORDINANCES The following construction documents adhere to the Florida Building Code as well as the other codes and regulations In effect in the applicable city or country government and all other codes referenced in the Florida Building Coate and tabulated in chapter 35. APPLIICABLE CODES Code Volume I Year FLORIDA BUILDING CODE Florida Building Code Building 7" Edition 2020 Florida Building Crude Existing Building 7m Edition 2020 Florida Building Code Accessibility 7h Edition 2020 Florida Building Code Energy Conservation 7fft Edition 2020 Florida Building Code Fuel Gas 7- iEdition 2020 Florida Building Code Mechanical 7tft Edition 2020 Florida Building Code Plumbing 71h Edition 2020 OTHER CODE'S WPA 1 — The Florida Specific Edition Fire Cade 2018 Edition NFPA 10 Standard for Portable Fire Extinguishers 2018 Edition WPA 13 Standard for the Installation of Sprinkler Systems 2016 Edition NFPA 14 Standard for the Installation of Standpipe &Hose sterns 2016 Edition NFPA 70 National Electric Code 2017 Edition NFPA 72 National Fire Alarm and Si nalirs Code 2016 Edition NFPA 80 Standard fox Fire Doors & Other Open ing Protectives 2016 Edition NFPA 90A Standard for the installation of A/C & Ventilating Systems 2018 Edition WPA 101 —Florida Specific Edition Life Safety Code 2018 & 7u, Edition 2020** Florida Fire PreVenttcirl Code 71" Edition 2020 Adopted by the State Fire Marshal " Utilizing the Florida -specific sections of the 7m Edition 2020 Florida Fire Prevention Code All interior wall and ceiling finishes shall meet or exceed the requirements of section 803 of the r edition 2020 FBC_ 5U I TE 58155 WORK AREA (HATCHED) 5,252 USF BUILDING EXTERIOR X/ f / / t if r i / r / f / r / j� f / I 'x / ;I- //5T1 GkO 8" G FIR / r IR ED/ P 41 XI6T r / EXISTING- BE' NE A / OCR() � � PH , EXAM R / Iv // II0p�p ANC BACK B�"(PC 'NO 'W K TO 91. . s EAT. CLE;'i4 I �. �I HATCHED AREAS/ I , rE 54'-9" TATION ►12 j i EXAMJjLN SWP nl LOS EXAM 7 I I14- R" 1. 3 r AREA j OFFICE I lF1221i _ ELE %; �►� %; _---= Gib' I / / / 1 EP I EXAM FRONT 1 CLE FRONT ---; I WORK RM. RAMIE I 1 RR; I I I tls 1 EXAM / / n4 f CORR r; �r�--i-�--►-- In----►---1 1213 r /� z Jlrzz r czZ / PTION -- -, EXIST. `---a /% p tuAITIIIK� Rt'I 55'-7" ' ---- / ------ A� EXIT#1 BUILDING OVERALL DIAGONAL EXTERIOR DIST, a W-0` DISTANCE BETWEEN EXIT 01 t EXIT "2 = 15'-3" 5U I LD I NO KE`1' FLAN � AND PRIMARY #'UNCTION AREA ND PATH COMPLIES WITH PART A, FLORIDA ACCESSIBILITY GORE N.T.S. NORTH FOR BUILDING CONSTRUCTION SECTION II-4.IAW. ZEPHYRHILLS, FLORIDA 33542 NORTH ( I WDA DESIGN GROUP INCORPORATED ARCHIT CTURE I SPACE PLANNING I E A CANNING INTERIORS 1 5057 TAMPA PALMS MLUD. WEST #1 6O TAMPA • FLORIDA . 334647 TELEPHONE 813-986-2800 ©. COPYRIGHT 2023 WDA DESIGN GROUP, INC. l� V torr'�' ' t 1 E IL V � ;Q; z � a Q V l IU V m .� p✓ m LL to T_ W . LU lu a LL CO N SHEET INDEX: A.01 COVER SHEET: NOTES, LEGENDS 8 DETAILS 4 LIFE -SAFETY PLAN A.02 DEMOLITION PLAIN 4 CEILING DEMO PLAN PROJ.NO: 54"1001 DR./REVIMD BY: EC -?I J IMB DATE: 11.20.25 REVISION DATES: SEAL: ok\CK C. G(/ 08 'o 0 ° ° �o ERICK G. 6ULKE N1 ARa45a6 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ERICK C. GULKE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. SHEET NAME: COVER 5HEET: NOTES/LEGENDS 4 LIFE SAFET r PLAN SHEET NUMBER: r� , BUILDING EXTERIOR EXISTING GROUP "B" EXISTING 1HR OCCUPANCY FIRE RATED / PUBLIC EXIT CORRIDOR ' � �NO VVORK TO EXISTING /', - ".Bt DONE AT GROUP'U" . HITCHED OCCUPANCY AREAS�- I� ___-_-_-_--_- f IIIj~ I yv EXISTING it j D3 GROUP .B" R R -� 2 L�p.JJ L OCCUPANCY/" I i D5 R - D8 'NO WORK TO Rr DI5 - BE DONE AT HATCHED. R i �\ AREAS Iz DI r------- D14'Iru�1 DII" D ---g I!A-1 na.I �D4D17 R D3 D4 I 2 I 1 I IR I BUILDING EXTERIOR 1:�)E1*-COL. I T I ON FLAN (�D SCALE: I /a 11 _ 11_0 11 NORTH KEYED DEMOLITION NOTES: Q DI RELOCATE EXI5TIN6 DOORS AND HARDWARE FROM DEMOLITION AS APPROPRIATE TO AREAS OF NEN CONSTRUCTION AS 5HONN ON CONSTRUCTION PLAN SHEET A.05. TOUGH -UP AND REFINISH ALL REUSED DOORS TO ACHIEVE "LIKE -NEW" APPEARANCE. ANY DOORS NOT REUSED ARE TO BE DISCARDED. D2 REMOVE EXISTING INTERIOR PARTITIONS AND ASSOCIATED ELECTRICAL/VOICE/DATA 4 SWITCH OUTLETS AS SHOWN ON PLAN. 05 EXISTING FLOOR FINISHES AND NALL BASE ARE TO REMAIN. PATCH FLOOR AND NALL BASE AT AREAS OF NEW CONSTRUCTION AND THOROUGHLY GLEAN ALL FLOORING AND NALL BASE. D4 REMOVE EXI5TIN6 MILLWORK AS 5HONN AND DISCARD. PATCH FLOORS AND HALLS 5HONN TO REMAIN. D5 CAREFULLY REMOVE NEW UPPER CABINETS AND SAVE FOR RELOCATION A5 5HONN ON CONSTRUCTION PLAN SHEET A.05. Db REMOVE EXI5TIN6 BASE CABINETS 4 SINK AND DISCARD. RELOCATE PREVIOUS SINK PLUMBING LINES TO NEW SINK LOCATION, SEE ENGINEERING DRAWINGS FOR DETAILS. D7 GUT OPENING IN EXI5TIN6 NALL TO ALLOW INSTALLATION OF NEW 5'-0" WIDE BUILDING STANDARD DOOR. (SEE CONSTRUCTION PLAN SHEET A.05). D8 REMOVE EXISTING CLOSET AND SHELVING AS 5HONN AND DISCARD. PATCH FLOORS AND NALL5 SHOWN TO REMAIN. Dq REMOVE EXISTING HATER CLOSET, SINK AND GRAB BARS. NEW TO BE INSTALLED AT LOCATIONS SHOWN ON CONSTRUCTION PLAN SHEET A.05. DIO REMOVE EXISTING DIAPER CHANGING UNIT AND D15CARD. PI REMOVE EXI5TIN6 FLOOR MOP SINK AND DISCARD. NEN TO BE INSTALLED AT EXISTING LOCATION. D12 REMOVE EXI5TIN6 IN5TA-HOT HATER HEATER 4 SHELF AND DISCARD. NEW IN5TA-HOT TO BE INSTALLED AT EXI5TIN6 LOCATION. P15 RELOCATE EXISTING OUTLET/OUTLETS AS SHOWN ON POKER -COMMUNICATIONS PLAN SHEET A.04. PATCH $ PREPARE NALL TO RECEIVE NEN FINISHES. D14 REMOVE EXI5TIN6 OUTLET/OUTLET5. PATCH AND PREPARE NALL TO RECEIVE NEW FINISHES. DI5 REMOVE AND RELOCATE EXISTING 5WITCH/5NITCHE5. PATCH AND PREPARE HALL TO RECEIVE NEW FINISHES. DIb REMOVE EXISTING SHELVING AND DISCARD. D17 EXI5TIN6 FLOOR OUTLETS TO BE REUSED AT NEN MILLWORK LON HALL. D18 REMOVE EXI5TIN6 FIRE EXTINGUISHER AND SAVE FOR RELOCATION. DIq REMOVE EXI5TIN6 DRINKING FOUNTAIN TO ALLOW NEW HI -LOW ADA COMPLIANT DRINKING TO BE INSTALLED AT THI5 LOCATION. D20 REMOVE EXI5TIN6 TRANSACTION TOP TO ALLOW FOR NEN STONE TOP. SAVE EXISTING 5LIDIN6 WINDOW TRACK FOR REUSE. V21 REMOVE EXI5TIN6 CHAIR RAIL AT NAITIN6 ROOM. PATCH AND PREPARE NALL5 TO RECEIVE NEW PAINT. D22 REMOVE EXISTING DOOR FRAME TO ALLOW FOR NEW FINISHED DRYWALL OPENING. P25 REMOVE EXI5TIN6 BASE CABINETS $ SINK AND DISCARD, REUSE PREVIOUS SINK PLUMBING LINES FOR NEW SINK AND MILLWORK, SEE EN61 NEERI NG DRAN I N65 FOR DETAILS. PARTITION LEGEND EXI5TING PARTITION TO BE DEMOLISHED EXI5TIN6 PARTITION TO REMAIN POWER -COMMUNICATIONS DEMO LEGEND I flM IV DUPLEX ELECTRICAL RECEPTACLE ll� GFI DUPLEX ELECTRICAL RECEPTACLE - GROUND FAULT (TI) , DUPLEX ELECTRICAL RECEPTACLE, MOUNTED AT A SPECIFIC HEIGHT ABOVE FINISH FLOOR (A.F.F.) Ll GUADRUPLEX ELECTRICAL RECEPTACLE zi VOICE AND/OR DATA OUTLET (SEE NOTE 5 BELON) VOICE AND/OR DATA OUTLET MOUNTED AT A SPECIFIC HEIGHT ABOVE FINISHED �144" FLOOR (A.F.F.) BLANK PLATE COAXIAL CABLE OUTLET L�J ELECTRICAL JUNCTION BOX t THERMOSTAT "R" - OUTLET TO BE RELOCATED OUTLET, SEE LEGEND ABOVE FOR SYMBOL DE516NATION AND POWER-COMMUNICATION5 PLAN SHEET A.04 FOR NEW LOCATION. GENERAL DEMOLITION NOTES: I. DEMOLISH EXISTING 6YP5UM BOARD PARTITIONS THROUGHOUT SPACE ONLY AS 5HOHN ON DEMOLITION PLAN (VERIFY EXTENT OF PARTITIONS IN FIELD). SAVE ALL DOORS, FRAMES AND HARDWARE WHICH SHALL BE RELOCATED THROUGHOUT NEW SPACE AS APPROPRIATE. PATCH AND REPAIR ALL AREAS AFFECTED BY DEMOLITION WITH MATERIALS AND METHODS TO MATCH EXI5TIN6 CONDITIONS, AND PROVIDE A UNIFORM APPEARANCE. 2. SAVE ANY EXISTING UPGRADED TENANT FIXTURES (E.6., MILLWORK, INTERIOR CLASS, APPLIANCES, ETC.) AT AREAS OF DEMOLITION FOR RELOCATION/REU5E PER CONSTRUCTION PLAN/NOTES; RETURN ANY FIXTURES NOT REUSED TO BUILDIN6 MANAGEMENT FOR FUTURE STOCK. 5. ALL EXI5TIN6 FLOOR FINISH AND WALL FINISH MATERIALS TO BE REMOVED UNLESS OTHERWISE NOTED. PATCH AND REPAIR ALL CONCRETE FLOOR SURFACES AND GYP. BOARD WALL SURFACES TO RECEIVE NEW FIN15H MATERIALS. 4. ABANDONED WIRING IN CONDUIT RUNS ABOVE CEILING ARE TO BE DEMOLISHED/REMOVED BACK TO TERMINATION POINTS AT BREAKER PANEL TO FREE UP PANEL SPACE FOR FUTURE CONSTRUCTION. 5. REUSE ANY EXI5TIN6 DOORS AND HARDWARE REMOVED DURIN6 DEMOLITION AS APPROPRIATE PER NEW CONSTRUCTION. (VERIFY EXISTING DOOR 5HIN6B AND HARDWARE IN FIELD). TOUGH -UP AND REFINISH ALL REUSED DOORS AS REQUIRED TO ACHIEVE "AS-NEH" APPEARANCE. 6. ABANDONED WIRING IN CONDUIT ABOVE GEILIN6 15 TO BE DEMOLI5HED/REMOVED BACK TO TERMINATION POINTS AT BREAKER PANEL TO FREE UP PANEL SPACE FOR FUTURE CONSTRUCTION. '1. EXI5TIN6 OUTLETS NOT SHOWN ON PLAN ARE TO REMAIN. 8. CONTRACTOR TO VERIFY THAT ANY EXI5TIN6 ELECTRICAL OUTLETS AND SWITCHES SHOWN TO REMAIN ARE IN PROPER HORKINCP ORDER. CEILING DEMOLITION LEC END BUILDING STANDARD 2' x 4' CEILING GRID 4 ACOUSTICAL CEILING TILE TO BE REMOVED r------I C 2' x 4' RECE55ED FLUORESCENT LIGHT FIXTURE WITH ACRYLIC LENS C i 2' x 2' RECESSED FLUORESCENT LIGHT FIXTURE WITH ACRYLIC LENS L--J rf \ l`� J SUSPENDED PROCEDURE LIGHT FIXTURE TO BE RELOCATED 0 RECESSED DOWNLI6HT SINGLE POLE SWITCH s THREE WAY SWITCH Y D DIMMER SNITCH ITS THERMOSTAT, SEE ENGINEERING DRAHING5 FOR EXACT LOCATION AND DETAILS EFJ EXHAUST FAN TO BE REMOVED BUILDING STANDARD MECHANICAL SUPPLY AIR DEVICE, SEE ENGINEERING DRANIN65 OR 0 FOR EXACT LOCATIONS AND DETAILS r-1 BUILDING STANDARD MECHANICAL RETURN AIR DEVICE, SEE ENGINEERING DRAWINGS LJ ORc FOR EXACT LOCATIONS AND DETAILS 0 FIRE SPRINKLER HEAD TO BE REPLACED, SEE FIRE PROTECTION PLAN BY LICEN5ED SPRINKLER CONTRACTOR FOR DETAILS ` SMOKE DETECTOR TO BE REMOVED AND RELOCATED GENERAL GEILIN6 DEMOLITION NOTES: I. EXI5TIN6 BUILDING STANDARD GEILIN6 &RID AND SUSPENSION SYSTEM TO REMAIN UNLE55 NOTED OTHERWISE. EXI5TIN6 GEILIN6 TILE 15 TO BE REPLACED WITH BUILDING STANDARD WHERE NOTED ON PLAN AND AT AREAS WHERE M1551146 OR DAMAGED. GEILIN6 GRID SHALL BE PATCHED, REPAIRED AND REPAINTED AS REQUIRED AT AREAS OF DEMOLITION, STRUCTURAL GEILIN6 6RID AND MEMBERS SHALL NOT BE CUT OR OTHERWISE DAMAGED; ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IF EXI5TIN6 CONDITIONS PREVENT LOCATION OF 2 X 4 LAY -IN FIXTURES PER PLAN). 2. ABANDONED WIRING IN CONDUIT RUNS ABOVE GEILIN6 ARE TO BE DEMOLI5HED/REMOVED BACK TO TERMINATION POINTS AT BREAKER PANEL TO FREE UP PANEL SPACE FOR FUTURE CONSTRUCTION. 5. SMOKE DETECTION DEVICES AND FIRE ALARM ENUNCIATORS SHALL BE PROVIDED BY GENERAL CONTRACTOR AS REQUIRED BY CODE. VERIFY IN FIELD WITH BUILDING OWNER'S REPRESENTATIVE ANY DEVICES TO BE USED AND PROCEDURES TO CONNECT TO BASE BUILDING FIRE ALARM SYSTEM; 6.C. TO COORDINATE WITH FIRE PROTECTION VENDOR TO PROVIDE DOCUMENTS FOR EXACT LOCATION OF DEVICES 4 WIRING REQUIREMENTS. 4. ANY AND ALL CHANGES, ADDITIONS, RELOCATIONS, IMPROVEMENTS AND/OR MODIFICATIONS TO THE FIRE SPRINKLER SYSTEM NECE551TATED BY THE WORK IN TH15 PERMIT MUST BE DONE AS PER NFPA-15 2016 EDITION BY A LICENSED FIRE SPRINKLER CONTRACTOR WITH A SEPARATE PERMIT AND PLANS. INSTALLING CONTRACTOR SHALL BE A LICENSED SPRINKLER CONTRACTOR RE615TERED IN THE STATE OF FLORIDA. 5. ALL EXI5TIN6 HVAC DIFFUSERS AND TRIM SHALL BE GLEANED; REPAIR AND REPAINT DAMAGED EQUIPMENT AS NECESSARY. 6. ANY AND ALL CHANGES, ADDITIONS, RELOCATIONS, IMPROVEMENTS AND/OR MODIFICATIONS TO THE FIRE ALARM SYSTEM NECESSITATED BY THE WORK IN THI5 PERMIT MUST BE DONE A5 PER NFPA-172 2016 EDITION BY A LICENSED FIRE ALARM CONTRACTOR WITH A SEPARATE PERMIT AND PLANS. IN5TALLIN6 CONTRACTOR SHALL BE A LICENSED FIRE ALARM CONTRACTOR RE615TERED IN THE STATE OF FLORIDA. BUILDING EXTERIOR GFILING DEMOLITION PLAN ON NORTH KEYED CEILING DEMOLITION NOTES:Q RI REMOVE ALL EXISTING 2x2, 2x4 AND CAN LIGHTS THROUGHOUT AND DISCARD. NEW LED BUILDING STANDARD LIGHT FIXTURES ARE TO BE INSTALLED AS 5HONN ON REFLECTED GEILIN6 PLAN SHEET A.04. R2 CAREFULLY REMOVE EXI5TIN6 PULL -DOWN PROCEDURE LIGHT FIXTURE AND SAVE FOR RELOCATION ALONG WITH EXISTING L16HT FIXTURE STRUCTURAL SUPPORT PER ENGINEERING DRANIN05. R5 REMOVE AND RELOCATE EXISTING MECHANICAL DEVICE AS SHOWN ON MECHANICAL DRAWINGS. R4 RELOCATE EXISTING LIGHT SWITCH AS SHOWN ON REFLECTED CEILING PLAN SHEET A.04. R5 REMOVE EXI5TIN6 SNITCH, LIGHT SNITCHING TO BE RE -WORKED AS 5HONN ON REFLECTED CEILING PLAN SHEET A.04 VENDOR ENGINEERING DRANI NG5. R6 REMOVE EXI5TIN6 SPRINKLER HEAD AND INSTALL NEW HEAD AT NEW LOCATION AS 5HONN ON FIRE PROTECTION PLAN $ SPRINKLER DRAWINGS BY LICENSED SPRINKLER CONTRACTOR. R'T REMOVE EXISTING GEILIN6 GRID AND GEILIN6 TILE AT THIS ROOM TO ALLOW FOR NEW HEIGHT GEILIN6. SEE REFLECTED GEILIN6 PLAN AT SHEET A.04 FOR NEW GEILIN6 LAYOUT. R5 REMOVE EXISTING GEILIN6 GRID AND GEILIN6 TILE AT AREA SHOWN TO ALLOW GEILIN6 TO BE REWORKED PER NEW CONSTRUCTION AS 5HONN ON REFLECTED GEILIN6 PLAN SHEET A.04. Rq REMOVE EXI5TIN6 CURTAIN TRACK AND DISCARD. RIO EXI5TIN6 X-RAY MACHINE TRACK TO REMAIN AND BE PAINTED TO MATCH GEILIN6 TILE. (!I WDA DESIGN GROUP INCORPORATED ARCHITECTURE I SPACE PLANNING I INTERIORS 1 6067 TAMPA PALMS BLVD. WEST #1 SO TAMPA . FLORIDA . 33547 TELEPHDNE a 13-986-26o0 © COPYRIGHT 2023 WDA DESIGN GROUP. INC. ^_V l� lu +f- z o E- W Z li z z ' V ILI v LU > �} lu Lu O O 1.1 O V th o +-� T_ CIL a IL a m N SHEET INDEX: A.01 COVER SHEET: NOTES, LEGENDS 4 'DETAILS 6 LIFE -SAFETY PLAN A.02 DEMOLITION PLAN 4 CEILING DEMO PLAN PROJ.NO: 54'7001 DR./REVIEWED BY: EG/JW/MB DATE: 11.20.25 REVISION DATES: ARg45g6 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ERICK C. GULKE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. SHEET NAME: DEMOLITION PLAN 4 GE I L I NC DEMO PLAN SHEET NUMBER: A. PARTITION LEC END EXISTING PARTITION TO BE DEMOLISHED EXISTING PARTITION TO REMAIN NEW BUILDING STANDARD SOUND INSULATED PARTITION: 3-5/5" METAL STUDS (25MEx) 24"O.C. WITH 5/6" GYP, BOARD EACH SIDE EXTENDED OA a TO 6" ABOVE SUSPENDED CEILING, ►NFILL W/3-1/2" THICK SOUND BATT INSULATION. LAY R-Iq (69 POLY -WRAPPED INSULATION ON TOP OF CEILING TILE 2'-0" ON EACH SIDE OF PARTITION (SEE WALL SECTION A SHEET A.01). VERIFY WALL THICKNESS IN FIELD CONTRACTOR SHALL VERIFY HEIGHT OF STEEL STUDS REQUIRED AND CONFIRM THAT THEY MEET THE MAXIMUM HEIGHT REOUIREMENT5 AS SPECIFIED IN THE STEEL STUD MANUFACTURERS HEIGHT LIMITATION TABLES. DOOR SCHEDULE UA EXISTING 4'-0" WIDE x 6'-5" HIGH BUILDING STANDARD TEMPERED 6LA5S STOREFRONT DOOR, PUSH-PULL HARDWARE, LOCKSET AND CLOSER TO REMAIN. OEXISTING 4'-0" WIDE x 6'-6" HI6H BUILDING STANDARD STAINED SOLID GORE DOOR WITH H.M. FRAME, LEVER SET HARDWARE AND CLOSER. OEXISTING 5'-0" WIDE x V-5" HIGH BUILDING STANDARD STAINED SOLID GORE DOOR WITH H.M. FRAME AND LEVER SET HARDWARE. OD EXISTING 5'-0" WIDE x 6'-6" HIGH BUILDING STANDARD STAINED 50LIP CORE DOOR WITH H.M. FRAME, LEVER SET HARDWARE AND KEYED LOCK5ET. OE EXISTING 5'-0" WIDE x 6'-6" HIGH BUILDING, STANDARD STAINED 50LID GORE DOOR WITH H.M. FRAME, LEVER SET HARDWARE, PRIVACY LOCKSET AND CLOSER. �F EXI5TIN6 5'-0" WIDE x 6'-6" HIGH BUILDING STANDARD STAINED 50LIP GORE DOOR WITH H.M. FRAME, LEVER SET HARDWARE, KEYED LOCKSET AND CLOSER OEXISTING 5'-0" WIDE x W-5" HIGH BUILDING STANDARD STAINED SOLID GORE DOOR WITH H.M. FRAME, LEVER SET HARDWARE, CYPHER LOCK AND CLOSER OH NEW OR RELOCATED 5'-0" WIDE x 6-5" HIGH BUILDING STANDARD STAINED SOLID GORE DOOR WITH H.M. FRAME AND LEVER SET HARDWARE. OJ EXI5TIN6 5'-0" WIDE x 6'-6" HIGH BUILDING STANDARD STAINED SOLID GORE DOOR WITH H.M. FRAME, LEVER SET HARDWARE, LOCKSET AND CLOSER. NOTES: 1) ALL LOCKING DOORS TO ALLOW FREE ACCESS IN PATH OF EGRESS AT ALL TIMES. 2) ALL HARDWARE TO BE LEVER SET AND MATCH IN FINISH. 5) ALL NEW DOOR OPENINGS TO BE LOCATED 6 INCHES FROM FACE OF PARTITION AT HINGE SIDE. 4) CONTRACTOR RESPONSIBLE FOR PROVIDING CONSTRUCTION GORES, CYLINDERS # BLANKS, AS REQUIRED, IN REUSED DOORS. 5) CONTRACTOR RESPONSIBLE FOR VERIFYING DOOR HEIGHT MATCHES EXI5TIN6. 6) ALL NEW DOORS TO MATCH EXI5TIN6 BUILDING, STANDARD SPECIES AND STAIN. ALL NEW STAINED DOORS ARE TO BE PRE -FINISHED IN FACTORY. NOTE: 6.0. TO CONFIRM ALL DOOR HEIGHTS IN FIELD PRIOR TO ORDERIN6 DOORS. BUILDING STANDARD DOOR SPEGIFIGATION5: TENANT INTERIOR DOORS= BUILDING STANDARD STAINED DOOR PRE -FINISHED IN FACTORY TO MATCH EXISTING SPECIES AND STAIN DOOR SIZE: 5'-0" WIDE (U.N.0) x T-O" HIGH x 1-5/4" THICK DOOR FRAME: 2" METAL 16 GAUGE COLD -ROLLED STEEL HOLLOW METAL FRAME, WITH (5) BLOC,. STD. HINGES MINIMUM. DOOR STOP: MATCH DOOR HARDWARE FINISH DOOR HARDWARE: LEVER 57YLE TO MATCH EXI5TIN6, FINISH: MATCH EXISTING UNDERSIDE lip OF DECK PROVIDE DIAGONAL BRAG I N6 TO STRUCTURE ABOVE TOP TRACK ATTACHED TO DECK ABOVE WITH STEEL 5TUD KICKERS EXTEND GYP. BOARD 6" ABOVE CEILING TILE I BLDG. 3-5/5" 256 METAL STUDS STANDARD 24" O.G. WITH 5/5" GYPSUM SUSPEND. BOARD EACH 51DE CEILING 5-1/2" SOUND ATTENUATION GATT INSULATION IN WALL BOTTOM I (EXTEND TO 6" ABOVE TRACK CEILING). LAY R-Iq (6") BATTS ATTACHED ON TOP OF ALL CEILING TILE TO TOP OF SLAB 01-01, O�_ TOP OF SLAB (ASSUMED) SECTION - BLDC. 5TANDARD SOUND I N5ULATED PARTITION N.T.S. NOTE: ADA COMPLIANT LAVATORY CLEARANCES SHOWN DASHED. PAPER TOWEL $ SOAP DISPENSER TO BE MOUNTED AT HEIGHT 50 OPERABLE PARTS E55ENTIAL TO BASIC OPERATION ARE WITHIN MAX. REACH SHOWN 56" $ 42" GRAB BARS (1 1/2" DIA) 6 "MAX. 54" S� 12" MIN. MIN. 36" Min. 12" 42" 24" Min. MAX. MIN. v q" Max. TRANSFER SIDE 16" Min. ADA COMPLIANT 15" Max. WATER CLOSET ELEVATION - ADA TOILET N.T.S. LED 5CHEDU WALL 5ASE SCHEDULED WALL BASE TOE CLEARANCE KEYED CONSTRUCTION NOTES:QN NI ALIGN FINISHED FACE OF NEW PARTITIONS. N2 ALIGN FINISHED FACE OF NEW PARTITION WITH FINISHED FACE OF EXISTING PARTITION OR COLUMN. N3 NEW BUILDING STANDARD NON -RATED SOUND INSULATED PARTITION TO 6" ABOVE CEILING SYSTEM, SEE SHEET A.01 FOR WALL LEGEND AND DETAILS. N4 WHEELCHAIR ACCESSIBLE TOILET ROOM; G.G. TO PROVIDE AND INSTALL NEW BUILDING STANDARD ADA COMPLIANT FLOOR MOUNTED WATER CLOSET, LAVATORY, GRAB BARS, MIRROR AND ACCESSORIES AS SHOWN (SEE RESTROOM DETAILS, SECTIONS AND ELEVATIONS AT THIS SHEET AND SEE ENGINEERING R DAWINGR S FOFURTHER DETAILS). N5 PROVIDE AND INSTALL NEW BUILDING STANDARD HI -LOW ADA COMPLIANT DRINKING FOUNTAIN AT TH15 LOCATION, SEE DETAILS AT THIS SHEET AND ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. N6 PROVIDE AND INSTALL NEW BUILDING STANDARD FLOOR MOUNTED MOP SINK WITH NEW INSTANTANEOUS WATER HEATER ABOVE TO SUPPLY HOT WATER TO ALL SINKS. REUSE EXISTING PLUMBING LINES, SEE ENGINEERING DRAWIN65 FOR DETAILS. N7 NEW BUILDING STANDARD MILLWORK. PROVIDE 4 INSTALL 56" OF P.LAM BASE $ UPPER CABINETS AND 36-1/4" SITTING WORK SURFACE WITH GROMMETS. BASE CABINET TO HAVE ONE (4) DRAWER BANK AND NEW BUILDING STANDARD STAINLESS STEEL SINGLE BOWL SINK WITH PADDLE STYLE GOOSENECK FAUCET. PROVIDE HOT WATER FROM JAN CLOSET 121 INSTANTANEOUS WATER HEATER. SEE MILLWORK SHOP DRAWINGS PROVIDED BY SUB -CONTRACTOR AT SHEET A.06. N5 NEW BUILDING STANDARD MILLWORK. PROVIDE 8 INSTALL 36" OF P.LAM BASE 6 UPPER CABINETS AND 32-1/4" SITTING WORK SURFACE WITH GROMMETS. BASE CABINET TO HAVE ONE (4) DRAWER BANK AND NEW BUILDING STANDARD 5TAINLE55 STEEL SINGLE BOWL SINK WITH PADDLE STYLE GOOSENECK FAUCET. PROVIDE HOT WATER FROM JAN CLOSET 121 INSTANTANEOUS WATER HEATER. SEE MILLWORK SHOP DRAWINGS PROVIDED BY SUB -CONTRACTOR AT SHEET A.06. Nq NEW BUILDING STANDARD MILLWORK. PROVIDE 4 INSTALL 66" OF P.LAM BASE 4 UPPER CABINETS. BASE CABINET TO HAVE NEW BUILDING STANDARD 5TAINLE55 STEEL SINGLE BOWL SINK WITH PADDLE STYLE GOOSENECK FAUCET. PROVIDE HOT WATER FROM JAN CLOSET 121 INSTANTANEOUS WATER HEATER. SEE MILLWORK SHOP DRAAIN55 PROVIDED BY 51JB-CONTRACTOR AT SHEET A.06. NIO PROVIDE 4 INSTALL NEW 56" WIDE BUILDING STANDARD P.LAM STORAGE CABINET MILLWORK. SEE MILLWORK SHOP DRAWING-5 BY 5UB-CONTRACTOR AT SHEET A.06. NII NEW BUILDING STANDARD MILLWORK. PROVIDE 8 INSTALL APPROX. 17 L.F. OF P.LAM BASE 4 UPPER CABINETS. BASE CABINET TO HAVE NEW BUILDING STANDARD 5TAINLE55 STEEL SINGLE BOWL SINK WITH PADDLE STYLE GOOSENECK FAUCET. PROVIDE HOT WATER FROM JAN CLOSET 121 INSTANTANEOUS WATER HEATER. SEE MILLWORK SHOP DRAWIN65 PROVIDED BY 5U15-CONTRACTOR AT SHEET A.06. N12 NEW BUILDING STANDARD MILLWORK. PROVIDE 8 INSTALL 142" OF P.LAM SITTING WORK SURFACE WITH (3) BOX/BOX/FILE DRAWER BANKS AND 144" OF NEW P.LAM TRANSACTION TOP. PROVIDE 6ROMMET5 TO ACCESS OUTLETS BELOW COUNTERTOP. SEE MILLWORK SHOP DRAWINGS PROVIDED BY 5UB-CONTRACTOR AT SHEET A.06. N13 NEW BUILDING STANDARD MILLWORK. PROVIDE 4 INSTALL APPROX. 120" OF P.LAM UPPER CABINETS AND STANDING HEIGHT WORK SURFACE WITH ONE (5) DRAWER BANK AND 36" OF SITTING HEIGHT WORK SURFACE WITH GROMMETS FOR OUTLET ACCESS. SEE MILLWORK SHOP DRAWIN65 PROVIDED BY 5U15-CONTRACTOR AT SHEET A.O6. N14 NEW BUILDING STANDARD MILLWORK. PROVIDE 4 INSTALL 55" OF P.LAM BASE 4 UPPER CABINETS. BASE CABINET TO HAVE NEW BUILDING STANDARD 5TAINLE55 STEEL SINGLE BOWL SINK WITH PADDLE STYLE GOOSENECK FAUCET. PROVIDE HOT WATER FROM JAN OL05ET 121 INSTANTANEOUS WATER HEATER. SEE MILLWORK SHOP DRAWINGS PROVIDED BY SUB -CONTRACTOR AT SHEET A.06. N15 NEW BUILDING STANDARD MILLWORK. PROVIDE 4 INSTALL 66" OF P.LAM BASE 4 UPPER CABINETS. BASE CABINET TO HAVE NEW BUILDING STANDARD 5TAINLE55 STEEL SINGLE BOWL SINK WITH PADDLE STYLE GOOSENECK FAUCET. PROVIDE HOT WATER FROM JAN CLOSET 121 INSTANTANEOUS WATER HEATER. SEE MILLWORK SHOP DRAWINGS PROVIDED BY 5UB-CONTRACTOR AT SHEET A.06. NI6 NEW BUILDING STANDARD MILLWORK. PROVIDE 4 INSTALL APPROX. 17 L.F. OF P.LAM BASE 4 UPPER CABINETS. BASE CABINET TO HAVE NEW BUILDING STANDARD 5TAINLE55 STEEL SINGLE BOWL SINK WITH PADDLE STYLE GOOSENECK FAUCET. PROVIDE HOT WATER FROM JAN CLOSET 121 INSTANTANEOUS WATER HEATER. SEE MILLWORK SHOP DRAWINGS PROVIDED BY 5UB-CONTRACTOR AT SHEET A.06. N17 NEW BUILDING STANDARD MILLWORK. PROVIDE 4 INSTALL 106" OF P.LAM BASE $ UPPER CABINETS. SEE MILLWORK SHOP DRAWINGS PROVIDED BY SUB -CONTRACTOR AT SHEET A.06. NI6 NEW BUILDING STANDARD MILLWORK. PROVIDE 4 INSTALL 116-1/5" OF P.LAM SITTING WORK SURFACE WITH (1) BOX/BOX/FILE DRAWER BANK. PROVIDE GROMMETS TO ACCESS OUTLETS BELOW COUNTERTOP. SEE MILLWORK SHOP PRANIN65 PROVIDED BY SUB -CONTRACTOR AT SHEET A.06. NIq NEW BUILDING STANDARD MILLWORK. PROVIDE 8 INSTALL APPROX. 22 L.F. OF P.LAM SITTING WORK SURFACE WITH (4) BOX/BOX/FILE DRAWER BANKS AND APPROX. IcI S L.F. OF GRANITE TRANSACTION TOP. REINSTALL SLIDING WINDOW TRACK AND SLIDING WINDOWS SAVED FROM DEMOLITION PHASE AT RECEPTION/WAITIN6 ROOM OPENING. INSTALL GROMMETS TO ACCESS OUTLETS BELOW COUNTERTOP. SEE MILLWORK SHOP DRAWINGS PROVIDED BY SUB -CONTRACTOR AT SHEET A.06. N20 FIRE EXTIN67UI5HER LOCATION. ALL FIRE EXTINGUISHERS SHALL MEET NFPAIO AND BE RATED AT 2A:IOB:C. VERIFY THAT ANY EXISTING FIRE EXTINOU15HERS ARE RATED AT 2A:IOB:G. N21 CREATE FINISHED DRYWALL OPENING WHERE DOOR FRAME WAS REMOVED. NOTE: SEE COVER SHEET A.OI FOR WALL TYPES, SPECIFICATIONS, DETAILS, SECTIONS, ADDITIONAL CONSTRUCTION NOTES AND DOOR SCHEDULE NOTE: PLANS, WERE DEVELOPED FROM INFORMATION SUPPLIED BY OWNER AND FROM EXISTING CONDITIONS OBSERVED. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND CONDITIONS SHOWN TO BE EXISTING AND SHALL NOTIFY ARCHITECT IN WRITING OF ANY DI5GREPANCIE5 BEFORE SUBMITTAL OF BID AND PROCEEDING WITH THE WORK. COMMENCEMENT OF CONSTRUCTION IMPLIES THAT ALL CONDITIONS, UNLESS PREVIOUSLY DETERMINED AND DOCUMENTED OTHERWISE, ARE IN FACT AS DE50RIBED ON THESE PLANS AND 5PECIFICATION5 AND ACCEPTED AS SUCH BY CONTRACTOR. KNEE CLEARANCE ADA COMPLIANT BATHROOM MIRROR PAPER TOWEL DISPENSER OR AUTOMATIC HAND DRYER SOAP DISPENSER MIN. 2 SECTION - ADA LAVATORY N.T.S. *NOTE: EQUIPMENT PERMITTED HIGHEST I6° IN SHADED AREA. OPERABLE PER "Max.AS 5 WALL TYPE PART OF IS Min. L Y4" x 2" LAG, ACCESSORY BOLTS COVER ADA HI -LOW PLATE PAPER TOWEL 0.... . i DRINKIN6 FOUNTAIN SOLID ESCUTCHEON DISPENSER OR WITH BOTTLE FILLER BLOCKIN6 AUTOMATIC SEE MEP DRAWINGS BETWEEN I )2" DIAMETER HAND DRYER 0 Or 0 FOR SPECIFICATIONS. METAL STUDS 5.5. GRAB BAR AS REQUIRED TRASH m RECEPTACLE DIAM. 6 NOTE: ALL GRAB BARS SHALL BE DESIGNED AND SUPPORTED - z A5 TO WITHSTAND A LOAD OF NOT LESS THAN 200 SCHEDULE m POUN175 APPLIED AT ANY POINT DOWNWARD OR WALL BASE HORIZONTALLY AS REQUIRED BY THE FLORIDA (� 6 ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION MAX. MIN. (PROVIDE SUFFICIENT BLOCKING BEHIND EACH GRAB BAR INSTALLATION). SECTION - ADA HI -LOW 3 DRINKINO FOUNTAIN N.T.S. ELEVATION - TYPICAL GRAB BAR ANCHOR I NO DETAIL ADA MOUNTING HE I OHTS N.T.S. CLG EXAM 114 RM. 5 110 48 GFl _= —j Lu BACK 'I LEAN RM.Wom i R Ill48� R STATION 112 -- N — N jl CORR JAN 121 r CORR OFFICE 120,,,, 1-2 iF PAT E E E E PROCEE Rm. TECH. AREA 119 RECEPTION 102 BUILDING EXTERIOR fNf EXIST VEST. 109 j108 N 7 E 48'GFIO BACK REF_ WORK W. N E49 � E N 7E, N EXAM CLGRM. 4 E@ 04 Io__ I= EXAM RI" I. I I lm3 44�� E �NUU (DE mDE EXIST. WAITING RM. i0i BUILDING EXTERIOR E POWER/COMMUNICATIONS PLAN (t SCALE: I /8"= I'-O" NOR, POKER-00MMUNIGATIONS LEC-oEND b DUPLEX ELECTRICAL RECEPTACLE bGFI DUPLEX ELECTRICAL RECEPTACLE - GROUND FAULT UU44" WJ DUPLEX ELECTRICAL RECEPTACLE, MOUNTED AT A SPECIFIC HEIGHT ABOVE FINISH FLOOR (A.F.F) W DEDICATED DUPLEX ELECTRICAL RECEPTACLE OUADRUPLEX ELECTRICAL RECEPTACLE DEDICATED GUADRUPLEX ELECTRICAL RECEPTACLE VOICE AND/OR DATA OUTLET (SEE NOTE 5 BELOW) 44" VOICE AND/OR DATA OUTLET MOUNTED AT A SPECIFIC HEIGHT ABOVE FINISHED FLOOR (A.F.F.); (SEE NOTE 5 BELOW) BLANK PLATE (] ELECTRICAL JUNCTION BOX (SEE KEYED NOTE a POWER/COMMUNICATIONS PLAN) COAXIAL CABLE OUTLET CLG p [] FLORIDA ACCESSIBILITY CODE -COMPLIANT FIRE ALARM AUDI5LE/5TR05E DEVICE AT CEILING, SEE ELECTRICAL DRAWI1465 FOR EXACT LOCATION 4 DETAILS © ELECTRICAL PANEL BOX "E" - EXISTING OUTLET OR DEVICE TO REMAIN, SEE LEGEND ABOVE FOR SYMBOL DESIGNATION "N" - NEW BUILDING 5TD. OUTLET OR DEVICE, SEE LEGEND ABOVE FOR SYMBOL DESIGNATION "R" - RELOCATED OUTLET OR DEVICE, SEE LEGEND ABOVE FOR SYMBOL DESIGNATION NOTE: ANY OUTLETS NOT SHOWN ON PLAN ARE EXISTING TO REMAIN. MATCH EXISTING OUTLET 4 OUTLET PLATE COVERS REFLECTED GE I L I N6 LEC END 2' x 4' CEILING GRID 0, ACOUSTICAL CEILING TILE BUILDING STANDARD 2' x 4' RECESSED LED LIGHT FIXTURE WITH ACRYLIC LENS BUILDING STANDARD 2' x 2' RECE55ET7 LED FIXTURE W/ACRYLIC LENS OSUSPENDED PROCEDURE LIGHT FIXTURE O BUILDINO STANDARD S" RECESSED LED DOWNLIGHT eDae BUILDING STANDARD CEILING MOUNTED LED EXIT LIGHT WITH BATTERY BACK-UP !jpOR. X BUILDING STANDARD DIRECTIONAL CEILING MOUNTED LED EXIT LIGHT WITH BATTERY BACK-UP ,1► BUILDING STANDARD WALL MOUNTED COMBO EXIT 516N WITH DUAL LAMP EMERGENCY LIGHT FIXTURE WITH BATTERY BACK-UP Amk BUILDING STANDARD CEILING MOUNTED COMBO EXIT S16N WITH DUAL LAMP EMERGENCY LIGHT FIXTURE WITH BATTERY BACK-UP SINGLE POLE SWITCH �3 THREE WAY SWITCH $D DIMMER SWITCH THERMOSTAT EF BUILDING STANDARD EXHAUST FAN, SEE ENGINEERING DRAWINGS FOR DETAILS BUILDING STANDARD MECHANICAL SUPPLY AIR DEVICE, SEE MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND DETAILS BUILDING STANDARD MECHANICAL RETURN AIR DEVICE, SEE MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND DETAILS CLG FLORIDA ACCESSIBILITY CODE -COMPLIANT FIRE ALARM AUDIBLE/STROBE DEVICE AT CEILING, SEE ELECTRICAL DRAWINGS FOR EXACT LOCATION 4 DETAILS a SMOKE DETECTOR "E" - EXISTING TO REMAIN, SEE LEGEND ABOVE FOR SYMBOL DESIGNATION "N" - NEW BUILDING STANDARD, SEE LEGEND ABOVE FOR SYMBOL DE51ONATION "R" - EXISTING RELOCATED, SEE LEGEND ABOVE FOR SYMBOL DESIGNATION MATCH EXI5TINC5 SWITCH 4 SWITCH PLATE COVERS, COLOR AND TYPE REFLECTED GE I L I NC PLAN �5 5(f.-ALE. NORTH lu "` o l� x E Z F O 11IL H z m a H a plu V _Q Lap 0 a 1L p lU w � LU L_ Q Wlu m OL N a SHEET INDEX: PROLNO: 547001 DR./REVIEIVED BY: DATE: REVISION DATES: