Loading...
HomeMy WebLinkAbout38544 5 AveEXISTING SITE AERIAL N.T.S. VERIFY EXISTING PROPANE CAGE PARTIAL SITE PLAN 1" = 10'-0" GENERAL NOTES 1. EXISTING SITE FEATURES SHOWN ON THIS PLAN ARE BASED OFF AERIAL IMAGERY OR BEST AVAILABLE INFORMATION AND SHALL BE VIEWED AS APPROXIMATE. CONTRACTOR SHALL VERIFY MEASUREMENTS IN THE FIELD AND CONTACT DEVELOPMENT SERVICES GROUP (757-908-2372) IF ANY DISCREPANCIES ARE FOUND PRIOR TO START OF CONSTRUCTION. 2, CONTRACTOR SHALL PATCH AND REPAIR EXISTING PAVEMENT AS REQUIRED TO RETURN SURFACE TO EXISTING CONDITION. 3. EXISTING CROSS SLOPES AND EXISTING ACCESSIBILITY COMPLIANCE HAS NOT BEEN VERIFIED AND IS OUTSIDE THE SCOPE OF PROPOSED IMPROVEMENTS. 4. CONTRACTOR SHALL CALL 811 TO REQUEST THAT THE APPROXIMATE LOCATION OF BURIED UTILITIES ARE MARKED PRIOR TO THE START OF CONSTRUCTION. PRIVATE UTILITY LOCATION MAY BE REQUIRED FOR ON -SITE UTILITIES. CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL REGULATIONS REGARDING UNDERGROUND EXCAVATION. 5. BOLLARDS SHALL BE PLACED IN THE PAVEMENT DIRECTLY IN FRONT OF THE BUILDING WHERE A VEHICLE HAS THE POTENTIAL TO PIN PEDESTRIAN AGAINST THE BUILDING. 6. EXISTING WHEEL STOPS CAN BE REMOVED FROM PARKING SPACES WHERE BOLLARDS ARE ADDED. 7. IF THE DEPTH OF THE EXISTING PARKING SPACES NO LONGER MEET THE REQUIREMENTS OF THE LOCAL ORDINANCE, THE CONTRACTOR SHALL RE -STRIPE THE EXISTING PARKING SPACES TO MEET MINIMUM STANDARDS. 8, ALL IMPROVEMENTS SHALL MEET THE CURRENT STATE BUILDING CODE. EXISTING CONCRETE PAVEMENT EXISTING FUEL CANOPY I I 1 L I 1 5TH AVENUE NOTE: ALL PARKING LOT STRIPPING IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED EXISTING DUMPSTER ENCLOSURE -� NEW BOLLARDS, TYPICAL OF 16 LEGEND CONCRETE PAVEMENT ❑ ASPHALT PAVEMENT PROPOSED BOLLARD (TYP OF XX) O EXISTING BOLLARD 1- w Lu ry F— C 0 M cv SECTION A -A N.T.S. 0 g (6") S20 PIPE BOLLARD N.T.S. w a• a 0 CC oa 0 � to ti O O SEE NOTE 10 `tv SEE NOTE 9 - J c3 M 1. MAXIMUM BOLLARD SPACING IS 5'-0" O.C. 2. CONCRETE TO BE 4,000 PSI MIN. UNCONFINED COMPRESSIVE STRENGTH. 3. REINFORCING STEEL CONFORMS TO ASTM A615 GRADE 60. 4. BOLLARD PIPE IS ASTM A53, TYPE E, GRADE B OR A500 GRADE BIC. 5. PROVIDE HIGH DENSITY POLYETHYLENE (HDPE) BOLLARD COVER. COVER TO BE IDEALSHIELD (OR APPROVED EQUAL) 1/8" THICK, BROWN (PQ-440C), 6" PIPE FIT, DOME TOP, 48" TALL. 6. DO NOT FILL BOLLARD PIPE WITH CONCRETE. TEMPORARILY SEAL BOTTOM AS NECESSARY TO PREVENT CONCRETE INTRUSION WHILE POURING. 7. USE SONOTUBE IN SANDY OR OTHER SOILS THAT MIGHT CAVE IN. 8. DIMENSIONS IN PARENTHESIS ARE NOMINAL. 9. COLD JOINT ACCEPTABLE THIS LINE FOR NEW INSTALLATIONS IN MONOLITHIC POUR CONCRETE PAVEMENT. 10. SLOPE TOP OF CONCRETE AWAY FROM BOLLARD 1/4" FROM PIPE TO EDGE OF DRILLED SHAFT OR CAP. 11. INCREASE DEPTH OF CAISSON AND BOLLARD PIPE TO MEET LOCAL JURISDICTION MIN. FROST DEPTH REQUIREMENT. 12. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY NO UTILITY CONFLICTS EXIST WHERE BOLLARDS ARE TO BE INSTALLED, PRIOR TO INSTALLATION. DESIGN SPECIFICATIONS: ASTM F3016-19 CONDITION DESIGNATION S-20 `'-SIDEWALK RAM RAMP '.*SIDEWALK 3 -_PARKING ~ STRIPE N BOLLARD LAYOUT N.T.S. 3 1 /2" 4" 24" 4" CAP REINFORCING DETAIL N.T.S. HDPE BOLLARD COVER 6" SCHEDULE 80 PIPE BOLLARD - DO NOT FILL WITH CONCRETE DRILLED SHAFT CONCRETE FOUNDATION EXISTING CONCRETE CURB AND SIDEWALK MINIMUM 4,000 PSI COMPRESSIVE I I !f STRENGTH WITH FIBER MESH CONCRETE. IlIIN -SITU SOIL all I=I I L I 1 I —I -ro .1 1. - 4 I IIL:�4 4 14" DIAMETER DEEP MOUNT S20 BOLLARD IN CONCRETE PAVING N.T.S. DETAIL A N.T.S. w d o_ 0 00 0 `r m LL O EL Fv M N STOREFRONT BOLLARD DETAILS N.T.S. 3 1 /2" '��_tPROPOSED BOLLARD BOLLARDS LINED UP WITH RAMP LANDING (LANDING WIDTH WILL VARY, MAINTAIN A MINIMUM 4'-5" O.G. SPACING, MAXIMUM 5'-0" SPACING) 001I It I I I I I//// F RA ' No 82120 ' y � � i� O �i � •.�ORIOp•• � Intl Digitally Gary signed by Gary Franks Date: 2024.03. 1 07:14:47 ra., n , -04 00, c 0 a ,U co c� 0 LO v CO o z (050 o T-WO w � D- W Q Z=10 Wes=' W >-'tw _.I .J r W � = O W m m W Lu 2 l O 0 M cv N r N .� Q ASPHALT - Is W o a HDPE BOLLARD COVER o w wvWcn Z�mY W N 0 to U)IhaLL �wZa 6" SCHEDULE 80 PIPE Moo m BOLLARD - DO NOT FILL m a w 6 WITH CONCRETE LOw' C7 T_ CV f— O N DRILLED SHAFT CONCRETE Z co FOUNDATION U) C' �7 Co0 EXISTING CONCRETE CU CURB AND SIDEWALK 0 U) 0 � U m m 8N _E c .p=Np °N2)Zn III a III-11 1 3� 5 co c0 0r�ar� IN -SITU _ "`�❑°'`° G 0-o'? 3 r 1I1=1 ��=�N't3�Q..N 1-1 I 1 ° ' MINIMUM 4,000 PSI COMPRESSIVE STRENGTH WITH FIBER v ! I 1 MESH CONCRETE. fi..—lf Ill=iI II 1 U 18" co DIAMETER REVIEW DATE-` •���..r1.`-� DEEP MOUNT S20 BOLLARD IN CITE' OF 7EI'I•-IYRA ILL ASPHALT PAVING BUILDING 0-!-iCI.AI_ SHEET: N.T.S. CL-1 .0