HomeMy WebLinkAbout38550 Alpha Ave0 • ALL EXTERIOR OUTLETS TO BE WP-GFGI • ALL GARAGE, KITCHEN COUNTER, AND BATHROOM VANITY OUTLETS TO BE GFGI • ALL OUTLETS TO BE ARC -FAULT INTERRUPTER PROTECTED • SMOKE DETECTORS TO BE HARD WIRED IN51DE ALL BEDROOMS AND ONE WITHIN 8' OUT5IDE OF BEDROOMS • SMOKE DETECTOR TO BE AT ALL ENCLOSED STAIRWELLS • ALL BEDROOMS AND DENS TO HAVE STRUCTURED WIRING (GAT-5) FOR GABLE TV, TELEPHONE AND COMPUTER NETWORK TO HUB, OPTIONAL • LIVING ROOM TO BE PRE -WIRED FOR SURROUND SOUND, OPTIONAL • INTERCOM TO FRONT DOOR, ALARM CONTROL, AND DOOR CHIME, OPTIONAL • SERVICE OUTLET TO BE LOCATED WITHIN 10' OF A/C • ALL ELECTRICAL TO BE 12" ABOVE BFE ALL WORK SHALL 0 CODE: YL ; A E_ � ,C. E' NATIONAL EL2CM AND THE CITY OF ORM4ANCES DESIGN CRITERIA: • ALL CONSTRUCTION TO BE IN CONFORMANCE DESIGN AS ENCL05ED w/ FLORIDA BUILDING CODE 2020 7th EDITION, FOR RISK FACTOR II PER SECTION 1609 FLOOD ZONE: X • EXPOSURE "C" LOA05: FLOOR: LL:45 P5F DL:10 PSF • VULT = 150 MPH ROOF: LL: 35 P5 • VA50 = 116 MPH DL: 10 P5F • VULT DESIGN PRE55URE = psf ATTIC: LL: 35 P5F DL: 10 P5F Walls Internal + Internal - Windward 27.2 46.1 DECK: LL: 60 PSF Leeward -32.2 -13.3 DL: 15 P5F Side wall -41.1 -22.1 • DESIGN METHOD: A50 Roof Leeward -41.7 -22.1 LEVEL OF CORROSION RESISTANCE Windward -36.6 -11.1 Parallel -68.5 -49.9 MEDIUM (ALL EXP05ED COMPONENTS REFERENCED STANDARDS MUST BE GALVANIZED MIN.) • 2020 FLORIDA RE51DENTIAL CODE (IF APPLICABLE) • 2020 FLORIDA MECHANICAL CODE • 2020 FLORIDA PLUMBING CODE GG TO SPECIFY FINAL NAVD FLOOR ELEV. • 2020 FLORIDA ENERGY CODE • AGI 315-14 0GG TO PROVIDE SURVEY • ANCl/AWG ND5 - 2015 & SUPPLEMENT AI5C 360-10 0GG TO PROVIDE WINDOW / DOOR NOA's • A5GE/5E17-10 • NFPA70 - 2014 NEC 0IMPACT GLA55 OR 5HUTTER5 NFPA 101 - 2015 (IF APPLICABLE) TO BE USED • ALL ADDITIONAL REFERENCES PER FBG 2020 7TH EDITION, BUILDING GODS CHAPTER 35 13RIAN KONITZER 36550 ALPHA AVE ZEPHERHILL5, FL 33540 I I roi9M'dM-01-1 • CONTRACTOR TO VERIFY ALL DIMENSIONS, SPECIFICATIONS, CONDITIONS & PROPERTY SETBACKS PRIOR TO CONSTRUCTION • ALL CONSTRUCTION SHALL COMPLY WITH ALL LOCAL BUILDING CODES & ORDINANCES AS WELL AS ESTABLISHED BUILDING PRACTICES • ALL RAILINGS TO BE 34"- 55" HIGH (42" @ DECKS) & BALUSTERS SPACED 50 A 4" SPHERE WILL NOT PA55 THROUGH • PLUMBING CONTRACTOR TO VERIFY ALL DIMENSIONS FOR FIXTURES & STUB OUTS ALL MATERIAL BELOW B.F.E. MUST BE WATER RESISTANT, \ P.T. LUMBER & DUROCK DRYWALL, TYP. PER FBG-2020 7TH EDITION 522.1.6. SGOPE OF NORK: FIRE DAMAGE WALL AND TRUSS REPAIR: BUILDING: • REPLACE FIRE DAMAGED TRUSSES • REPLACE WINDOWS/DOORS AS NEEDED • REPLACE ANY DAMAGED PLUMBING AS NEEDED • REPLACE ANY DAMAGED ELECTRICAL AS NEEDED • REPLACE ANY DAMAGED MECHANICAL AS NEEDED • REPLACE HVAC UNIT AND ALL DUCT WORK AND REGISTERS • REPLACE SHEATHING AS NEEDED • REPLACE UNDERLAYMENT AS NEEDED • REPLACE 5HINGLE5 AS NEEDED • REMOVE FIRE DAMAGED INSULATION • INSTALL NEW INSULATION • INSTALL NEW DRYWALL COPYRIGHT ® 202 � Q) O U_ w In Lu t6 i� , U- lCi In Lu O �< �// i� cl7 A L a - N O w w q z 1- wi +_ p d a z es O z> g V O w [�u��auwwza� wzwa����_i size to m � � 7 x ,- N o O 2 O w g d= z E S J 4 1- f.. 7 rt V Q• F ti �tL O r w K 4 F{ < z v w IL z z a z z tr Lu a a w Q O OV v-- R c� w L1 V y 4 �Lu W Lu 6 z CJ I r 4 , zw Z tL /i no U J UA ui !i ! ,any z 4 lu IT >(n J u LL / Lu cL M "M r u.i p ti cOv -T v Y ks) t>! %S) z ts) i ❑❑ SEAL: DATE: MAY 6, 2021 PROJECT STATUS: PRELIMINARY DRAYNN BY: J05EPH G. JOB #: SHEET: 1 of 4 °PLACE (3) YVINDOINS 5.3 P5F •2.7 P5F .'.E A5 NEEDED kCE (1) GARAGE DOOR '5F P5F DAMAGE AREA -46.3 P5F +42.7 P5F DAMAGED AREA FLOOR PLAN 5 6AL 5: 1 /4" = 1 t COPYR16HT 2021 o i N > cn I_- < o Nz � t�K < �. o m a- pp L O W ul = p LLJ T F CI ,t F V3 zKAC=u�?QO � W 4 O F z ti F � a Q� g R Q) O w wow�pi Q 2~ d p N o =wwp��at=ozu�i w F J u. Z F U UA w u w z 7 v z ul ¢ z Q SC < llJ Z r U g d f 0. F O Q L] twit A tU} a ca L Ln ra EQ Q' `n 41 "A ui Q La r V � U_ � *� 400p U tu t J� 4� u; � cr O� `h ❑0 SEAL: i DATE; MAY 6, 2021 PROJECT 5TATU5: PRELIMINARY DR4NN BY: JO5EPH CG. JOB#: 5HEET: 2 of �L60R� ROOF MAIMING REPLACE 2" X 4'' P.T. TOP R-MOYE AND REPLACE V2" PLATE AS NEEDED DRYWALL ON CEILINGAS NEEDED REPLA&iE2"X4"5TUV5 @ ib" O.6.A15 NEEDED REPLACE B0CKfN6 AS NEEDED WE 0, @ 4a" OC, VERT, MAX REPLACE 1/2" DRYY4ALL AS NEFVEv REPLACE 1 r2" DRYWALL. AS NEEDED REPLACE 71 X 4'P.T. BOTTOM FLAr=_ AS NEEDED. ATTACHED wi CASE HARDENED NAILS @ V O.C. NON LQA12[3EAFItj& INIER109 InIALL SE6,T[Obl REMOVE AND REPLACE DAMAGED TRUSSES REMOVE AND REPLACE SHINGLES AS NEEDED REMOVEAND RP_PI_AG'_UNDERLAYMlNTA5N5EVEO REMOVE AND REPLACE SHEATHINC, AS NEEDED REPLACE VZ' DRYWALL. ON CEILINGS r EX15T-'.Nr TO IREM,-,jN REPLACE FIRE DAMAGED TILE, V4000, I CARPET, OR VINYL FLOORING EXISTING FOOTING A TYPICAL (SARA(2E NALL SECTION REMOVE AND REPLACE DAMAGED TRUSSES REMOVE AND REPLACE SHINGLES AS NEEDED REMOVE- AN]) REPLACE UNDERLAYMENT AS N! REMOVE AND REPLACE 5HEATHIN6 REPLACE R-a8 INSULATION AS NEEDED Wl T rwL REPLACE 1/7' VRYYJALL ON LE ICINGS; RF.FLAl_=_ 314" INSULATION BOARD AS NEEDED REPLACE 1/2" PRYVI�'Al L ON HALLS AS N-ErVLD EXJSTIN6TO REP ACE FIRE DAMAlFD TILE, WOOD; CARPET, OR VINYL FLOORIN6 lid !I EXISTING FOOTING A: TYPICAL INTERIQ9 IN8LL 5F.CTIQN G ROOF --FRAMING PLAN 5CALE: 1/4" = 1' / TRUBS DAMAGE AREA COPYRI&HT 2021 JU Lu N > V-- < FL z < U_ < Z Q < Ln LU T LU N 3:LU z C us UA > < tu < � in ,u lu to UT, r­ 7- x cl z z w w 7- X ul Lu < LIA z Q > lij 7- lu LU z Z z < � , ?: Ul Ul IL < lu Z H Lu Q'11 1 En E n (N Ws En W Lk ow z m_ Z W EL tu ia En zuj 4 -t > A U- c) LL UA N lz < ks) z tj) < D F-1 El 5EAL: jai DATE: MAY 6, 2021 PROJECT STATUS: PRELIMINARY DRAWN BY; J05EPH G. JOB #: 5HEFT: U Y - yrfi - � TR 1 GENERAL STRUCTURAL NOTES: CAST IN PLACE CONCRETE FASTENING SCHEDULE THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE CONCRETE MIXES SHALL BE DESIGNED PER ACI 318-14. CONNECTION FASTENER NUMBER OR SPACING DRAWINGS OF ALL OTHER DISCIPLINES AND THE SPECIFICATIONS. THE CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO CONCRETE SHALL CONFORM TO THE FOLLOWING COMPRESSIVE STRENGTH, AND BAND JOIST TO SILL OR TOP PLATE, TOE NAIL 12d 12" O.C. SLEEVES, CHASES, HANGERS, INSERTS; ANCHORS, HOLES, AND OTHER ITEMS TO SLUMP REQUIREMENTS: JOIST TO BAND JOIST, FACE NAIL 16d 3 BE PLACED OR SET IN THE STRUCTURAL WORK. JOIST TO SILL OR GIRDER, TOE NAIL 12d COMMON 3 MEMBER MIN. F'c(28 DAYS) SLUMP NOMINAL MAX BRIDGING TO JOIST, TOE NAIL EACH END 12d COMMON 2 THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY j AGGREGATE LEDGER STRIP 16d COMMON 3 @ EACH JOIST PRECAUTIONS AND OSHA REGULATIONS DURING WORK. THE ENGINEER WILL NOT COLUMN 3000 PSI 4" TO 501 112" SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL 16d COMMON 16" O.C. ADVISE ON NOR ISSUE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS. ; ELEVATED SLABS 3000 PSI 4" TO 5" 3/4" TOP OR SOLE PLATE TO STUD, END NAIL 16d COMMON 2 FOOTING 2500 PSI 5" 3/4" STUD TO SOLE PLATE, TOE NAIL 8d COMMON 4 THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO SLABS ON GRADE 2500 PSI 5" 3/4" DOUBLED STUDS, FACE NAIL 10d COMMON 24" O.C. NOT INDICATE THE METHODS OR MEANS OF CONSTRUCTION. THE CONTRACTOR TIE BEAMS 3000 PSI 5" 1/2"DOUBLED TOP PLATES, FACE NAIL 10d COMMON 16"O.C. SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND! BOND BEAMS 3000 PSI 8" - 11" 1/2" TOP PLATES, LAP & INTERSECTIONS, FACE NAIL ----------- 2-16d OR 3-10d COMMON HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK CONTINUOUS HEADER, TWO PIECES 16d COMMON 16" O.C. ALONG EACH EDGE AND CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN, 3. FOR SALTWATER EXPOSURE USE TYPE III FOR S1 OR TYPE V FOR S2 AND S3 CLG. JOISTS TO PLATE, TOE NAIL 12d COMMON 3 SAFETY, ADEQUACY; AND INSPECTION OF ERECTION BRACING, SHORING, 1 EXEMPTIONS APPLY PER ACI 318-14 TABLE 4.3.7 CONTINUOUS HEADER TO STUD, TOE NAIL 12d COMMON 3 TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CLG. JOISTS, LAPS OVER PARTITIONS, FACE NAIL ------------ 4-1 Od COMMON CONTRACTOR, 4. ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 318-08 CLG. JOISTS TO PARALLEL RAFTERS, FACE NAIL ------------ 3-16d OR 4-10d COMMON & FBC-2014 5TH EDITION BUILDING CODE REQUIREMENTS FOR STRUCTURAL RAFTER TO PLATE, TOE NAIL 12d COMMON 3 THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES CONCRETE. 1" BRACE TO EACH STUD & PLATE, FACE NAIL 8d COMMON 2 AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK. THE SUPERVISION 1 X 8 OR LESS SHTG TO EACH BEARING, FACE NAIL 8d COMMON 2 OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 5, ALL REINFORCED STEEL SHALL CONFORM TO ACI 318-14. OVER 1 X 8 SHTG. TO EACH BEARING, FACE NAIL 8dCOMMON 3 j MIN. REBAR YIELD STRENGTH: Fy = 60.000 PSI BUILT-UP CORNER STUDS 16d COMMON 16" O.C. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION, WHERE BUILT-UP GIRDER & BEAMS, OF THREE MEMBERS 20d COMMON (3) ROWS, 12" O.C. STAGGERED CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OF ; 6. ALL REINFORCING STEEL SHALL BE SET AND TIED IN PLACE PRIOR TO POURING STUDS TO SOLE PLATE, END NAIL 16d COMMON 2 EACH END CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY THE ENGINEER. OF CONCRETE, EXCEPT THAT VERTICAL DOWELS FOR MASONRY WALL TOP PLATE TO TRUSS OR FLOOR JOIST (PERPENDICULAR) 16d COMMON 2 EACH STUD 1 REINFORCING MAY BE "FLOATED" IN PLACE. TOP PLATE TO TRUSS OR FLOOR JOIST (PARALLEL) 16d COMMON 2 EACH STUD LOADING APPLIES TO THE STRUCTURE DURING THE PROCESS OF CONSTRUCTION 2" X 6" SUB FASCIA 10d COMMON (3) PER TRUSS TAIL SHALL NOT EXCEED THE SAFE LOAD- CARRYING CAPACITY OF THE STRUCTURE 7. REINFORCING STEEL, INCLUDING HOOKS AND BENDS, SHALL BE DETAILED IN WOOD STRUCTURAL PANEL SUBFLOORING MEMBERS. THE LIVE LOADING USED IN THE DESIGN OF THIS STRUCTURE ARE ; ACCORDANCE WITH ACI 318-14. ALL REINFORCING STEEL INDICATED AS BEING 15/32", 112", 7/16" 8d COMMON 6" O.C. EDGES & 12" O.C. INTERMEDIATE INDICATED IN THE "DESIGN CRITERIA NOTES". DO NOT APPLY ANY CONSTRUCTION CONTINUOUS (CONT) SHALL BE LAPPED AND BENT PER THE TABLE BELOW. LAP 19/32", 3/4" 8d COMMON 6" O.C. EDGES & 12" O.G. INTERMEDIATE LOADS UNTIL THE STRUCTURAL FRAMING IS PROPERLY CONNECTED TOGETHER CONTINUOUS BOTTOM BARS OVER SUPPORTS, LAP CONTINUOUS TOP BARS AT 1", 1 1/8" 10d COMMON 6" O.C. EDGES & 12" O.C. INTERMEDIATE AND UNTIL ALL TEMPORARY BRACING IS IN PLACE I MID -SPAN UNLESS OTHERWISE NOTED. WOOD STRUCTURAL PANEL ROOF & WALL SHTG. 8d COMMON WALLS 1/2" OR LESS 8d RINSHANK ROOF 4" O.C. EDGES & 6" O.C. INTERMEDIATE G/C. BUILDER TO SUBMIT SHOP DRAWINGS, IN NO CASE SHALL REPRODUCTION 8. UNLESS OTHERWISE NOTED, THE FOLLOWING MINIMUM CONCRETE COVER 19/32" - 3/4" 10d COMMON WALLS OF THE CONTRACT DRAWINGS BE USED AS SHOP DRAWINGS. AS A MINIMUM, SHALL BE PROVIDED FOR REINFORCEMENT: 10d RINSHANK ROOF 4" O.C. EDGES & 6" O.C. INTERMEDIATE SUBMIT THE FOLLOWING FOR REVIEW: HARDBOARD LAP SIDING OVER SHEATHING 8d CORROSION RESISTANT 6" O.C. AT EDGES & 12" Q.C. (a) Concrete cast against and OR PER PRODUCT APPROVALS W/MIN. SHANK DIAMETER OF 0.092" AT INTERMEDIATE A. CONCRETE MIX DESIGNS INCLUDING MASONRY GROUT.i permanently exposed to earth..........................................3" AND MIN. HD. DIAMETER OF 0.225" B. MASONRY CONSTRUCTION MATERIAL CERTIFICATES. (b) Concrete exposed to earth or weather: C. MATERIAL TEST REPORTS FOR MASONRY UNIT STRENGTH fm. No. 6 through No. 18 bars..... ................................ 2" D. REINFORCING STEEL SHOP DRAWINGS. No, 5 bar, W31 or D31 wire, and smaller ..........1-1/2" MASONRY NOTES: E. STRUCTURAL STEEL SHOP DRAWINGS (c) Concrete not exposed to weather or in contact with ground: F. POST -TENSIONED SLAB -ON -GRADE SYSTEM SHOP DRAWINGS. (*} G. PRE -CAST HOLLOW CORE SLABS. (*) Slabs, walls, joists: No. 14 and No. 18 bars MASONRY CONSTRUCTION SHAL CONFORM TO THE REQUIREMENTS OF THE "SPECIFICATION FOR MASONRY STRUCTURES (ACI 530-13)", H. PRE-ENGINEERED WOOD TRUSS SYSTEM. (* SEE NOTES) .......................................2" No. 11 bar and smaller ........................................ 3/4" PUBLISHED BY THE AMERICAN CONCRETE INSTITUTE SEE "TESTING AND INSPECTION NOTES" FOR ADDITIONAL INFORMATION. ITEMS MARKED (*) SHALL HAVE SHOP DRAWINGS AND CALCULATIONS SIGNED AND Beams, columns: Primary reinforcement, ties, stirrups, HOLLOW LOAD -BEARING MASONRY UNITS SHALL CONFORM TO THE ASTM C-90, AND BE MADE WITH NORMAL WEIGHT AGGREGATE. UNIT SEALED BYA FLORIDA REGISTERED ENGINEER. spirals ............... """"""""""""""""""""""""`.....1-1/2 COMPRESSIVE STRENGTH OF 1900 PSI ON NET SECTION TO PROVIDE A MINIMUM NET AREA COMPRESSIVE TR STRENGTH OF MASONRY (fm} OF Shells, folded plate members: 1,500 PSI, AS AS DETERMINED BY THE STRENGTH METHOD OF ACI 530.1 8. CONTRACTOR TO MAKE PROVISIONS OF WINDOW PROTECTION AGAINST FLYING No. 6 bar and larger ............................................ 3/4 DEBRIS. METHOD TO BE APPROVED BY INSPECTOR AT C.O. INSPECTION. No. 5 bar, W31 or D31 wire, and smaller ............ 1/2 FILL ALL BOND BEAMS AND REINFORCED CELLS SOLIDLY WITH GROUT. GROUT SHALL CONFORM TO ASTM C-476 AND SHALL OBTAIN A MIN. 28 DAY COMPRESSIVE STRENGTH OF 2,500 PSI, 8-11" SLUMP, TESTED PER ASTM C-1019 EACH 5,000 S.F. GROUT STOPS ARE TO MESHED OR 9. SIGNED & SEALED FOR STRUCTURAL PORTION OF DRAWING ONLY i9. BAR SUPPORTS AND HOLDING BARS SHALL BE PROVIDED FOR ALL SCREEN TYPE, FELT PAPER IS NOT ALLOWED, 10. PLANS IN ACCORDANCE WITH FBC-2020 7TH EDITION FOR WIND LOADS & REINFORCING STEEL TO INSURE MINIMUM CONCRETE COVER. iBAR SUPPORTS SHALL BE PLASTIC TIPPED OR STAINLESS STEEL. REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ASTM A-615, GRADE 60. SHOP FABRICATE REINFORCING BARS WHICH ARE SHOWN TO PRESSURES AS NOTED IN DESIGN CRITERIA. BE HOOKED OR BENT. DOWELS SHALL HAVE STANDARD 90 DEGREE HOOKS AND LAPPED WITH FIRST LIFT OF REINFORCING. PROVIDE A ------------------ -------------------------------- -- -- - -- ----- - -- 10. ALL EDGES OF PERMANENTLY EXPOSED CONCRETE SURFACES SHALL BE MINIMUM LAP OF 48 WITH A MINIMUM LAP OF 26" FOR #5 REBAR AND GREATER. SITE PREPARATION NOTES: CHAMFERED 3/4" UNLESS OTHERWISE NOTED. MORTAR SHALL CONFORM TO ASTM C-270, TYPE M, S, OR N. ALL MORTAR SHALL MEET THE "PROPORTION SPECIFICATION" OF ASTM C-270 AND THE BUILDING SHALL BE PREPARED AND TESTED IN ACCORDANCE WITH THE 11. FORM -WORK SHALL REMAIN IN PLACE UNTIL CONCRETE HAS OBTAINED AT EVALUATED IN ACCORDANCE WITH ASTM C-780. RECOMMENDATIONS OF THE SOILS ENGINEER. LEAST 90% OF ITS 28 DAY COMPRESSIVE STRENGTH. THE CONTRACTOR SHALL PROVIDE ALL SHORING AND RE -SHORING. UNLESS OTHERWISE INDICATED, ALL WALLS SHALL BE LAID IN RUNNING BOND. BOND CORNERS AND INTERSECTIONS OF ALL LOAD BEARING IF THE SITE PREPARATION REQUIREMENTS ARE NOT SPECIFIED BYA WALLS. INTERSECTING NON -LOAD BEARING WALLS SHALL BE CONNECTED BY PREFABRICATED TEE AND CORNER HORIZONTAL JOINT GEOTECHNICAL REPORT THE FOLLOWING PROCEDURES SHOULD BE USED AS A 12. EPDXY OF REBAR: REINFORCEMENT @ 16" O.C. MINIMUM. SIMPSON SET EPDXY TO BE USED MIN. 4" EMBED OR PER MFGR PROVIDE VERTICAL REINFORCING BARS OF THE GIVEN SIZE AND SPACING AS INDICATED. PROVIDE BARS AT ALL WALL CORNERS, WITHIN AN AREAA MINIMUM OF 5 FEET BEYOND THE BUILDING LIMITS, EXCAVATE A I INTERSECTION AND OPENING EDGES. PROVIDE CLEANOUTS FOR EACH GROUT POUR EXCEEDING 5FT. MINIMUM OF 4" OF EXISTING SOIL. REMOVE ALL ORGANICS, PAVEMENT, ROOTS, i13. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A-185 (FLAT DEBRIS AND OTHERWISE UNSUITABLE MATERIAL. SHEETS ONLY). PROVIDE PRECAST LINTELS ABOVE ALL WALL OPENINGS INCLUDING HVAC DUCTS. SEE DRAWINGS FOR LOCATIONS OF ALL OPENINGS, UNLESS OTHERWISE ON PLAN PROVIDE PRECAST LINTELS BELOW AS A MINIMUM, THE SURFACE OF THE EXPOSED SUBGRADE SHALL BE INSPECTED FOR POCKETS OF SOFT OR UNSUITABLE MATERIAL. EXCAVATE UNSUITABLE SOILAS DIRECTED SLAP ON GRADE NOTES: * OPENINGS LESS THAN 6FT = 8" PRECAST U-LINTEL W/145 & 8" KNOCK -OUT COURSE W/145 BY THE GEOTECHNICAL ENGINEER/TESTING AGENCY. (TYPICAL PERIMETER BOND BEAM 16" TOTAL DEPTH) PROVIDE CONCRETE SLABS OVER R MINIMUM 6 MIL POLYETHYLENE VAPOR * OPENINGS GREATER THAN 6FT. = SEE DRAWINGS FILL ALL EXCAVATED AREAS WITH APPROVED CONTROLLED FILL. PLACE IN 8-INCH BARRIER, PROPERLY LAPPED AND TAPED. PROVIDE ONE REINFORCED CELL EACH SIDE OF OPENING W/ 8" LINTEL BEARING. LIFTS AND COMPACT TO A MINIMUM OF 95% OF THE MAXIMUM DRY DENSITY BASED ON THE MODIFIED PROCTOR TEST. WALKWAYS AND OTHER EXTERIOR SLABS ARE NOT INDICATED ON THE 9. ALL WALLS OVER 8' HIGH MUST BE BRACED PRIOR TO POURING THE BEAMS, STRUCTURAL DRAWINGS. SEE THE SITE PLAN AND ARCHITECTURAL DRAWINGS ALL CONTROLLED FILL MATERIAL SHALL BE A SELECT GRANULAR MATERIAL FREE FOR LOCATIONS, DIMENSIONS, ELEVATIONS, JOINTING DETAILS AND FINISH GENERAL -- NOTES: FROM ALL ORGANICS OR OTHERWISE DELETERIOUS MATERIAL, i DETAILS. PROVIDE 4" WALKS REINFORCED WITH 6X6 - WI AXWI AWWF UNLESS OTHERWISE NOTED. GLAZING TO BE USED AT ALL TUB /SHOWER WINDOWS OR DOORS PROVIDE FIELD DENSITY TESTS FOR EACH 2O00 P.S.F. OF BUILDING AREA FOR EACH LIFT OF CONTROLLED FILL. i ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301, ' "SPECIFICATION ATTIC ACCESS IS REQUIRED ON ALL RESIDENTIAL RESIDENCES. FOR STRUCTURAL CONCRETE BUILDINGS". GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION" ACI 302. HOT WEATHER CONCRETING SHALL BE IN ACCORDANCE W/ACI 306 MIN. ATTIC LIGHT & RECEPTACLE ACCESS SIZE IS 22" X 30" REQUIRED PRE-ENGINEERED TRUSSES NOTES: 1. ROOF WOOD TRUSS SYSTEMS SHALL BE DESIGNED BY THE MANUFACTURER TO STEEL NOTES: CONNECTOR SCHEDULE SUPPORT THE FOLLOWING LOADS: ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE TYPE MODEL# MANUFACTURE UPLIFT CAP. FASTENERS WITH THE "MANUAL OF STEEL CONSTRUCTION" OF THE AISC. A. ROOF TRUSS GRAVITY LOADING CASE A H2.5T SIMPSON 545# 10 - 8d UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE B H5 SIMPSON 455# 8 -8d TOP CHORD LOADING: FOLLOWING ASTM SPECIFICATIONS: C H10S SIMPSON 1010# 16 - 8dX1 1/2" LIVE LOAD: 20 PSF (ON THE HORIZONTAL PROJECTION) D H14 SIMPSON 1350# 12 - 8dX 1 1/2" DEAD LOAD: 25 PSF (ON THE SURFACE AREA) FOR ASPHALT SHINGLES MEMBER ASTM MIN. STRENGTH 13 - 8d 35 PSI (ON SURFACE AREA) FOR CEMENT OR CLAY TILE E LTS SIMPSON 745# 12 - 10d HHS A500 (Grad B) 46 KSI F MTS SIMPSON 1000# 14 - 10d BOTTOM CHORD LOADING: STEEL PIPE A53 (TYPE E, GR B) 35 KSI G SP1 SIMPSON 585# 10 - 10d ATTIC LIVE LOAD: 10 PSF OTHER SHAPES/PLATES A36 36 KSI H SP2 SIMPSON 1065# 12 - 10d ATTIC LIVE LOAD WITH STORAGE: 30 PSF i CONNECTION BOLTS 325(Grad A) 90 KSI I (1)FGTR SIMPSON 5000# 18 SDS 1/4" X 3" DEAD LOAD (FOR 1/2" CD GYPSUM): 5 PSF FOR 1/2" CD GYPSUM I 307(Grad A) 45 KSI 2 1/2" X 5" TITEN TREADED RODS A36 36 KSI J (2)FGTR SIMPSON 9400# 36 SDS 1/4" X 3" B. ROOF TRUSS WIND LOADING CASE 4 1/2" X 5" TITEN 3. ALL CONNECTIONS SHALL BE SHEAR TYPE CONNECTIONS AND DESIGNED BY THE K HETA20 SIMPSON 1810# 9 - 10DX 1 1/2" TRUSSES ARE TO BE DESIGNED FOR WIND LOADING AS SHOWN ON DESIGN j FABRICATOR BASED ON THE AISC MANUAL PART 2 WITH REACTIONS FROM THE "ALLOWABLE ANALYSIS, UPLIFT SHALL DEDUCT 2/3 OF DEAD LOADS. UNIFORM LOAD" TABLES UNLESS REACTIONS ARE SHOWN ON PLAN. SUBMIT SHOP NOTES: DRAWINGS AND CALCULATIONS SIGNED AND SEALED BYA PROFESSIONAL ENGINEER. USP CONNECTORS MAY BE SUBSTITUTED IF THEY MEET OR EXCEED THE UPLIFT VALUES SHOWN. 2. WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE "NDS" 4. ALL WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1 AND AISC 14th EDITION SEC. 8. CONNECTOR SCHEDULE TABLE IS BASED ON LATEST SIMPSON CATALOG, FOR SIP #2 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION ANSI/AF&PAAND USING E70XX ELECTRODES. UNLESS OTHERWISE NOTED, PROVIDE CONT. MIN. SIZED FILLET THE NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS WELDS PER AISC REQUIREMENTS. ALL WELDING SHALL BE DONE BYA CURRENTLY CERTIFIED NOTES: CONSTRUCTION "ANSI/TPI". WELDER IN ACCORDANCE WITH "AWS". STAPLES NOT PERMITTED 3. WOOD MATERIALS SHALL BE SOUTHERN PINE, DOUGLAS FIR OR LARCH AND 15. HOLES IN STEEL FOR OTHER TRADES SHALL BE DRILLED OR PUNCHED AND DETAILED ON DRYWALL NAILS SHALL CONFORM TO ASTM C 514. SHALL BE KILN DRIED AND USED AT 19% MAXIMUM MOISTURE CONTENT. PROVIDE j THE SHOP DRAWINGS. ALL SLOTTED HOLES SHALL BE PROVIDE WITH SMOOTH EDGES. SIDING APPLIED TO 5/8" NET WOOD SHTG, 15/32" WOOD STRUCTURAL PANEL OR 1/2" PARTICLEBOARD SHTG. GRADE NO. 2 OR BETTER REQUIRED TO SATISFY STRESS REQUIREMENTS. BURNING OF HOLES AND TORCH CUTTING AT THE SITE IS NOT PERMITTED. CORROSION RESISTANT NAILS SPACED 6" O.C. AT EDGES & 8" O.C. AT INTERMEDIATE SUPPORTS. NAILS SHALL HAVE A MIN EDGE DISTANCE OF 3/8" 4. CONNECTOR PLATES SHALL BE NOT LESS THAN 0.036 INCHES (20 GAUGE) IN 6. U.O.N. ALL STRUCTURAL STEEL SHALL BE SHOP PAINTED WITH ONE COAT OF TYPE I, RED 5. SIDING APPLIED TO STUDS SPACED 16" O.C. MAX. COATED THICKNESS, SHALL MEET OR EXCEED ASTM A653 GRADE 33 OR HIGHER OXIDE PRIMER PAINT, SEE SPECIFICATIONS. IF APPLICABLE, VERIFY THAT PRIMER COATINGS 6. SIDING APPLIED DIRECTLY TO STUDS SPACE 24" O.C. MAX, AND SHALL BE HOT DIPPED GALVANIZED ACCORDING TO ASTM A-525 (COATING ARE COMPATIBLE WITH SPRAYED ON FIRE PROOFING. 7. USE ANNULAR OR SPIRAL THREAD NAILS FOR COMBINATION SUBFLOOR/UNDERLAYMENT (SINGLE FLOOR) G60). 8. NAIL MUST BE OF SUFFICIENT LENGTH TO ACCOMMODATE THICKNESS OF SIDING AND SHTG. IF USED, 7. COLUMNS, ANCHOR BOLTS BASE PLATES ETC. HAVE BEEN DESIGNED FOR THE FINAL AND ALLOW MIN. STUD PENETRATION OF 1 1/2" 5. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARYAND PERMANENT BRACING COMPLETED CONDITION AND HAVE NOT BEEN INVESTIGATED FOR POTENTIAL LOADING 9. FOR 1" WOOD STRUCTURAL PANELS, 12" O.C. INTERMEDIATE NAILING SHALL BE PERMITTED. AS REQUIRED FOR SAFE ERECTION AND PERFORMANCE OF THE TRUSS. THE ENCOUNTERED DURING STEEL ERECTION AND CONSTRUCTION. ANY INVESTIGATION OF THE SAFE LOAD TABLE FOR CAST -CONCRETE GUIDELINES SET FORTH BY THE TRUSS PLATE INSTITUTION PUBLICATION "HIB-91, COLUMNS, ANCHOR BOLTS, BASE PLATES, ETC, FOR ADEQUACY DURING THE STEEL HIGH -STRENGTH COMMENTARYAND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING ERECTION AND CONSTRUCTION PROCESS IS THE SOLE RESPONSIBILITY OF THE PRECAST &PAE-STRESSED LINTELS METAL PLATE CONNECTED WOOD TRUSSES" SHALL BE A MINIMUM REQUIREMENT. CONTRACTOR. 6. TRUSS MEMBERS AND COMPONENTS SHALL NOT BE CUT, NOTCHED, DRILLED 8. UNLESS OTHERWISE NOTED, ALL STRUCTURAL STEEL PERMANENTLY EXPOSED TO THE LENGTH SAFE LOAD (LB) PER LINEAR FOOT FILLED - 8F16 1T 1 B NOR OTHERWISE ALTERED IN ANY WAY WITHOUT THE WRITTEN APPROVAL OF THE WEATHER, INCLUDING ALL BRICK SHELF ANGLES SHALL BE HOT -DIPPED GALVANIZED IN GRAVITY UPLIFT ACCORDANCE WITH ASTM A153 TRUSS MANUFACTURER S ENGINEER. 4' - 0" 6113 3060 9. PROTECTION COATINGS DAMAGED DURING THE TRANSPORTING, ERECTING AND FIELD 4' - 6" 6113 2707 7. SUBMIT COMPLETE SHOP DRAWING FOR ALL WOOD TRUSSES SHOWING 1 WELDING PROCESSES SHALL BE REPAIRED IN THE FIELD TO MATCH THE SHOP APPLIED 5' - 4" 5365 2276 MEMBER SIZES, SPAN, DIMENSIONS, CHORD PITCH, LOADING AND REACTIONS. COATING. 5' - 10" 4360 2080 SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER AND SHALL BEAR THE 6' - 6" 3480 1868 SEAL OF A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. 10. ALL REINFORCED STEEL SHALL CONFORM TO ACI 318-14. 7' - 6" 2661 1624 MIN. REBAR YIELD STRENGTH: Fy = 60.000 PSI 9' - 4" 2564 1318 8. IF THE NET UPLIFT FORCES SHOWN ON THE FINAL ENGINEERED TRUSS 10'-6" 1533 1180 CALCULATIONS ARE GREATER THAN THE CAPACITY OF THE SPECIFIED 11"-4" 1366 1042 CONNECTORS, THE CONTRACTOR SHALL SUPPLY CONNECTORS TO MEET THOSE WOOD FRAMING NOTES: 12'-0" 1254 940 UPLIFT FORCES AS A MINIMUM, 13'-4" 1075 780 -- ---------------------------------- ------. -- WOOD CONSTRUCTION, CONNECTIONS AND NAILING REQUIREMENTS SHALL CONFORM TO 14'-0" 1002 717 L I THE 2020 FLORIDA BUILDING CODE. REFERENCE FASTENING SCHEDULE TABLE. 14'-8" 1370 663 L L 15'4" 1250 616 (D m ALL WOOD FRAMING MATERIAL SHALL BE SURFACED DRYAND USED AT 19% MAXIMUM 17'-4" 950 506 MOISTURE CONTENT. 1914" 750 429 2114" 598 373 MBAR LAP5PLICE LENGTH OR 60 #3 1 1" 22" ##4 ---""'---- �- #b -- -----21,------------------------------- 331, #7 - - 48" BAR 5TD q00 5TD 1600 HOOK L L m #3 5" " 4 #4 6" 4.5" 511 3R -#5 #b #� -`----a,l --- q„----------- 1 1." ------------- ---' b„ - - -' 7 --------------------- - -- ALL LOAD BEARING WALL FRAMING SHALL BE NO. 2 GRADE SOUTHERN PINE or SPF or P.T. 22'-0" 550 358 24'-0" 450 319 ALL JOIST AND RAFTER FRAMING SHALL BE NO. 2 GRADE, SOUTHERN PINE OR HEM -FIR. NOTES: ALL FRAMING EXPOSED TO THE WEATHER OR IN CONTACT WITH MASONRY OR CONCRETE (FILLED *) ACTING AS A COMPOSITE BEAM TOTAL 16" ONE #5 BAR IN THE LINTEL, ONE #5 BAR IN KNOCK -OUT COURSE. SHALL BE PRESSURE -TREATED IN ACCORDANCE WITH THE AMERICAN WOOD PRESERVERS 5PLICE5 BASED ON 3000 F51 " PER ACI 31 b-OS TABLE 1.2 CONCRETE LAP SPLICE DETAIL STANDARD HOOK DETAILS ASSOCIATION SPECIFICATIONS. ALL P.C. LINTELS & SILLS TO BE CAST-CRETE, SUBSTITUTIONS MAY BE MADE IF THEY i BOLT HEADS SHALL BE CAREFULLY CENTERED AND DRILLED NOT MORE THAN 1/16" LARGER FIRE RESISTANT CONSTRUCTION NOTES: THAN THE BOLT DIAMETER. BOLTED CONNECTIONS SHALL BE SNUGGED TIGHT BUT NOT TO THE EXTENT OF CRUSHING WOOD UNDER WASHERS. GARAGE/ DWELLING PENETRATION PER FBC-R 2020 7TH EDITION (302): MEET OR EXCEED THE ABOVE CAPACITIES, j STUCCO NOTES: 1 STUCCO FINISH PER ASTM 926-C -� PLYWOOD/GYPBOARD SHEATHING NOTES: PREFABRICATED "MICRO -LAM" LUMBER HEADERS AND BEAMS SHALL AS MANUFACTURED MIN, 20 MINUTE RATED SOLID CORE DOOR BETWEEN GARAGE AND RESIDENCE. "TRUSS 7/8" THICK - 3 LAYERS (3/8" SCRATCH COAT, 3/8" ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN BY JOIST MacMILLIAN CORP." BOISE, IDAHO OR APPROVED EQUAL.DO BROWN COAT, 1/$" FINISH COAT) OVER METAL PLYWOOD ASSOCIATION (APA) SPECIFICATIONS. NOT CUT OR NOTCH MICRO -LAM MATERIAL WITHOUT THE MANUFACTURER'S APPROVAL. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING I LATH FASTENED @ 6 O.C. VERT. INTO SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A FRAMING MEMBERS & 2 LAYERS MOISTURE ALL ROOF PANEL SHEATHING SHALL BE 15/32" (1/2" NOM.) EXPOSURE-1 A'PA RATED 18. PREFABRICATED METAL JOIST HANGERS, HURRICANE CLIPS, HOLD-DOWN ANCHORS AND MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MIN. RIGID NONMETALLIC BARRIER. SHEATHING. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY USE OF PANEL OTHER ACCESSORIES SHALL BE AS MANUFACTURED BY "SIMPSON STRONG TIE COMPANY", CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL CLIPS OR BLOCKING BETWEEN FRAMING. SEE NAILING SCHEDULE. NOTE 4" O.C. OR EQUAL. INSTALL ALL ACCESSORIES AS PER THE MANUFACTURES REQUIREMENTS. ALL HAVE NO OPENINGS INTO THE GARAGE PROVIDE WEED SCREED @BOTTOM OF NAILING PATTERN WITHIN 48" OF ALL ROOF EDGES, RIDGES AND HIPS. OVER 1/2" STEEL SHALL HAVE A MINIMUM THICKNESS OF 0.04 INCHES (PER ASTM A446, GRADE A) AND BE GALVANIZED G60). FLANGE SET BELOW TOP OF FOUNDATION AND NOMINAL PLYWOOD, USE 10d NAILS. (COATING DWELLING/GARAGE SEPARATION PER TABLE R302.6. PLATE LINE. t--------'-._... -------------------- --------- - - - - -- INSTALL ALL PLYWOOD SHEATHING WITH THE LONG DIMENSION OF THE PANEL I SEE PLAN SPECIFIC UL LISTING IF NEEDED ACROSS SUPPORTS AND WITH THE PANEL CONTINUOUS OVER TWO OR MORE SPANS. STAGGER PANEL END JOINTS. ALLOW 1/8" SPACING AT PANEL ENDS AND F--- - - - This plan has been designed in general accordance with the latest Florida Building Code for gravity loads and design pressures generated by a wind velocity per the DESIGN CRITERIA. The contractor shall consult these drawings for additional structural notes and specifications and shall confirm EDGES UNLESS OTHERWISE RECOMMENDED BY THE SHEATHING I all field material, conformance and site conditions. Any discrepancies of dimensions, product availability, modifications, or any changes in general MANUFACTURER. I conditions shall be brought to the attention of the engineer immediately, and before proceeding with affected work. The contractor shall provide the ALL NAILING SHALL BE CAREFULLY DRIVEN AND NOT OVERDRIVEN. THE USE OF engineer with truss manufacturers drawings and layout for review and structural interface assessment prior to start with construction. STAPLES ARE PROHIBITED. ASTM & ACI Reports have a copywrite. It will be up to the contractor to obtain these documents. rn A 03 0 m n Jil (P > {f' PR 0 FESS 1 E7 NA L \_ ��`� � o a A"'It,MISTAKES, V� WHILE EVERY ATTEMPT HAS BEEN MADE IN THE PREPARATION OF THESE DRAWINGS TO HYOID AND INCLUDE ALL DETAILS AND PERTINENT INPORMATION.THE DESIGNER CANNOT Proposed Floor Plan For. (1 F Q 1, n % NiIN l \ r fr✓ E L L i../ ' GUARANTEE AGAINST HUMAN ERROR. PRIOR TO THE COMMENCEMENT OF ANY WORK, THE Q �I %� B ! ! IA N KO 1 I TZ E R V I VERIFY ! q20 PALM AVENUE, ELLENTON, FL 34222 PH:�g41-41 i-2034_ . u.E-MAIL: PED@PEI7FL.GOM- I Z � z � G 'u C CONTRACTOR MUST ALL DIMENSIONS, �G DETAILS, .AND INFORMATION PROVIDED IN THESE i DRA,NINGS. CONTRACTOR SHALL CONTACT THE EOR,'N WRITING FORANYOM155[ON5, OR I DISCREPANCIES ON THE DRAWING PRIOR TO THE 35550 ALPHA AVE ! "�✓ ,j' - --�- -�_ -� ❑ LU 15 A. R05ARI O, P.E. FL# 61 u28 ❑ MILAN SLOVAK, P.E. FL# 6162b // 60A #. 2M251 COMMENCEMENT OF ANY WORK. ZEPHERHILL5, FL 33540 -� _.hrl-