HomeMy WebLinkAbout4790 Gall BlvdWARNING
DO NOT EXPOSE CARTONED OR
STACKED PANELS TO MOISTURE
OR HIGH HUMIDITY CONDITIONS
DURING STORAGE. STAINING OR
OXIDIZING OF METAL SKINS MAY
OCCUR.
THIS THERMO-KOOL WALK-IN WILL BE MANUFACTURED
TO UL & NSF REQUIREMENTS. THERMO-KOOL ACCEPTS
NO LIABILITY FOR LOCAL CODE REQUIREMENTS OF
WHICH THERMO-KOOL HAS NOT BEEN MADE AWARE IN
WRITING PRIOR TO FABRICATION.
Thermo-Kool.
WALK-IN PANEL
Thermo-Kool/Mid-South Industries, Inc.
R-14781
��pSSIF��o
C UL US
BUILDING UNITS
1F68
USA
SURFACE BURNING CHARACTERISTICS
MATERIAL DETAILS
FLAME
SMOKE
SPREAD
DEVELOPED
ALUMINUM PANELS PAINTED OR UNPAINTED, 5" OR LESS
15
300-400
GALVANIZED OR STAINLESS STEEL PANELS, PAINTED OR UNPAINTED,
20
450-OVER 500
5 OR LESS
CORE MATERIAL, 9' THICK
1 20
250
CANADA
SURFACE BURNING CHARACTERISTICS / CARACTERISTIQUES
DE
COMBUSTION SUPERFICIELLE IN ACCORDANCE WITH THE
STANDARD / SELON LA NORME
CAN/U LC-S 102
MATERIAL DETAILS / DETAILS DU MATERIAL
FLAME
SMOKE
SPREAD/
DEVELOPED
INDICE DE
INDICE DE
PROPAGATION
DEGAGEMENT
DEL LA
DES FUMEES
FLAMME
ALUMINUM PANELS. PAINTED OR UNPAINTED 127 MM (5 IN.) THICK
10
105
OR LESS, PANNEAUX EN ALUMINIUM, PEINTS OU NON PEINTS 127 MM
(5 PO) D'EPAISSEUR OU MOINS
GALVANIZED OR STAINLESS STEEL PANELS, PAINTED OR UNPAINTED.
127 MM (5 IN) THICK OR LESS, PANNEAUX EN EN ACIER GALVANISE
5
175
OU EN ACIER INOXYDABLE,. PEINTS OU NON (5 PO) D'EPAISSEUR
OU MOiNS
CORE MATERIAL, 150 MM (6 IN.)
MATERIAU DE BASE, 150 MM (6 PO)
295
100
PULL DOWN RATE TO 450 F IS UNRESTRICTED.
AFTER 45 ° F, PULL DOWN RATE SHOULD BE
RESTRICTED TO 100 F PER/ 24 HOUR PERIOD.
NOT APPLICABLE TO BLAST CHILLER CABINETS.
"THERMO-KOOL WALK-IN COOLERS AND FREEZERS
COMPLY WITH 2O18 INTERNATIONAL ENERGY
CONSERVATION CODE (IECC), SECTION C403.10.2"
"MEETS 2018 INTERNATIONAL ENERGY
CONSERVATION CODE STANDARDS".
APPROVED
12u
M
1
INSTALLED
ENCLOSURE -
PANELS
10'-2'
BUILDING CEILING
#8 x 3/4' SHEET METAL SCREWS
12' O.C.
WALK-IN CEILING
1248 SPRING
LOADED HINGE!
WALL
ENCLOSURE PANEL DETAIL
4"-
6'-9' 081.00']
2 -1Q' C34,00']
5'-5' C65.009
2'-10' 034,00']
6'-3' [75,009
TRIM
DIAL THERM
DIAL THERM
TRIM
4„
5
6 917
12
17
20
22
25
27
3
PR
VENT
I
d
8'-2' CL
PR
VENT
—
7'-8' C/L
OOLER
FREEZER
FIAORLESS
FLOORLESS
4
16
31
r
0 0
CLED LIGHT F
XTURE]
CLED
GHT FIXTURE
0 0
ro oN�+
7
10
13
18
23
28
o m
r, i.
FkL0095BSSAMA
/-26
25'-
3
15
�0'60'1M
22•
30
208-230/6010
L - - -
BEL
L_------_J
130BS6EEA
3' DIA, HOLE P
-DRILLED AT
3' 11&
HOLE PRE -DRILLED AT
THERMO-KOOL W
ESC. PLATES
THERMO-KOOL
W/ ESC. PLATES
1
114119
2
8 11
1
21
24
4„
- 11-7' E139.001I 11'-6' 1138.00'1
4„
„4
24'-1' [289.0011
TRIMARK STRATEGIC
ENG, NOTE, REFER TO JOB # 66509 MDLY
NOTE: OVERALL WALK-IN DIMENSI❑NS ARE,
24'-1' x 7'-8' x 9'-6'
NOTE: THERMO-KOOL RECOMMENDS A V MIN. CLEARANCE
BETWEEN WALK-IN & BUILDING WALLS
111111P CLEARANCF:
MINIMUM CLEARANCE REQUIRED FOR
34//X78// D❑❑R IS 48//X87//
CEILING
PANEL
STUCCO ALUMINUM
ESCUTCHEON PLATE
1' THICK LINE KIT INSULATION
l"� #8 x 3/4' SMS
I I C4- PER PLATE)
CEILING
PANEL
• = SILIC❑NE ADHESIVE SEALANT
(BY REFRIGERATI❑N INSTALLER)
POLYURETHANE EXPANDING FOAM (R-4.5 MIN,)
vv (BY REFRIGERATI❑N INSTALLER)
N❑TEI NO LINE KIT INSULATI❑N
THRU PENETRATI❑N, Ei S C 2
ESC1
REFRIG. LINE ESCUTCHEON PLATE DETAIL
5/8'L� / I
NOTE!!!
(REQUIRED CLEARANCE @ DOORS)
INT. SIDE OF DOORI
6' MIN. CLEARANCE REWD ON LATCH
SIDE OF DOOR. SHELVING CAN FLUSH
W/ OPENING ON HINGE SIDE.
EXT. SIDE OF DOOR,
7' MIN, CLEARANCE REWD ON BOTH
SIDES OF DOOR.
AJ
AH AG
AC AB I AA
N❑TEI CUT PLATES IN CENTER OF
C❑LER
DOOR ELEVATI❑N
DOOR SECTI❑N 1,5 AMPS
L THERM
'D PLACARD
HT SWITCH
B-C LATCH
ATE
FREEZER
DOOR ELEVATI❑N
DOOR SECTI❑N 1,5 AMPS
WALK-IN DOO
ADJUSTABLE SWEEP
GASKET
THERM
5/81,
PLACARD
THRESHOLD BACKUPS TO BE
r SWITCH
MOUNTED TO CONCRETE FLOOR
-C LATCH
TE
0
II
VINYL U-CHANNEL SCREED LAYOUT
2" MIN. WOOD
SCREWS (4-REQ'D)
(BY OTHERS)
1/2" DRIVE
ANCHORS (4-REO'D)
12 GA. FLAT
BACKUP
EQU,4L
2„
DOORFRAME
ANCHORMENT
L2 STAIN. STEEL
THRE LD
IN E TH SHOLD BACKUP DESIGNED TO SET ON
TOP ' 2' 10' DOUBLE TREATED WOOD BREAKER
STRIP TO S PORT THRESHOLD r 5/8"
a.
d
LAYERS OF W-MIL
VAPOR BARRIER
(BY G.C.)
a 4 a Q. .
NO THRESHOLD
q ,' "A /8' TILE & GROUT
a' a 4' CONCH
WEARING FLOOR
SECTION THRU
COOLER DOOR
�.
8„ 8-5/8"
WALK-IN DOOR
ADJUSTABLE SWEEP
GASKET
12 GA. STAIN. - STEEL
THRESHOLD
5/8' ANTI SWEAT HEATER
Y: d._' /8' TILE & GROUT
2' X 10' DOUBLE TREATE
WOOD BREAKER STRIP 4' CONE,
° e "
RIPPED DOWN TO FIT WEARING FLOOR �a.. ..
AN 8' RECESS (2) 2' LAYERS OF SLAB
C2) LAYERS ❑ INSULATION, JOINTS
STAGGERED & TAPED
10-MIL VAPOR BARRIER (BY G.0(BY G.C)
G.C.)
SECTION THRU
FREEZER DOOR
COOLER SIDE '
OF PARTITION '
VINYL CREED NEL�I' /
SCREED
CONCRETE
COOLER SIDE I FREEZER SIDE
OF PARTITION OF PARTITION
WALL
SECTION THRU
PARTITION WALL
7'-0' 184.00'1
I
v 3 0
.�+ O J
L
OD_
EU N
Q Q
3/4' C37.75'1
CONDENSING UNIT LAYOUT
HEAVY DUTY STEEL RAISED BASE W/ 1 1/8' LEGS
PREPAINTED G90 GALVANIZED CABINETS, HEAVY DUTY STEEL RAISED BASE WITH 1 1/2' LEGS
UNSCREW WEATHERHOOD AND LIFT OFF PREPAINTED G90 GALVANIZED CABINETS
FOR SERVICE. UNSCREW WEATHERHOOD AND LIFT OFF
24 5/8' FOR SERVICE
2a'I �4v►
FL
PZ�
------- 19 3/4'
BCH0010MCACZ
1, ALL COPPER LINES
2, UNI❑NS AT EVAPORATORS
FOR SERVICE,
3, FREEZER P-TRAP SHALL
BE IN COOLER
4, COOLER DRAIN SHALL BE
PIPED IN DOWN STREAM
❑F FREEZER P-TRAP
BCH0035LCACZ
5, CONDENSATE LINES SHALL
RUN TO BACK WALL, NOT
TO COMMON WALL.
6, SEE INSTALLATI❑N AND START-UP
CHECK LIST FOR DETAILS
7, PR❑VIDE PICTURES OF THE INSTALLATI❑N
ALONG WITH THE CHECK LIST AND INV❑ICE
FOR PAYMENT,
D.KAl1V L11N h UL 1 AIL
FREEZER SIDE
OF PARTITION
NOTEI WALL
RECOMMENDS THAT THE
WALK-IN
WALLL PANEL BE CENTERED OVER
THE 2' X 10' DOUBLE TREATED WOOD BREAKER STRIP,
0
OUTSIDE _
WALL
LOW DENSITY URETHANE'
HIGH DENSITY URETHANE'
U-CHANNEL
SCREED
(2) LAYERS OF
10-MIL VAPOR BARRIER
(BY G.C.)
2' X 10' DOUBLE TREATED
WOOD BREAKER STRIP
RIPPED DOWN TO FIT
AN 8' RECESS
(BY G.C)
SECTION THRU
OUTSIDE FREEZER
WALL
FOR REFERENCE ONLY
PLEASE REFER TO ARCHITECTURAL &STRUCTURAL DRAWINGS FOR SLAB DETAILS
NSF
DATE REV. BY
4-27-2021 CF DRAWN FOR ENGINEERING
NOTICE: This drawing, and all drawings or
specifications submitted by Thermo-Kool,
and reproductions thereof In whole or in
part shall remain the legal property of
Mid -South Industries, Inc., subject to recall
at any time and shall not be used for
installations or production by others except
by our special permission in writing.
Walk-in panels manufactured under
Patent # 5,424,118.
clo C,,A,� hlL/d66831 nnni v
OVERALL DIMENSIONS LENGTH 24'-1" WIDTH
T-$" HEIGHT 9'-6"
FINISH -Exterior
Interior (walls and ceiling)
❑ 26 GA. Stucco Embossed Galv. Steel
❑26 GA. Stucco Embossed Galv. Steel
® .040 Stucco Aluminum
M.040 Stucco ,Aluminum
❑ 20 Ga. Type 304 #3 Finish Stainless Steel
❑ 20 Ga. Type 304 #3 Finish Stainless Steel
❑ White Stucco Aluminum
❑ White Stucco Aluminum
❑ White Smooth Aluminum
❑ White Smooth Aluminum
❑ White Stucco Galv.
❑ White Stucco Galv.
❑ White Smooth Galv.
❑ White Smooth Galv.
❑
❑
FINISH -Interior Floor
® Built-in by others. (Breaker strip must be under all wall panels
including partitions)
p 4" x 2" Vinyl U-Channel Screeds ❑ Wall Anchors
❑ 4 1/4" Foam Screeds ❑2 1/4" Vinyl Screeds
❑14 Ga. Bright Galvanized Steel
❑16 Ga. Stainless Steel SEE DETAIL BELOW
❑Smooth Aluminum
❑Treadbrite Aluminum Foamed -In -Place
❑1/8" Smooth Aluminum Plate Foamed -In -Place
THERMO-KOOL WALK-IN FLOOR PANELS WITH DURA-FLOOR SUPPORT ARE DESIGNED TO WITHSTAND UNIFORMLY DISTRIBUTED
STATIONARY LOADS OF 12,000 LBS. PER SQUARE FOOT. THERMO-KOOL'S WARRANTY DOES NOT COVER DAMAGE DUE TO
PALLET JACKS, MOBILE CARTS, MOBILE SHELVING, FORK LIFTS, OR ANY OTHER FORM OF ROLLING TRAFFIC, A CONCRETE
WEARING FLOOR MUST BE INSTALLED ON TOP OF THE WALK-IN FLOOR PANELS FOR THIS APPLICATION.
::1
SECTION FASTENERS - Thermo-kool cam type Insta-Lok
INSULATION-4" thickness "Foamed -in -place" urethane-DURATHANE CONSTRUCTION CLASS I
❑ OUTDOOR INSTALLATION
❑ Vinyl weather roof W/ Fascia Bar & Cover
❑ Sloped Foam ❑ SQ. FT. OF 4-MIL POLYETHYLENE (FOR BETWEEN SLOPED FOAM & VINYL WEATHERCAP)
❑ Aluminum weather roof by Thermo-Kool (W/ weathercap Trim)
®INDOOR INSTALLATION
ELECTRICAL -All wiring contained within the door sections is 115/60/1 O. Connections to this and all other lights and
refrigeration supplied by others.
ENTRANCE DOOR - Flush infitting type with poly vinyl magnetic gasket and vinyl sweep gasket on bottom edge.
Heater cables are built in around door opening to prevent frost accumulation and sweating. Ext. has a
thermometer, indicating light and toggle switch. Interior has vapor proof light- Hinges are cam action type.
Door finishes will be the same as adjacent panels unless specified otherwise under Door Accessories.
DOOR SIZE & CITY HARDWARE SWING
M (2 ) 34" x 78" ❑1238-C LATCH, (1) 1248-2 HINGE, (1) 1248 SPRING LOADED HINGE, DOOR CLOSER ❑RH
❑ ( ) M1238-C LATCH, (2) 1248 SPRING LOADED HINGES, DOOR CLOSER ®LH
❑( )
®DOOR ACCESSORIES
❑ ( ) 14" x 14" Peep Windows)
❑ ( ) 14" x 24" Peep W ridow(s)
1/8' ALUMINUM TREADPLATE INTERIOR & EXTERIOR KICKPLATES & JAMB GUARDS 36' HIGH
STAINLESS STEEL ON INTERIOR & EXTERIOR OF DOORS &FRAMES
(1) IA PLATE TO READ 'COOLER' (SHIPPED LOOSE)
(1) I D, PLATE TO READ 'FREEZER' (SHIPPED LOOSE)
NO THRESHOLD AT COOLER DOOR
12 Ga, STAINLESS STEEL SPECIAL THRESHOLD AT FREEZER DOOR
BACKUPS IN BOTH DOOR FRAMES FOR CUSTOMER SUPPLIED VINYL STRIP CURTAINS AND VINYL SWING DOORS
NO VP LIGHTS AT DOORS
ALL FIELD SERVICE BOXES AND SWITCHES ON INTERIOR OF WALK-IN TO BE WATER TIGHT
THERMO-KOOL'S SERVICE STICKER WITH THE TOLL FREE NUMBER
TO BE APPLIED NEXT TO SERIAL PLATE ON INTERIOR OF WALK-IN,
®MISCELLANEOUS EQUIPMENT
❑( ) Lights (NOT MOUNTED) 1 AMP EACH
[]interior Floor Ramp
❑Exterior Floor Ramp
2-0# 1830 Heated Pressure Relief Vent(s) - .5 AMPS EACH
❑# 1832-4 Heated Pressure Relief Vent(s) - .5 AMPS EACH
❑# 1825 Heated Pressure Relief Vent(s) - .5 AMPS EACH
®Trim & Enclosures (see detail)
1- 4 FT. L.E.D. COOLER LIGHT FIXTURES) (WITH BULBS) (.4 AMPS)
1- 4 FT. LE,D. FREEZER LIGHT FIXTURES) (WITH BULBS) (4 AMPS)
4' x 2' VINYL U-CHANNEL SCREEDS IN COOLER & FREEZER (PRE-CUT)
ESCUTCHEON PLATES (SEE DETAILS)
3' DIA. HOLE IN CEILING PANELS WITH ESCUTCHEON PLATES (HOLE DRILLED AND ESC. PLATES MOUNTED AT
THERMO-KOOL, SEE PLAN)
ALL FIELD SERVICE BOXES & SWITCHES ON INTERIOR OF WALK-IN TO BE WATER TIGHT
REFRIGERATION - N Aircooled ❑ Watercooled ❑ By Others
1 HP MED TEMP BCH001 OMCACZ-CO635 208-230/60/30 W/ BEL0095BS6AMA 208-230/60/10
CONDENSING UNIT AMPS: MCA 15 MOPD 15 (COMPRESSOR AMPS: 9.5)
COIL AMPS: 1.0
R-448A REFRIGERANT, SCROLL
BTU CAPACITY (ED 35°F ROOM TEMP @ 95°F AMBIENT= 10,050
LIQUID LINE SIZE= 3/8"
SUCTION LINE SIZE = 5/8"
BASE SIZE = 24 5/8" X 28 1/4" X 19 3/4"H
RECEIVER CAPACITY AT 90% FULL: 9 #
CONDENSING UNIT WEIGHT` 179#
HEAT OF REJECTION - 13,065 BTU'S
WITH HAIL GUARD # 59320202
3 1/2 HP LOW TEMP BCH0035LCACZ-X1340 208-230/60130 W/ BEL0130BS6EEA 208-230/60/10
CONDENSING UNIT AMPS:MCA 28.8 MOPD 35 (COMPRESSOR AMPS: 16.3)
COIL FAN AMPS: 1.5
COIL HEATER AMPS: 13.7
R-448A REFRIGERANT, SCROLL
BTU CAPACITY @ -10°F ROOM TEMP @ 90°F AMBIENT = 11,550
LIQUID LINE SIZE = 1/2"
SUCTION LINE SIZE = 7/8"
BASE SIZE = 28 1/4" X 39 1/8" X 19 3/4H
RECEIVER CAPACITY AT 90% FULL: 14#
CONDENSING UNIT WEIGHT: 232#
HEAT OF REJECTION: 17,903
WITH HAIL GUARD # 59301902
BOTH SYSTEMS W/ HEATCRAFT INTELLIGEN CONTROLLER W/ EVAPORATOR CIRCUIT BREAKER
2 FT. ELECTRICAL WIRING HARNESS WILL BE PROVIDED AND PRE -WIRED TO EACH EVAPORATOR BY THERMO-KOOL
BOTH W/ 40 FT PRE -CHARGED LINE KITS
12 FT. DRAIN LINE HEATER FOR THE LOW TEMP. UNIT (115/60/10)
1" THICK LINE KIT INSULATION
COMPLETE COOLER/FREEZER DRAIN LINE KIT TO BE PROVIDED BY THERMO-KOOL
CONTROL KIT - The following controls
indicated with a mark are included.
❑Condensing unit indoor ®Expansion valve
®Condensing unit outdoor ®Dryer
❑ Side Mounted Self Contained ®Sight glass
❑Top Mounted Self Contained ®Temperature control
SQuick Connect ®Remote ❑Top Mounted (Pump down solenoid valve
❑Prewired, Preassembled Remote INTime Clock
®Pressure control
®Suction line vibration eliminator
®Winter control
®Crankcase heater
®Condensing unit cover
WCoil Mounting Kit
NOTES: Aircooled condesing units should be placed in a well ventilated area with a minimum of
1000 CFM's per/H.P.
EVAPORATOR DRAIN CONNECTIONS BY OTHERS
NOTE: THERMO-KOOL recommends V min. clearance between walk-in & building walls. T K N T
REVISION DESCRIPTION
K
Thermo-Kool.
Mld-South Industries, Inc, • P,❑, Box 989
Lo.urel Mlsslsslppl 39441 • Phone 601/649-4600
FAX 601/649-0558
SUBJECT
WALK-IN REFRIGERATION
FOR
CHICK-FIL-A #4040 - ZEPHYRHILLS FSR
ZEPHYRHILLS, FL()A
DR. BY CH. BY DWG: NO-
eF rVA66831
DATE SCALE V SHEET NO.
4-6-2021 3/8"=1'-0" 1 OF 1