HomeMy WebLinkAbout5304 16 StFLOORPLAN SCALE: 1/4" = 1'-0" TOP OF WALL --PRE-CAST LINTEL — 0 0 P.T. WOOD 2x 0 0 —3/16" x 3 1/2" TAPCONS @ 12" O.C. 0 0 FINISHED FLOOR ELEVATION WINDOW BUCK DETAIL @ EXTERIOR WALL n ENGINEER'S NOTES: 1. DESIGN WIND SPEED Vult = 140 MPH 2. BUILDING RISK CATEGORY 2 3. WIND EXPOSURE: $ V(L 4. "2020 FLORIDA BUILDING CODE RESIDENTIAL & BUILDING 7th EDITION" "NFPA 70 & NEC 2017 CODES IN EFFECT' 5. ROOF LIVE LOAD = 20 PSF, DEAD LOAD = 17 PSF 6. ASSUMED SOIL BEARING CAPACITY = 2,000 PSF 7. INTERNAL PRESSURE COEF = +/-0.18 8. CONCRETE COMPRESSION STRENGTH 3000 PSI @ 28 DAYS 1x_ OR 2x_ P.T. W/ TAPCONS @ 12" O.C. MAX DOOR BUCK DETAIL @ EXTERIOR WALL 00 SHINGLE ROOF H2.5 HOLD DOWN STRAPS FL# AL. DRIP EDGE ALUM OR VINYL SOFFIT DBL 2"X 10" PT/YP LUMBER BEAM SIMPSON HD BRACKET# FL# 4X4 PT POST SIMPSON POST BASE # FL# 1/2" X 9" SLEVE ANCHOR 4" NON STRUCTURAL SLAB 2'X2'X2' COL. PAD 3000PS1 CONCRETE W/ 3 #5 REBAR 3" FROM UNDISTURED EARTH & 3 #5 REBAR TURNED 90 DEGREES UNDISTURBED EARTH $ , COLUMN &PAD DETAIL NO SCALE NOTES: 1. 20 GAGE METAL DOOR W/METAL JAMB & DEAD BOLT M.I. WINDDUI SYSTEM VINYL WINDOW FRAME:SCMU BLOCK WALLS GAN BE SUBSTITUDED WITH EQUAL WINDOW SY OTNER MANUFACTURER 26/26 14-3/4" X -12-1/4" 25/25 -14-3/4" X 63" 24/24 -14-3/4" X 50-5/5" 23/23 -14-3/4" X 38-3/8" 22/22 14-3/4" X 26" 36 53-1/8 X 12-1/4 35 53-1/8 X 63 345 53-1/8 X 63 34 53-1/8 X 50-5/8 33 53-1/8 X 35-5/8 32 53-1/8 X 25 26 31-3/4 X 12-1/4 25 31-3/4 X 63 245 31-3/4 X 56-1/4 24 31-3/4 X 50-5/8 23 31-3/4 X 38-5/8 22 31-3/4 X 26 H36 21-1/4 X 12-1/4 H35 21-1/4 X 63 H34 21-1/4 X 50-5/8 H33 21-1/4 X 38-5/8 W33 21-1/4 X 26 I6 IS-1/8 X 12-1/4 15 1S-1/8 X 63 14 1S-1/8 X 50-5/8 13 1S-1/8 X 38-5/8 12 1S-1/8 X 26 ROOF UNDERLAYMENT REQUIREMENTS: Where felt underlayment is used, it must be 30# or equivalent (ASTM D 226 Type II, ASTM D4869 Types III or IV) Undedayment materials required to comply with ASTM D226, D1970, D4869 and D6757 shall bear a label indicating compliance to the standard designation and, if applicable, type classification indicated. Underlayment for roof slopes 2:12 and greater shall be applied and attached in accordance with Section R905.1.1.1, R905.1.1.2 or R905.1.1.3, as applicable. * where self -adhering strips/tapes are applied over roof deck joints, a 30# equivalent underlayment with enhanced fastening is required over the strips/tapes Valleys: Valley linngs shall be installed in accordance with the manufacturer's instructions before applying shingles. Valley linings of the following types shall be permitted: 1. for open valleys (valley lining exposed) lined with metal, The valley lining shall be not less than 16"wide and of any or the corrosion -resistant metals in table R903.2.1 2.For open valleys, valley lining of two piles of mineral -surfaced roll roofing, complying with ASTM D3909, or ASTM D6380 Class M, Shall be Permitted. The bottom layer shall be 18" and the top layer not less than 36" wide. 3. For closed valleys(valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 Class S & not less than 36" wide or valley lining as described in item 1 or 2 shall be permitted. Self -adhering of polymer modified bitumen underlayment complying with ASTM D1970 shall be permitted in lieu of the lining material. PRE-ENGINEERED TRUSSES ON 24" CENTERS W/ HURRICANE STRAPS ON EACH END OF TRUSS SHINGLE ROOF BY CONTRACTOR ON 4869 FELT W/ 1/2" OSB SHEATHING w/ STL PLY CLIPS W/ 8d RING SHANK NAILS @ 6" O.C. EDGE & FIELD HETA16 STRAPS W/ (10) 10d =-1585# MAX (SINGLE -PLY) (2)HETA18 STRAPS=-3170# FL # 11473.3 Ak SEE ELEV. PLAN FOR BRG. HGT� METAL DRIP EAVE 2x6 SUB -FASCIA ALUMINUM: FASCIA EAVE VENT SOFFIT VENTED ALUM. SOFFIT ' NOTE: SOFFITS GREATER THAN 12" SHALL BE PROVIDED w/ INTERMEDIATE NAILING STRIPS (R704) 8" x 8" x 16" CONC. BLOCK SEE ELEVATIONS FOR EXTERIOR FINISH 145 BAR IN FILLED CONC. BLK. CELLS TURN INTO BOND BM. MIN. 12" (SEE FNDTN PL. (PG 3)FOR LOC) VERTICAL STEEL OUT OF SLAB TO HAVE MIN. 25" LAP FINISHED 0'-011 GRADE FIN. FL. 81' 20" STD NO SCALE R-30 INSULATION 1/2" CEILING BOARD OR 5/8" GYP BD 8" CONC. BOND BM. REINF. W/ 145 BAR CONTIN. CONC. FILLED & TURN INTO POURED CELL 25" MIN. 3/4" R-5 INSULATION OR EQUAL 3/4" FURRING @ 16" O.C. 1/2" DRYWALL RECESS AT DOORS AS REQUIRED —BASE MOLDING 4" THICK, 3000 PSI CONCRETE SLAB W/ 6x6 #10-10 WIRE MESH OR FIBERMESH OVER 6 MIL VISQUEEN - TERMITE TREATED 2-#5 REBAR 16" CONT. ,4 TYPICAL WALL SECTION II OPENING SCHEDULE PRODUC CODE SIZE HINGE REVERSED COUNT 36X80 COLONIAL A 1 3'-0" L YES 1 36X80 COLONIAL A 1 3'-0" R NO 1 60X80 PLAIN 2-MODIFIED 4'-0" LR YES 1 48X80 BI FOLD COLONIAL 2 4'-0" LR NO 2 60X80 BIFOLD COLONIAL 2 5'-0" LR NO 3 30X80 COLONIAL A 1 2'-6" L NO 2 30X80 COLONIAL A 1 2'-6" R NO 4 32X80 COLONIAL A 1 2'-8" L NO 1 30X36 SINGLE HUNG 1 2'-611 x T-0" U NA 1 36X60 SINGLE HUNG 1-MODIFIED 3'-0" x 5'-0" U NA 1 36X60 SINGLE HUNG 1 3'-0" x 5'-0" U NA 4 A nit CONSTRUCTION OF FLORIDA, LLC A BETTER CHOICE- DESIGN BUILDER MITCHELL D. VARNEY "DARREL" GENERAL CONTRACTOR ADDRESS: 1115 NW 4TH AVE, OCALA FL. 34475 EMAIL; darrelvamey.abc@gmail.com PHONE: (352) 629-9227 FAX: (352) 629-6429 WEBSiTE: WWW.abcconstructionandremodeling.com Riddle Consulting Engineers, Inc structural civil mechanical Paul D. Riddle, P.E. Senior Engineer COA: 00004759 Paul A. Riddle, Jr. Structural Engineer EMAIL RIDDLEENG a@AOL.COM ADDRESS 1720 SE CTY HWY 484 BELLEVIEW, FL, 34420 PHONE (352) 246-7041 FAX (352) 245-5458 WEBSITE WWW.RIDDLEENGINEERING.COM COPYRIGHT 0 2016 THESE PLANS ARE PROTECTED BY COPYRIGHT LAWS. ANY UNAUTHORIZED USES MAY RESULT IN LEGAL ACTION ENGINEER'S SEAL 011111!//`/ 1\�QPuL D RJ %�� PAUL D. RIDDLE, P.E. P.E. 36989 REVISIONS NOTES PROJECT DATA 1766 � C61 INVESTOR 1000 MODEL �30 i 5304 16TH ST. ZEPHYRHILLS, FL 33542 DRAWING SCHEDULEI Floorplan 1 Elevations 2 Foundation Plan 3 Electrical Plan 4 AREA SCHEDULE NAME AREA Conditioned Area 1026.0 sq ft. DRAWN BY: DARREL VARNEY DATE: 02/16/2021 SCALE: PAGE:1 /4 Floorplan JOB NUMBER TOP OF ROOF 12 5� RIDGE VENT SHINGLE ROOF 12 Top of Plate 5 0 Iry � L1-4- TY 33.7,-36. 33.7,-36.7 + - rF bo T STUCCO FINISH T Top of Subfloor FRONT ELEVATION SCALE: 1/4" = V-0" Top of Plate - Top of Subfloor REAR r'. ,.T... i i SCALE: 1/4" Top of-- Subfloor LEFT ELEVATinN SCALE: 1/4" = V-0" 5 Top of Plate 1 Top of- - -- Subfloor RIGHT ELEVATION SCALE: 1/4" = V-0" 12 �5 8"X 8" CMU COL./W FILLED CELL & (1) #5 REBAR GENERAL VALLEY NOTES: (1) RAFTERS TO BE 2x4 SPACED 24" O.G. UP TO a', USE 2x6 UP TO i2` LENGTH. (2) RAFTER LENGTHS (FROM RIDGE TO CLEAT) OVER 12'-0" TO HAVE (2x4) COLLAR 12 TIE, OR KICKER, AT 1/2 RAFTER SPAN (UP TO 24'-0" MAX RAFTER LENGTH). (3) RIDGE BOARD SHALL BE 2x6 MIN. FOR 2X4 RAFTERS, ! 2X8 MIN. FOR 2X6 RAFTERS. 5 (4) ATTACH RAFTERS 4' OR LONGER TO RIDGE BOARD AND CLEAT USING (i) SIMPSON H2.5 CONNECTOR, NAILED 8-86, ALL OTHERS TOE -NAIL WITH loci. (5) ALL CONVENTIONAL FRAMING LUMBER SHALL BE SPF STUD GRADE OR BETTER. 33.7,-36.7 1 M H2.5 AT END OF w EACH FRAMING MEMBER. (SEE VALLEY NOTE •4 ) 15 COLLAR TIE (AS REQUIRED, SEE GENERAL VALLEY NOTES). �. SIMPSON 1-US26 FASTENED TO PEAK OF PREVIOUS TRUSS. TRUSSES, BELOW (5) IOd GUN NAILS EACH END. ANCHOR TO EACH TRUSS BELOW WITH. (4) IOd NAILS FOR VALLEY RAFTERS UNDER 6' AND LESS. OVER 6' USE SIMF50N H2.5 CLIPS. IF CLEAT IS OVER SHEATHING AND VALLEY RAFTER IS OVER 6', U5E (U 3/8" x 4" LAG SCREW WITH 1" WASHER PER CLEAT, OR CUT SLOT AND BEND FRIGHES RT12112 (OR EQUMETTER) AROUND TRUSS BELOW, SPACED (3) TRUSSES MAXIMUM_ (4) Wd COMMON NAILS • BOTH 9 2x4 BLOCKING e GABLE BRACE - LOCATIONS 2-I0d NAILS EACH TRUSS VALLEY FRAMING DETAIL SCALE: NITS 8d RING -SHANK RAILS 4" O.G. EDGE 4 8" O.G. FIELD USE SIMPSON H4 ON END OF 2X4 FLAT CONT. RUNNER EA LOOKOUT IF DROP GABLE -"r I ACROSS TOP OF BOT CHORD AND BOTTOM OF TOP CHORD 2X4 BLOCKING BETWEEN TRUSSES SECTION A -- --- - GABLE END TRUSS 1/2" SHEATHING FLAT RUNNERgd IN HANK AI R GBNLS . 4" O.G. EDGE < 8" O.G. FIELD w/ 15 LB VAPOR BARRIER (2) LAYERS REQ'D IF DECORATIVE GEMENTITIOUS FINISH t(4) TOT IOd s END OF EACH FLAT 2X4 TOE -NAIL (2) 166 BLOCKING L.4LOCKING70 GABLE END TRUSS LOCKING _ VARIES - MAINTAIN APPROX 45 DEG ANGLE BRACE GABLE END BRACING SCALE: NTS ROOF EDGE STUCCO SPECIFICATIONS PER FBC 4@ - H EDITION R103.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM G 926 and ASTM G 1063 and -the provisions of this code. R-103.6.1 Lath. All lath and lath attachments shall be of corrosion -resistant materials. Expanded metal or woven wire lath shall be attached with 11/2-inch-long (315 mm), 11 gage nails having a 1/16-inch (11.1 mm) head, or -1/8-inchlong (22.2 mm), 16 gage staples, spaced at no more than 6 inches (152 mm), or as otherwise approved. R103.6.2 Plaster. Plastering with Portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be riot less than two coats when applied over masonry, concrete, pressure -preservative treated wood or decay -resistant Wood as Specified in Section R311.1 or gypsum backing. If the plaster surface is completely covered by veneer or other facing material or is completely concealed, plaster application need be only two coats, provided the total thickness Is as set forth in Table R-102.0). On wood -frame construction with an on -grade floor slab system, exterior plaster shall be applied to cover, but not extend below, lath, paper and screed. The proportion of aggregate to cementitious materials shall be as set forth in Table R102.1(3). R103.6.2.1 Weep screed. A minimum 0.019-inch (0.5 mm) (No. 26 galvanlzed sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 31/2 inches (89 mm) shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C S26. The weep screed shall be placed a minimum of 4 inches (102 mm) above the earth or 2 inches (51 mm) above paved areas and shall be of a type that will allow trapped water to gain to the exterior of the building. The weather -resistant barrier shall lap the attachment flange. The exterior lath shall cover and terminate on the attachment flange of the weep screed. R103.6.3 Water-reslative barriers. Water-reststive barriers shall be installed as required to Section R103,2 and, where applied over wood�ased sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and arty flashing (installed in accordance with Section R103.8) intended to drain to the water -resistive barrier Is directed between the layers TOP ELEVATION SCALE: 1/4" = V-0" O ROOF AREA TO BE VENTILATED: 1380 SF (AREAS WITH SOLID CEILING) REQ'D ROOF VENT AREA: 1380 SF/300SF (>1/2 PROVIDED BY RIDGE VENTS)= 4.6 SF ASSUME AT LEAST 50% PROVIDED BY VENTED SOFFIT, 50% PROVIDED BY RIDGE VENTS RIDGE VENT AREA REQ'D = 4.6 SF X 50% = 2.3 SF THEREFORE PROVIDE MINIMUM 2.3 SF OF ROOF VENTILATION BY, OFF RIDGE VENTS, OR STANDARD ROOF VENTS. ASSUME 0.25/ LINEAR FEET OF RIDGE VENT AVAILABLE: 2.34 SF/.025 PER LF = 10 LF OF RIDGE VENT REQ'D. ROOF VENT CALCULATIONS SCALE: 1/4" = V-0" GABLE ROOF (70 < 0-< 450) HIP ROOF (70 450) NOLT609 a = 10% of least horizontal dimension or 0.4 a h, whichever is smaller, but not less than either 4% of least horizontal dimension or 3 It (0.9 m). Exception: For buildings with 0 = 0%%D to 7%%D and a least horizontal dimension greater than 300 It (90 m), dimensi a all be limited to a maximum of 0.8 h h = Mean roof height, in ft (m), except that eave height shall be used for roof angles < 10%%D. 0 = Angle of plane of roof from horizontal, in degrees. MOWS 1. Pressures shown are applied normal to the surface, for Exposure B, at h = 30 ft (9.1 m). Adjust to other conditions using Eq. (30.4-1). 2. Plus and minus signs signify pressures acting toward and away from the surfaces, respectively, 3. For hip roofs with 0 <- 25%%D, Zone 3 shall be treated as Zone 2e and 2r. 4. For effective wind areas between those given, values may be in terpolated; otherwise use the value associated with the lower effective wind area. 5. If overhangs exist, the lesser horizontal dimension of the building shall not include any overhang dimension, but the edge distance, a, shall be measured from the outside edge of the overhang. COMPONENTS AND CLADDING SCALE: 1/4" = V-0" COMPONENTS AND CLADDING BASIC WIND SPEED (MPH) EFFECTIVE 140 150 160 ZONE REA (Fr) 4 10 35.3 -38.2 40.5 -38.2 46.1 -50.0 4 20 33.7 -36.7 38.7 -36.7 44.0 -47.9 4 50 31.6 -34.6 36.2 -34.6 41.2 -45.1 4 100 30.0 -33.0 34.4 -33.0 39.2 -43.1 5 10 35.3 -47.2 40.5 -47.2 46.1 -61.7 5 20 33.7 -44.0 38.7 -44.0 44.0 -57.5 5 50 31.6 -39.8 36.2 -39.8 41.2 -52.0 5 100 30.0 -36.7 34.4 -36.7 39.2 -47.9 ABCCONSTRUCTION 8 OF FLORIDA, LLC A BETTER CHOICE- DESIGN BUILDER MITCHELL D. VARNEY "DARREL" GENERAL CONTRACTOR ADDRESS: 1115 NW 4TH AVE, OCALA FL. 34475 EMAIL; darrelvamey.abc@gmail.com PHONE: (352) 629-9227 FAX: (352) 629-6429 WEBSITE: WWW.abcconstructionandremodeling.com Riddle Consulting Engineers, Inc structural CIVII mechanical Paul D. Riddle, P.E. Senior Engineer COA: 00004759 Paul A. Riddle, Jr. Structural Engineer EMAIL RIDDLEENG@AOL.COM ADDRESS 1720 SE CTY HWY 484 BELLEVIEW, FL, 34420 PHONE (352) 245-7041 FAX (352) 245-5458 WEBSITE WWW.RIDDLEENGINEERING.COM COPYRIGHT (5" 2016 THESE PLANS ARE PROTECTED BY COPYRIGHT LAWS. ANY UNAUTHORIZED USES MAY RESULT IN LEGALACTION ENGINEER'S SEAL D I R/p���// 4P /s 98 . m 8 B ` rATE OF 11- 4.( ® 6�(Aj 1 I \ 0�� � PAUL D. RIDDLE, P.E. P.E. 36989 REVISIONS NOTES PROJECT DATA INVESTOR 1000 MODEL 530416TH ST. ZEPHYRH ILLS, FL 33542 DRAWN BY: DARREL VARNEY DATE: 02/16/2021 SCALE: PAGE:2 /4 Elevations JOB NUMBER 0 N 0 N 3'-4" 6'-8" 31-411 38'-0" 21'-11" 10'-8" 15'-4" 18'-2" 23'-0" 2'-10" 6'-0" 26'-6" 3'-6" 30'-8" 34'-0" 38'-0" 3'-4" ----- -------- -- _----- --- - ---- r-------ram-------- - -------- ---------fit- -- ---L=------_ '- - - - - - - - - - - - - - I I - - - - - - - - -, , - - - - ,-1- - - , m ` - - -` - - - -� - - - - - - - - - - - - - - - - - - - - - - - - - - - ' , - - - - ' - - - - - - - - - -,-,- - - - - - - - - - - - 1 1 21'-3" 11.1 I 1 12'-0%" ' U 1 Li _' I 1 4,,.1 fV 1 yll ' ■ , _o 7'-8%" r ; ~ I 11 1 p; 1 ' 1 I 7'-7Y." WC i + } ASHER r ' 1 's 1 , 1 1 ______ ______-- 1 1 I I DRYER I + 1 r I 1 yr . it ------a ---- - — - --- -------�• a::.r.�� 1- i + , 1 i- '' TUB 5'-2" , 1 ° 9'-1014 1 , LAV. I " 1 , I I I p 1/ I ■' --------------------- ---------------------- -------- - ------------------- ------------. „----- �------- ----'1—iT (T-------------------1�f�liw Iil�f—lt -----------------I�I---- 1i"iT------- 1 T-4" 6'-811 14'-811 18,-0" 19'-2" 34'-0" Foundation Plan SCALE: 1/4" = V-©" TYP MONO FOOTING PVC SLEEVE EXPANDABLE FOAM WASTE PIPE 1.5" MIN 0 STEEL REBAR 3" MIN THICKENED FOOTING TYPICAL CHASE SLEEVE THROUGH INT. OR EXT. MONOLITHIC FOOTINGS SCALE: NTS TYR CHASE SLEVE SCALE: 1/4" = V-0" 38'-0" 23'-6" 24'-2" 30'-811 1#5 REBAR IN FILLED CONC. BLK. CELLS W/3000 PSI CONC. TURNED INTO BOND BM. MIN. 12". SPACED NO MORE THAN 8' O.C. APART, WITH (1) FILLED CELL AT EACH CORNER, AND (1) FILLED CELL ON EA. END OF DOOR AND WINDOW LINTEL 6' OR GREATER.(SEE TYP WALL SECTION FOR DETAILS). SEE FOUNDATION PLAN FOR LOCATIONS PRECAST CONCRETE LINTEL LOAD TABLES FOR MARION MASONRY MATERIALS ALSO DISTRIBUTER OF WEKIWA CONCRETE PRODUCTS, CIVIL & STRUCTURAL ENGINEERING, (SAMUEL GREENBURG P.E. FL REG #34245) MEETS FBC SECTIONS 1901.1.2 & 2103.1. SAFE LOADS VALUES ARE BASED ON LINTELS HAVE A BEARING OF 8" (WITH A MIN ACCEPTABLE BEARING OF 4" PER SECTION 2101.2.1 OF THE FBC). 0 lD O BO r4 N 0 h N MARION MASONRY REINFORCING SCHEDULE AND LOAD CAPACITIES SAFE WORKING LOAD (plf) 8" x 14" RECESS PRECAST LINTELS NO. TOTAL LINTEL LENGTH CLEAR SPAN LINTEL TYPE BOTTOM REINF. GRAVITY SAFE LOAD UPLIFT SAFE LOAD (1)U & (0)L (1)U & (1)L (1)U & (0)L (1)U & (1)L D-1 4'-0" 2'-8" PRECAST (2) #3 9287 10000 8519 10000 D-2 4'-4" T-0" PRECAST (2) #3 7664 8487 7030 9654 D-3 4'-8" 3'-4" PRECAST (2) #3 6430 6526 5897 7280 T-8" 4'-4" PRECAST (2) #4 4217 3918 3752 4176 D 5 6'-8" 5'-4" PRECAST (2) #4 2941 2758 2587 2916 LD-4 D-6 T-8" 6'-4" PRECAST (2) #5 2234 2141 1884 2234 D 7 9'-4" 8'-4" PRECAST (2) #5 1 1513 1455 1116 1513 MARION MASONRY REINFORCING SCHEDULE AND LOAD CAPACITIES SAFE WORKING LOAD (plf) 8/1x16" PRECAST LINTELS NO. TOTAL LINTEL LENGTH CLEAR SPAN LINTEL TYPE BOTTOM REINF. TOP REINF. GRAVITY SAFE LOAD UPLIFT SAFE LOAD (1)U & (0)L (1)U & (1)L (1)U & (0)L (I)U & (1)L L-1 2'-10" 11-61, PRECAST (2) #3 (2) #3 10000 10000 10000 10000 L-2 T-6" 2'-2" PRECAST (2) #3 O #3 10000 10000 10000 10000 L-3 4'-0" 2'-8" PRECAST (2) #3 (2) #3 10000 10000 10000 10000 L-4 4'-6" T-2" PRECAST (2) #3 (2) #3 8221 10000 7549 10000 L-5 4'-8" T-4" PRECAST (2) #3 (2) #3 7544 10000 6927 10000 L-6 5'-4" 4'-0" PRECAST (2) #3 (2) #3 5523 6496 5070 7112 L-7 T-10" 4'-6" PRECAST -#4 (2) #3 5155 5155 4123 5478 L-8 6'-4" '-0. PRECAST 2 #4 2 #3 4210 4210 3415 4449 L-9 6'-6" T-2" PRECAST 2 #4 2 #3 3967 3967 3281 418 L-10 6'-8" T-4" PRECAST (2) #4 (2) #3 3750 3750 3038 3952 L-11 T-6" 6'-2" PRECAST (2) #5 (2) #3 2964 2964 2325 3084 L-12 7-8" 6'-4" PRECAST (2) #5 (2) #3 2840 2840 2213 N53 L-13 8'-0" 6'-8" PRECAST (2) #5 (2) #3 2620 2620 2010 2722 L-14 8'-4" 7-0" PRECAST (2 #5 (2 #3 2431 2431 1832 2524 L-15 9'-4" 8'-01, PR (2) #5 (2) #3 1996 1996 1418 2068 L-16 10'-6" 9'-2" PRECAST 2 #5 2 #3 1647 1647 1085 1704 L-17 IVA" 10'-01, PRECAST (2) #5 (2) #3 1462 1462 911 1512 L-18 1 12'-0" 10'-8" PRECAST (2) #5 (2) #3 1 1341 1341 799 1385 L-19 12'-6" 11'-2" PRECAST (2) #5 (2) #3 1261 1261 727 1303 L-20 13'-4" IZ-011 PRE (2) #5 (2) #3 1147 1147 625 1185 L-21 1`11-01, 12'-8" (2) #5 (2) #3 1069 1069 557 1104 L-22 VV-8" IT-4" PRESTRESSED 2 #5 (2) #3 1299 1299 456 893 L-23 15'-4" 14'-0" PRESTRESSED 2 #5 2 #5 1182 1182 417 820 L-24 17'-4" 16'-0" PRESTRESSED 2 #5 2 #5 910 910 324 639 L-25 19'-4" 18'-0" PRESTRESSED 2 #5 2 #5 719 719 259 511 L-26 20'-0" 18'-8" PRESTRESSED 2 #5 (2) #5 668 668 242 477 L-27 21'-4" 20'-0" PRESTRESSED 2 #5 (2) #5 580 580 212 418 L-28 22'-0" 2V-8" PRESTRESSED 2 #5 2 #5 542 542 199 393 L-29 24'-0" 22'-8" PRESTRESS€D (2 #5 (2) #5 446 446 167 329 GRAVITY SAFE LOAD TABLES - POWER BOX STEEL LINTEL POUNDS PER LINEAR FOOT 8" x 16" WIFILLED (1) #5 MARK LINTEL CLEAR T & B NUMBER SIZE SPAN DETAIL II' P-1 2'-10" P-6" 10831 P-2 T-6" 2'-2" 7463 P-3 4'-0" 2'-8" 6041 P-4 4'-6" Y-2" 5069 P-5 5'.4" 4'-0" 3989 P-6 51-10" 4'-6" 3533 P-7 6'-6" S-2" 3062 P-8 7-6" 6'-2" 2547 P-9 8'-4" T-0" 2230 P-10 9'-4" 8'-0" 1936 P-11 10'-6" 9'-2" 1675 P-12 11'-4" 10'-0" 1526 P-13 12'-6" 11'-2" 1354 P-14 13'-4" 12'-0" 1252 P-15 14'-V' 12'-8" 1180 P-16 14'-8" 13'-4" 1115 P-17 15'-4" 14'-0" 1022 P-18 1T-4" 16'-0" 755 P-19 19'-4" 181-0" 588 P-20 20'-0" 18'-8" 539 P-21 22'-0" 2U-8" 418 P-22 24'-0" 22'-8" 327 P-23 25'-4" 24'-0" 384 P-24 27'-4" 26-0" 309 P-25 29'-4" 28'-0" 251 P-26 31'-4" 30'-0" 203 NOTE: ALL LINTELS GREATER THAN 2Z-8" IN LENGTH WILL REQUIRE (2) #5's BARS TOP OR (2) #5's TOP AND BOTTOM. POWER BOX LINTELS CAN BE PURCHASED FROM G.P. MASONRY OF OCALA 352-873-3500 POWER BOX LINTEL SCALE: 1/4" = 1,'_011 CONCRETE SPECIFICATIONS CONCRETE 1, CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-LATEST, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. 2. CONCRETE SHALL BE NORMAL WEIGHT AND SHALL DEVELOP 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS, UNLESS OTHERWISE NOTED: SPREAD AND CONTINUOUS FOOTINGS 30001=51 WALLS AND GRADE BEAMS 3000P51 SLABS ON GRADE 3000P81 ALL OTHER CONCRETE UNLESS NOTED OTHERWISE 3000PS1 3. ALL CAST IN PLACE CONCRETE TOPPING IS TO BE BONDED TO THE CONCRETE BELOW, 4. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60. 5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM 4185 WITH MINIMUM YIELD STRENGTH OF 65 IGSI 6, PROVIDE FOLLOWING COVER FOR REINFORCING STEEL, UNLESS OTHERWISE NOTED: UNFORMED SURFACES IN CONTACT WITH EARTH 3 IN, UNFORMED SURFACES OVER MOISTURE BARRIERS 2 IN, FORMED SURFACES EXPOSED TO EARTH OR WEATHER OR WATER PROOFING: A. *°6 BARS AND LARGER 211 B, 05 BARS AND SMALLER 1-1/2" FORMED SURFACES NOT EXPOSED TO EARTH OR WEATHER: A. SLABS AND WALLS 3/4" B. COLUMNS 1-1/2" C. BEAMS AND GIRDERS 1-1/2" -1. PROVIDE INTERIOR AND EXTERIOR HORIZONTAL LAPPED CORNER BARS AT ALL CORNERS TO MATCH THE SIZE AND SPACINGS OF THE WALL AND GRADE BEAM REINFORCING, UNLESS NOTED OTHERWISE. 8, LAP SPLICES ID WELDED WIRE FABRIC SHALL BE SUCH THAT THE OVERLAP MEASURED BETWEEN THE OUTERMOST CROSS WIRES OF EACH FABRIC SHEET IS NOT LESS THAN THE CROSS WIRE SPACING PLUS 3 INCHES, 9, REINFORCING BAR DEVELOPMENT LENGTHS Ld: BAR TOP BOTTOM 03 23t1 rill 04 2911 2211 05 3111 2511 'S6 4311 3311 01 6311 4Q" 08 1211 C5�511 10. DEVELOPMENT LENGTH NOTES ARE AS FOLLOWS: A. TOP BARS ARE BARS WITH MORE THAN 12 INCHES OF CONCRETE CAST BELOW. B. HORIZONTAL BARS IN WALL ARE CONSIDERED TOP BARS, C, DEVELOPMENT LENGTHS LISTED ABOVE ARE FOR NORMAL WEIGHT CONCRETE AT 28 DAYS, D. FOR LIGHT WEIGHT AGGREGATE CONCRETE, MULTIPLY ABOVE BY 1.3. 11, PROVIDE DEVELOPMENT LENGTHS PER NOTE 13 UNLESS NOTED OTHERWISE. 12. TENSION LAP SPLICE LENGTH FOR REINFORCING BARS SHALL BE 1.0 Ld FOR CLASS "A" SPLICE AND 13Ld FOR CLASS "B" SPLICE. ALL SPLICES SHALL BE CLASS "B" UNLESS NOTED OTHERWISE. 13.COMPRESSION EMBEDMENT SHALL BE 22 BAR DIAMETERS AND COMPRESSION SPLICE LENGTH 30 BAR DIAMETERS, MINIMUM SPLICE LENGTH TO BE 12 INCHES, 14. USE COMPRESSION EMBEDMENT LENGTHS FOR DOWELS IN THE FOOTINGS AND COMPRESSION SPLICE LENGTH FOR FOOTING DOWELS TO PIER/COLUMN REINFORCING SPLICES, UNLESS OTHERWISE NOTED. 15. WELDED OR MECHANICAL SPLICES CAPABLE OF DEVELOPING 1259a OF BAR YIELD STRENGTH MAY BE USED IN LIEU OF LAP SPLICES. 16, PROVIDE DOWELS TO FOUNDATIONS AT MASONRY WALLS TO MATCH SIZE AND SPACING OF MASONRY WALL REINFORCEMENT, UNLESS NOTED OTHERWISE IN MASONRY WALL DETAILS. 25" LAP LENGTH .o. z Ir a a a a - r a .a f (2) #5 REINF. BARS GRADE 60 OR AS PER PLAN; (SEE TYPICAL WALL SECTION) �o d as CORNER REINFORCEMENT DETAIL Sr -ALE.- NTS CORNER REINFORCEMENT DETAIL SCALE:1/4" = V-011 ABCCONSTRUCTION & REMODEL OF FLORIDA, LLC ABETTER CHOICE- DESIGN BUILDER MITCHELL D. VARNEY "DARREL" GENERALCONTRACTOR ADDRESS: 1115 NW 4TH AVE, OCALA FL. 34475 EMAIL; darrelvarney.abc@gmail.com PHONE: (352) 629-9227 FAX: (352) 629-6429 WEBSITE: WWW.abcconstructionandremodeling.com Riddle Consulting Engineers, Inc structural civil mechanical Paul D. Riddle, P.E. Senior Engineer COA: 00004759 Paul A. Riddle, Jr. Structural Engineer EMAIL RIDDLEENG at?AOL.GOM ADDRESS 1720 SE CTY HWY 4484 BELLEVIEW, FL, 34420 PHONE (352) 245-7041 FAX (352) 245-5458 WEBSITE WWW.RIDDLEENGINEERING.COM COPYRIGHT () 2016 THESE PLANS ARE PROTECTED BY COPYRIGHT LAWS. ANY UNAUTHORIZED USES MAY RESULT IN LEGAL ACTION ENGINEER'S SEAL ,��i�111t6161/ o.3 i39 / ®/ 0 ; �k! ®�✓7j/ Zz- OR- NAL �JPfI I I1�`� PAUL D. RIDDLE, P.E. P.E. 36989 REVISIONS NOTES PROJECT DATA INVESTOR 1000 MODEL 530416TH ST. ZEPHYRHILLS FL 33542 DRAWN BY: DARREL VARNEY DATE: 02/16/2021 SCALE: PAGE: 3 /4 Foundation Plan JOB NUMBER AIR HNDLR DISCONNECT WTR HTR DISCONNECT FLOORPLAN _ ELECTRICAL SCALE: 1/4" = V-0" NOTE AFCI PROTECTION IS REQUIRED ON ALL 125V , 15A & 20A BRANCH CIRCUITS CONDUCTORS (NOT ONLY OUTLETS), IN THE FOLLOWING AREAS: BEDROOMS, REC ROOMS, SUNROOMS, LAUNDRY, DINING, CLOSETS, KITCHENS FAMILY, HALLWAYS, LIVING ROOMS & SIMILAR AREAS. PER CURRENT NFPA 70/NEC 2017 CODES IN EFFECT. ()) 5F-1 yr -.uv .vr rr—r% nr d r r%.. v�.vaiwui i E RISER DETAIL SCALE: 1/4" = V-a" NOTE; P OVODE ARV PROTECTION IN ACCORDANCE WITFI THE NEC - LATEST ELECTRICAL LEGEND ELECTRICAL C _ UNT ceiling fan 3 bladed small 5 can light 6inch 5 0 exterior light 03 2 0 exterior light 03 co detector 2 fan 50 CFM 2 50CC FM outlet 32 outlet gfi 3 smoke detector 3 switch' 14 $ switch 3 Way 1 $3 vanity bar light 02 1 .�. DRAWING SCHEDULE1 ElevationsFloorplan J Foundation Plan 3' Electrical i Plan l ABCOF FLORIDA,'LLC A BETTER CHOICE- DESIGN BUILDER MITCHELL D. VARNEY "DARREL" GENERAL CONTRACTOR ADDRESS: 1115 NW 4TH AVE, OCALA FL. 34475 EMAIL; darrelvamey.abc@gmail,com PHONE: (352) 629-9227 FAX: (352) 629-6429 WEBSITE: WWW.abcoonstructionandremodeling.com Riddle Consulting Engineers, Inc structural civil mechanical Paul D. Riddle, P.E. Senior Engineer COA: 00004759 Paul A. Riddle, Jr. Structural Engineer EMAIL RIDDLEENG@AOL.COM ADDRESS 1720 SE CTY HWY 484 BELLEVIEW, FL. 34420 PHONE (352) 245-7041 FAX (352) 245-5458 WEBSITE WWW.RIDDLEENGINEERING.COM COPYRIGHT C} 2016 THESE PLANS ARE PROTECTED BY COPYRIGHT LAWS. ANY UNAUTHORIZED USES MAY RESULT IN LEGALACTION ENGINEER'S SEAL PAUL D. RIDDLE, P.E. P.E. 36989 REVISIONS NOTES PROJECT DATA INVESTOR 1000 MODEL 530416TH ST ZE'PHYRHILLS, FL 33542 DRAWN BY. DARREL VARNEY DATE: 02/16/2021 SCALE: PAGE: /4 Electrical Plan JOB NUMBER