HomeMy WebLinkAbout6747 North Lake Dr1/2" CDX ROOF SHEATHING NAILED PER ROOF SHEETING DETAIL WITH 8D NAILS, USE STEEL PLYGLIPS , APPROVED UNDERLAYMENT WITH SHINGLES, ENGINEERED ROOF TRUSSES 24" CC. SEE ROOF TRUSS PLAN 1/2" CEILING TYPE 2X4 OR 2X6 WOOD SUB WITH p GYPSUM BOARD ALUMINUM SOFFIT AND FASCIA TRIM SEE LINTEL CHART VINYL FRAME SH WINDOWS MASONRY SILLS 4" CONCRETE SLAB WITH WIRE MESH OR FIBER MESH AND 6 MILL VISQUEEN OVER CLEAN COMPACT TERMITE TREATED SOIL GRADE 411, GROUND WIRE TO 12" "5 VERTICAL RODS FROM FOOTING REBAR FOOTINGS TO BOND BEAM WITH 25" LAP MINIMUM .I Il6" X 12" FOOTINGS WITH If (2) "5 REBAR ON CHAIRS BOTTOM OF FOUNDATION MINIMUM 12" BELOW GRADE BLOCK WALL DETAIL NOT TO SCALE 32' O" ROOF 2X2 WOOD VERTICAL BLOCKING ATTACHED TO FACE OF EACH TRUSS WITH (2) I2D NAILS \ AND EXTENDS DOWN TO SOFFIT LOCATION 4" TO 8" FASCIA INSTALL BEHIND EAVE DRIP SECURE SOFFIT TO -OTT O FFSM A A WIT 24' 4" OGI 7/8" STAPLE. SECURE FASCIA WITH 1 3/4" TRIM NAIL 16" OG INSTALL CONTINUOUS F CHANNEL TO FACE 2X2 CONTINUOUS BATTEN ATTACHED TO OF BLOCK WALL WITH CONTINUOUS IX2 WOOD ' VERTICAL 2X2 BLOCKING WITH I- 12D NAIL BLOCKING WITH 1 5/8" MASONRY FASTENERS 12" OC BLOCK WALL 'EXISTING ALUMINUM SOFFIT PANEL SUNROOM SECURE PANEL TO 2X2 BLOCKING SIMPSON MSHA3.5/11.25" OR EQUAL WITH -1/8" STAPLE OR +8X1" SCREWS HANGER SECURED TO WALL USING 8"OC 5/8"X 6" EXPANSION BOLT AND MAX 24" FILL NAIL HOLES WITH IODXI 1/2 NAILS AT EACH END OF BEAM 45 VERTICAL RODS FROM FOOTINGS 139 MPH WIND SPEED OR LESS DBL 2XI2 •2 PINE BEAM WITH BELOW TOP OF WALL. PLACED AT � ALL CORNERS, EACH SIDE OF ALL - BLOCK WALL SOFFIT DETAIL I/2" PLYWOOD IN CENTER, WRAP OPENINGS AND SPACED MAXIMUM Cx BEAM WITH ALV WIRE LATH AND 4' O' Or -WITH CELLS FILLED SOLID STUr-GO NOT TO SCALE ROOF EDGE 3 20 0 ti% O 1�6 1 O0 O � 2 RIDGE O O 0/0 0 2 0 3 0 00 0 0 ioi ioi 13 GABLE END -O PARTIAL ROOF PLAN ZONE OI 8d RINGS SHANK NAILS AT fc" O-C. AT EDGES Sd RING SHANK NAILS AT fo" O.C. INTERMEDIATE ZONES O 0 Sd RING SHANK NAILS AT 6" O.C., 4" O.G. AT ROOF EDGES, RIDGE LINE, OR GABLE ENDWALL NOTE- END JOINTS FOR SHEATHING SHALL BE STAGGERED AND OCCUR OVER A FRAMING MEMBER. ROOF 5HEATHING NAILING NOT TO SCALE CONTRACTOR TO CONFIRM ROOF PITCH 12 t�6 WALLLEIGI-IT 84" OPTIONAL BRICK DECORATIVE CEI"TENTITIOUS FINISH - - - . _GARACsE FINISH FL0012 -----------------------------_- - -------------•----'---•----'---'----'--- --- O.O.. HATCHED AREAS EXISTING L2 4" PARTIAL FRONT ELEVATION 1 /4" = 11 011 T.B.V. IMMIMMINN--•----- - -- I - - --- - - I I ------ ---- --- ---- --- MAWi wm I—SL ---- ---- 10, -..MKI—rIm. Immomm 'M�—w�� ---- --- --- mmmilmom- ---MMI—ice vno—�—�. ! ■--- ---- ---_�—_i_�_. I ---EN u--ME ---- ---- HATCHED AREAS EXISTING: "2,,. 2' ", OPTIONAL BRICK T.B.V. T.B.V. PARTIAL RIGHT ELEVATION 1/4" = 11 O'1 EXISTING 6'O"X6'8" ' REMOVE EXISTING 25 SH WINDOW AND rCUT AWAY BLOCK DOWN TO SLAB ---------------- , N AND INSTAL NEW EXTERIOR DOOR EXISTING LINTEL TO REMAIN WITH NO m STRUCTURAL CHANGE TO THE OPENING _ NEW u X PORCH m r+ PORCH SLAB 4" BELOW SEE NEW TO EXISTING/HOUSE FINISH FLOOR LOCK WALL DETAIL / / EXISTING MASTER BED NEW NEW REMOVE E)<STING 25 SH WINDOW AND CUT AWAY BLOCK DOWN TO SLAB STORAGE 0 '. � �' GARAGE /AND INSTALL NEW INTERIOR DOOR EXISTNG LINTEL TO REMAIN WITH NO STORAGE SLAB SAME N d F GARAGE SLAB 4" BELOW /STRUCTURAL CHANGE TO THE OPENING LEVEL AS GARAGE HOUSE FINISH FLOOR u IIr/� ' Q I CLOSET SLAB AT SAME • Q J SLOPE GARAGE FLOOR X ELEVATION AS HOUSE i ' Qa FINISH FLOOR I I I I I R-13 INSULATED WALL I N I , I g' 2" I I 23' 10" I /EXISTING I I MASTER BATH L_______ EXISTING 24 SH WITH RADIUS TO 25 SH 8' Sn * 34.50 - 45.92 SEE NEW TO EXISTING BLOCK WALL DETAIL 32' O" FLOOR PLAN 1/4" = 11 O" ALL EXTERIOR WALLS ACT AS SHEAR WALL-0 THESE ADDITION CONSTRUCTION DRAWINGS WERE DESIGNED TO COMPLY WITH ALL OF THE LOADING REQUIREMENTS - SECTION 1103 "STRUCTURAL" OF THE FLORIDA BUILDING CODE 2020 - EXISTING BUILDING -1TH EDITION PRODUCT CATEGORY APPROVED PRODUCT LIST SUB CATEGORY MANUFACTURER STATE FL APPROVV AL STRUCTURAL COMPONET HETA20 SIMPSON FL 11413 STRUCTURAL COMPONET 1`11514A HANGERS SIMPSON FL 13904 STRUCTURAL COMPONET LINTEL HEADER CAST CRETE CORP FL 158.1 ROOFING ASPHALT GAF SINGLES ALL FL 10124.1 ROOFING UNDERLAYMENT GAF FL 10626.1 SINGLE HUNG WINDOWS NON IMPACT PLYGEM 1500 FL 16103.1 SOFFIT E FASCIA TRIM SOFFIT AMERICAN CONSTRUCTION METALS FL 12013.1 EXTERIOR DOORS GARAGE 9'2" TO 16'2" CLOPAY FL 5684.3 25 SH + 34.50 45.92 m N Ln ,V m m 4 z a F-I O r u-LL r �o zLu cntt U r h ~ v 0 In lu Q tu U W z QLL A Qi m 6► 3 2 Q m rr- 1mr- caLu 0 K1 � m�-rau zin x $- =t - so o V �:- Z Z U' Lu Q�La }' U 70 T w \0 0�� O 1 1 tt � • t� i w+w� i � r � HATCHED AREAS EXISTING PARTIAL REAR ELEVATION 1/4" = 11 O" Vj 7 �oAkLw �� Pccw� LIVING CLOSET 105 CD`J C5 I— ORt i 4 41 32X Z3 GARAGE 4 STORAGE 622 ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS TOTAL i68 RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 FIS I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS 1 OF WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 160E OF THE FLORIDA BUILDING CODE 2020 "1 TH EDITION AND ASCE 1-16 FOR 139 MPH WIND ZONE RISK CATEGORY 11 AND THE ENTIRE # 2�212 2020 BUILDING CODE RESIDENTIAL i TH EDITION ARGAY GENERAL NOTES: THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2020 FLORIDA BUILDING GODS SOIL TERMITE TREATMENT: 1 TH EDITION AND THE 2020 FLORIDA BUILDING CODE - RESIDENTIAL -ITH EDITION. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR ARKAY ENGINEERING, INC.: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. ENGINEERING COMPANY: HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE. A "CERTIFICATE OF COMPLIANCE° SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE SHALL STATE FOLLOWING SUPERIMPOSED LOADS: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN FLOOR: TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA LIVE LOAD - 50 P,S,F. DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." DEAD LOAD - ID P.S.F. IF A REGISTERED TERMITICIDE BAIT SYSTEM 15 TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, ROOF: DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE LIVE LOAD (TRUSS TOP CHORD) - 20 P.S.F. OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. 05 P.S,F, WHEN TILE ROOFING IS INSTALLED) BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S,F. MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL, ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P,S,F. WIND: INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, BUILDING IS DESIGNED TO CONFORM TO ASGE 1-16, CHAPTERS 26 THRU 31: PER 2020 FLORIDA BACKFILLING 4 COMPACTION ARE COMPLETE BUILDING CODE, RESIDENTIAL TTH EDITION - SECTION R301,2.1,1. AND 2020 FLORIDA BUILDING ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED CODE 1 TH EDITION SECTION 1605 (INCLUDING ANY BOXED OR FORMED AREAS) - COMPONENT 4 CLADDING WIND LOADS BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE WIND DESIGN ASSUMPTIONS: ALL OTHER WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN BUILDING EXPOSURE - B BUILDING ROOF OVERHANG COMPONENT ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE BUILDING RISK CATEGORY - 11 ZONE LOADS LOADS INITIAL TREATMENT. MEAN ROOF HEIGHT 30' OR LESS HEIGHT 4 EXPOSURE ADJUSTMENT I N/A +32,3/-35.3 A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL COEFFICIENT = LO DILUTION, IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT ENCLOSED BUILDING SHALL BE REQUIRED INTERNAL PRESSURE COEFFICIENT = +/- O.IS 2 65,1 +32,3/-56,2 WIND SPEED SHOWN AT THE BOTTOM RIGHT ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER CORNER OF THIS SHEET 3 -110.6 +32.3/-89.0 MUST ISE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT ALL STRUCTURAL ELEMENTS, EXTERIOR 4 N/A +35,3/-38,2 EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WALLS AND INTERIOR WALLS SHALL BE WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS TYPE V CONSTRUCTION PER FBC 602,5 5 N/A +35,3/-41.2 AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS SOIL BEARING COMPACTION: COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION). ANY SOILS DISTURBED AFTER THE VERTICAL BARRIER 15 APPLIED, SHALL BE RE -TREATED. THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P,5.F, CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE (MINIMUM), THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL BUILDING SIDEWALLS (PER FBC R318), ON THE SITE IS PROPERLY PREPARED 4 COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P,S,F, FOUNDATION LOADING. AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES ARKAY ENGINEERING, INC.: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE NOR PERFORMING ANY SOIL TESTING. THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISBLE FOR THE SITE SOILS ABILITY TO SUPPORT WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION THE BUILDING LOAD5, FOR FUTURE TERMITE INFESTATIONS FOUNDATIONS 4 SLAB -ON -GRADE: TRUSSES: BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA. ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REV15E THE SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS T. L. HANSON 4 ASSOCIATES IS REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY INTENT PRIOR TO COMMENCEMENT OF THE PROJECT, COMPACTED AND TERMITE POISONED SOIL. CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY EXTERIOR WINDOWS 4 DOOR ASSEMBLIES: COMPRESSIVE STRENGTH OF 2,500 P.S.I. ALL EXTERIOR WINDOW 4 GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE 101/152 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY, WITH ASTM A-615, LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" FOR "5 REBAR, 30" FOR *6 REBAR 4 35" FOR *-I REBAR. ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER INSTALL ALL WINDOW 4 DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS FINAL SITE GRADING). THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. ELECTRICAL, PLUMBING 4 MECHANICAL: A FOUNDATION SURVEY SHALL SE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE IN ACCORDANCE WITH CHAPTER 411,003(2)(1) OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL, SITE FOR THE BUILDING INSPEC-ORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO A STRING STRETCHED FROM M—',RKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS, MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, GARAGE AND AT MASONRY WALLS: EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT. CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-SO ALL ELECTRICAL OUTLETS IN HABITABLE SPACES 5F-ALL BE WIRED INTO AN ARC -FAULT INTERRUPTER AND SHALL HAVE A MINIMUM F'M OF 1,500 MORTAR SHALL CONFORM TO ASTM G-210 AND SHALL BE EITHER TYPE M OR S, SAFETY GLAZING: REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE WITH ASTM A-615, LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOU5 LOCATIONS FOR THE PURPOSES OF FOR *5 REBAR, 30" FOR *6 REBAR 4 35" FOR *1 REBAR, GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: (U GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE ASSEMBLIES, OF 3/5", PLAGED AT AN 8 TO 11 INCH SLUMP AND HAVE A MINIMUM 28 DAY GOMPRESSIvE STRENGTH (2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM OF 2,500 P.S,I, (WHEN TESTED PER ASTM C-1019), ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS PROVIDE CLEAN -OUT OPENINGS (12 SQ, IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN THAN 60 INCHES ABOVE THE DRAIN INLET, THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT. HEIGHT, (3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE TIMBER MATERIALS: FINISHED FLOOR OR WALKING SURFACE, ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED (4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS PRIOR TO REQUESTING THE FRAMING INSPECTION, DESCRIBED IN ITEMS (2) AND (3) ABOVE, THAT MEETS ALL OF THE FOLLOWING ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED CONDITIONS: MATERIALS INTERIOR STUD WALLS TO BE OF 2 X 4'"2 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T. A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 60. FT. PINE BOTTOM PLATE AND SINGLE 2 X 4 *2 SPRUCE TOP PLATE WITH STUDS SPACED B) BOTTOM EDGE LE56 THAN 18 INCHES ABOVE THE FLOOR. MAXIMUM 24" OC, WALLS TO HAVE 1/2' GYPSUM BOARD EACH SIDE, WITH WALLS AT C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR, GARAGE TO HAVE MINIMUM R-11 INSULATION D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE PLANE OF THE GLAZING. ATTIC ACCESS: REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R306 FOR ADDITIONAL AREAS THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING. ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SQ, FT. AND HAVING MINIMUM 30 INCHES OF VERTICAL HEIGHT. ROUGH -FRAMED OPENING NOT TO BE LESS THAN 22 X 30 INCHES, WHEN MECHANICAL EQUIPMENT 15 LOCATED IN THE ATTIC, IT SHALL BE INSTALLED IN ACCORDANCE DRAFTSTOPPING: WITH THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION MI305,1.3 IN SINGLE FAMILY DWELLINGS, DRAFTSTOPPING SHALL BE PROVIDED (PARALLEL TO THE MAIN GARAGE. FRAMIMG MEMBERS) IN FLOOR/CEILING ASSEMBLIES SEPARATING USEABLE SPACES. DRAFTSTOPPING SHALL BE CONSTUCTED SUCH THAT THE FLOOR/CEILING ASSEMBLY 15 BROKEN UP INTO TWO OR NO OPENINGS SHALL BE PERMITTED FROM A GARAGE INTO A SLEEPING ROOM_ OTHER OPENINGS MORE APPROXIMATE AREAS WITH NO AREA GREATER THAN 1000 SQ. FT, BETWEEN THE GARAGE AND RESIDENCE SHALL HAVE A DOOR fMIN. 1 3/5" THICK), OF SOLID WOOD, SOLID OR HONEYCOMB CORE STEEL, OR 20-MINUTE FIRE -RATED WITH SELF CLOSING HINGES. WALLS SEPARATING THE GARAGE AND RESIDENCE SHALL HAVE MIN, 1/2" GYPSUM BOARD APPLIED TO THE GARAGE SIDE. THE CEILING SHALL HAVE MIN. 1/2" GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BY ALL HABITABLE ROOMS ABOVE WITH MIN, 5/8" 'TYPE-X' GYPSUM BOARD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R30S PROVIDE PROTECTION FOR ALL APPLIANCES IN GARAGE FROM CAR IMPACT PER FBC SECURING PREHUNG TO BUCK STRIPS PER YOUR MANUFACTURES INSTRUCTIONS TO MEET WIND LOADS AND COMPRESSIONS RATINGS FOR YOUR JOB LOCATION, ALL ATTACH MINIMUM 3/4" P.T. BUCK ANCHOR SCREWS MUST PENETRATE BLOCK GARAGE DOOR TO BE REINFORCED STRIP THAT 15 THE MINIMUM WIDTH WALL A MINIMUM OF 1 1/4" AND THERE SHALL TO MEET WIND LOAD AND COMPRESSION OF DOOR FRAME USING .091XI 3/8" BE A MAXIMUM 1/4" SPACE BETWEEN BUCK RATINGS FOR YOUR JOB LOCATION, T- NAILS MAXIMUM 10" Or-, AND DOOR JAMB CEILING RAFTER CAULK DOOR FRAME MANUFACTURES RECC BLOCK DOOR ATTACHMENT DETAIL NOT TO SCALE ALL TRACK AND HARDWARE SECURED PER MANUFACTURE SPECIFICATIONS TO MEET WIND LOAD AND COMPRESSION RATINGS FOR YOUR JOB LOCATION MINIMUM 2X6 P.T, SIDE PLATE ATTACHED TO BLOCK WALL USING I/2"X5" ANCHOR BOLTS OR 5/8"XY EXPANSION BOLTS 4 EAGH SIDE. ATTACH TOP 2X6 WITH 2 3/8" T NAILS 16" OC GARAGE DOOR ATTACHMENT DETAIL NOT TO SCALE LINTELS ON THIS PROJECT ARE AS SPECIFIED ON THIS CHART UNLESS NOTED ON FLOOR PLAN BY OPENING LINTEL LOAD CHART ( 16" DEEP SECTION ) CLEAR SPAN CONCRETE U LINTEL 2' - 8" 2111 PLF ( UNFILLED ) 3' - 2" 2332 PLF ( UNFILLED ) 4' - O" 1835 PLF ( UNFILLED ) 4' - 6" 1624 PLF ( UNFILLED ) 5' - 2" 213S PLF •• 6' - 2" 2211 PLF •, 1.-0., 1981 PLF =• 8' - 0" 1123 PLF •• 9' - 2" 145S PLF •• 1354 PLF 12-M PLF =• 11, - 2" 1200 PLF •• 12, - O" 1109 PLF u 12' - 8" 1044 PLF •• 13' - 4" 1398 PLF == P 14'-0" 1321PLF uP 1152 PLF •• P IS' -0" 1016 PLF =• P IS' -8 il 911 PLF •• P 20' - 0" 816 PLF == P 22' - 8" 1813 PLF == P •_ - DENOTES *5 REBAR X CONT. PLACED IN EiOTTOM COURSE AND 16" DEEP BEAM POURED SOLID WITH 2500 PSI CONCRETE. •• P - DENOTES PRE STRESSED U LINTEL WITH *5 REBAR X CONT, PLACED IN BOTTOM COURSE 4 16" DEEP BEAM POURED SOLID WITH 2500 PSI CONCRETE 6" X 8" X 16" KNOCK OUT BLOCK TOP COARSE WITH 1 *5 HORIZONTAL 8 , REBAR TIED TO ALL VERTICAL RODS 1� •:- 8" PRECAST LINTEL BLOCK u OVER ALL OPENINGS, I EACH *5 REBAR IN THIS COARSE WHEN SPAN OF LINTEL OVER 5-2" STANDARD PRECAST DETAIL GARAGE FLOOR GALV BRICK WALL TIES AT 12" OC �— VERTICALLY AND SPACED MAXIMUM 6 12" OC HORIZONTALLY WEEP HOLES TYPICAL AT BOTTOM OF BRICK �4" GRADE I 18" OPTIONAL BRICK FOOTING NOT TO SCALE ATTACH MINIMUM 3/4" P.T, BUCK STRIP THAT IS THE MINIMUM WIDTH OF YOUR WINDOW FRAME USING .091 X 1 3/8" T- NAILS MAXIMUM 10" OC CAULKED WINDOW PEP WINDOW MANUFACTURE RECOMMENDATIONS T LOAD AND COMPRES FOR YOUR JOB LOCA 32, O" Tall 24' 4" i i EXISTING SUNROOM *5 VERTICAL RODS FROM FOOTINGS BELOW TO TOP OF WALL. PLACED AT ALL CORNERS, EACH SIDE OF ALL OPENINGS AND 5PACED MAXIMUM 4' 0" Or- WITH SE 1 5 FILLED SOLID 6" EXISTING 6'O"X6'8" REMOVE EXISTING 25 SH WINDOW AND ■ ■ ■ ■ ■ ■ ■ GUT AWAY BLOCK DOWN TO SLAB r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ---------------------------- �r AND INSTALL NEW EXTERIOR DOOR PORCH SLAB 4" BELOW I N EXISTING LINTEL TO REMAIN WITH NO HOUSE FINISH FLOOR STRUCTURAL CHANGE TO THE OPENING X to ■�' '■ i SEE NEW TO EXISTING i BLOCK WALL DETAIL EXISTING ------------------------ MASTER BED STORAGE SLAB SAME AS GARAGE REMOVE EXISTING 25 SH WINDOW AND LEVEL� CUT AWAY BLOCK DOWN TO SLAB AND INSTALL NEW INTERIOR DOOR Q EXISTING LINTEL TO REMAIN WITH NO O STRUCTURAL CHANGE TO THE OPENING Q W 4" NON LOAD BEARING SLOPE GARAGE FLOOR Q 0 STEP IN THE SLAB (LI i Q X GARAGE SLAB 4" BELOW i HOUSE FINISH FLOOR - ' N � o X O i i CLOSET SLAB AT SAME ELEVATION AS HOUSE FINISH FLOOR N / /EXISTING1 r MASTER BATH i EXISTING 24 SH WITH RADIUS TOP SECURING WINDOW TO BUCK STRIPS PER YOUR MANUFACTURES INSTRUCTION TO MEET WIND LOAD AND COMPRESSION RATINGS FOR YOUR JOB LOCATION. ALL ANCHOR SCREWS MUST PENETRATE BLOCK WALL A MINIMUM OF 1 1/4" AND THERE SHALL BE A MAXIMUM 1/4" AND WINDOW FRAME BLOCK WINDOW ATTACHMENT DETAIL NOT TO SCALE 8' 4" 23' 8" i — — — — — — — _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ — — —___ _ _ _ __ — — — _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _________ _ _ _ ________- N 25 SH 25 SH 2' 8" BLOCK WALL DETAIL 32' O" FOUNDATION FLAN 1/411 = 11 0" DRILL 4" HOLE INTO EXISTING BOND BEAM AND EPDXY "B REBAR FROM NEW BCwlr% a = n �.•r INTO EXISTING BOND BEAM. DRILL 4" HOLE INTO EXISTING WALLS 2 AND EPDXY *5 REBAR FROM NEW BL[ INTO EXISTING BLOCK WALL. REBAR Tc LONG WITH 6" INTO EXISTING WALL 6" If BLOCK WALL DRILL 4" HOLE INTO EXISTING FOOTING AND EPDXY "5 REBAR FROM NEW FOO 11 rvc.sa INTO EXISTING FOOTINGS NEW BLOCK WALL TO EXISTING WALL DETAIL NOT TO SCALE m N �n r U m m Q ■z o 0 r U- r z 1 C!) clLL v 1 W z Q O n- m :3 m 4'► 3 di rm W N 0 N i 6 O i } lU W- BRICK LEDGE N m � � N } Q7 N CID O z � O 1— CID Q Q `w T lip '^ V J O QUO ci O � LIVING CLOSET 105 }nORC1-I 41 GARAGE 4 STORAGE 622 g i ARKAY ENGINEERING INC. i STRUCTURAL ENGINEERS TOTAL iro8 ' d $ RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 31296 FG I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS (OFWERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 160E OF THE FLORIDA BUILDING CODE 2020 1 TH EDITION AND ASCE 1-16 FOR 1313 MPH WIND ZONE RISK CATEGORY 11 AND THE ENTIRE # 20212 2020 BUILDING CODE RESIDENTIAL 1 TH EDITION ARKAY % i PLAN �I d USE lU SIMPSON HE-A20 STRAP AT ONE ROOFTRUSS 1 LA ` 1/TI) _ � I O'I WALL. OFILL NAIL HOLES WTHF ALL. ROOF SIODXAT I/2' BLOCK NAILS 2X4 VERTICAL SCAB 9 48" O.G. 2X8 RIDGE BOARD H3 FRAMING (MAX.J CONN, W/ 4-16D NAILS w FSIMFDSCN ANCHOR TYP. 2X8 RIDGE BOARD TOP 4 SIMPSON "H3" ROOF SHEATHING HURRICANE CLIP AT BOTTOM. CONT, 2X4 2" X 6" (•2 YELLOW PINE) VERT, SCAB RAFTERS a 24" O.G. BEVEL CUT SIMPSON "H3" TYP. 4-16D TOE NAILS 'w HURR. STRAP m CONT. 2X4 RIDGE BOARD END EACH END NAILER TYP. (2-1hD NAILS PER TRUSS) SIMPSON "H3" HURR. STRAP lo SIMPSON "H3" 48" O.G. TYP, SECTION "A"-"AllHURR. STRAP g 40" O.G. TYP. 2X4 NAILERS (TYP.) END NOT EXPOSED TO WIND ROOF VALLE*r DETAIL NOT-TO-SGALE BUSSES BELOW SHEATHED RIOR TO VALLEY FRAMING 45TALLATI ON. 6 (*2 YELLOW PINE) VALLEY FRAMING (TYP.) COMMON TRUSS IL WOOD FRAME 4R 'AIII OL "FA- nc - - _ ECCti'.r, ENDOL CNS CMU WALL ^KC hr-_ YVEKBUILDI.NG --�� WINDOW FLANGE - --- WRAP AT WOOD FRAME LOCATIONS SrURED TO WOOD BUCK AS PERWINDOW MANUFACTURES RECOMMENDATIONS WINDOW FLANGE SECURE TOINOOD BUCK AS PER j� WINDOW MANUFACTURES \ RECOMMENDATIONS ' �\ WOOD FRAME - OR CMU WALL APPLY SILL PEEL & STI-'K FLASHING OVER FLANGE VERIF INSTALLATION W/ SEECTED MANUFACT. APPLY VERTICAL PEEL WINDOW FLANGE SECURED TO RECOMMENDATION: amFLANGE & STICK FLASHING OVER VERIFY INSTALL, W/ SELECTED MANUFACT. I , RECOMMENDATIONS WOOD BUCK AS PER WINDOW MANUFACTURES RECOMMENDATIONS NOTE: STEP #1 STEP #2 CONTRACTOR TO FLAIH AND SEAL ALL WINDOW AND DOOR OPENINGS PER THE MANUFACTURER'S RECOMMENDATION AND SHALL PROVIDE A COMPLETE WATER TIGHT SEAL. FLASHING DOTES: PROVIDE CORROSIOI,RESIST VE FLASHING IN THE EXTERIOR WALL ENVELOPE TO PREVENT ENTRY OF WATER INTO THE WALL CAVTFY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAWNG COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH AND SHALL BE INSTALLED TO PREVENT WATER FROM REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT THE FOLLOWING LOCATIONS: 1. AT THE TOP OF AL EXTERIOR WINDOWS AND DOOR OPENINGS IN SUCH A MANNER AS TO BE LEAK -PROOF, EXCEPT THAT SELF -FLASHING WINDOWS HAVING CONTINUOUS LA OF NOT LESS HAN I 1/81NCH OVER THE SHEATHING MATERIAL AROUND THE PERIMETER OF THE OPENING. INCLUDING CORNERS, DO NOT REQUIRE ADDITIONAL CMU OPTION: SEAL FROM FACE OF BLOCK WALL EDGE TO FLASHING; JAMB FLASHING MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED BY THE BUILDING OFFICIAL. FRAME EDGE OF WINDOW WITH DRYLOCK SEALANT 2. AT THE INTERSECTON OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPIN 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR?ORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAMED CONSTRUCTION. 6. AT WALL AND ROOF INTERSECTIONS. EXTERIOR D O 2x4 GROSS -BRACING g RIDGE 20'-0" MAX 7 L4111 III Ilion NOUN LVA LVI III MEN O R &WINDOW FLASHING r i r EXISTING SUNROOM r i i r i TOP/BOTTOM CHORD GABLE ` TEND BRACING - 4&" O,C. MAX FOR THE FIRST 4 ROW5 OF TRUSSES (MIN 2X4 J WP GF w EXISTING MASTER BED 1 CONT, BOTTOM CHORD BRACING 4'x4" MIN.) s 10'-0" MAX. SEE TRUSS SYSTEM ENGINEERING DRAWINGS FOR ANY ADDITIONAL BRACING OR CROSS BRACING REQUIREMENTS REQ. MINIMUM TRUSS BRACING /1 0 PROVIDE MINIMUM 16" 26 GA VALLEY FLASHING o AT ALL ROOF CHANGES AND SIDE WALL AREAS o PER FBC 101.2.5 /R103.1.5. 103.8., W3.2 AND 905 0 PLACE ROOF CEMENT COATING AT ROOF DECKS o ° EDGES OF FLASHING AND ALL LAPS. NAIL FLASHING °` ° WITH 1 1/2" ROOF NAILS 12" CC 0 0 0 0 o ° 0 0 0 o ° 0 0 0 0 o SIDE WALLS OR CHIMNE' o ° o ° MINIMUM &"XS" 26 GA ANGLE FL o OR STEP FLASHING, SEE NOTE s 0 ROOF DECK AT SIDE WALLS TYPICAL ROOF FLASHING DETAIL NOT TO SCALE EXISTING/ r MASTER BA i GENERAL LOADS TYPE OF LOAD LIGHTING LOAD 16B SQ FT X 3VA 2304 OUTLETS 1 CIRCUITS X [50 VA 1260 TOTAL VA 3564 CONVERT VA TO AMPS 3564 DIVIDED BY 240 VOLTS • 15 AMPS STEP #3 ELECTRICAL LECzEND 110 V SWITCH u GROUND FAULT ® RECEPTACLE ILO v EXTERIOR WALL LIGHT WP 110 V 0 WATERPROOF �J OUTLET CEILING FAN IIOV LIGHT CAN BE CEILING O OR WALL (TYP) ELECTRICAL PANEL FLUORESCENT G.D.O. GARAGE DOOR FIXTURE OUTLET ■ �3.0.�.. GARAGE DOOR BUTTOM GENERAL ELECTRICAL NOTES FOR ADDITIONS: EXISTING STRUCTURE ELECTRICAL SERVICE WILL HAVE TO BE INSPECTED BY ELECTRICAL CONTRACTOR PRIOR TO THE ADDITION ELECTRICAL WORK BEING STARTED. IF THE EXISTING SERVICE CAN NOT HANDLE LOAD FROM THE NEW ADDITION THE SERVICE WILL HAVE TO BE UPGRADED TO MEET LOCAL AND STATE OF FLORIDA BUILDING CODES. ELECTR I C,4L FLAN J 1/A" = 11 O II WP GF i TO SWITCH AT / FRONT DOOR OF HOUSE I I I 1 I N III U c*1 Cn 4 �z o �0-4 or u- z cp U V Lu CV If) 0-4 ul Q Cf) U w z Q LL- A CA Q m m 6► 71 V7 c±l r— r an '� � ��(P cUW� 61W m ' c cCl m Mm t®1 z u-X L� l -C Z 9) `° d 0 m m _Z . ' Lu N ClU C ` Ln V co -0 �( o � w LL-1 � w 111 O CA -S in 0 W N N Q7 N C O 0 11.1 Q 0 O nnl VJ 0— z QUO Vl v, r O � � LIVING CLOSET 105 }=ORCII-I 41 GARAGE 4 STORAGE 622 ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS d 11 r u9, TOTAL �(08 RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 31296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION 3 OF 3 ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 160g OF THE FLORIDA BUILDING CODE 2020 -1 TH EDITION AND ASCE 1-16 FOR 139 MPH WIND ZONE RISK CATEGORY 11 AND THE ENTIRE -1 ARKAY # 20212 2020 BUILDING CODE RESIDENTIAL TH EDITION