Loading...
HomeMy WebLinkAbout7321 Gall BlvdO SYMBOL RELIABLE MODEL F1 FR-56 STANDARD COVERAGE QUICK RESPONSE UPRIGHT (NO ESCUTCHEON) SIN# RA1425 SPRINKLER LEGEND SYMBOL COUNT K-FACTOR SIN NPT DESCRIPTION O 20 5.6 RA1425 }" RELIABLE F7 FR56 OR BRASS UPRIGHT FIRE SPRINKLER HEAD 155° 20 TOTAL HEADS DENOTES EXISTING FIRE SPRINKLER PIPE TO DEMO - - - - - - - - DENOTES EXISTING FIRE SPRINKLER PIPE TO REMAIN DENOTES NEW FIRE SPRINKLER PIPE DENOTES CONNECTION POINTTO EXISTING FIRE SPRINKLER SYSTEM I SPRINKLER LEGEND STEEL EAR)OIST CAD PLATED FERROUS ALL THREAD ROD SEE MINIMUM SIZE RE UIREMENTS BELCW NOTE' BULK HANGER MATERIAL HAS BEEN SENTTO THE,OBSITE. FIELDCUT HANGEREAS NECESSARY. ALLTHaEAD ROD SIZES PIPE SIZES' 4"-ROD SIZE=3IB" PIPES IZES S" 8" -ROD SIZE = 12" PIPE SUPPORT - TYPE S01 TOP BEAM CLAMP W/ RING HANGER \aie"uoPUTE lROUSATR uulsgcuv�\` IPE PIPE SUPPORT SAMMY EXPRESS FOR STEEL W/ RING HANGER HANGER SPACING TABLE PIPE SIZE SCH. 10-40 1" 1 4" 1 Z" 2" 2 z" 3" 4" 6" 8" MAXIMUM HANGER SPACING 12'-0" 12'-0" 15'-0" 15'-0" 15-0" 15'-0" 15'-0" 15'-0" 15'-0" CPVC (IF APPLICABLE) 1" 1 " 1z' 2" 212" 3" 4" 6" 8" MAXIMUM HANGER SPACING 6'-0" 6'-6" 7'-0" 8'-0" 9'-0" 10'-0" 10'-0" NA NA I HANGER DETAIL �BMSS UPRIGHT TYPICAL SPRIGGED UPRIGHT KEYNOTE LEGEND ITEM DESCRIPTION 1 INSTALL NEW UPRIGHT SPRINKLER WITHIN 12" OF DECK. 2 PLUG EXISTING SPRINKLER OUTLET. 3 REMOVE DROP PIECE AND RAISE ALL PIPE TO SAME ELEVATION AS 4" MAIN EXISTING DRAIN FIRE SPRINKLER PLAN i �lq ? i SCALE: 1 /4" = V-0" SCALE 1 /4"=V-0" FIRE SPRINKLER DRAWING LEGEND SYMBOL DESCRIPTION 3" F— PIPE SIZE 10-6 IF PIPE LENGTH IN FEET -INCHES O HYDRAULIC REFERENCE POINTS E1B Q ELEVATION BELOW TOP OF STEEL L g_gJ ELEVATION ABOVE FINISHED LFOOR + (TOS 20-0) ELEVATION OF TOP OF STEEL p®— CEILING HEIGHT _7 DENOTES HANGER LOCATION 0 Up 1 x 1_D DENOTES RISE UP OR DOWN STANDARD GROOVED COUPLING © FIRELOCK GROOVED COUPLING �— PIPING CAP _E PIPING PLUG ® FIRE SPRINKLER RISER LOCATION # L01 LINE TAG (IF STOCK LISTED) MAIN TAG (IF STOCK LISTED) BASIC PIPE & FITTING MATERIAL REQUIREMENTS MINIMUM PIPE SCHEDULE FOR WELD/GROOVED/PLAIN END PIPE SCH. 7(DYNAFLOW, ETC.) BLACK STEEL PIPE SCH. 10 GALVANIZED PIPE SCH. 40 SEAMLESS SCH. 80 SHOP PAINTED CPVC MINIMUM PIPE SCHEDULE FORTHREADED PIPING: THREADABLE LIGHTWALL BLACK STEEL PIPE SCH. 40 GALVANIZED PIPE SCH. 80 SEAMLESS SHOP PAINTED FITTINGS GROOVED (STANDARD TAKEOUT) C.I. SCREWED GROOVED (SHORT RADIUS) D.I. SCREWED GROOVED COUPLINGS (RIGID) M.I. SCREWED (BLACK) GROOVED COUPLINGS (FLEXIBLE) M.I. SCREWED (GALV) WELDED OUTLETS FLANGED 125# MECHANICAL TEES FLANGED 250# CPVC HANGER MATERIAL STANDARD LOOP HANGER RINGS CLEVIS HANGERS REQUIRED ALL THREAD ROD TO BE BLACK ALL THREAD ROD TO BE CAD PLATED STAINLESS HANGER MATERIAL REQUIRED MATERIAL REQUIREMENTS DOMESTIC MATERIAL ONLY DOMESTIC OR FOREIGN MATERIAL ACCEPTABLE MATERIALTO MEETTHE MINIMUM REQUIREMENTS OF NFPA 13 MATERIAL TO BE UL LISTED AT A MINIMUM MATERIAL TO BE UL LISTED & FM APPROVED DRAIN PIPE & FITTINGS TO BE GALVANIZED GALVANIZED PIPE & FITTINGS REQUIRED FOR EXTERIOR WALL PENETRATIONS & EXTERIOR PIPING RUNS GENERAL NOTES DATE I BY REV I DESCRIPTION SCOPE OF WORK: TO DESIGN AND RETROFIT THE FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13, 2019, IN ACCORDANCE WITH FFPC 8TH ED. AND LOCAL AUTHORITY. BUILDING HAS AN OPERATIONAL FIRE SPRINKLER SYSTEM. WORK CONSISTS OF RAISING PIPE TO DECK AND INSTALLING NEW UPRIGHT SPRINKLERS TO PROTECT ROOM LAYOUT, AS SHOWN ON PLANS. NAME OF OWNER: HOBBY LOBBY AREA OF WORK: 1,850 SQ. FT. 1. ALL UNDERGROUND PIPING IS EXISTING TO REMAIN AS IS UNDISTURBED. 2. 1" TO 2" PIPING MAY BE BLACK SCHEDULE 40 THREADED AND JOINED BY DUCTILE IRON FITTINGS AND COUPLINGS. 3. 14" TO 6" PIPING MAY BE SCHEDULE 10 ROLL AHJ APP. GROOVED AND JOINED BY GROOVE TYPE FITTINGS. 4. ALL HANGERS AND TRAPEZE ASSEMBLIES SHALL UTILIZE UUFM LISTED COMPONENTS AND COMPLY WITH NFPA 13 REQUIREMENTS. 5, ALL CONTROL VALVES ARE EXISTING TO REMAIN AS IS UNDISTURBED. 6. IT IS THE RESPONSIBILITY OF THE OWNER OF THE PROTECTED PROPERTY OR THEIR AUTHORIZED AGENT TO PROVIDE PYE-BARKER FIRE & SAFETY, LLC WITH ANY KNOWLEDGE THAT THE WATER SUPPLY MIGHT BE CONTAMINATED WITH OR CONDUCIVE TO THE DEVELOPMENT OF MICROBIOLOGICALLY INFLUENCED CORROSION (MIC), INCLUDING AS REQUIRED BY NFPA 13. FAILURE TO IDENTIFY ADVERSE WATER QUALITY ISSUES MAY AFFECT THE FIRE PROTECTION SYSTEM AND VOID ANY MANUFACTURER OR INSTALLER Q WARRANTIES. co ui 7. MODIFICATIONS DO NOT INCREASE THE HYDRAULIC DEMAND OF THE EXISTING SYSTEM, tk C3 id NO NEW HYDRAULIC CALCULATIONS ARE INCLUDED. uj w 6d5 LL. EXI STI N G HYDRAULIC CALC PLATE z O Lu U QmN UU n �co m E W -� Q mm O O o p o of u� m LL 1u-1 oO zw LLLL .;U Q- u Of °-�� unn x To- z p 0.) U r4l,__ � Q o Cory � Jo 00 m ILL —� _jLo 0J J�_jcco co = CM O w = N z Q r oc w J z oc r W ryoo U w O HOBBY LOBBY CONTRACT NO. 1-2-4707-16-24 APPROVAL PASCO COUNTY DESIGNER KRW SCALE AS NOTED DATE 10 - 4 - 2024 FP1 NORTH