HomeMy WebLinkAbout7471 Gall Blvd (3)rlace K. A placard shall be conspicuously placed near each Class K extinguisher that states that the fire protection system shall be activated prior to using the fire extinguisher. Owners Responsibility: Safety Set Positioning System to be installed on all wheeled appliances. Safety -Set is designed to return caster -mounted kitchen equipment to a specific location after cleaning or maintenance. Scope of Work for fire suppression system: Complete final hook up of pre -piped CaptiveAire Hood. Shut -Downs and electrician responsibilities: All Electric and Gas cooking equipment under the kitchen hood and any outlets shall shut off upon fire suppression system actuation. Make Up Air/supply shall shutdown upon fire suppression system actuation. Exhaust fan operation to follow hood manufacturer specification. Pre -Engineered Fire Suppression System Shall be connected to the fire alarm. (if any). Local alarm (horn/strobe or bell) may be required by the Authority Having Jurisdiction. Manual actuation device (push station) shall be located at the means of egress or at the location acceptable to the AHJ and installed at 42"-48" above the floor. The manual actuation device shall clearly identify the hazard protected. New CaptiveAire SP-3 12 - Gallon UL-300 Compliant Wet Chemical Fire Suppression System FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. OL—F OL—F OL—F OL—F 85.0000 OL— F b' 21. 0" ---18.0000 32.0000 OL-F OL-F 32.0000 " 21. 0" 32.0000 OL-F OL-F TANK OVERLAPPING COVERAGE Installation shall be done in accordance with: 2023 FFPC 8th ed., NFPA 96 2021 ed., NFPA 17A 2021 ed., UL-300 standard, FBC 8th ed., NFPA 1 2021 ed., Florida State Statue 633-Rule 4A-21, NFPA 101 2021 ed., NFPA 72 2019 ed., NFPA 70 2020 ed. > 21. DpL—F I OL—F 51.6250 21. 0" LN 21. 23.2500 1" OL-F OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. Legend - Fire Cabinet Tank System 1 4 Gallon Tank 2 Primary Actuator Release 3 Secondary Actuator Release 4 Pressure Supervision Switch 5 Primary Hose Assembly 6 Secondary Hose Assembly 7 Remote Manual Actuation Device - SYSTEM REQUIRES A MINIMUM OF 7 FT OF - EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIAI EACH 90 DEGREE ELBOW ADDS 1.3 FT OF EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS OL—F S K FIVE ClUISHHF_ _11EP. SI_11*T Tank SP-3 12-Gal System: Hood sizes: 3 - 7' 0" 1 & 2-11'0" Plenum: Single bank Amount of Ducts and Size: 3 - 12" Dia., 2 - 18" Dia., 1 - 16" Dia. Length of supply Line Less than 30' Detection: 2 - Firestat Heat Detectors 3600 F Number of Flow Points Available in System = 60 Number of Flow Points Used in System = 56 Each nozzle (OL-F) uses 4 flow points. All pipe inside of the hood is 3/8 and 7 conduit 1 /2" used and all penetrations sealed with UL listed device or welded. All Pipe & Fittings and nozzles to be installed in accordance with UL 300 & manufacture's specs. All Protected Cooking Appliances Under the Hood Shall be UL Listed. ALL WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS REVIEW DATE '-)- °2- CITY OF ZEPHYRHILLS FIRE AND LIFE SAFETY EXAMINER 6P �SS1 ,H7f Clot( bjO «. FIRE SUPPRESSION SYSTEM Scale: N.T.S in J2-2 BREAK Ir EFORE INSERTING INTO 1!4 MI (.111116161 I Firestat Details CARE PROTECTIDN SENSOR INSTALLATIDN NOTES: One Sensor per Riser Multiple Sensors Wired in Parallel Wire Both Black Wires to One Lead, Both White Sensor may be installed on inside or outside of When installed in duct, install on opposite side 1/2" NPT Quik Seal (Adapter Body) Part # 32-00002----\ I Cf IVY Ul I If C J 1,U 1. 12-F28021-005360 (Normally Open, Close on rise @ 360°F) OR Fenwal Fire Stat 12-G28021-005500 (Normally Open, Close on rise @ 500°F) I/ if" uuiK peal (Gasket: Part # 32-00002 Wires to Second quick seal. When of quick seal, or Lead installed as shown in riser, install as with access door shown for sensor f or cleanability. 1/ C Part access from hood. Grease Duct (External Surf ace) NPT Quk Seal unIn nnnnll Quik Seal Clock #32-00002 Washer) Extension Ring 59361-1/2 ,xNOTEi EXTENSION RING TO BE TACK WELDED TO DUCT OR RISER Extension 100-BW Ring Cover FIRE SUPPRESSION SYSTEM Scale: N.T.S Pull Station Details ELECTRIC WET CHEMICAL (EWC) SPECIFICATION THE ELECTRIC WET CHEMICAL (EWC) FIRE SUPPRESSION SYSTEM IS A HYBRID FIRE SUPPRESSION SYSTEM FOR USE IN COMMERCIAL KITCHENS. THE CORE EWC MICROPROCESSOR -BASED CONTROL BOARD, PCBCORE BOARD, IS ETL LISTED UNDER REPORT NUMBER 101196419NYM-001 TO THE UL STANDARD 864 AND CAN/ULC-S527-11. THE COREPCB IS DESIGNED TO CONTROL A 24VDC-BASED, LISTED UL 300 WET CHEMICAL RESTAURANT FIRE SUPPRESSION SYSTEM. THE COREPCB CONTROLS PROVIDE ALL NECESSARY MONITORING, TIMING AND SUPERVISION FUNCTIONS REQUIRED FOR THE RELIABLE OPERATION OF THE WET CHEMICAL FIRE SUPPRESSION SYSTEM. ALL DEVICES THAT ARE CRITICAL FOR PROPER OPERATION ARE SUPERVISED AND INCLUDE AN ELECTRIC THERMAL DETECTOR(S) AND MANUAL PULL STATION(S)/MANUAL ACTUATION DEVICE(S). THE COREPCB CONTROL BOARD ALSO SUPERVISES FAULTS WITHIN THE SYSTEM AND WILL ALERT THE USER OF SPECIFIC CONDITION. I W 3.2511 CORE PROTECTION HOOD FIRE SYSTEM "; LIFT HERE ELECTRIC WET CHEMICAL MANUAL ACTIVATION STATION DETAIL THE PUSH/PULL STATION IS A REMOTE MANUAL ACTIVATION DEVICE TO ACTIVATE THE FIRE SYSTEM. THIS REMOTE MANUAL ACTIVATION DEVICE (PUSH/PULL STATION) CONTAINS ONE SET OF NORMALLY OPEN CONTACTS, AND MOUNTS TO ANY STANDARD JUNCTION BOX. WHEN THE FRONT BUTTON IS PRESSED, THE ELECTRICAL CONNECTION TO THE FIRE SYSTEM IS COMPLETED, THUS ACTIVATING THE FIRE SYSTEM. THE REMOTE MANUAL ACTIVATION (PUSH/PULL STATION) SHOULD BE MOUNTED AT THE POINT OF EGRESS AT 42-48 ABOVE THE FLOOR.. LOCATION OF THE MANUAL PULL STATION SHOULD BE DETERMINED BY AHJ. TO RESET, TWIST THE PUSH-BUTTON CLOCKWISE UNTIL THE INTERNAL LATCH IS RELEASED. THE CLEAR PROTECTIVE COVER MUST BE INSTALLED TO PROTECT THE DEVICE FROM ACCIDENTAL ACTIVATIONS. THE COVER IS PROVIDED AS PART OF THE MANUAL ACTIVATION DEVICE. THE SYSTEM IS CAPABLE OF AUTOMATIC DETECTION AND ACTIVATION AND/OR REMOTE MANUAL ACTIVATION. THE DETECTION PORTION OF THE FIRE SUPPRESSION SYSTEM ALLOWS FOR AUTOMATIC DETECTION BY MEANS OF AN ELECTRIC THERMAL DETECTOR(S) LOCATED IN THE HOOD DUCT CONNECTION(S). A PUSH STATION / MANUAL ACTUATION DEVICE IS ALSO PROVIDED TO ALLOW FOR MANUAL ACTIVATION OF THE FIRE SYSTEM. WITH THE ELECTRIC THERMAL DETECTION, A BATTERY BACKUP SYSTEM IS PROVIDED. THE BACKUP BATTERY SYSTEM POWERS THE COREPCB BOARD CONTROLS INCLUDING THE AUTOMATIC DETECTION, PULL STATION/MANUAL ACTUATION DEVICE CIRCUITS, AS WELL AS SUPERVISES THOSE DEVICES AND ANY AUXILIARY SUPERVISORY EQUIPMENT IN THE EVENT OF A LOSS OF POWER TO THE BUILDING. UPON A FIRE CONDITION, THE ELECTRIC THERMAL DETECTOR CONTACTS WILL CLOSE AND SEND A SUPERVISED SIGNAL TO THE COREPCB BOARD. THE COREPCB BOARD THEN SENDS A SIGNAL TO THE 24VDC REGULATED RELEASE SOLENOID, WHICH WILL PUNCTURE A PRECHARGED WET CHEMICAL AGENT TANK PROPELLING AGENT INTO THE DISTRIBUTION LINES TOWARDS THE DISCHARGE NOZZLES BREAK� WIRE BEFOR INSERTING INTO TERMINA:Lz�� MINE ■ 2 MANUAL uATION DEVICE «, \FIRE SUPPRESSION SYSTEM Scale: N.T.S