HomeMy WebLinkAbout7600 Gall Blvd (3)EXISTING OVERHEAD FUEL CANOPY EXISTING CONCRETE EXISTING ACCESSIBLE LOADING AREA EXISTING SITE AERIAL SCALE 1'=60' 1. MAXIMUM BOLLARD SPACING IS 5' ON CENTER 2. CONCRETE TO BE 4,000 PSI MIN. UNCONFINED COMPRESSIVE STRENGTH. 3. REINFORCING STEEL CONFORMS TO ASTM A615 GRADE 60. 4. BOLLARD PIPE IS ASTM A53, TYPE E, GRADE B OR A500 GRADE B/C. 5. PROVIDE HIGH —DENSITY POLYETHYLENE (HDPE) BOLLARD COVER. COVER TO BE IDEALSHIELD (OR APPROVED EQUAL) 1/8" THICK, BROWN (PQ— 440C), 6" PIPE FIT, DOME TOP, 48" TALL. 6. DO NOT FILL BOLLARD PIPE WITH CONCRETE. TEMPORARILY SEAL BOTTOM AS NECESSARY TO PREVENT CONCRETE INTRUSION WHILE POURING. 7. USE SONOTUBE IN SANDY OR OTHER SOILS THAT MIGHT CAVE IN. 8. DIMENSIONS IN PARENTHESIS ARE NOMINAL. 9. COLD JOINT ACCEPTABLE THIS LINE FOR NEW INSTALLATIONS IN MONOLITHIC POUR CONCRETE PAVEMENT. 10. SLOPE TOP OF CONCRETE AWAY FROM BOLLARD 1/4" FROM PIPE TO EDGE OF DRILLED SHAFT OR CAP. 11. INCREASE DEPTH OF CAISSON AND BOLLARD PIPE TO MEET LOCAL JURISDICTION MIN. FROST DEPTH REQUIREMENT. 12. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY NO UTILITY CONFLICTS EXIST WHERE BOLLARDS ARE TO BE INSTALLED, PRIOR TO INSTALLATION. DESIGN SPECIFICATIONS: ASTM F3016-19 CONDITION DESIGNATION S20 at0 o 0MEN wu GENERAL NOTES; 1. EXISTING SITE FEATURES SHOWN ON THIS PLAN ARE BASED OFF OF AERIAL IMAGERY OR BEST AVAILABLE INFORMATION AND SHALL BE VIEWED AS APPROXIMATE. CONTRACTOR SHALL VERIFY MEASUREMENTS IN THE FIELD AND CONTACT DEVELOPMENT SERVICES GROUP (757-908-2372) IF ANY DISCREPANCIES ARE FOUND PRIOR TO THE START OF CONSTRUCTION. 2. CONTRACTOR SHALL PATCH AND REPAIR EXISTING PAVEMENT AS REQUIRED TO RETURN SURFACE TO EXISTING CONDITION. 3. EXISTING CROSS SLOPES AND EXISTING ACCESSIBILITY COMPLIANCE HAS NOT BEEN VERIFIED AND IS OUTSIDE THE SCOPE OF THE PROPOSED IMPROVEMENTS. 4. CONTRACTOR SHALL CALL 811 TO REQUEST THAT THE APPROXIMATE LOCATION OF BURIED UTILITIES ARE MARKED PRIOR TO THE START OF CONSTRUCTION. PRIVATE UTILITY LOCATION MAY BE REQUIRED FOR ON -SITE UTILITIES. CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL REGULATIONS REGARDING UNDERGROUND EXCAVATION. 5. BOLLARDS SHALL BE PLACED IN THE PAVEMENT DIRECTLY IN FRONT OF THE BUILDING WHEN A VEHICLE HAS THE POTENTIAL TO PIN A PEDESTRIAN AGAINST THE BUILDING. 6. EXISTING WHEEL STOPS CAN BE REMOVED FROM PARKING SPACES WHERE BOLLARDS ARE ADDED. 7. IF THE DEPTH OF THE EXISTING PARKING SPACES NO LONGER MEET THE REQUIREMENTS OF THE LOCAL ORDINANCE, THE CONTRACTOR SHALL RE -STRIPE THE EXISTING PARKING SPACES TO MEET MINIMUM STANDARDS. 8. ALL IMPROVEMENTS SHALL MEET THE CURRENT STATE BUILDING CODE. SEE NOTE 10 SEE NOTE 9 �6tl) ;N N A A 0- 00 SE TION A -A N.T.S S20 PIPE BOLLARD LAYOUT LEGEND: 00 d- HDPE BOLLARD COVER PARKING STRIPE BOLLARD LAYOUT N.T.S. 0 0 — PROPOSED BOLLARD BOLLARDS LINED UP WITH RAMP LANDING (LANDING WIDTH WILL VARY, MAINTAIN A MINIMUM 4.5' O.C. SPACING, MAXIMUM 5.0' SPACING.) 3-1/2" 4„ 9„ 4„ 3-1 3" G 24" 18" #3 REBAR, TYP. 3" C I_ 24" _I 6" SCHEDULE 80 PIPE BOLLARD (DO NOT FILL WITH CONCRETE) DRILLED SHAFT CONCRETE FOUNDATION CONCRETE CURB SIDEWALK PAVEMENT DEEP MOUNT S20 BOLLARD IN CONCRETE PAVING N.T.S. CONCRETE PAVEMENT ASPHALT PAVEMENT ro� PROPOSED BOLLARD (TYP. OF 50) (0-) EXISTING BOLLARD f CAP REINFORCING DETAILS N.T.S. HDPE BOLLARD COVER 2" I O IM 6" SCHEDULE 80 PIPE BOLLARD (DO NOT FILL WITH CONCRETE) DRILLED SHAFT CONCRETE FOUNDATION CONCRETE CURB SIDEWALK PAVEMENT COLD JOINT ACCEPTABLE MOUNT S20 BOLLARD ASPHALT PAVING N.T.S. REVIEW DATE DETAIL A CITY OF 2EPHYRHIL s FIRE AND LIFE SAFETY E:XAMIN N.T.S. STORE FRONT BOLLARD DETAIL N.T.S. DRAWING SCALE 10 0 10 20 SCALE: 1'=10' W Q 0 z 0 f-- C) cn w 0 > w GaryDigitally signed by A Gary A Franks Frank Date: 202401.1 9 S 19:52:05 -05'00' 2:�f1 N N A.� �a Z C :�'• •yam: �, bb • .... . • o�\ ''//f f�! ► i�i Ip � ����\ DESIGNED BY: DRAWN BY: JS REVIEWED BY: GF CA W v a OC C� O L0 L V� oc CL z 0 J o � O z J Jm m �i g coLd x U OJ J J z � _J J uj Q = Ld a. W o o = a- co h a- N CL—loO SHEET