Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7631 Gall Blvd (38)
BDA SYSTEMS CO. PH: 9500 NW 12thS 1(855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO. dd GONSULTINO GROUP, INC. CA LICENSE #31 0315 JOR®E J. SALOA D, P..E. #531300 2001 Y1ZEWELL CIRCLE #ISCSI ORLANDO, FL 38937 PROFESSIONAL SEAL: \11II11i����/ ��\\\ -1 G N 3 RG• fi/> o. 53600 i 0 10/11NAL 1111 \\\\\ #PG00061851 PROJECT INFORMATION: ui M *cn /— L.L_ U) u a O ry �C >" L u LU 0 aLL> �Qm c) Q I(D mv- M CL f` REVISION: SCOPE OF WORK BDA: PROVIDE RADIO COVERAGE ABOVE THE MINIMUM LEVELS FOR FIRE DEPARTMENTS IN THE AREAS REQUESTED BY THE AHJ. THIS WILL BE DONE BY THE INSTALLATION OF 1 BDA. THE SIGNAL WILL BE DISTRIBUTED THROUGHOUT THE BUILDING INTO THE DISTRIBUTION ANTENNAS BY PLENUM CABLES. SYSTEM CABLING WILL BE INSTALLED SECURED TO CEILING OR WALLS AND SPLITTERS IN PUC BOXES. SCOPE OF WORK BDA: PROVIDE RADIO COVERAGE ABOVE THE MINIMUM LEVELS FOR FIRE DEPARTMENTS IN THE AREAS REQUESTED BY THE AHJ. THIS WILL BE DONE BY THE INSTALLATION OF 1 BDA. THE SIGNAL WILL BE DISTRIBUTED THROUGHOUT THE BUILDING INTO THE DISTRIBUTION ANTENNAS BY PLENUM CABLES. SYSTEM CABLING WILL BE INSTALLED SECURED TO CEILING OR WALLS AND SPLITTERS IN EMT BOXES. CODES IN EFFECT AT TIME OF THIS PLAN SUBMISSION CODES IN EFFECT AT THE TIME OF THIS PLAN SUBMISSION: + NFPA 72, 2016 EDITION • NFPA 1221, 2016 EDITION • NFPA 70, 2017 EDITION, 'NATIONAL ELECTRICAL CODE' ALL COAX CABLES USED IN THIS DESIGN ARE PLENUM RATED, EXCEPT FOR THE DONOR ANTENNA CABLES ON THE ROOF. ALL CABLES WILL BE INSTALLED WITH SPLITTERS INSIDE EMT CONDUIT. CABLES FOR DISTRIBUTION ANTENNAS HAVE LEVEL 1 SURVIVABILITY. GENERAL NOTES 1. DONOR ANTENNA MAST TO BE GROUNDED TO 6 AWG CONDUCTOR. IF SUITABLE GROUNDING BAR MUST BE PROVIDED BY ELECTRICAL CONTRACTOR. 2. THE BDA ENCLOSURE WILL BE LABELED AS INDICATED BELOW:SERVICED BY: VENDOR NAME AND CONTACT CIRCUIT BREAKER: PANEL LOCATION AND # 3. BATTERIES NEED TO HAVE MANUFACTURER AND INSTALLATION DATE SPECIFIED. 4. ALL NEMA 4/4X BOXES WILL BE IN FIRE ENGINE RED WITH A LOCKING MECHANISM. BOXES SHALL BE PENETRATED FROM UNDERNEATH. 5. CIRCUIT TO THE BDA SYSTEM WILL HAVE A DEDICATED CIRCUIT. 6. ANY BDA WILL PLUG INTO A SINGLE NEMA TWIST-LOCK/OUTLET PLUG. 7. THE CIRCUIT PANEL WILL BE LABELED ON THE BDA CABINET. 8. THE ELECTRIC PANEL ID WILL BE LABELED IN THE BDA CABINET. 9. THE CIRCUIT WITHIN THAT PANEL WILL BE IDENTIFIED AT THE BDA CABINET, 10. THE CIRCUIT WILL BE LABELED IN RED'BDA' IN THE ELECTRIC PANEL. 11. THE CIRCUIT WILL HAVE LOCK, WITH A SET SCREW OR PADLOCK, THE USE OF AN ALARM CIRCUIT LOOKOUT IS ALLOWED, FOR THE CIRCUIT PROTECTING THE BDA. 12. THE CIRCUIT WILL BE DEDICATED AND NO OTHER SERVICES WILL USE THE SAME THE CIRCUIT. 13. THE DEDICATED PANEL WILL NOT HINDER SIGNALS TO THE FACP UPON MALFUNCTION. 14. BATTERIES ARE TO BE MARKED WITH DATE OF MANUFACTURING AND DATE OF INSTALLATION. 15. CABLE SPECS ONLY PLENUM RATED CABLE SHALL BE USED TO CONNECT ANTENNAS TO THE SYSTEM. 16. FIRE COMMAND ROOM OR AN APPROVED LOCATION WILL BE USED TO PLACE BDA. DESIGN SUMMARY 1. THE DONOR ANTENNA AZIMUTH MUST BE DEFINED BY THE AHJ. 2. THE REPEATER, BATTERY BACKUP, DEDICATED ANNUNCIATOR AND FACP WILL BE THE REPEATER, BATTERY BACKUP, DEDICATED ANNUNCIATOR AND FACP WILL BE LOCATED WITHIN 2-HOUR RATED ROOM. 3. BDA IS COMPATIBLE WITH THE P25 DIGITAL SYSTEM AND ALSO IS DESIGNED TO ALLOW FOR 700 MHz 4. CABLES FOR THE DISTRIBUTION ANTENNAS WILL HAVE LEVEL 01 PATHWAY SURVIVABILITY. 5. ALL SPLITTERS WILL BE WITHIN EMT CONDUIT BOXES. 6. AS PER NFPA 1221: 9.6.12, ALL COMPONENTS OF THE SYSTEM HAVE AT LEAST TWO INDEPENDENT AND RELIABLE POWER SOURCES COMPLIANT TO 9.6.12.1 (DEDICATED BRANCH CIRCUIT) AND 9.6.12.2 (BATTERY BACKUP WITH AT LEAST 12-HOUR OF 100 PERCENT SYSTEM OPERATION ON CAPACITY). 7. MONITORING OF THE INTEGRITY OF THE CIRCUITS SHALL BE COMPLIANT WITH NFPA 72,10.6.9 (MONITORING AND INTEGRITY OF POWER SUPPLIES) AND NFPA: 1121: 9.6.13 WITH THE REQUIRED AUTOMATIC SUPERVISORY SIGNALS FOR MALFUNCTIONS OF THE SYSTEM THAT ARE ANNUNCIATED BY THE FIRE ALARM SYSTEM IN ACCORDANCE WITH NFPA 72 2016. 8. AS PER NFPA 9.6.10.2 SYSTEM UPGRADE ABLE TO ALLOW FOR INSTANCES WHERE THE JURISDICTION CHANGES OR ADDS SYSTEM FREQUENCIES TO MAINTAIN RADIO SYSTEM COVERAGE AS IT WAS ORIGINALLY DESIGNED. 9. ALL SYSTEM ANTENNAS WILL BE CAPABLE OF TRANSMIT & RECEIVE OF FIRE FREQUENCIES. 10. CABLING MUST NOT EXCEED MANUFACTURED SPECIFIED BEND RADIUS. 11. ALL EQUIPMENT WILL BE PROPERLY GROUNDED PER SPEC. SYSTEM MONITORING DEDICATED PANEL DIAGRAM 1. SYSTEM MONITORING FIRE ALARM SYSTEM THE PUBLIC SAFETY RADIO COMMUNICATIONS ENHANCEMENT SYSTEM SHALL INCLUDE AUTOMATIC SUPERVISORY AND SUPERVISORY SIGNALS FOR MALFUNCTIONS OF THE SIGNAL BOOSTER(S) AND POWER SUPPLY(IES) THAT ARE ANNUNCIATED BY THE FIRE ALARM SYSTEM ANNUNCIATOR AND COMPLY WITH THE FOLLOWING: SYSTEM AND SIGNAL BOOSTER SUPERVISORY SIGNALS SHALL BDA LOSES PANEL ALARM MAIN PANEL INCLUDE: OF NORMAL No BDA LOSS OF LOSS OF N C (1) BDA - DONOR ANTENNA MALFUNCTION AC POWER NORMAL AC POWER POWER (2) BDA - SIGNAL BOOSTER FAILURE SIGNAL BOOSTER FAILURE (3) POWER SUPPLY SUPERVISORY SIGNALS SHALL INCLUDE THE FOLLOWING FOR EACH SIGNAL BOOSTER: (A) BDA -LOSS OF NORMAL AC POWER ANNUNCIATOR BDA PANEL MAIN EL (B) BDA - FAILURE OF BATTERY CHARGER CHARGER ALARM BDA LOSS OF (C) BDA -LOW-BATTERY CAPACITY, ALARMING AT 70 PERCENT OF BATTERY CAPACITY FAILURE CHARGER NORMAL AC POWER 2. FIRE ALARM SYSTEM WILL BE INSTALLED BY A FIRE ALARM COMPANY IN IN A SEPARATE PERMIT. THE FAILURE LOCATION OF THE FIRE ALARM CONTROL PANEL (FACP) IS THE FIRE COMMAND CENTER WHERE ALSO AN ANNUNCIATOR WILL BE PLACED. THE DEDICATED PANEL WILL BE PLACED IN THE GROUND FLOOR FIRE BDA LOW ANNUNCIATOR PANEL ALARM RISER ROOM. DEDICATED PANEL SHALL BE CONNECTED TO THE MAIN FACP TO PROVIDE AUTOMATIC BATTERY ALARM LOW MAIN PANEL SUPERVISORY AND SUPERVISORY SIGNAL ANNUNCIATION IN THE FACP IN ACCORDANCE WITH NFPA 2016 CAPACITY BATTERY LOW BATTERY CAPACITY CAPACITY (1221:9.6.13 EDITION) 3. A DEDICATED MONITORING PANEL SHALL BE PROVIDED WITHIN THE EMERGENCY COMMAND CENTER TO ANNUNCIATE THE STATUS OF ALL SIGNAL BOOSTER LOCATIONS. THE MONITORING PANEL SHALL PROVIDE ANNUNCIATOR BDA DONOR PANEL ALARM MAIN PANEL VISUAL AND LABELED INDICATION OF THE FOLLOWING FOR EACH SIGNAL BOOSTER: ANTENNA DONOR DONOR - (1) BDA -LOSS OF NORMAL AC POWER MALFUNCTION ANTENNA ANTENNA (2) BDA -BATTERY CHARGER FAILURE MALFUNCTION MALFUNCTION (3) BDA -LOW-BATTERY CAPACITY (4) BDA -DONOR ANTENNA MALFUNCTION (5) BDA -SIGNAL BOOSTER FAILURE BDA SIGNAL ANNUNCIATOR PANEL ALARM MAIN PANEL BOOSTER SIGNAL SIGNAL AUXILIARY POWER FOR DEDICATED PANEL, SHALL BE SUPERVISED BY THE FACP AND MUST HAVE BATTERY BACK UP, FOR AT FAILURE BOOSTER BOOSTER FAILURE FAILURE LEAST THE SAME TIME AS PROVIDED TO THE RADIO SYSTEM, ANY SUPERVISORY CONDITION SHALL BE DISPLAYED AT THE LOCAL FIRE ALARM PANEL. STRUCTURAL METAL MEMBER IS NOT AVAILABLE WITHIN 20' OF ANTENNA MAST, A SUITABLE BATTERY CALCULATIONS POWER SUPPLY: AS PER NFPA 72, 2016 ED: 10.6.7.2.1 -THE SECONDARY POWER SUPPLY FOR THE TWO-WAY RADIO COMMUNICATION ENHANCEMENT SYSTEMS SHALL BE IN ACCORDANCE WITH 24.5.2.5.5. AS PER NFPA 72, 2016 ED: 24.5.2 -A STORAGE BATTERY DEDICATED TO THE SYSTEM WITH AT LEAST 24 HOURS AT 100 PERCENT OPERATION CAPACITY. AS PER NFPA 72, 2016 - 24.5.2 -TIME REQUIRED FOR BATTERY AT 100%%%0: 24 HOURS -PROVIDED BATTERY CAPACITY: 55 AH -POWER CONSUMPTION NEEDED FOR 24 HOURS IN BATTERY POWER ONLY: 2.08 A X 24 HOURS = 50AH -25 AH < 55 AH - THE BATTERY CAPACITY SURPASSES THE 24 HOURS REQUIREMENT. SEOUENCE OF OPERATIONS 1. BDA LOSS OF NORMAL AC POWER SHALL BE SUPERVISED AND A SUPERVISORY SHALL INDICATE AT THE ANNUNCIATOR AND MAIN FACP, WITH A MESSAGE AND/ OR AMBER LIGHT INDICATING SUPERVISORY CONDITION IN RADIO ENHANCEMENT SYSTEM (ON BATTERY). 2. BDA BATTERY CHARGER FAILURE SHALL BE SUPERVISED AND A SUPERVISORY SHALL INDICATE AT THE ANNUNCIATOR AND THE MAIN FACP, WITH A MESSAGE AND/ OR AMBER LIGHT INDICATING SUPERVISORY CONDITION IN RADIO ENHANCEMENT SYSTEM (CHARGER FAILURE). 3. BDA LOW BATTERY CAPACITY SHALL BE SUPERVISED AND A SUPERVISORY SHALL BDA LOW BATTERY CAPACITY SHALL BE SUPERVISED AND A SUPERVISORY SHALL INDICATE AT THE ANNUNCIATOR AND THE MAIN FACP, WITH A MESSAGE AND/ OR AMBER LIGHT INDICATING SUPERVISORY CONDITION IN RADIO ENHANCEMENT SYSTEM (LOW BATTERY) 4. BDA DONOR ANTENNA MALFUNCTION SHALL BE SUPERVISED AND SHALL INDICATE BDA DONOR ANTENNA MALFUNCTION SHALL BE SUPERVISED AND SHALL INDICATE AT THE ANNUNCIATOR AND MAIN FACP, WITH A MESSAGE AND/ OR AMBER LIGHT INDICATING SUPERVISORY CONDITION IN RADIO ENHANCEMENT SYSTEM (DONOR ANTENNA MALFUNCTION). 5. BDA SIGNAL BOOSTER SUPERVISORY SHALL BE SUPERVISED AND A SUPERVISORY SHALL INDICATE AT THE ANNUNCIATOR AND THE MAIN FACP, WITH A MESSAGE AND/ OR AMBER LIGHT INDICATING SUPERVISORY CONDITION IN RADIO ENHANCEMENT SYSTEM (SYSTEM COMPONENT MALFUNCTION), FREQUENCIES 1.700/ 800 MHZ CAPABLE PASCO COUNTY PUBLIC SAFETY. 2. DONOR ANTENNA WILL BE POINTED TO COORDINATES REQUESTED BY THE AHJ. 3. AS PER FLORIDA GUIDELINES, COMPLIANCE LEVELS ARE: - 95 DBM COVERAGE THROUGHOUT GENERAL AREAS. -95 DBM COVERAGE IN 100% OF CRITICAL AREAS (ELEVATOR SHAFTS, GENERATOR ROOMS, FIRE PUMP ROOMS, MECHANICAL ROOMS, ELEVATOR ROOMS, STAIR ENCLOSURES, UNDERGROUND GARAGES, UNDERGROUND ROOMS, FIRE COMMAND CENTERS, CORRIDORS AND OTHERS DEFINED BY THE AHJ). BDA SYSTEMS CO. PH: 9500 NW 12thST (855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO. JJ CONSULTING 13ROUP, INI3. DA LICKNii #31 030 JORGE J. SALGADO, P.E. #336[30 0401 TIZLWXLL DIROL6 #1sag ORLANDO,PL .MR37 PROFESSIONAL SEAL: ,���11t11111//��`/ pQ:��GENs * .53600 J ', 11 yipNAL ' 001111110 C� #PG00061851 PROJECT INFORMATION: �-- W `* M >" LL U) cfi 0 J � 0 = N J W o aQ LL m 0 _I o m c c0 REVISION: Link Budget Report Coupler Splitter Cable Other Other Summary Thru Loss Tap Loss Loss Sys Out Pwr Total DAS Gain/Los ntenna Gain * Antenna ERP Generic Generic Generic AirCell-Trilogy Imes microwave PolyPhaser Technical Antennas Total Pwr per Ch. Antenna ID Operator System ID 6dB 6dB 2-Way MR-AP6012J50-RD LMR-600 TSX-NFF TA-78-1 DIRECTIONAL DONO -6.10 dB -1.36 dB -3.02 dB -0.10 dB 4.00 dB Qty Subtotal (d8) Qty Subtotal (d6) City Subtotal (d6 Length feet g (feet) Length feet L gt (feet) Subtotal (dB) Qty Qty ubtot I (dB) a ( ) (dBm) dB ( ) (dBd) (dBm) ANT1013 Emergency Radio800 MHz - SMR - P25 - Sector NIA 1 -6.1 1 -1.36 1 -3.02 279.92 26.54 7.65 1 1 3.9 -71 66.46 -1.15 5.69 ANT1014 Emergency Radio8OO MHz - SMR - P25 - Sector N/A 2 -2.72 1 -3.02 493.05 26.54 -12.41 1 1 3.9 -71 66.75 -1.15 -5.4 ANT1015 Emergency Radio800 MHz - SMR - P25 - Sector N/A 2 -12.2 1 -3.02 131.45 26.54 -4.27 1 1 3.9 -71 64.78 -1.15 -7.37 ANT1016 Emergency Radio800 MHz - SMR - P25 - Sector N/A 1 -6.1 1 -1.36 1 -3.02 331.56 26.54 -8.75 1 1 3.9 -71 65.35 -1.15 -6.8 ANT1017 lEmergency Radio800 MHz - SMR - P25 - Sector N/A 2 -12.2 1 -3.02 122.29 26.54 -4.07 1 1 3.9 -71 64.98 -1.15 -7.17 ANT1018 Emergency Radio800 MHz - SMR - P25 - Sector N/A 1 -6.1 1 -1.36 1 -3.02 321.86 26.54 -8.54 1 1 3.9 -71 65.56 -1.15 -6.59 ANT1019 Emergency Radio 00 MHz - SMR - P25 - Sector N/A 1 -6.1 1 -1.36 1 -302 231.02 26.54 -6.6 1 1 3.9 -71 67.5 -1.15 -4.65 ANT1020 Emergency Radio800 MHz - SMR - P25 - Sector N/ 2 2.72 1 -3.02 431.14 26.54 -11.08 1 1 3.9 -71 68.07 -1.15 -4.08 Equipment List Report Type Manufacturer Model Description Inventor# Qty Antenna Technical Antennas TA-0727-1 Omnidirectional Indoor Dome Ceiling N/A 8 Indoor Omni Mount Antenna Antenna Technical Antennas TA-78-1 8dBi - Narrow Band Panel Antenna - 760- N/A 1 DIRECTIONAL 860 MHz - N-Female DONOR Cable AirCell-Trilogy MR-AP6012J50- Metal Raceway, 1/2", Red, Corrugated (6 N/A 1261.50 feet RD GHz), Jacketed CMP, Conforms to NFPA-262, UL-444 Canadian CSA 22.2 FT6 Cable Times Microwave LMR-240-3.28ft 50 Ohm - 3.28 ft LMR-240 Jumper Cable N/A 6 Systems Cable Times Microwave LMR-600 Flexible Low Loss Communications Coax - N/A 26.54 feet Systems Outdoor Application Connector AlrCell-Trilogy NMP01250 N Type, Male Connector for 1/2 AlrCell N/A 20 Plenum & In -Conduit Cables 50 Ohm Connector Times Microwave EZ-600-NMC-2-D N Male Straight Plug for LMR-600 Cable N/A 2 Systems Miscellaneous PolyPhaser TSX-NFF Ultra -low PIM, DC Black, N type RF Surge N/A 1 Protector, 698-2700MHz, FF Repeater Advanced RF PSR-78-9533-X 95 dB Gain Digital Dual -Band Channelized PSR-78- 1 Technologies Public Safety Repeater - 700 MHz / 800 MHz 9533-X (32 channels, 4 modes) - 4.3-10 Female Splitter Generic 2-Way 2-Way Sputter / Combiner - 0-6000 MHz N/A 1 Splitter lGeneric j6dB 16 dB Directional Coupler N/A 6 BDA SYSTEMS CO. PH:19500 NW 12thS (855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO, JJ CONSULTING GROUP, INC. GA LIORNAK #31 038 JORGE J. SALGADO, P.E. #6361313 2001 'nZKWELL DlROLB #teov ORLAN:DO. FL 32537 OESSI O `` SEAL: l 11///��� J. SALG, *'�Q ;•\C E N 0 ' 53600 STATE OF ' I111110 C#PG00061851 PROJECT INFORMATION: �- �.. j Lo co LL U 0 J Q > UJI 2 � N J LL j Q Q m Cfj � 0 Q J m M REVISION: r *- Y t ' Y ` ff, i GENERAL 1. THE PURPOSE OF THIS DOCUMENT IS TO PROVIDE THE REQUIRED STEPS FOR A COMPLETE INSTALLATION OF A DISTRIBUTED ANTENNA SYSTEM OPERATING ON THE LOCAL AHJ PUBLIC SAFETY FREQUENCIES. CONTRACTOR SHALL SUPERVISE AND COORDINATE AL WORK TO THE BEST OF HIS ABILITIES AND SKILLS. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION METHODS, TECHNIQUES, PROCEDURES, SEQUENCING AND COORDINATION OF THE WORK. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE FOLLOWING CODES, STANDARDS AND SUPPLEMENTS. THE MOST STRINGENT CODE WILL APPLY IN RESPECT TO DISCREPANCIES OR DIFFERENCES IN THE CODE REQUIREMENTS. AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION SPECIFICATIONS IEEE - INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS NEC - NATIONAL ELECTRIC DOE NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION UL - UNDERWRITERS LABORATORIES NSPC - NATIONAL STANDARD PLUMBING CODE IMC - INTERNATIONAL MECHANICAL CODE NFPA - NATIONAL FIRE PROTECTION ASSOCIATION OSHA - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION ANSI/TIA - TELECOMMUNICATIONS INDUSTRY ASSOCIATION 222-G STANDARD 3. ENGINEERED DRAWINGS SHOW AREAS OF WORK THAT MUST BE ACCOMPLISHED. INCIDENTAL WORK MAY ALSO BE REQUIRED IN AREAS NOT SHOWN IN DRAWINGS DUE TO UNFORESEEN CHANGES. WORK MUST BE PERFORMED WITH NO ADDITIONAL COST TO THE OWNER. 4. DO NOT SCALE DRAWINGS. 5. MINOR DEVIATIONS FROM THE DESIGN LAYOUT ARE ACCEPTABLE SO LONG AS THEY DO NOT HINDER THE OVERALL PERFORMANCE OF THE SYSTEM. OWNER MUST APPROVE ALL CHANGES PRIOR TO IMPLEMENTATION. 6. CONTRACTOR IS TO COMPLY WITH ALL APPLICABLE NOTES IN ALL RESPECTS. 7. ALL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENT TO BE USED IN CONDITIONS WHICH ARE NOT SPECIFICALLY SHOWN OTHER- WISE. 8. THE USE OF TRUE NORTH ON THE DRAWINGS IS MEANT TO IDENTIFY BEARINGS AT THE SITE. ANY DISCREPANCY MUST BE MADE KNOWN TO THE EN- GINEER TO CORRECT AND CONFIRM DESIGN BY THE CONTRACTOR. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND REGULATIONS, SUCH AS OSHA COMPLIANCE, DURING THE PROGRESS OF WORK. ENGI- NEER IS NOT RESPONSIBLE FOR THE SAFETY AND WELL BEING OF ANY PERSONNEL RELATED TO THE WORK. 10. CONTRACTOR AGREES TO INDEMNIFY AND HOLD THE DESIGN ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, 11. CONTRACTOR ASSUMES COMPLETE RESPONSIBILITY OF THE SECURITY OF THE SITE UNTIL COMPLETION OF CONSTRUCTION IN REGARDS TO THE SYSTEM, 12. CONTRACTOR IS RESPONSIBLE FOR PULLING THE BUILDING PERMIT WITH THE LOCAL JURISDICTION PRIOR TO WORK BEGINNING. 13. CONTRACTOR IS RESPONSIBLE FOR APPLICATION AND PAYMENT OF CONTRACTOR LICENSES, BOND AND INSURANCES. 14. ALL MATERIALS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 15. DESIGN ENGINEER IS NOT RESPONSIBLE FOR ANY CHANGES OR MISREPRESENTATION BY A MANUFACTURER ON THE SPEC SHEETS. 16. ALL EQUIPMENT SHALL BE INSTALLED LEVEL AND PLUMB. 17. BY SUBMITTING A BID FOR WORK ON THIS PROJECT CONTRACTOR ACKNOWLEDGES A FULL UNDERSTANDING OF THE CONSTRUCTION DOCU- MENTS, VISITED THE SITE AND IS FAMILIAR WITH THE CONDITIONS AND EXPECTATIONS OF THE WORK TO BE PERFORMED. NO PLEA OF IGNORANCE WILL BE ACCEPTED WILL BE ALLOWABLE REGARDING EXISTING CONDITIONS, EXTRA COMPENSATION WILL NOT BE ALLOWED FOR ANY WORK OR MATE- RIALS FOR WHICH THE CONTRACTOR SHOULD HAVE KNOWN PRIOR TO START. 18. CONTRACTOR IS REQUIRED TO VERIFY MEASUREMENTS AND DESIGN IN ACCORDANCE WITH ENGINEERED DRAWINGS PRIOR TO ORDERING MATERI- ALS. ANY DISCREPANCY BETWEEN ACTUAL SITE AND ENGINEERED DRAWINGS MUST BE MADE KNOWN TO THE DESIGN ENGINEER PRIOR TO WORK COMMENCEMENT, NO EXTRA COMPENSATION SHALL BE ALLOWED DUE TO THE DISCREPANCY BETWEEN DESIGN AND ACTUAL SITE. 19. CONTRACTOR SHALL MAKE AN EFFORT TO MATCH ALL MATERIALS WITH APPEARANCE TO BUILDING STRUCTURE IN A MANNER ACCEPTABLE WITH OWNER. IF PAINTING OF MATERIALS INSTALLED IS CONTRACTED, PAINT MUST NOT BE METALLIC. 20. IN THE EVENT OF DAMAGE TO AN EXISTING STRUCTURE, CONTRACTOR SHALL NOTIFY THE OWNERS AND MAKE REPLACEMENTS AND/OR REPAIRS TO THE DAMAGED AREA. ALL EXPENSES SHALL BE PAID BY THE GENERAL CONTRACTOR SELECTED FOR THE PROJECT. 21. CONTRACTOR SHALL NOTIFY OWNER OF CONSTRUCTION START DATE WELL IN ADVANCE OF ACTUAL COMMENCEMENT. 22. CONTRACTOR WILL MAINTAIN SITE CLEAN IN REGARDS TO ALL WORK PERFORMED BY THE CONSTRUCTION FOR THIS SYSTEM. DEBRIS WILL BE DIS- POSED OF OFF SITE IN ACCORDANCE WITH EPA STANDARDS. 23. CONTRACTOR SHALL INSTALL ALL REQUIRED MATERIALS FOR A SUCCESSFUL INSTALLATION OF THE REPEATER SYSTEM UNLESS OTHERWISE EX- CLUDED IN A WRITTEN CONTRACT OR IF IT IS PROVIDED BY OTHERS. 24. OWNER AND ENGINEER RESERVE THE RIGHT TO REJECT ANY EQUIPMENT OR MATERIALS WHICH IN THEIR OPINION ARE NOT IN COMPLIANCE WITH THE CONTRACT DOCUMENTS. 25. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXACT LOCATION OF UTILITIES AND FACILITIES PRIOR TO START OF CONSTRUCTION. 26. ALL SITE WORK IS TO BE COORDINATED BY THE CONTACTOR WITH LOCAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER UTILITY COMPANIES HAVING JURISDICTION OVER THIS LOCATION. 27. CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS BUILT DRAWINGS TO THE OWNER/CARRIER'S PROJECT ENGINEER. 28. ALL CONCRETE AND MASONRY PENETRATIONS SHALL BE DONE USING ROTARY ACTION ONLY. X-RAYS ARE TO BE TAKEN PRIOR TO DRILLING. 29. CONTRACTOR MUST RECEIVE APPROVAL PRIOR TO DRILLING OR CUTTING ANY WALLS, BEAMS OR JOISTS. 30. ALL PENETRATIONS MUST BE SEALED WATER TIGHT AND FIREPROOFED. 31. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE LAWS AND ORDINANCES OF ALL AHJ'S AND LATEST EDITIONS OF ALL CODES AND STANDARDS. THE MOST STRINGENT CODE WILL APPLY IN CASE OF DISCREPANCY. 31. CONTRACTOR SHALL SECURE ALL REQUIRED ELECTRICAL PERMITS AND PAY ASSOCIATED FEES. 32. RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANGE, SUBSTITUTIONS BETWEEN WORK AS SPECIFIED AND INSTALLED. 33. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE TURNED OVER TO CARRIER AT THE COMPLETION OF THE 34. GUARANTEE/WARRANTY: INSTALLATION TO BE FREE OF DEFECTS, SHORTS, GROUNDS, ETC., FOR A PERIOD OF ONE YEAR. 35. CONTRACTOR WILL COORDINATE WITH ALL OTHER TRADES AS REQUIRED. 36. CONTRACTOR WILL NOT INTERRUPT EXISTING SERVICES WITHOUT WRITTEN PERMISSION BY THE OWNER. 37. ANY DISCREPANCY IN THE DESIGN MUST BE MADE KNOWN TO THE ENGINEER IMMEDIATELY. 38. CONTRACTOR WILL PAY ALL ASSOCIATED FEES RELATED TO INSPECTIONS. 39. CONTRACTOR WILL -MAKE EVERY EFFORT TO SUCCESSFULLY PASS INSPECTIONS BY PROVIDING ALL REQUIRED DOCUMENTATION TO INSPECTOR AS REQUIRED. CONTRACTOR OR REPRESENTATIVE WILL BE ON -SITE DURING INSPECTION. 40. ALL INDOOR HANGARS, SUPPORTS, FASTENERS SHALL BE ZINC COATED OR OF EQUIVALENT CORROSION RESISTANCE BY TREATMENT. OUTDOOR USE SHALL BE HOT DIP GALVANIZED. 41. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL, SHALL ME OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) INDOORS AND NEMA 3R OR BETTER OUTDOORS, 42. PROVIDE APPROPRIATE WEATHER PROOFING MATERIALS FOR PENETRATIONS NEEDED TO BE SEALED FROM WATER INTRUSION. 43. DO NOT CUT MAJOR STRUCTURAL ELEMENTS WITHOUT APPROVAL. PATCHING SHALL BE OF QUALITY EQUAL TO AND OF MATCHING APPEARANCE OF EXISTING CONSTRUCTION. 44. ALL TIE WRAPS SHALL BE CUT FLUSH. 45. ALL ELECTRICAL SERVICE TO EQUIPMENT MUST BE GROUNDED AT THE SERVICE DISCONNECTING MEANS IN ACCORDANCE WITH LOCAL CODE. 46. PROVIDE EQUIPMENT WITH HIGHER FAULT CURRENT RATINGS AS NEEDED TO MATCH UTILITY COMPANY AVAILABLE FAULT CURRENT. 47. ALL CONDUIT BENDS SHALL BE MINIMUM OF 24 INCH RADIUS. 48. ALL METALLIC RACEWAYS SHALL BE GROUNDED PER NEC. 49. ALL CONDUIT USED MUST BE ELECTRICAL METALLIC TUBING (EMT) OR RIGID. 50. ALL CONDUIT MUST INCLUDE PULL STRINGS WITH A 200LB CAPACITY. 51. ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH ENGRAVED PLASTIC LABELS INCLUDING VOLTAGE RATING, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR CAPACITY RATING AND BRANCH CIRCUIT ID NUMBERS. 52. CONTRACTOR SHALL VERIFY THAT THE ENTIRE SYSTEM IS EFFECTIVELY GROUNDED, MEETS NEC ARTICLE 250 AND IS ACCEPTABLE BY THE AUTHORITY HAVING JURISDICTION. 53. ALL GROUND CONNECTIONS SHALL BE THOROUGHLY CLEANED AND MADE FREE OF FOREIGN MATERIAL TO ENSURE ADEQUATE BOND. 54. NO DEVIATIONS SHALL BE MADE TO ANY GROUNDING MATERIALS WITHOUT APPROVAL OF MANUFACTURER. 55. THIS ANTENNA SYSTEM IS DESIGNED TO COVER AREAS WHERE RADIO SIGNAL IS A MINIMUM OF-95dBm. ANY ARCHITECTURAL CHANGES TO THE BUILDING MAY AFFECT THE RF ENVIRONMENT THUS IMPACTING THE OVERALL COVERAGE OF THE SYSTEM WITH REGARDS TO COMPLIANCE. THE CON- TRACTOR OR PROJECT ENGINEER IS NOT LIABLE FOR ANY DESIGN MODIFICATIONS REQUIRED TO THE CHANGES DESCRIBED. 56. ANTENNAS MAY NEED TO BE REMOVED, RELOCATED OR ADDED UPON FINAL INSPECTION. 57. DAS INSTALLERS WILL NOT HAVE ANY OBLIGATION OR RESPONSIBILITY WHATSOEVER FOR OR ON ACCOUNT OF CONSEQUENTIAL OR INCIDENTAL DAMAGES SUSTAINED BY ANY PERSON, FIRM OR ORGANIZATION AS A RESULT OF MATERIALS, FABRICATION, ERECTION OR ANY INFORMATION OR CON-CLUSIONS CONTAINED IN THESE DRAWINGS, AND THE MAXIMUM LIABILITY OF DAS INSTALLERS, IF ANY, PURSUANT TO THESE DRAWINGS SHALL BE LIMITED TO THE TOTAL FUNDS ACTUALLY RECEIVED BY DAS INSTALLERS FOR THE PREPARATION OF THESE DRAWINGS. 58. PER NFPA-1221:9.6.3, 2016 EDITION -IF LIGHTING PROTECTION EXISTS FOR THE OCCUPANCY IT MUST MAINTAIN LIGHTNING PROTECTION FOR IT'S ENTIRETY. 59. ALL CODES SHALL COMPLY WITH THE FLORIDA ADMINISTRATIVE CODE 69A-48, NFPA-72, 2013 EDITION, NFPA-70, 2017 EDITION, NFPA-1221, 2016 EDITION, AND THE FLORIDA FIRE PREVENTION CODE, 6TH EDITION. 60. SYSTEM TO BE INSTALLED BY CONTRACTOR PER FLORIDA ADMINISTRATIVE CODE 61 G6-7.001(6) 61. GENERAL RADIO OPERATOR LICENSE HOLDER ON PROJECT: FCC #PG00061851 BDA SYSTEMS CO. PH: 9500 NW 12thS 1(855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO. felu JJ CONSULTING GROUP, IND. CA LICENlE #31838 JORGE J. 6ALOADO, P.E. 9#53400 Coal TIZEWELL CIRCLE # 1 saw ORLANDO, FL 38837 PROFESSIONAL SEAL: 3 SAt G `� ��,• NSF•;9Q NO. ; 1 1 2� ORS, . s/0NA �;,E I tl C#PG00061851 PROJECT INFORMATION: W � U-) E--- to V / M - L^ co Iw` v / 0 0 Q i- W �-- N a<i LL � 00 U_ Q _J CD MW V-- C'M ~ I..L REVISION: N k£rl Sp P I x RFj J F• h Y� � x �rt2� f.�rr L•'� -� y ._ i , i : 1 } r r s = n { 7y; r t 9'� } Y, r 1' S ' t 5 - g • `ram { t. •i s .� np y FYI' 4W. 5 ,I 7� .�. N 4 t� _ � ♦ � ti a �'{ 4 i" a'' t 1 c h U Y {� t z { t � �, y f 9? T� 9 1 i +f ,i t 8"x8"x4" JUNCTION BOX MOUNTED TO BACK OF CEILING TILE WITH HINGED COVER FACING UP. PROVIDE TILE BRIDGE / SUPPORT WIRE TO SUPPORT J-BOX FROM ABOVE. JUNCTION BOX SALL NOT BE SPORTED FROM CEILLING GRID SYSTEM SECURE ANTENNA TO JUNCTION BOX WITH PROVIDED PLASTIC NUT. CEILLING TILE SHALL BE SANDWICHED BETWEEN ANTENNA AND J-BOX. DRILL HOLE IN CEILING TILE COAX TYPE 'IN" CONNETOR COAX FROM PREVIOUS ANTENNA. MECHANICALLY PROTECTED. COMPRESSION CONNECTOR \--ACT CEILLING TILE NEW OMNI ANTENNA W/ THRU CEILING MOUNTING ACCESORIES ACT CEILING INSTALLATION - ANTENNA (END OF LINE) MNI ANTENNA MOUNTING DETAILS -ACT CEILLING NOTES: 1. ANTENNA AND MOUNTING HARDWARE TO BE INSTALLED IN ACCORDNACE WITH THE MANUFACTURERS SPECIFICATIONS. 2. PROVIDE NEMA 3R RATED J-BOX AND CONDUIT TO ACCESSIBLE CEILING SPACE WHEN ANTENNA IS INSTALLED ON BUILDING EXTERIOR. 3. SUPPORT ALL CONDUIT, EQUIPMENT, CABLES, AND JUNCTION BOXES IN ACCORDANCE WITH THE PROJECT SPECIFICATION, NEC CODE REQUIREMENTS, AND BICSI STANDARDS. 4. ALL SIZES AND DIMMESIONS GIVEN ARE MINIMUM REQUIREMENTS. IT IS THE CONTRACTORS RESPONSABILITY TO INCRESE SIZE AS REQUIRED TO FACILLITATE EQUIPMENT, MIN BEND RADIUS, CONNECTORS, ETC TO MEED CODES AND STANDARDS. /ROOF/DECK ABOVE / COAX TO NEXT ANTENNA. MECHANICALLY PROTECTED. ANTENNA INTERFACE BOX COAX JUMPER TO ANTENNA BOX TO BE MECHANICALLY PROTECTED. 8"x8"x4" JUNCTION BOX MOUNTED TO BACK OF CEILING TILE WITH HINGED COVER FACING UP. PROVIDE TILE BRIDGE / SUPPORT WIRE TO SUPPORT J-BOX FROM ABOVE. JUNCTION BOX SALL NOT BE SPORTED FROM CEILLING GRID SYSTEM SECURE ANTENNA TO JUNCTION BOX WITH PROVIDED PLASTIC NUT. CEILLING TILE SHALL BE SANDWICHED BETWEEN ANTENNA AND J-BOX. DRILL HOLE IN CEILING TILE NEW OMNI ANTENNA W/ THRU CEILING MOUNTING ACCESORIES COAX TYPE N CONNECTOR COAX FROM PREVIOUS ANTENNA. MECHANICALLY PROTECTED. COMPRESSION CONNECTOR NEW COAXIAL JUMPER NEW 16"X16"X4" OR GREATER JUNCTION BOX. MUST BE ACCESSIBLE. SHALL NOT SUPPORTED BY CEILING GRID. ANTENNA PIGTAIL COAX JUMPER FROM JUNCTION BOX ABOVE MECHANICALLY PROTECTED. ACT CEILLING TILE ACT CEILING INSTALLATION -ANTENNA / ROOF/DECK ABOVE / COAX TO NEXT ANTENNA. - MECHANICALLY PROTECTED. ANTENNA PIGTAIL. PROVIDE EXTENSION JUMPER IF REQUIRED TO REACH CONNECTOR. SECURE ANTENNA TO JUNCTION BOX WITH PROVIDED PLASTIC NUT NOTES: NEW SPLITTER / TAP NEW COAXIAL CABLE, TYP. AX TYPE N NNECTOR COAX FROM PREVIOUS ANTENNA. MECHANICALLY PROTECTED. COMPRESSION CONNECTOR NEW OMNI ANTENNA W/ THRU NEW 16"X16"X4" OR GREATER JUNCTION CEILING MOUNTING BOX. MUST BE ACCESSIBLE. MOUNTED ACCESORIES TO STRUCTURE. EXPOSED CEILING INSTALLATION -ANTENNA MNI ANTENNA MOUNTING DETAILS -EXPOSED CEILLING 1. ANTENNA AND MOUNTING HARDWARE TO BE INSTALLED IN ACCORDNACE WITH THE MANUFACTURERS SPECIFICATIONS. 2. PROVIDE NEMA 3R RATED J-BOX AND CONDUIT TO ACCESSIBLE CEILING SPACE WHEN ANTENNA IS INSTALLED ON BUILDING EXTERIOR. 3. SUPPORT ALL CONDUIT, EQUIPMENT, CABLES, AND JUNCTION BOXES IN ACCORDANCE WITH THE PROJECT SPECIFICATION, NEC CODE REQUIREMENTS, AND BICSI STANDARDS. 4. ALL SIZES AND DIMMESIONS GIVEN ARE MINIMUM REQUIREMENTS. IT IS THE CONTRACTORS RESPONSABILITY TO INCRESE SIZE AS REQUIRED TO FACILLITATE EQUIPMENT, MIN BEND RADIUS, CONNECTORS, ETC TO MEED CODES AND STANDARDS. / ROOF/DECK ABOVE / ANTENNA PIGTAIL. PROVIDE EXTENSION JUMPER IF REQUIRED TO REACH CONNECTOR. SECURE ANTENNA TO JUNCTION BOX WITH PROVIDED PLASTIC NUT NEW OMNI ANTENNA W/ THRU CEILING MOUNTING ACCESORIES COAX TYPE N CONNECTOR COAX FROM PREVIOUS ANTENNA. MECHANICALLY PROTECTED. COMPRESSION CONNECTOR NEW 8X8X4" OR GREATER JUNCTION BOX. MUST BE ACCESSIBLE. MOUNTED TO STRUCTURE. l 4 EXPOSED CEILING INSTALLATION -ANTENNA (END OF LINE' COAXIAL CABLE TO NEXT ANTENNAS TO BE MECHANICALLY PROTECTED THIRD OUTPUT V SPLITT NOTES: IYL..VV V%.4rr 1llL aJV1V11 LI\ V/""�ULL, 1 1 1 -W SPLITTER / TAP JAX FROM PREVIOUS VTENNA. MECHANICALLY 20TECTED. COMPRESSION CONNECTOR DAX TYPE N DNNETOR kTER JUNCTION BOX. MUST BE ACCESSIBLE. MOUNTED TO STRUCTURE. )-PASSIVE ONLY DEVICE MOUNTING DETAIL 1. EQUIPMENT TO BE INSTALLED IN ACCORDNACE WITH THE MANUFACTURERS SPECIFICATIONS. 2. SUPPORT ALL CONDUIT, EQUIPMENT, CABLES, AND JUNCTION BOXES IN ACCORDANCE WITH THE PROJECT SPECIFICATION, NEC CODE REQUIREMENTS, AND BICSI STANDARDS. 3. ALL SIZES AND DIMMESIONS GIVEN ARE MINIMUM REQUIREMENTS. IT IS THE CONTRACTORS RESPONSABILITY TO INCRESE SIZE AS REQUIRED TO FACILLITATE EQUIPMENT, MIN BEND RADIUS, CONNECTORS, ETC TO MEED CODES AND STANDARDS. BDA SYSTEMS CO. PH: 9500 NW 12thS (855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO. JJ CONSULTING GROUP, INC. CA LIOCN®S #31 d3® JOROE J. SALOACO, P.E.63800 2001 TIZEW6 LL CIRCLE #Isav ORLANDO, FL 32037 PROFESSIONAL SEAL: J. st No. 536 0 ; �.1i,9�1OR10P•'G����� N IAI 11E��\`N I T c #PG00061851 PROJECT INFORMATION: W ,L cy cn M U- ��^- V J u C 0 J_ 0 = N W CU) m U_ Q J m M n c0 ~ REVISION: DIRECTIONAL PUBLIC SAFETY DONOR ANTENNA. PANEL TYPE. TO BE POINTED DIRECTLY AT AHJ BROADCAST TOWER. 2" RIGID CONDUIT STUBBED UP 4' & GROUNDED L-BRACKET OR STRUCTURAL SYSTEM. FIELD VERIFY AND SUPPORT AS NEEDED. BOLT MAST TIED TO BUILDING STRUCTURE AT MINIMUM OF TWO POINTS ROOF ENTRANCE FRONT VIEW DETAIL DIRECTIONAL PUBLIC SAFETY DONOR ANTENNA. PANEL TYPE. TO BE POINTED DIRECTLY AT AHJ BROADCAST TOWER. 2" RIGID CONDUIT STUBBED UP 4' & GROUNDED UNITSTRUT STRAP ANTENNA MAST MUST BE GROUNDED BY COOPER WIRE MINIMUM AWG 6 WEATHERHEAD DONOR DETAIL CONNECTION TO BE WEATHERPROOF EXTERIOR ANTENNAS MUST BE 30' APART U-BOLT 2" EMT WEATHERHEAD ANTENNA MAST MUST BE GROUNDED BY COOPER WIRE MINIMUM AWG 6 CONNECTION TO BE WEATHERPROOF SIDE VIEW DETAIL BEAM CLAMP UNITSTRUT STRAP DIRECTIONAL PUBLIC SAFETY DONOR ANTENNA. PANEL TYPE. TO BE POINTED DIRECTLY AT AHJ BROADCAST TOWER. 2" RIGID CONDUIT STUBBED UP 4' & GROUNDED UNITSTRUT 1 •••• ;,,•••❑• WEATHERHEAD DONOR SIDE WALL DETAIL CONNECTION TO BE WEATHERPROOF UNITSTRUT STRAP J-POLE DETAIL I I ��� BDAMSYSTEMS CO. PH: 9500 NW 12thS 1(855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO. JJ GONSIULTING I3RMLIF, INO. DA Lla Kr4 R #31 d38 JORGE J. SALGADO, P.E. #53613:[] 0001 TIZKW..LL DIRGL@ # 7 6Qi ORLANDO, FL 3EM37 PROFESSIONAL SEAL: 34 G• �i ii T � ,'�tOR10P✓����� 'i S NAL C#PG00061851 PROJECT INFORMATION: r- W LL u �0 Q >- ui J u- > aQJ ��m U_ Q J m r-- c.0 REVISION: TA-78-1 SYSTEM DESIGN RISER N.T.S ROOF ANTENNA CABLE LM R600 COAXIAL PROTECTION INDOOR ANTENNA 00 HVAC COAXIAL CABLE MR-AP6012J50-RD BDA & UPS MUST BE WITHIN NEMA 4 RATED ENCLOUSER PSR-78-9533-X DEDICATED CKT110VAC-20A STANDARD GREEN INSULATED COPPER GROUND GROUND BASBAR BBU 0 0 0070 0 7O O O 0070 O 6 0 0 0 0 o O O O O O O O o 2 2HR FIRED RATED ROOM ENLARGEMENT N.T.S ALARMS (1) LOSS OF NORMAL AC POWER (2) BATTERY CHARGER FAILURE (3) SIGNAL BOOSTER FAILURE (4) DONOR ANTENNA MALFUNCTION (5) LOW BATTERY CAPACITY (TO 70% DEPLETION) ANNUNCIATOR. ALARM MODULES DEDICATED CKT11 OVAC-20A #6 AWG STANDARD ° I GREEN INSULATED COPPER GROUND STANDARD GREEN INSULATED COPPER GROUND TO BE INTO THE ALARM SYSTEM IL SYMBOL LEGEND SYMBOL I DESCRIPTION BDA SYSTEMS CO. PH; 9500 NW 12thS1 1(855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO. JJ 13ONSULTING GROUP, INC. DA LICE1482 #31 ®3H JORGE J. BALAADD, P.E. #53!}OO a D01 TIZZWKLL OIFLOLK 't1Sao ORLANDO, FL 3MB37 PROFESSIONAL SEAL: SAL 0Q�G��CENSF S: o. 3600 � r 13/ONAIL CABLE (DONOR) c #PG00061851 MR-AP6012J50-RD SPT 2 WAY (SPLITTER ) CABLE (SERVER) MR-AP6012J50-RD TA-78-1 (DIRECTIONAL DONOR) TA-0727-1 INDOOR OMINI (ANTENNA) -6dB (DIRECTIONAL COUPLER) PROJECT INFORMATION: - r— uj d- �--- M CO C � Q >- w uj f� EC LL > m U J 0_ < �I tD m v— c.0 Z) REVISION: PSR-78-9533—X # I DATE DESCRIPTION (PUBLIC SAFETY REPEATER) TSX-N F F SHEE TI TLE T EE== (COAXIAL SYSTEM DESIG PROTECTION ) PROJECT 2021-- SCALE: AS NOTED ISSUE 02/2112021 DATE: PUBLIC SAFETY D.A.S. (ERRC ) SHEET NUMBER: DAS-07 RISER(1) ON FIR; T TA-78-1 EMERGENCY RA 800MHz-SMF SITE PLAN LEVEL 1 NTS FIELD VERIFY BDA ROOM/LOCATION & DONOR ORIENTATION. �1 SYMBOL LEGEND SYMBOL 1 DESCRIPTION I CABLE (DONOR) MR-AP6012J50-RD SPT 2 WAY 2W (SPLITTER ) CABLE (SERVER) MR-AP6012J50-RD TA-78-1 (ANTENNA) TA-0727-1 INDOOR OMINI (ANTENNA) BDA BDA (BI-DIRECTIONAL AMPLIFIER) -6d B 6dB (DIRECTIONAL COUPLER) TSX-NFF (COAXIAL PROTECTION ) BDA SYSTEMS CO. PH: 9500 NW 12thS (855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO, J.1 CONSULTING OF -OUP, INC. DA LIGENNS #31 030 JOROE J. SALIZA©O, P.C. #53151313 80,01 TZKWKLL DIPOLE #16G• ORLANDO, M 381l37 PROFESSIONAL SEAL:�\\��11111111, 4 //���/ �� ��-��GENS •C''-9 yt N .53600 O ''ANAL E �\ FCc#PG00061851 PROJECT INFORMATION: T- wLo H W o 0 C Q >-- w J Q Lw < J cn m C) Q J m n REVISION: # I DATE I DESCRIPTION 1 SHEET TITLE: SITE PLAN L1 PROJECT 2021-- SCALE: AS NOTED ISSUE 02/21/2021 DATE': PUBLIC SAFETY D.A.S. (ERRCS) SHEET NUMBER: DAS-08 OSITE PLAN LEVEL 1-HEAT COVERAGE N Indoor prediction �egend Power [d Bra >-60.00 6.6%) SYSTEMS C 0. PH: 9500 NW 12thST 1(855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL - t'_3"=.a THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF (9_2%) BDA SYSTEM CO. JJ CONSULTING GROUP, INC. - DA LICENSE #311938 `_ +'� 'r 1 2-2 (100.09-� c JORGE J. 5ALOADO, P.E. #53500 21301 TIZEWELL CIRCLE #_ # 1 5091 ORLANDO, FL 32837 },,ply '-,{7 ��-y{ >-86.6 f ( 00-01%) PROFESSIONAL SEAL: -O 1 s 1 (10 0. O \\\\\\11III////// J. ��\\\O�G C E Nq` * ; No. 53 - _ 6 ( 0 0.0 %,) �, >100.00 (1010 ,�) NA /IIIIiII\\\\ Emergent Rad[O - 800 MHz - SMR - P25 SYMBOL LEGEND #PG00061851 [CC SYMBOL DESCRIPTION TA-0727-1 INDOOR PROJECT OMINI (ANTENNA) INFORMATION 75 = ui d- F-- u M M lL to u 0 J Qrfloo W J W QLLJ dam U U J Q I m c0 CEO REVISION: # DATE DESCRIPTION SHEET TI TLE: HEAT COVERAGE PROJECT 2021-- SCALE: AS NOTED ISSUE 02/21/2021 DATE: PUBLIC SAFETY D.A.S. (ERRCS) SHEET NUMBER: DAS_09 1 . ZOMIFUS17M71 Public Sarooett, Couplers MODEL: TA-XDB-N High quality directional couplers for use on public safety BDA systems. FREQUENCY RANGE (MHZ) COUPLING (dB) INSERTION LOSS (dB) 700-2700 MHz 6.0 / 10 /15 /20 / 30 dBi 1.7 / 0.810.5 / 0.3 / 0.2 DIMENSIONS 6.15" x 2.6" x 0.88" VSWR <1.32 COUPLING FLATNESS +/- 0.6 dB DIRECTIVITY 20-24 d6 CONNECTOR N-Female MAX POWER 50W IMPEDENCE ENVIRONMENT 500 INDOOR HUMIDITY Up t0100% 6dB MODEL TA-6DB-N-U 10dB MODEL 15dB MODEL TA-10DB-N-U TA-15DB-N-U 20d6 MODEL 30dB MODEL TA-20DB-N-U TA-30DB-N-U Technical Antennas 9500 NON 12 ST #5 Dora(, FL 33172 1 Tel. 305- 30-399 Designed and engineered in Miami, Florida USA,. For more information, please visit www.technicalantennas.corn YTIMESMICROWAVE SYSTEMS Calculate Attenuation = (0.075550) • -� -FMHz + (0.000260) • FMHz (interactive calculator available at http://www.timesmicrowave.com/cable_calculators) Attenuation: VSWR=1.0; Ambient = +25°C (77°F) Power: VSWR=1.0; Ambient = +40°C; Inner Conductor = 100°C (212°F); Sea Level; dry air; atmospheric pressure; no solar loading (800) TMS-COAX • www.timesmicrowave.com 33 WIOEBANO Power Dividers MODEL: TA-PD-X High quality power dividers (splitters) for use on public safety BDA systems. FREQUENCY RANGE (MHZ) 700-2700 MHz GAIN LOSS (0) -3.0 / -4.3 / -6.6 dBi VSWR < 1.3 CONNECTOR N-Female MAX POWER IMPEDENCE 50W 500 ENVIRONMENT Indoor HUMIDITY Up to 100% 2 WAY MODEL TA-PD-2 DIMENSIONS 3.7" x 3.6" x .8" 3 WAY MODEL TA-PD-3 DIMENSIONS 4.5" x 3.5" x 1.0" 4 WAY MODEL TA-PD-4 DIMENSIONS 4.5 x 4.5" x 1.0" MATERIALS FINISH Cast Aluminum Housing Electrostatic Powder Coating Technical Antennas 9500 NW 12 ST #5 Doral, FL 33172 1 Tel. 305-6 0-3995 Designed and engineered in Miami, Florida USA. For more information, please visit www,technicalantennas.coin 7rT1MESM,CR0.1VAVE SYSTEMS LMRO-600 Flexible Low Loss Communications Coax 1 2 k 3 5 + _ w� ,E. TC-6D0=-,,. EZ 600- t; ; 78EIA TC-600.7fi FEZ 600-716M-X TC-600-716M-X 716M€ 3180 $' 4= 3190-1373 u.;. 3190. 3190-2643' 3190-2642 _ 6 7 8 9� 10 TC-600-716M-RA-D 3190.2599 EZ-600-716M-RA X - EZ 600 716E TC-600-HNMG TC-600-LCM 3190-2546 3190-2447 ' 1 - 4 3190.1406 11 12 13 h 14 15 w w .o EZ-600-NF-X -Np TC-600-NF-BH' �,e'VT -6 TC-600-NF-X 3190-2817 EZ-600-NF•BH 3190-588 C 00 C BH 3190-2816 3190-616 3190-466 16 17 1g 19 20 EZ-600-NMH-RA•X' U3190-2639 ! ryEZ-600-N EZ 600-NMC-2-D EZ-600-NMH-X #� 600-NMH-X - 3190-6¢ �� 3190-2641 3190-2627 - 3190 2628 21 . TC-600-NMH-RA-D 22 23 ETC-600-BM-RA 24/25 26 3190-2427 as 3190-2734 0 - 'X a .. 3190-2530 " ll C-600-NMH-75-50 EZ-600-TM-X - - EZ-600-TM-RP 3190.1610 fir;, 3180-2531 3190-796 1. 718 EIA Flange EZ-600-78EIA 3190-1373 <1.25:1 (2.5) NA Spring Finger Clamp S/S 2.3 (58) 2.60 (66.0) 0.873 (396.0) 2. 7-16 DIN Female Straight Jack TC-600-716FC 3190-375 <1.25:1 (2.5) NA Solder Clamp S/S 1.1 (28) 1.00 (25.4) 0,249 (112.9) 3. 7-16 DIN Straight Plug EZ-600-716M-X 3190-2643 <1.30:1 (6) Hex Spring Finger Crimp A/S 1.6 (42) 1.38 (35.0) 0.209 (94.80 4. 7-16 DIN Straight Plug TC-600-716M-X 3190-2642 <1.30:1 (6) Hex Solder Crimp A/S 1.6 (40) 1.38 (35.0) 0.191 (86.6 5. 7-16 DIN Straight Plug TC-600-716MC 3190-502 <1.25:1 (2.5) Hex Solder Clamp S/S 2.0 (51) 1.30 (33.0) 0.347 (157.4) 6. 7/16 Male Right Angle EZ-600-716M-RA-X 3190-2546 <1.35:1 (6) Hex Spring Finger Crimp A/G 1.6 (40) 1.38 (35.0) 0.462 (210.0) 7. 7-16 DIN Right Angle TC-600-716M-RA-D 3190-2599 <1.35:1 (6) Hex Solder Crimp A/S 1.7 (44) 2.00 (50.9) 0.362 (164.2) 8. 7-16 DIN Straight Jack EZ-600-716F 3190-2447 <1.25:1 (6) Hex Spring Finger Crimp A/G 1.8 (45) 1.32 (33.6) 0.158 (71.7) 9. HN Male Straight Plug TC-600-HNMC 3190-1429 <1.25:1 (<1) Knurl Solder Clamp S/g 2.3 (59.2) 0.88 (22.4) 0.25 (113) 10. LC Male Straight Plug TC-600-LCM 3190-1406 <1.25:1 (<1) Hex Solder Clamp NIS 3.1 (78.0) 1.62 (41.1) 1.20 (544) 11, N Female Straight Jack TC-600-NF-X 3190-2816 <1.30:1 (6) NA Solder Crimp A/G 1.7 (43) 0.69 (17.6) 0.076 (34.6) 12. N Female Straight Jack ` EZ-600-NF-X 3190-2817 <1.30:1 (6) NA Spring Finger Crimp A/G 17 (43) 0.69 (17.6) 0.090 (40.6) 13. N Female Bulkhead Jack EZ-600-NF-BH 3190-616 <1.25:1 (2.5) NA Spring Finger Crimp SIG 2.4 (61) 0.88 (22A) 0.195 (88.5) 14. N Female Bulkhead Jack TC-600-NF-BH 3190-589 <1.25:1 (2.5) NA Solder Crimp SIG 2.4 (61) 0.88 (22.4) 0.195 (88.5) 15, N Female Bulkhead Jack TC-600-NFC-BH 3190-466 <1.25:1 (2.5) NA Solder Clamp SIG 2.2 (56) 0.94 (23.9) 0,214 (97.1) 16. N Male Straight Plug EZ-600-NMK 3190-669 <1.25:1 (2.5) Knurl Spring Finger Crimp SIG 2.1 (53) 0.92 (23.4) 0.164 (74.4) 17. N Male Straight Plug EZ-600-NMC-2-D 3190-2641 <1.25:1 (6) Hex/Knurl Spring Finger Clamp A/G 2.1 (53) 0.92 (23.4) 0.202 (91.6) 18. N Male Straight Plug EZ-600-NMH-X 3190-2627 <1.25:1 (8) Hex/Knurl Spring Finger Crimp A/G 2.1 (53) 0.92 (23.4) 0.164 (74.4) 19, N Male Straight Plug TC-600-NMH-X 3190-2628 <1.25:1 (8) Hex/Knurl Solder Crimp A/G 2.1 (53) 0.92 (23.4) 0.166 (75.3) 20. N Male Right Angle EZ-600-NMH-RA-X 3190-2639 <1.35:1 (6) Hex Spring Finger Crimp A/G 2.0 (50) 1.42 (36.0) 0.224 (101.7) 21. N Male Right Angle TC-600-NMH-RA-D 3190-2427 <1.35:1 (6) Hex Solder Crimp A/G 1.8 (46.5) 1.62 (41.2) 0.185 (84.3) 22. N Male Straight Plug TC-600-NMH-75-50 3190-1610 <1.35:1 (6) Hex Solder Crimp N/G 2.1 (52.8) 0.91 (23.1) 0.130 (59.0) 23, BNC Male Right Angle TC-600-BM-RA 3190-2734 1.30:1 (4) Knurl Solder Crimp A/G 1.8 (45.5) 1.54 (39.0) 0.164 (74.3) 24. TNC Male Straight Plug TC-600-TM-X 3190-2530 <1.25:1 (6) Hex/Knurl Solder Crimp A/G 2.3 (57.6) 0.75 (19.0) 0,100 (45.6) 25. TNC Male Straight Plug EZ-600-TM-X 3190-2531 <1.25:1 (6) Hex/Knurl Spring Finger Crimp A/G 2.3 (5T6 0.75 (19.0) 0.100 (45.6) 26. TNC Male Reverse Polarity EZ-600-TM-RP 3190-796 <1.25:1 (2.5) Knurl Spring Finger Crimp A/G 2.2 (56) 0.87 (22.0) 0.112 (50.8) 27. TNC Male Reverse Polarity TC-600-TM-RP 3190-1064 <1.25:1 (6) Knurl Solder Crimp N/G 2.1 (53.3) 0.68 (17.3) 0.112 (50.8) 28. TNC Male Right Angle TC-600-TM-RA-D 3190-2707 <1.35:1 (6) Hex/Knurl Solder Crimp A/G 1.6 (41) 1.75 (44.5) 0.164 (74.3) 29. TNC Female Reverse Polarity EZ-600-TF-RP 3190-797 <1.25:1 (2.5) NA Spring Finger Crimp A/G 2.3 (58) 0.87 (22.0) 0.100 (45.4) 30. TNC Female Reverse Polarity TC-600-TF-RP 3190-1065 0.35:1 (6) Knurl Solder Crimp N/G 2.2 (55.8) 0.68 (17.3) 0.100 (45A) 31. UHF Male Straight Plug EZ-600-UM 3190-615 0.25:1 (2.5) Knurl Spring Finger Crimp SIG 1.7 (43) 0.88 (22.4) 0.164 (74.4) 32. UHF Male Straight Plug TC-600-UMC 3190-213 <1.25:1 (2.5) Knurl Solder Clamp SIG 1.7 (43) 0.88 (22A) 0.198 (89.8) Finsh metals: N=Nickel, S=Silver, G=Gold, SS=Stainless Steel, A=Alballoy "'VSWR spec based on 3 foot cable with a connector pair 'Available in bulk pack 34 (800) TMS-COAX • www.timesmicrowave.com 7NMESMICRO.VAVE SYSTEMS LMIR®-600 Flexible Low Loss Communications Coax Ideal for... • Jumper Assemblies in Wireless Communications Systems • Short Antenna Feeder runs • Any application (e.g. WLL, GPS, LMR, WLAN, WISP, WiMax, SCADA, Mobile Antennas) requiring an easily routed, lovv loss RF cable LMR-600-DB Outdoor/Watertight PE Black 540931 LMR-600-FR Indoor/Outdoor Riser CMR FRPE Black 54032 LMR-600-FR-PVC Indoor/Outdoor Riser CMR FRPVC Black 54074 LMR-600-PVC General Purpose PVC Black 54219 LMR-600-PVC-W General Purpose PVC White 54206 Bend Radius: installation in. (mm) 1.50 (38.1) Bend Radius: repeated in. (mm) 6.0 (152.4) Bending Moment ft-lb (N-m) 2.75 (3.73) Weight Iblft (kg/m) 0.131 (0.20) Tensile Strength lb (kg) 350 (158.9) Flat Plate Crush lb/in. (kg/mm) 60 (1,07) Inner Conductor Solid BCCAI 0.176 (4,47) I Dielectric Foam PE 0.455 (11.56) Outer Conductor Aluminum Tape 0.461 (11.71) Overall Braid Tinned Copper 0.490 (12.45) Jacket _ _ (see table) _ 0.590 (14.99) Environmental Specifications Performance Property Installation Temperature Range 'IF -40/+185 *C -40/+85 Storage Temperature Range -94/+185 -70/+85 Operating Temperature Range -40/+185 -40/+85 Velocity of Propagation % 85 Dielectric Constant NA 1.32 Time Delay nS/ft (nS/m) 1.17 (3.83) Impedance ohms 50 Capacitance pF/ft (pF/m) 23.4 (76.6) Inductance uH/ft (uH/m) 0.058 (0,19) Shielding Effectiveness dB >90 DC Resistance Inner Conductor ohms/1000ft (/km) 0.53 (1.7) Outer Conductor ohms/1000ft (/km) 1.2 (3.9) Voltage Withstand Volts DC 4000 Jacket Spark Volts RMS 8000 Peak Power kW 40 32 (800) TMS-COAX • www.timesmicrowave.com 7rTIMESM,CROWAVE SYSTEMS 10 rt CT-U TC-600-UMC 3192.1814010 3190-213 GST-600A CCT-02 CT-600 3190-1051 3192-165 3192-170 CST-600 - 3192452 CR-600 RS-456 3190-831 3190-42 t� s ' K-600EZ . 4 172 . WR-600 L U � •... Y 3190.1435 3192-001 - ,0112.086 3 3190-1602 Part Stock Type Number Code Description Install Tools Crimp Tool CT-U 3192-181 Crimp Handle Crimp Dies Y1720 3190-203 .610" Hex Dies Crimp Rings CR-600 3190-831 Crimp Rings for TC/EZ-600 connectors (pkg of 10) Strip Tool CST-600 3192-052 Combination prep tool for LMR-600 crimp and clamp style connectors Crimp Tool CT-600 3192-170 Crimp tool for LMR 600 connectors Replacement Blades RB-456 3190-421 Replacement Blades for Strip Tools Deburr Tool DBT-U 3192-001 Removes center conductor rough edges Midspan Strip Tool GST-600A 3190-1051 For ground strap attachment Wrench WR-600 3190-1435 15/16" Box Wrench (2 required for EZ-600-NMC-2) Cutting Tool CCT-02 3192-165 Cable end flush cut tool Replacement Blade RB-02 3192-166 Replacement blade for cutting tool Replacement Blade Kit RB-CST 3192-086 Replacement blade kit for all CST strip tools Tool Kit TK-600EZ 3190-1602 Tool kit for LMR crimp/clamp connectors (includes CCT-02, CST-600, CT-600, Tool Pouch) CS-A600T,.r # SH-1.11600T HG-600T CS-60120T, CS-6017-OT OK-S600TT �1 CB-600T lip W1 Pon B-600-NM IPB-600-NF 3109.417-4 3109417 5 x 1 WS13-600 Hanger Support Hardware A 3108-40t SC 600T Part Stock _Type Number Code Description Hardware Accessories Ground Kit GK-S600TT GK-S600TT Standard Grounding Kit (each) Hoisting Grip HG-600T HG-600T Split/Laced Type (each) Cold Shrink CS-A600T CS-A600T Cable to Antenna Junction (each) Cold Shrink CS-60120T CS-60120T LMR-600 to -1200 Junction (each) Cold Shrink CS-60170T CS-60170T LMR-600 to -1700 Junction (each) Hanger Blocks CB-600T CB-600T Dual Cable Support Block (kit of 10) Stand. Entry Port Cushion SC-60OT-3 Three cables (each) Snap -In Hangers SH-1.1600T SH-L1600T Snap -In Hangers (Kit of 10) Hanger Block Supporting Hardware Complete Range of Supporting Hardware & Adapters Available Weather Proof BootIPB-600-NM 3109-600-NM LMR-600 Male IP boot suitable for type N, TNC, BNC, 4310, 4195 Weather Proof BootIPB-600-NF 3109-600-NF LMR-600 Female IP boot suitable for type N, TNC, BNC, 4310, 4195 Weather seal boots WSB-600 3109-401 Weather seal strain relief boot (10 pk) for use with most popular LMR-600-: series connectors (800) TMS-COAX www.timesmicrowave.com 35 BDA SYSTEMS CO. PH: 9500 NW 12thST 1(855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO. .- JJ CONSLILTIN. GROUP, INC. ., CA LICENOE #31 838 g' 1 1 JORGE J. SALDADD, P.E. #53500 2DDI TI2EWELL CIRCLE ❑BLAND 1, FL 321337 PROFESSIONAL SEAL: \\\ C \�\\ �CENSF� �.0 - 1 p S 8'T14T OF tf \� o?SS�ONA 11�?\��\ 11111 KC#P000061851 PROJECT C INFORMATION: G V-- w LO E- CY) M LL '� �/ V J U 0 J C < Q>-LU J LW > a<-M.1 v / W U W � C� ^ CD REVISION: 0 BUSBAR ASSEMBLIES WITH LUG KITS Busbar Assemblies With Lug Kits contain the CPI 13622 series Telecommunications Grounding Busbar (TGB) or the CPI 40153 series Telecommunications Main Grounding Busbar (TMGB) along with required stainless steel hardware to fasten the two -hole ground lugs to the Busbar. ■ #6 lugs are 2-hole lugs with 1/4" hardware ■ #2, 2/0 and 4/0 lugs are 2-hole lugs with 3/8" hardware u� LISTED 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 =- 0 0 O O 0 O 0 =- o 0 0 0 , I 0 0 0 0` _-'0 0 0 0 0 0 , 0` --'0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 URNLJ00 000000000000 0 0 N. 0 0 0 ®0 0 0 0 0 0 0 0 0 0 0 O O O O ® o o • 0 000000 0 40158-020 Shown des rlt � 'aft% - 4156-612 TGB Pgttern 2"UU:x 1/4-ii 12"L' 6 ei" `ea) 1 ea= 0 5 lb 40158-012 TMGB Pattern 4"W x 1/4"H x12"L 6 ea 3 ea 1 ea 1 ea 8 lb 40158-020 TMGB Pattern 4"W x 1/4"H x 20"L 6 ea 3 ea 1 ea 1 ea 11 Ib AD Product Specification THE SIGNAL FOR SUCCESS ADRF-BBx Series (12V / 24V / 48V Battery Backup for Public Safety Applications) • NFPA 2016 compliant including 12 hour runtime, battery disconnect alarm, and NEMA 4 compliant enclosure • Increase runtime by adding unit using parallel cable • Available in 12V, 24V, 48V • Includes single cable between battery and DAS / repeater Electrical Specification ADRF-BBS-12 ADRF-BBL-12 ADRF-BBS-24 ADRF-BBL-24 ADRF-BBL-24 x 2 ADRF-BBL-48 Operating Voltage 12V 12V 24V 24V 48V 48V Battery Capacity 100Ah 240Ah 50Ah 120Ah 120Ah 500 Configuration Parallel: Parallel Series, Series Series Series Battery Type Lead Acid Lead Acid Lead Acid Lead Acid Lead Acid Lithium Ion Mechanical Specification ADRF-BBS-12 ADRF-BBL-12 ADRF-BBS-24 ADRF-BBL-24 ADRF-BBL-24 x 2 ADRF-BBL-48 15.0 1 . x9.3din.' Dimension x 14 1S.6x16. xl in. 7 0.8 15Ax11.4x9.3 in; 4 15. klfi.7x10.8in. 6 15:6 x 16.Tx 10. 8 I n. 1S6x16.7x 10 (zz) .bin. Weight 82.5 lbs. 195 lbs. 82.5 lbs. 195 lbs. 195 lbs. (x2) 120 lbs. Weather Resistance NEMA 4 NEMA 4 NEMA 4 NEMA 4 NEMA 4 NEMA 4 Cooling Air Convection Air Convection Air Convection Air Convection Air Convection Air Convection Ground (with wheel Ground (with wheel Ground (with wheel Ground (with wheel Ground (with wheel Ground (with wheel Mounting Type locks) or Wall . locks) or Wall locks) (includes bratkets) lacks) (includes brackets) tucks) locks)- Battery Runtime ADRF-885-12 ADRF-BBL-12 ADRF-BBS-24 ADRF-BBL-24 ADRF-BBL-24 x 2 ADRF-BBL-48 PSR-VU-9537 30.72 hours 12.8 hours 4 PSR-78-9533 � - - 11.8/9.4hours 28.8/22.8hours ' (single /dual band) ' PSR C (dual band @ 1W) -78-9533 10.1 hours 2432 hours PSR78-9030 - -- 6.4 hours 15.5 hours ADXV PS HE (for 4 RU) 26.6 hours 63.8 hours v ADXV PS HE (for 8 RU) 18.1 hours 43.5 hours ADXV-R-3378P-N4X 25.4'hours 61.2 hours - k ADXV-R-25VU-N4X 23.2 hours 55.8 hours Specifications are subject to change without notice. ©2017 Advanced RF Technologies, Inc. :11 : `6' .1. www.chatsworth.com ©2003 Chatsworth Products, Inc. All rights reserved. CPI is a registered trademark of A - THE SIGNAL FOR SUCCESS TEL +1 818. 840. 8 13 1 1 FAX +1 818. 840. 8 13 8 CHATSWORTH PRODUCTS, INC. Chatsworth Products,Inc. All other trademarks belong to their respective companies.06/03 TECHNICAL/CUSTOMER SUPPORT+1 800. 313. 9345 page 1 of 1 www.adrftech.com 1 3116 West Vanowen Street, Burbank, CA 91 505 USA TRILOGY' A IN r C Connectors & Tools Communications 7.1111e"I" AM NMP01250 AirCell@ 50 Ohm Connectors For use with AirCell@ 1/2" 50 Ohm Plenum, Conduit and In -Conduit Cables 6 -111,141#11" 1 i General Specifications Interface IN Male Body Style IStraight Electrical Specifications Impedance, Ohms 50 Operating Frequency Band 0.3 MHz to 6 GHz Dielectric Withstand Voltage 2 kV DC 3rd Order IMD -140 dBc minimum, -150 typical 3rd Order IMD, Test Method 2 x 20 Watt carriers Average Power 0.6 kW Peak Power, maximum 10 kW Insertion Loss, typical 0.05 Shielding Effectiveness -130 dB Return Loss (VSWR) DC to 1 GHz 30 dB (1.06) 1 GHz to 2 GHz 31 dB (1.06) 2 GHz to 3 GHz 32 dB (1.06) 3 GHz to 4 GHz 25 dB (1.12) 4 GHz to 5 GHz 20 dB (1.22) 5 GHz to 6 GHz 15 d6 (1.43) Mechanical Specifications Outer Contact Plating Silver Inner Contact Plating Silver Interface Durability 500 cycles Interface Durability Test Method IEC 16916 Minimum Connector Pull -off Force 200 lbs Environmental Specifications Operating Temperature, °F (°C) -40' to 158' (40' to 70') Storage Temperature, 'F (°C) -40° to 158° (40° to 7W) Installation Temperature, °F (°C) 23' to 122' (-5° to 50°) Immersion Test Method IEC60529:2001 IP68 Corrosion Test Method MIL-STD-1344A Thermal Shock Test Method MIL-STD-202F Vibration Test Method MIL-STD-202F Regulatory Compliance/Certifications RoHS 2011/65/EU Compliant TL 9000 H-V - All Cables designed and manufactured under this quality management system 2016 Triloav Communications. Inc. All rights reserved. All trademarks identified by @ are registered trademarks o Trilogy Communications. All Specifications are subject to change without notice. See www.trilogycoax.com or call 800-TRILOGY for the most current information. Revised 09/15/16 Notice: Trilogy disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance or removal practices ADVANCED RF TECHNOLOGIES, INC. Tel +1 818.840.8131 Fax +1 818.840,8138 THE SIGNAL FOR SUCCESST" Technical/Customer Support +1 800.313.9345 3116 West Vanowen Street Burbank, CA 91505 Web www.adrftech.corn PSR-78-9533-X w/ ADRF-BBL-X-24 Battery Runtime Calculations PSR-78-9533-X (Single Band) w/ PSR-78-9533-X (Single Band) w/ (1) ADRF-BBL-X-24 (2) ADRF-BBL-X-24 + ADRF-BBX-CBL-21P Repeater Repeater • DC Power Consumption (W)-100.69 • DC Power Consumption (W)-100.69 • DC Voltage (V) - 24.02 • DC Voltage (V) - 24.02 • DC Current Draw (A) - 4.192 • DC Current Draw (A) - 4.192 (1) Battery Backup (2) Battery Backup w/ Parallel Cable • Battery Capacity (Ah) - 120 • Battery Capacity (Ah) - 240 Calculations Calculations • Runtime (h) = Battery Capacity (Ah) / Current Draw (A) • Runtime (h) = Battery Capacity (Ah) / Current Draw (A) • Runtime (h) = 120Ah / 4.192A • Runtime (h) = 240Ah / 4.192A • Runtime (h) = 28.63h • Runtime (h) = 57.25h PSR-78-9533-X (Dual Band) w/ PSR-78-9533-X (Dual Band) w/ (1) ADRF-BBL-X-24 (2) ADRF-BBL-X-24 + ADRF-BBX-CBL-21P Repeater Repeater • DC Power Consumption (W)-127.16 • DC Power Consumption (W)-127.16 • DC Voltage (V) - 24.02 • DC Voltage (V) - 24.02 • DC Current Draw (A) - 5.294 • DC Current Draw (A) - 5.294 (1) Battery Backup (2) Battery Backup w/ Parallel Cable • Battery Capacity (Ah) -120 • Battery Capacity (Ah) - 240 Calculations Calculations • Runtime (h) = Battery Capacity (Ah) / Current Draw (A) • Runtime (h) = Battery Capacity (Ah) / Current Draw (A) • Runtime (h) = 120Ah / 5.294A • Runtime (h) = 240Ah / 5.294A • Runtime (h) = 22.67h • Runtime (h) = 45.33h TRILOGY Plenum Cable Communications A'1rCe11®R 50 Ohm 1/2" Plenum Cable Inside Metal Raceway - MR-AP6012J50-RD i- a o a♦ e Plenum Rated Cable Inside Metal Raceway Metal Raceway, 1/2", Red, Corrugated (6 GHz), Jacketed GIMP, Conforms to NFPA-262, UL-444, Canadian CSA 22.2/FT6 MR-AP6012J50-RD Physical Dimensions Center Diameter, in (mm) 0.188 (4.78) Diameter Over Outer Conductor, in (mm) 0.550 (13.97) Maximum Diameter Over Jacket, in (Area (in2))0.62 (0,3019) Inside Diameter of Metal Raceway, in (Area (in2))0.852 (0.5701) Maximum Diameter Over Metal Raceway, in (mm) 1.08 (27.43) Fill Rate of Metal Raceway 52.95% Center Conductor Copper -Clad Aluminum Outer Conductor Corrugated Aluminum Jacket Color Red Metal Raceway Interlocked Aluminum Electrical Characteristics Maximum Frequency, GHz 10 Peak Power Rating, KW 35 DC Resistance, Ohms/1,000 ft (1,000 m) Center 0.46 (1.51) Outer 0.51 1.67 DC Breakdown, kV 2 Capacitance, pF/ft (m) 22 (72A2) Inductance, mH/ft (m) 0.057 (0.187) Jacket Spark, kV RMS 8 VSWR min, (dB) 1.25 (19.0) VSWR typical, 150 / 450 / 698-960 / 1700-2200 MHz (dB) 1.13 (24.3) Impedance, Ohms 50 ± 2 Velocity of Propagation 94% Mechanical Characteristics Minimum Bend Radius, in (mm) 7 (178) Cable Weight, lb/ft (kg/m) 0.26 (0.39) Bending Moment, ft lb (N m) 15 (20.3) Tensile Strength of Metal Raceway, lb (kg) 150 (68) Clamp Spacing, ft (m) 15(1.52) Metal Raceway utilizes standard MC/AC %" connectors and hangers Recommended Install Temp., 'F ('C) +5' to 194' ( 15' to 90°) Recommended Storage Temp., °F (°C) +5' to 194' (-15' to 90°) Recommended Operating Temp., 'F ('C) +5' to 194' ( 15' to 90') Standard Conditions For Attenuation: VSWR 1.0, Ambient Temperature 20oC (68°F) For Average Power: VSWR 1.0, Ambient Temperature 40°C (104°F), Inner Conductor Temperature 100°C (212°F), No Solar Loading Regulatory Compliance/Certifications RoHS 2011/65/EU Compliant TL 9000 H-V - All Cables designed and manufactured under this quality management system NFPA 72 (2019), Section 12.4.2 - Pathway Survivability Level 1 shall consist of pathways 0 buildings that are fully protected by an automatic sprinkler system in accordance with NFPA 13 with any interconnecting conductors, cables, or other physical pathways installed in metal raceways. ©2016 Trilogy Communications, Inc. All rights reserved. All trademarks identified by V are registered trademarks of Trilogy Communications. All Specifications are subject to change without notice. See www.trilogyrf.com or call 800- TRILOGY for the most current information. Revised 04/13/20 PSR=ANN Frequency, Attenuation MHz dB/100 ft dB/100 m Average Power kW 100 0.70 2.30 3.98 450 1.50 4.92 1.85 500 1.59 5.22 1.75 600 1.75 5.74 1.58 700 1.87 1 6.14 1.47 800 1.96 6.43 1.37 900 2.14 7.02 1.29 960 2.23 7.32 1.24 1000 2,30 7.55 1.21 1500 2.85 9.35 0.98 1700 3.05 10.01 0.98 1800 3.14 10.30 0.93 1950 3.24 10.63 0.85 2000 3.33 10.93 0.84 2100 3.42 11.22 0.82 2200 3.50 11.48 0.80 2300 3.59 11.78 0.78 2400 3.67 12.04 0.77 2500 3.75 12.30 0.75 2700 3.90 12.80 0.72 3000 4.14 13.58 0.68 3300 4.33 14.21 0.61 3400 4.45 14.60 0.60 4000 4.91 16.11 0.55 4900 5.61 18.41 0.50 5000 5.69 18.67 0.49 5200 5.92 19.42 0.48 5300 6.03 19.78 0.47 5600 6.37 1 20.90 0.46 5825 1 6.83 1 22.41 0.45 Trilogy AirCell° Cable Proud to be 100% Made in the USA Annunciator for Public Safety Repeaters 10 Tested and approved under UL 2524, Second Edition by MET Laboratories, Inc. • NFPA 72 2016 code compliant 6i Visual and Audible alarms for Normal AC Power, Loss of Normal AC Power, Battery Charger Failure, Low Battery Capacity, Donor Antenna Malfunction, Active RF Emitting Device Malfunction, System Component Malfunction, and Donor Antenna Disconnection Q Decibel Level of 100 dB @ lm 0 1 P66 Rated Specifications Parameters Specifications Dimensions (W x D x H) 5.91 x 2.84 x 6.32 in. (w/o bracket) Weight 2.5 lbs. (w/o bracket) Weather Resistances IP66 Decibel Level 100dB @ lm Alarm Soecifications AAI Alarm Name Detail Alarm Visual Audible Normal AC Power ` AC ON Green LED (Normal) '; Off (Normal) Loss of Normal AC Power AC Fail Red LED (Alarm) On (Alarm) AC Fail Battery Not Charged Battery Fail Battery Charger Failure Battery Not Connected Red LED (Alarm) On (Alarm) Low' Battery Battery Not Connected Battery Fail Low Battery Capacity Low Battery Battery Not Connected Red LED (Alarm) On (Alarm) (70% Depletion) Donor Antenna Malfunction Donor Antenna Malfunction Red LED (Alarm) Red LED (Alarm) On (Alarm) ` DL RF Power Soft Fail DL/UL Out of Band Overload Soft Fail Active RF Emitting Device Malfunction DL/UL Input Overload Soft Fail Red LED (Alarm) On (Alarm) DL VSWR Hard Fail DL Oscillation Hard Fail Over Temperature Hard Fail System Halt System Component Malfunction Red LED (Alarm) On (Alarm) DL/UL Out of Band Overload Hard Fail DSP Fail Donor Antenna Disconnection Donor Antenna Disconnection Red LED (Alarm) On (Alarm) BDA SYSTEMS CO. PH: 9500 NW 12thST 1(855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO. c Jai CONSULTING GROUP, INC. CIA LIOENiE #31 838 r'. JORGE J. SALGADO, P.E. #53600 8OD1 TILEWELL CIRCLE an 3 #1SOD ONLANDO, FL 38837 PROFESSIONAL SEAL: w11 I I II ////,� J. -SA4CEN 3600 ; l000. �( , �S�ONA 11E?���\ C#PG00061851 PROJECT INFORMATION: CC G w LO LO M lU_ 10 W U 0 0 J_ QCK Z Q >_ LJ J > aQ_J LW W m U J Q _ _I 0 m C0 I..L. REVISION: # I DATE DESCRIPTION SHEET TITLE: SPECS SHEET 2 PROJECT 2021-- SCALE: AS NOTED ISSUE 02/21/2021 DATE: PUBLIC SAFETY D.A.S. (ERRCS) SHEET NUMBER: DAS-1 I The PSR-78-9533-X is a revolutionary digital public safety repeater designed to protect the lives of first responders and building occupants. Through the use of digital signal processing (DSP) filtering technology, the PSR-78-9533-X helps eliminate adjacent channel interference to allow band selectivity and support for 700 MHz and 800 MHz Public Safety frequencies including FirstNet. Up to two non-contiguous wideband and thirty-two non-contiguous narrowband filters can be simultaneously supported in the 700 MHz and 800 MHz Public Safety frequencies via ADRF's celebrated web -based GUI, which provides versatility and total control to the user. The PSR-78-9533-X is the best -in -class public safety repeater with FirstNet support and it is fully compliant with International Fire Code (IFC) and National Fire Protection Association (NFPA). ® Tested and approved under UL 2524, Second Edition by MET Laboratories, Inc. as comprehensive solution with an annunciator and ADRF BBx Series battery backups 0 NFPA 72 2016 code compliant and FirstNet compliant m Alarming output to supervised circuits for: antenna, amplifier, AC or DC power supply, battery, and charger failure including oscillation detection with automatic amplifier shutdown routine 10 Type 4 (ULSO/ULSOE) Enclosure ® Simultaneously supports FCC Part 90 Class A narrowband and Class B wideband repeater designations • Up to 95 dB of gain and up to 33 dBm downlink and 30 dBm uplink output power per band ® Supports both analog and digital systems Ceiling Mount Omni MODEL: TA-0727-1 Excellent coverage for public safety frequencies flush mounted on a roof top ceiling. FREQUENCY RANGE (MHZ) GAIN TYPE BEAM WIDTH POLARIZATION CONNECTOR MOUNTING MOUNTING LOCATION IMPEDENCE PIM VSWR 700-2700 MHz 4 dBi Omni -Directional 360° Horizontal N-Female or F-Female Ceiling Indoor 50 Ohm .053 1.4:1 MAX POWER 100 W GROUND DC DIMENSIONS 7"0"0" WEIGHT 8 Oz MATERIALS ABS,RAL9003 OPERATING TEMP -40° to 140° F INGRESSION PROTECTION IP65 COLOR White MODEL TA-0727-1 N / TA-0727-1 F Technical Antennas 9500 NW 12 ST #5 Doral, FL 33172 1 Tel. 305-680-3995 Designed and engineered in Miami, Florida USA. For more information, please visit www.technicalantennas.com Product Specifications PSR-78-9533-X (Public Safety 700/800 MHz Channelized Digital Repeater) Electronic Specifications Downlink Uplink Frequency Range FirstNet+ PS 700 758 - 768 MHz 788 - 798 MHz 769 - 775 MHz 799 - 805 MHz PS 800 851 - 861 MHz 806 - 816 MHz FirstNet / PS 700 / FirstNet + PS 700 33 dBm 30 dBm Composite Output Power PS 800 33 dBm 30 dBm FirstNet + PS 700 + PS 800 36 dBm (33dBm + 33dBm) 30 dBm System Gain 95 dB 95clB Wideband 2 (non-contiguous) Narrowband (N Mode) Up to 16 (non-contiguous) @ PS 700 Up to 16 (non-contiguous) @ PS 800 Filter Selection Narrowband (S1 Mode) Up to 12 (non-contiguous) @ PS 700 Up to 20 (non-contiguous) @ PS 800 Narrowband (S7 Mode) Up to 32 (non-contiguous) @ PS 700 Narrowband (S8 Mode) Up to 32 (non-contiguous) @ PS 800 Wideband 3, 5, 10 MHz Filter Bandwidth Narrowband 12.5, 25, 75, 100, 150, 200 KHz Wideband 60 dBc @ Filter Bandwidth Edge + 1 MHz Filter Roll -off Narrowband >_ 60 dBc @ Filter Bandwidth Edge + 3 x Filter BW Spurious Emission FCC Rule Compliant Passband Ripple ± 2 dB ALC Dynamic Range >_ 60 dB Gain Dynamic Range >_ 45 dB Noise Figure @ Max. Gain <5 dB Wideband <6 µs System Group Delay Narrowband < 46 µs @ 12.5 KHz, < 28 µs @ 25 KHz, < 18 µs @ 75 KHz, < 15 µs @ 100 KHz, s 13 µs @ 150 KHz, s 12 µs @ 200 KHz Power Supply 110 - 240 VAC; 60 Hz (Free Voltage, w/ battery backup function) Power Consumption < 163 W Max RF Input Power without Over Drive -20 dBm Enclosure Cooling Convection Max RF Input Power without Damage +10 dBm Impedance 500 VSWR < 1.5 : 1 Dry Contacts NFPA 1221 2016 Code Compliant Remote Alarming / Network Management Dry Contacts, Web -GUI, SNMP (External Wireless Modem Required) Humidity 5% - 95% RH Condensed Operating Temperature - -40'F to +140°F (-40'C to +60'C) Certification MET Classified for UL 2524 Fire & Shock I FCC: Part 90 Class A / Class B Annunciator Decibel Level 100 dB @ 1m Uplink Squelch Control Narrowband / Broadband: -110 to -80 dBm (5 dB step) Mechanical Specifications Dimension (Repeater IAnnunciator) 11.0 x 9.0 x 21.3 in (w/o bracket) 15.91 x 2.84 x 6.32 in (w/o bracket) Weight (Repeater I Annunciator) 55 Ibs (w/o bracket) 12.5 Ibs (w/o bracket) RF Connector 4.3-10 (Female) Weather Resistance Type 4 (UL50/UL50E) MAXIMUM CHARACTERISTICS APPLICATION: DC SHORT/RF ONLY (NO POWER SUPPLY PROVISIONS) BULKHEAD MOUNT BI-DIRECTIONAL WEATHERPROOF WHEN INSTALLED FREQUENCY RANGE: 698MHz TO 2.7GHz @ -26dB RETURN LOSS MAX SURGE: IEC 61000-4-5 8/20ps WAVEFORM 40kA MAX 20kA MULTIPLE INSERTION LOSS: 50.1 dB CONTINUOUS POWER: 50OW @ 920MHz (750W @ 50-C) LET THROUGH VOLTAGE: :5±200mV FOR 3kA @ 8/20Ns WAVEFORM THROUGHPUT ENERGY: 55nJ FOR 3kA @ 8/2011s WAVEFORM TEMPERATURE: -50'C TO +85'C STORAGE/OPERATING VIBRATION: 1 G @ 5Hz TO 10OHz MATERIAL: BODY: TRI-PLATED BRASS PTFE: DIELECTRIC CENTER PINS: TRI-M ENVIRONMENTAL: MEETS IEC 60529 IP67 WHEN CONNECTED MEETS BELLCORE #TA-NWT-000487 PROCEDURE 4.11, 12OMPH WIND DRIVEN RAIN INTRUSION TEST CE COMPLIANT ROHS COMPLIANT Q 2015 PotyPhaser. All rights reserved. 2X 5/8-24 UNEF-2A FEMALE 'N' CONN HARDWARE KIT INCLUDES: QTY DESCRIPTION 1 NUT 5/8-24 303 HEX SS 1 WASHER 5/8 410 SS 1 SILICONE O-RING 019 0-9- _M Tech n i cal 1 U OLM) I c:; I'( �e t %Ma 700/800 Donor Antenna MODEL: TA-78-1 Long lasting outdoor high gain panel for years of use on the 700 & 800 Mhz band. FREQUENCY RANGE (MHZ) 710-895 GAIN TYPE 08 dBi Directional BEAM WIDTH 60' POLARIZATION CONNECTOR Horizontal or Vertical N-Female MOUNTING Pole MOUNTING LOCATION IMPEDENCE FRONT -TO -BACK RATIO Outdoor 50 Ohm 20 dB VSWR MAX POWER 1 *1 100 W GROUND DC DIMENSIONS 9.5" x 9.5" x 0.8" WEIGHT MATERIALS OPERATING TEMP WIND VELOCITY RATING COLOR — MODEL 1.2 Lbs Alluminum, ADS UV Stable -40' to 140' F 180 mph White TA-78-1 Technical Antennas 9500 NW 12 ST #5 Doral, FL 33172 { Tel. 305-680-3995 Designed and engineered in Miami, Florida USA. For more information, please visit www.tecllnicalantennas.com 2X .95[ 24.1 ] REVISIONS REV. DESCRIPTION ECN DATE APPROVED E REFER TO ECN 12864 9/9/14 JJ 01.18[30] 5] CUSTOMER APPROVAL: DATE: ALL DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. UNLESS OTHERWISE SPECIFIED DRAWN DATE LEADING DIMENSIONS ARE INCHES RD 02/09l2012 DIMENSIONS IN [ ]ARE MILLIMETERS ENG APPD i-P*rP_h1CtSPJ JJ 5/15/12 TOLERANCES: PRODUCT MGR FRACTIONS=± 1/32 .XX=± .03 CP 5/15/12 TITLE ANGLES=± 1 ' .XXX=± .010 MARKETINGAPPD BI-DIRECTIONAL BROADBAND DC MATERIAL LJ 5/15/12 PROJECT NO. SHORT FILTER'N' CUSTOMER SPECIFICATION THESE COMMODITIES, TECHNOLOGY OR THIRD -ANGLE PROJECTION NOTICE: THE INFORMATION AND DESIGN SIZE CAGE PART NUMBER REV SOFTWARE WERE EXPORTED FROM THE UNITED STATES IN ACCORDANCE WITH THE IN THIS DOCUMENT IS THE PROPERTY B 30992 TSX-N F F E EXPORT ADMINISTRATION REGULATIONS. - O OF TRANSTECTOR SYSTEMS. ALL DIVERSION CONTRARY TO U.S. LAW PROHIBITED. RIGHTS RESERVED. SCALE PROD CAT 1:1 RFP DOCUMENT NAME TSX-NFF-C SHEET OF 1 BDA SYSTEMS CO. PH: 9500 NW 12thS 1(855)756-0225 STE. 5 DORAL, FL - 33172 CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF BDA SYSTEM CO. JJ CONSULTING GROUP, INC. DA LIOENBE #31 838 JORC3E J. SALMADD, P.E. #63600 2001 TIZEWELL Dr RULE x #iaov ❑RLANDO, FL 38937 PROFESSIONAL SEAL: 0 i No. 3 ��. ST f @F (V\ n�� ORIOP•'G����� rc4m000 #PG00061851 PROJECT INFORMATION: WLO CO �ILL_ 0 0 J moo= Q ry Q i- LLJ LLB i0 Q Li— J Cn U_ Q J CD Im `� cY) REVISION: # I DATE DESCRIPTION SHEET TI TLE: SPECS SHEET 3 PROJECT 2021-- SCALE: AS NOTED ISSUE 02/2112021 DATE: PUBLIC SAFETY D.A.S. (ERRCS) SHEET NUMBER: DAS-12