HomeMy WebLinkAbout7646 Gall Blvd (3)V NOTE: PIPE LENGTHS INDICATED ARE CUT LENGTHS. FIRE PROTECTION FL001 SCALE: 1 /8" = 1'-0" 0 4 8 16 32 GRAPHIC SCALE: 1 /8" = 1'— 0" Job: CHIPOTLE at ZEPHYR COMMONS Address: 7646 GALL BLVD. City: ZEPHYRHILLS State: FLORIDA Zip/Postal Code: 33541 Contract #: TM1895 Date: 8/13/21 Contractor: VSC FIRE & SCURITY Designer: MBH Address: 6901 BRYAN DAIRY BLVD., #110 City: LARGO State: FLORIDA Zip/Postal Code: 33777 Phone: 727456-5200 Fax: 727456-5201 Email: Approving Authority: PASCO COUNTY Design Defaults Standards: 2016 NFPA 13 Default Sprig Size: 1 Default Drop Size: 1 Default Sprig Material: 40 Default Drop Material: 40 Default Sprig Elevation: *9. Default Drop Elevation: 810. oNETYPE INDICATES FIREr PROPOSED CHIPOTLE TOTAL AREA 2,291 S.F. SPRINKLER LEGEND — SHELL / CHIPOTLE SYM QTY POSITION FINISH TEMP K NPT SIN MANUF. MODEL# DESCRIPTION QO 60 UPRIGHT BRASS 200 8.0 3/4" R3622 RELIABLE 171 FR—LO EXISTING, EXPOSED UPRIGHT, Q.R., STD. COVERAGE, 1" SPRIG WITHIN 12" OF DECK. 17 PENDENT WHITE 200 8.0 3/4" R3612 RELIABLE F1FR—LO SEMI —RECESSED, Q.R., STD. COVERAGE, 1" DROP TO CEILING. 2 PENDENT CHROME 200 8.0 3/4" RA6112 RELIABLE F3QR80—DRY DRY PENDENT USING TWO—PIECE CHROME ESCUTCHEON, "HB", Q.R., STD. COVERAGE. 19 = TOTAL NEW SPRINKLERS IN THIS PROJECT. a IY'& y�� 8/13/21 SLOPE LESS THAN 1:12 ROOF DECK SPRINKLER DEFLECTOR WITHIN 12" OF DECK. (TYP) 212 1 212 212 BUILDING SECTION - SCALE: e CO t TO SYSTEMCn `V �I 4" FLOW SWITCH. (WIRING BY OTHERS) 4" SHOTGUN CHECK I t VALVE WITH TRIM. LO 4" BIFLY (WIRING BY OTHERS)LVE S I z 0 t 2 �- �I N O I � t FINISHED FLOOR t t t t t t t t Cot t t t t t t t t t FROM SUPPLY 1" INSPECTOR'S TEST VALVE. AGF 1000 WITH 17/32" ORIFICE. 2" GALV MAIN DRAIN PIPING THRU WALL AT 1'-0" A.F.G. TO 2" GALV THRD 45 ELL. VSC FIRE POINT OF OF CONNECTION AT 11-1 /2" A.F.F. 6 x 4" GRVD CONIC. REDUCER. NOTE" PIPE LENGTHS INDICATED ARE CUT LENGTHS. EXISTING RISER DETAIL SCALE: 1 /4" = 1'-0" 0 2 4 8 16 GRAPHIC SCALE: 1 /4" = 1'— 0" REVIEW DATE 8 _'1 —1', ` L'' CITY OF ZEPHYRHILLS bt FIRE AND LIFE SAFETY EXAMINER_ ALL WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS �o t CORRUGATED DECK SLOPE LESS THAN 1:12 r ­7 0 / ('( �EN _WEB JOIST 212 t12 OR I —BEAM 3/8" BEAM CLAMP. N 3/8" ALL THREAD ROD FOR 1" THROUGH 4" 2-1/2" MAIN TO RISER ROOM. ADJUSTABLE SWIVEL LOOP RING PIPE SIZES 1" — 4" = 3/8" ALL THREAD ROD TYPICAL HANGER DETAIL, NOT TO SCALE GENERAL NOTES: 1. SPRINKLER SYSTEM SHALL COMPLY WITH THE FLORIDA FIRE PREVENTION CODE, 7'fH EDITION (2020) AND 2016 NFPA 13. VSC FIRE'S POINT OF CONNECTION IS WITHIN EXISTING BUILDING AND NEW TENANT SPACE, 2. SPRINKLER HEADS SHALL BE ORIFICE, STYLE AND TEMPERATURE PER NFPA 13 REQUIREMENTS. SEE SPRINKLER HEAD LEGEND ON THIS SHEET. 3. SYSTEM TEST SHALL BE WITNESSED BY PASCO COUNTY / CITY OF ZEPHYRHILLS AHJ PRIOR TO ANY PORTION BEING CONCEALED. GENERAL CONTRACTOR SHALL GIVE VSC FIRE 72 HRS NOTICE PRIOR TO REQUESTING AN AREA BEING TESTED. GENERAL CONTRACTOR SHALL NOTIFY OTHERS WHO WOULD LIKE TO BE PRESENT TO WITNESS SYSTEM TEST/INSPECTION. 4. HANGERS TO BE PER DETAILS ON THIS SHEET. HANGERS SHALL BE SPACED IN ACCORDANCE WITH NFPA 13 REQUIREMENTS. 5. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES. 6. THE OWNER IS RESPONSIBLE FOR PROVIDING AND MAINTAINING ADEQUATE HEAT TO PROTECT WET SYSTEM FROM FREEZING. 7. PIPING EXPOSED TO WEATHER SHALL BE GALVANIZED. GALVANIZED GROOVED PIPING SHALL BE INSTALLED USING MANUFACTURER'S PAINTED GROOVED FITTINGS PER NFPA 13. GALVANIZED THREADED PIPING SHALL BE INSTALLED USING GALVANIZED MALLEABLE IRON FITTINGS. ALL PIPING WITHIN STRUCTURE SHALL BE BLACK SCHEDULE 10/40. 8. GROOVED PIPING 1-1/2" AND LARGER SHALL BE BLACK SCHEDULE 10 WITH THREAD—O—LETS OR GROOVE—O—LETS. THREADED PIPING 1" THRU 2" SHALL BE BLACK OR GALVANIZED SCHED 40. 9. RATED PARTITIONS ARE INDICATED ON PLANS. SEE UL FIRESTOP DETAILS IN SUBMITTALS. 10. FLOW AND TAMPER SWITCHES ARE EXISTING TO REMAIN. INTERNAL DIAMETER SCHED 40 PIPING (THRD & GRVD) 1" ACTUAL I.D. = 1.049 1-1 /4" ACTUAL I.D. = 1.380 1-1 /2" ACTUAL I.D. = 1.610 2" ACTUAL I.D. = 2.067 2-1/2" ACTUAL I.D. = 2.469 4" ACTUAL I.D. = 4.026 FOREMAN NOTE: PIPE & FITTING NOTES D E S I G N C R I T E R I A Plot Date: 8/13/2021 9:32 AM SPRINKLER HEAD LOCATIONS IN AREAS WITH SUSPENDED Florida Certificate of Competency ACCOUSTICAL CEILING TILES ARE SHOWN IN CENTER OF TILE FOR Contractor I - FPC21-000041 � LINE PIPING TO BE SCHED 40 WITH DUCTILE IRON/CAST IRON OR GALV MALLEABLE IRON FITTINGS TYPE SYSTEM: ET ]DRY QPRE-ACTION NFPA STANDARD: 16:NFPA 13 E:]16:NFPA 14 016:NFPA 20 []16:NFPA 24 BY DESIGN PURPOSES. THESE HEADS ARE NOT REQUIRED TO BE Martin B Hoglievina OCCUPANCY: MERCANTILE APPROVING AUTHORITY: PASCO COUNTY CENTERED IN CEILING TILES PER CONTRACT SPECIFICATIONS. Moo LINE PIPING TO BE SCHED 10 WITH GROOVE-O-LETS OR THREAD-O-LETS HAZARD: O.H. II APPLICABLE CODE: FFPC 7TH EDITION (2020). *IMPORTANT* �j ALL MAIN PIPING TO BE SCHED 10 WITH GROOVE-O-LETS OR THREAD-O-LETS THE OWNER HAS THE RESPONSIBILITY OF PROVIDING FREEZE PROTECTION IN AREAS THAT HAVE A WET PIPE SPRINKLER SYSTEM DENSITY: 0.20 GPM/SO.FT. AS WELL AS A SUITABLE HEATED ENCLOSURE FOR DRY PIPE, DELUGE OR ANY OTHER TYPE VALVE CONTROLLING WATER SUPPLIES ALL MAIN PIPING TO BE WITH STANDARD 125# THREADED FITTINGS TO AUTOMATIC SPRINKLER SYSTEMS. REMOTE AREA: AS INDICATED SO. FT. HANGER NOTES N © 2021 VSC FIRE & SECURITY, INC. —� DENOTES HANGER LOCATION BEAM CLAMP, PIPE RING, & ATR MAX. S.F./HD.:� 30 VSC FIRE & SECURITY, INC. EXPRESSLY RESERVES ITS RIGHTS UNDER COMMON LAW COPYRIGHT LAWS AND ALSO RESERVES ALL OTHER TOTAL HOSE STREAM: 100 GPM 250 GPM PROPERTY RIGHTS IN WITH THE OWNERSHIP OF THESE DRAWINGS AND/OR THESE DRAWINGS AND/OR DENOTES TRAPEZE HANGER LOCATION ❑ CONCRETE ANCHOR, PIPE RING, &ATR 500 GPM 750 GPM 1000 GPM CHANGED, OR COPIED N ANY FORM OR MADNOCUMENTS. DOCUMENTS NOT BEMNECTION USED, REPRODUCED, NER WHATSOEVER NOR SHALL THEY BE 3/8 ATR 1 4 PIPE 1/2 ATR 6 & 8 PIPE WOOD HANGER ASSEMBLY, SEE DETAIL ASSIGNED TO ANY THIRD PARTY WITHOUT THE EXPRESS WRITTEN CONSENT OF VSC FIRE & SECURITY, INC. WHICH CONSENT VSC FIRE & LOCAL HOSE THREAD: MNST NORTH SECURITY, INC. SHALL NOT BE OBLIGATED TO GRANT. ALL RIGHTS RESERVED. I--) STAINLESS STEEL HANGER ASSEMBLY INTERNAL DIAMETER SCHED 10 PIPING (GRVD ONLY) 1-1/2" ACTUAL I.D. = 1.682 2" ACTUAL I.D. = 2.157 2-1/2- ACTUAL I.D. = 2.635 3" ACTUAL I.D. = 3.260 4" ACTUAL I.D. = 4.260 6" ACTUAL I.D. = 6.357 Im SUBMITTAL VSC VSC FIRE • SECURITY, INC. YOUR WORLD. PROTECTED. COMPLETE FIRE PROTECTION AND LIFE SAFETY SYSTEMS SINCE 1958 FIRE • SECURITY WEB SITE ADDRESS: http://Www.vscfs.com TAMPA OFFICE 6901 BRYAN DAIRY ROAD - SUITE 110 LARGO, FL 33777 (727) 456-5200 • FAX (727) 456-5201 R E V I S 10 N S Plotted By: Martin Hoglievina DESCRIPTION DATE # 0 0 • VIRGINIA • MARYLAND • NORTH CAROLINA • SOUTH CAROLINA • • GEORGIA •FLORIDA • ARKANSAS • ALABAMA • JOB No. TM1895 FLOOR PLAN AND SECTION SHEET No. FP-1 DATE 8/13/21 CHIPOTLE RESTAURANT 7646 Gall Blvd Zephyrhills, FLORIDA 33541 G.C. - Xonstructors DESIGNER SCALE MBH AS INDICATED 0