HomeMy WebLinkAboutUS 301 Pretty Pond RdNOTE: CONTRACTOR SHALL COMPLY WITH OSHA'S STANDARDS 29 CFR PART 1926, SUBPART CC FOR VERTICAL AND HORIZONTAL CLEARANCES TO THE OVERHEAD DISTRIBUTION AND TRANSMISSION POWER LINES. FDOT DATA.- RT./LT. RDWY. / SR 39 / US 301 (GALL BOULEVARD) / MP 7.362-7.419 / 45 MPH HWY SEGMENT #14-050-0000 (PERMIT NO. 2021-A-798-00003/2021-D-798-00003 APPLICANT: SCOTT K. STANNARD, P.E. (AGENT FOR MQ. DEVELOPMENT) LOCATION: 7553 GALL BOULEVARD, ZEPHYRHILLS, FL 33541 F F%%JJL-", i um $ 71 PROPERTY OWNER/DEVELOPER: WILSON DEVELOPMENT GROUP, LLC 3715 NORTHSIDE PKWY N.W. BUILDING 400, SUITE 515 ATLANTA, GA 30327 PROPERTY LOCATION: NW CORNER OF PRETTY POND ROAD AND GALL BLVD SIZE: 8.56 ACRES PARCEL ID: 34-25-21-0010-04900-0000 34-25-21-0010-05000-0010 34-25-21-0010-06300-0010 34-25-21-0010-06400-0000 LEGAL DESCRIPTION: SEE BOUNDARY SURVEY PROPERTY ZONING: C-2 COMMUNITY COMMERCIAL BUILDING SETBACK REQUIREMENTS FRONT: 30 FT SIDE: 0 FT REAR: 20 FT PROPERTY USE EXISTING PROPOSED USE: VACANT RETAIL MAXIMUM BUILDING HEIGHT ALLOWED PROPOSED HEIGHT: 30 FT 30 FT FLOOD ZONE: THIS PROPERTY LIES IN FLOOD ZONE & 11AE" EL. 120.8 AS PER FEMA FLOOD INSURANCE RATE MAP; COMMUNITY PANEL NO. 12101CO289F, DATED 09/26114. THE PORTION OF THE REMAINDER LIES IN ZONE X ENGINEER: QC55 Commercial Site Solutions, Inc. ENGINEERING • 1.AN17SCAPF: ARC1117'r-(7S 402 EAST I S-I' AVENU F 21704 STA'm ROAD 54 EASLEY, SC 29640 LUTTZ, FL 33549 864-85 - 200 S 13-885-2032 SITE DEVELOPMENT PLANS bp z"�' US 301 AT PRETTY POND ROAD ZEPHYRHILLS, TRACT 64 r [--,6 Z'( AGENCY AND UTILITY CONTACTS CONTACT LIST DRAWING LIST SHEET CITY PLANNING DEPARTMENT: 5335 8th STREET ZEPHYRHILLS, FL 33542 PHONE: (813) 780-0006 CONTACT: TODD VANDE BERG, DIR EMAIL: CITY UTILITIES DEPARTMENT: 39825 ALSTON AVENUE ZEPHYRHILLS, FL 33542 CONTACT: JOHN BOSTIC PHONE: (813) 780-0029 EMAIL: ***CAUTION*** st1: UTILITY LOCATOR SERA 3 DAYS EEF-(E 043 - TOLL FREE1-(saf) 43z4770 il A OW CALL SYSTEM FOR COMMUNITY AND JOB SAFETY. - CALLVOM THE VMOERIROMNO UW= SOM HAVE GM LACAIM FROM FOS SURVEY MIF108h I M 96 EN8 W OR,UE = TIE 9X"EYOB MAMFS NO OUANAMM MT TIE VNOE�UID UM MS 9 WN COMPRISE ALL SUCH VnmLs w THE AREA, amm N SERMM OR ABAFDd18J. THE NAMMIR FIRR m ow NOT WMUt ULT MAT THE UMDER9ROLLMi UFAAn 94OMN ARE RI THE 0= LOCATIOM 00M IM ALTI MMN ME DOES CERTIFY THAT TMEY ARE LOCATEB AS ACCUtlSTB.Y AS MORE FROM SWO MIAI M AVALAMME. ME 2Xr4EYW NM MOT PMYWAU:.Y LOCOM 9E CITY BUILDING DEPARTMENT: 5335 8th STREET ZEPHYRHILLS, FL 33542 PHONE: (813) 780-0020 CONTACT: BILL BURGESS, BLDG. OFFICIAL. EMAIL. - CITY FIRE DEPARTMENT: FIRE STATION No. 1 6907 DAIRY ROAD ZEPHYRHILLS, FL 33542 CONTACT: DANIEL SPILLMAN, FIRE CHIEF PHONE: (813) 780-0041 EMAIL_ T I PROJECT LOCATION NA � i, Ilorld:afin:a�r;�il - ,- K6 � F :1 �1 LOCATION MAP GENERAL NOTES: 1 _ INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS AND FIELD CONDITIONS WHEN POSSIBLE, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION AND ELEVATION OF ALL EXISTING UTILITIES BY DIGGING TEST PITS BY HAND AT ALL UTILITY CROSSINGS WELL IN ADVANCE OF TRENCHING. IF THE CLEARANCES ARE LESS THAN SPECIFIED ON THE PLANS OR 12", WHICHEVER IS LESS, CONTACT COMMERCIAL SITE SOLUTIONS, INC. (813-885-2032) AND OWNER PRIOR TO PROCEEDING WITH CONSTRUCTION. 2. THE CONTRACTOR SHALL INCLUDE IN HIS CONTRACT PRICE THE REMOVAL AND DISPOSAL OF ANY EXCESS TOPSOIL HE DETERMINES IS NOT REQUIRED TO PERFORM THE FINAL GRADING AND LANDSCAPING OPERATION, 3. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OF THE WORK INDICATED ON THE DRAWINGS. OWNER AND COMMERCIAL SITE SOLUTIONS, INC. ACCEPT NO RESPONSIBILITY FOR THE DESIGN TO INSTALL SAID ITEMS. 4. CALL FLORIDA ONE CALL: UTILITY LOCATOR SERVICE 72 HOURS IN ADVANCE OF DIGGING AT 1-800-432-4770. 5. ALL WORK SHALL CONFORM TO THE CITY OF ZEPHYRHILLS STANDARDS AND SPECIFICATIONS. 6, ALL CURB/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA OR THE CITY OF ZEPHYRHILLS STANDARDS, WHICHEVER IS MORE RESTRICTIVE. 7. PRE -CAST DRAINAGE AND SANITARY SEWER STRUCTURES HAVE BEEN SPECIFIED ON THE PLANS. OWNER AND COMMERCIAL SITE SOLUTIONS, INC., HOWEVER, ASSUME NO RESPONSIBILITY FOR THESE STRUCTURES AS FIELD CONDITIONS DURING CONSTRUCTION OFTEN DICTATE MINOR ELEVATION ADJUSTMENTS. THE CONTRACTOR ASSUMES ALL RESPONSIBILITY AND EXPENSE FOR MODIFYING THESE STRUCTURES TO ACCOMMODATE THESE FIELD ADJUSTMENTS. 8. THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE DAILY RECORD KEEPING OF THE AS -BUILT CONDITION OF ALL OF THE UNDERGROUND UTILITIES, CONSTRUCTION STAKEOUT ASSOCIATED WITH THE PROJECT, PREPARATION OF THE NECESSARY/REQUIRED AS -BUILT WATER AND SEWER PLANS TO BE SUBMITTED TO THE CITY OF ZEPHYRHILLS AND/OR THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION, AND ALL OTHER INFORMATION REQUIRED IN CONNECTION WITH OBTAINING PERMITS TO OPERATE AND RELEASE OF BONDS. 9. ALL WATER LINE AND SEWER LINE INSTALLATION SHALL CONFORM TO THE STANDARDS AND DETAILS OF THE CITY OF ZEPHYRHILLS AND THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION CONSTRUCTION PERMIT. 10. A COPY OF THE FINANCIAL RESPONSIBILITY FORM AND THE STORM WATER POLLUTION PREVENTION PLAN MUST BE KEPT ON THE WORK SITE AND SHOWN UPON REQUEST. 11. THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE ALL MATERIAL AND LABOR ASSOCIATED WITH THE TESTING OF THE WATER AND SEWER LINES REQUIRED BY THE CITY OF ZEPHYRHILLS PUBLIC WORKS DEPARTMENT AND/OR FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION. 12. THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE ANY DE -WATERING NECESSARY TO CONSTRUCT THE PROJECT AS SHOWN ON THE PLANS, INCLUDING PERMITTING PRICE. 13. SEDIMENT CONTROL MEASURES MUST BE INSPECTED AND MAINTAINED REGULARLY TO INSURE THAT THE INTENDED PURPOSES ARE ACCOMPLISHED. OWNER/DEVELOPER: WLN ZEPHYRHILLS, LLC CONTACT: KEVIN FRAZIER 3715 NORTHSIDE PARKWAY NW BUILDING 400, SUITE 515 ATLANTA, GA 30327 PHONE: (404) 228-4364 EMAIL: ENGINEER: COMMERCIAL SITE SOLUTIONS. INC. CONTACT: SCOTT STANNARD, PE 21764 STATE ROAD 54 LUTZ, FL 33549 PHONE: (813) 885-2032 EMAIL: sstannard@css-eng_cam 14. ALL DRAINAGE STRUCTURES MUST MEET FDOT AND THE CITY OF ZEPHYRHILLS STANDARD SPECIFICATIONS. 15. ALL SITE WORK FOR THIS PROJECT SHALL MEET OR EXCEED THE PROVIDED SITE WORK SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE FOR TRAFFIC CONTROL WITHIN RIGHT OF WAY. THIS IS TO BE DONE IN ACCORDANCE WITH M.U_T.C.D. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR RAZING AND REMOVAL OF THE EXISTING STRUCTURES, RELATED UTILITIES, PAVING, UNDERGROUND STORAGE TANKS AND ANY OTHER EXISTING IMPROVEMENTS AS NOTED. (BY OTHERS) 17. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM PREVIOUS AND CURRENT DEMOLITION OPERATIONS. DISPOSAL WILL BE IN ACCORDANCE WITH ALL LOCAL, STATE AND/OR FEDERAL REGULATIONS GOVERNING SUCH OPERATIONS. (BY OTHERS) 18. THE GENERAL CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR AND SHALL TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES DURING THE CONSTRUCTION PHASES OF THIS PROJECT. 19. ANY/ALL CONSTRUCTION WITHIN STATE HIGHWAY DEPARTMENT RIGHT-OF-WAY SHALL BE COORDINATED WITH THE HIGHWAY DEPARTMENT RESIDENT MAINTENANCE ENGINEER. 20. ALL SITE WORK FOR THIS PROJECT SHALL MEET OR EXCEED THE SPECIFICATIONS OF THE RELEVANT UTILITY COMPANY OR REGULATORY AUTHORITY, AND THE SPECIFICATIONS FOR THE CONSTRUCTION OF THEEXISTING IMPROVEMENTS WHICH ARE BEING ALTERED OR REPLACED. CONTRACTOR SHALL CONTACT THE ENGINEER FOR SPECIFICATION SECTIONS FOR ITEMS SUCH AS LANDSCAPING AND IRRIGATION THAT ARE AFFECTED BY THE WORK BUT NOT COMPLETELY DETAILED OR SPECIFIED ON THESE PLANS. WARRANTY/DISCLAIMER: THE DESIGNS REPRESENTED IN THESE PLANS ARE IN ACCORDANCE WITH ESTABLISHED PRACTICES OF CIVIL ENGINEERING FOR THE DESIGN FUNCTIONS AND USES INTENDED BY THE OWNER AT THIS TIME. HOWEVER, NEITHER THE ENGINEER NOR ITS PERSONNEL CAN OR DO WARRANT THESE DESIGNS OR PLANS AS CONSTRUCTED EXCEPT IN THE SPECIFIC CASES WHERE THE ENGINEER INSPECTS AND CONTROLS THE PHYSICAL CONSTRUCTION ON A CONTEMPORARY BASIS AT THE SITE. SAFETY NOTICE TO CONTRACTOR: IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. ANY CONSTRUCTION OBSERVATION BY THE ENGINEER OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, ON OR NEAR THE CONSTRUCTION SITE. COVER SHEET C-1.0 GENERAL NOTES C-1.1 EXISTING CONDITIONS C--2.0 DEMOLITION PLAN C-3.0 SITE PLAN C-4.0 TRUCK TURNING PLAN C-4.1 SITE DETAILS C-5.0, 5.1, 5.2, 5.3 GRADING PLAN C-6.0 STORM DRAIN PROFILES C-6.1, 6.2 STORM DRAIN DETAILS C-7.0 GRADING & SECTIONS C-8.0, 8.1 SWPP PLAN C-9.0 EROSION CONTROL PLAN PHASE 1 C-9.1 EROSION CONTROL PLAN PHASE II C-9.2 EROSION CONTROL DETAILS C-10.0, 10A, 10.2 UTILITY PLAN C-11.0 UTILITY CROSSING DETAILS C-11.1 UTILITY DETAILS C-12.0, 12.1, 12.2, 12.3. 12.4 LIFT STATION DETAILS C-12.5 TURN LANE DEMOLITION C-13.0 TURN LANE STRIPING & STAKING C-13.1 TURNLANE GRADING PLAN C-13.2 TURN LANE UTILITY PLAN C-13.3 TURN LANE SECTIONS C-1 3.4,13.5,13.6 LANDSCAPE PLAN L-1.0 LANDSCAPE DETAILS L-2.0 IRRIGATION PLAN IR-1 IRRIGATION DETAILS IR-2 REV ISIONS/SUBNil TT S. 01 /15/20 - ISSUED FOR PERMITS 03/30/21 - SWFWMD/FDOT RESUBMITTAL 04/28/21 - FDOT RESUBMITTAL 05/14/21 - CITY OF ZEPHYRHILLS RESUBMITTAL OWNER/DEVELOPER: WLN ZEPHYRHILLS, LLC 3715 NORTHSIDE PKWY NW BUILDING 400, SUITE 515 ATLANTA, GA 30327 PH: (404) 228-4364 CONTACT: KEVIN FRAZIER GENERAL DEMOLITION NOTES A. CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF THE EXISTING ITEMS AS SHOWN AND ANY OTHER EXISTING IMPROVEMENTS AS NOTED, SUCH THAT THE IMPROVEMENTS SHOWN ON THE REMAINING PLANS CAN BE CONSTRUCTED. B. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM PREVIOUS AND CURRENT DEMOLITION OPERATIONS, DISPOSAL WILL BE IN ACCORDANCE WITH ALL LOCAL, STATE AND/OR FEDERAL REGULATIONS GOVERNING SUCH OPERATIONS. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS REQUIRED FOR DEMOLITION AND DISPOSAL. C. THE GENERAL CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES DURING THE CONSTRUCTION PHASES OF THIS PROJECT. THE CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR ANY DAMAGES TO THE ADJACENT PROPERTIES OCCURRING DURING THE CONSTRUCTION PHASES OF THIS PROJECT. D. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION ANDIOR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IF CLEARANCES ARE LESS THAN SPECIFIED ON THE PLAN OR TWELVE INCHES (12"), WHICHEVER IS LESS, CONTACT THE DESIGN ENGINEER AND THE OWNER PRIOR TO PROCEEDING WITH CONSTRUCTION. E. IF DEMOLITION OR CONSTRUCTION ON SITE WILL INTERFERE WITH THE ADJACENT PROPERTY OWNER'S TRAFFIC FLOW, THE CONTRACTOR SHALL COORDINATE WITH THE ADJACENT PROPERTY OWNER, TO MINIMIZE THE IMPACT ON TRAFFIC FLOW. TEMPORARY RE-ROUTING OF TRAFFIC IS TO BE ACCOMPLISHED BY USING DOT APPROVED TRAFFIC BARRICADES, BARRELS, AND/OR CONES. TEMPORARY SIGNAGE AND FLAGMEN MAY BE ALSO NECESSARY. F. INTERRUPTION OF POWER TO ANY STREET LIGHT POLES OR SIGNS SHALL NOT EXCEED 24 HOURS. G. THE CONTRACTOR SHALL MAINTAIN ALL SANITARY SEWER SERVICES TO ANY "UPSTREAM" FACILITIES AT ALL TIMES. SANITARY SEWER SERVICES SHALL NOT BE INTERRUPTED AT ANY TIME DURING CONSTRUCTION ACTIVITIES. H. ALL EXISTING SEWERS, PIPING AND UTILITIES SHOWN ARE NOT TO BE INTERPRETED AS THE EXACT LOCATION, OR AS THE ONLY OBSTACLES THAT MAY OCCUR ON THE SITE, VERIFY EXISTING CONDITIONS AND PROCEED WITH CAUTION AROUND ANY ANTICIPATED FEATURES. GIVE NOTICE TO ALL UTILITY COMPANIES REGARDING DESTRUCTION AND REMOVAL OF ALL SERVICE LINES AND CAP ALL LINES BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANY CONCERNING PORTIONS OF WORK WHICH MAY BE PERFORMED BY THE UTILITY COMPANY'S FORCES AND ANY FEES WHICH ARE TO BE PAID TO THE UTILITY ILiTY COMPANY FOR THEIR V SER ICES. THE CONTRACTOR IS RESPONSIBLE FOR PAYING ALL FEES AND CHARGES. UTILITIES DETERMINED TO BE ABANDONED AND LEFT IN PLACE SHALL BE GROUTED IF UNDER BUILDING. 1. CONTRACTOR MUST PROTECT THE PUBLIC AT ALL TIMES WITH FENCING, BARRICADES, ENCLOSURES, ETC., TO THE BEST PRACTICES AND APPROVED BY OWNER/DEVELOPER CONSTRUCTION MANAGER. J PRIOR TO DEMOLITION OCCURRING, ALL EROSION CONTROL DEVICES ARE TO BE INSTALLED. REFER TO EROSION CONTROL PLAN, K. CONTRACTOR IS TO ENSURE NO DISTURBANCE OCCURS BEYOND THE LIMITS SHOWN ON THIS PLAN. GENERAL SITE NOTES A. ALL DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. B. UNLESS OTHERWISE SHOWN, CALLED OUT OR SPECIFIED HEREON ALL CURBING ADJACENT TO CONCRETE PAVING SHALL BE 6" INTEGRAL CURBING. CURB AND GUTTER NEXT TO ASPHALT SHALL BE TYPE 'D' CURB AND GUTTER. C. DEMOLITION OF EXISTING PAVEMENT AND UTILITIES IS A PART OF THIS CONSTRUCTION PACKAGE. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND STEPS TO INSURE THAT ALL ADJOINING PROPERTIES ARE PROTECTED FROM DAMAGE AND TO INSURE THAT ALL ADJOINING PROPERTIES RETAIN ALL UTILITY SERVICES DURING THE DURATION OF THE CONSTRUCTION. D. IF DEMOLITION OR CONSTRUCTION ON SITE WILL INTERFERE WITH THE ADJACENT PROPERTY OWNER'S TRAFFIC FLOW, THE CONTRACTOR SHALL COORDINATE WITH THE ADJACENT PROPERTY OWNER, TO MINIMIZE THE IMPACT ON TRAFFIC FLOW. TEMPORARY RE-ROUTING OF TRAFFIC IS TO BE ACCOMPLISHED BY USING DOT APPROVED TRAFFIC BARRICADES, BARRELS, AND/OR CONES. TEMPORARY SIGNAGE AND FLAGMEN MAY BE ALSO NECESSARY. E. CONTRACTOR TO PROTECT ALL EXISTING LANDSCAPE NOTED TO BE SAVED. F. ALL SLOPES AND AREAS DISTURBED BY CONSTRUCTION SHALL BE GRADED SMOOTH AND FOUR INCHES OF TOPSOIL APPLIED. IF ADEQUATE TOPSOIL IS NOT AVAILABLE ON SITE, THE CONTRACTOR SHALL PROVIDE TOPSOIL, APPROVED BY THE OWNER, AS NEEDED. THE AREA SHALL THEN BE SEEDED/SODDED, FERTILIZED, MULCHED, WATERED AND MAINTAINED UNTIL HARDY GRASS GROWTH IS ESTABLISHED IN ALL AREAS. ANY AREAS DISTURBED FOR ANY REASON PRIOR TO FINAL ACCEPTANCE OF THE PROJECT SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER, G. THE PROPOSED ON -SITE STORMWATER POND WILL SERVE THE ENTIRE DEVELOPMENT PROPERTY. H. THE LOCATION OF THE CONSTRUCTION FENCE ON THE DRAWINGS IS FOR GRAPHICAL REPRESENTATION ONLY. THE CONTRACTOR IS TO ENSURE THAT THE CONSTRUCTION FENCE ENCOMPASSES THE ENTIRE WORK AREA. 1. ALL DIMENSIONS, UNLESS OTHERWISE NOTED, ARE TO FACE OF CURB, OUTSIDE FACE OF BUILDING (BLOCK), OR CENTERLINE OF PARKING BAY. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF ALL ENTRY/EXIT PORCHES AND PRECISE BUILDING DIMENSIONS. J. UNLESS OTHERWISE NOTED, ON -SITE PAVEMENT SHALL BE STANDARD DUTY ASPHALT. K. ALL HANDICAP SPACES ARE TO RECEIVE A HANDICAP SIGN AND SYMBOL PAINTED ON THE ASPHALT. STALL(S) ADJACENT TO THE FIVE (5') FOOT STRIPED AISLES ARE TO RECEIVE A "VAN ACCESSIBLE" SIGN IN ADDITION TO THE ABOVE. STRIPING TO BE BLUE. L. STOP SIGNS SHALL MEET THE CRITERIA OF THE FLORIDA DEPARTMENT OF TRANSPORTATION AND MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, M. THE EARTHWORK FOR ALL BUILDING FOUNDATIONS AND SLABS SHALL BE IN ACCORDANCE WITH ARCHITECTURAL BUILDING PLANS AND SPECIFICATIONS. N. THE GENERAL CONTRACTOR IS TO COORDINATE WITH THE APPROPRIATE UTILITY COMPANIES PRIOR TO CONSTRUCTION, ADJUSTMENT, OR RELOCATION OF EXISTING UTILITIES AS DESIGNATED ON THE PLANS. 4. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING DAMAGE TO ANY EXISTING ITEM DURING CONSTRUCTION SUCH AS, BUT NOT LIMITED TO, DRAINAGE, UTILITIES, PAVEMENT, STRIPING, CURB, ETC. REPAIRS SHALL BE EQUAL TO OR BETTER THAN EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE TO DOCUMENT ALL EXISTING DAMAGE AND NOTIFY CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION START. GENERAL SITE GRADING NOTES 1. CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING UTILITIES SERVING THE STRUCTURE. UTILITIES ARE TO BE REMOVED TO THE RIGHT-OF-WAY. 2. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 3, ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. 4. PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION. 5. STORM PIPE SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED: TYPE 1: RCP, CLASS ill PER ASTM C-76, WITH FLEXIBLE PLASTIC BITUMEN GASKETS AT JOINTS, UNLESS OTHERWISE NOTED 6. EXISTING DRAINAGE STRUCTURES TO BE INSPECTED AND REPAIRED AS NEEDED, AND EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS. 7. EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1 FOOT INTERVALS. 8. PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1 FOOT INTERVALS. 9. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR BETTER. 10. ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT. 11. ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING & COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISH GRADE LIDS SHALL BE LABELED "STORM SEWER". 1 HE T A TER & CONDITIONS AS 2, T CONTRACTOR SHALL ADHERE TO ALL MS C N OUTLINED IN THE GENERAL N.P.D.E.S. PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES. 13. CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS GRADE. 14. CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS. 15. TOPOGRAPHIC INFORMATION TAKEN FROM A TOPOGRAPHIC SURVEY BY TERRAMETRIX, LLC, IF CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. 16. ALL UNSURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL APPLY STAKED SOD TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL GRASS DISTURBED AREAS IN ACCORDANCE WITH STATE SPECIFICATIONS UNTIL A HEALTHY STAND OF GRASS IS OBTAINED. IF ADEQUATE TOPSOIL IS NOT AVAILABLE ON SITE THE CONTRACTOR SHALL PROVIDE TOPSOIL, APPROVED BY THE OWNER, AS NEEDED. 17, CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO SAME. 18. ALL STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT OUT. 19. CATCH BASINS, MANHOLES, FRAMES, GRATES, SHALL MEET THE REQUIREMENTS OF THE LATEST EDITION OF THE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD PLANS FOR CONSTRUCTION AND THE CITY OF ZEPHYRHILLS REQUIREMENTS. 20. THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR THE EXACT NUMBER, SIZE AND LOCATION OF ANY ROOF DRAINS. 21. INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS AND FIELD LOCATIONS WHEN POSSIBLE, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION AND ELEVATION OF ALL EXISTING UTILITIES BY DIGGING TEST PITS BY HAND AT ALL CROSSINGS WELL IN ADVANCE OF TRENCHING. IF CLEARANCES ARE LESS THAN SPECIFIED ON THE PLAN OR TWELVE INCHES (12"), WHICHEVER IS LESS, CONTACT THE DESIGN ENGINEER AND THE OWNER PRIOR TO PROCEEDING WITH CONSTRUCTION, 22. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, BRACING, AND SPECIAL EXCAVATION MEASURES REQUIRED TO MEET OSHA, FEDERAL, STATE, AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OF ALL WORK INDICATED ON THESE DRAWINGS. THE OWNER AND THE DESIGN ENGINEER ACCEPT NO RESPONSIBILITY FOR THE DESIGNS TO INSTALL SAID ITEMS. 23. PRECAST DRAINAGE STRUCTURES HAVE BEEN SPECIFIED ON THE PLANS. THE OWNER AND THE ENGINEER, HOWEVER, ASSUME NO RESPONSIBILITY FOR THESE STRUCTURES, AS FIELD CONDITIONS OFTEN DICTATE MINOR ELEVATION ADJUSTMENTS. THE CONTRACTOR ASSUMES ALL RESPONSIBILITY AND EXPENSE FOR MODIFYING THE PRECAST STRUCTURES TO ACCOMMODATE FIELD REVISIONS. 24_ ALL SLOPES 3:1 AND STEEPER ARE TO RECEIVE STAKED SOD. 25. ALL GRADING OPERATIONS, EXCAVATIONS, FILL, COMPACTION TESTING AND BACKFILL SHALL BE OBSERVED AND TESTED BY A QUALIFIED GEOTECHNICAL ENGINEER. THE GEOTECHNICAL ENGINEER SHALL BE DESIGNATED BY AND PAID FOR BY THE OWNER. 26. NO FILL SHALL BE PLACED PRIOR TO APPROVAL OF THE SUBGRADE BY THE GEOTECHNICAL ENGINEER. 2T COMPACTION SHALL BE DONE IN ACCORDANCE WITH ALDI'S REQUIREMENTS AND THE ON -SITE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. 28. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL COSTS INCURRED FOR INSPECTION AND TESTING OF SOILS DUE TO FAILURE TO COMPLY WITH THE MINIMUM REQUIREMENTS OF THE SOILS REPORT. 29. ALL GRADING OPERATIONS SHALL BE STAKED BY A LICENSED LAND SURVEYOR PROVIDED BY THE CONTRACTOR AND APPROVED BY THE OWNER. 30. UPON COMPLETION OF THE GRADING, THE GEOTECHNICAL ENGINEER SHALL PROVIDE OWNER WITH A LETTER INDICATING THAT THE SITE AND BUILDING PAD WERE PREPARED IN DIRECT CONFORMANCE WITH THE RECOMMENDATIONS AND CONCLUSIONS IN THE SOILS REPORT. 31. CROSS -SLOPE THROUGH STRIPED AREA LEADING TO PUBLIC SIDEWALK SHALL NOT EXCEED 2.0%. 32. NO EXPOSED FOOTINGS SHALL BE ALLOWED. UTILITY NOTES 1. ALL SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE STATE OF FLORIDA AND THE CITY OF ZEPHYRHILLS UTILITIES. 2. WATER LINES SHALL BE INSTALLED WITH A MINIMUM OF 36" OF COVER UNLESS OTHERWISE NOTED. ALL WATER CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF ZEPHYRHILLS UTILITIES. 3. VALVES SHALL BE RESILIENT SEAT GATE VALVES, DIRECT BURY WITH A VALVE BOX (AWWA C509). 4. 6" WATER LINE ON -SITE SHALL BE C900 RATED PVC. ALL SERVICE LINES LESS THAN 3" IN DIAMETER SHALL BE PE. 5. SEWER LINES (INCLUDING LATERALS) SHALL BE POLYVINYL CHLORIDE (PVC) SDR 26 PER ASTM D-3034. 6. SEWER CLEANOUTS SHALL BE IN ACCORDANCE WITH THE CITY OF ZEPHYRHILLS UTILITIES DETAILS AND SPECIFICATIONS. 7. THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT UTILITY EXIT POINTS, EXIT PORCHES, ETC. 8. INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS AND FIELD LOCATIONS WHEN POSSIBLE, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION BY DIGGING TEST PITS BY HAND AT ALL UTILITY CROSSINGS WELL IN ADVANCE OF TRENCHING. IF CLEARANCES ARE LESS THAN SPECIFIED ON THE PLAN OR 12", WHICHEVER IS LESS, CONTACT THE DESIGN ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 9. ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO ANNOUNCED BUILDING POSSESSION AND/OR FINAL CONNECTION OF SERVICES, 10. A MINIMUM OF 10 FEET HORIZONTAL SEPARATION MUST BE MAINTAINED BETWEEN WATER AND SEWER LINES. THE VERTICAL SEPARATION IS TO BE A MINIMUM OF 18". 11. REFER TO THE PHOTOMETRIC AND ARCHITECTURAL PLANS FOR SITE LIGHTING ELECTRICAL DESIGN AND LAYOUT. 12. ALL SITEWORK SHALL MEET OR EXCEED THE CITY OF ZEPHYRHILLS STANDARDS AND THE SITEWORK SPECIFICATIONS. 13. CONTRACTOR TO PROVIDE ALL TRENCHING, BACKFILLING, & INSTALL ALL ELECTRICAL CONDUITS TO UTILITY COMPANY SPECIFICATIONS. 14. LOCATION OF SITE UTILITIES SHALL BE VERIFIED BY GENERAL CONTRACTOR & THE PROPER UTILITY {COMPANY PROVIDING SERVICE. 15. GENERAL CONTRACTOR SHALL PROVIDE CONCRETE APRON AT ALL CLEANOUTS OUTSIDE OF BUILDING PER CITY OF ZEPHYRHILLS STANDARD DETAIL S-14. 16. GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL TAP AND TIE ON FEES REQUIRED, AS WELL AS COST OF UNDERGROUND SERVICE CONNECTIONS TO THE BUILDING, 17. ELECTRICAL SERVICE TO PAD MOUNTED TRANSFORMER SHALL BE RUN UNDERGROUND, FROM ROAD RIGHT-OF-WAY TO BUILDING. ASSOCIATED MATERIALS AND COST BY GENERAL CONTRACTOR. 18. ALL ELECTRIC AND TELEPHONE EXTENSIONS INCLUDING SERVICE LINE SHALL BE CONSTRUCTED TO THE APPROPRIATE UTILITY COMPANY SPECIFICATIONS. ALL UTILITYDISCONNECTIONS SHALL BE COORDINATED WITH THE DESIGNATED UTILITY COMPANIES. 19. RESTRAINED JOINTS SHALL BE PROVIDED AT ALL BENDS, TEES, AND FIRE HYDRANTS. 20. DIMENSIONS SHOWN ARE TO CENTERLINE OF PIPE OR FITTING. 21. ALL TRENCHING, PIPE LAYING, AND BACKFILLING SHALL BE IN ACCORDANCE WITH FEDERAL OSHA REGULATIONS. 22. GENERAL CONTRACTOR SHALL HAVE APPROVAL OF ALL GOVERNING AGENCIES HAVING JURISDICTION OVER THIS SYSTEM PRIOR TO INSTALLATION. BROOKESVILLE OPERATIONS GENERAL NOTES: 1. ALL WORK PERFORMED IN THE DEPARTMENTS RIGHT OF WAY SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT EDITIONS OF: A. F.D.O.T. STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. B. F.D_O.T. DESIGN STANDARDS FOR DESIGN, CONSTRUCTION; MAINTENANCE AND UTILITY OPERATIONS ON THE STATE HIGHWAY SYSTEM. C. F.D.O.T. ROADWAY PLANS PREPARATION MANUAL VOLUME 1, CHAPTERS 1, 2, 4, 8, 10, 19 AND/OR 25. D. F.D.O.T. FLEXIBLE PAVEMENT DESIGN MANUAL FOR NEW CONSTRUCTION AND PAVEMENT REHABILITATION. 2. ALL AREAS IN THE FOOT RIGHT OF WAY DISTURBED DURING CONSTRUCTION SHALL BE RESTORED, COMPACTED, SODDED AND WATERED IN CONFORMANCE WITH THE FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, SECTION 570 AND 981 AND STANDARD PLANS INDEX 570-010, 3. DAYTIME WORK ONLY, BETWEEN THE HOURS OF 9:OOAM AND 3:30 PM, UNLESS OTHERWISE APPROVED BY FDOT FOR NIGHTTIME OR EXTENDED HOURS. THE F.D.O.T. ENGINEER MUST APPROVE NIGHT WORK AND LANE CLOSURES AT LEAST 48 HOURS IN ADVANCE. THE APPLICANT MUST NOTIFY THE FLORIDA DEPARTMENT OF TRANSPORTATION LOCAL MAINTENANCE OFFICE 48 HOURS IN ADVANCE OF STARTING ANY PROPOSED WORK. CALL: BROOKESVILLE OPERATIONS, PERMIT MANAGER, JAMES MEYER @ 352-848-2600. 4. ALL TRAFFIC STRIPES AND PAVEMENT MARKINGS ARE TO BE LEAD-FREE, NON -SOLVENT BASED THERMOPLASTIC. THE PERMITTEE SHALL FURNISH THE DEPARTMENT WITH THE MANUFACTURER'S CERTIFICATION THAT THE THERMOPLASTIC IS "LEAD FREE". REMOVAL OF EXISTING STRIPING SHALL BE DONE BY MILLING AND RESURFACING OF THE FRICTION/SURFACE COURSE TO OBLITERATE OBSOLETE PAVEMENT MARKINGS, 5. ALL PROPOSED TRAFFIC SIGNS AND PAVEMENT MARKINGS SHALL BE IN CONFORMANCE WITH AND CONSTRUCTED TO THE FDOT DESIGN STANDARDS INDEX SERIES 600 AND 700 SERIES. THE PROPERTY OWNER MUST MAINTAIN THE TRAFFIC SIGNS AND MARKINGS FOR THE DRIVEWAY. 6, FOR WORK WITHIN THE FDOT RIGHT-OF-WAY, THE CONTRACTOR SHALL PROVIDE A TEMPORARY TRAFFIC CONTROL PLAN PREPARED UNDER THE DIRECTION OF AND SIGNED AND SEALED BY A LICENSED FLORIDA PROFESSIONAL ENGINEER WHO IS EXPERIENCED IN PREPARING TRAFFIC CONROL PLANS AND WHO IS CERTIFIED PER FOOT PROCEDURE TOPIC NO.625-010-010. THE FOOT REQUIRES DOCUMENTATION FOR SUCCESSFUL COMPLETION OF AN APPROVED WORK ZONE TRAFFIC CONTROL TRAINING COURSE FOR THE AGENCY, UTILITY OR CONTRACTOR EMPLOYEE(S) DESIGNING, INSTALLING AND/OR MAINTAINING THE APPROVED MAINTENANCE OF TRAFFIC PLAN. DOCUMENTATION IS TO BE FURNISHED TO THE DEPARTMENT AT THE PRE -CONSTRUCTION MEETING OR BEFORE OCCUPYING STATE RIGHT-OF-WAY_ 7. MAINTENANCE OF TRAFFIC PLAN FOR WORK ZONES SHALL BE IN CONFORMANCE WITH THE REQUIREMENTS OF FOOT STANDARD PLANS INDEX 102 AND IMPLEMENTED PER THE SPECIFIC REQUIREMENTS OF THE CURRENT FDOT STANDARD PLANS INDEX 1025 ER1ESNCUDE INCLUDED WITH THESE PLANS. D 8, MAINTENANCE OF TRAFFIC PLAN MUST INCLUDE FDOT STANDARD PLANS INDEX 102-075 PEDESTRIAN CONTROL FOR CLOSURE OF SIDEWALKS. 9. ALL MATERIALS AND PRODUCTS INSTALLED IN THE FDOT RIGHT-OF-WAY (INCLUDING TACTILE SURFACES) SHALL BE IN CONFORMANCE WITH THE FDOTS APPROVED PRODUCTS LIST (APL), AND THE MATERIALS SOURCE LISTING (TIMBER AND PIPE etc.). Issued: Date: A ISSUED FOR PERMITS 01 /15/21 n CITY OF ,ZEPHYRHILLS RESUB 05/14/21 D Revisions: Date- 1 SWFWMD RESUBMITTAL 03117/21 7 FDOT RESUBMITTAL 04/22/21 2 R Scott K. Stannard, P.E. FL P.E. No. 50565 SEAL This item has been digitally signed and seated by Scott K. Stannard. P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Site Engineering • Landscape Architects Commercial Site Solutions, Inc. C.O,A NO. 27575 21764 State Road 54 Lutz, FL 33549 (813) 885-2032 www.css-eng.com ZEPHYRHILLS, LLC 3715 NORTI ISIDE PKWY NW BUILDING 4(II). SUITE MI5 ATI.ANTA, GA 30327 PI 1: (404) 225-4364 C'ONTAC1': KEVIN FRAZIL-AZ Client Name: MULTI -USE COMMERCIAL PRETTY POND RD US 11IGHWAY 101 AT PRETTY POND ZEPI IYRHILIS. F1. PI 1: 404-7:S4-6934 CONt'AC"I': MR. PFIILLIP MORRISSEY Project Name & Location: GENERAL NOTES Drawing Name - Date: 11111 /20 Revised: XXX Drawn: SKS Checked: SKS Drawing No. �Qw 1 REFER TO OFF -SITE ROAD IMPROVEMENTS FOR WORK WITHIN THE US 301 RIGHT-OF-WAY C1 COMMERCIAL (WALMART SUPER CENTER) I 5.0' .—r-- _r _.—.—..--w— ----*_--r--■--- -- --wf — — — — — - -----r---r---n----_r _rw---o—w----- i—r--- ..--s— —w10' TYPE ABUFFER I 1 10.0' 1 i I LOT 3-1.45 i i FUTURE COMMERCIALCn r 1 ` DEVELOPMENT " I I ! j f I w' 1A l I f LOT 4 - 0.43 S I f I p 19 UTILITY 2A FUTURE COMMERCIAL w � L i oi 21.5' I I z s EASEMENT LOT 1- 2.36 AC DEVELOPMENT d o I f a! I I ► I D ; FUTURE COMMERCIAL LU ' Li ( DEVELOPMENT 30.0' '- I LOT 5 - 0.93 I I � t ' FUTURE COMMERCIAL ' , i I 0 DEVELOPMENT 1E I I I � t ; i I 1D L t 2ALL 35.0' LOT LINE TA I ( I I I 11.E ' ° 2A ��'`�. I 10 H m LU HEAVY DUTY ASPHALT PAVING _'f R50.0' i o TO BE INSTALLED FOR ON -SITE N IMPROVEMENTS (TYP) w J- 35.0'R I I—y J (� 2A 10' UTILITY � R50.0' I r 1 EASEMENT 2A 7A t I PROPOSED RETAINING WALL 4A i I r TO BE DESIGNED BY OTHERS 6A �� LOT 6 - 0.98 i I Ir i RE: GRADING PLAN t I I I .- W' 6A FUTURE COMMERCIAL 1E I I `� Lu 2,aL DEVELOPMENT r I 1 _ 0 262.8' l I 0 m a I I U) Q :D PROPERTY CORNER ***CAUTION*** 7K CCACT u THEY Am La AVAR awe r LOCAIM TEE STA. 110+32.74 EXTEND EXISTING GORE STRIPING 6" DOUBLE YELLOW W/ Y/Y RPMS @ 20 CC 18" YELLOW @ 20' TYP STA. 110+60.34 / 20.798 END 35' RADIUS BEGIN 6" WHITE CONNECTING TO EXISTING STA. 110+92.12 / 47.127 PROPERTY LINE CONNECTION STA. 111+68.30 / 31.050 END 6" WHITE BEGIN 45' RADIUS STA. 111+33.92 / 47.023 PROPERTY LINE CONNECTION STA, 111+23,69 EXISTING GORE STRIPING TO BE SHORTENED 6" DOUBLE YELLOW W/ Y/Y RPMS @ 20 CC T PAVED SHOULDER, FROM OFFSET 28.050 TO 31.050 I 1 I I I 1 I I I I I I f I I I I I I PROPOSED PROPERTY LINE AFTER 11.0' ROW DEDICATION TO CITY OF ZEPHYRHLLS PROPOSED PROPERTY CORNER i I STA.. 114+54.47 / 31.050 k BEGIN PAVED +1sSHOULDER BEGIN 6" WHITE IIIIIifiiitltil TIE -LINE i S65400'16.30"E / 110.80' STATIONING TO MATCH 1 FDOT PLANS LE6ENL) PROPERTY LINE HEAVY DUTY ASPHALT PAVEMENT CONCRETE PAVEMENT / SIDEWALK NOTE: ALL STRIPING WITHIN FDOT ROW AND COUNTY ROW TO BE THERMOPLASTIC PER FDOT SPECIFICATIONS NOTE: NO DIRECT ACCESS WILL BE GIVEN FROM LOTS TO US 301 OR PRETTY POND ROAD. ALL ACCESS WILL BE SHARED ALONG CENTRAL DRIVE. NOTE: ALL FUTURE PARCELS TO PROVIDE INTERNAL ACCESS BETWEEN ALL PARCELS PER ADA REQUIREMENTS PROPERTY OWNERIDEVELOPER: WILSON DEVELOPMENT GROUP, LLC 3715 NORTHSIDE PKWY N.W. BUILDING 400, SUITE 515 ATLANTA, GA 30327 PROPERTY LOCATION: NW CORNER OF PRETTY POND ROAD AND GALL BLVD SIZE: 8.56 ACRES PARCEL ID: 34-25-21-0010-04900-0000 34-25-21-0010-05000-0010 34-25-21-0010-06300-0010 34-25-21-0010-06400-0000 LEGAL DESCRIPTION: SEE BOUNDARY SURVEY PROPERTY ZONING: C-2 COMMUNITY COMMERCIAL BUILDING SETBACK REQUIREMENTS FRONT: 30 FT SIDE: 0 FT REAR: 20 FT PROPERTY USE' EXISTING PROPOSED USE: VACANT RETAIL MAXIMUM BUILDING HEIGHT ALLOWED PROPOSED HEIGHT: 30 FT 30 FT FLOOD ZONE: THIS PROPERTY LIES IN FLOOD ZONE & "AE" EL 120-8 AS PER FEMA FLOOD INSURANCE RATE MAP; COMMUNITY PANEL NO. 12101CO289F, DATED 09/26114. THE PORTION OF THE REMAINDER LIES IN ZONE X ❑ SITE DETAILS - SEE DETAIL SHEETS 1A 6" CONCRETE CURB 1 B CONCRETE SIDEWALK PER FDOT STANDARD PLANS INDEX. 522-001 1C CONCRETE STEPS PER FDOT STANDARD PLANS INDEX 400-021 1 D 17'x10' REST AREA W/ BENCH AND BIKE RACK 1 E 10' ASPHALT SHARED USE PATH (RE: OFF -SITE ROAD PLANS) 2A TRANSITION TO TEMPORARY 4" ASPHALT CURB 4A CONCRETE UTILITY PAD 5A 3 FOOT TRANSITION FROM 0" TO 6" CURB 6A 6.0' HIGH TYPE B FENCE PER FDOT STANARD PLANS INDEX 550-002. POND FENCE SHALL BE BLACK OR GREEN VINYL COATED 7A CURB RAMP TYPE CR-E PER FDOT STANDARD PLANS INDEX 522-002 78 CURB RAMP TYPE CR-F PER FDOT STANDARD PLANS INDEX 522-002 8A SPECIAL EMPHASIS CROSSWALK PER FDOT STANDARD PLANS INDEX 711-001 30, U 25 LF OF DOUBLE YELLOW LANE STRIPING PER FDOT INDEX 711-001 SPECIAL EMPHASIS CROSSWALK IF PER FDOT INDEX 711-001 24" STOP BAR PER FDOT INDEX 711-001 0 6 C'" 7A PROPOSED 5' SIDEWALK 36" STOP SIGN PER —~—� FDOT STANDARD `r DETAILS -a 7A PROPOSED 5' SIDEWALK 0 PROPOSED 3' PAVED �— SHOULDER ON WESTBOUND LANE EXISTING STRIPING ALONG PRETTY POND ROAD TO REMAIN PRETTY POND ROAD ACCESS SCALE 1 ":20' Issued: Date: A ISSUED FOR PERMITS 01 /15/21 Ii CITY OF ZEPHYRHILLS RESUB 05/14121 Revisions: Date: 1 SWF'IP,lMD RESUBMITTAL 03/17/21 2 FDOT RESUBMITTAL 04/22/21 El N I 0 40 80 120 SCALE 1" = 40' Scott K. Stannard, P.E. FL P.E. No. 50565 SEAL This item has been digitally signed and sealed by Scott K. Stannard, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. C: Site Engineering - Landscape Architects Commercial Site Solutions, Inc. C.O.A NO. 27575 21764 State Road 54 Lutz, FL 33549 (813) 885-2032 www.Gss-eng.com WLN ZEPHYRHILLS, LLC 3715 NORTHSIDN PKWY NW BUILDING 400, SLiI'I'L 515 A"CLAN"I :A, GA 303,27 PH: (404) "128-4364 CONTAUF: KEVIN F AZIE R Client Name: MULTI -USE COMMERCIAL PRETTY POND RD LJS HIGHWAY 301 A'I' PRE'I7Y POND Zl PHYRfflLL.S. FL PI It 404-754-6934 C`ON'I`AC'I MR. PHIL.LII' MORRISSE Y Project Name & Location: SITE PLAN Drawing Name: Date: 11 /11 /20 Revised: xxx Drawn: SKS Checked: SKS Drawing No. C-4.0 NOTE: CROSS SLOPES ON ALL SIDEWALKS AND t ADA CROSSINGS SHALL NOT EXCEED 2.0%. � l o C1 COMMERCIAL (WALMART SUPER CENTER) I I 1 4 - - w - - - - - s - - - - - u - � - - � w - - - - - - - s �. - - - - - - _ - - � � �. � w � r r r �. � s .ram r r . r i - r � r - r r t � � w � _ r a � � � 1 - ! I 131 127 129 I i I 1 PROPOSED PAD I I t FFE = 128.50 I r� � 11, I 128.50 128.50 , i I " I I 129.00 s o t r ... y.. -i- 1 21 ' i i 1 1 DITCH PAVEMENT AND SODDING I PER FOOT PLANS INDEX 524-001 I I 128.00 � � EXTEND EXISTING (2) 30" RCP DRAIN 0 15 LF AND CONSTRUCT END WALL 12810 PER FOOT PLANS INDEX 430-030 rx , 128 W i H I M PROPOSED PAD I I M I FFE = 131.00 f I ! 1A t 1C Q 1B I I ' 129.51 W 40 i ( 128.,.. 8.50 y I € I ' W -4 I t ME ME o t I REFER TO SHEET C-13.0, 13.1, AND IPROPOSED. PAD i I 1213.2 FOR OFF -SITE ROAD t t FFE = 129.00 9 N I N ! IMPROVEMENT PLANS tt1 I 10 \14 128.50 N I t 2G �i 129.00 129.10 � 5A I I 129.10 �- 129.35JD I ff I Y� I Z t 129.55 / _ 2F - " "' Lu;-128.89 - - - - - ?29` i 129.40 i 128.42 Oi 129.19 128.44 129 129 ------ 1 8.86, 9 128.50 129.00 ' RIDGE 1 i29 `2E 129 -2 I I 129.75 t 12 00 127.91 I 1 I T&7 12 .00 5B j l i � 28.30 TB-6 PROPOSED PAD , 1 E " 128.25 1 D 128.25 2C ^tig FFE = 129.50 129.90 T1W-130 0 t 2B I B1W-124.0 3B TB-1 ! I 2D_____________w_ __� _________W_-____ _____ �_- _ _ _----_---_ 129.50 RIDGE LINE , I I TRANSITION TO 124NL I I 129.0 T1W HEIGHT IML CS TA -130.01 T/W-129.0 __ _____ BNV--124.0 I --- 11s =- - --- I - 11s__ -1 I 129.20 I I 13A _----------- - - - ---2A 1 1------------------ II I I I I I ---------------- I I I II --- 103------------ I I I I I 1 1 R 4C bpi I I! !III PROPOSED STORMWATER POND I I I I 1 30.50 ' /2\ } j I I I TOP OF POND: 130.00 1I I i 1 I s.c a.a I I III 1 BOTTOM OF POND: 109 t NORMAL POOL: 117.50 I I , 8 I I j I I I I I 100 YR/24HR STAGING ELEV: 127.56 I 14A I I 48 PROPOSED PAD I I I I ___1I11 -4 FFE =130.00 1os --- �111 1 1 1 `� t, . V I I ---------------_ I _ _ t i TRANSITION TO _ - - - - _ - - ---- - - - J _ - 129.0TNHEIGHT--- REFER TO SHEET C-13.0, 13.1, AND T/W129.0 ---_ - 115-- ------- - - �.W_ 13.2 FOR OFF -SITE ROAD ^ IMPROVEMENT PLANSBAN-124.0 /1377,80 1 �■rl��� %�_I�IrI■■■r»E� � � ■ � i i �.� ir�Ill�l� _ �►��� a.� CREW C-11 129.0 129.50 � 1'*�37.17- 128.0 135.8 0 134.72 134.65 135.27 136.43 PRETTY POND RD 110+00 1.11+00 112+00 113+00 114+00-► i ***CAUTION*** 811: UTILITY LOCATOR SERVICE 3 t)A`rS BEFORE DtGMNG CALL. ILTOLL FREE 1-{800) 432-4770 OR 811 11 A ONE CALL SYSTEM FOR COMtWNLTY AND JOB SAFETY. ... ... THE ONDUtGROM UTEFTES SNOMN HAVE EM LOCATED FROM FIELD 90.fY WOfpt IM AM OnTM DRAYIINOS. TIE %0tVVMft "ES NO QJARANXE. THAT THE WWEROROU D MUTIES SHOMN COMPRISE ALL SUCH UIUM 1N 1HE AREA 01NM IN SOMM OR ASANDORM tiff SUtEVE.YOR MY EA DM3 NOT WARRANT THAT THE Iw7trEROROLRJO UIUM 900 ARE N THE E%ACT LOCAIM INMATFD. AL"" HE ODES C}RTiY IKAT TNCY ARE LOCATFA AS ACdMIMY AS P09a8LE FROM 6WORHANON AVAUJAStE. THE SUR\£YOR HAS NOT PIHYSICATJ.Y LOCATED THE MWERGROUND UTMJTES. SEASONAL HIGH-WATER TABLE: BASED ON THE GEOTECHNICAL EXPLORATION REPORT BY ANDREYEV ENGINEERING, INC., DATED JULY 10, 2019, THE ESTIMATED SHWT IS GREATER THAN 8.0' BELOW EXISTING GRADE. VERTICAL DATUM CONVERSION PLANS ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD1988). THE CONVERSION FROM THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD1988) TO THE NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD1929) IS: ELEVATION IN NAVD88 PLUS 0.89 FEET_ 3' SHOULDER TO HAVE 2.0%D MAX CROSS �`� REF. TO SHEET C-8.0 FOR SLOPE IN ALL PLACES, REFER TO TYP. PRETTY POND ROAD DETAIL THIS PAGE SECTIONS 115+00 », STORM DRAIN STRUCTURE TABLE STR. TYPE RIM/THROAT ELEV 1A MITERED END SECTION 118.50 18 MANHOLE 129.00 1 C MANHOLE 128.40 1 D MANHOLE 128.75 1 E MANHOLE 130.50 1 F FDOT TYPE C INLET 125.70 CS-1 FDOT TYPE C INLET 128,00 2A MITERED END SECTION 114.00 2B FDOT TYPE C INLET 128.25 2C FDOT TYPE C INLET 128.00 2D FDOT TYPE V INLET 127.95 2E FDOT TYPE C INLET 128.42 2F FDOT TYPE C INLET 128A2 2G FDOT TYPE C INLET 128.50 2H FDOT TYPE C INLET 127.50 21 FDOT TYPE C INLET 129.00 2J FDOT TYPE C INLET 128.00 2K FDOT TYPE C INLET 128.50 2L FDOT TYPE C INLET 128.44 3A MITERED END SECTION 114.00 3B FDOT TYPE C INLET 128.25 4A MITERED END SECTION 114.00 4B MANHOLE 130.50 4C FDOT TYPE C INLET 129.20 5A MITERED END SECTION 124.00 56 MITERED ENQ SECTION 126.50 STORMDRAIN SCHEDULE STRUCTURES SIZE LENGTH TYPE SLOPE IE DOWN IE UP 1AT01B 18" 60' RCP 0.16% 118.50 118.60 1B TO 1C 18" 284' CPP 0.20%D 118.70 119.34 1 C TO 1 D 18" 250' CPP 0.20%D 119A4 119.94 1 D TO 1 E 15" 198, CPP 0.20%D 120.04 120.45 1 E TO 1 F 15" 198, CPP 0.20% 120.55 120.95 1 D TO CS-1 15" 19 CPP 5.00% 120.55 121.50 2A TO 2B 36' 55' RCP 7.27%D 114.00 118.00 28 TO 2C 36" 53' CPP 0.57% 120.00 120.30 2C TO 2D 30" 30' CPP 0.20% 122,15 122.21 2D TO 2E 30" 55' CPP 0.20%p 122.31 122.42 2E TO 2F 30" 28' CPP 0.20% 122.52 122.58 2F TO 2G 30" 51' CPP 0,20%D 122.68 122.79 2G TO 2H 30" 160' CPP 0.20%D 122.89 123.21 2H TO 21 24" 51, CPP 0.20%D 123.31 123.42 2E TO 2K 18" 170' CPP 0.50% 122.52 123.37 2K TO 2L 18" 33' CPP 0.50% 123A7 123.64 2J TO 2H 24" 78' CPP 0.50% 123.31 123.70 3A TO 3B 18" 65' CPP 9.23%O 114.00 120.00 4A TO 4B 18" 109, CPP 6-00% 114.0 120.54 4B TO 4C 18" 117' CPP 0.50%O 123.92 124.50 5A TO 5B 18" 102' RCP 2.45%g 1 124.00 126-50 Issued: Date: A ISSUED FOR PERMITS 01/15/21 P CITY OF ZEPHYRHILLS RESUB 05/14/21 Di I Revisions- Date: 1 SWFWMD RESUBMITTAL 103117/211 '�p FDOT RESUBMITTAL 04/22/21 0 N I 0 40 80 120 SCALE: 1" = 40' Scott K. Stannard, P.E FL P.E. No. 50565 SEAL This item has been digitally signed and sealed by Scott K. Stannard, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified can any electronic copies. Site Engineering - Landscape Architects Commercial Site Solutions, Inc. C.O.A NO. 27575 21764 State Road 54 Lutz, FL 33549 (813) 885-2032 www.css-eng.com WLN ZEPHYRHILLS, LLC 371� NOR"l�}-iSiDF:. PKWY NW BUILDING 4W, SUITE 515 ATLANTA, GA 30327 PH: (404) 27,9 4364 C'ONTAcr: KEVIN FRA7IER Client Name: MULTI -USE COMMERCIAL PRETTY POND RD US HIG11WAY 301 AT PRETTY POND ZEPF-IYRHILL,S, rL Pl is 404-754-6934 C'ONTAC'T: MR. PI-itl,I.iP MORRISSEY 1 Project Name & Location: MV07011M PLAN Drawing Name: Date: 11 /11 /20 Revised: XXX Drawn. SKS Checked: SKS Drawing No. C-6,0 Issued: Date: A ISSUED FOR PERMITS 01/15/21 P CITY OF ZEPHYRHILLS RESUB 05/14/211 11'PROPOSED R/W DEDICATION R/W LINE 36'R/W PROPOSED R/W VARIES 6.0'UNPAVEDSHOULDER SOD LINE SOD IF - 3,0' PAVED SHOULDER 1 2.0' 1 15 EX. 4'MEDIAN _ EX. 11' LANE 3:1 MAX 7�� 1 0.06 .0.02 002 ().02 im MAX - - - - - - -- - - - - - - - - - - - - - ----------- L TYPE B STABILZATION CONCRETE 4-11 MAX LBR 40 SIDEWALK EX, PAVEMENT TO REMAIN TYP. SECTION STA. 112+25.00 TO STA. 114+50.00 N.T.S. 148.0 144.0 140.0 136-0 132.0 128.0 148.0 144.0 140-0 136-0 132.0 128.0 PROPOSED 1 1.0'R/W EX. 36'R/W 3.0'PAVED E.X.4' MEDIAN SHOULDER 2.0'GRASS G 1-5' VARIES SHOULDER L --- -- 0-02 --... 621 0.06 3:1 MA) SLOPE --- ----- I ------------------ ----------- 0.01 ------------------ -------- --- Ei. PAVEMENT T- IY PE B STABILIZATION TO REMAIN LBR 40 PROPOSED 5'SI EWALK 6'STABILIZED SOD I 2-0% MAX CROS 3 SLOPE SHOULDER 4:1 MA)k SLOPE 0+00 0+10 0+20 0+30 0+40 0+50 0+60 PRETTY POND RD. STA 114+00 SCALE: VERT. 1"=2' HORZ. 1"=10' EX, 36* R/W 3.9 PAVED 9:Y A' hA1=r)1AK1 Z>rIL)ULULK CA. LANE 11.0' PROPOSED I 1.0'R[W VARIES EX. LANE 11-5'. 6.0- 5.0' 2.0'GRASS SHOULDER `:1 tml RAAN SLOPE 0.02 0.0 . 0.()6 --------------- I L --------------- 0.01 ------------- I ------ ------------- EPAVEMENT j TYPE B STABILIZATION TO REMAIN LBR 40 PROPOSED 5'SIDEWALK 6STABILIZED SOD 2.0% MAX CROSS SLOPE SHOULDER 4:1 MA* SLOPE 0+00 0+10 0+20 0+30 0+40 0+50 0+60 PRETTY POND RD. STA 113+00 SCALE: VERT. I"=2' HORZ. 1"=10' EX. CHEVRON STRIPING 148.0 EX. LANE VARIES 144.0 140.0 136.0 132.0 128.0 PROPOSED I 1.0'R[W 3.0'PAVED SHOULDER VARIES SHOULDER EX. LANE 13.0*- 6.0-1 5.0' 0.02 ------- r).06 3:1 MA > SLOPE ----------------------------------- ---- 0.01 7 --------- -------------------- PAVEMENT ITYPE 8 STABILIZATION - PROPOSED 5' MEWALK TO REMAIN LBR 40 1 2.0% MAX CROSS SLOPE 6'STABILIZED SOD I SHOULDER 4:1 MA f SLOPE 0+00 0+10 0+20 0+30 0+40 0+50 0+60 PRETTY POND RD. STA 112+00 SCALE: VERT. I"=2' HORZ. I"=10' CENTERLINE PRETTY POND ROAD 148.0 144.0 140.0 136-0 132.0 128.0 EX. LANE VARIES EX. LANE 13.0' 0.02 1 0.02 ----------- ------- ----------- ---------------- J PAVEMENT To REMAIN PROPOSED DRIVEWAY J EX. RNV LINE PROPOSED R/W LINE 11-01 PROPOSED CROSSWALK 7.0' 10% MAX CROSS SLOPE 0+60 FDOT FRICTION COURSE FC-12.5 ­g j-, "it" --if tn A v (TRAFFIC C) (1.5 OPTIONAL BASE GROUP 9 STABILIZED SUBGRADE, MINIMUM LBR OF 40 AND COMPACTED TO 95% MODIFIED NOTE: 18" MIN. FREE PROCTOR MAX. DRY DENSITY DRAINING SUBGRADE VALUE. MUST EXIST BELOW BASE COURSE H.Q. DUTY PAVEMENT SECTION FOR USE OFF -SITE USE (N.T.S.) FDOT SUPERPAVE SP-9.5 OR SP-12.5 ASPHALTIC CONCRETE 00 LIMEROCK BASE COURSE W1 MIN. LBR OF 100 COMPACTED TO 98% MODIFIED PROCTOR MAX. DRY DENSITY, STABILIZED SUBGRADE, MINIMUM LBR OF 40 AND COMPACTED TO 95% MODIFIED NOTE: 18" MIN. FREE PROCTOR MAX. DRY DENSITY DRAINING SUBGRADE VALUE. MUST EXIST BELOW BASE COURSE H.Q. DUTY PAVEMENT SECTION FOR USE ON SITE (N.T.S.) _NQM: ON -SITE ASPHALT PAVEMENT DESIGN BASED ON GEOTECHNICAL EXPLORATION AND EVALUATION BY ANTICUS ENGINEERING LLC, DATED MARCH 21, 2018 Revisions., Date: 1 SWFWMD RESUBMITTAL 03117121 9 FDOT RESUBMITTAL 04/22/211 N Scoff K. Stannard, P.E FL P.E. No. 50565 SEAL This item has been digitally signed and sealed by Scott K- Stannard, P.E. on the date adjacent to the seat. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies, Site Engineering - Landscape Architects Commercial Site Solutions, Inc- C.O.A NO. 27575 21764 State Road 54 Lutz, FL 33549 (813) 885-2032 www.css-eng.com WLN ZEPHYRH I LLS, LLC 3715 NORTHSIDE PKWY NW BUILDING 400, SUITE 515 ATLANTA, GA 30127 PH: (404) 228-4364 CONTACT: KEVIN FRAZIER Client Name: MULTI -USE COMMERCIAL PRETTY POND RD US HIGHWAY 301 AT PRE'rry POND ZEPHYRIJILLS, Ff. PH: 404-754-0914 ('ONTAC'T: MR. PHILLIP MORRISSE'y Project Name & Location: PRETTY POND ROAD GRADING & SECTIONS Drawing Name: Date: 11/11/20 Drawing No. C-8.1 Revised: Xxx Drawn: SKS Checked.- SKS NOTE: CITY OF ZEPHYRHILLS UTILITIES OPERATIONS PERSONNEL AND THE CITY OF ZEPHYRHILLS UTILITIES INSPECTOR SHALL BE NOTIFIED 48 HOURS PRIOR TO THE PROPOSED WATER AND SEWER CONNECTIONS. I f f f IOTE: NO SMALLER THAN 12 GAUGE (SOLID) TRACER WIRE TO C1 COMMERCIAL (WALMART SUPER CENTER) ,E USED FOR LOCATING PURPOSES. CONTINUITY TESTING ON HE TRACER WIRE WILL BE REQUIRED. 1 t. TOTE: CITY WILL PROVIDE WATER METER AND BFP EXCLUDING IRE BFP WHEN IMPACT FEES HAVE BEEN PAID ***CAUTION*** 811: UTILITY LOCATOR SERMCE 3 DAYS BEFORE DIGGING GALL TOLL FREE 1-(800) 432-4770 OR 811 A ONE CALL SYSTEM FOR EOMMIkB7Y AND JOB SAFETY. -- (JUDO__ ..- THE DHMOROLM 1J7IUDES 9KANN HAVE BEEN LOCATED nWM FIELD MWY WORNATN3N AND E711STIM DRAWINGS, THE SURVEYOR MAKES NO OIARANTEE THAT THE Ui6040O NNO UTILITIES SHOWN CN71PftlSE ALL SIK7N LNiRT.ES IN THE AREA. EITHER N S@RV7CE NIR AWHNDOHEO. THE SURVF. HTGTHIER DOES NOT WARRANT THAT THE UNDEItOROUND UMJM SHOWN ARE N NE EXACT LOCATION N DILATED. ALTHOUGH HE DOES CEF IIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSS4LE FROM WDRMATION ALATJ10ti THE STIR7EYLIR HAS NOT PHYSICALLY LOCATED THE UNDERfiRovHgN U7VIFES. WON ..-----......_.----_-.._-----..--_---`-- -_,.. ----_........_.,...°.,--s._.--_---- -_- _-- -_.._ 1 t t t { 1 1 1 t f 8" STUB -OUT CAPPED PROPOSED PAD 1 t 3/4" CHLORINATION SAMPLING POINT FFE = 128.50 t 1 1 2" SERVICE TAP 1 (2) 8"x2" SERVICE TAP 1 t CROSSING #1 & #2 2" SERVICE LINE PROPOSED 8" WATER j 1 t MAIN RELOCATION 1 1 SEWER STUB OUT (RE: SHEET C-13.2) 26 LF OF 6" SEWER f WITH C.O. 1 i STUB OUT LE. = 122.0 1 I.E.=122.0 st 1 I w 1 t SEWER @ 1.0% 1 t { { i { 1 ( PROPOSED PAD SEWER MH 5 x t FFE - 131.00 RIM EL.=129.0 I CROSSING #3 t O t I.E. IN (W) = 121.74 U t 1 I.E. IN (E) = 121.75 I 1 m i ILE- OUT (S) = 121,64 PROPOSED 6" FHA LLI - 1 t ASSEMBLY. (AMERICAN LU I 8"X6" TEE & GATE 1 t VALVE f { 1 I PROPOSED 8" PVC 1 � I 236 LF OF 8" PVC f WATERMAIN PROPOSED PAD t t SEWER @0.5% I CROSSING #4 FFE = 128,50 1! i10' UTILITY 40 LF OF 6" SEWER @ 1.0% ! { EASEMENT f MIN. SLOPE f { I UE SHOWN FOR REF. { STUB OUT CONTRACTOR TO COORDINATE SEWER MH 4 to I I.E. = 121.50 WITH POWER COMPANY FOR TIE-IN RIM EL.=129.25 AND TRANSFORMER LOCATION j I.E. IN (N) = 120.46 ; 8"X8" TEE f OUT (S) = 120.36 (3) 8" GATE VALVES PROPOSED 2" 25' OF 8" PVC I PROPOSED 8" PVC SERVICE LINE 1 f NOTE: 314" METER & BACKFLOW @ 0.50% WATERMAIN t I PREVENTER TO BE INSTALLED BY THE iII­UF:::: CITY OF ZEPHYRHILLS TO SERVICE ' SEWER MH3 THE LIFT STATION. CONTRACTOR TOco { RIM EL.=129.30 CROSSING #9 8"X2" SERVICE TAP I COORDINATE WITH CITY. I.E. IN (NE)=120.23 I.E. OUT (S)=120.13 I t t SEWER MH 1 I RIM EL.=128.9 { CROSSING - I.E. III 119-10(S) 20 LF OF 6" PVC 10' UTILITY i t I.E. IN=122.30(E)- SEWER @ 1.0% SLOPE EASEMENT t I.E. OUT= 119.0(W) ss SEWER STUB OUT 7_ t PROPOSED 2" WITH C.O. t I.E.= 122.5 PROPOSED PAD SERVICE LINE + j f � CROSSING #5 FFE = 129.50 -� t -"- 8"X8" WET TAPPING t 314" WATER SERVICE LINE TO BE BROUGHT rn CROSSING #6 SLEEVE & VALVE { � 314" CHLORINATIONINJECTION � t TO LIFT STATOIN FOR 1/2"METER AND BFP ` 142 LF OF 8" PVC POINT No rArrrNG ASSEMBLY I SEWER @ 2,50% ' 30 LF OF 8" PVC LL 1 SEWER @ 0.5% f t DUPLEX LIFT STATION (TO BE DEDICATED TO THE CITY) 400 LF OF 4" NO P AR CROSSING #7 { 6' BLACK PVC COATED CHAIN LINKED PVC DR 25 FM 1 FENCE WITH DOUBLE GATES TO BE {, CROSSING #8 f I PLACED TO ALLOW ACCESS. 12' WIDE CONCRETE SERVICE DRIVE 8"X2°' SERVICE 2" SERVICE LINE Ij I TO CONNECT TO MAIN DRIVEWAY TAP 1 t RIM EL. = 129.80 SEWER STUB OUT j I.E. IN= 118.85(E) WITH C.O. PROPOSED PAD I.E. IN=119.00(N) I.E. = 125.0 FFE = 130.00 t SEWER MH 2 1 i RIM EL=133.05 { { I.E. IN= 124.78 LE. OUT= 122.65 22 LF OF 6" PVC { { SEWER @ 1.0 /n { t 4" 45° BEND 4" 45° BEND { { I� PROPOSED 8" PVC ! WATERMAIN { { { ---_-.--....,.. �- { 10' UTILITY { EASEMENT _ -- -- -- FM CONTRACTOR TO OPEN CUT ROAD FOR CONNECTION i PRETTY POND RD CORE BORE INTO EXISTING MANHOLE 4" PLUG VALVE 8"X6" TEE & GATE VALVE FORCE MAIN TYING INTO MANHOLE CONTRACTOR TO APPLY SPECTRA SHALL ENTER THE MANHOLE A VERTICAL SHIELD LINING SYSTEM OR DISTANCE OF NOT MORE THAN 2' APPROVED EQUAL ABOVE THE FLOW LINE OF THE RECEIVING MANHOLE PROPOSED 6" FHA ASSEMBLY. - (AMERICAN --_DARLING B-84-13_FHA.) PORTION OF PRETTY POND ROAD TO BE OPEN CUT. 34 LF OF 16" STEEL CASING TO BE ADDED FOR THE PORTION OF 8" WATER MAIN. 12"X8" WET TAPPING SLEEVE & VALVE 3/4" CHLORINATION POINT ! 1 I I I l rill"' l I " f I " C I " I I I I 1 I �- s-'-- "f- - I ' I I I l , 1 l I I I I I I l f I I I I I I I I 1 I ! l I f r' t I (� I I i t 1 l I I I E f I I I I 1 I I I 1 I l TIE-IN INVERT TO BE FIELD VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR TO UTILIZE 8" 45 BENDS DEEMED NECESSARY BY ENGINEER. 1 � I l 1 l I I I 1 I I t 1 I I I I I I I I UTILITY NOTES 1. ALL SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE STATE OF FLORIDA AND THE CITY OF ZEPHYRHILLS. 2. WATER LINES SHALL BE INSTALLED WITH A MINIMUM OF 36" OF COVER UNLESS OTHERWISE NOTED. ALL WATER CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF ZEPHYRHILLS. 3- VALVES SHALL BE RESILIENT SEAT GATE VALVES, DIRECT BURY WITH A VALVE BOX (AWWA C509), 4. 6" WATER LIVE ON -SITE SHALL BE C900 RATED PVC. ALL SERVICE LINES LESS THAN 3" IN DIAMETER SHALL BE PE. 5. SEWER LINES (INCLUDING LATERALS) SHALL BE POLYVINYL CHLORIDE (PVC) SDR 26 PER ASTM D-3034_ 6. SEWER CLEANOUTS SHALL BE IN ACCORDANCE WITH THE THE CITY OF ZEPHYRHILLS DETAILS AND SPECIFICATIONS. 7. THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT UTILITY EXIT POINTS, EXIT PORCHES, ETC. 8. INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS AND FIELD LOCATIONS WHEN POSSIBLE, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION BY DIGGING TEST PITS BY HAND AT ALL UTILITY CROSSINGS WELL IN ADVANCE OF TRENCHING. IF CLEARANCES ARE LESS THAN SPECIFIED ON THE PLAN OR 12". WHICHEVER IS LESS, CONTACT THE DESIGN ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 9. ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO ANNOUNCED BUILDING POSSESSION AND/OR FINAL CONNECTION OF SERVICES. 10. A MINIMUM OF 10 FEET HORIZONTAL SEPARATION MUST BE MAINTAINED BETWEEN WATER AND SEWER LINE'S. THE VERTICAL SEPARATION IS TO BE A MINIMUM OF 18". 11. REFER TO THE PHOTOMETRIC AND ARCHITECTURAL PLANS FOR SITE LIGHTING ELECTRICAL DESIGN AND LAYOUT. 12. ALL SITEWORK SHALL MEET OR EXCEED THE THE CITY OF ZEPHYRHILLS AND ALDI STORES INC_ STANDARDS AND THE SITEWORK SPECIFICATIONS. 13. CONTRACTOR TO PROVIDE ALL TRENCHING, BACKFILLING, & INSTALL ALL ELECTRICAL CONDUITS TO UTILITY COMPANY SPECIFICATIONS. 14_ LOCATION OF SITE UTILITIES SHALL BE VERIFIED BY GENERAL CONTRACTOR & THE PROPER UTILITY COMPANY PROVIDING SERVICE. 15. GENERAL CONTRACTOR SHALL PROVIDE 2' x 2' x 6" THICK CONCRETE APRON AT ALL CLEANOUTS OUTSIDE OF BUILDING. 16. GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL TAP AND TIE ON FEES REQUIRED, AS WELL AS COST OF UNDERGROUND SERVICE CONNECTIONS TO THE BUILDING. 17. ELECTRICAL SERVICE TO PAD MOUNTED TRANSFORMER SHALL BE RUN UNDERGROUND, FROM ROAD RIGHT-OF-WAY TO BUILDING. ASSOCIATED MATERIALS AND COST BY GENERAL CONTRACTOR. 18. ALL ELECTRIC AND TELEPHONE EXTENSIONS INCLUDING SERVICE LINE SHALL BE CONSTRUCTED TO THE APPROPRIATE UTILITY COMPANY SPECIFICATIONS. ALL UTILITY DISCONNECTIONS SHALL BE COORDINATED WITH THE DESIGNATED UTILITY COMPANIES. 19. RESTRAINED JOINTS SHALL BE PROVIDED AT ALL BENDS, TEES, AND FIRE HYDRANTS. 20, DIMENSIONS SHOWN ARE TO CENTERLINE OF PIPE OR FITTING. 21. ALL TRENCHING, PIPE LAYING, AND BACKFILLING SHALL BE IN ACCORDANCE WITH FEDERAL OSHA REGULATIONS. 22. GENERAL CONTRACTOR SHALL HAVE APPROVAL OF ALL GOVERNING AGENCIES HAVING JURISDICTION OVER THIS SYSTEM PRIOR TO INSTALLATION. AGENCY AND UTILITY CONTACTS CITY PLANNING DEPARTMENT` CITY BUILDING DEPARTMENT 5335 8th STREET 5335 8th STREET ZEPHYRHILLS, FL 33542 ZEPHYRHILLS, FL 33542 PHONE: (813) 780-0006 PHONE: (813) 780-0020 CONTACT: TODD VANDE BERG, DIR. CONTACT: BILL BURGESS EMAIL: EMAIL: CITY UTILITIES DEPARTMENT: CITY FIRE DEPARTMENT: 39825 ALSTON AVENUE FIRE STATION No. 1 :ZEPHYRHILLS, FL 33542 6907 DAIRY ROAD CONTACT: JOHN BOSTIC ZEPHYRHILLS, FL 33542 PHONE: (813) 780-0029 CONTACT: DANIEL SPILLMAN EMAIL: PHONE: (813) 780-0041 EMAIL: GAS: POWER: TECO PEOPLES GAS 2501 25TH ST N 1400 CHANNELSIDE DR ST PETERSBURG, FL 33713 TAMPA, FL 33605 CONTACT: MEGAN VONSTETINA CONTACT: JACK EVERIDGE PHONE: (717) 893-9394 PHONE: (813) 309-5966 EMAIL: EMAIL: CAUTION NOTE: CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN AREAS OF BURIED UTILITIES AND SHALL PROVIDE AT LEAST 48 HOURS NOTICE TO THE UTILITY COMPANIES PRIOR TO CONSTRUCTION. CALL SUNSHINE 811 PRIOR TO PERFORMING ANY EXCAVATION TO ARRANGE FIELD LOCATION SERVICES. NOTE: CONTRACTOR SHALL OBTAIN COPY OF ANY EASEMENT DOCUMENTS OR OTHER ENCROACHMENT PERMITS PRIOR TO BEGINNING ANY WORK OFF -SITE OF THE PROJECT AREA, FIRE NOTES: • WATER SUPPLY AND FIRE HYDRANTS SHALL COMPLY WITH NFPA-1, CHAPTER 18.3. • FIRE FLOW FOR BUILDINGS SHALL COMPLY WITH NFPA-1, CHAPTER 18.4, TABLE 18.4.5-2.1. Issued: Date: A ISSUED FOR PERMITS 01/15/21 R 1 CITY OF ZEPHYRHILLS RESUB 05/14/21 D Revisions: Date: 1 SWFWMD RESUBMITTAL 03/17/21 o FDOT RESUBMITTAL 04/22/21 In N 3 0 40 80 120 SCALE: 1" = 40' Scott K. Stannard, P,E. FL P.E. No. 50565 SEAL This item has been digitally signed and sealed by Scott K. Stannard, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. C:: S Site Engineering - Landscape Architects Commercial Site Solutions, Inc.. C.O.A NO. 27575 21764 State Road 54 Lutz, FL 33549 (813) 885-2032 www.css-eng.com WLN ZEPHYRHILLS, LLC 3715 NOR'111SIDE PKWY NW BUILDING 400, StJI`I`E 515 A'I-L.AN'I'A, CAA 10327 P 11: (404) 228-4364 CONTACT: K VIN FRAZIFIZ Client Name MULTI -USE COMMERCIAL LIS HIC.;H 'AY ,01 AT PRE 17Y POND ZEPIIYRHII._LS, E:l_ P1 is 404-754-6914 CON'FAC'1': MR. PHIL_.1_I1? MORRISSI Y Project Name & Location: 81"I"FILITY PLAN Drawing Name: Date: 11 /11 /20 Revised: XXX Drawing No. Drawn: SKS I C-1 1■ 0 Checked: SKS m 0 U 0 U z PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL HYRHILLS, FLORIDA SHEET INDEX PAGE DESCRIPTION W1 TITLE PAGE/KEY PLAN W2-W3 GENERAL NOTES W4-W9 WALL ELEVATIONS W10-W16 TYPICAL DETAILS &CROSS SECTION No 6104 A= STATE OF ,� , `®o ANCHOR WALL ENGINEERING, LLC ` 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNET MN FLOR DA 043 f J/J`• ' / � j j���l��`� O HONE:(9 2) 933-8855 5996 CERT. REGISTRATION: 1 . OF AUTHORIZATION 27077 I ,J ii 1E !E424 30.0 1? 0 TRANSITION TO 29.0 T&N HEIGHT IR 2 6.0 8 D I 1 1 Scale: NOT TO SCALE Proj. No: AF 21-022 Date: 6/2/21 II 3A -- ----- ----FS:-2A - III�-z-®----=-- - I l i l l l l l PROPOSED STORMWATER POND i l l l l l TOP OF POND' 130.00 BOTTOM OF POND: 109 i I I I I I I I E NORMAL POOL: 117.50 l I l4A I I I I I I I 100 YR/24HR STAGING ELEV 127.56 I I I I I - -- - — - - - ----"_1IIIII TRANSITION TO_- --T`3�fi2-4, l 129.0 TAN HEIGHT- -----— BY1/V=124 I � _ a KEY PLAN (N.T.S) 0 PROPOSED SEGMENTAL RETAINING WALL I I MULTI -USE COMMERCIAL VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE ZEPHYRHILLS, FLORIDA SCALE ACCORDINGLY. OLDCASTLE COASTAL Reviewed By: DJA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TITLE PAGE/ KEY PLAN Drawn By: MAH TAMPA, FL Sheet of W1 16 MATERIAL NOTES BASE COURSE NOTES 1. Concrete Retaining Wall Units: "Anchor Diamond Pro Retaining Wall Units" as manufactured by Oldcastle Coastal 1. Place base materials to the depths and widths shown on the Drawings, upon undisturbed soils, or foundation soils prepared as directed under license from Anchor Wall Systems. by the project geotechnical engineer. 2. Geosynthetic Reinforcement: Miragrid 3XT, as shown on the Drawings. a. Extend the leveling pad laterally at least 6 inches in front and behind the lowermost concrete retaining wall unit. 3. Leveling Pad Base b. Provide aggregate base compacted to 6 inches thick (minimum). a. Aggregate Base: Crushed stone or granular fill meeting the following gradation as determined in accordance with C. Wrap toe of wall, including leveling pad, with filter fabric. ASTM D448: 2. Compact aggregate base material to provide a level, hard surface on which to place the first course of units. Sieve Size Percent Passing 3. Prepare base materials to ensure complete contact with retaining wall units. Gaps are not allowed. 1 Inch 100 No. 4 35 to 70 No. 40 10 to 35 ERECTION NOTES No. 200 3 to 10 1. Excavation support, if required, is the responsibility of the Contractor, including the stability of the excavation and its influence on b. Base Thickness: 6 inches (minimum compacted thickness). adjacent properties and structures. 4. Drainage Aggregate: Clean crushed stone or granular fill meeting the following gradation as determined in 2. General: Erect units in accordance with manufacturer's instructions and recommendations, and as specified herein. accordance with ASTM D448. 3. Place first course of concrete wall units on the prepared base material. Check units for level and alignment. Maintain the same Sieve Size Percent Passing elevation at the top of each unit within each section of the base course. 1 Inch 100 4. Ensure that foundation units are in full contact with the leveling pad. 3/4 Inch 75 to 100 5. Place concrete wall units side -by -side for full length of wall alignment. Alignment may be done by using a string line measured from the No. 4 0 to 60 back of the block. Gaps are not allowed between the foundation concrete wall units. No. 40 0 to 50 6. Place 12 inches (minimum) of drainage aggregate between, and directly behind the concrete wall units. Fill voids in retaining wall units No. 200 0 to 5 with drainage aggregate. Wrap drainage aggregate with filter fabric. Provide a drainage zone behind the wall units to within 9 inches of 5. Reinforced Fill: Soil free of organics and debris and consisting of either GP, GW, SP, SW, or SP-SM type, classified the final grade. Cap the reinforced zone and drainage aggregate zone with 12 inches of impervious material. in accordance with ASTM D2487 and the USCS classification system and meeting the following gradation: 7. Install drainage pipe at the lowest elevation possible, to maintain gravity flow of water to outside of the reinforced zone. Slope the main Sieve Size Percent Passing collection drainage pipe, located just behind the concrete retaining wall units, 1 percent (minimum) to provide gravity flow to the 1 Inch 100 daylighted areas. Daylight the main collection drainage pipe to an appropriate location away from the wall system at each low point or 3/4 Inch 70 to 100 at 50 foot (maximum) intervals along the wall. No. 4 30 to 100 8. Remove excess fill from top of units and install next course. Ensure drainage aggregate and backfill are compacted before installation No. 40 15 to 100 of next course. No. 100 0 to 65 9. Check each course for level and alignment. Adjust units as necessary with reinforcement shims to maintain level, alignment, and No. 200 0 to 12 setback prior to proceeding with each additional course. a. PI<6. 10. Install each succeeding course. Backfill as each course is completed. Pull the units forward until the locating surface of the unit b. Unsuitable soils are organic soils and those soils classified as SM, SC, CL, CH, OH, MH, ML, OL, or PT. contacts the locating surface of the units in the preceding course. Interlock wall segments that meet at corners by overlapping 6. Impervious Material: Clayey soil (permeability of less than 10-6 cm/sec) or other barrier which will prevent percolation successive courses. Attach concrete retaining wall units at exterior corners with adhesive specified. into the reinforced soil zone of the retaining wall. 11. Install geosynthetic reinforcement in accordance with geosynthetic manufacturer's recommendations and the shop drawings. 7. Drainage Pipe: Perforated or slotted PVC or corrugated HDPE pipe manufactured in accordance with D3034 and/or a. Orient geosynthetic reinforcement with the highest strength axis perpendicular to the wall face. ASTM F405. The pipe may be covered with a geotextile filter fabric to function as a filter. b. Prior to geosynthetic reinforcement placement, place the backfill and compact to the elevation of the top of the wall units at the 8. Construction Adhesive: Exterior grade adhesive as recommended by the retaining wall manufacturer. elevation of the geosynthetic reinforcement. 9. Filter Fabric: Mirafi Type 140N or equal. c. Place geosynthetic reinforcement at the elevations and to the lengths shown on the Drawings. FOUNDATION SOIL NOTES d. Lay geosynthetic reinforcement horizontally on top of the concrete retaining wall units and the compacted backfill soils. Place the geosynthetic reinforcement within one inch of the face of the concrete retaining wall units. Place the next course of concrete 1. Excavate foundation soil as required for footing or base dimension shown on the Drawings, or as directed by the retaining wall units on top of the geosynthetic reinforcement. Project geotechnical engineer. e. The geosynthetic reinforcement shall be in tension and free from wrinkles prior to placement of the backfill soils. Pull geosynthetic 2. The Owner shall retain the services of a geotechnical engineer to examine foundation soil to ensure that the actual reinforcement hand -taut and secure in place with staples, stakes, or by hand -tensioning until the geosynthetic reinforcement is foundation soil strength meets or exceeds that indicated on the Drawings. Unsuitable soils are defined as any soil covered by 6 inches of loose fill. that does not have sufficient bearing capacity or will cause excessive wall settlement. Remove soil not meeting the f. The geosynthetic reinforcements shall be continuous throughout their embedment lengths. Splices in the geosynthetic required strength. Oversize resulting space sufficiently from the front of the block to the back of the reinforcement, reinforcement strength direction are not allowed. and backfill with suitable compacted backfill soils. g. Do not operate tracked construction equipment directly on the geosynthetic reinforcement. At least 6 inches of compacted backfill 3. The Owner shall retain the services of a geotechnical engineer to determine if the foundation soils will require special soil is required prior to operation of tracked vehicles over the geosynthetic reinforcement. Keep turning of tracked construction treatment or correction to control total and differential settlement. equipment to a minimum. 4. Fill over -excavated areas with suitable compacted backfill, as recommended by the Project geotechnical engineer. h. Rubber -tired equipment may pass over the geosynthetic reinforcement at speeds of less than 5 miles per hour. Turning of rubber -tired equipment is not allowed on geosynthetic reinforcement. 11110///, G UyCk` /." �'0 �v0 61®4 ' _`.11 - `YI scale: RETAINING WALL 1 ?QC= � I d 0 1 PROPOSED SEGMENTAL RE V= NOT TO VERIFY THAT THE BARABIOVE MULTI USE COMMERCIAL STATE O '® SCALE IS 1". IF NOT, ADJUST THE ZEPHYRHILLS, FLORIDA Ae•.a ,� r ��® ANCHOR WALL ENGINEERING, LLC scALEACcoRDwGLY. OLDCASTLE COASTAL TAM PA, FL ®RIO ��� 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK GENERAL Sheet of �`\ MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 Proj. No: AF 21-022 Reviewed By: D,JA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): NOTES sI I I I I I%% PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Date: 6/2/21 Drawn By: MAH SHEET 1 Syr 2 0 0 x U z Q BACKFILL PLACEMENT NOTES SITE DRAINAGE NOTE 1. Place reinforced backfill, spread and compact in a manner that will minimize slack in the reinforcement. 1. This design does not account for any hydrostatic forces on the retaining wall system. It is imperative the finished site grading diverts 2. Place fill within the reinforced zone and compact in lifts not exceeding 6 to 8 inches (loose thickness) where hand -operated water away from the block facing and the reinforced soil zone of the retaining wall system. All buildings located above retaining compaction equipment is used, and not exceeding 12 inches (loose thickness) where heavy, self propelled compaction walls must implement gutter systems with downspouts that direct water through solid PVC pipe to the site storm sewer system or to equipment is used. a location below and away from the wall. Building sump pumps should also direct water away from the wall in the same manner. a. Only lightweight hand -operated compaction equipment is allowed within 4 feet of the back of the retaining wall units. If Concentrated discharge of water above the retaining wall and the reinforced soil zone is not allowed. unable to achieve minimum compaction requirements replace the reinforced soil in this zone with drainage aggregate material. UTILITY NOTES 3. Minimum Compaction Requirements for Fill Placed in the Reinforced Zone: 1. Utility information has been provided to Anchor Wall Engineering for the preparation of these plans. a. Compact to 98 percent of the soil's standard Proctor maximum dry density (ASTM D698) for the entire wall height. 2. Utilities must be properly designed (by others) to withstand all forces from the segmental retaining wall units, reinforced soil mass, b. Compaction requirements for fill placed behind the reinforced soil zone shall be specified by the Project Geotechnical and surcharge loads (if any). Engineer but at no time should be less than 95% of the standard Proctor density (ASTM D698). 3. Storm drains are prone to leaking. Therefore, if a joint in a storm drain is located within 100 feet behind the retaining wall the storm C. Increase compaction requirements for retaining walls with slope heights at the back of the reinforced soil zone greater water pipe must be water tight. Neoprene O-rings must be installed at all storm pipe joints as a minimum. than 5 feet above the top of wall. Verify compaction requirements with the Project geotechnical engineer. 4. Water lines, including irrigation systems, must be water tight within 100 feet behind the retaining wall. Leakage behind a retaining d. Utility Trench Backfill: Compact utility trench backfill in or below the reinforced soil zone to 98 percent of the soil's wall will increase the horizontal pressure against the wall leading to wall failure. For this reason, subsurface waterlines and standard Proctor maximum dry density (ASTM D698), or as recommended by the Project geotechnical engineer. irrigation systems should not be installed above the reinforced zones of the retaining wall, or within 5 feet of the reinforced zone. e. Moisture Content: Within 2 percentage points of the optimum moisture content for all wall heights. f. These notes may be changed based on recommendations by the Project geotechnical engineer. GENERAL NOTES 4. At the end of each day's operation, slope the last level of compacted backfill away from the interior (concealed) face of the 1. The owner or owner's representative has not provided foundation or retained soil strength parameters for design of the segmental wall to direct surface water runoff away from the wall face. retaining wall. In preparation of wall design, soil strength parameters for the foundation and retained soils were assumed by a. The General Contractor is responsible for ensuring that the finished site drainage is directed away from the retaining Anchor Wall Engineering. It is the responsibility of the owner or owner's representative to verify the assumed soil strength wall system. parameters are representative of the soils available for wall construction. If the soil strength parameters are found to be b. In addition, the General Contractor is responsible for ensuring that surface water runoff from adjacent construction inconsistent with those assumed by Anchor Wall Engineering, this design is no longer valid and it is the responsibility of the areas is not allowed to enter the retaining wall area of the construction site. owner or owner's representative to notify Anchor Wall Engineering so the retaining wall system can be redesigned. Failure to CAP UNIT INSTALLATION NOTES notify Anchor Wall Engineering may result in failure of the retaining wall. 1. Apply adhesive to the top surface of the unit below and place the cap unit into desired position. 2. Assumed Design Soil Parameters: a. Reinforced soil: phi = 30 degrees gamma = 115 pcf. 2. Cut cap units as necessary to obtain the proper fit. b. Retained soil: phi = 30 degrees gamma = 115 pcf. 3. Backfill and compact to top of cap unit. C. Foundation soil: phi = 30 degrees gamma = 115 pcf. WALL CONSTRUCTION TOLERANCE NOTES 3. Any excavation below the wall should have proper 1:1 lateral oversizing. Excavation oversizing should be measured from the 1. Wall Construction Tolerances: front of the gravel leveling pad and the back of the lowest reinforcement layer. Refer to detail 2 on sheet W11. a. Vertical Alignment: Plus or minus 1-1/4 inches over any 10-foot distance, with a maximum differential of 3 inches over 4. Wall stationing shown on sheets W4 through W9 is not related to any other stationing shown on the civil plans. Station 0+00 is the length of the wall. on the left end of the wall as seen from the front of the wall. b. Horizontal Location Control from Grading Plan: 5. This set of segmental retaining wall plans are based on the grading plans prepared by Commercial Site Solutions, Inc., dated b.1. Straight Lines: Plus or minus 1-1/4 inches over any 10-foot distance, with a maximum differential of 3 inches over May 14, 2021. If other plans are produced that contain different information than that referenced, this plan may need to be revised and/or the wall may need to be redesigned. the length of the wall. 6. This set of segmental retaining wall plans are based specifically on the wall being constructed with Anchor Diamond Pro block c. Immediate Post Construction Wall Batter: Within 2 degrees of the design batter of the concrete retaining wall units. and Mirafi Miragrid 3XT reinforcement products. Absolutely no substitutions allowed. d. Maximum Differential Settlement: 1:100. 7. Location of the segmental retaining wall in relation to property lines, utility easements, watershed easements, or any other type of FIELD QUALITY CONTROL NOTES easements are the responsibility of the owner or the site civil engineer. Anchor Wall Engineering assumes no liability for the 1. Installer is responsible for quality control of installation of system components. Owner to employ a qualified independent location of the segmental retaining wall, or if construction of the proposed segmental retaining wall encroaches any property lines third party to verify the correct installation of system components in accordance with these specifications and the 8. or easements. It is imperative that the site surveying of the segmental retaining wall be done by the site civil engineer or surveyor and must be Drawings. 2. The Owner, at their expense, will retain a qualified professional to perform quality assurance checks of the installer's work. based on computer generated site/grading plans and not profile plans done by Anchor Wall Engineering. Surveying of the segmental retaining wall must take into account the design batter indicated on the enclosed plans and details. Failure to take into 3. Correct work which does not meet these specifications or the requirements shown on the Drawings at the installer's account wall batter for segmental retaining wall surveying will produce incorrect locations of all top of walls and shall be corrected expense. 4. The Owner or Owner's Representative shall retain the services of a geotechnical engineer to perform compaction testing g at no cost to Anchor Wall Engineering or the segmental retaining wall contractor. Wall geometry, locations, slopes and surcharge loads for the segmental retaining wall were measured from the site plan of the reinforced backfill placed and compacted in the reinforced backfill zone. referenced above, and partially reproduced on sheet W1. If conditions vary in the field from those shown on this plan, Anchor a. Testing Frequency (or as directed by Project Geotechnical Engineer) Wall Engineering must be notified prior to construction of the segmental retaining wall to review the design and/or plans. b. One test for every 2 feet (vertical) of fill placed and compacted, for every 50 lineal feet of retaining wall. Modifications to the design and/or plans may be required after the review, and may take up to ten business days to complete. c. Vary compaction test locations to cover the entire area of the reinforced soil zone, including the area compacted by the 10. This segmental retaining wall has been designed in general accordance with the 2020 Florida Building Code, 7th Edition. hand -operated compaction equipment. 11. If there are discrepancies between any information on these plans and information in the project specifications, the more restrictive information takes precedence. HJJ °-IRMO r NO 61®4 $._f�-`-_ Scale: D 1 PROPOSED SEGMENTAL RETAINING WALL r # =1ltl" MULTI -USE COMMERCIAL NOT TO VERIFY THAT THE BAR ABOVE STATE OF ® SCALE IS1". IF NOT, ADJUST THE ZEPHYRHILLS, FLORIDA ANCHOR WALL ENGINEERING, LLC SCALE ACCORDINGLY. OLDCASTLE COASTAL TAM PA, FL GENERAL Sheet of 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK ���� Proj. No: AF 21-022 Reviewed By: At1W \et MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 p JA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): NOTES W3 16 ,/ I I l t t ` PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Date: 6/2/21 Drawn By: MAH SHEET 2 APPROXIMATE LOCATION OF DROP STRUCTURE AT BACK OF REINFORCED ZONE z (SEE DETAIL 2 ON SHEET W13 IF REQUIRED) Of 129 128 127 126 125 124 123 122 - 121- 120 O O + O TOP OF WALL RAGRID 3XT - 7.1)Qft - - - - - - MIRA RID 3XT - 7.00 ft - - R6GRID3T.OQft — -- -- -- -- -- MIRAG IJ23XT -- RBGRID 3XZ7.0Q — — — — — — — — — — MIRAGRIp 3XT - 7.00 ft — — i Ft6QRID X - .OQft — — — — — — — — — — MIRA RID 3XT - 7.00 ft — — — GRADE BEHIND WALL -131 EL=130.17 130 — — — — — — — — —MIRA RID XL - LO f -129 -128 — — — — — — — — — N1IR6GRID 3XL- LoQ1L__ 127 — — — — — — — — N1F6Q RI D 3XL- L04�L-126 — — — — — — — ——MIRAGRID 3XL- 7.OQX= 125 47A MIRAGRID 3XT - 7.0Qft MIRAGRID 3XT - 7.00 ft - MIRA RID XT - 7.00ft .50 - - - - - - - - - - - - - - - - - - - EL=122_50 -123 —EL=122--'-------------------------------------------------— — _ ------------------------------------ -122 BASE OF WALL FINISHED GRADE AT BASE -121 - -120 Lo O O — L6 o Lo N N o 6 o M Cl) d' 6 � C5 Lo Lo O Co r Lo r- + + O O + + + O O Co + + + O O O + O + O + O + O + O + O t O a Q Q d d Q d a Q a Q Q Q ¢ d fn U) U) U) U) U) U) U) U) to fn to U) fn -- BEGINNING OF WALL TIES APPROXIMATE LOCATION OF 18" PIPE DIAMOND PRO® - ELEVATION VIEW INTO END OF WALL IN BELOW WALL (SEE DETAIL 1 ON SHEET W13) �� / "I \WALL 1 (MAXIMUM APPLIED BEARING PRESSURE = 1,400 PSF) 90-DEGREE INSIDE CORNER W4 (SCALE: 1" - 5'-0") TOP OF WALL GRADE BEHIND WALL -131 EL=130.17 131- 130 EL=1 30.17 129 - MIRAGRID 3XT - 7.04ft — — — — — — — — — — MIRAGRID 3XT - 7.00ft — — — — — — — 128 - MIRAGRID 3XT - 7.04ft MIRAGRID 3XT - 7.00 ft 127- -- -- -- -- — — — — — — — — — 126 - MIRAC RID 3XT - 7.OQft — — — — — — — — — — MIRAGRID 3XT - 7.00 ft — — — — — — — 125 I R6CL 3XT 7.OQ ft — — — — — — — — ID 3 — — MIRA RXT - 7.00 ft — — — — — — — 124 M IRAGRID 3XT - 7.OQft MIRAGRID 3XT - 7.00 ft — 123 — — — — — — — — — — — — — — — — EL=122.50 --------------------------------------------------------------BASE OF _ _ _ _ --- �--- WALL-WAL 6 o 00 6 00 o O 6 O o O L O o 6 o N rn N O O O O O Q Q Q Q d ¢ a a Q Q Q U) to U) U) U) W U) V) V p CU . _M®�® O 6104 j ANCHOR WALL ENGINEERING, LLC OR �r '`•.,,�vat •' �� 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK �gCO1�y. MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 DIAMOND PRO® - ELEVATION VIEW 2 WALL 1 CONTINUED W4 (SCALE: 1" = 5'-0") NOTES: 1) LOCATIONS OF CORNERS SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. 2) LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. Scale: 0 1 1 1 VERIFY THAT THE BAR ABOVE 1 If = 5'-0" IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Proj. No: AF 21-022 Reviewed By: DJA Date: 6/2/21 Drawn By: MAH IJV - - - - Nil RA ID X7-Lojft 129 -128 3XL- 7.OQf_ - - - - -MIRAGRID 127 - - - - -MIRAGRID3XL-L0 f -126 - - - - - MpA RI XL - Loll 125 124 MIRAGRID 3XL - 7.OQf_ - - - - - EL=122.50 FINISHED GRADE AT BASE _-123 122 o L6 o o + + + + + U) to fn U) LEGEND - INDICATES REINFORCEMENT LENGTH eX DETAIL NUMBER AND/OR ELEVATION CHANGE - SHEET NUMBER 1 _ INDICATES APPROXIMATE LOCATION W1 OF INSIDE ANGLED CORNER X - INDICATES LOCATION e WX - INDICATES APPROXIMATE LOCATION OF SECTION CUT W1 OF 90-DEGREE INSIDE CORNER PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA DLDCASTLE COASTAL REVISION DATES (SEE SHEET Wt FOR REVISION HISTORY): TA PA, FL Sheet of WALL ELEVATIONS W4 16 4 r Z ul 2 W F fA N J J a 3 0 x n z a 2 0 J 0 x U z a 131- TOP OF WALL EL=130.17 GRADE BEHIND WALL -131 EL=130.17 130 129 CIF 6GRID 3XT - 7.0Qft - - _ _ - - MIRAGRIDjXI - 7.00 ft - - _ _ - - �QIRA alD 3XT - 7.OQft- _ _ - - -WAGRID 3XT- TOUL_ 130 129 �aIF3eGRID 3XT 7.04ft MIRAGRID XI - 7,00 ft �Q1RAGRID XLZ OQft- - Q XL- LOO fl` 12$ - - - - - - - - - - - - IN11R 127 126 -__MIRvA_GRID 3XT - 7.0Qf - - - - - - MIRAGRIDJU - 7.00 ft - - - - - - MIRAGRID 3XT - 7.OD ft- - - - - - NIIRAGRID 3XL- 7 OQIL-- 126 125 - MIRAG -BID 3XT - 7.OQft _ _ _ _ - - MIRAGRIQj) T - 7.00 ft - - _ - - - MIRAGRID 3XT 7.OQft- - - - I _ _ MIRA RID XT - 7.OQ 125 124 124 MIRAGRID 3XT 7.OQft MIRAGRID�XT - 7.00 ft I _ I MIRAGRID 3XT - 7.OQft- IVIIRAGRID 3XT_- 7.0 f 123 122- _-----------------------------------------t'=---�------ _ _ _ _ _ - _ - - - - - _ _ _ - -I- -------------------- - - - - - _ - � - EL=122.50 ---- _ -122 123 APPROXIMATE LOCATION OF 15" PIPE ��'`--%" APPROXIMATE LOCATION OF DROP I 121- BASE OF WALL THROUGH/BELOW WALL (SEE DETAIL 1 ON SHEET W14) STRUCTURE AT BACK OF REINFORCED ZONE -121 120- FINISHED GRADE AT BASE (SEE DETAIL 2 ON SHEET W13 IF REQUIRED) I -120 119- APPROXIMATE LOCATION OF CS-1 CONTROL STRUCTURE -119 IN FRONT OF WALL (SEE DETAIL 1 ON SHEET W14) 118- -118 O rn LO LO o CD 6 (D o 6 o LO o t` r- 00 00 0) �n o �n o 0) O C) r L6o r 6 N N t + r r + r t r t + t + + r r r r r t t t t r N N N + N + t N N a Q Q Q Q Q a Q a Q Q Q Q Q Q a fn (n fn U) U) U U U) U) U) U DIAMOND PRO® - ELEVATION VIEW APPROXIMATE LOCATION OF 18" PIPE WALL 1 (CONTINUED) BELOW WALL (SEE DETAIL 1 ON SHEET W13) V (SCALE: 1" = 5'-0") 131- EL=130.17 W 130 129- MIRAGRID 3XT - 7.04ft - - - - - - MIRAGRIDT - 7.00 ft - - 128 - MIRAGRID 3XT - 7.0Qft MIRAGRID�XT - 7.00 ft 127- -- - - -- -- - 126 - MIRAGRID 3XT - 7.01ft - - - - - - MIRAGRIDT - 7.00 ft - - - 125- -17A MIRAGRID 3XT - 7.0jf - - - - - - MIRA RIDJXT - 7.00 ft - - - TOP OF WALL --\ r-- GRADE BEHIND WALL 131 i EL=130.17 130 - - MIRAGRID 3XT - 7.09 ft- - - - - - MIRA ID XT - LouL� 129 -128 - - MIRAGRID 3XT - 7.0Qft- - - - - - WRA JD XT - 7.OQ� 127 - - MIRAGRID 3XT _ 7.0Qft- - - - - -MIRA ID XT - LO Qlf -126 - - MIRAGRID 3XT 7.09 ft- - - - - - MIRA RID XT - 7.0 f `125 !')A 123-- MIRAGRID 3XT - 7.OQft - - - - _ - MIRAGRIDXT - 7.00 ft - - - - - MIRAGRID 3XT - 7.0Qft- - - - - - MI RID XT - 7.OQ�_ -123 122- EL_122.50 - - - - - - - - - - - - - - - - --- --- - - - - - - - - - - - - - - - - - - - - - - _ - - - - - - - - - - - - - - - - - - - - - BASE OF WALL �T _ _________________ FINISHED GRADE AT BASE _ EL=122.50 -122 (o N o co 6 cM o L6 o L6 LO LO (p o rn C.0 o 00 L6 o 00 00 U-) o 0) O t N + N + N t N + N t t N N t N t + t N N N + N t t N N t t N M Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q U) U) U) U) U) U) U) U) U) U U) U U) U) ,l�tliilf�®®7� 5104 o f % STATE OF ANCHOR WALL ENGINEERING LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK FLORIDA REGISTRATION: 61043 MINNETONKA, MN 55345-5996 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 DIAMOND PRO® - ELEVATION VIEW 2 WALL 1 CONTINUED W5 (SCALE: 1" = 5'-0") NOTES: 1) LOCATIONS OF CORNERS SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. 2) LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL Scale: 1 „ = 51-011 Proj. No: AF 21-022 Date: 6/2/21 0 1 I VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: I DJA Drawn By: I MAH LEGEND - INDICATES REINFORCEMENT LENGTH eX - DETAIL NUMBER AND/OR ELEVATION CHANGE - SHEET NUMBER 1 _ INDICATES APPROXIMATE LOCATION W1 OF INSIDE ANGLED CORNER X - INDICATES LOCATION W INDICATES APPROXIMATE LOCATION OF SECTION CUT OF 90-DEGREE INSIDE CORNER PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TA PA, FL Sheet of WALL ELEVATIONS W5 1 16 4 p i 2 0 J J D! O 2 z z Q GRADE BEHIND WALL TOP OF WALL 134 EL=13350 133 — 132 J M1�23) - 10.00 ft 131 J - 130 �5 R_0_. XT�4�ft— I I 129 L-10_..4o.�L.. _ _— �1BA�RIPXTQft— -- — — , - — — - 128-11 -MIFjAGRID 3X(T - 10_.4QA 127 - -- —.—. -- - — — — — - 10.00 ft MIRAG131pCT -- -- — — 126 ��d�GRI�T - 10�Q0�_ — _M1BA�IPXTI Qft 125 �d�EGRl10.4oit_XT�QQQft — — ID 3XT - 10_,,Qo_ _ — __ _ —__— _ _ .—. -- — _ — — _mJBASHIPX 123 EL=122.50 — — — — — — — — — — — 122 - -- -- _ _ ._ _ — — — — — — _ _-- — — — — — — — — — — — — — — — — — — — — — — — BASE OF WALL ___ ._ — — — — — — — — — — — — — — . FINISHED GRADE BASE- — — — — — — — — — — — — — — — — — — — �n O 00 00 4- o O LO O o LO O O o LO o . N N C) cM t t Cl) M t Cl) t Cl) t t t t t V- t t t Q Q Q Q Q Q Q Q Q Q Q Q F- cn to fn U) fn U) cn cn U) cn to cn C. Huth DIAMOND PRO® - ELEVATION VIEW WALL 1 CONTINUED V26 (SCALE: 1' = 6-0") O 51043 k STATE ZO ANCHOR WALL ENGINEERING, LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Scale: 11 1 = 5'-011 Proj. No: AF 21-022 Date: 6/2/21 I I VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: I DJA Drawn By: I MAH E5 W W Z Z 0 ._ _.134 1-132.83 132.17- 132 1136 — .-MIRAQ_W 3XT - 10.Okft 130 —I MIRAG�Jp wXLQmOQft—_ 129 _ 128 _—_ — MIRAGRID 3XTi-=127 — _.— — MIRAG—W _ -3XTi- 10 OQft -_.126 __ _ MIRAGFUP 3XT - 10.OQft 7125 124 _ MIRAGRID 3XT'- 10.OQft_ — — - EL=122.50 -123 =122 C) LO+ _ -__ LO + co 07 U) SEE SHEET W7 FOR LEGEND AND NOTES. PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS. FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TAMPA, FL Sheet I of WALL ELEVATIONS I W6 1 16 TOP OF WALL GRADE BEHIND WALL W 132 EL--13t.5-0- t r F -132 131 I-EL=1-30.83 ---- -- -- 131 _j 130 fL E-L=110-tT- 130 L A 129ft IRAGRID 3X IQ Q_ 3XT 'r-129 t 12871 _M W F;U�-Q 0 L 4- 4 t A�� I �L .00 -kF :L ft 3x -1-60 A I L-128 z 127- -127 126 -Lam;;A(a MikAbR6 3XT-10j0ft MIRA 126 125-10.QQf-L -J- _L_ 09I QA7-- -T- F- —7- MIMdfk_1�3kz__ U.- f-7,00 ft 125 124 oft 1 MI �APELQ3ILL- 10� I [P-3.A -10 _m _QSjQ_MT_ -90 ft I 1 i _IVI06�AL_U 7.00 124 ft 123-1 EL=122.50 _ _ 1._ _ _ ___ 122 -7- I — — — — L — — — — — j — — — — — I- L — — — — — — L - — — — — — - j — — — — — — - L — — — — — — EL=122.50 123 6ASE-0F WALI-�- FINISHED -GRADE A-T-BASE­ - ­1 -1 __ --- - ___ -L --- - - - -- -- --- - -1 -- -- - -- ---- --- 4 IL-122 C) LO o A - LO C) LO 0 u') C) C) LO C) u') LO LO CD C.0 ti r- 00 00 0) 0) O C) C14 CN to LO u') LO LO U) W U) U) U) U) DIAMOND PRO® - ELEVATION VIEW , WALL I(CONTINUED) WV (SCALE: 1" = 5'-0") TOP OF WALL W - _j GRADE BEHIND WALL 131 --- mz 131 r EL--13017 _r r 130 130 -T- 129 -M -IR-A Q- -1D -3X-T- --7.- 0-ji 0 L L ]�128 128-4-- L - L b�QEJQ 3XI - 7 QQ_ft___ 127- MIBAQ D_MT-7.Qpft M1R6GQIL_ : 12X -32 127 126 -4ERAGO 4- M1qAGR -ISUL7-126 12,54 - - - Gip - - - - - - - t -- - ----r------ t - - - - - - - - - -L 125 RKGA I& 3X_ 124 124 T F ------- T- --r------ ----- L 90ft 123-1 EL=1 22.50 L -- - - - - - - - - - - L - - - - - ___L�=1L2..0 'IF-123 122 -4" ------F1M1SH­E[�GRADE AT-B4E- L - - 122 -4 ! u') C) C14 M M C) u') C) u') ur) u') C) V) Cp co C> r U') r- C) 00 V) 00 C1 0) ur) C) 0) Co 0 U-) u') ur) U3 to u) U) to to u') u') to LO U) CO 15 (0 (0 (0 Cn 0) Cf) co 0) C. Hu No 6104 M, 0.. STATE OF zo �0 �r7 �Y' ANCHOR WALL ENGINEERING, LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 DIAMOND PRO® - ELEVATION VIEW 2WALL 1 (CONTINUED) F ,J (SCALE: 1" = 5'-0") NOTES: 1) LOCATIONS OF CORNERS SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. 2) LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL Scale: 111 = 51-011 Proj- No: AF 21-022 Date: 6/2/21 0 VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: I DJA Drawn By: I MAH LEGEND INDICATES REINFORCEMENT LENGTH AND/OR ELEVATION CHANGE DETAIL NUMBER SHEET NUMBER INDICATES APPROXIMATE LOCATION OF INSIDE ANGLED CORNER INDICATES LOCATION 3INDICATES APPROXIMATE LOCATION OF SECTION CUT OF 90-DEGREE INSIDE CORNER PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TAMPA, FL I Sheet I of WALL ELEVATIONS I W7 1 16 4 C. 30 MIL PVC LINER REQUIRED BEHIND REINFORCED ZONE - TOP OF WALL GRADE BEHIND WALL 130 - - EL=12950 — — ; - — — — - - -- - -- - - - ; _ - - .._ _ __ _._ _.. - - — — -- -- r - - - -- - -- - - - - - - - - - - €t= r2s:5o -130 129 I - 129 I I � i - — 128 _ L _ -- _ __ ___ 1 L_ — — _-- I - _ - -- - _ _-_ _ L _. -- _ L _ _ J _ _ __. L- — — _ _. _1 _. _- _ z _ _ .. �— — ..._ __ _ - _ _ __. _ _ _ r 128 i�GS�i-- 0.- IfG_- ! 3 L_7_ 0 12267 1274 126 9 .7_. _ '• -M_ - -- -a --- �---- 7 T - _ft.: -I -- - - -- J-L-_O_ jIX2. . t 1�3XT T 121254 5MIR�G 124 12 124 RB�ZQft �16_G �1�QT - 7.0J0 - r aj EL=25 EL 122.50 I 122� - L123 T1 i----- - RADE-ATB�SE 122ffNFSHED o LO O C) o r LO r o N LO N o C7 - LO - o Ch LO It CD LO o LO C0 LO o LO C.0 ti (0 C0 C0 C0 CO CO (O CO CO CO C0 (0 C0 (0 C0 CO d d a a Q d a d Q a Q d Q a ¢ Q 1 J TOP OF WALL 130-�- - Za-Et=�.56----------- 129 1 MIKA_ 128 4-- �- - - L - - L�"G Q�L- 7.D-Qft 127 - L. -__- - - --�� 126 MIRAG ID 3�Qjft 125 ,�111-lR-LG-- 1 124 123 I 1 122 - - - —EL=122.50 _ _ _ - r-- --BASE AFF/ALL- - 00 00 + C0 co (0 (D U) in 0%J 1111111/1 ® �, �GEN No 6104 jju STATE OF /1f10i11 \i DIAMOND PROD - ELEVATION VIEW 1 WALL 1 (CONTINUED) W8 (SCALE: 1" = 6-0") 30 MIL PVC LINER REQUIRED BEHIND REINFORCED ZONE GRADE BEHIND WALL o f --71 ------r------ ------ I — _ zz — F -- -T ------ i -- — — —— ;— — — — f -- — -- ------ _ ;--- - --- — ---- - - —W ----- - ----- 130 -- EL tz950 --L - T. ou IL- - --- --.. _� - 1 - - l - I - - - - - 1 - - i -L_ -�z&QBID3XL-7.0 MIIRAGRID3XL-7.0 129 .._.. J i - -- - - ------ _- I - ----....�---- I MfL MI 1D3XT-7. --- RID 3XT - 7T_ - -_ - - .- - —f— -_ I -� - - - - I - - 128 MIRAGXT - 7.0 126 - - -- - - -- - --i--------- - --I-- - - fi------ I ID _--i— ---i --- L1253XT7.0 - ---- - - - - 124 -- -_-- ----- 1----T I------ i --- ----_-_--- �_ r_'-- � �— - MA IF-f-7 S. EL-122.50 I-123 — ----I ----- - - - FINISHD GRADE AT 6�45E- - - ---- - -- —I - - -- - - ----- _ -� - ----- ------ L ----- J------1 ----- - - - -] �122 _- - - - - - - - - - o Cn C0 to C0 o r uO r o N u') N o CM LO cM o d LO o 'gf' u') + + + + + t + t t t t t H H F- I- H H H H H (n Cn U) (n W U) (n co W U) DIAMOND PRO" - ELEVATION VIEW 1 2 WALL 1 CONTINUED 116 W8 (SCALE: 1" = 6-0") LEGEND - INDICATES REINFORCEMENT LENGTH NOTES: AND/OR ELEVATION CHANGE 1) LOCATIONS OF CORNERS SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO - DETAIL NUMBER WX - SHEET NUMBER ! I \ _ INDICATES APPROXIMATE LOCATION CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. W1 OF INSIDE ANGLED CORNER 2) LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO X - INDICATES LOCATION 3 WX OF SECTION CUT W1 - INDICATES APPROXIMATE LOCATION j OF 90-DEGREE INSIDE CORNER } CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. Scale: 0 1 PROPOSED SEGMENTAL RETAINING WALL I I MULTI -USE COMMERCIAL 111 ERITHAT THE BAR = 5'-011 V ZEPHYRHILLS, FLORIDA ANCHOR WALL ENGINEERING LLC S 1". FANOT,DJJUSTTBHOEE SCALE ACCORDINGLY. OLDCASTLE COASTAL TAM PA, FL 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK Proj. No: AF 21-022 Reviewed By: D,j/{ REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): Sheet of MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 WALL ELEVATIONS W8 16 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Date: 6/2/21 Drawn By: MAH � � TOPOFVW4L G BEHIND 13D� 13O 12B 120 128-L _ '- -- l 128 ���g�I -�o�L_�__ 127 ---- ---'-- --- ���_ ---~~���~~--�~ -~-- �l ----- -----' _�-- �---'-- � L'1��� 1�7 ----' 126 OALft— | 126 125 �- 125 134 123 - --- - --- --- - 124 123 122-� - �� -' -� - - |' - - �� - - �] ���� ��� ��� - - - /- '- -� -� - - L�� - -� -- - _ _] -� _� _ -' _� L ' -' -- -� _ L- _ -' _ _ ' ��J _ _ _ _ _ E�}F\KA4L _ _ 'L_'FfN E}Bf��OE - _ _ _ L- _ -' _ -' - -/ -- -' '- - - - ']-122 C�l - -' - - -- -� - �- L� LO - - C11 co - - - - '- - - -- - - - - - - �-- - - - �� 00 - - - - - ��� '----- - - -' 00 0) - - - - -'- - - - - a) C) - - -- C) - - -05 - - -'- -�-��- -- - - - - '- -- - - C14 04 r^ r- ,^ 1- r- rl- r- nm vv *v *o oo 00 131 13O .29' 128' 127 126 125 124 123 122 DIAMONOPROO-ELEVATONNEN GRADE BEHIND WALL TOP OF WALL 2 ZQ MI AGRIQJ&T-f A����4o��� WALL �����|����U�J�� | h� - ANCHOR - '-- ENGINEERING, '----. _____. ___ s000BAKER ROAD, SUITE so DESIGN ENGINEER: JowC.*u,o* MINwsrpwmA, Mwonn*o-5een FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 BEGINNING OFWALL |N 90-DEGREE INSIDE CORNER -+131 Z 13O 1 T'2B J-12O -L12T � {-128 125 Z 134 -T- 123 NOTES: J-122 1} LOCATIONS OFCORNERS SHOWN ARE APPROXIMATE AND SHOULD BEVERIFIED |NTHE FIELD PRIOR TO �� CONSTRUCTION OFTHE SEGMENTAL RETAINING WALL. 00 - 2}LOCATIONS OFUTILITIES SHOWN ARE APPROXIMATE AND SHOULD BEVERIFIED |NTHE FIELD PRIOR TO m | CONSTRUCTION OFTHE SEGMENTAL RETAINING WALL. » � VERIFY THAT THE BAR ABOVE /or. IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed BY: I DJA LEGEND u~�-����n��� �� ' INDICATES REINFORCEMENT LENGTH ' AND/OR ELEVATION CHANGE ' DETAIL NUMBER SHEET ' - INDICATES APPROXIMATE LOCATION OFINSIDE ANGLED CORNER ' INDICATES LOCATION ' INDICATES APPROXIMATE LOCATION DFSECTION CUT OFAO'DEGREEINSIDE CORNER PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHI[LS. FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET vmFOR REVISION *mronv 12 1 /2" A INSIDE CURVE r 12" C C OUTSIDE CURVE SAW CUT AS REQUIRED TO CONSTRUCT MITERED CORNER TOP SPLIT FACE AND END WALL FACE 1. ALWAYS START CAPPING WALL FROM THE LOWEST ELEVATION. 2. LAYOUT CAPS PRIOR TO USING ADHESIVE. 3. CUT CAPS TO FIT. VARIOUS COMBINATIONS OF LONG AND SHORT CAP FACES WILL BE NECESSARY FOR RADII GREATER THAN THE MINIMUM. 4. ALTERNATE SHORT AND LONG CAP FACES EVERY OTHER CAP TO ACHIEVE A STRAIGHT ROW OF CAPS. 5. USE EXTERIOR -GRADE CONSTRUCTION ADHESIVE TO SECURE CAPS. 6. REFER TO DETAIL 3 ON SHEET W10 FOR ADDITIONAL INFORMATION. DIAMOND PRO® 1 CAP BLOCK DESIGN DETAILS W10 (NOT TO SCALE) No 6104 , # AUz ' STATE OF ANCHOR WALL ENGINEERING, LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 TOP VIEW 812 I PPONT \/IFW 8 I I SIDE VIEW DIAMOND PRO® 2 3-WAY BLOCK VIEWS W10 (NOT TO SCALE) 8" ° 18" 12.5" 8" 18" STRAIGHT UNIT TRFNC PAD G P ,C/ORNER UNIT " 11" 4 12" r 1011 17.25" Y CAP UNIT DIAMOND PRO° 3 ISOMETRIC BLOCK VIEWS W10 (NOT TO SCALE) 6„ MINIMUM COMP GRF`E` N PADSE LE 11" MR Np,TNE SOIL DIAMOND PRO° 4 TYPICAL BASE PREPARATION W10 (NOT TO SCALE) EXTEND GEOSYNTHETIC REINFORCEMENT TO WITHIN 1" OF THE LOWER BLOCK FACE 11" MIN. DIAMOND PRO® 5 REINFORCEMENT CONNECTION DETAIL W10 (NOT TO SCALE) Scale: 0 1 PROPOSED SEGMENTAL RETAINING WALL I I MULTI -USE COMMERCIAL AS SHOWN VERIFY FNOT ADJUST ABOVE E ZEPHYRHILLS, FLORIDA SCALE ACCORDINGLY. OLDCASTLE COASTAL Proj. No: AF 21-022 Reviewed By: DJA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TYPICAL DETAILS Date: 6/2/21 Drawn By: MAH TAMPA, FL Sheet of W10 16 II c De --•'— V IYI1111.. VVIYIr PllJ 1 I—V VI\l11 �1VL/•lf\ BASE LEVELING PAD DIAMOND PROD 1 TYPICAL STEP-UP DETAIL W11 (NOT TO SCALE) FABRICFILTER 7. li • •"k' • r' �I .M12 INCHES OF • 11''i� r*r,t FINISHED V DRAINING AGGREGATE GRADE •a� �.fi _GE• • 6" MINIMUM COMPACTED L GRANULAR BASE ti 7rv// �n•Y�%Y/s�l�/�y CIS: I LEVELING • __ y�l/ V1r/�_ Wos = WIDTH OF OVERSIZING 1 2 -0 De = DEPTH OF EXCAVATION 1 L = LENGTH OF GEOSYNTHETIC REINFORCEMENT Wos = (2 * De) + L + 6" '11m DIAMOND PROD 2 1:1 EXCAVATION OVERSIZING W11 (NOT TO SCALE) ,t`►►iifitfll��! No 6104 .. t slu 01. STATE OF �f%ID?' ANCHOR WALL ENGINEERING LLC ........... 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 ifill I �BII ►► PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Scale: AS SHOWN Prol. No: AF 21-022 Date: 6/2/21 FENCE BY OTHERS - MUST BE INSTALLED DURING WALL CONSTRUCTION SLEEVE AND NON -SHRINK GROUT AROUND POST SLOPE MAY VARY CAP BLOCK j ` >i `%/X`%\`jj� I ,/ DIAMOND PRO BLOCK jPOST MUST PENETRATE TWO I 'LAYERS OF REINFORCEMENT 1 jj (MINIMUM) I 7' /__----------- I I I � � I � I � I L!_ GEOSYNTHETIC REINFORCEMENT j I FILTER FABRIC (TYP) ' 0 1 IVERIFY THAT THE BAR ABOVE IS V. IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: I DJA Drawn By: I MAH SLEEVE AND NON -SHRINK GROUT AROUND POST SLEEVE INSTALLED DURING WALL CONSTRUCTION CAP BLOCK DIAMOND PRO BLOCK DIAMOND PROD 3 FENCE BEHIND WALL IF REQUIRED W11 (NOT TO SCALE) PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA JLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TAMPA, FL Sheet I of TYPICAL DETAILS I W11 1 16 i 2 0 U J 0 2 0 Z Q FACE VIEW CAP BLOCK DIAMOND PRO BLOCK CS-1 CONTROL STRUCTURE (BY OTHERS) 7° CK UNITS PIPE DIAMOND PRO° CONTROLSTRU (NOT TO SCALE) " "� No 104 ! $ � � Scale: •• ,TA N� AS SHOWN ANCHOR WALL ENGINEERING LLC ,re �� .. 0�,� �- 6� 4\ 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 Proj. No AF 21-022 Date: 6/2/21 0%0 I PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 y vw FILTER FABRIC (TYP)!�\\ \\ 7/7 xAA �A , \ �A 4/ //\/�/ 12 INCHES OF FREE DRAINING AGGREGATE jAA/VAVAjAAj A /V/ V/,x / / GEOSYNTHETIC REINFORCEMENT I I L_ J �X \, WRAP PIPE IN FILTER 15" PIPE BELOWITHROUGH FABRIC TO REDUCE FINES WALL FACE (BY OTHERS) WASHING OUT THE FACE SECTION VIEW W1 PIPE EXTENDING THROUGH WALL VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: DJA Drawn By: MAH PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA DLDCASTLE COASTAL TAMPA,FL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): Sheet of TYPICAL DETAILS W14 16 r r z 5 N� C. HU No 6104 _u 1 OF .•'?® ANCHOR WALL ENGINEERING, LLC t®R`Ot' \� ,�jl4`goie�` 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 i + PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Scale: AS SHOWN Proj. No: AF 21-022 Date: 6/2f21 DIAMOND PROD 1 WALL 1 STA 4+35 W15 (NOT TO SCALE) 0 1 VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: I DJA Drawn By: I MAH t10'-0" PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TAM R Sheet of CROSS SECTION I W15 1 16 z'F r yl NOTE: IF FENCE IS REQUIRED BEHIND WALL, SEE DETAIL 3 ON SHEET W11. 2 W8 NWL EL. = 117.50 1 4 � C HUYe�' No 6104*� * !Uj STATE OF ANCHOR WALL ENGINEERING, LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK FLORIDA MINNET MN � ��,�`ee` PHONE: 2 933-8 55 58� CERT. OF AUTHORIZATION: 127077 tt1 ( ) 1 W1 Q MIRAGRID 3XT - TRIM AT PVC LINER [ 1 / 6" MIN COVER 100 YR/24 HR = 127.56 7° 6'-0" FINISHED GRADE IJ Scale: AS SHOWN Proj.No: AF21-022 Date: 6/2/21 4 6„ 4 J10 2,_0„ W1 DIVERSION DITCH (3:1 MAX SLOPE, 2 FT DEPTH) �L MIRAGRID 3XT. 7.Q FT \ 30 MIL PVC LINER 12 INCHES OF FREE �\��i DRAINING AGGREGATE MIRAGRID 3XT. 7.0 FT j/j�f/j�/j MIRAFI TYPE 140N FILTEff FABRIC (TYP) MIRAGRID 3XT. 7.Q FTj DIAMOND PROD 1 WALL 1 a STA 6+90 W1 (NOT TO SCALE) 0 1 VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed BY: DJA Drawn By: MAH ►SED SEGMENTAL RETAININ MULTI -USE COMMERCIAL ZEPHYRHILLS. FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): L TAMPh, FL Sheet 0' CROSS SECTION W16 16 4 I PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL HYRHILLS, FLORIDA SHEET INDEX PAGE DESCRIPTION W1 TITLE PAGE/KEY PLAN W2-W3 GENERALNOTES W4-W9 WALL ELEVATIONS W10-W16 TYPICAL DETAILS & CROSS SECTION FE \-, d` 1 No 6STATE OF ANCHOR WALL ENGINEERING, LLC Z®R1�� r°° `°�� !® ° $® ®lil11f 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 }� �4�� PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 r - 1 ,75 f 12 :00 t 78-7 12 .00 } — TB —6 e. :ate, I BEGIN/END WALL 111D s.z 2C T30.o I . 2 3B TB-1 TRANSITION TO 24 2159 8= J 29.0 TAN HEIGHT � 24. ' y — r 2A I _ �_ _ -z __- �:i iI --- — ` - -�.Tj 1 PROPOSED STORMWATER POND I t o TOP OF POND 130.00 �.o o + I I BOTTOM OF POND: 109 i �� NORMAL POOL: 117.50 I 3 100 `fR/24HR STAGING ELEV 127 56 B-4 bE v' TRANSITION TO t; 129.0 TN HEIGHT-- . T — 5 _ — — _ « .�- -- -- � _-- 116 ----- — — _— - 24. - ;, _. - 8 124.0 1 _— 120 _ DIVV ' - 124 " t i r r 127 1 {29 32 133 _ (} 13�. v 1 F `— y- ... 131 T/tA 129 = Scale: NOT TO SCALE Prof. No: AF 21_022 Dater 6/2/21 1 1 VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: DJA Drawn By: MAH KEY PLAN (N.T.S) PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS. FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TAMPA, FL TITLE PAGE/ Sheet of KEY PLAN W1 16 M MATERIAL NOTES BASE COURSE NOTES 1. Concrete Retaining Wall Units: "Anchor Diamond Pro Retaining Wall Units" as manufactured by Oldcastle Coastal 1. Place base materials to the depths and widths shown on the Drawings, upon undisturbed soils, or foundation soils prepared as directed under license from Anchor Wall Systems. by the project geotechnical engineer. 2. Geosynthetic Reinforcement: Miragrid 3XT, as shown on the Drawings. a. Extend the leveling pad laterally at least 6 inches in front and behind the lowermost concrete retaining wall unit. 3. Leveling Pad Base b. Provide aggregate base compacted to 6 inches thick (minimum). a. Aggregate Base: Crushed stone or granular fill meeting the following gradation as determined in accordance with C. Wrap toe of wall, including leveling pad, with filter fabric. ASTM D448: 2. Compact aggregate base material to provide a level, hard surface on which to place the first course of units. Sieve Size Percent Passing 3. Prepare base materials to ensure complete contact with retaining wall units. Gaps are not allowed. 1 Inch 100 No. 4 35 to 70 No. 40 10 to 35 ERECTION NOTES No. 200 3 to 10 1. Excavation support, if required, is the responsibility of the Contractor, including the stability of the excavation and its influence on b. Base Thickness: 6 inches (minimum compacted thickness). adjacent properties and structures. 4. Drainage Aggregate: Clean crushed stone or granular fill meeting the following gradation as determined in 2. General: Erect units in accordance with manufacturer's instructions and recommendations, and as specified herein. accordance with ASTM D448. 3. Place first course of concrete wall units on the prepared base material. Check units for level and alignment. Maintain the same Sieve Size Percent Passing elevation at the top of each unit within each section of the base course. 1 Inch 100 4. Ensure that foundation units are in full contact with the leveling pad. 3/4 Inch 75 to 100 5. Place concrete wall units side -by -side for full length of wall alignment. Alignment may be done by using a string line measured from the No. 4 0 to 60 back of the block. Gaps are not allowed between the foundation concrete wall units. No. 40 0 to 50 6. Place 12 inches (minimum) of drainage aggregate between, and directly behind the concrete wall units. Fill voids in retaining wall units No. 200 0 to 5 with drainage aggregate. Wrap drainage aggregate with filter fabric. Provide a drainage zone behind the wall units to within 9 inches of 5. Reinforced Fill: Soil free of organics and debris and consisting of either GP, GW, SP, SW, or SP-SM type, classified the final grade. Cap the reinforced zone and drainage aggregate zone with 12 inches of impervious material. in accordance with ASTM D2487 and the USCS classification system and meeting the following gradation: 7. Install drainage pipe at the lowest elevation possible, to maintain gravity flow of water to outside of the reinforced zone. Slope the main Sieve Size Percent Passing collection drainage pipe, located just behind the concrete retaining wall units, 1 percent (minimum) to provide gravity flow to the 1 Inch 100 daylighted areas. Daylight the main collection drainage pipe to an appropriate location away from the wall system at each low point or 3/4 Inch 70 to 100 at 50 foot (maximum) intervals along the wall. No. 4 30 to 100 8. Remove excess fill from top of units and install next course. Ensure drainage aggregate and backfill are compacted before installation No. 40 15 to 100 of next course. No. 100 0 to 65 9. Check each course for level and alignment. Adjust units as necessary with reinforcement shims to maintain level, alignment, and No. 200 0 to 12 setback prior to proceeding with each additional course. a. PI<6. 10. Install each succeeding course. Backfill as each course is completed. Pull the units forward until the locating surface of the unit b. Unsuitable soils are organic soils and those soils classified as SM, SC, CL, CH, OH, MH, ML, OL, or PT. contacts the locating surface of the units in the preceding course. Interlock wall segments that meet at corners by overlapping 6. Impervious Material: Clayey soil (permeability of less than 10-6 cm/sec) or other barrier which will prevent percolation successive courses. Attach concrete retaining wall units at exterior corners with adhesive specified. into the reinforced soil zone of the retaining wall. 11. Install geosynthetic reinforcement in accordance with geosynthetic manufacturer's recommendations and the shop drawings. 7. Drainage Pipe: Perforated or slotted PVC or corrugated HDPE pipe manufactured in accordance with D3034 and/or a. Orient geosynthetic reinforcement with the highest strength axis perpendicular to the wall face. ASTM F405. The pipe may be covered with a geotextile filter fabric to function as a filter. b. Prior to geosynthetic reinforcement placement, place the backfill and compact to the elevation of the top of the wall units at the 8. Construction Adhesive: Exterior grade adhesive as recommended by the retaining wall manufacturer. elevation of the geosynthetic reinforcement. 9. Filter Fabric: Mirafi Type 140N or equal. c. Place geosynthetic reinforcement at the elevations and to the lengths shown on the Drawings. FOUNDATION SOIL NOTES d. Lay geosynthetic reinforcement horizontally on top of the concrete retaining wall units and the compacted backfill soils. Place the geosynthetic reinforcement within one inch of the face of the concrete retaining wall units. Place the next course of concrete 1. Excavate foundation soil as required for footing or base dimension shown on the Drawings, or as directed by the retaining wall units on top of the geosynthetic reinforcement. Project geotechnical engineer. e. The geosynthetic reinforcement shall be in tension and free from wrinkles prior to placement of the backfill soils. Pull geosynthetic 2. The Owner shall retain the services of a geotechnical engineer to examine foundation soil to ensure that the actual reinforcement hand -taut and secure in place with staples, stakes, or by hand -tensioning until the geosynthetic reinforcement is foundation soil strength meets or exceeds that indicated on the Drawings. Unsuitable soils are defined as any soil covered by 6 inches of loose fill. that does not have sufficient bearing capacity or will cause excessive wall settlement. Remove soil not meeting the f. The geosynthetic reinforcements shall be continuous throughout their embedment lengths. Splices in the geosynthetic required strength. Oversize resulting space sufficiently from the front of the block to the back of the reinforcement, reinforcement strength direction are not allowed. and backfill with suitable compacted backfill soils. g. Do not operate tracked construction equipment directly on the geosynthetic reinforcement. At least 6 inches of compacted backfill 3. The Owner shall retain the services of a geotechnical engineer to determine if the foundation soils will require special soil is required prior to operation of tracked vehicles over the geosynthetic reinforcement. Keep turning of tracked construction treatment or correction to control total and differential settlement. equipment to a minimum. 4. Fill over -excavated areas with suitable compacted backfill, as recommended by the Project geotechnical engineer. h. Rubber -tired equipment may pass over the geosynthetic reinforcement at speeds of less than 5 miles per hour. Turning of rubber -tired equipment is not allowed on geosynthetic reinforcement. % 7 � _ ko A Scale: 0 1 PROPOSED SEGMENTAL RETAINING WALL NOT TO VERIFY THAT THE BAR ABOVE MULTI -USE COMMERCIAL BATE m SCALE IS 1". IF NOT, ADJUST THE ZEPHYRHILLS, FLORIDA ANCHOR WALL ENGINEERING LLC SCALE ACCORDINGLY. OLDCASTLE COASTAL TA PA, FL �° 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK Sheet f �� °'°••.�...,....-„ ° \ Proj. No: AF 21-022 Reviewed By: DJA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): GENERAL o p prp�t@ MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 NOTES 6 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Date: 6/2/21 Drawn By: MAH SHEET 1 r r t 1 -- i 0 0 0 z a BACKFILL PLACEMENT NOTES 1. Place reinforced backfill, spread and compact in a manner that will minimize slack in the reinforcement. 2. Place fill within the reinforced zone and compact in lifts not exceeding 6 to 8 inches (loose thickness) where hand -operated compaction equipment is used, and not exceeding 12 inches (loose thickness) where heavy, self propelled compaction equipment is used. a. Only lightweight hand -operated compaction equipment is allowed within 4 feet of the back of the retaining wall units. If unable to achieve minimum compaction requirements replace the reinforced soil in this zone with drainage aggregate material. 3. Minimum Compaction Requirements for Fill Placed in the Reinforced Zone: a. Compact to 98 percent of the soil's standard Proctor maximum dry density (ASTM D698) for the entire wall height. b. Compaction requirements for fill placed behind the reinforced soil zone shall be specified by the Project Geotechnical Engineer but at no time should be less than 95% of the standard Proctor density (ASTM D698). c. Increase compaction requirements for retaining walls with slope heights at the back of the reinforced soil zone greater than 5 feet above the top of wall. Verify compaction requirements with the Project geotechnical engineer. d. Utility Trench Backfill: Compact utility trench backfill in or below the reinforced soil zone to 98 percent of the soil's standard Proctor maximum dry density (ASTM D698), or as recommended by the Project geotechnical engineer. e. Moisture Content: Within 2 percentage points of the optimum moisture content for all wall heights. f. These notes may be changed based on recommendations by the Project geotechnical engineer. 4. At the end of each day's operation, slope the last level of compacted backfill away from the interior (concealed) face of the wall to direct surface water runoff away from the wall face. a. The General Contractor is responsible for ensuring that the finished site drainage is directed away from the retaining wall system. b. In addition, the General Contractor is responsible for ensuring that surface water runoff from adjacent construction areas is not allowed to enter the retaining wall area of the construction site. CAP UNIT INSTALLATION NOTES 1. Apply adhesive to the top surface of the unit below and place the cap unit into desired position. 2. Cut cap units as necessary to obtain the proper fit. 3. Backfill and compact to top of cap unit. WALL CONSTRUCTION TOLERANCE NOTES SITE DRAINAGE NOTE 1. This design does not account for any hydrostatic forces on the retaining wall system. It is imperative the finished site grading diverts water away from the block facing and the reinforced soil zone of the retaining wall system. All buildings located above retaining walls must implement gutter systems with downspouts that direct water through solid PVC pipe to the site storm sewer system or to a location below and away from the wall. Building sump pumps should also direct water away from the wall in the same manner. Concentrated discharge of water above the retaining wall and the reinforced soil zone is not allowed. UTILITY NOTES 1. Utility information has been provided to Anchor Wall Engineering for the preparation of these plans. 2. Utilities must be properly designed (by others) to withstand all forces from the segmental retaining wall units, reinforced soil mass, and surcharge loads (if any). 3. Storm drains are prone to leaking. Therefore, if a joint in a storm drain is located within 100 feet behind the retaining wall the storm water pipe must be water tight. Neoprene O-rings must be installed at all storm pipe joints as a minimum. 4. Water lines, including irrigation systems, must be water tight within 100 feet behind the retaining wall. Leakage behind a retaining wall will increase the horizontal pressure against the wall leading to wall failure. For this reason, subsurface waterlines and irrigation systems should not be installed above the reinforced zones of the retaining wall, or within 5 feet of the reinforced zone. GENERAL NOTES 1 E 3 1. Wall Construction Tolerances: 4 a. Vertical Alignment: Plus or minus 1-1/4 inches over any 10-foot distance, with a maximum differential of 3 inches over the length of the wall. 5 b. Horizontal Location Control from Grading Plan: b.1. Straight Lines: Plus or minus 1-1/4 inches over any 10-foot distance, with a maximum differential of 3 inches over the length of the wall. 6 c. Immediate Post Construction Wall Batter: Within 2 degrees of the design batter of the concrete retaining wall units. d. Maximum Differential Settlement: 1:100. 7 FIELD QUALITY CONTROL NOTES 1. Installer is responsible for quality control of installation of system components. Owner to employ a qualified independent third party to verify the correct installation of system components in accordance with these specifications and the 8 Drawings. 2. The Owner, at their expense, will retain a qualified professional to perform quality assurance checks of the installer's work. 3. Correct work which does not meet these specifications or the requirements shown on the Drawings at the installer's expense. 4. The Owner or Owner's Representative shall retain the services of a geotechnical engineer to perform compaction testing 9 of the reinforced backfill placed and compacted in the reinforced backfill zone. a. Testing Frequency (or as directed by Project Geotechnical Engineer) b. One test for every 2 feet (vertical) of fill placed and compacted, for every 50 lineal feet of retaining wall. C. Vary compaction test locations to cover the entire area of the reinforced soil zone, including the area compacted by the 10 hand -operated compaction equipment. 11 ANCHOR WALL ENGINEERING LLC ''..,�� ��. 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK F MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 The owner or owner's representative has not provided foundation or retained soil strength parameters for design of the segmental retaining wall. In preparation of wall design, soil strength parameters for the foundation and retained soils were assumed by Anchor Wall Engineering. It is the responsibility of the owner or owner's representative to verify the assumed soil strength parameters are representative of the soils available for wall construction. If the soil strength parameters are found to be inconsistent with those assumed by Anchor Wall Engineering, this design is no longer valid and it is the responsibility of the owner or owner's representative to notify Anchor Wall Engineering so the retaining wall system can be redesigned. Failure to notify Anchor Wall Engineering may result in failure of the retaining wall. Assumed Design Soil Parameters: a. Reinforced soil: phi = 30 degrees gamma = 115 pcf. b. Retained soil: phi = 30 degrees gamma = 115 pcf. C. Foundation soil: phi = 30 degrees gamma = 115 pcf. Any excavation below the wall should have proper 1:1 lateral oversizing. Excavation oversizing should be measured from the front of the gravel leveling pad and the back of the lowest reinforcement layer. Refer to detail 2 on sheet W11. Wall stationing shown on sheets W4 through W9 is not related to any other stationing shown on the civil plans. Station 0+00 is on the left end of the wall as seen from the front of the wall. This set of segmental retaining wall plans are based on the grading plans prepared by Commercial Site Solutions, Inc., dated May 14, 2021. If other plans are produced that contain different information than that referenced, this plan may need to be revised and/or the wall may need to be redesigned. This set of segmental retaining wall plans are based specifically on the wall being constructed with Anchor Diamond Pro block and Mirafi Miragrid 3XT reinforcement products. Absolutely no substitutions allowed. Location of the segmental retaining wall in relation to property lines, utility easements, watershed easements, or any other type of easements are the responsibility of the owner or the site civil engineer. Anchor Wall Engineering assumes no liability for the location of the segmental retaining wall, or if construction of the proposed segmental retaining wall encroaches any property lines or easements. It is imperative that the site surveying of the segmental retaining wall be done by the site civil engineer or surveyor and must be based on computer generated site/grading plans and not profile plans done by Anchor Wall Engineering. Surveying of the segmental retaining wall must take into account the design batter indicated on the enclosed plans and details. Failure to take into account wall batter for segmental retaining wall surveying will produce incorrect locations of all top of walls and shall be corrected at no cost to Anchor Wall Engineering or the segmental retaining wall contractor. Wall geometry, locations, slopes and surcharge loads for the segmental retaining wall were measured from the site plan referenced above, and partially reproduced on sheet W1. If conditions vary in the field from those shown on this plan, Anchor Wall Engineering must be notified prior to construction of the segmental retaining wall to review the design and/or plans. Modifications to the design and/or plans may be required after the review, and may take up to ten business days to complete. This segmental retaining wall has been designed in general accordance with the 2020 Florida Building Code, 7th Edition. If there are discrepancies between any information on these plans and information in the project specifications, the more restrictive information takes precedence. Scale: 0 1 NOT TO VERIFY THAT THE BAR ABOVE SCALE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Proj. No: AF 21-022 Reviewed By: DJA Date: 6/2/21 Drawn By: MAH PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TAM PA, FL GENERAL Sheet of NOTES W3 16 SHEET 2 4 k 4 1P APPROXIMATE LOCATION OF DROP w STRUCTURE AT BACK OF REINFORCED ZONE z (SEE DETAIL 2 ON SHEET W13 IF REQUIRED) TOP OF WALL GRADE BEHIND WALL 0 0 13 U--Et=130.T7 - i- - ___ __. ___ -_ _-- _- ._- --- -- - .. __..___ .— __ ___ __. _ _._ __ __ ___ - .__ ._- __ _...__ _ -- -- -- -- --- ._-- -- .._ __ _-_ __. ___ .- _ .__ __ ..__..-._ _ _.-. _ ..--- -- --- _-- i.._ _-- ..__ ___ ,__ -___ -_ __ i ---- --- --_ _-- -- -- _-- --_ -_- €--1`3(YA7'! 130 i 129 _ - - — -- _ — — IRAG.BID i _ 7 0Q _ — _ _ — . f __- — --._ -- ; — MI8AGRID 3XT - 7.a0 ft .- — —., — . ! —� _ — .— _ _ _ __ _ —_ — _._ __. .—MIRABID __ _ 3XL -_7.00 ft -129 128 - rt - -e. G 14_ - B r; _ -__� - - _ - _ �.. _ -_ _1__ _ ._-- _ __ _ _-_ - _._ _._ __ ._ 13 T i -_ _ _�OlBBSzR:�_X �44._ -_ __ __ - - - _ _ _. __ _. _ _ ._ _ . - _- -_ - _ . - _ — _ - GRID 3X 0 !LIRA L -_ 1 28 127 126 I GBI _a ___- -- - -- -- _.- _ _ — _ _ _ ._ ._ '_ MIRAGRT.. ._ _ . - _-- . - __. . _ _ _ . -. _ _ _ — _ _ N1Jf2AGRID 3XL 127 1 26 125 - -- —_ �. GBI XI _ I- -- — --� _ _—_-- — --- _._ _ r _. _- _ __ __..-- —' — — _ __ .. _� -- -.__ _.._ ._ _ 0. _._. _-- — . MI RID 3XT - 7.00 ft _ — ___ __ _ _ -_ _ - __-. _ _ .., ._ ___ � _.__ _ ._ — __._ _- -- _ — __ _ �.-- .__ _. -—MIRAGRID __ _ _._. - 3XL- 7.00 ft �125 124 .. 124 - MIRAGRID _ X --_ 123 — - i _ .�MIFAGRID3XT-7.tl - MIRA R D XL Z,,OQ ft 123 EL=122.50 ! I EL=122_50? 122 ---j -----� _ L — EINJSHIED_GRADE_AT BASE —— 122 l-- __ __-_BASEDF \A1ALL_ __. _ _..1 _ 121 m 120 __.- -- -- _-._. _... _-- o o _ .-- -- -- LO -- -- -- -- -- __ _- __ __ ..__ o _ __ .__ -._ LO _- __ 4- o --- . - -- _-. LO o L __ _ _ - --- .- -o �__ _ __- __ __ .__ - _ O I_ _ — L __ __ __ ; - _ __ .-- -- _-- -- o LO 120 O O r t t t r t 04 t (V t M + m IT t t t V) t U) + CO + co t r- Il- t t O O O O O O O O O O O O O O O O Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q co (7 U) 07 (7 U) 07 07 BEGINNING OF WALL TIES APPROXIMATE LOCATION OF 18" PIPE DIAMOND PROD - ELEVATION VIEW INTO END OF WALL IN BELOW WALL (SEE DETAIL 1 ON SHEET W13) 1 WALL 1 MAXIMUM APPLIED BEARING PRESSURE = 1,400 PSF 90-DEGREE INSIDE CORNER W4 (SCALE: 1" = 6-0") TOP OF WALL GRADE BEHIND WALL 131 - -- - — - — _ _ _... -- ..-... 131 --------.7 _ __ _I_®_.._ ,.____—____._� __._—____ ____ I.___._ Ee=lse.rr� 130 130 i � _ 129 MIRAGRID 3XT _ 7.OQft—_ i _ — —_ i i E i MIRAGRID3XT - 7.00 ft _ — _— — __ _'..._ I ___ .__- _�— _ € ..__ _ - _ ___ MIRA FBI— XL-.7.OQ� 129 128 I__ -.1- 128 �'LR@_GBID 3XT 7.QQ ft ! I i_---. M_ �RAGFQ 3XT 7 00 tf _�.. - — MIRA RID _ T -_7.0( 127 - �- - - �- - - - -- -- - - —� -_ - -, 127 126 MIRAGRID 3XT - 7.OQft �� - I A RI 3 Tom- - - -- - - - - —;— - . - _ MIRA &ID XT -..LOQ , 126 125� MIRgG,�ID T-7. ft----1-----__ - i-- _ ._-�.__e--� - ! -- MIFAGRID3XT-7 - - -- ----�MIRA -y AD XL-7.0 ft 125 124 MIRAGEID 3Xif _ 7• ft - _� ! I _ - _ T _ - M_ �F�A�RQ3XT - 7�0 ft _ - i T &IRA F�ID XT - 7.0 1124 - - - - 123 -- ----9 --------�—� EL=122 50 -- BASE -OF WAtiz- FINISHED -GRADE AT -BASE __ ! - - ___ _ _.. _ _ � 122 LO o LO o LO o to o LO o LO o LO O LO o I- 00 O t t t W t O t O t Co t r r N t t t N t CM t M t t LO t t O O Co O O r r r r r r r r r r r L7 L•7 � � � (n (i � � � L7 � � V) � � DIAMOND PRO® - ELEVATION VIEW 2 WALL 1 CONTINUED W4 (SCALE: 1" = 6-0") _= No 6104 !!G= -. " STATE �d'+w ANCHOR WALL ENGINEERING, LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 LEGEND NOTES: 1) LOCATIONS OF CORNERS SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO X - WX - DETAIL NUMBER SHEET NUMBER CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. 2) LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE X - INDICATES LOCATION AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO WX OF SECTION CUT CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. Scale: I " = 5'-011 Proj. No: AF 21-022 Date: 6/2/21 0 1 II VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: I DJA Drawn By: I MAH - INDICATES REINFORCEMENT LENGTH AND/OR ELEVATION CHANGE e- INDICATES APPROXIMATE LOCATION W1 OF INSIDE ANGLED CORNER e- INDICATES APPROXIMATE LOCATION W1 OF 90-DEGREE INSIDE CORNER SED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): WALL ELEVATIONS TAMPA, FL Sheet I of W4 1 16 1t z v; i W F N N J J a 3 0 x U z a 2 0 U J 0 2 U z a TOP OF WALL --\ �-- GRADE BEHIND WALL 131- \ I EL=130.17 1 + 1 .3 U 129 __MII�G$ID 3XT 7.OQft- - - - - - - MIRAGBIDXI -7Q0 ft - - - - - --MjF�GRID 3XT ZOQft- - - 128 - �- 127 MIF�GRID 3XT 7.OQft- - - - - - - MIRAGRID XI -JyQQ - - i- - i- --�QjRAGRID 3XT _ Z,OQft- - - 126 -MIR®GEID 3XT 7.01fL - - - - - - MIRAGRID_3XI - 7.00 ft - - - - i - --�IRAGRID 3XT-- 7 01ft- 125 - MIRAGRID 3XT _ 7.OQft - - MIRAGRIDXT - 7.00 ft - - I - I - - MIRAGRID 3XT 7.OQft- - - -131 EL=130.17 yin - MJR9Sz@12axL- LOO fL 129 - i - - �1IjjRAGRID 3XT- LOO ftL 1278 3XL- LOUL-126 IMIRAGRID -I- -MiRA RID 3XT-7.00 125 I- I 124 124 MIRAGRID 3XT - 7.0Qft MIRA RIDjXT - 7.00 ft I I - -- MIRAGRID 3XT - 7.OD ft- I - �VI_IRAGRID 3XT - 7.0 f 123 122- _ - EL_i22.5o -------------------------------------------I--'=,�---�- - - - - - - - - - - - - - - - - ---�-- T1 = -123 EL 122.50 -122 APPROXIMATE LOCATION OF 15" PIPE �`''_��_- I APPROXIMATE LOCATION OF DROP I 121- BASE OF WALL _ - THROUGH/BELOW WALL (SEE DETAIL 1 ON SHEET W14) STRUCTURE AT BACK OF REINFORCED ZONE I -121 120- (SEE DETAIL 2 ON SHEET W13 IF REQUIRED) I -120 119- FINISHED GRADE AT BASE APPROXIMATE LOCATION OF CS-1 CONTROL STRUCTURE -119 IN FRONT OF WALL (SEE DETAIL 1 ON SHEET W14) 118- � -118 o LO 6 o LO CD 6 ro o rn o 6 o t` � 00 00 O rn o rn o O O O r- L o N LO N + + + + t t t + t + t t + N N N t + N N + N Q d Q Q a Q Q d Q d Q a Q a Q Q U) U) U) U) CO U) U) U) (n U) U) U) U) U) U) DIAMOND PRO® - ELEVATION VIEW APPROXIMATE LOCATION OF 18" PIPE 1 WALL 1 CONTINUED BELOW WALL (SEE DETAIL 1 ON SHEET W13) W5 (SCALE: 1" = 5-0") 131- EL=130.17 _ 130 129- MIRAGRID 3XT - 7.0Qft -- -- - - MIRAGRIDJXT - 7.00 ft - - C 128- �I I IR3AG RID 3XT - 7.0Qft MIRAGRID�XT - 7.00 ft 127 - - - - - - 126 SIR -ACRID 3XT - 7.01ft - - - - - - MIRAGRID_3XT - 7.00 ft - - - 125- MIRAGRID 3XT - 7.0Qft - - - - - - MIRA RIDJXT - 7.00 ft - - - 124 123 MIRAGRID 3XT - 7.0Qft - - - - - - - MIRAGRID�XT - 7.00 ft - -- EL=122.50 ----------------------------------- ---------- ----- 122- LO o 6 o L6 o 6 + + + + + + + N N N N N N N U) U) U) U) U) U) U) �v �����ittl6J9,+Jrj d Q 5104 •b '� 4tiy STATE o�`�� ,�}r �Cj ANCHOR WALL ENGINEERING, LLC 3e� ..... 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK FLORIDA REGISTRATION: 61043 j %� MINNETONKA, MN 55345-5996 f I'p. i PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 3' TOP OF WALL GRADE BEHIND WALL Of L-131 w EL=130.17 130 - - MIRAGRID 3XT - 7.OQft- - - - - - MIRAGRID 3XT - - 129 -128 _ - - MIRAGRID 3XT - 7.0Qft- - - - - - MIRA ID XT - 7.OQ- 127 _ - - MIRAGRID 3XT - 7.00- - - - - - MIRAGRID 3XT - 7.0Q_1L_- 126 - - MIRAGRID 3XT 7.01ft- - - - - - MIRAGRID 3XT - 7.OQ 125 17A - - MIRAGRID 3XT - 7.0Qft- -------------------- - BASE OF WALL - o 6 o 6 o 00 N N N N N U) U) U) U) U) DIAMOND PRO® - ELEVATION VIEW 2 WALL 1 CONTINUED W5 (SCALE: 1" = 5-0") NOTES: 1) LOCATIONS OF CORNERS SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL 2) LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL Scale: 0 1 1 1 VERIFY THAT THE BAR ABOVE 1 1] = 5'-0" IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Proj. No: AF 21-022 Reviewed By: DJA Date: 6/2/21 Drawn By: MAH - - - - MIRAGRID 3XT - LO f EL=122.50 _-123 FINISHED GRADE AT BASE 122 6 o L6 o 00 rn rn O N N N M U) U) U) LEGEND e- DETAIL NUMBER WX - SHEET NUMBER X - INDICATES LOCATION WX OF SECTION CUT - INDICATES REINFORCEMENT LENGTH AND/OR ELEVATION CHANGE e- INDICATES APPROXIMATE LOCATION W1 OF INSIDE ANGLED CORNER e- INDICATES APPROXIMATE LOCATION W1 OF 90-DEGREE INSIDE CORNER PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TAMPA, FL Sheet of WALL ELEVATIONS I W5 I 16 V P _ 134J_ ( J T ( - - GRADE BEHIND ALL _ __ TOP OF WALL - r ----- 1 ( -. - -- -- - ! - - - - - - 133� L - -- - - J - -- - L - L -- - -- - - EL=1s . s -- - 132 €L 132r7 — -� — — — — - — -- -- ---- --! --- -----+ ----€L 417- ---- --- M1ASzB1Das- 10'00 ft J �— 131 -- - - - -- - - --�- - - L- - - - .- - - - - - 130I - O�QO_ -. .-� - - -- T - .-. _- _- -t- __ _- __ - ---�— -- - - __ L- ---� - .__ _- .__ -_ _J - - I - -- T �- - __ - -f- � - --T---- I 129fiID3X�f-1p40fi - - ---- _ _ I -� --_- - �- - --_--- -- ft - 1 -- -- -MIPA - -_ �- --- - - 128- �Q Gl�IQ �4 _ 127-------1 �_� �_ - ._L_ - �_ - -_��_ - �111IRA XT - 10.00 ft- .-._I_. -------- --- - _- 126 - MG- Bl D 3 1T - 1UL ! - - -- I -- - --- - - T - - -�--- - M1BA� 131�UXTQft- - -- - -- --- T -- 125� -----n�-� _-1------�-._. t G1�l p.4 - —r— - -- - -- ---� -- - -- F- T ---- -- J--- ---- -- - ---I - --- a -- --- -- - --�--- - -�1 RD &T - 10.00 ft- - -F -- - -�-_ - - LQB 123II - 0_,QO-- - -1- - _ --- -- - - —T—.- - -- - _ - _ - -_ _ -- _ -- - _- _ f IN] RAf}E A -BASE - - -- - - - - �- - - -- ---- J - ---- -� --- -- �- - - - _- �- 00 t + LO 00 + O 0) + LO d) t CD O t LO O LO o O N t t + + LO- N t m t co co M M M � � •cp � � � d' a Q d Q ¢ Q a Q d d d a ,® tiC b�tlYC /io DIAMOND PRO® - ELEVATION VIEW 2 WALL 1 CONTINUED V " Aar N a (SCALE: 1 = 5'-0") No 6104 0 1 f '<:: Scale: �� VERIFY THAT THE BAR ABOVE STATE OF 1 - 5 -0 IS 1". IF NOT, ADJUST THE ANCHOR WALL ENGINEERING, LLC SCALE ACCORDINGLY. g 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK Proj. No: AF 21-022 Reviewed By: DJA FLORIDA REGISTRATION: 6043 fie` MINNETO (9 2) 933-8 55 MIN 5996 PHONE:CRT. OF AUTHORIZATION:127 4077 Date: 6/2/21 D— BY: MAH - ---- _ _- _ ___ __ _ -134 --€L=13"3 JII __ -- - _ __ 133 ®__- _--_� - - - - IQI- 132 131 y__ _ -- �MIRAGRID 3XT�- 10_OQft-_� 130 -RIP - pQft.__— 129 - - - - -------- -- -- - --= 128 - I MIRAGRID 3XTi- 10_OQft 127 1 MIRA ?-W- 3XTI- 10_OQft _ 126 - - - ( - -----I...-- - - �125 -- - - I I3A.QW_ 3X 0 OD 124 ----- --- _-_ - _ �MIRAGRID 3XT_OQft 123 EL=122.50 _ ------7-----77----_ �122 -- C1 LO LO SEE SHEET W7 FOR LEGEND AND NOTES. PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS. FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TAMPA, FL Sheet I of WALL ELEVATIONS I V\16 1 16 TOP OFWALL BEHIND WALL 132 132 131 131 130UL -_---� -- _--- __�-_- �@ _--_- -- 130 -- -_�--� Z_W L_�-__����__��_�_��__'��� ��__���'__��_�_��__���_ �� 129 128 �L---�--------- --�-------------�----------�------'--'--�-----J0 ------�------------�-----'-----�--------'--�----'-- IQ. 128 127 127 � ��^~ _�___��-__��_�_��__�_�_ 1�8 �L �0 �������__��-_ _��___���_� 1Q� 12G 125 l [ l T l T l T -- 125 124 134 .~�� 12 L---__ �- _�_ -��--��_~ 1 � ------ � � --�--- ------ L --��---��--���--�- � ----~- ------ � � � _____l______�_____� ------ ----- - - 123 122'�----- - ---- �_�--T� E�FV���-'- --�-f ----- |�� --��------�----�-��-----��---- ' - ��--- ---�- - --- 7- -----�- ----i-- - -- -|-- - - --1-132 _ _ _ _4- LO LO CD (0 .- .­ 00 00 m m o LO C\1 04 LO LO *` LO "O LO TOP OFWALL 131 130 128 128-L { l L � g����0��-_�__ 137�-���~ -- - --- ---- 12G&ft_----�---_--~__---�-------'--_--�-----__------�---_--__--_ 1254 -1 � &�����I��D �L' OkAMONDpRnO-ELE\AJ|ONNEVV 1 WALL 1 (CONTINUED) |GRADE BEHIND WALL 131 1130 ---- MIRAG ___ 12Q --__ ____l___-_-L----_-J______JL-__---L_ ----_MQLWID_3XT - LOP ft-�-127 J-128 ---- ----f------�------1------f------�-- ---- �,�------f-------�------�------�-------�— � T�IQQ2� 120 ---- �-- Q3� _ ___�______�__�_ �- ----1------j --- ----�-- 1-135 ___�__ 124ft ~�-~--' 124 123 -- -- -____________-~_____________________ -- ____�____�___ _ 123 133-L______L_____J___-__l_____ | _____l______L_____J______l______L_----J 122 ������ ����|hJ����|�l� U h� o '-'_'._'' '---_--.'_-'----'-.'--.___ o90oBAKER ROAD, SUITE mm DESIGN ENGINEER: JOwu*o,nn m/wwsrnwmA, Mwnoa*o-5aoo FLORIDA REGISTRATION: a1mm pxows (95CERT. npAUTHORIZATION: urmr DIAMOND PROw-ELEVATION VIEW 2� WALL 1 (CONTINUED) NOTES: 1) LOCATIONS OFCORNERS SHOWN ARE APPROXIMATE AND SHOULD BEVERIFIED |NTHE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. 2)LOCATIONS OFUTILITIES SHOWN ARE APPROXIMATE AND SHOULD BEVERIFIED |NTHE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. » 1 VERIFY THAT THE BAR ABOVE /ur. /�worAoJuaTn*sSCALE ACCORDINGLY. Drawn By: I MAH LEGEND ' DETAIL NUMBER SHEET NUMBER ' INDICATES LOCATION OFSECTION CUT INDICATES REINFORCEMENT LENGTH AND/OR ELEVATION CHANGE ' INDICATES APPROXIMATE LOCATION OFINSIDE ANGLED CORNER ' INDICATES APPROXIMATE LOCATION OF90-OEGREEINSIDE CORNER PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS. FLORIDA REVISION DATES (SEE SHEET vwFOR REVISION *mron,): FL Sheet I of WALL ELEVATIONS �� | | // 16 30 MIL PVC LINER REQUIRED BEHIND REINFORCED ZONE--� | TOP OFWALL GRADE BEHIND WALL 13O� ' ' 130 129 f,U129 1284 l - _ - - J - - _ L _ _ - _ - �� �� � l __ _ _ _ _L- _ _ _ ��� �� �] _ _ _ �� �� �� l _ � �� _ �� _ i- _ �-128 127'��~~~~ Q����0�_'_�__ -- __L___~-_�__ -- _�__ --- __�___' J������T�J��_ - -- _�__ __�___' -- — ~�~�-127 -_�____ __L_ - ---' - _�__ i 1� ��_�'___��_'_��__��_��'��_'_ �� __���'___�___ ��_ _��-__��� |- 1� 126-� 125 124 1�3 -�---- ----' -- ----� -- -- '~^~^~' -- -- -- 124 123 7-------------------T---------------------------------------------------- 122-` _ _' _ _ �- _�L _ _ _ _ _ ] �� _ _ _ _ _ - _ '- _ _ _' _�L -' '_ _ _ �� �| _ _ '- _ �� ���� L _ - _' _ _ _ �� L- _ _� _� _ _ '] _'-- _ _ �- _ L _._ _ _ _' _L-__ �'BA ""^"__'�- -� T- _ _ - L_'FHN�G ----- -----� {�RABE _ _ _ ~-122 �� _ _ _ _ - � - _ __ _ _� __ _ _ _ - _ __ _ ___ - _ ___ _ _ _ _ _ � _ _ _ �� - �� ___�� _ _ _ - _ __ __ �� _ _ _ � _�� CD CD o �CD C14 C*14 CY) Cl) LO U'j r- m m m (0 no u, m to (0 'o (0 m m co � m � 1 _j TOP OF WALL 130-11 129 138-L 127--~~�-~�- 12 G 125 124 -~---- 123 �� �.50 122-7---__-L_'_BAGE8 � - ______ DIAMOND PROO-ELEVATION VIEW 3OMIL PVC LINER REQUIRED BEHIND REINFORCED ZONE GRADE BEHIND WALL I 130 128 128 -------~------------ 127 128 125 124 - --- -- -r QM' - - ---- - - --- - ----------- -----~----E-L-------------~~---~---------�----~---�--------------------L122 1�3 -�-�w�H -G�DEAT ----�------�------�------�------�------�------�------�-------�------- ----- ----- ----- ------L-----�------ ----- ------ ----- ----- CD 0 o � 04 04 ce) ce) LO � m 1­ DIAMOND PROO-ELEVATION VIEW No 6104 ju STATE OF ANCHOR WALL ENGINEERING, LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 NOTES: 1} LOCATIONS OFCORNERS SHOWN ARE APPROXIMATE AND SHOULD BEVERIFIED |NTHE FIELD PRIOR TO CONSTRUCTION OFTHE SEGMENTAL RETAINING WALL. 2)LOCATIONS OFUTILITIES SHOWN ARE APPROXIMATE AND SHOULD BEVERIFIED |NTHE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. Scale: 0 VERIFY THAT THE BAR ABOVE SCALE ACCORDINGLY. Date: 6/2/21 Drawn By: MAH ' DETAIL NUMBER SHEET NUMBER ' INDICATES LOCATION OF SECTION CUT �Nm ' INDICATES REINFORCEMENT LENGTH m� AND/OR ELEVATION CHANGE ' INDICATES APPROXIMATE LOCATION OFINSIDE ANGLED CORNER ' INDICATES APPROXIMATE LOCATION OF90-DEGREEINSIDE CORNER PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET wwFOR REVISION HISTORY): TAMPA, FL She WALL ELEVATIONS | W8 1 16 TOP OF WALL 130_,' 129-1 IUIIRD(,Rln '%YT _ 7 nn ff - GRADE BEHIND WALL � I . 130 129 128 f _J _ _ . _ _. _. _ -- ' _ _ _.._ _ __ -.-- .-__ i -_ . _.. __ _. __ _ _ _ _ __ - . 128 MIR,eG$ID 3XT 7.0 Lft T - 7.Q0 ft j 3XL-.Z.00 ft 127 _ _-_ -_ _ _ _ -__ _. _ _m1�SzRQ37 - - --- -. _ _ __. _ _ _.MLRAGRID -127 L — _ _ _.__ 126m1GBlD 3XTOSLft _ _ _ T -- - - -__: T _ _ -- - _-L��Q3iST - 7.00 ft NJ,J�tAG�ID 126 125 R125 aG$ID 3XL 7 OQft_ I - � - - _ _ I _ - - - R1:24MIR '. i � P 3XT 0-ft 1 - - I 3XT - 7.OQft: rT T ' MIRAGRQ 3LT - 7.CO ft 1 �- - _.. __ ._ k __ __ _- _ _ _ _ _. _ - - —� _ __ ._ _ -_ _BRA FBI XT 7.0Q� 124 123=MIRAGRID _ EL 122.50 _ ._ i _ _ ! , i _ _ - _ 1 i EL=12250 123 —_�—__—...'____-- 1224- - - - - - 1._ _ --_—__{ __ -----l-- j'-----------� _ BA�EOF WALL -- BA F B- GRADE SE - INI�FFE A _ _.._._.!. --- � - - - - - -122 o (O o L0 _ I o LO - -- _ I -_ o _ _. _ Ln o u') o I LO o to o �n LO 0 t t (D t (O t r__ t 1` 00. 00 0) t t 0) O t t C) + t r t N N + + � ti � I- � l - � T­ r t` 00 00 a0 t0 00 00 Q Q Q a Q Q d a a ¢ a d d Q a U) � co U) U) 0) U) co bi U) U) to co to U) DIAMOND PRO® - ELEVATION VIEW 1 WALL 1 CONTINUED W9 (SCALE: 1" = 5'-0") GRADE BEHIND WALL TOP OF WALL 131�--------.i---- -- - ---- --T_ -----I --- - - - ; --------- - --- - - - - I — - —E�t30 11� — .— .� __..._. _ __1 —..— — — __ —. __ __ .— —. -----.;..— _._ __ _._ ._.._ _. _T _ �.._. —_ — ._ 3 -- —_. __ —I—-E-L--136 17- 130 =- -- -- 129 j MIRAGRIDXT - 7.00 t ..! -- M I RAG$(D�}C XT - 7. 128 - - - - - - _I__. 127J MIRAGRID�X�7.00 ft __ _T 1- --, i �.. MIRAGI3XT 7.00 ft 126 MIRAGRID_ 7.00 ft MIRAGJD XT - 7.00 ft +_. + 125 IRA RID, X - 7.00 ft _-. _ MjRD XT - 7.0- ft I MIRAGRIDJXL-7.00 ft-(- T - - 7 -_ - T fVIjRAGFjIDXT - 7.6- 123 EL=122.50 _- _-I- _- _.J _._._._= L _._._._._.�._. _- 122 -- _ - _ - _ ! _! __ 1 _. __ __ _ - _ _-BASE OF -WALE -I- - INIHED 6RADE AIFBASE- -- L o (O o (O o (O o 00 00 00 00 00 00 00 00 U) U) U DIAMOND PRO® - ELEVATION VIEW END OF WALL TIES INTO - 2 WALL 1 CONTINUED BEGINNING OF WALL IN W9 (SCALE: 1" = 6-0") 90-DEGREE INSIDE CORNER ��W t 1111111/l7� ,� ,O'� C. _ No 610 eab r W z STATE NA u BI!l111 \A'Al� ANCHOR WALL ENGINEERING, LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Scale: 11 1 = 5'-011 Proj. No: AF 21-022 Date: 6/2/21 Ix W 131 130 -- �-129 L 128 - 127 126 -' 125 124 -�123 122 LO 00 H co NOTES: 1) LOCATIONS OF CORNERS SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. 2) LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE AND SHOULD BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION OF THE SEGMENTAL RETAINING WALL. LEGEND _ INDICATES REINFORCEMENT LENGTH AND/OR ELEVATION CHANGE - DETAIL NUMBER - SHEET NUMBER _ INDICATES APPROXIMATE LOCATION W1 OF INSIDE ANGLED CORNER X - INDICATES LOCATION 3 VVX OF SECTION CUT W1 - INDICATES APPROXIMATE LOCATION OF 90-DEGREE INSIDE CORNER 0 1 PROPOSED SEGMENTAL RETAINING WALL VERIFY THAT THE BAR ABOVE MULTI -USE COMMERCIAL IS 1". IF NOT, ADJUST THE ZEPHYRHILLS, FLORIDA SCALE ACCORDINGLY. OLDCASTLE COASTAL Reviewed By: DJA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): WALL ELEVATIONS Drawn By: MAH TAMPA, FL Sheet I of WESE OUTSIDE CURVE SAW CUT ' REQUIRED TO CONSTRUCT MITERED CORNER WALL FACE INSIDE CURVE SPLIT FACE AND END 1. ALWAYS START CAPPING WALL FROM THE LOWEST ELEVATION. 2. LAYOUT CAPS PRIOR TO USING ADHESIVE. 3. CUT CAPS TO FIT. VARIOUS COMBINATIONS OF LONG AND SHORT CAP FACES WILL BE NECESSARY FOR RADII GREATER THAN THE MINIMUM. 4. ALTERNATE SHORT AND LONG CAP FACES EVERY OTHER CAP TO ACHIEVE A STRAIGHT ROW OF CAPS. 5. USE EXTERIOR -GRADE CONSTRUCTION ADHESIVE TO SECURE CAPS. 6. REFER TO DETAIL 3 ON SHEET W10 FOR ADDITIONAL INFORMATION. DIAMOND PRO® 1 CAP BLOCK DESIGN DETAILS W1 (NOT TO SCALE) � f No 6104 luji STATE OF OT %Ot' I' i ANCHOR WALL ENGINEERING, LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON G. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION. 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 TOP VIEW 81281, FRONT VIEW SIDE VIEW DIAMOND PROD 2 3-WAY BLOCK VIEWS W10 (NOT TO SCALE) 8" 4 18" j 8 TRFN // G pqD i CORNER UNIT 12.5" 11" G 4 a 12" ad a a n n Q � nd 101. 17.25" 18" STRAIGHT UNIT CAP UNIT DIAMOND PROD 3 ISOMETRIC BLOCK VIEWS W10 (NOT TO SCALE) <iM�Ts oFFxc all c 1AR N. Gp , SOIL. DIAMOND P-•° QTYPICAL BASE PREPARATION (NOT TO SCALE) 11" MIP EXTEND GEOSYNTHETIC REINFORCEMENT TO WITHIN 1" OF THE LOWER BLOCK FACE 11" MIN. DIAMOND PROD 5 REINFORCEMENT CONNECTION DETAIL W1 O (NOT TO SCALE) Scale: 0 1 PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ERIFYTHE BAR AS SHOWN V IS V. FHAT NOT, ADJUST THOE E ZEPHYRHILLS, FLORIDA SCALE ACCORDINGLY. OLDCASTLE COASTAL Proj. No: AF 21-022 Reviewed BY: DJA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TYPICAL DETAILS Date: 6/2/21 Drawn By: MAH TAMPA, FL Sheet of Rno I U. "-- V IYIIIY. VVlvlr_r1%%1I C✓ Vr%r%Imu Ll1rx BASE LEVELING PAD 7° FINISHED GRADE 1 6" 1�De 0111,11111//1 s tea N NO6.104 - R - ju ® ° STATE OF y► 1111t4 DIAMOND PRO® 1 TYPICAL STEP-UP DETAIL W11 (NOT TO SCALE) Fr FILTER FABRIC (TYP) REINFORCEMENT LENGTH-----12 INCHES OF FREEDRAINING AGGREGATEEOSYNTHETIC REINFORCEMENT I r 6" MINIMUM COMPACTED I L GRANULAR BASE I I LEVELING PAD I 2'-0" Wos = WIDTH OF OVERSIZING 1 De = DEPTH OF EXCAVATION 1 L = LENGTH OF GEOSYNTHETIC REINFORCEMENT Wos = (2 " De) + L + 6" Wos DIAMOND PRO® 2 1:1 EXCAVATION OVERSIZING W11 (NOT TO SCALE) ANCHOR WALL ENGINEERING, LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Scale: AS SHOWN Prof. No: AF 21-022 Date: 6/2/21 FENCE BY OTHERS - MUST BE INSTALLED DURING WALL CONSTRUCTION SLEEVE AND NON -SHRINK GROUT AROUND POST SLOPE MAY VARY CAP BLOCKjj��, DIAMONDjj��/�/j� PRO BLOCK �''-------- I POST MUST PENETRATE TWO I ' �j/ LAYERS OF REINFORCEMENT I (MINIMUM) I I � I � I _L=_ GEOSYNTHETIC REINFORCEMENT j I FILTER FABRIC (TYP) ' SLEEVE AND NON -SHRINK GROUT AROUND POST SLEEVE INSTALLED DURING WALL CONSTRUCTION CAP BLOCK DIAMOND PRO BLOCK DIAMOND PRO® 3 FENCE BEHIND WALL IF REQUIRED W11 (NOT TO SCALE) i___ ___i___ ___i___ ___i___ ___i___ 1ST COURSE BELOW GRADE FINISHED r--- T T T T I GRADE i i i i i i 2ND COURSE BELOW GRADE L-------- -------- -------- -------- ------- J SPACING VARIES 50' MAXIMUM DIAMOND PROD 4 DAYLIGHT DRAINTILE THROUGH WALL W11 (NOT TO SCALE) 0 1 PROPOSED SEGMENTAL RETAINING WALL I I MULTI -USE COMMERCIAL VERIFY THAT THE BAR ABOVE IS1". IF NOT, ADJUST THE ZEPHYRHILLS, FLORIDA SCALE ACCORDINGLY. OLDCASTLE COASTAL TAMP, Reviewed By: DJA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): Sheyt of TYPICAL DETAILS W1 1 Drawn By: MAH FL 16 I PANEL 2 • \ • 1/ \ ............................ COURSE A COURSE B --� COMBINED COURSE A & B ' L TRIM OVERLAPPED PANELS AT O D U U U u U U U U U ' BACK OF BLOCK FACE TO REDUCE O OVERLAP. WHERE AREAS OF COURSE A O OVERLAP OCCUR, PLACE AT LEAST O 2 INCHES OF REINFORCED FILL ,'O USE A MASONRY SAW TO ACHIEVE BETWEEN GRID LAYERS. Ir DESIRED ANGLES. CUT UNITS TO COURSE B O LJ MAINTAIN RUNNING BOND. COURSE A PLACE ADDITIONAL PANEL AT CORNER TO PROVIDE 100% GEOGRID COVERAGE OF REINFORCED FILL. THIS PANEL SHOULD BE PLACED ONE COURSE ABOVE MAIN REINFORCEMENT. COURSE B DIAMOND PRO° 1 INSIDE ANGLE W/ GRID W12 (NOT TO SCALE) t 14 o 81043 4a mm noANCHOR WALL ENGINEERING LLC �w�r0 • ' o .� 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK ' MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 DIAMOND PRO® 2 INSIDE ANGLED CORNER W1 (NOT TO SCALE) H/4 - w J2O awl z 0_ Ow aX Z 0 w NOTE: PLACEMENT OF REINFORCEMENT EXTENSION ON SPECIFIED REINFORCEMENT ELEVATIONS. REINFORCEMENT H/4 BEYOND THE CORNER AT THE SPECIFIED REINFORCEMENT ELEVATIONS H/4 EXTENSION BEYOND BACK OF BLOCK PRINCIPLE REINFORCEMENT NOTE: USE ADHESIVE ON EXPOSED PARTIAL UNITS. DIRECTION CUT UNITS (X) TO MAINTAIN RUNNING BOND. DIAMOND PRO° DIAMOND PRO® 3 90-DEGREE INSIDE CORNER W/ GRID 4 90-DEGREE INSIDE CORNER W12 (NOT TO SCALE) W12 (NOT TO SCALE) Scale: 0 1 PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL THAT THE BAR AB AS SHOWN VERIFY IS1". IF NOT, ADJUST THOEE ZEPHYRHILLS, FLORIDA SCALE ACCORDINGLY. OLDCASTLE COASTAL -AMPA, FL Prof. No: AF 21-022 Reviewed BY: D,JA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): Sheer• of TYPICAL DETAILS W12 16 Y MAH Date: 6/2/21 Drawn By: 4 4 r 4 2 0 U J 0 x U z a THIS AREA MUST BE BACKFILLED WITH SELECT FILL, COMPACTED TO 100 PERCENT OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY. DEPTH 1 1 VARIES --- 1 1 ANY DISTURBANCE OF THE SOILS OUTSIDE THE 1:1 UTILITIES (DESIGNED BY OTHERS) EXCAVATION AREA MUST ALSOBE FILLED WITH SELECT FILL REINFORCEMENT LENGTH = L --I /\'�V` J 6" MIN. COMPACTED VI U GRAN GE SYNTHETIC GRANULAR BASE , LEVELING PAD i_= REJFORCEMENT 1 THIS AREA MUST BE BACKFILLED WITH SELECT 1 DP FILL, COMPACTED TO 100 PERCENT OF THE 1 F STANDARD PROCTOR MAXIMUM DRY DENSITY. 1 Wgf UTILITIES (DESIGNED Wgf = WIDTH OF GRANULAR FILL BY OTHERS) Dp = DEPTH OF PIPE L = LENGTH OF GEOSYNTHETIC REINFORCEMENT Wgf=(2.Dp)+L+6" DIAMOND PRO° 1 UTILITY PIPE BELOW WALL W13 (NOT TO SCALE) tkc I JN0 810 qScale: �� "y S - ATE Of `. AS SHOWN ANCHOR WALL ENGINEERING LLC �., `'` •.•a ,.......,. ' <. 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 Proj. No: AF 21-022 Date: 6/2/21 PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: DJA Drawn By: MAH CUT SLIT IN GEOGRID TO ALLOW MATERIAL TO LAY DOWN BEHIND STRUCTURE DIAMOND PRO BLOCK DIAMOND PRO BLOCK CAREFULLY CUT GEOGRID AROUND STRUCTURE ENTIRE STRUCTURE W/IN GEOGRID ZONE JLLY CUT BACK )GRID LAYER D STRUCTURE STRUCTURE AT BACK OF GEOGRID ZONE DIAMOND PRO® DROP STRUCTURE IN REINFORCED ZONE (IF REQUIRE (NOT TO SCALE) PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA OLDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): T' MPA, FL Sheet of TYPICAL DETAILS W13 16 r 4 v 4 r CAP BLOCK DIAMOND PRO BLOCK ' FILTER FABRIC (TYP) VA CS-1 CONTROL STRUCTURE (BY OTHERS) 7° \ /V/AA/�<'�//VAjV�/'//Vj�V A 12 INCHES OF FREE \VA DRAINING AGGREGATE j� \/\X /\\/\</\\� HAND CUT BLOCK UNITS \ \/AA/ A VA/AA/ TO WITHIN z" OF PIPE REINFORCEMENT /GEOSYNTHETIC F_ LL__LL_7 L_ J FACE VIEW , A�A� A �A/77//A WRAP PIPE IN FILTER 15" PIPE BELOW/THROUGH FABRIC TO REDUCE FINES WASHING OUT THE FACE WALL FACE (BY OTHERS) SECTION VIEW DIAMOND PRO° CONTROL STRUCTURE W/ PIPE EXTENDING THROUGH WALL (NOT TO SCALE) �' +J , Y) .j ' O 1 g � I Scale: 0 , PROPOSED SEGMENTAL RETAINING WALL MULTI —USE COMMERCIAL STATE o AS SHOWN VERIIFYTHAT THE BAR ABOVE IS1". IF NOT, ADJUST THE ZEPHYRHILLS, FLORIDA OLDCASTLE COASTAL TAMPA, FL ANCHOR WALL ENGINEERING, LLC SCALE ACCORDINGLY. Prof. No: AF 21-022 Reviewed By: DJA REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TYPICAL DETAILS She>t of v '' •., '" 'b� ' 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 Date: 6/2/21 Drawn By: MAH PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 VA 4 16 P P 2 0 0 0 x v z C NOTE: IF FENCE IS REQUIRED BEHIND WALL, SEE DETAIL 3 ON SHEET W11. 2 W6 NWL EL. = 117.50 4 1� 1 2 100 YR/24 HR = 127.56 6'-0" FINISHED GRADE /\/j�/ /j� %VAjAAj AA'VAjAAj' '\jVAj 4 6" /10 2,-0„ t10'-0" t8'-0" 3 i %\\//\ j / V/V/ xv/v/ /\�/711 �\\/ MIRAGRID 3XT, 10.0 FT ' 12 INCHES OF FREE ���A//A ' /i DRAINING AGGREGATES/�,/j//j//A /\�\VAV'�MIRAG RID 3XT 10.0 FT, % A, /AMIRAGRID 3XT' 10.0 FT����/ icy . , i i; ;- iw>• i/ \ MIRAFI TYPE 140N FILTER FABRIC (TYP)\//\\ V/VA'MIRAG RID 3XT,10.0 FTjAA/� \/ MIRAGRID 3XT, 10.0 FT .% x\/ jV/\>// MIRAGRID 3XT, 10.0 FT / \i //A//x / //,X� MIRAGRID 3XT 10.0 � 4 �I DIAMOND PRO° 1 WALL 1 STA 4+35 W15 (NOT TO SCALE) _tip 10 4<' d� �Scale: � V AS SHOWN VERIFY THAT THE BAR ABOVE 3 A IS V" IF NOT, ADJUST THE ANCHOR WALL ENGINEERING, LLC SCALE ACCORDINGLY. v a 1 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JON C. HUYCK pro No: Reviewed By: q. MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 AF 21-022 DJA PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 Date: 612/21 Drawn By MAH ROADWAY BY OTHERS PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA OLDCASTLE COASTAL TAMPA, FL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): Sheet of CROSS SECTION W15 16 k k k k k 2 0 0 z Q NOTE: IF FENCE IS REQUIRED BEHIND WALL, SEE DETAIL 3 ON SHEET W11. 2 W8 NWL EL. = 117.50 1 4 No 6104 . SiATEOF ` ANCHOR WALL ENGINEERING LLC 5909 BAKER ROAD, SUITE 550 DESIGN ENGINEER: JQN C. HUYCK MINNETONKA, MN 55345-5996 FLORIDA REGISTRATION: 61043 / 11 i {tit" PHONE: (952) 933-8855 CERT. OF AUTHORIZATION: 27077 1 W10 MIRAGRID 3XT - TRIM AT PVC LINER 6" MIN COVER 100 YR/24 HR = 127.56 7 6-0" FINISHED GRADE Scale: AS SHOWN Proj. No: A 21-022 Date: 6/2/21 4 61 --- 2'-0" — DIVERSION DITCH (3:1 MAX SLOPE, 2 FT DEPTH) 30 MIL PVC LINER 12 INCHES OF FREE DRAINING AGGREGATE �MIRAGRID 3XT. 7.0 FT!r, MIRAFI TYPE 140N FILTEIf FABRIC (TYP) d I / 4 DIAMOND PRO® 1 WALL 1 STA 6+90 W1 (NOT TO SCALE) 0 1 VERIFY THAT THE BAR ABOVE IS 1". IF NOT, ADJUST THE SCALE ACCORDINGLY. Reviewed By: DJA Drawn By: MAH PROPOSED SEGMENTAL RETAINING WALL MULTI -USE COMMERCIAL ZEPHYRHILLS, FLORIDA XDCASTLE COASTAL REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY): TAM PA, FL Sheet of CROSS SECTION VV1 6 16