HomeMy WebLinkAbout21-3384City of Zephyrhills
5335 Eighth Street
Zephyrhills, FL 33542
Phone: (813) 780-0020
Fax: (813) 780-0021
BAR-003384-2021
Issue Date: 01/07/2022
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
IIIIIIIII! I !!! I III III IM III IKI III III il* 0
1MI-411111DhIq 11141161111MA i
WIMIFTANMUIII 10M
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
ONTRACTOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS . WITHOUT APPROVED INSPECT101
CALL FOR INSPECTION 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
(!(INTERIOR
UPPORT COLUMN TO GABLE END COLUMN TO SIMPLE JAMB
IDE BASE RAIL CONNECTION TRUSS TUP CHORD 2x 3TRUSS TOP CONNECTIPERSPECTIVE) CONNECTION CHORD
3
2" x 3" SUPPORT-\ SIMPSON STRONG TIE
COLUMN S/H3 HURRICANE TIE FASTEN
N/ (4) #12-14 x 1-1/4" SDS
(3) #12-14 x 1-1/4"- SIMPSON! STRONGTIE
SDS 2" x 3" SUPPORT COLUMN L30 ANGLE TIE FASTEN
wl (4) # 12-14 x 1-1/4" SDS
(FL 10446.10-R4)
1/8 2" x 3" FISS S
2" x 3" BASE RAIL -3/4" x 2-3/4" x 6" WELDED J
INSERT HSS 14 GA STEEL TUBING
2" X 3" BASE RAIL
CORNER BRACE CONNECTION SIMPLE HEADER CONNECTION
3" NEADEL BOXED EAVE BOXED EAVES
CONNECTION CONNECTION
2" x 3" SUPPORT COLUMN (TYP) (TYP)
2" x 3" SUPPORT - a VaRles14,T0 ,/,z
COLUMN
SIMPSON STRONGTIE S/H3
HURRICANE TIE FASTENED
w/ 4) #12-14 x 1 1/4" SDS
(FL 0456,3 R3) 2" x 3" HEADER
SIMPSON <TRONGTIE
TP-15 TIE PATE FASTEN UP To 22' a°
W/ (6) #12-14 x 1-1/4" SDS SIMPSON STRONGTIE
N/ (6) # 12-114 xTE FA 1 /4N SDS
GABLE COLUMN TO BASE ��2"
x 3" BASE RAIL
RAIL CONNECTION ® x 3" BASE RAIL ,
*1/2" X 6" TAPCONS W/ UNIVERSAL FASTENING SCHEDULE HOR07_ONTAL R301` G
IS ALSO
EM PERMITTED
NJT 2" x3" x 14 GA BASE RAIL w/ PANELS ACROSS TRUSS TOP CHORD
IS ALSO PERMITTED 1/2" x 5-1/2" WEDGE ANCHOR
(1) WITHIN 12" OF EACH COLUMN NTS /# 12-14 X 7/8" SDS AND RUBBER
2" x 3" SUPPORT COLUMN IN FULLY CURED 3000 PSI CONC. WASHER 1/2 PURLIN SPACING
5' 0" O.C. MAX (TYP.) ALONG PANEL LAP
OPTIONAL FASTEN SHEA'HING 9" O.C. FEILD
SIDING (TYP) �- WASHERS (Tx -1/4" SDS AND RUBBER
1-3/4" x 2-3/4" x b" -�
SHOP WELDED INSERT
Zo
�\�\\/ CONC: SLAB 3000 PSI
/j\//j�j\// OVER b MIL VAPOR BARRIOR AND
/\\//\ \\// TERMIT TREATED SOIL
\/�/6xb REINFORCING WIRE MESH
FOR FIBER REINFORCMENT (TYP)
(2) #5 BAR MIN 3" EMBEDMENT „ " O.C.MAX(TYP)
CONT. (TYP) 5' 0" OAX (TYP)
NOTE: OR CLOSER
NEW CONCRETE/DIRECT ANCHORING FIBER MESH CONCRETE CAN BE USED # 12-14 x 1-1/4" SDS AND RUl6_,, TYr�, .L!l
AS AN ALTERNATIVE TO WWF REINFORCEMENT 3"/6"/3" O.0 ALONG LEADING EDGE
*1/2" X 6" TAPCONS W/
2-3/4" EMBEDDMENIT ALTERNATIVE LOCATION MAY
IS ALSO PERMITTED BE THROUGH THE BASE RAIL
2" MIN. FROM EDGE OF CONC. - 2" x 3" SUPPORT COLUMN
5' 0" O.C• MAX (TYP.)
2" x3" x 14 GA BASE RAIL w/- OPTIONAL FASTEN! SHEATHING w/
1/2" x 5-1/2" WEDGE ANCHOR SIDING (TYP) # 12 14 x 1 1 /4" SDS AND
(1) WITHIN 12" OF EACH COLUMN! RUBBER WASHER 9" O.C.
I FULLY CURED 3000 PSI CONC. 1-3/4" x 2-3/4" x 6" FIELD (TYP)
SHOP WELDED INSER-
1-3/4" x 2-3/4" x 6"
SHOP WELDED INISERT _
xy
2" x 2" 15 GA HSS STEEL
TUBING CORNER BRACE
O a
UNIVERSAL FASTENING SCHEDULE VERTICAL
ROOFING PANELS ACROSS PURLINS
NTS SIDELAP FASTENERS FIELD PANEL FASTENERS
#12-14X7/8"SIDS #12-14X1-1/4"SDS
1/2 TRUSS SPACING 9" ON -CENTER ALONG
ON -CENTER ALONG FIELD TRUSS TOP CHORDS
PANEL SIDELAP
FASTEN SHEATHING 9" O.C. FEILD
w/ #12-14 x 1-1/4" SIDS AND RUBBER
WASHERS (TYP)
2-1/2" x 1-1/2" HAT CHANNEL
ROOF PURLIN 48" O,C. (TYP)
FASTEN SHEATHING w/ #12-14 x 7/8" SDS
AND RUBBER WASHER 1/2 PURLIN
SPACING ALONG PANEL LAP
F-T
2" x 3" TRUSS TOP CHORD - �\
5' 0" O,C, MAX
BOXED EAVE
CONNECTION
(TYP)
SIMPSON STR�NIG Rl
TP-15 TIE PLAT . lN;r I
t t--
SIMPSON STRONGTIE TP-47 1) AT
EACH SYMETRIC TRUSS FACE
FASTENED w/ (8) #12-14 x 1-1/4'
SIDS CENTERED ABOUT JOINT
PLANE
BOXED EAVE
_ ,z
12
...- } v `.Vi'!'F_'r:.o , 12 -ato 4/12
t f
RUSS' CO�(NJE -T N �-
SIMPSON STRO TIE (�(P r� SIMPSON STRONGTIE TTIJUSS CONNECTION
TP-15 TIE PLATE FAST -- -TP, l.��-TIi,PLATE �!�tfyllj
W/ (6) # 12-14 x 1-1/4" SDS w% (b) # 12-14 x 1-1/4" SDS
(TYP)
FROM 22'-1" - THRU 26'-0" FROM 26-1" - THRU 30'-0"
BOXED EAVE
CONNECTION
12 (TYP) Z
VARIES$,TO 4/12 �'!AR!ESi(xT0 ,/12
k.
JTION SIMPSQ GHE SS ONNECTION
TP-1 5 1 T
FROM 36'-1" THRU 40'-0"
TRUSS CONFIGURATIONS
r NTS
(2) #12-14 x 1-1/4u SELF DRILLI
SCREWS (1
TRUSS WEBING 2" x 2"
HSS STEEL TUBING
TRUSS TOP CHORD
3" x 2" HSS STEEL
TUBING
x 1 1/2" 18 GA HAT CHANNEL
PURLIN 48" O,C (N
2-14x 1-1/4" SELF
LING SCREWS (TYP)
TRUSS TOP CHORD
3" x 2" HSS STEEL
31NG
I I SUPPORT COLUMN
# 12-14 x 1-1 /4" SIDS AND RUBBER 1-3/4" x 2-3/4" x 6" WELDED 2" x 3" HSS STEEL TUBING
VJASER 3"/b"/3" O.0 TYPICAL ROOF INSERT NHS STEEL TUBINGALONG LEADING EDGE TYPICAL TRUSS PURLIN ATTACHMENT TYPICAL BOXED
CONNECTIONS EAVE CONNECTION
,�9�� 9 9 2" X 3" TUBE SECURED TO LEGS
- tI_c' 5' 0" MAX - ABOVE DOOR W/ 2" X 2" ANGLE
FASTENED TO LEGS W/(2) #12-14 X 3/4"
FASTEN SHEATHING 9" O.C. FEILD SELF DRILLING SCREW PER FACE
w/ # 12 14 x 1-1 SHEATHING
SDS AND RUBBER 2" x"3" TRUSS TOP CHORD 3' 4" +/- =.I
2 X 3" TUBE FOR LEGS SPACED FOR -
WASHERS (TYP) 5' 0 O.C. MAX 5' OC OR CLOSER (TYP) I 5' OC OR CLOSER (YP) PACED a' rnAx
2-1/2"x 1-1/2" HAT CHANNEL
ROOF PURLIN 48" O,C. (TYP)7- DOOR FRAME ABOVE
X 3" TUBE SECURED TO LEGS
,
ABOVE WINDOW W/ 2" X 2" ANGLE���
FIELD FASTENING PATTERN �r FASTENED TO LEGS WI(2) S #12-1REWS 4 X FACE
m SELF DRILLING SCREWS PER FACE
NTS I #12 X 2" SELF DRILLING SCREW--,
4 MIN, CONC. SLA -(3000 PStJ" , \/�%/\/\/' I -
OVER 6 MIL VAPOR BA�22RIO;;AND \/\� \\ \\ 3° 3° 3" 3• 3° #12 X 2" SELF DRILLING SCREW 1 "' o FLAT HEAD (TYP)
TERMIT TREATEQ,S I `: \///\/// -� ,o FILL ALL N/IANF. PRE DRILLED
\ \\/ \ I�� a° b°+ a FLAT HEAD (TYP) I HOLES
.,
6x6 REINFORCING WIRE MEST s' " \"�\\/- 2" X 3" TUBE SECURED TO HEADER AND 2" X 3" TUBE SECURED TO
"K' \ 2" x 3" SUPPORT COLUMN! �� BOTTOM RAILING - - HEADER AND
OR FIBER REINFORCME,NT.I_(IXP_).-•----•�_�--' � i
5' 0" O.C. MAX (TYP.) OR #12-14 x 1-1/4" SDS AND RUBBER i, _ W/ 2" X 2" ANGLE FASTENED TO LEGS W/(2) #12-14 X 3/4" BOTTOM RAILING
(2) #5 BAR MIN 3" EMBEDMENT CLOSER WASER 3"/6"/3" O.0 2 x 3" TRUSS TOP CHORD - SELF DRILLING SCREWS PER FACE W/ 2" X 2" ANGLE FASTENED
5 0 O.C. MAX
CONT, (TYP) ALONG LEADING EDGE TO LEGS W/(2) #12-14 X 1-114"
NOTE: I BOTTOM RAIL TO REMAIN SELF DRILLING SCREWS PER FACE
FIBER MESH CONCRETE CAN BE USED , 2-1/2" x 1-1 /2" HAT CHANNEL CONICFOUNDATION b„
7
AS AN ALTERNATIVE TO WWF REINFORCEMENT NEW CONCRETE/OFFSET ANCHORING r ROOF PURLIN 48" O.C. (TYP) 6" - AFTER WINDOW INSTALLATION METAL SIDING
UNIVERSAL 'FASTENING SCHEDULE SIDING
PANELS ACROSS SUPPORT COLUMNS BOTTOM RAIL TO REMAIN OR AND "J" TIANNEL WILL BE ADDED TO MAKE
LEADING EDGE FASTENING PATTERN MAY BE CUT OUT PER CUSTOMER WEATHER TIGHT
NTS NTS REQUEST
WINDOW INSTALLATION DETAIL
OPTIONAL
SIDING (TYP)
NOTES:
1. ALL HAT CHANNEL SHALL BE A MINI. OF
18 GA.
i 2" x 3" SUPPORT COLUMN 7 2" x 3" SUPPORT COLUf N
5' 0" O.C. MAX (TYP.) 5' 0" O.C. MAX (TYP.)
2, ALL STRUCTURAL TUBING SHALL BE A MIN.
1/2" x 4" THOUGH BOLT, NUT, AND OF 14 GA.
WASHER ASSEMBLY (TYP) OPTIONAL
SIDING (TYP) 3. ALL UNIVERSAL STEEL SHALL BE A MINI. OF
I�YNATURAL. 29 GA STRUCTURAL STEEL PANELS AND H,AI/E
GROUNJI'� �` EXISTING A YEILD STRENGTH OF 80 KSI OR ANOTHER FBC
PAVEMENT APPROVED PANEL,
�0 r-
-
CUT AND CORE EXISTING ASPHALT
FLORIDA APPROVED 1/2" x 30" AUGER AND BASE TO UNDISTURBED EARTH
ANCHOR FASTEN WITHIN 12" OF SUPPORT SECTION
COLUMNS. MIN 24" EMBEDMENT HEX HEA[
SELF DRIL
FOR ALL
NO FOUNDATION/BARE GROUND
2" x3" x 14 GA BASE RAIL w/
1/2" x 5-1/2" WEDGE ANCHOR
(1) WITHIN 12" OF EACH COLUMN
2" x 2" x 20GA STEEL ANGLE
FASTENED TO 2" x 3" BASE RAIL
V// (2) #12-14 x 1-1/4" SDS OR WELDED
TO INSIDE FACE
t-
Z
z MIN. 4" THICK SLAB o
LU
EXISTING SLAB MAY BE USED ONLY WHEN
SLAB IS IN SATISFACTORY CONDITION!; N O CRACKS W
/FISSURES, \MINIMAL SLOPE/UNDULATIONS. z
z SLAB MUST ACT AS A SINGLE SUPPORTING UNLIT. �
L Q
FOUNDATION CONTRACTOR TO M
PROVIDE FOR MIMUMUM SLOPE
" OF 6" IN FIRST 1 G AWAY FROM FOUNDATION
(SECTION R401.3 FBC6-2017)
FOUNDATION AND ANCHORING
EXISTING CONCRETE/DIRECT ANCHORING
NTS
16
REAR OF LOUVER COVERED W/
WIRE MESH BUG SCREEN!
FASTEN W/ (1) #12-14 X 1-1/4"
SIDS PER CORNER (TYP)
CODE REQUIREMENT T IN' PER FT' OF ENCLOSED BUILDING
TOTAL ENCLOSED BUILDING = 600 FT'
EQUIVALENT FLOOD OPENING = 192 IN' EACH (25% REDUCTION DUE TO FINS)
= 144 IN' EACH
TOTAL PROVIDED (5)= 720 IN'
FLOOD OPENING DETAIL (ONLY USED WHEN
FINISH FLOOR IS BELOW BFE)
NTS
J
FIELD LEADING EDGE LENTS
DESCRIPTION r r DOOR INSTALLATION DETAIL_ _
ZONE 1 ZONE 2 ZONE 3 NTS
MAXIMUM UPLIFT DESIGN! PRESSURE 34,3 37.7 52.8
FASTENER PATTERN! 9"-9" 9" 9" 6"-3'-6"-3"-6"
SUPPORT SPACING 48" O.C. 48" O.C.
``DESIGN! PRESSURE BASED ON A SAFTEY FACTOR OF 2*
40' (MAX,) x UNLIMITED (MAX.) MODEL
(ALL FRAMING SHALL BE 2"xX RECTANGULAR TUBING)
(NOTE: WHEN OVER 26' IN WIDTH USE CO'_LAR TIE DETAIL
OR TRUSS DESIGN STYLE)
FASTEN W/ (2) # 12-14 X 1-1 /4"
SIDS (21 ON BUILDING SIDE
(2) O LEAN TO SIDE
OPTION LEAN TO
20'-0" MAX SPAN!
IS ONLY USED WHEN
ERTICALL Y INSTALLED
1 GA VERT COLUMN
T EVENLY
OVER 1.75" X 2.75" X 6"
�ALV TUBING
EEVE
ANCHOR TYPICAL
SAX.) ONLY IF REQUIRED
NON- CONIC FOOTINGS)
w1'
SITE SPECIFIC DESIGN PLAN
NTS (NOTE: SEE SECTION A -A FOR ANCHORING DETAILS)
GA. STEEL ROOF
PURLIN! SCREWS #12-14 x 1-1/4" AT 9" O.C. (TYP.)
COLUMN SCREWS 12-14 X 1-1/4"
SELF DRILLING SCREWS
a�
V
18 GA. GALVANIZED 2" X 2"
FASTENED TO 2" X 3" ROOF RAFTER
V// SIMPSON STRONGTIE TP-15 AND
#12-14 1-1/4" SDS
(6) x
"
o -
- 2"x2" 14 GAUAGE COLLAR TIE REQUIRED
FOR SPANS GREATER THAN 26'
PLACED 1 /3 DOWN FROM PEAK
b
w
COMPONENTS 41D CLADDING exp=B, c J=0.00 (Open))
PRESSURE PSF
VELOCITY
ZONE
ULTIMATE
ROOF VIALLS
A�JG�Toh17 5 A�J? P W11171
140 MPH
14.3 21.5 35.9 +14.5 17.6 +14.3
17.4
COMPONENTS AND CLADDING ex =B, c i=+/-0.18 Enclosed
PRESSURE (PSF)))
VELOCITY
ZONE
ULTIMATE
ROOF WALLS
SAVG NORF,%-T-475-A'-IG-isA�TI
140 MPH
-17.6 -24.7
-38.11 -+-17.7 1 -20.8 1 + 17.5
1 -20.6
COMPONENTS AND CEDING ex =B, qcpi=+/-0.55 Partial) Enclosed
PRESSURE PSF
VELOCITY
ZONE
ULTIMATE
ROOF
WALLS
5wG-ITO[
r2FTA_
5 AVG-F)wLLEC
140 MPH
-24.2
-31.4
-45.7
+22.4
27.4
+24.1
27.2
WIND SPEED VS, LEG SPACING
AND CLADDING TABLE
DESIGN
VELOCITY
ULTIMATE
4' ON CENlTER
5' ON CENTER
140 MPH
29 GA.
29 GA.
Z
140 MPH ~
rr
U
BUILDING TYPE
0
a� o
10
LOCATION
***all figures updated as of 12/28/18***
O_
<
F � C) }
GENERA NOTES co
l . ALL CONCRETE WORK SHALL BE 3,000 P.S.I. AT 28 DAYS.
14-1
2. MINIMUM SOIL BEARING SHALL BE ASSUMED AT 2,000 P.S.F.
3. ALL CONSTRUCTION SHALL BE PROVIDED IN ACCORDANCE a
WITH THE 2020 7TH EDITION FLA. BLDG, CODE AND ASCE 7 16,
THESE PLANS INCLUDE DESIGN FOR ALL WIND
4. ALL SIDING AND ROOFING TO MINIMUM OF 29 GAUGE
ATTACHED TO THE COLUMNS AS SHOWN AND CONSIDERED TO
BE A MIN. OF 3 SPAN.
5. FOR ZONE LOCATIONS SEE FBC FIGURE 1609(c). THE
COMPONENTS AND CLADDING LOADING CHARTS THIS SHEET.EPI
6. DESIGN! LOADINGS:
WELDING TABLE
1/8
FaLEr
r/8
1111/ ua
SQL'hRE
ua
Burr
7,
8.
DEAD LOAD = 4 PSF
ROOF LIVE LOAD = 20 PSF
DOOR AND WINDOW DATA: PER TABLE
ALL WINDOWS AND MAN DOORS MAY USE # 12-14X1-1 /4" LONG
F
SELF DRILLING SCREWS IN LIEU OF THE V'JOOD SCREWS WHEN
z
Lij
ENGINEERED PERMITS INC.
CONNECTING THE UNITS TO METAL FRAME. FOLLOW THE
311 SOUTH WOODLAND B!VD.
MANUFACTURERS SPECIFICATIONS FOR LOCATING CONNECTORS.
SUITE
9.
TYPE OF CONSTRUCTION TYPE II-B
BUILDING CATEGORY (II)
DEILMID, FL32720
10.
CORNER BRACES REQUIRED ONLY REQUIRED VNTH WIND SPEEDS
PHONE: 386-734-0830
GREATER THAN OR EQUAL TO 140 MPH OR AS CALLED OUT ON PLANS.
FAX: 386 734 8226
CERT NO.26298
EMAIL: epiftieng.net
ALL WORK SHALL COMPLY WITH PFI I:VAIt Irdc-:
CODES FLORIDA BUILDING CODE,
NATIONAL ELECTRIC CODE,
AND Thin CITY Or ,?FPHYRHILLS
ORDINANCEvc
-REVIEVV UAI'E
CITY OF ZEPH` RFIILf
PLAN EXAMINER
HW- z
2"X3" RECTANGULAR TUBING CIO J
OVER INSERT FAC RY WELDED ROOF (29 GA.) C� z
TO HEADER Cj CDm
I
i
I
to
2" x 3" x 14GA STEEL - --
TUBING
I I
II
COLUMN LEG FROM
BASE RAIL. TO HEADER FASTEN! i
°
u_O FACTORY 3X3 TRUSS
O
HEADER
FASTEN!
HEADER TO COLUMN
LEGS
INTO FACTORY WELDED INSERT
rz
W/ 2 #12
( )
14 X 1 1/4" SELF
DRILLING
ON BOTTOM OF HEADER 1
MID
SCREWS
PER SIDE (TYP)
xo
oz
Z w
¢U
�0 8'-16' (VARIES)
OPTIONAL GARAGE DOOR
5'-0" (M.) -f-- 5'-0" (MAX.) - - 5'-0" (MAX.) -V- 5'-d' (MAX.) - - 5'-0" (MAX.)-- 5'-0" (MAX.) -�-- 5' 0" (MAX.) AX-=
UNLIMITED MAX
SIDE ELEVATION W/OPTIONAL GARAGE DOOR
NTS
NOTE: SEE SECTION A -A FOR ANCHORING DETAILS
(NOTE: ALL FRAMING SHALL BE TxT RECTANGULAR TUBING)
ROOF (29 GA.)
NOTE:
SIDING SECURED BY #12-14-1/4"
SELF DRILLING SCREWS
AT 9" O.C. AT EACH FRAME.
� =D
C/D
m
J O�
w
U
W
F-
U
W
W
�T
r
CJD
5'-0 (MAX.)--5'-U"(Mm.) -i 5'-0"(!41AX.)-
UNLIMITED (MAX.)
***SIDING MAY BE FASTENED WITH SEAMS (� f
IN EITHER VERTICAL OR HORIZONTAL DIRECTION*** SIDE ELEVATION
NTS
(SUPPORT WITH SIDING) �
NOTE: SEE SECTION! A -A FOR ANCHORING DETAILS
(NOTE: ALL FRAMING SHALL BE 2"x3" RECTANGULAR TUBING)
IF THIS ITEM WAS BEEN DIGITALLY SIGNED AND SEALED BY
MICHAEL J WOJTUNIA P E
e , , ,
7
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED
"- SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES, UNLESS THE RAISED SEAT_ HAS
BEEN UTILIZED,
a
DESIGN STATEMENT;
THESE PLANS WERE DESIGNED FOLLOWING THE 2020 7TH EDITION
no FT (MAX.) j OPTIONAL DOOR FLORIDA BUILDING CODE AND ASCE 7-16,INCLUDING CHAPTER 16 ON
38'x80" OR 48"x80"
FRONT, BACK STRUCTURAL DESIGN. AN ULTIMATE WIND SPEED OF 140 MPH,
40FT(MAX.) oR'EITHER (3 SECOND GUST) IN WIND EXPOSURE CATEGORY "B" THIS STRUCTURE
COLLAR TIE DETAIL AND POST BRACING DETAIL FRONT ELEVATION SIDS
NTS
NOTE: SEE SECTION A -A FOR ANCHORING DETAILS
(NOTE: ALL FRAMING SHALL BE 2"x3" RECTANGULAR TUBING)
�1�11
°
;
1
.,
a
::
„_ el
W
n
W
HAS BEEN DESIGNED AS RISK CATEGORY II. THE COMPONENTS AND CLADDING
NTS WERE DESIGNED BASED ON A WIND PRESSURE. THIS STRUCTURE HAS BEEN
NOTE: SEE SECTION A -A FOR ANCHORING DETAILS r r
(SUPPORT WITH A- DESIGNED AS EITHER AN OPEN/ENCLOSED OR PARTIALLY ENCLOSED STRUCTURE
(NOTE: ALL FRAMING SHALL BE 2"x3" RECTANGULAR TUBING) AS PER NOTED,
61712021 3:41:19 PM M:\Central Florida Steel\Dgn\MetalPrototype0l(Revised 12-30-20).dgJ
SHEET N0.
A- 1
DATE: 6171202