HomeMy WebLinkAbout21-2574City of Zephyrhills
5335 Eighth Street
.1, ��llmmm
Zephyrhills, FL 33542
ELCMISC-002574-2021
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 07/30/2021
1 r1mall Vr� fir- 's
ii JdkW&6?J I "'
accordance with City Codes and Ordinances. NO OC UPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CON TOR SIGNATURE
PEf IT OFFICE
THOUT APPROVED INSPECTION
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
ReceivedDate Owner's Name ®.�Phone Contact for PermidLng
LORENE STASHEEN Owner Phone Number6383 I
•. Address ��Owner Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 16383 BRADFORD WOODS DR ZEPHYRHILLS, FL LOT
SUBDIVISION JOAKS OF PASCO I .... 2 i ♦ 060
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED
NEW CONSTR
ADDIALT
SIGN DEMOLISH
e
INSTALL
E]
REPAIR
PROPOSED USE
SFR
COMM
OTHER
TYPE OF CONSTRUCTION
BLOCK
E]
FRAME
STEEL
DESCRIPTION OF WORK
ROOF MOUNTED?
SOLAR PV SYSTEM INSTALLATION - 11,16 KW
BUILDING SIZE L SQ FOOTAGE HEIGHT
✓ BUILDING $29,574 OO VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C.
=PLUMBING $
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATIONrc
i
6 a
/t r
=GAS ROOFING SPECIALTY l._.J OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY®
SIGNATURE IN REGISTERED Y / N J FEE CURREN L Y / N
Address License #
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
Address License #
PLUMBER COMPANY
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
Address License #
MECHANICAL COMPANY
SIGNATURE REGISTERED _ Y / N T FEE CURREN
Address License #
OTHER COMPANY
SIGNATURE REGISTERED L=Y / N FEE CURREN Y ( N
Address License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page, (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all now projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-760-0021
wilding Department
NOTICE OF DEED RESTRICTIONS. The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009,
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. if the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowners Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner' prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Weiland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement
- Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone"V" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall,
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
FLORIDA JURAT (F.S. 117,03)
OWNER OR AGENT CONTRACTOR 45,
Subscribed and swam to (or affirmed) before me this ' Wscnibr!d�and swom t affirmed) b is 's e's(
by L
Who is/are personally known to me or has/have produced o is re 2:Tnally known to me or as/have pT d.ced
as identification. identification.
Notary Public Notary Public
It
Commission No. miss ion No, 02
Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped
Joseph Tribou
Notary Public, State of Florida
My Commission Expires 12/07/�024,
Commission No. HH 69907
11911113M 1 V=W =ST
Permit Number
Parcel ID Number 063C)
NOTICE OF COMMENCEMENT
State of Florida
County Of'QCxt>C0
T14E UNDMIGNED hereby gives notice that improvements will be made to certain real prop", and in accordance with Section 713,13 of the
Florida Stabiles, the following information Is provided In this NOTICE OF COMMENCEMENT.
I-Desed0lOn Of property (legal description): 01� PC6 C-9 0 PO 113 t,07
8) Street Uob) Addrewl
7-General description of Improvaments: INSTALL SOLAR PV. SYSTEM
3-Owna Infonnadon or Lesm Infama-d-or N -the Lamm�contrsctad for the Improvemeft
GONNUM OJO! LA.1OVd5 6 &Wf
b) Name and address Of fee simple Weholder (if diffarent than Owner listed above)
c) Interest in pmperty-, iom
4Xonftctor InfOrmstion
a) Name and address: NORMAN PURKEY- SOLAR BEAR LLC- 6101 JOHNS RD STE 8 TAMPA FL 3. 3634
b) Telephone No.: 727.471,7442 Fax No.: (optional) NIA
&Surety (4 applicable, a co�y �Ofe pay�mentbond is �aftachWd)-
Name and addmss: N/A
Telephone No.:
c) Amount of Bond: $
6.Lander
a) Name and addrew, N/A
b) Telephone No.:
7. Pamns within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section
Florida Statutes:
a) Name and address-. N/A
b) Telephone No.: Fax No- (optional)
&a,ln addition to himself or herself, Owner designates wA of
to receive a copy of the Lienor's Notice as provided in Sedan 713.13 (1) (b), Florida Statutes,
b)Phone Number of Pow or entity, designated by Owner, --
9. Expiration date of noUce of commencement (the expiration date may not W before the completion of constwdon and final payment to the
e-,*r, but will be I year from the date of recording unless a different date is sRepitied):
.20
me this
The foregoing instrument was ack.TWedged before day of
4? by
for
for
pemarially Known F1 Produced ID
Type of ID OL
KI URAHMS
(typ of a0mrity ... &9, offim, Vustee, aftomey in fact)
(name of party on behalf of whom Instnirrient was exeurted).
%
Notary Signature
Print name
DocuSign Envelope ID: 36DED09D-D801-45A9-B6CD-23767B1EFEA9y
r
Y
a� ��.�� H
° `< ""
�
1�����N
4091 AMTC CENTER DR LARG07 FL 33764
Your Solar Solutions Provider
(727) 471-7442
�J�i�V1. URSC [F1 t�LAR.Cf>�in
EC13006630
SOLAR HOME IMPROVEMENT AGREEMENT
DATE:
CUSTOMER NAME (hereinafter, the "Customer")
July 08 2021
Lorene Stasheen
ADDRESS: 6383 Bradford woods drive
CITY, STATE, ZIP:
zephyrhills fl 33542
HOME PHONE NUMBER:
WORK PHONE NUMBER:
MOBILE PHONE NUMBER:
2398671423
EMAIL: lorene.theodora@yahoo.com T
J
This Solar Home Improvement Agreement (this "Agreement") is between Solar Bear LLC ("Solar Bear", "we" or "Contractor") and
you ("Customer") for the sale and installation of the solar system described below (the "Project" or the "System") at your home
�the "PropertX" or your "Home"). The Parties agree as follows:
1. Was a full years usage of the customers electric bills provided? YES NO
2If ! •oes the customer
understande cannotaa.. R % 0offset YES ED NO .
(Based3. Does the customer understand the ITC 26% TAX CREDIT is based on their taxable income? YES ED NO
IF YOU DO NOT PAY TAXES YOU DO NOT GET A TAX CREDIT
PROPOSED SYSTEM SIZE (100% OFFSET) PURCHASED SYSTEM SIZE
on 12 monthsprevious usage)
rW
x Check Here If Any Portion of the project
Total System Cost is Financed.
If checked, the Customer will receive a separate
agreement from the Finance Provider outlying
their terms and conditions.
I understand, that if I cancel, I will be held financially
responsible for the cost of the permit and any work that
may ha:1i
z
Sign Vti Stt�S��t�n
7/8/2021
Date
NOTICE OF RIGHT TO CANCEL. THIS IS A LEGAL BINDING AGREEMENT AND YOU MAY ONLY CANCEL THIS AGREEMENT PRIOR TOM I DNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE YOU SIGN THIS
AGREEMENT. TO CANCEL THIS AGREEMENT, PLEASE SEETHE ATTACHED NOTICE OF CAN CELIATI ON FORM FOR AN EXPLANATION OF THIS RIGHT. THANK YODU FOR YOUR ALLOWING US TO SERVE YOU
F-oaou -day 7/8/2V21
Customer Signature: C lows" ^ Date:
Date:
---.1,—er 7/tJ/2®21
Representative: I -4 ,9Date:
e _acemos®�aie_.
C "boo iyi1►iN►[a1►1a�l.�i�Cel:
8378 Foxtail Loop, Pensacola, FL 32526 j (850)712-4219 1 chaci��odwinen .coixi
July 26, 2021
To: Zephyrhills wilding Department
5335 811, St.
Zephyrhills, FL 33542
Re: Stasheen - Residential PV Roof Mount Installation
6383 Bradford Woods fir.
Zephyrhills, FL 33542
This letter is regarding the installation of a new roof mounted Solar PV System on the existing
residential structure at the address above. I have reviewed the attachment plan and have
determined that the roof mounted PV system is in compliance with the applicable sections of the
following Codes as amended and adopted by the jurisdiction:
2020 Florida Building Code 7th Edition, FBC
ASCE 7 Min. Resign Loads for Buildings & Other Structures
Per 2020 FBC, the Roof Mounted PV system will be subject to the following design criteria:
Design Wind Speed(V,jt) - 140nph 3sec gust, Exposure Category - C
The PV System consist of the nodules, railing, and connection hardware, The system will add a
dead load of approximately 3 psf to the roof.
The existing roof covering is Asphalt Shingle with min. 1/2" plywood decking and 2" x 4" roof trusses
24" O.C. The roofing, decking, and roof trusses are in good condition. The existing structure will be
adequate for supporting the additional PV dead load and wind loads.
The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the
Ironridge railing and the Sunmodo Nano Mounts. The attachments can be attached up to 72" apart
in roof zone 1., and 48" apart in roof zones 2e, 2r, & 3.'The mounts should be staggered, where
possible, to allow distribution of the design loads evenly to the structure. The mounts shall be
installed with a min. 5/16" lag screw with minimum 2-5/16" thread length.
Please see attached documents and contact me should you have any questions.
Sincerely,
D. Chad Godwin, PE 81360
Exp.02/28/2023
ASCE 7-16 CHAPTER 29 WIND LOADS - Rooftop Solar Panels Minimum Design Loads - Part 1: Enclosed(Hip, h<60ft, 28'<0<45°)
Risk Category
II
Table 1.5-1
Load Types
load, PSf
Basic Wind Speed (Ult)
Figure 26.5-16
Dead Load, D
3
Wind Speed (asd)
108
FRC R301.2.1.3
Weight of Ice, D,
0
Roof Angle
;:'�-�,
Earthquake, E
0
Effective Wind Area
19.50
ft`
26.20
Fluid, F
n/a
Wind Load Parameters
Flood Load, F„
n/a
Wind Directionality
K,
0.85
Table 26.6-1
Lateral Earth psi, H
n/a
Exposure Cat.
B,C, or D
C
Section 26.7
Live Load, L
n/a
Topographic factor
K,,.
1.00
26.8 or 26.8.2
Roof Live, L,
n/a
Ground Elevation Factor
K,
1.00
Table 26.9-1
Rain, R
n/a
Velocity Exposure Coefficient
K,
0,85
Table 30.3-1
Snow S
; 5
Array Edge Factor
e
1.50
29A.4 `Modulesarec ,idered
Exposed
Self-Straining,T
n/a
Solar Panel Equalization Factor
, ,
0.68
Fig. 29,4-8
Wind, W
see calc
Velocity Pressure
q„
21.75
psf
q,,=0.00256 K,K,,KdK,V'
Wind -on -Ice, Wi I
n/a
Mean Roof Height
h
1 ;�a
ft
In,
5
in
Noto lo.,Inetgnt
*hove ror0
0.4h
6,000
ft
21k2
10
in
"min dlstrr�arraysnan b�c,om the roof edge,
Game n[dge,or hip „dge
least horizontal
dim
=
In
0,25
in
11o116. If,
10% of least horizontal
dim
3.00
ft
dl
1.00
ft
uorf,oraai distance orcnogrrai m 1a 1edgy
Roof Zone Set Back
-
=
ft
d2
0.25
ft
ur,ao„+aida,arccI-, edgy"f ore Moreno
meed'e n<
h/B
0.50
0.5h
7.50
ft
1.51-p
9.00
ft
Figure 30.3-2G(Hip roof, h<60ft, 28'<0<45`)
Inn
GC1
GCS,
p =ge(GCf,)l-Pr)( /.,)
p=gr(GCp)(7e)( /.,)
i 2e 2r 3
-1.40 -1.50 -2.10 -2.20 uplift
0.70 0.70 0.70 0.70 downward
-31.24 -33,47 -46.86 -49A0 psf uplift
15.62 15.62 15.62 15.62 psf downward
Design Calculations for the Use of Attachment to Roof Truss/Rafter
Module Length
-1.40 -1.50 -2.10 -2.20 uplift
0.70 0.70 0.70 0.70 downward
-31.24 -33,47 -46.86 -49A0 psf uplift
15.62 15.62 15.62 15.62 psf downward
Design Calculations for the Use of Attachment to Roof Truss/Rafter
Module Length
C(t„)
Module Width
B
Module Area
A
Total Design Load (Uplift)
P,m ,�
Total Design Load (Downforce)
P,,,,;g„
Design Load per Module
T„ p
Design Load per Module
T_
Distributed Load (Uplift)
P";" uo
Distributed Load (Down)
Pd1,1, a,„,,,
Railspan Between Anchor Points
L
Point Load per Mount (Uplift)
R
Point Load per Mount (Down)
R
Specific Gravity G
Diameter of Lag Screw D
Pullout Value of W
# of Lag screws
Thread Length Td
Design Pullout Value per Mount W,
SAFTEY FACTOR SF
Max Cantilever M
20
31.24
-33 47
-46.86
-49.10
15.62
15.62
15.62
15.62
-609.24
-652.75
-913,86
-957.37
304.62
304.62
304.62
304.62
-93.73
-100.42
-140.59
-147.29
46.86
46.86
46.86
46,86
-562.37
-401.69
<-562.37
-294.58
140.59
93.73 '+,
93.73
46.86
306.8697
306.8697
306.8697 306.8697
... . 1 7' 1''`.
a ;
709,6363
709.6363
709,6363 709.6363
1 2r_ 2e
it
ft
ft`
psf
psf
Ibs T„f,=A*Pa x.'
Ibs Tar = A * Pn ,r,,
pit T„„/B*2
plf T,,„ / B*2
ft
Ibs
Ibs
29.4-7
29.4-7
Table 11.2A, NDS 2005, page 68 (SYP)
n
bs/in W=1800 G'W/'
n Table L2, NDS 2005
W,=W-#of Lags*T,
Calculation: SF=W,fR (Uplift)
Maximum Cantilever from Last attachment
24 1 16 1 16 8 in Max rail span * 33%
owi11 El!/lI`i
' e 1360 "
a
0 "
mmM W
wr` g 8 °saw
T OF
L
�f/J
f � � ��0
Ironridge XR- 100
- Sunmodo Nano Mount are secured to rafters
72" O.C. in Zone 1,
48" O.0 in Zone 2e, 2r
using 5/16" x 4.75" stainless steel Lag bolts.
- Subject roof has One layer.
- All penetrations are sealed.
0
Exposure Category - C
-Designed as per ASCE7-16
'3/6-16 X 3/4
*4EX HEAD BOLT
Z�/8-16
FLANGE tI T
General Notes: (Optional)
Sunmodo Nano Mount are secured to plywood decking
24" O.C. in Zone 1, 2e, 2r & 3
using (4) #6.3mm x 76.2mm stainless steel Lag bolts.
Subject roof has One layer.
All penetrations are sealed.
910 � 11
I I•ii
211x4" @ 24 0.CJ
Inverter Type:
Enphase IQ7PLUS-72-2-US
PV Panel:
(3 1) SIL-360 NX
Racking:
Iron Ridge
Total Wattage:
11, 160W
Roof Type:
Composition Shingles
Wind Load:
20 to 27 Deg
Fastener Type:
Use Sunmodo NanoMount
Lorene Stasheen
6383 Bradford Woods Dr
Zephyrhills, FL
33542
um
111SWIl kVill be d011C W MWIL&ZICtUrel- SpeC
Godwin Engineering and
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad(&
,,godwineng.com
OW I I
E C.
0
60
7 -M
A OF
06 "'A;
Z
'50LAR BEAR
6 101 Johns Rd, Ste 8
Tampa, FL 33634
727-471-7442
Date: 7/21/2021
Drawn byOFF
I
Rev Date: -
Page: S-2
Grounding Conductor
Flo uF for Home runs
to he bare #8 Awg
(1) Line 1
—
(1)Line 2
NEMA3R
PerCir
#8 AWGG THWN
Junction Box
Rao
(1) EGC
Black - Ll
Inside @ least 3/4" Conduit rbd on site)
Red - L2
_..
I Green - Ground
S}:stela Sheets the tirOUrldilsg regUil-CHIelIts of N1 C 690,43
llicludin2y the hab'L1 helo\
In Case of Emergency Call
Solar Bear
at 727-471-7442
EC #: EC 13006630
Inverters:
(31) Enphase 1Q7PLUS-72-2-US Micro Inverters
mum
(2) circuits of (10) Modules
(1) circuit of (11) Modules
Maximum Inverters Per 20A Circuit (13)
Load Side Connection
Rating
l Busbar Rating l
200
Main Breaker Size
175
Bus Rating- * 1 2 Main Break Size i65
!Max Allowable Load Side
65 j
Load Size Breaker Size
50
RATED AC OUTPUT CURRENT: 3ZilA
NOMINAL OPERATING VOLTAGE: 240VAC
Enphase Combiner Box
(1) - 20A Breaker
Per Circuit
3 Circuits
240 V
10/15A Breaker for Envov
Disconnect
Solar Combiner Box
X-IQ-AM l -240
Note:
-All wiring to meet the 2017 NEC and
Florida electric codes.
60A Disconnect
-Type of conduit to be determined
on site by contractor.
Install Will be done to Mall U 111CtUl-el- S
VLual i L,N, t3 <.coazireeE
60A Service Rated
Fused Disconnect
AC Disconnect
50A Fuse
4`6 AWG THWN
(2) Hot
(1) Neutral
48 AWG EGC
in Sri) least 3/4" Conduit Typical]
Main Service
175A
200A Bus l
To t
AC Max Output Current
13.31
t
AC Max Outpu_ Current* * 1 25°/a
-
16.64
Overcurrent Protection (A) -
20
No . of Current Carrying Cond
<4
-
- --- -
Conductor Gauge (AWG)
10 -
Enphase Total Output Ckt
AC Max Output Current
37.51
AC Max Output Current * 1.25%
46.89
No�ion (A)
50
of Current Carrying Cond
Conductor Gauge (AWG)
6
NEC LABEL NOTES:
1, THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY
WITH NEC 116.21(B)
2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT
WHERE THEY ARE INSTALLED,
3, LABELS TO BE A MIN LETTER HEIGHT OF 3/8" AND
PERMANENTLY AFFIXED.
4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC
REQUIREMENTS OF THE AUTHORITY HAVING
JURISDICTION.
'Godwin Engineering and
Design, LLC
50A 8378 Foxtaii. Loop
Pensacola, FL 32526
N D. Chad Godwin, PE
Chadr'a)godwineng.com
GEC
Load side connection Per 705.12(B)(2)(3)(b)
Use Matching or equivalent approved breaker if cleratincg
61:CNo IFS
t il,_ trout&d s%steni per 6E)0} 41(A)(4)
6F, mast be installed per 250.6 4
(ill(' natl,t lie cunt€ umis un-spl,ccd m i€rc- ersibf% splicct 1'f rn
IM t'EtQF N 4\Vhtl'a ICIt IC.0 _tOUrld 1 SIC Ili Of C 11tli.uous (€om
i11a� s to the Cx1st€11 sel ice u,u€ld S%,,tcm.
0 C' 111111t be niin 8 A tt'(i and installed in conduit
It (if,(' is nol in conduit it niu,t be =6 nlin
Disconnects will be Visible, lockable. adjacent to
and vvitlltn 10' of utility meter
All Labels & tlarkings for photw oltaic system 'e ill be
reflective and meet all requirements for NF'PA 1 1.12
FSIMTIITi
Lorene Stasheen
6383 Bradford Woods Dr
Zephyrhills, FL
33542
Date:
DrawnRevised by.
6101 JohnsRd, Ste ti
Tampa, III 33634
727-471-7442
Inverter Type:
Enphase 1Q7PLUS-72-2-EJS
PV Panel:
(31)
SIL-360 NX
Total Wattage:
11,16-OW
go
"'IMA00ft"
®1
# Modules (27)
Pitch: 27'
Azimuth: 187'
Iron Ridge Rail
17
a -RIM
Splice Bar
6
Sunmodo Nano Mounts
55
Iron Ridge UFO's
78
Iron Ridge Sleeves/End Caps
32
Combiner
2
Iron Ridge Ground Lugs
8
SIL-360 NX
31
Inverter Type:
Enphase IQ7PLUS-72-2-US
31
Pig Panel:
Meter Main
175A Breaker for de -rate
I
Racking:
60A Fused Disconnect
I
Total Wattage:
50A Fuses
2
Roof Type:
50A Breaker
20A Breakers
I
3
Wind Load:
Enphase Combiner Box
I
Fastener Type:
WERE
Proposed Mounting locations
R-2 31-3 11
Modules (4)
Pitch: 27' 61-011
Azimuth: 97'
Max cantilever is 24 as per manufacturer spec.
I
Max Cantilever == Max Span
3
Max cantilever is 16 as per manufacturer spec.
Max Cantilever = Max Span * (11)=48"*(1)=I611
3
Enphase IQ7PLUS-72-2-US
(3 1) SIL-360 NX
Iron Ridge
11,160W
Composition Shingles
20 to 27 Deg
Use Sunmodo NanoMount
Lorene Stasheen
6383 Bradford Woods Dr
Zephyrhills, FL
33542
Plans satist'.\, zones I B('-1510.7.1
Install will be done to Mail Ll 11ACtL1 I-Cl- SI)eC
IE C.
0
Godwin Engineering and
0
<)
Design, LLC
1360
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad ,(&
_/godwineng.com
0 %47rA 8 OF
0
0 P, Z�-
XX 4/
O'A!A L
Nit
6101 Johns Rd, SteV
Tampa, FL 33634
727-471-7442
Date: 7/21/2021
Drawn by: PF
Revised by:
Rev Date:
Page: S-IA
x im
INDUSTRY LEADING WARRANTY
All our products include an industry
leading 25-year product workmanship
and 30-year performance warranty.
35+ YEARS OF SOLAR INNOVATION
Leveraging over 35+ years of worldwide
experience in the solar industry, Silfab
is dedicated to superior manufacturing
processes and innovations such as
Bifacial and Back Contact technologies,
to ensure our partners have the latest in
solar innovation.
NORTH AMERICAN QUALITY
Silfab is the leading automated solar
module manufacturer in North America,
Utilizing premium quality materials and
strict quality control management to deliver
the highest efficiency, premium quality
PV modules.
E
DN;V GL
P-ER
Test Conditions
Module Power (Pmax)
Maximum power voltage (Vpmax)
Maximum power current (Ipmax)
NOCT
258
33.1
7.8
Open circuit voltage (voc)
V 44.5
40.4
Short circuit current (Isc)
A 1 Ok5
82
d Module efficiency
% 19.7
17,6
Maximum system voltage (VDC)
v
1000 . . .... . .... . ......... .. ... .. ..... . . .. ..
Series fuse rating
A
20
Power Tolerance
Wp
0 to +10
Measurement conditions: STC 1000 W/m2 - AM 1.5 - Temperature 25 'C - NOCT 800 W/nn' - AM 1.5 - Measurement uncertainty
< 3%
- Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +1 OW.
Temperature Coeffi lent I C
+0064 0/6/1C
Temperature Coefficient Voc
-0.28 %/oC
Temperature Coefficient Pmax
')/o/'C
NOCT 2'C)
46 'C
temperature
Module weight
Dimensions (H x_L xl-D)
Maximum surface load
Hail impact resistance
Cells
Glass
Cables and connectors (refer to installation
1832 Prim x 1000 mm x 38 mm
EM
o 25 mm at 83 km/h
72.13 in x 39.4 in x 1 .5 in
Backsheet High durability, superior hydrolysis and UV resistance, multi -layer dielectric film,
fluorine -free PV backsheet
.... ............
Frame Anodized Aluminum (Black)
Bypass diodes 3 diodes-30SQ045T (45V max DC blocking voltage 30A max forward rectified current)
Junction Box UL 3730 Certified, IEC 62790 Certified, IP67 rated
Module product workmanship warranty
Linear power performance guarantee
>_ 97.1 %end 1 11
IN
> 85A % end 251h year �t 82.6% end 301h
ULC ORD C1 703, LIL1 703, CEC listed***, UL 61215-1/-1-1/-2, UL 61730-1/-2,
Product IEC 61215-1/-1-1/-2***, IEC 61730-1/-2***, CSA C22.2#61730-1/-2, IEC 62716
Ammonia Corrosion C61701:201 1 Salt Mist _Corrosion _pULre Rating:,Type� Factory IS09001:2015
All states except California California
... Modules Per Pallet: 26 .. Modules Per Pallet: 26
"- Pallets Per Truck: 34 n Pallets Per Truck: 32
... Modules Per Truck: 884 nva Modules Per Truck: 832
*A Warning. Read the Safety and Installation Manual
for mounting specifications and before handling,
installing and operating modules.
**12 year extendable to 25 years subject to regis-
tration and conditions outlined under 'Warranty"at
www.silfabsolar.com.
***Certification and CEC listing in progress.
PAN files generated from 3rd party performance
data are available for download at:
www.silfabsolar.com/downloads.
Silfab Solar Inc.
240 Courtneypark Drive East
Mississauga ON _5T2Y3 Canada
Sil claE Tel +1 905-255-2501 1 Fax +1 905-696-0267
SGUR info@sitfabsolar,com I www.silfabsolar.com
Silfab Solar Inc.
800 Cornwall Ave
Bellingham WA 98225 USA
Tel +1 360-569-4733
1.5" [3
7-777=77==77
H�r,4)
E E�
E T,
E
E E
P
IF
C
C
1 02` 126—] 11
39'37"[1000mral
Data Sheet ' Enphase sAicroinverters
1 7 0.
cnonase
A
IQ 7 and 10,
arters
M
P ro i n,11" C I L C. ia i %4 a vi
The high-powered smart grid -ready
Enphase IQ 7 Micro" and LE'nphase IQ 7+ Micro -
dramatically simplify the installation process while
achieving the highest system efficiency.
Part of the Enphase IQ System, the IQ 7 and
IQ 7+ Microinverters integrate with the Enphase
IQ Envoy"", Enphase IQ Battery"', and the Enphase
Enlighten" monitoring and analysis software.
IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power -on testing,
enabling Enphase to provide an industry -leading
warranty of up to 25 years.
Lightweight and simp[e
Faster installation with improved, lighter two -wire cabling
Built-in rapid shutdown compliant (NEC 2014 & 2017)
Productive and Reliable
Optimized for high powered 60-cell and 72-cell* modules
More than a million hours of testing
Class 11 double -insulated enclosure
UL listed
Smart Grid Ready
Complies with advanced grid support, voltage and
frequency ride -through requirernents
Remotely updates to respond to changing
grid requirements
Configurable for varying grid profiles
Meets CA Rule 21 (UL 1741 -SA)
* The IQ 7+ Micro is required to support 72-cell modules,
Enphase IQ 7 and IQ 7+ Microinverters
INPUT DATA (DC)
107-60-2-US 107-60-8-US
107PLUS-72-2-US / lQ7PLUS-72-S-US
.... . ..... commonly used module partings'
235 W - 350 W
235 W - 440 W +
Modulp cornpatibdity
6& cell PV mocksles onJy
60-ceh and 7?-celi PV modules
Maximurn 4rpul DC vM13ge
48V
60V
Peak power tracking voftaije
27 V - 37 V
27 V - 45 V
Operating range
1611 - 48 V
16 V- 60 V
Mirt/olax start voItage
22 V / 48 V
22 V / 60 V
Max DC short circuit. current (moduie rsc)
15A
15A
overvollage class DC Pori,
4
f X; port backfeed rurrent
0 A
11 A
PV array
I x If tifigrounded array; No additiomtf
DC side protection required;
AC side rifotection requires max 20A pet branch circua
OUTPUT DATA (AC)
10 7 Microinverter
10 7+ Microttivetter
Peak output power
2,501VA
295 VA
Maximum continuous Output power
240VA
290 VA
claminai(L-L) volrage/rangelt
240 V I 2,08 V 1
'240 V 208 A
211-264 V 183-2129 V
211-264 V 183-229 V
tviaximurn continuous output current
10 A (1240 V) 1A 5 A (208 V)
1,21 A (240 V) 1 .39 A (208 V)
eltodimal frequency
60 Rz
60H ' z
Extended frequency range
47 - 68 Nz
47. 68 Hz
AG short circuit fatilt current over 3 cycles
5-8 Antis
5,8 Ames
olaxirnurn units per 20 A (L-L) branch circuiP
16 (240 VAC) 13 (208 VAC)
13 (240 VAC) 11 (208 VAC)
Overvoltage class- Ar. port
it!
M
AC port backfeed current
0 A
A
Mower factor Setting
1,0
110
Power factor (adjustablre)
0. ! leaaing ... 0,7 tag ging
0_7 feacing-, 07 nigging
EFFICIENCY
@240 V @208 V
@240 V @208 V
kwi "rency
qT61 97
CEC oteighted ef ficfericy
970 91', 9 -7, 0 'o
07,0 970
MECHANICAL DATA
fange -400C to +650C
Relative hurnidity range 4%- to 100-6 (condensmg)
CofmeCtor type (IQ7-60-B-US & 3 7PLUS:72-6-US) Friends PV2 (MC4 intermateable)
Adaptors for Inodukrswrth MC4 or VTX connectors:
PV2 to MC41 order ECA-G,"40-S22
PV2 to UTX: order ECA-S20-S25
Dirt -tensions (WxHxD) 212 rnm- Y 175 mm x 30,2,nm (without brackeel)
Weight 1,08 ka (2 38 lbs)
Cooling Natutal core ttectJort- No farts
Approved for Aet locations Yes
Prolutiondegree P03
Enplacure Class rl doubte insulated, corrosion, resistant polymenc enclosure
Environnnoolsli category /UV exposure rating, NEW Jy0e6 outdoor
FEATURES
communication i Power Line Communicrivon (PLG)
Moriitorrn,g Enlighten Manager and tvilyEnfighten momtortfig OpVons,
Both options require instailaborr of w-i Entahasp IQ Envov,
compliance CA Rule 21 (UL 1741-SA)
UL 621_,r9-1,4JL1741/fEEE1547, FCC Part'! 5 Mass B, 10ES- 0003 cIass B.
CANJCSA-C22.2 NOY, 107 1 -01
This product is UL Listed as PV Rapid Shut Do,m Equiprnsnt and conforms with NEC-2014 arid
NEC-2017 section 690,12 and 22.1-2015 Rule 64-21t-, Rapid Shutdown of PV Systems, for AC
and DC conductors, when instai"ed according manufacturer's Instrucfions,
1. No enforced DC/AC ratio, Seethe compatibility calculator at
2. Nominal voltage range can be extended beyond nominal if required by the utility,
3. Limits may vary. Refer to local requirements to define the number ofmirroinverters per branch in your area.
To learn more about Enphase offerings, visit enphasecom C-A ENPHASE, To learn more about Enphase offerings, visit enphase.com ENPHASE.
s, 2018 Enpl isse Erprq All rights reserved. All tr,,,demarks or brands usedarp the property of Fnphase E- ergy, iric,
e)'8-05-24
Data Sheet
Em7dhase Networking
E.n pj hi. a -5 e
IQ Comoinear 3
(X-1Q-AM1-240-3)
LISTED
To learn more about Enphase offerings, visit enphase.com
The Enphase IQ Combiner 3 W with Enphase
IQ Envoy" consolidates interconnection
equipment into a single enclosure and
streamlines PV and storage installations by
providing a consistent, pre -wired solution for
residential applications, It offers up to four
2-pole input circuits and Eaton BR series
bUsbar assembly,
Smart
includes Q Envoy for communication
and control
Flexible networking supports ldli-Fi,
Ethernet, or cellular
Optional AC receptacle available for PLC
bridge
Provides 'Production metering and optional
consumption monitoring
Reduced size from previous combiner
Centered mounting brackets support single
stud mounting
Supports back and side conduit entry
Up to four 2-pole branch circuits for 240 PAC
PlUg-in breakers (not included)
80 A total PV or storage branch circuits
low=
Durable NRTL-certifiedNEMA type
3R enclosure
Five-year warranty
UL listed
Enphase IQ Combiner 3
MODEL NUM13ER
ACCESSORIES and REPLACEMENT PARTS (noi included, order seParately)
Enphave Mobil's Connect-
CIELLMODEPA-03 (4G / 12-year date plait) Plug and play it dustriai grade cellular modern with dalts plar, for systerns tip to 60
CELLMODEM-01 (3G / 5-year data plan) microinverters, (Avaitable *in the US, Canada, Mexico Puerto Rico, and the US Virgin Isla
C E LLM, 0 D E as- M 1 (4 G based LTE- V, / 5-ye a t dad a p i an} where there m adequate cellular service !rl the installation area,)
ConS�jMption MGnjj,,,whrc;* CT
CT-200-SPLIT Spht core current transfourfers enable whoh? home COnSUMPI=On Metering (+/-
11M
Systemvcpftage
h4ax, confinuous current rating (ouput to grid)
Brandh circuits (solar and/or storage)
Max, total branch, cirMt breaker rafing (input)
MECHANICAL DATA
Dimensions (WxHxD)
Weight
Air blent temperature f
Cooling
Power line carrier (cornmunication bridge vair), quantity 2
Replacement iQ Envoy pOnted circuit board (PCB) "or Combiner 3
,20/240 VAC, 60 riz
Up to fouir 2-poie Eaton BR series Distributed Generation (DG) bye, kefs only (not included
80A of distributed generation /90A wort Q Envoy breaker iachjded
15 kg (16,5 lbs)
Natural conve0k),% phis heat shield
Nile sizes 20 A to 50 A breaker iriptits- 14 to 4 AWG copper crinduclors
60 A breaker branch inprit: 4 to 1 ' 10 AWG copper conductors
Main lug combined output 10 try210 AING copper conductors
Neutral anti ground: 14 to 1/0 copper conductors
Atways foltoot locaf code rermirements 'or conductor sizing,
AftitOde To 2000 meters (6,560 feet'!
INTERNET CONNECTION OPTIONS
Effiernet Opbona�, 902,3, CaciEfor Cat 6) UTP Ethernet cable (._19ot included)
1111111M111
Compliance, Q Envoy UL 60601-IICANCSA 22.2 No- 61010-1
Consumption rnorritoring in requirteld for tDq3hfas�? Starage Systems,
To learn more about Enphase offerings, visit enphasearn
m
@ 2013 Enphasee Energy! A111. rights reserved. A I tiaderTiarks or brands in eis document are registered by their re,9pective owne,
201, 8-09-13 ChENPHASE.
A
A
RONRIDGE XR Rail Family XR Rail Family
S,fl,,ur Is Nw."-, Mllw-,Ys
Over their lifetime, solar panels experience countless
txtreme weather events. Not just the worst storms in years,
but the worst storms in 40 years. High winds capable of
ripping panels from a roof, and snowfalls weighing
-nough to buckle a panel frame. A
Sloped roofs generate both vertical and lateral
forces on mounting rails which can cause them
to bend and twist. The curved shape of XR Rails
is specially designed to increase strength in both
directions while resisting the twisting. This unique
feature ensures greater security during extreme
weather and a longer system lifetime.
Compatible with Flat & Pitched Roofs
W XR Rails are
R-ffl' compatible with
"110fe IronRidge offers
RON
4ffi, "T- "'o a range of tilt leg
M
Z 11 FlashFoot and
gO'*
,�
m 10 options for flat
other Pitched roof
attachments.r
roof mounting
r applications.
All XR Rails are made of 6000-series
aluminum alloy, then protected with an
anodized finish. Anodizing prevents surface
and structural corrosion, while also providing
a more attractive appearance.
XRIO
XR10 is a sleek, low -profile mounting
rail, designed for regions with light or
no snow. It achieves spans up to 6 feet,
while remaining light and economical.
6' spanning capability
Moderate load capability
Clear & black anodized finish
Internal splices available
FOINUM-315-341 MT,
32M
W, F 45,11MUOURK-TOW, AN, - 5
XR100 is the ultimate residential
mounting rail. It supports a range of
wind and snow conditions, while also
maximizing spans up to 10 feet.
10' spanning capability
Heavy load capability
Clear & black anodized finish
Internal splices available
XR1 000 is a heavyweight among
solar mounting rails. It's built to handle
extreme climates and spans up to 12
feet for commercial applications.
• 12'spanning capability
• Extreme load capability
Clear anodized finish
Internal splices available
`Table is meare to be P simpiKed span chiart for conveying general rail capabififies. Use approved certiNcaflon iet[ers for actual des igii gutdm-oe.