Loading...
HomeMy WebLinkAbout21-2579City of Zephyrhills 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 11111,11IIIIII I III IIIIF F ' 111 11 11 11 T-ITITE447, IT, 1 -7 M-no N BNR-002679-2021 Issue Date: 08/24/2021 Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. IQ Lt4- z-- CONTRACTOR SIGNATURE PE IT OFFICE[) PASCO COUNTY, FLORIDA Permit No. 1 Date Perm", L�� Builder Name/Owner Name K) Control # County Parcel No. Address/Locatlon Classification/Type of l9se TRANSPORTATION IMPACT FEE Rate: Sq. Ft Unit: Exempt oyes No How Determined Impact Fee Amount Zone No, TAZ: Account (056) Single -Family Detached House Amount $ (057) Mobile Home (058) Other Residential 23) Collection Fee Exempt 6 Yes E]14o, How Determined N! 141i, Hili jj%Ej:11ij:!i!4!jjj1j FEE Land Account Land Credit — Land Total Recreation Account _ Recreation Credit — Recreation Total Zone TOTAL AMOUNT $ 7 Exempt 0 Yes No How Determined Land Account Land Credit Land Tote . I Facility Account _ Facility Credit Facility Total Exempt [I Yes No How Determined Total Amount RESOURCE TOTAL AMOUNT ERU Checked By ..UIT4 I ir F I Ili W _SATE ­_— RECEIVE—D—B—Y-- RECEIPT NO, —DATE BY �ITY of Z-ephyrhilis Permit Application Building Department Fax-813-780-0021 Date Received 'e Owner's Name Owner's Address Fee Simple Titleholder Name Fee Simple Titleholder Address �01`113 Contact for Perm Owner Phone Number 3� Owner Phone Number Owner Phone Number JOB ADDRESS :P AL -SUBDIVISION LOT PARCEL ID# 0 13o - o a Is 0/40 WORK PROPOSED NIWCONSTR ADDIALT (OBTAINED FROM �FROPERTY TAX NOTICE) PROPOSED USE • INSTALL E REPAIR SIGN DEMOLISH SFR TYPE OF CONSTRUCTION COMM OTHER BLOCK FRAME STEEL DESCRIPTION OF WORK BUILDING SIZE SQ FOOT =ELECTRICAL =PLUMBING =MECHANICAL = GAS FINISHED FLOOR ELEVATION %�G E Ef HEIGHT VVALUATION IA I I I A ALUATION OF TOTAL CONSTRUCTION AMP SERVICE PROGRESS ENERGY W.R.E.C. VALUATION OF MECHANICAL INSTALLATION SPECIALTY = OTHER FLOOD ZONE AREA DYES grr K01 BUILDER SIGNATURE COMPANY REGISTERED Address Y/ N® FE CURREN Y/N ELECTRICIAN License C SIGNATURE COMPANY I Address REGISTERED Y/ N FEE CURREN Y N PLUMBER License 3 SIGNATURE COMPANY Address REGISTERED Y/N FEE CURR N /N MECHANICAL Licenser# SIGNATURE COMPANY Address C-� REGISTERED VN FEE CURREN Y/N OTHER License # SIGNATURE COMPANY REG[ TERED Y/ Address III I I I I if "I, . I I I I I I I I I I I I II Attach I I I I I I I IRESIDENTIAL License # IIII (2) Plot Plans; (2) sets Of Building Plans; (;I) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, construction Plans, Stormwater plans W/ Slit Fence installed, Sanitary Facilities& I dumpster; Site Work Permit for subdivisions/large projects ec COMMERCIAL Attach (2) complete sets of Building Plans Plus a Life Safety Page; (1) set of Energy Forms. R-O-W permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, StOrMwater Plans W/ Slit Fence installed, Sanitary Facilities & I dumOster. Site Work Permit for all new projects. All commercial SIGN PERMIT Attach (2) sets of Engineered Plans. lal requirements must. ""PROPERTY SURVEY required for all NEW construction, meet compliance Directions: ruction, Fill out application completely. Owner & Contractor sign back of application, notarized If over s2soo, , Notice Of Commencement is required. (A/C upgrades over $7500) Agent (for the contractor) 01 Power of Attorney (for the owner) Would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING Se Reroofs if shingles ( OPY Of contract required) Sewers Servi0ce Upgrades A/c Fences (Plot/Survey/Footage), Driveways -Not Over Counter if on public roadways_needs ROW 4OT|CEDFDEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" whiohmay bemore restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. JNL|CENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a-contnactor or ,ontractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the ,ontraotor is not licensed as. required by |avv, both the owner and contractor nr ay be cited for a misdemeanor violation inder state |ovv. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the ,ntended work, they are advised to contact the Pasco County Building Inspection Division —Licensing. Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or oontrautore, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the oontraotor, that may be an indication that heia notpropor|y]ioanaed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES ' : The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing bui|dinge, or expansion of existing Uuild|ngs, as specified in Pasco County Ordinance number 89-07 and 90'07, as amended. The undersigned also 4ndeCstando, that such fees, as may be due, will be identified at the time of permitting. It is further Understood that Transportation Impact Foee*and Resource Recovery Fees must be paid prior to receiving a "certificate of ocnupency" or final power release, If the project does not involve a certificate of occupancy or final power. release, the fees must be paid prior to permit issuance. Furthermore. if Pasco CountyVVaterlSevver Impact fees are due, they must'be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713.Florida Statutes, om amended): |fvaluation ofwork ia$2'GDO.ODormore, I certify that l, the epp|icant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that 1,have obtained a copy of the above described document and promise in good faith to deliver ittnthe "ovvner"prior tocommencement, CONTRACTOR'S/OWNER'S AFFIDAVIT: { certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application in hereby made to obtain a permit to do work and installation an indicated. | certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all }smva regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. | also certify that } understand that the regulations of other government agencies may apply to the intended vvorh' and that it is myresponsibility toidentify what actions | must take tobeincompliance. Such agencies include, but are not limited to: - Department ofEnvironmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lando. VVeter8W8atevvoterTraatnnent. - Southwest Florida Water Management District -Wells', Cypress Bayhaodm' VVet|iand Areas, Altering Watercourses. - Army Corps ofEngineers-GeevvaUs,Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Aoenc*-Aobeatoaabatement, - Federal Aviation Authoritv-RUOvvayo. | understand that the following reatr|ot|one'app\ytotbe use of fill: ' Use offill (anot allowed |nFlood Zone "V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A/'^ it is understood that a drainage p|eO addressing a "compensating vol.ume"wiU be submitted at time ofpermitting which is prepared by a professional engineer licensed bythe State of Florida. - If the fi||'materio| is to be used in Flood Zone "/Y' in connection with a permitted building using stem vva|i construction, | certify that fill will be used only tofill the area within the stem wall, - If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent propertiao, the'owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots \oae than one (1) acre which are elevated byfill, anengineered drainage plan iarequired. If | am the AGENT FOR THE OWNER, | promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. \ understand that a separate permit may be required for electrical work, p|umbing, signs, vve||s' pools, air condition\ng, gas, or other installations not specifically included in the application. A permit issued ohe|| be construed to be e license to proceed with the work and not as authority to violate, oanne|, e(ter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring e correction of errors in plains, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within S[X months of permit \aSU@Dca. Or if work authorized by the permit iasuspended orabandoned for aperiod ofsix (8) months after the time the work iscommenced. An extension may be requeoted, in writing, from the Building Official for a period not to exceed ninety /BO\ days and will demonstrate justifiable cause for the extension. |fwork ceases for ninety (8D) consecutive days, the job is considered abandoned. FLORIDA JURAT (F OWNER OR AGENT CONTRACTOR Subs r! ed nd sworn to (or affiM, d) befor this Subscribed and sworn to (or affirmed) before me this by by Wtfo is/are p or has/have prodbued Who is/are personally known to me or has/have produced as identification. as identification. Public Public Commission No. Commission No. Name ofNotary typed, printed or stamoed Name of Notary typed, printed or stamped FNWAry P0110 State Of FfWda Michelle Moyes �^�s 1����4~�.' � PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 11 BLOCK 10, SILVERADO RANCH SUBDIVISION PHASE 5B AS RECORDED IN PLAT BOOK 81, PAGE(S) 69-73, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table cu7,--#TL--­g--F—R-I-- D I -it. Chord Bearing � Chord � :7C 5.85, Line Table Llna #T7Dire�L.�ngth Ll I S52-OV12-E 1 45.57' ::L2J�1'29'00"W �1472' C� 7 -0 6 ^P, -10, 44 Oc, o 4-1 1� 170 00 PREPARED FOR: U-n-HO BUILDING SETBACKS FRONT: 22' REAR: 13' SIDE: 7,5' SIDE STREET: 22' 1. ELEVATIONS SHOWN ARE PER LOT GRADING PLANS PROVIDED BY THE CLIENT, 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. 00, 00, 41 1b , V O ), tK 00 /0 70 97.4 rV THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT AND IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT A SURVEY THIS IS A PLOT PLAN ONLY FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO289F, DATED SEPTEMBER 26, 2014, AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE PARTIALLY IN ZONE "X" & -AE-. ZONE -X-, AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. ZONE -AE-, DENOTES AREAS DETERMINED TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT TO INUNDATION BY THE 1% ANNUAL CHANCE FLOOD EVEN' BASE FLOOD ELEVATIONS DETERMINED TO BE 92.5% THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF COBBLE BILI55 STREET BEING N52*05'12'W, PER PLAT. (FIELD DATE:) SCALE: 1" = 30 FEET APPROVED BY: --16- 200646 LOT 11 BLOCK 10 JOB NO. — DRAWN BY; RMB A/C S/W 1" 30- CIO GRAPHIC SCALE 0 15 30 V, 4, /p 'S, zop z ON LOT CALCULATIONS LOT = 8,726 SO, FT, LIVING AREA = 2,045 SQ. F1 GARAGE = 454 SQ. FT. ENTRY = 35 SQ. FT. LANAI = 221 SQ. FT. PATIO = 0 SQ. FT DRIVEWAY = 368 SQ. FT. A/C PAD = 12 SQ. FT. WALKWAY = 44 SQ. FT. IMPERVIOUS = 36% = 3179 SQ. FT. SOD = 5,547 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 713 SQ. FT. DRIVE APRON = 66 SQ. FT. PUBLIC S/W = 305 SO, FT. SOD = 342 SQ, FT. TOTALS AREA = 9,439 SQ. FT. DRIVEWAY = 434 SQ. FT, SIDEWALK = 349 SQ. FT. SOD = 5,889 SQ, FT. IMMAR11 BUILDING SETBACK LINE PI PC CENTERLINE PT RIGHT OF WAY LINE RP PRC PROPOSED ELEVATION PCC TYP PROPOSED DRAINAGE FLOW CS (P) CONCRETE (C) PB AIR CONDITIONER PGS SIDEWALK SQ. FT. F.E.M.A. F.I.R.M. NAVID NGVD D&UE D&AE POE PUE A5M I 8& MAPPING INC. CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 3191 MAGUIRE BOULEVARD, SUITE 200 ORLANDO, FLORIDA 32803 (407) 426-7979 WWW.AMERICANSURVEYINGANDMAPPING.COM POINT OF INTERSECTION POINT OF CURVATURE POINT OF TANGENCY RADIUS POINT POINT OF REVERSE CURVATURE POINT OF COMPOUND CURVATURE TYPICAL CONCRETE SLAB PER PLAT CALCULATED PLAT BOOK PAGES SQUARE FEET FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP NORTH AMERICAN VERTICAL DATUM NATIONAL GEODETIC VERTICAL DATUM DRAINAGE & UTILITY EASEMENT DRAINAGE & ACCESS EASEMENT PRIVATE DRAINAGE EASEMENT PUBLIC UTILITY EASEMENT — v C 1 -1 11— — 1. THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OF WAY, RESTRICTIONS OF RECORD WHICH MAY AFFECT THE TITLE OR USE OF THE LAND. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. 3. NOT VALID WITHOUT THE AUTHENTIC ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. jlloo+,111111,111111,�� Digitally signed by James W Boleman 4,11 `v 4 li, DN. -US, st4l.,ina, -AMERICAN SURVEYING & MAPPING, INC,--Jamel W email=jboleman@asmcorporate.com FOR THE Date: 2021.07,08 10.14-19 -000' Adobe Acrobat —Imm 11,0.23 FIRM JAMES W. BOLEMAN PSM# 6485 DATE 0 F BUILDING ZEIPHYRHILLS DEPARTMENT "NOTICE" OF ADDITION OR CORRECTION ADDRESS DATE PERMIT# THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted It is unlawful for any Carpenter, Contractor, Builder, or other persons, to cover or cause to be covered, any part of the work with flooring, lath, earth or other material, until the proper inspector has had ample time to approve the installation. OFFICE HOURS 8:00 AM - 4:30 PM MON.-FRI. AFTER CORRECTIONS ARE MADE CALL 780-0020 FOR7E-IRS CTION INSPECTOR 101;11,w "'�Inw N.-ToRTMIR irmn# I Permit No. Parcel ID Na State of Florida County of THE UNDERSIGNED hereby gives notice that improvement will be made to certain rear property, and In accordance with Chapter 713, Florida Statutes, the following information is provided In this. Notice of Commencement1. - r Description of Property: Paropi Identification No. I elli 10.11 Street Address: "or 0 2. General Description Of Improvement de nce 3. Owner Information or Lessee information if the Lessee contracted for the improvement: Address --T-a�.�33�637 -EL-- interest in Property: CIty State Name of Fee Simple Titleholder: (If different from Owner listed above) 4. Contractor: City State t ame 12602 TRItzrr)m nrh/p Address city 7 FL Contractor's Telephone No,: State 5. surety: N/A Name Address City State Amount of Bond: . 11ii Telephone No.: 6. Lender: N/A Name Address �Y City State Telephone No,: 7. Persons within the State of Florida designated by the owner upon Mom notices or other documents Section 713.13(1)(a)(7), Florlde,atatutes: may be served as provided by David GUHR Name Address Tama33637 FL Telephone Number of Designated Person: 83-740-9720 1 city State 8, In addition to himself, the owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1.)(b), Florida Statutes, Telephone Number of Person or Entity Designated by Owner: g. Expiration date of Notice Of Commencement (the expiration date may not be before the completion of construction and final payment to the contractor, but will be one year from the date of recording unless a different date Is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTI CRNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing 6"—) f commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO 71- atuQ 11 If Owner or Lessee, or �0,n,,s or Lessee's Authorized Officer /Director/Pai",ner/Manager Signatory's Title/Office The foregoing instrument was acknowledged before me this 12—day of 20 4/ by as (type of authority, e.g., officer, trustee,\attomey in fact) for D,R Horton, Inr- (name ofnartv on behalf nfwhnmingntmel+wasexecuted). Personally Known R OR Produced Identification M Notary SignaturesX", Type of identification Produced Name (Print) 4!`f y ON Notary Public State of Fiorida Michelle Mayes MY Commission HH 066897 OF ft Expires 12121/2024 wpdatalbcs/noticecorr,mence,-nent—pcO53048 ►ingle Family Dwelling I F,FE, shall bea mintmunn of'8" above the road elevation and an en(yineered site plan, tn' 1 Lots shall be graded to cotuply with R401,3 of" the Conipaction test required i 1'24" or rnore of fill dir-t is brought in at any one place, 4, le in survey reqUired bel'ore pouring concrete, Driveways reqUire a R,().W, use pert'nit, All 4 sides ol"driveway thrU the. sirtcavalk shall have expansion mateiial, 6, All setbacks shall be met, 7. All property triarkers shall be uncovered and inarked at tirne ot" first inspection, 8, All AD -A, requirenients sliall be rnet, It. No electric, plurnbing., triechanical, or frarning shall be covered without an inspection and approval first, 10, All Giarages shall cornply with section R302,6 of the F',B,(" . (Fire Separation), It, Appliances shall riot be installed in as location wbere SU[�jsCt to mectranical dainage unless protected by approved barders, M303.4 ofthe F13,C 12, Water heaters shall comply with section 1-1607.3 of tfiie 13, Foundation supports for A units sliall be raised at least 3" above finished grade, M 1308_1 14, Return air in all bedroorns, F,B,(', 1\1 1620A 15, Si'noke detectors are to be installed in accordance with 1 313,1 ofthe F,B,(', 16, All glazirig requirements are to be fin accordance %vith R 108.4 of the t.B,C', 17, All nreans of egress are to be in accordance with R311 of the F,B,(", 18, "Green gyTisurn board" shall not be used as as backer in showers or tubs, 1 702,4,2 F , B, 19Conibinal i on -type A 1F('1 breakers are reqUffed at all locations requiri.ng an AFCI tyT,)e breaker, 2(Y Carbon rrionoxide alarins a,vfll lie required in new construction that uses fossil-bumirig heating or apphances or an attached garage, They sliall be installed in accordance with the FRC. 2 1. All plumbing, mechanical, and electrical shall be separate from unit tO Ullit This includes all underground plumbing and electric, 22, All 2016 N,E,(', Codes will be enforced, 23. Tamper- Resistant Receptacles in accordance with 406,11 of the 2016 N,k`,C 24, In accordance with the L,and I)evelopment (;cede., lots shall lie sodded before final at least 10 feet around the WUCRIR�, 25, R403,5,3Hot water pipe insulation Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping 1, inch (1 9e 1 Barra) and larger in nominal diarneter, Piping serving more than one dwelling unit, Piping located outside the conditioned space, Piping from the water heater to a distribution manifold. Piping located under a floor slab. Buried in piping, Supply and return piping in recirCUlation systems other than demand recirculation systems 25. Blower door test shall be provided before C.O. 26 4 cov�r 'the ener, Lrgyj� cachl shall be with EC-r_rnit (q all lintes. 2Z . I , erinit befime finaL 28. this ermit. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6' Edition R.O.W.-Right of Way A.D.A.- Americans with Disabilities Act N.E.C.- National Electric Code (2016)