Loading...
HomeMy WebLinkAbout21-2580City of Zephyrhilis 5335 Eighth Street Ulllalllsl'=� M� M!"I'll Zephyrhills, FL 33542 BNR-002580-2021 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 08/31/2021 35 25 21 0170 00900 0160 '01 077 p ,g g Name: D R HORTON -Permit Type: Building New (Residential) ORIZEN a= M.; CONSTRUCT SINGLE FAMILY 3,153 SO FT zI School Impact Fee Driveway Fee 3/4 Water Meter Fee (Calc) Mechanical Permit Fee Building Permit Fee Plumbing Plan Review Fee Public Safety Impact Fee -Police Building Plan Review Fee Electrical Permit Fee Sewer Connection Residential Fee Transportation Impact Fee - City Class of Work: SFR Construct Building Valuation: $115,000.00 Electrical Valuation: $8,000,00 Mechanical Valuation: $8,000.00 Plumbing Valuation: $9,500.00 Total Valuation: $140,500.00 Total Fees: $18,494.50 Amount Paid: $18,494.50 Date Paid: 8/31/2021 2:07:17PM $8,328.00 Address Fee $30.00 $45.00 Plumbing Permit Fee $87.50 $473,78 Mechanical Plan Review Fee $40.00 $80,00 Irrigation 3/4 Meter (Cale) $473.78 $605.00 Public Safety Impact Fee -Admin $26.35 $4175 Transportation Impact Fee $3,595.68 $254.00 SIF 1 percent Fee $83.28 $302.50 Electrical Plan Review Fee $40.00 $80,00 Park Impact Fee - Single Family/Townhome $769.56 $2,090.00 Water Connection Residential Fee $1,010.00 $36.32 J 0111IME11SI Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SJGNATNRE--_ PE IT OFFICE -1 .'�ERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER is I i + ' • i ii � i •♦ i ii Permit No. Parcel ID No �, _ ti +; 1�® OO C)lLco NOTICE OF COMMENCEMENT State of Florida County of__I as THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement 1. DescriptonofProperty: ParcelldentificationNc. Street Address: 3 - 2. General Description of Improvement New Sinale F21 111Y RESidenCe 3. Owner Information or Lessee information if the Lessee contracted for the improvement: D.R HOriOn inn Name T�I�t._nm L�rI Tgmnp ® 33637 -EL— Interest City State Address Interest in Property: FeQ�Ii1ll71e Name of Fee Simple Titleholder. (If diffarentfram Owner fisted above) Address City State 4. Contractor: Address Contractor's Telephone No.: 5. Surety: TaL�p�— 33,6E FL City State Name Address C4ty Amount of Bond: $__ (�%A Telephone No.: 6. Lender: N/A Name Address Lender's Telephone No.: City State State 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713,13(1)(a)(7), Florida Statutes: David G ide Name 1 602 Telt�com ?rjy� _ Tam 33637 FL -- Address City State Telephone Number of Designated Person: 6� 3-74Q-9720 B. In addition to himself, the owner designates ._. N/A of to receive a copy of the Lienor's Notice as provided In Section 713.13(1.)(b), Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement (the expiration date may not be before the completion of construction and final payment to the contractor, but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713,13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that 1 have read the foregoing of my knowledge and belief, once f commencement and that the facts stated therein are true to the best STATE OF FLORIDA COUNTY OF PASCO Sig tore of Owner or Lessee, or Owners or Lessee's Authorized Officer/Director/Partner/Manager Assistant SeQretarv/D.R. Horton Inc Signatory's Title/Office The foregoing instrument was acknowledged before me this day of ' 4 ' 20 Lj by t 00 �3 -j as (type of authority, e.g., officer,, trustee ttorney in fact) for D.R. Horton. Inc (name of p y on b half of whom inorument was executed). Personally Known 5& OR Produced Identification El Notary Signaturp -" 1 i---Z/� Type of Identification Produced Name (Print) v Notary Public State of Florida Michelle Moyes My Commission HH OWS97 cra Expires 12/21/2024 wpd ata/bcs/noti cecommencement_pc0S3048 v PASCO COUNTY9 FLORIDA Permit No, 11-+ M Builder Name/Owner Name Control# County Parcel No, UbDiv: Address/Location �'�769, Rate: Sq. Ft Unit: -3 Exempt LJ Yes ] No How Determined lMn,qct F-4— f . - I 1z _Y19 " Zone No. . TAZ: -- F8CH-0-0-L-1M—PACT —FEE Account (056) Single-Famiiy Detached House Amount ' $ (067) Mobile Home (058) Other Residential 23) Collection Fee Exempt Yes []NO How Determined E Land Account Land Credit _ Lend Total Recreation Account � Recreation Credit _ Recreation Total Zone - - I TOTAL AMOUNT Exempt 0 Yes [] No How Determined Lid Y FEE Land Account Land Credit Land Tota I I Facility Account Facility Credit ------ Facility Total Exempt El Yes [] No How Determined � Total Amount TOTAL AMOUNT ERU Prepared Ely 4� ]C�hecked Esi RECEIPT NO. -.DATE ---- � BY 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Owner's Address 112602 Telecom Drive, Tampa, FL 33637 j Owner Phone Number Fee Simple Titleholder Name I L54ni Owner Phone Number Fee Simple Titleholder Address I I JOB ADDRESS Aprya�#' / CJ'&.Q 'n LOT # SUBDIVISION lAbbott Park (Zephyr Lakes) PARCEL to# 07/' 47/ 0740 #tAOF400 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT INSTALL E REPAIR PROPOSED USE SFR 0 Comm TYPE OF CONSTRUCTION BLOCK FRAME BUILDING SIZE i SQ FO 1L]C3E1CJE It M�ILIC]CiLIC_t IL 1E BUILDING ELECTRICAL i$ PLUMBING $ MECHANICAL $ = GAS � ROOFING SIGN DEMOLISH OTHER STEEL rJP HEIGHT 7 lc_x YLALAL x7x-x it X-IL JE it WALAEXIE WVWILAL VALUATION OF TOTAL CONSTRUCTION AMP SERVICE PROGRESS ENERGY W.R.E.C. is VALUATION OF MECHANICAL INSTALLATION SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO f-4*4 BUILDER COMPANY Inc SIGNATURE L REGISTERED Y/N FEE CURREN Y/N Address 112602 Telecom Drive, Tampa FL 33637 License # I CBC039062 ELECTRICIAN 416 COMPANY Strada Electric SIGNATURE 19 REGISTERED Y/N FEE CURREN Y /N Address 3400 St Johnskwy, Sanford, FL 32771 License# EC13003715 PLUMBER COMPANY Northwest Plumbing SIGNATURE REGISTERED Y/N FEE CURREN Address 6310 Mableton Pkwy, St 1000, Mableton, GA 30126 License # I CFC1427137 MECHANICAL A91\ COMPANY Progressive Air Systems SIGNATURE REGISTERED Y/N FEE CURREN Address 7130 Meighan Ct, New Port Richey, FL 34652 License #F CAC033669 OTHER COMPANY Brad McDonald Roofing — I SIGNATURE REGISTERED Y/N J FEE CURREN I Y N__J Address 17143 SR 54, New Port Richey, FL 34653 License # I CC1325833 RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & I dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW K3 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 SHEET 2 Building Department Date Received Phone Contact for Permittiing dsbeauchaine@drhorton cola �€ _ .€ te a wwww' 'W'T' Owner's Name DR ortnn Inv. Owner Phone Number 113-549-1068 Owner's Address 1 12602 Telecom Drive, Tampa, FL 33637 Owner Phone Number Fee Simple Titleholder Name �® Owner Phone Number Fee Simple Titleholder Address I I LOT # JOB ADDRESS SUBDIVISION Abbott Park�(Zephyr Lakes) PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN 0 DEMOLISH e INSTALL REPAIR 8 PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME 0 STEEL DESCRIPTION OF WORK See Sheet I BUILDING SIZE SQ FOOTAGE, JLEIhis info HEIGHT See N/A BUILDING L N/A VALUATION OF TOTAL CONSTRUCTION Sheet I for all Values NELECTRICAL /� $ AMP SERVICE PROGRESS ENERGY W.R.E.C, N%A PLUMBING $ N/A MECHANICAL VALUATION OF MECHANICAL INSTALLATION $ =GAS ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS See Sheet I for this info FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE L REGISTERED Y / N FEE CURREN Y / N Address License # ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y I N Address License # I PLUMBER COMPANY Lawn Medic Landscaping & Irrigation SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address 4827 Beauchamp Rd, Plant City, FL 33563 1 SCC131152084 NA COMPANY SIGNATURE REGISTERED Y % N FEE CURREN Y ( N Address OTHER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # RESIDENTIAL Attach (2) Plat Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required, (A/C upgrades over $7500) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (PloUSurvey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City ofZephyrh|Ua Permit Application Fux-813-780-0021 Building Department NOTICE opDEED RESTRICTIONS: The restrictions" which may be more restrictive than County |ah The undersigned assumes responsibilityapplicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: nthe owner has hired acontractor or contractors to undertake work, they may borequired to be licensed in accordance with state and local regulations. If the contractor is not licensed aorequired bylaw, both the owner and contractor may becited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as towhat licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8008. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions ofthe "contractor Block" ofthiu application for which they will be responsible. If you, an the owner sign as the oontractur, that may be an indication that he is not properly ||onnaod and is not entitled topermitting privileges inPasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing bui|uinga, as specified in Pasco County Ordinance numun,ns-o7 and 90-07. as amended, The undersigned also unuorstanus, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must uvpaid prior m receiving a "certificate vfoccupancy" orfinal power release, |fthe project does not involve ocertificate moccupancy orfinal power release, the fees must onpaid prior mpermit issuance, Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permiti in accordancewith applicable Pasco County ordinances CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction, I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management Distdnt-VVe||s, Cypress Buyheeda, VVat|mnd Areaa, Altering Watercourses. - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-VVo||s, Wastewater Treatment, Septic Tanks. - UGEnvironmental Protection Agency -Asbestos abatement. - Federal Aviation Authority -Runways. | understand that the following restrictions apply to the use of fill: - Use nffill isnot allowed inFlood Zone Wrunless expressly permitted. ' If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing u ^compenaatinQ volume" will be submitted at time of permitting which is prepared by professional engineer licensed bythe State ofFlorida. - If the fill material is to be used in Flood Zone ^A" in connection with o permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent propertieo, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. |f|amthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth inthis affidavit prior to commencing construction. | understand that aseparate permit may ue required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by x permit| commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six ( after the time the work is commenced. An extension may be requosted, in writing, from the Building Official for eperiod not to exceed ninety (90) days and will demonstrate justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job is considered abandoned, WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT 11,11, FLORIDA JURAT (F.S. 11 7Z)F OWNER OR AGENT CONTRACTOR 4 r' d and sworn to (or affirmed) before me this Subscribed and sworn to (or affirmed) before me this 0, �is are personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. fl'Q, IA-- Notary Public C 0 4M, s S_ko n N o. Name of Notary typed, printed or stamped Commission Name of Notary typed, printed or stamped 1, l".RF, shall be a mininnurn of'8` above the road elevation and an engineered sitc plan, 2, L,ots shall be graded to comply with 1 401,3 ofthe. F,B,C, 3, Compaction test required if'24" or swore of fill dirt is brOLIght iin at any one place, 4'Fie in survey required before pouring concrete, Driveways require as R-O.W, use perniit. All 4 sides of driveway thru the sidewalk shall have expansion rnaterial. 6, All setbacks shall be met, T All property markers shall be Llocovered and marked at time of first inspection, 8, All A,D,A, requirenients shall be inet, 9, No electric, plumbing, mechanical, or frarning shall be covered without an inspection and approval first, 10, All Garages shall comply with section R302,6 of the F,B,(', (Fire Separation), I 1. Appliances shall not be installed in a location where sulvect to inechanical darnage unless protected by approved barriers, M303A ofthe F,B,C' 12, Water heaters shall cornply Nvith section 1`16073 ofthe F,B,(', 11 Foundatior.i supports tbr A'C units shall be raised at least 3" above finished grade. M 1308,1 14, Return air iri all bedroorns, FRC. INT 1620A 15, Smoke detectors are to be installed in accordance with R3 13,1 ofthe F.B.C', 16, All glazing requirements are to be in accordance with 1308.4 of the 1`,B,C', 17, All means ofegress are to be in accordance %vitli R311 of the FRC, 18, "Green gypsurn board" shall riot be used as as backer in showers or, tubs, R702,4.2 F,B,(', 19, Combiriation-type AFCI breakers are required at all locations requiring an AR " I type breaker, 20, ("arbon tno-noxide alarms will be required in new constructiori that LISes fOSSH-bunrltigheatrrig or appliances or an attached garage, T'hey shall be installed in accordance with the f,`.B C, 21, All plumbing, mechanical, and electrical shall be separate frOM U111t top 1,111il, "T'his includes all under -ground pluTribing and electric, 22, All 2016 NEC, Codes will be enforced 23, Tamper- Resistant Receptacles in accordance with 406,11 of the 2016 N,E,(' 24, In accordance with the Land Development Code, lots steal I be sodded be for final at least 10 feet around the structure, 25, R403.5,3Hot water pipe insulation Insulation for hot water pipe with a miniMLIM thermal resistance (R value) of R-3 shall be applied to the following: Piping --,/, inch (19,1 rnrn) and larger in norninal diarneter, Piping serving more than one dwelling unit, Piping located outside the conditioned space. Piping from the water heater to a distribution manifold, Piping located under a floor slab. Buried in piping, Supply and return piping in recirculation systems other than derriand recirculation systems, 25. Blower door test shall be provided before C.O. 2& A cfjwjg oL-thq enieur& shall be with &yini( at all tinnes. 2 7 1 erinit be ime inaL 24. this erniht F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6b Edition R.O.W.-Right of Way A.D.A.® Americans with Disabilities Act N.E.C.® National Electric Code (2016) PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 16, BLOCK 9, ZEPHYR LAKES SUBDIVISION PHASE 2C AS RECORDED IN PLAT BOOK 84, PAGE(S) 91-93, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. a F� z 1"=30' GRAPHIC SCALE 0 15 30 PC LOT 15 BLOCK 9 I $ w� S89'S0'S9"EA 115.00' 03 r W nl z I Z = CL w 0 I29.5" 5' D&AE O 6.7 48.9' zjs '. 00 N 42.6R7>'prn amG3W ¢ C LfL) C) 0 inm naCm LtJ ' Q° F�� .-SN?. <N Y Y _jf 00 D.z M a> E O h¢ "a �v W N.. I.".: 40.T 0 0 Nan. 40 C) ---25.6' 5' D&AE 48.8' �! -'�Z ups _ — se9o00aa 25. .0' 50 a n PLAT BOUNDARY qry� � I ZEPHYRHILLS COLONY COMPANY -----PCPi�— PLAT BOUNDARY PLAT BOOK 1, PAGE 55 PREPARED FOR: $ " tL— BUILDING SETBACKS FRONT: 20'* GARAGE: 25' REAR: 15'* SIDE: 5' SIDE STREET: 15' LEGEND: * STAGGERED FRONT GARAGE SETBACK = 25' FRONT THEN 27' FRONT, ON 27' FRONT— REAR SETBACK IS REDUCED TO 13' NOTES: 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED ON THE APPROVED ENGINEERING PLANS PREPARED BY HAMILTON ENGINEERING & SURVEYING INC. 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. 3. FOR ALL LOTS WHERE SIDE —YARD SETBACKS ARE LESS THAN 7.50 FEET, A MINIMUM 5.00 FOOT WIDE DRAINAGE & ACCESS EASEMENT IS HEREBY CREATED ON ALL SIDE LOT LINES, UNLESS OTHERWISE NOTED. THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY CONSTRUCTION. THIS IS NOT A SURVEY THIS IS A PLOT PLAN ONLY FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO293F, DATED 09/26/2014, AND FOUND THE SUBJECT PROPERT, APPEARS TO LIE IN ZONE "X", AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATON. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF SAIL CLOVER LANE BEING NOO'09'32"E, PER PLAT. (FIELD DATE:) REVISED: SCALE: 1" = 30 FEET APPROVED BY: JB JOB NO. 210506 LOT 16, BLOCK 9 DRAWN BY; DSB ON LOT CALCULATIONS LOT = 5,750 SQ. FT. LIVING AREA = 1,104 SQ. FT. GARAGE = 437 SQ. FT. ENTRY = 43 SQ. FT. LANAI = 0 SQ. FT. PATIO = 80 SO. FT. DRIVEWAY = 408 SQ. FT. A/C PAD = 12 SQ. FT. WALKWAY = 30 SQ. FT. IMPERVIOUS = 37% = 2114 SQ. FT. SOD = 3,636 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 650 SQ. FT. DRIVE APRON = 152 SQ. FT, PUBLIC S/W = 250 SO. FT. SOD = 248 SQ. FT. TOTALS AREA = 6,400 SQ. FT. DRIVEWAY = 560 SQ. FT. SIDEWALK = 280 SQ. FT. SOD = 3,884 SQ. FT, — — — BUILDING SETBACK LINE CENTERLINE — — — RIGHT OF WAY LINE PROPOSED ELEVATION PROPOSED DRAINAGE FLOW CONCRETE A/C AIR CONDITIONER S/W SIDEWALK PI POINT OF INTERSECTION PC POINT OF CURVATURE PT POINT OF TANGENCY RP RADIUS POINT PRC POINT OF REVERSE CURVATURE PCP PERMANENT CONTROL POINT TYP TYPICAL CS CONCRETE SLAB (P) PER PLAT (C) CALCULATED PB PLAT BOOK PGS PAGES SQ. FT. SQUARE FEET F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM D&UE DRAINAGE & UTILITY EASEMENT D&AE DRAINAGE & ACCESS EASEMENT DE PUBLIC DRAINAGE EASEMENT LIE PUBLIC UTILITY EASEMENT LWE LANDSCAPE/WALL EASEMENT (PRIVATE) 1. THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OF WAY, RESTRICTIONS OF RECORD WHICH MAY AFFECT THE TITLE OR USE OF THE LAND. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. 3. NOT VALID WITHOUT THE AUTHENTIC ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. \�`�p'N�IIII�I Mp�4ip� & MAPPING Digitally signed by James W Boleman DN:< US st Florda 1-0,lando, a 6 * ,» I �"-AMERICAN SURVEYING& MAPPING INC., cn—James W Boleman, s email Jb._I an(:asmcorporatecom FOR Date: 2021.070¢ 10:02:49 T4'00' THE 3191 Maguire Blvd, Suitt, 200, Orlando, FL 32803 °mrre,m"�w AdobeAu IaM dsq,:1L0.23 FIRM 407 a25i;4nri JAMES W. BOLEMAN PSM# 6485 DATE tTRRPTlP'Fi K1i2lAI'tlt'aitlllYir4t1t{iilFiYl ESIfF{i PYY