HomeMy WebLinkAbout21-2594- ------- --
�
Cpit y of Zephyrhills "I", I
101
NOR,
5335 Eighth Street Msmiawimm
Zephyrhills, FL 33542 BAR-002694-2021
Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 08/26/2021
11 26 21 0010 11200 0180
(Residential).
Address: 5604 18Th St
ZEPHYRHILLS, FL 33542
Phone: (813) 783-4202
Class of Work: Add/Alter Residential
Building Valuation: $7,300.00
Electrical Valuation: $0.00
Mechanical Valuation: $0,00
Plumbing Valuation: $0.00
Total Valuation: $7,300.00
Total Fees: $114.75
Amount Paid: $114,75
Date Paid: 8/2612021 10:11:21AM
5604 18Th Street
SOLUTION
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CQNTRACj)R SIGNATURE;- PEfAIT OFFICE[)
PERMII'EXPIR IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
MICHAEL CACIOPPA
5604 18"STREET ZEPHYRHILLS, FL 33542
SINGLE - STORY CMU HOME ON CONCRETE FOUNDATION WITH A SHINGLE ROOF
(5) MODEL 300 PUSH PIERS THREE CONCRETE CUTS INCLUDED
m
ALL WO HALL 00 "a MPLYWITH PR-VAUNG
CODES
NATIONk
X
AND
ORDINANCE ' s , 1YRHILLS
R CE V i E: ",1V RAT E
c,
813-780-0020
City of Zephyrhills Permit Application
Building Department
Fax-813-780-0021
alr. �
arm
Owner's Name
r.'
owner Phone Number
Ownees Address
Owner Phone Number
Fee Simple Titleholder Name
Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS
LOT #
SUBDIVISION
i. 1+
-(OOTAINED
M►
FROM PROPERTY TAX NOTICE)
WORK PROPOSED
NEW CONSTR ADD(ALT
INSTALL
REPAIR
PROPOSED USE
SFR
COMM
TYPE OF CONSTRUCTION
BLOCK
FRAME
DESCRIPTION OF WORK
_ 4 t1
-;:- 'OUS A
SIGN = DEMOLISH
OTHER
STEEL
BUILDING SIDE [® ^� SO FOOTAGE HEIGHT if I ��f t
=BUILDING $ U VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C.
PLUMBING
=MECHANICAL is VALUATION OF MECHANICAL INSTALLATION t
t
GAS ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY 4 { ®�� �i�� S0CA��'A�l st 7 .
SIGNATURE REGISTERED Y(N FEE CURREN Y/'N i
Address — 7B ! rr License #
--
ELECTRICIAN � COMPANY .m
SIGNATURE REGISTERED Y (N FEECURREN Y 1 N
Address License #
PLUMBER COMPANY
SIGNATURE REGISTERED Y / N FEECURREN Y / N
Address License #
MECHANICAL COMPANY F__�
SIGNATURE REGISTERED L. Y / N FEE CURREN Y ( N
Address License #
OTHERE=== COMPANY
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
Address License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster, Site Work Permit for subdivisionsllarge projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w( Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
—'PROPERTY SURVEY required for all NEW construction,
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required, (A/C upgrades over $7500)
— Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
lye ,
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009,
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not property licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner' prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Welland Areas and Environmentally Sensitive
Lands, Water[Wastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways,
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority- Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required,
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
I MINA 01tallITA LOV's 101,14 1 J, I =1 T41*1 � . . I win I ivolill w 11:4,11 Rik &XVI.-Ifil I iLks I I I Y-1111 L, I LCLIFiaii 'walmmuoll '[01114 -0-
FLORIDAJURAT (F.S. 117.03) A
OWNER OR AGENT Ad
So scri ad and sworn to r affirn ed e ore me th
7 -1 by If #_ &,Lzeoiao
Who is are personally known to me or has/hava p oduced
DeviomAt ILw as identification.
N.ta,Public
Commission No.
Name of Notary typed ,printed or stamped
=STEVEN BRUCE GAYHEART
State Q Florida
Notary Public _,te
Commission GG 353983
MY Comm. Expires ,,,! 11, 2023
Bonded through Natioral' Notary Assn,
3
me or has/have produedn
as identification.
Commission No. W I 1 7 e1%
Name tofqrklbt- Notary fp"111. or stamped
oapP STEVEN BRiCE GAYHEART
Notary Public - State of Florida
Commission # GG 353983
My Comm. Expires Jul 11, 2023
Bonded through National Notary Assn.
I=.
Stable Foundation Solutions, Inc.
23335 NW CR 236 - Suite 30 Stable Foundation
High Springs, FL 32643 Solutions, Inc.
www.stablefoundationsinc.com
866.282.5736 '11 11
PROPOSAI. DATE: 07/22/2021
SUBMITTUD TO: MICHAEL CACICIPPA
ADDRESS: 5604 1 8th St.
Z EPHY RH IL L S F L 33 54 2
ist
Representative: BOB BREWSTER
Cell: 813-344-II�III III
8971
lefoundationsinc.com
Total Contract Price $ 7,300=
Deposit Required 30% $ 2,300 00
Due Upon Completion $5,000.00
Owner SISnature
Signature
Date- 07/22/2021
Stable Found I tion Inc gyres tative
Signature X Date-, 07/22/2021
Date: 7/22/2021
Job: Michael Cacioppa
Location: 5604 18" St.
Zephyrhills, FL 33542
PUSH PIER DESIGN ANALYSIS
The load requirements for the piers designed to assist in supporting the identified areas of the subject residence
were determined. The selected pier locations and the specific piling are identified on the Pier Identification and
Location Plan attached. The calculated total loads on the piers in the specific location, including both dead and
live loads are documented in the attached table which is designated as Attachment "A". Based on the total load
requirements for each of these piers, the push pier driver is to be employed. The push pier driver should be
employed with a calculated load of12,000—,—_ lbs., which will provide pier capacity, including the 2 to I safety
factor, of 24 000 _ lbs. which is greater than the maximum calculated total load of _12, 000 _ lbs. which
occurs on the pier identified as no. I . Based on this analysis, the use of the push pier driver for the push piers
with a specific Load of 24,000 lbs. and a minimum depth of 15' is approved and certified as meeting all the
requirements of the Florida Building Code 2020 71" Edition, and good engineering practice. This is not to be the
primary support structure, but a supplement support to assist in support of the weight of the structure, which will
reduce the total pressure on the existing soils. After completion of installation, Cool and Cobb Engineering
Company shall be supplied with a drilling log of the location and depths of each pier installed so they can evaluate
the installation and prepare the "As Built" drawings.
General Notes:
I. All piers to be installed in accordance with ICC ES AC 358
2. A log of each pier to be kept by Contractor noting depth for each pile.
3. Piers installed less than 48" apart are to be battered 10' away from each other.
4. All pile calculations are based on a maximum spacing of 8'-0".
5. This design is based on the loads of the structure placed on the shallow soils under the structure.
6. No deep soils geotechnical testing information was provided for this design.
7. This design does not address any possible sink hole activity as defined in Florida Statute § 627.706.
7/22/2021
Kenneth F Wheeler, P.E.
State of Florida
yPro,,essional Engineer No. 60417
203 W. Main St.
Avon Park, FL 33825
Office: (863) 657-2323
Fax: (863) 657-2324
Contractor: Stable Foundation Solutions
MICHAEL CACIOPPA
5604 181h STREET ZEPHYRHILLS, FL 33542
SINGLE — STORY CMU HOME ON CONCRETE FOUNDATION WITH A SHINGLE ROOF
(5) MODEL 300 PUSH PIERS THREE CONCRETE CUTS INCLUDED
Cool and Cobb Engineering Co_
7/22(2021 w 203 W. Main St.
Kenneth F Wheeler, P.E. Avon Park, FL 33825
PE# 60417
Cool • i Cobb
Date: 7/22/2021
Job: Michael Cacioppa
Location: 5604 18th St
Zephyrhills, FL 33542
Attachment "A"
Total Load on Pile (Live Load F Dead Load)
PILE NO. TOTAL CALCULATE LOAD
1 12,000 Ibs
2 12,000 Ibs
3 12,000 Ibs
4 12,000 Ibs
5 12,000 Ibs
Maximum Total Load on Pile: 12,000 Ibs
4
Cool and Cobb Engineering Co.
7/22/2021 203 W. Main St.
Kenneth F Wheeler, P.E. Avon Park, FL 33825
PE# 60417
M
MANUFACTURING
TMG Manufacturing offers 4 different foundation brackets designed to meet t
needs of any foundation support application. Choose between our heavy du
h"
lift bracket or our medium duty lift bracket. Both brackets are also available f
grout injection. All of our brackets are made from high -tensile strength steel a
comprised of CNC machined parts, ensuring precision and accuracy, In additio
all brackets are robotically welded guaranteeing a quality product every time.
brackets have been field and lab tested and can be powder -coated or galvanize]
amumm
TMG Manufacturing offers several types of foundation support piers, design
I
to be installed directly to load bearing strata. All piers are used in conjuncti
with our lift brackets to stabilize and strengthen existing foundations. All pins a
e*witeer certified
Foundation / Stem Wall
iuide Sleeve
7/22/2021
Kenneth F Wheeler, P.E.
PE4 60417
Cool and Cobb Engineering Co.
203 W. Main St.
Avon Park, FL, 33825
--------UQ -
O
O
i
i
I
2"
7/22/2021
Kenneth F Wheeler, P.E.
PE# 60417
Cool and Cobb Engineering Co.
203 W. Main St.
Avon Park, FL 33825
TMG Manufacturing NAME DATE TITLE:
w rm�m,g om DRAWN LB12 MD —
Name 1-'-2013
55 7 W. Siigh Ave SU Ye 100
ampa.Florida 33634 CHECKED Name 1-1-2.013 STANDARD DUTY ��� KIPS)
',. .:.mot 3, 624 .U0 _..__..... _. 3) 464 2299
(81
ENGAPPR. TMG 2-1-2014 SIZE DWG. NO. REV
TT01 FRANCESUNLESS OTHERWISE SPECIFIED MATERIAL 30-0001
X/XFINISH
Hot Dip Galvanize SCALE: 1:8 'WEIGHT:58.37 SHEET 1 OF 1
5 4 3 2 1
Stable Foundation
Solutions, Inc.
To whom it may concern. I Carl D. King CBC1263287 grant permission to Travis D. King to be my / our
power of attorney to pull or request or pick up any and all building permits for our company Stable
Foundation Solutions, Inc. Under my authority of a building contractor in the State of Florida.
�J)'
Carl D. King
Steven8. Gayheart
Notary Public
Connnnission#OG3S39Q3
EXP.7-11-2O23
Travis D. King
Notary Public - State of Florida
My Comm. Expires Jul 11, 2023
Bonded through National Notary Assn.
9=-,- �
Cool and Cobb Engineering Company
Date: 8/25/2021
Job: Michael Caciog�ao
Location: 5604 18"' St
Zephyrhills, FL 33542
Message: As of this date I have inspected the Installation Log on the above not
project and based on the Installation Log I hereby approve the installation as
being in accordance with the design completed and certified by Cool and Cobb
Engineering Co. for this project. This certification does not address any possibI
sinkhole activity as defined in Florida Statute § 627.706. 1
Sincerely,
812512021
Kenneth F Wheeler, P.E.
State of Florida
Professional Engineer No. 60417
203 W. Main St.
Avon Park, FL 33825
Office: (863) 657-2323
Fax: (863) 657-2324
Email: kengcoolandcobb.corn
Contractor: Stable Foundation Solutions
N
1 •
a
MICHAEL CACIOPPO
560418th STREET ZEPHYRHILLS, FL 33542
SINGLE —STORY CMU HOME ON CONCRETE FOUNDATION WITH A SHINGLE ROOF
(5) MODEL 300 PUSH PIERS THREE CONCRETE CUTS INCLUDED
8/25/2021 Cool and Cobb Engineering Co
KennethF Wheeler. P.E. 203 W. Main St.
PE# 60417 Avon Park, FL 33825
stab 1 c>ura 3 ti arr
1
st'a'llati-o'n• •' TMG Model
No ME 17612
Michael Cadoppo
LOCATION AND DRIVING FORCE - Pressure (PSI)
S11
Ii
•11
.ii
ii
IIi
IIi
ii
ii1
Zi
��
Lift Bracket:r ..
- - • -- �: • ,., rCrAFTMITIMMMaggM,
9/25/2021
Kenneth F Wheeler, P.E.
PE# 604
w
Cool and Cobb Engineering Co.
203 W. Main St.
Avon Park, FL 33825