HomeMy WebLinkAbout21-2628City of Zephyrhilis
5335 Eighth Street
Zephyrhills, FL 33542
Phone: (813) 780-0020
Fax: (813) 780-0021
SEEM=
BGR-002628-2021
Issue Date: 08/24/2021
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
, 55�7
4 fz�
ala��e
0111A 01 S PEfAIT OFFICE[)
.'LERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOK
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
City of Zephyrhills Permit Application
Building Department
Phone Contact for Permitting
104684404
*8444888 0 a No won*" a as
as 6 so
Owner Phone Number
161"INT-T"01M
Fee Simple Titleholder Name
Owner Phone Number
Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS e—l;a -7� 9* LOT #
SUBDIVISION PARCEL I D#
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR'
11 INSTALL
SIGN DEMOLISH
Go
BUILDING SIZE SO FOOTAGE = HEIGHT
41� Hii 444444444�
=BUILDING I VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL AMP SERVICE PROGRESS EN i GY
=PLUMBING
=MECHANICAL
kp VALUATION OF MECHANICAL INSTALLATION e'T
=GAS ROOFING SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
H 1111111 H4++44++H4-H
BUILDER COMPANY FEE CURREN
SIGNATURE REGISTERED
Address License #
ELECTRICIAN COMPANY =/N FEE CURREN
SIGNATURE REGISTERED
Address License #
PLUMBER COMPANY
SIGNATURE REGISTERED FEE CURREN L_y
_LN_j
Address License #
MECHANICAL COMPANY
SIGNATURE I REGISTERED N FEE CURREN
Address License #
OTHER COMPANY
SIGNATURE REGISTERED FEE CURREN Y/N
Address License # LAI
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
144a444:� - -r-rT-r-rT-"-r-1-rUT
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
.. Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing sam4�
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
INSTR#2021169835ORBK10413 PG459 Page 1 of 1
08/11/2021 03:04 PIVI Ropt: 2338099 Rec: 10.00 DS: OM IT: 0.00
Nikki Alvarez -Bowles, Esq., Pasco County Clerk & Comptroller
3ems
-L4
alit W1
Generu! DawtOon of brovsroeog
Owner kftmwb"*r L00001rdtomation #tne Lesmoxftawd ftft
AWAP3011
OM/-
wift ft Stabe d FW49 deSOMW by the owner upon %ftm rodoee or Gum domanwas wded
rl3,i3( F1oIft%SWOAw be Served as Pro by
Xn
k4i .4
Adtfow-
TeMphone May6er d 0900saled Person:
In addition to himseff. 00 owner desourtes of
6 to VOCOM a OW of the Wrote Noft as provided in Secftn 71 3.13(i)(b), Flokfa SW
Talephore, Number of Pereon or EnMy Deetrtaftd by Owner:
EMI deW a' NI d COMMvemeM MW WVM*in Oft MQY not be bOkM ft O"OstiOn Of (XI Old firial payrnam to the
oontracux,, hd wW be one your *om ft dated mcm*V uraw a dWeverd do* is spedfieft
kvftmoot was wwcutod!
rag DAMAW
FAHIM A. :AREZO
id
lor , a Notary Public • State of Florida
o
0
wi Commission # GG 300666
1 202
My Comm. Expires Feb 11, 2023
1 .1 Notary
A"
Bonded through National Notary Assn.
39246 SOUTH AVE ZEPHYRHILLS, FL 33542
813-715-4617
51AH110ENSEA-CECOM
T
SPEChWMG RV METAL ROOF.UVG SYSTEMS
NAME:
Wendy WdhWibou
PHONE: -
813
STREET:
STATE, zip co&-
5127 r Sc
Zepbyrhft
Florida 33542
COWAWREP:
EMAIL
John Cberry 813 949-7594
wend y-etW29@9-m&--
IT IS AGREED:
5 and
-1141 �11V Pm*
'PURCRASER jj
0
PT
Triple Crown fmg,lnc, DATE JRCHASER DATE,
CREEK
TECHNICALI
Tampa,17520 Edinburgh Dr
4
•� r� r wr . • ! 1
Manufacturer: GULF COAST SUPPLY & MANUFACTURING, LLC
14429 SW 2" a Place, Suite G30
Newberry, FL 32669
(352) 498-7652
vv�.€ Ifcca( ur
Manufacturing Locations: Alachua, FL
Sebring, FL
Montgomery, AL
Quality Assurance: Keystone Certifications, Inc. (QUA1324)
Category:
Roofing
RoofingMetal
1504.3
Entity
Report No.
Standard
Year
Force Engineering & Testing (TST5328)
72-0313T-06A-C
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
72-0198T-07A-C
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0033T-05
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0053T-05
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0062T-07A-C
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0062T-07D-F
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0062T-07G-1
UL 580
2006
UL 1897
2012
Farce Engineering & Testing (TST5328)
117-0062T-07J-K
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0065T-07A-C
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0076T-12A
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0089T-05.1
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0089T-05.2
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0102T-05
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0165T-11B
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0238T-09D
FM 4471
1992
Force Engineering & Testing (TST5328)
117-0238T-09E
FM 4471
1992
Force Engineering & Testing (TST5328)
117-0238T-11A
FM 4471
1992
Force Engineering & Testing (TST5328)
117-0248T-07A,B
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0284T-09A
UL 580
2006
UL 1897
2012
GCS20002.1 a FL33818-R1 Page 1 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
CREEK
a
Metal Roofing
TECHNICAL SERVICEs, LLC
Entity
EMgrt No.
Standard
Year
Force Engineering & Testing (TST5328)
117-0285T-09A
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-030IT-10A-C
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0330T-10A-B
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0331 T-08A
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0331 T-08B
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0331T-08D
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0337T-10
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0378T-1 1A
FM 4471
1992
Force Engineering & Testing (TST5328)
117-0378T-1 113
FIVI 4471
1992
Force Engineering & Testing (TST5328)
117-0378T-1 1 C
FM 4471
1992
Force Engineering & Testing (TST5328)
11 7-0407T-09
UL 580
2006
UL 1897
2012
Force Engineering & Testing (TST5328)
117-0407T-09A
UL 580
2006
UL 1897
2012
Intertek- West Palm Beach (an ATI company) (TST1527)
B9000.01-450-18
UL 580
2006
UL 1897
2012
Intertek- West Palm Beach (an ATI company) (TST1527)
C0308.01-450-18
UL 580
2006
UL 1897
2012
Intertek- West Palm Beach (an ATI company) (TST1527)
D0818.01-450-18
UL 580
2006
Intertek- West Palm Beach (an ATI company) (TST1527)
13169101-450-44
UL 580
2006
UL 1897
2012
ASTIVI E 8
Intertek- West Palm Beach (an ATI company) (TST1527)
G7287.01-450-44
UL 580
2006
PRI Construction Materials Technologies (TST5878)
1272T0005
ASTM G 155
2013
PRI Construction Materials Technologies (TST5878)
2292T0001
UL 580
2006
UL1897
2012
PRI Construction Materials Technologies (TST5878)
2292T0002
UL 580
2006
UL 1897
2012
GCS20002.1a FL33818-RI Page 2 of 6
I 11W I 1 1, 1
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
q,pecifiGally addressed herein.
GCS20002,1a FL33818-Rl Page 4 of 6
"duutl tupulL Uutjtj TIQL UAPIQZ55 11*1 1111plij UdtIdfItj, 1115WIldt"'Ifl, Im;*ITj1fIQ(4tou use, *Fwermr ��Ifjttut am.wittezi Im., we
specifically addressed herein.
A
GCS20002.1a FL33818-Rl Page 5 of 6
4,k 9
ir us
specifically addressed herein.
I�=������^��0�� �ULFCQA�T8VPPLY� LLC
���������� Metal Roofing
TECHNICAL SERVoCES,LLC
LIMITATIONS
1� Fire classification isnot within the scope ofthis evaluation.
2� This report ionot for use inthe HVHZ.
3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4. Roof slope shall bminaccordance with F8CSection 15O7.4.2.
5� Reroofing shall beinaccordance with FBCSection 1511. Recovery versus replacement shall beevaluated
inaccordance with FBCSection 1511.3.
6� Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. VVhenm discrepancies exist between theme suurcen, the more restrictive
and FBCcompliant installation detail shall prevail.
7. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 81 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R, Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7 th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
41
No 74021
CC
0.
����� ��7�
����x.��.,�
J'a
��.����.�� L� `�~~��~/�~�~��.~~ v '
_�u�«���� ��_� ��
ZanharyFi Priest, P.E.
Fbr�mReQ��*UonNo. 74O21
Omeniza�onNo. ANE9641
~�wouxounw�~' ~---
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest many company manufacturing mdistributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. poee. P.E. does not have, nor will mcquina, efinw^oia| interest in any company manufacturing or distributing products
under this evaluation.
Zachary R, Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
1) APPENDIX A— Installation (5 pages)
2) APPENDIX B — Approved Roof Systems (7 page
3) APPENDIX C — Design Wind Loads (4 pages) I
8CS20002Aa PL3388fn Page 0vfO
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
CREEK Metal Roofing
I TECHNICAL. SERVICES, LLB APPENDIX A
INSTALLATION
Note - Refer to the APPRovED ROOF SYSTEMS Section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
component Product Installation Detail
#9-15 HWH wood screw
with sealing washer
#9-15 HWH WoodZAC
screw
#10-12 Pancake Type A Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion
screw resistant in accordance with FBC section 1507.4.4.
Fasteners #12-11 Pancake Type A
screw
#12-8 HWH Woodgrip
XG screw with sealing
washer
1/4-14 HWH ZAC Impax Installed at panel side lap; Shall be corrosion resistant in accordance with FBC
Lap screw section 1507.4.4.
24 ga, in -seam clip
Gulf-ok Clip
Clips
18 ga. in -seam clip
Fixed Clip
GCS20002.1a FL33818-RI Page I of 5
specifically addressed herein.
CREEK
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
_Component Product
Installation Detail
U8
4-1W
NC-33003-3 Sliding Clip
1/2"
Clips (Cont'd)
1.
22 ga. top; 16 ga. base; in -seam clip
'18
1500SC Sliding Clip
J
L_J U L.E
i t
J
40 A
Sealants
I-
TiteBond Weathermaster
Metal Roof Sealant
Shall be applied in 1/4% 5/16" continuous beads on the male rib along the seam
Nomenclature Attachment
Gulkok Type I (1) #10-12 X 1' TYPE A PANCAKE----,/
1A* #43 STAIWESS
GULF LOKIPANEL STEEL RVIET @ W
((WEPLAP SIDE, 0 C'
GulfLok Overtap GOLF LOK PAWL
Ile (UNDERLAP SADE)c
RANCUP $CREW
GCS20002.1a FL33818-R1 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3, The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein,
CREEK
TECHNICAL SERVICES, LLC
GuIfLok Type 2
I
g Details
Attachment
GuIfLok"* CLIP 24 GA.
Hsi 11 ! 11 NEW'S wiilzolrklulzjuj��
18 Ga, Fixed Clip
GulfSeam Type 1
(2) #10-12 Pancake Type A Per lip.---
MegaLoc Type I
C\j
T77-�33003 SLIDING CLIP
(2) #10-12 x I" per Clip-
VersaLoo Type I
500SC SLIDING CUP
(2) # 12-11 x 1" Panhead per Clip
5 x 1-1/2" HWH w/Sealing Washer
5V Type 1
1211 1211 --------------
At Panel Lap
'--(1) #9-15 x 1-1/2" HWH w/Sealing Washer
5V Type 2
211-�-9.5"---i2�--9.5" "2111
GCS20002.1a FL33818-RI Pa2e 3 of 5
1 M, b"Ap 11611
OrdlUdWOUI-M�"IL VACZ, 110L eAI!Ifez�"� 111911
specifica Ily addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
CREEK Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX A
Fastening Details
Nomenclature Attachment
5V Type 3
At Panel Lap
L(J) #9-15 x 1-1/2" HWH w/Sealing Washer
At Panel @ O
Lap---/
#1/4-14 x 7/81' Lap Screw 240 .C. Max.
71
12" ---- ----- 12" -
GulfPBR Type I
_(1) 09-15
#1/4-14 x 71W Lap Screw @ 24" O.C, Max,
5t' 711 - ------ 7" 511 - 7"
GutfPBR Type 2 11
#9-15 x 1-1/2"
90 90
At Panel Lap
GulfRib Type 1 11 1� T_ _---
Z(1) #9-15 x 1-1/2w/' Sealer Washer
6 5"
GulfRib Type 2
�(I) #9-15 x 1-1/2"w/Seater Washer
GCS20002.1a FL33818-RI Page 4 of 5
• ly report does nop t express nor im-- fanty, Instaltaurill, W5111111011iRR MR, ff amel xiulvu
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
CREEK Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX A
Fastening Retails
Nomenclature Attachment
------- ---- — ------ 1-90 ------------- C11I--------
GulfRib Type 3
At Panel Lap" ---7
W 99 90—
-6.5" 4_'Z"
GuIfRib Type 4
J;'� W.
(1) #12-8 x 1-1/2"WoodGrip JIG W/Seater Washer
At Panel Lap-7
.811 ---� 5.3 11
GuffWave Type I
#9-15 x 1-1/2" HWH w/Sealing Washer
GCS20002.1a FL33818-R1 Page 5 of 5
lowl. f9mm I 'i I I I i- I W. 1,11
gpecifically addressed herein.
CREEK
TECHNICAL, SERVICES, LLC
APPROVED ROOF SYSTEMS
roil
Metal Roofing
The following notes shall be observed when using the assembly tables below.
1 . Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1504.9.
Z Refer to UmITATIONs and sections of this evaluation when using the table(s) below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system.
5. The panel thickness or gauge is the minimum allowable.
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR)
conforming to ANSI/SDI-RD1.0
T Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15132-inch thick APA Span -Rated plywood
sheathing at maximum 24-inch span.
Robers and Definitions
LOK4V#
GulfLok over Wood Deck (New or Existing)
SEA -W
GulfSeam over Wood Deck (New or Existing)
MegaLoc over Wood Deck (New or Existing)
1.5" VersaLoc over Wood Deck (new or Existing)
5V Crimp over Wood Deck (New or Ex!��
PBR-W#
GuIfPBR over Wood Deck (New or Existing)
LRIB-Vl#
GulfRib over Wood Deck (New or Existing)
_AAVE-1JVk
GuIlWave over Wood Deck (New or Existing)
System
No.
Deck
Fire Barrier
Undedayment
Roof Panel
Panel Attachment
MDP
(Psf)
LOK-W-1
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
26 ga., Grade 80 GulfLok
GuIfLok Type I attachment #10-12 x 11,
-63.5
B-C plywood
or insulation
Max. 16-inch coverage
Pancake Type A p screws spaced 5-3/16 in. o.c
LOK-W-2
Min, 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 0.032" Al Gulf-ok
GulfLok Type I attachment with #10-12 x I"
-65.5
B-C plywood
or insulation
Max. 16-inch coverage
Pancake Type A screws spaced 5-3/16 in. o,c.
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
24 ga. GulfLok
GulfLok Type I attachment with #10-12 x 1"LOK-W-3
-81.75
B-C plywood
or insulation
Max. 16-inch coverage
Pancake Type A screws spaced 10-1/4 in. o.c.
OPTIONAL
GulfLok Type I attachment with #10-12 x 1"
LOK-W-
Min. 15/32
Approved fire barrier
As required per FBC
Min. 0.040"AJ Gulf
Pancake Type A screws spaced 6 in. o.c.
-93.5
CDX plywood
or insulation
Max. 16-inch coverage
Female leg snap -fit to male Iegg with
GulfLok Overlap
GCS20002.1a
FL33818-RI
Page 1 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, orothel
product attributes that are not specifically addressed herein,
GULF COAST SUPPLY & MANUFACTURING, LLC
CREEK Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX B
— -------- ---- — --- --- ...
L Approved Systems for GuffLok over Wood Declk (Now or Existing)
System
No.
Fire Barrier
Underlayment
Roof Panel
Panel Attachment
WL--
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBCIll
24 ga. Gulfl-ok
GulfLok Type 1 attachment with #10- 12 x 1
N
B-C plywood
or insulation I
Max. 16-inch coverage
I
Pancake Type A screws spaced 5-1/8
OPTIONAL
I
G ul/Lok Tvae I attachment with 10%�-12x
&
Min. 15/32
Approved fire barrie
11
As required per
Min. 0.032'AJ Gulfi-ok
Pancake Type A screws spaced 5-31Fin.xo.c.
B-C od—
plywo,
or insulation
j!
Max. 16-inch coverage
Titebond Weathermaster Metal Roof Sealant
applied to male rib.
OPTIONAL
Gulfl-ok TvDe 1 attachment with #10-
Min. 15/32
Approved fire barrier
As required per FBC
Min. 26 ga. Gulfi-ok
Pancake Type A screws spaced
CDX pf
or insulation
Max. 16-inch coverage
Titebond Weathermaster Metal Roof Sealant
applied to male rib.
Min. 15/34
OPTIONAL�III
ga., Grade 80 Gulfi-ok
26 ■
Guftok Type 2 attachment with
"
11
B-C plywood
Approved fire barrier
As required per FBC
Max. 16-inch coverage 1
#10-12 x 1 Pancake Type A screws through
,M
I
or insulation
c lip and pace5-3 sd G. 6 ioc
n.•.
iw� lw�
r_1 "M ".
System
No
Fire Barrier
Underlavment
Rof
oPanel
APanel ttachment !Ekup
M-
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. GuIfSeam I
GuIfSeam Type I attachment i
CDX plywood--
or insulation
Max. 16-inch coverage
with clips spaced
Min. 15/32
OPTIONAL
Approved fire barrier I
As required per FBC
Min. 0.032" At GulfSeam
GulfSeam Type I attachment
COX plywood
or insulation
Max. 16-inch coverage
with stainless steel clips spaced 18 in. o.c.
il
n. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min 24 ga. GulfSeam
GulfSeam Type I attachment
BMC plywood
or insulation
Max' 18-inch coverage
with clips spaced 24
—Am
JF�Min.
1E132
OPTIONAL
A roved fire barrier
PP
As required per FBC
Min. 26 ga. GulfSeam
GulfSeam Type I attachment
CDX plywood::::::j,,
or insulation
Max. 16-inch coverage
with clips spaced 6 in. o.c.
Min. 15/32
OPTIONALII
rovedfirebarrieAsrequired
perFBColCDXplywoodoon
Min. 0.032"AJ GulfSeam
GuffSeam Type I attac�[iient
a6ccoverage
wsanesssteepsspd 6 in. o.c.
GCS20002.1a --------FL338-18-RI --- Page 2 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, orother
product attributes that are not specifically addressed herein.
CREEK
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal
Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for GuffSeam over Wood Dock (New or Existing)
System
No.
Deck
Fire Barrier
Undedayment
Roof Panel
Panel Attachment
MDP
(psf)
SEAM-W-3
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 0.032 AJ GulfSeam
GulfSeam Type I attachment
-86
CDX plywood
or insulation
Max. 18-inch coverage
with stainless steel clips spaced 18 in. o.c.
Min. 1x4 No. 2
SYP wood
SEAM-W-4
purlins spaced
18 in. o.c.
OPTIONAL
Approved fire barrier
As required per FBC
Min. 24 ga. GulfSeam
GulfSearn Type I attachment with clips spaced
-93.5
over
or insulation
Max. 16-inch coverage
18 in. o.c. over wood purlins
Min. 15132
1
B-C plywood
SEAM-W-5
Min 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 24 ga. GulfSearn
GuffSeam Type I attachment
-108.5
B-C Plywood
or insulation
Max. 18-inch coverage
with clips spaced 12 in. o.c.
Min. 1x4 No. 2
SYP wood
SEAM-W-6
purlins spaced
24 in. o.c.
OPTIONAL
Approved fire barrier
As required per FBC
Min 24 ga. GulfSeam
GuJfSeam Type 1 attachment with clips spaced
-114.25
over
or insulation
Max'. 18-inch coverage
24 in. o.c. over wood purlins
Min. 15/32
CDX plywood
SEAM-W-7
Min 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 0.032" At GulfSeam
GulfSearn Type I attachment
-138.5
CDX plywood
or insulation
Max, 16-inch coverage
with stainless steel clips spaced 6 in. o.c.
Min. 1x4 No. 2
SYP wood
SEAM-W-8
purlins spaced
12 in. o.c.
OPTIONAL
Approved fire barrier
As required per FBC
Min 24 ga. GulfSeam
GulfSeam Type I attachment with clips spaced
-159.25
over
or insulation
Max. 18-inch coverage
12 in. o.c. over wood purlins
Min. 15/32
CDX plywood
Approved Systems for Megal-oc over Wood Dock (New or Existing)
System
No.
Deck
Fire Barrier
Underlayment
Roof Panel
Panel Attachment
MDP
(psi
GCS20002.1 a --- --------FL33818-RI Page 3 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVIcEs, LLC
APPENDIX B
Approved Systems for Megad oc over Wood Deck (New or Existing)
System Deck
No.
Fire Barrier Underlayment
Roof Panel
Panel Attachment
MDP
(Psf)
Min 15/32
MEGA-W-1
OPTIONAL
Approved fire barrier As required per FBC
Min. 24 ga. Megal-oc
MegaLocType I attachment
-71
B-C plywood
or insulation
Max. 18-inch coverage
with clips spaced 24 in. ox.
ME-:GA-W:-2]
Min. 15/32
OPTIONAL
Approved fire barrier As required per FBC
Min. 24 ga. MegaLoc
I I
MegaLocType I attachment
-108.5
I
B-C plywood
or insulation
Max. 18-inch coverage
with clips spaced 12 in. O.C.
FL33818-Rl
SIMI
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
GULF COAST SUPPLY & MANUFACTURING, LLC
Roofing
Metal
TECHNICAL SERVIcEs, LLC
APPENDIX B
Approved Systems for Versal-oc over Wood Deck (New or Existing)
System Deck
Fire Barrier Underlayment
Roof Panel
Panel Attachment
MDP
(psf)
No.
Min. 15/32
VL-W-1 B-C plywood
OPTIONAL
Approved fire barrier As required per FBC
Min. 24 ga. Versal-oc
Max. 16-inch coverage
VersaLoc Type I attachment
with clips spaced 24 in. o.c,
-59.75
or insulation
Min. 15/32
VL-W-2
I
OPTIONAL
Approved fire barrier As required per FBC
Min. 24 ga. Versal-oc
VersaLoc Type I attachment
-1215
B-C plywood
I
or insulation I
Max. 16-inch coverage
with clips spaced 6 in, O.C.
System
Deck
Fire Barrier/
Undedayment
Roof Panel
Panel Attachment
MDP
(Psf)
No.
Insulation
5V-W1
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. 5V Crimp
5V Crimp Type 3 attachment with #9-15 HWH wood
-94.25
B-C plywood
or insulation
24-inch coverage
screws with sealing washers spaced 16 in. o.c.
5V-W2
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 0.032" Al or
Min. 26 ga. 5V Crimp
5V Crimp Type I attachment with #9-15 HWH wood
screws with sealing washers spaced 12 in. o.c.
10&5
B-C plywood
or insulation
24-inch coverage
5V-W3
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. 5V Crimp
5V Crimp Type 2 attachment with #9-15 HWH wood
-131
B-C plywood
or insulation
24-inch coverage
screws with sealing washers spaced 16 in. o.c.
E-WL4
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. 5V Crimp
5V Crimp Type I attachment with
#9-15 HWH wood screws with sealing washers spaced 6
-156.5
B-C plywood
or insulation
24-inch coverage
I
in. o.c.
GCS20002.1a FL33818-RI Page 5 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
CREEK Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX B
Approved Systems for GulfPBR over Wood Deck (New or Existing)
System
Deck
Fire Barrier/
Underlaye mnt
Roof Panel
MDP
Panel Attachment
No.
Insulation
(psf)
OPTIONAL
GulfPBR Type I attachment with #9-15 15 HWH WoodZAC
PBR-W-1
Min. 15/32
Approved fire barrier
As required per FBC
Min, 26 ga. GuIfPBR
screws spaced 24 in. o.c. -60.5
B-C plywood
or insulation
36-inch coverage
Laps fastened with 1/4-14 x 7/8" HWH ZAC Impax: Lap
screws spaced 24 in. o.c.
Min. I x4 No. 2
SYP wood
purfins spaced
OPTIONAL
GulfPBR Type I attachment with #9-15 HWH WoodZAC
PBR-W-2
24 in. o.c.
Approved fire barrier
As required per FBC
Min. 26 ga. GulfPBR
screws spaced 24 in. o.c. into wood pudins
-Ift5
over
or insulation
36-inch coverage
Laps fastened with 114-14 x 7/8 ZAC Impax Lap screws
Min. 15132
spaced 24 in. o.c.
I B-C plywood
Min. 1x4 No. 2
SYP wood
purfins spaced
OPTIONAL
GulfPBR Type 2 attachment with #9-15 15 HWH
PBR-W-3
12 in. o.c.
Approved fire barrier
As required per FBC
Min. 26 ga. GuIfPBR
WoodZAC screws spaced 12 in. o.c. into wood purlins
-151J5
over
or insulation
36-inch coverage
Laps fastened with 1/4-14 x 7/8" HWH ZAC Impax Lap
Min. 15/32
screws spaced 24 in. o.c.
1 B-s plywood
OPTIONAL
GulfPBR Type 2 attachment with #9-15 HWH WoodZAC
PBR-W-4
Min. 15/32
Approved fire barrier
As required per FBC
Min. 26 ga. GuIfPBR
screws spaced 12 in. o.c. -154J5
B-C plywood
or insulation
36-inch coverage
Laps fastened with 1/4-14 x 7/8" HWH ZAC Impax Lap
screws spaced 24 in. o.c.
System
Deck
Fire Barrier/ Underlayment
Roof Panel
Panel Attachment
MDP
No.
Insulation
(Psf)
RIB-W-1
Min. 7/16 OSS
OPTIONAL
Approved fire barrier As required per FBC
Min. 29 ga. GulfRib
GulfRib Type 4 attachment with #12-8 HWH Woodgrip KG
-22.66
or insulation
36-inch coverage
wood screws with sealing washers spaced 24 in. o.c.
RIB-W-2
Min 15/32
OPTIONAL
Approved fire barrier As required per FBC
Min. 29 ga. GulfRib
GuJfRib Type 3 attachment with #9-15 HWH wood screws
-56
I
CDX'Plywood
I
or insulation
36-inch coverage
with sealing washers spaced 24 in, o.c.
I
I I
GCS20002.1 a FL33818-Rl Page 6 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES,
LLC
APPENDIX B
Approved Systems for GulfRlb over Wood Deck (New" or Existing)
System
Deck
Fire Barrier/
Insulation
Undedayment
Roof Panel
Panel Attachment
MDP
(Psf)
No.
RIB-W-3
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 29 ga. GulfRib
GulfRib Type 1 attachment with # with #9-15 HWH
-71.75
B-C plywood
or insulation
36-inch coverage
WoodZAC screws spaced 24 in. o.c
Min. 1x4 No. 2
SYP wood
purlins spaced
OPTIONAL
29 GulfRib
Min. ga.
GulfRib Type I attachment with #9-15 x 1 1/2" HWH wood
RIB-W4
24 in. o.c.
Approved fire barrier
As required per FBC
36-Inch coverage
screws with sealing washers spaced 24 in. o.c.
-76.75
over
or insulation
into wood purlins
Min. 15132
B-C plywood
Min. 1x4 No. 2
SYP wood
purlins spaced
OPTIONAL
Min. 29 ga. GulfRib
GuIfRib Type 1 attachment with #9-15 x 1 1/2" HWH wood
RIB-W-5
24 in. o.c.
Approved fire barrier
As required per FBC
36-inch coverage
screws with sealing washers spaced 24 in. o.c.
-101
or insulation
into wood purlinsover
Min. 7/16 OSB
RIB-W-6
Min. 15132
OPTIONAL
Approved fire barrier
As required per FBC
Min, 29 ga. GulfRib
GulfRib Type 3 attachment with #9-15 HWH wood screws
-101
CDX plywood
or insulation
36-inch coverage
with sealing washers spaced 12 in. o.c.
Min. 1x4 No. 2
SYP wood
RIB-W-7
purlins spaced
24 in. o.c.
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. GulfRib
Gulfft Type I attachment with #9-15 HWH WoodZAC
-106.75
36-inch coverage
screws spaced 24 in. ox, into wood purlins
over
or insulation
Min, 15/32
B-C plywood
RIB-W-8
Min. 7/16 OSB
OPTIONAL
Approved fire barrier
As required per FBC
Min. 29 ga. GutfRib
GuffRib Type 4 attachment with #12-8 HWH Woodgrip XG
-116-0]
or insulation
36-Inch coverage
wood screws with sealing washers spaced 6 in. o.c.
GCS20002.1a FL33818-RI Paqe 7 of 41
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3, The manufacturer shall notify CREEK Technical Services, LLC of any product changes
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, orot
product attributes that are not specifically ddressed herein, I
a
GULF COAST SUPPLY & MANUFACTURING, LLC
CREEK Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX B
Approved Systems for GulfRib over Wood Deck (Now or Existing)
System Deck
Fire Barrier/
Insulation
Underlayment
Roof Panel
Panel Attachment DP
(Psf)
No.
Min, I x4 No. 2
SYP wood
purlins spaced
OPTIONAL
Min. 29 ga. GulfRib
GulfRib Type 2 attachment with #9-15 x 1 1/2" HWH wood
RIB-W-9 24 in. o.c.
Approved fire barrier
As required per FBC
36-inch coverage
screws with sealing washers spaced 24 in, o.c. -123.5
over
or insulation
into wood purlins
Min. 15/32
B-C plywood
Min 15/32
RIB-W-10
OPTIONAL
Approved fire barrier
As required per FBC
Min. 29 ga. GulfRib
GulfRib Type 2 attachment with #9-15 HWH wood screws
-14&0
B-C plywood
or insulation
36-inch coverage
with sealing washers spaced 12 in. o.c.
Min 15/32
RIB-W-1 1
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. GulfRib
GuIfRib Type 2 attachment with #9-15 HWH WoodZAC
-15925
B-C plywood
or insulation
36-inch coverage
screws spaced 12 in. o.c.
Min. I x4 No, 2
SYP wood
purlins spaced
RIB-W-12 12 in. o.c.
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. GulfRib
GuffRib Type I attachment with #9-15 HWH WoodZAC
-164.25
over
or insulation
36-inch coverage
screws spaced 12 in. o.c. into wood purlins
Min. 15/32
B-C plywood I
WC101777M."O"T. ".-IR
System Fire Barrier/ 1 11 #1.
Underlayment Roof Panel Panel Attachment
No. Insulation
OPTIONAL IfVVave GulfWave Type I attachment with
Min. 5132 1 Min. 26 ga. Gu
j Approved fire As required per FBC #9-15 HWH wood screws with sealing washers
B-C plywood i' barrier or insulation 29-inch coverage spaced 24 in. o,c.
GCS20002, I a FL33818-Rl Page 8 of
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes'
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,
product attributes that are not specifically addressed herein. I
CREEK
TECHNICAL SERVICES, LLC
DESIGN WIND LOADS
Metal Roofing
The following tables provide design wind loads for components and cladding in accordance with Section1609 of the FBC and ASCE 7-18under the following
provisions:
1� Wind speeds for risk category 1, 11, 111, and IV buildings shall be as defined in Section 1609 of the FBC.
2. Exposure B.C.and Dshall beoadefined insection 18O9ofthe FBC.
1 Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based onaneffective wind area of1Q-ft2orless.
5. Topographic factors such aeescarpments orhills have been excluded from the analysis
S. Overhangs have been excluded from the analysis.
[ Wind directionality factor, Ko=O.85
8. V.1t is shown in the tables below. Design wind loads are calculated using Vasd = V,,itA.6 per 1609.3.1.
9. Zone 2iainclusive ofZone 2e.Zone 2o'and Zone 2r
1D. Zone 3iminclusive ofZone 3eand Zone 3r
11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
12, Zones 1.2.and 3shall bndefined aashown below. Dimension "a" shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever
is smaller, but not less than either 4% of the least horizontal dimension or 3ft
Gable Hip
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or ot]
product attributes that are not specifically addressed herein,
CREEK
TECHNICAL SERVICES, LLC
GILF COAS I
Metal RooflnS
GCS20002.1a FL33818-RI Page 2 of 4
evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes a
#,uality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, orothW
product attributes that are not specifically addressed herein, I
CREEK
TECHNICAL SERVICES, LLC
G#LF COAST SIPPLY & ffAlUFACTIRING, LLC
Metal Roofing
GCS200021a FL33818-RI Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3, The manufacturer shall notify CREEK Technical Services, LLC of any product changes
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or ot
product attributes that are not specifically addressed herein. I
CREEK
TECHNICAL SERVICES, LLC
GULF COAST SUPPLT& W%111FACT#Rli1G, LLC
Metal Roofing
GCS20002.1a FL33818-RI Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-1 The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, orother
product attributes that are not specifically addressed herein,